Loading...
BSOL2025-0104 Plans Revision 1SOUTHERN CALIFORNIA SMARTT ENERGY AJ Ortega 78495 Calle Tampico La Quinta, ca 92253 Narrative to Permit BSOL-2025-0104 Hello AJ, This is a narrative to the recently uploaded plans for the Murray Residence at 57600 Coral Mountain CT., La Quinta, CA 92253. 1. Design professional signed pages 1-5. 2. The Layout on the site placard now matches the the site plan. Please review Thanks, Brandon Slater SITE PLAN Scale: 1/50" = 1' AP\: 762-440-035 Ago pP arc _Property Line _ _ (N) 30 Solar Panels and 10 Tesla MCI 1 RSD Unit CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 09/17/2025 C --� Electric / Solar 11 Battery Equipment — See PV2 i 12.0 kW ROOF MOUNTED SOLAR PV SYSTEM — (30) 400W JAM72S03 MODULES, (30) TESLA MCI , (1) TESLA 7.6KW INVERTER WITH INTEGRATED DC DISCONNECT, 200A NC DISCONNECT, INTERCONNECTED WITH 200 AMP SOLAR BREAKER, 600 AMP MAIN BREAKER [640SF] 2022 CALIFORNIA ELECTRICAL CODE. Scope of Work Installation of a 12.0 kW Roof Mounted Solar PV System consisting of 30 JA Solar JAM72S03-400/PR (400W) Solar Panels & 30 Tesla MCI RSD Units, Strings of 10, 10 & 10 panels, landing In Tesla Powerwa113, 7600 watt Inverter113.5kWh Battery I N PV ANGLE I° MODULE WILL BE MOUNTED ON FLAT ROOF AZIMUTH NO 237° NTH NOTES - ALL WORK SHALL COMPLY WITH THE 2022 CA BUILDING CODE, 2022 CA RESIDENTIAL CODE, 2022 CA MECHANICAL CODE, 2022 CA ELECTRICAL CODE, 2022 CA GREEN CODE, 2022 CA PLUMBING CODE, 2022 CA ENERGY CODE, 2022 CA GREEN BUILDING STANDARDS CODE, 2022 CALIFORNIA AND RIVERSIDE COUNTY FIRE CODE. - MANUAL AC DISCONNECTS SHOULD REMAIN IN THE OFF POSITION AFTER FINAL BUILDING INSPECTION; SYSTEM IS NOT ALLOWED TO OPERATE UNTIL WRITTEN AUTHORIZATION IS PROVIDED IID - ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY - WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS - -REMOVAL OF A SCE -INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR - ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE - ALL FIELD -INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS - SOLAR BREAKER TO BE LOCATED ON OPPOSITE END OF MAIN BREAKER. - SOLAR ARRAY WILL NOT COVER ANY MECHANICAL OR PLUMBING VENTS. — The scope of this plan set is limited to design for permit and interconnection approval. It does not include installation services or on —site construction oversight. The installer is solely responsible for ensuring the system is installed in compliance with all applicable codes, manufacturer specifications, and jurisdictional requirements. — The contractor or installer is responsible for verifying all equipment placement, system configuration, racking attachments, and structural connections prior to and during installation. The designer is not liable for damage or code violations resulting from improper installation, unauthorized modifications, or site condition errors. — Structural design and attachment details are based on assumed conditions typical for the jurisdiction. It is the contractor's responsibility to verify all framing conditions in the field. If actual site conditions differ, a licensed structural engineer must be consulted before proceeding with the installation. — It is the responsibility of the installer to ensure final installation complies with the most current local building codes, fire codes, electrical codes (e.g., NEC), utility requirements, and manufacturer installation guidelines. — No warranty, expressed or implied, is provided by the designer regarding the performance, durability, or safety of the installed system. The contractor assumes full responsibility for system performance and safety post —installation. — All dimensions, measurements, and existing conditions shown in these plans must be verified in the field by the installer prior to installation. Any discrepancies must be reported and resolved before proceeding. The designer accepts no responsibility for errors arising from unverified or inaccurate site conditions. ATTACHMENT NOTES — Roof material is Single PLY — Installation is 2.83 Ibs/ft" 2 — Point load is maximum 33.3 Ibs/footing — Attachments spaced max. 72" OC — Modules on sloped roof will be mounted flush with roof (not to rise more than 6" above roof) — Lag Bolt is Stainless Steel 5/16" x 3-1/2" — Total Square Footage : 639.9 Contractor Lisc. Number Exp. Date Sheet Index PV1 — Site Plan & Cover Sheet PV2 — Roof Plan PV3 — Single Line Diagram and Calculations PV4 — Attachment Details PV5 — Signage Details 0 51. v- v C5 0 0 James Gillette — james:stlasdesignsunlimited.com T ME 0 1-0 CV CV 0) U C1 C3 J U 0 ME 0 0 CO Lo Date: 9-10-25 THE DRAWINGS AND SPECIFICATIONS AND DESIGNS REPRESENTED HEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE USED OR REPRODUCED FOR ANY PURPOSE OTHER THAN THE SPECFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOBSITE AND REPORT ANY DISCREPANCIES TO ARCHITECT. THE DRAWINGS AND SPECIFICATIONS INDICATE THE GENERAL SCOPE OF WORK AND REQUIRED TECHNICAL PERFORMANCE OF THE BUILDING SYSTEMS AND DO NOT NECESSARILY INDICATE OR DESCRIBE ALL THE WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE CONSTRUCTION CONTRACT. BASED ON THE SCOPE OF WORK INDICATED CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION OF THE PROJECT. ISSUE DATE PAGE TITLE: COVER SHEET PAGE NUMBER: Fire Dept. Access Point The photovoltaic inverter will be listed as UL 1741 compliant. (CEC 690.4D). Smoke alarms and Carbon Monoxide alarms are to be retrofitted into the existing dwelling. The required Smoke alarms and Carbon Monoxide detectors shall be located as required per sections R314 & R315 within the 2022 California Residential Code. (CRC R314, R315) All photovoltaic system conductors will be 90 degree C rated. (CEC 690.31B, , Table 310.15(B)(16), 310.15(B)(17). All exterior conduit, fittings, and boxes shall be rain —tight and approved for use in wet locations. (CEC 314.15). Any conductors exposed to sunlight shall be listed as sunlight —resistant. (CEC 300.6 C1, 310.10 D) All metallic raceways and equipment shall be bonded and electrically continuous.(CEC 250.90, 250.96) The photovoltaic arrays shall be provided with DC ground —fault protection. (CEC 690.5). Grounding bushings are required around pre —punched concentric knockouts on the DC side of the system. (CEC 250.97) Grounding electrode conductor will be continuous, except for splices or joints at bus bars within listed equipment. (CEC 250.64 C) 2"x 4" Rafters @ 24" O.C. Attachment @ 72" O.C. ARRAY AREA & ROOF AREA CALC'S ARRAY AREA (Sq Ft.) ROOF AREA (Sq Ft.) ROOF AREA (%) 639.9 9617.53 06.65 (N) Solar AC Disconnect Mechanical Room (E) 600A Panel and Main Net Meter (N) Inverter and Battery [EQUIPMENT INSIDE MECHANICAL ROOM)J BSOL2025-01 04 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 09/17/2025 BY---D C Note: All solar energy system appurtenances such as, but not limited to, electrical conduit, junction boxes water tanks, supports, and plumbing, shall be screened to the maximum extent possible without compromising the effectiveness of the solar collectors, and shall be painted a color similar to the color of the surface upon which it is mounted. DISCLAIMER: These plans are provided exclusively for permitting and interconnection approval. They are not to be used for construction purposes until all existing site conditions have been verified in the field by the licensed installer or contractor. The designer/engineer assumes no liability for errors, omissions, or damages resulting from discrepancies between actual site conditions and those shown in the plans. It is the sole responsibility of the contractor to confirm all measurements, structural details, and code compliance prior to commencing installation. ro ro 1- co 0 James Gillette — james itlasdesignsunlimited.com 0 Date: 9-10-25 ISSUE DATE PAGE TITLE: ROOF PLAN PAGE NUMBER: V-2 ELECTRICAL DIAGRAM (N) 30 JA Solar JAM72S03-400/PR (400W) Solar Panels & 10 Tesla MCI RSD Unit (1-Tesla MCI Per 3 Module) • • • f 111111111..I■ III II .IIIII 11111E1 1 1111111.. ■ III 111E 111 1 1111111/ 111111111.. ■ III 1I I.I I I 1 11111 II1 III..IN 1I. 1 ■I I1 11111' IIIIIIUUU III. 11.1 I 1 1111 11 1 111.. ■ 11 11.1 11 III IIIIIIIII..I. I I.III.1 11 11' 11111111111111111111111 1 IIIIIII..1. 11.1 .III 1 1 1111111..I■ III.111E11111 111111111..1 IN 111.111.11111 • 0 111111111..I■ III II ■I.II. 11/111111' 1111111110 I. 1 I.II .III 1 1111111 1111111110 II 1I■II .III 1 111111 1 1 1II■.1. 1 I■ I .III 1 1 111r 1 1 1110.IN 1I. I .III 1 1111.. 1 1 IIIN IN 1 I. I ■I111 1II 1 1 Iu■■1■ III■ 11.1111 11' 11111111111111111111 1 1 III..I. 111. 1 ■111 1 111111111..IN III.111E11111 111111111..In III 111E11111 (N)JBOX 1.! .!.. • 1111111111111111 1111111111111111 11111111 1111111 1111111111111111 1 1111 11 1111111 1111111111111111 '111111111111111111111111111111111 II 1 111111 111111 1111111111111111 III1111 11 111111 1111111111111111 11111 IIIIII 111 1111111 11111111111 III 111 111111 111111 1 11111 111111 A111111 11111 11 111111 1 11111 111111 111111111 1111 1111111111 11111111111111 CALCULATIONS (N)Tesla Powerwall 3,(N) 7600w Inverter integrated DC disconnect with an Integrated 13.5kW battery (N)200A240V Non -Fusible SOLAR A/C DISCONNECT 200A Testa Gateway 3 EPO Button POS DC NEG AC ©- © Testa Integrated 13.5 kWh Battery +/- 3/4" EMT conduit -(6) #10 AWG THHN/THWN-2 wire (1) #10 AWG THHN/THWN-2 ground 1. (6) #10 AWG USE-2 wire (1) #6 AWG Bare Copper ground PV MODULE RATINGS © STC INVERTER RATINGS MANUFACTURER JA SOLAR MANUFACTURER Tesla MODEL JAM72S03-400/PR MODEL 7.6kW MAX POWER -POINT CURRENT (Imp) 9.78 A CEC EFFICIENCY RATING 97.5% MAX POWER -POINT VOLTAGE (Vmp) 40.92 V MAX DC VOLT RATING 600 V OPEN -CIRCUIT VOLTAGE (Voc 49.17 V NOMINAL AC VOLTAGE 240 V SHORT CIRCUIT CURRENT (Isc) 10.34 A MAX. INPUT VOLTAGE 600 V MAX SERIES FUSE (OCPD) 20 A AC CURRENT 32 A MAXIMUM POWER (Pmax) 400 W OCPD RA11NG 40 A Inverter is UL Listed and Arc Fault Protected 0 i 0 (N) 200A Solar Breaker 0- 0 (E) 600A PANEL AND MAIN NET METER o °o (E) 200 Amp Critical _ 2 „ Loads Sub Panel 3/4' EMT conduit (3) #6 AWG THHN/THWN-2 wire (1) #8 AWG THHN/THWN-2 GEC BSOL2025-0104 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 09/17/2025 By' C 40A (Solar Breaker) + 600A (Main Breaker) = 640A < 720A (600A Buss Bar Rating x 1.2) EMT conduit (3) 3/0 AWG THHN/THWN-2 wire (1) #4 AWG THHN/THWN-2 GEC SYSTEM GROUNDING ELECTRODE (Ufer) CALCULATIONS MAX. INVERTER DC PHOTOVOLTAIC SYSTEM VOLTAGE EXPECTED AMBIENT TEMP. CORR. FACTOR # OF MODULES PER STRING x MODULE Vmp x LOWEST 10 x 40.92 x 1.14 = 466.48V PHOTOVOLTAIC SOURCE CIRCUIT CURRENT (MAX. SINGLE STRING CURRENT) MODULE Isc x 1.25: 10.34 x 1.25 = 12.92 A PHOTOVOLTAIC SOURCE CIRCUIT CURRENT (MAX. TOTAL STRING CURRENT) MODULE Isc x 1.25 x # OF STRINGS: 10.34 x 1.25 x 3 = 38.77 A MINIMUM INVERTER AC OVERCURRENT DEVICE RA11NG USE FACTOR: INVERTER OUTPUT CIRCUIT CURRENT x 1.25 CONT. 32 A x 1.25 = 40 A MIN. 40A Breaker * THE ASHRAE AREA EXTREME MIN TEMP (2 DEG C) IS USED. ** NEC 690.7 (A) MAXIMUM SYSTEM VOLTAGE: "WHEN OPEN -CIRCUIT VOLTAGE TEMPERATURE COEFFICIENTS ARE SUPPLIED IN THE INSTRUCTIONS FOR LISTED PV MODULES, THEY SHALL BE USED TO CALCULATE THE MAXIMUM PHOTOVOLTAIC SYSTEM AS REQUIRED BY 110.3 (B) INSTEAD OF USING TABLE 690.7" CONDUCTOR SCHEDULE & AMPACITY CALCULATIONS, CONDUCTOR SIZE DERATED FOR AMBIENT TEMPERATURE (SEE NOTE 1) SECTION CONDUCTOR TYPE CONT. CURRENT CONT. CURRENT x 1.25 TYP. WIRE SIZE (SEE NOTE 2) DERATED WIRE CAPACITY CALCULATIONS (SEE NOTE 2) DC WIRE USE-2 15 A 18.75 A 10 AWG 40 A x 0.82 x 0.8 = 26.24 A BARE COPPER EQUIP. GROUND 6 AWG SIZED AS PER CEC TABLE 250.122 AC WIRE THWN-2 32 A 40 A 8 AWG 55 A x 0.82 = 45.1 A INSULATED EGC 10 AWG SIZED AS PER CEC TABLE 250.122 / 250.66 Note 1: When available for location, the ashrae extreme annual mean temp and ashrae 2% design temp. are used for required low and high temperature calcutations. Note 2: Typical wire sizes provided include ambient temperature adjustment at 44°C, with a122° roof temperature adder where applicable. additional deratinq used 0.8 for 4-6 conductors in a raceway. Plans Drafted by. James Gillette - james S1 tlasdesignsunl im ited.com I° Solar breaker(s) is/are located at the opposite end of the buss bar from the main breaker. The sum of the breakers do NOT exceed the ampacity of the Buss bar. N 0) co co 0) 0) v CO James Gillette — james 1, 4 tlasdesignsunlimited.com Date: 9-10-25 ISSUE DATE PAGE TITLE: ELECTRICAL DIAGRAM PAGE NUMBER: PV -3 FOOTING DETAILS SEE FOR ENLARGED VIEW /- 12" MAX 2' 4' Rafters @ 24' ❑.C, — (E) SINGLE PLY ROOF / / (N) PROPOSED END CLAMP ASSEMBLY CN) PR❑S❑LAR 1-1/2' RAIL CN) CHEMLINK 1-PART POURABLE PENETRATI❑N SEALANT (N) U-ANCHOR PLATES / / / / / / / PV MODULES (E) FASTJACK E-SERIES 5,25' THREADED S❑LID ALUM POST (E) SINGLE PLY ROOF 2' 4' RAFTERS @ 24' ❑,C, 5/16' SS LAG SCREW WITH MIN 2-1/2' THREAD EMBEDMENT, IN PREDRILLED HOLES SEALED PENETRATI❑N, BSOL2025-0104 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 09/17/2025 BY---D C cn cal a) .N - •E N James Gillette — james5etlasdesignsunlimited.com N N 0) w Q (--) 1— >-- cn = U CY Q o J >_ CD - a--+ O = U o• 0_ _ o O o N o U O O UD Date: 9-10-25 ISSUE DATE PAGE TITLE: DETAIL PAGE NUMBER: DV• SIGNAGE DETAILS FORMAT: WHITE LETTERING ON A RED BACKGROUND. (2) MINIMUM 3/8 INCHES LETTER HEIGHT. (3) ALL LETTERS SHALL BE CAPITALIZED. (4) ARIAL OR SIMILAR FONT, NON -BOLD. MATERIAL: REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. To be installed on the Main Service Panel CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT 32 A NOM. OPERATING AC VOLTAGE 240 V WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE CAUTION: DUAL POWER SOURCES PRIMARY SOURCE IS UTILITY GRID SECONDARY SOURCE IS PV SYSTEM Photovoltaic Solar Panels PHOTOVOLTAIC SOLAR SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN SYSTEM TURN RAPID SHUTOFF SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY. RAPID SHUTDOWN SWITCH FOR SOLAR PHOTOVOLTAIC SYSTEM To be installed at DC Disconnect.. SOLAR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE DC DISCONNECT RATED MAX. POWER POINT CURRENT 29.34 A RATED MAX. POWER POINT VOLTAGE 491.7 V MAXIMUM SYSTEM VOLTAGE 600 V SHORT CIRCUIT CURRENT 31.02 A Conduits and Raceways Label every 10' WARNING: PHOTOVOLTAIC POWER SOURCE Facilities Placard — to be installed on face of Service Panel CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. AT: ME-1& MSP INVERTER AC DISCONNECT BATTERIES To be installed at AC Disconnect and any load centers. SOLAR AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 32 A NOM. OPERATING AC VOLTAGE 240 V To be installed at Inverter WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT. WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT To be installed at Battery and any load centers. BATTERY 1 OF 2 BATTERY 2 OF 2 ENERGY STORAGE SYSTEM DISCONNECT CAUTION TRI POWER SOURCES SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PV SYSTEM ESS (BATTERY) MAXIMUM DC VOLTAGE 92V NOM. OPERATING AC VOLTAGE 240V BSOL2025-0104 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 09/17/2025 BY� C All signage to be Permanent and Weather Resistant SIGNAGE COMPLIES WITH 2022 CEC 690.13(B), 690.31(B)(1), 690.31(G) co co co James Gillette james 1 itlasdesignsunlimited.com U 0 a 57600 Coral Mountain Date: 9-10-25 ISSUE DATE PAGE TITLE: SIGNAGE DETAIL PAGE NUMBER: PV- 5 Harvest the Sunshine ::;: _ — .�. �*:-- _• .� - ter; \ \\\ ••X\\�X\\\\:: \\\ \\\\\\\"\\%%\\\\:. 400W PERC Half -Cell Module JAM72S03 380-400/PR Ma Introduction Assembled with high -efficiency PERC cells, the half -cell configuration of the modules offers the advantages of higher power output, better temperature -dependent performance, reduced shading effect on the energy generation, lower risk of hot spot, as well as enhanced tolerance for mechanical loading. Higher output power Less shading effect .Superior Warranty • 12-year product warranty • 25-year linear power output warranty Lower temperature coefficient Better mechanical loading tolerance 100% 80% 10 15 20 25 year JA Linear Power Warranty • Industry Warranty Comprehensive Certificates • IEC 61215, IEC 61730, IEC TS 62804 • ISO 9001: 2015 Quality management systems • ISO 14001: 2015 Environmental management systems • OHSAS 18001: 2007 Occupational health and safety management systems • IEC TS 62941: 2016 Terrestrial photovoltaic (PV) modules — Guidelines for increased confidence in PV module design qualification and type approval t1 PV CYCLE v CLEAN et"-N EORTIL JA SOLAR www.jasolar.com Specificantions subject to technical changes and tests. JA Solar reserves the right of final interpretation. JA SOLAR JAM72S03 380-400/PR