Loading...
HomeMy WebLinkAboutBSOL2024-0127DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address APN: Legal Description Property Zoning: Valuation: BUILDING PERMIT eca Qa�&a CALIFORNIA Solar BSOL2024-0127 81910 FIORI DEL DESERTO DR 764470007 Lot 13 MB 373/59 TR 30092 RL, 13 $15, 000.00 Owner: Applicant: PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 04/22/2024 ISSUED DATE: 05/01/2024 Richmond American Homes Ivan Garcia 775 FIERO LANE SUITE 200, SAN LUIS OBISPO, CA 93401 Contractor: Ivan Garcia / 750184 775 FIERO LANE SUITE 200, SAN LUIS OBISPO, CA 93401 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 5/1/24 11:57 pm Page 1 of 4 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2024-0127 Property Address: 81910 FIORI DEL DESERTO DR construction lender preliminary notice from that duty. Printed: 5/1/24 11:57 pm Page 2 of 4 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2024-0127 Property Address: 81910 FIORI DEL DESERTO DR PLAN 2 (S853): 5.925 kW SOLAR ARRAY - (15) JA SOLAR-JAM54S31-395/MR - (15) ENPHASE: IQ7PLUS-72-2-US / LOT 13 / REFERENCE BCPR2022-0005 / 2019 CALIFORNIA BUILDING CODES PV System Type Residential System Size (kW DC) 5.925 PV Strings (EA) 2 PV Miscellaneous 0 Zoning RL General Plan LDR Equipment EA City Limits Within La Quinta Limits Subdivision Name TR 30092 Lot Number 13 Lot Size 1621.05 Centerlines 92519 Legal Description Lot 13 MB 373/59 TR 30092 Type Group Sq Ft Value Invoice No. Fee INV-00006284 Digital Archiving and Records Management Fee - OTC Technology Enhancement Fee Permit Issuance Solar (PV) Less than 10kW PC Credit Card Convenience Fee Building Standards Administration Solar (PV) Less than 10kW Total for InvoiceINV-00006284 Grand Total for Permit Fee Amount $12.00 $8.00 $115.94 $30.51 $4.95 $1.00 $30.51 $202.91 $202.91 Amount Paid $12.00 $8.00 $115.94 $30.51 $4.95 $1.00 $30.51 $202.91 $202.91 Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 04/23/2024 8:14 04/23/2024 8:14 ---------------------------------------------------------------------------------------------------------------------------------------- Submittal Document Verification v.1 Generic Action 04/23/2024 8:14 Plan Check v.1 04/23/2024 0:00 04/24/2024 9:06 ------------------------------------------------------------ Building Review (1 Day) v.1 Receive Submittal 04/23/2024 0:00 04/24/2024 9:07 Permit Issuance v.1 05/01/2024 8:22 05/01/2024 16:57 ---------------------------------------------------------------------------------------------------------------------------------------- Verify Contractor info & Conditions have been met v.1 Generic Action 05/01/2024 8:22 ---------------------------------------------------- Verify & Invoice Fees v.1 Generic Action 05/01/2024 8:22 ---------------------------------------------------------------------------------------------------------------------------------------- Verify Fee Payment & Issue Permit v.1 Generic Action 05/01/2024 16:57 ---------------------------------------------------------------------------------------------------------------------------------------- Print, Attach, and Email Building Permit v.1 Create Report 05/01/2024 16:57 05/01/2024 16:57 Solar Inspections v.1 ---------------------------------------------------------------------------------------------------------------------------------------- Rough Electrical v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 ---------------------------------------------------------------------------------------------------------------------------------------- Solar Final v.1 Inspection Printed: 5/1/24 11:57 pm Page 3 of 4 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2024-0127 Property Address: 81910 FIORI DEL DESERTO DR Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the buildinq official. Printed: 5/1/24 11:57 pm Page 4 of 4 AZI MODS 180' 0 270' 