Loading...
BCOM2018-0041 Wall Framingke s fa September 13, 2019 Project: 46-630 Washington Street La Quinta, CA 92253 Kurt Fischer Structural Engineering Inc. KFSE18218 Subject: Back (East) Wall Validation with New Door Opening To whom it may concern: The back (east) wall of the structure located at the aforementioned address has been analyzed for structural adequacy, specifically with respect to the door opening at gridline C. The full length of this wall, at the time of permitting, was 116'8". The placement of the door on gridline C caused a loss of 6 feet of shear wall. This is a reduction of 5.1 % of the lateral capacity of the shear wall. Per section 403.4 of the California Existing Building Code (which is referenced by chapter 34 of the CBC), if the decrease in capacity of a lateral force resisting element is less than 10%, while the demand on the element remains the same, then the alteration to the element is acceptable, per the exception within that code section. Therefore, this modification to the north shear wall of this building is acceptable. Sincerely, Kurt Fischer Structural Engineering, Inc. Kurt Fischer, Lic. # S5432 • WWW.KFSENG.COM 17547 VENTURA BLVD, SUITE 302 • ENCINO, CALIFORNIA 91316 • T 818-874-1445 r. r 1t !!tE-mCw �WW_ S N EI Vs, i"WIR �.Mhl� F9:j) '1i,11A • -wknom .