HomeMy WebLinkAboutBRER2020-0163BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Re -Roof
Permit Number:
BRER2020-0163
Property Address:
49451 GUIJARRO PL
APN:
646270034
Legal Description
Property Zoning:
Valuation:
$33,175.00
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 10/21/2020
ISSUED DATE: 10/22/2020
CALIFORNIA
Owner: GAIL JOHNSON
515 S FIGUEROA ST NO 1200, LOS ANGELES, CA
92253
Applicant: GEORGE GORDON
42790 SANDY BAY RD, BERMUDA DUNES, CA
92203
Contractor: GEORGE GORDON / 969798
42790 SANDY BAY RD, BERMUDA DUNES, CA
92203
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.Ieginfo.ca.gov/calaw.htm1.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Printed: 4/17/26 9:21 am Page 1 of 4
BUILDING PERMIT
Permit Type: Re -Roof
Permit Number: BRER2020-0163
Property Address: 49451 GUIJARRO PL
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
co
Printed: 4/17/26 9:21 am Page 2 of 4
BUILDING PERMIT
Permit Type:
Permit Number:
Property Address
Re -Roof
BRER2020-0163
49451 GUIJARRO PL
JOHNSON / RAISE AND RESET TILE RE -ROOF *** REROOF WITH CLAY TILE AT SLOPED AREAS. REMOVE CLAY ROOF TILE, INSTAL
LOW-E, 2-PLY UNDERLAYMENT, RE -INSTALL CLAY ROOF TILE. PER 2019 CALIFORNIA ENERGY CODE.
Re -Roof Area Square 4730
Footage
Type Group Sq Ft Value
Invoice No. Fee
PERM IT-BRER2020-016 RECORDS MANAGEMENT FEE
3 RE -ROOF - EA ADDITIONAL 1,000SF
RE -ROOF - FIRST 2,000SF
RE -ROOF - FIRST 2,000SF PC
TECHNOLOGY ENHANCEMENT FEE
BSAS SB1473 FEE
Total for Invoice PERMIT-BRER2020-0163
Fee Amount
Amount Paid
$10.00
$10.00
$38.64
$38.64
$54.74
$54.74
$109.48
$109.48
$5.00
$5.00
$2.00
$2.00
$219.86
$219.86
Grand Total for Permit $219.86 $219.86
Workflow Step / Action Name Action Type Start Date End Date
Inspections v.1 10/21/2020 0:00
FINAL"" v.1 Inspection
PRE -ROOF v.1 Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Printed: 4/17/26 9:21 am Page 3 of 4
BUILDING PERMIT
Permit Type: Re -Roof
Permit Number: BRER2020-0163
Property Address: 49451 GIJIJARRO PL
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
iurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the buildina official.
Printed: 4/17/26 9:21 am Page 4 of 4
79041 Delta Street
0 fl0
liCi969798
Phone: 760)565-7006
Bermuda Dunes, CA 92203 Fax: 760)200-1951
gmgordonroofing"maii.com
Name/Address
Bill & Gail Ketchum
49-451 Guijarro Drive
La Quinta, CA 92253
Proposal
Date
Pro osa! No.
05/26/20
1 1152
Project Name/Adress
49-451 Guijarro Drive
La Quinta, CA 92253
uescnpilon I Total I
ROOF REMOVAL: Tear -off one existing 2 piece mission the roof from substrate. Inspect for any
damaged plywood. Remove and replace @ $55.00 per sheet as needed. Remove all roofing debris from
property.
TILE ROOF: Install drip edge metal around perimeter of roof using electro galvanized nails. Install
Plywood @ 4 dormer vent details. Install 2-ply UDL fiberglass SBS modified underlayment mechanically
fastened to substrate with simplex type fasteners. Install 2x6 hip and ridge nailer and cover with UDL
underlayment. Install primary roof flashings to substrate with electro galvanized nails, and waterproof
using UDL underlayment. Re -install 2-piece mission roof tile and clay birdstops. Each roof tile to be
nailed to substrate using electro galvanized nails. Hip and ridge details to be mortared. Four O'Hagin
attic vents and secondary flashings to be installed with roof tile to insure proper sealing of roof
penetrations. Standard roof metal to be installed: 24" valley metal, drip edge metal, roof to wall metal, tile
pan metal, and chimney saddle metal.
LOW-E THERMAL SHEET: Install LOW-E Thermal Sheet ( Title 24 Compliant, Cool Roof Rated ). The
use of LOW-E ESP Thermal Sheet adds an insulation value of R-9-
SOLA TUBE: Install 10 inch Sola Tube @ garage roof area.
WARRANTY: Roof to receive 10 year warranty upon date of completion.
Acceptance
The Proposal described herein
Signature
Date
60 days from the above date.
33,175.00
Total $33175.
STATC OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Reid Verification Vh
J
CEC-CFIR-ALT•0rE (Revised 01119) COMMISSION CALIFORNIA ENERGY
CERTIFICATE OF COMPLIANCE ~— CF1R-ALT-05-E
Prescriptive Residential Alterations That fro Not Require HERS Field Verification
(page 8 of 8)
nioJect Name; _
PaquB oiB Date PreporeA: 2Q
—�^
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT _
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name;
—Dnrumarttatioa Author signature;
Company:
_
Signature Date;
Address;
CEA/HERS Certification Identification (If applicable):
city/state/zip:
Phone: —�
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2, 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of
Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance
documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement
agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included Ith the documentation the builder provides to the
building owner at occupancy.
Responsi signer me:
ResponsibleUesig r5' e; ,
Cnm pan
Dato Signed:
Address: •
Lk
License:
YPone:
City/SCata/ziP p �..
" 6-
^�j
For
REFLECTIVE INSULATION
SOUTHWEST DiST cIBUTION
118 S. Vinewood St.
Escondido, CA 92029
(877) 565-5693
info@lowesouthwest.com
This is a copy of email receive from EsGii Corporation regarding their approval for
LOW-E Therma Sheet to be used as an alternative Cool Roof. Please call our office if
you have any further Questions.
Sinter ly
C- `�a�-.-x►°�
Charlie Snowder
LEED AP
September 35, 2014
For reroofs located in climate zones (CZ10-15) the LOW-E 4LFLX is an acceptable
cool roof alternative for compliance with both the Prescriptive and Performance
methods for energy compliance as described in ES 1 b4.2(b)1 H. Energy Standards
150.2(b)H1 (Prescriptive) and Table 150.2-B (Performance).
Eric Jensen
EsGil Corporation
-- - r WWW.LOWEREFLECTIVEINSULATI0N.COM
LOWml:M
SOUTHWEST DISTRIBUTION
Under the previous California Residential Building Code Standards your department has been approving
the use of LOW-E THERMA SHEET as a "Cool Roof' Alternative over the past several years. With the
changes in the 2013 California Residential Building Code Standards it is our goal to ensure that building
departments have the proper documentation that allows for continued approval as stated in the new
code requirements.
Over the past six months we have worked with both third party code writers and the California Energy
Commission to ensure that our approvals are correct. The attached documents outline how LOW-E
THERMA SHEET meets the requirements listed under both the Prescriptive Exceptions and the
Performance Compliance Method.
In an effort to support your department and allow continued approvals for the contractors using LOW-E
please review the following documents:
• 2013 California Residential Building Code Standards - 2013 Prescriptive Exceptions
• Section 150.2(b) 1H1
• 2013 Performance Compliance Method
• Exception to Section 150.2(b)1H1
• California Bureau of Insulation (Certification for LOW-E Therma Sheet under Environmentally
Safe Products, Inc.)
• Department of Consumer Affairs Bureau of Home Furnishings and Thermal Insulation Article 3.
Sec. 12-13-1551
• Certificate of Compliance - Residential Performance Compliance Method for Cool Roof zones
10 —15
• Letters from end users regarding the performance of LOW-E Therma Sheet
Thank you in advance for your continued support in efforts to provide homeowners and commercial
building owners with solutions that reduce energy consumption in the most cost-effective way possible.
If you have additional questions, please call me at (760) 535-8823 or contact me via email at
charlie@lowesouthwest.com.
Sincerely,
Charlie Snowder
LEED AP
LOWmIzN
SOUTHWEST D;STRISUT!ON
CALIFORNIA RESIDENTIAL BUILDING CODE STANDARDS
(Effective July 1, 2014)
PRESCRIPTIVE EXCEPTIONS
EXCEPTION #7 - REQUIREMENT #1:
For roof alterations of residential buildings with steep -sloped roofs in climate zones 10-15, R-4 or greater (heat flow up)
insulation above the roof deck is an acceptable alternative to the roofing product requirements of_Section 150.2(b} 1Hi
of the 2013 BuildinF, Energy Efficiency Standards.
LOW-E TH ERMA SHEET (1/8" or 7/32"): When installed under a roof system that has a minimum airspace of %"
provides an R-4 (UPWARD) to the system allowing this product to meet the qualifications under the Prescriptive
Exception 47 as stated by the California Energy Commission.
REQUIREMENT #2:
Section 150.2 (b) 1H1
Insulation Certification by Manufacturers: Any insulation shall be certified by Department of Consumer Affairs Bureau of
Nome Furnishings and Thermai Insulation that the insulation conductive thermal performance is approved pursuant to
the California Code of Regulations. Title 24 Part 12 Chapters 12-13 Article 3 "Standards for Insulation Material"
LOW-E THERMA SHEET: R-4 (HEAT FLOW UP) rating meets the insulation conductive thermal performance as required
by the California Energy Commission. Additionally, ESP LOW-E products are certified by the Department of Consumer
Affairs Bureau of Home Furnishings and Insulation (listing is under Environmentally Safe Products, Inc.)