Inal TYPE Rated Max Power(Pmax) [W] Open Circuit Voltage(Voc) [V] Max Power Voltage(Vmp) [V] Short Circuit Current(Isc) [A] Max Power Current(Imp) [A] NOCT MECHANICAL DIAGRAMS SPECIFICATIONS 40 Grounding holes \6 places Draining Iwlea, 8 places N o N Jutian box 400 300 Mounting holes Label � 8 places l 941 Remark: customized frame color and cable length available upon request Units:mm Cell Mono Weight 22.5kg±3% Dimensions 2000mmx991 mmx40mm Cable Cross Section Size 4mm2 No. of cells 144 (6x24) Junction Box IP68, 3 diodes Connector MC4 Compatible(1000V) QC 4.10-35(1500V) Packaging Configuration 27 Per Pallet ELECTRICAL PARAMETERS AT STC TYPE JAM72S03 JAM72S03 JAM72S03 JAM72S03 JAM72S03 -380/PR-385/PR-390/PR-395/PR-400/PR Rated Maximum Power(Pmax) [W] 380 385 390 395 400 Open Circuit Voltage(Voc) [V] 48.05 48.32 48.61 48.91 49.17 Maximum Power Voltage(Vmp) [V] 39.80 40.07 40.34 40.63 40.92 Short Circuit Current(Isc) [A] 10.09 10.15 10.21 10.28 10.34 Maximum Power Current(Imp) [A] 9.55 9.61 9.67 9.73 9.78 Module Efficiency [%] 19.2 19.4 19.7 19.9 20.2 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_Isc) +0.051 %/°C Temperature Coefficient of Voc([i_Voc) -0.289%/°C Temperature Coefficient of Pmax(y_Pmp) -0.360%/°C STC Irradiance 1000W/m2, cell temperature 25°C, AM1.5G Remark: Electrical data in this catalog do not refer to a single module and they are not part of the offer.They only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT OPERATING CONDITIONS JAM72S03 JAM72S03 JAM72S03 JAM72S03 JAM72S03 -380/PR-385/PR-390/PR-395/PR-400/PR 281 285 289 292 296 44.51 44.80 45.04 45.30 45.56 36.81 37.05 37.29 37.52 37.76 8.08 8.13 8.18 8.23 8.28 7.64 7.69 7.74 7.79 7.84 Irradiance 800W/m2, ambient temperature 20°C, wind speed 1 m/s, AM1.5G Maximum System Voltage 1000V/1500V DC(IEC) Operating Temperature-40°C-+85°C Maximum Series Fuse 20A Maximum Static Load,Front 5400Pa Maximum Static Load,Back 2400Pa NOCT 45±2°C Application Class Class A CHARACTERISTICS Current -Voltage Curve JAM72S03-390/PR 10 9, 6 U 4 2 In 600W/m 400W/m' 200W/me 00 10 20 30 40 50 Voltage(V) Power -Voltage Curve JAM72S03-390/PR 400 10 20 30 40 50 Voltage(V) Current -Voltage Curve JAM72S03-390/PR 10 8 6 d U 4 2 - 10°C - 25°C - 40°C - 55°C 10 20 30 40 Voltage(V) 50 Premium Cells, Premium Modules Version No. : Global_EN_20180927A SOLAR INVERTER 3.8 kW 1 7.6 kW Testa Solar Inverter completes the Testa home solar system, converting DC power from solar to AC power for home consumption. Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed, homeowners use the Testa mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique ecosystem experience. KEY FEATURES • Built on Powerwall 2 technology for • Designed to integrate with Testa Powerwall and Testa App exceptional efficiency and reliability • Wi-Fi, Ethernet, and cellular connectivity with easy over -the -air updates • 3.8 kW and 7.6 kW models available SOLAR INVERTER Testa Solar Inverter provides DC to AC conversion and integrates with the Testa ecosystem, including Solar Panels, Solar Roof, Powerwall, and vehicle charging, to provide a seamless sustainable energy experience. KEY FEATURES • Integrated rapid shutdown, arc • 2x the standard number of MPPTs for fault, and ground fault protection high production on complex roofs • No neutral wire simplifies installation ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS OUTPUT (AC) 1 3.8 kW 7.6 kW Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V Maximum Continuous Current 16A 32A Breaker (Overcurrent Protection) 20 A 40 A Nominal Power Factor 1 - 0.85 (leading / lagging) THD (at Nominal Power) <5% INPUT (DC) MPPT 2 4 Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60 - 550 VDC DC MPPT Voltage Range' 60 - 480 VDC Maximum Current per MPPT (Inv) 11 A Maximum Short Circuit Current per MPPT (Ise) 15A Weight 52 Ib4 Mounting options Wall mount (bracket) Door and bracket can be removed for a mounting weight of 37 lb. 660 mm 411 mm O 0 00 O 0 00 00 O 0 O 0 00 00 O 0 O 0 00 LSO 00 00 O 0 O 0 O 0 O 0 °00 o0 O 0 -4— 158 mm PERFORMANCE SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Peak Efficiency2 CEC Efficiency2 97.5% 98.0% Operating Temperatures -30°C to 45°C (-22°F to 113°F) 97.5% Allowable DC/AC Ratio 1.4 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz, 802.11 b/g/n), Ethernet, Cellular (LTE/4G)3 AC Remote Metering Support Wi-Fi (2.4 GHz, 802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter (AFCI), Rapid Shutdown Supported Grid Types 60 Hz, 240 V Split Phase 60 Hz, 208 V Wye Required Number of Testa Solar See Solar Shutdown Device Shutdown Devices per Solar Module Requirements per Module on page 3 Warranty 12.5 years ' Maximum current. 