HomeMy WebLinkAbout06-1049 (CSCS) Title 24Title 24 Report for:
W
ashingto Park (Submajor 5)
x--46ashington Street
—SLa Quinta, CA 92253e
' -Projedt'Designer: ,.
• KKE Architects, Inc
525 East Colorado Boulevard (Fourth Floor)
Pasadena, CA 91101
(626)796=8230 - CITY OF LAUIN
Q TA
• BUILDING & SAFETY DEPT.
Report Prepared By: APPROVED
FOR CO STRUCTION
SIA GARESTANI, P. E.11 '
SPEC Engineering 1 DATE_2 06 BY
6800 Owensmouth Ave. #140(96_ 69
Woodland Hills, .CA 91303
K. (818) 592-6643
Job Number:
06-002
Date:
4/28/2006
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed byEnergySoft, LLC - www.enetgysoff.com.
EnergyPro 4.1 by EnergySoft Job Number: 06-002 User Number: 3358
i
r
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -
PROJECT NAME
Washington Park Subma'or 5
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
4/28/2006
PROJECT ADDRESS
46-600 Washington Street La Quinta
DATE OF PLANS
os -o7 -os
BUILDING CONDITIONED FLOOR AREA
�
I
SIA GARESTANI P.E..
PRINCIPAL DESIGNER - ENVELOPE
KKE Architects, Inc
TELEPHONE
(626) 796-8230
Biiildmg Permd # x;
DOCUMENTATION AUTHOR
SPEC Engineering
TELEPHONE
(818) 592-6643
Checked liy/Date
EnforcementAgency Use
GENERAL INFORMATION
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compli be approach.
The documentation preparer hereby certifies that the documentation Is accurate and comp!00
DATE OF PLANS
os -o7 -os
BUILDING CONDITIONED FLOOR AREA
12, 021 sy.Ft.
SIA GARESTANI P.E..
CLIMATE ZONE
15
BUILDING TYPE
NONRESIDENTIAL HIGH RISE RESIDENTIAL
HOTEL/MOTEL GUEST ROOM
PHASE OF CONSTRUCTION
NEW CONSTRUCTION ❑ ADDITION
❑
EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compli be approach.
The documentation preparer hereby certifies that the documentation Is accurate and comp!00
DOCUMENTATION AUTHOR
SIGNATURE
SIA GARESTANI P.E..
The Principal Designer hereby certifys that the proposed building desig res din this set of construction docume is is
consistent with the other compliance forms and worksheets, with t g ifications, and with any other calculations su . itted with this
permit application. The proposed building as designed meets the/enrgy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
F] F-] 1. 1 hereby affirm that I am eligible under a provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, or I am a licensed architect.
F] F] R 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
❑ F-1 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ENV -1
Required Forms
PRINCIPAL ENVELOPE DESIGNER - NAMES
LIC. NO.
DAT
KKE Architects Inc
0%
b
ps Q�
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Lighting Compliance Not In The Scope Of
Required Forms
This-SQb
PRINCIPAL LIGHTING DESIGNER - NAME
SIGNATURE
LIC. NO.
DATE
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Required For s ECH-1 MECH-2 MECH-3 MECH-5
PRINCIPAL MECHANICAL DESIGNER -NAME SIGNATU LIC. NO DATE
SIA GARESTANI y�
P.E. MZ 2,# o
I EnergyPro 4.1 by EnergySoft User Number: 335 PzJob Number 06-002 Page:3 of 19
S
PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PERF-'
PROJECT NAME DATE
Washington Park (Submaior 5) 4/28/2006
ENERGY COMPONENT
Standard
Design
Space Heating
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
0.22
263.71
32.28
0.00
0.00
58.85
165.26
82.18
0.00
TOTALS: 602.49
Percent better than Standard:
Proposed Compliance
Design Margin
0.04
-33.89
-2.26
0.00
0.00
3.06
0.00
0.00
o.00
635.55 -33.05
.a StaOtlaN,
.�..>.-- .:•:' : _e . ProposaA .. .
Conditioned Floor Area
Unconditioned Floor Area
Conditioned Footprint Area
Fuel Type
12,021
Ce�f(!A
1
0
4
o
4
Natural Gas
"Tgam
Front Elevation
1,472
sqft.
658
sqft.
