Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2025-0104
DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar BSOL2025-0104 57600 CORAL MOUNTAIN CT 762440035 Lot 3 MB 340/36 TR 29963 RL, 3 $45,000.00 Declaration / Acknowledgement BUILDING PERMIT athita CALIFORNIA Owner: KEVIN MURRAY PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 07/11/2025 ISSUED DATE: 08/05/2025 Applicant: CARMEN MESHACK 45350 SAN LUIS REY, PALM DESERT, CA 92260 Contractor: CARMEN MESHACK / 988895 45350 SAN LUIS REY, PALM DESERT, CA 92260 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 8/5/25 1:30 pm Page 1 of 3 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2025-0104 Property Address: 57600 CORAL MOUNTAIN CT Use of Permit 12.0 kW ROOF MOUNTED SOLAR PV SYSTEM - (30) 400W JAM72S03 MODULES, (30) TESLA MCI , (1) TESLA 7.6KW INVERTER WITH INTEGRATED DC DISCONNECT, 200A NC DISCONNECT, INTERCONNECTED WITH 200 AMP SOLAR BREAKER, 600 AMP MAIN BREAKER [640SF] 2022 CALIFORNIA ELECTRICAL CODE. Construction Details PV System Type PV Miscellaneous Equipment EA City Limits Lot Size Residential 2 System Size (kW DC) 12 PV Strings (EA) 3 Zoning RL General Plan LDR Within La Quinta Limits Subdivision Name TR 29963 Lot Number 3 12417 Centerlines 17585 Legal Description Lot 3 MB 340/36 TR 29963 Valuation Details Type Group Sq Ft Value Financial Information Invoice No. I N V-00016545 Fee Solar (PV) More than 10kW Solar (PV) More than 10kW PC Electrical Miscellaneous Apparatus,Conduits,&Co PC Digital Archiving and Records Management Fee - OTC Permit Issuance Technology Enhancement Fee Electrical Miscellaneous Apparatus,Conduits,&Condu Building Standards Administration Total for Invoice INV-00016545 Fee Amount $47.72 $47.72 $63.62 $12.00 $120.88 $17.18 $63.62 $2.00 Amount Paid $47.72 $47.72 $63.62 $12.00 $120.88 $17.18 $63.62 $2.00 $374.74 $374.74 Grand Total for Permit $374.74 $374.74 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 07/11/2025 13:08 Submittal Document Verification v.1 Generic Action 07/11/2025 13:09 Plan Check v.1 07/11/2025 0:00 07/30/2025 12:14 Solar - Outside Consultant Review v.1 Receive Submittal 07/11/2025 0:00 07/16/2025 14:21 Solar - Outside Consultant Review v.2 Receive Submittal 07/24/2025 0:00 07/30/2025 12:14 Permit Issuance v.1 07/30/2025 12:15 08/05/2025 13:30 Verify Contractor info & Conditions have been met v.1 Generic Action 07/30/2025 12:15 Verify & Invoice Fees v.1 Generic Action 08/05/2025 12:11 Verify Fee Payment & Issue Permit v.1 Generic Action 08/05/2025 13:29 Print, Attach, and Email Building Permit v.1 Solar Inspections v.1 Create Report 08/05/2025 13:30 08/05/2025 13:30 Rough Electrical v.1 Inspection Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 ' v.1 Inspection Printed: 8/5/25 1:30 pm Page 2 of 3 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2025-0104 Property Address: 57600 CORAL MOUNTAIN CT Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 8/5/25 1:30 pm Page 3 of 3 City of La Quinta July 16, 2025 BUREAU VERITAS Project Description: Solar Project Address: 57600 Coral Mountain Ct Application/ Permit #: BSOL2025-00104 Occupancy: R-3 Type of Construction: V-B Sprinklers: - Stories: - Floor Area (s.f.): - Fire Hazard Severity Zone/ WUI: - Flood Zone: - Fire Alarm: - Permit # BSOL2025-00104 BVNA# 27519761 Bureau Veritas has completed the first plan review of the below listed documents on behalf of the City of La Quinta Building & Safety Department: GENERAL INSTRUCTIONS 1. This plan review has been made to verify conformance to minimum requirements of codes and ordinances adopted by the City of La Quinta. Codes in effect for this project include the 2022 editions of the California Building Code (CBC), California Residential Code (CRC), California Green Building Code (CGBC), California Plumbing Code (CPC), California Mechanical Code (CMC), California Electrical Code (CEC), and California Energy Code (CEnC). The CBC is based on the 2021 editions of the International Building Code, which was published by the International Code Council. The CPC and CMC are based on the 2021 edition of the Uniform Plumbing and Mechanical Codes, respectively, which were published by IAPMO. The CEC is based on the 2020 edition of the National Electrical Code