HomeMy WebLinkAboutBRES2025-0285BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 06/25/2025
ISSUED DATE: 06/26/2025
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Building Residential
54087 SOUTHERN HILLS
BRES2025-0285
775101061
Lot 6 MB 199/51 TR 22432-3 SEE
ASSESSORS MAP BK 769/45 FOR CMS
$7,055.00
RL, 6
Owner:Cameron Buck
Applicant:Timothy Ellenz
Contractor:Bernard Adri
75100 Saint Charles Place, Palm Desert, CA
92211
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 4/9/26 9:21 am Page 1 of 4
Permit Type:
Permit Number:
Property Address:
Building Residential
BRES2025-0285
54087 SOUTHERN HILLS
BUILDING PERMIT
RETROFIT REPLACEMENT OF (4) WINDOWS. THIS PERMIT DOES NOT INCLUDE ALTERATION OF THE OPENINGS. 2022 CALIFORNIA
BUILDING CODES.
Use of Permit
Construction Details
RemodelResidential Work Type 0Conditioned Square
Footage
0Garage Square
Footage
0Patio Square Footage 0Fire Sprinkler Square
Footage
V-BConstruction Type
2022Code Edition 1Number of Floors 1Number of Units
R-3: 1 & 2 Family
Dwellings
Building/Unit
Occupancy
Classification(s)
NoGrading Required?0Dwelling Units per
Acre (CVMSHCP)
7055.00Original Valuation 0Remodel Area Square
Footage
0Addition Area Square
Footage
0Number of Patio
Cover(s)
0Number of Carport(s)0Number of Balcony
Addition(s)
0Number of Awning
Canopy(s)
0Reroof Area Square
Footage
0Stucco Application
Square Footage
4Number of
Door/Window
Retrofit/Repair
0Number of
Door/Window
New/Alteration
0Number of
Fireplace(s)
0Number of Partition(s)0Number of Flag or
Light Pole(s)?
0New Electrical Square
Footage
0Number of
Receptacle/Switch/Lig
ht(s)
0Number of Residential
Appliances
0Number of
Non-Residential
Appliances
0Number of Power
Apparatus
0Number of Signs NoElectrical Service?
NoTemporary Power
Service?
0Miscellaneous
Electrical
0Number of Forced Air
Furnace(s)
0Number of Wall/Floor
Heater(s)
0Number of Appliance
Alterations
0Number of
Condenser(s)
0Number of Air
Handling Unit(s)
0Number of Evaporative
Cooler(s)
0Number of Ventilation
Fan(s)
0Number of Exhaust
Hood(s)
0Miscellaneous
Mechanical
0Number of Plumbing
Fixtures/Traps
0Number of Roof Drains 0Number of Water
Heater(s)
NoWater System Install
or Alteration?
NoBack Flow Prevention
Device?
0Number of Gas
Outlet(s)
NoSewer Connection?
NoSeptic System?RLZoning LDRGeneral Plan
Within La Quinta LimitsCity Limits TR 22432-3 SEE
ASSESSORS MAP BK
769/45 FOR CMS
Subdivision Name 6Lot Number
17935, 17918, 17126,
17917, 99634, 93257
Centerlines 46648.6Lot Size Lot 6 MB 199/51 TR
22432-3 SEE ASSESSORS
MAP BK 769/45 FOR CMS
Legal Description
Valuation Details
Type Group Sq Ft Value
Printed: 4/9/26 9:21 am Page 2 of 4
Permit Type:
Permit Number:
Property Address:
Building Residential
BRES2025-0285
54087 SOUTHERN HILLS
BUILDING PERMIT
Financial Information
Fee AmountFee Amount PaidInvoice No.
