Loading...
HomeMy WebLinkAboutBWFE2024-0324DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Wall / Fence BWFE2024-0324 57600 CORAL MOUNTAIN CT 762440035 Lot 3 MB 340/36 TR 29963 RL, 3 $18,000.00 Declaration / Acknowledgement BUILDING PERMIT athita CALIFORNIA PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 11/29/2024 ISSUED DATE: 12/04/2024 Owner: KEVIN MURRAY 57600 CORAL MOUNTAIN CT, LA QUINTA, CA 92253 Applicant: Drew Hudson 40905 Amador Drive, Indio, CA 92203 Contractor: Drew Hudson / 818121 40905 Amador Drive, Indio, CA 92203 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 12/4/24 10:03 am Page 1 of 4 BUILDING PERMIT Permit Type: Permit Number: Property Address: Wall / Fence BWFE2024-0324 57600 CORAL MOUNTAIN CT construction lender preliminary notice from that duty. Printed: 12/4/24 10:03 am Page 2of4 BUILDING PERMIT Permit Type: Permit Number: Property Address: Wall / Fence BWFE2024-0324 57600 CORAL MOUNTAIN CT Use of Permit MURRAY / 206 LF OF 6' HIGH MAX GARDEN WALLS WITH 2 PILASTERS AT STREET ENTRANCE [CITY STANDARD SPECIFICATIONS]. PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABL PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2022 CALIFORNIA BUILDING CODES. Construction Details Garden Wall Linear F000tage Total Block Wall LF 206 General Plan Lot Number Legal Description 206 LDR 3 Lot 3 MB 340/36 TR 29963 Engineering Other fence Linear Footage City Limits Lot Size City Standard 0 Combination Retaining 0 Wall Linear Footage Zoning RL Within La Quinta Limits Subdivision Name 12417 Centerlines TR 29963 17585 Valuation Details Type Group Sq Ft Value Financial Information Invoice No. INV-00011039 Fee Block Wall - Each Additional 50 LF Technology Enhancement Fee Block Wall - First 100 LF Digital Archiving and Records Management Fee - OTC Block Wall - First 100 LF PC Building Standards Administration Fee Amount Amount Paid $57.27 $57.27 $10.02 $10.02 $63.62 $63.62 $12.00 $12.00 $79.53 $79.53 $1.00 $1.00 Total for Invoice INV-00011039 $223.44 $223.44 Grand Total for Permit $223.44 $223.44 Workflow / Inspections Workflow Step / Action Name Plan Check v.1 Action Type Start Date End Date 12/02/2024 0:00 12/04/2024 8:21 Building Review (1 Day) v.1 Permit Issuance v.1 Receive Submittal 12/02/2024 0:00 12/04/2024 8:21 12/04/2024 8:21 12/04/2024 9:03 Contractor / Owner -Builder Information v.1 Generic Action 12/04/2024 8:21 Verify & Invoice Fees v.1 Generic Action 12/04/2024 8:21 Ready to Issue v.1 Generic Action 12/04/2024 8:21 Verify Fee Payment & Issue Permit v.1 Generic Action 12/04/2024 9:02 Print, Attach, and Email Building Permit v.1 Create Report Wall / Fence