published by the National Fire Protection Association (NFPA). Applicable code sections are referenced after each item in this list. 2. These plans and documents have been reviewed for compliance with the applicable code requirements and instructions of the jurisdiction. The stamping of these plans shall not be held to permit or be an approval of a violation of any applicable codes and/or standards nor relieve the owner, design professional of record or contractor of compliance with any applicable codes and/or standards. Plan review of documents does not authorize construction to proceed in violation of any federal, state, nor local regulation. 3. The review does not necessarily include errors and omissions. Complete compliance is the responsibility of the designer. 4. All comments shall be resolved on the plans prior to the recommendation to the governing body for approval. 5. The comments identified in other sections of this review require clarifications/corrections before this plan check can be completed. 6. For reference for explanations in the examiner's comment sections, italic text refers to the initial submittals, bold text on second submittals, and underlined text on third submittals. 7. Please annotate your response in the areas on each comment, please see the comment section, 8. Submit a list showing any changes to the plan or previously submitted documents that are not the result of the plan check comments. Please "cloud" and/or "delta" all revisions made on plans due to this comment list as well as any other design changes. Page 1 of 2 City of La Quinta July 16, 2025 BUREAU VERITAS Permit # BSOL2025-00104 BVNA# 27519761 IN ORDER TO PROCESS THIS PLAN REVIEW PLEASE PROVIDE THE NAME AND PHONE NUMBER OF THE INDIVIDUAL WHO PREPARED THESE PLAN REVIEW RESPONSES NAME: PHONE: Please provide ONE full COMPLETE electronic submittal, with supporting documentation, and answers to ALL comments listed in the comment section and submit to: City of La Quinta, 78495 Calle Tampico, La Quinta, CA 92253 Respectfully Submitted, Arch/Access/Struc: Ernesto Pedroza, M.S.Iernesto.pedrozajr@bureauveritas.com1626.325.9800 Please write the sheet number, detail number, and/or location indicating where the comment is located. Please be specific as to where comment items have been addressed so that recheck may be expedited. To aid in the plan review process —please indicate in the space adjacent to each comment or on a separate sheet, the sheet and the exact location on the sheet where corrections have been made (e.g., Detail S of Sheet 3). Please "cloud" and/or "delta" all revisions made on plans due to this comment list as well as any other design changes. ELECTRICAL COMMENTS 1. Use a temperature correction factor for an ambient temperature of 114°F to 122°F. [§310.15 CEC] RESPONSE: END OF COMMENTS Page 2of2 ELLIIM 600 N Rosemead Blvd, Ste 233 220 Technology Drive, Ste 100 250 N Westlake Blvd, Ste 150 www.us.bureauveritas.com Pasadena, CA 91107 Irvine, CA 92618 Westlake Village, CA 91362 626.325.9800 714.431.4192 805.230.2888 Email: irvine.admin@bureauveritas.com LETTER OF TRANSMITTAL To: City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 sending you the following items: DATE July 16, 2025 SENT BY Megan Hsu COPIES PLAN CHECK NUMBER We are ADDRESS DESCRIPTION RESULTS 1 BSOL2025-0104 57600 Coral Mountain Ct Solar Roof -Mounted with Tesla CORRECTIONS 1 I Notes: _.� MI=F113"1117"sC —LA �ea:�: •� :��...... `:•. Harvest the Sunshine • 11. 400W PERC Half -Cell Module JAM72S03 380-400/PR CEO Introduction Assembled with high -efficiency PERC cells, the half -cell configuration of the modules offers the advantages of higher power output, better temperature -dependent performance, reduced shading effect on the energy generation, lower risk of hot spot, as well as enhanced tolerance for mechanical loading. Higher output power Less shading effect .Superior Warranty • 12-year product warranty • 25-year linear power output warranty Lower temperature coefficient Better mechanical loading tolerance 100% 80% 5 10 15 20 25 year JA Linear Power Warranty • Industry Warranty Comprehensive Certificates • IEC 61215, IEC 61730, IEC TS 62804 • ISO 9001: 2015 Quality management systems • ISO 14001: 2015 Environmental management systems • OHSAS 18001: 2007 Occupational health and safety management systems • IEC TS 62941: 2016 Terrestrial photovoltaic (PV) modules — Guidelines for increased confidence in PV module design qualification and type approval tsk PV CYCLE CLEAN et"'N EORTIL JA SOLAR www.jasolar.com Specificantions subject to technical changes and tests. JA Solar reserves the right of final interpretation. JA SOLAR JAM72S03 380-400/PR Inal MECHANICAL DIAGRAMS SPECIFICATIONS 40 imume Mai F MEIN MEIN h ill hill h ill M NMI lulu INN \Grounding holes Draining Iwlei- 6 places 8 places i. 1 1200 1 r -. 