HomeMy WebLinkAboutBRES2021-0122BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Building Residential
Permit Number:
BRES2021-0122
Property Address:
54621 SOUTHERN HILLS
APN:
775101065
Legal Description
Property Zoning:
Valuation:
$26,500.00
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 03/10/2021
ISSUED DATE: 03/11/2021
CALIFORNIA
Owner: Ed Chibri
54621 Southern Hills, La Quinta, CA 92253
Applicant: Nicole Tamez
75100 St Charles Place, Palm Desert, CA 92211
Contractor: Timothy Ellenz / 906636
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 4/30/26 2:10 pm Page 1 of 3
BUILDING PERMIT
Permit Type: Building Residential
Permit Number: BRES2021-0122
Property Address: 54621 SOUTHERN HILLS
CHIBRI / [111 WINDOWS [7]PATIO DOORS CHANGE OUTS ... REPLACE [111 WINDOWS AND [71 PATIO DOORS THROUGHOUT
DWELLING DWELLING. THIS PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO EXISTING PENETRATIONS. 2019 CALIFORNIA
BUILDING CODES
�nstructinn Deta
Residential Work Type Remodel Conditioned Square 0 Grading Required? No
Footage
Number of 18 Number of Flag or 0 New Electrical Square 0
Door/Window Light Pole(s)? Footage
Retrofit/Repair
Type Group Sq Ft Value
Invoice No. Fee
Fee Amount
Amount Paid
PERM IT-BRES2021-012 RECORDS MANAGEMENT FEE - MAJOR
$21.00
$21.00
2 TECHNOLOGY ENHANCEMENT FEE
$5.00
$5.00
DOOR/WINDOW, RETRO/REPAIR, EA ADDITION 5
$33.81
$33.81
DOOR/WINDOW, RETRO/REPAIR, FIRST 7
$67.62
$67.62
DOOR/WINDOW, RETRO/REPAIR, FIRST 7 PC
$66.01
$66.01
Total for Invoice PERMIT-BRES2021-0122
$193.44
$193.44
Grand Total for Permit
$193.44
$193.44
Workflow Step / Action Name
Action Type Start Date End Date
Inspections v.1 03/10/2021 0:00
-
---------------------------------------------------------------------------------------------------------------------------------------
FINAL'* v.1 Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Printed: 4/30/26 2:10 pm Page 2 of 3
BUILDING PERMIT
Permit Type: Building Residential
Permit Number: BRES2021-0122
Property Address: 54621 SOUTHERN HILLS
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
iurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the buildina official.
Printed: 4/30/26 2:10 pm Page 3 of 3
� ' .... `. -------- ._ —_ 1 CI -)
f
BRES2021-0122 / 54621 SOUTHERN HILLS
CITY OF LAQUINTA
BUILDING DIVISION° }'
REVIEWED FOR 1-5
CODE
COMPLIANCE
DATE 3/11 /2021 BY Ain
REPLACE [111 WINDOWS AND [71 PATIO
DOORS THROUGHOUT DWELLING W
DWELLING. THIS PERMIT DOES NOT ---
INCLUDE ANY ALTERATIONS TO I
EXISTING PENETRATIONS. 2019 _
CALIFORNIA BUILDING CODES."
Is
hI �
's
i
i
9'
i
ii
i
I
All construction shall comply with the 2019 California Residential,
Mechanical, Electrical, Plumbing, Green Building and Energy Codes and
the La Quinta Municipal Code.
CALIFORNIA WINDOW and DOOR
75-091 ST. CHARLES PLACE UNIT G
PALM DESERT, CA 92211-9056
760 773 1053
561/40
21 1W _,.)
Project Name:
Contact Name:
Contact Phone:
Contact E-Mail:
Builder / GC:
Project Address:
Viewed from Exterior (Net Frame) - Image scaled 3/4" =1' 0"
MASTER
Line No:
i
Locatlon Label:
I MasBed(2)
QuaW :
2
Product Line:
Standard_Aluminum
Model:
Pidure
Sire:
Net Frame: 211/2"x 56 1/4"
Finishes:
EA Bronze Anodised/ Int Bronze Anodised
Fin Type:
Standard Z-Bar
Glass:
1/B" SunCaarMA%(Low-E) over 11V Clear wah Gray
EdgeGWMMS acer
U-Factor / SHGC / V r:
.36 / 161.59
Ratings:
SM No flaring, 01TC: No Ratln& PG: M35
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0= Obscure quote Number: SOP01005057_I
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E= Meets Egress per IBC (international Building Code) for above grade application.
Validate against local codes. Page: 1of 13
CALIFORNIA WINDOW and DOOR Project Name:
Contact Name:
75-091 ST. CHARLES PLACE UNIT G Contact Phone:
E-4
����PALM DESERT? CA 92211-9056 Contact E-Mail:
",e 'w°°°"7607731053 Builder/GC: 99 n
Project Address: �j �>/ipi &„�°
11631490
Viewed from Exterior (Net Frame) -Image scaled 2/2" =1' 0"
MASTER BEDROOM
Lane No:
2
Location/Label:
MasBed
Quantity
_.._.
I
Pmded line:
_
Standard Aluminum
Model:
sliding Door Two Panel
Sloe_
Net Frame: 1163/4"x 78 Ile
Finishes:
EA Brame Anodized/ let Bronze Anodized
Fin Type:
StandaM Z-Bar
Glass:
3/16" SunCoatMM (Low-E) Tempered over 3/16" Clear
Tempered with Gray EdgeGardMMS acer
Screen:
Upgraded with Fiberglass Mesh, Screen Ship loose
U-Factor I SHGC/W.
