Loading...
PGA West Signature - The Haciendas TR 36537 BTCP 2016-0001 Title 24Title 24 Energy Report The Haciendas at PGA West La Quinta Climate Zone #15 2013 Building Energy Efficiency Standards HEG Project No.: 14024 Revised Report California West Construction Bassenian Lagoni Architects Heritage Energy Group, LLC August 20, 2014 Title 24 Energy Calculations Tel: (949) 789-7221 / Fax: (949) 789-7222 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P1 U.xml CF1 R-PRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Plan 1 - Haciendas 02 Calculation Description Title 24 Analysis 03 Project Location 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 1941 15 Number of Zones 1 16 Slab Area (FTZ) 1941 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FTZ) NA 21 Glazing Percentage (°/a) 23.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P1 U.xml CFI R-PRF-01 Page 2of8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.70 2.44 -0.74 43.5% Space Cooling 114.54 113.16 1.38 1.2% IAQ Ventilation 1.31 1.31 0.00 0.0% Water Heating 13.44 6.49 6.95 51.7% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 130.99 123.40 7.59 5.8% Space Heating 1.70 2.71 -1.01 -59.4% Space Cooling 114.54 107.45 7.09 6.2% IAQ Ventilation 1.31 1.31 0.00 0.0% Water Heating 13.44 6.49 6.95 51.7% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 130.99 117.96 13.03 9.9% Space Heating 1.70 2.88 -1.18 -69.4% Space Cooling 114.54 ;,p;= 112.15 2.39 2.1% IAQ Ventilation 1.31 P .! 1.31 0.00 0.0% Water Heating 13.44 ;; r+4 .6.49 6.95 51.7% PV Credit ---- 0.00 0.00 ---- South Facing - TOTAL 130.99 122.83 8.16 6.2% Space Heating 1.70 2.04 -0.34 -20.0% Space Cooling 114.54 104.69 9.85 8.6% IAQ Ventilation 1.31 1.31 0.00 0.0% Water Heating 13.44 6.49 6.95 51.7% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 130.99 114.53 16.46 12.6% Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Page 3 of 8 Calculation Description: Title 24 Analysis Input File Name: 14024P1 U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Non-standard roof reflectance • Window overhangs and/or fins PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below reclure field verification by a certified HERS Rater. Check the individual building component sections below for any required HERS verification requirements. BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1- Haciendas 1941 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 1941 10 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ftZ) Tilt(deg) Front Wall Zone 1 R-19 Wall 0 Front 222 15 90 Left Wall Zone 1 R-19 Wall 90 Left 606 108.5 90 Rear Wall Zone 1 R-19 Wall 180 Back 369 210.5 90 Right Wall Zone 1 R-19 Wall 270 Right 808 128 90 garage wall Zone 1 R-19 Wall NSG 0 Front 300 0 90 Roof Zone 1 R-38 Roof Attic RB 1941 Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024131 U.xml CF1 R-PRF-01 Page 4of8 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multipli er Area (ft2) U- factor SHG C Exterior Shading 3050 Window Front Wall (Front-0) ---- ---- 1 15.0 0.34 0.23 3080 Window Left Wall (Left-90) ---- ---- 1 24.0 0.35 0.25 4050-2 Window Left Wall (Left-90) ---- ---- 1 40.0 0.34 0.23 4020=2 Window Left Wall (Left-90) ---- ---- 1 16.0 0.34 0.23 3040-2 Window Left Wall (Left-90) ---- ---- 1 24.0 0.34 0.23 3016 Window Left Wall (Left-90) ---- ---- 1 4.5 0.34 0.23 3050-3 Window Rear Wall (Back-180) ---- ---- 1 45.0 0.34 0.23 3016-3 Window Rear Wall (Back-180) ---- ---- 1 13.5 0.34 0.23 16080 dr Window Rear Wall (Back-180) 16.0 8.0 1 128.0 0.36 0.22 3020-4 Window Rear Wall (Back-180) ---- ---- 1 24.0 0.34 0.23 3050-2 Window Right Wall (Right-270) ---- ---- 1 30.0 0.34 0.23 3016-2 Window Right Wall (Right-270) ---- 1 9.0 0.34 0.23 4050 Window Right Wall (Right-270) ---- ---- 1 20.0 0.34 0.23 2040 Window Right Wall (Right-270) ---- ---- 1 8.0 0.34 0.23 5050 Window Right Wall (Right-270) ---- ---- 1 25.0 0.34 0.23 5020 Window Right Wall (Right-270) ---- ---- 1 10.0 0.34 0.23 2030 Window Right Wall (Right-270) ---- 1 6.0 0.34 0.23 2050-2 Window Right Wall (Right-270) ---- 1 20.0 0.34 0.23 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wall 28.0 0.50 Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P1 U.xml CFI R-PRF-01 Page 5 of 8 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Sot Up 16080 dr 11 0.1 1 20 1 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Inside Finish: Gypsum Board Sheathing/insulation: - no sheathinglnsul. - Cavity: R 19 Sheathing/Insulation: - no