Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FA2024-0008
BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT Qa�fra 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ta CALIFORNIA Permit Type: Fire Alarm/Monitoring System Owner: Permit Number: FA2024-0008 Applicant: Property Address: 79295 HIGHWAY 111 APN: 600340027 Contractor: Legal Description Parcel 1 PM 202/40 PM 30420 Property Zoning: CR, 1 Valuation: $1,000,000.00 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 07/02/2024 ISSUED DATE: 07/15/2024 Jared BOTTERON 16001 W 99th St, Lenexa, KS 66219 WACHTER INC / 812907 16001 W 99TH ST, LENEXA, KS 66219 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 3/19/26 5:05 pm Page 1 of 3 BUILDING PERMIT Permit Type: Fire Alarm/Monitoring System Permit Number: FA2024-0008 Property Address: 79295 HIGHWAY 111 REPLACE EXISTING FACP MAIN BOARD WITH NEW FACP MAIN BOARD (B9512G). INSTALL SIX (6) NEW NOTIFICATION APPLIANCE POWER SUPPLIES. INSTALL NEW NOTIFICATION APPLIANCES AND CIRCUIT WIRING THROUGHOUT STORE AS SHOWN. REPLACE TWO (2) EXISTING ANNUNCIATORS WITH NEW DEVICES (B926F). REMOVE EXISTING SP-T SURGE SUPPRESSOR REMOVE B430 AND PHONE LINES ADD NEW B444-V CELLULAR COMMUNICATOR ALL OTHER ALARM DEVICES ARE EXISTING -TO -REMAIN. Building/Unit M: Stores, Markets, Gas Calculated Occupancy 1200 Fire Alarm System - Alarm Central Occupancy Station Load Monitoring Company Classification(s) Name Monitoring Company 702 SE Fifth St. Monitoring Company 4792734600 Supervising Station Porprietary Supervising Address Bentonville, AR 72716 Phone Number Type Station UL CERTIFICATE # (if Zoning CR General Plan CG applicable): City Limits Within La Quinta Limits Subdivision Name PM 30420 Lot Number 1 Lot Size 110488 Centerlines 83863, 86301, 82915, Legal Description Parcel 1 PM 202/40 PM 83862, 86300, 82914, 30420 85297, 86878, 82916, 86302, 123848, 86877, 82913, 123856, 86087 Type Group Sq Ft Value Invoice No. Fee Fee Amount Amount Paid INV-00007889 Digital Archiving and Records Management Fee - OTC $12.00 $12.00 Fire - Alarm System $1,190.00 $1,190.00 Technology Enhancement Fee $8.00 $8.00 Credit Card Convenience Fee $30.25 $30.25 Total for Invoice INV-00007889 $1,240.25 $1,240.25 Grand Total for Permit $1,240.25 $1,240.25 Workflow Step / Action Name Action Tvoe Start Date End Date Printed: 3/19/26 5:05 pm Page 2 of 3 BUILDING PERMIT Permit Type: Fire Alarm/Monitoring System Permit Number: FA2024-0008 Property Address: 79295 HIGHWAY 111 Inspections v.1 09/20/2024 0:00 10/24/2024 17:08 24-H R Battery Test v.1 Inspection 10/15/2024 11:01 10/24/2024 17:01 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Alarm - Function Test v.1 Inspection 10/24/2024 17:00 10/24/2024 17:07 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Alarm Final v.1 Inspection 10/15/2024 11:03 10/24/2024 17:08 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Alarm Rough Wire v.1 Inspection 09/20/2024 0:00 09/27/2024 9:35 Linked Records v.1 07/02/2024 16:51 03/17/2025 9:23 ---------------------------------------------------------------------------------------------------------------------------------------- Linked Permits v.1 Create Sub Permit 07/02/2024 16:51 03/17/2025 9:23 Review v.1 07/02/2024 0:00 07/11/2024 15:47 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Review v.1 Receive Submittal 07/02/2024 0:00 07/11/2024 15:47 Revisions v.1 10/11/2024 0:00 10/23/2024 17:48 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Revision Review v.1 Receive Submittal 10/11/2024 0:00 10/23/2024 17:48 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 3/19/26 5:05 pm Page 3 of 3 CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT �Cv BILL WEISER - FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA CALIFORNIA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org July 11, 2024 Wachter Inc. 16001 W. 991h Street Lenexa, KS 66219 Re: Fire Alarm System — Walmart FA2024-0008 / 79295 Highway I I I The fire alarm system plan for the above referenced project was reviewed and approved with the following conditions. 1. The Office of the Fire Marshal staff shall conduct the following inspections: a) Rough -Wire Inspection — all wire not in conduit is exposed for inspection. b) Function Test / including 5 minutes of alarm on secondary power after a 24-hour period - The alarm installer shall provide all needed testing equipment to complete the final alarm inspection. 2. Certification of the system operational test shall be provided to the RVC-OFM Inspector before beginning the final acceptance test. After the final acceptance test, a copy of the Record of Completion shall be provided to the RVC-OFM Inspector and the property representative. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible for contacting the Fire Department to schedule inspections. Inspection requests are received through email: FireBusinessMailklaquintaca.gov All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox — Supervising Fire Marshal RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD CV t�u.KCV THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. — CALIFORNIA — INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79295 Highway 111 — Walmart PERMIT#: FA2024-0008 AT ED: 7/11/24 DESCRIPTION: Fire Alarm System CONTRACTOR: Wachter Inc. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final EF Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final EF SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections email: FireBusinessMail(a)laquintaca.gov B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 wa i 1111 1 VA. • I " SYSTEM RECORD OF COMPLETION (conflnuod) 9. NOTIFICATION APPLIANCE8 �y �a� D911ff1p1{On _ pe Audible �I 0 NIA Visible 61 WHOLE STORE Combination Audible and Visible S! WHOLE STORE 10, SYSTEM CONTROL FUNCTIONS Type _ Quantity Hold -Open Door Releasing Devices HVAC ShmdowTt vim'smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS lg This system does not have intereotmected systems. 0 Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: TYLER SANDER Date: 10/2412024 - ) C. Organization: WACHTER,INC Title: TECHNICIAN 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: TYLER SANDER Organization: WACHTERJNC Title: TECHNICIAN 123 Acceptance Test Date and time of acceptance test: 101242024,1156 PM Installing contractor representative: TYLER SANDER Testing contractor representative: TYLER SANDER a ✓� �� Property representative: AHJ representative: Phone: (479)879-7637 Date: 1 OI241202a I G Phone: (479)879-7637 e Copyright O 2012 National Fire Protection Auoelauum This form may be copied for individual use other than for male. It may not be copied for commercial sale or distribution. 6 rvQ■■■■%wa■ SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Crinfrnl Knit 5.1.1 Priannn• Power Input voltage of control panel: 16 4VAC Control panel rtmpc 0 33 A PRE Transformer, 2 4A poet transformer Overcurrent protection: 1),pe: BREAKER Amps: 20 Branch circuit disconnecting means location: EDC-t Numbs: 5.1.2 Second."' Power T\Tc of secondan• prover: 12V SLA BATTERIES Location. if remote from the plant: ALARM PANEL Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 5.2 Control Unit ❑ This system does not have power extender panels ® Potver extender panels arc listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level N Y g 100 Signaling Line g 100 Device Power N Y g 100 Initiating Device N Y g 100 Notification Appliance N y Other (specify): REMOTE ANNUNCIATORS Type SERVICE DESK RnSCH ra vF1iTIRULE ENTRNCE UPC ROOM Location 8. INITIATING DEVICES Addressable or r..__ nuantity Conventional Alarm or Manual Pull Stations I NIA Smoke Detectors N/A Duct Smoke Detectors N/A Heat Detectors N/A Gas Detectors N/A Watertlow Switches N/A m Taper Switches N/A Copyright ® 2012 National Fire Protection Association. This form may be copied for individual use other than for betide. It may not be copied for commercial sale or distribution. (11 2 Ct X ic W W 4 roon 0 0 0 E CA a %5 '40P SYSTEM RECORD OF COMPLETION This Dorm i.r to he completed by 1he.sR4rem ill allnllnrt contractor at the time oj.eyrlem acceptance and approval. Ir shall be permitted to modlfi, this farm as needed to provide a more complete andlor clear record. Afinelr nddltlonal sheets, dnfa,l or calc l tlonr at rneceavnry to provide a complete record Form Completion Dale: 10/24/2024 Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of pmlxry: WALMAR1 SIOREN1805 Address: 79-295 HWY 111,LA QUINTA,CA,92253 Description ofpmpery: RETAIL STORE Name of property representative: MANAGER ON DUTY Address: Phone: Fax: E-mail: 2, INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: WACHTER, INC. Address: 1419 W MONROE LOWELL, AR. 72745 Phone: 479-751-3600 Fax: E-mail: WACHTER ALARM@WACHTER COM Service organization: Address: Phone: Fax: E-mail: Testing organization: WACHTER, INC. Address: 1419 W MONROE LOWELL, AR. 72745 Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: WALMART ALARM CENTRAL Address: 702 SW 8" St, Bentonville, AR 72716-0770 Phone: 479-273-4600 Fax: E-mail: a.cserv@wal-mart.com Account number: F1555 Phone line l: Phone line 2: Means of transmission: Entity to which alarms are retransmitted: ALARM CENTRAL Phone: 479-273-4600 3. DOCUMENTATION On -site location of the required record documents and site -specific UPC ROOM software: 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: ❑ New system ® Modification to existing system NFPA 72 edition: 2022 Permit number: FA2024-0008 4.1 Control Unit Manufacturer: BOSCH Model number: B951 4.2 Software and Firmware Firmware revision number: CURRENT 4.3 Alarm Verification ® This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright 02012 National Fire Protection Association. This form may be copied for Indillft.1 use other than for resale. It may not be copied for commercial sale or disVibution. (p 1 of 3) N�i7O0i0r� � IE 29EZ6 VS6Z6L111 I.MH Sf aL� r �a H W �5.:saf O > O LLJ Ea°E- — Q Q �� m tx=gig z U wQ z w� u w U �O F-� w U - LLI w - - > >� QQ U - U W/I w U' >J n 3 n 3 OLO z O O� 00 z Q Q � J w =� z 00 Q O w X � W � w J w �cn w HWS �Q �w W Uw w� CO U U W Q �v � z Q o U � Q � TEv _rE mom" 091 :ON J�OiS �1111111111 J q m 3 IN x�¢ Z O aY n -%� a Oo£sw =8_€ 8a'ay z� :° '3w go��od� p `�'p I°p W_ £�� 5 0� ��opoo> _ awH K_ z. o o�wo��33aoWQ� 3�ao <o'<°�wmwo Hnia�o. o i O O E 3 W ] Pd O ° iOE 4 rOn - ow F qq44 5 �w Q a q2 33 o a� rco a �x I 1 1 1 I. 1 I i AG�OG�����C���CCC�110111 r^ x rE] 10 RQ X® .Q yiH �1 "£ T4, _® 79"'(D .7 ^® nO ^® C9 C9 x0 a ® ^O ^® ^O si' zoo x w o o .o '9d—� w� - pom g �O a9' a9' Q®Q ® 9A Jae far OO ;p 20 CD 9� . �i. CS e k® m B a E IRISSb d6 sgfe M k Y @@4 W f �B4y �� 1'§ d�3 �Wg gY3d 4�@ 6Y9g �°• ���� cwi a �sr a ssa !$: MI _ zi Q W E 1'€ A, w § o a gi�A 4= $�� €�b�B ���8 a ��I� S�� @ xw bw=a IH, a- as ®fir 2 ?_ axe@o w a£I y ,o 1H n as 9 ; Nil B$ g 1i:`o € d� wg ��B pea8g �d[� 41 YY@o 's fi r@ J 3 m q Z O 00 aY m7yad _%� o-o ph €�� F=B-z—:� £ sw z gmwS� aO o a o oGp K yoE� .gp sq°q°`» oa'�worc�3aowo 3a—'o ao'a CwmwO =mSFS3 3 z u O ; i zz ao z m o F m— w o F W 4o i ° ] O 4 lo rOn - x ow w� gz �w � �� o 33 rc> i 1 1 1 I. I I I I I j i I AG�OG�����C���CCC�110111 �1111111111 e A� Ap RD gip{ @g 4os O Ow,z _ a °W w a L� w W �F9 S081 3N J2OiS 11 vs vLNlno v o p ;e o,,,�=aa N 15�AIM S�Innn IS�I6 ZI�6�L m z y �'€0��8� Ul`O�Q� rw a r I I 1 1 i I IIIIIIIIIII �GDOG�IC���C���CCC�1O0111 O T (v yT IT WT „T T y�T y�Y® ^T ® gs gMT g+T gT O WT (V T g^T gas 0 .4 4 4.4a4.0 -4-0 + 0 4W+-4 40 04 4 4-0 a 4444 4i0g0A4 Iq14014 -0=4414 ; 444 MHO o 4o oo!� o -4o ok�o3� i 04-4 ; a0 41�40 ' I I I I I I I I I I I I I I I I i I I I I I i i I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I I I i I e g g g I I I g I I >f § zO xW jw ti 3 Q� a fd,�u� ZF�Bxomh€��o� LL�p »ww�3pK X po��„30� p=�yW6� z _ -�33z�'az ❑ W' oao5 3Wy�pLL W �azxuoam og a 030 - w a g�oSa =�po W Z. � F��3i�n ion !Z8. xZz �1111111111 .. -N=Y �1111111111= a CI ►m 0 mill I I I I 1 I I I I 1 I I I D0000��®�■®0000■■■■ OGDOG� ����C�CCC�100111 MINIMUM Ulu MUSEUM 8111111,1111 1818111, moppmpmppgmm 1■©■11 J z0 $ z w °� a �mw� z F�B`omN€��o� LL�p yiw -UNH X O iw'ofk'o�m° �� rc2S�yW°� w a gR Hpo rldz- 11111111111 W W z � � z o o LL W J J - O O Q _ - = Z n s p Q Q z z z -D ~ 0 ~ U IJ ~_ U�dw W U W - W Q 1. Q u W _01 W/J W^ >J v< <v / 3 i- - - - - - G �% OLo z � O O� 00 z z Q " Q J L-J _ z - v � --gip O w X o W -- z — w >-cn LLJ LLI LL Q w www W � > www � - U W W m =aE O � o(( a�Elocn �.�ao O LL LL �6` v� v E t o d 7 v N V O20 a O U� LLJ U Q � � v Q O O �_n U mE ego Q Ohv smaw Z mw I. aoO Z O LL u�a uy� py ��w wogw m 8 g MR 9aw x H-�' $m�o8 sF €'i m'w _q NF y m'a a 0, �oH�rc°��oo� wo��ippqmi wo'o i°' °LLB Q aw K oa'F E000SSkw CrSx ma�rc g5522iam H Qy `5 N_ _w`��i. € = f M OU � zm z _w z rco rc rc 3u i0 2 u� F-1I7 qqq�qqq®R9� III � �� �wb Ia9aIIIIhill� IIII�41,ll I�D�ILa�JL� L��J 11111111111 x® x0 x® .x'.. w 9d zoo C5 UOFO 13 o _Qo .o 0 0 O � , io O :Q 90 z 3� o ag age B� Z o O W Uz d �r UwOa w W `} � w a 11111111111 - 11111111111 _ .. la a$-ls9 p Z ULLOa a o -p °a �< m � SW5 Gm z „a _% z z-z� y �W E iw aw o=8 w R's-H! o ww ''� „ow - w aoof 9Qzap $a -z p�3z zE 0 K oNw poy £�� qz��°°dm a K K H gol o mw�rc Oa'�N ao 3 O oa'�wo �3 z,- Wok � z SFSz 3 z LL z m- w W 4° ° i ] O 4 OE rUn - x ow m 3 a gz tz,w sg k:� 0 I1Z 11111111111 .. Mimi I ;: as plU � pM ■■■■■■■■■■■ i S ® ® ® 0 ® ® ® S ® ® ® S ® ® ® 0 ® ® ® q � 4 0 y� H , 4 -q r 0 0 —4 4-400 ?�-q1�4 074?�4 �4-4-4 D40�0 4,44 4A4-7, q4-4 44 '+ 0q4- 004 -44-4 014414 oN W+ 0141414-041+0R4 : 4-0 4 4 ' 4-40� 0 44,� 0W+0 q4R� : 04-4 ; 0 0 4'4 1 404 I . . . . i 4 ! 4 -4 i : &4" ,J* POW &¢ 1 44 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I fi w 3 w 3 = 3 � LL� Z O <O Leg%gty,d '�"GS O qda Z c~iLLFa ww�4p. w a a ° gFoj ' H�=oo�o z.z so°Hw>g 3 oeo a�=,po o W a €aim wax_ tEM z 11111111111 .. M 1 - 11111111111 _ .. " mill I u M11 Millillillillilillillill 1818113 ©o0011 ©Mmm"m ,■©■„ EMM��©�©� ©©�MIS 3 x i ° ✓� o 0 LLOS., _ 5 N —.11 °m H H 0 rc Z. O <o Leity,d '�"GS O qda w �BNW - z c~i�o�gg a W'o w�ygwNQg� LLFa ww�4p. 3€r" w p a �a oko O g` a3O°�� z.z 3yy z=z O :fin a�O CN�a� osp�� LL ON-2821 ���twv3:��i. @oi�oosp�o 0 tel ian Engineering & Consulting CSFM's Walmart La Quinta, CA #1805 TELGIAN ENGINEERING & CONSULTING ENGINEERS O CONSULTANTS O ANALYSTS O ASSESSORS EMERGENCY MANAGEMENT & OPERATIONS CONTINUITY • ENGINEERING, DESIGN & CONSTRUCTION ENVIRONMENTAL, HEALTH & SAFETY • FIRE PROTECTION ENGINEERING • RISK MANAGEMENT & LOSS CONTROL • SECURITY RISK CONSULTING 900 Circle 75 Pkwy, Suite 680, Atlanta, GA 30339 www.telgian.com CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7165-1615:0251 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS 130 Perinton Parkway, Fairport, NY,14450 Contact: Namisnak, Peter (585) 678-3462 (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: Models B9512G and B8512G Fire Alarm Control Units. Inherently power -limited; remote station, central station and local service. Refer to listee's data sheet for detailed product description and operational considerations. System components: D122/D122L: Dual Battery Hardness D125B: Powered Loop Interface Module 13520: Auxillary Power Supply D129: Dual Class A Initiating Circuit Module D130: Relay Module D192G: Notification Appliance Circuit Module D1640: Class 2 Transformer D8004: Transformer Enclosure B299, D8125MUX: POPEX Module D8129: OctoRelay Module D8130: Door Release Module B901, D921013, D9210BC, D9210BLC, D9210C: Access Control Interface Module DX4020, B426: Network Interface Card ITS-DX4020-G: GPRS/GSM IP Communicator D9127T/D9127U: POPIT Module D8128D: OctoPOPIT Module D1255RB/D1256RB/D1257RB: Keypads/Annunciators B600, D8125: Zone Expander Module Page 1 of 3 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: INSTALLATION: MARKING: APPROVAL: NOTES: 13925F, 13926F, *B926M: Keypads D6600: Receiver 28010 (27 K Ohm)/15-03130-004(1 K Ohm)/15-03130-005(560 Ohm)/25899 (2.21 K Ohm)i: EOLR Resistors B8103, D8103/D8108/D8108A: Enclosures ICP-SDI-9114: SDI Splitter/Isolator Module B208: Input Module B308: Output Module DS7432, DS7457iF, DS7460i, DS7461 i, DS7465i: Multiplex Modules B440, B441, B443: Cellular Modules B450: Interface Module D8109, BAT13-40, BATB-80: Enclosures B430: Phone Module 120 VAC In accordance with the listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. *Models complies with the applicable requirements in UL 864, 10th Edition. *Revision 5-17-22 VWW This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an :.- endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Page 2 of 3 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Date Issued: 05/01/2023 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2024 Page 3 of 3 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7315-1335:0110 CATEGORY: 7315 - POWER UNITS LISTEE: Altronix 140 58th Street, Bldg A, Ste 2N, Brooklyn, NY,11220 Contact: Zatz, Gary (718) 567-8181 (718) 567-9056 Email: garyz@altronix.com DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTES: Model AL1002UL-ADA, NAC Power Extender, (Power Supply/Charger). Unit is a regulated 24 VDC 10A [in alarm] power supply/charger used for supervision and expanded power driving capability of up to four notification appliance circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. 115 VAC input, 24 VDC output In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction Listee's name, model number, electrical rating, and UL label. Listed as power supply unit for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. For fire alarm use, the secondary (standby) power supply shall supply energy during power loss to operate a protected premises, central station, or proprietary system for 24 hours or an auxilliary or remote station system for 60 hours in the normal condition followed by not less than 5 minutes of alarm as required by code. *Rev. 06-21-05 This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an :.- endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/04/2024 Listing Expires: 06/30/2025 Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7125-1653:0504 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: INSTALLATION: MARKING: APPROVAL: NOTES: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. "Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt 15T7�, This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test ~°"""`°•c results and/or other data but does not make an independent verification of any claims. This listing is not an :.- endorsement or recommendation of the item listed. This listing should not be used to verify correct operational `°-.,•..••mow requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2025 Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7135-1653:0503 CATEGORY: 7135 - AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W Page 1 of 3 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE RATING: INSTALLATION: MARKING: APPROVAL: NOTES: CeilingTrim Rings: *TRC-2 and "TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBCWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. 12 VDC regulated and 24 VDC/FWR In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and LIL label. Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21- 2017 dcc This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test ST•`•c results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational �RviG requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Page 2 of 3 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Date Issued: 05/03/2024 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2025 Page 3 of 3 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7167-1637:0506 CATEGORY: 7167 - CONTROL UNIT (HOUSEHOLD) LISTEE: Honeywell International Inc. One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa 8608059678 Email: lisa.brant@honeywell.com DESIGN: RATING: INSTALLATION: MARKING: Models MPIP21000 and MPIP3000U Combination Residential Fire and Residential/Commercial Burglary Control Panels. The MAXPROO Intrusion Series Control Panels provide integrated intrusion and access control functionality for applications ranging from small, standalone sites to large multi -site projects. The system is configured through MAXPROO Cloud and can be managed by the end customer using MAXPROO Cloud web. System Components: MPIEOP4 - Relay Module MPIE1084U - Zone Expander MPIPSU35 - Remote Power Supply MPIKTSMF and MPIKTSPRX - Arming Station Touchscreen Keypad MPICLTEU - LTE Module MPIDC1 - Door Control Module MPIBXM35P - Enclosure Refer to listee's data sheet for additional detailed product description and operational considerations. 110-230 VAC: 0.5 to 1.0 A In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE APPROVAL: NOTES: Listed as combination household fire and burglary alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Compatible Devices: Carbon Monoxide Detectors: System Sensor - Models C01224T and C01224TR (CSFM Listing No. 5278-1653:0219) Signaling Devices: Cooper Wheelock, Inc. - Model AS-121575W (CSFM Listing No. 7125-0785:0131) System Sensor - Models P2RK and P4RK (CSFM Listing No. 7125-1653:0188) Smoke Detectors: System Sensor- Models 2151 and 2151T (CSFM Listing No. 7272-1653:0122) System Sensor - Models 2W-B and 2WT-B (CSFM Listing No. 7272-1653:0152) System Sensor - Models 5193SD and 5193SDT (CSFM Listing No. 7272-1653:0210) Burglary and other non -fire functions were not examined. 1-19-21 VWW 15T7�, This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test :.°"""`°•c results and/or other data but does not make an independent verification of any claims. This listing is not an - endorsement or recommendation of the item listed. This listing should not be used to verify correct operational `°-.,•..••mow requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/03/2024 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2025 Page 2 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1653:0202 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc. 3825 Ohio Ave, St. Charles, IL, 60174 Contact: Brant, Lisa 8608059678 Email: lisa.brant@honeywell.com DESIGN: Models MDL3R and MDL3W Sync Modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: MARKING: APPROVAL: NOTES: 12 or 24 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as sync modules for use with separately listed compatible audible and audible/visual devices. 07-22-08 bh This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an :.- endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/30/2024 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2025 Page 1 of 1 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.: 7300-1615:0502 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: BOSCH SECURITY SYSTEMS 130 Perinton Parkway, Fairport, NY,14450 Contact: Namisnak, Peter (585) 678-3462 (585) 678-3263 Email: peter.namisnak@us.bosch.com DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTES: Models B444, B444-A, B444-V, *B444-A2, *B444-V2: Cellular Wireless Communicator Modules, transmits in 4G LTE wireless communication. These modules consist of a single printed wiring board that plug into the control unit board. They have a connection to an antenna to enable off premise cellular communication. The boards are identical except for that they employ different radio modules. *Models B444-A and B444-A2 operate on the AT&T wireless network. *Models B444-V and B444-V2 operate on the Verizon wireless network. Refer to listee's data sheet for additional detailed product description and operational considerations. 12 VAC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as cellular wireless communicator module transmission device for use with separately listed and compatible fire alarm control units. Acceptable for use as single communication path or multiple communications paths. Refer to listee's Installation Instruction Manual for details. *Models complies with the applicable requirements in UL 864, 9th Edition. *Rev. 4-18-23 DAL Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/24/2023 Authorized By: David Castillo, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2024 Page 2 of 2 0 tel ian Engineering & Consulting FIRE ALARM SYSTEM SUBMITTAL Walmart La Quinta, CA #1805 TELGIAN ENGINEERING & CONSULTING ENGINEERS 0 CONSULTANTS 0 ANALYSTS 0 ASSESSORS EMERGENCY MANAGEMENT & OPERATIONS CONTINUITY • ENGINEERING, DESIGN & CONSTRUCTION ENVIRONMENTAL, HEALTH & SAFETY • FIRE PROTECTION ENGINEERING • RISK MANAGEMENT & LOSS CONTROL • SECURITY RISK CONSULTING 900 Circle 75 Pkwy, Suite 680, Atlanta, GA 30339 www.telgian.com www.boschsecurity.com BOSCH Invented for life The B9512G Control Panel and the B8512G Control Panel are the new premier commercial control panels from Bosch. B9512G control panels integrate intrusion, fire, and access control providing one simple user interface for all systems. With the ability to adapt to large and small applications, the B9512G provides up to 599 individually identified points that can be split into 32 areas. The control panel can communicate through its built-in Ethernet port (not applicable to "E" control panels), or through compatible plug-in modules that can send events over the public switched telephone network (PSTN) or over cellular network communications. For users, programmable keypad shortcuts, situation sensitive on -screen help, and a bilingual user interface make system operation simple and easy. With the B9512G Control Panel, you can: ► Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three ► Provides up to 599 points using a combination of hardwired or wireless devices for installation flexibility, and up to 32 areas and 32 doors for up to 2,000 users P. On -board Ethernet port for Conettix IP alarm communication and remote programming, compatible with modern IP networks including IPv6/ IPv4, Auto-IP, and Universal Plug and Play ► Installer -friendly features for simple installation and communications, including plug-in PSTN and cellular communication modules ► Remote Security Control app which allows users to control their security systems - and view system cameras - remotely from mobile devices such as phones and tablets • Monitor alarm points for intruder, gas, or fire alarms. • Program all system functions local or remote using Remote Programming Software (RPS) or the Installer Services Portal programming tool (available in Europe, Middle East, Africa, and China) or by using basic programming through the keypad. • Add up to 32 doors of access control using the optional B901 Access Control Module. Optionally use the D9210C Access Control Interface Module for up to eight of the 32 doors. The B9512G is a direct replacement for previous control panel models D9412GV4, D9412GV3, D9412GV2, and D9412G. Functions Programmable outputs • Four alarm -output patterns • Programmable bell test 2 1 B9512G Control Panels Point response • Selectable point response time • Selectable EOL values and configuration Cross point capability • Fire alarm verification • Dangerous gas indicator includes carbon monoxide (NFPA 720) • Watch mode • 63 point profiles User interface • Supervision of up to 32 keypads • Custom keypad text is fully programmable through RPS or the Installer Services Portal programming tool (available in Europe, Middle East, Africa, and China) • Full function menu including customizable shortcuts • Authority by area and 32 character name for each user • 14 custom authority levels to restrict system features that each user can access • Programmable primary and secondary language by user and keypad • 12 available languages (any two can be concurrently used) User interface languages The following table shows the available languages per keypad type. B915/ B920 B921C B930 0940 B9151 W/ 8942/ 8942 W English ✓ ✓ ✓ ✓ ✓ Chinese ✓ ✓ Dutch ✓ ✓ ✓ ✓ ✓ French ✓ ✓ ✓ ✓ ✓ German ✓ ✓ ✓ ✓ ✓ Greek ✓ ✓ Hungarian ✓ ✓ ✓ ✓ ✓ Italian ✓ be ✓ ✓ ✓ Polish ✓ ✓ Portuguese ✓ ✓ ✓ ✓ ✓ Spanish ✓ ✓ ✓ ✓ ✓ Swedish ✓ ✓ ✓ ✓ ✓ Area configurations Link multiple areas to a shared area such as a lobby or common entryway. The shared area then automatically turns On (arms) when all associate areas are armed and turns Off (disarms) when any one associate area is disarmed. For higher security applications, the Area Re -Arm feature guarantees that areas are always rearmed, and are disarmed for no longer than a specific, configurable, amount of time (for example, service time). Custom functions For added convenience, the installer can program custom functions that allow customers to complete complex tasks with one simple action. For example, a custom function can bypass a group of points and arm the system, allowing the user to perform these functions with one easy command. Users can activate custom functions with a keypad, keyfob, token, or card, or the control panel can activate a function in reaction to a faulted point, or automatically through a scheduled event (SKED). Passcode security • Two -man rule. Requires two people with two unique passcodes to be present at the time of opening. • Early ambush. Allows users to verify that the facility is safe by requiring two passcodes. The control panel sends a duress event if the user does not enter the passcode a second time after inspecting the premises. • Dual authentication. Requires two forms of identification before processing certain system commands, including turning off the system and opening doors. A standard system user must have a passcode, a credential (token or card), and appropriate command authority permissions. Door control Using the B901 Access Control Module or D9210C Access Control Interface Module, the control panel provides a fully supervised access control solution. The solution offers 14 programmable levels of access authority. Authority for door access is controlled by the user level, the group of the user, the time of day, the door state, and the area armed (On/Off) state. Easy exit control The control panel changes from one On (armed) state to another without turning off (disarming) the system. For example, if you change the state from Part On (Perimeter Arm) to All On (Master Arm), the control panel complies and reports the change. Easy exit control reduces the number of keystrokes, simplifying system operation. Programmable passcode-controlled menu list Passcode-controlled shortcuts provide users only with the options and information pertinent to them, simplifying system operation. Flexible control The system provides the flexibility to choose added convenience or high security. For example, you can restrict to a keypad's immediate local area turning on (arming) and turning off (disarming) the system with a passcode, even if the user has access to other areas. This is particularly useful for high security areas, where a user may have access to the area, but would prefer to only turn off (disarm) the area individually rather than with the rest of the system. Monitor Delay/Delayed Response Create a special point profile that delays the reaction of a point for a specified time (up to 1 hour in minutes and seconds). This delay provides time for the specified condition to reset before activating any annunciation. The system can annunciate locally and send a report, if desired. When the system is armed, the point can respond like a normal point - providing dual functionality. Use this feature to ensure that perimeter doors have not been propped open, or to monitor critical areas such as computer rooms and safes, for example. System users The system supports up to 2,000 users. Each user can have a personalized passcode, a wireless keyfob, and an access credential to control the system. You can assign passcodes to one of 14 customized authority levels in each area that can be restricted to operate only during certain times. You can program a primary and secondary language for each user and by keypad (select from English, Chinese, French, Greek, Hungarian, Italian, Polish, Portuguese, and Spanish). The keypad changes to the user's programmed language when the user enters his passcode or holds the Help key. Route groups and destinations The control panel can send reports to four different route groups using one primary and up to three backup destination devices for each route group. Reporting capabilities The control panel has flexible communications for most central station receivers with reporting capabilities such as: • Individual point numbers • Opening or closing reports by user and area number • Remote programming attempts • Diagnostic reports Destination test It is possible to send test reports to each and all destinations within each route group. Communication formats The control panel sends reports in these formats: • Contact ID (PSTN) • Modem4 (PSTN) • Conettix Modem4 • Conettix ANSI-SIA Contact ID • ANSI-SIA DC-09 Notice UL and ULC LISTED applications ANSI-SIA DC-09 format is not available for UL and ULC LISTED applications. allotice For premises equipment used in the communication path, such as routers, use only UL listed equipment. IP communication The control panel can use IP to communicate with a Conettix D6600 or a Conettix D61001Pv6 communications receiver/gateway. Use one of the following for IP: • The on -board Ethernet connection (not applicable to "E" control panels) • Ethernet Communication Module: B426 • Plug-in cellular communicator: B440/B441/B442/ B443/B444/B444-A/B444-V Conettix IP communication provides a secure path that includes anti-replay/anti-substitution features, and enhanced security with up to AES 256-bit encryption (using Cipher Block Chaining (CBC)). The control panel supports Domain Name System (DNS) for both remote programming and central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination, and accommodates a simple solution for central station disaster recovery. The control panel supports both IPv6 and IPv4 networks. Communication paths The control panel accommodates up to four separate phone and four separate network paths to the central station receiver. When resetting alarms or turning a system on and off, the user is identified by name and number. Personal notification The control panel can send text messages and emails for personal notification over Ethernet or using a cellular communicator. You can configure up to 32 destinations using a combination of cellular phone numbers and email addresses. The control panel sends notifications in the user's programmed primary language. Bosch Remote Connect (Cloud) Remote Connect simplifies connections from RPS, and the Remote Security Control app, using Bosch Cloud services. This service creates a secure connection to the control panel without specific router settings or the need for a static IP address or DNS. Notice The Bosch Remote Connect service is not available in Europe, the Middle East, or Africa. Firmware updates Remote firmware updates are available. A wide variety of input options Each point: Single 1 kf), single 2 kf), dual 1 kO (1 kO + 1 kO), and No £OL (end -of -line) (EOL) resistor options (for on- board and B208 inputs) Programmable for Fire, Intrusion, Access, Gas, and Supervisory devices Supports hardwired and wireless devices Supports IP cameras by Bosch as point and output devices IP camera support The control panel can integrate directly with Bosch IP cameras, using them as fully supervised points and outputs. Integration of cameras allows the camera's video motion detection to activate points on the control panel. The control panel's virtual outputs can be configured to trigger camera actions, including sending video snapshots via email. Security and fire detection The control panel provides eight on -board points, and up to 591 additional off -board points (depending on model and expansion interfaces). You can program individual points to monitor some types of burglar alarms, fire alarms, and supervision devices. Event log The event log stores up to 10192 local and reported events. The event log includes time, date, event, area, point, and user. View the event log from a keypad or use RPS or the Installer Services Portal programming tool (available in Europe, Middle East, Africa, and China) to remotely retrieve event information. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. Scheduled events (SKEDs) The internal clock and calendar start individually scheduled events (SKEDs). SKEDs perform several functions such as turn on or off, relay control, or point bypassing. The control panel offers: • 80 scheduled events with up to 31 different functions • 32 opening windows and 32 closing windows • 32 user group windows • Day -of -week, date -of -month, or holiday only schedules • 8 holiday schedules of 366 days (leap year) Dual bus and SDI keypad retrofits The dual SD12 device bus design provides greater installation flexibility, such as bus isolation for Intrusion and Fire. To use popular SDI keypads (for example D1255 and D1260), program one of the two SD12 buses for SDI operation. ZONEX and POPEX retrofits To retrofit legacy Bosch control panels that use ZONEX and POPEX devices, the control panel is compatible with the B600 Retrofit (ZONEX) Module. The 8600 adds two ZONEX buses to the control panel which can connect to existing legacy point bus (POPEX) devices (for example, the D8125). Programming Installers can perform limited programming on -site with a keypad (critical parameters; such as account IDs, central station and RPS IP addresses and phone numbers, reporting formats, and more). They can also do full programming on -site or remotely (attended or unattended) with RPS. A programmable system passcode prevents unauthorized remote programming. Full programming is also possible with the web -based Installer Services Portal programming tool. The Installer Services Portal programming tool is available for panel firmware version 3.06 or higher. f Notice The Installer Services Portal programming tool is available in Europe, Middle East, Africa, and China. The following table shows the available languages for RPS and Installer Services Portal programming tool. Installer RPS RPS custom Services programming text* Portal programming tnoi English ✓ ✓ ✓ Chinese ✓ Dutch ✓ ✓ French ✓ ✓ German ✓ ✓ Greek ✓ Hungarian ✓ be Italian ✓ ✓ Polish ✓ Portuguese ✓ ✓ Spanish ✓ ✓ Swedish ✓ ✓ " RPS custom text is text, that can be entered in RPS and which will then be displayed on keypads and on the Remote Security Control app. Diagnostics Keypads, RPS and the Installer Services Portal programming tool (available in Europe, Middle East, Africa, and China) offer diagnostic help for monitoring and troubleshooting. The diagnostics features allow you to view the status of the wired and wireless devices. The features provide the status of the control panel and its connected devices, such as firmware version, power, and missing conditions. View the status of each area. Remote Security Control app The Remote Security Control app allows users to control their security systems remotely from their devices. Users can: • Turn their security system On or Off • Turn specific areas On or Off • Control outputs for applications such as lighting control • View live video from Bosch IP cameras • Grant access remotely by unlocking and locking doors The app requires the installing dealer to create a Remote Access Profile for users, and to install the profile on their devices. Bosch Video Management System integration With Bosch Video Management System (Bosch VMS) and an intrusion system, the VMS operator has a single user interface to monitor and control the intrusion system combined with video surveillance. With Bosch VMS and a control panel, the operator can, for example: • View videos triggered by intrusion events, including all relevant information such as areas, point, and user show in the display with the event. • View areas, points, outputs, and doors - with their statuses - on the Bosch VMS map, providing the exact location in the system. • Turn on (arm) and turn off (disarm) areas. • Bypass and unbypass points. • Lock and unlock doors (Bosch VMS 6.0 and higher). Requirements to integrate Bosch VMS with a control panel: • A licensed Bosch VMS system using Professional Editions v5.5 or higher or Bosch VMS Enterprise Edition v5.5 or higher. • Expansion license to integrate the intrusion control panel. One license needed per control panel. Order number MBX-XINT-xx for the expansion license added to a Bosch VMS base license. Refer to the Bosch Video Management Software product page on the Bosch website, www.boschsecurity.com. • Access to the control panel account and Remote Programming Software (RPS) and the Installer Services Portal programming tool (available in Europe, Middle East, Africa, and China). Region Regulatory compliance/quality marks USA ANSI- CP-D1.2010-ControlPanel Standard- SIA Features for False Alarm Reduction Australia ACM Regulatory Compliance Mark RCM Regulatory Compliance Mark RCM ACMA Europe CE EMC, LVD, RoHS USA UL Underwriters Laboratories UL UL 294 - Standard for Access Control Units and Systems Region Regulatory compliance/quality marks UL UL 365 - Police Station Connected Bur- glar Alarm Units UL UL 609 - Standard for Local Burglar Alarm Units and Systems UL UL 636 - Holdup Alarm Units and Sys- tems UL UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems UL UL 985 - Househoki Fire Warning Sys- tem Units UL UL 1023 - Household BurglarAlarm Sys- tem Units UL UL 1076 - Proprietary Burglar Alarm Units and Systems UL UL1610- Central Station Burglar Alarm Units UL UL 1635 - Standard for Digital Alarm Communicator System Units FM Central Station FM Local Protective Signaling FM Remote Station CSFM California State Fire Marshal FCC Part 15 Class B FDNY- CoA Fire Department of New York City [B9512G, B9512G-E, B8512G, B8512G-El Canada ULC Underwriters Laboratories of Canada ULC CAN/ULC 5303 - Local Burglar Alarm Units and Systems ULC CANJULC 5304 - Standard for Signal Re- ceiving Center and Premise Burglar Alarm ULC CAN/ULC S545 -Residential ire blam- ing System Control Units ULC CAN/ULC 5559 -Fire Signal Receiving Centres and Systems ULC ULC-0RD C1023 - Household Burglar Alarm System Units ULC ULC-0RD C1076 - Proprietary Burglar Alarm Units and Systems IC ICES-003 - Information Technology Equipment (ITE) Brazil ANATEL 04450-16-01855 [89512G, B8512G when used with B430 or B442 ] IENotice Not all products and features are available in all regions. Consult your local Bosch representative for availability details. 1 6 1 B-9512G Control Panels Compatible products Keypads B940W Touch screen KP, While (SDI2) B942/13942W Touch Screen Keypad (SDI2) B930 ATM Style Alphanumeric Keypad (SDI2) B926F Fire Keypad (SDI2) B925F Fire Keypad (SDI2) B921C Two-line Capacitive Keypad (SDI2) B920 Two-line Alphanumeric Keypad (SDI2) B915/99151 Basic Keypad (SDI2) D1255 Series Keypads D1260 Series Keypads D1256RB Fire Keypad D1257RB Remote Fire Alarm Annunciator Power D 164016.5 VAC 40 VA Transformer DE-45-18 Transformer D 126 Standby Battery (12 V, 7 Ah) 0 12 18 Battery (12 V, 18 Ah) D122 Dual Battery Harness D122L Dual Battery Harness with Long Leads Enclosures B8103 Universal Enclosure (White) D8103 Universal Enclosure (Gray) D8108A Attack Resistant Enclosure D810BA-CE Attack Resistant Enclosure with Built-in Transformer D8109 Fire Enclosure Accessories B56 Keypad Surface Mount Box B96 Keypad Trim Bezel B99 USB Direct Connect Cable BSO1-10 Interconnect wiring cables (pack of 10) D161 Dual Modular Telephone Cord (7 f) D162 Modular Telephone Card (2 it) D166 Telephone Jack (RJ31X) Detectors D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads F220-86PM/S 12/24 VDCAddressable Detector Bases with POPITs F220-B6 12/24 VDC Two -wire Base F220-B6R Standard 12/24 VDC Four -wire Base) F220-P Photoelectric Smoke Detector F220-PTH Photoelectric Smoke Detector with +135°F (+57°C) Heat Sensor F220-PTH Photoelectric Smoke Detector with +135°F (+57°C) Heat Sensor and Carbon Monoxide Sensors F220-B6C 12/24 VDC Four -wire Base with Auxiliary Form C Relay FCC-380 Carbon Monoxide Detector FCH-T320 Heat Detector FCP-OT320 Multisensor Detector Optical/Thermal FCP-0320 Optical Smoke Detector MX775i Addressable FIR Detector MX794i Long Range Multiplex PIR Detector MX934i Addressable PIR Detector MX938i Addressable PIR Detector ZX776Z PIR Detector ZX794Z Long Range PIR Detector ZX835 TnTech Microwave/PIR Detector ZX935Z PIR Detector ZX938Z PER Detector ZX970 PIR/Microwave Detector Bosch conventional detectors, including Professional Series, Blue Line Gent, Blue Line, Classic Line, Commercial Line, and Ceiling Mount motion detectors, as well as glass break, seismic, request-to-exil, photoelectric, heat, and smoke detectors. Modules B208 Octo-input Module B299 POPEX Module B308 Octo-output Module B426 Conettix Ethernet Communication Module B430 Plug-in Telephone Communicator B442 Conettix Plug-in Cellular Communicator (using GPRS) 8443 Conettix Plug-in Cellular Communicator (using HSPA+) 9444 Conettix Plug-in Cellular Communicator B444•A Plug-in cell module, AT&T LTE B444-V Plug-in cell module, Verizon LTE B450 Conettix Plug-in Communicator interface 8520 Auxiliary Power Supply Module 8600 Retrofit (ZONEX) Module 9810 wireless receiver (RADON) B820 SDI2 Inovonics interface Module B901 Access Control Module D113 Battery Lead Supervision Module D125B Dual Class B Initiating Module D126 Standby Battery (12 V, 7 Ah) D129 Class A Initiating Module D130 Auxiliary Relay Module D132A Smoke Detector Reversing Relay Module D133 Single Relay Module D134 Dual Relay Module D1B5 Reverse Polarity Signaling Module D192G Class "B", Style Y Bell Circuit Supervision D 1218 Battery (12 V.18 Ah) D8125 Addressable Expansion Module 08125MUX Multiplex Bus Interface D8128D OctoPOPIT Eight -point Expander D8129 Octo-relay Module D8130 Door Release Module D9127U/T POPIT Module DS7461i Single -zone Input Module DS7465i Input-output Module D92IOC Access Control Interface Module ICP-EZTS Cover and Wall Tamper Switch ICP-SDI.9114 SDI Splitter Applications Remote Programming Software (RPS or BPS -LITE) v6.03 and higher Installer Services Portal programming tool Bosch Video Management System v5.5 and higher Remote Security Control Conettix receivers (Managed and configured with Conettix D6200 Programming/ Administration Software v2.10) Conettix D6600 Communications Receiver/Gateway (with only D6641 line cards installed) with CPU version 01.10.00 Conettix D61001Pv6 Communications Receiver/Gateway with CPU version 61.10.00 Conettix D6100i Communications Receiver/Gateway with CPU version 61,10.00 RADION wireless from Bosch BB10 wireless receiver (RADION) RFBT-A/RFBT bill trap RFDL-II-A/RFDL-11 TriTech motion detector RFDW-RM-A/RFDW-RM recessed mount door/window contact RFDW-SM-A/RFDW-SM surface mount door/window contact RFGB-AJRFGB glass break detector RFKF-A/RFKF two -button keyfob RFKF-FBS-A/RFKF•FBS four -button keyfob RFKF•TBS-A/RFKF-TBS two -button keyfob RFPB-SB-A/ RFPB SB single -button panic RFPB-TB-A/RFPB-TB two -button panic RFRP-A/RFRP repeater RFSM-A/RFSM smoke detector RFPR-12-A/RFPR-12 PIR motion detector RFPR-Cl2-A/RFPR-C12 PIR curtain motion detector RFUN-A/RFUN universal transmitter Inovonics Wireless B820 SDI2 Inovonics Interface Module ENKIT-SDI2 S0I2 Inovonics Interface and Receiver Kit. Includes 9820 andEN4200 EN1210 Universal Transmitter (Single -input) EN 1210EOL Universal Transmitter with EOL Resistor EN121OW Door -Window Transmitter with Reed Switch EN1215EOL Universal Transmitterwith Wall Tamper, Reed Switch, and EOL Resistor EN1223D Water-resistant Pendant Transmitter (Double -button) EN1223S Water-resistant Pendant Transmitter (Single -button) ENI224.ON Multiple -Condition Pendant Transmitter EN1233D Necklace Pendant Transmitter (Double -button) EN12335 Necklace Pendant Transmitter (Single -button) EN12350 Beltclip Pendant Transmitter (Double -button) EN1235DF Fixed -location Transmitter (Double -button) EN1235S Beltclip Pendant Transmitter (Single -button) EN1235SF Fixed -location Transmitter (Single -button) 8 1 B9512G Control Panels EN1247 Glass -break Detector Transmitter EN1249 Bill Trap Transmitter EN1242 Smoke Detector Transmitter EN 1260 Wall Mount Motion Detector EN1261HT High Traff.c Motion Detector EN1262 Motion Detector with Pet Immunity EN1265 360° Ceiling Mount Motion Detector EN4200 Serial Receiver EN5040-T High Power Repeater with Transformer Technical specifications Properties Dimensions 10,625 in x 7.75in x 1.875 in (26 99 x 19.69 x 4.76 cm) Weight 1.95 Ibs (0.88 kg) Communications Ethernet 10/100full duplex (N/Afar"E"control panes) Environmental considerations Relative humidity 5%to 93%at+32°C (+90°F) Temperature (operating) 0°Cto+491C(+32"Fto+12(°F) Power requirements Current (maximum) Standby.180 mA Alarm: 260 mA Output (alarm) 2 A at 12 VDC Output (auxiliary, 1.4 A at 12 VDC nominal continuous power, and switched auxiliary combined) Voltage (operating) 12 VDC nominal Voltage (AC) 16.5 -18 VAC Wiring Terminal wire size 12 AWG to 22 AWG (2.0 mm to 0.65 mm) SDI2 wiring Maximum distance - Wire size (unshielded wire only): 7,500 ft (2,286 m) - 22 AWG (0.65 mm) Number of... Areas 32 Custom functions 32 Keypads 32 keypads, including 16 SDI keypads Events Up to 10,192 Passcode users 2DO0, plus 1 instalfer passcode Points 599 (B on -board, up to 591 off -board and virtual) Programmable outputs 599 (3 on -board, up to 596off -board and virtual) RF points 504 IP cameras 16 SKEDs C Ordering information B9512G IP control panel, 32 areas, 599 points Supports up to 599 points, 3 on -board outputs, and 32 areas for intrusion, commercial fire. On -board Ethernet. Order number B9512G EWE-GSERIE-IW 12mths wrty ext G Series panel 12 months warranty extension Order number EWE-GSERIE-IW B9512G-E Control panel 32 areas 599 points, no IP The 69512G-E is available only in kits. Order number B9512G-E EWE-GSERIE-IW 12mths wrty ext G Series panel 12 months warranty extension Order number EWE-GSERIE-IW Accessories B520 Auxiliary power supply module, 2A 12V Provides auxiliary power to 12 VDC devices or to SD12 modules. Order number B520 B208 SD12 8-Input Expansion Module Provides 8 programmable inputs. Order number 8208 B308 SD12 8-Output Expansion Module Provides 8 programmable relays. Order number B308 B901 Door Controller Fully supervised, addressable SD12/SDI bus device that allows access control integration for Bosch G and B Series Control Panels. Order number B901 B810 Wireless SD12 bus Interface Receives RF signals from RADION transmitters, repeaters, and glassbreaks. Operates at 433.42 MHz. For use with compatible SD12 bus control panels. Order number B810 D122 Dual battery harness, 17" 18AWG Harness with circuit breaker. Connects two batteries (in parallel) to a compatible control panel. Order number D122 D122L Dual battery harness, 35", 12V Harness with circuit breaker and leads measuring 35 in. (89 cm). Connects two batteries (in parallel) to a compatible control panel in a separate