A7/.24/.M
Clear Opening:
W543/36'x H 753/4"S.Ft. 28.5
Ratings:
6TC:3o, DITC: 26, PG; No Red,
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = Obscure Quote Number: SQP01005057_I
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E= Meets Egress per IBC (international Building Code) for above grade application.
Validate against local codes. Page; 2 of 23
it
■
ENTRY
CALIFORNIA WINDOW and DOOR
75-091 ST. CHARLES PLACE UNIT G
PALM DESERT, CA 92211-9056
760 7731053
561/4"
Project Name:
Contact Name:
Contact Phone:
Contact E-Mail:
Builder / GC:
Project Address:
h--_ 331/Y - �
Viewed from Exterior (Net Frame) - Image scaled 3/4' =1' 0"
cxA.
Line No
3
Location/Labe1:
Ha11(3)
__------Guanft:
3
Produd ❑ne:
Standard Aluminum
Model:
Picture "
Size:
Net name: 331/21'x561/4"
finishes:
Ext Bronze Modized/ Int Bronze Anodized
nnType:
standard Z-Bar
Giass:
1/8" $unCoatMM (to.-E) over 1/8' Clear with Gray
Ed,G.WMM spacer
U-Fodor / SHGC / V r:
.36 / A6 / .59
Ratin :
STC No Rating, OITC: No Radn PG CW35
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = Obscure Quote Number: SQP01005057_I
Email: adessa@californiawindowanddoor.net T= Tempered Last Modifled Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 3 of 13
CALIFORNIA WINDOW and DOOR Protect Name:
1 Contact Name:
75-091 ST. CHARLES PLACE UNIT G Contact Phone: 0
il
PALM DESERT, CA 92211-9056 Contact E-Mail:
o0dLY1 760 773 1053 Builder/ GC: ter/
Project Address:
781/4°°
ME
E T T
48 3/4K __
931/2`' _
Viewed from Exterior (Net Frame) - Image scaled 1/2" =1' 0"
Line No:
4
Location abet:
aetl
4ualrory:
_
i
Product Line:
_
Standard Aluminum
Model:
Slidin Doom mPanel
_
Size:
Net frame: 931/2"x 781/411
Finishes:
EA Bronze Anodized/ Int Bronze Anodized
Fin Ty e:
Standard Z-Bar
Glass:
5/32"SunCeatMAX u.a -Q Tempered over 5132" Clear
Tem eyed wBb Gray Ed,GaNMAX Spacer
Screen:
Upgraded with Ma lass Mesh, Screen Ship Loose
V-Factor / SHGC / V is
.4) /.24 / .54
Clear Opening:
W429/16"XH)53/4"Sa.F622.39
Ratings:
STC: 3G, OITC 26, PG: a2G
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0= Obscure quote Number: SCIP01005057_1
Email: adessa@californiawindowanddoor.net T= Tempered ____ ]Last Modified Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 4 of 13
CALIFORNIA WINDOW and DOOR Project Name: lee.
Contact Name:
75-091 ST. CHARLES PLACE UNIT G Contact Phone:
PALM DESERT, CA 92211-9056 Contact E-Mail:
Builder/GQ
7607731053 /Jn q
Project Address: (�c�LG�'If4n 4�'
Viewed from Exterior (Net Frame) - Image scaled 1/2" =1' 0"
BREAKFAST
Line No:
5
Location/Label:
Nook
__.._... Quantity:
1 .__..
Product Line:
Standard Aluminum
Model:
Picture
Size:
Net Frame: 901/2"x56"
FlnBhes:
Est Bronze Anodized/ Int Bronze Anodized
FhT e:
Standard Z-Bar
Glass:
3/16" sunCoatMAX (low-E) oyer 31W Clear with Gray Cardinal
Boa Spacer
U-Factor / SNGC / V r:
.38 / .361.58
Ratings:
STC: No Raen&01TC: No Roch PG: No Rating
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0= Obscure Quote Number: SQP01005057_1
Email: adessa@californiawlndowanddoor.net T= Tempered Last Modified Date: 2/24/2021 L47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 5 of 13
CALIFORNIA WINDOW and DOOR
Protect Name:
Contact Name:
75-091 ST. CHARLES PLACE UNIT G
Contact Phone:
® A
PALM DESERT, CA 92211-9056
Contact E-Mail:
7607731053
Builder/GC:
Project Address:
78 Ile
E T T
34 3/4"
u 69117
Viewed from Exterior (Net Frame) - Image scaled 112" =1' 0"
NOOK
_ Lee No:
6
Wcatlon/Label:
Nook
Quantity:
1
Pmdu_a Line:
Standard Aluminum
_
Model;
_-
ing Panel
_
Sire:
NatFrmoorTwo
Nei Frame: 691/2"x]81(4"
Finishes:
Eat Bmnze Anodized/ Int Bronze Anodized
Fin Type:
Standard Z-Bar
61aec
118"SmCOatMA%(Wap-E) Tempered over 1/8"Clear Tempered
With Gray EdgeGardMMSlater
Screen:
Upgraded Well Fiberglass Mesh, screen Ship Loose
U-Factor/ SHGC/ VT:
.47/.241.55
Clear Opening:
W309/16"x HZ53/4"Sa. Ft. 16.08
Ratings:
STC 27, ORC: 2Z, PG: no
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = Obscure Quote Number: SQP01005057_I
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E= Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 6 of 13
CALIFORNIA WINDOW and DOOR
Protect Name:
Contact Name:
J
75-091 ST. CHARLES PLACE UNIT G
Contact Phone:
PALM DESERT, CA 92211-9056
Contact E-Mail:
7607733053
Builder/eC:
Project Address:
41 114M �►
18"� h 18'
(o+0.0 (o+ow
7811r
Viewed from Exterior (Net Frame) - Image scaled 1/2" =1' 0"
BAR
Line No:
7
Location/Label:
Kit
OuaMIN:
1
Pradua Line:
_
Standard Aluminum
Model:
Double Vent
Site:
Net Frame: 781/2"x413/4"
Oimenslons:
Sash Width: 18"
Finishes:
BM Bronze Anodized/ Int Bronze Anodized
Fin Type:
Standard Z-Bar
Glass:
1/8" SunCoatMM (Low-E) over 1/8" tlear Wth Gay
Bt.ndardMAX9
Screen:
standard with Fiberglass Mesh
Fiberglass
U-Factar/SMGC/Vr:
.4]/.24/.55
ClearOpening:
W157/8"xH391/4"Sq. F[A.33
Ratings: I
STC 29, OITC: 25, PG: R20
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = Obscure Quote Number: SQPOIUDS057 I
Email: adessa@californiawindowanddoor.net T= Tempered Last Modif led Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 7 of 13
CALIFORNIA WINDOW and DOOR Protect Name:
Contact Name:
75-091 ST. CHARLES PLACE UNIT G Contact Phone: 0
it
PALM DESERT, CA 92211-9056 Contact E-Mail:
°°°"7607731OS3 Builder/GC:
Project Address: / �jno.�,n�. ;�ry, &,r`
621/4`°
4811PT
Viewed from Exterior (Net Frame) - Image scaled 3/4" =1' 0"
BAR
Line No:
8
W.tion/iebel:
Be,
Quantity:
_
1
Prod.a Line:
Standard AW mini.