44.7%
Left Elevation (N)
F
9, 20 40 60 8.0 100120140180180 200 220240 260 280
0
kBtWsgO-yr
-5.5% ( -5.5% exclud
Building Orientation
Number of Stories
Number of Systems
Number of Zones
270 deg
Conditioned Floor Area
Unconditioned Floor Area
Conditioned Footprint Area
Fuel Type
12,021
sqft.
sqft.
sqft.
1
0
4
o
4
Natural Gas
Orientation
Gross Area
Glazinq Area
Glazing
Ratio
Front Elevation
1,472
sqft.
658
sqft.
44.7%
Left Elevation (N)
1,176
sqft.
0
sqft.
0.0%
Rear Elevation E
1,472
sqft.
0
sqft.
0.0%
Right Elevation (s)
Total
Roof
1,176
5,296
12,021
sgft.
sqft.
sqft.
0
658
E=�
sqft.
sqft.
sqft.
0.0%
Standard Proposed
Lighting Power Density 1.500 W/sqft. 1.500 W/sgft.
Prescriptive Env. Heat Loss 1,370 Btu/h 1,552 Btu/h
Prescriptive Env. Heat Gain 133,94 Btu/h-F 166,462 Btu/h-F
Remarks:
I EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number 06-002 Page:4 of 19
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
PROJECT NAME
DATE
Washington Park (Submajor 5)
4/28/2006
ZONE INFORMATION
Floor Inst
Ctrl
* Allowed
LPD'
{Proc i.
Area LPD
YCrealts
7Area;
Tailored
;Loads:
System Name Zone Name Occupancy Type (sgfL) (W/sq
Y /s�p2�
z 3
a
RTU -1 Zone 1 Comp Bldg Retail and Wholesale 3,045 '1.50
;
RTU -2 Zone 2 Comp Bldg Retail and Wholesale 3,100 '1.50
RTU -3 Zone 3 Comp Bldg Retail and Wholesale 2,831 '1.50,
i s Y,
s u:;•
RTU -4 Zone 4 Comp Bldg Retail and Wholesale 3,045 '1.50
# W
c.
.•q�
)
Y � :'."
1. ., �im4
t
�. $.5'{.x�+�"
Z N{ 9.- 'f�
,:j2.
i'a yap •'�
� ��
f .^� tp✓,.i,
091M`..,.M
,.
•
�,�§fir
M`�hs::�'
' ��t�
t ��`'i' �. �'
is
a,� f•^.
n.�' ^>r*`�
i .�•1.^,.
"fin 44 5;
A1p
t
vpa
Notes: 1. See LTG -2-C 2. See LTG -4-C3. See LTG -5-C 4. See LTG -6-C
Items above
regwrespecial documentation'
(items marked with asterisk, see LTG -2 -C by others) (by others)
�xr Maw
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
... • — — -U--.,.Y ....,..... r,oY ar.v...a. —LUMwn w uro morns spuLanou in ims cneCKIIST. i nese Items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
The HVAC System "CARRIER 50HJQ012" includes Demand Control Ventilation per Standards Section 121.
The Zone "Zone 3" has a West Display Perimeter Credit of 66 ft.
• L
- - --r••-••-• --.+ — .4910 peon ovnnanee apprvacn appucation nave specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant
Authorized Sianature or Stavin
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:5 of 19
1
CERTIFICATE OF COMPLIANCE ENV -1-C
PROJECT NAME`. DATE
WaS'hin ton Park Subma'or 5 4/28/2006
OPAQUE SURFACES s
#
Surface
Type
Area U -Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond:
Status
Joint Appendix
IV Reference Location / Comments
1
Wall
550.
0.065
R-19
R-0.0
0
90
New
09-A7
Zone 1
2
Roof
3,045
0.034
R-30
R-0.0
` 0
0
New-
02-A26
Zone 1
3
Wall
374
0.065
R-19
R-0.0
0
90
New.
09-A7
Zone 2
4
Wall
248
0.065
R-19
R-0.01
180.
-90
New
09-A7
Zone 2
5
Wall -
1,472
0.065
R-19
R-0.0
90
90 -
New
09-A7
Zone 2
6
Roof
3,100
0.034
R-30
R-0.0
0 +
• 0
New
02-A26
Zone 2
7
Wall
252
0.065
R-19
R-0.0.
0
90
New'
09-A7
Zone 3
8
Wall
252
0.065
R-19
• R-0.0
180
90
New
09-A77
Zone 3
9
Wall
8141
0.065
R-19
R-0.0
270
'90
New
09-A7
Zone 3
10
Roof
2,831
0.034.
