HomeMy WebLinkAboutBSOL2022-0070ROOF ACCESS POINT
TRANSITION BOX (TYP.)
ROOF ACCESS POINT
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
TO ELECTRIC
UTILITY GRID
C
D & E
C
BFRONT OF HOUSE (FOH)
A
N
ST
O
N
E
C
R
E
E
K
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
0
8
3
4
TO
L
L
B
R
O
T
H
E
R
S
-
S
O
C
A
L
-
O
C
/
S
A
N
D
I
E
G
O
72
5
T
O
W
N
A
N
D
C
O
U
N
T
R
Y
R
D
#
2
0
0
8
0
-
4
6
4
O
L
D
R
A
N
C
H
T
R
A
I
L
N
O
R
T
H
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
OR
A
N
G
E
,
C
A
9
2
8
6
8
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
C002189
RP-194161
2022-02-16
FERLYNE ACLAN
2022-02-16
EOR
PLAN
ROOF TYPE
ROOF PITCH
ELEVATION
ARRAY SQ. FT.
MODULE QTY.
MODULE TYPE
SYSTEM SIZE
STORY TYPE
LOT & ARRAY INFORMATION
MOUNTING &
ATTACHMENT
ORIENTATION
LOCATION
LOT NUMBER
LAYOUT/SCHEME
A (SB)
376 SQ. FT.
21
FRONT & RIGHT
215° & 125°
1-STORY
7.35 KW
4:12
S-TILE
3 - JUBILEE
SPR-X21-350-BLK-E-AC 26
INSET - INVISIMOUNT
4
2PHASE NUMBER
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
L
O
T
P
L
A
N
P
A
C
K
A
G
E
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
(3') WIDE ACCESS PATH (TILE ROOF) / (4') WIDE ACCESS PATH (FLAT ROOF)
DIMENSIONS OF THE INSET ARE LARGER THAN THE ARRAY AND SHALL BE
CONFIRMED BY THE BUILDER BEFORE THE INSTALLATION.
NOTES & LEGENDS
ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR
INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR
BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT.
1
2
1#14
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--#14
3E
D
#6
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
--EGC BARE CU
CU-NM-B
--EGC BARE CU
CU-NM-B
1C
#10
#10
#8
#10
3 NM CABLE OR EQ
INSTALLED IN WALL CAVITY
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
CONDUIT SIZE(WHEN NEEDED)
CONDUCTOR / CONDUIT SCHEDULE
PVA-1
ST
O
N
E
C
R
E
E
K
TR
A
C
T
/
P
A
R
C
E
L
#
:
3
0
8
3
4
TO
L
L
B
R
O
T
H
E
R
S
-
S
O
C
A
L
-
O
C
/
S
A
N
D
I
E
G
O
72
5
T
O
W
N
A
N
D
C
O
U
N
T
R
Y
R
D
#
2
0
0
8
0
-
4
6
4
O
L
D
R
A
N
C
H
T
R
A
I
L
N
O
R
T
H
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
OR
A
N
G
E
,
C
A
9
2
8
6
8
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
C002189
RP-194161
2022-02-16
FERLYNE ACLAN
2022-02-16
EOR
N
80-464 OLD RANCH TRAIL NORTH
PL
A
C
A
R
D
PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
PVA-2
SIGNAGE NOTES
1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT.
2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHIN MINIMUM 3/8" LETTER HEIGHT, WHITE ON RED BACKGROUND.
3. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE.
DR
I
V
E
W
A
Y
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
CAUTION:
MAIN SERVICE
PANEL
LOAD CENTER
PHOTOVOLTAICAC DISCONNECT
PHOTOVOLTAICARRAY ON ROOF
SPR-X21-350-BLK-E-AC (240)21 MODULES/MICRO-INVERTER
INSET (S-TILE)PEGASUS