Model:
Picture --_--
Size:
Net Frame: 48112"x 6Z 1/4"
Finishes:
Eat Bronze Anodized/ Int Bronze Anodhad
Fin T a
Standard Z.8ar
Glans:
1/8' 5unCeatMA% u.o El wer 11V Clear with Gray
Etl eGardMAx Spamr
Q-FaRWr/SHGC/ W:
.R5/.26/.59
Ratings:
STC: No Rating, OITC NO Rating, PG: CW35
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: O = Obscure Quote Number: SQP01005057_I
Email: adessa@californlawlndowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 8 of 13
.gas
BAR OPTION
621W
CALIFORNIA WINDOW and DOOR
75-091 ST. CHARLES PLACE UNIT G
PALM DESERT, CA 92211-9056
760 7731053
27114'
64112'
Viewed from Exterior (Net Frame) - Image scaled 1/2" -1' 0"
Project Name:
Contact Name:
Contact Phone:
Contact E-Mail:
Builder / GC:
Project Address:
Line No:
9
Lwatlon/label:
Bar
Quantity:
1
ProduR Une:
Standard Aluminum
Model:
Half Vent
Siee'
Net Frame: 541/2"x 621/4"
Finishes:
EA Bronee Anodimd/ Int Bronze Anodized
Fin Type:
Standard 2-aar
Glans:
1/8"SmCoatMAR ILow-E) over 11W Cleer with Gray
EdgeGardMAHSp .
Screen:
Standard with Fiberglass Mesh
U-Factor/SHGC/Vr:
A7/.24/.55
Clear Opening:
I W253/8"x H601/4"SA. FA 10.62
Badngs:
I STC 29, GITC: 25, PG: R20
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = obscure Quote Number: SQPOI005o57_3
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (international Building Code) for above grade application.
Validate against local codes. Page• 9 of 13
CALIFORNIA WINDOW and DOOR
Project Name:
Contact Name:
75-091 ST. CHARLES PLACE UNIT G
Contact Phone:
PALM 2
DESERT, CA 92211-9056
Contact E-Mail:
0.
76
Builder/GC:
Project Address:
�Ov n1�. ��.y &.rr
841/2"
T
a.w{
Viewed from Exterior (Net Frame) - Image scaled 1/2" = V 0"
DINING
❑ne N,e
10
Location/Label:
Atrium(2)
Quantity:
2
Product Line:
standard Aluminum
Model:
Picture
Size:
_
Net Frame: 133/4"x a41/2"
Finishes:
EA Branze Anodized/ Int Bronze Anodized
Fin Type:
Standard Z-Bar
Glass:
5132" sunCoatMAX (taw-E) Tempered aver 5/32" Clear
Tempered with Gray EdgeGardMM Spacer
U-Factor/SHGC/W:
.36/.26/.59
Raangs:
STC: No Rating, OITC: No Rating, PG: Cw35
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0= Obscure Quote Number: SQPOIOOSO57_I
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 10 of 13
CALIFORNIA WINDOW and DOOR
Project Name:yy
Contact Name:
75.091 ST. CHARLES PLACE UNIT G
Contact Phone:
® O
PALM DESERT, CA 92211-9056
Contact E-Mail:
7607731053
Builder/GC:
Project Address:
LV 39" .
57 I1r
Viewed from Exterior (Net frame) - Image scaled 3/8" =1' 0"
ATRIUM DINING
Line No:
11
W=lon/label:
Atrium
quantity:
1
Product Line:
Standard Aluminum
Model:
sliding Wars oPanel
Size:
Net frame: 571/2"x 941/4"
finishes:
Ed Bronze Anodized/Im Bronze Anoda d
FlaT a
Standard Saar
Glass:
5/32" SunCaatMAX ILow-E) Tempered over 5/32" Clear
Tempered oath Gray EdgeGard" Spacer
Screen:
Upgraded with Flerlaae Mesh, Screen Ship Loose
U,Pactar / SN GC / V r:
.47 /.24 / .54
ClearOening:
W]q 9/16"eH913/4"Sq.ft15.65
Ratings:
I STC: 30, GITC: 26, PG: 120
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = Obscure quote Number: SQP01005057_S
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E= Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. I Page: 11 of 23
�■ to■R
■
941/40
CALIFORNIA WINDOW and DOOR
75-091 ST. CHARLES PLACE UNIT G
PALM DESERT, CA 92211-9056
760 7731053
Project Name:
Contact Name:
Contact Phone:
Contact E-Mail:
Builder/GC:
Project Address:
T
E T
,03140
81 11r
Viewed from Exterior (Net Frame) - Image scaled 3/8" =1' 0"
ATRIUM BEDROOM
Une No;
12
Location/label:
I Atrium
Quantity:
1
product Line:
standard Aluminum
Model:
Sliding Dear Two Panel
Slee:
Net Frame: $11/2" x 94 1/4"
Finishes:
Ed Bronze Anodized Int Bronze Anodized
Fln Type:
standard 2-Bar
Glass:
5/32" 5unCpcMA£ (LOW-E) Tempered over 5/32" Clear
Tempered with Gray EdgeGardMAXSpacer
Screen:
Upgraded with Fiberglass Mesh, Screen Ship Loose
U-Factor/SHGC/ W:
.47/14/.54
Clear Opening:
W369/16" x H 91314, sq. R. 213
Ratin
STC: 30, OITC: 26, PG: R30
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: 0 = Obscure quote Number: SQP01005057_1
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. Page: 12 of 13
CALIFORNIA WINDOW and DOOR Project Name:
Contact Name:
N 75-091 ST. CHARLES PLACE UNIT G Contact Phone:
0 IN
PALM DESERT, CA 92211-9056 Contact E-Mail:
760 7731053 Builder :
Project Address:
essss: �j'xA� &,It`
941/4'
T E T
46 We .�
9311r
Viewed from Exterior (Net Frame) - Image scaled 3/8" =1' 0"
ATRIUM BEDROOM
Line No:
13
Location/label:
Atrium
Quantity:
_
1
Produd Line:
_
Standard Aluminum
Model:
Sliding Ooar Two Panel
Size:
Net Frame: 931/2"x931/4"
Finishes:
WBmnze Anodized/ Int Bronze Anodlzed
Fin Type:
Standard Z-Bar
Glass:
5132" SunCm tMAX (Low-E) Tempered wer 5/32" Clear
Tem emal with Gray EdgeGardMAXSparer
Screem
Upgraded with Fiberglass Mesh,&men Ship Lome
U-Fattor/SHGC/Vi:
.47/42.34/.54
Clear Opening:
W9/16°x H913/4"Sq. FA 2Z12
Ratings:
I STQ 30, ORC 26, PG: R20
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: O = Obscure
Quote Number: SgP01005057_S
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/24/20211:47 PM
Phone: E = Meets Egress per IBC (international Building Code) for above grade application.
Validate against local codes. page..
13 of 13
Project Name:
CALIFORNIA WINDOW and DOOR Contact Name:
75-091 ST. CHARLES PLACE UNIT G Contact Phone:
PALM DESERT, CA 92211-9056 Contact E-Mall:
7607731053 Builder/GC: Project Address:
Li
41"-�- 41"� 411
164"
Viewed from Exterior (Net Frame) - Image scaled 1/4" =1' 0"
FAMILY
Line No:
1
Loudlon/label:
Liv _ -
quanti :
1-
Pmdud Line:
Aluminum
Model:
_standard _
Sliding Door Four Panel
Sim:
Net Frame: 1GV x 941/4"
Finishes:
EMBmme Anodized/ Int Bmnxe Anodized
Finivpe:
Standard Z-Bar
Glass:
5/32"SimC..VAM(Wo -E) Tempered over 5/32"Clear
Tempered w th Gray EdgeGardMAx Spacer
Screen:
U raded with Fiberglass Mesh, Screen Ship Loose
U-Factor / SHGC i V r:
.41 /.24) .54
Clear Opening:
W>45/8"xH913/4"9q. ft. 47.55
Ratings:
STC: 30, CITC: 26, PG: Ran
Customer Approval:
Sales Rep: Name: Adessa Perez Legend: O = Obscure quote Number: SQP0'005441 1
Email: adessa@californiawindowanddoor.net T= Tempered Last Modified Date: 2/Z4/20211:47 PM
Phone: E= Meets Egress per IBC (International Building Code) for above grade application.
Validate against local codes. page: 1 of 1
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
CHIBRI RESIDENCE's alteration
54621 SOUTHERN HILLS
LA QUINTA, CA 92253
Project Designer:
MR. CHIBRI
54621 SOUTHERN HILLS
LA QUINTA, CA 92253
Report Prepared by:
TITLE 24 OF THE DESERT SERVICES INC.
title24ofthedesert@gmaii.com
760 278.1840,
Job Number:
21 - CWMT - 005
Date:
3/10/2021
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software— www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
2
3
13
14
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CF1R-PRF-OlE
(Page 1 of 10)
GENERAL INFORMATION
01
Project Name
CHIBRI RESIDENCE
02
Run Title
Title 24 Analysis
03
Project Location
54621 SOUTHERN HILLS
04
City
LA QUINTA
05
Standards Version
2019
06
Zip code
92253
07
Software Version
EnergyPro 8.2
08
Climate Zone
15
09
Front Orientation (deg/ Cardinal)
270
10
Building Type
Single family
11
Number of Dwelling Units
1
12
Project Scope
AdditionAlteration
13
Number of Bedrooms
3
14
Addition Cord. Floor Area (it')
0
15
Number of Stories
1
16
Existing Cord. Floor Area (it')
2846
17
Fenestration Average U-factor
0.44
18
Total Cond. Floor Area (ftz)
2846
19
Glazing Percentage (%)
22.90%
20
ADU Bedroom Count
n/a
21
ADU Conditioned Floor Area
n/a
22
Is Natural Gas Available?
Yes
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
Building does not require field testing or HERS verification
03
IThis building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
7.09
9.94
-2.85
-40.2
Space Cooling
307.42
280.82
26.6
8.7
IAQ Ventilation
0
0
0
Water Heating
11.68
11.68
0
0
Self Utilization/Flexibility Credit
n/a
0
0
n/a
Compliance Energy Total
326.19
302.44
23.75
7.3
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-1OT00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Window overhangs and/or fins
FEATURE SUMMARY
CF1R-PRF-01E
(Page 2 of 10)
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the bulling tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• --None--
Cooling System Verifications:
• --None--
Heating System Verifications:
• --None--
HVAC Distribution System Verifications:
• --None--
Domestic Hot Water System Verifications:
• --None--
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (k2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
CHIBRI RESIDENCE
2846
1
3
1
0
1
ZONE INFORMATION
O1
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft2)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
A
Conditioned
(E) HAVC1
2846
10.5
DHW Sys 1
N/A
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards- 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CF1R-PRF-01E
(Page 3 of 10)
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
2
Gross Area (ft )
Window and
Door Area (ft2)
Tilt (deg)
Wall Exceptions
Status
Verified Existing
Condition
N-1245
A
Def Wall'78 to'91
0
Left
1245
292.625
90
none
Existing
No
E-399
A
Def Wall'78 to'91
90
Back
399
61.19
90
none
Existing
No
S-210
A
Def Wall'78 to'91
180
Right
210
53.17
90
none
Existing
No
W-680
A
Def Wall'78 to'91
270
Front
680
244.872
90
none
Existing
No
NEXT
DWELLING I
A
Def Wall'78 to'911
n/a
n/a
1078
0
n/a
Existing
No
TO GARAGE
A
Def Wall'78 to'911
n/a
n/a
343
0
n/a
Existing
No
2846
A
Def Roof ' to
Presentt
n/a
n/a
2846
n/a
n/a
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool Roof
Status
Verified Existing
Condition
Attic
Attic RoofA
Ventilated
4
0.1
0.85
No
No
Existing
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Name
Type
Surface
Orientation
Azimuth
Width
(it)
Height
(ft)
Mult.
Area
(ft2)
U-factor
U-factor
Source
SHGC
SHGC
Source
Exterior
Shading
Status
Verified
Existing
Condition
48.5x62.25 - 11
Window
N-1245
Left
0
4.04
5.18
0
20.84
0.36
NFRC
0.26
NFRC
Bug Screen
Altered
No
93.5x78.25-7
Window
N-1245
Left
0
7.79
6.52
1
50.79
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
90.5X56-8
Window
N-1245
Left
0
7.5
4.66
1
35.19
0.36
NFRC
0.26
NFRC
Bug Screen
I Altered
I No
33.5X56.25-6
Window
N-1245
Left
0
2.79
4.66
2
35.19
0.36
NFRC
0.26
NFRC
Bug Screen
Altered
No
33.5X56.25-5
Window
N-1245
Left
0
2.79
1 4.66
1 2
35.19
0.36
1 NFRC
1 0.26
1 NFRC
Bug Screen
I Altered
No
33.5X5625-4
Window
N-1245
Left
0
2.79
4.66
1 2
35.19
0.36
1 NFRC
1 0.26
1 NFRC
Bug Screen
Altered
No
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time:2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CFIR-PRF-01E
(Page 4 of 10)
FENESTRATION / GLAZING
01
02
03
04
OS
06
07
08
09
10
11
12
13
14
is
16
Name
Type
Surface
Orientation
Azimuth
Width
Ift)
Height
(ft)
Mult.
Area
(it)
U-factor
SourceSource
SHGC
SHGC
Source
Exterior
Shading
Status
Verified
Existing
Condition
21.5XS6.25-3
Window
N-1245
Left
0
1.79
4.68
1
8.39
0.36
NFRC
0.26
NFRC
Bug Screen
Altered
No
116.75X78.25 - 2
Window
N - 1245
Left
0
9.66
6.52
1
63.42
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
21.SX56.25-1
Window
N-1245
Left
0
1.79
4.69
1
8.39
0.36
NFRC
0.26
NFRC
Bug Screen
Altered
No
93.5X94.25 - 18
Window
E-399
Back
90
1
61.19
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
81.5X94.25 - 17
Window
5-210
Right
180
1
53.17
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
164X94.25-13
Window
W-680
front
270
7.79
7.85
1
102'3
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
54.SX62.25 - 12
Window
W-680
Front
270
4.54
5.18
1
23.54
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
78.5X41.25 - 10
Window
W-680
Front
270
6.54
3.43
0
22.41
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
69.5X78.2S-9
Window
W-680
Front
270
1 5.79
1 6.52
1 1
137.751
0.47
1 NFRC
1 0.24
1 NFRC
I Bug Screen
Altered
No
13.75X84.5 - 14
Window
W-680
Front
270
1
8.06
0.36
NFRC
0.26
NFRC
Bug Screen
Altered
No
57.SX94.5-15
Window
W-680
Front
270
1
37.73
0.47
NFRC
0.24
NFRC
Bug Screen
Altered
No
13.75X84.5 - 16
Window
W-680
Front
270
1
8.06
0.36
NFRC
0.26
NFRC
Bug Screen
Altered
No
OVERHANGS AND FINS
O1
02
1 03
1 04
1 OS
06
07
1 08
1 09
1 10
11
1 12
1 13
14
IS
16
17
Overhang
Left Fin
Right Fin
Window
Left
Right
Verified
Existing
Depth
Dist Up
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
Status
Existing
Extent
Extent
Condition
Construction
48.5x62.25 - 11
3
0.1
3
3
0
0
0
0
0
0
0
0
0
Alt
No
93.508.25 - 7
8
0.1
8
8
0
0
0
0
0
0
0
0
0
red
No
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards- 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CF1R-PRF-01E
(Page 5 of 10)
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
1 09
10
11
12
1 13
14
15
16
17
Overhang
Left Fin
Right Fin
Window
Verified
Depth
Dist Up
Left
Right