INV-00015674 $0.92 SMI - Residential $0.92
$7.92 Technology Enhancement Fee $7.92
$1.00 Building Standards Administration $1.00
$24.00 Digital Archiving and Records Management Fee $24.00
$78.26 Door/Window, Retro/Repair PC $78.26
$80.16 Door/Window, Retro/Repair $80.16
$192.26 $192.26 Total for Invoice INV-00015674
Grand Total for Permit $192.26 $192.26
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Application Completeness Check v.1 06/25/2025 12:47
Submittal Document Verification v.1 Generic Action 06/25/2025 12:48
Plan Check v.1 06/25/2025 0:00 06/25/2025 16:38
Building Review (1 Day) v.1 Receive Submittal 06/25/2025 0:00 06/25/2025 16:38
Permit Issuance v.1 06/25/2025 16:58 06/26/2025 8:21
Contractor / Owner-Builder Information v.1 Generic Action 06/25/2025 16:58
Verify & Invoice Fees v.1 Generic Action 06/25/2025 16:58
Ready to Issue v.1 Generic Action 06/26/2025 8:20
Verify Fee Payment & Issue Permit v.1 Generic Action 06/26/2025 8:20
Print, Attach, and Email Building Permit v.1 Create Report 06/26/2025 8:20 06/26/2025 8:21
Inspections - Do Not Pour Concrete Until Approved v.1
Setbacks v.1 Inspection
Underground Plumbing v.1 Inspection
Water Line v.1 Inspection
Footing v.1 Inspection
Slab v.1 Inspection
Inspections - Cover No Work Until Approved v.1
Roof Nail v.1 Inspection
Okay to Wrap v.1 Inspection
Framing v.1 Inspection
Rough Electrical v.1 Inspection
Rough Mechanical v.1 Inspection
Rough Plumbing v.1 Inspection
Rough Fire Clearance Bldg v.1 Inspection
Shower Pan v.1 Inspection
Insulation v.1 Inspection
Drywall Nail v.1 Inspection
Exterior Lath v.1 Inspection
Gas Test v.1 Inspection
Sewer Connection v.1 Inspection
Inspections - Masonry v.1
Printed: 4/9/26 9:21 am Page 3 of 4
Permit Type:
Permit Number:
Property Address:
Building Residential
BRES2025-0285
54087 SOUTHERN HILLS
BUILDING PERMIT
Inspections - Electrical for Meter Release v.1
Temporary Power v.1 Inspection
Temp Use of Permanent Power v.1 Inspection
Inspections - Final v.1 06/26/2025 0:00 06/30/2025 14:10
Final Building v.1 Inspection 06/26/2025 0:00 06/30/2025 14:10
Certificate of Occupancy v.1
Certificate of Occupancy v.1 Create Report
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 4/9/26 9:21 am Page 4 of 4
February 19, 2025
Mr. and Mrs. Buck
54-087 Southern Hills
La Quinta, CA 92253
Re: 54-087 Southern Hills - Windows
Dear Mr. and Mrs. Buck,
The Architectural Committee has received and accepted the required plans and submitted documents
related to your proposed installation of the above listed variances at your 54-087 Southern Hills
residence. Currently, among the outstanding documents that we require are a City of La Quinta
Building Permit. By way of this letter the Architectural Committee submits this letter and respectfully
confirms the acceptance of this project to the City of La Quinta Department of Building and Safety.
The Association will await receipt of the aforementioned item from the city.
Cordially,
Kelly McGalliard CCAM AMS PCAM
General Manager
For the Architectural Committee
KM/bvf
PRESCRIPTIVE RESIDENTIAL ALTERATIONS THAT DO NOT REQUIRE HERS FIELD VERIFICATION
CEC-CF1R-ALT-05-E
CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022
CERTIFICATE OF COMPLIANCE
This compliance document is only applicable to simple alterations that do not require HERS verification for compliance. When HERS verification is
required, a CF1R-ALT-01 shall first be registered with a HERS Provider Data Registry.
Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CF1R-ALT-05 and CF2R- ALT-05
Compliance Documents. Possible exemptions from duct leakage testing include: less than 25 feet (ft) of ducts were added or replaced; or the
existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a HERS Rater. If space
conditioning systems are altered and are not exempt from HERS verification, then a CF1R-ALT-02 must be completed and registered with a HERS
Provider Data Registry.
Alterations that utilize closed cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R -value
greater than 5.8 per inch, or open cell Spray Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cub ic foot having an R-
value of 3.6 per inch, shall complete and register a CF1R-ALT-01 with a HERS Provider Data Registry.
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and s ign a certificate
applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall
prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be me t. Temporary labels shall not be
removed before verification by the building inspector.