enclosure. Order number 0122L D126 Battery, 12V 7Ah A rechargeable sealed lead -acid power supply used as a secondary power supply or in auxiliary or ancillary functions. Order number D126 D1218 Battery, 12V i8Ah The D1218 is a 12 V 18 Ah sealed lead -acid battery with two bolt -fastened terminals. It is used for standby and auxiliary power. It connects to a compatible control panel using a D122 or D122L Dual battery harness. Order number D1218 D1238 BATTERY, 12V 38 AH A 12 V sealed lead -acid battery for standby and auxiliary power with two bolt -fastened terminals. Includes hardware for attaching battery leads or spade connectors. Order number D1238 D137 Accessory mounting bracket for enclosure Used to mount accessory modules in B8103, D8108A, and D8109 enclosures. Order number D137 D1640 Transformer plug-in, 16V 40VA System transformer rated at 16.5 VAC, 40 VA. Order number D1640 D1640-CA Transformer, plug-in, 16V 40VA, Canada For use in Canada. System transformer rated at 16.5 VAC, 40 VA. Order number D1640-CA D9002-5 Mounting plate, 6 location 3-hole, 5 pcs 5 pack of mounting skirts for 68103, D8103, DB108A, and D8109 enclosures. Each skirt can hold up to six standard 3-hole mounting modules. Order number D9002.5 D101 Enclosure lock and key set Short -body lock set with one key supplied. Uses the D102 01358) replacement key. Order number D101 D110 Tamper switch for enclosure, 2pcs Screw -on tamper switch that fits all enclosures. Shipped in packages of two. Order number D110 ICP-EZTS Dual tamper switch Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS B8103 Universal enclosure, white White steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Order number B8103 D8108A Attack resistant enclosure, large, grey Grey steel enclosure measuring 41.5 cm x 41.5 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and key set. Order number D8108A D8109 Fire enclosure, 16x16x3.5", red Red enclosure, 16in. x 16in. x 3.5in. (41cm x 41cm x 9cm), 16 gauge (1.5mm) cold -rolled steel, full-length hinge, D101F lock and 2 D102F keys, UL Listed for commercial fire/burglary applications. Order number D8109 D8004 Transformer enclosure kit, grey For applications that might require a remote transformer in an enclosure. Can be used with B Series control panels and D9412GV4/D7412GV4 control panels. Order number D8004 BATB-40 Battery box/enclosure, 22x21x7.25" 22 x 20.75 x 7.25" (56 x 53 x 18.5 cm). Holds two dry or wet cell batteries. Optional BATB-SHELF battery shelf increases number of batteries. Suitable for residential/commercial fire or burglary applications. Order number BATB-40 BATB-80 Battery box/enclosure, 22x21x7.25" 14 x 20.75 x 7.25" (36 x 53 x 18.5 cm). Battery box/ enclosure with shelf holds up to four dry or wet cell batteries. Suitable for residential/commercial fire or burglary applications. Order number BATE-80 B99 USB direct connect cable Male A to Male A USB cable for local programming of control panels with on -board USB ports. Order number B99 B915 Basic Keypad Two-line alphanumeric basic keypad with language function keys. Available languages: English, Chinese, Dutch, French, German, Greek, Italian, Hungarian, Polish, Portuguese, Spanish, Swedish. Order number B915 B9151 LCD keypad, icon keys, S012 Two-line alphanumeric basic keypad with icon function keys. Available languages: English, Chinese, Dutch, French, German, Greek, Italian, Hungarian, Polish, Portuguese, Spanish, Swedish. Order number B9151 B920 2 Line Alpha Numeric Keypad (SD12) Two-line alphanumeric keypad Available languages: English, Dutch, French, German, Hungarian, Italian, Portuguese, Spanish, Swedish. Order number B920 B921C Two-line Keypad w/Touch keys, Inputs Two-line alphanumeric keypad with inputs and capacitive touch keys in black. Available languages: English, Dutch, French, German, Hungarian, Italian, Portuguese, Spanish, Swedish. Order number 8921C B930 ATM Style -Alpha Numeric Keypad (SD12) Five -line ATM style alphanumeric keypad Available languages: English, Dutch, French, German, Hungarian, Italian, Portuguese, Spanish, Swedish. Order number B930 B940W Slim Touch Keypad SD12 compatible touch screen keypad with function keys. Available languages: English, Chinese, Dutch, French, German, Greek, Italian, Hungarian, Polish, Portuguese, Spanish, Swedish. Order number B940W B942 Touch Screen KP Prox/Input/Output, black Black SD12 touch screen keypad with inputs and one output. Available languages: English, Chinese, Dutch, French, German, Greek, Italian, Hungarian, Polish, Portuguese, Spanish, Swedish. Order number B942 B942W Touch screen KP, prox/Input/output,white White SD12 touch screen keypad with inputs and one output. Available languages: English, Chinese, Dutch, French, German, Greek, Italian, Hungarian, Polish, Portuguese, Spanish, Swedish. Order number B942W B925F Fire and Intrusion keypad, S1312 Two-line alphanumeric fire and intrusion keypad. Order number B925F B926F Fire keypad, SD12 Two-line alphanumeric fire keypad Order number B926F B426 Ethernet Communication Module Supports two-way communications over Ethernet networks for compatible control panels Order number 8426 B442 Plug-in cellular module, GPRS Multi -function cellular communicator that provides IP communication over a (GPRS) cellular network Order number B442 B443 Plug-in Cellular, HSPA+ (3G+) Multi -function 3G/4G cellular communicator providing IP communication over a GPRS/EDGE/UMTS/HSPA+ cellular network Order number B443 B444 Plug-in cellular module, VZW LTE, hot Pre -activated 4G LTE cellular communicator for secure two-way IP communication on the Verizon Wireless LTE network. Order number B444 B444-C Plug-in cell module, VZW LTE, cold Non -activated 4G LTE cellular communicator for secure two-way IP communication on the Verizon Wireless LTE network. Order number B444-C B444-A Plug-in cell module, AMEC LTE This communication module provides secure two-way IP communication on North American wireless networks. Order number B444-A B444-V Plug-in cell module, VZW LTE This communication module provides secure two-way IP communication on the Verizon Wireless network. Order number B444•V 111 B9512G Control Panels Software Options D550OC-USB Kit with DVD and USB security dongle Remote Programming Software (RPS) with USB security key (dongle). Europe, Middle Eaap AM — Bosch Secmlty systems B.V P O Boc 80002 56W JB Emdhoyen. The Netherlands Phone; . 31 40 2577 284 arose seuvntysritems®Iwschcom emeaboschse"rlty tam Garrnansn Boxh Skherhellssysteme GmbH Robert -Bosch -Ain 5 85630 Grasbrunn Germany —bosch—rity Co. c Bosch 5,—Ity Systems 20191 Data subjact to change without otl- 13825787531 ( en, V36. 18. Oct 2019 Order number D550OC-US13 North A ..— Bosch Se —ray Systems. Inc 130 Perinton Parkway Falrport. New York 14450, USA Phone: •1 B00 2" D096 F— -1 $95 223 9180 ontinehetp®us.bouh com — boschs—rlty.us Robert Borth (SEA) Pie Lid, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: •858571 2808 F.:.85 6571 2699 i p r s etu r l tri yf t a m s �t>o s rr m m wwwboschsecu rlty.me hL II - mill www.boschsecurity.com 0 BOSCH Invented for life The B926F Fire Keypad is a fully supervised SD12 device for fire applications. Each keypad has user -adjustable backlit keys, a display that shows system messages, and a sounder. The sounder emits distinct condition tones to alert you to a fire alarm, a fire trouble, or fire supervisory events as they occur. The keypad includes fire status indicators and fire function keys. LCD display The keypad uses words, numbers, and symbols to show the status of the security system. When several events occur, the keypad shows each event in order of priority. Keys Each keypad has 10 number keys and 5 navigation keys. When pressed, keys turn on keypad backlighting and emit the keypress tone (short beep). The keypad has 4 Fire function keys: • ACK. Press to acknowledge the system alarm or trouble condition. • SILENCE. Press to silence fire alarms or troubles. ► Fire keypad with fire function keys: ACK, SILENCE, RESET, and DRILL ► 2-line LCD display with up to 32 character point, user, and area names ► Simple menu -style user interface with dedicated function buttons for common commands, including status indication ► Quickly identifiable, visual indicators for critical system statuses ► Simple installation with self-locking base and chassis design, plus built-in bubble level • RESET. Press to reset devices such as smoke detectors, and clear restored points. • DRILL. Press and hold to initiate a fire drill. Audible tones The keypad has a built-in sounder that produces several distinct warning tones. The tones are differentiated so that the user can recognize an event simply by hearing its associated tone. Status indicators The status indicators on the keypad provide a quick visual reference for system status. The Indicator lights when the system Is ready to turn on (arm) Theindicator lights when the system is on (armed). The indicator lights when dangerous gases are present including carbon monoxide (NFPA 720). The indicator lights when the system has power. Fire status indicators In conjunction with the display and status indicators, the fire keypad includes Fire status indicators. 6 The indlcator lights when a fire alarm condition exists. The indicator lights when a user silenced a fire alarm condition <o The indicator lights when a supervisory point is not normal. The indicator lights when there is a trouble condition Region Certification USA ANSI/ CP-01.2010•Control Panel Standard - 51A Features for False Alarm Reduction Region Certification USA UL UL 365 - Police Station Connected Bur - Oar Alarm Units UL UL 609 - Standard for Local Burglar Alarm Units and Systems UL UL 636 - Holdup Alarm Units and Sys- tems UL UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems UL UL 985 - Household Fire Warning Sys- tem Units UL UL 1023 - Household Burglar Alarm Sys- tem Units UL UL 1076 - Proprietary Burglar Alarm Units and Systems UL UL 1610 - Central Station Burglar Alarm Units CSFM California Office of The State Fire Mar- shall Canada ULC CANJULC5303- Local BurglarAlarm Units and Systems ULC CAN/ULC S304 - Standard for Signal Re- ceiving Center and Premise Burglar Alarm ULC CAN/ULC 5545 - Residential Fire Wam- Ing System Control Units ULC ULC-ORD C1023 - Household Burglar Alarm System Units ULC ULC-ORD C1076 - Proprietary Burglar Alarm Units and Systems Ic VonTechnology Equipment {ITE)f� Mounting considerations Mount in indoor dry locations. Power supply A compatible control panel supplies the power and data requirements to the keypad through a four -wire connection. Enclosure and wiring The sliding self-locking enclosure has an integrated bubble level and custom gap -free, lift -gate style terminal blocks to make installation easier. Materials and hardware features Dimensions 158 mm x 120 mm x 26 mm (6.2 in x 4.7inx1in) Weight 11.3 oz 10.32 kg) Material Acrylonitrile butadiene styrene (ABS) Poly(methyl methacrylate) (PMMA) Display window 2line display 18 characters per line Indicators illuminated keys Status indicators Warning and Indicating tones Power requirements Current Standby: 35 mA Alarm: 70 mA Voltage (input) 12VDCnominal Environmental considerations Relative humidity 5%to 93% at +32'C (+90'F) Temperature (operating) O'Cto+49'C(+32'Fto+12(rF) Wiring Terminal wire size 1.02 mm (18 AWG) to 0.65 mm (22 AWG) SD12 wiring Maximum distance - wire size: 260 m (850 ft) - 0.65 mm (22 AWG) 305 m (1000 ft) -1.02 mm (18 AWG) Compatibility Control panels B9512G/B9512G-E B8512G/BB512G-E B926F Fire Keypad Two-line alphanumeric fire keypad Order number B926F Accessories B56 Keypad Surface Mount Box Surface mount box for mounting a keypad to concrete or block. Order number B56 3 1 B926F Fire Keypad 896 Keypad Trim Bezel Cover the wall footprint of previous keypads when replacing them with the new, slim design of B Series keypads. The white trim bezel is 8.6 in x 6.3 in x 0.12 in (22 mm x 16 mm x 3 mm). Order number B96 Riipm-ted byr A—ricaat E—p., Niddk East. AM.. AalrPaelNa Ctunat A.-d— Latina, Bosch Security Systems, Inc Bosch Securoy Systems B.V as Robert Bch ISEA) Pie Ltd Security Bosch IShanahail Security Syttems Ltd. Robert Bosch Uda Security Systems D.