R-30
R-0.0
0
0
New
02-A26
Zone 3
11 Wall
676
0.065
R-19
R-0.0
180 •
. 90
New
09-A7,
Zone 4
12
Roof
3,045
0.034
R-30
R-0.0
0 =
0
New -
02-A26
Zone 4
,
1
FENESTRATION SURFACES
More than or equal to 10,000 sq.fL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from
F S1AnAaMC T.M. 11R_A -A o rnA: ,. .:�..,n �... f:�...a :...�.. ___.��-'- -_'`-' -"-- --- -- _ .. .. .... _ -
#
IType
Act. Cond.
Area U -Fac 1- SHGC2 Am. Stat. Glazin4 Type
Location/
Comments
1
Window
Front
110 1.2801116-A
0.72 INFRC
270
New
Double Clear Default NM
Zone 3
2
3
4
Window
Window
Window
Front (W)
. Front
Front
110 1.2801116-A
75 1.2801116-A
40 1.2801116-A
0.72 NFRC
0.72 NFRC
0.72 NFRC
270
270
270
New
New .
-New
Double Clear Default(NM)
Double Clear Default(NM)
Double Clear Default NM
Zone 3
Zone 3
Zone 3 t
5
6
7
8
Window Front
Window .Front
Window Front (W)
Window Front •
28 1.250 NFRC 0.82 NFRCI;
75 1.2801116-A 0.72 NFRCI
110 1.280 116-A • 0.72 NFRCj
110 1.280 116 -Al 0.72 NFRC
270 New
270 New
270 ' New
270 New
I Single Clear Default NM
I Double Clear Default(NM)
Double Clear Default(NM)
Double Clear Default NM
Zone 3
, Zone 3
Zone 3
Zone 3
► 6.0 0.1 '
6.0
6.0.
5
None
0.76
6.2 4.5
4.0 0.1
4.0-
4.0 -
6
None
0.76
• 11.0 6.7
6.0 0.1
-6.0 -
6.0
7
None
0.76
11.0 10.0
, 4.0 0.1
4.0
4.0
8
None
0.76
11.0-10.0
4.0 0.1
4.0"
4.0
111 UaHnr Ir -11 A -e nnfa % Tawsf......
c......a
"
-. - _ -'--...-_._ .._... ,....... V. a'i....,,....
Type: 11&B Default Table from Standards, COG Center of Glass, NFRC labeled Value - -
EXTERIOR SHADING
`
#
1
Exterior Shade Type
None
SHGC
0.76
Window
Hgt. Wd.
11.0 10.0
Overhang Left Fin Right Fin
` Len: H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t.
4.0 0.1 4:0 4.0
2
None
0.76
11.0. 10.0
4.0 ` 0.1
4.0
4.0
3
None
0.76
".11.0 6.7
6.0 0.1
6.0
6.0
4
None
0.76
3.2 12.5
► 6.0 0.1 '
6.0
6.0.
5
None
0.76
6.2 4.5
4.0 0.1
4.0-
4.0 -
6
None
0.76
• 11.0 6.7
6.0 0.1
-6.0 -
6.0
7
None
0.76
11.0 10.0
, 4.0 0.1
4.0
4.0
8
None
0.76
11.0-10.0
4.0 0.1
4.0"
4.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
_
❑The
proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a telling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sa.R if this
box is checked ENV.A r mum An fillnA n.A .•A•-..-..w...w.-_ .._.__.._ ^----�-"-- ^--- -"- _
Run Initiation Time: 03/07/06 1
EnergyPro 4.1 by EnergySoft ' User Number: 3358
Run Code: 11417696T6
Job Number: 06-002 - Page:6 of 19
+ f r
CERTIFICATE OF COMPLIANCE MECH-1-C
NAME
DATE
Washington Park (Submajor 5) 4/28/2006
Designer: .
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor; design professional or an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
certificates and operating and maintenance information meet the re uirements of Section 10-1 03 b and Title 24 Part 6
STATEMENT OF COMPLIANCE
❑ MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems. Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-4-A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction inspection.
❑ MECH-5-A: Air Distribution Acceptance Document
Equipment requiring acceptance testing
This test required If the unit serves 5,000 ft2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an
attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
❑ MECH-6-A: Demand Control Ventilation Acceptance Document
Equipment requiring acceptance testing
All new DCV controls installed on new or existing packaged systems must be tested.
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VAV fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A:-Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hot water systems.
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btufhr.
