HomeMy WebLinkAboutPGA West Legends - TR 28838 (Plans 1-6) Title 24RICK MAUVEP fir TITLE 24 ENERGY CALCULATIONS, INC. 7544 E. SADDLEHILL TRAIL, ORANGE, CA 92869 (714) 771-1507 01 Owner: Rielly Homes 23 Corporate Plaza, #245 Newport Beach, CA 92660 Designer: Bassenian/Lagoni Arch[ 2031 Orchard Drive, #1 1 Newport Beach, CA 9'9 Project: "PGA West" Plans 1,2,3,4,5, & 6 La Quinta, California Job No. 097-98085 September 17, 1998 QFVISrD',I,I/241gI& OLV(2.CWAvj�E3) AN ALL APF'!.i.'",ABLE C;')DE DATE Z� 8Y STATEMENT OF CONFORMANCE This Calculation contains all the building features and performance specifications required for compliance by the California Code of Regulations Title 24, Part 1, Administrative Requirements; Part 6, Building Energy Efficiency Standards; and portions of Title 20, Appliance Efficiency Standards. When these features are incorporated into the architectural plans the design will be in compliance with the energy efficiency standards as they apply in Climate Zone 15, using MICROPAS4 Version 4.51, a California Energy Commission approved computer performance method program. Certified Energy Analyst Rick Maurer r r NR 92-90-528 r r R 92 90-1 36 CAB EC Califomia Association of Building Energy Cortsuttarrts Prepared By: Rick Maurer Energy Plans Examiner Certificate No. RES-88-1006 and NRE-88-1052 California State License No. 502290 C20 ** SUMMARY SHEET ** Proiect: Rielly Homes -- La Quinta, CA Zone: 15 "PGA West" Plan 1 Wall Insulation: R-21 (Min. 2X6 Walls Required) Ceiling Insulation: R-38 Raised Floor Insulation: NIA Slab Edge Insulation: None Glazing Type: All glass is DUAL pane & tinted with a shade coeficient of .70 or less. (See Note #4 Below) Shading Devices: No shading devices required. Hard Surface Flooring: Total Sq. Ft. = 275 Entry: 94 Kitchen: 122 Hearth: 9 Laundry: 50 Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 58,749 BTUH For Entire House Minimum A/C SEER: 12.0 SEER A/C Tonnage: Living Zone = 3.0 Tons (Min.Sens. =24,752 @ 115°) Sleeping Zone = 3.0 Tons (Min.Sens. =21,563 @ 115°) Duct Insulation: R-6 Note(s): 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows will have vinyl frames with an NFRC U-value of .50 or less except the following, which will have metal frames and an NFRC U-value of .65 or less. #" Rear Dining Glass ** Rear Great Room Glass Rear M. Bedroom Glass French doors will be metal clad over wood with .59 default NFRC U-value. Front entry doors will have solid wood frames with .55 default NFRC U-value. 'Mt. fA, ** SUMMARY SHEET** Project: Rielly Homes -- La Quinta, CA Zone: 15 "PGA West" Plan 2 Wall Insulation: R-21 (Min. 2X6 Walls Required) Ceiling Insulation: R-38 Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL pane & tinted with a shade coeficient of .70 or less. (See Note #4 Below) Shading Devices: No shading devices required. Hard Surface Flooring: Total Sq. Ft. = 382 Entry: 120 Kitchen: 85 Hearth: 9 Laundry: 54 Nook: 114 Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 70,925 BTUH For Entire House Minimum A/C SEER: 12.0 SEER A/C Tonnage: Living Zone = 3.5 Tons (Min.Sens. =28,440 @ 115°) Sleeping Zone = 3.0 Tons (Min.Sens. =20,069 @ 115*) Casita = 2.0 Tons (Min.Sens. =7,802 @ 115°) Duct Insulation: R-6 Note(s): 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows will have vinyl frames with an NFRC U-value of .50 or less except the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Living & Dining Glass ** Rear M.Bedroom Glass Door French doors will be metal clad over wood with .59 default NFRC U-value. Front entry doors will have solid wood frames with .55 default NFRC U-value. ** SUMMARY SHEET'* Project: Rielly Homes -- La Quinta, CA Zone: 15 "PGA West" Plan 3 Wall Insulation: R-21 (Min. 2X6 Walls Required) Ceiling Insulation: R-38 (With Radiant Foil @ Roof) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL pane & tinted with a shade coeficient of .70 or less. (See Note #4 Below) Shading Devices: No shading devices required. Hard Surface Flooring: Total Sq. Ft. = 404 Entry: 92 Kitchen: 144 Hearth: 9 Laundry: 44 Nook: 115 Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 85,486 BTUH For Entire House Minimum A/C SEER: 12.0 SEER A/C Tonnage: Living Zone = 4.0 Tons (Min.Sens. =32,451 @ 115°) Sleeping Zone = 3.5 Tons (Min.Sens. =28,374 @ 115°) Casita = 2.0 Tons (Min.Sens. =7,942 @ 115°) Duct Insulation: R-8 Note(s): 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water mainlines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows will have vinyl frames with an NFRC U-value of .50 or less except the following, which will have metal frames and an NFRC U-value of .65 or less. 'Rear M.Bed. Glass Door **Great Room Glass Door ** 10x9 Great Room Windows French doors will be metal clad over wood with .59 default NFRC U-value. Front entry doors will have solid wood frames with .55 default NFRC U-value. ** SUMMARY SHEET ** Project: Rielly Homes -- La Quinta, CA Zone: 15 "PGA West" Plan 4 Wall Insulation: R-21 (Min. 2X6 Walls Required) Ceiling Insulation: R-38 Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL pane & tinted with a shade coeficient of .70 or less. (See Note #4 Below) Shading Devices: No shading devices required. Hard Surface Flooring: Total Sq. Ft. = 414 Entry: 61 Kitchen/Pantry: 121 Hearth: 9 Laundry: 48 Nook/Bar: 175 Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 92,583 BTUH For Entire House Minimum A/C SEER: 12.0 SEER A/C Tonnage: Living Zone = 5.0 Tons (Min. Sens.=39,597 @ 1150) Sleeping Zone=4.0Tons (Min.Sens. =31,127 @ 115*) Casita = 2.0 Tons (Min.Sens. =6,741 @ 115*) Duct Insulation: R-6 Note(s): 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows will have vinyl frames with an NFRC U-value of .50 or less except the following, which will have metal frames and an NFRC U-value of .65 or less. Rear Family Glass ** Rear M.Bed. Glass Door Rear Living & Dining Glass French doors will be metal clad over wood with .59 default NFRC U-value. Front entry doors will have solid wood frames with .55 default NFRC U-value. ** SUMMARY SHEET** Proiect: Rielly Homes -- La Quinta, CA Zones 15 "PGA West" Plan 5 Wail Insulation: R-21 (Min. 2X6 Walls Required) Ceiling Insulation: R-38 (With Radiant Foil @ Roof) Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL pane & tinted with a shade coeficient of .70 or less, except all the metal fenestration which will have "Low-E2" or equal and a shade coefficient of .50 or less. (See Note #4 Below) Shading Devices: No shading devices required. Hard Surface Flooring: Total Sq. Ft. = 585 Entry/Bar: 186 Kitchen: 164 Hearth: 9 Nook/Pantries: 175 Laundry: 51 Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 101,416 BTUH For Entire House Minimum A/C SEER: 12.0 SEER A/C Tonnage: Living Zone = 6.0 Tons (Min.Sens. =48,367 @ 115*) Sleeping Zone = 3.5 Tons (Min.Sens. =28,935 @ 115*) Casita = 2.0 Tons (Min.Sens. =8,323 @ 1150) Duct Insulation: R-8 Note(s): 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows will have vinyl frames with an NFRC U-value of .50 or less except the following, which will have metal frames and an NFRC U-value of .65 or less. Rear Family Glass *' 8x9 & 8x1 Family Glass Rear Living Glass "' Side Retreat Glass Door *" Nook Glass Door & 6x1 Transom Only When Door is Used. French doors will be metal clad over wood with .59 default NFRC U-value. Front entry doors will have solid wood frames with .55 default NFRC U-value. ** SUMMARY SHEET** Project: Rielly Homes -- La Quinta, CA Zone: 15 "PGA West" Plan 6 Wall Insulation: R-21 (Min. 2X6 Walls Required) Ceiling Insulation: R-38 Raised Floor Insulation: N/A Slab Edge Insulation: None Glazing Type: All glass is DUAL pane & tinted with a shade coeficient of .70 or less. (See Note #4 Below) Shading Devices: No shading devices required. Hard Surface Flooring: Total Sq. Ft. = 472 Entry: 79 Kitchen/Pantry: 210 Hearth: 9 Laundry:46 Nook: 128 Minimum Furnace AFUE: 80% AFUE Minimum Heating Capacity: 104,018 BTUH For Entire House Minimum A/C SEER: 12.0 SEER A/C Tonnage: Living Zone = 5.0 Tons (Min. Sens.=43,958 @ 115*) Sleeping Zone = 4.0 Tons (Min.Sens. =33,697 @ 115°) Casita = 2.0 Tons (Min. Sens. =7,81 9 @ 1150) Duct Insulation: R-8 Note(s): 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) All windows will have vinyl frames with an NFRC U-value of .50 or less except the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear M. Bedroom Glass ** Rear Great Room Glass **All Nook Glass French doors will be metal clad over wood with .59 default NFRC U-value. Front entry doors will have solid wood frames with .55 default NFRC U-value. MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-IR Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION IDESIGNFR_7ENF0RQEMaVT Building Envelope Measures: ' § 150(a): Minimum R-19 ceiling insulation. § 150(b): Loose fill insulation manufacturer's labeled R-Value. ` § I50(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-value in metal frame walls (does not apply to exterior mass walls). ' §150(d): Minimum R-13 raised floor insulation in framed floors: minimum R-8 in raised concrete floors. § 150(1) : Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 pernvinch. u A § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products. Exterior Doors. and Infiltrawn/Exfiltrawn Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products have label with certified U-value, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards. N/A §150(e): Installation of Fireplaces. Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: §110-13: HVAC equipment. water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or coo iine loads calculated in accordance with ASHRAE. SMACNA or ACCA. § 150(i): Setback thermostat on all appiicable heating and/or cooling systems. § 1500): Pipe and tank insulation 1. First 5 feet of pipes closest to water heater tank non -recirculating systems, insulated (R-4 or greater) 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 3. All buried or exposed piping insulated in recirculating sections of hot water systems. ✓ 4. Cooling system piping below 55' F insulated. 5. Piping insulated between heating source and indirect hot water tank. ' § 150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 601 and 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have back draft or automatic dampers. ✓ 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible. manually operated dampers. §114: Pool and Spa Heating Systems and Equipment- 1 - System is certified with 78% thermal efficiency, on -off switch. weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: / V a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces. pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non-eiectrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures: § I50(k): 40 lumens/watt or greater for general lighting to kitchens and rooms with water ctosets; and recessed ceiling fixtures are IC (insulation cover) approved. Revised March 1, 1996 MANDATORY REQUIREMENTS A) Before the building may be occupied, installation certificates for manufactured devices regulated by the Appliance Standards or Part 6 shall be posted adjacent to the building permit(s). Certificate shall: 1. Identify features required to verify compliance with the Appliance Standards and Part 6; 2. Include the statement indicating that the installed devices conform to the Appliance Standards and Part 6 and the requirements for such devices given in the plans and specifications approved by the local enforcement agency; 3. State the number of the building permit under which the construction or installation was performed. Sec. 10-103(a)(3)(A) B) The builder shall provide the building owner, manager, and the original occupants the appropriate Certificate(s) of Compliance and a list of the t ea [u res, materials, components, and mechanical devices installed in the building, and instructions on how to use them efficiently. Sec. 10-303(b)(1) C) After installing wall, ceiling, or floor insulation, the installer shall Post in a conspicuous location in the building a certificate signed by the installer stating that the installation is consistent with the plans and the requirements of Section 10-103(a) (2) (A) and conforms with the requirements of Part 6. The Certificate shall also state the manufacturer's name and material identification and the installed R-value. Sec. 10-103(a)4 0) Manufactured fenestration products shall: 1. Have a temporary label, not to be removed before inspection by the enforcement agency, listing the certified U-value and certifying that air infiltration rates do not exceed those shown in Table no. 1-E. 2. Have a permanent label listing the U-value, certifying organization, and rating procedures. S.C. Ila(a) E) Site constructed doors, skylights, and windows, including, but not limited to, field manufactured doors, skylights, and windows, shall be caulked between the door, skylights, or window and the building, and shall be Weatherstripped. EXCEPTION: Unframed glass doors and fire doors. Sec. 116(b) F) Joints and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weatherstripped, or otherwise sealed to limit infiltration and exfiltration. See. 117(a) G) All insulating material shall be installed in compliance with the flamespread rating smoke density requirements of Sections 801 and SO?- of the UBC. Sec. 118(c) H) Masonry or factory -built fireplaces shall have the following: I. Closable metal or glass doors covering the entire opening of the firebox. 2. A combustion air intake to draw air from the outside of the building directly into the firebox, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight fitting damper or combustion air control device. NOTE: Not required if the fireplace is installed over a concrete slab and will not be located on an exterior wall. 3. A flue damper with a readily accessible control. EXCEPTION: when a gas log, log lighter, or decorative gas appliance is installed in a fireplace, the flue damper shall be blocked open if required by the manufacturer's installation instructions or the State Mechanical Code. 4. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. See. 150(e) I) In Climate Zones 14 and 16 a vapor barrier shall be installed on the conditioned space side of all insulation in all exterior walls, unvented attics, and unvented crawl spaces to protect insulation from condensation. See. 150(G) J) All heating and/or cooling systems other than wood stoves shall have an automatic thermostat with a clock mechanism or other setback mechanism that shuts the system off during periods of non-use and that allows the building occupant to automatically set back the thermostat set points for at least 2 periods within 24 hours. Sec. 150(i) K) Heat pumps with supplementary electric resistance heaters shall have controls: I. That prevent supplementary heater operation when the heating load can be met by the heat pump alone; and 2. In which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher then the cut-off temperature for supplementary heating. Sec. 112(b) L) The air handling duct system shall be constructed, installed, sealed and insulated as provided in Chapter 6 of the Uniform Mechanical Code. (Must be insulated to a minimum installed level of R-4.2 or be in conditioned space). SrC. 150(m) H) All fan systems exhausting air from the building to the outside shall be provided with backdraft or automatic dampers to prevent air leakage. Sec. 150(m)5 N) Unfired hot water tanks, such as storage tanks and backup storage tanks (or solar water heating systems, shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater or have internal insulation of at least R-16 and a label on the exterior of the tank showing the insulation R-value. See. 150(j)l O) Piping, whether buried or unburied, for recirculating sections of domestic hot water systems, piping from the heating source to the storage tank for an indirect -fired domestic water heating system, cooling system piping below 55 degrees Fahrenheit, and the first five feet of hot and cold water pipes from the storage tank for non -recirculating systems shall be thermally insulated in accordance With Table No. 1-S. Sec. 150(1)2 P) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have of Cicacy of not less then 40 lumens per watt. (Fluorescent type lighting will meet this requirement). Sec. 150(k) Q) Any new low-rise residential building shall meet the following minimum requirements: I. Ceiling Insulation. The opaque portions of ceilings separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either 1 or 2 below: a. Ceilings shall be insulated between framing members with insulation resulting in an installed thermal resistance of R-19 or greater for the insulation alone. ALTERNATIVE to Section 150(a)1.: Insulation which is not penetrated by framing members may meet an R-value equivalent to installing R-19 insulation between framing members and accounting for the thermal effects of framing members. b. The weighted average U-value of ceilings shall not exceed the U-value that Would result from installing R-19 insulation between framing members in the entire ceiling and accounting for the effects of framing members. 2. lease Fill Insulation when loose fill insulation is installed, the minimum installed weight per square foot shell conform with the insulation manufacturer's in, design weight per square foot at the manufacturer's labeled R-value. 3. wall Insulation. The opaque portions of frame Walls separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either a or b below: a. Framed walls shall be insulated between framing members with insulation having an installed thermal resistance of R-13 or greater. Framed foundation walls of heated basements or heated crawl spaces shall be insulated above the adjacent outside around line With insulation having an installed thermal resistance of at least R-13. ALTERNATIVE to Section 150(c)1.: Insulation which is not penetrated by framing members may meet an R-value equivalent to installing R-13 insulation between from ing members and accounting for the thermal effects of framing members. b. The weighted average U-valve of walls shell not exceed the U-value that would result from installing R-13 insulation between framing members and accounting for the effects of framing members. 4. Raised Floor Insulation Concrete raised floors over unconditioned space shall be insulated to an installed thermal resistance of at least R-9. All other raised floors separating conditioned space from unconditioned space shall meet the requirements of either 1 or 2 below: a. Floors shall be insulated between framing members with insulation having an installed thermal resistance of R-13 or greater. b. The weighted average U-value of floor assemblies shall not exceed the U-value that would result from installing R-13 insulation between framing members and accounting for the effects of framing members. Sec. 150(a)-(d), Subchapter 7(Sec. 150) R) Systems, equipment, and building components listed below may be installed only if: 1. The manufacturer has certified that the system, equipment, or building component complies with the applicable manufacture provisions of Sections ill through 119; and 2. The system, equipment, or building component complies with the applicable installation provisions of Sections Ill through 119. Covered are: a. Appliances regulated by the Appliance Efficiency Regulations (Sec.11l). b. Other space conditioning equipment (Sec. 112). c. Pool and spa heating systems and equipment (Sec. 114). d. Gas Appliances (Sec. 115). e. Insulation (Sec. 118) Sec. 110 C$RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Project Address........ Documentation Author... Climate Zone.. ..... Compliance Method...... Rielly Homes - Plan #1 PGA West (Job #097-98085)******* La Quinta, California *v4.51* Rick Maurer ******* Rick Maurer Title 24 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 15 Date........ 11/24/98 Building Permit Plan Check / Date Field Check/ Date MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 GENERAL INFORMATION Conditioned Floor Area..... 2113 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 31.4 % of floor area Average Glazing U-value.... 0.59 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R-value R-value R-value U-value Location/Comments Wall Wood R-21 R-n/a R-21 0.059 Front Wall, Gar. Wall Left Wall, Back Wall Right Wall Roof Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door SlabEdge n/a R-0 R-n/a R-0 0.900 Exp.To Outside SlabEdge n/a R-0 R-n/a R-0 0.720 Cvd.To Outside SlabEdge n/a R-0 R-n/a R-0 0.550 Exp.To Garage SlabEdge n/a R-0 R-n/a R-0 0.500 Cvd.To Garage Wall Wood R-0 R-n/a R-0 0.293 Wall n/a R-0 R-n/a R-0 20.000 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Door Front (N) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.550 2 CEC Std.Default None Yes Wood Window Front (N) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 54.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 12.5 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 100.0 0.650 2 CEC Std.Default None Yes Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Back (S) 90.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 90.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 30.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 22.5 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 9.0 0.500 2 CEC Std.Default None Yes Vinyl THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 225 3.5 Exp.Conc.Slab (See Note) S1abOnGrade Yes 50 3.5 Exp.Conc.Slab (See Note) S1abOnGrade No 735 3.5 Covered Concrete Slab S1abOnGrade No 1103 3.5 Covered Concrete Slab InteriorHorz Yes 53 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorHorz Yes 15 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 17 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 110 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-6 LivingStat AirCond 12.00 SEER Attic R-6 LivingStat Furnace 0.800 AFUE Attic R-6 SleepingStat AirCond 12.00 SEER Attic R-6 SleepingStat Tank Type Storage WATER HEATING SYSTEMS Number in Heater Type Distribution Type System Gas Recirc/TimeTemp 1 SPECIAL FEATURES/REMARKS Tank External Energy Size Insulation Factor (gal) R-value .51 EF 75 R-12 This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 SPECIAL FEATURES/REMARKS blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Dining Glass ** Rear Great Room Glass ** Rear M.Bedroom Glass * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. CFbRTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-lR Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Rielly Homes Address. 23 Corporate P1azaDr,#245 Newport Beach, CA 92660 Phone... (949) 719-4975 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24 Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 Signed.. l/ 2 (d to COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 Project Address........ PGA West (Job 1F097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.97 3.25 -0.28 Space Cooling.......... 32.61 27.39 5.22 Water Heating.......... 11.48 11.32 0.16 North Total 47.06 41.96 5.10 Space Heating.......... 2.97 3.55 -0.58 Space Cooling.......... 32.61 30.29 2.32 Water Heating.......... 11.48 11.32 0.16 East Total 47.06 45.16 1.90 Space Heating.......... 2.97 3.35 -0.38 Space Cooling.......... 32.61 27.60 5.01 Water Heating.......... 11.48 11.32 0.16 South Total 47.06 42.27 4.79 Space Heating.......... 2.97 2.88 0.09 Space Cooling.......... 32.61 30.51 2.10 Water Heating.......... 11.48 11.32 0.16 West Total 47.06 44.71 2.35 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 2113 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-value.... Average Ceiling Height..... Floor Area Zone Type (sf) LIVINGI Living SLEEPING Sleeping Surface LIVINGI 1 Wall 5 Wall 7 Wall 9 Roof SLEEPING 2 Wall 3 Wall 4 Wall 6 Wall 8 Wall 10 Roof 11 Door Surface 24203 cf 2113 sf 2113 sf 2113 sf 31.4 % of floor area 0.59 Btu/hr-sf-F 11.5 ft BUILDING ZONE INFORMATION # of Vent Special Volume Dwell Cond- Thermostat Height Vent Area (cf) Units itioned Type (ft) (sf) 960 11520 1.00 Yes LivingStat 2.0 n/a 1153 12683 0.00 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ (sf) value R-val Azm Tilt Gains Reference Comments 232 0.059 21 0 90 Yes None Front Wall 172 0.059 21 180 90 Yes None Back Wall 108 0.059 21 270 90 Yes None Right Wall 960 0.025 38 n/a 0 Yes None Vented Attic 212 0.059 21 0 90 Yes None Front Wall 202 0.059 21 0 90 No None Gar. Wall 515 0.059 21 90 90 Yes None Left Wall 263 0.059 21 180 90 Yes None Back Wall 391 0.059 21 270 90 Yes None Right Wall 1153 0.025 38 n/a 0 Yes None Vented Attic 21 0.330 0 0 90 No None Garage Door PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments LIVINGI 12 S1abEdge 13 S1abEdge SLEEPING 14 S1abEdge 15 S1abEdge 16 SlabEdge 23 0.900 R-0 53 0.720 R-0 145 0.720 R-0 6 0.550 R-0 14 0.500 R-0 No Exp.To Outside No Cvd.To Outside No Cvd.To Outside No Exp.To Garage No Cvd.To Garage COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description LIVINGI 2 Window 8.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 3 Door 48.0 2 Wood Slider 0.550 0 90 0.70 0.78 CEC Std.Default 4 Window 12.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 5 Window 54.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 11 Door 100.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 12 Window 90.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 13 Window 90.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 16 Window 12.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default SLEEPING 1 Door 48.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 6 Window 8.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 7 Window 8.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 8 Window 8.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 9 Window 12.5 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 10 Door 80.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 14 Window 30.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 15 Window 5.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 17 Window 12.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 18 Window 22.5 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 19 Window 6.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 20 Window 9.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght LIVINGI 2 Window 8.0 4.0 n/a 7.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 48.0 8.0 n/a 7.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 12.0 2.0 n/a 7.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 54.0 6.0 n/a 7.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Door 100.0 10. n/a 13. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 90.0 9.0 n/a 13. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 90.0 9.0 n/a 13. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 12.0 2.0 n/a 17.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a SLEEPING 1 Door 48.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 8.0 2.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 8.0 4.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 8.0 4.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 12.5 5.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 10 Door 80.0 10. n/a 10. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 30.0 5.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 5.0 2.0 n/a 1.0 8.5 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 12.0 2.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 22.5 5.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 6.0 3.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 20 Window 9.0 2.0 n/a 1.0 7.0 n/a n/a n/a n/a n/a n/a n/a n/a INTER -ZONE SURFACES Area Insul Form 3 Surface (sf) U-value R-val Reference LIVINGI/SLEEPING 1 Wall 440 0.293 R-0 2 Wall 40 20.000 R-0 Mass Type LIVINGI 1 S1abOnGrade 3 S1abOnGrade 5 InteriorHorz 7 InteriorVert SLEEPING 2 S1abOnGrade 4 S1abOnGrade 6 InteriorHorz 8 InteriorVert NONE NONE THERMAL MASS Area Thick Heat Conduct- Surface (sf) (in) Cap ivity R-value Location/Comments Location/Comments 225 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 735 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 53 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 17 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh 50 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 1103 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 15 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 110 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct System Type Efficiency Location LIVINGI Duct Duct R-value Efficiency Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 SLEEPING Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value 1 Storage Gas Recirc/TimeTemp 1 .51 75 R-12 COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Rielly Homes - Plan #1 Date........ 11/24/98 MICR0PAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Dining Glass ** Rear Great Room Glass ** Rear M.Bedroom Glass * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. HVAC SIZING Page 1 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 GENERAL INFORMATION FloorArea ................. Volume.. .... ............ Front Orientation.......... Sizing Location............ Latitude... ..... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2113 sf 24203 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 0 deg (N) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 13563 6893 Glazing Conduction ............... 14740 13189 Glazing Solar .................... n/a 8437 Infiltration ..................... 12780 8458 Internal Gain .................... n/a 2550 Ducts ............................ 4108 3953 Sensible Load .................... 45192 43479 Latent Load ...................... n/a 13044 Minimum Total Load 45192 56523 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HV'AC SIZING Page 2 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 960 sf Volume........................... 11520 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 4297 2257 Glazing Conduction ............... 9553 8548 Glazing Solar .................... n/a 3630 Infiltration ..................... 6083 4026 Internal Gain .................... n/a 2550 Ducts ............................ 1993 2101 Sensible Load .................... 21926 23111 Latent Load ...................... n/a 6933 Minimum Zone Load 21926 30044 ZONE 'SLEEPING' Floor Area ....................... 1153 sf Volume ........................... 12683 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9266 4636 Glazing Conduction ............... 5187 4641 Glazing Solar .................... n/a 4808 Infiltration ..................... 6697 4432 InternalGain .................... n/a 0 Ducts ............................ 2115 1852 Sensible Load .................... 23266 20369 Latent Load ...................... n/a 6111 Minimum Zone Load 23266 26479 HVAC SIZING Page 3 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 GENERAL INFORMATION FloorArea ................. Volume.. .... ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2113 sf 24203 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 90 deg (E) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 13563 6893 Glazing Conduction ............... 14740 13189 Glazing Solar .................... n/a 10945 Infiltration ..................... 12780 8458 Internal Gain .................... n/a 2550 Ducts ............................ 4108 4203 Sensible Load .................... 45192 46238 Latent Load ...................... n/a 13871 Minimum Total Load 45192 60109 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 4 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 V4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 960 sf Volume ........................... 11520 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 4297 2257 Glazing Conduction ............... 9553 8548 Glazing Solar .................... n/a 5122 Infiltration ..................... 6083 4026 Internal Gain .................... n/a 2550 Ducts ............................ 1993 2250 Sensible Load .................... 21926 24752 Latent Load ...................... n/a 7426 Minimum Zone Load 21926 ZONE 'SLEEPING' Floor Area ....................... 