Project Details
Field Name Data Entry Field Name Data Entry
Project Name Enforcement
Agency
Dwelling Address Permit Number
City and Zip Code Date Permit
Issued
BUCK CITY OF LA QUINTA
54087 SOUTHERN HLS
LA QUINTA, 92253-4642
BRES2025-0285
RETROFIT
REPLACEMENT OF
(4) WINDOWS. THIS
PERMIT DOES NOT
INCLUDE
ALTERATION OF
THE OPENINGS.
2022 CALIFORNIA
BUILDING CODES.
06/25/2025
PRESCRIPTIVE RESIDENTIAL ALTERATIONS THAT DO NOT REQUIRE HERS FIELD VERIFICATION
CEC-CF1R-ALT-05-E
CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022
A. GENERAL INFORMATION
Field Field Name Data Entry
01 Project Name
02 Date Prepared
03 Project Location
04 Building Front Orientation
(deg or cardinal)
05 CA City
06 Number of Altered Dwelling Units
07 Zip Code
08 Fuel Type
09 Climate Zone
10 Total Conditioned Floor Area (ft2)
11 Building Type
12 Slab Area (ft2)
13 Project Scope
BUCK
03 - 01 - 2025
54087 SOUTHERN HLS
NORTH
LA QUINTA
1
92253
N/A
15
3370
SFH
N/A
WINDOW REPLACEMENT RETROFIT
PRESCRIPTIVE RESIDENTIAL ALTERATIONS THAT DO NOT REQUIRE HERS FIELD VERIFICATION
CEC-CF1R-ALT-05-E
CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022
D. Fenestration/Glazing Allowed Areas and Efficiencies (Section 150.2(b)1)
Field Field Name Data Entry 1 Data Entry 2 Data Entry 3
01 Alteration Type
02
Maximum Allowed
Fenestration Area For All
Orientations (ft2)
03
Maximum Allowed West-
Facing Fenestration Area
Only (ft2)
04a
Existing Fenestration
Area for All Orientations
(ft2)
04b Existing West-Facing
Fenestration Area (ft2)
05a Maximum Allowed
U-factor (Windows)
05b Maximum Allowed
U-factor (Skylights)
06a Maximum Allowed SHGC
(Windows)
06b Maximum Allowed SHGC
(Skylights)
07 Comments
REPLACEMENT
674
168.5
80
0.30
N/A
0.23
N/A
LIKE-FOR-LIKE REPLACEMENT OF
WINDOWS
PRESCRIPTIVE RESIDENTIAL ALTERATIONS THAT DO NOT REQUIRE HERS FIELD VERIFICATION
CEC-CF1R-ALT-05-E
CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022
F.Fenestration/Glazing Proposed Areas and Efficiencies – Replace (Section 150.2(b)1B)
Note: Doors with greater than or equal to 25 percent glazed area are considered glazed doors and are treated as fenestration products.
Table F-1
Field Field Name Data Entry 1 Data Entry 2 Data Entry 3
01 Tag/ID
02 Fenestration Type
03 Frame Type
04 Dynamic Glazing
05 Orientation N, S, W, E
06 Area Removed (ft2)
07 Area Added (ft2)
08 Net Added Area (ft2)
09 Proposed U-factor
10 Proposed U-factor
Source
11 Proposed SHGC
12 Proposed SHGC Source
13 Exterior Shading Device
14 Combined SHGC from
CF1R-ENV-03
MILGARD TRINSIC - LINE 1 & 2 MILGARD TUSCANY - LINE 3 & 4
(2) WINDOW (2) WINDOW
VINYL VINYL
N/A N/A
S W
40 40
40 40
0 0
0.27 0.27
NFRC NFRC
0.22 0.22
NFRC NFRC
N/A N/A
N/A N/A
0.29
0.19
0.28
0.20
PRESCRIPTIVE RESIDENTIAL ALTERATIONS THAT DO NOT REQUIRE HERS FIELD VERIFICATION
CEC-CF1R-ALT-05-E
CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022
Table F-2
Field Field Name Data Entry
15 Net Added West-facing Fenestration Area
16 Is Net Added Fenestration Area ≤ for west-facing fenestration? ⃝ Yes ⃝ No
17 Net Added Fenestration Area (all orientations)
18 Is Net Added Fenestration Area ≤ 0 for all orientations? ⃝ Yes ⃝ No
19 Proposed Fenestration U-factor (Windows)
20 Required Fenestration U-factor (Windows)