—I.h I30 Pennton Parkway P O. Bar B0002 Systems 203 Building, No 333 Fupuan Road Via Anhanryera. Km 98 Fairport, New York, I4450. USA 5617 BA 6ndhwm, The NetWI-1s 11 &shah Street 21 North IBP CEP 13D85.900 Phone:.1 800 289 0096 Phanc • 3140 2577 294 SmpPar• 573943 ChanIInin6 District Shanghai C—Pmas. Sao Paulo, Braid Fax: •1 5B5 223 9180 Far -31 40 2577 330 Phone •65 6571 2808 200335 China Pnone: •55 19 2103 2860 security Wesous. bosch.cam •mN.)eNntysysterrma®bctch cam F.: -65 6571 2699 Phone •66 21 22181111 F.: •55 19 2103 2862 vvww baschsecunty. us www. baschs—ttycorm apr secuntysystemieboach.com Fa. •86 21 22182398 Iatam bo/chtecuntyabosch.com www bosch)ecunty.asta www boschsecunty c—cn www boschsecuriry com o Bosch Secunty Systems 2016 1 Data subject to change without notice 18689434123 1 en, VS. 22. Jan 2016 A ltronix© AL1002uLADA ' NAC Power Extenders Rcv AL10021:LAAA 090402013 Overview ALI002ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories. Specific Agency Listings: • UL Listed Control Units for Fire Protective Signaling Systems (UL 864). • MEA - NYC Department of Buildings Approved. • CSFM - California State Fire Marshal Approved. • FM - Factory Mutual Approved. • NFPA 72 Compliant. Input: • Power input 120VAC 60 Hz, 5 amp. • Two (2) Class A, Style Z or two (2) Class B, Style W, Y FACP inputs. • Two (2) NC dry contact trigger inputs. Output: • Class 2 Rated power limited outputs. • 24VDC @10 amp max total alarm current • 2.5 amp max current per output. • Separate 1.0 amp auxiliary output. • Programmable supervised indicating circuit outputs: Four (4) Class B, Style W, Y or Two (2) Class A, Style Z or One (1) Class A, Style Z and Two (2) Class B, Style W, Y • Thermal and short circuit protection with auto reset. Battery Backup: • Built-in charger for sealed lead acid or gel type bat- teries. • Automatic switchover to stand-by battery when AC Fails. • Zero voltage drop when switching over to battery backup. rations Supervision: • AC fail supervision (form "C" contact, 1 amp/ 28VDC). Factory set for 30 seconds with optional 2.5 to 3 hour delay setting (field selectable). • Instant local AC trouble reporting relay (form "C" contact, 1 amp 28VDC). • Battery presence and low battery supervision (form "C" contact, 1 amp 28VDC) Visual Indicators: • Input and output status LED indicators Special Features. • 2-wire horn/strobe Sync mode allows audible notification appliances (homs) to be silenced while visual notification appliances (strobes) continue to operate. • Sync protocols include Potter/Amseco, Faraday, GentexT, System Sensory, and Coop erWheel ock%. • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). • Compatible with 12VDC or 24VDC fire panels. • Output loop supervision steered to input 1 or input 2. • Signal circuit trouble memory (helps identify intermittent loop problems). • Common trouble input and output • Ground fault detection. • Unit includes power supply, red enclosure, cam lock, and battery leads. Mechanical: • Enclosure Dimensions (H x W x D approx.): 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm) • Product weight (approx.): 12 lbs. (5.44 kg). • Shipping weight (approx.): 13.3 lbs. (6.03 kg). Agency Approvals U�UL Listed Control Units and Accessories for Fire Alarm Systems (UL 864) Ninth California State Fire Marshal Approved. Edition FM Factory Mutual Approved. "EANYC Department of Buildings Approved. <pet>M PP Enclosure_ Dimensions (H x W x D approximat& 15 5" x 12" x 4.5" (393.7mm x 304.8mm x 114 3mm 45, 0 0 0 0 0 °0°0°0°0°0 °0°0°0°0 0 °0°0°0°0°0 °0°0°a°0°0 0°0°0°0°0 0 0 0 0 0 , ,- CA I—$ , O- CAr1 s o- M,n—, Honeywell FarenhytT"" Series THE POWER OF CONNECTED L-Series Indoor Strobes, and Horn Strobes for Ceiling Applications The L-Series audiblevisible notification products offer the most versatile and easy -to -use product line of horns, strobes, and horn strobes in the industry. This product includes lower current draws and modern aesthetics design which reduces installation times and maximizes profit. In adition, the L-Series offers white and red plastic housings, and wall and ceiling mounting options. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time consuming ground faults. To simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. FEATURES & BENEFITS • Listed for ceiling mounting only • Features a plug-in design with minimal intrusion into the back box • Designed with tamper -resistant construction • Rotary switch for horn tone and two volume selections • Tamper -resistant construction • includes a universal mounting plate for ceiling units • Produces horn rated at 88+ d BA at 16 volts • Rotary switch for horn tone and two volume selections • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150,177 • Contains a mounting plate with a shorting spring feature checks wiring continuity before device installation • Compatiblewith System Sensor synchronizaiton protocol V • Supports electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices L-SERIES SPECIFICATIONS ARCHITECT/ ENGINEER SPECIFICATIONS GENERAL L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or doublegang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 1 7/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuitr" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. STROBE The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and complywith the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model_ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and complywith the Americans with Disabilities Act requirements forvisible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporalthree pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync- Circuit model MDL3 listed to UL464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL Ceiling -Mount Dimensions (including lens): 6.8" diameter x 2.5"H (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW): 6.9" diameter 3.4"H (175 mm diameter 86 mm ELECTRICAL Nominal Voltage: Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range': 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge: 12 to 18 AWG ENVIRONMENTAL Standard Operating Temperature: 320Fto 120OF (0°C to 49°C) Humidity Range: 10 to 93% non -condensing Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12V nominal only for 15 and 30 cd AGENCY LISTINGS AND APPROVALS UL: Listed FM: Approved CSFM: Listed UL MAX STROBE CURRENT DRAW (mA RMS) CANDELA 8-17.5V 16-33V FWR DC DC 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 1 N/A 1226 264 UL MAX CURRENT DRAW (mA RMS), 2-WIRE HORN STROBE CANDELA 8 VDC 16 VDC 15 30 15 30 75 95 115 150 177 EM Temp Hi 103 167 71 90 143 165 187 217 254 EM Temp Low 96 165 54 71 137 161 185 211 249 EM Cont Hi 106 173 71 90 141 165 187 230 273 EM Cont Low 95 1166 54 71 124 161 1170 216 258 3.1KTemp Hi 111 164 69 94 147 163 184 229 257 3.1KTemp Low 103 163 54 88 143 155 185 212 252 3.1K Cont Hi 111 172 169 94 144 164 202 229 271 3.1K Cont Low 103 169 54 188 1131 155 187 1217 1259 CANDELA 16V FWR 15 107 78 107 78 108 79 108 79 30 135 101 135 1101 135 101 135 101 75 179 151 179 151 179 150 179 1150 95 198 172 198 172 200 171 200 1171 115 223 199 223 199 225 196 225 196 150 254 229 254 229 255 229 255 229 177 286 262 286 1262 289 260 289 260 EM Temp Hi EM Temp Low EM Cont Hi EM Cont Low 3.iKTemp Hi 3.1KTemp Low 3.1K Cont Hi 3.1K Cont Low HORN AND HORN STROBE OUTPUT (DBA) SWITCH POSITION SOUND PATTERN DB 8-17.5V 16-33V FWR DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 190 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal I High 184 189 89 8 3.1 KHz Non -Temporal Low 77 83 83 SL-SERIES DIMENSIONS me-861 2.47 CEILING -MOUNT HORN STROBES ORDERING INFORMATION CEILING HORN STROBES PC2RL: 2-Wire, Horn Strobe, Red PC2WL: 2-Wire, Horn Strobe, White i 6.92 CEILING BACK BOX SURFACE MOUNT BACK BOX CEILING STROBES SCRL: Strobe, Red SCWL: Strobe, White SCWL-CLR-ALERT: Strobe, White, ALERT ACCESSORIES TR-2: Universal Wall Trim Ring Red TR-2W: Universal Wall Trim Ring White SBBCRL: Ceiling Surface Mount Back Box, Red SBBCWL: Ceiling Surface Mount Back Box, White For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Farenhyt 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 351575 1 Rev B 1 02/18 9 2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor' and Honeywell* are registered trademarks of and FarenhytT" is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up -to date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call800-446-6444. Honeywell O,�� SYSTEM � SENSOR - Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING L FM MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189 (horns, chimes) f o m S y s t e m S e n s o r SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an O-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature —40oF to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL .. . 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 it 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with 8-175 16-33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 wc Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diaqrams 2.5" 3- Wall-Mount Horn Strobes 'a erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ©2012 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoncom SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,AVDS01 Di201 heiatestversionof his data sheet. S0101 • 3/12 www.boschsecurity.com (4 BOSCH Invented for life The D9127 Series POPIT Modules includes the D9127T (with magnetic tamper switch) and the D9127U (without tamper). They are used with a D8125 or B299 Addressable Expansion Module when there is a need to expand a compatible control panel beyond its standard number of on -board initiating zones or points. Future system expansion is very economical as D9127 Series POPITs can be added anywhere along the two -wire data expansion loop from the D8125 or B299 modules. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 1<0 end -of -line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. ► Provides point identification of initiating devices ► Supervises wiring to devices for circuit integrity ► Expands the number of points in the system ► Compact size ► Terminal connections for reliability Region Regulatory compliance/quality marks USA UL UL UL 365 - Police Station Connected Bur- glar Alarm Units UL UL 464 - Standard for Audible Signal Ap- pliances UL UL 609 - Standard for Local Burglar Alarm Units and Systems UL UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems (loth edition) UL UL 985 - Household Fire Warning Sys- tem Units (6th edition) UL UL 1023 - Household Burglar Alarm Sys- tem Units UL UL 1076 - Proprietary Burglar Alarm Units and Systems UL UL1610- Central Station Burglar Alarm Units UL UL 1635 - Standard for Digital Alarm Communicator System Units Region Regulatory compliance/quality marks Wiring Considerations FM Wire Size Maximum Length of all Data Expansion Loops Combined CSFM California State Fire Marshal 0.8 mm (22 AWG) 549 m (1800 ft) FDNY- 6059 [D9412GV3 & D7412GV3] CoA 1.0 mm (20 AWG) 881 m (2890 ft) FDNY- 6286 D7412GV4 D9412GV4 NYC COA 1.2 mm (18 AWG) 1402 m (4600 ft) CoA 6286 2018-2021 FDNY- 6196 1.5 mm (16 AWG) 2231 m (7320 ft) CoA 1.8 mm (14 AWG) 3551 m (11650 ft) Australia CTICK C-Tick D8125 or B299 POPIT Loops Canada ULC CAN/ULC S304- Standard for Signal Re- Use one two -wire data expansion loop, or distribute a mgCenterantlPremiseBurglar Alarm Alarm the POPITs on multiple loops. The maximum lengths shown in the following table are for all data expansion ULC S303-Local Burglar Alarm Units and loops combined connected to the same D8125 or Systems B299 module. Setting DIP switches on the POPIT ULC ULC 365- Police Station Connected Bur- modules assigns them to point numbers. The switch glar Alarm Units setting on each POPIT assigns it a point number, ULC APOUTS1871 Proprietary Alarm Units regardless of its physical location. Certified for Canada POPIT to Sensor Loops ULC ULC-ORD C1023 - Household Burglar The number of detection devices each sensor loop can Alarm System Units supervise is limited only by the resistance on the loop. Resistance on each sensor loop must be less than ' igu ration notes 100 0 not including the end -of -line (EOL) resistor. Compatibility Information Certain UL and National Fire Protection Association (NFPA) applications can limit the number of detection Control Panels All G Series control panels, D9412, D7412, devices. Consult the appropriate UL or NFPA D7212, D7212131, D9112, D9112131, standards. D8112G1, D8112G2, and D9124 Terminate each POPIT sensor loop with the 33 kQ EOL Modules D8125, B299 resistor included with each POPIT. Use a twisted -pair wire (six twists per foot) in all The D8125 or B299 POPEX Modules are required. The POPIT installations for both the data expansion loop D9127 modules are wired in parallel on the D8125 or wiring and the POPIT sensor loops. Run wires away B299 data loops. from AC sources to prevent AC induction. Number of POPIT Modules per Control Panel D7212G, D7212GV2, D7212GV3 32 D9127 POPITs Environmental Considerations D7212B1 40 D9127 POPITs Relative humidity Up to 93% non -condensing D7212, D7412, D7412G, D7412GV2, 67 D9127 POPITs D7412GV3, D7412GV4 Temperature 0°C to +60°C (+32°F