2Expected efficiency pending final CEC listing. 3Cellular connectivity subject to network operator service coverage and signal strength. Operating Humidity (RH) Up to 100%, condensing Storage Temperature -30°C to 70°C (-22°F to 158°F) Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55 (Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m < 40 db(A) nominal, < 50 db(A) maximum 'For the 7.6 kW Solar Inverter, performance may be de -rated to 6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 45 ° C. COMPLIANCE INFORMATION Grid Certifications Safety Certifications UL 1741, UL 1741 SA, IEEE 1547, IEEE 1547.1 UL 1699B, UL 1741, UL 1998 (US) T E 5 L Fi Emissions EN 61000-6-3 (Residential), FCC 47CFR15.109 (a) NA 2021-1-14 TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Testa Solar Shutdown Device is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with the Testa Solar Inverter, the PVRSS is initiated by any loss of AC power. ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS Nominal Input DC Current Rating (IMP) 12 A Electrical Connections MC4 Connector Maximum Input Short Circuit Current (I5C) 15 A Maximum System Voltage 600 V DC RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7W Warranty 25 years COMPLIANCE INFORMATION Certifications PVRSS UL 1741 PVRSS PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method Loss of AC power Compatible Equipment Testa Solar Inverter ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature -30°C to 70°C (-22°F to 158°F) Enclosure Rating NEMA 4 / IP65 Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw 650 mm SOLAR SHUTDOWN DEVICE REQUIREMENTS PER MODULE t 250 mm 1 150 mm EL i H 125 mm M4 Screw M8 Bolt Nail / Wood Screw The following modules have been certified as part of a PV Rapid Shutdown Array (PVRSA) when installed together with the Testa Solar Inverter and Testa Solar Shutdown Devices. See the Testa Solar Inverter Installation Manual for guidance on installing Testa Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Testa Solar Roof V3 1 Solar Shutdown Device per 10 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules T E 5 L n NA 2021-1-14 TESLA.COM/ENERGY Gateway 3 Testa Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self -consumption, time -based control, and backup operation. Performance Specifications Nominal Grid Voltage Environmental Specifications Compliance Information Mechanical Specifications Model Number Grid Configuration 1841000-x1-y 120/240 V AC Split phase AC Meter Communication User Interface +/- 0.5 /o CAN Testa App Grid Frequency 60 Hz Continuous Current Rating Maximum Supply Short Circuit Current 200 A 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker' IEC Protective Class Class I Overvoltage Category Category IV 'Only Eaton CSR or BWH main breakers are 25 kA rated Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Enclosure Type Certifications Emmissions Dimensions Backup Transition Overcurrent Protection Device Internal Panelboard Automatic disconnect for seamless backup 100-200 A Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or Square D HOM breakers rated to 10-125A Warranty 10 years —20°C to 50°C (-4°F to 122°F) Up to 100 /o, condensing 3000 m (9843 ft) 660 x 411x 149 mm (26x16x6in) Weight 16.3 kg (36 lb) Indoor and outdoor rated NEMA 3R UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2107.1, CSA 22.2 29 Mounting options Wall mount FCC Part 15, Class B, ICES 003 660 mm 4 411 mm Gateway 3 Datasheet 2024 ANCHOR CI PRODUCTS° Connections That Last The U2200 Base Plate is a lightweight mechanically attached solution for roofing