HomeMy WebLinkAboutPGA West Legends - TR 28838 BTCP0009-020 (Plans 8-9) Title 24 - RevisionsA
r
THE LEGENDS AT PGA WEST
La Cala
La Quinta
CLIMATE ZONE # 15
Revised: Plan 7:
UFAR: f a10a $, PLP44 `1
Western Pacific Housing
South Coast Architects
Ttfis vfLuq- To toot EtAm4y StAADAeDs -p���C.5 Au- '?2V100s%.Y A(?eo\rr-D CN-CS
HERITAGE ENERGY GROUP
October 4, 2002
Title 24 Energy Calculations
(949) 789-7221
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATEAqBY
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R
Project Title .......... The legends at PGA West Date..10/04/02 15:33:29
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
DOCUMENTATION AUTHOR
Name.... Name.... Sam Maimone
Company. Wes n Paci Housing Company. Heritage Energy Group
Address. 16940 Von r n 0200 Address. 15375 Barranca Pkwy, Suite F-101
Iry n CA 06 Irvine, CA 92618
Phone... 9 42-619 Phone... 949-789-7221
License. _
o
1�—Sig d.. to
Signed.
(date) (da- e)
EN,F-ORCKNIT AGENCY
Name .... elll(9 L A Id
Title...
Agency..
Phone...
Signed..
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
--------------------------------------------------------------------------------
--------- --------------------------------------------------------
Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29
Project Address........ La Cala ******* ---------------------
La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field Check/ Date
Climate Zone. ..... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File-21105MG1 Wth-CTZ15S92 Program -FORM CF-1R
User#-MP0940 User -Heritage Energy Group Run-------------------------------------------------------------------------
-
GENERAL INFORMATION
Conditioned Floor Area..... 3118 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 20.7 % of floor area
Average Glazing U-factor... 0.36 Btu/hr-sf-F
Average Glazing SHGC....... 0.34
Average Ceiling Height..... 10 ft
BUILDING SHELL INSULATION
Component Frame Cavity Sheathing Total Assembly
Type Type R-value R-value R-value U-factor Location/Comments
-------------------------------------------------------------------------
SlabEdge
Wall
Roof
Door
SlabEdge
None
R-0
R-n/a
F2=0.510
Wood
R-19
R-n/a R-19
0.065
Wood
R-30
R-n/a R-30
0.035
Wood
R-0
R-n/a R-0
0.330
None
R-0
R-n/a
F2=0.760
FENESTRATION
------------
Over-
Area
U-
Exterior hang/
Orientation
(sf)
Factor
SHGC
Shading Fins
Location/Comments
----------------
Door
Back
(S)
-----
272.0
------
0.350
------
0.330
-------- -----
Standard Yes
--------------------------
vinyl
framed
low-e
Wind
Back
(S)
39.0
0.350
0.320
Standard Yes
vinyl
framed
low-e
Wind
Back
(S)
39.0
0.350
0.320
Standard None
vinyl
framed
low-e
Wind
Back
(S)
30.0
0.350
0.310
Standard Yes
vinyl
framed
low-e
Wind
Right
(W)
95.9
0.350
0.310
Standard None
vinyl
framed
low-e
Wind
Front
(N)
72.5
0.350
0.310
Standard Yes
vinyl
framed
low-e
Door
Front
(N)
48.0
0.550
0.650
Standard Yes
Non metal framed clear
Wind
Left
(E)
48.9
0.350
0.310
Standard None
vinyl
framed
low-e
SLAB SURFACES
-------------
Area
Slab
----------------
Type
(sf)
------
Standard
Slab 1026
Standard
Slab 1628
Standard
Slab 464
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R
Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29
---------------
HVAC SYSTEMS
Refrigerant
Equipment Minimum Charge and Duct Duct
Type Efficiency Airflow Location R-value
-------------------------------------------------
Tested ACCA
Duct Manual Thermostat
Leakage D Type
------- ------ ----------
Furnace
0.800 AFUE n/a Attic
R-4.2
Yes
No
Setback
ACSplitTXV
12.00 SEER Yes Attic
R-4.2
Yes
No
Setback
HPSplit
6.60 HSPF n/a Attic
R-4.2
Yes
No
Setback
HPSplit
12.00 SEER No Attic
R-4.2
Yes
No
Setback
Living: Minimum Heating Load: 13,772 Btuh
Cooling Load:
15,035(Sensible),18,042(Total)
Beds serv.: Minimum Heating Load: 28,431 Btuh
Cooling Load: 26,475(Sensible), 31,770(Total)
Casita: Minimum Heating Load: 10,323 Btuh
Cooling Load: 9,356(Sensible),11,228(Total)
Note: The loads shown are only one of the criteria affecting the selection of
HVAC equipment. Other relevant design factors such as air flow requirements,
outdoor design temperatures, coil sizing, availability of equipment, oversizing
safety margin, etc., must also be considered. It is the HVAC designer's
responsibility to consider all factors when selecting the HVAC equipment. That
individual is required to provide Form CF-6R, an Installation Certificate,
which must be posted at the building site prior to issuance of the occupancy
permit. The CF-6R is not required for permit submittal. It is intended to
insure installation of equipment that meets the efficiency requirements of the
compliance documentation.
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
Equipment Type (% fan CFM/CFM25) (ft2) -----------------
------------------------------------------
Furnace / ACSplitTXV 6% / 43.1 n/a
Furnace / ACSplitTXV 6% / 68.4 n/a
HPSplit / HPSplit 6% / 19.5 n/a
WATER HEATING SYSTEMS
---------------------
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R-value --
---------------------------------------- -------------- ------ ----------
Storage Gas Recirc/TimeTemp 1 0.51 75 R-12
American Water Heater G52-75T75-4NV (or equal)
*All piping used to recirculate hot water must be insulated with R-4 insulation
or equivalent. This includes any recirculating piping located in concrete
slabs or underground.
A timer must be permanently installed to regulate pump operation. Timer
setting must permit the pump to be cycled for at least eight hours per day.
An automatic thermostatic control must be installed to cycle the pump on and
off in response to the temperature of the water returning to the water heater
through the recirculation piping. Minimum differential or "Deadband" of the
control shall not be less than 20 degrees F.
SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system (s) .
Mandatory Measures require a R-12 or greater external blanket on Gas Storage
Water Heaters with Energy Factors less than 0.58.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R
Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29
---------------
HERS REQUIRED VERIFICATION
--------------------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s). If a cooling system is not installed, then HERS verification
is not necessary for the RCA or TXV.