-Water-loop Heat Pump Controls
Applies to all, new watertoop heat pump systems where the combined loop pumps are greater than 5 hp.
-Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:7 of 19
[AIR SYSTEM REQUIREMENTS' Part 1 of 2` MECH-2-C
PROJECT NAME DATE
Washington Park Subma•or 5 4/28/2006
c SYSTEM FEATURES
k ITEM OR SYSTEM TAG(S)
Number of Systems E "
AIR SYSTEMS, Central or Single Zone
RTU -1'
RTU -2
RTU -3
112(a)
10.3 EER
10.3 EER
T-24
MANDATORY MEASURES. Section A 'Reference on Plans or Specification
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
.,
Calculated Heating Capacity x 1.43 2 '
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2' 1
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
112(a)
3.30 COP
3.30 COP
3.30 COP
112(a)
10.3 EER
10.3 EER
10.3 EER
112(b)
Yes
Yes
Yes
112(c), 115(a)
n/a : _
n/a
n/a
121(b)
No
No
No
121(b)
1020 cfm .
1038 cfm
948 cfm
121 c
No
No ••
No
121(c) '
Yes
- Yes
Yes
121(c). 122(e)
Programmable Switch
Programmable Switch
Pro rammable Switch
122(e)
Heating & Cooling Required
Heating & Cooling Required
Heating & Cooling Required
122
•
Auto
Auto
i
Auto
122(8)
n/a
' n/a
n/a
123
-
124
R-8.0
, - R-8.0
R-8.0
144 a & b
n/a
'n/a'
n/a
144 a & b
71,201 btuh '
71,201 btuh
71,201 btuh
144 a & b
n/a
n/a
n/a
144 a & b
103,439 btuh
- 103,861 btuh
102536 btuh
144 (c)Constant
Volume
Constant Volume
Constant Volume
144 (c) '
144 (c)':
_Yes
Yes
Yes
144 d .
No
No
No
144 a
_Fixed Tem Non-Inte
Fixed Tem Non-Inte
Fixed Tem Non-Inte
144 M.
Constant Tem
=' -Co-nstantTemp
Constant Tem
144 (f)
r ° Constant Temp
Constant Temp
Constant Temp
1144'(k)
No , . '
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in^reference,ot plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERFA for performance method duct sealing requirements. '
f
SIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
(PROJECT NAME DATE
Washington Park (Submajor 5) 4/28/2006
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
T-24
MANDATORY MEASURES Section
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
AIR SYSTEMS, Central or Single Zone
RTU -4
1
Reference on Plans or Specification 1
112(a)
3.30 COP
112(a)
10.3 EER
112(b)
Yes
112(c), 115(a)
n/a
121(b)
No
121(b)
1020 cfm
121(c)
No
121(c)
Yes
121(c), 122(e)
Programmable Switch
122(e)
Heating & Cooling Required
122
Auto
122(g)
n/a
123
124
R-8.0
144 a & b
n/a
144 a & b
71,201 btuh
144 a & b
n/a
144 a & b
103,453 btuh
144 c
Constant Volume
144 (c)
144 c
Yes
144 d
No
144 a
Fixed Tem Non-Inte
144
Constant Tem
144(f)
Constant Temp
144 (k)
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
N0TFR TO FIFI n - Fnr Rnilriinrn rlanftr►nan• i I-- r%—h.
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:9 of 19
OATER SIDE SYSTEM REQUIREMENTS Part 2 -of 2 MECH-24
PROJECT NAME, �.,., .. w =sr DATE
Washington Park Subma'or 5 4/28/2006
SYSTEM FEATURES
' 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops
ITEM OR SYSTEM ,TAG(S)
Number of Systems
T-24 -
MANDATORY MEASURES,. Section Reference on Plans or Specification)
Equipment Efficiency 112(a)
Pipe Insulation
PRESCRIPTIVE MEASURES '
Calculated Capacity
144 (a & b)
Proposed Capacity
144 (a& b) '
Tower Fan Controls
144 h
Tower Flow Controls
144 h
Variable Flow System Design
144 •
Chiller and Boiler Isolation
144 •
CHW and HHW'Reset Controls - '
144
WLHP Isolation Valves
144 '
VSD on CHW, CW & WLHP Pumps > 5
144
HP ,
DP Sensor. Location
144 •
1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph
number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. a
2: Water side systems include wet side system using other liquids such as glycol or brine. - {
Service Hot Water, Pool Heating
ITEM OR SYSTEM TAG(S) DHW Heater
Number of Systems 3
MANDATORY MEASURES Reference on Plans or Specification) -
Water Heater Certification
.113 (a)
Water Heater Efficiency
113 b J. -
Service Water Heating Installation .