1153 sf Volume ........................... 12683 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Heating (Btuh) 32177 Cooling (Btuh) 9266 4636 5187 4641 n/a 5823 6697 4432 n/a 0 2115 1953 23266 21486 n/a 6446 Minimum Zone Load 23266 27932 HVAC SIZING Page 5 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2113 sf 24203 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 13563 6893 Glazing Conduction ............... 14740 13189 Glazing Solar .................... n/a 8455 Infiltration ..................... 12780 8458 Internal Gain .................... n/a 2550 Ducts ............................ 4108 3954 Sensible Load .................... 45192 43499 Latent Load ...................... n/a 13050 Minimum Total Load 45192 56548 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 6 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY11TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 960 sf Volume ........................... 11520 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... LatentLoad ...................... Minimum Zone Load ZONE 'SLEEPING' Heating Cooling (Btuh) (Btuh) 4297 2257 9553 8548 n/a 3630 6083 4026 n/a 2550 1993 2101 21926 23111 n/a 6933 21926 30044 Floor Area ....................... 1153 sf Volume ........................... 12683 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9266 Glazing Conduction ............... 5187 Glazing Solar .................... n/a Infiltration ..................... 6697 InternalGain .................... n/a Ducts ............................ 2115 Sensible Load .................... 23266 Latent Load ...................... n/a Minimum Zone Load 23266 4636 4641 4825 4432 0 1853 20388 6116 26505 HVAC SIZING Page 7 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 GENERAL INFORMATION Floor Area ................. Volume.. . ........... Front Orientation.......... Sizing Location............ Latitude... ......... Winter Outside Design..,.... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range.. ...... Interior Shading Used Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2113 sf 24203 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 13563 6893 Glazing Conduction ............... 14740 13189 Glazing Solar .................... n/a 11015 Infiltration ..................... 12780 8458 Internal Gain .................... n/a 2550 Ducts ............................ 4108 4210 Sensible Load .................... 45192 46315 Latent Load ...................... n/a 13894 Minimum Total Load 45192 60209 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... Rielly Homes - Plan #1 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYIITS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #1 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 960 sf Volume ........................... 11520 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 4297 2257 Glazing Conduction ............... 9553 8548 Glazing Solar .................... n/a 5122 Infiltration ..................... 6083 4026 Internal Gain .................... n/a 2550 Ducts ............................ 1993 2250 Sensible Load .................... 21926 24752 Latent Load ...................... n/a 7426 Minimum Zone Load 21926 32177 ZONE 'SLEEPING' Floor Area ....................... 1153 sf Volume ........................... 12683 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 9266 4636 Glazing Conduction ............... 5187 4641 Glazing Solar .................... n/a 5893 Infiltration ..................... 6697 4432 InternalGain .................... n/a 0 Ducts ............................ 2115 1960 Sensible Load .................... 23266 21563 Latent Load ...................... n/a 6469 Minimum Zone Load 23266 28032 CVATIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 Project Address........ PGA West (Job 1F097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field C ec Da e Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 GENERAL INFORMATION Conditioned Floor Area..... 2483 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ....... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 31.4 % of floor area Average Glazing U-value.... 0.56 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R-value R-value R-value U-value Location/Comments Wall Wood R-21 R-n/a R-21 0.059 Front Wall, Gar. Wall Left Wall, Back Wall Right Wall Roof Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door S1abEdge n/a R-0 R-n/a R-0 0.900 Exp.To Outside S1abEdge n/a R-0 R-n/a R-0 0.720 Cvd.To Outside S1abEdge n/a R-0 R-n/a R-0 0.550 Exp.To Garage S1abEdge n/a R-0 R-n/a R-0 0.500 Cvd.To Garage Wall Wood R-0 R-n/a R-0 0.293 Wall n/a R-0 R-n/a R-0 20.000 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (N) 15.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.550 2 CEC Std.Default None Yes Wood Window Left (E) 40.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-lR Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 Orientation Area U- (sf) Value FENESTRATION # of Interior Over- Pan- Shading/ Exterior hang/ Framing es Description Shading Fins Type Window Left (E) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 90.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 100.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 40.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Door Right (W) 24.0 0.590 2 CEC Std.Default None Yes Wood Window Right (W) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 4.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 8.0 0.500 2 CEC Std.Default None Yes Vinyl THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments SlabOnGrade Yes 328 3.5 Exp.Conc.Slab (See Note) SlabOnGrade Yes 54 3.5 Exp.Conc.Slab (See Note) SlabOnGrade No 726 3.5 Covered Concrete Slab SlabOnGrade No 317 3.5 Covered Concrete Slab SlabOnGrade No 1058 3.5 Covered Concrete Slab InteriorHorz Yes 59 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorHorz Yes 14 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 18 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 55 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 111 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-6 LivingStat AirCond 12.00 SEER Attic R-6 LivingStat Furnace 0.800 AFUE Attic R-6 LivingStat AirCond 12.00 SEER Attic R-6 LivingStat Furnace 0.800 AFUE Attic R-6 SleepingStat AirCond 12.00 SEER Attic R-6 SleepingStat C]rATIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value Storage Gas Recirc/TimeTemp 1 .51 EF 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen ** Nook 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Two 8x8 Nook Windows ** Rear Living & Dining Glass ** Rear M.Bedroom Glass Door * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Rielly Homes Address. 23 Corporate P1azaDr,#245 Newport Beach, CA 92660 Phone... (949) 719-4975 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24 Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 Signed. . (dater COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Da e Climate Zone. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.53 3.78 -0.25 Space Cooling.......... 33.79 30.20 3.59 Water Heating.......... 10.49 10.34 0.15 North Total 47.81 44.32 3.49 Space Heating.......... 3.53 3.52 0.01 Space Cooling.......... 33.79 32.48 1.31 Water Heating.......... 10.49 10.34 0.15 East Total 47.81 46.34 1.47 Space Heating.......... 3.53 3.59 -0.06 Space Cooling.......... 33.79 30.01 3.78 Water Heating.......... 10.49 10.34 0.15 South Total 47.81 43.94 3.87 Space Heating.......... 3.53 3.52 0.01 Space Cooling.......... 33.79 31.99 1.80 Water Heating.......... 10.49 10.34 0.15 West Total 47.81 45.85 1.96 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 2483 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 C014PUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 Conditioned Volume......... 28050 cf Footprint Area ............. 2483 sf Ground Floor Area.......... 2483 sf Slab -On -Grade Area......... 2483 sf Glazing Percentage......... 31.4 % of floor area Average Glazing U-value.... 0.56 Btu/hr-sf-F Average Ceiling Height..... 11.3 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) LIVINGI Living 1054 12648 0.77 Yes LivingStat 2.0 n/a LIVING2 Living 317 3170 0.23 Yes LivingStat 2.0 n/a SLEEPING Sleeping 1112 12232 0.00 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments LIVINGI 1 Wall 244 0.059 21 0 90 Yes None Front Wall 5 Wall 200 0.059 21 90 90 Yes None Left Wall 8 Wall 272 0.059 21 180 90 Yes None Back Wall 11 Wall 31 0.059 21 270 90 Yes None Right Wall 14 Roof 1054 0.025 38 n/a 0 Yes None Vented Attic LIVING2 2 Wall 217 0.059 21 0 90 Yes None Front Wall 6 Wall 158 0.059 21 90 90 Yes None Left Wall 9 Wall 192 0.059 21 180 90 Yes None Back Wall 12 Wall 146 0.059 21 270 90 Yes None Right Wall 15 Roof 317 0.025 38 n/a 0 Yes None Vented Attic SLEEPING 3 Wall 180 0.059 21 0 90 Yes None Front Wall 4 Wall 199 0.059 21 0 90 No None Gar. Wall 7 Wall 302 0.059 21 90 90 Yes None Left Wall 10 Wall 153 0.059 21 180 90 Yes None Back Wall 13 Wall 510 0.059 21 270 90 Yes None Right Wall 16 Roof 1112 0.025 38 n/a 0 Yes None Vented Attic 17 Door 21 0.330 0 0 90 No None Garage Door COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVINGI 18 S1abEdge 51 0.900 R-0 No Exp.To Outside 20 S1abEdge 50 0.720 R-0 No Cvd.To Outside LIVING2 21 S1abEdge 82 0.720 R-0 No Cvd.To Outside SLEEPING 19 S1abEdge 10 0.900 R-0 No Exp.To Outside 22 S1abEdge 119 0.720 R-0 No Cvd.To Outside 23 S1abEdge 6 0.550 R-0 No Exp.To Garage 24 SlabEdge 14 0.500 R-0 No Cvd.To Garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description LIVINGI 4 Window 36.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 5 Window 12.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 6 Window 12.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 7 Window 18.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 8 Door 48.0 2 Wood Slider 0.550 0 90 0.70 0.78 CEC Std.Default 9 Window 40.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 10 Window 8.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 11 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 18 Window 90.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 19 Door 100.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 20 Window 8.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 21 Window 40.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 23 Door 24.0 2 Wood Slider 0.590 270 90 0.70 0.78 CEC Std.Default 24 Window 5.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default LIVING2 1 Window 15.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 2 Window 8.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 22 Door 48.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default SLEEPING 3 Door 48.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 12 Window 8.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 13 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 14 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 15 Window 12.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 16 Window 36.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 17 Door 80.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 25 Window 12.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 26 Window 4.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 27 Window 24.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 28 Window 8.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Rielly Homes - Plan 42 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght LIVINGI 4 Window 36.0 6.0 n/a 5.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 12.0 2.0 n/a 5.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 12.0 2.0 n/a 5.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 18.0 6.0 n/a 5.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 48.0 8.0 n/a 5.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 40.0 5.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 8.0 1.0 n/a 1.0 7.5 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 12.0 2.0 n/a 1.0 0.7 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 90.0 9.0 n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 19 Door 100.0 10. n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 8.0 1.0 n/a 1.0 7.5 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 40.0 5.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 23 Door 24.0 8.0 n/a 20. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 5.0 1.7 n/a 20. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a LIVING2 1 Window 15.0 5.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 8.0 4.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 22 Door 48.0 8.0 n/a 1.0 4.5 n/a n/a n/a n/a n/a n/a n/a n/a SLEEPING 3 Door 48.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 8.0 2.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 12.0 2.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 12.0 4.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 12.0 2.0 n/a 15. 6.0 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 36.0 6.0 n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 17 Door 80.0 10. n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 12.0 2.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 4.0 2.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 24.0 6.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 8.0 2.0 n/a 1.0 9.0 n/a n/a n/a n/a n/a n/a n/a n/a INTER -ZONE SURFACES Area Insul Form 3 Surface (sf) U-value R-val Reference Location/Comments LIVINGI/SLEEPING 1 Wall 480 0.293 R-0 NONE 2 Wall 30 20.000 R-0 NONE C09PUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY12TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R-value Location/Comments LIVINGI 1 S1abOnGrade 328 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 3 S1abOnGrade 726 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 6 InteriorHorz 59 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 8 InteriorVert 18 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh LIVING2 4 S1abOnGrade 317 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 9 InteriorVert 55 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh SLEEPING 2 S1abOnGrade 54 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 5 SlabOnGrade 1058 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 7 InteriorHorz 14 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 10 InteriorVert ill 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVINGI Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 LIVING2 Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 SLEEPING Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value 1 Storage Gas Recirc/TimeTemp 1 .51 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a COAPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... Rielly Homes - Plan #2 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 .Run -PGA West - Plan #2 SPECIAL FEATURES/REMARKS hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen ** Nook 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Two 8x8 Nook Windows ** Rear Living & Dining Glass ** Rear M.Bedroom Glass Door * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. HVAC SIZING Page 1 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field -Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... SizingLocation............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2483 sf 28050 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... LatentLoad ...................... 0 deg (N) Heating Cooling (Btuh) (Btuh) 18254 8749 16532 14792 n/a 11660 14812 9802 n/a 2171 4960 4717 54558 51890 n/a 15567 Minimum Total Load 54558 67457 7.I,3 70/915'rniN,H11v,4rV Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVXC SIZING Page 2 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY12TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1054 sf Volume ........................... 12648 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5788 2833 Glazing Conduction ............... 9863 8825 Glazing Solar .................... n/a 5965 Infiltration ..................... 6679 4420 Internal Gain .................... n/a 1964 Ducts ............................ 2233 2401 Sensible Load .................... 24563 26407 Latent Load ...................... n/a 7922 Minimum Zone Load 24563 34329 ZONE 'LIVING2' Floor Area ....................... 317 sf Volume ........................... 3170 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 4143 1791 Glazing Conduction ............... 1349 1207 Glazing Solar .................... n/a 1019 Infiltration ..................... 1674 1108 Internal Gain .................... n/a 207 Ducts............................ 717 533 Sensible Load .................... 7883 5866 Latent Load ...................... n/a 1760 Minimum Zone Load 7883 7625 HVAC SIZING Page 3 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY12TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 ZONE 'SLEEPING' Floor Area ....................... 1112 sf Volume ........................... 12232 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 8322 4124 Glazing Conduction ............... 5320 4760 Glazing Solar .................... n/a 4676 Infiltration ..................... 6459 4274 InternalGain .................... n/a 0 Ducts ............................ 2010 1783 Sensible Load .................... 22111 19617 Latent Load ...................... n/a 5885 Minimum Zone Load 22111 25503 HVAC SIZING Page 4 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 GENERAL INFORMATION FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location............ Latitude... ..... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange.. ..... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 2483 sf 28050 cf Front Facing 90 deg (E) LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 18254 8749 Glazing Conduction ............... 16532 14792 Glazing Solar .................... n/a 14448 Infiltration ..................... 14812 9802 Internal Gain .................... n/a 2171 Ducts ............................ 4960 4996 Sensible Load .................... 54558 54957 Latent Load ...................... n/a 16487 Minimum Total Load 54558 71444 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 5 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 1054 sf Volume ........................... 12648 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Zone Load ZONE 'LIVING2' Heating Cooling (Btuh) (Btuh) 5788 2833 9863 8825 n/a 7813 6679 4420 n/a 1964 2233 2585 24563 28440 n/a 8532 24563 36972 Floor Area ....................... 317 sf Volume ........................... 3170 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 4143 Glazing Conduction ............... 1349 GlazingSolar .................... n/a Infiltration ..................... 1674 InternalGain .................... n/a Ducts............................ 717 Sensible Load .................... 7883 LatentLoad ...................... n/a Minimum Zone Load 7883 1791 1207 2780 1108 207 709 7802 2341 10143 HVAC SIZING Page 6 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY12TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 ZONE 'SLEEPING' Floor Area ....................... 1112 sf Volume ........................... 12232 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 8322 4124 Glazing Conduction ............... 5320 4760 Glazing Solar .................... n/a 3855 Infiltration ..................... 6459 4274 Internal Gain .................... n/a 0 Ducts ............................ 2010 1701 Sensible Load .................... 22111 18715 Latent Load ...................... n/a 5615 Minimum Zone Load 22111 24330 HVP,C SIZING Page 7 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 2483 sf 28050 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Description (Btuh) 180 deg (S) Cooling (Btuh) Opaque Conduction and Solar...... 18254 8749 Glazing Conduction ............... 16532 14792 Glazing Solar .................... n/a 11441 Infiltration ..................... 14812 9802 Internal Gain .................... n/a 2171 Ducts ............................ 4960 4695 Sensible Load .................... 54558 51650 Latent Load ...................... n/a 15495 Minimum Total Load 54558 67145 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY12TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 1054 sf Volume ........................... 12648 cf Heating Description (Btuh) Opaque Conduction and Solar...... 5788 Glazing Conduction ............... 9863 GlazingSolar .................... n/a Infiltration ..................... 6679 InternalGain .................... n/a Ducts............................ 2233 Sensible Load .................... 24563 LatentLoad ...................... n/a Minimum Zone Load 24563 ZONE 'LIVING2' Floor Area ....................... 317 sf Volume ........................... 3170 cf Heating Description (Btuh) Opaque Conduction and Solar...... 4143 Glazing Conduction ............... 1349 GlazingSolar .................... n/a Infiltration ..................... 1674 Internal Gain .................... n/a Ducts............................ 717 Sensible Load .................... 7883 Latent Load ...................... n/a Minimum Zone Load 7883 Cooling (Btuh) 2833 8825 5712 4420 1964 2375 26129 7839 33968 Cooling (Btuh) 1791 1207 643 1108 207 496 5452 1636 7087 HVAC SIZING Page 9 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY22TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 ZONE 'SLEEPING' Floor Area ....................... 1112 sf Volume ........................... 12232 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 8322 4124 Glazing Conduction ............... 5320 4760 Glazing Solar .................... n/a 5086 Infiltration ..................... 6459 4274 Internal Gain .................... n/a 0 Ducts ............................ 2010 1824 Sensible Load .................... 22111 20069 Latent Load ...................... n/a 6021 Minimum Zone Load 22111 26090 HVAC SIZING Page 10 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY22TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 GENERAL INFORMATION Floor Area ................. 2483 sf Volume.. ............ 28050 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ LA QUINTA Latitude... ..... ....... 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range........ ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 18254 8749 Glazing Conduction ............... 16532 14792 Glazing Solar .................... n/a 14310 Infiltration ..................... 14812 9802 Internal Gain .................... n/a 2171 Ducts ............................ 4960 4982 Sensible Load .................... 54558 54805 Latent Load ...................... n/a 16442 Minimum Total Load 54558 71247 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 11 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1054 sf Volume ........................... 12648 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5788 2833 Glazing Conduction ............... 9863 8825 Glazing Solar .................... n/a 7560 Infiltration ..................... 6679 4420 Internal Gain .................... n/a 1964 Ducts ............................ 2233 2560 Sensible Load .................... 24563 28162 Latent Load ...................... n/a 8448 Minimum Zone Load 24563 36610 ZONE 'LIVING2' Floor Area ....................... 317 sf Volume ........................... 3170 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 4143 1791 Glazing Conduction ............... 1349 1207 Glazing Solar .................... n/a 2780 Infiltration ..................... 1674 1108 Internal Gain .................... n/a 207 Ducts............................ 717 709 Sensible Load .................... 7883 7802 Latent Load ...................... n/a 2341 Minimum Zone Load 7883 10143 u HV'AC SIZING Page 12 HVAC Project Title.......... Rielly Homes - Plan #2 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI2TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #2 ZONE 'SLEEPING' Floor Area ....................... 1112 sf Volume ........................... 12232 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 8322 4124 Glazing Conduction ............... 5320 4760 Glazing Solar .................... n/a 3970 Infiltration ..................... 6459 4274 InternalGain .................... n/a 0 Ducts ............................ 2010 1713 Sensible Load .................... 22111 18842 Latent Load ...................... n/a 5652 Minimum Zone Load 22111 24494 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Project Address........ Documentation Author... Climate Zone.. ..... Compliance Method...... Rielly Homes - Plan #3 PGA West (Job #097-98085)******* La Quinta, California *v4.51* Rick Maurer ******* Rick Maurer Title 24 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 15 Page 1 CF-1R Date........ 11/24/98 Building Permit Plan Check / Date Field C ec Da e MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 GENERAL INFORMATION Conditioned Floor Area..... 2818 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 36 % of floor area Average Glazing U-value.... 0.56 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R-value R-value R-value U-value Location/Comments Wall Wood R-21 R-n/a R-21 0.059 Front Wall, Gar. Wall Left Wall, Back Wall Right Wall RoofRadiant Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door S1abEdge n/a R-0 R-n/a R-0 0.900 Exp.To Outside S1abEdge n/a R-0 R-n/a R-0 0.720 Cvd.To Outside S1abEdge n/a R-0 R-n/a R-0 0.550 Exp.To Garage S1abEdge n/a R-0 R-n/a R-0 0.500 Cvd.To Garage Wall Wood R-0 R-n/a R-0 0.293 Wall n/a R-0 R-n/a R-0 20.000 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (N) 15.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 15.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 64.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.550 2 CEC Std.Default None Yes Wood Window Left (E) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Door Left (E) 100.0 0.650 2 CEC Std.Default None Yes Metal Door Left (E) 24.0 0.590 2 CEC Std.Default None Yes Wood CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY13TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Left (E) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 54.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 50.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 30.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 8.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 100.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 90.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 100.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 64.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 16.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Door Right (W) 48.0 0.500 2 CEC Std.Default None Yes Vinyl THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments SlabOnGrade Yes 360 3.5 Exp.Conc.Slab (See Note) SlabOnGrade Yes 44 3.5 Exp.Conc.Slab (See Note) SlabOnGrade No 625 3.5 Covered Concrete Slab SlabOnGrade No 323 3.5 Covered Concrete Slab SlabOnGrade No 1466 3.5 Covered Concrete Slab InteriorHorz Yes 71 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorHorz Yes 15 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 18 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 55 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 142 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-8 LivingStat AirCond 12.00 SEER Attic R-8 LivingStat Furnace 0.800 AFUE Attic R-8 LivingStat AirCond 12.00 SEER Attic R-8 LivingStat Furnace 0.800 AFUE Attic R-8 SleepingStat AirCond 12.00 SEER Attic R-8 SleepingStat CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-lR Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM CF-lR User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 WATER HEATING SYSTEMS Number in Energy Tank Type Heater Type Distribution Type System Factor Storage Gas Recirc/TimeTemp 1 .51 EF SPECIAL FEATURES/REMARKS Tank External Size Insulation (gal) R-value 75 R-12 This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen ** Nook 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an.NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear M.Bedroom Glass Door ** Great Room Glass Doors ** 10x9 Great Room Windows * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Rielly Homes Address. 23 Corporate P1azaDr,#245 Newport Beach, CA 92660 Phone... (949) 719-4975 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24 Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 Signed.. /,.I? (d to COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.85 3.31 0.54 Space Cooling.......... 34.49 32.84 1.65 Water Heating.......... 9.27 9.14 0.13 North Total 47.61 45.29 2.32 Space Heating.......... 3.85 3.61 0.24 Space Cooling.......... 34.49 34.54 -0.05 Water Heating.......... 9.27 9.14 0.13 East Total 47.61 47.29 0.32 Space Heating.......... 3.85 4.24 -0.39 Space Cooling.......... 34.49 32.24 2.25 Water Heating.......... 9.27 9.14 0.13 South Total 47.61 45.62 1.99 Space Heating.......... 3.85 3.70 0.15 Space Cooling.......... 34.49 33.89 0.60 Water Heating.......... 9.27 9.14 0.13 West Total 47.61 46.73 0.88 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 2818 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-value.... Average Ceiling Height..... 31660 cf 2818 sf 2818 sf 2818 sf 36 % of floor area 0.56 Btu/hr-sf-F 11.2 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) LIVINGI Living 985 11820 0.75 Yes LivingStat 2.0 n/a LIVING2 Living 323 3230 0.25 Yes LivingStat 2.0 n/a SLEEPING Sleeping 1510 16610 0.00 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments LIVINGI 1 Wall 334 0.059 21 0 90 Yes None Front Wall 5 Wall 197 0.059 21 90 90 Yes None Left Wall 8 Wall 244 0.059 21 180 90 Yes None Back Wall 11.Wall 96 0.059 21 270 90 Yes None Right Wall 15 RoofRadiant 985 0.025 38 n/a 0 Yes None Vented Attic LIVING2 2 Wall 190 0.059 21 0 90 Yes None Front Wall 6 Wall 144 0.059 21 90 90 Yes None Left Wall 9 Wall 132 0.059 21 180 90 Yes None Back Wall 12 Wall 138 0.059 21 270 90 Yes None Right Wall 16 RoofRadiant 323 0.025 38 n/a 0 Yes None Vented Attic SLEEPING 3 Wall 275 0.059 21 0 90 Yes None Front Wall 4 Wall 177 0.059 21 0 90 No None Gar. Wall 7 Wall 369 0.059 21 90 90 Yes None Left Wall 10 Wall 319 0.059 21 180 90 Yes None Back Wall 13 Wall 480 0.059 21 270 90 Yes None Right Wall 14 Wall 242 0.059 21 270 90 No None Gar. Wall 17 RoofRadiant 1510 0.025 38 n/a 0 Yes None Vented Attic 18 Door 21 0.330 0 0 90 No None Garage Door COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVINGI 19 S1abEdge 20 S1abEdge LIVING2 21 S1abEdge SLEEPING 22 S1abEdge 23 S1abEdge 24 SlabEdge 33 0.900 R-0 91 0.720 R-0 74 0.720 R-0 No Exp.To Outside No Cvd.To Outside No Cvd.To Outside 166 0.720 R-0 No Cvd.To Outside 8 0.550 R-0 No Exp.To Garage 32 0.500 R-0 No Cvd.To Garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description LIVINGI 3 Door 64.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 4 Window 8.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 5 Window 24.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 6 Window 8.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 7 Window 12.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 8 Door 48.0 2 Wood Slider 0.550 0 90 0.70 0.78 CEC Std.Default 10 Door 100.0 2 Metal Slider 0.650 90 90 0.70 0.78 CEC Std.Default 11 Door 24.0 2 Wood Slider 0.590 90 90 0.70 0.78 CEC Std.Default 12 Window 5.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 13 Window 54.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 21 Window 90.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 22 Door 100.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 23 Door 64.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default LIVING2 1 Window 15.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 2 Window 15.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 9 Window 6.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 24 Door 48.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default SLEEPING 14 Window 50.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 15 Window 30.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 16 Window 8.