PERFORMANCE COMPLIANCE METHOD
Under roof systems without a reflective airspace the ENERGY SOFT Modeling System has verified that LOW-E TI-IERMA
SHEET (7/32") has passed the requirements of the Residential Performance Compliance Method (Zones 10-15thus
qualifying the product as a "Cool Roof" Alternative.
ESP LOW-E products are certified by the Department of Consumer Affairs Bureau of Home Furnishings and Insulation
(listing is under Environmentally Safe Products, Inc.)
LOWMI:R
REFLECTIVE INSULATION
SOUTHWEST DISTRIBUTION
The California Building Efficiency Standards Codes, Title 24
118 S. Vinewood St.
Escondido, CA 92029
(877) 565-5693
info@lowesouthwest.com
Exception to Section 150.2(b)1Hi The following shall be considered equivalent to sub -section is
a. Air -space of 1.0 inch (25mm) is provided between the top of the roof deck to the bottom of the
roofing product; or
b. The installed roofing product has a profile ratio of rise to width of 1 to5 for 50% or greater if the
width of the roofing product; or
c. Existing ducts in the attic are insulated and sealed according to section150.1(c)9; or
d. Buildings with at least R-38 ceiling insulation; or
e. Buildings with a radiant barrier in the attic meeting the requirements of Section150.1C2; or
f. Buildings that have no ducts in the attic; or
g. In Climate Zones 10-15 R-4 or greater insulation above the roof deck
WWW.LOWEREFLEC T IVEiNSULATION.COM
BEARHFTI - THERMAL INSULATION DIRECTORY
Brand
Code*
Product ID _
- - --
Material
cnJ/rr%IVAIt:
Type Primary Use
~ L DUb
Designed
for
Exposed
Apptica-
lions?
Acts as a
Vapor
Retarder?
Labeled
Thermal
Perfor-
mance
Heatflow
Up
Labeled
Thermal
Perfor-
mance
Heatflow
Down
Labeled
Thermal
Perform -
ante
Heatflow
Level
R, K or C
___ _
Environmentally Safe Produces Inc. __
ESP CLASS A WHITE 4EFWT (2, 4) FOIL/PE FOAM/FOIL rnanpnriTr. , ,
Reg CA-T2811PAj
Value
ESP ECONO-E 4EFET (4,2) FOIL/PE FOAM/FOIL
11
COMPOSITE CLG WALL FLR
TUB
YES
YUS
YES
7.60 11.74 8.58 R
ESP HOUSEWRAP 4PFNS (1) FOIL/PE FOAM/FOIL
COMPOSITE WALL
NO
NO
7.55 11.00 7.75 R
ESP LOW,E 41-r•LT (1, 2) FOIL/PE FOAM/FOIL
COMPOSITE Ct.G WALL FLR
YES
YES
4.00 R
--_ 7.55 11.00
ESP SLAB -SHIELD 4SFS8 41VSM8(5) PE FM/FOIL/PE FM
COMPOSITE FLOOR
NO
YES
7.7575 R
ESP THERMA•SHEET (5) FOIL/PE FOAM/FOIL
COMPOSITE ROOF
NO
YES
1.40
4.00 9.00 R
(1) = AVAILABLE in 4',5',6' widths
(4) = AVAILABLE in 4',6' widths
(2) = AVAILABLE with staple flange edges or EZ Seal edge
(5) = AVAILABLE in 4' widths only
(3) = AVAILABLE with staple flange edges only
" DESCRIPTION OF BRAND CODES:
ESP = ENVIRONMENTALLY SAFE PRODUCTS
BEARHFTI - THERMAL INSULATION DIRECTORY
WATER HEATER, DUCT, PINE WRAP
INSULATION MANUFACTURERS
Resigned
for
Labeled
Labeled
Exposed
Acts as a
Product
Thermal
Grand
Applica-
Vapor
Thickness
Perform-
R, N or C
Code
I product ID
Material
Type
Facing
Primaryuse
bons?
Barrier?
inches
ante
Value
Environmentally Safe Prnduets Inc
Reg CA-Ti81 PAI�
••••••- ••••-•- .�•�0 wmrIlan[ UUL1 WKAP YES YES
Available In 4',S',6' widths
R•value achieved with 1/2" .spacer around duct
DESCRIPTION Of BRAND CODES;
ESP = ENVIRONMENTALLY SAFE PRODUCTS
1998 CALIFORNIA REFERENCED STANDARDS CODE
(Fart 12. Title 24, C.C.R.)
Chapter 12-13
STAINDARDS FOR YNSLT-ATENG NfATERIAL
(See Part 6, Title 24. C.C.R.)
DEPARTWXT OF CONSC111ER AFFAIRS
Bureau of home Furnishings and Thermal Insulation
Article 3. Standards for Insulating Material
Application and Scope
See. 12-13-1551.
(a) This article establishes standards governing the quality of insulation sold within the state after September 22, 1981, including those
Properties which affect the safety and thermal performance of insulation during application and in the use intended.