113 (c)
Pool and Spa Efficiency and Control
114 (a)'
Pool and Spa Installation
114 b
Pool Heater - No Pilot Light
115 (c)
Spa Heater - No Pilot Light
115 d
CHRONOMITE S-30 LP
'98%
h/a '
n/a
-n/a
n/a
1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and
paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column.
I Run Initiation Time: 03/07/06 14.04.36 Run Code: 1141769076 '
EnergyPro 4.1 by EnergySoft User Number. 3358 Job Number' 06-002 Page: 10 of 19
ti
MECHANICAL VENTILATION MECH-3-C
PROJECT NAME DATE
Washington Park (Submajor 5) 1 4/28/2006
PRESCRIPTIVE REHEAT
LIMITATION Section 144(d))
MECHANICAL VENTILATION Section 121(b)2)
AREA BASIS
OCCUPANCY BASIS
VAV MINIMUM
A
B
C
D
E
F
G
H
I
J
K
L
M
N
ZONE/SYSTEM
n
Wim»
p
a
n
T�3
°0
..
ao� 3
n��
... y
3
Z
3
°�
m
0
m� n
0�3
p
�e
r 00
�cn
--a
3'
,»
v3A
�oC
G) .�, C
n
c�;
3�<c
D 7
p-*
n®o
3c�
�
n
��
a�
A
0 o_
w3 3
4000
n -
-n`
H
(D
»�
C391
7 7
,. D
w
D
Zone 1
3,045
0.221
670
68.01
15.0
1,0201
1,020
1,0201
1
RTU -1
Total
1,020
1,020
Zone 2
3,100
0.22
682
69.2
15.0
1,038
1,038
1,038
RTU -2
Total
1,038
1,038
Zone 3
2,83
0.22
623
63.2
15.0
948
948
948
RTU -3
Total
948
948
Zone 4
3,045
0.22
670
68.0
15.0
1,020
1,020
1,020
RTU -4
Total
1,020
1,020
Minimum ventilation to pgr SectionTable 121 -A
E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load fore ress purposes fors aces without fixed seating.
H Re uired Ventilation Air REO'D V.A. is the lamer of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G).
1 Must be greater than ore ual to H or use Transfer Air column N to make up the difference.
J Design fan supply dm Fan CFM x 30%; or
K Condition area ft. sq.) x 04 cfmtlt. sq. 0 or
L Maximum of Columns H, J, K, or 300 dm
M This must be less than or equal to Column L and greater that orequal to the sum of Columns H + N.
N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or
equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M.
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page:.11 of 19
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
Washington Park Subma'or 5
DATE 4/28/2006
CHILLER AND TOWER SUMMARY
System Type
Distribution Type
Qty
Rated
Input
Vol.
(Gals.)
Condition
Status
Ext
R -Val.
CHRONOMITE S-30 LP
Efficiency
Tons
3
PUMPS
0
Equipment Name
Equipment Type
Qty.
Tot.
Qty
GPM
BHP
Motor
Eff.
Drive
Eff.
Pump
Control
QHW / BOILER SUMMARY
Hot Water P mp Hot Water Piping Len th ft
Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
CENTRAL SYSTEM RATINGS
HEATING COOLING
Aux. Condition
System Name System Type Qtv Out ut kW Eff. Output Efficiency Status Economizer Type
CARRIER 50HJQ012 Packaged DX 4 114,000 0.0 3.30 COP 119,40010.3 EER New Fixed Temp (Non-lnte )
CENTRAL SYSTEM FAN SUMMARY
System Name Fan Type
CARRIER 50HJQ012
Constant Volume
Motor Location
Energy
Factor
or RE
Standby
Loss or
Pilot
TANK INSUL.
System Name
System Type
Distribution Type
Qty
Rated
Input
Vol.
(Gals.)
Condition
Status
Ext
R -Val.
