March 10, 2022
Mr. Richard Doan
PO Box 8011
Rancho Santa Fe, CA 92067
Re: Lot 39A 53821 Ross Avenue
Dear Mr. Doan:
The Design Review Committee reviewed your Final Working Drawings submittal at its March
10th meeting and agreed that all the previous comments had been addressed. The project is
approved to go to construction.
Please contact Zoe Lombard the HOA manager when you are ready to schedule a
preconstruction meeting.
You may contact me via e-mail at: madisondrc@gmail.com with any questions regarding this
submittal.
Sincerely,
MADISON CLUB DESIGN REVIEW COMMITTEE
Christopher Andrews
Design Review Committee Coordinator
cc: DRC File
Mark Radford Architecture
Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of Directors for the Association. If you wish to pursue an
appeal, please contact the Association’s property manager so that you may be put on the next meeting agenda.
DR
A
W
N
RE
V
I
S
I
O
N
SC
A
L
E
:
1
/
1
6
"
=
1
'
-
0
"
LA
N
D
S
C
A
P
E
P
L
A
N
L-1
.
0
DE
S
I
G
N
E
D
B
Y
:
L
U
I
S
A
L
V
A
R
A
D
O
53821 ROSS AVENUE
LA QUINTA, CA 92253
MADISON C. C.
LOT 39A RESIDENCE
LANDSCAPE PLAN FOR
SH
E
E
T
LANDSCAPE DESIGN BY:
PO
B
O
X
2
9
1
3
IN
D
I
O
,
C
A
9
2
2
0
2
TE
L
E
P
H
O
N
E
:
(
7
6
0
)
3
4
7
-
5
0
2
2
EM
I
A
L
:
O
F
F
I
C
E
@
S
A
N
D
S
T
O
G
R
E
E
N
S
.
C
O
M
LIC
E
N
S
E
:
N
O
.
8
9
1
2
5
1
(C
-
2
7
)
,
(
C
-
6
1
/
D
1
2
)
,
(
C
-
6
1
/
D
0
6
)
,
(
C
-
5
3
)
SA
N
D
S
T
O
G
R
E
E
N
S
LA
N
D
S
A
P
E
I
N
C
.
LOT 39A
RESIDENCE
07
-
1
2
-
2
2
C
O
U
R
T
Y
A
R
D
ELECTICAL OUTLETS SUPPLIED AND
INSTALLED BY GENERAL CONTRACTOR
AT POOL EQUIPMENT
THESE DRAWINGS AND SPECIFICATIONS ARE AN INSTUMENT OF SERVICE AND REMAIN THE PROPERTY OF SANDS TO GREENS LANDSCAPE INC. THEY ARE NOT TO BE REPORDUCED OR ALTERED IN ANY WAY, NOR DISCLOSED OR ASSIGNED TO ANY THIRD PARTY WITHOUT THE WRITTEN CONSENT OF SANDS TO GREENS LANDSCAPE INC.
YARD
PO
O
L
EQ
U
I
P
M
E
N
T
EXISTING
6' WALL
EXISTING 6' WALL
COURTYARD
PROP
ERTY LINE
PROPERTY LINE
-6"
-12"
FIRE PIT BY OTHERS
FIRE PIT BY OTHERS
PROPERTY LINE
EXISTING 6' WALL
EXISTING
6' WALL
1. OUR EMPLOYEES AND SUB-CONTRACTORS WILL USE PORTABLE TOILET
LOCATED AT CONSTRUCTION SITE.
2. OUR EMPLOYEES AND SUB-CONTRACTORS WILL DIPOSE OF CONSTRUCTION
DEBRIS ON SITE.
3. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO
THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT PROPERTIES WILL
NOT BE UTILIZED. THE PUBLIC RIGHT OF WAY SHALL BE MAINTAINED IN
CLEAR CONDITION AT ALL TIMES.
SAFETY FEATURES:
* ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF
THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR THE AMERICAN
SOCIETY OF MECHANICAL ENGINEERS (ASME)
ELECTRICAL:
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE
VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26.
GOVERNMENT CODE SECTION 4216 2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL
NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR
DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED
IN AN AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TO CONTAIN SUBSURFACE
INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WITH WHITE PAINT OR
OTHER SUITABLE MARKING THE ARE TO BE EXCAVATED
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL
COMPLY WITH SECTION 114-MANDATORY REQUIREMENTS
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH
DIRECT ACCESS TO THE POOL
POOL HEATER, POOL EQUIPMENT SHALL BE INSTALLED
PER MAUNFACTURE'S RECOMMENDATIONS AND IN
ACCORDANCE WITH LOCAL REGULATIONS
LA QUINTA MUNICIPAL CODE REQUIREMENTS:
CONSTRUCTION HOURS:
OCTOBER 1ST THRU APRIL 30TH
MONDAY - FRIDAY 7:00 A.M. - 5:30 P.M.
SATURDAYS 8:00 A.M. - 5:00 P.M.
SUNDAYS NOT ALLOWED
GOVERNMENT CODE NOT ALLOWED
HOLIDAYS
SPA TO BE EQUIPPED WITH ANTI-ENTRAPMENT DEVICE (SEC. 1404 FEDERAL
SWIMMING POOL AND SPA DRAIN COVER STANDARD)
NOTE: ALL POOL HEATER INSTALLATIONS REQUIRE A CF-6R-MECH-03
FORM TO BE COMPLETED AND SIGNED BY THE INSTALLER OF
RECORD AND SUBMITTED TO THE BUILDING INSPECTOR PRIOR
TO INSPECTION APPROVAL
PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT
STADRADS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) OR
THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME). IDENTIFY A
MINIMUM 3 FEET SEPERATION BETWEEN ALL DRAINS AND NOTE HYDRAULICALLY
BALANCED
MAY 1ST THRU SEPTEMBER 30TH
MONDAY - FRIDAY 5:30 A.M. - 7:00 P.M.
SATURDAYS 8:00 A.M. - 5:00 P.M.
SUNDAYS NOT ALLOWED
GOVERNMENT CODE NOT ALLOWED
HOLIDAYS
NOTE:
1. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED
2. MASONRY EQUIPMENT WALL SHALL BE BUILT PER CITY STANDARD SPECIFICATIONS
3. ALL GFI OUTLETS WILL BE WEATHER AND TAMPER PROOF
4. ALL OUTLETS SUPPLIED BY SINGLE-PHASE, 15A AND 20A, 125V OR 240V BRANCH
CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION
5. PROVIDE 36" WORKING CLEARANCE FOR THE POOL EQUIPMENT MOTORS ARE REQUIRED
6. LED LIGHTS REQUIRE WATER BONDING.
7. POOL HEATER/POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURE INSTALLATION
SPECIFICATIONS.
8. POOL EQUIPOTENTIAL BONDING PERIMETER SURFACE PER 2019 CEC 680.26.
9. PROVIDE ADEQUATE WORKSPACE AROUND ELECTRICAL EQUIPMENT PER 2019 CEC 110.26.
10. INSTALL AN APPROVED FLOATING SAFETY POOL ALARM.
NORTH
ROSS AVENUE
GUEST
HOUSE
SLAB AND FOUNDATION
BY OTHERS
US
US
US
15' 0"
35' 0"
STEPS
RAISED BOND BEAM
+4' H X 18' L WITH 3
24" WATER SCUPPERS
STAINLES STEEL
POOL
LIGHTS
3'6" W.D.
3' 0"
POOL SPLIT MAIN DRAIN SUCTION
MINIMUM 3' APART ANTI-ENTRAPMENT
VORTEX COVERS 10" ANSI APPROVED
COPING AND BOND BEAM FINISH PORCELAIN
TILE TO SUPPLIED BY GENERAL CONTRACTOR
AND INSTALLED BY SAND TO GREENS.
0"
(2) - JANDY VARIABLE SPEED 2.7 HP
(1) - CV 460
(1) JANDY JXI 400 BTU
JANDY AUTOMATED SYSTEM
JANDY SALT SYSTEM
DATE:SIGNATURE:
A: DETERMINE THE APPROPRIATE POOL OR SPA ELEVATION
AT TIME OF LAYOUT.