sheathinglnsul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 Sheathinglnsulation - no sheathinglnsul. - R-38 Roof Attic RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinglnsul. - Cavity: R 19 Sheathing/Insulation: - no sheathinglnsul. - R-19 Wall NSG Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter Ift) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab Zone 1 1941 229 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P1 U.xml CFI R-PRF-01 Page 6of8 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Systeml Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 1941 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024131 U.xml CFI R-PRF-01 Page 7 of 8 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge HVAC Systeml SCSysRpt 1 Required 350 --- 15.0 Verified HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Sealed and tested 6 Attic Attic None Air Distribution attic System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 57 Exhaust 0 Required Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08:47:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 1 - Haciendas Calculation Date/Time: 22:45, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P1 U.xml CF1 R-PRF-01 Page 8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2014-08-20 00.-58:13 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents. worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: ResponsibleDesigner Signature: Jen Wipper Company: Date Signed: California West Communities 2014-08-20 08:47:30 Address: License: 5927 Priestly Drive, Suite 103 927267 City/State/Zip: Phone: Carlsbad, CA 92008 760 918 2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-NO06262OB-000000000-0000 Registration Date/Time: 2014-08-20 08AT30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T22:55:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date[Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CF1 R-PRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Plan 2 - Haciendas 02 Calculation Description Title 24 Analysis 03 Project Location 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FTZ) 2042 15 Number of Zones 1 16 Slab Area (FT2) 2042 17 Number of Stories 1 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FTZ) NA 21 Glazing Percentage (%) 26.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 214-N00626218-000000000-0000 Registration Date/Time: 2014-08-20 08:48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CF1 R-PRF-01 Page 2 of 8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.56 2.45 -0.89 -57.1% Space Cooling 112.53 113.90 -1.37 -1.2% IAQ Ventilation 1.10 1.10 0.00 0.0% Water Heating 12.96 6.34 6.62 51.1% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 128.15 123.79 4.36 3.4% Space Heating 1.56 3.09 -1.53 -98.1% Space Cooling 112.53 106.60 5.93 5.3% IAQ Ventilation 1.10 1.10 0.00 0.0% Water Heating 12.96 6.34 6.62 51.1% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 128.15 117.13 11.02 8.6% Space Heating 1.56 2.79 -1.23 -78.8% Space Cooling 112.53 111.49 1.04 0.9% IAQ Ventilation 1.10 1.10 0.00 0.0% Water Heating 12.96 6.34 6.62 51.1% PV Credit ---- 0.00 0.00 ---- South Facing - TOTAL 128.15 121.72 6.43 5.0% Space Heating 1.56 1.93 -0.37 -23.7% Space Coaling 112.53 106.61 5.92 5.3% IAQ Ventilation 1.10 1.10 0.00 0.0% Water Heating 12.96 6.34 6.62 51.1% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 128.15 115.98 12.17 9.5% Registration Number: 214-No062621B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Non-standard roof reflectance • Window overhangs and/or fins CF1 R-PRF-01 Page 3 of 8 PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below requre field verification by a certified HERS Rater. Check the individual building component sections below for any required HERS verification requirements. BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2- Haciendas 2042 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC Systems 2042 10.1 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window Area (ft2) Tilt(deg) Front Wall Zone 1 R-19 Wall 0 Front 182 48 90 Left Wall Zone 1 R-19 Wall 90 Left 525 141 90 Rear Wall Zone 1 R-19 Wall 180 Back 354 180 90 Right Wall Zone 1 R-19 Wall 270 Right 848 175.5 90 garage wall Zone 1 R-19 Wall 0 Front 210 0 90 garage wa112 Zone 1 R-19 Wall 90 Left 320 0 90 Roof Zone 1 R-38 Roof Attic RB 2042 Registration Number: 214-N0062621B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CFI R-PRF-01 Page 4 of 8 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multipli er Area (ft) U- factor SHG C Exterior Shading 2060-3 Window Front Wall (Front-0) ---- ---- 1 36.0 0.34 0.23 2020-3 Window Front Wall (Front-0) ---- ---- 1 12.0 0.34 0.23 12080 Window Left Wall (Left-90) 12.0 8.0 1 96.0 0.36 0.22 2050-2 Window Left Wall (Left-90) 5.0 5.0 0.8 20.0 0.34 0.23 5050 Window Left Wall (Left-90) ---- ---- 1 25.0 0.34 0.23 3060-2 Window Rear Wall (Back-180) ---- ---- 1 36.0 0.34 0.23 6060/6030/3030-2 Window Rear Wall (Back-180) 3.0 3.0 8 72.0 0.34 0.23 9080 Window Rear Wall (Back-180) 9.0 8.0 1 72.0 0.36 0.22 3060-4 Window Right Wall (Right-270) - ---- 1 72.0 0.34 0.23 3030-2 Window Right Wall (Right-270) ---- ---- 1 18.0 0.34 0.23 3050-2 Window Right Wall (Right-270) ---- ---- 1 30.0 0.34 0.23 50502 Window Right Wall (Right-270) ---- ---- 1 25.0 0.34 0.23 5020 Window Right Wall (Right-270) ---- ---- 1 10.0 0.34 0.23 2040 Window Right Wall (Right-270) ---- ---- 1 8.0 0.34 0.23 2650 Window Right Wall (Right-270) ---- ---- 1 12.5 0.34 0.23 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wall 28.0 0.50 Registration Number: 214-No062621B-000000000-0000 Registration Date/Time: 2014-08-2008:48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CFI R-PRF-01 Page 5of8 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 12080 12 1 12 10 1 0 0 0 0 0 0 0 0 2050-2 2 2 2 2 0 0 0 0 0 0 0 0 0 6060/6030/3030-2 2 2 2 2 0 0 0 0 0 0 0 0 0 9080 12 1 12 10 1 0 0 0 0 0 0 1 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck. Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinglinsul. - Cavity: R 19 Sheathing/Insulation: - no sheathingfinsul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 Sheathinglnsulation - no sheathingfinsul. - R-38 Roof Attic RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Inside Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab Zone 1 2042 220 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required Registration Number: 214-N0062621B-000000000-0000 Registration Date/Time: 2014-08-20 08*48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CF1 R-PRF-01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Systeml Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2042 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool Registration Number: 214-N0082821B-000000000-0000 Registration Date/Time: 2014-08-2008:48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CF1 R-PRF-01 Page 7 of 8 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge HVAC Systeml SCSysRpt 1 Required 350 --- 15.0 Verified HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Sealed and tested 6 Attic Attic None Air Distribution attic System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 50 Exhaust 0 Required Registration Number: 214-N0062621B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:10 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2 - Haciendas Calculation Date/Time: 23:01, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml CF1 R-PRF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Q4-5iu�ad- Rudy Sains Company: Signature Date: Heritage Energy Group 2014-08-20 00:59:30 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Jen Wipper Company: Date Signed: California West Communities 2014-08-20 08:48:10 Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760 918 2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-No062621B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:10 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:09:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CFI R-PRF-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name Plan 3 02 Calculation Description Title 24 Analysis 03 Project Location 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2423 15 Number of Zones 1 16 Slab Area (FT2) 1941 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 j Glazing Percentage (%) 24.1 % COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CFI R-PRF-01 Page 2 of 10 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 3.32 4.44 -1.12 -33.7% Space Cooling 119.48 121.51 -2.03 -1.7% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.54 5.90 5.64 48.9% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 135.34 132.85 2.49 1.8% Space Heating 3.32 4.33 -1.01 -30.4% Space Cooling 119.48 121.06 -1.58 -1.3% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.54 5.90 5.64 48.9% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 135.34 132.29 3.05 2.3% Space Heating 3.32 4.18 -0.86 -25.9% Space Cooling 119.48 122.48 -3.00 -2.5% IAQ Ventilation 1.00 1.00 0.00 0.0% r Water Heatin `' 9 l 3 11.54 5.90 5.64 48.9% PV Credit ---- 0.00 0.00 ---- South Facing - TOTAL 135.34 133.56 1.78 1.3% Space Heating 3.32 4.05 -0.73 -22.0% Space Cooling 119.48 119.99 -0.51 -0.4% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.54 5.90 5.64 48.9% PV Credit --- 0.00 0.00 ---- West Facing - TOTAL 135.34 130.94 4.40 3.3% Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08,48,40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Non-standard roof reflectance • Window overhangs and/or fins PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below requre field verification by a certified HERS Rater. Check the individual building component sections below for any required HERS verification requirements. BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 2423 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC Systems 2423 10 DHW Sys 1 Registration Number: 214-N0062624B-000000000-0000 Registration Date/Time: 2014-08-20 08,48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CFI R-PRF-01 Page 4 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ftZ) Tilt(deg) Front Wall Zone 1 R-19 Wall 0 Front 364 98 90 Left Wall Zone 1 R-19 Wall 90 Left 586 24.012 90 Rear Wall Zone 1 R-19 Wall 180 Back 364 36 90 Right Wall Zone 1 R-19 Wall 270 Right 283 21 90 Front Wall 2 Zone 1 R-19 Wall 0 Front 182 15 90 Left Wall 2 Zone 1 R-19 Wall 90 Left 586 104.012 90 Rear Wall 2 Zone 1 R-19 Wall 180 Back 374 186.5 90 Right Wall 2 Zone 1 R-19 Wall 270 Right 808 99 90 garage wall Zone 1 R-19 Wall 0 Front 300 0 90 garage wall2 Zone 1 R-19 Wall 90 Left 200 0 90 Roof Zone 1 R-38 Roof Attic RB 482 Roof 2 Zone 1 R-38 Roof Attic RB 2036 Right garage wall Garage Garage Ext Wall 270 Right 333 0 90 Front garage wall Garage Garage Ext Wall 0 Front 333 0 90 Left garage wall Garage Garage Ext Wall 270 Right 333 0 90 Exterior Wall Garage Garage Ext Wall 0 Front 1 0 90 Roof 3 Garage Garage Roof 502 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Input File Name: 14024P3U.xml CF1 R-PRF-01 Page 5 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multipli er Area (ft2) U- factor SHG C Exterior Shading 2030-3 Window Front Wall (Front-0) --- ---- 1 18.0 0.34 0.23 4050-2 Window Front Wall (Front-0) ---- ---- 1 40.0 0.34 0.23 2680-2 frdr Window Front Wall (Front-0) ---- ---- 1 40.0 0.35 0.25 2040-3 Window Left Wall (Left-90) 6.0 6.0 0.667 24.0 0.34 0.23 2030-3 2 Window Rear Wall (Back-180) ---- ---- 1 18.0 0.34 0.23 3030-2 Window Rear Wall (Back-180) 3.0 3.0 2 18.0 0.34 0.23 3070 Window Right Wall (Right-270) ---- ---- 1 21.0 0.34 0.23 3050 Window Front Wall 2 (Front-0) ---- ---- 1 15.0 0.34 0.23 3080 frdr Window Left Wall 2 (Left-90) 6.0 6.0 0.667 24.0 0.35 0.25 4050-2 2 Window Left Wall 2 (Left-90) 5.0 5.0 1.6 40.0 0.34 0.23 4020-2 Window Left Wall 2 (Left-90) ---- ---- 1 16.0 0.34 0.23 3040-2 Window Left Wall 2 (Left-90) ---- ---- 1 24.0 0.34 0.23 3050-3 Window Rear Wall 2 (Back-180) ---- ---- 1 45.0 0.34 0.23 3016-3 Window Rear Wall 2 (Back-180) 3.0 3.0 1.5 13.5 0.34 0.23 16080 ddr Window Rear Wall 2 (Back-180) 8.0 8.0 2 128.0 0.34 0.22 3050-2 Window Right Wall 2 (Right-270) ---- ---- 1 30.0 0.34 0.23 3016-2 Window Right Wall 2 (Right-270) ---- ---- 1 9.0 0.34 0.23 4060 Window Right Wall 2 (Right-270) ---- ---- 1 24.0 0.34 0.23 2040 Window Right Wall 2 (Right-270) ---- ---- 1 8.0 0.34 0.23 20402 Window Right Wall 2 (Right-270) ---- ---- 1 8.0 0.34 0.23 2050-2 Window Right Wall 2 (Right-270) ---- ---- 1 20.0 0.34 0.23 DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door Right Wall 2 28.0 0.50 Door 16080 Front garage wall 128.0 1.00 Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08 48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CF1 R-PRF-01 Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 2040-3 12 1 10 10 0 0 0 0 0 0 0 0 0 3030-2 2 2 2 2 0 0 0 0 0 0 0 0 0 3080 frdr 12 1 10 10 0 0 0 0 0 0 0 0 0 4050-2 2 2 2 2 2 0 0 0 0 0 0 0 0 0 3016-3 2 2 2 2 0 0 0 0 0 0 0 0 0 16080 ddr 12 1 10 10 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathinglinsul. - Garage Roof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinglinsul. - Cavity: R 19 Sheathing/Insulation: - no sheathinglinsul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Attic Floor. - no attic floor - Cavity: R 38 Sheathinglnsulation - no sheathinghnsul. - R-38 Roof Attic RE; Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Inside Finish. Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinglinsul. - Cavity: - no insulation (vertical) - - no insulation Sheathing/Insulation: - no sheathinglrnsul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08:48*40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CFI R-PRF-01 Page 7of10 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab Zone 1 1941 223 None 0.8 No Slab 2 Garage 502 90 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Systeml Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2423 Registration Number: 214-NO0626248-000000000-0000 Registration Date/Time: 2014-08-20 08:48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CF1 R-PRF-01 Page 8of10 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 11.7 14 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge HVAC System1 SCSysRpt 1 Required 350 --- 14.0 Verified HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Sealed and tested 6 Attic Attic None Air Distribution System 1-hers-dist attic HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required Registration Number: 214-NO062624B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Description: Title 24 Analysis Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Input File Name: 14024P3U.xml CFI R-PRF-01 Page 9 of 10 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 54 Exhaust 0 Required Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:S3:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 3 Calculation Date/Time: 23:40, Tue, Aug 19, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P3U.xml CF1 R-PRF-01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: %�"✓�ai�ca Rudy Sains Company: Signature Date: Heritage Energy Group 2014-08-20 01:00:40 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: ResponsibleDesigner Signature: ����� Jen Wipper Company: Date Signed: California West Communities 2014-08-20 08:48:40 Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760 918 2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-No062624B-000000000-0000 Registration Date/Time: 2014-08-20 08:48:40 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report version - CF1R-07232014-595c Report Generated at: 2014-08-19T23:53:59 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CF1 R-PRF-01 Page 1 of 11 GENERAL INFORMATION 01 Project Name Plan 4 02 Calculation Description Title 24 Analysis 03 Project Location 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 07 Compliance Manager Version BEMCmpMgr 2013-2 (595c) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 2418 15 Number of Zones 1 16 Slab Area (FT2) 2031 17 Number of Stories 2 18 Addition Cond. Floor Area NA 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) NA 21 j Glazing Percentage (%) 23.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 214-N0062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Plan 4 Calculation Description: Title 24 Analysis Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Input File Name: 14024P4U.xml Page 2of11 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 2.28 3.27 -0.99 -43.4% Space Cooling 110.70 108.83 1.87 1.7% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.55 5.91 5.64 48.8% PV Credit ---- 0.00 0.00 ---- North Facing - TOTAL 125.53 119.01 6.52 5.2% Space Heating 2.28 3.74 -1.46 -64.0% Space Cooling 110.70 103.46 7.24 6.5% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.55 5.91 5.64 48.8% PV Credit ---- 0.00 0.00 ---- East Facing - TOTAL 125.53 114.11 11.42 9.1% Space Heating 2.28 3.44 -1.16 -50.9% Space Cooling 110.70 107.27 3.43 3.1 % IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.55 5.91 5.64 48.8% PV Credit ---- 0.00 0.00 ---- South Facing -TOTAL 125.53 117.62 7.91 6.3% Space Heating 2.28 2.78 -0.50 -21.9% Space Cooling 110.70 103.06 7.64 6.9% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 11.55 5.91 5.64 48.8% PV Credit ---- 0.00 0.00 ---- West Facing - TOTAL 125.53 112.75 12.78 10.2% Registration Number: 214-NO062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Page 3 of 11 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Non-standard roof reflectance • Window overhangs and/or fins PROJECT HERS FEATURES The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed in the building components tables below requre field verification by a certified HERS Rater. Check the individual building component sections below for any required HERS verification requirements. BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (sft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 4 2418 