(b) The provisions of ibis article shall apply only to the following types of insulating material:
1. Aluminum foil (reflective foil);
2. Cellular glass (board form):
3. Cellulose fiber (loose fill and spray applied);
4. Mineral aggregate (board form);
5. Mineral fiber (blankets, board form, loose till):
6. Perlite (loose till:);
7_ Polystyrene (board form, molded and extruded);
S. Polyurethane (board form and field applied);
9. Polvisocyanurate (board form and field applied);
10. Urea formaldehyde foam (field applies)_
,1. Vermiculite (loose fill).
(c) The provisions of ibis article shall apply to the sale of insulating material within the state. The provisions of this article shall not
apply to insulating material manufactured in California, but sold outside the state, nor to insulating material manufactured outside
California and wholesale in California for final retail sale outside the state. For the purpose of this anicle, the sale of a building or an
appliance which contains installed insulating material is not considered the sate of the insulating material.
(d) Any type of insulating material not listed in subsection (b) may be sold within California notwithstanding any other provision of
this article.
Authority cited: Sections 25920 and 25922, Public Resources Code.
Reference: Sections 25910, 25920, 25921 and 25922, Public Resources Code_
HISTORY:
1. Repealer of .articles (Sections 1551-1561) filed 8-11-78; effective thirtieth day thereafter (Register 78, No. 32). For prior history,
see Registers 76, No. 16; 78, Nos. 2 and 26.
2. New ,article 3 (Sections I551-1565) flied 1-16-79; effective thirtieth day thereafter (Register 79, No.3).
3, Amendment filed 8-10-81: designated effective 9-22-91 (Register 81, No. 33).
Definitions
Sec. 12-13-I552. For purposes of this article, the following definitions shall apply:
(a) "Approved laboratory" means any testing facility including a facility owned or operated by a manufacturer which has been
approved pursuant to Section 1554 of this article.
(b) "ANSP" means the American Rational Standards Institute.
(c) "ASTW' means the American Society for Testing and Materials.
(d) "Building materials" means materials used in walls, ceilings, roofs and floors of buildings.
(e) "Exposed application" means any interior application of the product in -vlrich it is not used in a construction assembly imposing
a material which meets the requirements of Chapter 8 of the Uniform Buldding Code in substantial contact with the facing or membrane
surface.
(1) "installed design density" means the proveri density for loose fill insulation other than cellulose which has been determined by
the manufacturcr to constitute the density whcreby scnlement of no more than 2 percent shall occur over the first three years, or no
more than 4 percent over the first 15 years of installation.
12-13-1552 1998 CALIFORNIA REFERENCED STANDARDS CODE
(Part 12. Title 24, C.C.R.)
(g) "Insulating material" or "insulation" means any material listed in Section 15511 (b) of this article and placed :within or
continuous to a wail, ceilir. roof, or floor of a room or building, or contiguous to the surface of any appliance or its intake or outtake
Mechanism, for fire purpose of reducing heat transfer or reducing adverse temperature fluctuations of the building room or appliance.
(h) "Manufacturer" means any person who either:
1. Produces insulating material in the final composition either for use in the form sold or to be further dimensionally modified; or
2. In the case of polymethane, polyisocyanurate and urea formaldehyde foam formed at the installation site, produces the primary
components of the material.
"Manufacturer" shall not include any building contractor or any other person whose sole activity is to install insulation at the
installation site.
(i) "Quality assurance program." (Reserved)
0) "Recommended wall density" means the density used for pressure fill retrofit will applications to prevent settling.
(k) "Representative sample" means a sample' of insulating mmateriai with the same characteristics (other than thickness) and using
the same facing imposed on the insulating material manufactured for final use.
(1) "Representative thickness" means a thickness of insulating material at which the change in thermal performance per inch will
vary no more than plus or minus 2 percent with increases in thickness.
(m) "TAPPI" means Technical Association of Pulp and Paper Industry.
(n) "Thermal performance" means the tested thermal conductivity, thermal conductance or thermal resistance (R-value), as
appropriate, of an insulating material.
(o) "Urea formaldehyde foam" means a cellular plastic insulation material generated in a continuous stream by mixing the
components which are a urea formaldehyde resin, air and a foaming agent.
Authority cited: Sections 25920 and 25922, Public Resources Code,
Reference: Sections 25915 (a), 25920. 25921 and 25922, Public Resources Code.
HISTORY:
1, Amendment filed 8-10-81: designated effective 9-22-81 (Register 8t, No. 33).
Quality Standards
Sec. 12-13-1553. The manufacturer shall cause the testing of samples of ursulating material for conformity with the quality Standards
described in this section.
(a) General Testing Provisions. In testing any material pursuant to this section. the following general procedures shall be used.
t. At, tests with the exception of the AINSUAASTM E 84-79 test shalt be conducted using representative samples at the representative
thickness of the insulation, except that when the final use of an insulating material entails a thickness less than the representative
thickness, then the insulating material will be tested at the lesser thickness.
