Loading...
HomeMy WebLinkAboutBPOL2022-0271 March 10, 2022 Mr. Richard Doan PO Box 8011 Rancho Santa Fe, CA 92067 Re: Lot 39A 53821 Ross Avenue Dear Mr. Doan: The Design Review Committee reviewed your Final Working Drawings submittal at its March 10th meeting and agreed that all the previous comments had been addressed. The project is approved to go to construction. Please contact Zoe Lombard the HOA manager when you are ready to schedule a preconstruction meeting. You may contact me via e-mail at: madisondrc@gmail.com with any questions regarding this submittal. Sincerely, MADISON CLUB DESIGN REVIEW COMMITTEE Christopher Andrews Design Review Committee Coordinator cc: DRC File Mark Radford Architecture Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of Directors for the Association. If you wish to pursue an appeal, please contact the Association’s property manager so that you may be put on the next meeting agenda. 06 - 2 1 - 2 2 DR A W N RE V I S I O N SC A L E : 1 / 1 6 " = 1 ' - 0 " LA N D S C A P E P L A N L-1 . 0 DE S I G N E D B Y : L U I S A L V A R A D O DR A W N B Y : A N A I ÑIG U E Z 53821 ROSS AVENUE LA QUINTA, CA 92253 MADISON C. C. LOT 39A RESIDENCE LANDSCAPE PLAN FOR SH E E T LANDSCAPE DESIGN BY: PO B O X 2 9 1 3 IN D I O , C A 9 2 2 0 2 TE L E P H O N E : ( 7 6 0 ) 3 4 7 - 5 0 2 2 EM I A L : O F F I C E @ S A N D S T O G R E E N S . C O M LIC E N S E : N O . 8 9 1 2 5 1 (C - 2 7 ) , ( C - 6 1 / D 1 2 ) , ( C - 6 1 / D 0 6 ) , ( C - 5 3 ) SA N D S T O G R E E N S LA N D S A P E I N C . RE V I S E D 07 - 0 1 - 2 2 LOT 39A RESIDENCE 3' 0" 44' 0" THESE DRAWINGS AND SPECIFICATIONS ARE AN INSTUMENT OF SERVICE AND REMAIN THE PROPERTY OF SANDS TO GREENS LANDSCAPE INC. THEY ARE NOT TO BE REPORDUCED OR ALTERED IN ANY WAY, NOR DISCLOSED OR ASSIGNED TO ANY THIRD PARTY WITHOUT THE WRITTEN CONSENT OF SANDS TO GREENS LANDSCAPE INC. (9) - JANDY VARIABLE SPEED 2.7 HP (3) - CV 460 (2) POOL-JANDY JXI 400 BTU JANDY AUTOMATED SYSTEM JANDY SALT SYSTEM 53 LIN FT 163 SQ FT 17' X 10' (8) LIGHTS DATE:SIGNATURE: A: DETERMINE THE APPROPRIATE POOL OR SPA ELEVATION AT TIME OF LAYOUT. B: AGREE THAT SANDS TO GREENS LANDSCAPE INC. IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS OR OTHER ITMES IN THE AREA. C: WET DOWN CONCRETE SHELL AT LEAST ONCE A DAILY FOR SEVEN DAYS AFTER INSTALLED. D: POOL EQUIPMENT LOCATION SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT. E: FILL POOL IMMEDIATELY AFTER PEBBLE OR PLATER (FOLLOW INSTRUCTIONS). F: OWNER APPROVES PLAN, POOL AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONISIBILITIES AND NOTICES ABOVE. OWNER RESPONSIBILIIES: WATERLINE: FINISHES SYSTEM: LIGHTS: SKIMMER: TIME CLOCK: HEATER: FILTER: PUMP: PLUMBING SPA PERIMETER SPA SURFACE AREA SPA SIZE SPA SPECS POOL PERIMETER 214 LNFT 2104 SQ FT POOL SURFACE AREA 36' X 18' POOL SIZE POOL SPECS JETS: 1 15 AUTOFILL:1 PLASTER: PEBBLE POOL & SPA COPING 6" TILE (1) SPA-JANDY JXI 400 BTU (4) NICHLESS LIGHTS 190 LNFT 277 SQ FT 92' X 3' INFINITY BASIN SIZE INFINITY BASIN SPECS BASIN PERIMETER BASIN SURFACE YARD YARD PO O L RQ U I P M E N T EXISTING 6' WALL EXISTING 6' WALL COURTYARD PROP ERTY LINE PROPERTY LINE -6" -12" -4'W.D. -4'W.D. INFINITY DETAIL WITH TILE KNIFE EDGE AND TILE VENEER FACING (TILE TO BE SUPPLIED BY GENERAL CONTRACTOR AND INSTALLED BY SAND TO GREENS TANING LEDGE INFINITY EDGE LOWER BASIN AT -15" WITH 16" X 24" 5CM TRAVERTINE CAP CUT TO FIT. CAP TOBE SUPPLIED BY GENERAL CONTRACTOR AND INSTALLED BY SAND TO GREENS. PEBBLE TEC WATER LINE TILE 16" X 24" CAP 5CM TRAVERTINE COPING KNIFE EDGE TILE PEBBLE TEC GUNITE SHELL INFINITY EDGE DETAIL TILE BY