1600 2000 Junction box 400 300 \Mounting holes Label 8placs \❑ 941 Remark: customized frame color and cable length available upon request Units:mm AA Cell Mono Weight 22.5kg±3% Dimensions 2000mmx991 mmx40mm Cable Cross Section Size 4mm2 No. of cells 144 (6x24) Junction Box IP68, 3 diodes Connector MC4 Compatible(1000V) QC 4.10-35(1500V) Packaging Configuration 27 Per Pallet ELECTRICAL PARAMETERS AT STC TYPE JAM72S03 JAM72S03 JAM72S03 JAM72S03 JAM72S03 -380/PR-385/PR-390/PR-395/PR-400/PR Rated Maximum Power(Pmax) [W] 380 385 390 395 400 Open Circuit Voltage(Voc) [V] 48.05 48.32 48.61 48.91 49.17 Maximum Power Voltage(Vmp) [V] 39.80 40.07 40.34 40.63 40.92 Short Circuit Current(Isc) [A] 10.09 10.15 10.21 10.28 10.34 Maximum Power Current(Imp) [A] 9.55 9.61 9.67 9.73 9.78 Module Efficiency [%] 19.2 19.4 19.7 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_Isc) +0.051 %/°C Temperature Coefficient of Voc([i_Voc) -0.289%/°C Temperature Coefficient of Pmax(y_Pmp) -0.360%/°C STC Irradiance 1000W/m2, cell temperature 25°C, AM1.5G Remark: Electrical data in this catalog do not refer to a single module and they are not part of the offer.They only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT TYPE JAM72S03 JAM72S03 JAM72S03 JAM72S03 JAM72S03 380/PR-385/PR-390/PR -395/PR-400/PR Rated Max Power(Pmax) [W] 281 285 289 292 296 Open Circuit Voltage(Voc) [V] 44.51 44.80 45.04 45.30 45.56 Max Power Voltage(Vmp) [V] 36.81 37.05 37.29 37.52 37.76 Short Circuit Current(Isc) [A] 8.08 8.13 8.18 8.23 8.28 Max Power Current(Imp) [A] 7.64 7.69 7.74 7.79 7.84 NOCT Irradiance 800W/m2, ambient temperature 20°C, wind speed 1 m/s, AM1.5G OPERATING CONDITIONS Maximum System Voltage 1000V/1500V DC(IEC) Operating Temperature-40°C-+85°C Maximum Series Fuse 20A Maximum Static Load,Front 5400Pa Maximum Static Load,Back 2400Pa NOCT 45±2°C Application Class Class A CHARACTERISTICS Current -Voltage Curve JAM72S03-390/PR 10 9, 6 U 4 2 600W/m 400W/m' 200W/m' 00 10 20 30 40 50 Voltage(V) Power -Voltage Curve JAM72S03-390/PR 400 10 20 30 40 50 Voltage(V) Current -Voltage Curve JAM72S03-390/PR 10 8 - 40°C 55°C 6 - 70°C 0) U 4 - 10°C - 25°C 2 0 0 10 20 30 40 50 Voltage(V) Premium Cells, Premium Modules Version No. : Global_EN_20180927A SOLAR INVERTER 3.8 kW 1 7.6 kW Testa Solar Inverter completes the Testa home solar system, converting DC power from solar to AC power for home consumption. Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed, homeowners use the Testa mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique ecosystem experience. KEY FEATURES • Built on Powerwall 2 technology for • Designed to integrate with Testa Powerwall and Testa App exceptional efficiency and reliability • Wi-Fi, Ethernet, and cellular connectivity with easy over -the -air updates • 3.8 kW and 7.6 kW models available SOLAR INVERTER Testa Solar Inverter provides DC to AC conversion and integrates with the Testa ecosystem, including Solar Panels, Solar Roof, Powerwall, and vehicle charging, to provide a seamless sustainable energy experience. KEY FEATURES • Integrated rapid shutdown, arc • 2x the standard number of MPPTs for fault, and ground fault protection high production on complex roofs • No neutral wire simplifies installation ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS 1 OUTPUT (AC) 3.8 kW 7.6 kW Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V Maximum Continuous Current 16A 32A Breaker (Overcurrent Protection) 20 A 40 A Nominal Power Factor 1 - 0.85 (leading / lagging) THD (at Nominal Power) <5% INPUT (DC) MPPT 2 4 Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60 - 550 VDC DC MPPT Voltage Range' 60 - 480 VDC Maximum Current per MPPT (Inv) 11 A Maximum Short Circuit Current per MPPT (Ise) 15A Weight 52 I b4 Mounting options Wall mount (bracket) Door and bracket can be removed for a mounting weight of 37 lb. 660 mm 411 mm 00 00 00 O 0 00 O 0 O 0 00 O 0 O 0 O 0 O 0 00 @oo goo goo goo O 0 O 0 °foo O 0 O 0 -4— 158 —).