CHRONOMITE S-30 LP
Instant Elec
No Pipe Insulation
3
9,429
0
New
0.98
n/a
n/a
Hot Water P mp Hot Water Piping Len th ft
Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
CENTRAL SYSTEM RATINGS
HEATING COOLING
Aux. Condition
System Name System Type Qtv Out ut kW Eff. Output Efficiency Status Economizer Type
CARRIER 50HJQ012 Packaged DX 4 114,000 0.0 3.30 COP 119,40010.3 EER New Fixed Temp (Non-lnte )
CENTRAL SYSTEM FAN SUMMARY
System Name Fan Type
CARRIER 50HJQ012
Constant Volume
Motor Location
PP
CFM
BHP
Motor
Eff.
Drive
Eff.
CFM
BHP
Motor
Eff.
Drive
Eff.
Draw -Through
4,000
0.80
77.0%
97.0%
none
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Page: 12 of 19
ENVELOPE MANDATORY "MEASURES 'ENV -MM
PROJECT NAME
Wash
DATE
n Park (Submajor 5)
DESCRIPTION
Designer
Enforcement
❑X § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply
with the California Quality Standards for Insulating material, Title 20, Chapter 4, Article
"
3
] § 118(c) All Insulating Materials shall be Installed; in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
§117(a) All Exterior Joints and openings in the bulid Ing that are observable, sources of air .
leakage shall be caulked, gas keted,.weatherstripped or otherwise sealed.
IFX §116(b) Site Constructed Doors, Windows and Skylights shall be. caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors and
fire doors).
X❑ § 118(a)1 Manufactured Doors and Windows Installed shall have air. Infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U -value according to NFRC procedures.
X❑ § 118(e) Demising Walls in Nonresidential Buildings:. '
The opaque portions of framed demising walls.in nonresidential buildings shall have
Insulation with an installed R -value of no less than R-11 between framing members.'
. ,. - .. 4
-. j
EnergyPro By EnergySoft User Number: User Job Number: 06-002 Page: 13 of 19
MECHANICAL MANDATORY MEASURES Part 1 of 2MECH-MM
PROJECT NAME DATE
Washington Park (Submajor•5) 4/28/2006
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
0 §111 Any appliance for which there is a California standard established in the
Appliance Efficiency Regulations will comply with the applicable standard.
§1`1 5(a) Fan type central furnaces shall not have a pilot light.
0 § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
Standards Section 123.
§ 124 Air handling duct systems shall be installed and insulated in compliance with
Sections 601, 603 and 604 of the Uniform Mechanical Code.
Controls.
§ 122(e) Each space conditioning system shall be installed with one of the following:
D § 122(e)1A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the
requirements of Section 112 (d)) shall be installed with an automatic time switch
with an accessible manual override that allows operation of the system during
off -hours for up to 4 hours. The time switch shall be capable of programming
different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at
least 10 hours if power is interrupted; or
a§ 122(e)1I§ An occupancy sensor to control the operating. period of the system; or
§ 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of
the system. `
0 § 122(e)2 Each space conditioning system shall be installed with controls that temporarily -
restart and temporarily operate the system as required to maintain a'setback
heating and/or a setup cooling thermostat setpoint.
§ 122(8) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with
isolation zones. Each zone: shall not exceed 25,000 square feet; shall be .
provided with isolation devices, such as valves or dampers, that allow the supply
of heating or cooling to be setback or shut off independently of other isolation
areas; and shall be controlled by a time control device as described above.
§ 122(a1£b) Each space conditioning system shall be controlled by an individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower: For cooling, the
control shall be adjustable up to 85 degrees F or higher. Where used for both
heating and cooling, the control shall be capable of providing a deadband of at
least 5 degrees F within which the supply of heating and cooling is shut off or
reduced to a minimum.
X § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and
adjustable setpoint stops accessible only to authorized personnel.'
§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance
supplementary heater operation when the heating load.can be met by the heat
pump alone.
EnergyPro By EnergySoft User Number: User Job Number: 06-002 Page: 14 of 19
t
IMECHANICAL MANDATORY MEASURES Part 2 of Z MECH-MM
PROJECT NAME 1 ; DATE
Washin ton Park Subma'or 5 4/28/2006
Description
Designer
Enforcement
Ventilation
FX 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at
the ventilation rates as specified on these plans.
X] § 122(o Gravity or automatic dampers interlocked and closed on; fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and `
exhaust systems.
X❑ § 122(o All gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers In all openings to the outside, except for combustion air'
-openings.
§ 121(f)1 Air Balancing: The system shall be balanced In accordance with the National.
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
n § 121(02 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
Installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the Installing licenced C-20.mechanical contractor, or (3) the,
person with overall responsibility for the design of the ventilation system; or,
❑ § 121(03 Outside Air Measur®ment: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
basis and displaying that quantity on a readily accessible display dlvlce; or • .•.
