BPOL2025-0165BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 08/20/2025
ISSUED DATE: 09/05/2025
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Pool
44585 MARGUERITE CT
BPOL2025-0165
604252039
Lot 59 MB 223/22 TR 24208
$10,000.00
RL, 59
Owner:Lauren Marquis
Applicant:Fred Esparza
PO BOX 790, CATHEDRAL CITY, CA 92235
Contractor:Fred Esparza / 924163
PO BOX 790, CATHEDRAL CITY, CA 92235
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 4/17/26 2:28 pm Page 1 of 3
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2025-0165
44585 MARGUERITE CT
BUILDING PERMIT
MARQUIS / RE-PLASTER TO EXISTING POOL & SPA ALONG WITH NEW POOL EQUPMENT TO REPLACE EXISTING AT REAR YARD. THIS
PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED
AS NOT A PART OF. APPROVED SITE PLAN REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY
FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING
CODE.
Use of Permit
Construction Details
N/AEngineer of Record 0Quantity of Detached
Spa(s)/Water
Feature(s)
0BBQ Electrical (EA)
0Number of Gas
Outlet(s)
0Mechanical Equipment
Relocation (QTY)
0Garden Wall Linear
Foootage
0Combination Retaining
Wall Linear Footage
0Total Wall Length
(Linear Footage)
RLZoning
LDRGeneral Plan Within La Quinta LimitsCity Limits TR 24208Subdivision Name
59Lot Number 1213.94Lot Size 90930Centerlines
Lot 59 MB 223/22 TR
24208
Legal Description
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
INV-00017233 $1.00 Building Standards Administration $1.00
$129.79 Swimming Pool / Spa PC $129.79
$12.00 Digital Archiving and Records Management Fee - OTC $12.00
$238.58 Swimming Pool / Spa $238.58
$18.42 Technology Enhancement Fee $18.42
$399.79 $399.79 Total for Invoice INV-00017233
Grand Total for Permit $399.79 $399.79
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Application Completeness Check v.1 08/20/2025 12:18
Submittal Document Verification v.1 Generic Action 08/20/2025 12:18
Plan Check v.1 08/20/2025 0:00 09/04/2025 7:53
Building Review (1 Day) v.1 Receive Submittal 08/20/2025 0:00 08/21/2025 14:56
Building Review (1 Day) v.2 Receive Submittal 09/03/2025 0:00 09/04/2025 7:53
Permit Issuance v.1 09/04/2025 7:54 09/05/2025 10:37
Verify Contractor info & Conditions have been met v.1 Generic Action 09/04/2025 7:54
Verify & Invoice Fees v.1 Generic Action 09/04/2025 7:54
Verify Fee Payment & Issue Permit v.1 Generic Action 09/05/2025 10:37
Print, Attach, and Email Building Permit v.1 Create Report 09/05/2025 10:36 09/05/2025 10:37
Pool Permit Inspection v.1 09/05/2025 0:00
Printed: 4/17/26 2:28 pm Page 2 of 3
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2025-0165
44585 MARGUERITE CT
BUILDING PERMIT
Pre-Gunite v.1 Inspection
Underground Plumbing v.1 Inspection
Underground Electrical v.1 Inspection
Underground Gas v.1 Inspection
Deck Bond v.1 Inspection
Pre-Plaster v.1 Inspection 09/05/2025 0:00 09/08/2025 12:39
Footing v.1 Inspection 09/19/2025 0:00 09/22/2025 11:00
Footing v.2 Inspection 09/22/2025 0:00
Bond Beam v.1 Inspection
Inspections - Final v.1 09/18/2025 0:00 09/22/2025 11:00
Final Pool v.1 Inspection 09/18/2025 0:00 09/19/2025 13:17
Final Pool v.2 Inspection 09/19/2025 0:00 09/22/2025 11:00
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 4/17/26 2:28 pm Page 3 of 3
EXISTING
RESIDENCE
EXISTING
DRIVEWAY
EXISTING
POOL
EXISTING POOL
EQUIPMENT TO BE REPLACED
BY NEW EQUIPMENT
PROPERTY
LINEPROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
EXISTING 6'
HIGH CMU WALL
EXISTING 6'
HIGH CMU WALL
EXISTING 6'
HIGH CMU WALL
N
NOTES:
-A LICENSED ENGINEER OR SURVEYOR SHALL STAKE THE PROPERTY
CORNERS OF THE SUBJECT LOT, AT THE TIME OF THE UNDERGROUND
PLUMBING INSPECTION, AND PRIOR TO CALLING FOR ANY FOOTING
INSPECTIONS FOR THESE PROJECTS, THE CONTRACTOR SHALL PROVIDE
STRING LINES ALONG THE PROPERTY LINES ADJACENT TO THE
PROPOSED WALL LINES OF THE NEW CONSTRUCTION."
POOL EQUIPMENT
Filter:
Pump:
Heater:
Lights:
Transformer:
Remote/Automation:
Cleaner:
Purification:
Booster Pump:
Fountain Pumps:
Fountains:
Electrical
Electrical run Approx. 25 linear feet With 1" PVC conduit , & (4) #8 copper THWN Wires to GFCI Protected Pool Equipment
(2) - pool 24 watt lights With 100' cords / (1) - 12 Watt Spa Light With 100' Cord
J-box to be located within 50' of pool/spa lights
L.V. lights use 1 1/2" PVC pipe a min. of 12" to a 1" conduit running to the J- box
No bonding wire, wet niche or grounding wire required for ( L.V. lights )
Minimum of 30" working clearance at the pool sub panel board
Standard 50 amp panel with overcurrent protective device (circuit breaker) at least equal to or greater than the circuit voltage
One outlet at equipment, all outlets to be GFCI protected, Tamper Resistant, Weather Resistant, and provided with an “in-use” type
cover.
14 volts to LED transformer for low voltage lights, supply & install 300 watt transformer & Label breakers when applicable
Minimum of 30" working clearance at the pool sub panel board
Plumbing
Use sweep elbows 10" minimum prior to pump Pool equipment shall be anchored to concrete pad
Gas Line runs to Pool Equipment
PVC pipes should be painted to protect them from ultraviolet rays
Heater shall be 4' from an opening window
"Shade" plumbing trenches after inspection if rocky soil is present
A gas shut-off valve is required outside of, and within 3 feet of the heater
Skimmer and auto fill with clear "pour a lids"
Verify skimmer location for common wind flows direction, not in any raised areas
Stub plumbing for solar heating with valves- (see homeowner)
A length of plumbing ( 36" min.) between the filter and the heater to allow for future solar heating
2.5" suction and 2" return lines min. for pool with directional inlets that adequately mix the pool water
See H.O. for separate suction line and valve for pool cleaner in zero elevation .
Plaster /start-up to install pool sweep safety cover
All gas lines under slabs, and/or foundations, shall be sleeved per the 2018 UPC section 1210.1.6
Gas line installed underground under roof structure shall be installed as per ( CPC 1210.16).
Hose bib to comply with ISPC 306.9.1
Water supply must be protected from backflow ISPC 302.5.
Salt system- See homeowner
Notes
Final equipment location per homeowner to meet local codes
3.Pool area to be fenced and alarms per local ordinance gates to be self
closing and self latching , gate latch to be min. of 54" above grade per
local codes.
SWIMMING POOLS AND SPAS SHALL HAVE:
At least two circulation suction outlets per pump and separated at least 3' apart,
and covered with anti- entrapment grates conforming to ASNI/APSP-16
standard
Filtration flow rate
Pool Volume =( gpm) OR, 36 gpm, whichever is Greater
No construction within any easements.
MUST MAINTAIN EXISTING DRAINAGE: TO DRAIN AWAY FROM HOUSE AND
POOL
CONTRACTORS SHALL PROVIDE, IMPLEMENT AND MAINTAIN EROSION AND
SEDIMENT CONTROL MEASURES DURING CONSTRUCTION
360
NotesSee homeowner- For exact equipment location prior to plumbing
Pool equipment shall not block the only access to mechanical equipment
4.Prior to start of every phase of construction verify with homeowner materials,
locations, and options
Soil report or additional engineering that may be required - By H.O.
BMP/Storm Management Plan Prepared Required - By H.O.
Tractor Access- See homeowner, rebuild walls and replace fence & reverse gates to meet local codes
Variable speed pump operates at below 50 decibels
All elevations are approximate. Verify heights and elevations prior to building
See local codes for possible P-Trap
See homeowner for colors and materials prior to start
Outdoor pools/spas equipped with gas or electric heater shall also be equipped with a pool/spa cover.