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 living Conditioned HVAC System1 2418 10.1 DHW Sys 1 Registration Number: 214-N0062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD C F 1 R-PRF-01 Project Name: Plan 4 Calculation Description: Title 24 Analysis Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Input File Name: 14024P4U.xml Page 4of11 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt(deg) Front Wall living R-19 Wall 0 Front 152 35 90 Left Wall 2x4 living R-13 Wall 90 Left 343 0 90 Rear Wall living R-19 Wall 180 Back 152 6 90 Right Wall living R-19 Wall 270 Right 343 49 90 Front Wall 2 living R-19 Wall 0 Front 172 36 90 Left Wall living R-19 Wall 90 Left 505 135.012 90 Rear Wall 2 living R-19 Wall 180 Back 394 180 90 Right Wall 2 living R-19 Wall 270 Right 828 122 90 garage wall living R-19 Wall 0 Front 210 0 90 garage wa112 living R-19 Wall 90 Left 310 0 90 Roof living R-38 Roof Attic RB 387 Roof 2 living R-38 Roof Attic RB 1652 Interior Surface living»Garage R-19 Wall1 10 garage wall right Garage Garage Ext Wall 270 Right 172 0 90 garage wall Front Garage Garage Ext Wall 0 Front 233 0 90 garage wall Left Garage Garage Ext Wall 90 Left 346 0 90 Exterior Wall Garage Garage Ext Wall 180 Back 1 0 90 Roof 3 Garage R-0 Roof Attic 542 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Attic Roof Cons 5 0.1 0.85 Yes No Registration Number: 214-No0626256-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CFI R-PRF-01 Page 5 of 11 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width(ft) Height (ft) Multipli er Area (ft) U- factor SHG C Exterior Shading 2670-2 frdr Window Front Wall (Front-0) ---- ---- 1 35.0 0.35 0.25 2030 Window Rear Wall (Back-180) ---- --- 1 6.0 0.34 0.23 3070 Window Right Wall (Right-270) ---- ---- 1 21.0 0.34 0.23 2050-2 Window Right Wall (Right-270) ---- ---- 1 20.0 0.34 0.23 2040 Window Right Wall (Right-270) ---- ---- 1 8.0 0.34 0.23 2060 Window Front Wall 2 (Front-0) ---- ---- 1 12.0 0.34 0.23 20602 Window Front Wall 2 (Front-0) ---- ---- 1 12.0 0.34 0.23 20603 Window Front Wall 2 (Front-0) ---- ---- 1 12.0 0.34 0.23 12080 ddr Window Left Wall (Left-90) 6.0 6.0 2.667 96.0 0.34 0.22 2050 Window Left Wall (Left-90) 5.0 5.0 0.4 10.0 0.34 0.23 5050 Window Left Wall (Left-90) ---- ---- 1 25.0 0.34 0.23 2020 Window Left Wall (Left-90) ---- ---- 1 4.0 0.34 0.23 3060-2 Window Rear Wall 2 (Back-180) ---- ---- 1 36.0 0.34 0.23 6060 Window Rear Wall 2 (Back-180) 3.0 3.0 4 36.0 0.34 0.23 3030-2 Window Rear Wall 2 (Back-180) ---- ---- 1 18.0 0.34 0.23 3060 Window Rear Wall 2 (Back-180) 3.0 3.0 2 18.0 0.34 0.23 9080 dr Window Rear Wall 2 (Back-180) 8.0 8.0 1.125 72.0 0.34 0.22 3060-2 2 Window Right Wall 2 (Right-270) ---- ---- 1 36.0 0.34 0.23 3030-2 2 Window Right Wall 2 (Right-270) ---- ---- 1 18.0 0.34 0.23 3050-2 Window Right Wall 2 (Right-270) ---- ---- 1 30.0 0.34 0.23 1380-2 Window Right Wall 2 (Right-270) ---- ---- 1 20.0 0.34 0.23 20402 Window Right Wall 2 (Right-270) ---- 1 8.0 0.34 0.23 20502 Window Right Wall 2 (Right-270) ---- 1 10.0 0.34 0.23 DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door Right Wall 2 28.0 0.50 Door 16080 garage wall Front 128.0 1.00 Registration Number: 214-NO062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Plan 4 Calculation Description: Title 24 Analysis Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Input File Name: 14024P4U.xml Page 6 of 11 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 12080 ddr 12 1 10 10 0 0 0 0 0 0 0 0 0 2050 0 0 0 0 0 0 0 0 0 0 0 0 0 6060 2 2 2 2 0 0 0 0 0 0 0 0 0 3060 2 2 2 2 0 0 0 0 0 0 0 0 0 9080 dr 12 1 10 10 0 0 0 0 0 0 0 0 0 Registration Number: 214-N0062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation DatefTime: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CF1 R-PRF-01 Page 7 of 11 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 Construction Name Surface Type Construction Type Framing Total Cavity R-value Assembly Layers Roofing: 10 PSF (RoofTile) Above Deck Insulation - no insulation - 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Cavity: - no insulation - Attic Roof Cons Attic Roofs Wood Framed Ceiling O.C. Inside Finish: - select inside finish - Attic Floor: - no attic floor - Cavity: - no insulation - Sheathinglnsulation - no sheathinghnsul. - R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathinghnsul. - Cavity: R 19 Sheathing/Insulation: - no sheathing/nsul. - R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Exterior Finish: Wood