§ 121(04 Another method approved by the Commission. .
Service Water Heating Systems .
1�1§ 113(b)2 1f a circulating hot water system Is Installed,' shall have a control capable of
automatically turning off the circulating pump(s) when hot water Isnot required.-
X] § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the
outlet temperature to 110 degrees F.
1^1§ 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the
following: '
Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per
'
minute.
Foot actuated control valves, and outlet devices that limit the flow of hot water to a
maximum of 0.75 gallons per minute:
Proximity sensor actuated control valves, and outlet devices that limit the flow of hot.
water to a maximum of 0.75 gallons per minute.
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
'
of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor .
controls). `
EnergyPro By EnergySoft User Number: User Job Number: 06-002 ' Page: 15 of 19
MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park Subma'or 5 4/28/2006
SYSTEM NAME FLOOR AREA
RTU -1 3 045
Number of Systems
1
Heating System
Output per System
114,000
Total Output (Btuh)
114,000
Output (Btuhlsgft)
37.4
Cooling System
Output per System
119,400
Total Output (Btuh)
119,400
Total Output (Tons)
9.9
Total Output (Btuh/sgft)
39.2
Total Output (sgft/Ton)
306.0
Air System
CFM per System
4,000
Airflow (cfm)
4,000
Airflow (cfm/sgft)
1.31
Airflow (cfm/Ton)
402.0
Outside Air (%)
25.5
Outside Air (cfmisgft)
0.33
Note: values above gl
JEATING SYSTEM
26.0 of
Outside Air
1020 cfm
69.9 of
'DOLING S
12.0 / 77.9 of
Outside
��
1020 cfm
74.5/62.0 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
IICOILHTG.PEAK
CFM
I Sensiblel
Latent
I I CFM
I Sensible
1,992
40,284
12,914
165
6,128
0
2,014
306
0
0
1,020
40,712
18,517
1,020
47,662
0
0
2,0141
1 306
85,0601 31 43 54 403
CARRIER 50HJQ012 103,439 5,414 71,201
Total Adjusted System Output 103,439 5,414 71,201
(Adjusted for Peak Design Conditions)
at ARI conditions L-
YCHROMETRICS (Airstream Tei
58.7 of 105.0 of
Heating Coil
TIME OF SYSTEM PEAK Jul 3 pm Jan 12am
at
Supply Fan
4000 cfm
105.0 of
-� Supply Air Ducts
104.9 of
ROOMS
70.0 of
h Return Air Ducts 4
drstream Temperatures at
84.0 / 66.6 of. 55.0 / 53.7 of
Cooling Coil
Supply Fan
4000 cfm
55.0 / 53.7 of
-� Supply Air Ducts
55.5 / 53.9 of
50.7% R.H. ROOMS
74.0 61.9 of
h Return Air Ducts 4
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number: 06-002 Paoe:16 of 19
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park Subma'or 5 4/28/2006
SYSTEM NAME FLOOR AREA
RTU -2 3,100
Number of Systems
1
Heating System
Output per System
114,000
Total Output (Btuh)
114,000
Output (Btuh/sgft)
36.8
Cooling System
Output per System
119,400
Total Output (Btuh)
119,400
Total Output (Tons)
9.9
Total Output (Btuh/sgft)
38.5
Total Output (sgft/Ton)
311.6
Air System
CFM per System
4,000
Airflow (cfm)
4,000
Airflow (cfm/sgft)
1.29
Airflow (cfmffon)
402.0
Outside Air (%)
25.9
Outside Air (cfm/sgft)
0.33
Note: values above given at ARI conditions
26.0 of
Outside Air
1038 cfm
69.9 of
5A F OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
I Sensiblel
Latent
I I CFM
I Sensible
2,23
45,117
13,147
285
10,626
0
2,256
531
0
0
1,038
41,386
18,812
1,038
48,465
0
0
2,2561
531
91,045T 31,959 60154
CARRIER 50HJQ012 103,861 5,167 71,201
Total Adjusted System Output 103,861 5,167 71,201