Inspections v.1 12/04/2024 9:02 12/04/2024 9:03 Footing v.1 Inspection Bond Beam v.1 Final Inspections v.1 Inspection F. Nall / Fence Inspection Printed: 12/4/24 10:03 am Page 3 of 4 BUILDING PERMIT Permit Type: Permit Number: Property Address: Wall / Fence BWFE2024-0324 57600 CORAL MOUNTAIN CT Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 12/4/24 10:03 am Page 4 of 4 „h„ heightfrom top of footing Required when Adjacent to Property Line #4 Horizontal rebar (use bond beam block) ei 6" or8" block #4 horizontal at 32" max. o.c. (use bond beam block) SEE TABLE "A" — FOR REBAR SIZE AND SPACING (locate rebar in center of cell) 12” Reverse IIII=III . 10" y direction of hook on every other rebar f 1 r_I 11 r_ =IIII-III W (FOOTING WIDTH) SEE TABLE "A" (Shown at 6' Height) Table "a" " ,, „W„ Vertical reinforcement 3' 17" #4 @ 48" O.C. 4' 20" #4 @ 48" O.C. 5' 23" #4 © 48" O.C. 6' 29" #4 © 24" O.C. SEE TABLE "B" FOR REBAR SIZE AND SPACING (locate rebar in center of cell) Finish grade continuous (1) - #4 rebar (2) - #4 rebar IIII= continuous IIII= • All footings adjacent to slopes to be at least 5' to daylight as shown below. BOTTOM OF FOOTING NOTES- 1 )this design does not allow grade differentials of more than 6" on opposing sides of the wall. This is not a retaining wall. 2)fence heights are regulated — consult zoning regulations before beginning construction. 3) no water course or natural drainage shall be obstructed. 4) grout only the cells containing rebar. This wall is not designed for all cells to be grouted. 5)all rebar to be astm spec. A615, grade 40 minimum. 6)all rebarlapsplicesto be 24" minimum. 7)all masonry unitstobeastmC-90gradeN. 8) rebar to be centered in masonry cells. *SEE PAGE 2 FOR ADDITIONAL INFORMATION* DISCLAIMER: Alternate designs may be possible when provided with an engineered analysis. Use of this standard design is at the user's risk and carries no implied or inferred guarantee against failure or defects. SRO 9+ 5'MIN. • EMI IIII=III FOO"le(TING WIDTH) SEE TABLE "B" „h„ heightfrom top of footing (Shown at 5' Height) Table "b" «h„ �,W„ Vertical reinforcement 3' 19" #4 @ 48" O.C. 4' 22" #4@48"O.C. 5' 29" #4 @ 48" O.C. 6' 34" #4@24"O.C. Checkwith the Building Department to verify if a building permit is required. When a permit is required, the following inspectionsare required: 1) FOOTING; Excavation trench clean with steel in place and supported 3" above and away from the surrounding earth/dirt. 2) REBAR/PRE-GROUT; Bond beam rebar and vertical rebar in place - inspection prior to placing grout. 