The cover should be fitted and installed during the final inspection
Outdoor lighting: All luminaries mounted to the building or to other building or to other buildings on
the same lot shall be high efficacy luminaries or must be controlled by a motion senor And controlled
by one of these: Photocontrol or Astronomical time clock or Energy management control system
(EMCS)
A time switch or similar control mechanism shall be installed as part of a pool water circulation control
system that will allow all pumps to be set or programmed to run only during the off-peak electric
demand period and for the minimum time necessary to maintain the water in the condition required by
applicable public health standard
All metal within 5' of water edge must be bonded
1. This is a conceptual construction drawing does not detail all construction
items. The property owner and/or contractor shall determine all final dimensions
and construction details. Homeowner or contractors are responsible for all
necessary building permits.
3. In field adjustments may be required verify any changes with homeowner
2. This is not a surveyed plan and only shows dimensions given by homeowner.
Property measurements should be confirmed with a licensed land surveyor if
required.
Safety
1. Exit alarms on the private single family home's doors that provide
direct access to the swimming pool or spa
2. An alarm that, when placed in the pool or spa will sound off if it detects an
unauthorized or accidental entrance to the water
Swimming pool heating as per 2019 residential compliance manual sec. 5.7
swimming pool and spa heating
. Any new or replacement gas or electric swimming pool heater system in a
residential occupancy shall be equipped with all of the following:
. An On-Off switch mounted on the outside of the heater for easy access
. A permanent weatherproof plate or card, easily readable, giving instruction
for the efficient operation of the swimming pool.
. Pool and spa heaters may not have continuously burning pilot lights.
Contractors shall meet or exceed
all local codes and engineering
.2022 California building code volumes 1&2
. 2022 California Mechanical Code
. 2022 California Electrical Code
. 2022 California Existing Buildings Codes
. 2022 California Fire Codes
. 2022 California Energy Codes
. 2022 California Residential Building Codes
. 2022 California Green Building Standards Code
. 2022 California Historical Building Code
Pool Guard Model PGRM-2 Pool Alarms per code NSF certified to the
ASTM safety specification F2208 (1) for pool, (1) for spa. Pool equipment
to be GFCI protected. 1" Schedule 40 electrical conduit w/ (4) #8 AWG
THWN Copper wires 18" deep min., 50 AMP sub panel @ equipment on
a 40 AMP GFCI Breaker. 1 1
2" poly gas line w/ 12 gauge yellow tracer wire
to 3
4" stub @ equipment 18" deep min. (e) 6' high access gate shall open
outwards away from the pool and shall be self-closing and have a
self-latching device. Techko model S189A door alarm per code UL 2017
at all doors that lead to the pool. #8 bond wire to be connected at 4 points
of the pool waterline.
. 2022 California Plumbing Building Code
REVISIONS BY
If any ERRORS, DISCREPANCIES or OMISSIONS
appear in the drawings, specifications or other
contract documents, the GENERAL CONTRACTOR
shall notify the Designer in writing of such error or
omission.
In the event that the GENERAL CONTRACTOR
fails to give such notice before construction and/ or
fabrication of the work, THE GENERAL
CONTRACTOR WILL BE HELD RESPONSIBLE to
the result of any errors, discrepancies or omissions
and the cost of rectifying the same.
JOSUE MUNOZ
C H E C K E D
D R A W N
D A T E
SCALE: 1/8"=1'
A-1
SITE PLAN
DRAFTER:
JOSUE MUNOZ
442-471-7317
PLANCOREINFO@GMAIL.COM
85085 CALLE FELIZ
COACHELLA CA 92236
8/19/25
44
5
8
5
M
A
R
G
U
E
R
I
T
E
C
T
LA
Q
U
I
N
T
A
C
A
9
2
2
5
3
MARQUIS / RE-PLASTER TO EXISTING POOL & SPA ALONG
WITH NEW POOL EQUPMENT TO REPLACE EXISTING AT REAR
YARD. THIS PERMIT DOES NOT INCLUDE EQUIPMENT
ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD
HAVE CLEARLY NOTED AS NOT A PART OF. APPROVED SITE
PLAN REQUIRED TO BE ONSITE FOR INSPECTION. TWO
DROWNING PREVENTION SAFETY FEATURES AND THE
REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER
INSPECTION. 2022 CALIFORNIA BUILDING CODE.
09/03/2025Taylor Tuvell
BPOL2025-0165