REMARKS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
---------------
Project Title.......... Plan 8 /Plan 8 w/casita Date..09/12/02 11:53:36
Project Address........ La Cala ******* ---------------------
La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field Check/ Date
ClimateZone. ..... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
--------------------------------------------------------------
MICROPAS6 v6.01 File-21105M81 Wth-CTZ15S92 Program -FORM CF-1R
User#-MP0940 User -Heritage Energy Group Run-
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 2823 sf / 3308 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 20.8 % of floor area
Average Glazing U-factor... 0.35 Btu/hr-sf-F
Average Glazing SHGC....... 0.32
Average Ceiling Height..... 10 ft
BUILDING SHELL INSULATION
-------------------------
Component Frame Cavity Sheathing Total Assembly
Type Type R-value R-value R-value U-factor Location/Comments
------------------------------------------------- ------------------------
S1abEdge None R-0 R-n/a F2=0.760
Wall Wood R-19 R-n/a R-19 0.065
Roof Wood R-30 R-n/a R-30 0.031
Door Wood R-0 R-n/a R-0 0.330
FENESTRATION
------------
Over-
Area U- Exterior hang/
Orientation (sf) Factor SHGC Shading Fins Location/Comments
---------------- ----- ------ -------------- ----- --------------------------
Door Back (S) 200.0 0.350 0.330 Standard Yes Vinyl framed low-e
Wind Back (S) 15.0 0.350 0.320 Standard Yes vinyl framed low-e
Door Back (S) 64.0 0.350 0.330 Standard None Vinyl framed low-e
Wind Back (S) 20.0 0.350 0.310 Standard Yes vinyl framed low-e
Wind Right (W) 44.0 0.350 0.310 Standard Yes vinyl framed low-e
Door Right (W) 64.0 0.350 0.330 Standard Yes Vinyl framed low-e
Wind Front (N) 138.5 0.350 0.310 Standard Yes vinyl framed low-e
Wind Left (E) 30.0 0.350 0.310 Standard Yes vinyl framed low-e
Wind Left (E) 12.9 0.350 0.310 Standard None vinyl framed low-e
SLAB SURFACES
-------------
Area
Slab Type (sf)
Standard Slab 1361
Standard Slab 1462
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
Project Title.......... Plan 8/Plan 8 casita
HVAC SYSTEMS
Refrigerant
Equipment Minimum Charge and Duct
Type Efficiency Airflow Location
Furnace 0.800 AFUE n/a Attic
ACSplit 12.00 SEER No Attic
Living: Minimum Heating Load: 21,781 Btuh
Cooling Load: 22,523(Sensible),27,028(Total)
Bedrooms: Minimum Heating Load: 20,719 Btuh
Cooling Load:17,239(Sensible),20,687(Total)
casita: Minimum Heating Load: 8,614 Btuh
Cooling Load: 7,929(Sensible), 9,515(Total)
Page 2 CF-1R
Date..09/12/02 11:53:36
Tested ACCA
Duct Duct Manual Thermostat
R-value Leakage D Type
------- ------- ----------------
R-4.2 Yes No Setback
R-4.2 Yes No Setback
Note: The loads shown are only one of the criteria affecting the selection of
HVAC equipment. Other relevant design factors such as air flow requirements,
outdoor design temperatures, coil sizing, availability of equipment, oversizing
safety margin, etc., must also be considered. It is the HVAC designer's
responsibility to consider all factors when selecting the HVAC equipment. That
individual is required to provide Form CF-6R, an Installation Certificate,
which must be posted at the building site prior to issuance of the occupancy
permit. The CF-6R is not required for permit submittal. It is intended to
insure installation of equipment that meets the efficiency requirements of the
compliance documentation.
DUCT TESTING DETAILS
Duct Measured Supply
Leakage Target Duct Surface Area
Equipment Type (% fan CFM/CFM25) (ft2) -----------------
------------------------- -----------------
Furnace / ACSplit 6% / 57.2
Furnace / ACSplit 6% / 61.4
WATER HEATING SYSTEMS
---------------------
Number
in
Tank Type Heater Type Distribution Type System
n/a
n/a
Energy
Factor
Storage Gas Recirc/TimeTemp 1 0.51
American Water Heater G52-75T75-4NV (or equal)
Tank
External
Size
Insulation
(gal)
R-value --
75
R-12
*All piping used to recirculate hot water must be insulated with R-4 insulation
or equivalent. This includes any recirculating piping located in concrete
slabs or underground.
jA timer must be permanently installed to regulate pump operation. Timer
'setting must permit the pump to be cycled for at least eight hours per day.
An automatic thermostatic control must be installed to cycle the pump on and
off in response to the temperature of the water returning to the water heater
'through the recirculation piping. Minimum differential or "Deadband" of the
control shall not be less than 20 degrees F.
SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------
-----------------------
This building incorporates Tested Duct Leakage.
Mandatory Measures require a R-12 or greater external blanket on Gas Storage
Water Heaters with Energy Factors less than 0.58.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R
Project Title.......... Plan 8/ Plan 8 w/casita Date..09/12/02 11:53:36
--------------
HERS REQUIRED VERIFICATION
--------------------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
HERS REQUIRED VERIFICATION
--------------------------
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the .CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
Project Title..........
Project Address........
I Documentation Author...
-----------------------------
Plan 9/Plan 9 w/Casita Date..09/12/02 12:14:08
La Cala ******* ---------------------
La Quinta *v6.01*
Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field Check/ Date
Climate Zone.......... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File-21105MI1 Wth-CTZ15S92 Program -FORM CF-1R
User#-MP0940 User -Heritage Energy Group Run---------------------------------------------------------------------------
-
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 3240 sf/3816 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 17.3 % of floor area
Average Glazing U-factor... 0.36 Btu/hr-sf-F
Average Glazing SHGC....... 0.35
Average Ceiling Height..... 10 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing
Total
Assembly
Type
Type
-------
R-value
--------
R-value
--------
R-value
-------
U-factor Location/Comments
------- ------------------------
------------
S1abEdge
None
R-0
R-n/a
F2=0.760
Wall
Wood
R-19
R-n/a
R-19
0.065
Roof
Wood
R-30
R-n/a
R-30
0.035
Door
Wood
R-0
R-n/a
R-0
0.330
S1abEdge
None
R-0
R-n/a
F2=0.510
FENESTRATION
------------
orientation
Door Back (S)
Wind Back (S)
Door Right (W)
Door Right (W)
Wind Right (W)
Wind Front (N)
Wind Left (E)
Wind Left (E)
Wind Left (E)
Wind Back (S)
Area
(sf)
268.0
78.0
48.0
48.0
26.8
29.0
108.0
6.7
4.0
45.0
U-
Factor SHGC
Exterior
Shading Fins Location/Comments----------------------------
-
--------------
0.350
0.330
-----
Standard
0.350
0.320
Standard
0.350
0.330
Standard
0.550
0.650
Standard
0.350
0.310
Standard
0.350
0.310
Standard
0.350
0.310
Standard
0.350
0.320
Standard
0.350
0.310
Standard
0.350
0.310
Standard
SLAB SURFACES
Over-
hang/
Yes vinyl framed low-e
Yes vinyl framed low-e
Yes vinyl framed low-e
Yes non metal dual clear
Yes vinyl framed low-e
Yes vinyl framed low-e
Yes vinyl framed low-e
Yes vinyl framed low-e
None vinyl framed low-e
Yes vinyl framed low-e
Area
Slab Type
(sf)
------
----------------
Standard Slab
1384
Standard Slab
1856
Standard Slab
576
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R
Project Title.......... Plan 9/ Plan 9 w/Casita Date..09/12/02 12:14:08
EquipmentMinimum-Minimum-
Type Efficiency - --
Furnace
ACSplit
HPSplit
HPSplit
Living:
Cooling
HVAC SYSTEMS
Refrigerant
Charge and Duct Duct
Airflow --Location- R_value
Tested ACCA
Duct Manual Thermostat
Leakage D Type --- ---
0.800 AFUE n/a Attic
R-4.2
Yes
No
Setback
12.00 SEER No Attic
R-4.2
Yes
No
Setback
6.60 HSPF n/a Attic
R-4.2
Yes
No
Setback
12.00 SEER No Attic
R-4.2
Yes
No
Setback
Minimum Heating Load: 23,016 Btuh
Load: 22,596(Sensible),27,115(Total)
Bedroom/retreat: Minimum Heating Load: 25,424 Btuh
Cooling Load:21,440(Sensible),25,728(Total)
Casita: Minimum Heating Load: 10,979 Btuh
Cooling Load: 10,157(Sensible),12,188(Total)
Note: The loads shown are only one of the criteria affecting the selection of
HVAC equipment. Other relevant design factors such as air flow requirements,
outdoor design temperatures, coil sizing, availability of equipment, oversizing
safety margin, etc., must also be considered. It is the HVAC designer's
responsibility to consider all factors when selecting the HVAC equipment. That
individual is required to provide Form CF-6R, an Installation Certificate,
which must be posted at the building site prior to issuance of the occupancy
permit. The CF-6R is not required for permit submittal. It is intended to
insure installation of equipment that meets the efficiency requirements of the
compliance documentation.