- mm PERFORMANCE SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Peak Efficiency2 CEC Efficiency2 97.5% 98.0% Operating Temperatures -30°C to 45°C (-22°F to 113°F) 97.5% Allowable DC/AC Ratio 1.4 Customer Interface Testa Mobile App Internet Connectivity Wi-Fi (2.4 GHz, 802.11 b/g/n), Ethernet, Cellular (LTE/4G)3 AC Remote Metering Support Wi-Fi (2.4 GHz, 802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter (AFCI), Rapid Shutdown Supported Grid Types 60 Hz, 240 V Split Phase 60 Hz, 208 V Wye 'For the 7.6 kW Solar Inverter, performance may be de -rated to 6.2 kW at Required Number of Testa Solar See Solar Shutdown Device 240 V or 5.37 kW at 208 V when operating at temperatures greater than Shutdown Devices per Solar Module Requirements per Module on page 3 45°C. Operating Humidity (RH) Up to 100%, condensing Storage Temperature -30°C to 70°C (-22°F to 158°F) Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55 (Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m < 40 db(A) nominal, < 50 db(A) maximum Warranty 12.5 years 'Maximum current. 'Expected efficiency pending final CEC listing. 3Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION Grid Certifications UL 1741, UL 1741 SA, IEEE 1547, IEEE 1547.1 Safety Certifications UL 1699B, UL 1741, UL 1998 (US) T E 5 L n Emissions EN 61000-6-3 (Residential), FCC 47CFR15.109 (a) NA 2021-1-14 TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Testa Solar Shutdown Device is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with the Testa Solar Inverter, the PVRSS is initiated by any loss of AC power. ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS Nominal Input DC Current Rating (IMP) 12 A Maximum Input Short Circuit Current (I5C) 15 A Maximum System Voltage 600 V DC RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7W Warranty 25 years COMPLIANCE INFORMATION Certifications PVRSS UL 1741 PVRSS PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method Loss of AC power Compatible Equipment Testa Solar Inverter ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature -30°C to 70°C (-22°F to 158°F) Enclosure Rating NEMA 4 / IP65 Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw SOLAR SHUTDOWN DEVICE REQUIREMENTS PER MODULE t 250 mm 1 150 mm EL i H 125 mm M4 Screw M8 Bolt Nail / Wood Screw The following modules have been certified as part of a PV Rapid Shutdown Array (PVRSA) when installed together with the Testa Solar Inverter and Testa Solar Shutdown Devices. See the Testa Solar Inverter Installation Manual for guidance on installing Testa Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Testa Solar Roof V3 1 Solar Shutdown Device per 10 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules TESL n NA 2021-1-14 TESLA.COM/ENERGY Gateway 3 Testa Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self -consumption, time -based control, and backup operation. Performance Specifications Nominal Grid Voltage Environmental Specifications Compliance Information Mechanical Specifications Model Number Grid Configuration 1841000-x1-y 120/240 V AC Split phase AC Meter Communication User Interface +/- 0.5 /o CAN Testa App Grid Frequency 60 Hz Continuous Current Rating Maximum Supply Short Circuit Current 200 A 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker' IEC Protective Class Class I Overvoltage Category Category IV 'Only Eaton CSR or BWH main breakers are 25 kA rated Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Enclosure Type Certifications Emmissions Dimensions Backup Transition Overcurrent Protection Device Internal Panelboard Automatic disconnect for seamless backup 100-200 A Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or Square D HOM breakers rated to 10-125A Warranty 10 years —20°C to 50°C (-4°F to 122°F) Up to 100 /o, condensing 3000 m (9843 ft) 660 x 411x 149 mm (26x16x6in) Weight 16.3 kg (36 lb) Indoor and outdoor rated NEMA 3R UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2107.1, CSA 22.2 29 Mounting options Wall mount FCC Part 15, Class B, ICES 003 660 mm 4 411 mm Gateway 3 Datasheet 2024 ANCHOR CI PRODUCTS° Connections That Last The U2200 Base Plate is a lightweight mechanically attached solution for roofing manufacturer specified flashing. The U-Anchor is a versatile option for any rooftop project. U-ANCHOR® U2200 Base Plate Front U-Anchor Advantages • Extremely strong • Lightweight • Fast installation — installs in less than five minutes • Can be installed on any surface from flat to vertical on a parapet wall • Completely watertight when installed properly Back Product Description The U2200 Base Plate is a lightweight rooftop attachment consisting of a U-Anchor 2000 series plate. The U2200 Base Plate is made to be mechanically attached to the roofing system and flashed using a separate waterproofing approved by the roofing manufacturer. This is ideal for built-up roofs and pourable sealants. The U2200 Base Plate secures rooftop equipment quickly, safely, and effectively. Equipment Attachment • The U2200 Base Plate is attached by fastening through the roofing assembly into the structural decking with 2-8 approved fasteners. The U2200 Base Plate is then flashed using the manufacturer's recommended method. • To securely mount your rooftop equipment to the U-Anchor, after it is installed, the connection nut must be fastened to approximately 20-25 Ibf-ft. Use a calibrated torque wrench during the installation to ensure appropriate results are achieved. Excessive torque may damage the U-Anchor. • The U-Anchor bolt is stainless steel and applicable attachments provided by Anchor Products are tested as a system and designed to be compatible. • Refer to installation instructions and the specific roofing material manufacturer requirements before installing. MADE IN © Anchor Products 6316 Airport Fwy. Ste. D, Haltom City, TX 76117 Connections That Last U-2200 20240809 U. S. A. Cli Connections That Last ANCHOR PRODUCTS° Make the right choice for rooftop attachments with the U-Anchor. It's a one -of -a -kind attachment for commercial rooftop equipment securement. • Results: Plate performance only Ultimate Load - Shear: 4293 lbs. Ultimate Load - Tension: 2712 lbs. • Tested in accordance with FM 4481 Section 4.1 over 1/2" Steel. Assembly specific results may vary. Please contact Anchor Products® directly for additional testing results and information. • The shear value is obtained by testing at the base of the bolt. Account for the force of any attachment that increases the height of the connection point. Product Specs • Bolt 3/8"-16 x 1-3/8" Bolt* Material Type: 304 Stainless Steel • Plate Diameter: 5.5" Fastener Hole Diameter: 0.265" (8 holes) Fastener Hole Pattern: 4.125" Diameter Material Thickness: 0.047" Material Type: G90 Galvanized Steel • Patents Visit www.anchorp.com/resources/patents Packaging Specs • Sold Individually OR Full Box Quantity • Individual Weight: Approx. 0.4 lbs. • Full Box Quantity: 10 units • Box Weight: Approx. 6.6 lbs. • Box Dimensions: 17" x 17" x 5" • Full Pallet Quantity: 40 boxes • Pallet Dimensions: 40" x 48 x 51" U2200 Base Plate Dimensional Drawing [139.70] 5.500 3/8-16 X 1-3/8" 304 Stainless Steel Bolt .265 DRILL THROUGH 8 PLACES ON A 4.116 (104.5mm) BOLT CIRCLE PATTERN For Warranty Information Specified bolt option is standard. Custom options may be available for additional charge. Lead times may apply depending on roofing manufacturer and product availability. anchorp.com MADE IN © Anchor Products 6316 Airport Fwy. Ste. D, Haltom City, TX 76117 Connections That Last U-2200 20240809 U. S. A. SolarWedge® tilted racking system for flat (low -slope) roofs is available in 1°, 5°, 10°, or 15° tilt angles. It is Class A fire -rated for Type 1 and Type 2 modules with no height restrictions. Use with ProSolar's patented UL2703 self -bonding RoofTrac® rail and clamp technology for a simple, low cost, and reliable design. *rim • Low Cost. • Easy to Install. • Fully Engineered. • Class A Fire Rated. • ChemLink 3" E-Curb Compatible. Integrates with RoofTrac® Rail and Clamp Technology Available in 1 °, 5°, 10°, and 15° tilt angles Copyright © 2017 ProSolar° All rights reserved. All information contained