2. NXtimere uniformity of product ensures consistency of test results across a product grouping, test results for one may be used for
certification of other products :within that product group. The manufacturer shall provide sufficient documentation to establish a valid
basis for applying a particular test result to other products within the group.
The Executive Director shall determine whether a valid basis exists for grouping products for testing pursuant to this subsection. If it
is determined that a valid basis does not exist, individual tests shall be required. A manufacturer may appeal the Executive Director's
determination to the full Commission.
3. Thermal performance of building insulations snail be stated in R-value. Other insulations shall use thennat conductivity. con-
ductance, or R-value as appropriate.
4. All thermal performance tests shall be conducted on materials which have been conditioned at 73.4' + 3.6'F and a relative
humidity of 50 ± 5 percent for 24 hours immediately preceding the tests. The average testing temperature shall he 75' = 2'F with at least
a 40'F temperature difference.
S. Aluminum foil insulation shall be tested according to ANSI/ASTt+n C 236-66 to determine the thermal performance in horizontal,
upward and downward directions. The tested thermal performance in the heat -flow direction or directions of the intended application
shall be labeled on the material. The manufacturer shall test once in each direction of intended application. except that for products
labeled with only one heat -flow direction, the manufacturer shall test two samples in that direction.
6. Insulation (other than aluminum foil insulation materials) for which additional value is claimed for facings and air spaces shall be
tested for thermal performance as a material :without the air space pursuant to this article. The manufacturer may elect to report
additional thermal performance values of a given construction tested according to ANSI'AS M C 236-66 for that construction as long as
full details of that construction are also disclosed in the certification statement and pursuant to Section I557 (c) of this article. If a
manufacturer elects to report a thermal performance value for a material plus an air space (as supplemental information to the required
material thermal performance), but not necessarily for a full construction, the manufacturer must also disclose the conditions of the test
and the limitations to the attainment of that result.
r. Except as provided in Items 5 and 6, the thermal performance test results certified under Section 1555 of this article shall be the
average of the values obtained from at least three tests.
12-13-1553 1498 CA IFOICNIA REFERENCED STANDARDS CODE;
(Part I2. Title 24, C.C.R.)
8. The average measured thermal performance of the tests required by Items 5, 6 and 7 shall not be more than 5 percent below the
value specified on the product. In addition, all insulation material sold within the state after September 22, 1981. shall have a measured
thermal performance not more than 10 percent below the value specified on the product.
9Ali numbered test descriptions shall be contained in the document "Test Descriptions for Insulating Material" dated February 27,
i98i.
10. Facings on representative samples may be removed or modified by slitting for the ANSIlASTM C 1 77- 6 and ANSFASTM C
518-76 tests.
11. All thermal performance testing equipment used for testing insulating materials shall be calibrated with samples referenced to the
United States National Bureau of Standards.
12. Manufacturers of loose fill insulations for which no settled density test is required by this section shall be required to include the
installed design density in the identifying information described in Section 1557, The manufacturer shall provide sufficient
documentation to establish a valid basis for the determination of installed design density.
The Executive Director shall determine whether a valid basis exists for the installed design density claimed by the manufacturer. If it is
determined that a valid basis does not exist. the director may assign an appropriate installed design density or may require an appropriate
tear to determine Elie installed design density. The manufacturer may appeal the Executive Director's determination to the full
Commission.
13. Within 180 days after the availability of appropriate representative thickness calibration samples from the National Bureau of
Standards, all insulating materials thicker than I inch. which have not previously been tested at the representative thickness of a
representative sample, shall be tested at representative thickness and recertified. Test resuits and a revised certification statement will be
submitted to the Executive Director. The Executive Director shalt determine if and when an appropriate representative thickness
calibration sample is available from the rational Bureau of Standards and shall publish a list of available representative thickness
calibration samples. The manufacturer may appeal the Executive Directors determination to the full Commission.
14. All products which may be used for pressure fill retrofit wall application shall be separately tested for thermal perfomiance using
a sample prepared at the manufacturer's recommended wall density for such applications.
15. All water heater insulation kits and nor.prefonned pipe insulation shall be tested for thermal performance thermal performance at
the installed compressed thickness of a typical application. Installed compressed thickness shall be determined according to Test
Description Number 6. All nonpreformed duct insulation shall be labeled, in accordance with Section 1557(c), with an installed R-value
equal to the R-value of the uncompressed insulation times 0.75.
(b) Aluminum Foil.
1. Composition. The insulation shall have uniform flat surfaces and shall not be crimpled, torn or punctured. Aluminum foil shall
contain not less than 99 percent aluminum. Kraft paper and flangeboard shall meet the requirements of ANSL T APPI T400 0575.
Faangeboard used for more than two insulation layers shall be of28 point grade minimum, if single sheet flangeboard is used or 1' point
grade minimum if double sheet flangeboard is used.
