Loading...
BPOL2025-0165BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 08/20/2025 ISSUED DATE: 09/05/2025 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 44585 MARGUERITE CT BPOL2025-0165 604252039 Lot 59 MB 223/22 TR 24208 $10,000.00 RL, 59 Owner:Lauren Marquis Applicant:Fred Esparza PO BOX 790, CATHEDRAL CITY, CA 92235 Contractor:Fred Esparza / 924163 PO BOX 790, CATHEDRAL CITY, CA 92235 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 4/17/26 2:28 pm Page 1 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2025-0165 44585 MARGUERITE CT BUILDING PERMIT MARQUIS / RE-PLASTER TO EXISTING POOL & SPA ALONG WITH NEW POOL EQUPMENT TO REPLACE EXISTING AT REAR YARD. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED AS NOT A PART OF. APPROVED SITE PLAN REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Use of Permit Construction Details N/AEngineer of Record 0Quantity of Detached Spa(s)/Water Feature(s) 0BBQ Electrical (EA) 0Number of Gas Outlet(s) 0Mechanical Equipment Relocation (QTY) 0Garden Wall Linear Foootage 0Combination Retaining Wall Linear Footage 0Total Wall Length (Linear Footage) RLZoning LDRGeneral Plan Within La Quinta LimitsCity Limits TR 24208Subdivision Name 59Lot Number 1213.94Lot Size 90930Centerlines Lot 59 MB 223/22 TR 24208 Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00017233 $1.00 Building Standards Administration $1.00 $129.79 Swimming Pool / Spa PC $129.79 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $238.58 Swimming Pool / Spa $238.58 $18.42 Technology Enhancement Fee $18.42 $399.79 $399.79 Total for Invoice INV-00017233 Grand Total for Permit $399.79 $399.79 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 08/20/2025 12:18 Submittal Document Verification v.1 Generic Action 08/20/2025 12:18 Plan Check v.1 08/20/2025 0:00 09/04/2025 7:53 Building Review (1 Day) v.1 Receive Submittal 08/20/2025 0:00 08/21/2025 14:56 Building Review (1 Day) v.2 Receive Submittal 09/03/2025 0:00 09/04/2025 7:53 Permit Issuance v.1 09/04/2025 7:54 09/05/2025 10:37 Verify Contractor info & Conditions have been met v.1 Generic Action 09/04/2025 7:54 Verify & Invoice Fees v.1 Generic Action 09/04/2025 7:54 Verify Fee Payment & Issue Permit v.1 Generic Action 09/05/2025 10:37 Print, Attach, and Email Building Permit v.1 Create Report 09/05/2025 10:36 09/05/2025 10:37 Pool Permit Inspection v.1 09/05/2025 0:00 Printed: 4/17/26 2:28 pm Page 2 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2025-0165 44585 MARGUERITE CT BUILDING PERMIT Pre-Gunite v.1 Inspection Underground Plumbing v.1 Inspection Underground Electrical v.1 Inspection Underground Gas v.1 Inspection Deck Bond v.1 Inspection Pre-Plaster v.1 Inspection 09/05/2025 0:00 09/08/2025 12:39 Footing v.1 Inspection 09/19/2025 0:00 09/22/2025 11:00 Footing v.2 Inspection 09/22/2025 0:00 Bond Beam v.1 Inspection Inspections - Final v.1 09/18/2025 0:00 09/22/2025 11:00 Final Pool v.1 Inspection 09/18/2025 0:00 09/19/2025 13:17 Final Pool v.2 Inspection 09/19/2025 0:00 09/22/2025 11:00 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 4/17/26 2:28 pm Page 3 of 3 EXISTING RESIDENCE EXISTING DRIVEWAY EXISTING POOL EXISTING POOL EQUIPMENT TO BE REPLACED BY NEW EQUIPMENT PROPERTY LINEPROPERTY LINE PROPERTY LINE PROPERTY LINE EXISTING 6' HIGH CMU WALL EXISTING 6' HIGH CMU WALL EXISTING 6' HIGH CMU WALL N NOTES: -A LICENSED ENGINEER OR SURVEYOR SHALL STAKE THE PROPERTY CORNERS OF THE SUBJECT LOT, AT THE TIME OF THE UNDERGROUND PLUMBING INSPECTION, AND PRIOR TO CALLING FOR ANY FOOTING INSPECTIONS FOR THESE PROJECTS, THE CONTRACTOR SHALL PROVIDE STRING LINES ALONG THE PROPERTY LINES ADJACENT TO THE PROPOSED WALL LINES OF THE NEW CONSTRUCTION." POOL EQUIPMENT Filter: Pump: Heater: Lights: Transformer: Remote/Automation: Cleaner: Purification: Booster Pump: Fountain Pumps: Fountains: Electrical Electrical run Approx. 