manufacturer specified flashing. The U-Anchor is a versatile option for any rooftop project. U-ANCHOR® U2200 Base Plate Front U-Anchor Advantages • Extremely strong • Lightweight • Fast installation — installs in less than five minutes • Can be installed on any surface from flat to vertical on a parapet wall • Completely watertight when installed properly Back Product Description The U2200 Base Plate is a lightweight rooftop attachment consisting of a U-Anchor 2000 series plate. The U2200 Base Plate is made to be mechanically attached to the roofing system and flashed using a separate waterproofing approved by the roofing manufacturer. This is ideal for built-up roofs and pourable sealants. The U2200 Base Plate secures rooftop equipment quickly, safely, and effectively. Equipment Attachment • The U2200 Base Plate is attached by fastening through the roofing assembly into the structural decking with 2-8 approved fasteners. The U2200 Base Plate is then flashed using the manufacturer's recommended method. • To securely mount your rooftop equipment to the U-Anchor, after it is installed, the connection nut must be fastened to approximately 20-25 Ibf-ft. Use a calibrated torque wrench during the installation to ensure appropriate results are achieved. Excessive torque may damage the U-Anchor. • The U-Anchor bolt is stainless steel and applicable attachments provided by Anchor Products are tested as a system and designed to be compatible. • Refer to installation instructions and the specific roofing material manufacturer requirements before installing. MADE IN © Anchor Products 6316 Airport Fwy. Ste. D, Haltom City, TX 76117 Connections That Last U-2200 20240809 U. S. A. CI Connections That Last ANCHOR PRODUCTS° Make the right choice for rooftop attachments with the U-Anchor. It's a one -of -a -kind attachment for commercial rooftop equipment securement. • Results: Plate performance only Ultimate Load - Shear: 4293 lbs. Ultimate Load - Tension: 2712 lbs. • Tested in accordance with FM 4481 Section 4.1 over 1/2" Steel. Assembly specific results may vary. Please contact Anchor Products® directly for additional testing results and information. • The shear value is obtained by testing at the base of the bolt. Account for the force of any attachment that increases the height of the connection point. Product Specs • Bolt 3/8"-16 x 1-3/8" Bolt* Material Type: 304 Stainless Steel • Plate Diameter: 5.5" Fastener Hole Diameter: 0.265" (8 holes) Fastener Hole Pattern: 4.125" Diameter Material Thickness: 0.047" Material Type: G90 Galvanized Steel • Patents Visit www.anchorp.com/resources/patents Packaging Specs • Sold Individually OR Full Box Quantity • Individual Weight: Approx. 0.4 lbs. • Full Box Quantity: 10 units • Box Weight: Approx. 6.6 lbs. • Box Dimensions: 17" x 17" x 5" • Full Pallet Quantity: 40 boxes • Pallet Dimensions: 40" x 48 x 51" U2200 Base Plate Dimensional Drawing [139.70] 5.500 3/8-16 X 1-3/8" 304 Stainless Steel Bolt .265 DRILL THROUGH 8 PLACES ON A 4.116 (104.5mm) BOLT CIRCLE PATTERN For Warranty Information Specified bolt option is standard. Custom options may be available for additional charge. Lead times may apply depending on roofing manufacturer and product availability. anchorp.com MADE IN © Anchor Products 6316 Airport Fwy. Ste. D, Haltom City, TX 76117 Connections That Last U-2200 20240809 U. S. A. SolarWedge® tilted racking system for flat (low -slope) roofs is available in 1°, 5°, 10°, or 15° tilt angles. It is Class A fire -rated for Type 1 and Type 2 modules with no height restrictions. Use with ProSolar's patented UL2703 self -bonding RoofTrac® rail and clamp technology for a simple, low cost, and reliable design. • Low Cost. • Easy to Install. • Fully Engineered. • Class A Fire Rated. • ChemLink 3" E-Curb Compatible. Integrates with RoofTrac® Rail and Clamp Technology •ti_ x.. `� _.�Mi'iill•vfy�c.