HomeMy WebLinkAboutBELC2023-0021BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Electrical
Permit Number:
BELC2023-0021
Property Address:
47815 VIA TRIESTE
APN:
643130048
Legal Description
Property Zoning:
Valuation:
$503.10
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 02/08/2023
ISSUED DATE: 02/14/2023
CALIFORNIA
Owner: ALLEN MARK C
47815 VIA TRIESTE, LA QUINTA, CA 92253
Applicant: JAMES HEGGE
83852 Avenue 45, Indio, CA 92201
Contractor: JAMES HEGGE / 748171
83852 Avenue 45, Indio, CA 92201
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 5/5/26 8:18 am Page 1 of 3
Permit Type
Electrical
BUILDING PERMIT
Permit Number:
Property Address
BELC2023-0021
47815 VIA TRIESTE
ALLEN / INSTALL (1) 240V 60AMP DEDICATED CIRCUIT AT GARAGE ... INSTALL (1) 240V 60AMP DEDICATED CIRCUIT AT GARAGE
FOR VEHICLE CHARGING. 2022 CALIFORNIA BUILDING CODES.
New Electrical Square 0 Number of Residential 1
Footage Appliances
Type Group Sq Ft Value
Invoice No. Fee
PERM IT-BELC2023-002 BSAS SB1473 FEE
APPLIANCES, RES
PERMIT ISSUANCE
APPLIANCES, RES PC
TECHNOLOGY ENHANCEMENT FEE
RECORDS MANAGEMENT FEE
Total for Invoice PERM IT-BELC2023-0021
Fee Amount
Amount Paid
$1.00
$1.00
$14.59
$14.59
$110.88
$110.88
$14.59
$14.59
$8.00
$8.00
$11.00
$11.00
$160.06
$160.06
Grand Total for Permit $160.06 $160.06
Workflow Step / Action Name Action Type Start Date End Date
Inspections v.1 02/08/2023 0:00
ELECTRICAL FINAL— v.2 Inspection
ELECTRICAL FINAL— v.1 Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Printed: 5/5/26 8:18 am Page 2 of 3
BUILDING PERMIT
Permit Type: Electrical
Permit Number: BELC2023-0021
Property Address: 47815 VIA TRIESTE
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
iurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the buildina official.
Printed: 5/5/26 8:18 am Page 3 of 3
WIRING FOR 60AMP EV CHARGER
Customer Name_MarkAllen
Project Address_ 47815 Via Trieste, La Quinta CA 92253
Garage
11 Hardwired 60amp EV Charger
iervice Panel 200amp
BELC2023-0021
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE COM PLIANCE
By: A. DATE 02/0ei12023
INSTALL (1) 240V 60AMP
DEDICATED CIRCUIT AT
GARAGE FOR VEHICLE
CHARGING. 2022
CALIFORNIA BUILDING
CODES.
❑ 2 Pole 50 Amp Breaker w/ G13 Cu Romex (m wall)
----❑—Jt�i`IY�&i'd—i-4-��-�eEe�9t188i-i19St-�il------------- - - ----
0 Standard 40 1 Amp Charging Station In5tall 02 Pole 40 Amp Breaker ,w/3 #8 + 1 #8 Grid 3/4" Conduit
)95tandard 60 Amp Charging Station In5tall ❑ 2 Pole 50 Amp Breaker w/ Combination Of Romex € Conduit
❑ 2 Pole GO Amp Breaker w/ 413 Cu Romex (in wall)
❑ Standard 90 Amp Charging Station In5tall 2 Pole GO Amp Breaker w/2 #GCu + #8 Grid 3/4" Conduit
❑ 2 Pole 90 Amp Breaker w/ 2/3 Cu Romex (in Wall)
❑ 2 Pole 90 Amp Breaker w/ 2#4 Cu + #8 Gnd I" Conduit
hegge Electrical Contractors Inc. XEw5ting s Service 200 Amp
83-8 J2 Ave. 45 ❑ Exi5ting 5ennce 400 Amps
Indio, Ca. 92201 X Denotes Outlet or Charging Station Location
Lic# 748171
83852 AVENUE 45 INDIO, CA 92201
CA. LIC# 748171
ELECTRICAL LOAD CALCULATION
CUSTOMER Mark Allen
DATE February 3, 2023
BELC2023-0021
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
COD E COM PUAN CE
BY: A. /l am, DATE 091099190-93
SQUARE FEET LIVING
2,036
3
6,108
GD
672
1
672
DW
1,380
1
1,380
SMALL APPLIANCES
1,500
3
4,500
MICRO
1,680
1
1,680
CART CHARGER
0
0
0
DUAL FUEL RANGE
8,100
0
0
SINGLE OVEN
4,800
1
4,800
COOKTOP-GAS
720
1
720
WASHER
720
1
720
GAS DRYER
960
1
960
ELECTRIC PATIO HEATERS
0
0
0
WATER COOL
1,080
0
0
POOL POWER 50 AMP
3,840
1
3,840
LANDSCAPE FUTURE
1,200
1
1,200
TOTAL -KW
26,580
PERCENT
KW
1st 10,000 KW
100%
10,000 10,000
REMAINDER
40 %
16,580 6,632
EV CHARGER 60
11,520
1
100%
11,520
FURNACE
1,500
1
100%
1,500
A/C COMPRESSORS #1
6,648
1
100%
6,648
A/C COMPRESSORS #2
5,064
0
100%
0
A/C COMPRESSORS #3
3,960
0
100%
0
A/C COMPRESSORS #4
1,494
0
100%
0
TOTAL
36,300
DIVIDED BY
240 V
151.25 AMPS
USE
200 AMP SERVICE
T-SLn
Gen 3 Wall Connector Manual
48A Single Phase
r
PRODUCT OVERVIEW
This manual applies to Wall Connectors identified by part number 1457768-**-*
Product Specifications
Voltage and Wiring Nominal 200-240 V AC single-phase
Current Output Range 12 - 48 amps
Terminal Blocks 12-4 AWG (3.5 - 25 mm2), copper only
Supported Conduit Sizing 3/ in (21 mm) default, 1 in (27 mm) optional
Grounding Scheme TN/TT
Frequency 50/60 Hz
Cable Length 7.3 m (24 ft)
Wall Connector Dimensions
Height: 13.6 in (345 mm)
Wire Box Bracket Dimensions
Width: 6.1 in (155 mm)
Depth: 4.3 in (110 mm)
Height: 9.8 in (250 mm)
Width: 4.7 in (120 mm)
Depth: 2.0 in (50 mm)
Weight (including wirebox) 10 Ib. (4.5 kg)
Operating Temperature -22°F to 122°F (-30°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85°C)
Enclosure Rating Type 3R
Ventilation Not required
Means of Disconnect External branch circuit breaker
Ground Fault Circuit Interrupter Integrated, no additional required (CCID20)
Wi-Fi 2.4 GHz, 802.11b/g/n
Agency Approvals cULus - E351001
Transportation and storage: Ensure that Wall Connector is within storage temperature when moving,
transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Gen 3 Wall Connector Manual 5
PRODUCT OVERVIEW
Circuit Breaker Rating / Maximum Output
Power Output
For maximum power output, install a standard double pole 60 amp circuit breaker. Wall Connector includes
integrated GFCI protection - do not install a GFCI circuit breaker.
Wall Connector incorporates automatic load management, which allows the max output to be customized to
an existing power supply. If the electrical supply is unable to support the 60 amp configuration, select a
lower amperage configuration.
Circuit breaker (amps)
60
50
40
30
20
15
Max output (amps)
48
40
32
24
16
12
Power output at 240 volts (kW)
.i NOTE: External disconnect switches are neither required nor recommended.
11.5
9.6
7.6
5.7
3.8
2.8
.i NOTE: Circuit breaker size is programmed during the commissioning process. See Commissioning
Procedure on page 28 for details.
.i NOTE: Some Tesla vehicles may draw less current than the max output. Actual charging rate depends
on Wall Connector output and onboard charger in the vehicle.
Branch Circuit Conductors and Ground Wire
• If installing for less than maximum power, refer to local electrical code to select correct conductors
and ground wire size that are suitable for the chosen circuit breaker.
• If installing for maximum power, use minimum 6 AWG, 90' C-rated copper wire for conductors.
.i NOTE: Upsize conductors if necessary.
• For sites with multiple Wall Connectors, each Wall Connector must have its own branch circuit with L1,
L2/N, and Ground.
• COPPER WIRE TERMINATIONS ONLY for landing in Wall Connector wirebox terminals. Conductors
can be stranded or solid.
• Hardwire branch circuits to disconnects or circuit breakers. Do NOT install cord -and -plug type
connections.
• For outdoor installations, use watertight fittings when securing feeder wires to the wirebox.
Gen 3 Wall Connector Manual 6
PRODUCT OVERVIEW
Grounding Connections
Wall Connector must have a ground path back to the main equipment earthing point on site. Without a
proper ground connection, the Wall Connector will fault during a ground assurance test. Equipment -
grounding conductor must be run with the circuit conductors and connected to the equipment -grounding
terminal in the wirebox. Install a ground (PE) wire sized according to local electrical code.
Gen 3 Wall Connector Manual