25 linear feet With 1" PVC conduit , & (4) #8 copper THWN Wires to GFCI Protected Pool Equipment (2) - pool 24 watt lights With 100' cords / (1) - 12 Watt Spa Light With 100' Cord J-box to be located within 50' of pool/spa lights L.V. lights use 1 1/2" PVC pipe a min. of 12" to a 1" conduit running to the J- box No bonding wire, wet niche or grounding wire required for ( L.V. lights ) Minimum of 30" working clearance at the pool sub panel board Standard 50 amp panel with overcurrent protective device (circuit breaker) at least equal to or greater than the circuit voltage One outlet at equipment, all outlets to be GFCI protected, Tamper Resistant, Weather Resistant, and provided with an “in-use” type cover. 14 volts to LED transformer for low voltage lights, supply & install 300 watt transformer & Label breakers when applicable Minimum of 30" working clearance at the pool sub panel board Plumbing Use sweep elbows 10" minimum prior to pump Pool equipment shall be anchored to concrete pad Gas Line runs to Pool Equipment PVC pipes should be painted to protect them from ultraviolet rays Heater shall be 4' from an opening window "Shade" plumbing trenches after inspection if rocky soil is present A gas shut-off valve is required outside of, and within 3 feet of the heater Skimmer and auto fill with clear "pour a lids" Verify skimmer location for common wind flows direction, not in any raised areas Stub plumbing for solar heating with valves- (see homeowner) A length of plumbing ( 36" min.) between the filter and the heater to allow for future solar heating 2.5" suction and 2" return lines min. for pool with directional inlets that adequately mix the pool water See H.O. for separate suction line and valve for pool cleaner in zero elevation . Plaster /start-up to install pool sweep safety cover All gas lines under slabs, and/or foundations, shall be sleeved per the 2018 UPC section 1210.1.6 Gas line installed underground under roof structure shall be installed as per ( CPC 1210.16). Hose bib to comply with ISPC 306.9.1 Water supply must be protected from backflow ISPC 302.5. Salt system- See homeowner Notes Final equipment location per homeowner to meet local codes 3.Pool area to be fenced and alarms per local ordinance gates to be self closing and self latching , gate latch to be min. of 54" above grade per local codes. SWIMMING POOLS AND SPAS SHALL HAVE: At least two circulation suction outlets per pump and separated at least 3' apart, and covered with anti- entrapment grates conforming to ASNI/APSP-16 standard Filtration flow rate Pool Volume =( gpm) OR, 36 gpm, whichever is Greater No construction within any easements. MUST MAINTAIN EXISTING DRAINAGE: TO DRAIN AWAY FROM HOUSE AND POOL CONTRACTORS SHALL PROVIDE, IMPLEMENT AND MAINTAIN EROSION AND SEDIMENT CONTROL MEASURES DURING CONSTRUCTION 360 NotesSee homeowner- For exact equipment location prior to plumbing Pool equipment shall not block the only access to mechanical equipment 4.Prior to start of every phase of construction verify with homeowner materials, locations, and options Soil report or additional engineering that may be required - By H.O. BMP/Storm Management Plan Prepared Required - By H.O. Tractor Access- See homeowner, rebuild walls and replace fence & reverse gates to meet local codes Variable speed pump operates at below 50 decibels All elevations are approximate. Verify heights and elevations prior to building See local codes for possible P-Trap See homeowner for colors and materials prior to start Outdoor pools/spas equipped with gas or electric heater shall also be equipped with a pool/spa cover. The cover should be fitted and installed during the final inspection Outdoor lighting: All luminaries mounted to the building or to other building or to other buildings on the same lot shall be high efficacy luminaries or must be controlled by a motion