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 17 Window 6.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 18 Door 100.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 19 Window 12.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 20 Window 36.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 25 Window 16.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 26 Window 6.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 27 Window 18.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 28 Door 48.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght LIVINGI 3 Door 64.0 8.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 8.0 2.0 n/a 1.0 0.7 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 24.0 6.0 n/a 7.5 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 8.0 2.0 n/a 7.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 12.0 2.0 n/a 7.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 48.0 8.0 n/a 7.5 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 10 Door 100.0 10. n/a 12.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Door 24.0 8.0 n/a 12.5 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 5.0 1.7 n/a 12.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 54.0 6.0 n/a 1.0 4.5 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 90.0 9.0 n/a 12. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 22 Door 100.0 10. n/a 12. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 23 Door 64.0 8.0 n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a LIVING2 1 Window 15.0 5.0 n/a 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 15.0 5.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 6.0 3.0 n/a 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 24 Door 48.0 8.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a SLEEPING 14 Window 50.0 8.0 n/a 1.0 5.0 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 30.0 5.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 8.0 2.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 17.Window 6.0 3.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Door 100.0 10. n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 12.0 2.0 n/a 1.0 7.5 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 36.0 6.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 16.0 2.0 n/a 1.0 4.5 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 6.0 3.0 n/a 1.0 9.5 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 18.0 3.0 n/a 1.0 6.5 n/a n/a n/a n/a n/a n/a n/a n/a 28 Door 48.0 8.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a INTER -ZONE SURFACES Area Insul Form 3 Surface (sf) U-value R-val Reference Location/Comments LIVINGI/SLEEPING 1 Wall 240 0.293 R-0 NONE 2 Wall 32 20.000 R-0 NONE COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R-value Location/Comments LIVINGI 1 SlabOnGrade 360 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 3 SlabOnGrade 625 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 6 InteriorHorz 71 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 8 InteriorVert 18 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh LIVING2 4 SlabOnGrade 323 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 9 InteriorVert 55 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh SLEEPING 2 SlabOnGrade 44 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 5 SlabOnGrade 1466 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 7 InteriorHorz 15 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 10 InteriorVert 142 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVINGI Furnace 0.800 AFUE Attic R-8 0.850 Aircond 12.00 SEER Attic R-8 0.840 LIVING2 Furnace 0.800 AFUE Attic R-8 0.850 AirCond 12.00 SEER Attic R-8 0.840 SLEEPING Furnace 0.800 AFUE Attic R-8 0.850 AirCond 12.00 SEER Attic R-8 0.840 WATER HEATING SYSTEMS Number in Tank Type Heater Type Distribution Type System 1 Storage Gas Recirc/TimeTemp 1 SPECIAL FEATURES/REMARKS Tank Energy Size Factor (gal) .51 75 External Insulation R-value R-12 This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a COMPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... Rielly Homes - Plan #3 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 SPECIAL FEATURES/REMARKS hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen ** Nook 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear M.Bedroom Glass Door ** Great Room Glass Doors ** lOx9 Great Room Windows * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. HVAC SIZING Page 1 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 GENERAL INFORMATION FloorArea ................. Volume.. .. ........... Front Orientation.......... Sizing Location............ Latitude... .... ....... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2818 sf 31660 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 0 deg (N) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21382 8063 Glazing Conduction ............... 21681 19399 Glazing Solar .................... n/a 17447 Infiltration ..................... 16718 11064 Internal Gain .................... n/a 2475 Ducts ............................ 5978 5845 Sensible Load .................... 65759 64293 Latent Load ...................... n/a 19288 Minimum Total Load 65759 83580 X 1. 3 $s y ST o M/ N H} • 61-V Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' FloorArea ....................... 985 sf Volume ........................... 11820 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6507 2266 Glazing Conduction ............... 13245 11851 Glazing Solar .................... n/a 6847 Infiltration ..................... 6242 4131 Internal Gain .................... n/a 2250 Ducts ............................ 2599 2734 Sensible Load .................... 28593 30079 Latent Load ...................... n/a 9024 Minimum Zone Load 28593 39103 ZONE 'LIVING2' Floor Area ....................... 323 sf Volume ........................... 3230 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Heating (Btuh) 3686 1596 n/a 1706 n/a 699 7686 Latent Load ...................... n/a Minimum Zone Load 7686 Cooling (Btuh) 1356 1428 1171 1129 225 531 5840 1752 7591 HVAC SIZING Page 3 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 ZONE 'SLEEPING' Floor Area ....................... 1510 sf Volume ........................... 16610 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 11189 Glazing Conduction ............... 6840 Glazing Solar .................... n/a Infiltration ..................... 8771 Internal Gain .................... n/a Ducts ............................ 2680 Sensible Load .................... 29480 LatentLoad ...................... n/a Minimum Zone Load 29480 4441 6120 9429 5804 0 2579 28374 8512 36887 HVAC SIZING Page 4 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range..... ..... Interior Shading Used Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2818 sf 31660 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Latent Load ...................... 90 deg (E) Heating Cooling (Btuh) (Btuh) 21382 8063 21681 19399 n/a 20697 16718 11064 n/a 2475 5978 6170 65759 n/a 67867 20360 Minimum Total Load 65759 88227 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. x� HVAC SIZING Page 5 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 985 sf Volume........................... 11820 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6507' 2266 Glazing Conduction ............... 13245 11851 Glazing Solar .................... n/a 9003 Infiltration ..................... 6242 4131 Internal Gain .................... n/a 2250 Ducts ............................ 2599 2950 Sensible Load .................... 28593 32451 Latent Load ...................... n/a 9735 Minimum Zone Load 28593 42186 ZONE 'LIVING2' Floor Area ....................... 323 sf Volume ........................... 3230 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ SensibleLoad .................... Heating Cooling (Btuh) (Btuh) 3686 1356 1596 1428 n/a 3083 1706 1129 n/a 225 699 722 7686 7942 Latent Load ...................... n/a 2383 Minimum Zone Load 7686 10325 HVAC SIZING Page 6 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 ZONE 'SLEEPING' Floor Area ....................... 1510 sf Volume ........................... 16610 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 11189 4441 Glazing Conduction ............... 6840 6120 Glazing Solar .................... n/a 8611 Infiltration ..................... 8771 5804 Internal Gain .................... n/a 0 Ducts ............................ 2680 2498 Sensible Load .................... 29480 27474 Latent Load ...................... n/a 8242 Minimum Zone Load 29480 35716 HVAC SIZING Page 7 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 2818 sf 31660 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21382 8063 Glazing Conduction ............... 21681 19399 Glazing Solar .................... n/a 16499 Infiltration ..................... 16718 11064 Internal Gain .................... n/a 2475 Ducts ............................ 5978 5750 Sensible Load .................... 65759 63250 Latent Load ...................... n/a 18975 Minimum Total Load 65759 82225 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' FloorArea ....................... 985 sf Volume ........................... 11820 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6507 2266 Glazing Conduction ............... 13245 11851 Glazing Solar .................... n/a 7247 Infiltration ..................... 6242 4131 Internal Gain .................... n/a 2250 Ducts ............................ 2599 2774 Sensible Load .................... 28593 30519 Latent Load ...................... n/a 9156 Minimum Zone Load 28593 39675 ZONE 'LIVING2' FloorArea ....................... 323 sf Volume ........................... 3230 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 3686 1356 Glazing Conduction ............... 1596 1428 Glazing Solar .................... n/a 938 Infiltration ..................... 1706 1129 Internal Gain .................... n/a 225 Ducts ............................ 699 508 Sensible Load .................... 7686 5583 Latent Load ...................... n/a 1675 Minimum Zone Load 7686 7258 HVAC SIZING Page 9 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 ZONE 'SLEEPING' Floor Area ....................... 1510 sf Volume ........................... 16610 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... LatentLoad ...................... Heating Cooling (Btuh) (Btuh) 11189 4441 6840 6120 n/a 8314 8771 5804 n/a 0 2680 2468 29480 27148 n/a 8144 Minimum Zone Load 29480 35292 HVAC SIZING Page 10 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 GENERAL INFORMATION FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location............ Latitude... ..... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange.. ..... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 2818 sf 31660 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Description (Btuh) Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration..................... InternalGain .................... Ducts............................ Sensible Load .................... LatentLoad ...................... 270 deg (W) Cooling (Btuh) 21382 8063 21681 19399 n/a 20362 16718 11064 n/a 2475 5978 6136 65759 67499 n/a 20250 Minimum Total Load 65759 87748 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 11 HVAC Project Title.......... Rielly Homes - Plan 43 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 985 sf Volume ........................... 11820 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 6507 2266 Glazing Conduction ............... 13245 11851 Glazing Solar .................... n/a 8506 Infiltration ..................... 6242 4131 Internal Gain .................... n/a 2250 Ducts ............................ 2599 2900 Sensible Load .................... 28593 31904 Latent Load ...................... n/a 9571 Minimum Zone Load 28593 41475 ZONE 'LIVING2' FloorArea ....................... 323 sf Volume ........................... 3230 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 3686 1356 Glazing Conduction ............... 1596 1428 Glazing Solar .................... n/a 3030 Infiltration ..................... 1706 1129 Internal Gain .................... n/a 225 Ducts ............................ 699 717 Sensible Load .................... 7686 7884 Latent Load ...................... n/a 2365 Minimum Zone Load 7686 10249 HVkC SIZING Page 12 HVAC Project Title.......... Rielly Homes - Plan #3 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI3TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #3 ZONE 'SLEEPING' Floor Area ....................... 1510 sf Volume ........................... 16610 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 11189 4441 Glazing Conduction ............... 6840 6120 Glazing Solar .................... n/a 8826 Infiltration ..................... 8771 5804 InternalGain .................... n/a 0 Ducts ............................ 2680 2519 Sensible Load .................... 29480 27711 Latent Load ...................... n/a 8313 Minimum Zone Load 29480 36024 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 GENERAL INFORMATION Conditioned Floor Area..... 3222 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ...... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 32.9 % of floor area Average Glazing U-value.... 0.56 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R-value R-value R-value U-value Location/Comments Wall Wood R-21 R-n/a R-21 0.059 Front Wall, Gar. Wall Left Wall, Back Wall Right Wall Roof Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door S1abEdge n/a R-0 R-n/a R-0 0.900 Exp.To Outside S1abEdge n/a R-0 R-n/a R-0 0.720 Cvd.To Outside S1abEdge n/a R-0 R-n/a R-0 0.550 Exp.To Garage S1abEdge n/a R-0 R-n/a R-0 0.500 Cvd.To Garage Wall Wood R-0 R-n/a R-0 0.293 Wall n/a R-0 R-n/a R-0 20.000 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (N) 7.5 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 16.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 16.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.550 2 CEC Std.Default None Yes Wood Window Left (E) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Door Left (E) 24.0 0.590 2 CEC Std.Default None Yes Wood Window Left (E) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Left (E) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 15.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 20.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 20.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 8.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 16.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 72.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 72.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 60.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 27.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 4.5 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 25.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 25.0 0.500 2 CEC Std.Default None Yes Vinyl THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 366 3.5 Exp.Conc.Slab (See Note) S1abOnGrade Yes 48 3.5 Exp.Conc.Slab (See Note) S1abOnGrade No 1126 3.5 Covered Concrete Slab S1abOnGrade No 310 3.5 Covered Concrete Slab S1abOnGrade No 1372 3.5 Covered Concrete Slab InteriorHorz Yes 55 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorHorz Yes 19 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 14 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 55 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 182 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh CVTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-6 LivingStat AirCond 12.00 SEER Attic R-6 LivingStat Furnace 0.800 AFUE Attic R-6 LivingStat AirCond 12.00 SEER Attic R-6 LivingStat Furnace 0.800 AFUE Attic R-6 SleepingStat AirCond 12.00 SEER Attic R-6 SleepingStat WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value Storage Gas Recirc/TimeTemp 1 .51 EF 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen/Pantry ** Nook/Bar 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Family Glass ** Rear M.Bedroom Glass Door ** Rear Living & Dining Glass * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Rielly Homes Address. 23 Corporate P1azaDr,#245 Newport Beach, CA 92660 Phone... (949) 719-4975 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24 Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 S igned .. /� Z (d to CdMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.29 2.89 0.40 Space Cooling.......... 32.31 32.27 0.04 Water Heating.......... 8.11 7.99 0.12 North Total 43.71 43.15 0.56 Space Heating.......... 3.29 3.43 -0.14 Space Cooling.......... 32.31 31.27 1.04 Water Heating.......... 8.11 7.99 0.12 East Total 43.71 42.69 1.02 Space Heating.......... 3.29 3.86 -0.57 Space Cooling.......... 32.31 30.57 1.74 Water Heating.......... 8.11 7.99 0.12 South Total 43.71 42.42 1.29 Space Heating.......... 3.29 2.84 0.45 Space Cooling.......... 32.31 31.41 0.90 Water Heating.......... 8.11 7.99 0.12 West Total 43.71 42.24 1.47 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3222 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 C6MPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY14TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 Conditioned Volume......... 39608 cf Footprint Area ............. 3222 sf Ground Floor Area.......... 3222 sf Slab -On -Grade Area......... 3222 sf Glazing Percentage......... 32.9 % of floor area Average Glazing U-value.... 0.56 Btu/hr-sf-F Average Ceiling Height..... 12.3 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) LIVINGI Living 1492 20888 0.83 Yes LivingStat 2.0 n/a LIVING2 Living 310 3100 0.17 Yes LivingStat 2.0 n/a SLEEPING Sleeping 1420 15620 0.00 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments LIVINGI 1 Wall 252 0.059 21 0 90 Yes None Front Wall 6 Wall 195 0.059 21 90 90 Yes None Left Wall 9 Wall 378 0.059 21 180 90 Yes None Back Wall 12 Wall 370 0.059 21 270 90 Yes None Right Wall 15 Roof 1492 0.025 38 n/a 0 Yes None Vented Attic LIVING2 2 Wall 83 0.059 21 0 90 Yes None Front Wall 5 Wall 120 0.059 21 0 90 No None Gar. Wall 7 Wall 144 0.059 21 90 90 Yes None Left Wall 10 Wall 180 0.059 21 180 90 Yes None Back Wall 13 Wall 110 0.059 21 270 90 Yes None Right Wall 16 Roof 310 0.025 38 n/a 0 Yes None Vented Attic SLEEPING 3 Wall 220 0.059 21 0 90 Yes None Front Wall 4 Wall 232 0.059 21 0 90 No None Gar. Wall 8 Wall 550 0.059 21 90 90 Yes None Left Wall 11 Wall 124 0.059 21 180 90 Yes None Back Wall 14 Wall 455 0.059 21 270 90 Yes None Right Wall 17 Roof 1420 0.025 38 n/a 0 Yes None Vented Attic 18 Door 21 0.330 0 0 90 No None Garage Door CdMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVINGI 19 SlabEdge 31 0.900 R-0 No Exp.To Outside 20 SlabEdge 97 0.720 R-0 No Cvd.To Outside LIVING2 21 SlabEdge 60 0.720 R-0 No Cvd.To Outside 25 SlabEdge 12 0.500 R-0 No Cvd.To Garage SLEEPING 22 SlabEdge 157 0.720 R-0 No Cvd.To Outside 23 SlabEdge 6 0.550 R-0 No Exp.To Garage 24 SlabEdge 17 0.500 R-0 No Cvd.To Garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description LIVINGI 2 Window 16.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 3 Window 48.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 4 Window 16.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 5 Window 24.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 6 Door 48.0 2 Wood Slider 0.550 0 90 0.70 0.78 CEC Std.Default 8 Door 24.0 2 Wood Slider 0.590 90 90 0.70 0.78 CEC Std.Default 9 Window 5.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 19 Window 80.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 20 Window 8.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 21 Window 16.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 22 Door 80.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 23 Window 72.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 24 Window 72.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 32 Window 36.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 33 Window 12.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 34 Window 27.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 35 Window 12.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 36 Window 4.5 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default LIVING2 1 Window 7.5 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 7 Window 6.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 28 Door 48.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default SLEEPING 10 Window 36.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 11 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 12 Window 36.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 13 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 14 Window 15.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 15 Window 6.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 16 Window 20.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 17 Window 20.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 18 Window 5.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 25 Door 60.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description 26 Window 12.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 27 Window 36.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 29 Window 36.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 30 Window 12.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 31 Window 24.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 37 Window 25.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 38 Window 6.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 39 Window 25.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght LIVINGI 2 Window 16.0 2.0 n/a 7.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 48.0 6.0 n/a 7.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 16.0 2.0 n/a 7.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 24.0 4.0 n/a 4.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 48.0 4.0 n/a 4.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 24.0 8.0 n/a 20. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 5.0 1.7 n/a 20. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 80.0 6.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 8.0 1.0 n/a 17. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 16.0 1.0 n/a 16. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 22 Door 80.0 10. n/a 17. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 23 Window 72.0 9.0 n/a 16. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 72.0 9.0 n/a 16. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 32 Window 36.0 6.0 n/a 1.0 9.0 n/a n/a n/a n/a n/a n/a n/a n/a 33 Window 12.0 2.0 n/a 1.0 7.0 n/a n/a n/a n/a n/a n/a n/a n/a 34 Window 27.0 4.5 n/a 1.0 12.5 n/a n/a n/a n/a n/a n/a n/a n/a 35 Window 12.0 2.0 n/a 1.0 17. n/a n/a n/a n/a n/a n/a n/a n/a 36 Window 4.5 1.5 n/a 1.0 10. n/a n/a n/a n/a n/a n/a n/a n/a LIVING2 1 Window 7.5 5.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 6.0 3.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 28 Door 48.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a SLEEPING 10 Window 36.0 6.0 n/a 1.0 6.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 12.0 2.0 n/a 1.0 12. n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 36.0 6.0 n/a 1.0 9.0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 12.0 2.0 n/a 1.0 15. n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 15.0 6.0 n/a 1.0 18. n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 6.0 3.0 n/a 1.0 10. n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 20.0 4.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 20.0 4.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 5.0 2.0 n/a 1.0 18. n/a n/a n/a n/a n/a n/a n/a n/a 25 Door 60.0 10. n/a 10. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 12.0 2.0 n/a 1.0 7.0 n/a n/a n/a n/a n/a n/a n/a n/a C6MPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 OVERHANGS AND SIDE FINS Window- -Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 27 Window 36.0 6.0 n/a 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 29 Window 36.0 6.0 n/a 10. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 30 Window 12.0 2.0 n/a 10. 8.0 n/a n/a n/a n/a n/a n/a n/a n/a 31 Window 24.0 8.0 n/a 20. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 37 Window 25.0 5.0 n/a 1.0 8.0 n/a n/a n/a n/a n/a n/a n/a n/a 38 Window 6.0 3.0 n/a 1.0 5.0 n/a n/a n/a n/a n/a n/a n/a n/a 39 Window 25.0 5.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a INTER -ZONE SURFACES Area Insul Form 3 Surface (sf) U-value R-val Reference Location/Comments LIVINGI/SLEEPING 1 Wall 480 0.293 R-0 NONE 2 Wall 30 20.000 R-0 NONE THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R-value Location/Comments LIVINGI 1 SlabOnGrade 366 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 3 SlabOnGrade 1126 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 6 InteriorHorz 55 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 8 InteriorVert 14 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh LIVING2 4 SlabOnGrade 310 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 9 InteriorVert 55 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh SLEEPING 2 SlabOnGrade 48 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 5 SlabOnGrade 1372 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 7 InteriorHorz 19 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 10 InteriorVert 182 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVINGI Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 LIVING2 Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 SLEEPING Furnace 0.800 AFUE Attic R-6 0.839 AirCond 12.00 SEER Attic R-6 0.827 c6APUTER METHOD SUMMARY Page 6 C-2R Project Title.......... Rielly Homes - Plan #4 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 Tank Type Heater Type WATER HEATING SYSTEMS Number in Energy Distribution Type System Factor 1 Storage Gas Recirc/TimeTemp 1 .51 Tank External Size Insulation (gal) R-value 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen/Pantry ** Nook/Bar 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Family Glass ** Rear M.Bedroom Glass Door ** Rear Living & Dining Glass * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. HVAC SIZING Page 1 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ....... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange.. ..... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3222 sf 39608 cf Front Facing 0 deg (N) LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 21304 10821 Glazing Conduction ............... 22525 20154 Glazing Solar .................... n/a 20705 Infiltration ..................... 20915 13841 Internal Gain .................... n/a 2643 Ducts ............................ 6474 6816 Sensible Load .................... 71218 74981 Latent Load ...................... n/a 22494 Minimum Total Load 71218 97475 X I 3 = 9Z,555 /"MIN, H47r.-. JS7v._ Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. H'VXC SIZING Page 2 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1492 sf Volume ........................... 20888 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7811 4275 Glazing Conduction ............... 13452 12036 Glazing Solar .................... n/a 8810 Infiltration ..................... 11030 7299 Internal Gain .................... n/a 2490 Ducts ............................ 3229 3491 Sensible Load .................... 35522 38402 Latent Load ...................... n/a 11521 Minimum Zone Load 35522 49923 ZONE 'LIVING2' Floor Area ....................... 310 sf Volume ........................... 3100 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 3592 1575 Glazing Conduction ............... 1169 1046 Glazing Solar .................... n/a 1099 Infiltration ..................... 1637 1083 Internal Gain .................... n/a 153 Ducts ............................ 640 496 Sensible Load .................... 7037 5452 Latent Load ...................... n/a 1635 Minimum Zone Load 7037 7087 HIAC SIZING Page 3 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 ZONE 'SLEEPING' Floor Area ....................... 1420 sf Volume ........................... 15620 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9901 4971 Glazing Conduction ............... 7904 7072 Glazing Solar .................... n/a 10796 Infiltration ..................... 8248 5458 Internal Gain .................... n/a 0 Ducts ............................ 2605 2830 Sensible Load .................... 28658 31127 Latent Load ...................... n/a 9338 Minimum Zone Load 28658 40465 HVAC SIZING Page 4 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 GENERAL INFORMATION FloorArea ................. Volume....... ............ Front Orientation.......... Sizing Location............ Latitude... .... ....... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange.. ... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3222 sf 39608 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Description (Btuh) Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... 90 deg (E) Cooling (Btuh) 21304 10821 22525 20154 n/a 18324 20915 13841 n/a 2643 6474 6578 71218 72362 Latent Load ...................... n/a 21709 Minimum Total Load 71218 94070 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. ti t HVAC SIZING Page 5 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1492 sf Volume ........................... 20888 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7811 4275 Glazing Conduction ............... 13452 12036 Glazing Solar .................... n/a 9053 Infiltration ..................... 11030 7299 Internal Gain .................... n/a 2490 Ducts ............................ 3229 3515 Sensible Load .................... 35522 38670 Latent Load ...................... n/a 11601 Minimum Zone Load 35522 50271 ZONE 'LIVING2' Floor Area ....................... 310 sf Volume ........................... 3100 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 3592 1575 Glazing Conduction ............... 1169 1046 Glazing Solar .................... n/a 2271 Infiltration ..................... 1637 1083 Internal Gain .................... n/a 153 Ducts ............................ 640 613 Sensible Load .................... 7037 6741 Latent Load ...................... n/a 2022 Minimum Zone Load 7037 8763 Y 1 i OAC SIZING Page 6 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 ZONE 'SLEEPING' Floor Area ....................... 1420 sf Volume ........................... 15620 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Heating Cooling (Btuh) (Btuh) 9901 4971 7904 7072 n/a 7000 8248 5458 n/a 0 2605 2450 28658 n/a Minimum Zone Load 28658 26952 8085 35037 ,s HVAC SIZING Page 7 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 .�yi��yi�i:�i■I��i4C�� �vili����J Floor Area ................. 3222 sf Volume.. ............ 39608 cf Front Orientation.......... Front Facing Sizing Location............ LA QUINTA Latitude... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. .... ..... 34 F Interior Shading Used ...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 Description HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21304 10821 Glazing Conduction ............... 22525 20154 Glazing Solar .................... n/a 19291 Infiltration ..................... 20915 13841 Internal Gain .................... n/a 2643 Ducts ............................ 6474 6675 Sensible Load .................... 71218 73425 Latent Load ...................... n/a 22028 Minimum Total Load 71218 95453 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1492 sf Volume ........................... 20888 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... ZONE 'LIVING2' Heating (Btuh) 7811 13452 n/a 11030 n/a 3229 35522 n/a Minimum Zone Load 35522 FloorArea ....................... 310 sf Volume ........................... 3100 cf Description Cooling (Btuh) 4275 12036 8060 7299 2490 3416 37577 MOVx*3 48850 Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 3592 1575 Glazing Conduction ............... 1169 1046 Glazing Solar .................... n/a 708 Infiltration ..................... 1637 1083 Internal Gain .................... n/a 153 Ducts............................ 640 457 Sensible Load .................... 7037 5022 LatentLoad ...................... n/a Minimum Zone Load 7037 1506 6528 v, KC SIZING Page 9 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 ZONE 'SLEEPING' Floor Area ....................... 1420 sf Volume ........................... 15620 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ SensibleLoad .................... Latent Load ...................... Minimum Zone Load Heating Cooling (Btuh) (Btuh) 9901 4971 7904 7072 n/a 10523 8248 5458 n/ a 0 2605 2802 28658 30827 n/a 9248 28658 40075 HVAC SIZING Page 10 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 GENERAL INFORMATION FloorArea ................. Volume.. . ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange .. ..... ...... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3222 sf 39608 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21304 10821 Glazing Conduction ............... 22525 20154 Glazing Solar .................... n/a 18172 Infiltration ..................... 20915 13841 Internal Gain .................... n/a 2643 Ducts ............................ 6474 6563 Sensible Load .................... 71218 72194 Latent Load ...................... n/a 21658 Minimum Total Load 71218 93853 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. ♦ . HVAC SIZING Page 11 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1492 sf Volume ........................... 20888 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7811 4275 Glazing Conduction ............... 13452 12036 Glazing Solar .................... n/a 9896 Infiltration ..................... 11030 7299 Internal Gain .................... n/a 2490 Ducts ............................ 3229 3600 Sensible Load .................... 35522 Latent Load ...................... n/a Minimum Zone Load 35522 ZONE 'LIVING2' Floor Area ....................... 310 sf Volume ........................... 3100 cf Description 39597 11879 51476 Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 3592 1575 Glazing Conduction ............... 1169 1046 Glazing Solar .................... n/a 2226 Infiltration ..................... 1637 1083 Internal Gain .................... n/a 153 Ducts ............................ 640 608 Sensible Load .................... 7037 6691 Latent Load ...................... n/a Minimum Zone Load 7037 2007 8699 �t HVAC SIZING Page 12 HVAC Project Title.......... Rielly Homes - Plan #4 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI4TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #4 ZONE 'SLEEPING' Floor Area ....................... 1420 sf Volume ........................... 15620 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9901 4971 Glazing Conduction ............... 7904 7072 Glazing Solar .................... n/a 6050 Infiltration ..................... 8248 5458 Internal Gain .................... n/a 0 Ducts ............................ 2605 2355 Sensible Load .................... 28658 25906 Latent Load ...................... n/a 7772 Minimum Zone Load 28658 33678 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Project Address........ Documentation Author... Climate Zone. ..... Compliance Method...... Rielly Homes - Plan #5 PGA West (Job #097-98085)******* La Quinta, California *v4.51* Rick Maurer ******* Rick Maurer Title 24 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 15 Page 1 CF-1R Date........ 11/24/98 Building Permit Plan Check / Date Field Check Date MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 GENERAL INFORMATION Conditioned Floor Area..... 3409 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ...... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 36.8 % of floor area Average Glazing U-value.... 0.57 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R-value R-value R-value U-value Location/Comments Wall Wood R-21 R-n/a R-21 0.059 Front Wall, Gar. Wall Left Wall, Back Wall Right Wall RoofRadiant Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door S1abEdge n/a R-0 R-n/a R-0 0.900 Exp.To Outside S1abEdge n/a R-0 R-n/a R-0 0.720 Cvd.To Outside S1abEdge n/a R-0 R-n/a R-0 0.550 Exp.To Garage S1abEdge n/a R-0 R-n/a R-0 0.500 Cvd.To Garage Wall Wood R-0 R-n/a R-0 0.293 Wall n/a R-0 R-n/a R-0 20.000 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (N) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 30.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 10.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.550 2 CEC Std.Default None Yes Wood CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM CF-lR User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Left (E) 72.0 0.650 2 CEC Std.Default None Yes Metal Window Left (E) 8.0 0.650 2 CEC Std.Default None Yes Metal Door Left (E) 24.0 0.590 2 CEC Std.Default None Yes Wood Window Left (E) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 3.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 16.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 72.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 6.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 60.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 100.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 20.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 90.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 12.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 36.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 64.0 0.500 2 CEC Std.Default None Yes Vinyl Door Right (W) 60.0 0.650 2 CEC Std.Default None Yes Metal Window Right (W) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 30.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 30.0 0.500 2 CEC Std.Default None Yes Vinyl THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments SlabOnGrade Yes 534 3.5 Exp.Conc.Slab (See Note) SlabOnGrade Yes 51 3.5 Exp.Conc.Slab (See Note) SlabOnGrade No 1037 3.5 Covered Concrete Slab SlabOnGrade No 373 3.5 Covered Concrete Slab SlabOnGrade No 1414 3.5 Covered Concrete Slab InteriorHorz Yes 87 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorHorz Yes 22 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 21 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 55 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 192 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM CF-1R User4-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-8 LivingStat AirCond 12.00 SEER Attic R-8 LivingStat Furnace 0.800 AFUE Attic R-8 LivingStat AirCond 12.00 SEER Attic R-8 LivingStat Furnace 0.800 AFUE Attic R-8 SleepingStat AirCond 12.00 SEER Attic R-8 SleepingStat WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value Storage Gas Recirc/TimeTemp 1 .51 EF 75 R-12 SPECIAL FEATURES/REMARKS Phis building incorporates a Zonally Controlled HVAC System. this is a multiple orientation building with no orientation restrictions. this printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry/Bar ** Laundry ** Hearth ** Kitchen ** Nook/ Pantries 5) All glass will be dual pane with a shade coefficient of .70 or less with the exception of all the metal frame fenistration which will have LOW-E2 or equal and a shade coefficient of .50 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Family Glass ** 8x9 & 8x1 Family Glass ** Rear Living Glass ** Side Retreat Glass Door ** Nook Glass Door & 6X1 Transom Only When door Is Used * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. CEkTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 SPECIAL FEATURES/REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Rielly Homes Address. 23 Corporate P1azaDr,#245 Newport Beach, CA 92660 Phone... (949) 719-4975 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24 Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 Signed.�- ( te) COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Chec / Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 3.18 3.05 0.13 Space Cooling.......... 31.68 30.29 1.39 Water Heating.......... 7.66 7.55 0.11 North Total 42.52 40.89 1.63 Space Heating.......... 3.18 3.24 -0.06 Space Cooling.......... 31.68 31.49 0.19 Water Heating.......... 7.66 7.55 0.11 East Total 42.52 42.28 0.24 Space Heating.......... 3.18 3.56 -0.38 Space Cooling.......... 31.68 29.73 1.95 Water Heating.......... 7.66 7.55 0.11 South Total 42.52 40.84 1.68 Space Heating.......... 3.18 3.34 -0.16 Space Cooling.......... 31.68 31.02 0.66 Water Heating.......... 7.66 7.55 0.11 West Total 42.52 41.91 0.61 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 3409 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 3 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 Conditioned Volume......... 41839 cf Footprint Area ............. 3409 sf Ground Floor Area.......... 3409 sf Slab -On -Grade Area......... 3409 sf Glazing Percentage......... 36.8 % of floor area Average Glazing U-value.... 0.57 Btu/hr-sf-F Average Ceiling Height..... 12.3 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) LIVINGI Living 1571 21994 0.81 Yes LivingStat 2.0 n/a LIVING2 Living 373 3730 0.19 Yes LivingStat 2.0 n/a SLEEPING Sleeping 1465 16115 0.00 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments LIVINGI 1 Wall 265 0.059 21 0 90 Yes None Front Wall 5 Wall 256 0.059 21 90 90 Yes None Left Wall 8 Wall 296 0.059 21 180 90 Yes None Back Wall 11 Wall 396 0.059 21 270 90 Yes None Right Wall 14 RoofRadiant 1571 0.025 38 n/a 0 Yes None Vented Attic LIVING2 2 Wall 172 0.059 21 0 90 Yes None Front Wall 6 Wall 188 0.059 21 90 90 Yes None Left Wall 9 Wall 126 0.059 21 180 90 Yes None Back Wall 12 Wall 176 0.059 21 270 90 Yes None Right Wall 15 RoofRadiant 373 0.025 38 n/a 0 Yes None Vented Attic SLEEPING 3 Wall 174 0.059 21 0 90 Yes None Front Wall 4 Wall 199 0.059 21 0 90 No None Gar. Wall 7 Wall 527 0.059 21 90 90 Yes None Left Wall 10 Wall 123 0.059 21 180 90 Yes None Back Wall 13 Wall 384 0.059 21 270 90 Yes None Right Wall 16 RoofRadiant 1465 0.025 38 n/a 0 Yes None Vented Attic 17 Door 21 0.330 0 0 90 No None Garage Door COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVINGI 18 SlabEdge 30 0.900 R-0 No Exp.To Outside 19 SlabEdge 114 0.720 R-0 No Cvd.To Outside LIVING2 20 SlabEdge 78 0.720 R-0 No Cvd.To Outside SLEEPING 21 SlabEdge 145 0.720 R-0 No Cvd.To Outside 22 SlabEdge 7 0.550 R-0 No Exp.To Garage 23 SlabEdge 13 0.500 R-0 No Cvd.To Garage FENESTRATION SURFACES # of Vent SC Sc Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description LIVINGI 4 Window 36.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 5 Window 24.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 6 Window 24.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 7 Window 18.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 8 Window 6.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 9 Window 36.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 10 Window 12.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 11 Door 48.0 2 Wood Slider 0.550 0 90 0.70 0.78 CEC Std.Default 12 Window 72.0 2 Metal Slider 0.650 90 90 0.50 0.78 CEC Std.Default 13 Window 8.0 2 Metal Slider 0.650 90 90 0.50 0.78 CEC Std.Default 14 Door 24.0 2 Wood Slider 0.590 90 90 0.70 0.78 CEC Std.Default 15 Window 5.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 16 Window 3.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 22 Window 18.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 23 Window 6.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 26 Door 80.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 27 Window 16.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 28 Window 72.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 29 Window 6.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 30 Door 60.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 31 Door 100.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 32 Window 20.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 33 Window 90.0 2 Metal Slider 0.650 180 90 0.50 0.78 CEC Std.Default 38 Window 24.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default LIVING2 1 Window 18.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 36 Door 64.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default SLEEPING 2 Window 30.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 3 Window 10.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 17 Window 36.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 18 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 19 Window 48.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 20 Window 18.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 FENESTRATION SURFACES # of Vent Sc Sc Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description 21 Window 6.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 24 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 25 Window 12.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 34 Window 12.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 35 Window 36.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 37 Door 60.0 2 Metal Slider 0.650 270 90 0.50 0.78 CEC Std.Default 39 Window 30.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 40 Window 6.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 41 Window 6.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 42 Window 30.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght LIVINGI 4 Window 36.0 6.0 n/a 6.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 24.0 4.0 n/a 6.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 24.0 4.0 n/a 6.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 18.0 6.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 6.0 2.0 n/a 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 36.0 6.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 12.0 2.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 11 Door 48.0 8.0 n/a 6.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 72.0 9.0 n/a 11. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 8.0 1.0 n/a 11. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Door 24.0 8.0 n/a 11. 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 5.0 1.7 n/a 11. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 3.0 1.0 n/a 11. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 18.0 3.0 n/a 1.0 4.5 n/a n/a n/a n/a n/a n/a n/a n/a 23 Window 6.0 2.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 26 Door 80.0 10. n/a 8.0 8.0 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 16.0 1.0 n/a 8.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 72.0 9.0 n/a 8.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 29 Window 6.0 1.0 n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 30 Door 60.0 10. n/a 15. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 31 Door 100.0 10. n/a 11. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 32 Window 20.0 1.0 n/a 11. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 33 Window 90.0 9.0 n/a 11. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 38 Window 24.0 3.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a LIVING2 1 Window 18.0 4.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 36 Door 64.0 8.0 n/a 1.0 4.5 n/a n/a n/a n/a n/a n/a n/a n/a SLEEPING 2 Window 30.0 6.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 10.0 2.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 36.0 6.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 12.0 2.0 n/a 1.0 9.5 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 19 Window 48.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 18.0 3.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 6.0 3.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 24 Window 12.0 4.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 25 Window 12.0 4.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 34 Window 12.0 2.0 n/a 1.0 7.0 n/a n/a n/a n/a n/a n/a n/a n/a 35 Window 36.0 6.0 n/a 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 37 Door 60.0 10. n/a 10. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 39 Window 30.0 5.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a 40 Window 6.0 3.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a 41 Window 6.0 3.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a 42 Window 30.0 5.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a INTER -ZONE SURFACES Area Insul Form 3 Surface (sf) U-value R-val Reference Location/Comments LIVINGI/SLEEPING 1 Wall 310 0.293 R-0 NONE 2 Wall 30 20.000 R-0 NONE THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R-value Location/Comments LIVINGI 1 SlabOnGrade 534 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 3 S1abOnGrade 1037 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 6 InteriorHorz 87 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 8 InteriorVert 21 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh LIVING2 4 S1abOnGrade 373 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 9 InteriorVert 55 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh SLEEPING 2 S1abOnGrade 51 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 5 S1abOnGrade 1414 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 7 InteriorHorz 22 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 10 InteriorVert 192 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh COMPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICR0PAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 HVAC SYSTEMS Minimum Duct System Type Efficiency Location LIVINGI Furnace 0.800 AFUE Attic AirCond 12.00 SEER Attic LIVING2 Furnace 0.800 AFUE Attic AirCond 12.00 SEER Attic SLEEPING Furnace 0.800 AFUE Attic AirCond 12.00 SEER Attic WATER HEATING SYSTEMS Tank Type Heater Type Distribution Type 1 Storage Gas Recirc/TimeTemp Duct Duct R-value Efficiency R-8 0.850 R-8 0.840 R-8 0.850 R-8 0.840 R-8 0.850 R-8 0.840 Number Tank External in Energy Size Insulation System Factor (gal) R-value 1 .51 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry/Bar ** Laundry ** Hearth ** Kitchen ** Nook/Pantries 5) All glass will be dual pane with a shade coefficient of .70 or less with the exception of all the metal frame fenistration which will have LOW-E2 or equal and a shade coefficient of .50 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear Family Glass ** 8x9 & 8x1 Family Glass ** Rear Living Glass ** Side Retreat Glass Door ** Nook Glass Door & 6X1 Transom Only When door Is Used * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. COMPUTER METHOD SUMMARY Page 7 C-2R Project Title.......... Rielly Homes - Plan #5 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 SPECIAL FEATURES/REMARKS HVJXC SIZING Project Title.......... Project Address........ Documentation Author... Climate Zone.. ..... Compliance Method...... Rielly Homes - Plan #5 PGA West (Job #097-98085)******* La Quinta, California *v4.51* Rick Maurer ******* Rick Maurer Title 24 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 15 Page 1 HVAC Date........ 11/23/98 Building Permit Plan Check / Date Field Check/ Date MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 GENERAL INFORMATION FloorArea ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... .... ....... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3409 sf 41839 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 0 deg (N) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21500 8423 Glazing Conduction ............... 27328 24451 Glazing Solar .................... n/a 19725 Infiltration ..................... 22093 14621 Internal Gain .................... n/a 2601 Ducts ............................ 7092 6982 Sensible Load .................... 78013 76804 Latent Load ...................... n/a 23041 Minimum Total Load 78013 99845 , x 1,3 = lol,4)(o re) iN• 1-4�•i3rv-_ Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. iftC SIZING Page 2 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 1571 sf Volume ........................... 21994 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 8357 3276 Glazing Conduction ............... 18512 16563 Glazing Solar .................... n/a 7940 Infiltration ..................... 11614 7686 Internal Gain .................... n/a 2430 Ducts............................ 3848 3790 Sensible Load .................... 42331 41685 Latent Load ...................... n/a 12505 Minimum Zone Load 42331 54190 ZONE 'LIVING2' Floor Area ....................... 373 sf Volume ........................... 3730 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 3973 1497 Glazing Conduction ............... 1558 1394 Glazing Solar .................... n/a 1256 Infiltration ..................... 1970 1303 Internal Gain .................... n/a 171 Ducts ............................ 750 562 Sensible Load .................... 8250 6184 Latent Load ...................... n/a 1855 Minimum Zone Load 8250 8039 ♦ It HVXC SIZING Page 3 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 ZONE 'SLEEPING' Floor Area ....................... 1465 sf Volume ........................... 16115 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9170 3651 Glazing Conduction ............... 7258 6494 Glazing Solar .................... n/a 10529 Infiltration ..................... 8509 5631 Internal Gain .................... n/a 0 Ducts ............................ 2494 2630 Sensible Load .................... 27431 28935 Latent Load ...................... n/a 8681 Minimum Zone Load 27431 37616 �e WhC SIZING Page 4 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User4-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 GENERAL INFORMATION FloorArea ................. Volume.. ........... Front Orientation.......... Sizing Location............ Latitude... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3409 sf 41839 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Description (Btuh) 90 deg (E) Cooling (Btuh) Opaque Conduction and Solar...... 21500 8423 Glazing Conduction ............... 27328 24451 Glazing Solar .................... n/a 23802 Infiltration ..................... 22093 14621 Internal Gain .................... n/a 2601 Ducts ............................ 7092 7390 Sensible Load .................... 78013 81289 Latent Load ...................... n/a 24387 Minimum Total Load 78013 105675 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 5 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1571 sf Volume ........................... 21994 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 8357 3276 Glazing Conduction ............... 18512 16563 Glazing Solar .................... n/a 14015 Infiltration ..................... 11614 7686 Internal Gain .................... n/a 2430 Ducts ............................ 3848 4397 Sensible Load .................... 42331 48367 Latent Load ...................... n/a 14510 Minimum Zone Load 42331 62877 ZONE 'LIVING2' Floor Area ....................... 373 sf Volume ........................... 3730 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 3973 1497 Glazing Conduction ............... 1558 1394 Glazing Solar .................... n/a 3201 Infiltration ..................... 1970 1303 Internal Gain .................... n/a 171 Ducts ............................ 750 757 Sensible Load .................... 8250 8323 Latent Load ...................... n/a 2497 Minimum Zone Load 8250 10820 HVXC SIZING Page 6 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 ZONE 'SLEEPING' Floor Area ....................... 1465 sf Volume ........................... 16115 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9170 3651 Glazing Conduction ............... 7258 6494 Glazing Solar .................... n/a 6587 Infiltration ..................... 8509 5631 Internal Gain .................... n/a 0 Ducts ............................ 2494 2236 Sensible Load .................... 27431 24599 Latent Load ...................... n/a Minimum Zone Load 27431 7380 31979 HVAC SIZING Page 7 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 GENERAL INFORMATION Floor Area ................. 3409 sf Volume.. .. ............ 41839 cf Front Orientation.......... Front Facing Sizing Location............ LA QUINTA Latitude... .... ....... 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range........ ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 Description HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21500 8423 Glazing Conduction ............... 27328 24451 Glazing Solar .................... n/a 19452 Infiltration ..................... 22093 14621 Internal Gain .................... n/a 2601 Ducts ............................ 7092 6955 Sensible Load .................... 78013 76504 Latent Load ...................... n/a 22951 Minimum Total Load 78013 99455 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1571 sf Volume ........................... 21994 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 8357 3276 Glazing Conduction ............... 18512 16563 Glazing Solar .................... n/a 8308 Infiltration ..................... 11614 7686 Internal Gain .................... n/a 2430 Ducts ............................ 3848 3826 Sensible Load .................... 42331 42089 Latent Load ...................... n/a 12627 Minimum Zone Load 42331 54716 ZONE 'LIVING2' Floor Area ....................... 373 sf Volume ........................... 3730 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 3973 1497 Glazing Conduction ............... 1558 1394 Glazing Solar .................... n/a 684 Infiltration ..................... 1970 1303 Internal Gain .................... n/a 171 Ducts ............................ 750 505 Sensible Load .................... 8250 5555 Latent Load ...................... n/a 1666 Minimum Zone Load 8250 7221 1 HVAC SIZING Page 9 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 ZONE 'SLEEPING' Floor Area ....................... 1465 sf Volume ........................... 16115 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9170 3651 Glazing Conduction ............... 7258 6494 Glazing Solar .................... n/a 10460 Infiltration ..................... 8509 5631 Internal Gain .................... n/a 0 Ducts ............................ 2494 2624 Sensible Load .................... 27431 28860 Latent Load ...................... n/a 8658 Minimum Zone Load 27431 37518 HVXC SIZING Page 10 HVAC Project Title.......... Rielly Hammes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 GENERAL INFORMATION FloorArea ................. Volume.. .. ............ Front Orientation.......... Sizing Location............ Latitude... ..... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range.. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3409 sf 41839 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 21500 8423 Glazing Conduction ............... 27328 24451 Glazing Solar .................... n/a 23183 Infiltration ..................... 22093 14621 Internal Gain .................... n/a 2601 Ducts ............................ 7092 7328 Sensible Load .................... 78013 80608 Latent Load ...................... n/a 24182 Minimum Total Load 78013 104790 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. 4 HVAC SIZING Page 11 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 1571 sf Volume ........................... 21994 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... GlazingSolar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Heating (Btuh) 8357 18512 n/a 11614 n/a 3848 42331 LatentLoad ...................... n/a Minimum Zone Load 42331 ZONE 'LIVING2' Floor Area ....................... 373 sf Volume ........................... 3730 cf Cooling (Btuh) 3276 16563 13881 7686 2430 4384 48219 14466 Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 3973 1497 Glazing Conduction ............... 1558 1394 Glazing Solar .................... n/a 3201 Infiltration ..................... 1970 1303 Internal Gain .................... n/a 171 Ducts ............................ 750 757 Sensible Load .................... 8250 8323 Latent Load ...................... n/a 2497 Minimum Zone Load 8250 10820 HVAC SIZING Page 12 HVAC Project Title.......... Rielly Homes - Plan #5 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY25TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #5 ZONE 'SLEEPING' Floor Area ....................... 1465 sf Volume ........................... 16115 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 9170 3651 Glazing Conduction ............... 7258 6494 Glazing Solar .................... n/a 6102 Infiltration ..................... 8509 5631 Internal Gain .................... n/a 0 Ducts ............................ 2494 2188 Sensible Load .................... 27431 24066 Latent Load ...................... n/a 7220 Minimum Zone Load 27431 31285 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Project Address........ Documentation Author... Climate Zone.. ..... Compliance Method...... Rielly Homes - Plan #6 PGA West (Job #097-98085)******* La Quinta, California *v4.51* Rick Maurer ******* Rick Maurer Title 24 7544 E Saddlehill Trail Orange, CA 92869 714-771-1507 15 Page 1 CF-1R Date........ 11/24/98 Building Permit Plan Check / Date Field Check/ Date MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 GENERAL INFORMATION Conditioned Floor Area..... 3698 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.. ...... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 30.4 % of floor area Average Glazing U-value.... 0.59 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R-value R-value R-value U-value Location/Comments Wall Wood R-21 R-n/a R-21 0.059 Front Wall, Gar. Wall Left Wall, Back Wall Right Wall Roof Wood R-38 R-n/a R-38 0.025 Vented Attic Door Wood R-0 R-n/a R-0 0.330 Garage Door S1abEdge n/a R-0 R-n/a R-0 0.900 Exp.To Outside S1abEdge n/a R-0 R-n/a R-0 0.720 Cvd.To Outside S1abEdge n/a R-0 R-n/a R-0 0.550 Exp.To Garage S1abEdge n/a R-0 R-n/a R-0 0.500 Cvd.To Garage Wall Wood R-0 R-n/a R-0 0.293 Wall n/a R-0 R-n/a R-0 20.000 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (N) 20.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 4.5 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Door Front (N) 48.0 0.550 2 CEC Std.Default None Yes Wood Window Front (N) 24.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 25.0 0.500 2 CEC Std.Default None Yes Vinyl Window Front (N) 10.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 64.0 0.650 2 CEC Std.Default None Yes Metal Window Left (E) 8.0 0.650 2 CEC Std.Default None Yes Metal Window Left (E) 16.0 0.500 2 CEC Std.Default None Yes Vinyl CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Left (E) 12.5 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 40.0 0.500 2 CEC Std.Default None Yes Vinyl Window Left (E) 25.0 0.500 2 CEC Std.Default None Yes Vinyl Door Left (E) 24.0 0.590 2 CEC Std.Default None Yes Wood Window Left (E) 5.0 0.500 2 CEC Std.Default None Yes Vinyl Window Back (S) 64.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 24.0 0.650 2 CEC Std.Default None Yes Metal Door Back (S) 240.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 10.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Window Back (S) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Door Back (S) 80.0 0.650 2 CEC Std.Default None Yes Metal Door Right (W) 80.0 0.650 2 CEC Std.Default None Yes Metal Window Right (W) 8.0 0.650 2 CEC Std.Default None Yes Metal Window Right (W) 48.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 6.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 18.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 4.0 0.500 2 CEC Std.Default None Yes Vinyl Window Right (W) 30.0 0.500 2 CEC Std.Default None Yes Vinyl THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 426 3.5 Exp.Conc.Slab (See Note) S1abOnGrade Yes 46 3.5 Exp.Conc.Slab (See Note) S1abOnGrade No 1078 3.5 Covered Concrete Slab S1abOnGrade No 331 3.5 Covered Concrete Slab SlabOnGrade No 1817 3.5 Covered Concrete Slab InteriorHorz Yes 73 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorHorz Yes 34 1.0 H.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 15 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 55 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh InteriorVert Yes 246 1.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-8 LivingStat AirCond 12.00 SEER Attic R-8 LivingStat Furnace 0.800 AFUE Attic R-8 LivingStat AirCond 12.00 SEER Attic R-8 LivingStat Furnace 0.800 AFUE Attic R-8 SleepingStat AirCond 12.00 SEER Attic R-8 SleepingStat CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) Storage Gas Recirc/TimeTemp External Insulation R-value 1 .51 EF 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen/Pantry ** Nook 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear M.Bedroom Glass ** Rear Great Room Glass ** All Nook Glass * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R ?roject Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM CF-1R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Rielly Homes Address. 23 Corporate P1azaDr,#245 Newport Beach, CA 92660 Phone... (949) 719-4975 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Rick Maurer Company. Rick Maurer Title 24 Address. 7544 E Saddlehill Trail Orange, CA 92869 Phone... 714-771-1507 Signed.. // 4 9 (da e) COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 4.05 3.38 0.67 Space Cooling.......... 32.21 31.42 0.79 Water Heating.......... 7.06 6.96 0.10 North Total 43.32 41.76 1.56 Space Heating.......... 4.05 3.99 0.06 Space Cooling.......... 32.21 32.15 0.06 Water Heating.......... 7.06 6.96 0.10 East Total 43.32 43.10 0.22 Space Heating.......... 4.05 4.46 -0.41 Space Cooling.......... 32.21 29.42 2.79 Water Heating.......... 7.06 6.96 0.10 South Total 43.32 40.84 2.48 Space Heating.......... 4.05 3.47 0.58 Space Cooling.......... 32.21 31.33 0.88 Water Heating.......... 7.06 6.96 0.10 West Total 43.32 41.76 1.56 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3698 sf Single Family Detached New Cardinal - N,E,S,W 1 1 FullYear Slab On Grade 3 COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY16TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 Conditioned Volume......... 44859 cf Footprint Area ............. 3698 sf Ground Floor Area.......... 3698 sf Slab -On -Grade Area......... 3698 sf Glazing Percentage......... 30.4 % of floor area Average Glazing U-value.... 0.59 Btu/hr-sf-F Average Ceiling Height..... 12.1 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) LIVINGI Living 1504 21056 0.82 Yes LivingStat 2.0 n/a LIVING2 Living 331 3310 0.18 Yes LivingStat 2.0 n/a SLEEPING Sleeping 1863 20493 0.00 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments LIVINGI 1 Wall 366 0.059 21 0 90 Yes None Front Wall 5 Wall 529 0.059 21 90 90 Yes None Left Wall 8 Wall 256 0.059 21 180 90 Yes None Back Wall 11 Wall 170 0.059 21 270 90 Yes None Right Wall 15 Roof 1504 0.025 38 n/a 0 Yes None Vented Attic LIVING2 2 Wall 166 0.059 21 0 90 Yes None Front Wall 6 Wall 178 0.059 21 90 90 Yes None Left Wall 9 Wall 160 0.059 21 180 90 Yes None Back Wall 12 Wall 166 0.059 21 270 90 Yes None Right Wall 16 Roof 331 0.025 38 n/a 0 Yes None Vented Attic SLEEPING 3 Wall 85 0.059 21 0 90 Yes None Front Wall 4 Wall 309 0.059 21 0 90 No None Gar. Wall 7 Wall 350 0.059 21 90 90 Yes None Left Wall 10 Wall 218 0.059 21 180 90 Yes None Back Wall 13 Wall 565 0.059 21 270 90 Yes None Right Wall 14 Wall 264 0.059 21 270 90 No None Gar. Wall 17 Roof 1863 0.025 38 n/a 0 Yes None Vented Attic 18 Door 21 0.330 0 0 90 No None Garage Door COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVINGI 19 S1abEdge 47 0.900 R-0 No Exp.To Outside 20 S1abEdge 100 0.720 R-0 No Cvd.To Outside LIVING2 21 S1abEdge 76 0.720 R-0 No Cvd.To Outside SLEEPING 22 S1abEdge 147 0.720 R-0 No Cvd.To Outside 23 S1abEdge 4 0.550 R-0 No Exp.To Garage 24 SlabEdge 50 0.500 R-0 No Cvd.To Garage FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description LIVINGI 3 Door 48.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 4 Window 6.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 5 Door 48.0 2 Wood Slider 0.550 0 90 0.70 0.78 CEC Std.Default 6 Window 24.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 9 Window 64.0 2 Metal Slider 0.650 90 90 0.70 0.78 CEC Std.Default 10 Window 8.0 2 Metal Slider 0.650 90 90 0.70 0.78 CEC Std.Default 11 Window 16.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 12 Window 12.5 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 18 Window 24.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 19 Door 240.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 20 Window 10.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 21 Window 80.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 25 Door 80.0 2 Metal Slider 0.650 270 90 0.70 0.78 CEC Std.Default 26 Window 8.0 2 Metal Slider 0.650 270 90 0.70 0.78 CEC Std.Default LIVING2 1 Window 20.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 2 Window 4.5 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 23 Door 48.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default SLEEPING 7 Window 25.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 8 Window 10.0 2 Vinyl Slider 0.500 0 90 0.70 0.78 CEC Std.Default 13 Window 40.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 14 Window 25.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 15 Door 24.0 2 Wood Slider 0.590 90 90 0.70 0.78 CEC Std.Default 16 Window 5.0 2 Vinyl Slider 0.500 90 90 0.70 0.78 CEC Std.Default 17 Window 64.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 22 Window 6.0 2 Vinyl Slider 0.500 180 90 0.70 0.78 CEC Std.Default 24 Door 80.0 2 Metal Slider 0.650 180 90 0.70 0.78 CEC Std.Default 27 Window 48.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 28 Window 6.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 29 Window 18.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 30 Window 4.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default 31 Window 30.0 2 Vinyl Slider 0.500 270 90 0.70 0.78 CEC Std.Default R . COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 OVERHANGS AND SIDE FINS ---Window- -Overhang Left Fin Right Ann— Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght LIVINGI 3 Door 48.0 8.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 6.0 4.0 n/a 1.0 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 8.0 n/a 9.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 24.0 4.0 n/a 9.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 64.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 8.0 1.0 n/a 1.0 1.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 16.0 2.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 12.5 5.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 24.0 1.0 n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 19 Door 240.0 10. n/a 15. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 20 Window 10.0 1.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 21 Window 80.0 8.0 n/a 1.0 9.5 n/a n/a n/a n/a n/a n/a n/a n/a 25 Door 80.0 10. n/a 10. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 26 Window 8.0 1.0 n/a 10. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a LIVING2 1 Window 20.0 5.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 4.5 3.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 23 Door 48.0 8.0 n/a 1.0 4.5 n/a n/a n/a n/a n/a n/a n/a n/a SLEEPING 7 Window 25.0 5.0 n/a 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 10.0 2.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 40.0 5.0 n/a 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 25.0 5.0 n/a 1.0 4.0 n/a n/a n/a n/a n/a n/a n/a n/a 15 Door 24.0 8.0 n/a 15. 2.0 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 5.0 1.7 n/a 15. 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 64.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 22 Window 6.0 3.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 24 Door 80.0 10.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 27 Window 48.0 8.0 n/a 1.0 3.5 n/a n/a n/a n/a n/a n/a n/a n/a 28 Window 6.0 3.0 n/a 1.0 5.5 n/a n/a n/a n/a n/a n/a n/a n/a 29 Window 18.0 3.0 n/a 1.0 2.5 n/a n/a n/a n/a n/a n/a n/a n/a 30 Window 4.0 2.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 31 Window 30.0 8.0 n/a 1.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a INTER -ZONE SURFACES Area Insul Form 3 Surface (sf) U-value R-val Reference Location/Comments LIVINGI/SLEEPING 1 Wall 310 0.293 R-0 NONE 2 Wall 30 20.000 R-0 NONE COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 Mass Type LIVINGI THERMAL MASS Area Thick Heat Conduct- Surface (sf) (in) Cap ivity R-value Location/Comments 1 S1abOnGrade 426 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 3 S1abOnGrade 1078 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 6 InteriorHorz 73 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 8 InteriorVert 15 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh LIVING2 4 S1abOnGrade 331 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 9 InteriorVert 55 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh SLEEPING 2 S1abOnGrade 46 3.5 28.0 0.98 R-0.0 Exp.Conc.Slab (See Note) 5 S1abOnGrade 1817 3.5 28.0 0.98 R-2.0 Covered Concrete Slab 7 InteriorHorz 34 1.0 24.0 0.67 R-0.0 H.Tile-Kit.Ctr,Fp,Tub/Sh 10 InteriorVert 246 1.0 24.0 0.67 R-0.0 V.Tile-Kit.Ctr,Fp,Tub/Sh HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVINGI Furnace 0.800 AFUE Attic R-8 0.850 AirCond 12.00 SEER Attic R-8 0.840 LIVING2 Furnace 0.800 AFUE Attic R-8 0.850 AirCond 12.00 SEER Attic R-8 0.840 SLEEPING Furnace 0.800 AFUE Attic R-8 0.850 AirCond 12.00 SEER Attic R-8 0.840 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value 1 Storage Gas Recirc/TimeTemp 1 .51 75 R-12 SPECIAL FEATURES/REMARKS This building incorporates a Zonally Controlled HVAC System. This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. 1) The water heater will require an external insulation blanket of R-12 or greater. 2) This plan requires R-4 or greater insulation on .75 inch or larger hot water main lines or recirculating lines. This is in addition to the insulation required by the mandatory measures. 3) The water heater for this house can have a recirculating pump with a thermostatic controller and time clock, or a COMPUTER METHOD SUMMARY Page 6 C-2R Project Title.......... Rielly Homes - Plan #6 Date........ 11/24/98 MICROPAS4 v4.51 File-RLLY16TS Wth-CTZ15S92 Program -FORM C-2R User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 SPECIAL FEATURES/REMARKS hot water demand type recirculating system. 4) The following rooms will have hard surface flooring: ** Entry ** Laundry ** Hearth ** Kitchen/Pantry ** Nook 5) All glass will be dual pane with a shade coefficient of .70 or less. * All windows will have vinyl frames with an NFRC U-value of .50 or less with the exception of the following, which will have metal frames and an NFRC U-value of .65 or less. ** Rear M.Bedroom Glass ** Rear Great Room Glass ** All Nook Glass * French doors will be metal clad over wood with .59 default NFRC U-value. * Front entry doors will have solid wood frames with .55 default NFRC U-value. HVAC SIZING Page 1 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 Project Address........ PGA West (Job #097-98085)******* La Quinta, California *v4.51* Documentation Author... Rick Maurer ******* Building Permit Rick Maurer Title 24 7544 E Saddlehill Trail Plan Check / Date Orange, CA 92869 714-771-1507 Field Check/ Date Climate Zone.. ..... 15 Compliance Method...... MICROPAS4 v4.51 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 GENERAL INFORMATION Floor Area ................. 3698 sf Volume.. ............ 44859 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ LA QUINTA Latitude... .... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer outside Design...... 112 F Summer Inside Design....... 78 F SummerRange........ ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 23734 12050 Glazing Conduction ............... 25318 22653 Glazing Solar .................... n/a 22413 Infiltration ..................... 23688 15676 Internal Gain .................... n/a 2622 Ducts ............................ 7274 7541 Sensible Load .................... 80014 82955 Latent Load ...................... n/a 24887 Minimum Total Load 80014 107842 x i ► 3 =1 �y,o�8'���• Ham. r3rc, Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. t HVAC SIZING Page 2 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 V4.51 File-RLLY16TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1504 sf Volume ........................... 21056 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 8734 4534 Glazing Conduction ............... 15723 14068 Glazing Solar .................... n/a 11337 Infiltration ..................... 11119 7358 Internal Gain .................... n/a 2460 Ducts ............................ 3557 3976 Sensible Load .................... 39132 43732 Latent Load ...................... n/a 13119 Minimum Zone Load 39132 56851 ZONE 'LIVING2' Floor Area ....................... 331 sf Volume ........................... 3310 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 3896 1727 Glazing Conduction ............... 1378 1233 Glazing Solar .................... n/a 1031 Infiltration ..................... 1748 1157 Internal Gain .................... n/a 162 Ducts ............................ 702 531 Sensible Load .................... 7723 5841 Latent Load ...................... n/a 1752 Minimum Zone Load 7723 7593 ti HVAC SIZING Page 3 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 ZONE 'SLEEPING' Floor Area ....................... 1863 sf Volume ........................... 20493 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 11104 5789 Glazing Conduction ............... 8218 7353 Glazing Solar .................... n/a 10045 Infiltration ..................... 10821 7161 Internal Gain .................... n/a 0 Ducts ............................ 3014 3035 Sensible Load .................... 33158 33383 Latent Load ...................... n/a 10015 Minimum Zone Load 33158 43398 HVAC SIZING Page 4 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 GENERAL INFORMATION FloorArea ................. Volume.. .. .. ............ Front Orientation.......... Sizing Location............ Latitude... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3698 sf 44859 cf Front Facing LA QUINTA 33.7 degrees 32 F 70 F 112 F 78 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 90 deg (E) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 23734 12050 Glazing Conduction ............... 25318 22653 Glazing Solar .................... n/a 24558 Infiltration ..................... 23688 15676 Internal Gain .................... n/a 2622 Ducts............................ 7274 7756 Sensible Load .................... 80014 85314 Latent Load ...................... n/a 25594 Minimum Total Load 80014 110909 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 5 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 1504 sf Volume........................... 21056 cf Heating Description (Btuh) Opaque Conduction and Solar...... 8734 Glazing Conduction ............... 15723 Glazing Solar .................... n/a Infiltration ..................... 11119 Internal Gain .................... n/a Ducts ............................ 3557 Cooling (Btuh) 4534 14068 11543 7358 2460 3996 Sensible Load .................... 39132 43958 Latent Load ...................... n/a 13187 Minimum Zone Load 39132 57146 ZONE 'LIVING2' Floor Area ....................... 331 sf Volume ........................... 3310 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Heating Cooling (Btuh) (Btuh) 3896 1727 1378 1233 n/a 2830 1748 1157 n/a 162 702 711 7723 7819 Latent Load ...................... n/a 2346 Minimum Zone Load 7723 10165 HVAC SIZING Page 6 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 ZONE 'SLEEPING' Floor Area ....................... 1863 sf Volume ........................... 20493 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 11104 5789 Glazing Conduction ............... 8218 7353 Glazing Solar .................... n/a 10185 Infiltration ..................... 10821 7161 Internal Gain .................... n/a 0 Ducts ............................ 3014 3049 Sensible Load .................... 33158 33537 Latent Load ...................... n/a 10061 Minimum Zone Load 33158 43598 HVAC SIZING Page 7 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 GENERAL INFORMATION Floor Area ................. 3698 sf Volume.. . ............ 44859 cf Front Orientation.......... Front Facing Sizing Location............ LA QUINTA Latitude... .... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range........ ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 180 deg (S) HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 23734 12050 Glazing Conduction ............... 25318 22653 Glazing Solar .................... n/a 20307 Infiltration ..................... 23688 15676 Internal Gain .................... n/a 2622 Ducts ............................ 7274 7331 Sensible Load .................... 80014 80639 Latent Load ...................... n/a 24192 Minimum Total Load 80014 104830 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 8 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLY26TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE ILIVING11 Floor Area ....................... 1504 sf Volume ........................... 21056 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Heating Cooling (Btuh) (Btuh) 8734 4534 15723 14068 n/a 10862 11119 7358 n/a 2460 3557 3928 39132 43210 Latent Load ...................... n/a 12963 Minimum Zone Load 39132 56173 ZONE 'LIVING2' Floor Area ....................... 331 sf Volume ........................... 3310 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 3896 1727 Glazing Conduction ............... 1378 1233 Glazing Solar .................... n/a 648 Infiltration ..................... 1748 1157 Internal Gain .................... n/a 162 Ducts ............................ 702 493 Sensible Load .................... 7723 5419 Latent Load ...................... n/a 1626 Minimum Zone Load 7723 7045 HVAC SIZING Page 9 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 V4.51 File-RLLY16TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 ZONE 'SLEEPING' Floor Area ....................... 1863 sf Volume ........................... 20493 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... LatentLoad ...................... Heating Cooling (Btuh) (Btuh) 11104 5789 8218 7353 n/a 8797 10821 7161 n/ a 0 3014 2910 33158 n/ a 32010 9603 Minimum Zone Load 33158 41613 HVAC SIZING Page 10 HVAC Project Title.......... Rielly Homes - Plan #'6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User*-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 GENERAL INFORMATION Floor Area ................. 3698 sf Volume.. ........... 44859 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location............ LA QUINTA Latitude... ..... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range...... ..... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 23734 12050 Glazing Conduction ............... 25318 22653 Glazing Solar .................... n/a 23940 Infiltration ..................... 23688 15676 Internal Gain .................... n/a 2622 Ducts ............................ 7274 7694 Sensible Load .................... 80014 84634 Latent Load ...................... n/a 25390 Minimum Total Load 80014 110025 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 11 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVINGI' Floor Area ....................... 1504 sf Volume ........................... 21056 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 8734 4534 Glazing Conduction ............... 15723 14068 Glazing Solar .................... n/a 10780 Infiltration ..................... 11119 7358 Internal Gain .................... n/a 2460 Ducts ............................ 3557 3920 Sensible Load .................... 39132 43119 Latent Load ...................... n/a 12936 Minimum Zone Load 39132 56055 ZONE 'LIVING2' Floor Area ....................... 331 sf Volume ........................... 3310 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... InternalGain .................... Ducts............................ Sensible Load .................... Heating Cooling (Btuh) (Btuh) 3896 1727 1378 1233 n/a 2830 1748 1157 n/a 162 702 711 7723 7819 Latent Load ...................... n/a 2346 Minimum Zone Load 7723 10165 HVAC SIZING Page 12 HVAC Project Title.......... Rielly Homes - Plan #6 Date........ 11/23/98 MICROPAS4 v4.51 File-RLLYI6TS Wth-CTZ15S92 Program-HVAC SIZING User#-MP0357 User -Rick Maurer Title 24 Run -PGA West - Plan #6 ZONE 'SLEEPING' Floor Area ....................... 1863 sf Volume ........................... 20493 cf Heating Description (Btuh) Opaque Conduction and Solar...... 11104 Glazing Conduction ............... 8218 GlazingSolar .................... n/a Infiltration ..................... 10821 InternalGain .................... n/a Ducts ............................ 3014 Sensible Load .................... 33158 Latent Load ...................... n/a Cooling (Btuh) 5789 7353 10330 7161 0 3063 33697 10109 Minimum Zone Load 33158 43805 2.4 LIGHTING MEASURES Lighting §150(k) Installing energy -efficient lamps and fixtures can reduce lighting energy costs without sacrificing the quality or quantity of light available. As indicated in Table 2-5, a 40 watt standard fluorescent lamp is over four times as efficient as a 100 watt standard incandescent lamp. Kitchen Lighting The Standards require that general lighting in kitchens have an efficacy of at least 40 lumens per watt and be controlled by the most accessible switch(es) in the kitchen. The light switch location determines how the occupant will use the lighting. If more than one set of light fixtures exist which provide general lighting, those controlled by the most accessible switch are considered general lighting. Luminaries used only for specific decorative effects (and which are not the only luminaries in the kitchen) need not meet this requirement. General lighting is lighting designed to provide a substantially uniform level of light distribution throughout a space. This can be achieved by light fixtures in the ceiling or around the perimeter of the room. Lighting fixtures under cabinets may meet the general lighting requirements if they provide uniform light distribution in the kitchen (see Figure 2-11). A luminaire which is the only lighting in a kitchen will be considered general lighting. Bathroom Lighting The Standards require that each room containing a water closet must have at least one luminaire with lamps with an efficacy of at least 40 lumens per watt. As an alternative, this requirement may be met by installing the high efficacy luminaire in an adjacent room that has complementary plumbing fixtures. If there is more than one luminaire in the room, the high -efficacy luminaire must be switched at an entrance to the room. General Luminaries installed to meet the 40 lumens per watt requirements cannot contain medium base incandescent lamp sockets, and must be on separate switches from incandescent lighting. Table 2-5. Typical Efficacy of Luminaries Rated Lamp Typical Efficacy Light Source Type Watts Lumens/Wart Incandescent Standard 40- 100 14 - 18 Incandescent Halogen 40 - 250 lncandescent Halogen IR See footnote sijiivlc Fluorescent Full -Size, 4' Long 32 - 40 69 - 91 (Lamp/Ballast U-Shaped T4 Bipin 16 - 31 78 - 90 Systems)= Compact Fluorescent 5 - 9 26 - 38 Compact Fluorescent 13 + 42 - 59 Metal Halide Metal Halide 32 - 175 50 - 90 High Pressure Sodium White High Pressure Sodium 35 - 100 36 - 55 2 Includes power consumed by ballasts where applicable. Halogen capsule incandescent lamps may be the most efficient light source for highlighting applications. Most halogen lamps are designed to produce a beam of directed light. Manufacturer's data typically list the "candlepower" intensity of that beam, rather than lumens (lumens measure total light output in all directions). ' A new technology using infrared reflecting films on the halogen capsules has increased output up to 30 J lumens/watt for some high wattage lamps. Efficacy of fluorescent lighting varies depending on lamp and ballast types. Mandatory Measures March 1, 19% 2-17 "A" must be fluorescent All of "C" must be fluorescent 1 "A" must be fluorescent "B.. along is not =noral lig:&inv All of "A" or "C" must be fluorescent If "C" then "C" must be the most accessible switch. Figure 2-11: Kitchen Lighting Examples 2-18 March 1, 1996 Residential Manual E V- "A " must be fluorescent "A" or "B'must be fluorescent "A" must be fluorescent; D " can be incandescent "B " or E " must be f iuorescenr Figure 2-12: Bathroom Lighting Examples Mandatory Measures January 1, 1995 2-19 tv1WyL FMAME LUMWOWS = .50 A.)F2C V-VAwe hLd or7i4 I r-rl.AQm A LAoQAJn o W s- 6 M/CAOPAS4 L N L QQ Z S = 5 AJrOIIC V •VALvQ Table 2-2: Manufactured Fenestration Product Default U-Values (this table to be used by manufacturer's to establish a U-value rating without performance testing) Framing Materials Any Metal Thermal Breakl Non Metal (Wood, Vinyl or other) Single Double Doable Single Double Operable Windows 1.28 0.87 0.71 0.92 0.60 Fixed Windows 1.19 0.72 0.60 1.04 0.57 Patio Doors 1.25 0.77 0.68 0.99 0.55H PG Skylights 1.26 0.80 0.70 0.91 0.55 �) Greenhouse Windows 2.26 1.40 1.12 1.94 1.06 �I For all dual -glazed fenestration products �) • Subtract 0.05 for spacers of 7/16" or wider. • Subtract 0.05 for Lowe glazing. NA • Add 0.05 for products with between the panes dividers, if the spacer is less than 7/16" wide. • Add 0.05 to the U-value of any product with true divided Iites [through the pane(s) dividers]. 1. The minimum design characteristics to qualify as Thermal -Break Product are: a. The material used as the thermal -break must have a thermal conductivity of not more than 3.6 BTU-in/hr ft2/'F, and; b. Thermal -break must produce a gap of not less than 0210", and; c. All metal members of the product exposed to interior and exterior air must incorporate a thermal -break meeting the criteria in (1) and (2) above. In addition, the product must be clearly labeled by the manufacturer that it qualifies as a thermally broken product in accordance with CEC requirements. 2. Non metal products can include metal fasteners, hardware and door thresholds. 3. Add 0.04 to the listed U-value for any products that have metal cladding in any configuration. 5 9 Table 2-3: Site Built Fenestration Product Default U-Values (this table to be used to establish a U-value rating without performance testing) Fixed Operable Fuming Materials Any Metal, Including Cladding Single Double 1.19 0.72 Non Metall (Wood, Vinyl or other) Single Double 1.04 0.57 1.32 0.93 0.99 1. Non-metal excludes hardware or door thresholds. 0.55 2�32 COMPLIANCE 711 &92 ©1992 by Enercomp, Inc. )NJT ITfZ -Y ofL3 L10 PO O I A905 ETAL L-AD VMZ 0000 0 IZS MICROPAS4 Figure 2-26: Suandard Shading Coefficients for Glazing Alone Single................ _............................. _.................... 1.00 Double................ _...._...._........ .............. _............... 0.88 these values are from the Table G-11 a in the Residential Manual Figure 2-27: Suggested Names for Interior Shading devices Description Interior Shade Drapes.Std Non -white drapes (CEC Standard for windows and French doors). Drapes.Wht Drapery with a white or off-white liner None No interior drapes (CEC Standard for skylights) Blinds.Med Medium Colored venetian blinds Blinds.Lt Light-colored venetian blinds Roller -Dark Opaque, dark colored roller blinds Roller.Wht Opaque, white interior holler shades Roller.Lt Translucent, white roller shades Special Interior shade not represented by the types above. Table 2-7: Shading Coefficientsfor Interior Shading Devices Alone(Shades Close j Drapery: Standard.............. _... _...._..... _.............................. 0.781 WhitelOff--White.................................................... 0.62 Venetian Blinds: MediumColor... ......... ...... _................................... 0.63 LightColor............................................................. 0.58 Roller Shades: Opaque Dark.................................................................. 0.81 White........................... ...... .................... ......... 0.402 Translucent Light................................. _..................... _....... 0.44 1. 0.78 is the default value used when there is no interior shading device installed on vertical fenestration products. 2. No interior shading device may be given a shading coefficient value lower than 0.40 Note that the values above are from the row labeled 'Interior Shade' in Table G-11 a in the Residential Manual 41.E LASS W)LL BF DVAL ,k"A rAAjE w)Tm A sNAn s GO EFF) C) EX) r OF s "7a nfZ LeS S + QLA. ry s MI rAL. r-i2x�nF_ • F EV &_ T>M Y_1pn O N `i ro 13 E 2-42 COMPLIANCE 7116192 1992 b SEne p, Iw E 2 Y r lnc. D E10U i4L� 4 . Table G-16: Standard U-Values of Wood Frame Roofs and Ceilings; Ceiling Framing Reference Imsul. Sparing Name2 U-Value R-03 16" o.c. R.0.2X6.16 0.299 R-03 24' o.c. R.0.2X4.244 0.306 R-113 16' o.c. R.11.2X6.16 0.077 R-113 24" o.c. R.11.2X4.24 0.076 R-133 16" o.c. R.13.2X6.16 0.069 R-133 24' o.c. R.13.2X4.24 0.068 R-19 16' o.c. R.19.ZX8.16 .051 R-19 24" o.c. R.19.2X4.24 7 R-22 16' o.c. R.22.2X10.16 R-22 24" o.c. R.22.2X4.24 0.041 R-30 16" o.c. R.30.2X10.16 .0 6 b R-30 16" o.c. R.30.2X12.16 R-30 24" o.c. R.30.2X4.24 $.OB29 R-38 16" o.c. R.38.2X12.16 R-38 16" o.c. R.38.2XI4.16 0.028 R-38 24' o.c. R.38.2X4.24 M R-49 16" o.c. R.49.2X4.16 0.019 R-49 24" o.c. R.24.2X4.24 0.019 I. Based on ASHRAE Parallel Heat Flow Calculation, 1989 ASHRAE Handbook of Fundamentals. 2. The names given to the standard assemblies used to calculate these U-values in Appendix H. 3. Does not meet the minimum level required as a mandatory measure (see Section 2.2). 4. Roof/ceiling assemblies whose reference names list 2X4 framing include an attic space. G-54 Table G-17: Standard U-Values of Wood Frame Wailsi Wall Framing Reference InsuL Spacing Name2 U-Value R-03 16" o.c. W.O.ZX4.16 0.386 R-03 24' o.c. W.0.2X4.24 0.393 R-73 16" o.c. W.7.2X4.16 0.130 R-73 24' o.c. W.7.2X4.24 0.127 R-113 16' o.c. W.11.2X4.16 0.098 R-113 24' o.c. W.11.2X4.24 0.094 R-13 16" o.c. W.13.ZX4.16 0.088 R-13 24' o.c. W.13.ZX4.24 0.0 R-15 16' o.c. W.15.2X4.16 OSI R-15 24' o.c. W.15.ZX4.24 0.077 R-19 16" o.c. W.19.2X6.16 0.065 R-19 4' o.c. W.19.2X6.24 0.063 R-21 16' o.c. W.21.2X6.16 PO5 R-21 24' o.c. W.21.2X6.24 R-25 16" o.c. W .25.2X6.16 0.046 R-29 16" o.c. W.29.2X4.16 0.035 Solid core wood D.O.SCW 0.330 door (no insulation) 1. Based on ASHR.4E Parallel Heat FIow Calculation, 1989 ASHRAE Handbook of Fun.dame=Ls. 2. The names given to the standard assemblies used to calculate these U-values in Appendix H. 3. Does not meet the minimum level reuuired as a mandatory measure (sec Section 2.2). January 1, 1995 Residential Manual Table G-18: Standard U-Values of Wood Frame Raised Floocsl Floor Reference Insul. Condition Name2 U-Value R.03 No C.S.4 FXO.2X6.16 O,-ilg R-03 With C.S.4 FCO=6.16 0.097 R-113 No C.S. FXII.2X6.16 0.071 R-113 With C.S. FCII.2X6.16 0.049 R-13 No C.S. FX13.2X6.16 0.064 R-13 With C.S. FC13.2X6.16 0.046 R-19 No C.S. FX19.2X8.16 .048 i R-19 With C.S. FC19.2X8.16 .037 R-21 No C.S. FX21.2X8.16 0. 5 R-21 With C.S. FC21.2X8.16 0.035 R-30 No C.S. FX30?.X10.16R03p R-30 With C.S. FC30.2XIO.16 1. Based on ASHRAE Parallel Heat Flow Calculation, 1989 <ASHRAE Handbook of Fundamentals. 2. The names given to the standard assemblies used to calculate these U-values in Appendix H. 3. Does not meet the rninimum level required as a mandatory measure (see Section 2.2). 4. No C.S. = No Crawl Space, With C.S. _ With Crawl Space Glossary Table G-19: Standard U-Values of Wood Foam Panel Roofs/Ceilings and Walisl Roof/ Ceiling Framing Reference Insul. Spacing NameZ U-Value R-143 48' o.c. RP.14.2X4.48 0.064 R-22 48' O.C. RP.22.7-X6.48 0.044 R-28 48' o.c. RP.28.2X8.48 0.035 R-36 48' o.c. RP.36.2X10.48 0.028 Will Framing Reference Insul. Spacing Name U-Value R-14 48" o.c. WP.14.2X4.48 0.071 R-22 48' o.c. WP-2 .2X6.48 0.0-19 1. Based on ASHRAE Parallel Hest Flow Calculation, 1989 ASHRAE Handbook of Fundamentals. 