Adhesive used in bonding shall be waterproof and shall show no sign of bleeding when tested in accordance vrith the following test
procedure. Bleeding at cut edges may be disregarded.
Specimens for tests shall consist of pieces of insulation cut to approximately 3 by 6 inches, suspended in a vertical position and
heated to a temperature of t 30'F _ 5'F for at least five hours. At the end of heating period, examine the reflective surfaces to determine
whether the adhesive has bled or extruded through the surface, or detammnation has occurred.
2. Thermal performance. Thermal performance shall be determined according to ANSVASTM C 236-66. The test panel shall
consist of a panel utilizing a N ooden frame of 2 by 6 inches construction covered with 3/4-inch plywood on both sides. The resultant
thermal performance shall be based on the insulation only.
3. Size. Layers of insulation composed of unsupported foil that is exposed shall have a minimum thickness of 0.000# inch. Unsup-
ported foil that is sandwiched in a multilayer sheet shall have a minimum thickness of 0.00035 inch. Foil bonded to kraft paper shall
have a minimum thickness of 0.00025 inch. Minimum space between layers of a multilayer sheet shall conform with the United States
General .Services Administration insulation standard HH-I-I252B dated August 18, 1976.
4 Resistance to combustion. Surface-buming characteristics shall be determined according to time ANSUASTIvi E 84-79, and shall
not exceed the following values:
Flamespread.....................................................................................?5
Smokedeveloped.............................................................................50
5. Pliability. Foil shall be folded and the folded edge smoothed using a light finger pressure. The finished insulation shall not crack
when folded to 180' bend at a temperature of 70' ± 2'F and a relative humidity of 50 ± 5 percent.
(c) Cellular Glass in Board Form.
I . Composition. The material shall consist of a glass composition which has been 'named or cellulated under molten conditions.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Thermo Sheet Study
Calculation Description :Title 24 Analysis
Calculation Dateffime:os:18, Mon, Jan 06, 2014
Input File Nan'te: EPExisting2.ribd
CF1 R-PRF-02-E
Page 1 of 10
(zE.LE'RAI-. iNF= F PJ!.T.19L1
01
Proiecl Name
'fherma Sheet Study
02
CiACUlallon Description
Till(,, 24 Analysis
03
Project location
04
(%A City
OS
Standards Version
Compliance 2o'15
06
4
Zip code
07
_
Complianco Manager Version
BEMCmpMgr2013-1d (522)
08
Climate Zone
CZ10
09
Softwaro Version
CBECC-Res 2013-1d (522)
10
Building Type
Single Family
11
Front Orientation (deglCardinaf)
0
12
�14
Project Scope
Addition andlor Alteration
13
Number of Dwelling Unils
1
lotal Cond. Floor Area (Fi2)
2100
15
Number of Zones
1
16
81ab Aren (Fr2)
2100
17
Number of Slones
1 — �y
18
� Addition Conti, Floor Area
NA
f 9
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
NA
21
Glazing Porcenlage
(%)
20,0 ,
COMPLIANCE RESUI:rS
Detailed help on using the CF-1R Certificate of
Compliance is available via the Internet by either
scanning the QA code or browsing to
di11); 11;,^rg!^✓ _Jrte?�nerciv c1�� �i� i12�1hefp!:(j.r.a l,,x
J
01
_
Building Complies with Computer Porformance
02
This building incorporates features that require field testing andlor verification by a corlified HERS rater under the supervision of
a CFC-approved f iERS provider.
03
This building incorporates one or more Special Features shown below
CNERGYLi SUMMARY
04
05
06
07
08
f Here Use
Jy
{kTDVifie yr}
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Irnprovemon)
Space Heating
7,66
6.76
0,90
11.7`;P
Space Cooling
(i4.80
54.85
-0.05
-0.1%
iAQ Ventilation
1.08
1.08
0.00
Water Flealing
13.47
13.47
0.00
Photovoltaic Offset
0.00
O.Od
TOTAL
77.01
76.16
0.8 i
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF]IR-12101.3-504
Report Gencrrateti at 1/6/2014:9:19:09 AM
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-02-E
Project Name: Therma Sheot Study
Calculation Description :Title 2.4 Analysis
Calculation Date/Time:09:19, Mon, Jan 06, 2014
Input File Name: EPExisting2sjbd
Rage 1 of 10
01
Project Name
Therma Sheet Study
02
Calculation Description
Title 24 Analysis
03
Project Location
04
CA City
05
Standards Version
Compliance 2015
06
Zip code
_
07
Compliance Manager Version
BEMCntptr4gr 2013.1d (,522)
08
Climate Zone
CZ11 _
09
Software Version
CI3ECC-Res 2013 1d (622)
10
P,uilding'llype
Single Family
11
Front Orientation (deg/Cardinal)
0
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2.100
15
Number of Zones
1
16�
Slat? Area (FI-2)
2100+
17
Number of Stories
1
18
Addition Cond. Floor Area
NA
19
Natural Gas Available
Yes
20
Addition Slab Aroa (FT2)
NA
21
Glazing Percentage (%)
20.01
COMPLIANCE RESULTS
Detailed help on using the CF-1R Certiilcale of
Compliance is available via the Internet by either
scanning the OR code or browsing to
k:_tL3Jfyw�.;[jtlfi2�ie,yc;Xcy��ndl��tg'il?�a!y1!�i; r a4�x
h
01
Building Cornplies with Computer Performance
02
This building incorporates fcdtures that mcluire, field testing and/or verification by a certified HERS rater under the supervision at
a CEC-approved HERS provider.