GENERAL CONTRACTOR WATER LINE NOT TO SCALE FINISH GRADE COMPACTED SUBGRADE SPILLWAY POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART ANTI-ENTRAPMENT VORTEX COVERS 10" ANSI APPROVED SPA AT -0- WITH 12" DAM WALL, 6" WATER LINE TILE, PEBBLE TEC INTERIOR, WITH 15 HYDRO THERAPY JETS AT ALTERN HIEGHTS WITH DEDICATED SPA BOOSTER TILE AND CAP INSTALLED BY SAND TO GREENS AND SUPPLIED BY GENERAL CONTRACTOR FIRE PIT BY OTHERS FIRE PIT BY OTHERS SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART ANTI-ENTRAPMENT VORTEX COVERS 10" ANSI APPROVED TOP OF GUNITE -5" BELOW TOP SLAB OF FOUNDATION 16" X 24" 5CM TRAVERTINE COPING MATERIAL TO BE SUPPLIED BY GENERAL CONTRACTOR AND INSTALL BY SAND TO GREENS. PROPERTY LINE EXISTING 6' WALL EXISTING 6' WALL -2'6" 1. OUR EMPLOYEES AND SUB-CONTRACTORS WILL USE PORTABLE TOILET LOCATED AT CONSTRUCTION SITE. 2. OUR EMPLOYEES AND SUB-CONTRACTORS WILL DIPOSE OF CONSTRUCTION DEBRIS ON SITE. 3. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT PROPERTIES WILL NOT BE UTILIZED. THE PUBLIC RIGHT OF WAY SHALL BE MAINTAINED IN CLEAR CONDITION AT ALL TIMES. SAFETY FEATURES: * ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) ELECTRICAL: EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. GOVERNMENT CODE SECTION 4216 2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114-MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATER, POOL EQUIPMENT SHALL BE INSTALLED PER MAUNFACTURE'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS LA QUINTA MUNICIPAL CODE REQUIREMENTS: CONSTRUCTION HOURS: OCTOBER 1ST THRU APRIL 30TH MONDAY - FRIDAY 7:00 A.M. - 5:30 P.M. SATURDAYS 8:00 A.M. - 5:00 P.M. SUNDAYS NOT ALLOWED GOVERNMENT CODE NOT ALLOWED HOLIDAYS SPA TO BE EQUIPPED WITH ANTI-ENTRAPMENT DEVICE (SEC. 1404 FEDERAL SWIMMING POOL AND SPA DRAIN COVER STANDARD) NOTE: ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03 FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO INSPECTION APPROVAL PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT STADRADS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME). IDENTIFY A MINIMUM 3 FEET SEPERATION BETWEEN ALL DRAINS AND NOTE HYDRAULICALLY BALANCED MAY 1ST THRU SEPTEMBER 30TH MONDAY - FRIDAY 5:30 A.M. - 7:00 P.M. SATURDAYS 8:00 A.M. - 5:00 P.M. SUNDAYS NOT ALLOWED GOVERNMENT CODE NOT ALLOWED HOLIDAYS 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA ENERGY EFFICIENCY STANDARDS 2019 CALIFORNIA FIRE CODES (BASED ON 2006 IBC) (BASED ON 2006 UMC) (BASED ON 2006 UPC) TITLE 24. PART 5 (BASED ON 2006 NEC) NOTE: 1. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED 2. MASONRY EQUIPMENT WALL SHALL BE BUILT PER CITY STANDARD SPECIFICATIONS 3. ALL GFI OUTLETS WILL BE WEATHER AND TAMPER PROOF 4. ALL OUTLETS SUPPLIED BY SINGLE-PHASE, 15A AND 20A, 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION 5. PROVIDE 36" WORKING CLEARANCE FOR THE POOL EQUIPMENT MOTORS ARE REQUIRED 6. LED LIGHTS REQUIRE WATER BONDING. 7. POOL HEATER/POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURE INSTALLATION SPECIFICATIONS. 8. POOL EQUIPOTENTIAL BONDING PERIMETER SURFACE PER 2019 CEC 680.26. 9. PROVIDE ADEQUATE WORKSPACE AROUND ELECTRICAL EQUIPMENT PER 2019 CEC 110.26. 10. INSTALL AN APPROVED FLOATING SAFETY POOL ALARM. NORTH ROSS AVENUE GUEST HOUSE 3' 0" 79' 0" 90' 0" 10' 0" 92' 0" 10' 0" GASLINE TO POOL EQUIPMENT SUPPLIED AND INSTALLED BY GENERAL CONTRACTER ELECTRICAL LINE TO POOL EQUIPMENT SUPPLIED AND INSTALLED BY GENERAL CONTRACTER ELECTRICAL SUBPANEL WITH POOL EQUIPMENT DISCONNECTION (BY STG) 22' 0" 3' 0" 42' 0" SLAB AND FOUNDATION BY OTHERS 21' 0" 0" 0" 3' 0" 3' 0" US US US