Siding/sheathing/decking Inside Finish: Gypsum Board Sheathing/Insulation: - no sheathingfinsul. - Cavity: R 13 Sheathing/insulation: - no sheathing/rnsul. - R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 Exterior Finish: Wood Siding/sheathing/decking Attic Floor: - no attic floor - Cavity: R 38 SheathingInsulation - no sheathingfinsul. - R-38 Roof Attic RB Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 Inside Finish: Gypsum Board Inside Finish: Gypsum Board Sheathing/insulation: - no sheathingfinsul. - Cavity: R 19 Sheathing/Insulation: - no sheathingfinsul. - R-19 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 Other Side Flnish: Gypsum Board inside Finish: Gypsum Board Sheathing/Insulation: - no sheathingfinsul. - Cavity: - no insulation (vertical) - - no insulation Sheathing//nsulation: - no sheathinghnsul. - Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. (vertical) - Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated Slab living 2031 223 None 0.8 No Slab 2 Garage 542 83 None 0 No Registration Number: 214-No062625B-000000000-0000 Registration Date/Time: 2014-08-20 08,49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CF1 R-PRF-01 Page 8 of 11 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation(QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 Name Distribution Type Number of Heaters Solar Fraction (%) DHW Sys 1 Standard 1 0.0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Instantaneous 0 0.95 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1-hers-dhw n/a n/a n/a n/a n/a HVAC SYSTEMS 01 02 03 04 05 06 07 Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC Systeml Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2418 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 214-N0062825B-000000000-0000 Registration Date/Time: 2014-08-20 08 49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CF1 R-PRF-01 Page 9 of 11 HVAC - COOLING SYSTEMS 01 02 03 04 05 Name System Type Efficiency EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 12.5 15 Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge HVAC Systeml SCSysRpt 1 Required 350 15.0 Verified HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 Supply Duct Name Type Duct Leakage Insulation R-value Location Return Duct Bypass Duct HERS Verification Air Distribution System 1 Ducts located in unconditioned Sealed and tested 6 Attic Attic None Air Distribution attic System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 Required HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name VerifiedFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 214-N0062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CF1 R-PRF-01 Page 10 of 11 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification IAQ Fan 54 Exhaust 0 Required Registration Number: 214-N0062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2014-08-20T00:39:17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 4 Calculation Date/Time: 00:24, Wed, Aug 20, 2014 Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml CFI R-PRF-01 Page 11 of 11 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rudy Sains Company: Signature Date: Heritage Energy Group 2014-08-20 01:07:06 Address: CEA/HERS Certification Identification (If applicable): 470 Wald City/State/Zip: Phone: Irvine, CA 92618 949 584 1052 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Jen Wipper Company: Date Signed: California West Communities 2014-08-20 08:49:05 Address: License: 5927 Priestly Drive, Suite 103 N/A City/State/Zip: Phone: Carlsbad, CA 92008 760 918 2824 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 214-N0062625B-000000000-0000 Registration Date/Time: 2014-08-20 08:49:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-S95c Report Generated at: 2014-08-20T00:39:17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Haciendas -Plan 1 Date 8/20/2014 System Name HVAC System Floor Area 1,941 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,258 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 75,000 25,393 2,327 524 25,721 Total Output (Btuh) 75,000 0 Output Btuh/s ft 38.6 1,733 1,484 Cooling System 0 0 Output per System 46,300 0 0 0 0 Total Output (Btuh) 46,300 0 2,327 0 Total Output (Tons) 3.9 1,733 1,484 Total Output (Btuh/s ft) 23.9 Total Output s ft/Ton 503.1 1 28,859 28,689 Air System CFM per System 1,565 HVAC EQUIPMENT SELECTION Airflow cfm 1,565 14/80% 37,663 1,697 75,000 Airflow (cfm/s ft) 0.81 Airflow (cfm/Ton) 405.6 