senor And controlled by one of these: Photocontrol or Astronomical time clock or Energy management control system (EMCS) A time switch or similar control mechanism shall be installed as part of a pool water circulation control system that will allow all pumps to be set or programmed to run only during the off-peak electric demand period and for the minimum time necessary to maintain the water in the condition required by applicable public health standard All metal within 5' of water edge must be bonded 1. This is a conceptual construction drawing does not detail all construction items. The property owner and/or contractor shall determine all final dimensions and construction details. Homeowner or contractors are responsible for all necessary building permits. 3. In field adjustments may be required verify any changes with homeowner 2. This is not a surveyed plan and only shows dimensions given by homeowner. Property measurements should be confirmed with a licensed land surveyor if required. Safety 1. Exit alarms on the private single family home's doors that provide direct access to the swimming pool or spa 2. An alarm that, when placed in the pool or spa will sound off if it detects an unauthorized or accidental entrance to the water Swimming pool heating as per 2019 residential compliance manual sec. 5.7 swimming pool and spa heating . Any new or replacement gas or electric swimming pool heater system in a residential occupancy shall be equipped with all of the following: . An On-Off switch mounted on the outside of the heater for easy access . A permanent weatherproof plate or card, easily readable, giving instruction for the efficient operation of the swimming pool. . Pool and spa heaters may not have continuously burning pilot lights. Contractors shall meet or exceed all local codes and engineering .2022 California building code volumes 1&2 . 2022 California Mechanical Code . 2022 California Electrical Code . 2022 California Existing Buildings Codes . 2022 California Fire Codes . 2022 California Energy Codes . 2022 California Residential Building Codes . 2022 California Green Building Standards Code . 2022 California Historical Building Code Pool Guard Model PGRM-2 Pool Alarms per code NSF certified to the ASTM safety specification F2208 (1) for pool, (1) for spa. Pool equipment to be GFCI protected. 1" Schedule 40 electrical conduit w/ (4) #8 AWG THWN Copper wires 18" deep min., 50 AMP sub panel @ equipment on a 40 AMP GFCI Breaker. 1 1 2" poly gas line w/ 12 gauge yellow tracer wire to 3 4" stub @ equipment 18" deep min. (e) 6' high access gate shall open outwards away from the pool and shall be self-closing and have a self-latching device. Techko model S189A door alarm per code UL 2017 at all doors that lead to the pool. #8 bond wire to be connected at 4 points of the pool waterline. . 2022 California Plumbing Building Code REVISIONS BY If any ERRORS, DISCREPANCIES or OMISSIONS appear in the drawings, specifications or other contract documents, the GENERAL CONTRACTOR shall notify the Designer in writing of such error or omission. In the event that the GENERAL CONTRACTOR fails to give such notice before construction and/ or fabrication of the work, THE GENERAL CONTRACTOR WILL BE HELD RESPONSIBLE to the result of any errors, discrepancies or omissions and the cost of rectifying the same. JOSUE MUNOZ C H E C K E D D R A W N D A T E SCALE: 1/8"=1' A-1 SITE PLAN DRAFTER: JOSUE MUNOZ 442-471-7317 PLANCOREINFO@GMAIL.COM 85085 CALLE FELIZ COACHELLA CA 92236 8/19/25 44 5 8 5 M A R G U E R I T E C T LA Q U I N T A C A 9 2 2 5 3 MARQUIS / RE-PLASTER TO EXISTING POOL & SPA ALONG WITH NEW POOL EQUPMENT TO REPLACE EXISTING AT REAR YARD. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED AS NOT A PART OF. APPROVED SITE PLAN REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. 09/03/2025Taylor Tuvell BPOL2025-0165