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
Status
Existing
Existing
Extent
Extent
Condition
Construction
90.5X56-8
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Alto
No
33.5X56.25 - 6
3
0.1
3
3
0
0
0
0
0
0
0
0
0
Alto
No
red
33.5X56.25 - 5
3
0.1
3
3
0
0
0
0
0
0
0
0
0
Alto
No
33.5X56.25-4
3
0.1
3
3
0
0
0
0
0
0
0
0
0
red
No
21.5X56.25 - 3
3
0.1
3
3
0
0
0
0
0
0
0
0
0
Alt
No
ed
116.75X78.25 - 2
3
0.1
3
3
0
0
0
0
0
0
0
0
0
Alte
No
ed
21.SX56.25-1
3
0.1
3
3
0
0
0
0
0
0
0
0
0
Alte
No
ed
164X94.25 -13
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Alto
No
54.5X62.25 - 12
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Alto
No
ed
78.5X41.25 -10
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Aed
No
69.SX78.25-9
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Alto
No
ed
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CFiR-PRF-01E
(Page 6 of 10)
SLAB FLOORS
01
02
03
04
05
06
07
08
09
10
Edge Insul.
Edge Insui.
Name
Zone
Area lftZ)
Perimeter (ft)
R-value and
R-value and
Carpeted Fraction
Heated
Status
Verified Existing
Depth
Depth
Condition
28462
A
2846
0.1
none
0
80%
No
Existing
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Total Cavity
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
R-value
Continuous
U-factor
Assembly Layers
R-value
Inside Finish: Gypsum Board
Def Wall'78 to'91
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. 0. C.
R-11
None / None
0.11
Cavity/ Frame: R-11 / 2x4
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
Def Wall'78 to'911
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O. C.
R-11
None / None
0.099
Cavity/ Frame: R-11 / 2x4
Other Side Finish: Gypsum Board
Roofing: Light Roof (Asphalt Shingle)
Attic RoofA
Attic Roofs
Wood Framed
2x4 @ 24 in. O. C.
R-0
None /None
0.644
Roof Deck: Wood
Ceiling
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Ceilings (below
Wood Framed
Over Ceiling Joists: R-1.9 insul.
Def Roof' to Present
attic)
Ceiling
2x4 @ 16 in. O. C.
R-11
None / None
0.083
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
High R-value Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1,300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CF1R-PRF-01E
(Page 7 of 10)
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Verified
Existing
Name
System Type
Distribution Type
Water Heater Name (#)
Solar Heating
Compact
HERS Verification
Status
Existing
Water
System
Distribution
Condition
Heating
System
Domestic Hot
Standard
DEW Sys 1
Water (DHW)
Distribution
DHW Heater 1(1)
n/a
None
n/a
Existing
No
System
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Heating
# of
Tank
Energy
Input Rating
Tank
Insulation
Standby
1st Hr.
NEEA Heat Pump
Tank Location
Verified
Name
Element
Tank Type
Units
Vol.
Factor or
or Pilot
R-value
Loss or
Rating or
Brand or Model
or Ambient
Status
Existing
Type
(gal)
Efficiency
(Int/Ext)
Recovery Eff
Flow Rate
Condition
Condition
DHW
Gas
Small Storage
1
50
0.53-EF
0
78
n/a
n/a
n/a
Existing
No
H
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Compact Distribution
CompType
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1- 1/1
Not Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards- 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-10T00:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CF1R-PRF-01E
(Page 8 of 10)
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
Heating Unit
Cooling Unit
Distribution
Required
Verified
Heating
Cooling
Name
System Type
Name
Name
Fan Name
Name
Thermostat
Status
Existing
Equipment
Equipment
Type
Condition
Count
Count
Heating and cooling system
Heating
Cooling
Air
(E) HAVC1
other
Component
Component
HVAC Fan 1
Distribution
n/a
Existing
No
1
1
1
1
System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Heating Efficiency
Heating Component 1
Central gas furnace
1
AFUE-78
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency EER/LEER
Efficiency SEER
Zonally Controlled
Mulit-speed
Compressor
HERS Verification
Cooling Component 1
Central split AC
1
8
8.1
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
1 05
06
07
1 09
09
1 10
11
12
13
14
15
16
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design
Supply
Return
Supply
Return
Supply
Return
Bypass
Duct
HERS
Status
Verified
Existing
Existing
Distribution
New Ducts
Type
Duct
Leakage
Verification
40 ft
Condition
system
Air
Distributi
Unconditioned
Non-
No
Existing
Air
attic
Verified
R-2.1
R-2.1
Attic
Attic
n/a
n/a
Bypass
(not
Distributi
Existing
No
n/a
n/a
on
System 1
Duct
specified)
on System
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards- 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 2021-03-1OTOO:54:13-08:00
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
CF1R-PRF-01E
(Page 9 of 10)
HVAC - DISTRIBUTION SYSTEMS
O1
02
03
04
1 05
06
07
08
09
10
11
12
13
14
35
16
Duct Ins. R-value
Duct Location
Surface Area
Design
Bypass
Duct
HERS
Verified
Existing
New Ducts
Name
Type
Supply
Return
Supply
Return
Supply
Return
Status
Existing
Distribution
Type
Duct
Leakage
Verification
40ft
Condition
system
1-hers-
dist
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan
Not Required
0
PROJECT NOTES
--ALL PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER.
--ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY.
-- LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER.
--AC EQUIPMENT'S EFFICIENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT.
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: CHIBRI RESIDENCE
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2021-03-1OT00:54:13-08:00 (Page 10 of 10)
Input File Name: 005 -54621 SOUTHERN HILLS.ribdl9x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
ON -r
Company:
Signature Date:
3/10/2021
TITLE 24 OF THE DESERT SERVICES INC.
Address:
CEA/ HERS Certification Identification (If applicable):
title24ofthedesert@gmaii.com
City/State/Zip:
Phone:
760 278.1840,
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name: I
Responsible Designer Signature:
p
9u
Company:
Date Signed:
MR. CHIBRI
t
Address:
54621 SOUTHERN HILLS
License: (�
WD U ( �
t�
City/State/Zip:
LA QUINTA, CA 92253
Phone:
-- 0 - �� r
p�'
0 j
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-03-10 00:54:43
Schema Version: rev 20200901
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
CHIBRI RESIDENCE'S alteration
Building Type
2 Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration 1311012021
Date
Project Address
54621 SOUTHERN HILLS
LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,846
Addition
0
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Roof Wood Framed Attic
R11
Z846 Existing
Slab Unheated Slab -on -Grade
-
no insulation
Z846 Perim = 0' Existing
Wall Wood Framed
R 11
952 Existing
Wall Wood Framed
R 11
338 Existing
Wall Wood Framed
R 11
157 Existing
Wall Wood Framed
R 11
435 Existing
Demising Wood Framed
R 11
1,078 Existing
Demising Wood Framed
R 11
343 Existing
FENESTRATION
Orientation Area(ft)
Total Area: 652 Glazing Percentage: 229% 1 New/Altered Average U-Factor: 0.44
U-Fac SHGC Overhang Sidefins Exterior Shades Status
Left (N) 143.2
0.360
0.26 3.0
none NIA Altered
Left (N) 50.8
0.470
0.24 6.0
none N/A Altered
Left (N) 35.2
0.360
0.26 8,0
none N/A Altered
Left (N) 63.4
0.470
0.24 3.0
none NIA Altered
Rear(E) 61.2
0.470
0.24 none
none N/A Altered
Right(S) 53.2
0.470
0.24 none
none N/A Altered
Front (VV) 191.1
0A70
0.24 8.0
none N/A Altered
Front(V✓) 16.1
0.360
0.26 none
none N/A Altered
Front (LAB 37.7
0.470
0.24 none
none N/A Altered
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff Thermostat Status
1 Central Furnace
78%AFUE
Split Air Conditioner 8.1 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value Status
(E) HAVC Ducted
Ducted
Attic 2.1 Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro8.2 by EnergySott User Number., 20648
ID. 21 - CWMT - 005
Pa e 13 of 17
2019 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply.
01/2020
Building Envelope Measures:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less
when tested per NFRC400 ASTM E263 or AAMAIWDMA/CSA 101/I.S.2/A440-2011:
§ 110.6(a)5:
Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a).
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables
§110.6(b):
110.6-A, 110.6-B, or JA4.5 for exterior doors. Theymust be caulked and/or weather-stripped.*
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
§ 110.7:
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods
and Services BHGS .
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated perthe requirements of § 110.8(g).
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
§ 110.8(i):
material must meet the requirements of § 110.8 and be labeled er 10-113 when the installation of a cool roof is specified on the CF1R.
§ 110.80):
Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0,043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exflltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturers required density forthe labeled R-value.
Wall Insulation, Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or
§ 150.0(c):
have a U-factor of 0.071 or less. Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls
must meet Tables 150.1-A or B:
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
§ 150.0(f):
facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and
UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g).
Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor
§ 150.0(g)l:
retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to§ 150.0 d .
Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150A(g)2:
insulation in all exterior walls, vented aftics, and unvented attics with air -permeable insulation.
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
§ 150.0(q):
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58:
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 110.5(e)
Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces.
§ 150.0(e)l:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
§ 150.0(e)2:
and is equipped with a readily accessible, operable, and fight -fitting damper or combustion -air control device.'
§ 150.0(e)3:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
Space Conditioning, Water Heating, and Plumbing System Measures:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
§ 110.0-§ 110.3:
a liances must be certified by the manufacturer to the California Energy Commission."
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.`
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
out -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
§1102(c):
setback thermostat:
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)4:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of
110.3 c 4,
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose
§ 110.3(c)6:
bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (except
§ 110.5:
appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour); and pool and spa heaters:
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook,
§ 150.0(h)l:
Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards
Manual; or the ACCA Manual J using design conditions specified in § 150A(h)2.
a2019 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer
Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the
§ 150.0(h)3B:
manufacturers instructions.
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
§ 150.00)1:
a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water Piping, Solar Water -heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must
be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum
§ 150.00)2A:
insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot
water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hotwater piping with a nominal diameter less
than 314 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks,
buried below grade, and from the heating source to kitchen fixtures.*
Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.OQ)3:
wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes).
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a
Class I or Class 11 vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non -crushable casing or sleeve.
Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of
the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG
copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the
§ 150.0(n)l:
word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker
for the branch circuit and labeled with the words "Future 240V Use'; a Category III or IV vent, or a Type B vent with straight pipe between the
outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base
of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
§ 150.0(n)3:
Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing
agency that is approved by the Executive Director.
Ducts and Fans Measures:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604,0 of the California Mechanical Code (CMC). If a
§ 110,8(d)3:
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0
and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and
plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned
space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and
surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be
§ 150.0(m)l:
mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL
181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y.
inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums
designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air.
Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause
reductions in the cross -sectional area:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
§ 150.0(m)3:
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers.
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
§ 150.0(m)8:
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed
§ 150.0(m)9:
to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular
foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non -porous layer between the inner core and outer vapor harder.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)l1:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
Air Filtration. Spare conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or
§ 150.0(m)12:
equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure
drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.*
Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole
for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be z 350 CFM
§ 150.0(m)13:
per ton of nominal cooling capacity, and an air -handling unit fan efficacy <_ 0.45 wafts per CFM for gas furnace air handlers and 5 0.58 watts per
CFM for all others. Small duct high velocity systems must provide an airflow>: 250 CFM per ton of nominal cooling capacity, and an air -handling
unit fan efficacy 5 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.*
a2019 Low -Rise Residential Mandatory Measures Summary
Requirements for Ventilation and Indoor Air Quality:
Requirements for Ventilation and Indoor Air Quality, All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation
§ 150.0(o)1:
and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1.
Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with
§ 150.0(o)lC:
other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates
determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1 C.
Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in
accordance with Equation 150.0-B and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced
§ 150.0(0)1 E:
system is not used, all units in the building must use the same system type and the dwelling -unit envelope leakage must be 5 0.3 CFM at 50 Pa
(0.2 inch water) per square foot of dwelling unit envelope surface area and verifed in accordance with Reference Residential Appendix RA3.8.
Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide
§ 150.0(o)1F:
ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150,0-B. All unit airflows must be
within 20 percent of the unit with the lowest airflow rate as it relates to the individual units minimum required airflow rate needed for compliance.
§ 150.0(o)1G:
Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2.
Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential
§ 150.0(o)2:
Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3,7,4.3 to confirm it is
rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
Without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or
§ 110.4(b)1:
dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
§ 110.4(b)3:
will allow all pumps to be set or programmed to run only durin off-peak electric demand perods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
§ 150.0(p):
rate, piping, filters, and valves.'
Lighting Measures:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
§ 110.9:
of § 110.9:
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or
§ 150.0(k)l B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
§ 150.0(k)1C:
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C.
Electronic Ballasts for Fluorescent Lamps, Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an
§ 150.0(k)1 D:
output frequency no less than 20 kHz.
§ 150.0(k)1E:
Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be
controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens.
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
§ 150.0(k)1F:
must meet the applicable requirements of § 150.0 k :
§ 150.0(k)1G:
Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8:
§ 150.0(k)1H:
Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated
temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to
§ 150.0(k)11:
comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no
more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed.
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.'
Interior Switches and Controls. Lighting must have readily accessible wall -mounted controls that allow the lighting to be manually
§ 150.0(k)2C:
turned ON and OFF.*
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturers instructions.
Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensorfunction if the control is installed to
§ 150.0(k)2E:
comply with § 150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
2019 Low -Rise Residential Mandatory Measures Summary
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it:
§ 150.0(k)2G:
provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the
EMCS requirements of § 130.0 e ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
§ 150.0(k)2H:
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
§ 150.0(k)21:
be controlled by an occupant sensor or a vacancy sensor providing automatic -off functionality. If an occupant sensor is installed, it must be
initially configured to manual -on operation using the manual control required under Section 150.0(k)2C.
Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for
§ 150.0(k)2J:
dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.'
§ 150.0(k)2K:
Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling -installed lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either
150.0 k 3Aii(photocell and either a motion sensor or automatic time switch control or § 150.0 k 3Aiii astronomical time clock), or an EMCS,
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances,
§ 150.0(k)3B:
balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either § 150.0(k)3A or
with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots
§ 150.0(k)3C:
or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by § 150.0(k)3B or § 150.0(k)3D must comply with
the applicable requirements in Sections 110.9,130.0, 130.2, 130A, 140.7 and 141.0.
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
§ 150.0(k)4:
power as determined according to § 130.0(c).
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
§ 150.0(k)5:
applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4,140.6, and 141.0.
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be comply with Table 150.0-A and be controlled by an occupant sensor.
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in
§ 150.0(k)6B:
that building must:
i, Complywith the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and
H. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which
do not have a photovoltaic system installed must comply with the requirements of 110.10 b through § 110.10 e .
Low-rise Multifamily Buildings. Low-rise multi -family buildings that do not have a photovoltaic system installed must comply with the
§ 110.10(a)2:
requirements of § 110.10(b) through § 110.10(d).
Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access,
pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by
a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80
square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with
§ 110.10(b)1:
roof areas greater than 10,000 square feet. For single family residences, the solarzone must be located on the roof or overhang of the building
and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of
the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the
building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone
requirement is applicable to the entire building, including mixed occupancy.'
§ 110.10(b)2:
Azimuth. All sections of the solar zone located on steep -sloped roofs must be oriented between 90 degrees and 300 degrees of true north.
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
§ 110.10(b)3A:
mounted a ui ment'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof
§ 110.10(b)4:
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a
§ 110.10(c):
pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family
residences and central water -heating systems, a pathway reserved for routing plumbing from the solar zone to the water -heating system.
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110,10(b) through
§ 110.10(d):
§ 110.1 0c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be permanently marked as "For Future Solar Electric'.