to +140°F) (operating) For UL Certlfcatedlnstallatlons, O'Cto +50'C D9124 119 D9127 POPITs (+32'Fto +12.70 D9112B1 126 D9127 POPITs Properties D9112, D9412, D9412G, D9412GV2, 238 D9127 POPITs Color Off white D9412GV3,D9412GV4 B8512G (D8125) 67 D9127 POPITs Dimensions 8.1 cm x 3.8 cm x 2.4 cm (3.2 in. x 1.5 in. x 0.9 in.) B8512G (B299) 91 D9127 POPITs Material UL Listed fire-resistant B9512G (D8125) 238 D9127 POPITs B9512G (B299) 591 D9127 POPITs Power Requirements Current draw 0.8 mA maximum Resistance Maximum increase in resistance on the POPIT loop is 1000 0. Maximum resistance between the D8125 or B299 modules and each POPIT is 90.0. Voltage (operating) 12 VDC nominal Sensor Loop Resistance Maximum resistance on the sensor loop is 1000. Responsetime 1 sec approximately Represented by Europe, Middle East, Africa: Germany: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH P.O. Box 80002 Robert -Bosch -Ring 5 5600 JB Eindhoven, The Netherlands 85630 Grasbrunn Phone: + 3140 2577 284 Germany emea.securitysystems@bosch.com www.boschsecurity.com emea. boschsecu rity.com © Bosch Security Systems 2020 1 Data subject to change without notice 2538178443 1 en, V15, 25. Jun 2020 D9127T POPIT input module with tamper Includes a magnetic tamper switch. Order number D9127T D9127U POPIT input module without tamper No tamper switch. Order number D9127U D9127T-CHI POPIT input module with tamper Includes a magnetic tamper switch. Order number D9127T-CHI North America: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Asia -Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www. boschsecu rity.as i a www.boschsecurity.com BOSCH Invented for life F,b\-] 4d0 ► 3-hole mounting footprint and compact size allow for easy installation ► Provides legacy ZONEX input/output support a Compact size ► Includes two ZONEX busses allowing for continued ZONEX support on a compatible control panel The B600 Retrofit (ZONEX) Module communicates to Certifications and approvals the control panel through a proprietary connection, and provides support for two ZONEX busses. Connect Region Gettiffcatf� the B600 module to the control panel through a proprietary connection. USA UL System UL UL 1023 -Household Burglar Alarm Sys- ' tem Units Each module installs in the control panel enclosure or UL UL1076- Proprietary Burglar Alarm in an adjacent approved enclosure. Each ZONEX bus Units and Systems supports up to 15 D8128D modules, and/or up to UL UL 1610 -Central Station BurgiarAlarm D8129 Octo-relay modules. D8128D and D8129 Units modules can be combined on a single ZONEX bus. UL UL365-Police Station Connected Bur - Total number of modules cannot exceed 15 modules. ear Alarm Units Using your existing terminal block wiring strip, UL UL609- Standard for Local Burglar retrofitting your current ZONEX devices for use on Alarm Units and Systems your new control panel is effortless and easy. Simply remove the existing ZONEX terminal strip from your UL UL636-Holdup AlarmUnits and Sys - current control panel, and insert onto the B600. tems UL UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems The B600 Retrofit (ZONEX) Module gives you the UL UL965-Household Fire Warning Sys - tem Units flexibility to continue using legacy ZONEX products with either the B9512G or B8512G control panels. UL UL294- Standard for Access Control Units and Systems UL UL 1635 - Standard for Nital Alarm Communicator System Units 2 18600 Retrofit (ZONEX) Module Region Certification CSFM Calitomia State Fire Marshal (see our website) FCC Part 15 Class 8 Canada ULC ULC CAN/ULC S303 - Local Burglar Alarm Units and Systems ULC CAN/ULC S304 - Standard for Signal Re- ceiving Center and Premise Burglar Alarm ULC CAN/ULC S545 - Residential Fire Warn- ing System Control Units ULC ULC-ORD C1023 - Household Burglar Alarm System Units ULC ULC-ORD C 1076 - Proprietary Burglar Alarm Units and Systems IC ICES-003-Information Technology Equipment (ITE) Installation/configuration notes Mounting Mount the module into the enclosure's 3-hole mounting pattern using the mounting screws and mounting bracket. Wiring Use the control panel SD12 terminals labeled R, Y, G, B (PWR, A, B, COM) when wiring to the module. Connect the control panel terminals to the module terminals labeled R, Y, G, B (PWR, A, B, COM). You can also use the SD12 interconnect cable. Compatibility Control panels B9512GjB9512G-E B8512G/B8512G-E Accessories D8125 Zone Expansion Module D8128D OctoPOP1T Eight -pant Expander D8129 Octo-relay Module The 6600 ZONEX module includes two ZONEX busses (ZONEXI, ZONEX2). Compatible module ZONEX1 ZONEX2 D8125 Zone 1 1 Expansion Module D8128D OctoPOPIT 15 15 Eight -paint Expander D81290cto-relay 15 15 Module 1-19 Notice ZONEX, 0812x, and POPIT capacities are dependant upon the control panel's specified capacities. Quantity Component 1 ZONEX module 1 Hardware pack 1 Literature pack 1 ZONEX connection cable Properties Dimensions 2.76 in x 3.06 in x 1.03 in (70.3 mm x 9B mm x 26 mm) Weight 11.2 oz (0.30 kg) Environmental considerations Relative humidity 5%to 93% at +32°C (+90°F) Temperature (operating) 0°C to +49°C (+32°F to +120°F) Power requirements Current Standby 12 mA + total device current Alarm: 12 mA + total device current Voltage (input) 12VDC nominal Wiring Terminal wire size 12 AWG to 22 AWG (2.0 mm to 0.65 mm) SDI wiring Use the supplied interconnect cable (P/N:F01U079745) ZONEX wiring Use the supplied ZONEX connection cable (P/N:F01U295103) Ordering information B600 Retrofit (ZONEX) Module Retrofit (ZONEX) module providing legacy support for ZONEX products with B9512G/88512G control panels. Order number B600 3 1 B600 Retrofit (ZONEX) Module R.Pres.nl.d bye E"-. Wddl. Eut, Mirk. Basch S.aunty Systems B.V P.O. Boa 8=2 5600 A Eindhoven The Nehed.nds e. Phon• 3140 2577 284 .m.a. s.cuntysyltemsobosch com emea baschs.curlty com 0—mye Bosch SIU,vhnluystem. Gmbh Rc bert-Bosch-Ring 5 85630 Grasbrunn G.-any www boschsecur Ry com O Bosch Se my Syst.ms 2016 ( Data subject to change without notice I6673934603 1 an, VG, I8. Aug 2016 North Aff-iue A k.-P-M. 6o1,05—ty Syst.me Ir< Roberl Bosch (SEAT Pt. �W, Security Syslems 130 Per mon Parkway 11 Blshan Street 21 Purport Now Yark 144t0 V;A Slnppor•573943 phone •1 Itm M0096 Phone: •6565712808 F.: +1 585 2239180 F. •65 6571 2699 on Gnehelpous bosh.-, in .Pr s.cuntpyu.m.®bosch com wwwbesch—r ty us www.b.$4hfecunly .1 a �1' mom_ !. www.boschsecuritycom i BOSCH Invented for fife This module is used for wiring connections to remote signaling devices. You can connect up to twelve D192G modules to the same system on compatible control panels. Wiring is supervised for open, short, or grounded circuit faults. The module powers notification appliances from the control panel power supply or from an Underwriters Laboratories, Inc. (UL 1481) Listed auxiliary 12 VDC or 24 VDC regulated/power-limited power supply for fire protective signaling units and commercial/residential burglar units. This feature allows the system to support more signaling devices on longer wire runs. It also allows the use of 12 V or 24 V notification appliances requiring the appropriate power supply. Supervises 12 VDC or 24 VDC NACs The D192G powers the notification devices from either the control panel's power supply or from a UL Listed Auxiliary 12 VDC or 24 VDC regulated power -limited power supply for use with Fire Protective Signaling Units and Commercial and Residential Burglar Units. The choice of power supply allows the use of 12 V or 24 V notification devices. ► Supervises 12 VDC or 24 VDC notification appliance circuits (NACs) ► Supervised signal silencing switch ► Notification appliance circuit rated at 3.0 A ► Multiple module configurations ► Mounts in panel enclosure Supervised Signal Silencing Switch The D192G module has a toggle switch for silencing the notification devices while testing the alarm panel. When this toggle switch is in the Silence (Off) position, the module indicates a supervisory trouble condition to the control panel. Multiple Module Configurations Several modules can be connected to the same zone or point on the control panel. If individual annunciation of a notification appliance circuit is desired, D192G modules can be connected to separate zones or points on -board or through the D8128D OctoPOPIT Eight -point Expander Mounts in Panel Enclosure The D192G mounts inside the control panel enclosure using existing mounting holes or with a D137 or D13B Mounting Bracket. Refer to the control panel's installation guide for more information on mounting. 2 ) D192G Notification Appliance Circuit (NAC) Module -Resion Certification USA l L AMCX: Central Station Alarm Units (UL1611),UL1635), APAW: Police Sta- tion Alarm Units (UL365, UL464), APOU: Proprietary Alarm Units (UL1076), NBSX: Household Burglar Alarm System Units (IL1023), UOJZ: Control Units, System (UL664, 9th edi- tion) CSFM 7165-1615:0238 CSFM 7165-1615 0242 CSFM 7167-1615 0243 CSFM 7167-1615-0247 FDNY- 6059 CoA NYC- 12-92-E, Vol. 12 12.92-E, Vol. 12 MEA NYC- 12-92-E, Vol.15 12-92-E, Vol. 15 MEA Installation/configuration notes Compatibility Information Category Productl Control Panels G series' B-series2 D94123• D7412', D7212'' D9124' Detectors For a list of compatible two wire detectors, refer to the Approved Applications Compliance Guide for the control panel being used. Modules D8128D OctoPOPIT Eight point Expander Mounting D137 Mounting Bracket Brackets D136 Mounting Bracket, Right Angle ' G-series • D9412GV4, D7412GV4, 07212GV4•, D9412GV3, D7412GV3,D7212GV3',D9412GV2,D7412GV2,D7212GV2', D9412G',D7412G1,D7212G" 2 B series • B5512 and B4512 These products are legacy products and have been investigated for compatibility only to UL864 8th edition 'The D7212 models are not listed for commercial fire applications Notification Appliances Notification appliances used with the D192G Module must: • Be polarized (DC) equipment • Match the voltage rating of the alarm power supply • Not exceed the current rating of the alarm power supply • Not exceed 3.0 A in combined device current for each D192G Module Wiring Use a Class B, Style W, two -wire circuit and wire according to the instructions supplied with the module. No more than twelve D192G modules can be used per system. For UL applications, a listed (UTRZ) regulated power supply can be used to power notification devices through the D192G module. To comply with NFPA Standards: • The control panel and power supply must be supervised or installed in the same room not more than 20 ft (6 m) from the module • Wiring between the control panel and the power supply must be in conduit • Power supply fault conditions must be supervised by a UL Listed relay includedParts Quart. Component 1 NAC module 1 Hardware pack 1 Literature pack Technical specifications Electrical External Power In Current: 3.0 A maximum Voltage: 12 VDC or 24 VDC nominal Aux Power In Current: 1D0 rrA maximum Voltage: 12 VDC nominal Supervisory Zone Control Current: 5 mA maximum Mechanical Dimensions: 5 in x 3 in x 0 75 in (13 cm x 8 cm x 2 cm) e .. D192G Notification Appliance Circuit (NAC) Module The D192G Notification Appliance Circuit (NAC) module is used for wiring connections to remote signaling devices The wiring is supervised for open, short, or grounded circuit faults. Either 12 VDC or 24 VDC notification devices can be used depending on the choice of power supply. Order number D192G 3 1 D192G Notification Appliance Circuit (NAC) Module R.P-1.4 br Amark., Bosch Securiry Systems. Inc 130 P. Inton Parkway Furpon, New York, 14450, USA Phone:.1 goo 289 OD96 Faa:.1 585 2239180 sawrth aatn®us.bosch.com www.hoschs►curityus Eureye, Middle East. Alrkar Basch Security System. B.Y. P.O. Bo. 80002 5617 RA Eindhmen, The Netherland. Phone: • 3140 2577 294 Fair: U1 40 2577 330 .m.A. ucurlryayuems�basch. cam www. bosch s.Curl ty. com O Bosch Secunty Systems 20131 Data subject to change wghout notice 2537484427 1 .n, V4, 24. Oct 2013 Asl�P-MQ Robert Bosch (SEA) PIE Ltd. S.cumy System. 11 Blshan Street 21 Singapore 573943 Phan.:.65 6571 2808 Faa: •65 6571 2699 Apr. securitysystemsObos It"in www boschcecurlty. Aso Chi". Bosch IShanghall Security Systems Ltd. 201 Building, No. 333 Fuquan Road North ISP Changning D.strkt, Shanghai 700335 China Phone •86 21 22181111 Fair: -86 2122182396 www. beschsecunty corn cn Ath.rtca L.Unar RAb.R Bosch Ltd. Security Sptrms D,v,sion Via Anhanguara, Km 941 CEP 13065-900 GmpinAs, Sao Paula. Brazil Phone: -55 19 2103 2860 Fair: -55 19 2103 2062 let= boschsecurlty*boschcom www boschsecurlty ... 