03
This building Incorporates one or more Special features shown below
ENERGY USE: SUMMARY
04
05
06
07
08
Energy Use
(kTOV/f(2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space beating
24.12
22.95
1.17
4.9%
Space Cooling
83.58
82.93
0.135
0.81/.
lAQ Ventilation
1.13
1.13
0.00
0.0%
Water Healing
13.56
13.56
0.00
0.01%
Photovoltaic Offset
0.00
~^ 0.00
_ ----
TOTAL
122.39
120.57
1.82
_ L510
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - Cf iR-121013.504 Report Generated at 1/b/2014:9:20:56 AM
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-02•-E
Project Name: Thernla Sheet Study
Calculation Description :Title 24 Analysis
Calculation Date/Time:09:21, Mon, Jan 06, 2014
Input File Name: EPExisting2.ribd
Page 1 of 10
Gl�rVE!?,6LityFct?t�rnnTloN_--
01
Project Nrarne
Therma Sheer Sludy
02
Calculation Description
Title 24 Analysis
03
Project Locution
_
-
04
CA City
05
Standards Version
Compliance 2015 y
06
Zila codo
07
� � Compliance Manager Version
t7EMCnapMgr 2013•1d (5221)
08
Climate Zone
CZ12
09
Software Version
CBECC-Res 2013-1d (522)
10
building Type
Single Family
11
Front Orientation (deg/Cardinal)
0
12
Project Scopo
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2100
15
Number of Zones
1
16
Slab Area (FT2)
2'100
17
M Number of Stories
1�
18
Addition Cond. Floor Area
NA
19
Natural Gas Available,
Yes
20
Addition Slab Area (FTC)
NA
21
Glazing Percentage (%)
20.0`;4,
COMPLIANCE RESUI.TS
Detailed help on using the CF-1 R Certificate of
Compliance is available vita the Internet by either
scanning the OR code or browsing to
Elk;t,�v. a ninghrle;_{lycode, erg browsing
rtr.nsi,r.
wr
• .
01
_
Building Complies with Canaputer Per-formance
02
'this building incorporates fe;•ahrres that require field testing and/or verification by a certified HERS rater under the supe vision of
a GEC -approved HEfR provider.
03
This building incorporates one or more Special Fealures shown below
V
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(I(TDV/tt2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvements.
apace Heating
2.6.46)
25,02
1.44
5.4
Space Cooling
49.69
49,97
-0.28
-0.6%
IAQ Ventilation
1.13
1.13
0.00
0.0%
Wafer Heating
13.86
Y 13,86
0.00
0.0
Pholovoltaic Offset
----
0.00
0.00
TOTAL
91.14
89.98
1.16
1.3%
Registration Number: Registration Date/Time: HERS provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1.R-12.1013-504 Report Generated at 1/6/201.4:9:2.. 36 AM
CERTIFICATE OF COMPLIANCE - RESIDENTIAL. PERFORMANCE COMPLIANCE METHOD
Project Name: Therrna Sheet Study
Calculation Description :Title 24 Analysis
Calculation Dateffilne:os:23, Mon, ,pan 06. 2014
Input File Name: EPExisting2.ribd
CF1 R-PRF-.02-E
Page 1 of 10
01
Project Name
Therrna Sheet Study
02
Calculatian Description
TWO 24 Analysis
03
Proiecl Location
04
CA City
05
Standards Version
Compliance 2o15
06
Zip code
07
~� Compliance Manager Version
l3EMCmpMgr 2013-1d (522)
08
Climate lone
CZ13
_
09
Software Version
CBECC-Res 2013.1d (522)
10
Building Type
Single family
11
Front Orientation (deg/Cardinal)
0
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT'_>)
2 t00
15
Number of Zones
t
16
Slab Area (F 1"2)
2100
17
Number of Stories
1
18
Addition Cond, Floor Area
NA
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
NA
21
Glazing Percentage (°L)
20.0% Y
COMPLIANCE RESULTS
Detailed help on using the CF-f R Certificate of
Compliance is available via the Internet by either
scanning the QR code or browsing to
lwv.w�tlg, jrl�rrori pr!j ;fit grp4 f;1 t,p
al _r
El cr 1 rrl �{'
9
01
Building Complies with Computer Performance
02
This building incorporates features that require field lesfing and/or vorilication by a ccrlifiod HERS rater under the supervision oftldl
a CEO -approved HEFTS provider.