in this brochure is property of Professional Solar Products (PSP). ProSolar°, RoofTrac°, and SolarWedge° are registered trademarks for PSP and are covered under US patents #6,360,491 and D547262. V. 3.72017 2-1/2" (Deep) Rail 72" Max Span 45 Ibs/ft2Test Load 125 mph Equivalent Wind Speed 1111 3" (Deep) Rail 96" Max Span 30 Ibs/ft2Test Load 110 mph Equivalent Wind Speed Side View Front Post Height: 5.25" (all tilt angles) Base Height _ 1.75" 48" Rear Post Height: 5.25" (1°); 8.25" (5°); 11.75" (101; 16.25" (15°) Parts List (6 Front and Rear Post Pairs Per Box) 1" Diameter Short Front Post (6) i 1" Diameter Tall Rear Post (6) 1-1/2" Diameter (1-3/4" Tall) Bases* (12) Rail Support (12) Rail Insert (12) 3" x 3" Aluminum Seal Plates (12) 3/8" SS Narrow OD Flat Washers (12) 0 3/8" SS Jam Nuts (36) 0 3/8" SS Flat Washers (24) 0 3/8" x 4" SS Leveling Studs (12) Rail Insert Rail Support 3/8" Jam Nuts/ Washers 3/8" Leveling Stud 3/8" Jam Nut Featuring: SolarWedge® Rail Lock For locking rails in place during marking and hole drilling process New! Lower -profile SolarWedge® Base *Base Compatible compatible with ChemLink E-Curb with 2" Tall, 3" Diameeterter For use with: Granulated Modified Bitumen, ChemLink E-Curb Asphalt and Coal Tar BUR, PVC, EPDM, PIB, and TPO Roofing See engineering for specification details. Check with AHJ for site -specific requirements. Specifications subject to change without notice. Intertek CERTIFICATE OF COMPLIANCE This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. Applicant: Address: Country: Contact: Phone: FAX: Email: Professional Solar Products, Inc. 1551 S. Rose Avenue Oxnard, CA 93033 USA Stan Ullman (805)-486-4700 (805)-486-4799 s@prosolar.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4007217 Authorized by: for Thomas J. Patterson, Director of Certification Manufacturer: Address: Country: Contact: Phone: FAX: Email: Professional Solar Products, Inc. 1551 S. Rose Avenue Oxnard, CA 93033 USA Stan Ullman (805)-486-4700 (805)-486-4799 s@prosolar.com 404- 14- ETL CLASSIFIED US uareo Intertek This Certificate of Compliance is for the exclusive use of lntertek's Client and is provided pursuant to the Certification Agreement between lntertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the Agreement. lntertek assumes no liability to any party, other than to the Client in accordance with the Agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit copying or distribution of this Certificate and then only in its entirety. Use of lntertek's Certification mark is restricted to the conditions laid out in the Agreement and in this Certificate. Any further use of the lntertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the Agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 2703 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels. Issued: 2015/01/28 Product: Photovoltaic Racking System Models: RoofTrac, FastJack, SolarWedge Certificate for Report Page 1 of 1 100779407LAX-003 Certificate Issued: 23-Mar-2015 ED 16.3.15 (1-Jan-13) Mandatory Intertek 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: Product Description: Ratings & Principle Characteristics: Models: Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Number(s): Professional Solar Products Inc. 1551 S. Rose Avenue Oxnard, CA 93033 Roof Mount Photovoltaic Mounting System. Fire Class Resistance Rating: -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roof's surface and a 1° inclination. Per Section 31.2.2.1 of UL 1703 this product can be installed with any gap stated in the manufacturers installation instructions. Per Section 31.2.1.6 of UL 1703 (rev. Oct 2015) the rating obtained for a 1° inclination can be used for any greater inclinations stated in the mounting instructions. ProSolar Solar Wedge ProSolar. UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition revision date Oct, 2015, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 04/26/2017 102966828MID-001 This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Title: Signature: Date: Christopher Zimbrich Reviewed by: Chad Naggs Technician I, Fire Resistance 04/27/2017 Title: Technical Team Lead, Fire Resistance Signature: Date: 04/27/2017 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014)