3) FINAL; After grout is placed - prior to any decorative cap placement. Western Riverside County Code Uniformity Program a�a CALIFORNIA City of La Quinta Building Department Freestanding BlockWall (760) 777-7125 78-495 Calle Tampico, La Quinta, CA92260 FAX (760) 777-701 1 11/13/2014 I Design and Development PAGE 1 OF2 REBAR PLACEMENT ILLUSTRATION (TYPICAL) All rebar splices 24" min. overlap FOOTING OPTION A DESIGN PARAMETERS: ACTIVE SOIL PRESSURE (PSF) =30 PASSIVE SOIL BEARING (PSF) =150 COEFFICIENT OF FRICTION = 0.25 ALLOWABLE SOIL BEARING (PSF) =1500 WIND = 80 MPH, EXPOSURE C SEISMIC: Na=1.3, Nv=1.6, Z=0.4, SOIL PROFILE=Sd (TYPICAL) only cells and bond beam courses with rebar to be grouted (do not solid grout entire wall - use grout stop mesh as appropriate) ► (TYPICAL) All rebar shall have a minimum of3"concrete cover at footings Western Riverside County Code Uniformity Program 4aa CALIFORNIA City of La Quinta Building Department Freestanding BlockWall (760) 777-7125 FAX (760) 777-701 1 78-495 Calle Tampico, La Quinta, CA 92260 11/13/2014 I Design and Development PAGE2OF2 27" V/ f 6' MAX GRADE 27" TOP VIEW FOOTING BLOCK GROUT STEEL REBAR REBAR PLACEMENT ILLUSTRATION SECTION VIEW BLOCK (1 2" X 1 2" OR 16" X 16") SOLID GROUT (4) - # 4 REBAR (ONE AT EACH CORNER) MIN 24" REBAR OVERLAP A 20" 16" f 4" 27" ALL FOOTINGS ADJACENT TO SLOPES TO BE AT LEAST 5' TO DAYLIGHT AS SHOWN BELOW. BorrcM o5' MIN. ' FOOTING FOOTING REBAR SHALL_ I IAVEA MIN 6" LONG' HOOK ANO A MIN. CONCRITE COVER OF 3". CHECK WITH THE BUILDING DEPARTMENT TO VERIFY IF A BUILDING PERMIT IS REQUIRED. WHEN A BUILDING PERMIT IS REQUIRED, THE FOLLOWING INSPECTIONS ARE ALSO REQUIRED: 1) FOOTING: EXCAVATION TRENCH CLEAN WITH STEEL IN PLACE AND SUPPORTED 3" ABOVE AND AWAY FROM THE SURROUNDING THE EARTH/DIRT. 2) REBAR/PRE-GROUT; VERTICAL REBAR IN PLACE - INSPECTION PRIOR TO PLACING GROUT. 3) FINAL: AFTER GROUT IS PLACED - PRIOR TO ANY DECORATIVE CAP PLACEMENT. DISCLAIMER: ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH AN ENGINEERED ANALYSIS. USE OF THIS STANDARD DESIGN IS AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED GUARANTEE AGAINST FAILURE OR DEFECTS. MIN. 24" REBAR OVERLAP LIMITATIONS: 1. PILASTER SPACING SHALL NOT EXCEED 20 FT. WHEN OTHER INFILL FENCING IS ATTACHED. 2. ONLY OPEN TYPE FENCING (SUCH AS WROUGHT IRON) MAY BE ATTACHED TO PILASTERS. SOLID TYPE FENCING MAY NOT BE ATTACHED TO PILASTER. 3. GATES AND DOORS ATTACHED TO PILASTER ARE LIMITED TO 200# MAX. WEIGHT AND 4 FT. MAX. WIDTH PER PILASTER. 4.THIS PILASTER DESIGN IS INTENDED TO BE USED ONLY AS A FENCING FEATURE AND IS NOT INTENDED TO SUPPORT ANY OTHER LOADS . 5, FENCE HEIGHTS ARE REGULATED — CONSULT ZONING REGULATIONS BEFORE BEGINNING CONSTRUCTION. 6. INSTALLATION OF ELECTRIC CIRCUITS, CONDUITS, OR LIGHTING FIXTURES REQUIRE ELECTRICAL PERMITS AND INSPECTION, 7. FOOTINGS TO BE PLACED IN UNDISTURBED SOIL OR PROPERLY COMPACTED AND ENGINEERED FILL. 8. FOR DESIGN PARAMETERS. SEE FREESTANDING BLOCK WALL STANDARD. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM Tait ot eefdathitai MASONRY PILASTER PHONE (760) 777-7125 FAX (760) 777-7011 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 10/9/2014 'COMMUNITY DEVELOPMENT DEPT. PAGE 1 Of I M 0 CD 0' 0 0 -0Q=0 .-0 CD m 0 0 0 U 0 0La•3 0 0 c=• 0 .° 0 0 0 CD —• rt 0 G —• O - O + 0 O c O ° - 0_ Cn 7 O . co CL m U o c m o - - N O 0 0 CI) E n O - fl fi = 3 cn X<0� 0 0 0 0 = -000 =0 5' rt CD -0 O 0 _ - O 3 0 — O 0 o— Q CD -, rt O fi O �. ▪ N CD 5 CD - O (.0O 0 - ▪ co CD O O O D = O D 0 u) h rt (D 7 _ o A =c0 O O 0 o_ cp co-1 CD CD d C= = O 0 to ` _, (n 0 0 .-< 0 -• CD `< 5" E CD = Q 0 L0 -0 0 = 0 0_ cn (1)0 CD - 0 co o E O �< CO/) o_ f+ o 0 - o CD O = 0 �' 0 0 0 O = O O 0 0 fi • CD CL 0 cn - 0 uo}on4suo3 O 0 0 Q 0 0 O 0 Co C) O 0 0 O O 0 f-. 0 0 O 0 (0 CD CD 0 s�ld.l,�a \ol.Dnx.l,s\oD xo.4 C-1 sIIIHs 0 D m RR a E TRA P 'ELCIS C oVER C eATI PROP C L M C 0 05 0)o h _o C 5 C 0 CD 0 _ 0 O O O O O O 0 0) 0_ C) O rt V1 OI13-1N)\S r- z 206LF of city standard block wall - noted in red p p T T T T T T T T T T T T T T T T T T T T T T T T T T T T T 38LF of 18" planter retaining wall - noted in blue ONI0N33 NO8I 1HOf10 1M H „99 BW F E2024-0324 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COM PUANCE BY: Edward Ghera DATE: 1210312024 V1dV 1NV1d ]8Wf1N 1 HS SaVOIHNI NOI1V0l] SMVOIGNI ��81�f1N 1i HS SMVOIGNI N011O]S SaVOIHNI / 206 L F OF 6' HIGH MAX GA ITH 2 PILASTERS AT STRE CE [CITY STANDARD SPEC! ON CONCRETE BLOCK SHAL D WITH STUCCO, PAINT, OR WHERE VISIBLE FROM OU RB AND ANY FENCING SHALL BE IIVM ,9 DNILSIXS E F CO N33d0 ONlllfld 5'S=73 ▪ O O o 0 Q z CD CD Q o m Z :3 5"-I o 0 O 0 -0 D 0 o Q o m 0 T CI) mP1 c7 m 0 CD _0:5 1c)ioc7 I :3›.17j CD CD O O 0 RDEN :1 0 D z c) m T N QD O o !CATION L BE ri) TEXTURO) SIDE THE E BACK OF C) O Z CD m P1 D 0 5' 0 1HO11 CA CA DJ SNV1d S10311H0dV dad co C m 7D 00 D O rm cn • F- r T 23 0 D 71 rm D z 0 D 71 rm D Z 1HO11 133HM d0100 JId1N3d v 71 73 0 71 D S1IV130 dad :100d "H & " ON SHEET L-5, LIGHTS PER PLAN "I" ON SHEET L-5 CI n S0NIN3d0 11V0 d30Nf1 S110f1NI1N00 38 01 SONI100H 11VM CJ1 'XVW '0'0 „0—,5Z 1V S11VM NI S1N10C NOISNVdX3 301AOdd TIVM ,9 V 01 IAIKANO0 11VHS 1N1W1O ONV111:10d DNI,LSIXR SdV8 1VOI1d3A 01 ONIOVdS ONV HIS NI 1Vfl 1SV11 IV 38 11VHS S13M00 O m 71 r- CD D r- r- m O O Z 0 C/) CA N0110f1d1SNOO ONINIOf OV d08 M011V S1N1W3dON1 >10018 N1A3 