�Q,• 140Z , Available in 1 °, 5°, 10°, and 15° tilt angles Copyright © 2017 ProSolar° All rights reserved. All information contained in this brochure is property of Professional Solar Products (PSP). ProSolar°, RoofTrac°, and SolarWedge° are registered trademarks for PSP and are covered under US patents #6,360,491 and D547262. V. 3.72017 2-1/2" (Deep) Rail 72" Max Span 45 Ibs/ft2Test Load 125 mph Equivalent Wind Speed 3" (Deep) Rail 96" Max Span 30 Ibs/ft2Test Load 110 mph Equivalent Wind Speed Side View Front Post Height: 5.25" (all tilt angles) Base Height 1.75" 48" Rear Post Height: 5.25" (1°); 8.25" (5°); 11.75" (101; 16.25" (15°) Parts List (6 Front and Rear Post Pairs Per Box) 1" Diameter Short Front Post (6) 1" Diameter Tall Rear Post (6) 1-1/2" Diameter (1-3/4" Tall) Bases* (12) Rail Support (12) Rail Insert (12) 1111 3" x 3" Aluminum Seal Plates (12) 3/8" SS Narrow OD Flat Washers (12) 0 3/8" SS Jam Nuts (36) 3/8" SS Flat Washers (24) 0 3/8" x 4" SS Leveling Studs (12) Rail Insert Rail Support 3/8" Jam Nuts/ Washers 3/8" Leveling Stud 3/8" Jam Nut Featuring: SolarWedge® Rail Lock For locking rails in place during marking and hole drilling process New! Lower -profile SolarWedge® Base *Base Compatible compatible with ChemLink E-Curb with 2" Tall, 3" Diameeterter For use with: Granulated Modified Bitumen, ChemLink E-Curb Asphalt and Coal Tar BUR, PVC, EPDM, PIB, and TPO Roofing See engineering for specification details. Check with AHJ for site -specific requirements. Specifications subject to change without notice. CERTIFICATE OF COMPLIANCE This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. Applicant: Address: Country: Contact: Phone: FAX: Email: Professional Solar Products, Inc. 1551 S. Rose Avenue Oxnard, CA 93033 USA Stan Ullman (805)-486-4700 (805)-486-4799 s@prosolar.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4007217 Authorized by: for Thomas J. Patterson, Director of Certification Manufacturer: Address: Country: Contact: Phone: FAX: Email: Professional Solar Products, Inc. 1551 S. Rose Avenue Oxnard, CA 93033 USA Stan Ullman (805)-486-4700 (805)-486-4799 s@prosolar.com Ell_ CLASSIFIED US uerEo Intertek 4,44- This Certificate of Compliance is for the exclusive use of lntertek's Client and is provided pursuant to the Certification Agreement between lntertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the Agreement. lntertek assumes no liability to any party, other than to the Client in accordance with the Agreement, for any loss, expense or damage occasioned by the use of this Certificate. Only the Client is authorized to permit copying or distribution of this Certificate and then only in its entirety. Use of lntertek's Certification mark is restricted to the conditions laid out in the Agreement and in this Certificate. Any further use of the lntertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the Agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 2703 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels. Issued: 2015/01/28 Product: Photovoltaic Racking System Models: RoofTrac, FastJack, SolarWedge Certificate for Report Page 1 of 1 100779407LAX-003 Certificate Issued: 23-Mar-2015 ED 16.3.15 (1-Jan-13) Mandatory Intertek 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: Product Description: Ratings & Principle Characteristics: Models: Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Number(s): Professional Solar Products Inc. 1551 S. Rose Avenue Oxnard, CA 93033 Roof Mount Photovoltaic Mounting System. Fire Class Resistance Rating: -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roof's surface and a 1° inclination. Per Section 31.2.2.1 of UL 1703 this product can be installed with any gap stated in the manufacturers installation instructions. Per Section 31.2.1.6 of UL 1703 (rev. Oct 2015) the rating obtained for a 1° inclination can be used for any greater inclinations stated in the mounting instructions. ProSolar Solar Wedge ProSolar. UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition revision date Oct, 2015, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 04/26/2017 102966828MID-001 This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Title: Signature: Date: Christopher Zimbrich Reviewed by: Chad Naggs Technician I, Fire Resistance 04/27/2017 Title: Technical Team Lead, Fire Resistance Signature: Date: 04/27/2017 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014)