40 amm *am = I 9b:*e %a O,�� .SYSTEM � SENSOR" Sync•CircuitTM Module The Sync-Orcuit module synchronizes SpectrAlert® Advance strobes at I Hz and horns and chimes at temporal 3 over a single pair of wires. Patented module technology also allows the silencing of horns or chimes on horn/strobe and chime/strobe models over a pair of wires. Features • Two -wire operation from module to the devices • Silences horns and chimes over a two -wire loop • Synchronizes strobes at 1 Hz • Synchronizes horns and chimes to temporal 3 pattern • Patented technology • Interconnects modules for multiple zone synchronization • Module controls two Style Y (Class B) circuits or one Style Z (Class A) circuit • New NAC slave feature enables the interconnection of slave modules over a supervised NAC loop Agency Listings U` g X,, LISTEDo S4011 7300-1653:202 3032010 AIL I4,--ro m S s t e m S e n s o r The MDL3 Module is designed to work with the SpectrAlert and SpectrAlert Advance series of notification appliances to provide a means of synchronizing the temporal -coded horns and chimes, synchronizing the one -second flash timing of the strobe, and silencing the horns and chimes of the horn/strobe and chime/ strobes combination over a two -wire circuit while leaving the strobes active. Application Flexibility.The Sync -Circuit module is designed to power and synchronize either two 3-amp circuits wired in Class B, or one 3-amp circuit powered as Class A. Should more than two zones require synchronization, additional modules can be added by interconnecting the "slave" input and output terminals between modules. Sync•Circuit" Module Specifications Horns and Chimes Silenced Over Two -Wire Circuit Synchronization Circuit Module shall be a System Sensor Sync -Circuit Model 1. Any mix of Horn/Strobes, Chime/Strobes or Strobe -only devices is listed to UL 464 and UL 1971 and shall be approved for fire acceptable protective service.The module shall synchronize SpectrAlert® or SpectrAlert 2. Horn and chime control connects to interruptible power source Advance strobes at 1 Hz and horns at temporal 3. Also, the module shall be capable of silencing the horns on horn/strobe models, while operating the FACP strobes, over a single pair of wires. The module shall be capable of mounting r#1 + + HORN ZONE 11 * TO NEXT to a 411/16 x 411/16 x 21/s` back box and shall control two Style Y (class B) or NAC 1(B+ `` B- - EOL CONTROL OUT SPECTRALERT ADVANCE one Style Z (class A) circuit. The module shall be capable of multiple zone NAC B r6_ ± * ZONE1 ZONE2 }IN DEVICE OR EOL {�`g - OUT IcS BLEYZONES s nchronization b connectin multi le modules (slaves) to ether. Slaves y y g p g MASTER can be driven from either the slave output of a prior MDL3 or from the NAC NAC 3(+ + + �IIN 2 1 ± TONEXT output of the master. Using the NAC enables all wiring to be supervised, �`B6 SLAVNACE INl JJ! 1 ADVANCELERT DEVICE OR EOL whereas the slave -out terminals are not supervised, so their use is confined to S ouT{ ± }IN WIRING MUST BE 0 ® 1 CONTAINED WITH EITHER specific applications. h' I"I" TEMP JUMP OFF _ �� THE COMMON ENCLOSURE OF MODULES OR Note:The module shall not operate on a coded power supply. ENCLOSURES WITHIN20 FEET OF EACH OTHER WITH FACP #2 WIRING INSIDE CONDUIT Physical * HORN ZONE 11 ± Dimensions 51/4" L x 51/a"W _ }CONTROL OUTI l SPETO CTRALERT ADVANCE DEVICE Mounting 411/16` x 411/16 x 21/B" back box r NAC 1(B+ + B + )ZONE 1 ZONE 21 * N our Indoor Operating Temperature 320 to 120° F (00 to 49° C) SLAVE q+(+ ZONE2 NAC 1 ± )IN ±tCEAODVANICE T RALERT Electrical/Operating Specifications q_ _ SLAVEINI l DEVICE Operating Voltage 12 or 24VDC and FWR unfiltered SLAVE SLAVE ± STVLE ZZONES 1cvssn) _ IN O ® OUT Operating Voltage Range (12 V) 8.5 to 17.5 VDC TEMP JUMP OFF Operating Voltage Range (24 V) 16.5 to 33 VDC Maximum Load on Loop 3 Amps/zone U.S. Patent Nos. 5,598,139 5,850,178 Master -Slave Mode Master -Slave Using NAC-Slave Input FACP TT HORN ZONE TO NET FACP -PECTO VANCALERT VANCE CONTROL OUT - SPECTRALERT a VICE OR EOL A VANCE HORN ZONE r + ZONE1 ZONE 2J/ +IN EVICE OR EOL - CONTROL OUT NE T NAC 1+ (ASTER OUT1 ± cuss LE ZONES ECTRALERT 1 ZONE1 ZONE2VANCE j NAC2j+ + ZONE2 NAC1* TO NET SAPVACNRALERT NAC11 1 ± 1 _ IN OUTVICE C.'AVE(``IN SLf1VEVICE OR EOL SLAVEINII OR EOL r + * ZONE2 NAC L3 NAC + SLAVE SLAVE1 NAC 2(+ `` _ IN SLAVE IN _ SLAVE IN OR EOL _IN O ® OUTI ± 1 IRIN UST E CONTAINE ITH EITHER THE CO ON ENCLOSURE O* SLAVE SLAVEJO* 2°SSTs LE ZONES TE P U POFF ��OF O ULES OR O IN O® OUT O ENCLOSURES ITHIN2 FEET OF EACH OTHER ITH IRIN INSI ECON UIT FACP TE P U P OFF HORN ZONE 11 ± HORN ZONE1 }CONTROL OUTIRESPECTLE TO - CONTROL OUT _ ST LEZCLASSA 1 E r NAC3r+ + + 1ZONE1 ZONE21 NgC1 * ZONE1 ZONE2(``IN OUT SLAVE _ _ IN OUT7ONE ASTER TSPECTRALERT A VANCE EVICE OR EOL + + NAC( TONE NAC 2J + + +ZONE2 NACq _ 1ZONE2 INSLAVE IN 11E ll IN SLAVE IN SLAVEJI / STsEZZONES SLAV SLAVE E ± ± ±SLAVE fIN O ® OUT ± II OUT IN O ® TE P U POFF TE P U POFF Current Draw and Orderina Information MDL3R, MDL3W, 12 10 12 50 60 100 120 3.5 4 MDL3RA (Canadian) MDL3WA (Canadian) 24 12 15 60 75 120 150 4.5 5 SYSTEM ®2coanget hoots or. 3825 Ohio Avenue • St. Charles, IL 60174 Productspecficationssubjetttochangewtthoutnonce.Usttsystemsensoccomfor current inormatiooito ionofthisdaashetSENSOR® Phone:800-SENSOR2 • Fax:630-377-6495 A05-1•007-005.2/09•#2030 www.boschsecurity.com BOSCH Invented for life The cellular communicator enables secure two-way IP communication over the cellular network by plugging into a compatible control panel or communicator interface. • Alarm reporting to a central station • Remote control panel programming through Remote Programming Software with supported control panels • Remote monitoring and control through a mobile application with supported control panels • Personal notification using SMS for compatible control panels allotice COMar capability requires in InValler SerrirAs account and appropriate data plan. it. Secure Conettix IP communication from compatible Bosch panels to Bosch receivers using Verizon LTE cellular network ► Remote programming and monitoring of compatible Bosch panels ► E-mail notification options ► Direct configuration from Bosch Remote Programming Software (RPS) eliminates the need for separate set-up ► Simple LED status information and advanced keypad diagnostics available with easy two-step plug-in installation, troubleshooting, and maintenance e Q CD - ro 4 Callout - Description 1 Cellular communicator 2 Compatb a control panel,' communicator interface 3 Antenna cable 4 Magnetic base antenna 5 Base station on wireless carrier's network 6 IP network cloud Callout —Description 7 — Remote PC's network connection B Remote PC running RPS 9 — Personal SMS notification 10 — Ethernet connection 11— Central monitoring station 1 2 J B444-V Plug-in cell module, VZW LTE Functions Conettix IP communication via cellular In addition to the security provided by the network operator, the cellular communicator uses our Conettix IP protocol that supports: • Flexible polling intervals • Resistance to Denial of Service attacks • 128-bit to 256-bit AES encryption with Cypher Block Chaining • Anti- replay/anti-substi tut ion keys Easy installation, troubleshooting, and maintenance • No networking expertise required at field site (no firewall or router settings) • Signal strength and diagnostics available through keypad and Remote Programing Software (RPS) • Diagnostic LEDs for on -site troubleshooting SMA antenna connections Each module uses a two -port antenna connection and uses two SMA antennas to maximize cellular communications. LED Function Blue (heartbeat) System status indicator Red Unacceptable signal strength Yellow Marginal signal strength 1 Green Good signal strength 2 Green Very good signal strength Remote programming of Bosch control panels The cellular communicator supports secure RPS programming of compatible Bosch control panels. Remote Connect Programming Service support Remote Connect Programming Service enables a secure control panel connection to RPS using Bosch Cloud services. The service allows a secure TLS connection to a control panel without specific port and router settings and without a static IP or DNS. Personal notification and control The cellular communicator supports the Bosch Remote Security Control mobile application and can be configured for personal notification reports to mobile phones or e-mail addresses. fR'3� A.L llT [ 7 L11t7C1r L' C1 J J l:'3�C! Region CertHicatian USA Verizon Open Development Certified UL CP-01-2010 Control Panel Standard Features for False Alarm Reduction Region Regulatory compliance/quality marks USA UL UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems UL UL1076- Proprietary Burglar Alarm Units and Systems UL UL 1610 - Central Station Burglar Alarm Units UL UL 365 - Police Station Connected Bur- glar Alarm Units UL UL 609 - Standard for Local Burglar Alarm Units and Systems UL UL 636 - Holdup Alarm Units and Sys tems UL UL 985 Household Fire Warning Sys tem Units UL UL 1023 - Household Burglar Alarm Sys tem Units UL UL 1635 - Standard for Digital Alarm Communicator System Units FCC Part 15 Class B Canada ULC Underwriters Laboratories of Canada S1871-20121210 Mounting considerations The module plugs into any compatible control panel, available in a variety of enclosures. Wiring considerations The module connects to any compatible control panel without tools or physical wiring for power. When used with the B450, the B450 is wired to the control panel data bus. The cellular module has a screw on SMA antenna connection. Compatibilities Devices B9512G/B9512G-E,B8512G/B8512G•E B6512/B5512/B4512/B3512,B5512E/ 64512E/B3512E control panel with firmware v3.09 or higher (direct insertion) The module is compatible with most Bosch control panels when used with a B450 Conettix Piug-in Communicator Interface with firmware v3.09 of higher. Refer to the B450 datasheet for complete control panel competioduty usungs. B465 Conettix Universal Dual Path Communicator with firmware v2.09 or higher. B40-P, B40-MB25, B40-MB50 auxiliary indoor/ outdoor antennas clu�r 4GLTE- Cat 1with 3Gfallback B444-V Plug-in cell module, VZW LTE Commercial Fire and Burglary applications Ordering Approved for Commercial Fire/Burglary applications as sole, primary, or secondary communications path B444-V Plug-in cell module, VZW LTE when the system is installed to the NFPA-72 This communication module provides secure two-way specification IP communication on the Verizon Wireless network. Parts included Order number B444-V Accessories Quantity Component B40-MB25 Outdoor multiband antenna, cell, 25ft 1 Cellular module Provides wide bandwidth and low angle radiation _ pattern for indoor/outdoor applications. Supports 2 Antennas 2G/3G/4G data communication, Domestic (US) LTE 700 band, Global LTE 2600 band, Domestic (US) 1 Uterature pack Cellular, Global GSM, and WiMAX 2300/2500/2600 bands. Includes a 25 ft (7.6 m) cable, and a mounting Technical specifications bracket. Electrical Order number B40-MB25 Current Standby:35 mA (operating) Alarm.100 mA Voltage (operating) 12 VDC nominal Radio Verizon LTE CAT 1, Bands 2, 4, 5 and 13 Environmental Environment Environmental Class III - Indoor Relative humidity 5.93%at +32°C (+90eF) non -condensing Operating O'C to +49'C (+32eF to +1207) temperature Mechanical Board dimensions 2 in x 3.68 in x 0.60 in (50 mm x 93.5 mm x 15.25 mm) Antennas Magnetic base omni-directional (included) 3.3 ft (1.0 m) cable with SMA connector SIM card Verizon SIM R.prn t.d by: Europe. IAlddl. Ent. Alrlo. Bntch 5ecurlly systems B.v P.O. Bos B0002 5600 A Efndhoren, The Netherlands Phone: • 3140 2577 294 emuse<unt...snms®bosch com eme■ bo%Ch36CUrlty com C.ti1Mry Bosch Slcherheduysteme Gmbll Roberreasch Ring 5 85630 Grabrunn Germany www. boschsccuntycom L Bosch Setunry Systems 2020 ( data subject to change wrtnaut notice 695749912431en.v2.05 Feb 2020 B40-MB50 Outdoor multiband antenna, cell, 50ft Provides wide bandwidth and low angle radiation pattern for indoor/outdoor applications. Supports 2G/3G/4G data communication, Domestic (US) LTE 700 band, Global LTE 2600 band, Domestic (US) Cellular, Global GSM, and WiMAX 2300/2500/2600 bands. Includes a 50 ft (15.2 m) cable, and a mounting bracket. Order number B40-MBSO B40•P Outdoor puck antenna, cell, 6.5ft Omnidirectional, low profile antenna for metallic indoor/outdoor surface mounting. Supports LTE, and 2G/3G/4G data communication. Operates over 698-960 MHz and 1710.2170 MHz bands. Order number B40-P NMsh A~Icar Batch Secunty Systems. Inc 130 Pennon Parkway Falrpart New York 144S0 USA Phone -I NO 2690096 F.: • 1 5115 223 9180 onllnehetoaus boseh Corn www boschsecurltyus A.I.-P.01., Robert Basch (SLA) Pte Ltd. Sttunly Systt, s 11 &than Street 21 Singaoar. 573943 Phone: •65 6571 2608 Fast s65 6571 2699 aorsocuntysysl. obcxh com www basch--ly asia it L' I I t-i r J 1 ■ • ■ II F N