2. The names given to the standard assemblies used to calculate these U-values in Appendix H. 3. Doss not meet the minimum level required as a mandatory measure (see Section 2.2). January I, 1995 G-55 „Zro> MEAT/PUMP T14'E12M0STA7S (b) Controls for Heat Pumps with S=lementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters shall have controls: I. That prevent supplementary heater operation when the heating load can be met by the heat pump alone; and 2. In which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. EXCEPTION to Section 112(b): The controls may allow supplementary heater operation during: I. Defrost; and II. Transient periods such as start-ups and following room thermostat setpoint advance, if the controls provide preferential rate control, intelligent recovery, staging, ramping, or another control mechanism designed to preclude the unnecessary operation of supplementary heating. July 1, 1995 36 ZONAL CONITROL 8.9 ZONAL CONTROL A procedure for analyzing the energy impact of zonally controlled space heating and cooling systems has been approved by the Commission as an exceptional method (Commission approved according to Title 24, Part 1, Section 10-109 based on Compliance Options Approval Request, May 14, 1985). The method is available as an option using the point system (See "Heating System" and "Cooling System" in Section 4.2) or using a computer performance approach and specific modeling criteria (Section 5AL). There are unique eligibility and installation requirements that must be met in order for this zonal control method to receive conservation credit. The following steps must be taken for the building to show compliance with the Standards under this exceptional method: TE.IOERATURE SE NSORS Each thermal zone, including a living zone and a sleeping zone, shall have individual air temperature sensors. HABITABLE R OO:,WS Each habitable room in each zone shall have a source of space heating and/or cooling (if zonal credit for cooling is desired) such as forced air supply registers or individual conditioning units. Habitable rooms shall not include bathrooms. laundry, halls and/or dressing rooms. NONCLOSABLE OPENIVGS The total nonclosable opening area between adjacent living and sleeping thermal zones (i.e., halls, stairwells or other openings) shall be less than or equal to 40 square feet. All remaining zonal boundary areas shall be separated by permanent floor to ceiling walls and/or fully solid operable doors capable of restricting free air movement when in the closed position. SETBACK THERMOSTATS Each zone shall be controlled by a central automatic dual setback thermostat which can control the conditioning equipment and maintain preset temperatures for varying time periods in each zone independently from the other. 1. Each zone must have automatic dual setback control for heating and setup control for cooling if cooling is provided. 2. Thermostat locations in each zone must provide accurate temperature readings of the typical condition in that zone. 3. The control may be switched from heating to cooling mode manually. 4. The control must be programmable by the occupant. 5. For residences using heat pump systems, the automatic setback thermostat must have two - stage heating which incorporates a recovery ramp of other logic that will minimize electric resistance heating. FORCED AIR D UCTED SYSTE.,WS 1. Each zone must be served by a return air register located entirely within the zone. Return air dampers are not required. 2. Dampers shall be manufactured and installed so that when they are closed, there is no measurable air flow at the registers. 3. The system must be designed to operate within the equipment manufacturer's specifications. 4. Air is to positively flow into, through and out of a zone only when the zone is being conditioned. No measurable amount of supply air is to be discharged into unconditioned or unoccupied space in order to maintain proper air flows in the system. 5. Systems that allow supply air to be bypassed to the return air system shall be protected against short cycling and excessive temperatures of the space conditioning equipment, and include necessary controls for efficient, safe and quiet operation. T1---------- 7li i......... 1r 7 7; SL 40 -owl it a w - - --- ------- ------- --------- T t7 : 2 T 86 i 9T =33 _.-t-:31 Liv) --------- ..w.l...e. w...... n 4 ; -------------------� i 4 I I ` rw •M SIM t y �.. t W&P I .w�...r..-. •ip rsww it MOMt 1fMMal kwM 1W�0Y� —_ I . r ( ► Qg4Lj i I I� • I I ;! I i' ' .ice �.rwowo. ,.—. � • I 1 I I I I I I I , I I I , I I I�I S I 3b 9 r .�3S I � ► a -_- --- -i � s I Y 1 Vjs {t! 35 lit I •------------------ _ --• __ ll/1�� 1143 � a 86, 9t dSS 'O, f � 3 ..� $Dill I --------- �— >! �+mwmoe 9 I I I a�11 i I I t b1£ f £ I I I I 1 I f 1 I a I I ► ' ' I I I I I I I I I � I I I I I I I I 1 � I 1 I I I 1 1 1 1 I t ,-4 y lag a' _"'' pLA� S� • 1 � �� � tST• TIIJ i � pii D� 9� a sZAS ---- F ---- asi kb M L I bb Lt 36, 9I .3M LO/13 -j CD78 _—IrI09y-1 flyI OSSH-g r Ll �a D «mac t2l ........... Ems.t rm' mi ►� At HiyIN33b�"3 3t''z-Cl _»-t-7 -"> w• Sb 35. 9L :13S :©ca _,8 �H-rFi1:=1H� F.IHIAI.C_�� - - - - - - - - - - I j rr_. r _ r PLAN : 1 GLAZING AREA11 & =. ov/= �iooa �'YI.i3R. LbX S = 1Z.Sr�x M,Y3a !�rbf, fi-m. loxIo - !00 s60 o !�04-. rwn . t0'y 9 = 1�0 r-1 x i� ar aw . S X--y 9 0 (01=1 x M,Z yXL= c� C�XSsyr��� eel L +o)tS= 30 Zyy Co1.5,, I 70 Z ) )3 6151.1mr. SKYLIGWTS a 4:;,rL . /ZW7, Zy L= )LI3)r--vx y�.6,0, Zxt= /2-13)PiX 13 A . 44 � y, s = L Z , S r-i 7 i3 -A4 . z x 3 = (o Ft X Yn . r&�i9 y G L = 9 Ve^,16n. 3 coxg = Y Sba 1:2!1 PZ , Z k OV 7-, (o x 8' = 9 $ it-) F T. Ery -r. EDIV T. (o )t L = 1214" ` x K 4-t, ►. 3 x (o ' 5t1 C31 GARACaE TOTAL Gi.AzIWG = Ca Cry 3 y PLAN* Z 9 GLAZING AREAll rn 1p__ rneTn'11 Gt-vow of wQor3 yr! . pia%, ) Z m.r30P. x = 36 Gig a W-1g0, Xl0 = n sbo (D X 5 S T►?� IY c� o I� g �c ► $, ��T, Z,�z� IZf3is:1X L + 3 xq =)1- L�VJOY q - �Q FIY bIN, i0X(O =10036"v no0L gxs NOaK $ X I = $ C49'5) I 2 y T7 j l q� Q S 60 Z Y � Z lLo7 t3l? = zy $3 /1,00le- ram, t3r�. m- 6A r».,3r1, rm. rbr 7,A'S 3 X 5= 1 S GP517� Z t-q = $ 6A-3 SICYLIGHTS O 3k =2-9 L4 L4 g•V , x9f= L) -5Uc, (oYs s7D) car, 3Xb = 3�ttl r-, PI u r . tic? GARAGE TOTAL_ GLA7..1NC, = 7 31,E o AN : .� L.AZINq AREA Z119S t32.I = ZSl� = vW 00057 s/q. L L x-:b= e S WYLIQ14TS rl7lad. )0/-i•p =) 00 S649 0 nonn, (o X (a = 3 a x (S Tn 10 )t 9, Ft �) . �n,;r n,,+� , 10 x 9 = 9 0 F- X x = by s(0o 2Crr x S s rv� G IAS $ Tom" S - 7. 3 = la As /4 . Ly 7rzr.2r'l .*0,10YIc) =1oOSb,a � �ro5 tax? --LOB s�-v c ,4rW b !� 3 X (0 kf&t,` 5��' G Y}S i Tq' S o0' 3 3 x S= 3 0 l ti) G r5 i 7S '619.2 g- 0 0 rY7.60, Sx t = !b �X n7 -13i4 . Z x 3 = 1 e (-;,) m-c Fj X i�i?N�i3�,L dX�= 4S'SSoO 3kS=ISF-1 �C 3x5 r1,00X 8-X $ = (oy S6o i• L� b = LqIt) PVC O i " T- , fD Y- s 4 S- (t j r-j'4 7. C7v7 d OCI�S v R� GARACME TOTAL G:.Aziuc, 5 P�2e f II GLAZING AREA 11 o rq eM, )0x8 = AN0 ' 3 Z -LZ $-� u Z t Z- r-, y ®- Y-Y, T'Q''- b _S KYL1QWTS = )ne Tw- L� n�Is.toop o L1 V/,vl ri. = 7 L F1 X O j �\AJC70* L-)V, x g = .71- 1=1x ,ayr,60, �x � o = uo s �0 —� ��° x � �� o� ��ti ATV) V,e,T (px.-L-=)L 2-ar, COY Ry rxs sm� - 1 t � s I Tr-4-5V X Y " `7 A05 ► TAS Z- 1-3 = (o 6,4. W Pam � � 3 � g F. � Z � ,L .,on, 2, 2r �x= � 3� �� a �T-. �1, !�0 rn: rye• 3 = ) L �t ) �y1 Y3 A Z Y � 0 5 Va !Z le7' cL 60 , 3 X Fr r-Ot?-i'n t 3 A-O O Ic (o yc Ll ry /1/0 o I-e- 7. = L r x S I T, J lox � �e113ev. 3 S x 5- z 5 13�'�3 Zvi =ko H is L L Z LD �N T. x q {E5�v T-, (o X '? GA- 5 I t b Y- c GARACaE TOTAL. GLA7.1 NCB = % 0 (9 �% Y PLAN' S II GLAZING AR-EAII e 1:4w - gxiq = aosfvo s �_ � C' ?)4't � le - me x = wooer (S )L S s T-O ---> 3 Y O 9 154c 303b t373 = 3Y09 A' o to d �&P)L _ ICYLIG,HTS 14XI� = 10056� O lox 0 L.l V. t 0 x 9. 9 0 Fi X Fes•• gx`? FPYr l. 9 gr x= F,q'm yFit,vA F' 'M 3 = 5 4,,' F! x co L = (o Ply i)2T' (oX 1 =t1 ea-f• � nor• to u45 i rok*-s 2x S = to 2 bd y Z(QZ� Y s 5-o aer• C(p X to Pi x o/ to X L s TO u0 Sao a T- Zx3 = Z9 (q) F-IX ����/3r�• 3 (,)A 5= 3 0 ap, ) ?(3) ;=,-4 h�,j3l�, 5 x 10 = 30,Gty_ xact) r� gyp, sxt = In m • � 14 Z � 3 = I � (3) r_l FYIJ T � 3 x y = z 4 1�l ��-� FL'/ OJT, U = Ly 1�lN. 3 X'(p =�$ GIB ,t�i�✓3 x(o= I � L-AV N. 3 X = I Z E?vT- L X GaaA.GE pix, �V` TOTAL GLAZ.INC. = ` Z5 `� y II GLAZING AREAll t = r l e-T)4-L ReZ41--k r4 eTR'L c-%. Iqw d/ wodo U via0,0 3 e 9 �? 5Q,Fr. 33b7t331 ° 364� 0 r>'J . f3,d , S- x < <3 = FAO s 6 a t-(6 x 8 5.10) 6v , S- x ?- b y F-1 x S KYLI WTS r-l-A,!5 TV,) ® 111(20X- )0 x1 = 10 4 r-1)4 A4 0 L= 8' X 8' = fa y rt x o rW b k- ?r X A = 5 A4..,.- Fi 14 K1T. ZX L :: %(oty)F-1 f- -c- L Ll4 (Z) �3I-V, 3 5x 5 - ZS Z N Frr, ate, W-P 1 q9 ,5,. 1,9q, �`�Ssto) S6� "OK Skl ry n a V— $ X 1 = Fz er7� )3a, C l<l'S i 1 r-r. Ll N S = I-Q �A-5ir1-5 )eX3 = 9,s �x v PNleA. y X S s Its, ron, J lx q(= e O O^jT coy 0= Y P ft-) Fr'Zr vr. 1.oc s Er\j T Aj- OP. owe 5X'l- TOTAL. GL.A7.IWCq � � o cy �o . E O UIPMENT(om squ, :. RIEE�t-Y i-{pmES A.MEIZIGAM WAzErz KEa-E2 WSST'. LA Qvl�rd lr= -lc 4E .A v, IU P L A ICJ I LIV1W SLEEPIN FLOW C as FAU --� — �¢cz. CAS FAU 5OU�A3-Ia0 8C%J�H3-100 iF�-Ow 6,Ar7 FAU - CO. FAN/COIL. — — AFUE Blu _ OUTPUT y°I,Zoo L1912po cr-m IZID IZIO STRIP 14 EAT �- 2T, COO>'A' COIL. — KZl-Z C00".CO« r-HZ3 -y I GHZ3 -Li I :AT Pu►.,Ta uN,T - >NDEN51N6; UNIT �ZAGP�•3(a �Zp,�p,.?j(Q KSPF (MIM.) — SEETZ (MIN.) �20 120 TONS 3 3 s1�s� 115° zS,s�Z ZS,sOZ C�ALI.ON�j -%S BlUH INPUT -7Lj 1SZ1c) REC, EFF1G. 7(0 %o STAmo-BY•LD5� 0/4, ENEUY PAC= .51 TANK .w1ZAP 'Y ES -1 Z CTS-4SULAT10W Q-60 � M'4IT SET- SAC" 7HEnMOSTAT4 ADZE_ MEqu l asa . � T1-MMMOSTATS wl ,57m 1 p 1-1 EAT FU N GT 1 v N MUST MEET THE 2 E4 Mom. OF SEGZ-I fl N # 11 Z (b) OF 199E EIuETZyY STA K%VACZ DS . �- L1V11,1G / SLEEPImr. 7nt-JA.1_ r-nk l i % rli dcenii E QuIPMFmNT(om Ezqu,� a[EL- -:1 Homez-7 A"E21CAtQ WA.zF-n t,-kF-a-S2 `� PC-� A► \14F,6T" LEd,440y cc. HEAT1►�l A j� LA. q u t lure. PLAN 2 I , J P FLOW C;a.S FAU P0¢17. (�A.S FAU 'NFLow FAU 15T Co. FAN/ColL- AFU E BTU _ OUTPUT CFM STRIP ! FEAT /�.�-, COOL;, Co l l- 4orziz. Coo".Coii. 4 EAT f Pure U V4rr �OkVENSIN4� UtvtT KSPF (Mlt�i.� TONS arru ��@ 9s° srvs e 115O �IATEa K��.r�z CIALLONS 5WH INPUT REC, EFF1C. STAm o- By- Lo5ci ENF-a4y FACTOR. TANK wgAp )UCT 1,4SUL,4710W SO U44 H -15 So% (o 11-70 0 1 (o00 cHZ2--)-5I IZ.ACS-Hz 1Z.,D 3'/z. y 1, 500 3Z) C OLi �Ovt�µ3-(o0 Rio lzlo 12 AGC3 -3la 3 351(a 00 251502 laouyk 2•45 5o% 340,9o0 990 {CH23 -B I �2,e,ct3-2� i �52.-75T75-4tJ -75 H 1 500 %(o °/o 11/A .51 yE5 Q- IZ. 12 - la )2.0 2 za3 $ o0 15, 500 M14AT SET-5Aa" 7HSaMCSTAT4 AiZE. QEqut2ED. Ti-1ETLMOSTATS Wl SiTZI f� HEAT FU1JC.1'1 ON MUST MEET TNE. OF gEGTI Q N l l 2 ()=) OF 19,9E E�vEV�y STA,iVi7A TZ DS . l_l�l1NG I SLEEPlI�Ir 7-01j,&_ Gn►-I--+Anti ncr-i si#-7= , 2 Sp MT`o. RIEE_LL-y Hom 5 "PC1 A. WF,6T" LA, q U t hjrA. , RFLOW Gas FA.0 4 cMtZ. (�Q4 FA DNPLOW ClAr, FAU IST CO. FAN/COIL. AFU EF BZU _ OUTPUT CFM 5TR1P SEAT /F-�.T, COOL.,;. Ca IL 4omm . COO". CC I L. -1EAT Pump Uw-r �ONDEtaSlN6f UMiT SEEM TONS arr j a. @ 9 E o Sews e 115o VAiER HEATVM C4A LLON4j 5-TU H IN PUT REC. EFFtC . II STAklO• SY• LD5ri ENF-24y FACTM TANu WRAP ?u,cT T-wSULA-T10W EOUIPMENTcoa E,,,,� A M E-21 CAN LEtIMOx cc. PLAN 3 1�SLEEPIIJG I c 50%D lolJ-?Oo 1(00 0 Ir-HZ3-51 IIZ.,&,c>o -Li8 IZ,O H LA-71 SU o 35,9 y 5 IZ.0 3 Vz- H I, 500 3Z,Ooy 8Of`at�H2-�5 s0% 31a,900 990 CHZ3-31 (;5'z-75T-75- H N 75 7y, 'Boo 7 LG'2/ o Q14 .51 YES 12.-17- Q-�& WAITF-rz HF-Axs2 H EATI N GI j A/ L M'4AT SET- P$AC" 714SUMOSTATS ARE. IzEQu l2E0 . Tl4SM,i1OSTA.TS w/ S7R1 P HEAT FvNGTI ON MUST MEET THE OF SECTION # 112 (b) of f99E Ek�EII1�y STAMtpA ZCe � (—IVlt..1/ /�►-�1=A11�1� ��ti,�i �r�. rrr�r,ti t��..--,...mot-,r. Q EQ MTS. E 0 U I P M E N7 (o;z P,[E4 -Ul HC)ME5 "PC1 A \,"'E5T" LA QVINTA. p L1vING J Q FLOW Gas FAU P02-17. CjQ4 FAU DNFLOW rgAS FAU IST CO. T=AN/GolL. AFUE BTU _ OUTPUT cFM STRIP 14EAT PERT, COOLC;. COIL -4021Z . COO I.C. CO1 L 4sAT f PuMta UNi-r :�ONGEM$IN41 UNIT HSPF (MIN, SEEI`L (M I P1.� TONS aru ti @ 9 s' saws p 115,0 VA -TER H F—.&,TSTL (�AL.LONe7 Blv H IN PUT REC, EFFIC. STA M 0 - BY• L 055 ENF-24Y FACTM TANK WyZAP 1UCT TijSUL,, TIOW ou�1-4415-Inc SO% 82.,pOc� z zc,7o CN Z3 -CoS 12,0 5 .67, 00� I-13, 2 9 !o A "F-IZI CANA LEl,ImCy Gc. A N H _EE I N CAS 50UJKL1--75 50% (01,-700 R000 cHZ3-5� 12,0 y y�, 500 5 519 4 5 8OU4t42-45 80% 3to19o0 990 cH23-31 ,12Qce -2� 12, o Z 23, 80o 15, 500 ci5Z-?5T-75-4N 75 7L4, 500 7 Co °/o N/A .51 YES 12-IZ V--o WA.i F- Z HEhT S2 14 S-471 )-4 (;j 4 A/C. N14HT A¢F ZEgUl2Eo. Ti 41=1ZMOSTA•TS W/ STfZ I F HEAT F'v N GT 1 O N MU 5T MF-Mr i'H I= or- 'S�aC:710N * 112 ()=) OF 1995 SKISCyY STA %Al2AiZDS. E Ll v l t.1 G -7r--n jd t _ -- r-n ri-r rn ► 2 4 m7t7. EQUIPMENT(cm F-quAL) RIELL-:1 1-TOMES AMtEPU GANI WA.F-R rr PCB A. BEST" LE1alt�1 OX GO. H1=A.Tt N G1 ,4�c. 1_A q u t terra. PL AW 5 U P PLOW G&ca FFA.0 P02E7. (:�Ac; FA DNFL-oW C3A5 FAU 15T CO. FAN/GotL_ AFU E B- U . OUTPUT GFM 5WI9 14eAT ✓F-RT. (:OOLl1. Cc 11- Holz Z. coo".Cotl. -TEAT ! Rum? UNIT —okoEKSPItg6 UMIT lAS;PF ("IM.) SEECL (M I Q.) TONS aTu",A.@ 9s° sFis 115° &/ATER H E A.Ts-a (:4AL-L-oNS 5WH INPUT REC, EFFIG. St'A M 0- BY• L055 EN E>4Y FAcTCQ TANK wiZAp )UCT TiASULA�'I0W L VI Live I80U�H3400 I &DUJ14-3-(,o0 BO% L491200 1210 IcNZB-L!1 a0% ° 49, Zo0 1210 .F-EPING u�W4-75 g% 61,-700 1(.00 IGNZ3 -51 12�,ct�-3ca,12�.cC3-3(�a,I2aGg-�j 2 3 35,Cot�O 25,SDZ ! Z.D 3 Z 5, 57 Z c,52-75T75-H N 7E5 7y,soo 7(o N�A DES �1.-1Z GAS 1 T4 80u6, H 2-�f5 Soho 99O ct.t 2� -31 M14-kT I -VAS- MOS;TATIS, A¢E. 2EgU12ED. T;-lERMOSTA►TS w� STIZt fl HEAT FUNC-TION MUST MEET 7H1= 2EPtvM-7. O� �EGTI fl N # 112 (b) o F 19 9 5 EiuE�Y STAniDA,tZ DS . E LIVfNG /St_��1t..dr Zc3l.sdt_ r-nws-rprn o��t ,�n�-, EOUIPMENT(ozz eti,� lZELLY 1-10NtE5 AMEIZIGAty WATER-IEbT�Z P , a• LAl PLAN (o U P Ftow Gas FAU Pamlz. r4AS FAU DNFI-oW (�A�, FAU 15T CO. FAN%Go1L AFU E BTU _ OUTPUT. GFM STR1P MEAT VF—!Zr, CaoL,A, Ca tl- woma . Gao". r.011. 14E4T I PUMP UNIT CONDEM51N6 UN1T KSPF (Mltl.� SEER (M I r.1.� TONS aru ti @ s° sEus e 1 IS" �A/AiER H E,&xi iZ GALLON�j 5TUH INPUT REC. EFFIG. STA m v- i5Y• LD55 ENEII4Y FACTOR TANK .WIZAP DUCT Ii.ISULAi'10W eou�HH/5-100 80jo iaz,fl00 2.7440 c1-I Z ?:) - (05 1Z.4 5 57,000 y 5jzc?!o 80ur�N�-� 5 60/O (01,700 1 (000 c.i,-t Ll - 51 1ZAcs-46 lz,o y 47,E500 -3s9415 V� .k 2-L45 8l7°/0 3(,:P,900 990 12�Q 2 2 3, BOO 15, 800 6,52-75z75- y -75 ZyIf 500 7Co /V .51 YEs Tz-1 z 12- S * NI414T SET -BAG" TIASMmos;TAT4 AaF_, ME4pulaso. �K THEAMC-5rXTS w/ SbM1P HEAT FJNGT1oN MUST MEET 7-,4'E. OF SEGTI fl N I I Z (b) o f 1°t9 E1vE>�,y STAnIflA►rC7e. �k LIVINCG )SL-EEgjto/, 717N..1_ /-nKrrvtD1 12,F=fot jrrr-, I m9 MTS. lma/" ENGINEERING DATA UP -FLOW POSITION GAS FURNACFES VALUE 80TM 80UFHG UP-PLOW/HORIZONTAL GAS FURNACES Bulletin No. 210215 *80.0 to 80.5% A.F.U.E. November 1997 45,000 to 120,000 Btuh (13.2 to 32.2 M) Input Heating Capacity 1-1/2 thru 6 Tons (3.5 thru 21.1 M) Nominal Add -on Cooling Isolated Combustion System Hating for Non -Weatherized FurTraees p EslaAr R C c.ue an.w GAS _ amai �rro A �fRTlflt� �.► Typical Applications Up -Flow Utility Room Installation With Cooling Coil and Automatic Humieifier FEATURES Applications e80UHG series gas fired furnaces include ten models (natural gas or LPG/propane) with input capacities of 45,000, 60.000, 75,000, 100,000 and 120,000 Stun (13.2, 17.6, 22.0, 29.3 and 32.2 kW) *A.F.U.E. up to 80.5%. * Up -flow or horizontal applications. *Lennox add -on evaporator coils, electronic air cleaners and power humidifiers can be easily added to the furnace. *Units are shipped factory assembled with all controls installed and wired. *Each unit is factory test operated to insure proper operation. Tubular Aluminized Steel Heat Exchanger -Constructed of aluminized steel for superior resistance to corrosion and oxidation. *Curving design allows com- plete exposure of heating sur- faces to supply air stream. *Round surfaces create mini- mum air resistance and allow air to surround all surfaces for excellent heat transfer. *Compact design reduces space requirements in unit cabinet *Heat exchanger has been laboratory life cycle tested. HORIZONTAL POSITION H1' Normal Attic Installation With Cooling Coil, Eecconic Air Cleaner and Automatic Hurnidifier Approvals *Units are certified by A.G.AJC.G.A. Laboratories *Ratings are certified by GAMA. *Units have been rated and tested according to U.S. GCE test procedures and FTC labeling regulations. *80UHG "X" models meet California Nitrogen Oxides (NO,) Standards and California Seasonal Efficiency requirements. *Blower data is from unit tests conducted in the Lennox Labo- ratory air test chamber. *Units are approved for conventional or horizontal (sidewall) venting. NOTE - Horizontal venting requires sidewall power venting kit. see Optional Accessories. Equipment Warranty *Heat exchanger - limited warranty for ten years. *Solid-state ignition module - limited warranty for three years. *All other components - limited warranty for one year. *Refer to the Lennox Equipment Limited Warranty certificate included with the equipment for details. Induced Draft Slower *Induced draft blower prepurges heat exchanger and safely vents flue products. *blower is controlled by the furnace control center board for a pnepurge cycle (15 seconds) and a post purge cycle (5 seconds). *Pressure switch proves blower operation before allowing gas valve to open. -Induced draft blower operates only during heating cycle. NOTE - Oue to Lennox ongoing Comm ntnent o y 1997 Lennox Inousmes Inc. 9 9 duality, Speafications. Ratings aria (Dimensions suo+ea ;o rnanoe wmn,r rwftnp anti w rtwe im mm,n -� '%, SPECIFICATIONS if 1 Model No. 80UHG2(X)-45 80UHG3(X)-60 80UHG2-75 80UHG3(X)-75 80UHG4(X)-75 Input Stun (kW) 45.000 (132) 60,000 (17.6) 75.000 (22.0) Output Stun (kW) 36,900 (10.8) 4.9.200 (14.4) 61,700 (18.1) A.FU.E 80.1% 80.5% $0.1 a 80.0% California Seasonal Efficiency 75.49% 76.4°o i5.9% 6.8°'c 76.8% 76.70 Flue size connection diameter . in. (mm) round 3 (76) 4 (102) Temperature rise range - ' F (IC) 30 60 (17. 33) _ (25 _ 4� High static certified by A.G AJC.G A. • in wg (Pa) .50(125) Gas Piping Size I.P.S. Natural or LPG/pmpane 1/2 (13) Blower wheel nominal 'n• 9 x 7 10 x 7 9 x 7 10 x 7 12 x 8 diameter x width mm 229 x 178 254 x 178 229 x 178 254 x 178 305 x 203 Blower motor output - hp (W) 1/4 (187) 1/3 (224) 1/4 (187) 1/3 (224) 1/2 (373) NOmina) cooling Tons 1, 1-1/2 or 2 2, 2-1/2 or 3 1, 1-12 or 2 2. 2-1/2 or 3 Z 2-112. 3. 3-1/2 or 4 that can be added kW 3.5, 5.3 or 7.0 7.0, 8.8 or 10.6 34 5.3 or7.0 7.0. 8.8 or 7.0, 8.8, 10.6. 10.6 1Z3 or 14.1 Shipping weight - lbs. (kg) 1 package 130 (59) 135 (61) 140 (64) Electrical characteristics 120 volts - 60 hertz - 1 phase (less than 12 amps) AN models Optional Accessories (Must Be Ordered Extra) -- LPG/propane kit LB�9845L (38K84) Twinning Kit 96,169 - 5 Ibs. (2 kg) Up-Fiow/Honzontat Filter and Filter Rack Kits .MNo. & size of filters - in. (mm) Single (32J02) Ten Pack (66K64) (1) 16 x 20 x 1 (406 x 508 x 25) Sidewall Power Venting Kit 79,115 - 25 Ibs. (11 kg) Hanging Bracket Kit L.8-69957 (46J66) - 15 Ibs. (8 kg) ]2Annual Fuel Utilization tifioencv ❑asan tin I i c nnc _lroryuremane Name type filter is tumisned with kit -- -- r -�� _ ro -Ieywauais Isomea comousoon sysism r3mN for rsornwear*rized f imacas. Model No. 80UHG3/4(X)-100 80UHG415(X)-100 85UHG3/4-120 80UHG4/5(X)-120 Input Stun (kW) 100.000 (29.3) 120.000 (35.2) Output Stun (kW) 82.000 (24.0) 38.400 (28.8) A.F. U. E 80.1 % 30.0% 80.1°b California Seasonal Effiuency 76.5% 77.0'v Not Available 75.5% Flue size connection diameter - In. (mm) round 4 (102) Temperature rise range - ' F ('C) 45 - 75 (25 -12) 35 - 65 (19 - 36) 45 - 75 (25 - 42) High static certified by A.G.AJC.G.A. - in wg. (Pa) 50 (125) 65 (162) 50 (125) Gas Piping Size I.P.S. Natural or LPG/propane 1/2 (13) 12 x 8 12 x 9 12 x 8 12 x 9 Blower wheel nominal in. diameter x width 305 x 203 305 x 229 305 x 203 305 z 229 mm Blower motor output - hp (W) 112 (373) 2 2-1/2 3, 3-t2 or a 3/4 (560) 3-1/Z 4. 5 or 6 12 (373) 2, 2-1/2. 3, 3-1/2 or 4 3/4 (560) Nominal cooling Tons 3-1/2. 4. 5 or 6 that can be added ky� 7.0. 8.8, 10.6. 12.3 or 14.1 12 3, 14.1. 17.66 or 21.1 7.0. 3.8, 10.6, 1Z3 or 14.1 12.3, 14.1, 17.6 or 21.1 Shipping weight - Ibs. (kg) 1 Package 175 (79) 120 volts - 60 hertz - 1 phase (less than 12 amps) AN models Elecutgl characteristics Optional Accessories (Must Be Ordered Extra) LPG/propane kit LB-69845K (81J74) Twinning Kit 96,169 - 5 Ibs. (2 kg) Up-Flow/Honzontat Filter and Filter Pack Kits iZNo. & size of filters - in. (mm) Single (46J14) Ten Pack (66K65) (1) 20 x 20 x 1 (508 x 508 x 25) Sidewall Power Venting Kit 79J15 - 25 Ibs. (11 kg) Hanging Bracket Kit LB-69957 (46J66) - 15 Ibs. (8 kq) . ..-•w. , ,arn VuucatMl cnlaency Oa58Q On U.S. DOE 'e, prOCed". and aabr*N to FTC Iaoe" requLaum Iscoama comoumo l f Potyuretllane frame type filter Is fumisned unite krt '�^4 or ^cin-meamenzea tumaces. INSTALLATION CLEARANCES - inches (mm) HP.Ft nw onCrrin*t Vent Type I Type "8- - Type "C- Sloes inches ( aim) Inches (o mml Pear 0 inches (0 aim) 0 Incnes 10 mm) '00 tncn (25 mm) I 1 inch (25 mm) Franc I 2 !nches (51 mm) 2 inches (25 mm) Front (service) 24 incnes (610 mm) 241ncnes (610 mmli Floor 1 CJmOusaote VQmousttble Flue 1 incn (25 mm) 5 ,ncn (152 mm) NnC17nIUTal 0n4zMn1j Vent Type Type -9- Type -C— _roes _ incnes (5I mm) _ inches (at aim) Rear 0 ,ntxles (0 mm) 0 tncnes (0 mmI _Top _0 inches (0 mm) -0 inches (0 mm) Front 2 inches (25 mm) 2 inches (25 mm) Front (service) I 24 inches (510 mm) 24 inches (610 mm) F?oor 0 rnctes (0 mm) 0 inches (0 mm) Flue 1 itch (25 mm) 6 inch (152 mm) — —. ," �� at ;0 TO "al m-Aw ,ar nt0uS= 3M W �erimm must ==M 4 ;1e oas o memx-w n iAmenean Nana,al '�.Stan= (ANSI-Z223.11 rrem= Damned of An*ncan NaDOft Stan 2M (ANSI-=11 National Fuel Gas Cocte or NanwiM Standard at Cdnaaa C UCGA.1a9.1. Nawnal Fuel Gas CJOe or Na00n21 StNK=tj of Canadd CANtCGA_149.1. b CAN/CCIA-1492 -nsmaam Cone for Gas Bumng Aooaanoes'. 3 CAUCG1-1492'1nsmllaaon Cane for Gas Bturt,nq Acpgnm3e. a ne me NOTE 1n me ue slang must mrtiorrrf moos otl�+ed n `1OTE4n Me U.S. to SON muss CON= !a ra mecfoag otrmnea rf clrrent U.S..S. uiA.G.i aamm GAMAIAi A vellmfg tables. Affwn rl Naaorral SM,,,ra enarfq abler. AfriW2n Naucrtel Standard (ANSI-Z2231) Naoorwl Fie! Gas Good or aopucaae art A93m of aml (ANSI•Z223.1) NaOor-M reel Gas Coos or aoouraae nmymons of icx= 5tulmng 000e: in Caro= tm song airs[ caraoan n are mWj0as bwiding Tees In Canada due stanq rnl5[ grxorm to 21e rrem oumnea in Naooft SMnaala of Canada CANCGA-149.1 ano 2 ouMned in Naaonal Sandra Of Canada CANC:aA-149.1 ano 1 Lm c== moon Pwrm a OwNeen farxat aoo or sdm ano budding psm B R DATA 80UHG2 80UHG2-60 AND 80UHG2-75 BLOWER PERFORMANCE External Pressure Static High Air Volume at Various Blower Speeds Medium -High Medium -Low Low in. w.g. Pa cfm Us ctm Us cfm Us efm Us 0 0 127 12 60 980 160 77 365 070 270 .05 1245 590 975 460 770 365 565 265 10 25 1220 575 975 160 770 365 565 255 15 37 1195 565 1 965 455 765 360 560 255 .20 50 1170 550 9W 155 760 360 560 { 265 25 a2 11a0 540 950 450 760 360 555 1 260 30 75 1110 525 940 1 "5 760 360 550 250 40 100 1 500 910 130 750 355 545 255 .50 125 990 465 1 880 a15 740 350 540 1 255 00 1 t50 I 125 810 380 390 325 630 250 i0 175 800 1 380 740 350 530 �a5 320 2a5 - td � measuntd external to un wr t rt ln In. (25 mm) ceaname utter 80UHG3-60 NO 80UHG3-75 BLOWER PERFORMANCE Extemat Static Pressure Air Volume at Various Blower Speeds High 9 I Medium -High Medium -Low Low in. w.g. 0 05 10 t5 20 .25 30 10 .50 50 70 l - - AH au Data is I Pa I 12 1 25 37 1 50 62 1 75 100 1 125 1 150 175 measures extemal to cfm 1425 1415 1400 1385 1370 1350 1 0 1 0 1210 3070 unit waif 1 m 25 Us 370 370 660 555 545 635 630 505 370 535 505 inn csTt, 12a0 1230 1220 I 1200 1180 1160 1td0 1095 1040 985 920 I Us 385 580 575 565 355 545 540 515 ago 165 -A35 cfm 1000 995 990 985 980 970 955 925 900 860 800 us 470 470 -165 165 160 160 450 135 425 105 380 crm 800 800 1 795 795 790 780 i70 750 1-20 680 Us 380 380 375 1 375 375 370 365 355 340 320 530 1 300 ( 1 ceanade *w (not tirtesneaf ,n Sara. Also see r�[er Av r 80UHG4- OUHG3/a-100 AND 80UHG3/4-120 BLOWER PERFORMANCE Extemal Static Pressure Air Volume at Various Blower Speeds High Medium -High Medium Medium -Low Low in. w.g- Pa ctrtt Us ctrn IUs cim Us ctm Us ch"--T Us 0 05 .10 15 .20 25 .30 50 .60 70 NOl c - au au data is 0 12 25 37 30 62 75 100 125 t50 175 measured external 1830 1815 1 1800 1 1875 1 1750 1 225 1700 1600 1 880 to ,um w,m 1 86-3 855 850 885 825 315 800 780 755 730 700 m ; 25 rn.-n, r-�.,� 1600 1585 1570 1550 1530 1515 1500 1460 1420 1380 1330 f to , 755 750 740 730 720 715 710 690 370 650 530 - .. _ 1325 1320 1315 1310 1300 1290 1275 1245 1210 1170 1130 -_ 625 625 (320 620 615 510 600 590 570 550 535 1070 1070 1070 1065 1060 1050 1.40 040 1020 1000 980 960 505 505 505 505 500 195 880 880 880 875 875 al 415 1 415 415 at5 870 110 ago 180 470 ' a60 870 at0 860 840 820 405 395 385 45J 90 37 c 80UHG ! Page 4 ► BLOWER DATA 0UHG4/5-100 NO 80UHG415-120 BLOWER PERFORMANCE Extern al Static Pressure A ir Volume at Various Blower Speeds High Medium -High Medium Medium -Low LOW in. w.g. Pa cfm Lis ant Us ctm Us cfm L/s din Us 0 0 2450 1155 2160 1 1020 1 1970 930 1 1700 800 1500 710 .10 12 2440 1145 2150 1015 1960 925 1995 800 15M 710 t0 25 2430 t1a5 2150 1015 1960 925 1690 800 1495 705 .15 37 2415 1140 2135 1010 1950 920 1685 795 1495 705 .20 50 2400 1135 2120 1000 1940 415 1680 795 1490 705 •25 62 2380 1 1125 1 2105 995 1930 910 1675 790 1480 700 30 75 2360 1115 2090 1 985 1915 905 1670 790 1470 1 695 .40 100 0 1090 2050 965 1870 880 1550 780 1440 1 680 50 125 2260 1065 2000 945 1810 855 1610 760 1410 665 .60 150 t030 1950 1 920 1750 925 1560 735 1370 645 70 NOTE - Z air aata IS 175 me8SUr9a 848ma1 2100 0 unit wart t vL 990 [25 mmi r�oanr.s 1890 tim. �..... 890 1 ,. 1700 .....� , �� _-- 800 ^`-- - - ,. 1520 715 1330 630 FILTFR AIR RFCICTAmrc din (Us) in. w.g. (Pa) 0(0) 0( ) 200 (95) 0.01 (2) 400 (185) 0.03(7) 600 (280) 0.04 (10) 800 (375) 0.06 (15) 1000 (470) 0.09(22) 1200 (560) 0.12 (30) 1400 (655) 0.15 (37) 1600 (750) 0.19(47) 1800 (8451 0.23 (57) 2000 (935) 0.27 (67) 2200(1030) 0.33(82) 2400(1125) 0.38(95) �600 (12201 0.44(1101 HIGH ALTITUDE DEBATE Unit does not require gas pressure adjustment wnen operating at elevations of 0 to -,sw feet (0 to 2285 m). See taole for correct manrfold pressures for natural and LPG/Prooane gases. In Canada, certification for installation at allitudes over 45W feet (1372 m) acove sea levei is the jurisdiction of local authorities MANIFOLD GAS PRFSGt in;: ALTITUDE ft. (m) Fuel Manifold Pressure (Outlet) in. w.g, (kPa) 0-7500 (0 - 2285) Natural Gas 3.5 (0.87) 0-7500 (0 - 2285) LPG/Prooane 9.0 - 9.5 (2.24 - 2.37) HORIZONTAL VF:NT11ur DCn�uocewruT� .�•L-_ �._ .. Furnace Model No. Veto Pipe Diameter Furnace Connection Vent Pipe Minimum Equivalent Length Vent pipe Maximum Equivalent Length Horizontal Venting Transition Required in. I mm feet meters feet meters I in. min 830 HUHG3 0 3 76 10 3.0 60 18.0 =3 to 4 rM76 to 102 30UHG2-75 80UHG3.75 8OUHG4.75 80UHG3(4-100 80UHG4/5-100 4 102 10 3.0 60 18.0 - - - - - - - - 80UHG3/4-120 80UHG4/5-120 VENTING NOTES - Elbows - One 3 incn (76 mint atamwiar d5° Une 4 intch (102 min) Ut diameter 451 elbow is eavalem to a feet (1.2 m1 at straignt vent pine. One 3 inch (76 min) 90- elbows equtvalem to 5 teet t 1 S ml of straight vent Oros. One 4 irtt7t (102 Min) 904 elbow is eotmalent to 7 feet (2.1 m) of straight vent woe. Two 4.5' elbows are em al to one 904 tbow. Tees One 3 iricti (75 mm) atameter tee is equttralent to 19 teat (5.8 m).ot siratgftt vent ptoe. One 4 inch (102 min) diameter tee is eaumalent to 25 teet (7.5 m).ot straignt vent oioe. Trarmbon - 3 ineti to 4 indti (76 mm to 102 min) w3nwtlon is eautvalem to 2 filet (0.61 m) at siraigm vent pine. NOTE E gjnjm hentm � flower venter should be m=1100 on too of flue aaamor at tneucea dmtt blower. emmig appiy=tions require oononai Sidewau Power vermng KiL ..DIMENSIONS - inches (MM) GAS PIPING 2 (51) ELECTRICAL INLETS _ INLET I (Top & Bottom) E 0 -- ( - 4D 0 --- II (499) i FLUE 4.1/4 (483) OUTLET SUPPLY AIR OPENING 'NOTE- Supply air opening at rear and sides of cabinet is - 1 equipped with a 3/4 inch (19 mm) scared flange that may (25) be bent out 90° for plenum connection. Dimensions shown are afiLr flange is bent out. Double scored flange at front of supply TOP VIEW g pply air opening may be bent out for a total opening dimension (front to rear) of either 19-1/2 inches (495 mm) or 19 inches (483 mm). q 41111129-5/8 2 (51) (�) AI R tFLOW o F Left Side G Right Side GAS PIPING /INLET (Both ) If 00 ELECTRICAL INLETS (Either Side) r-1 — — — — — — — r-T L-1 L1 19-1/2 (495) —� 15 RETURN AIR (381) KNOCKOUT (Ether Side) r� r� 1 (25) 1 (25) "NOTE- Return air opening is equipped 314 (19) Retum Air with a 3/4 inch (19 mm) flange 1 --C p g 1 that may be bent out 90° for "19-1/2 Return Air 1 (25) 0 enin (25) plenum connection. Dimensions (495) Opening (25) FRONT VIEW shown are atff flange is bent 01L SIDE VIEW r� Model No. A 8 C 0 E F G SOUHG2-45 80UHG2-60 in. 17 36-1/4 15 6-314 2-7/16 6-1/2 12 80UHG2-75 80UHG3-60 80UHG3-75 mm 432 921 381 171 62 114 254 80UHG4-75 80UHG3/4-100 80UHG3/4-120 in. 20-1/2 39 18-1/2 8-318 4-1/4 8 13-1/2 80UHG4/5-100 80UHG4/5-120 mm 521 991 470 213 108 203 343 r Technical P1011Hr; / Panw R t•� VALUE "" 12 CONDENSING UNITS EXPANSION VALVE SYSTEMS Up to 13.50 SEER *23,200 to 58,000 Btuh (6.8 to 17.0 kW) Cooling Capacity 9� CIPLISTED 2 thru 5 Tons (7.0 to 17.6 M) 'nR1 and DOE Cattriliod Ratings ,so sm AmsrE m WORD CLASS CUAItiY Applications • SEER'S of up to 13.50. • 2 through 5 Ton (7.0 through 17.6 kW) sizes. • Single phase power supply. • Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. • Matching blower powered or add -on furnace evaporator units provide a wide range of cooling capacities and applications. See ARI Ratings table. • For evaporator unit data, see Coils — Blower Coil Units, this section. • Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory insuring proper operation. • Installer must set condensing unit, connect refrigerant lines and make electrical connections to complete job. Approvals • Rated in accordance with ARI Standard 210/240-94. • Sound rated in Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270-95. • Tested in the Lennox Research Laboratory environmental test room. • Rated according to U.S. Department of Energy (DOE) test procedures. • Condensing units and components within bonded for grounding to meet safety standards for servicing required by U.L. N.E.C. and C.E.C. • Units are U.L. listed and C.S.A. certified. • Developed in accordance with ISO 9000 quality standards Equipment Warranty • Compressor — Five years. • All other covered components — One year. • Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. 12ACB Bulletin No. 210077 April 1996 Supersedes Aonl 1995 Unit Cabinet • Heavy gauge steel cabinet with five station metal wash process. • Baked -on outdoor enamel paint finish provides superior rust and corrosion protection. • Painted base section. • Control box is conveniently located with all controls factory wired. • Corner patch plate allows access to compressor components. • Drainage holes are provided in base section for rnaisture removal. Copper Tube/Enhanced Fin Coil • Lennox designed and fabricated coil. • Ripple -edged aluminum fins. is Copper tube construction. • Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. • Fin collars grip tubing for maximum contact area. • Flared shoulder tubing connections/silver soldering construction. • Coil is factory tested under high pressure to insure leakproof construction. • Entire coil is accessible for cleaning. • PVC coated steel wire toll guard furnished as standard. Condenser Fan • Direct drive fan moves large airvolumes uniformly through entire condenser coil for high refrigerant cooling capacity. • Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. • Fan motor has sleeve bearings and is inherently protected. • Motor totally enclosed for maximum protection from weather, dust and corrosion. • Rain shield on motor provides additional protection from moisture. • Louvered steel top fan guard furnished as standard. • Fan service access accomplished by removal of top panel. 0 The maple leaf svmtoi in this bulletin denotes Canadian only usage where aoolicable 7996 Lennox Industries Inc. NOTE — Due to Lennox' ongoing commttment to quality. Soectfications. Ratings and Dimensions suniect to cnanno ARI RATINGS Unit Size & Model No. 'Sound Rating9 Number (db) *ARI Standard 2101240 Ratings Up -Flow VD-wn-Flow Horizontal Ex ansion Valve Kit Required Cooling p• SEER EER Total Unit Wags Bich kW Evaporator Coils 2 Ton 12ACS24 (76) 23,600 6.9 12.25 11.15 2120 C26-21(FC) - - - - - •Factory Installed 24,000 7.0 12.50 11.30 2130 C23-26(W)(FC) _ _ _ - - _ - _ LB-85663J (26K34) 24,200 7.1 12.50 t 1.40 2125 C23-31(W)(FC) . - - - _ _ _ _ 24,400 7.1 12.75 11.50 2125 C26.26(W)(FC) - - - - - _ - - *Factory Installed 25.400 7.4 13.25 11.90 2130 C26-31(W)(FC) - - - - 23.200 6.8 12.00 10.95 2120 - - - - CR26-21 25.000 7.3 13.00 11.75 2130 - - - - CR26-31 - _ . - LB-85663J (26K34) 23,800 7.0 12.25 11.25 2120 - - - - .... CH23-31 Btuh kW SEER EER Watts Blower Coil Units Valve 24,000 7.0 12.05 11.40 2105 C829M-21/26 (Multi -Position) *Factory Installed 24,200 7.1 12.05 11.40 2125 C829M-31 (Multi -Position) 24,400 7.1 13.05 11.50 2120 CB30M-21/26 (Multi -Position) 25,600 7.5 13.50 12.35 2075 C83OM-31 (Multi -Position) 24,000 7.0 12.50 11.30 2120 O CVP10-26/EC10Q3 .... - - _ - 25 Ton 12ACB30 U.S. (78) Canada (76) yrRated in a[rlfrdane* Stuh kW SEER EER Watts Evaporator Coils Valve 29,400 8.6 12.25 11.00 2675 C23-31(W)(FC) .. - - LB-85663J (261<34) 29,400 8.6 12.50 11.10 2650 C23-41(W)(FC) - - - - ---- 29,600 8.7 12.50 11.15 2655 C26-26(W)(FC) .... _ . _ _ eFactory Installed 31,000 9.1 13.00 11.70 2655 C26-31(W)(FC) .... I - - - 31,200 9.1 13.00 11.30 2660 C26-41(FC) .... 30,400 8.9 12.75 11.45 2655 CR26-31 LB-85663J(26K34) 31,200 9.1 13.00 11.75 2660 ---- CR26-41(N)(W) ---- 29.200 8.6 12.25 11.05 2645 - - - - .... CH23-31 30,400 8.9 12.75 11.45 2655 - - - - - - - - CH23-41 Btuh kW SEER EER Watts Blower Coil Units Valve 27,800 8.1 12.05 10.60 2625 C329M-21/26 (Multi -Position) *Factory Installed 29,400 8.6 12.50 11.05 2655 C329M-31 (Multi -Position) 29,600 8.7 12.60 11.10 2660 I C829M-41 (Multi -Position) 29,600 8.7 12.60 11.30 2625 C330M-21126 (Multi -Position) 31.200 9.1 13.20 12.20 2560 C830M-31 (Multi -Position) 31.200 9.1 13.05 12.0 2600 C33OM-41 (Multi -Position) 31,400 9.2 13.50 12.70 2470 C831MV 41 (Multi -Position) 29,800 8.7 12.70 11.25 2650 O CVP10-31/EC10Q3 - - - . _ _ _ 30,400 warn AGI 8.9 1 cr�..n�a 12.75 �innen. 11.45 ar.e ,ee 2655 �,+. _ O CVP10-41/EC1003 - - - - - - - - --- --- - - -- -• -- • •-- -1 o. ac.nyeaawre, ou r (cr �r oo i or-r i iy-mil wo entering evaporator air with Z5 tt. (7.6 ml of connecting refrigerant lines. 'Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. " Kit is required and must be ordered extra, unless shown as factory installed *Furnished as standard with coil. NOTE - Shaded area denotes most popular evaporator coil. 12ACB / Page 4 ARI RATINGS Unit Size & Model No. "Sound Rating Number (db) *ARI Standard 210/240 Ratings Up -Flow own -Flow Horizorttal '•Ex ansion Valve Kit Required Cooling g p SEER EER Total Unit Watts 8tuh kw Evaporator Coils 3 Ton U.S. i78) U.S. (7) Canada (76) 34,600 10.1 12.00 10.55 3265 C23.41(W)(FC) • - - - • • . _ LB-85663J (26K341 35.400 10.4 12.50 10.75 3290 C26.31(W)(FC) .. • . *Factory Installed 35,600 10.4 12.25 10.80 3290 C23-46(FC) - - - - .... LB-85663J (26K341 36,200 10.6 12.50 10.95 3300 C26-41(FC) .... _ . - _ *Factory Installed 36,600 10.7 12.50 11.05 3305 C26.46(FC) • - - - . _ _ _ 36,800 10.8 12.50 11.10 3310 C23-51(FC) - - - - .... LB.85663J126K341 34,400 10.1 12.25 10.75 3200 ... - CR26.31 ---- 36,200 10.6 12.50 10.95 3305 •... CR26-41(N)(W) -- -900 35,600 10.4 12.25 10.80 3295 - - - - .... CH23-41 . . Sit kW SEER EER Watts Blower Coil Units Valve 33,600 9.8 12.05 10.45 3225 C829M-31 (Multi -Position► *Factory Installed 34,200 10.0 12.05 10.30 3315 C829M-41 (Multi -Position) 35.400 10.4 12.50 10.65 3320 C829M-46 (Multi -Position) 35,600 10.4 12.75 10.75 3310 C330M-31 (Multi -Position► 36,000 110.51 13.05 11.10 3250 C83OM-41 (Multi -Position) 36,200 10.6 13.05 11.30 3210 C830M-46 (Multi -Position) 36,200 10.6 13.50 11.45 3165 C831MV 41 (Multi -Position) 37000 10.8 13.05 11.50 3225 C83OM-51 (Multi -Position) 37,200 10.9 13.50 12.00 3100 C831MV 51 (Multi -Position) 35,400 10.4 1 12.25 10.75 3290 O CVP10-4&EC10Q4 35,600 10-41 12.25 10.80 3290 O CVP10.41/EC1003 - • - - 33.5Ton41,500 Stuh kW SEER EER Wags Evaporator Coils Valve 37,800 11.1 11.50 9.90 3815 C23-41(W)(FC) -- 1 8-85663K (26K35) 40,000 11.71 12.00 10.20 3930 C23-46(FC) ---- 40,000 11.71 12.25 10.45 3830 C26.41(FC) .... - *Factory Installed 41,500 12.21 12.25 10.50 3945 C26-461FC) - - - - 42.000 12.31 12.30 10.85 3945 C23-51(FC) LB-85663K (26K35) 42.000 112-31 12.50 10.65 3950 C26.51(FC) - - - - .... *Factory Installeo 41,000 12.01 12.25 10.40 3940 _... CR26-41(N)(W) -- LB-85663K (26K35) 41,500 12.21 12.50 10.50 13950 - - - . CR26 51(1\1)(W) do 12.2 12.25 10.50 3950 CH23-51 Stuh kW SEER EER Watts Blower Coil Units man Valve 37,800 11.1 11.50 9.55 3950 C829M-41 (Multi -Position► •Factory Installed 40,000 11.7 12.05 10.00 3995 C829M-46 (Multi -Position) 40,500 11-91 12.50 10.60 3825 C830M-41 (Multi -Position) 40.500 11-91 12.60 10.65 3810 C331MV 41 (Multi -Position) 42,000 12.31 12.05 10.40 4045 C829M-51 (Multi -Position) 42.000 12.31 12.50 10.90 3850 C830M-46 (Multi -Position) 42000 12.3 12.75 10.95 13840 CB30M-51 (Multi -Position) 42,500 12.5 13.05 11.35 13740 CB31MV 51 (Multi -Position) F40,500 11.9 12.00 0.30 1935 3 O CVP10.46/EC10Q4 500 11.9 12.00 10.30 13940 1 O CVP10-51/EC10Q4 - ----- -- •�.� i4a �i uutuuur air [emperature, 2Su-r IL/-Gl op / bi'F I19'G wo entering evaporator au with 25 it. (7.6 m) of connecting refrigerant lines. 'Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. " Kit is required and must be ordered extra. unless shown as factory installed. •Fumished as standard with coti. NOTE - Shaded area denotes most popular evaporator coil. 12AC8; Page 5 ► Unit Size & Model No. g 'Sound r (d Number (db) *ARI Standard 210/240 Ratings Up -Flow Down -Flow Horizotttal ••Ex ansion Valve Kit Required Cooling Ca g p- SEER EER Uo rtl Watts Stuh kW Evaporator Coils 4 Ton 44,500 12.3 12.25 10.50 4240 C26-41(FC) _ . _ •Factory Installed 46,500 13.6 12.50 10.75 4340 C26-46(FC) . _ _ _ 47,500 13.9 12.50 10.80 4400 C23-51(FC) - - - - LB-85663K (26K35) 48,000 14.1 12.50 10.80 4440 C26.65(FC) .... *Factory Installed 48,500 14.2 12.50 10.85 4440 C26-51(FC) 49,000 14.4 12.75 11.00 4460 C23-51/65(FC) - - - - - - - - LB-85663K (26K35) 50,000 14.7 13.00 11.15 4460 C26.65(FC)EAP - - - .... *Factory Installed 46.000 13.5 j 12.25 10.55 4340 CR26-41(N)(W) LB-85663K (26K35) 48,000 1 a.1 12.50 10.85 4440 - - - - CR26.51(N)(W) - . - _ 47,500 13.91 12.50 10.75 4440 _ _ . - - - - CH23-51 12ACB48 U.S. (8 Canada (801 50,000 14.71 13.00 11.15 4460 - - CH23 68 Btuh kW SEER EER Watts Blower Coil Units Valve 45,000 13.2 12.50 10.70 4215 C830M-41 (Multi -Position) *Factory Installed 45,000 13.2 12.50 10.70 4200 C831MV-41 (Multi -Position) 46,000 13.5 12.05 10.20 4505 C829M-46 (Multi -Position) 46,500 13.6 12.75 10.95 4245 C830M-46 (Multi -Position) 47,000 13.8 12.25 10.50 4475 CB29M-51 (Multi -Position) 47,500 13.9 12.35 10.55 4510 C829M-65 (Multi -Position) 48,500 14.2 13.10 11.25 4315 C830M-51 (Multi -Position) 48,500 14.2 13.05 11.10 4365 CB30M-65 (Multi -Position) 48.500 14.2 13.25 11.35 4265 CB31MV-51 (Multi -Position) 49,000 14.4 13.20 11.45 4285 C831MV-65 (Multi -Position) 46,500 13.6 12.25 10.55 4420 O CVP10-51/EC10Q4 - . - . - _ - - a8,000 14.1 12.50 10.75 4440 o CVP10-65/EC10Q5 _ _ - . gTon *Rated in accordance Stun kW SEER EER Watts Evaporator Coils Valve 54,500 16.0 12.00 10.15 5380 C26-65(FC) •Factory installed 55,500 16.3 12.00 10.15 5440 C2651(FC) 57,000 16.7 12.00 10.30 5540 C23-51/65(FC) ... - - - - LB-85663K (26K35) 58,000 17.0 12.25 10.50 5500 C26-65(FC)EAP - - - - *Factory Installed 55,500 16.3 12.00 10.20 5420 - - - - CR26-51(N)(W) - - - - 57,000 LB-85663K (26K35) 16.7 12.00 10.20 5560 CH23 65 Btuh kW SEER EER Watts Blower Coil Units Valve 55,000 16.1 11.40 9.65 5700 C829M-51 (Multi -Position) •Factory Installed 55,000 16.1 11.50 9.75 5640 C829M-65 (Multi -Position) 55,500 16.3 12.50 10.60 5240 CB30M-51 (Multi -Position) 55,500 16.3 12.65 10.70 5190 C831MV-51 (Multi -Position) 57,000 16.7 12.50 10.55 5395 C830M-65 (Multi -Position) 57,000 16.7 12.60 10.65 5360 CB31MV-65 (Multi -Position) 56,000 with ARI 16.4 gtanei-A71nr)An.CC2C 12.00 1 10.25 5500 - - O CVP10-65/EC10Q5 connecting refrigerant lines. - - -- -- -• --• ---• �•• .o.• N........ ov r i41 w uu i cr-r- I in-w wo entering evaporator art with 25 ft. (7.6 m) of 'Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. '• Kit is required and must be ordered extra, unless shown as factory installed. •Fumished as standard with coil. NOTE -Shaded area denotes most popular evaporator coil. 12AC13 / Page 6 ► TXVRATINGS tf � IOTE - For Temperatures and Capacities not shown in tables, see b - Unit R tin Table Correction Factor Data In Miscellaneous Engineering Data section. 'I7A!`R7A _-- ruse e, Outdoor v - _- - Bring Condenser Coil Enter- ing Total 85°F (29'C) 95-F (35°C) 105'F(41°C) 115°F 146°C) Wet Bub Air Volume C000lin Com- Sensible To Total C °�I Com- Sensible To Total Total Com- Sensible To Total TO�I Com- Sensible ��� pressor Ratio ISM g - CapacityMotor pressor Ratio ISM Cooling Capacity pressor Ratio ISM Cooling ��� pressor To Total Ratio ISM L/s I Watts Input Dry Bulb .F Dry Bulb pry Bulb Dry D Bulb ature Watts - Motor Motor cfm 11 kW Btuh 4°C127°C kW Btuh n 24°L'IZ7° 29'C I kW Btuh Input 4 C'27'C�°C kW Btuh Inputt 4C 27°C129°C 63°F 305 650 116.7 1 22,700 1470 .72 .86 .98 1 6.4 1 21,900 1660 1.731.87 .99I1 6.2I 21,100 1880 .741.8911.00 5.9 20,200 2110 1.00 (17.2cC) 3751 800 116.91 23,600 1470 .76 .92 1.001 6.7 1 22,700 1670 1.78 1.94 1.0011 6.4 21,800 1880 .791.95 11.00 6.1 120,900 2120 .75 .81 .91 .97 1.00 450 950 117.11 24,300 1470 .81 .97 1.001 6.9 1 23,400 1670 1.83 1.99 1.0011 6.61 22.500 1880 .85 1-0011.00 6.4 21,700 2120 1.00 1.00 67'F 3051 650 7.t 1 2a,300 1a70 .56 .69 .82 6.8 23,300 1670 .57 .70 .8a 6.6 1 22,400 1880 .57 .72 .85 .87 3751 800 117.3 1 25,000 1480 .59 .74 .89 7.0 24,000 1670 .60 .75 .91 6.7 23.000 1890 .61 1.771 .92 6.4 22.000 19.4cC) 2120 1.62 1.79 4501 950 17.5125,600 1480 .621.79 .94 7.2 24,500 1680 .63 .81 .96 6.9 23,500 1890 .641.83 .98 .94 71 °F 305 650 7.6 267000 1480 .42 1.54 .6611 7.3 1 24,900 1680 .42 .55 1.68 11 7.0 23,900 1890 .43 1 .56 .69 116.7 1 22,9W 2130 1.57 (21,7cC) 3751 800 7.8 26,700 1480 .431.57 .72 7.5 25.600 1680 1.43 .58 .73 1 7.2 24.500 1900 .aa .59 .75 6.9 23,500 2130 .43 .ad . 00 I 27� NOTF - 450 950 All vali�ac ar 8.0 27 200 cc r 1 a80 ..,., .4a ...� a .60 .77 7.6 26 100 1680 .45 .62 .78 7.3 25 000 1900 .45 1 .63 .80 7.0 23 900 2130 .a6 .6a '17AP`t?7A f-U�� 5tow It /Z I I c Outdoor Air Temperature r. I IF Entering Condenser Coil Enter- Total 85°F (29°C) 95°F 1351CI 105°F(411C) 115°F (46°C) Wet Bulb Air Volume Total Conlin Com- Sensible To Total Total Com- Sensible To Total Total Com- Sensible To Total Total Com- To Totae emper- CaPaci y Pressor Motor Ratio IS/TI Ca cling p �Y prassor Motor Ratio IS/TI Cooling Capacity pressor Motor Ratio ISM Cooling pressor Ratio IS/T) Capacity Dry Bulb afore Watts 5°F180°F 'F Input Dry Bulb Dry Bulb Motor Dry D Bulb 5. 80° 85-F kW Btuh 5-F 80° 85'F kW Btuh aputtts 5°F 80 85°F L/s cfm kW Btuh Input 4°C{27°C 'C kW Btuh Inap 24" 7 29cC 4=C 27 4°C 27 63'F 305 650 6.9 23,700 1470 .72 .85 .98 6.7 22,700 1670 .73 .87 .99 6.4 21,800 1880 747.89 1.00 6.1 20,900 2120 .75 .91 1.00 (172°C) 375 800 17.21 24,600 1 1480 .77 .92 1-001 6.9 1 23,600 1670 1.781.94 1.00 11 6.61 22.600 f 1890 .80 1 .96 11.00 6.4 21,700 2120 .82 .98 1.00 450 950 17.41 25,400 1480 .82 .98 1.001 7.2 1 24,400 1680 .83 1.99 1.00 1 6.9 1 23,400 1 1890 .8511.001.00 6.6 22,500 2130 .87 1.00 1.00 67°F 305 650 7.4 25,300 1480 .56 .69 .82 7.1 24,2001 1680 .57 .70 .84 6.8 23,200 1890 .57 .71 .85 6.5 22,200 2120 .58 .73 .88 (19.4°C) 375 800 7.6 26,100 1480 .59 .74 .89 7.3 25,000 1680 1.60 .76 .91 7.0 23,900 1890 .61 .771 .93 6.7 22,900 2130 4501 950 7.8 26.700 t480 .621.791.95 7.5 25.600 1680 .631.81 .97 7.2 24,500 1900 .6e .83 .99 6.8 23,300 2130 .62 .79 .95 1.00 71°F 3051 650 7.9 27,100 1480 1 .42 1.54 .66 7.6 26,000 1680 1.a2 .55 .68 7.3124.900 1900 .421.561.69 7.0 23,800 2130 .66 .431.57 .85 (21.7°C) 3751 800 8.2 27,900 1480 .431.57 .72 7.8 26,700 1690 .43 .58 .73 7.5 25,500 1900 .4a .59 .75 7.2 2a,400 2130 .aa .51 .70 .77 NOTF - 450 All. 950 i.„ 8.4 - 28,500 ec .. 1480 ......... .... as .61 .77 8.0 27 200 1690 .a5 .62 .79 11 7.5 1 26,000 1910 .45 1 .63 .81 7.3 24 800 1 2140 .as .65 Al 17A�`R7A _ r•t77enA �, i�c Enter- Bing t Temper- attire Total Volume Outdoor Air Temperature Entering Condenser Coil 85°F (29°C) 95°F (35°CI 105°F(41°C) 115°F 146°C) C000tln g Capacity kW Btuh Com- pressor Motor Watts (opal Sensible To Total Ratio IS/T) Total Cooling Capacity Com- pressor Motor Sensible To Total Ratio ISM Total Cooling Capacity P 't1' kW Btuh Com- pressor Motor Watts Input To Total Ratio (SIT) Total Cooling Capacity kW Btuh Com- Pressor Motor I^P� Sensible To Total Ratio ISM Dry Bulb L/s cfm Dry Bulb 24°Cl27° 29°C D Bulb ry 4'C 27 °C Dry 4°C BFFu{{l88b 20°C(29'C 75-F4°C�27°C �` kW Stuh Watts Input 63°F 305 650 16.91 23,600 1470 .72 .86 .97 11 6.7 1 22,800 1660 .73 .87 .98 1 6.4 1 21,900 1870 .75 .89 .99 1 6.2 1 21,100 2110 .76 1.91 11.00 (172°C) 375 800 17.21 24,400 1470 .77 .92 1.D011 6.9 1 23.600 1660 .78 1.93 1.061 6.71 22,700 1870 .80 .95 1.001 6.4 1 21,800 2110 .81 .97 11.00 450 950 17.41 25,100 1470 .82 .97 1.0011 7.1 1 24,200 1670 .83 1.98 1.00 1 6.9 1 23,400 1880 .85 .99 1.001 6.6 1 22,500 2110 .87 11.0011.00 67°F 305 650 17.41 25,100 1470 .57 .70 .8311 7.1 1 24,200 1670 .57 .71 .84 1 6.8 23,300 1880 .58 .72 .86 1 6.5 1 22,300 2110 .59 1.74 1 .88 (19.4°C) 375 800 17.61 25,900 1470 .59 .75 .8911 7.3 1 24.900 1670 1.60 .76 .91 1 7.0 23,900 1880 .61 .78 .92 6.7 1 22.900 2120 .62 .79 .94 450 950 7.7 26,400 1470 .62 .79 .94 7.4 25,400 1670 .63 .81 .96 7.2 24,400 1890 .64 .83 .97 6.9 23,400 2120 .65 .84 .99 71,F 305 650 7.9 26,900 1470 .43 .55 .67 7.6 25,800 1670 .43 .56 .68 7.3 00 1890 .43 .56 .70 7.0 23,800 2126 .43 .57 (21,7°C) 375 800 8.1 27,600 1470 .43 .58 .72 7.8 26.500 1680 .44 .59 .74 7.5 �25,500 1890 .aa .60 .75 72 24,400 2130 45 61 .71 77 NOTF - 450 All v 950 i roe �. 8.2 28 100 °c t470 ..,.,ems �..,. 45 - .61 _,-. .n . 7.9 27 0001680 a5 .62 .79 7.6 00 1890 .a5 .63 I .81 7.3 2a 800 2130 .a6 .6a .82 17A�`R7A - r�o7nnA e, Enter- Wet Bulb Temper- atureWatts Total Air Volume Volume Outdoor Air Temperature Entering Condenser Coil 85°F (29°C) 951F (351C) 105'F(41°C) 115'F 146°C) Total Cooling CapacityMotor Com- pressor Sensible To Total Ratio IS /TI Dry Bulb Total Cooling Capaerty kW Btuh Com• pressor Motor Wam 1nPnt Sensible To Total Ratio ISM Total Cooling Capacity Com- pressor Motor Watts Input Sensible To Total Ratio ISlT1 Total Cooling �p� Com- Pressor Motor Watts Input Sensible To Total Ratio ISM Dry Bulb Dry D Bulb Us cfm 11 kW Btuh Input 5°F 4°C 80°F 7°C cF 5'F 24" 80° 27 85°F 29'C kW Bich Dry Bulb 5"F 4 C 80' 27' 85'F 'C kW Btuh 5'F 4°C 80 FF1185°F 27°C129°C 63°F 330 700 117.11 24,200 1470 1 .74 .88 .9911 6.8 1 23,300 1660 .75 1.89 1.00 1 6.61 22,400 1880 .761.9111,00 6.3 21,500 2110 .78 .93 1.00 (17.2°C) 375 800 7.2 24,700 1470 .77 .92 1.00 7.0 23,800 1670 .78 1.93 1.00 6.7 22,900 1880 .80 .95 1.00 6.4 22,000 2120 .81 .97 1.00 425 900 7.4 25,200 1470 .80 .95 1.00 7.1 24,300 1670 .81 .97 1.00 6.9 23,400 1880 .83 .98 1.00 6.6 22,500 2126 .85 .99 1.00 67°F 330 700 7.5 25,700 1470 .57 .71 .85 7.3 24,800 1670 .58 .72 .86 7.0 23,800 1880 .59 .74 I .88 6.7 22,8W 2120 .60 .75 .90 (19.4°C) 375 800 7.7 26,200 1470 .59 .74 .89 7.4 25.200 1670 .60 .76 .90 7.1 24,200 1890 .61 .77 .92 6.8 23.200 2120 .62 .79 .94 425 900 7.8 26.600 1470 .61 .78 .92 7.5 25.500 1670 .62 .79 .0 7.2 24,5W 1890 .63 .81 .96 6.9 23.500 2130 .6a .83 .98 71°F 330 700 8.1 27,500 1a70 .43 .56 .69 7.7 26,400 1680 .a3 .57 .70 7.4 25,400 1890 .43 .57 .71 7.1 2a.300 2130 .aa .58 .73 (27.7°C) 375 800 8.2 28.000 1480 .43 .58 .72 7.9 26,900 1680 .44 .59 .73 7.6 25,800 1900 .da .60 .75 7.2 2a,700 2730 .44 .61 .77 NOTF - 425 All val. 900 ioc 8.3 28 400 1 1480 1 44 1.60 ETs 8.0 27,200 1 1680 .45 1 61 .77 t 7.6 1 26,100 1900 1 45 1 .62 1 79 7.3 1 25 000 1 2130 1a5 .63 .81 12ACS / Page 10 ► TXVRATINGS VOTE -For Temperatures and Capacrties not shown in tables, see trulletrn -Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 40 -- IliYrl YYr Outdoor Air Temperature Emenng Condenser Coil 85°F (29°C) 95°F (35'C) 105°F(41°C) i 115°F 146°C) Enter- ing Total Air Wet Bub Volume TotaCoolin 9 Com Pressor TSensibll Total _ Com Sensible Total Sensible Total Cooling- I Sensible Temper'�pa� pressor Ratio Cooling rCeosm--rToTotalCoolingCorn- Motor CapacityP Ratio 1STCapacity To Total Pressor Ratio (S/T1Watts Motor atureCapacity Us cfm kW Btuh Input �(Sm yyaOtiV Bub W otorDry Bulb 5 kW Btuh Input 5' 80°f985° kW Btuh Input 5°F180°FI85°F kW Btuh 4 I I Motor pry Bulb Watts Input 5°FI80°Fi85°F a 4°Cf27°Ct29°C 4'CIZ7°C29°C 63°F 14951 1050 10.31 35,200 1 2300 761.90 11.001 9.9 1 33.900 1 2590 1.17 1.52 11.001 9.61 32.600 1 2930 1 .78 1 .93 11.0011 9.1 1 31,2200 3320 1.80 1 11.00 (172°C) 5651 1200 1110.61 36,000 1 2300 .79 1 .94 11.00 10.2 34,700 1 2600 1.80 .96 11.001 9.8 1 33300 1 2940 1 .82 1.97 11.0011 9.3 1 31,900 1 -95 1 3320 1.83 1.99 ll.00 16351 1350 110.81 36.700 1 2310 . 22 1 go I Too 16.41 35.400 2600 ( .83 .99 11.001110,01 34,0001 2940 1 .85 11.0011.001 9.6 1 32.600 3330 1 11.00I1.p0 �,F 495 1050 111.0 37,4001 2310 1.59 .73 .87 10.6136,100 2610 .60 .74 .88 10.11 34,6001 2950 .601.761.9011 9.71 33.1001 .87 3340 1.61 1.771.92 (19.4°C) 565 1200 11.21 38.100 12320 1.61 1.76 1.91 110.81 36.700 1 2620 1 .62 1.78 1.93 1 10.31 35.2001 2950 1 1 1 1 9.8 1 33.600 635 1350 111.3138.600I 2320 .62 .79 .9a .631.801 95 10.9137,2D01 2620 1.641.81 .96110.5135,7001 2960 I.65 .831.98 F10.01 34,1001 3340 .6a .81 I .97 3350 1.66 71'F 14951 1050 111.71 39.900 2330 1 .44I .57 .70 11.3 38.500 1 2630 I .� .58 .72 10.81 36.900I 29 .act I .59 I .73 10.31 35300I .85 1.00 3360 1 I.8I (21.7°C) 16351 565 1200111.9 40.600 2340 I .4S ,59 1 .74I 11.5 39,100 1 2640 1.45 .60 1.75 111.0) 37,500I 2980 I .45I .61 I .77 1110.51 35900 .a5 .75 3370 I.a6 1.62 1 NOTE - 1350 1112.01 41,100 1 All values are gross caoacities 2340 1 and .45 1 .61 1 .771111.61 39.600 1 2640 1.46 1.67 1 .79 1111.11 38,000 1 2980 1 461 .n .81 1110.61 36.300 an nnr inch- o �.,.,.-,,.. h .79 3370 .47 .65 17 A P`OOC -v°�-Y-J IIIY j1 YYr Outdoor Air Temperature Entering Condenser Coil 85°F (29°C) 95°F (35°C) 105°F147°C1 I 115°F 146°C) Enter- ing Total Air Wet Bulb Volume Total Com- Sensible To Total Total Cooling Se^e Conn o Total _ Sensible To Total Total COT- Sensible Temper- Caling pressor Motor Ratio (SM Capacity Pressor Rat (srn Motor Cooling pressor Capacity P Cooling Ca -Dry Ratio (SM[kW pressor To Total Ratio (SM Dry Bulb ature W I^Put Watts Dry Bulb Input �' �I Water Bulb Ply 5°FI80°g85'F Motor Water Dry Bulb Us I fill kW Btuh S-Fls° kyy Btuh kW Input 5'FI88( A°CIz7°Crzs°CI� 24° Btuh 4°C 27°Ct29°C Btuh Input °F 495 1050110.4 35.500 2310 .751.90 11.00 10.1 34,3001 2600 .76 .91 1.00 9.61 32.8001 2940 .781 .9311.00.2 31,400 4°C 3330 1.79 (172°C) 565 1200 10.61 36.300 1 2310 .79 .9a 11.00 10.3 35.000 2610 .801.96 1.00) 9.8 33.600 2950 1.82 .98 11.00 9.4 32.2001 3340 .95 1.00 1,83 1.99 1.00 635 1350 110,9 37,100 232D 1.821.9811.00110.51 35,700 2510 1.83 .9911.00 10.1 3a,3001 2950 1.8511.0011.00 9.6 32.9001 3340 1.87 11.0011.00 67°F 495 105()1111.1137.800 2320 1.59 1.73 1.86 10.7 36.4001 2620 1.59 1.741.88 1 10.21 34.900 2960 1 60I.75I.90IH 9.8 33.4001 3350 1.61 1.771.92 (19.4°C) 5651 1200 1111.31 38.600 1 2330 .611.76 1.911 10-91 37,100 1 2630 1.61 .781.93 1110.41 35.600I 2970 .02 .791.941 10.0 34,0001 MW 1.0-31.81 1.97 6351 1350 1 11.5 1 39.100 1 2330 1 .63 1 .79 1 .95 111.01 37.700 1 2630 1.64 1 .81 1.97 10.61 36.100 1 2970 ' .65 123 1 .98 10.11 34.4001 3360 1.56 1.35 11.00 71°F 495 5651 1050 11.81 40,400 1 1200 a1,100 2340 1 .act 1 .57 1 .70 111.a1 38.900 I 26a0 I .act .58 .71 10.91 37.300 1 2990 1 .act 1 .59 1 .73 10.5 35.700 MW .45 1.60 1 .7a (21-7*C)l 635 1 1112.01 1350 1112.21 2350 1 .act .59 .7a 11.6 39.6001 2650 1.45 .60 .75 11.11 37,9001 2990 1 .45 1 .61 .77 t0.61 36,2001 3380 1.46 1.62 1 .79 NOTE -All values 41,700 1 are gross capacities 2350 1 and 45 1.61 1 77 .tj do nor inriurlo 11.81 o..an^,,,^,, 40,100 I 2650 1 .46 I .67 1 79 1111.3 ii -m ann 1 3000 1 .46 1 .63 I .80 110.8 ­001 3390 1.47 ! .65 i .32 Enter' ut nor Air Temperature Entering Condenser Coil 85°F (29°C) Sensible 95°F 135°C) 1105°F(47°C) 175°F (46°C) ing Total Air Wet Bulb Volume TO�1 Conlin 9 Com• To Total Total Com Sensible To Total Sensible Total Com- � To Total Total Sensible emper. CaPecitY pressor Ratio ISlTI Cooling Capacity ressor Motor Ratio ISlT) Conlin Capacity pressorl Ratio (SM Com- To Total piing pressor Ratio (SM Motor Watts Input Dry BCapa ulb afore Dry Bulb Watts Motor pry Bulb Wattsj75'F city Motor Dry Bulb Watts Us cfm kW I Btuh 5°FI80°FI85`FI 5°F180'F� 85°F� 4°Ct27°C�9°C kW Btuh Input 24°(�V42M 80°F85°F kW Btuh I Input 124°CI27°C�9°CI 5°F 80°g85'F kW I Btuh I Input �4°CI27°C29°C °F a95 5651 1 1050 1200 1 10.21 34.700 10.a 35,500 1 2300 2300 I .76 I .90 11.00 9.8 1 33.500 2590 .77 .92 1.001 9.4 132.200 1 2930 .79 .9a I t.00 9.0 30,800 3320 1.80 1.96 11.00 (17.2°C) 635 1350 10.61 36,200 1 2310 .79 .95 1.98 1.00 10.0 11.00 3a,200I 2600 ,.81 .9611.00 9.6 32.9001 2940 .82 .9811.001 9.2 3T5001 3320 .84 (1.0011.00 495 1050 10.8 .83 1110.21 34,900 2600 j .8a 1.00 ll.00 1 9.8 1 33.600 1 2940 1 .86 11.0011.0011 9.5 1 32-1001 3340 1.88 11.00I 1.00 67°F 36.800 2310 .59 .73 .87 10.d 35.500 2610 .60 .751.89 10.01 34.1001 2950 1 (19,41C) 16351 565 1200 1350 11.01 37500 1 11121 38,100 12320 2320 .61 I .77 I .92 1110.61 10.7 36,1001 2620 1.62 1.78 1.93 1110.21 .61 .761 .91 34,7001 2960 I .631 .80 1 .9 19.7 1 33.100 1 3340 .64 j .82 1 .97 .63 .80 .96 36.600 2620 .64 .82 1 .97 10.31 35.200 1 2960 1 .65 1 I 71°F (21.7-C)l a95 5651 1050 1200 1111.71 11.51 39.300 39.900 2330 2340 1 act 1.60 .57 I .71 tt.t 137.900 111.3 2630 .act .56 (.72 110.61 .8a .99 36.300 1 2970 1 .4a 1 .59 I .74 10.21 34SO01 3360 .45 1.50 1 .75 16351 All values 1350 1111.91 are 40,500 1 gross Capacities 2340 and .45 a5 do .62 1 nor .75 78 1111.41 inriun< 38.500 I 39.000 1 26a0 I.aS 2640 1.46 111. . 1 ... - .61 I.76 63 1 .80 1111.Il - ------- 10.81 36.900 1 2980 1.45 I .62 I .78 37 4L00 1 2980 1 46 1 .64 1 .81 11 10.31 353001 3370 1.46 1.63 1 .79 10.51 35 700 1 3-0 1,47 1,65 1 .83 NOTE - 01 12ACB36 - CH23-b; 7 L IVJ Outdoor Air Temperature Entering Condenser Coil 85°F 129°C) 95°F (35°C) 105°F141°Cl II 115'F la6°G Enter- ing Total Air �� Volume Cooling Com- le Sort otai To Total Total Com- I ToTotall Sensible Total Com. I Total Sensible Tamper- 9 �, Pressor Ratio IS/T) Dry Bulb Conlin g Capacity pressor! Motor Ratio ISM Cooling To Total Capacity pressor Ratio (S/Tl Cooling Corn. pressorl To Total Ratio Motor pry, Bub ISM Dry Bulb attire yy Dry Bulb Capacity Motor Watts 5 80°g85°F kW Btuh Watts Input °F180°FI85°FII Us elm fkW Btuh Input A°C1Z7°Ct29°C 180 kW Btuh Input Watts °FI80°Fj85°F 4 4°CIZ7°C>29'C kW Btith Input 4°C 27°Ct29°C °F a95 565 1050 1 1200 10.41 10.6 35,d00 36.200 2300 2310 .76 I .90 11.00 (10.01 34.100 1 2600 .77 .92 11.00 9.6 32,800 I 2940 I .78 .9a 11.001) 9.2 13L300 3320 .80 .96 11.00 (17 2°C) 6,% 1350 10-- 37.0001 2310 I .79 .95 1.00 10.2 1.001110.d 34,900 2600 I .81 I .96 1.00 9.8 33,500 ! 2940 1 .82 .98 1.001 9.4 32,1001 3330 .84 ll.0011.00 495 1050 11.0 37,600 2320 .821.98 35.600 2610 .8411.0011.00 10.11 34,3001 2950 .8611.00It00) 9.6 32900 33a0 .8811.0011.00 �,F (19.4°C) 5651 1200 11.2 38.300 2320 .59 .7 1 .87 10.6 36200 2620 .601.74 .89 10.21 34,7001 29W 1 .61 .76I .90 9.7 33200 3350 .61 I.78 .92 .61 .j .91 10.8 36.9001 2620 1.62 1.78 .93 10.a1 35.400I 2960 .63 .801 .951 9.9 133800 3350 .6d .82 I .92 635 1350 11.4 38.900 2330 1 .63 . .951 11.0 37,400 2630 1.64 1.82 .97 10.5 35900 1 2970 1 .65 1 .84,1 .99 110.11 34,300 3360 .66 1.86 1.00 71°F 495 1050 11.8 40,100 2340 act .1 .71 1 11.31 38.700 1 2U0 .act .58 .72 10.9 37.1001 2980 .4A I .59 1 .73 10.a1 35saD l 3370 1.45 1.60 1.75 (21.7°C) 565 1200 12.0 40.SOo 2350 .45 .59 .7411.5 39,300I 26d0 .a5 .60 .76 t1.0 37.7001 2490 .a51 .6t 1 .771 10.61 36.0001 3380 1.46 1.63 1.79 NOTE •-Ail 635 values 13 are 12.1 gross 41 400 capacities 2350 and .451.62 do not .78 11.7 inciune evannrmnr 39 800 2650 a6 r1J h.-...,..,.. .63 I .79 �___ 11.2 ____�.__ 39 200 ! 2990 a6 ! .5a I 1 110.7) 36,4001338o 47 1.55 I .83 12ACB / Page 18 ► I COTE - For Temperatures and Capacities not snown in tables, see bull Cooling e in - g Unit Rolm- 7�a1� Correction Factor Data in Miscellaneous Engineering Data section. ��onr•own Outdoor Air I em v• •ure� rttenng Condenser Coil Enner- ing Total Air I 85°F (29°C) 95'F (35'Cl ° 105°F141 C) 115°F (46°C) Bulb Wet Bulb Volume Sensible dotal CornTo Total Total Cooling cam j Toensib4 Total Cow Sensible To Total Total Sensible Corn - Corn- To Total Capaci y pressor Ratio IS/Tl Motor Dry Bulb Capacity Pressor I Ratio ISlll Motor Cooling Pressor Ratio ISM C V Motor p Dry Cooling Capacity Pressor Ratio ISM ature kW Btuh Dry Bulb yy� FBI Input Motor Dry Bulb Watts - - Lis cfrtt II kW I Btuh Watts Input kW Btuh warts 1nPo Bulb ��i 24°C127°d29°CI! 4°C�27°C79°C kW Btuh ^ 4°C'27°Ck29°C 63°F 590 1250 1112.31 41,800 2750 13 1 -89 11.00 11.81 40,300 1 3100 1 .76 I .91 11.00 11.3 38.700 3490 .78 1.93 11.00 110.81 37,000 3930 I 11.00 (17.2°C) 660 14001112.51 42.6001 2750 .78 1.93 11.00 12.01 .11,1001 3100 1.79 1.9411.00 11.51 39.4001 3500 .81 .9611.00111.1 37.8001 3940 .79 1-82 .95 17301 15501112.71 43.3001 2760 1 .811.96 11.00112.3 41.8001 3110 1.821.9711.00111-8140,200 3500 I.84 .9911.00111.3138.500 1 3950 I86 .9611.00 1.00 1.00 67°F 5901 12501113.01 4A.300 1 2770 1.581.72 1.861 12.51 42,600 1 3120 1.59 1.7&-F-a8jj12.0j 40,900 3520 .60 1.751 .90 1111.51 39.100 3960 77 (19.4°C) 660 1 1400 1113.21 45,000 1 2770 1 .501 .75 1 901 12.71 43.300 1 3130 1.61 1.77 1.91 1112-21 41.5001 3520 1 1.781 .61 . .92 11 7301 1550 1113.31 45500 1 2780 1 .62 1.78 1 .93 1112.81 43.300 1 3130 1.63 !.so I .95 1112.31 a2000 .62 1 3520 1.641 .9 .82 1 .9( 111.81 40.1001 3970 1.65 1 71°F 1 590 1 1250 1113.81 47,200 1 2790 1 .43 1 .57 .70 13.31 45.500 1 3140 1 .43 1 .57 1 .71 (12.8) 43.600 3540 1.44 1.58 I .84 121.7°C1 660 1 1400 114.01 47.800 1 2800 .44 1.58 1 .73 13.51 46,0001 3150 1.44 1.59 1.74 12.91 44,100 j 3550 1 .44 1 .7 .60 1.76 2. 22200 1 399 1 7887301 t550 t11e,2 a8.300 120 as .60 I .76I t3JI a6 600 I 3150 s5 I 51 78 0 9 ..45 ..62 NOTE - All values are cross caoacitnes and nn nnr inrinn a---- 1 1, .senVs co�'lIso = 3to0y Outdoor Air Temperature -Entering Condenser Coi! Enter- Total 85'F l29°CI 95°F (35°C1 1051F(41°C) 115°F (46°C) Wet Bulb Vo u�me Total Coolin Corn- Sensible To Total Total Sensible Com• To Tota{ l Total Sensible Com• Sensible Toa! To Total Temper Capacity Pressor Ratio ISM pressor Ratio ISM ap MotorDry Bulb l�^g pressor Ratio ISM Cool^g pressor Ratio ICapacity S/Tl ��� Dry Bulb Watts Motor pry Bulb ature Watts Motor Dry Bulb Watts L/sl cfrn IkW Btuh I^Put 4'C127°C 'C kW Btuh Input 74°d27°Cj80. �° I kFl W Btuh I^Put 4°C27°C185*F kW Btuh ^P 63°F 5901 1250 111.3 38,400 2740 .7a 1.87 .98 (10.91 37,100 ( 3090 I .75 .89 .99 10.5 35,700 1 3490 1.76 1.90 11.00 4°C27°C129°C 110.11 34.3001 3930 1.77 11.00 (17.2°C) 6351 13501111.41 33.800 1 2740 .75 .90 11-001111-01 37,60011 3090 1.76 .91 11.001110.61 3U00j 3480 1 .781 .93 1.D0 .92 10.2 34,800 3930 1.79 685 1450 1111-51 39,300 1 2740 .77 .9211.00111.1I 38.0001 3090 .78.93 1.00110.7136,6001 3490 .80 1 .95 11 mll .9411.00 10.31 35,2001 3930 1.81 1.9611.00 °F 590I 12501111.91 40,7001 2760 1 .571.71 1.84 111.5139.3001 3110 1.581.721.86111.11 37.800I 3500 1 .59 1.731.97 110.6136,300 1 3950 1.60 1.751.89 119.a°C) 51 13501112.0 141,0001 2760 .58 1.73 I.87 11.61 39,7001 3110 1.59 1.74 1.88 1 11.21 38.2001 3510 1 .501 .751.90 110.81 36.7001 3950 1.61 1.77 1 51 1450 1112.11 111.400 1 Z760 1.591.75 .89111.71 40.0001 3110 1.601.76I.90111.3138,500 1 3510 1.611.77 .921 .92 10.81 36,9001 3950 1.621.791.94 71°F 5901 12501112.71 43.200 2780 .d31.56 .59 12.31 41,8001 3130 1.431.56 1.70 111.81 40.200 35M 1.43 .571.71 111.31 38,700 3980 (21.7°C) 6351 1350 1112.81 43,600 1 2780 1.43 .57 .7t 12.31 42,100 I 3130 1 .43 1 .58 I .71 Jill 1 M 600 1 3530 1 . A 1 .58 1 .73 .a41.58 .72 11.41 39.000 1 3980 1.44 1,59 1 16851 NOTE - 1450 1112.91 All values are cross 43,900 caoactr,es 27901 and 44.58 .72 nn nrn ,rr,,. 12.51 a2 500 1 3140 1." 1.59 1 .7 a 1112.01 �e e.,� r.�, .,:, _ _ _____ ___ a0 9W 1 35a0 I .4a 1 .60 I .75 .75 t t51 39300 I 3980 . dd .61 .77 ��fnr+own Outdoor Air Temperature Entering Condenser Coil Enter- ing Total Air I 85°F (29°C) 95°F 135°C) I 105 F la1°C1 115 ° F 146°C) Wet Bulb Volume Total I Corn- Cooling Sensible To Total I Total Sensible Corn- To Total Cooling Total Corn- Sensible To Total Total Sensible Se Tote! Corn emper. Pressor I CapacityP Ratio ISM ressor Ratio ISM Capacity Motor Cooling Pressor Capacity Motor Ratio lS' Cooling g �� pressor. Ratio ISM Dry Bulb Bulb Dry Butb ature Watts Btuh Input Dry Bulb Watts 175°FII80°FIBS° kW Btuh I^Po 12a°g27°Gi29 Motor Ory Bulb Watts I,put Us cfm IkW 5°FI80°FI85°F a°C127°Cl29°C) Watts kW I Btuh Input �75 FII80°q85°F kW Btuh �4°C127°C129°CI I aa°CI27°C129°C 63°F 5651 12001111.7 40,000 2800 .72 .86 .97 11.31 38,700 1 3160 1.73 1.87 1.99 1110.91 37,2001 3560 1.751 .89 1.00) 10.51 35,7001 410 1.76 1.91 1.00 07.2°C1 16351 13501112.01 40.8001 2810 1.751.89 1.00 1 11.51 39.4001 3160 1.761.91 11.00 11.11 37,9001 3570 1 .781-93 11.00 10.71 36.4001 4020 1.79 1.94 11.00 17101 1500 112.21 41.500 1 2810 1 .781.93 11.00) 11.81 a0.1001 3170 1.79 1.94 11.00 111.31 38.600 1 3570 1 .80 1.96 11-001110.81 37,0001 4030 1.82 11.00 67°F 56511200 112.5 a2.6001 2820 .571.70 .83 12.01 41,1001 3180 1.571.71 1.84 1 11.6 39.5001 3580 1.58 .72 .86 111.11 37,900 1.27 4040 1.59 1.74 (19.4°C) 635 1 13501112.7 43200 1 2830 1.581.73 1.861112.21 41.700 3190 1.59 1 .7,1 1 .88 fil,.e1 40,100 3590 1.60 1.75 1.90 111.31 38.400 J .88 4050 1.61 1.77 1.91 710 1500 1112.8 43.800 1 2830 I .60 I .75 1 .90 112.41 42.300 1 3190 1.60 1 .77 .91 1 11.91 40.600 3600 I .61 1 .78 1 .93 11.a 38.9W 1 4050 1.62 1.8() 71°F 565 1200113.3 45.3001 2850 .43 .551.67 12.81 43.700 3210 .43 .561.s81 12.3 42.100I 3610 1.43 .56 .70 11.8 40.400 .95 4070 1.43 (21.7°C) 635 1 1350 1113.51 46.000 2860 1 .43 .57 .70 13.01 AA.400 1 3220 1 .43 1.57 .71 12 5 a2.700 I 3620 I .aa I .58 .73 1 12.01 a0900 1 .57 .71 a080 I 710 1500 1113.71 46 600 12860 as .58 .73 13.2) a5 000 1 3220 i 44 1 .59 1 112.71 43 200 1 3630 1 sa I I 76 11) 11 1 .a4 .59 .7a NOTE - All values are cross capacities and do nnr -i-i......,.I,,.....,,, .7a . _ .60 41.400 4080 .45 1.617.78 Outdoor - VYJ VI�f-�1 Air Temperature Entering Condenser Coil Enter. ing Total Air 85°F (29°C) 95°F (35°Cl 105 ° F(41°C) 115°F (46°C) Wet Bulb Volume Total Cooling g Corn Sensible To Tote) Total ding Corn- Sensible To Total Total Corn Sensible To Total Total Co. Sensible To Total Temper- Capacity pressor Motor Ratio ISlT) Capacity pressor Motor Ratio IS/T) Cooling Capacity Pressor Ratio ISM Cooling g CaPecnY pressor Ratio ISM Dry Bulb pry Bulb 5, �° = Moor W� Input Dry 5°FI80° Bulb °F D °FI80° 8 rY ulb 5°F attire Watts Input kW Btuh Motor Watts Input Us dm IkW Stuh Watts Input 5 F�O� a1CMM „�, F kW Btuh 24°Ci27-9� 44 kW 8iuh 4°C 63*F 4951 1050 101.6139,6001 2740 1 .70 122 1.941 11.21 38.2001 3080 1.71 1.841.95 1108136.8001 3470 1.72 .851.97 1110.31 35,300 3910 1.73 1.871.98 (172°CI 5901 1250 12.0 40.800 2740 1.731.87 1.981 11.5 j9-.-400 1 3090 1.741.88 .99 1 11.1 37,9001 3490 1.76 1.90 11.00 110.61 36.3001 3930 1.77 92 11.00 685 14501112-31 a1,800 2750 1 .77 1.91 11.001 11.81 40,4001 3100 1.78 1.93 11.00 111.41 38.800 1 35M .79 1.95 11.00 110.91 37,200 1 3940 1.96 11.00 67°F 4951 1050 1112.41 422001 2760 1 .55 1.67 1.791 12.01 40.8001 3110 1.56 1.68 1.80 1 11.51 392001 3500 .56 1.691 .82 11.01 37.600 3940 .81 1.57 1.70 1.83 (19.4°C) 59011250 12.7 43300 1 2770 1.571.71 1 .Sa I 12.31 41.8001 3120 .58 .72 1.a5 11.8 40.200 3510 .58 .731.87 11.3 38.500 3960 685 1450 113.0 4a,200 2770 .59 .741.88 12.5 42.600 3130 .601.76 .90 12.0 41,000 3520 .611.77 .92 11.5 39,200 3970 .59 .75 .89 1.94 71°F 495 F1050 11113.2 45,000 1 2780 a2 .53 .65 12.7 43,500 3130 .a2 .54 I .65 123 a1.800 3530 .42I .Sa I .66 11.8) 40.100 112.01 3980 .621.79 5901 1250 1 .51 46,2001 2800 .43 .55 .68 13.11 44,6001 3150 1.43 1.56 1.69 12.61 42,9001 35a0 41.1001 3990 1.43 .43 1.58 .55 1.72 .68 6851 All values 1450 1113.81 are gross a7 000 1 Capacities 2800 and a3 do .58 not J2 (13.31 inrludo 45,40013150 o.,�.......... 