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
Equipment Type (% fan CFM/CFM25) (ft2) -----------------
------------------------- -----------------
Furnace / ACSplit 6% / 58.1 n/a
Furnace / ACSplit 6% / 78.0 n/a
HPSplit / HPSplit 6% / 24.2 n/a
WATER HEATING SYSTEMS
---------------------
Tank Type Heater Type Distribution Type
---------- ----------- -------------------
Number
in Energy
System Factor
------ --------
Storage Gas Recirc/TimeTemp 1 0.51
American Water Heater G52-75T75-4NV (or equal)
Tank
External
Size
Insulation
(gal)
----------------
R-value --
75
R-12
*All piping used to recirculate hot water must be insulated with R-4 insulation
or equivalent. This includes any recirculating piping located in concrete
slabs or underground.
A timer must be permanently installed to regulate pump operation. Timer
setting must permit the pump to be cycled for at least eight hours per day.
An automatic thermostatic control must be installed to cycle the pump on and
off in response to the temperature of the water returning to the water heater
through the recirculation piping. Minimum differential or "Deadband" of the
control shall not be less than 20 degrees F.
SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------
-----------------------
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
This building incorporates Tested Duct Leakage.
Mandatory Measures require a R-12 or greater external blanket on Gas Storage
Water Heaters with Energy Factors less than 0.58.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R
Project Title.......... Plan 9 w/Casita Date..09/12/02 12:14:08
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
HERS REQUIRED VERIFICATION
--------------------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
COMPUTER METHOD SUMMARY Page 1 C-2R
Project Title.......... Plan 7 w/Casita Date..10/04/02 15.33:29
Project Address........ La Cala ******* ---------------------
La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field -Check/ Date
--
Climate Zone........... 15---------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
_____________
MICROPAS6 v6.01 File-21105MG1 Wth-CTZ15S92 Program -FORM C-2R
User#-MP0940 User -Heritage Energy Group Run-
----------------------------------- ---------------------------------------
_
MICROPAS6
ENERGY USE
SUMMARY
=
----------------------------
= Energy Use
Standard
Proposed
-
Compliance =
- (kBtu/sf-yr)
_-----------------------
Design
----------
Design
----------
Margin =
-
= Space
Heating..........
3.98
2.98
----------
1.00 =
= Space
Cooling..........
38.53
35.39
3.14 =
= Water
Heating..........
9.14
9.15
-0.01 =
=
North Total
51.65
47.52
4.13 =
= Space
Heating..........
3.98
3.52
0.46 =
= Space
Cooling..........
38.53
37.68
0.85 =
= Water
Heating..........
9.14
9.15
-0.01 =
=
East Total
51.65
50.35
1.30 =
= Space
Heating..........
3.98
3.32
0.66 =
= Space
Cooling..........
38.53
35.44
3.09 =
- Water
Heating..........
9.14
9.15
-0.01 =
=
South Total
51.65
47.91
3.74 =
= Space
Heating..........
3.98
3.13
0.85 =
- Space
Cooling..........
38.53
38.17
0.36 =
= Water
Heating..........
9.14
9.15
-0.01 =
=
West Total
51.65
50.45
1.20 =
_ *** Building complies
with Computer Performance
GENERAL INFORMATION
Conditioned Floor Area..... 3118 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 3
Conditioned Volume......... 31180 cf
COMPUTER METHOD SUMMARY
Page 2
C-2R
Project
Title..........
Plan 7 w/Casita
Date..10/04/02
15:33:29
Slab -On
-Grade
---------------------------------------------------
Area.........
3118 sf
Glazing
Percentage.........
20.7 %
of floor area
Average
Glazing
U-factor...
0.36 Btu/hr-sf-F
Average
Glazing
SHGC.......
0.34
Average
Ceiling
Height.....
10 ft
BUILDING ZONE
INFORMATION
Floor
-------------------------
# of
Vent Vent
Air
Area
Volume
Dwell Cond- Thermostat
Height Area
Leakage
Zone
--------------
Type (sf)
-----
(cf)
-------
Units itioned Type (ft) (sf)
-----
Credit
1
-------
-----------
----------------------
Residence
1026
10260
0.33 Yes
Setback 2.0 Standard
No
2
Residence
1628
16280
0.52 Yes
Setback 2.0 Standard
No
3
Residence
464
4640
0.15 Yes
Setback 2.0 Standard
No
OPAQUE SURFACES
Area
U-
---------------
Insul Act
Solar
Form 3 Location/
Surface
--------------
(sf)
------
factor
-----
R-val Azm Tilt Gains
-----
Reference Comments
1
--- ----
-----
------------ -------•----------
2
Wall
218
0.065
19 180
90 Yes
None
3
Wall
120
0.065
19 270
90 Yes
None
4
Wall
134
0.065
19 0
90 Yes
None
5
Wall
50
0.065
19 90
90 Yes
None
6
Roof
1033
0.035
30 n/a
0 Yes
None
7
Door
28
0.330
0 0
90 Yes
None
8
Door
17
0.330
0 0
90 No
None
2
12
Wall
170
0.065
19 180
90 Yes
None
13
Wall
494
0.065
19 270
90 Yes
None
14
Wall
333
0.065
19 0
90 Yes
None
15
Wall
571
0.065
19 90
90 Yes
None
16
Wall
144
0.065
19 0
90 No
None
17
Roof
1628
0.035
30 n/a
0 Yes
None
3
18
Roof
464
0.035
30 n/a
0 Yes
None
19
Wall
142
0.065
19 180
90 Yes
None
20
Wall
270
0.065
19 270
90 Yes
None
21
Wall
193
0.065
19 0
90 Yes
None
22
Wall
270
0.065
19 90
90 Yes
None
PERIMETER
LOSSES
Length
----------------
F2 Insul
Solar
Surface (ft)
------------ ------
Factor R-val
---------------
Gains
-----
Location/Comments
1
----------------------
1
SlabEdge
70
0.510 R-0
No
2
9
SlabEdge
195
0.760 R-0
No
11
SlabEdge
16
0.510 R-0
No
3
10
SlabEdge
98
0.760 R-0
No
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29
---------------
Area
Orientation
(sf)
------------------ -
1
FENESTRATION SURFACES
---------------------
Exterior
U- Act Shade
factor SHGC Azm Tilt Type---- Location/Comments
--- --- ----------------------------
1
Door
Back
(S)
64.0
0.350
0.330
180
90
Standard
vinyl
framed
low-e
2
Wind
Back
(S)
39.0
0.350
0.320
180
90
Standard
vinyl
framed
low-e
3
Wind
Back
(S)
39.0
0.350
0.320
180
90
Standard
vinyl
framed
low-e
11
Wind
Front
(N)
36.0
0.350
0.310
0
90
Standard
vinyl
framed
low-e
2
4
Door
Back
(S)
80.0
0.350
0.330
5
Door
Back
(S)
80.0
0.350
0.330
8
Wind
Right
(W)
36.0
0.350
0.310
9
Wind
Right
(W)
50.0
0.350
0.310
10
Wind
Right
(W)
9.9
0.350
0.310
12
Wind
Front
(N)
9.5
0.350
0.310
13
Door
Front
(N)
48.0
0.550
0.650
16
Wind
Left
(E)
25.0
0.350
0.310
17
Wind
Left
(E)
11.4
0.350
0.310
18
Wind
Left
(E)
12.5
0.350
0.310
3
6
Door
Back
(S)
48.0
7
Wind
Back
(S)
30.0
14
Wind
Front
(N)
9.0
15
Wind
Front
(N)
18.0
Surface----
1
1 Door
2 Window
11 Window
2
4 Door
5 Door
12 Window
13 Door
3
6 Door
7 Window
14 Window
15 Window
180 90 Standard vinyl framed low-e
180 90 Standard vinyl framed low-e
270 90 Standard vinyl framed low-e
270 90 Standard vinyl framed low-e
270 90 Standard vinyl framed low-e
0 90 Standard vinyl framed low-e
0 90 Standard Non metal framed clear
90 90 Standard vinyl framed low-e
90 90 Standard vinyl framed low-e
90 90 Standard vinyl framed low-e
0.350
0.330
180
90
Standard
vinyl
framed
low-e
0.350
0.310
180
90
Standard
vinyl
framed
low-e
0.350
0.310
0
90
Standard
vinyl
framed
low-e
0.350
0.310
0
90
Standard
vinyl
framed
low-e
OVERHANGS AND SIDE FINS
---Window--
-----------------------
------Overhang-----
---Left Fin---
---Right
Fin --
Area
Left
Rght
(sf)
-----
Wdth
-----
Hgth
-----
Dpth Hght
---- ----
Ext
----
Ext
----
Ext
----
Dpth
----
Hght
----
Ext
----
Dpth
----
Hght
----
64.0
n/a
8
8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
39.0
n/a
8
8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
36.0
n/a
6
1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
80.0
n/a
8
5
1
n/a
n/a
n/a
n/a.