03
This building incorporate, one or more Special Features Shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(krDvnte•yrj
Standard
Design
Proposed
Design
Compliance
Margin
Percent
improvement
Space Heating
22.61
21.36
1.25
_
5.5%
Spare Cooling
88.5 5
88.75
-0.20
•0.2
IAQ Ventilation
1.13
^
1.13
0.00
0.0%
Water Heating
13.44
13.44
0.00
0.0%
Photovoltaic Oftt:oi
0.00
0.00
— --
TOTAL
125.73
124.68
1.05
0.8" ,,
Registration Number. Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R.12.1013-504 Report Generated at 1/6/2014:9:24:22 AM
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-02-E
Project Name: Therma Sheet Study
Calculation Description :Title 24 Analysis
Calculation Date/Time:09:25, Mon, Jan 06,2014
Input File Name: EPExisting2xibd
Page 1 of 10
01
Project Name
Therma Sheet Study
02
Calculation Description
Title 24 Analysis
03
ocation
04
CA City
05
Standards Version
compliance 2015
06
Zip code
07
Compliance Manager Version
BEMCr-npMgr20l3-1d(522)
Climate Zone
CZ14
09
Software Version
CBECC-Res20i3-1d(522)
10
Building Type
Single Family
11
Front Orientation (deg/Cardlrial)
0
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
16
Total Cond. Floor Area (F'V2)
M Siab Area (FT2)
2100
15
Number ol'Zones
-1
2100
17
Number of Stories
I
18
Addition Cond. Floor Area
NA
19
Natural Gas Available
Yes
20 Addition Slab Area (FT2) NA
COMPLIANCE RESULTS
Building Complies with Computer Performance
21
Glazing Percentage
Detailed help an using the CF- I R Certificate
Compliance is available via the Internet by either
scanning the OR code or browsing to
hjtfp-:INAwWjitiv 04onpFM�ode ip x.
In
- 0
;J
02
incorporates features Thiat 11�ultl field 7testing and/or verification b;a certified HERS rater under the supervision of
a CEC-approved HERS provider.
—1110.
03
This building incorporates one or Special Features -shown —below
ENERGY USE SUMMARY
04
-'--T-07
06
---T—
08
Energy Use
(I(TDVIft2 _yr)
'7—p7,op,,—T--EompIan�e
S landard
Design
Proposed
Design
Margin
Improvement
Space Heating
21.2
19.74
1.47
Space Cooling
76.87
76.65
0.2.2
7. 3
IAQ Ventifation
1.08
1.08
0.00
0,0%
Water Heating
13.72
13.72
0.00
0.0%
Photovoltaic Offset
----
IOTAL
112.88
1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 201.3 Residential Compliance Report Version - CFIR-121013-504
Report Generated at 1/6/2014:9:25:59 AM
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Narne: Therma Sheet Study
Calculation Description :Title 24 Analysis
Calculation Date/Tirne:09:26, Moll, .Jan 06, 2014
Input File Name: EPExisting2.ribd
CF1 R•PRF-02-E
Page 1 of 10
01
Project Name
Thermo Sheet Study
Title 24 Analysis
�-
05
� � Standards Version
— --
Compliance 2015
na
Calculation Description
03
Project Location
04
� GA City
06
tl0
10
Zip code
Climate Zone
Building Type
C215
Single Family
07
09�
11
Compliance Managor Version
Software Version
Front Oriontatiorr (deg/Cardinal)
BEM(,mpMgr 2013-1d (522)
CBECC-Res 2013-1d (522)
0
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
i
14
Total Cond. Floor Area (FT2)
2100
15
Number of Zones
16
Slab Area (FT2.)
2100
17
Number
of Stories
1�
10
Addition Cond. Floor Area
NA
_
19
Natural Gas
Available
Yes
20
Addition Slab Area (FT2) NA
^ COMPLIANCE RESULTS
21
Glazing Percentage
Detailed help on using lire CF-1 R Certi:icate of
Compliance is available via the Internet ay either
011S<scanning the QR code or browsing to
1titi:
rWE .1 }
�e
�J
L_J
01
Building Complies with Compuler Performance
02
This building incorporates lectures that require field testing and/or verification by n certified HC Ft8 rater under the supervision of
a GEC -approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(kTUV/ft''-yr)
- —
Standard
Design
Proposed
Design
Compliance
Margin
F,a
,.rcent
Improvement
space Pleating
1,12
0.89
0,23
20.5%
Space Cooling
163,46
_
162.63
0.83
0.5%.
IAO Ventilation
_ 1.09
1.09
UAO
0.0ao
Water Fleeting
11.92
1 1.92
0,00
0 Oao
Photovoltaic Offset
....
0.00
11,0p
TOTAb
177,59
176.53
1.06
0.696
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-121013-504
Report Generated at 1/6/2014:9:27:40 AM