1 - ­77-�____ .4A 1 58 1 .73 -___ 12.31 43,6001 ____ __ _ 3550 I .a3 .aa 159 .57I I .71 .75 12.31 41.800 a000 as ,60 I .76 NOTE - w7j 12ACB / Page 24 ► c> e NOTE -For Temperatures and Capacr0esnor shown in tables, see bulietm --000 ing Unit Rating labile Correction Factor Oara in Miscellaneous Engineering Omit section. C.- A eaa�e C Enter ing Wet Bulb eTp azure 671: �,F (19.4°C) 71°F (21.7°C) NOTE -All Total Air Volume Outdoor Air Temperature Entenng Condenser Coil 85°F Total Cooling �paC^y f29°Cf Sensible Com I ressor To Total P Reno ISm Motor Watts °OIry Bulb FF{{ I^p'n .24°C�j°CFI)29°CI 1 3030 1 .73 1.86 1 gal 1 30a0 .761 .90 11.001 3050 .79 .94 I1.001 3060 57I.70I.83I 3070 .59 1.73 1 .87 115.91 3080 1 .60 1 .76 .91 1 3100 I .431.55 .58 3110 .43 .57 I .71 116. 3120 .4a .59 I .7a 117.1 and do not inelune 95°F Total Coo In l 9 CapaF,rty (35°C) Se^b Com• TO Total PreSSOr Ratio Ism W Dry Bulb 105'F Total COOImg Capacityof kW I Btuh 14.01 47,9001 14.41 a9.000I 14.71 50,0001 14.91 50900I 15.2 51.800 15.4 52 600 1 15.9 54.400 1621 55-MO 56.000 1 -__. __ _ _ 141°C) Com. pressor Warts Input 3850 3860 1.781 3870 3880 3900 3900 3930 1 3940 1 3950 I Sensible To Total Ratio (Sm 115°F Total Cooling Capacity Iwo Serlslb� Com- Pressor) Rath ISM Motor Dry Bulb Us 16601 7551 850 660 7551 850 660 755 850 values cfttt 1400 115.21 1600 1 18001 1400I16.1 1600 1800 ta00117.2 1600 1800 are kW 75.5 t5.81 16.41 16.7 17.51 1781 gross Btuh 51,700 52,900 54,000 55.100I 56,100 1 57.000 58.700 59,800 60,600 Capacities Dry Bulb kW I Btuh 14.61 a9.9W 1a.91 51.000 15.2 52.000 15.6I 53.100 54,100 1 16.1 1 5a.8W 1 16.61 56.700 11 57,600 58,4001 Pv�r e�rern. input IZ ° �° 3420 1.74 1 .88 I 3420 .77 I.92 3430 .80 .96 3450 I.57 .71 3460 1.59 .7 a 3470 .51 .78 1 3490 1.43 .56 3500 .43 1.58 3510 .44 1.60 _n.i .... �_.__ 1,99 1 1.001 1.001 .85I 1.89 1 .93 1 .59 1 .72 1 .75 116.41 -__. 4°CI27°Gr29°CI 1 .751 .ga 11.001 .9a 1.001 1 .82 I .97 1.001 .58 .72 .86l .60 .76 1 .91 1114.51 .62 .79 1 .95 1 -43 1 .57 1 .70 1 .aa I .59 1.74 175.51 a5 51 1 77 kW 13.41 13.7 14.01 14.3 14.7 I 8tuh Input 124 FI'°c a5.800 46,900 47.9W 48.700I a9.600 50.300 I 4350 1.77 192 11.00 4360 .90 .96 11.00 4370 I .8a i390 1.59I.741.38 .99 11.00 aa00 .61 .78 1 .93 U10 .63 .81 .97 75.21 15.7 52,000 52.9001 53 500 sa30 .43 4a40 I .0 1.60 4450 145 .57 1 .71 1.75 .62 79 IL- t Enter- '^g Wet Bulb Temper. atureWaatts AirSensible Volum�T- Total&30 UU"KW Air ernperateue 9 Condenser Coil 85°F g ty f29°C) pressor input To Total Ratio ISM 95°F Total Cooling Capalxty kW Btuh I35°C1 �� Pressor watts Input Sensible To Tatal Ratio (Sm 105°FId7°CI Total Cooling ^g Capacity kW Stuh Com pressor MotorWatts In put I Sensible To Total Ratio ISm 115 Total Cooling Capacity kW Btuh ° F {46°C) Conn Mototoor sor Watts Input Sensible To Total _ ISM Rory Us cfrth Dry Bulb 4°Cj29°CI WF I�r"Lr�°�: Dry Bulb 75° 80° 85° 24 Dry Bulb 5°F 80° 85°FI 4� 2 5 d Bulb 80°�° 27°�,� 63°F 117.2°C) 67°F (19.eCI 71°F (21.7°C) 660 755 850 660 7551 850 6601 755 850 All values 14000 1600 78000 1400 15.4 1600115.71 7800 15.91 1a00 16.a 1600 16.71 1800 16.9 are gross 52,700 53,600 54,a00 56.100 13070 000 57,800 capacities 3010 3020 3030 3030 3040 1 3050 3080 I 3090 and .73 .87 .77 .91 .80 .95 .57 .71 .59 .7A .61 .78 431.56 1 .43 1.58 1 a4 60 do not .98114.0 17,900 1.00 14.449,000 1.001 14.71 50,000 .84 14.91 50,800 .88 1 15.21 57.700 .92 111 5.41 52.a00 .58 115.91 54.100 I .72 1 16.1 1 55,000 75 16.3 55 700 Include evannramr 3390 .75 3400 .78 3410 .81 3420 1 ,58 3430 .6() 3aa0 .62 3460 .a3 3470 I .44 3470 1 as rmi til ,. e. .89 .93 .96 .72 1.76 .79 .56 1.70 .58 .61 .99113.5 1.001 1.0011a.t .86 1 1 .90 1 .9a l 115.21 .73 115.51 .77 115.7 13.8 14.3 14,6 1a.7 46.100 3830 .76 47.100 3840 .79 a8,t00 3850 .83 48,800 3860 .59 49,700 1 3870 .61 50300I 3880 .63 52.0001 3900 1.43 528W 1 3910 1 .4a 1 53 500 3920 I .45 .91 1.00113.0 .95 1.001 13.2 .98 1.00) 13.5 1 .73 .87 1 .77 .9 13.9 1 .81 1 .96 1 57 I .71 1 1,1,61 .59 .75 1 14.81 .82 .78 15.01 aa,200 a5,200 4330 1.77 .92 1.00 4340 1.81 96 1,00 46,200 4350 .85 .99I1.00 a7,5001 4370 I .0"2 .79 1 .94 49,800 50.6001 51.2001 aa00 .0 1.58 a410 .0 4a20 I . •U 1 .73 .51 17 .63 1.30 NOTE - 5eN3 LV ) IV = 35 IYS- ing ing Wm Bulb empBM1 ature o3°F (17.2°C) 67°F (19.4°C) 71°F (21.7°C) NOTE -All Total Air Volume Outdoor Air Temperature Entering Condenser Coil 85°F Total Cooling Capacity (29°C) Sensible Com- S Total I Pressor Ratio Ism I Motor W Dry Bulb Input 5°Fry I80°FI85'F 24°CIZ7°C"J9°CI 1 3020 I .73 .97 98 1 3030 1.76 .91 11.001 ( 3040 1 791.95 It001I15.11 3050 .57 1 .71 .34 115.3 3060 59 I .7a ( .88 1 3070 .61 1.77 I .92 1 2080 .43 1.55 1 .68 116.31 3100 .43 .57 .72 31es 4a 160 75 and do rtnr .��I„ae 95°F Total Cooling Capacity kW - I 14.41 49.200 ta.71 50.300 51.4001 57.200 1 15.61 53,200 15.8 54-0001 55,7001 16.6 56.700 16.8 57 a0p e..�.,_-_.__ (351C) I Com- Sensible I r I TO Total I P essor Ratio ISM Motor Dry Bulb n Z4°f(�I80°ff{{85°q °Q27°d29°CII 1 3400 1.74 1.89 1.99 1 3a20 1.78 .93 1.001 3430 1.81 1.96 11.001 3440 58 .72 .85 I 34a0 1 .50 .75 1.90 114.9 3450 1.62 09 .94 1 3470 1.43 .56 .69 1 3490 .a4 .58 I .73 (15.9 3500 I as 60 I .76 __., "_. _ _ _ _ _ 1051F141°C1 Total Cooling Capacity Sensible Com I To Total pressor Ratio Ism Motor 115'F Total Cooling Capacity kW I Stuh (46°C) Com- Pressor Motor Input Sensible To Total Ratio ISM Us cfrn 6601 1400 11a.91 7551 1600 8501 1800I15.61 660 1 1600 115.91 755 1 1800 1 850 t800 1 6601 14001 755 1600 117.2 85i values values are kW Btuh 51,000 15.31 52,200 53.Z00 Sa,200 16.2 55.200 t6.a1 56.100 16.9 57,800 58.700 re a s 5 a gross capacities kW t3.91 1a.21 14.51 1 a.71 15.21 15.71 16.1 Btuh 47,3W 48,4001 49.4001 50.1001 51.000 I 51,SW 1 53500 54.4W 1 55 100 1 Dry Bulb n� I S'F 27°g29°CII 1 3840 1 .76 1.90 11.00) 3860 1 .791 .9411.001 3870 1 .83 I .98 11.001 3880 1 .591 .73 .371 3890 I .61 I .77 1 .92 1 39W 1 .63 1 .80 1 .951 3920 I .43 1 .571 .71 1 3930 1 .44 1 591 741 3940 .45 52 78 115,41 Bulb a'0�W��'1F 13.31 45.300 13.61 46.3001 13.91 47.4003,11 1 1340 1 .77 .92 I1.00 4360 1 .81 1.9611.00 1370 1 .99 11m 1 a,1 1 48,0001 4370 1 .59 1.75 1.39 14 a8.800 1 4390 1 .62 1.78 1.93 1,1.51 ag,500 aaOD I .6a I .82 197 15.01 51.2001 u20 .4.58 1.72 15.21 52.0001 u30 1.44 1.60 1 .76 52.7001 .1440 45 1 .63 1 ?0 .nwnr.. .-VV+v - �QQUIVI-4I Enter- m Outdoor Air Temperature Entering Condenser Coil 85'F (29°CI 95°F 135'C1 I t05'FIa1°CI � 115 ° F (46'C) ing Total Air Wet Bulb Volume Total Cooling Com_ Sensible TO Total COT' Sensible TC To Total Corr Sensible Total Sensible Temper-�� Motor Pressork4*CZ*CM9-Cj tio 1ST ry Bulb Cooling Capacity Per Motor Ratio Ism Cooling GP�rtY pressor To Total Ratio ISM Cooling Com- P� To Total Ratio Ism azure Watts Dry Bulb Capacity MotorDry atts_F54� Motor Bulb _ 75° 80° '�° kW B� WPut-0°�j� Us cfrn kW Btuh Input85°F kW Btuh Input FI Watts °FF 80°F85' 2 71 kW Btuh I Input 63rF (17.2°Gi a95 590 1050 12 8) 1250 732 43,600 a5,100 3010 3020 1.68 .80 1.91 1 12.31 42.100 3400 1.69 .81 1.92 _11 1131 40,500 3840 1.70 .83 .94 1 11..l 38.8001 4350 .71 .84 1.96 685 495 14W 1113.61 1050 137 46.300 46.700 3030 30a0 .71 .74 .84 .88 .961 12.7 .99113.1 1 13.21 43,500 a4.700 3410 3420 .72 .75 .86 .90 1.97 112.3 1.00112.6 41.800 a2900 3860 I.73 3860 .77 .87 .92 1.991 tm 11.8 1 40.1001 12.0 41.100 a370 1370 .75 .89 .78193 11.00 1.00 6TF (19.4°C) 590 1250 114.11 a8.100 3050 .55 .66 .77 13.61 45.000 46.400 3430 1.55 .66 .78112.7 43300 3870 .55 .67 .79I 12.2 at,500I S61.68 81 685 �'1050 1450 1a.a 1a.6 49.200 49900 3060 3070 .56 .58 .� .72 .81 .85 13.9 a7.d00 34ao 3450 .57 .58 .70 .73 .82 1 13.1 .87 13.31 a4,600 45,500 3880 .57 3890 .59I98112.81 .71L.84, 12.5 42.700 43.6001 4390 4U4W .58 1.72 .60 .76 1.36 71°F (21.7°C1 590 1250115.0 51,300 3090 .42 .52 63 1a1 48.200 3460 a2 .53 .64 1 136 afia00 3900 .a2 65 1 13.01 A. u10 .42 1.54 1.56 5 values t a50 15.d 52,4()0 3100 a2 a3 .54 56 .66 1a.5 59 1d 8 49.600 00 50 6 3a70 340 .43 .55 57 .67I 14.0 70 14 2 a7.7001 48 6W 3920 I.43 3930 -i3 .55 58 581 ?2 113.6 13.41 15.700 I a6.500 u20 1ddQ .43 .56 159 173 .a9 NOTE -All are gross capacities and do not include evaneirnmr -.,d r l ..,e... .. _.._�..� __ is 12AC13I ?age 29 ► ,t �R O F - ror remoeratures and Caoaunes not snows in raoies. see owlenn -Cooling Untr Raring raoie Corre'etion Factor Data ,n Misceilaneous cngineenng Data secudn. 12ACS60 - CR26-65fN11w1 Enter- I Total 1 85'F (29°C) !I 95°F (35'CI it 105'F141°C) :I 1151F 146'C) ing A' Bub I vo uime I Clin I Com• 1 To Total = i Corn. i To Total I Total 1 SensibleI C. Sensible Total Sersible ! 1 I To Total Com• To Total Capacity Ipresswi Ratio ISM I MovaC�li� pressor) Ratio ISM , Cooling Ipnesswl Reno ISlT1 'I filing pressor, Rano IS/TI G D ! W or ; Dry Bulb Goauty ! Motor ! Ory Bulb ! GOa� Motor O�ulb azure I.J. cfm IIkWI Btuh Input p5°FI80°F1ffi'FIIkW Stun Inou�t ;75°Fl80°Fi85'Fi I� 75'F180°Rffi'FlI Warts I75'Fi80°RgS�FI 1 241C77°C29'CI i Z4°C27°G29°gI kw Huh Z4°CI27°C29'C11 kW I Stun ! nPut 24°C.27°C29°CI 631F 18501 18001116.71 57.000 13870 1 .74 1.88 1 .99 1116.11 55.100 1 4.360 :.75 1.39 11.001115.51 53.OW 1 A930 ' 76 1.91 11.00111a.91 5().8001 5550 I .78 1.33 11.001 (172°C)I9451 20001117.01 3-7.9001 3880 I .761.91 11.001116.41 56.000 1 4370 1.78 L93;1.00It15.81 539001 4940 1 791941100111521 5111001 5560 1.31 1.96 11.001 110401 2200111,.21 58.800 1 3890 , .791.94 11.001116.61 36.800 1 4380 1 .30 1.95 11-DO 1116.11 5A,8001 1940 1221 .97 11.001115.41 52.6001 5570 1 .33 1.99 11.00 7°c 850 1 1800 1117.71 60.A00 13900 1 .58 1 .71 1 .85 I1 17.1 ! 58.300 I 1 00 1 .58 1 .73 I .36 11 16.41 56.100 I 19W ! .59 1 .74 1 .38 11 15.81 53.8001 5590 I .50 1 .75 1 .90 (19.4°C)j 945 1 2000 1117.91 51.200 1 3910 I .59 1.71 1 .38 1117.31 59.100 I 1A10 ;.50 1 .75 1.90 1116.71 569W 1 4970 51 1 77 ! 91 1116.01 54.500 1 °590 1 51 ' 79 133 I10101 2200 1118.11 61.900 1 2920 1 .50 1.77 1 .91 1117.51 59.800 1 "10 1.61 1.78 1 93 II 16.91 7.-;W 1 a970 ! .52 1 .79 1 .95 11 16.1 1 55.100 1 5600 ! .53 1.31 1 .96 1 71°F 1 850 1 18001118.31 64.300 1 3940 1 .43 1.56 1.59 II 18.21 62.100 1 1430 i .43 1.57 1.70 !I 17.51 59.800 1 50M I .13 1 .57 1 71 1116.81 57.300 1 5620 I . A I .58 I .73 I (21.7°C)1 9451 2000 1119.11 65.1001 3950 t A3 ! .57 1 -72 II 18.A 1 52.900 I ASAO a 1.58 1 73 1117.71 60 5W 1 5000 4A i 59 1 71 11 17 01 S8.0001 5630 AA 1.50 ! 761 10A01 2200 1119.31 65.800 ! 3950 AA I .59 ; 71 1118.51 53.50()1 1450 ! 1 50 1 76 1117 91 61 1001 5010 A5 1 31 1 -7 it 17 1 1 58SM l 56AO 1 15 ! 52 1 79 NOTE - All values are gross capacities and do not include evaoorator coil olower motor neat deduction. 12AC860 - CH23-65 Enter- Total I 851F (29°C) II 95°F f35°CI 105'F(At°C) 115°F (46'Ct ing Air I Sensible Sensible Sensible BWet ub Volume �owi Com- I Sensible j Towl I Total i I Total To Total I (Gm- To Total Com• 7o Totai I i Cam- I To Tote( p 9 prM�orl Ratio Ism Cop li :pressor I Ratio l5/Tl Cooling Pressor) Ratio I: ! ling pressor Temper- Capacity G a Motor Motor Capacity Ratio ISM ature Water Dry dull j' Water I Dry Bulb ! Watts Ory Bulb j Motor Dry duib Us, cftrl II kW I Stun Inp� 4°C27°Ct29'CII kW I Brut, Input 12..a27°RBS' I kW Btuh I Input 1i24'CS27e=99'C(I kW I Bruin I Input 124°C:271C291C 53°F 1 850 1 1800 1116.61 56.700 1 3860 1 .75 1.89 1.99 II 16.1 1 54,800 1 4360 1.76 1.90 11.0011 15.31 52,3001 A920 1 . % .92 11.00 111 a.91 50.7001 5540 1.78 1.94 11.00 (17.2*0945 1 2000 1116.91 57.700 1 3870 1 .77 1.32 11.0011 16.41 55.800 1 4360 1.78 1.93 :1.001115.81 53.8W 1 t930 1 30 1 .95 11.0011 15.I 1 51.6001 5550 1.81 1.97 11.001 11OA01 2200 1117-21 58,6001 38M 1 .80 1 .95 I1.0011 16.o" 1 56.700 1 1370 i .81 1 .96 11.001116.01 54.600 1 4930 1 331 .98 1 1.0011 15.11 52.5001 5560 1.8A 1 .99 11.001 67°c 1 850 1 1800 1117.51 60.000 1 3890 .58 1.77 1 .86 II 17.01 58.000 1 !390 ! ..4 1 .73 1.97 1116.31 55.700 1 1950 1 59 1 .7 5 1 .89 11 15.7 ! 53.5001 5570 1.50 1 .'6 I .91 (19.0C) 9451 2000 1117.81 60.800 1 3900 ! .50 ! .75 1 .89 1117.21 58.700 ! 140 i .50 ' 75 1.91 it 16.61 56.5001 A960 51 1 .781 .92 ' lb 110401 2200 1118.01 61.5001 3900 .61 1.78 1 .92 !117.11 59,400 1 1a00 ! 62 :.79 194 II 16.71 37.100 i *60 531 90 14 111fi 1 1 54.8001 5590 54 132 i 97 1 71°F 1 850 1 1800 1118.71 63.700 13930 J 1.56 1 70 II 18.1 ! 31.600 1 1420 ; ._3 1 .77 ! .71 1117.A1 59.300 1 1.980 431 .381 7 --- (21.7-C)i 9a5 1 2000 1118.91 64.500 1 3940 m 1 .58 1 .73 1! 18.31 52.a00 1 130 _ 1.59 !'a 1117.51 50.000 1 1990 1 .60 i 75 1116.91 57.6001 5620 1.45 1 .51 ! .77 110401 2200 1119.11 65,200 1 3940 1 .41 .50 1 75 1118.31 53.000 1 1sA0 ' aA 51 ' 77 1117 81 50 6W 1 5000 a5 152 ' 78 It 17 01 58.1001 5620 ' "5 i 53 180 vOTc - All values are gross cadaciries and do not include evaoorator coil olower motor neat deduction. ��� 12ACB60 - C829M-61 Outdoor Air Temoerature Entering Condenser Coil Fitter. ' Total 85'F 129°C) 95'F (35'C) ! 105-FIA1'Cl I 1151F fafi'C) We[ air Total Sensible r Total Sensble Sensible Sensible Volume ! Com- To Total ! Com• To Total Total Corn- To Total ! Tom) ! Com- I Ta Total Bulb 1 I Cooling IPr�orl Ratio ISM i Cooling Ipressorl Ratio ISM 11 Coaling :Pressor( Ratio lSR1 i� Cooling !pressor Ratio ISM remper•1 II Capacity ! Motor ! ,I Capacity ' Motor "-� Gpa , Motor Ca� 'Motor f-- aTure _ Dry Bulb ,I Ory Bulb I Dry dum -Dry I Us I cirri (kW Stun ; nput 75'"Iff t85'FII kW I Btuh � nowt 175'Fl80°Rffi° kW I Btuh n� 75'F180°F85'Fl kW I Stun Input Us! 75'F180°F185°FI 1 7a°CZ71C29°C ,24°C27°Ct29°C!I I 241CI27°C29°C!I I �4-ClE'c29°CI ,331F 1 825 I , 750 !116.61 56.500 1 3890 I .74 1.38 1 .99 It 16.01 54.700 1 4390 ! .75 1.90 11.001115.a1 52.700 1 A960 .77 1 .91 11 .001111.81 50.5001 5600 i .78 1 .93 11.001 (17.2°C)1 850 1 1800 1116.51 56.700 1 3890 75 1 .39 1 99 11 16.1 1 54,900 1 490 176 1.91 ; t 001115.51 52 9W 1 1960 i ' 32 ' t 0011 1 -'-91 50.800 1 56M 79 134 ' t ^01 1 875 11850 1116.71 57.000 1 3890 ! .75 1.90 11.0011 16.1 1 55.100 ! -00 ! .77 Al 11.00 it 15.61 53.1001 t970 7 8 133 11 0011 1 A 91 31.0001 56M 30 E-5 11.001 °c 1 825 1 1750 1117.51 59.900 1 3920 1 .58 1 .12 1 .35 1117.01 57.900 1 a420 .3c8 1 .73 1 37 !116.41 55.8W 1 1990 1 59 1 .71 1 .38 If 15.71 53.500 1 5630 '..50 I .76 I .901 119.4°C) 1850 1 1800 1117.61 60.100 1 3920 ! .58 1.72 1 .86 II 17.01 58.100 1 "30 1.59 ! .7.1 1.38 1116.aj 56.0001 5000 ; .501 .75 1 .39 11 15.7 1 53.70(31 5630 i .50 1.75 1 .91 18751 18501117 71 60.300 1 3920 1 .59 1.73 1 .37 1,117.1 1 58.300 1 �30 1 4-9 7a 88 1116.51 56.200 I 50001 50 176 190 11 15 81 53.8001 5630 151 1.77 i 92 711E 18251 1750 1118.71 63.800 13960 ! .i3 I .� I .a9 II 18.1 I o"1.700 1 1A60 i .13 1 _57 1 .70 1117.af 59.400 1 5030 1 .A3 1 .38 1 .72 II 15.71 57.000 1 5660 i .44 ! .59 1 .73 1 (21.7*01 850 1 18M 1118.81 54.000 1 29W 1 .43 1 .7 1 .70 1118,1 1 61 900 ' a460 113 5-7 171 1117.51 59600 1 5030 1 158 i 73 1116.81 57.200 1 5670 4A 1 59 I 7a 1 1 975 1 1850 1118.81 134,200 1 39W 1 43 1 57 1 71 !1 18 21 U. 100 1A60 1 13 1 58 1,72 If -7 51 59 8W 1 °030 A) -9 f 73 11 tfi 81 57 a(30 1 5670 -4 ! "-3 1 751 40TE - all values are gross caoacines and do not include evaoorator coil blower motor neat deduction. 17ArRr.n - r'Q,7anAsc �I Outdoor Air Temperature Entering Condenser Coil atur95'F Enter -Enter -Total 85'F (29°CI 'I !35°C)II 105-FIA1°CI 146e C) Sensible I Sensible Toil SarTotal Total Total Total I Com• To Totals Con - To Iota( Com- I To Total Gm- To Tool Cooling I 1 Wet volume I Temper- emper- attue I !pressor) Ratio ISRI Cooling pressor) Ratio (Slit I Cooling pressorl Ratio ISM Caolinq Ipressor! Ratio ISM Ca-crty i Motor I Dry Bulb )� Capacity M-r 0 Goau[y Motor GPaaN Motor ry Bulb � Dry Bulb I Dry Bulb kW 1 Btuh 11nPut fii-F180°C29°CII kW I Stun 1 nwtc I75'FI80°Rffi°FlI kW 1 kW i Btuh Input I n� Us I efm II ¢a°C2/°C>Z9°CIj IZa Brun 1 2,.C:27°C29'Ci q°CIz7°CJ9°C 83'F 17551 16001116.31 55.a001 3970 1.721.361.971115.71 53.7001 1370 1.731.871.98115,21 51.7001 1940 1.751.891.991114.51 49.6001 SVO 1.761.91 11.00 (17.2.01 850 1 18M 1116.61 56SM 1 3880 1 .75 1.89 1.99 1116.01 54.700 1 AM 1 .7 6 191 11.00 1115 41 52-700 1 1950 177 1.92 11 001114 81 50.6001 5580 179 134 11 001 19451 2000 11169! 7.500 13890 (.77 1.92 11.0011 16.31 55.600 I i990 !-79 1.94 11.001115.71 53.600) A960 I .90 I .95 I1.0011 t5.t t 51.5001 5590 1.82 1.97 11.001 i71F 17551 16M 1117.31 58.900 1 3900 1 .7 1.70 1 .83 1116.71 ;7.000 1 AA00 ! .57 ! .71 1 .84 1116.11 54.900 1 A970 1 .38 1 .72 1 .36 II 15.a1 52.700 I 5600 I .59 I .73 1 .37 I (19.4,C)i 8501 18001117.61 59.9001 3910 1 .58 1 '2 ! .36 II 77.01 57.900 1 AA10 !.59 1 .74 I .88 1116.41 55.8001 4980 1 .50 1 .75 1 .39 11 15.61 53.4001 5610 1.60 ! .76 1 .91 1 945 1 20001117.81 60.700 1 3920 1 .60 1.75 1 .99 1117.21 58.6001 4420 1.50 1 -76 1.91 116.61 565W 1 A990 1 .31 1 .7811 .32 1115.91 54.1001 5620 1.62 I .79 1 .9a 711E 17551 1600 1118.41 62" 1 3940 1 43 1.36 1 .7 It 17.81 50.700 I sAAo I .A3 156 I .68 II17.1I 58.500 1 5010 1 .41 .56 1 .70 II 16.51 56.2001 5640 ! 1.57 1 .43 .71 (21.71C) 8501 18M 1118.71 63.700 1 3950 1 .i3 137 1 70 1118.11 61.700 1 AA50 ! 43 1 .57 1 71 111741 59.4W 1 5020 1 sA 1 .581 .73 II 16.71 7.000 1 5650 1 1.59 1 .4A .71 1 9a5 1 2000 1118.91 54,500 1 39M 1 4A 1 .58 1 73 1118.31 52 400 I AAW u 1 59 1 74 II 17 51 60.100 ! 5020 1 u i �0 1 75 II 15 91 57 5W 1 56W ; 15 ' 41 1 77 Mi"I' C: _ All .. I..e- -s ,....... __- - __� "_ ' __ _.._ __ _. _.�.,,,-„ �-o....,ow• w.. uwwcr �r,urur scar uaaucnan. 12ACS i Page 34 ► / r=--T_ SUPER EAGLE - RESIDEPJT1AL GAS WATER HEATER Available in 40, 50, 75 and 100 Gallon Gas Models. Ultra High Performance, High Efficiency and High Recovery 5-Year Limited Warranty' on Tank m 5-Year Limited Warranty' on Parts w 2" of Polyurethane Foam - Non-CFC Fused Ceramic Shield Tank" Unique Flue Baffle Design Set and Forget Thermostat Additional Side Openings for Combo- _ Space Heating �...s... • Factory -Installed Side Temperature :._ and Pressure Relief Valve y • Aluminized Steel Multi -Port Lo-NOX Burne 914 for Natural Gas - Cast Iron for Propane PROLine' Super Eaggle' S-Year' Gas Oimmms in all a= s ows m Irx nes. PRQ+i/ i G52-40T60-4NV G52-50T63-4NV G52-75T75-4NV G52-100T88-4NV 'b.-iJwJl•.W.1f» :� At.UIM � •!PT I A a C H K G524660-SNV 40 / xi.000 n7.000 0.; 50.; 5r i3 :0 :912 21'( 71.70 761,0 —.0111111111 Gil i5i7i +cw 5 4500 rt .50 r6.0 73.0 X.51 i3 t2 =5 do z'2 Sc Above models are natural gas. ra Order crcoane rnocals. Cr'.ange 'N' ;urhx :a -?' ur ix. "Canted warranty on tanx ana carts. C=owe cacaos cn manual. x 3 t PAGE 162 SECTION i GAS WATER HEArERS APRIL 1996 Rated Rated tat Hr Stage Rcyy Ist Hr Storage RcwV Model (Foot Rating, Energy VoNuno. snout EtfeY.[Number Mode( (Fact Rating, Energy Volume. Inout Effcy Number Natal Geis Factor Gals McT15H X Nate► Gels Factor Gab MSTVH % AMERICAN WATER HEA7MI GROUP (CONT[]1 D G32-40T34-1N it.Z)s i] .52 40 34.0 77 Gi1-40T14- M (I,ZIs 53 .52 40 34.0 T 7MI440TiSMS (A.Z1 93 .52 AO 34.0 77 461440TISN9 (A.Z) 53 Az 40 3A.0 77 A1(440TIOSM6 (A.Z) 53 .Sz 40 I4.0 ?7 A1t440T1QSN9 (A. -'I i3 .32 40 34.0 17 711I44Cr3SH6 (A.Z) 53 .i2 40 34.0 T 4 7A1440T3SN9 (A, -'I 5] .52 A0. 34.0 T GiQt-a0S40-]N IZ)s i3 .55 40 40.0 76 G1Qt-a0710-IN {2ls 59 .55 40 40.0 79 6i1-40S40-IN (ZI i9 .56 40 AO.O 76 G11-a0T40-1H (Z) 59 .55 40 A0.0 79 G3t-40S4Q-IN (2) i9 .55 40 10.0 7fi G31-40T10-]N IZ1 i9 .56 40 AO.0 79 Gal -40S40-3R (Z)s i9 .15 40 A0.0 75 Gil-A0140-314 (Z1s 59 .56 40 40.0 79 G102-40340-114 (Z)s 59 .17 40 44.0 75 G11-40540-IN (210 $9 .57 A0 A0.0 T5 G52-403AC-114 (Z Is i9 .57 40 AO.G 75 G32-40340-3N (ZIs i9 .57 40 40.0 75 AMIA033SSMS (A,Z1 59 .53 40 All. (I T5 G101-Aor4o-1N (21s 53 so 40 10.0 79 GIZ-ACT40-IN (Z) i3 .50 40 to.a 79 G31-AOT40-3N (Z) i9 .50 40 40.0 79 G3Z-40T40-24 (Z) 53 .50 40 AO,O 79 PHCC40 (A) 53 at AO 14.0 19 OVG102-S0r42.3H 10,2!s TO .57 So 4Z.0 7fi QVG1Z-S0TAZ-3N (0.11: 70 .37 50 42.0 76 0YG32-5QT42-iN (0.21s 70 .57 s0 4Z.0 76 OVG82-50T42-1N (0.Z1s 70 .57 5) AZ.O 75 G101-AOT45-414 (21: 74 .5fi 40 46.1 71 Gil-40T48-AN (2) 71 .55 Ao AS.Q 11 G31-40T45-AN (Z) 74 .56 40 4d.0 71 G31-40T46-AM (Zls 74 i6 40 46.0 15 (3102-401*16-4N (Z]$ 71 Sg 40 46.0 71. G11-40T46-atl (Z): ?4 Sd AO 46.0 1-e GSZ-40T46-AM (Z)s 74 S8 W 46.0 -E Gi2-40T45-4N (Zls 74 S8 40 16.0 71 PYG102-40TIC-I14 (C.Z1: 73 .50 A0 50.0 P5 PVG1Z-AOT30-I?I IC._): 74 .50 AG 30.0 75 PVG52-40TIC-22/ (C.Z): 74 s0 AO -40.0 71 7VG32-40TS0-3N (C.ZI: 74 .50 40 50.0 75 710031SH6 (A,Z1 1-5 .57 50 13.3 'S RK3031CSNt (A,ZI 75 .57 s0 11.0 15 7MI5075SN8 (A.Zi 76 .17 s0 11.0 15 7MI4505132i9 (A.Z! is 5o 510 32.0 73 INI450SICSH9 (A.21 73 .50 5G I8.0 75 7MI450355249 (A.Z) ?s So SO ]8.0 75 G101-50r40-3.4 (ZI; 79 .54 s0 40.0 75 G11-50TA0-!N (2) 79 .14 So Ao.O 75 G51-50T40-IN (Z1 79 .14 s0 40.0 75 G31-50TAC-311 (Zls 73 .54 50 10.0 75 GS01-5073d-1N (Z! 79 .35 50 iE.O -1 Gtl-50T15-111 (Z) 71 .53 so 28.0 71 G31-507.E-3N (Z) 19 .!a SO 3.0 71 G3I-50T33-114 (2) 79 .53 s0 19.0 i1 G102-SOTAC-114 (Z)s T9 .57 SO 40.0 ?5 G12-i0T40-?N (Zls -3 .57 So 10.3 'fi G32-50TAC-311 (Z)s 79 S7 s0 AO.Q -5 G32-10T40-3N (21s 79 .57 So AC.0 75 G1132-50T3a-3N (A.1,2) 73 .i0 io I1 A 71 02-WT11-3N (A.1,21 73 .50 s0 31.0 71 1 G32-50T31-3N (A,:,2) ?1 .30 50 21.0 71 • G22-50T23-!H ;A.1,21 79 .so So 33.3 -1 P+CCZQ (A) 73 .50 113 I1.0 1fi G32-a0Tfi0-aN (Z) Is .54 40 io.0 75 G10Z-A0T3Q-AM (Z): i6 .17 40 Z.a -5 G12-4orso-AN (Z) (5 .57 4a io.0 76 G32-a0T5Q-sN (Z)s i6 .37 40 i0.0 ?S G101-SOTSO-AM (Z1 37 .!A 50 10.0 -5 Gtt-SOTSO-AN (Z) 17 A 4 50 �G.0 78 GS1-50TSO-AN (ZI iT S4 SO So.O -5 G31-1OTS0-4N (Z)s IT .34 i0 A.0 -5 AW50455SN8 (A,Z) 37 S4 s0 -to.0 75 G102-507`50-1N iZ): iT .57 50 50.0 75 Gil-50TW -AN (Z)s 47 .5T 50 50.0 75 1 G52-S0TSQ-AN (Z)s 17 .57 50 30.a 75 G32-50T30-4M (Z)s 17 .57 S0 50.Q 15 9VG10Z-4-0TS3-1N (C.Z!,: iS at SO 53.5 75 PYG12-'.0T53-IH (C.Z)s 35 .51 50 13.i /3 PVG31.5QT1f3-3H (C,Z)s i5 .Sl so 53.5 73 DYG82-10T53-?N (C.Z)s i5 .31 50 13.5 71 Gi02-SOT53-AN (Z1 36 SS So S3.0 75 A/MERICAN WATER HEATER GROUP all-SCT53-AM :Z:: i6 .35 ;S2 5075]-aM IZ!: 36 .55 G22-ioi33-tn (Z!a i6 .53 G102-?5T73-AN (Zls 120 at (CONTOI SQ 50 to iS 33.a i3.1 i3.0 % .5 75 ?S 76 7S G32-7Sr7S-AM 1Z!: I:w it 73 it.5 754 PtGS02.75T7S-IN (C.ZIS 120 .51 73 4.5 75 PVGtZ-TSr73-iN (C.ZIa 12C at 73 74.5 75 NGSZ-11T73-311 (C.ZIa Im it 73 74.5 75 MAZ-TST73-3N (C.:18 I= at 73 74.5 75 34004NE is G101-t9TZ1-3P (ZI 42 .53 f9 ZI.0 77 Git-f9T21-3P (Z) AZ Si 19 ZS.Q 77 131-19T21-311 (ZI 42 .59 19 26.0 77 Gat-f9T23-311 (ZI 4Z .59 (9 Z5.0 77 IWSGtt-101`10-311 I3.Z1 49 .57 IO 30.0 75 41SG51-?OrI0-iP (9.21 49 .5T IQ 10.0 73 GtOt-20510-lP (1-1: s0 .58 M Z7.0 75 Gtt-IC330-27 (ZI s0 .1d 30 Z7.a 75 u"St-30530-3P (ZI 10 Al IO Z7.0 75 •tat-10510-1P (Z1: M .3E 10 V. a 75 G102-30530-!P (Z) So .50 3Q Z7.0 77 GiZ-I0330-1P (Z1 Ia :0 10 '7,3 77 GSZ-3032C-3P (Z! io SQ IQ Z7.0 T7 G12-30S30-I9 (ZI 50 .50 io Z7.0 AHGtt-]QT]t 3P (3.21 13 .15 IQ II.Q t! u+GSt-1QT31 1P 13.Z1 13 S5 30 11.0 TS ;101-2953S-!P (Z": '-1 !a 23 33.0 77 Gt1-29S31-3P (V S3 .So. U ;S.O 79 GSi 2953S-IP (Z) S3 .58 ZI 33.0 75 Gat-29213-311 (Z:: 0 .58 Z3 11.0 77 7IO2-2953S-'-P !Z 53 .50 29 35.0 !"Z-29S33-3D (Z!: 53 iQ Z3 15.0 77 GS2-29s31-3P (ZI S3 .50 ZI i1.0 ;a2-'-9S3S-!P 'Z!s S3 .so ZI IS.Q 77 w15C11-s0T3C-3P (3.ZI !A i6 AO 20.a 71 4HSC.3I-aoT/Q-3P (3.Z1 S4 i6 40 I0.0 is Gt01-10T23-3P /2!: S4 .ia IQ 13.0 'S ;i1-30r77-IF :Z1 14 iH Io 23.0 'S �51-/0733-3P !Z1 S4 .18 IQ 11.a '9 Gal-!or33-1P (:!a 5A is io i3.1 7s .14i70T1Cxd :Zl 54 .58 20 i3.0 -5 ;U(.'OTICCXA !ZI 54 id 1Q 23.0 5 7M("QTSC(1 :'1 54 id !0 33.0 S 54 .at iO 13.0 75 ;i2-3073]-IP (Z!: S4 .51 IO 13.Q 'S GS2 lOT3]-IP `Z 14 .51 :D 33.3 ?3 G12-1OT33-'.P fz!: SA it 'A I1.0 75 ri(430TICXE (Z) !4 .57 20 13.Q 75 tH(410T10CX1 Z S4 .32 IO 13,C 79 :Y(410r5CX5 (Z1 Sd .57 10 33.3 TS 4HGtt- 011I !D 3.2! SO 35 to 11,1 73 w1G1t-s0T3i ]P a.27 iQ .55 4a It.O -3 ;201-29r4Q•!P ;Z1: i0 .13 29 :00 'S vit-I9ii^^-?P !ZJs i0 .it ZI 10..C ?5 1S1-!3T40-V (Z1s 50 Al ZI 40.0 5 ;al-29r40-3P (Z1: M .59 Z9 1YGI0Z-4033E-?P 'O.ZIs i0 i9 44 I5.0 -i IYG12-AOS1d -'P :3 - 3Q .59 to is.0 'S 3YG52.40S1d-1P �0.Z1: i0 .59 40 IS.0 -5 1YGa2-4CS21-3P O.Z:= iC .4 AO I5-a -5 1iC2-Z9T10-lP i0 59 19 40.3 73 112 19t10-lP iC i3 23 :O.0 5 G52 29Ta0 !D io 59 29 40. '5 ;a2 29710-7D ' io 59 .3 10.3 5 1101-10223-!P - 5z 5fi sd 33.3 "ti-tOS3]-'_P i2 .3d 1Q 31. ;St-AOS33-IP i21 i2 .SS 40 31.0 ;at•A0533-IF iz i6 10 13.0 G702-A0510 !P (2J= i2 .!T 40 10.0 tI 1t2 aOSaQ-1P (Z:: i2 .5T to 40.1. 'S 1SZ-44040-312 (ZJ= i1 .17 40 10.] 73 122-AoS4o-3F iz 57 10 40.0 7-a 11G1'4333-?P (':: i2 i9 40 13.3 77 GIZ-1033-I1; •Z1: i2 .59 10 33._ 77 ;S2-=33-1➢ (Z:: i2 .59 10 13.0 77 iiz-10333.3P iz .59 40 13.3 ;t01-AOT21-!P Z1: i3 iT ;it- 0T24-lA 53 .17 40 34.0 ?7 ;SI-A0734-1P i-. i3 S7 40 IA.- 17 BERNER ELECTRIc ►++ RIELLX 4booi - 69i24/93 12:10 V9097341IZ4 BUILDER: RIELLY HODS jOs N W5: THE LEGENDS PLAN: 1 CITY: PGA WEST COUNTY: RWERSIDE DATE: 9-24-M L(GH1TNG LOAD AT 3 WATTS PER 2113 . T- _ 63M WATTS 3".it� WATTS SMALL µ�rpL1ANCE LOAD 2 AT"1 WATTS = 1500 WATTS LAUNDRY 1 AT 100 AT 1200 WATTS a WATTS 1200 WATTS FAO GARAGE DOOR OPENER 1 2 AT 1200 _ WATTS _ 2400 WATTS 16600 WATTS DISPo9AL / DISHWASHER 1 AT 15w AT 00 WAITS — WATTS 1500 WATTS MICROWAVE 2AaV CObKCOP 1 40 AT 00 _ WATTS 0 WATTS a WATTS a4v SINGLE OVE1� 6 1 AT 4000 AT 5000 WATTS = WATTS 5mu WATTS 2V DRYER 240V WATER HEATER AT 5000 WAS = 0 WATTS 0 WATTS 140V RANGE 1 AT 6W0 AT mm WATTS = WATTS MW WATTS 240V DOUBLE OVEN SUB TOTAL WATTS = 30439 WATTS FIRST 10,000 WATTS AT 1W% = 1woo WATTS 9AI,ANcE 2WQ AT 40% 8176 WATTS 240V AIC AT 15oo WATTS PER TON 75M WATTS GRAND TOTAL WATTS = 25676 WATTS = 108.98 AMPS GRAND TOTAL WATTS ! 240V DRF.F'AR® BY: pm"W* 8EMRC Mom. iG ROAD. SE A 75 FAV GMAD PLUM 3123 RESEACH WAY 2625 6• GA° SURE poRof* Ci. 01719 WIRSGN CRT. NY. brM N�1l� �+ W. ®mG QFFXE (gUff)1"4171 QFFIrt MW P0405 oat (7cm m2-wo FAx moM 734-1724 FAX (7= FA K (M 8434� uCENGE 04H= tjcm5E MOW LIGp"K edbm 09l24%98 THU 14:36 FA_X 949 719 4976 RIELLY HOMES INC [a 003 09/24/98 1P:10 9$9097841724 BERNER ELECTRIC -+4� RIELLY IM 002 BUILDER: RIELLY HOMES JOB NAME: THE LEGENDS PLANS: 2 CITY: PCB/► WEST COUNTY: RMRSIDE DATE: 9-24-98 LIGHTING LOAD AT 3 WATTS PER 2483 -90- FT. = 7449 WATTS SMALL APPLIANCE LOAD 2 AT 1500 WATTS = 30M WATTS 15M WATTS LAUNDRY 1 1 AT 1500 AT I:= WATTS = WATTS = 1200 WATTS FAU GARAGDOOR OPENER E 2 AT 1200 WATTS = 2ADa WATTS DISPOSAL If DISHWASHER 1 AT 1500 WATTS 1 SW WAFTS 1500 WATTS MICROWAVE 1 AT 15M AT 4000 WATTS = WAITS 0 WATTS 240V COOKTOP 240V SINGLE OVEN AT 40M WATTS a WATTS 240V DRYER 1 AT 5oW WATTS = SM WATTS 240V WATER HEATER AT 50M WATTS = 0 WATTS a WATTS 240V RANGE AT S000 WATTS 8000 WATTS 240V DOUBLE OVEN 1 AT SWO WATTS = SUB TOTAL WATTS 31549 WATTS FIRST 1o,000 WATTS AT 100% = 100W WATTS BALANCE 21549 AT 40% _ 6620 WATTS a40V A/C AT 7SW WATTS PERTON 9000 WATTS GRAND TOTAL WATTS - 27520 WATTS GRAND TOTAL WATTS ! 248V - 115.08 AMPS PRUP&AM er. 9ERNER MEMO INF. 76 EAST04AM OLVD. 717� AE6E.RGH WAY Z025 E CRA O ROAD, SUrM A CORONA. CA. Ana CARSOM C y. "v. WOO mogrFj MS VCGA6. Nv_ agmu lnC os[ mm 73W 171 a"ry rnz OFFICE gaz 042-0" FAX F o 73a17n4 FAX C= 00-OP QE FAX (04 Aar-0046 viceNms"..9, uCENeS almm UCOa91_93sm 09/24/98 12:10 'BC9097341724 BERNER ELECTRIC 1--- RIELLY BUILDER: RIELLY HOMES JOB NAME: THE LEGENDS PLANO: 3 CfTf_ PGA WEST COUNTY: RIVERSIDE DATE: &-2"3 I.IGNTING LOAD AT 3 WATTS PER 2618 90. FT. a 845�4 WATTS 3000 WATTS SMALL APPLIANCE LOAD 2 AT 15W AT ISM _ WATTS _ WATTS 1500 WATTS LAUNDRY 1 1 AT 120U __ WATTS 12{JO WATTS FAU GARAGE DOOR OPENER 2 AT 1200 _ WATTS 2400 WATTS y5p0 WATTS DISPOSAL I DISHWASHER i AT 16M WATTS = 1500 WATTS MICROWAVE 1 AT ISM AT 4000 WATTS = WATTS - 0 WATTS 2&uV COOKTOP 240V SINGLE OVEN AT 40M WATTS 0 WATTS 240V DRYER 1 AT 50M WATTS = WOO WAITS 0 WATTS 240V WATER HEATER AT WW AT 8000 WATTS WATTS = 0 WATTS 240V RANGE 24W DOUBLE OVEN 1 AT 80M WATTS = mon WATTS SUB TOTAL WATTS 32 S4 WATTS FIRST 10,000 WATTS AT 100% o 10000 WATTS BALANCE 22554 AT 409/6 = 9022 WATTS 240V A!C AT Ism WATTS PER TON 10500 WATTS GRAND TOTAL WATTS 29= WATTS GRAND TOTAL WATTS 1240Y -- 123.01 AMPS PIWARrn ey: gERN_A Q.ECTAC Or - re MAa ORAM ULVD. 3M RESEARCH Wtr 2M G. aura ROAD. 6Urr6 A CoAc", C L arne Wax* rrrr. W. 8B7as NEE z am= OFF" MR) 75�1Ti OFMrz C?QM aM�� FAX (W9) 7164ns FAX d= NW-1-NE FAT, (M im"m LCUMSE 04053S2 UGENOE VXW umwatamo VO/.LY/OV 111V 1Y.V! 1'aa. DYO i1v Yvry A%XLL-A -VY o 111V WJ VVV 0e/24/98 12:10 89097341724 BERNER ELECTRIC jai RIELLY 10004 BUILDER: RIELLY HOMES JOB NAME: THE LEGENDS Pam: 4 CITY: PGA WEST COUNTY: RNERSIDE PATE: 224-as LIGHTING LOAD AT 3 WATTS PER 3= SO, Fr- 9886 WATTS3p00 WATTS 30 SHALLAPPLIANCE LOAD 2 AT 1500 WATTS _ 00 WATTS LAUNDRY 1 1 AT 1 AT 1200 00 WATTS WATTS 1200 WATTS FAU GARAGE DOOR OPENER 2 AT 1200 WATTS _ 2400 WATTS 1500 WATTS DISPOSAL I DISHWASHER 1 AT ISM WATTS - 1SW WATTS MICROWAVE 1 AT 1500 AT 4000 WATTS WATTS 0 WATTS mV COOKTOP 240V SINGLE OVEN AT 4000 WATTS _ p WATTS 5000 WATTS 240V DRYER 1 AT 50a0 AT Wm WATTS WATTS 0 WATTS 24ov WATER HEATER AT 8000 WATTS 0 WATTS 240V RANGE 240V DOUBLE OVEN 1 AT $000 WATTS = 84� WAT TS SUB TOTAL WATTS R 337aS WATTS FIRST 1o,000 wAtTS AT 100% = 1a000 WATTS BAIANLE :z3786 AT 40% 96os WATTS 240V AIC AT 15M WATTS PER TON = Iowa WATTS GRAND TOTAL WATTS - 30006 WATTS GRAND TOTAL WATTS I Z40V - 125.03 AMPS pwwAIa "t BERNER ELECTRIC ING. H 1NA7 Z= F Ci+P1G aCO�i �JI'S6 A C "oi, CA Q Ella, iizz^R RuwAw:MV_ ri9708 No" L" VGGAS. NV. Vg= CORONA CA-Y 11 CME DRY, OFMF; (%=�°3 FAX M I 3 -i d171 FA VEX) ) m 05"-M$Z O Rex � at24Css FAX rmE 73�47K FAX (TGQ mow ucaluE � E L1Cx[� UV24/06 TH.Ll 14: 37 FAX 040 719 4976 RIELLY HOMES INC M 006 09/24/98 12:10 IM9097341724 BERNER i3LECTRIC a+-+ RIEL.LY it005 BUILDER: R1155MY HOMES JOB NAME- THE LEGENDS PLANS: 5 CITY! PGA WEST COUNTY: RIVERSIDE DATE: 9-24-48 LIGHTING LOAD AT 3 WATTS PER 3+409 SC. FT_ = 10227 WATTS 3000 WATTS SMALL APPLIANCE LOAD 2 AT 15M WATTS WATTS = I GDO WATTS LAUNDRY1 LAU 1 AT 1500 AT 1200 WATTS = 1200 WATTS GARAGE DOOR OPENER 2 AT 1200 WATTS = 2400 WATTS 1500 WATTS DISPOSAL I DISHWASHER AT 1500 WATTS = 1500 WATTS AVE MICROWAVE MICR 1 AT 1500 AT 40M WATTS WATTS = x 0 WATTS 240V O 240V SINGLE OPEN AT 4000 WATTS °L 0 WATTS 240V DRYER 1 AT 5000 WATTS = S000 WATTS 0 WATTS 240V WATER HEATER AT 5000 WATTS = 0 WATTS 240V RANGE 1 AT 8000 AT BODO WATTS WATTS = 8000 WATTS 240V DOUBLE OVEN SUB TOTAL WATTS 34327 WATTS >'IRST 10,000 WATTS AT 100% = 10000 WATTS BALANCE 24377 AT 40°% 9731 WATTS WV AIC AT 1500 WATTS PER TON 105OU WATTS GRAND TOTAL WATTS 30231 WATTS GR"D TOTAL WATTS 1240V = 125.98 AMPS PREFAREb BY: 96p1iR GiACS1iIC INC. A 75 6AST 6FAW OLVP, a13>t REBCAMCN IN�7 7NZlS E GRA1G �D. s1JI7E c�ll6NA, Cam. 91710 F-msow CRY, w. -1Od NORiA L&s VEGAB. KV, 89030 OFROE pNI7s�.1' 171 OFF" voz MM-=b FAX r702) bo6S KAx Wo) Tbi-i nd IDS i7a1 2 LpmNs6 a9BeB0 LXM43F/411&= LEENSEi aM UH/24/96 'i'HU 14::57 N'AA.a48 719 497U KihLLY JIUMEb IM( l0uvi 09/24/A8 1z:11) V9o97341724 BERNER ELECTRIC 4-" RIELLY zoos BUILDER: RIELLY HQMEs 4013 NAME: THE LEGENDS P LA1#: 6 CITY: PGA WEST COUNTY: RIVERSIDE DATE: 9 24g8 LIGHTING LOAD AT 3 WATTS PER 369$ J� PT. - a 11094 WATTS 3M WATTS SMALL APPLIANCE LOAD AT 15W AT 15D0 WAS WATTS = 1500 WATTS LAUNDRY 1 1 AT 1200 WAITS = 1200 WATTS FAU GARAGE DOOR OPENER 2 AT 120D WATTS 2400 WATTS 1500 WATTS DISPOSAL.! DISHWASHER 1 AT 1500 WATTS = WATTS 1500 WATTS MICROWAVE1 AT 1500 AT 4000 WATTS _ 0 WATTS 240V COOKTOP 240V SINGLE OVEN AT WATTS = 0 WATTS SOW WATTS 240V DRYER 1 s0W AT 00 W AT WATTS _ WATTSO 0 WATTS 24aV WATER HEATER $000 AT WATTS __ 0 WATTS 240V RANGE 240V DOUBLE OVEN 1 AT 0D0 B WATTS - 8000 WATTS SUS TOTAL. WATTS = 35194 WATTS RRST 1o,000 WATTS AT 1000/6 WATTS 10Do9 BALANCE 2S194 AT 40% WATTS 1ZOUo WATTS 240V AIC AT ISM WATTS PER TON � GRAND TOTAL WATTS = 32078 WATTS = 133.66 AMPS GRAND TOTAL WATTS 1240V MRSFAR®SY: VERNER ELZCTFW LNC 3173 AESG�RCH WAY902M E- CRAP RLUD. 6UI7E A 76 BAbT43pAMD �w- CORONA. CA- 9171 P CARsoN CR7, NY, 907ah MMTH PJ"S. ldV- 99030 o�i08 (9w) 7sss171 omcE 17023 ss F FRCE (0) � N].BOQb FAX (WO) 7344T24 F X vm 8 L!C@N99 "A 6ICEN3t ou"m LICENSE7�0