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 37,663 1,697 75,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 67 OF 67 OF 115 OF 0 Outside Air 0 cfm Supply Fan Heating Coil AL 1,565 cfm 67 OF 114 OF ROOM f� 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 76/62OF 55/54OF Outside Air Ar 0 cfm Supply I Fan Cooling Coil 1,565 cfm 76/62OF 56 / 54 OF 47.8 pro ROOM 9 75/62OF EnergyPro 6.2 by EnergySoft User Number: 7244 ID. 14024 Page 1 of 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Haciendas -Plan 4 Date 8/20/2014 System Name HVAC System Floor Area 2,418 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,623 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 75,000 32,662 3,538 675 33,113 Total Output (Btuh) 75,000 0 Output Btuh/s ft 31.0 1,808 1,470 Cooling System o 0 Output per System 46,300 0 0 0 0 Total Output Btuh 46,300 0 3,538 0 Total Output (Tons) 3.9 1,808 1,470 Total Output (Btuh/s ft) 19.1 Total Output s ft/Ton 626.7 36,277 36,052 Air System CFM per System 1,565 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,565 15/80 37,240 2,301 75,000 Airflow (cfm/s ft) 0.65 Airflow (cfm/Ton) 405.6 Outside Air (%) 0 0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 37,240 2,301 75,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 67 OF Outside Air 0 cfm Supply Fan 1,565 cfm 67 IF 67 OF 115 °F Heating Coil 114 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 76 / 62 OF 76 / 63 IF 55 / 54 IF Outside Air Ar 0 cfm Supply Fan Cooling Coil 56 / 54 IF 1,565 cfm 48.7 pro ROOM 76 / 62 OF 75162 IF EnergyPro 6.2 by EnergySoft User Number: 7244 ID: 14024 Page 1 of 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Haciendas -Plan 2 Date 8/20/2014 System Name HVAC System Floor Area 2,042 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,354 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 75,000 27,209 2,463 554 27,146 Total Output (Btuh) 75,000 0 Output Btuh/s ft 36.7 1,857 1,566 Cooling System 0 0 Output per System 46,300 0 0 0 0 Total Output Btuh 46,300 0 2,463 0 Total Output (Tons) 3.9 1,857 1,566 Total Output (Btuh/s ft) 22.7 Total Output s ft/Ton 529.2 1 30,923 30,277 Air System CFM per System 1,565 HVAC EQUIPMENT SELECTION Airflow cfm 1,565 14/80 37,686 1,706 75,000 Airflow (cfm/s ft) 0.77 Airflow (cfm/Ton) 405.6 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 37,686 1,706 75,000 Jan 1 AM Outside Air cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 IF 67 OF Outside Air 0 cfm Supply Fan 1,565 cfm 67 IF 67 OF 115 OF Heating Coil 114 IF ROOM) 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 76/62OF 55/54OF Outside Air 0 cfm Supply Fan Cooling Coil 56 / 54 OF 1,565 cfm 47.9 % ROOM 76 / 62 IF 75 l 62 IF EnergyPro 6.2 by EnergySoft User Number: 7244 ID: 14024 Page 1 of 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Haciendas - Plan 3 System Name HVAC System ENGINEERING CHI EC of Svstems Total Output (E Output Btuh/s CoolingSystem Output r S s Total Output E Total Output (I Total Output (E Total Output s Air System CFM per Syste Airflow cfm Airflow (cfm/sc Airflow (cfmfTc Outside Air (%. Outside Air cfi Note: values above CKS SYSTEM LOAD 1 0 Total Room Loads 0 Return Vented Lighting 0.0 Return Air Ducts Return Fan 1 Ventilation 1 Supply Fan 0.0 Supply Air Ducts In) 0.0 29,076,000.0 TOTAL SYSTEM LOAD 0 HVAC EQUIPMENT SELECTION 0 Furnace - A/C 0.00 0.0 0.0 % Total Adjusted System Output I 0.00 (Adjusted for Peak Design conditions) at ARI conditions TIME OF SYSTEM PEAK rCHROMETRICS (Airstream Temperatures at Time Date 8/20/2014 Floor Area 2,423 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,747 34,434 3,521 929 35,387 0 1,906 1,571 0 0 0 0 0 0 0 0 0 1,906 1,571 38,246 3,521 38,528 11 0 01 11 0 0 Aug 3 PM Jan 1 AM 26 OF 67 OF 105 OF Outside Air 0 cfm Heating Coil 104 OF ROOM 67 OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 76/63OF 55/54OF Outside Air 0 cfm 76/63OF Cooling Coil 56 / 55 OF 49.4 % ROOM IL_ 75 / 62 OF EnergyPro 6.2 by EnergySoft User Number: 7244 ID: 14024 Page 1 of dI Date 8/20/2014 Floor Area 2,423 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,747 34,434 3,521 929 35,387 0 1,906 1,571 0 0 0 0 0 0 0 0 0 1,906 1,571 38,246 3,521 38,528 11 0 01 11 0 0 Aug 3 PM Jan 1 AM 26 OF 67 OF 105 OF Outside Air 0 cfm Heating Coil 104 OF ROOM 67 OF 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 76/63OF 55/54OF Outside Air 0 cfm 76/63OF Cooling Coil 56 / 55 OF 49.4 % ROOM IL_ 75 / 62 OF EnergyPro 6.2 by EnergySoft User Number: 7244 ID: 14024 Page 1 of dI