B: AGREE THAT SANDS TO GREENS LANDSCAPE INC. IS NOT
RESPONSIBLE FOR UNDERGROUND CONDITIONS OR
OBJECTS, ANY DAMAGE TO CURBS, SIDEWALKS,
DRIVEWAYS, LAWNS OR OTHER ITMES IN THE AREA.
C: WET DOWN CONCRETE SHELL AT LEAST ONCE A DAILY
FOR SEVEN DAYS AFTER INSTALLED.
D: POOL EQUIPMENT LOCATION SUBJECT TO ACCEPTANCE
OF LOCAL BUILDING DEPARTMENT.
E: FILL POOL IMMEDIATELY AFTER PEBBLE OR PLATER
(FOLLOW INSTRUCTIONS).
F: OWNER APPROVES PLAN, POOL AND EQUIPMENT
LOCATIONS AND HAS READ THE RESPONISIBILITIES AND
NOTICES ABOVE.
OWNER RESPONSIBILIIES:
WATERLINE:
FINISHES
SYSTEM:
LIGHTS:
SKIMMER:
TIME CLOCK:
HEATER:
FILTER:
PUMP:
PLUMBING
POOL PERIMETER 100 LNFT
525 SQ FT POOL SURFACE AREA
35' X 15' POOL SIZE
COURTYARD
POOL SPECS
1 AUTOFILL:1
PLASTER: PEBBLE
POOL & SPA COPING
6" TILE
(4) NICHLESS LIGHTS
ENCLOSURE
PER SECTION
3109.4.1
POOL
EQUIP.
ELECTRICAL SUBPANEL
WITH POOL EQUIPMENT
DISCONNECTION (BY STG)
ENCLOSURE
PER SECTION
3109.4.1
7' 6"
7' 6"
SKIMMER
AUTOTILL
SET BACK FROM
WALL TO
WATERLINE AT 7'6"
SET BACK FROM
WALL TO
WATERLINE AT 7'6"
OVERHEAD UTILITY
SERVICE LINE NONE
EXISTING IN THIS
COMMUNITY
ELECTICAL PANEL
GAS METER
POINT OF CONNECTION
FOR GAS AND ELECTRICAL
(BY GENERAL CONTRACTOR)
2" ELECTICAL CONDUIT
AT 18" BELOWGRADE
APPROX. 235 LIN. FT.
(SUPPLIED AND INSTALLED
BY GENERAL CONTRACTOR)
2" POLY GAS LINE AT -18"
BELOW GRADE
APPROX. 230 LIN. FT.
(SUPPLIED AND INSTALLED
BY GENERAL CONTRACTOR)
19' 0"
SET BACK 19' FROM
POOL EQUIP. WALL
TO PROPERTY LINE
SET BACK 33'6"
FROM BUILDING
TO PROPERTY LINE
33' 6"
2019 CALIFORNIA RESIDENTIAL CODE
2019 CALIFORNIA BUILDING CODE
2019 CALIFORNIA MECHANICAL CODE
2019 CALIFORNIA PLUMBING CODE
2019 CALIFORNIA ELECTRICAL CODE
2019 CALIFORNIA ENERGY EFFICIENCY STANDARDS
2019 CALIFORNIA FIRE CODES
(BASED ON 2018 IRC)
(BASED ON 2018 UMC)
(BASED ON 2018 UPC) TITLE 24. PART 5
(BASED ON 2018 NEC)
(BASED ON 2018 IBC)
WATER FEATURE 8' L X 4' W
WITH RAISE WALL 3' H AND
(3) 6" SCUPPERS, FINISHED
WITH TILE, (3) LIGHT AND PUMP
-0- GROUND LEVEL
3' H X 8' L WALL WITH SCUPPERS
PR
E
P
A
R
E
D
B
Y
:
A
N
A
I
ÑIG
U
E
Z
BPOL2022-0302 - 53821 ROSS AVENUE
REVISION 1
ADDITION OF SOUTH SIDE YARD WATER FEATURE TO
SCOPE OF WORK [JHA ENGINEERING]. REAR YARD POOL
PER SEPARATE PERMIT BPOL2022-0271. 2019 CALIFORNIA
BUILDING CODES.
09/28/2022
NOT WITHIN SCOPE.
REAR YARD POOL
UNDER SEPARATE
PERMIT BPOL2022-0271.