NI S0N1100d d31S `3f1d1 GNV 81A1f11d S11VM 1Of1N1SNOO 'IIVM ,9 DNLLSIXa f m z 71 O O z O m m r- C/) D m 0 m m O m 0 D 7J W'1'S'V 01 ONIWd0dN00 D CY) 0 N `1N3130 1dVd 0110S 51130 11V 1f10d0 `ONINIVIId dl — 01105 13315 HUM S1130 11V 1f10dO S310N 11VM JldNOSVW AO 1d01S V a3303 01 ION S>1VM 1Odf Odd N O O G) 7) D 0 m z TIVM ,9 ONLLSIXa 7) D m C/) z O C 0 z O C/) Z O O 71 x m Fri 0 D r- O 71 O m N O 00 O 777 0 rr1 Z C/) C 777 n m O n O 773 D 71 m 777 D z O 71 O m 0 777 71 O Z m r- O O 777 O O Z O O 0 CO CD IIVM ,9 DNLLSIXa kNNkk```k t ```````k*` � ♦00u�44;`1m2: �♦ ,♦*0♦♦*♦♦♦♦♦AN♦♦♦A♦No ♦ ♦ ti♦� ♦ ♦ek♦♦`41/4 ♦ ♦♦e`�``Nit`iIvl`,```,tya`````j```k`!,` 44♦♦♦♦♦♦♦♦♦♦ll♦i♦��♦�♦�♦��♦�♦�♦;;♦♦�♦�♦�♦♦��• .♦e�♦����♦�♦�a��♦�•��o�♦�♦�����������♦'♦'���' �\'� ' .♦�`�k `AkkA``` ` sk• ks*```kk*A``` `````-' D D ZI 0 O 773 D 0 HI Z D D Z OCR/) m cn y 773 0 O 71 D z U) 773 O O Z m O O O O Fri 7) z z O O O 0 Fri Ca t IN```` ` ` ` `� � ♦```````y````�`�``````♦k1♦,1♦k♦1,*♦♦�o♦i`` C/) r- 71 m C/) r- 71 71 f1WINIW V IV SV3dV N3H1dV3 11V O m O 0 7J D Z N -D 777 71 m 71 777 71 0 30Vddf1S HSINIJ M0138 „!. l 30Vd0 HSINIH 010H 7J m O PT1 0 71 z O 71 O 71 7J O C Z 0 z O D Ca 0 D O 773 D m 0 O Z O D 0 z O r- z 71 O c/) O Z C/) m O 777 O c/) P1 0 77J D z D O rT1 O - Ti D ✓ — ✓ - r- D Z 0 cn CD D 7- 1 0 D 7) m D c/) O D 71 m CFI C/) r- O 0 m D ✓ - ✓ - 0 D z O m 0 —El IN ShcON ONI0V2:10 HSINIJ TIV ,9 3NLLSIXR O O z 0 C1111 C z 0 77 777 ✓ - ✓ - 0 D z O )=- CD )=- z O D z 0 O O O 0 r31 777 77 z AJ D C) O 43 D z O D z 0 C-) O z C-) 777 71 7- 1 U) C Lk.) O O z D (-) O AJ Ca D 777 71 O O O O 77 0 z D rT- l D z 0 6) LonLiSNOO ONINIOf GV d0J aO11V n C z r- 77 Cn U) O 71 77 CID 77 z 0 n D rTl 0 TIVM ,9 DNI,LSIXJ 'IIVM ,9 DNLLSIXa D z O 777 ClD 71 m D X -z D z z___ CJ7 O C zEf: C-) O r- O 777 71 0 O O 71 0 z z c) n O 0 71 C/) D z 0 D r- r- S D Fr- i 43 D ✓ - D z 0 O 0 z (1) A- J C O O z O O O z � 1 O 77 O D O r= C-) D w ✓ - 77 rTl n UJ D C/) r1l D F- ri 777 O 77 C/) D C AJ O z 11 •k„4 k►`1`1♦` z 0 O D P1 0 dSIML3H10 SS]1NN dfldl GNV 81/1f11d H8 01 O O O P1 77 Cf) 7- 7 71 z O O 0) IND CO 0 D SIIlON N011O11d1SNO0 s cc, i invE A euirneLE rErinn �r�Er�T� (OCTION PLAN � RoE o��N"�2022 MURRAY RESIDENCE � �J YS�HE TY , > , FU RI IABUILDING CODE � � DE 5 o � � So� CONSTRUCTION C" � 57600 CORAL MOU\TAIN COURT Landscape P.O. Design Services Box 5703 �1 PLA\ LA QUINTA, CALIFOR\ IA 92253 La Q°'°ta, California 92248 email: Gustavo@GMFutureDesigns.com TEL: 760-315-7473WWW GMFutureDesigns.comTEL:760-315-7473 THESE PLANS, DRAWINGS AND SPECIFICATIONS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER WITHOUT THE EXPRESSED WRITTEN CONSENT OF GM Future Designs