n/a
n/a
n/a
n/a
80.0
n/a
8
8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
9.5
n/a
6
1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
48.0
n/a
6
1
1
n/a
n/a
n/a
n/a.
n/a
n/a
n/a
n/a
48.0
n/a
6
1
1
n/a
n/a
n/a
n/a
n/a
n/a.
n/a
n/a
30.0
n/a
6
1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
9.0
n/a
6
1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
18.0
n/a
6
1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type
----------------
(sf)
------
1
Standard
Slab
1026
2
Standard
Slab
1628
3
Standard
Slab
464
COMPUTER METHOD SUMMARY
Page 4
C-2R
Project Title.......... Plan 7 w/Casita
--------------
Date..10/04/02 15:33:29
HVAC SYSTEMS
------------
Refrigerant
Tested
ACCA
System
Minimum
Charge and Duct
Duct
Duct
Manual
Duct
Type
-------------
Efficiency
-----------
Airflow Location R-value
--------------------
Leakage
D
Eff
1
-------
----------------
----
Furnace
0.800 AFUE
n/a Attic
R-4.2
Yes
No
0.815
ACSplitTXV
12.00 SEER
Yes Attic
R-4.2
Yes
No
0.703
2
Furnace
0.800 AFUE
n/a Attic
R-4.2
Yes
No
0.815
ACSplitTXV
12.00 SEER
Yes Attic
R-4.2
Yes
No
0.703
3
HPSplit
6.60 HSPF
n/a Attic
R-4.2
Yes
No
0.847
HPSplit
12.00 SEER
No Attic
R-4.2
Yes
No
0.703
DUCT TESTING DETAILS
--------------------
Duct
Measured Supply
Leakage Target
Duct Surface Area
Equipment Type
------------------------
(% fan CFM/CFM25)
------------------
(ft2)
1
-----------------
Furnace
/ ACSplitTXV 6% / 43.1
n/a
2
Furnace
/ ACSplitTXV 6% / 68.4
n/a
3
HPSplit
/ HPSplit
6% / 19.5
n/a
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R-value
---------------------------------------- -------------- ----------------
1 Storage Gas Recirc/TimeTemp 1 0.51 75 R-12
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
This building incorporates Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system (s) .
ndatory Measures require a R-12 or greater external blanket on Gas Storage
ter Heaters with Energy Factors less than 0.58.
HERS REQUIRED VERIFICATION
--------------------------
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
COMPUTER METHOD SUMMARY Page 5 C-2R
Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29
HERS REQUIRED VERIFICATION
--------------------------
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for. Tested Duct Leakage.
This building incorporates either Tested Refrigerant Charge and Airflow (RCA)
or a Thermostatic Expansion Valve (TXV) on the specified air conditioning
system(s). If a cooling system is not installed, then HERS verification
is not necessary for the RCA or TXV.
REMARKS
COMPUTER METHOD SUMMARY
Page 1 C-2R
Project Title..........
Project Address........
Plan 8
Date..09/12/02 11:53:36
La Cala
*******
---------------------
La Quinta
*v6.01*
Documentation Author...
Rudy Sains
*******
Building Permit
Heritage Energy Group
15375 Barranca Pkwy,
Suite F-101
Plan Check / Date
Irvine, CA 92618
Climate Zone.... .....
949-789-7221
15
---------------------
Field Check/ Date
Compliance Method......
MICROPAS6 v6.01 for
2001 Standards by Enercomp, Inc.
I MICROPAS6 v6.01 File-21105M81 Wth-CTZ15S92 Program -FORM C-2R
----------------User#-MP0940 User -Heritage
Energy Group
Run-
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
------------------------
Design
----------
Design
Margin =
= Space
Heating..........
2.74
----------
2.19
---------- -
0.55 =
= Space
Cooling..........
34.86
32.59
2.27 =
= Water
Heating..........
10.09
10.10
-0.01 =
=
North Total
47.69
44.88
-
2.81 =
= Space
Heating..........
2.74
2.79
-0.05 =
= Space
Cooling..........
34.86
34.14
0.72 =
= Water
Heating..........
10.09
10.10
-0.01 =
=
East Total
47.69
47.03
0.66 =
= Space
Heating..........
2.74
2.95
-0.21 =
= Space
Cooling..........
34.86
31.79
3.07 =
= Water
Heating..........
10.09
10.10
-0.01 =
=
South Total
47.69
44.84
2.85 =
= Space
Heating..........
2.74
2.55
0.19 =
= Space
Cooling..........
34.86
34.11
0.75 =
= Water
Heating..........
10.09
10.10
-0.01 =
=
West Total
47.69
46.76
0.93 =
_ *** Building complies
with Computer Performance
GENERAL INFORMATION
Conditioned Floor Area..... 2823 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 2
Conditioned Volume......... 28230 cf
COMPUTER METHOD SUMMARY Page 2 C-2R
Project Title.......... Plan 8-----Date__09/12/02 11:53:36
-------------------------------------------------------
Slab -On -Grade Area......... 2823 sf
Glazing Percentage......... 20.8 % of floor area
Average Glazing U-factor... 0.35 Btu/hr-sf-F
Average Glazing SHGC....... 0.32
Average Ceiling Height..... 10 ft
Floor
Area
Zone Type (sf)
-------------- -----
1
Residence 1361
2
Residence 1462
Surface
1
2
Wall
3
Wall
4
Wall
5
Roof
6
Door
7
Door
2
10
Wall
11
Wall
12
Wall
13
Wall
14
Wall
15
Roof
BUILDING ZONE INFORMATION
-------------------------
# of Vent Vent Air
Volume Dwell Cond- Thermostat Height Area Leakage
(cf) Units itioned Type (ft) (sf) Credit
------- ----- ----------------- ----- -------- ---------
13610 0.48 Yes Setback 2.0 Standard No
14620 0.52 Yes Setback 2.0 Standard No
OPAQUE
SURFACES
Area
U-
---------------
Insul
Act
Solar
Form 3 Location/
(sf)
------
factor
-----
R-val
-----
Azm
---
Tilt
----
Gains
-----
Reference Comments
------------ ----------------
195
0.065
19
180
90
Yes
None
346
0.065
19
270
90
Yes
None
242
0.065
19
0
90
Yes
None
1316
0.031
30
n/a
0
Yes
None
27
0.330
0
0
90
Yes
None
17
0.330
0
0
90
No
None
206
0.065
19
180
90
Yes
None
166
0.065
19
270
90
Yes
None
387
0.065
19
90
90
Yes
None
270
0.065
19
0
90
No
None
153
0.065
19
90
90
No
None
1462
0.035
30
n/a
0
Yes
None
Length
Surface (ft)
------------ ------
1
1 S1abEdge 114
2
8 S1abEdge 97
9 S1abEdge 47
PERIMETER LOSSES
----------------
F2 Insul Solar
Factor R-val Gains Location/Comments
--------------- ---------------------------
0.760 R-0 No
0.760 R-0 No
0.510 R-0 No
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type
1 ---- ----- --- ------------
Location/Comments
------------------------
1
2
Door
Wind
Back
(S)
128.0
0.350
0.330
180
90
Standard
Vinyl
framed
low-e
Back
(S)
15.0
0.350
0.320
180
90
Standard
vinyl
framed
low-e
3
Door
Back
(S)
72.0
0.350
0.330
180
90
Standard
Vinyl
framed
low-e
6
Wind
Right
(W)
20.0
0.350
0.310
270
90
Standard
vinyl
framed
low-e
7
Wind
Right
(W)
24.0
0.350
0.310
270
90
Standard
vinyl
framed
low-e
9
Wind
Front
(N)
128.0
0.350
0.310
0
90
Standard
vinyl
framed
low-e
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... Plan 8 Date..09/12/02 11:53:36
FENESTRATION SURFACES
Exterior
Area
U-
Act
Shade
Orientation
-(sf)
factor SHGC
--- -----
Azm
Tilt
Type
Location/Comments
10
Wind
Front
(N)
10.5
0.350
0.310
---
0
----
90
--------
Standard
------------------------
vinyl
framed
low-e
2
4
Door
Back
(S)
64.0
0.350
0.330
180
90
Standard
Vinyl
framed
low-e
5
Wind
Back
(S)
20.0
0.350
0.310
180
90
Standard
vinyl
framed
low-e
8
Door
Right
(W)
64.0
0.350
0.330
270
90
Standard
Vinyl
framed
low-e
11
Wind
Left
(E)
30.0
0.350
0.310
90
90
Standard
vinyl
framed
low-e
12
Wind
Left
(E)
12.9
0.350
0.310
90
90
Standard
vinyl
framed
low-e
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin ---
Area Left Rght
---Right Fin --
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
1
1
Door
128.0
n/a
2
Window
15.0
n/a
3
Door
72.0
n/a
6
Window
20.0
n/a
7
Window
24.0
n/a
9
Window
128.0
n/a
10
Window
10.5
n/a
2
5
Window
20.0
n/a
8
Door
64.0
n/a
11
Window
30.0
n/a
System
Type
--- ------
1
Furnace
ACSplit
2
Furnace
ACSplit
8 10 1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
6 1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
6 1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
8 8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
8 8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
8 8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
6 1
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5 5
0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
8 8
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5 1
2
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type
----------------
(sf)
------
1
Standard
Slab
1361
2
Standard
Slab
1462
HVAC SYSTEMS
------------
Refrigerant
Tested
ACCA
Minimum
Charge and Duct
Duct
Duct
Manual
Duct
Efficiency
-------
Airflow Location
--------------------
R-value
-------
Leakage
---------
D
--------
Eff
----
0.800 AFUE
n/a Attic
R-4.2
Yes
No
0.815
12.00 SEER
No Attic
R-4.2
Yes
No
0.703
0.800 AFUE
n/a Attic
R-4.2
Yes
No
0.815
12.00 SEER
No Attic
R-4.2
Yes
No
0.703
COMPUTER METHOD SUMMARY Page 4 C-2R
Project Title.......... Plan 8 Date..09/12/02 11:53:36
--------------
Equipment Type
1
Furnace / ACSplit
2
Furnace / ACSplit
DUCT TESTING DETAILS
--------------------
Duct
Leakage Target
(% fan CFM/CFM25)
------------------
6% / 57.2
6% / 61.4
Measured Supply
Duct Surface Area
(ft2)
-----------------
WATER HEATING SYSTEMS
---------------------
Number
in
Tank Type Heater Type Distribution Type System
------------ ----------- ------------------- ------
1 Storage Gas Recirc/TimeTemp 1
n/a
n/a
Tank
External
Energy Size
Insulation
Factor (gal)
--------
R-value
------
0.51 75
----------
R-12
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
This building incorporates Tested Duct Leakage.
Mandatory Measures require a R-12 or greater external blanket on Gas Storage
Water Heaters with Energy Factors less than 0.58.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy .rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
,for Tested Duct Leakage.
REMARKS
COMPUTER METHOD SUMMARY Page 1 C-2R
------------------------------------------------------------
Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42
Project Address........ La Cala ******* ---------------------
La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field Check Date
Climate Zone. ...... 15 -------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File-21105MH1 Wth-CTZ15S92 Program -FORM C-2R
----------------User#_MP0940 User -Heritage Energy Group Run-
=
_
MICROPAS6
ENERGY USE
------------------
SUMMARY
=
----------------------------
= Energy Use
Standard
Proposed
-
Compliance =
_ (kBtu/sf-yr)
_---------------------------------
Design
Design
Margin =
= Space
Heating..........
3.51
----------
2.60
---------- -
0.91 =
= Space
Cooling..........
36.50
34.75
1.75 =
= Water
Heating..........
8.88
8.89
-0.01 =
=
North Total
48.89
46.24
2.65 =
= Space
Heating..........
3.51
3.31
0.20 =
= Space
Cooling..........
36.50
36.67
-0.17 =
= Water
Heating..........
8.88
8.89
-0.01 =
=
East Total
48.89
48.87
0.02 =
= Space
Heating..........
3.51
3.49
0.02 =
= Space
Cooling..........
36.50
33.48
3.02 =
= Water
Heating..........
8.88
8.89
-0.01 =
=
South Total
48.89
45.86
3.03 =
= Space
Heating..........
3.51
3.05
0.46 =
= Space
Cooling..........
36.50
36.65
-0.15 =
= Water
Heating..........
8.88
8.89
-0.01 =
=
West Total
48.89
48.59
0.30 =
*** Building complies with Computer Performance ***
GENERAL INFORMATION
Conditioned Floor Area..... 3208 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 3
Conditioned Volume......... 32090 cf
COMPUTER METHOD SUMMARY Page 2 C-2R
Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42
-----------------------------------------------
Slab -On -Grade Area......... 3208 sf
Glazing Percentage......... 20.4 % of floor area
Average Glazing U-factor... 0.36 Btu/hr-sf-F
Average Glazing SHGC....... 0.33
Average Ceiling Height..... 10 ft
BUILDING ZONE INFORMATION
-------------------------
Floor # of Vent Vent Air
Area Volume Dwell Cond- Thermostat Height Area Leakage
Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit
-------------- ------------ ----------------------- ----------------------
1
2 Residence 1361 13620 0.43 Yes Setback 2.0 Standard No
3 Residence 1462 14620 0.45 Yes Setback 2.0 Standard No
Residence 385 3850 0.12 Yes Setback 2.0 Standard No
OPAQUE SURFACES
---------------
Area U- Insul Act Solar Form 3 Location/
Surface (sf) factor R-val Azm Tilt Gains Reference Comments
-------------- ------ ----- ----- --- ---- ----------------- ----------------
1
2 Wall 195 0.065 19 180 90 Yes None exterior:
3 Wall 346 0.065 19 270 90 Yes None
4 Wall 242 0.065 19 0 90 Yes None
5 Roof 1361 0.031 30 n/a 0 Yes None Attic:
6 Door 27 0.330 0 0 90 Yes None frt door
2 7 Door 17 0.330 0 0 90 No None garage door
11 Wall. 206 0.065 19 180 90 Yes None Exterior:
12 Wall 166 0.065 19 270 90 Yes None
13 Wall 387 0.065 19 90 90 Yes None
14 Wall 270 0.065 19 0 90 No None Garage/house
15 Wall 153 0.065 19 90 90 No None Garage/house
16 Roof 1462 0.031 30 n/a 0 Yes None Attic:
3
17 Roof 385 0.035 30 n/a 0 Yes None Attic:
18 Wall 191 0.065 19 180 90 Yes None
19 Wall 180 0.065 19 270 90 Yes None
20 Wall 223 0.065 19 0 90 Yes None
21 Wall 180 0.065 19 90 90 Yes None
PERIMETER LOSSES
----------------
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1
1 SlabEdge 114 0.760 R-0 No to outside
2
8 SlabEdge 97 0.760 R-0 No
10 SlabEdge 47 0.510 R-0 No
3
9 SlabEdge 80 0.760 R-0 No
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42
---------------
FENESTRATION SURFACES
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
1
1 Door Back (S) 128.0 0.350 0.330 180 90 Standard vinyl framed low-e
2 Wind Back (S) 15.0 0.350 0.320 180 90 Standard vinyl framed low-e
3 Door Back (S) 72.0 0.350 0.330 180 90 Standard vinyl framed low-e
6 Wind Right (W) 20.0 0.350 0.310 270 90 Standard vinyl framed low-e
7 Wind Right (W) 24.0 0.350 0.310 270 90 Standard vinyl framed low-e
9 Wind Front (N) 128.0 0.350 0.310 0 90 Standard vinyl framed low-e
10 Wind Front (N) 10.5 0.350 0.310 0 90 Standard vinyl framed low-e
2
4 Door Back (S) 64.0 0.350 0.330 180 90 Standard vinyl framed low-e
5 Wind Back (S) 20.0 0.350 0.310 180 90 Standard vinyl framed low-e
8 Door Right (W) 64.0 0.350 0.330 270 90 Standard vinyl framed low-e
11 Wind Left (E) 30.0 0.350 0.310 90 90 Standard vinyl framed low-e
12 Wind Left (E) 12.9 0.350 0.310 90 90 Standard vinyl framed low-e
3
13 Wind Back (S) 25.0 0.350 0.310 180 90 Standard vinyl framed low-e
14 Door Back (S) 24.0 0.550 0.650 180 90 Standard non metal dual clear
15 Wind Front (N) 13.5 0.350 0.310 0 90 Standard vinyl framed low-e
16 Wind Front (N) 3.8 0.350 0.320 0 90 Standard vinyl framed low-e
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
1
1 Door 128.0 n/a 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 15.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a
3 Door 72.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a
6 Window 20.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a
7 Window 24.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a
9 Window 128.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a
10 Window 10.5 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a
2
5 Window 20.0 n/a 5 5 0 n/a n/a n/a n/a n/a n/a n/a n/a
8 Door 64.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a
11 Window 30.0 n/a 5 1 2 n/a n/a n/a n/a n/a n/a n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 1361
2
Standard Slab 1462
3
Standard Slab 385
COMPUTER METHOD SUMMARY Page 4 C-2R
Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42
System
Minimum
Type
-------------
Efficiency
-----------
1
Furnace
0.800
AFUE
ACSplit
12.00
SEER
2
Furnace
0.800
AFUE
ACSplit
12.00
SEER
3
HPSplit
6.60
HSPF
HPSplit
12.00
SEER
Equipment Type
1
Furnace / ACSplit
2
Furnace / ACSplit
3
HPSplit / HPSplit
HVAC SYSTEMS
------------
Refrigerant
Tested
ACCA
Charge and Duct
Duct
Duct
Manual
Duct
Airflow Location
--------------------
R-value
-------
Leakage
---------
D
--------
Eff
----
n/a Attic
R-4.2
Yes
No
0.815
No Attic
R-4.2
Yes
No
0.703
n/a Attic
R-4.2
Yes
No
0.815
No Attic
R-4.2
Yes
No
0.703
n/a Attic
R-4.2
Yes
No
0.847
No Attic
R-4.2
Yes
No
0.703
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
(% fan CFM/CFM25) (ft2)
-----------------------------------
6%
/
57.2
n/a
6%
/
61.4
n/a
6%
/
16.2
n/a
WATER HEATING SYSTEMS
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R-value
------------------------------------------ -------------- ----------------
1 Storage Gas Recirc/TimeTemp 1 0.51 75 R-12
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
This building incorporates Tested Duct Leakage.
'Mandatory Measures require a R-12 or greater external blanket on Gas Storage
Water Heaters with Energy Factors less than 0.58.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
COMPUTER METHOD SUMMARY Page 5 C-2R
Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42
HERS REQUIRED VERIFICATION
--------------------------
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
REMARKS
COMPUTER METHOD SUMMARY Page 1 C-2R
Project Title.......... Plan 9 Date..09/12/02 11.56.54
Project Address........ La Cala ******* ---------------------
La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field Check/ Date
Climate Zone. 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
--- MICROPAS6 v6.01 File-21105M91 Wth-CTZ15S92 Program -FORM C-2R
----User#-MP0940 User -Heritage Energy Group Run-
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
----------
Design
----------
Margin =
= Space
Heating..........
2.81
2.35
---------- -
0.46 =
= Space
Cooling..........
35.31
33.81
1.50 =
= Water
Heating..........
8.79
8.80
-0.01 =
=
North Total
46.91
44.96
1.95 =
= Space
Heating..........
2.81
2.62
0.19 =
= Space
Cooling..........
35.31
33.35
1.96 =
= Water
Heating..........
8.79
8.80
-0.01 =
=
East Total
46.91
44.77
2.14 =
= Space
Heating..........
2.81
3.00
-0.19 =
= Space
Cooling..........
35.31
33.40
1.91 =
= Water
Heating..........
8.79
8.80
-0.01 =
=
South Total
46.91
45.20
1.71 =
= Space
Heating..........
2.81
2.54
0.27 =
= Space
Cooling..........
35.31
33.37
1.94 =
= Water
Heating..........
8.79
8.80
-0.01 =
=
West Total
46.91
44.71
2.20 =
_ *** Building complies
with Computer Performance
***
GENERAL INFORMATION
Conditioned Floor Area..... 3240 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 2
Conditioned Volume......... 32400 cf
COMPUTER METHOD SUMMARY Page 2 C-2R
Project Title.......... Plan 9---------Date..09/12/02 11:56:54
------------------------------------------------------
Slab -On -Grade Area......... 3240 sf
Glazing Percentage......... 16.5 % of floor area
Average Glazing U-factor... 0.36 Btu/hr-sf-F
Average Glazing SHGC....... 0.34
Average Ceiling Height..... 10 ft
BUILDING ZONE INFORMATION
Floor
# of
Vent
Vent Air
Area
Volume
Dwell Cond-
Thermostat
Height Area Leakage
Zone
Type
(sf)
(cf)
---
Units itioned
------------
Type (ft)
(sf) Credit
1
-----------
-----
-----------------
Residence
1384
13840
0.43 Yes
Setback 2.0
Standard No
2
Residence
1856
18560
0.57 Yes
Setback 2.0
Standard No
OPAQUE SURFACES
Area
U-
---------------
Insul Act
Solar
Form 3
Location/
Surface
(sf)
factor
----
R-val Azm Tilt
----- --- ----
Gains
Reference
Comments
1
-----
------------
----------------
2
Wall
170
0.065
19 180
90
Yes
None
exterior:
3
Wall
358
0.065
19 270
90
Yes
None
4
Wall
150
0.065
19 0
90
Yes
None
5
Wall
687
0.065
19 90
90
Yes
None
6
Roof
1384
0.035
30 n/a
0
Yes
None
Attic:
7
Door
27
0.330
0 0
90
Yes
None
frt door
8
Door
17
0.330
0 0
90
No
None
garage door
11
Wall
260
0.065
19 180
90
Yes
None
Exterior:
12
Wall
349
0.065
19 270
90
Yes
None
13
Wall
361
0.065
19 0
90
Yes
None
14
Wall
274
0.065
19 90
90
Yes
None
15
Wall
225
0.065
19 0
90
No
None
Garage/house
16
Roof
1856
0.035
30 n/a
0
Yes
None
Attic:
PERIMETER
LOSSES
Length
----------------
F2 Insul
Solar
Surface
-(ft)- Factor
R-val
Gains
Location/Comments
1
1 SlabEdge
2
9 SlabEdge
10 SlabEdge
116
0.760
R-0
136
0.760
R-0
25
0.510
R-0
No to outside
No
No
FENESTRATION SURFACES
----------------------
Exterior
Area U- Act Shade
Orientation -(sf) factor SHGC Azm Tilt Type Location/Comments
1
Door
Back
(S)
80.0
0.350
0.330
180
90
Standard
vinyl
framed
low-e
2
Wind
Back
(S)
78.0
0.350
0.320
180
90
Standard
vinyl
framed
low-e
3
Door
Back
(S)
52.0
0.350
0.330
180
90
Standard
vinyl
framed
low-e
5
Door
Right
(W)
48.0
0.350
0.330
270
90
Standard
vinyl
framed
low-e
6
Door
Right
(W)
24.0
0.550
0.650
270
90
Standard
non metal dual clear
COMPUTER METHOD SUMMARY I
Page 3 C-2R
Project Title.......... Plan 9 Date..09/12/02 11:56:54
FENESTRATION SURFACES
Exterior
Orientation
Area
(sf)
--
U-
factor SHGC
-----
Act
Azm
Tilt
Shade
Type
Location/Comments
10
11
Wind
Wind
Left
Left
(E)
(E)
36.0
6.7
0.350
0.350
-----
0.310
---
90
----
90
- -
--------
Standard
------------------
Vinyl
framed
low-e
2
0.320
90
90
Standard
vinyl
framed
low-e
4
7
Door
Wind
Back
Right
(S)
(W)
80.0
24.0
0.350
0.330
180
90
Standard
vinyl
framed
low-e
8
Wind
Right
(W)
6.7
0.350
0.350
0.310
270
90
Standard
Vinyl
framed
low-e
9
Wind
Front
(N)
24.0
0.350
0.320
0.310
270
0
90
90
Standard
Standard
vinyl
Vinyl
framed
framed
low-e
low-e
12
13
Wind
Wind
Left
Left
(E)
(E)
72.0
4.0
0.350
0.350
0.310
90
90
Standard
Vinyl
framed
low-e
0.310
90
90
Standard
Vinyl
framed
low-e
Area
Surface
(sf)
----------- -
1
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Left Rght
Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
1 Door
2 Window
80.0 n/a
78.0 n/a
8
6
12 1
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
3 Door
52.0 n/a
6
1
1.5 1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5 Door
6 Door
48.0 n/a
24.0 n/a
8
6
10 1
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
10 Window
36.0 n/a
8
1
10 1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
11 Window
2
6.7 n/a
6
1.5 1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4 Door
7 Window
80.0 n/a
24.0 n/a
8
6
9 1
1.5
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
8 Window
6.7 n/a
1.6
1
1.5 1.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
12 Window
72.0 n/a
6
1.5 1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
SLAB SURFACES
-------------
Area
Slab Type
----------------
(sf)
------
1
Standard
Slab
1384
2
Standard
Slab
1856
HVAC SYSTEMS
System
Minimum
------------
Refrigerant
Charge and Duct
Duct
Tested
Duct
ACCA
Manual
Duct
Type
----------
Efficiency
-----------
Airflow Location
-------
R-value
Leakage
D
Eff
-------------
-------
---------
--------
----
Furnace
ACSplit
0.800 AFUE
12.00 SEER
n/a Attic
No Attic
R-4.2
Yes
No
0.815
2
R-4.2
Yes
No
0.703
(Furnace
ACSplit
0.800 AFUE
12.00
n/a Attic
R-4.2
Yes
No
0.815
SEER
No Attic
R-4.2
Yes
No
0.703
COMPUTER METHOD SUMMARY Page 4 C-2R
Project Title.......... Plan 9 Date..09/12/02 11:56:54
Equipment Type
1
Furnace / ACSplit
2
Furnace / ACSplit
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
(% fan CFM/CFM25) (ft2)
-----------------------------------
6% / 58.1
6% / 78.0
WATER HEATING SYSTEMS
n/ a
n/ a
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R-value
---------------------- ------ -- ---- ------ ------
1 Storage Gas Recirc TimeTemp 1 0.51 75 R-12
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This is a multiple orientation building with no orientation restrictions.
This printout is for the front facing North.
This building incorporates Tested Duct Leakage.
Mandatory Measures require a R-12 or greater external blanket on Gas Storage
Water Heaters with Energy Factors less than 0.58.
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
(compliance calculations could be redone without duct testing.
IIf ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
REMARKS
COMPUTER METHOD SUMMARY Page 1 C-2R
Project Title.......... Plan 9 w/Casita Date..09/12/02 12:14:08
Project Address........ La Cala ******* ---------------------
La Quinta *v6.01*
Documentation Author... Sam Maimone ******* Building Permit
Heritage Energy Group
15375 Barranca Pkwy, Suite F-101 Plan Check / Date
Irvine, CA 92618
949-789-7221 Field Check/ Date
Climate Zone. .. ..... 15 ---------------------
Compliance Method ...... -MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File-21105M11 Wth-CTZ15S92 Program -FORM C-2R
------User#-MP0940 User -Heritage Energy Group Run -
MICROPAS6 ENERGY USE SUMMARY
- Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
---------
Design
Margin =
= Space
Heating..........
3.55
----------
2.67
----------
0.88 =
= Space
Cooling..........
36.31
35.53
0.78 =
= Water
Heating..........
7.47
7.47
0.00 =
=
North Total
47.33
45.67
1.66 =
= Space
Heating..........
3.55
3.20
0.35 =
= Space
Cooling..........
36.31
35.20
1.11 =
= Water
Heating..........
7.47
7.47
0.00 =
=
East Total
47.33
45.87
1.46 =
= Space
Heating..........
3.55
3.55
0.00 =
= Space
Cooling..........
36.31
34.69
1.62 =
= Water
Heating..........
7.47
7.47
0.00 =
South Total
47.33
45.71
1.62 =
= Space
Heating..........
3.55
2.88
0.67 =
= Space
Cooling..........
36.31
35.42
0.89 =
= Water
Heating..........
7.47
7.47
0.00 =
=
West Total
47.33
45.77
1.56 =
_ ***
Building complies
with Computer Performance
***
GENERAL INFORMATION
Conditioned Floor Area..... 3816 sf
Building Type .............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Cardinal - N,E,S,W
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 3
Conditioned Volume......... 38160 cf
COMPUTER METHOD SUMMARY
Page 2
Project
Title.......... Plan 9 w/Casita
------------------------------------------
Date..09/12/02
C-2R
12:14:08
Slab -On -Grade
Area.........
3816
____________________
sf
Glazing
Percentage.........
17.3
% of floor area
Average
Glazing U-factor...
0.36
Btu/hr-sf-F
Average
Glazing SHGC.......
0.35
Average
Ceiling Height.....
10 ft
BUILDING ZONE
INFORMATION
Floor
-------------------------
# of
Vent Vent
Air
Area
Zone Type (sf)
Volume Dwell Cond- Thermostat Height Area
Units itioned
Leakage
-(cf)--
------------
Type
(ft) (sf)
Credit
1
-----------
----------------------
Residence 1384
13840
0.36 Yes
Setback 2.0 Standard
No
2
Residence 1856
18560
0.49 Yes
Setback 2.0 Standard
No
3
Residence 576
5760
0.15 Yes
Setback 2.0 Standard
No
OPAQUE SURFACES
Surface
Area
(sf)
U-
factor
---------------
Insul Act Solar Form 3 Location/
R-val Azm Tilt Gains Reference
----
-----
Comments
1
------------ ----------------
2 Wall
170
0.065
19 180
90 Yes
None
3 Wall
358
0.065
19 270
90 Yes
None
4 Wall
150
0.065
19 0
90 Yes
None
5 Wall
687
0.065
19 90
90 Yes
None
6 Roof
1384
0.035
30 n/a
0 Yes
None
7 Door
27
0.330
0 0
90 Yes
None
8 Door
'
17
0.330
0 0
90 No
None
2
13 Wall
114
260
0.065
19 180
90 Yes
None
Wall
353
0.065
19 270
90 Yes
None
115 Wall
361
0.065
19 0
90 Yes
None
16 Wall
274
0.065
19 90
90 Yes
None
17 Wall
225
0.065
19 0
90 No
None
18 Roof
1856
0.035
30 n/a
0 Yes
None
3
19 Roof
576
0.035
30 n/a
0 Yes
None
20 Wall
229
0.065
19 180
90 Yes
None
21 Wall
206
0.065
19 270
90 Yes
None
22 Wall
115
0.065
19 0
90 Yes
None
23 Wall
170
0.065
19 90
90 Yes
None
PERIMETER
LOSSES
Length
----------------
F2 Insul
Solar
Surface -(ft) Factor R-val
---------------
Gains
Location/Comments
1
-----
----------------------
1
SlabEdge 116
0.760 R-0
No
2
9
SlabEdge 136
0.760 R-0
No
11
SlabEdge
25
0.510 R-0
No
12
SlabEdge
25
0.510 R-0
No
3
10
SlabEdge
86
0.760 R-0
No
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... Plan 9 w/Casita Date..09 12 02 12:14:08
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation -(sf) factor SHGC Azm Tilt Type Location/Comments
----- ----- --- ------------ ------------------------
1
1 Door Back (S) 80.0 0.350 0.330 180 90 Standard vinyl framed low-e
2 Wind Back (S) 78.0 0.350 0.320 180 90 Standard vinyl framed low-e
3 Door Back (S) 52.0 0.350 0.330 180 90 Standard vinyl framed low-e
5 Door Right (W) 48.0 0.350 0.330 270 90 Standard vinyl framed low-e
6 Door Right (W) 24.0 0.550 0.650 270 90 Standard non metal dual clear
9 Wind Left (E) 36.0 0.350 0.310 90 90 Standard vinyl framed low-e
10 Wind Left (E) 6.7 0.350 0.320 90 90 Standard vinyl framed low-e
2
J4 Door Back (S) 80.0 0.350 0.330 180 90 Standard vinyl framed low-e
7 Wind Right (W) 26.8 0.350 0.310 270 90 Standard vinyl framed low-e
8 Wind Front (N) 24.0 0.350 0.310 0 90 Standard vinyl framed low-e
11 Wind Left (E) 72.0 0.350 0.310 90 90 Standard vinyl framed low-e
12 Wind Left (E) 4.0 0.350 0.310 90 90 Standard vinyl framed low-e
3
13 Wind Back (S) 45.0 0.350 0.310 180 90 Standard vinyl framed low-e
14 Door Back (S) 56.0 0.350 0.330 180 90 Standard vinyl framed low-e
15 Door Right (W) 24.0 0.550 0.650 270 90 Standard non metal dual clear
16 Wind Front (N) 5.0 0.350 0.310 0 90 Standard vinyl framed low-e
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
Area Left Rght
.surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
1 Door 80.0 n/a 8 12 1 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 78.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
3 Door 52.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
5 Door 48.0 n/a 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a
6 Door 24.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
9 Window 36.0 n/a 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a
.0 Window 6.7 n/a 1.5 1.5 1..0 n/a n/a n/a n/a n/a n/a n/a n/a
4 Door 80.0 n/a 8 9 1 n/a n/a n/a n/a n/a n/a n/a n/a
7 Window 26.8 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
8 Window 24.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
'_1 Window 72.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
1.3 Window 45.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
4 Door 56.0 n/a 8 4 1 n/a n/a n/a n/a n/a n/a n/a n/a
5 Door 24.0 n/a 8 4 1 n/a n/a n/a n/a n/a n/a n/a n/a
6 Window 5.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
1
Standard Slab 1384
2
Standard Slab 1856
3
COMPUTER METHOD SUMMARY Page 4 C-2R
Project Title.......... Plan 9 w/Casita Date..09 12 02 12.14:08
System
Type
-------------
Furnace
ACSplit
2
Furnace
ACSplit
3
HPSplit
HPSplit
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
Standard Slab 576
HVAC SYSTEMS
------------
Refrigerant
Tested
ACCA
Minimum
Charge and Duct
Duct
Duct
Manual
Duct
Efficiency
-----------
Airflow
-------
Location
-------------
R-value
-------
Leakage
---------
D
--------
Eff
----
0.800
AFUE
n/a
Attic
R-4.2
Yes
No
0.815
12.00
SEER
No
Attic
R-4.2
Yes
No
0.703
0.800
AFUE
n/a
Attic
R-4.2
Yes
No
0.815
12.00
SEER
No
Attic
R-4.2
Yes
No
0.703
6.60
HSPF
n/a
Attic
R-4.2
Yes
No
0.847
12.00
SEER
No
Attic
R-4.2
Yes
No
0.703
Equipment Type
1
2 Furnace / ACSplit
Furnace / ACSplit
3
HPSplit / HPSplit
Tank Type Heater Type
-----------------------
1 Storage Gas
DUCT TESTING DETAILS
--------------------
Duct Measured Supply
Leakage Target Duct Surface Area
(% fan CFM/CFM25) (ft2)
-----------------------------------
6% / 58.1
6% / 78.0
6% / 24.2
WATER HEATING SYSTEMS
---------------------
Number
in
Distribution Type System
------------------- ------
Recirc/TimeTemp 1
n/a
n/a
n/a
Tank
External
Energy Size
Insulation
Factor (gal)
-------- ------
R-value
0.51 75
----------
R-12
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
Phis is a multiple orientation building with no orientation restrictions.
Phis printout is for the front facing North.
Phis building incorporates Tested Duct Leakage.
4andatory Measures require a R-12 or greater external blanket on Gas Storage
4ater Heaters with Energy Factors less than 0.58.
COMPUTER METHOD SUMMARY Page 5 C-2R
Project Title.......... Plan 9 w/Casita Date..09/12/02 12:14:08
HERS REQUIRED VERIFICATION
*** Items in this section require field testing and/or ***
*** verification by a certified home energy rater under ***
*** the supervision of a CEC-approved HERS provider using ***
*** CEC approved testing and/or verification methods and ***
*** must be reported on the CF-6R installation certificate. ***
This building incorporates Tested Duct Leakage. Target CFM leakage
values measured at 25 pascals are shown in DUCT TESTING DETAILS above
or may be calculated as documented on the CF-6R. If the measured CFM
is above the target, then corrective action must be taken to reduce
the duct leakage and then must be retested. Alternatively, the
compliance calculations could be redone without duct testing.
If ducts are not installed, then HERS verification is not necessary
for Tested Duct Leakage.
REMARKS