21 Is the proposed Fenestration U-factor ≤ the Required Fenestration U-factor? ⃝ Yes ⃝ No
22 Proposed Fenestration SHGC (Windows)
23 Required Fenestration SHGC (Windows)
24 Is the Proposed Fenestration SHGC ≤ the Required Fenestration SHGC? ⃝ Yes ⃝ No
25 Proposed Fenestration U-factor (Skylights)
26 Required Fenestration U-factor (Skylights)
27 Is the proposed Fenestration U-factor ≤ the Required Fenestration U-factor? ⃝ Yes ⃝ No
28 Proposed Fenestration SHGC (Skylights)
29 Required Fenestration SHGC (Skylights)
30 Is the Proposed Fenestration SHGC ≤ the Required Fenestration SHGC? ⃝ Yes ⃝ No
0
0
0.27
0.30
0.22
0.23
N/A
N/A
N/A
N/A
PRESCRIPTIVE RESIDENTIAL ALTERATIONS THAT DO NOT REQUIRE HERS FIELD VERIFICATION
CEC-CF2R-ALT-05-E
CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022
Documentation Author's Declaration Statement
1.I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Company: Signature Date:
Address: CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Phone:
Responsible Person's Declaration Statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the
building design or system design identified on this Certificate of Compliance (responsible designer).
3.The energy features and performance specifications, materials, components, and manufactured
devices for the building design or system design identified on this Certificate of Compliance conform
to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4.The building design features or system design features identified on this Certificate of Compliance
are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval
with this building permit application.
5.I understand that a registered copy of this Certificate of Compliance shall be made available with the
building permit(s) issued for the building, and made available to the enforcement agency for all
applicable inspections.
I understand that a registered copy of this Certificate of Compliance is required to be included with the
documentation the builder provides to the building owner at occupancy.
Responsible Designer Name: Responsible Designer Signature:
Company: Date Signed:
Address: License:
City/State/Zip: Phone:
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1 -800-772-3300
BERNARD ADRI
CALIFORNIA WINDOW & DOOR 03 - 01 - 2025
75-100 ST. CHARLES PLACE
PALM DESERT, CA. 92211 760.773.1053
BERNARD ADRI
CALIFORNIA WINDOW & DOOR 03 - 01 - 2025
75-100 ST. CHARLES PLACE 906636
PALM DESERT, CA. 92211 760.773.1053
2'8"x2'1" SH WINDOW
U-FACTOR: 0.28
SHGC: 0.20
54-087 SOUTHERN HILLS
ALL CONSTRUCTION SHALL COMPLY WITH
THE 2022 CALIFORNIA RESIDENTIAL,
MECHANICAL, ELECTRICAL, PLUMBING,
GREEN BUILDING AND ENERGY CODES
AND THE LA QUINTA MUNICIPAL CODE
A PAPER COPY OF THE APPROVED PLANS
(WITH CITY-AFFIXED APPROVAL STAMPS)
MUST BE KEPT AT THE JOB SITE AT ALL
TIMES. NO EXCEPTIONS.
- NO CHANGES TO OPENINGS
- SAFETY GLAZING TO BE PROVIDED
PER CRC R308.4 - VERIFY IN FIELD
- EMERGENCY ESCAPE AND RESCUE
OPENINGS SHALL COMPLY WITH
CRC R310 - VERIFY IN FIELD
2'8"x2'1" SH WINDOW
U-FACTOR: 0.28
SHGC: 0.20
1'6"x4'7" XO WINDOW
U-FACTOR: 0.29
SHGC: 0.19
1'6"x4'7" XO WINDOW
U-FACTOR: 0.29
SHGC: 0.19
BRES2025-0285
RETROFIT
REPLACEMENT OF
(4) WINDOWS. THIS
PERMIT DOES NOT
INCLUDE
ALTERATION OF
THE OPENINGS.
2022 CALIFORNIA
BUILDING CODES.
06/25/2025