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am
105.0 of
Heating Coil
Supply Fan
4000 cfm
105.0 OF
-� Supply Air Ducts
104.9 of
ROOMS
70.0 OF
h Return Air Ducts 4
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112.0 / 77.9 OF 84.3 / 66.7 of 55.0 / 53.7 of 55.0 / 53.7 of
Supply Air Ducts
Outside Air
1038 cfm
Cooling Coil Supply Fan 55.5 / 53.9 of
4000 cfm 50.7% R.H. ROOMS
74.5/62.1°F 74.0/61.9OF
Return Air Ducts
I EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number 06-002 Page: 17 of 19
I
l
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Washington Park Subma'or 5 4/28/2006
SYSTEM NAME FLOOR AREA
RTU -3 2,831
Number of Systems
1
Heating System
Output per System
114,000
Total Output (Btuh)
114,000
Output (Btuh/sgft)
40.3
Cooling System
Output per System
119,400
Total Output (Btuh)
119,400
Total Output (Tons)
9.9
Total Output (Btuh/sqft)
42.2
Total Output (sgft/Ton)
284.5
Air System
CFM per System
4,000
Airflow (cfm)
4,000
Airflow (cfm/sqft)
1.41
Airflow (cfm/Ton)
402.0
Outside Air (%,)
23.7
Outside Air (cfm/sgft)
0.33
ote: values above given at ARI conditions
:ATING SYSTEM PSYCHROMETRICS
26.0 of 59.2 of
Outside Air
948 cfm
69.5 of
3.6 / 77.0 of
311�
Outside Air
948 cfm
75.3/62.3 of
SYSTEM
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK J
I COIL HTG. PEAK
CFM
I Sensiblel Latent
I I CFM
I Sensible
5,659
114,423
12,006
1,209
45,026
0
5,721
2,251
0
0
948
33,547
17,463
948
43,852
0
0
5,7211
2,251
159,4 29 469 93 380
CARRIER 50HJQ012 102,536 7,537 71,201
Total Adjusted System Output 102,536 7,537 71,201
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK I Jul 5 pm I I Jan 12 am
105.0 of
Heating Coil
Supply Fan
4000 cfm
105.0 of
—� Supply Air Ducts
104.5 of
ROOMS
70.0 of
�% Return Air Ducts 4
HROMETRICS (Airstream Temperatures at
83.2 / 66.2 of W 55.0 / 53.7 of
Cooling Coil Supply Fan
4000 cfm
55.0/53.7 of
—� Supply Air Ducts
56.3 / 54.2 of
50.5% R.H. ROOMS
74.0 / 61.8 of
EnergyPro 4.1 by EnergySoft User Number: 3358 Job Number. 06-002 Page:18 of 19
i
1� 9'
,HVAC SYSTEM HE AND COOLING LOADS SUMMARY „
PROJECT NAME .d DATE
Washington Park Subma'or 5 4/28/2006
SYSTEM NAME FLOOR AREA
RTU -4 3.045
Number of Systems
1
Heating System
Output per System
114,000
Total Output (Btuh)
114,000
Output (Btuh/sgft)
37.4
Cooling System
Output per System
119,400
Total Output (Btuh)
119,400
Total Output (Tons)
9.9
Total Output (Btuh/sgft)
39.2
Total Output (sgft/Ton)
306.0
Air System
CFM per System
4,000
Airflow (cfm)
4,000
Airflow (cfm/sgft)
1.31
Airflow (cfmlTon)
402.0
Outside Air (%)
25.5
Outside Air (cfm/sgft)
0.33
Note: values above given at ARI conditions
EATING S
26.0 of
1
Outs
1020 cfm
69.9 of
112.0 / 77.9 of
311�
Outside Air
1020 cfm
74.5/62.0 of
4.1 by
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
CFMI
Sensible
2,014
40,717
12,914
F 174
6,489
0
a
2,036
324
0
0
1,020
40,705
18,518
1,020
47,657
0
0
2,0361
324
85 545 31,432 54 795
CARRIER 50HJQ012 103,453 5,402 71,20
Total Adjusted System Output 103,453 5,402 71,201
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am
4YCHROMETRICS (Airstream Tei
58.7 of 105.0 of
Heating Coil
Supply Fan
4000 cfm
105.0 of
-� Supply Air Duct
104.9 of
ROOMS
70.0 of
Return Air Duct
drstream Temperatures at Ti
84.0 / 66.6 of M 55.0 / 53.7 of
User Number: 3358
Cooling Coil
Supply Fan
4000 cfm
55.0 / 53.7 of
4 Supply Air Ducts
55.5; 53.9 of
50.7% R.H. ROOMS
74.0 / 61.9 of
Return Air Ducts
Job Number: 06-002
19 of 19