15 90, 0 0° 0 BELLA AT PIAZZA SERENA TRACT: PHASE: 12 LOT: 13 ADDRESS: • 81-910 FIORI DEL DESERTO DRIVE LA QUINTA CA 92253 HOME CONFIGURATION: • PLAN:S853 • ELEV: C QVQTf=RA c17f=- 0 5.925 kW DC, 4.35 kW AC MODULES: • (15) JA SOLAR: JAM54S31-395/MR INVERTER(S): • (15) ENPHASE: IQ7PLUS-72-2-US CTnDAf_C- RACKING: ULTRA RAIL, OMNIBASE WITH STANDOFF TO RAFTER: SNR-DC-01249 • Max Spacing (Landscape): 48", Staggered • Max Spacing (Portrait): 48", Staggered • Max Overhang: L/3 ARRAY DETAILS: • ROOF TYPE: TILE • ARRAYSLOPES: 4/12(18°) • TOTAL PV ARRAY AREA: 315 SQFT. • TOTAL ROOF SURFACE AREA: 2222 SQFT. • PERCENTAGE PV COVERAGE: 14% CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 04/24/2024 Bl C 20'-3" 28'-5" BSOL2024-0127 - 81910 FIORI DEL DESERTO PLAN 2 (S853): 5.925 kW SOLAR ARRAY - (15) JA SOLAR-JAM54S31-395/MR - (15) ENPHASE: IQ7PLUS-72-2-US / LOT 13 / REFERENCE BCPR2022-0005 / 2019 CALIFORNIA BUILDING CODES 81-910 FIORI DEL DESERTO DRIVE LEGEND F-M I MAIN PANEL Q AC DISCONNECT PC IQ COMBINER BOX EPV MODULES FIRE SETBACKS sunrun GILBERT CORREIA, C10, C46 CA CL #750184 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 DEVELOPER: RICHMOND AMERICAN HOMES (RIVERSIDE) DEVELOPMENT: BELLA AT PIAZZA SERENA HOME ADDRESS: 81-910 FIORI DEL DESERTO DRIVE LA QUINTA CA 92253 AHJ: CA -CITY LA QUINTA IDESIGNER: I ALEX BRADSHAW SHEET SITE LAYOUT REV: A 4/2/2024 1 PAGE PV-2.0 SITE PLAN - SCALE = 1/8" = 1'-0" Point of Interconnection, Load Side 705.12(B)(2)(1)(b) Existing 240V/200A MIN. Service Panel, Single Phase, with 200A Main Disconnect 20A 15A Microinverter: Enphase z _ 20A M IQ7PLUS-72-2-US D (Mounted to the back of each module) 0 n PV Circuit 1: = Oc Square D DU221RB, 200A 8 JA SOLAR 1 2 8 m 240V/30A, Unfused, JAM54S31-395/MR 1 NEMA3R PV Modules / Parallel u u 2 2 3 3 3 PV Circuit 2: 1 2 7 25A 7 JA' 1 ON ROOF Combiner Panel Enphase IQ Combiner X-IQ- JAM54S31 395/MR AM1-240-3 64A/240V Continuous, protection PV Modules / Parallel �� _ 2 I x max 80A breaker on solar output; with 10 KAIC 2 I IN I 1 NEMA 3R Junction Box circuit breakers Visibl e/Lockable 'Knife' = FACILINGRoUNo AC Disconnect Builder to Ensure SPD Compliance (230.67) Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper) TAG CONDUCTOR NEUTRAL GROUND CONDUIT 1 (2) 12 AWG PV WIRE NONE (1) 6 AWG BARE COPPER NONE 2 (2) 10 AWG NM NONE (1) 10 AWG NM 3/4" NM-B sunrun 3 (2) 10 AWG NM (1) 10 AWG NM (1) 8 AWG NM 3/4" NM-B OR Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper) GILBERT CORREIA, C10, C46 CA CL #750184 TAG CONDUCTOR NEUTRAL GROUND CONDUIT 1 (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER NONE PHO RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 2 (2) 10 AWG THHN-THWN-2 NONE (1) 10 AWG THHN/THWN-2 3/4" EMT OR EQUIVALENT FAX 949.215.7778 3 (2) 10 AWG THHN-THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 3/4" EMT OR EQUIVALENT DEVELOPER: RICHMOND AMERICAN HOMES *DEPENDING ON INVENTORY AT TIME OF INSTALL* (RIVERSIDE) DEVELOPMENT: BELLA AT PIAZZA SERENA MODULE CHARACTERISTICS JA SOLAR: JAM54S31-395/MR: 395 W HOME ADDRESS: OPEN CIRCUIT VOLTAGE: 36.98 V 81-910 FIORI DEL DESERTO DRIVE MAX POWER VOLTAGE: 30.84 V LA QUINTA CA 92253 SHORT CIRCUIT CURRENT: 13.7 A BSOL2024-0127 AHJ: CA -CITY LA QUINTA CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 04/24/2024 8Y / C IDESIGNER: I ALEX BRADSHAW SHEET ELECTRICAL REV: A 4/2/2024 PAGE PV-4.0 CAUTION MULTIPLE SOURCES OF POWER WITH DISCONNECTS LOCATED AS SHOWN SOLAR PANELS AND MICRO INVERTERS ON ROOF COMBINER PANEL MAIN PANEL & AC DISCONNECT 81-910 FIORI DEL DESERTO DRIVE LA QUINTA CA 92253 :16Yo]y��YZd�Sf�x7 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 04/24/2024 Fn D c LABELING FORMAT RICHMOND AMERICAN HOMES (RIVERSIDE) BELLA AT PIAZZA SERENA 81-910 FIORI DEL DESERTO DRIVE LA QUINTA CA 92253 LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE.