Loading...
HomeMy WebLinkAboutPGA West Legends - TR 28838 BTCP0009-020 (Plans 8-9) Title 24 - RevisionsA r THE LEGENDS AT PGA WEST La Cala La Quinta CLIMATE ZONE # 15 Revised: Plan 7: UFAR: f a10a $, PLP44 `1 Western Pacific Housing South Coast Architects Ttfis vfLuq- To toot EtAm4y StAADAeDs -p���C.5 Au- '?2V100s%.Y A(?eo\rr-D CN-CS HERITAGE ENERGY GROUP October 4, 2002 Title 24 Energy Calculations (949) 789-7221 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATEAqBY CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF-1R Project Title .......... The legends at PGA West Date..10/04/02 15:33:29 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Name.... Sam Maimone Company. Wes n Paci Housing Company. Heritage Energy Group Address. 16940 Von r n 0200 Address. 15375 Barranca Pkwy, Suite F-101 Iry n CA 06 Irvine, CA 92618 Phone... 9 42-619 Phone... 949-789-7221 License. _ o 1�—Sig d.. to Signed. (date) (da- e) EN,F-ORCKNIT AGENCY Name .... elll(9 L A Id Title... Agency.. Phone... Signed.. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R -------------------------------------------------------------------------------- --------- -------------------------------------------------------- Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29 Project Address........ La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. ..... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------------------------------- MICROPAS6 v6.01 File-21105MG1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0940 User -Heritage Energy Group Run------------------------------------------------------------------------- - GENERAL INFORMATION Conditioned Floor Area..... 3118 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 20.7 % of floor area Average Glazing U-factor... 0.36 Btu/hr-sf-F Average Glazing SHGC....... 0.34 Average Ceiling Height..... 10 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R-value R-value R-value U-factor Location/Comments ------------------------------------------------------------------------- SlabEdge Wall Roof Door SlabEdge None R-0 R-n/a F2=0.510 Wood R-19 R-n/a R-19 0.065 Wood R-30 R-n/a R-30 0.035 Wood R-0 R-n/a R-0 0.330 None R-0 R-n/a F2=0.760 FENESTRATION ------------ Over- Area U- Exterior hang/ Orientation (sf) Factor SHGC Shading Fins Location/Comments ---------------- Door Back (S) ----- 272.0 ------ 0.350 ------ 0.330 -------- ----- Standard Yes -------------------------- vinyl framed low-e Wind Back (S) 39.0 0.350 0.320 Standard Yes vinyl framed low-e Wind Back (S) 39.0 0.350 0.320 Standard None vinyl framed low-e Wind Back (S) 30.0 0.350 0.310 Standard Yes vinyl framed low-e Wind Right (W) 95.9 0.350 0.310 Standard None vinyl framed low-e Wind Front (N) 72.5 0.350 0.310 Standard Yes vinyl framed low-e Door Front (N) 48.0 0.550 0.650 Standard Yes Non metal framed clear Wind Left (E) 48.9 0.350 0.310 Standard None vinyl framed low-e SLAB SURFACES ------------- Area Slab ---------------- Type (sf) ------ Standard Slab 1026 Standard Slab 1628 Standard Slab 464 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29 --------------- HVAC SYSTEMS Refrigerant Equipment Minimum Charge and Duct Duct Type Efficiency Airflow Location R-value ------------------------------------------------- Tested ACCA Duct Manual Thermostat Leakage D Type ------- ------ ---------- Furnace 0.800 AFUE n/a Attic R-4.2 Yes No Setback ACSplitTXV 12.00 SEER Yes Attic R-4.2 Yes No Setback HPSplit 6.60 HSPF n/a Attic R-4.2 Yes No Setback HPSplit 12.00 SEER No Attic R-4.2 Yes No Setback Living: Minimum Heating Load: 13,772 Btuh Cooling Load: 15,035(Sensible),18,042(Total) Beds serv.: Minimum Heating Load: 28,431 Btuh Cooling Load: 26,475(Sensible), 31,770(Total) Casita: Minimum Heating Load: 10,323 Btuh Cooling Load: 9,356(Sensible),11,228(Total) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. That individual is required to provide Form CF-6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF-6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the compliance documentation. DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) ----------------- ------------------------------------------ Furnace / ACSplitTXV 6% / 43.1 n/a Furnace / ACSplitTXV 6% / 68.4 n/a HPSplit / HPSplit 6% / 19.5 n/a WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value -- ---------------------------------------- -------------- ------ ---------- Storage Gas Recirc/TimeTemp 1 0.51 75 R-12 American Water Heater G52-75T75-4NV (or equal) *All piping used to recirculate hot water must be insulated with R-4 insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. A timer must be permanently installed to regulate pump operation. Timer setting must permit the pump to be cycled for at least eight hours per day. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------ This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system (s) . Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29 --------------- HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R --------------- Project Title.......... Plan 8 /Plan 8 w/casita Date..09/12/02 11:53:36 Project Address........ La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date ClimateZone. ..... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. -------------------------------------------------------------- MICROPAS6 v6.01 File-21105M81 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0940 User -Heritage Energy Group Run- ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 2823 sf / 3308 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 20.8 % of floor area Average Glazing U-factor... 0.35 Btu/hr-sf-F Average Glazing SHGC....... 0.32 Average Ceiling Height..... 10 ft BUILDING SHELL INSULATION ------------------------- Component Frame Cavity Sheathing Total Assembly Type Type R-value R-value R-value U-factor Location/Comments ------------------------------------------------- ------------------------ S1abEdge None R-0 R-n/a F2=0.760 Wall Wood R-19 R-n/a R-19 0.065 Roof Wood R-30 R-n/a R-30 0.031 Door Wood R-0 R-n/a R-0 0.330 FENESTRATION ------------ Over- Area U- Exterior hang/ Orientation (sf) Factor SHGC Shading Fins Location/Comments ---------------- ----- ------ -------------- ----- -------------------------- Door Back (S) 200.0 0.350 0.330 Standard Yes Vinyl framed low-e Wind Back (S) 15.0 0.350 0.320 Standard Yes vinyl framed low-e Door Back (S) 64.0 0.350 0.330 Standard None Vinyl framed low-e Wind Back (S) 20.0 0.350 0.310 Standard Yes vinyl framed low-e Wind Right (W) 44.0 0.350 0.310 Standard Yes vinyl framed low-e Door Right (W) 64.0 0.350 0.330 Standard Yes Vinyl framed low-e Wind Front (N) 138.5 0.350 0.310 Standard Yes vinyl framed low-e Wind Left (E) 30.0 0.350 0.310 Standard Yes vinyl framed low-e Wind Left (E) 12.9 0.350 0.310 Standard None vinyl framed low-e SLAB SURFACES ------------- Area Slab Type (sf) Standard Slab 1361 Standard Slab 1462 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Project Title.......... Plan 8/Plan 8 casita HVAC SYSTEMS Refrigerant Equipment Minimum Charge and Duct Type Efficiency Airflow Location Furnace 0.800 AFUE n/a Attic ACSplit 12.00 SEER No Attic Living: Minimum Heating Load: 21,781 Btuh Cooling Load: 22,523(Sensible),27,028(Total) Bedrooms: Minimum Heating Load: 20,719 Btuh Cooling Load:17,239(Sensible),20,687(Total) casita: Minimum Heating Load: 8,614 Btuh Cooling Load: 7,929(Sensible), 9,515(Total) Page 2 CF-1R Date..09/12/02 11:53:36 Tested ACCA Duct Duct Manual Thermostat R-value Leakage D Type ------- ------- ---------------- R-4.2 Yes No Setback R-4.2 Yes No Setback Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. That individual is required to provide Form CF-6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF-6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the compliance documentation. DUCT TESTING DETAILS Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) ----------------- ------------------------- ----------------- Furnace / ACSplit 6% / 57.2 Furnace / ACSplit 6% / 61.4 WATER HEATING SYSTEMS --------------------- Number in Tank Type Heater Type Distribution Type System n/a n/a Energy Factor Storage Gas Recirc/TimeTemp 1 0.51 American Water Heater G52-75T75-4NV (or equal) Tank External Size Insulation (gal) R-value -- 75 R-12 *All piping used to recirculate hot water must be insulated with R-4 insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. jA timer must be permanently installed to regulate pump operation. Timer 'setting must permit the pump to be cycled for at least eight hours per day. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater 'through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------ ----------------------- This building incorporates Tested Duct Leakage. Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Plan 8/ Plan 8 w/casita Date..09/12/02 11:53:36 -------------- HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** HERS REQUIRED VERIFICATION -------------------------- This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the .CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title.......... Project Address........ I Documentation Author... ----------------------------- Plan 9/Plan 9 w/Casita Date..09/12/02 12:14:08 La Cala ******* --------------------- La Quinta *v6.01* Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone.......... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-21105MI1 Wth-CTZ15S92 Program -FORM CF-1R User#-MP0940 User -Heritage Energy Group Run--------------------------------------------------------------------------- - GENERAL INFORMATION ------------------- Conditioned Floor Area..... 3240 sf/3816 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 17.3 % of floor area Average Glazing U-factor... 0.36 Btu/hr-sf-F Average Glazing SHGC....... 0.35 Average Ceiling Height..... 10 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type ------- R-value -------- R-value -------- R-value ------- U-factor Location/Comments ------- ------------------------ ------------ S1abEdge None R-0 R-n/a F2=0.760 Wall Wood R-19 R-n/a R-19 0.065 Roof Wood R-30 R-n/a R-30 0.035 Door Wood R-0 R-n/a R-0 0.330 S1abEdge None R-0 R-n/a F2=0.510 FENESTRATION ------------ orientation Door Back (S) Wind Back (S) Door Right (W) Door Right (W) Wind Right (W) Wind Front (N) Wind Left (E) Wind Left (E) Wind Left (E) Wind Back (S) Area (sf) 268.0 78.0 48.0 48.0 26.8 29.0 108.0 6.7 4.0 45.0 U- Factor SHGC Exterior Shading Fins Location/Comments---------------------------- - -------------- 0.350 0.330 ----- Standard 0.350 0.320 Standard 0.350 0.330 Standard 0.550 0.650 Standard 0.350 0.310 Standard 0.350 0.310 Standard 0.350 0.310 Standard 0.350 0.320 Standard 0.350 0.310 Standard 0.350 0.310 Standard SLAB SURFACES Over- hang/ Yes vinyl framed low-e Yes vinyl framed low-e Yes vinyl framed low-e Yes non metal dual clear Yes vinyl framed low-e Yes vinyl framed low-e Yes vinyl framed low-e Yes vinyl framed low-e None vinyl framed low-e Yes vinyl framed low-e Area Slab Type (sf) ------ ---------------- Standard Slab 1384 Standard Slab 1856 Standard Slab 576 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Plan 9/ Plan 9 w/Casita Date..09/12/02 12:14:08 EquipmentMinimum-Minimum- Type Efficiency - -- Furnace ACSplit HPSplit HPSplit Living: Cooling HVAC SYSTEMS Refrigerant Charge and Duct Duct Airflow --Location- R_value Tested ACCA Duct Manual Thermostat Leakage D Type --- --- 0.800 AFUE n/a Attic R-4.2 Yes No Setback 12.00 SEER No Attic R-4.2 Yes No Setback 6.60 HSPF n/a Attic R-4.2 Yes No Setback 12.00 SEER No Attic R-4.2 Yes No Setback Minimum Heating Load: 23,016 Btuh Load: 22,596(Sensible),27,115(Total) Bedroom/retreat: Minimum Heating Load: 25,424 Btuh Cooling Load:21,440(Sensible),25,728(Total) Casita: Minimum Heating Load: 10,979 Btuh Cooling Load: 10,157(Sensible),12,188(Total) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. That individual is required to provide Form CF-6R, an Installation Certificate, which must be posted at the building site prior to issuance of the occupancy permit. The CF-6R is not required for permit submittal. It is intended to insure installation of equipment that meets the efficiency requirements of the compliance documentation. DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area Equipment Type (% fan CFM/CFM25) (ft2) ----------------- ------------------------- ----------------- Furnace / ACSplit 6% / 58.1 n/a Furnace / ACSplit 6% / 78.0 n/a HPSplit / HPSplit 6% / 24.2 n/a WATER HEATING SYSTEMS --------------------- Tank Type Heater Type Distribution Type ---------- ----------- ------------------- Number in Energy System Factor ------ -------- Storage Gas Recirc/TimeTemp 1 0.51 American Water Heater G52-75T75-4NV (or equal) Tank External Size Insulation (gal) ---------------- R-value -- 75 R-12 *All piping used to recirculate hot water must be insulated with R-4 insulation or equivalent. This includes any recirculating piping located in concrete slabs or underground. A timer must be permanently installed to regulate pump operation. Timer setting must permit the pump to be cycled for at least eight hours per day. An automatic thermostatic control must be installed to cycle the pump on and off in response to the temperature of the water returning to the water heater through the recirculation piping. Minimum differential or "Deadband" of the control shall not be less than 20 degrees F. SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------ ----------------------- This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates Tested Duct Leakage. Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Plan 9 w/Casita Date..09/12/02 12:14:08 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Plan 7 w/Casita Date..10/04/02 15.33:29 Project Address........ La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field -Check/ Date -- Climate Zone........... 15--------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. _____________ MICROPAS6 v6.01 File-21105MG1 Wth-CTZ15S92 Program -FORM C-2R User#-MP0940 User -Heritage Energy Group Run- ----------------------------------- --------------------------------------- _ MICROPAS6 ENERGY USE SUMMARY = ---------------------------- = Energy Use Standard Proposed - Compliance = - (kBtu/sf-yr) _----------------------- Design ---------- Design ---------- Margin = - = Space Heating.......... 3.98 2.98 ---------- 1.00 = = Space Cooling.......... 38.53 35.39 3.14 = = Water Heating.......... 9.14 9.15 -0.01 = = North Total 51.65 47.52 4.13 = = Space Heating.......... 3.98 3.52 0.46 = = Space Cooling.......... 38.53 37.68 0.85 = = Water Heating.......... 9.14 9.15 -0.01 = = East Total 51.65 50.35 1.30 = = Space Heating.......... 3.98 3.32 0.66 = = Space Cooling.......... 38.53 35.44 3.09 = - Water Heating.......... 9.14 9.15 -0.01 = = South Total 51.65 47.91 3.74 = = Space Heating.......... 3.98 3.13 0.85 = - Space Cooling.......... 38.53 38.17 0.36 = = Water Heating.......... 9.14 9.15 -0.01 = = West Total 51.65 50.45 1.20 = _ *** Building complies with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 3118 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 3 Conditioned Volume......... 31180 cf COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29 Slab -On -Grade --------------------------------------------------- Area......... 3118 sf Glazing Percentage......... 20.7 % of floor area Average Glazing U-factor... 0.36 Btu/hr-sf-F Average Glazing SHGC....... 0.34 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor ------------------------- # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone -------------- Type (sf) ----- (cf) ------- Units itioned Type (ft) (sf) ----- Credit 1 ------- ----------- ---------------------- Residence 1026 10260 0.33 Yes Setback 2.0 Standard No 2 Residence 1628 16280 0.52 Yes Setback 2.0 Standard No 3 Residence 464 4640 0.15 Yes Setback 2.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ Surface -------------- (sf) ------ factor ----- R-val Azm Tilt Gains ----- Reference Comments 1 --- ---- ----- ------------ -------•---------- 2 Wall 218 0.065 19 180 90 Yes None 3 Wall 120 0.065 19 270 90 Yes None 4 Wall 134 0.065 19 0 90 Yes None 5 Wall 50 0.065 19 90 90 Yes None 6 Roof 1033 0.035 30 n/a 0 Yes None 7 Door 28 0.330 0 0 90 Yes None 8 Door 17 0.330 0 0 90 No None 2 12 Wall 170 0.065 19 180 90 Yes None 13 Wall 494 0.065 19 270 90 Yes None 14 Wall 333 0.065 19 0 90 Yes None 15 Wall 571 0.065 19 90 90 Yes None 16 Wall 144 0.065 19 0 90 No None 17 Roof 1628 0.035 30 n/a 0 Yes None 3 18 Roof 464 0.035 30 n/a 0 Yes None 19 Wall 142 0.065 19 180 90 Yes None 20 Wall 270 0.065 19 270 90 Yes None 21 Wall 193 0.065 19 0 90 Yes None 22 Wall 270 0.065 19 90 90 Yes None PERIMETER LOSSES Length ---------------- F2 Insul Solar Surface (ft) ------------ ------ Factor R-val --------------- Gains ----- Location/Comments 1 ---------------------- 1 SlabEdge 70 0.510 R-0 No 2 9 SlabEdge 195 0.760 R-0 No 11 SlabEdge 16 0.510 R-0 No 3 10 SlabEdge 98 0.760 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29 --------------- Area Orientation (sf) ------------------ - 1 FENESTRATION SURFACES --------------------- Exterior U- Act Shade factor SHGC Azm Tilt Type---- Location/Comments --- --- ---------------------------- 1 Door Back (S) 64.0 0.350 0.330 180 90 Standard vinyl framed low-e 2 Wind Back (S) 39.0 0.350 0.320 180 90 Standard vinyl framed low-e 3 Wind Back (S) 39.0 0.350 0.320 180 90 Standard vinyl framed low-e 11 Wind Front (N) 36.0 0.350 0.310 0 90 Standard vinyl framed low-e 2 4 Door Back (S) 80.0 0.350 0.330 5 Door Back (S) 80.0 0.350 0.330 8 Wind Right (W) 36.0 0.350 0.310 9 Wind Right (W) 50.0 0.350 0.310 10 Wind Right (W) 9.9 0.350 0.310 12 Wind Front (N) 9.5 0.350 0.310 13 Door Front (N) 48.0 0.550 0.650 16 Wind Left (E) 25.0 0.350 0.310 17 Wind Left (E) 11.4 0.350 0.310 18 Wind Left (E) 12.5 0.350 0.310 3 6 Door Back (S) 48.0 7 Wind Back (S) 30.0 14 Wind Front (N) 9.0 15 Wind Front (N) 18.0 Surface---- 1 1 Door 2 Window 11 Window 2 4 Door 5 Door 12 Window 13 Door 3 6 Door 7 Window 14 Window 15 Window 180 90 Standard vinyl framed low-e 180 90 Standard vinyl framed low-e 270 90 Standard vinyl framed low-e 270 90 Standard vinyl framed low-e 270 90 Standard vinyl framed low-e 0 90 Standard vinyl framed low-e 0 90 Standard Non metal framed clear 90 90 Standard vinyl framed low-e 90 90 Standard vinyl framed low-e 90 90 Standard vinyl framed low-e 0.350 0.330 180 90 Standard vinyl framed low-e 0.350 0.310 180 90 Standard vinyl framed low-e 0.350 0.310 0 90 Standard vinyl framed low-e 0.350 0.310 0 90 Standard vinyl framed low-e OVERHANGS AND SIDE FINS ---Window-- ----------------------- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght (sf) ----- Wdth ----- Hgth ----- Dpth Hght ---- ---- Ext ---- Ext ---- Ext ---- Dpth ---- Hght ---- Ext ---- Dpth ---- Hght ---- 64.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 39.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 36.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 80.0 n/a 8 5 1 n/a n/a n/a n/a. n/a n/a n/a n/a 80.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 9.5 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 48.0 n/a 6 1 1 n/a n/a n/a n/a. n/a n/a n/a n/a 48.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a. n/a n/a 30.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 9.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 18.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type ---------------- (sf) ------ 1 Standard Slab 1026 2 Standard Slab 1628 3 Standard Slab 464 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Plan 7 w/Casita -------------- Date..10/04/02 15:33:29 HVAC SYSTEMS ------------ Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type ------------- Efficiency ----------- Airflow Location R-value -------------------- Leakage D Eff 1 ------- ---------------- ---- Furnace 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 ACSplitTXV 12.00 SEER Yes Attic R-4.2 Yes No 0.703 2 Furnace 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 ACSplitTXV 12.00 SEER Yes Attic R-4.2 Yes No 0.703 3 HPSplit 6.60 HSPF n/a Attic R-4.2 Yes No 0.847 HPSplit 12.00 SEER No Attic R-4.2 Yes No 0.703 DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area Equipment Type ------------------------ (% fan CFM/CFM25) ------------------ (ft2) 1 ----------------- Furnace / ACSplitTXV 6% / 43.1 n/a 2 Furnace / ACSplitTXV 6% / 68.4 n/a 3 HPSplit / HPSplit 6% / 19.5 n/a WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ---------------------------------------- -------------- ---------------- 1 Storage Gas Recirc/TimeTemp 1 0.51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system (s) . ndatory Measures require a R-12 or greater external blanket on Gas Storage ter Heaters with Energy Factors less than 0.58. HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Plan 7 w/Casita Date..10/04/02 15:33:29 HERS REQUIRED VERIFICATION -------------------------- *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for. Tested Duct Leakage. This building incorporates either Tested Refrigerant Charge and Airflow (RCA) or a Thermostatic Expansion Valve (TXV) on the specified air conditioning system(s). If a cooling system is not installed, then HERS verification is not necessary for the RCA or TXV. REMARKS COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Project Address........ Plan 8 Date..09/12/02 11:53:36 La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Rudy Sains ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 Climate Zone.... ..... 949-789-7221 15 --------------------- Field Check/ Date Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-21105M81 Wth-CTZ15S92 Program -FORM C-2R ----------------User#-MP0940 User -Heritage Energy Group Run- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) ------------------------ Design ---------- Design Margin = = Space Heating.......... 2.74 ---------- 2.19 ---------- - 0.55 = = Space Cooling.......... 34.86 32.59 2.27 = = Water Heating.......... 10.09 10.10 -0.01 = = North Total 47.69 44.88 - 2.81 = = Space Heating.......... 2.74 2.79 -0.05 = = Space Cooling.......... 34.86 34.14 0.72 = = Water Heating.......... 10.09 10.10 -0.01 = = East Total 47.69 47.03 0.66 = = Space Heating.......... 2.74 2.95 -0.21 = = Space Cooling.......... 34.86 31.79 3.07 = = Water Heating.......... 10.09 10.10 -0.01 = = South Total 47.69 44.84 2.85 = = Space Heating.......... 2.74 2.55 0.19 = = Space Cooling.......... 34.86 34.11 0.75 = = Water Heating.......... 10.09 10.10 -0.01 = = West Total 47.69 46.76 0.93 = _ *** Building complies with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 2823 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 28230 cf COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Plan 8-----Date__09/12/02 11:53:36 ------------------------------------------------------- Slab -On -Grade Area......... 2823 sf Glazing Percentage......... 20.8 % of floor area Average Glazing U-factor... 0.35 Btu/hr-sf-F Average Glazing SHGC....... 0.32 Average Ceiling Height..... 10 ft Floor Area Zone Type (sf) -------------- ----- 1 Residence 1361 2 Residence 1462 Surface 1 2 Wall 3 Wall 4 Wall 5 Roof 6 Door 7 Door 2 10 Wall 11 Wall 12 Wall 13 Wall 14 Wall 15 Roof BUILDING ZONE INFORMATION ------------------------- # of Vent Vent Air Volume Dwell Cond- Thermostat Height Area Leakage (cf) Units itioned Type (ft) (sf) Credit ------- ----- ----------------- ----- -------- --------- 13610 0.48 Yes Setback 2.0 Standard No 14620 0.52 Yes Setback 2.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ (sf) ------ factor ----- R-val ----- Azm --- Tilt ---- Gains ----- Reference Comments ------------ ---------------- 195 0.065 19 180 90 Yes None 346 0.065 19 270 90 Yes None 242 0.065 19 0 90 Yes None 1316 0.031 30 n/a 0 Yes None 27 0.330 0 0 90 Yes None 17 0.330 0 0 90 No None 206 0.065 19 180 90 Yes None 166 0.065 19 270 90 Yes None 387 0.065 19 90 90 Yes None 270 0.065 19 0 90 No None 153 0.065 19 90 90 No None 1462 0.035 30 n/a 0 Yes None Length Surface (ft) ------------ ------ 1 1 S1abEdge 114 2 8 S1abEdge 97 9 S1abEdge 47 PERIMETER LOSSES ---------------- F2 Insul Solar Factor R-val Gains Location/Comments --------------- --------------------------- 0.760 R-0 No 0.760 R-0 No 0.510 R-0 No FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type 1 ---- ----- --- ------------ Location/Comments ------------------------ 1 2 Door Wind Back (S) 128.0 0.350 0.330 180 90 Standard Vinyl framed low-e Back (S) 15.0 0.350 0.320 180 90 Standard vinyl framed low-e 3 Door Back (S) 72.0 0.350 0.330 180 90 Standard Vinyl framed low-e 6 Wind Right (W) 20.0 0.350 0.310 270 90 Standard vinyl framed low-e 7 Wind Right (W) 24.0 0.350 0.310 270 90 Standard vinyl framed low-e 9 Wind Front (N) 128.0 0.350 0.310 0 90 Standard vinyl framed low-e COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Plan 8 Date..09/12/02 11:53:36 FENESTRATION SURFACES Exterior Area U- Act Shade Orientation -(sf) factor SHGC --- ----- Azm Tilt Type Location/Comments 10 Wind Front (N) 10.5 0.350 0.310 --- 0 ---- 90 -------- Standard ------------------------ vinyl framed low-e 2 4 Door Back (S) 64.0 0.350 0.330 180 90 Standard Vinyl framed low-e 5 Wind Back (S) 20.0 0.350 0.310 180 90 Standard vinyl framed low-e 8 Door Right (W) 64.0 0.350 0.330 270 90 Standard Vinyl framed low-e 11 Wind Left (E) 30.0 0.350 0.310 90 90 Standard vinyl framed low-e 12 Wind Left (E) 12.9 0.350 0.310 90 90 Standard vinyl framed low-e OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin --- Area Left Rght ---Right Fin -- Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 1 Door 128.0 n/a 2 Window 15.0 n/a 3 Door 72.0 n/a 6 Window 20.0 n/a 7 Window 24.0 n/a 9 Window 128.0 n/a 10 Window 10.5 n/a 2 5 Window 20.0 n/a 8 Door 64.0 n/a 11 Window 30.0 n/a System Type --- ------ 1 Furnace ACSplit 2 Furnace ACSplit 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 5 5 0 n/a n/a n/a n/a n/a n/a n/a n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 5 1 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type ---------------- (sf) ------ 1 Standard Slab 1361 2 Standard Slab 1462 HVAC SYSTEMS ------------ Refrigerant Tested ACCA Minimum Charge and Duct Duct Duct Manual Duct Efficiency ------- Airflow Location -------------------- R-value ------- Leakage --------- D -------- Eff ---- 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 12.00 SEER No Attic R-4.2 Yes No 0.703 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 12.00 SEER No Attic R-4.2 Yes No 0.703 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Plan 8 Date..09/12/02 11:53:36 -------------- Equipment Type 1 Furnace / ACSplit 2 Furnace / ACSplit DUCT TESTING DETAILS -------------------- Duct Leakage Target (% fan CFM/CFM25) ------------------ 6% / 57.2 6% / 61.4 Measured Supply Duct Surface Area (ft2) ----------------- WATER HEATING SYSTEMS --------------------- Number in Tank Type Heater Type Distribution Type System ------------ ----------- ------------------- ------ 1 Storage Gas Recirc/TimeTemp 1 n/a n/a Tank External Energy Size Insulation Factor (gal) -------- R-value ------ 0.51 75 ---------- R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates Tested Duct Leakage. Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy .rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary ,for Tested Duct Leakage. REMARKS COMPUTER METHOD SUMMARY Page 1 C-2R ------------------------------------------------------------ Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42 Project Address........ La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check Date Climate Zone. ...... 15 ------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-21105MH1 Wth-CTZ15S92 Program -FORM C-2R ----------------User#_MP0940 User -Heritage Energy Group Run- = _ MICROPAS6 ENERGY USE ------------------ SUMMARY = ---------------------------- = Energy Use Standard Proposed - Compliance = _ (kBtu/sf-yr) _--------------------------------- Design Design Margin = = Space Heating.......... 3.51 ---------- 2.60 ---------- - 0.91 = = Space Cooling.......... 36.50 34.75 1.75 = = Water Heating.......... 8.88 8.89 -0.01 = = North Total 48.89 46.24 2.65 = = Space Heating.......... 3.51 3.31 0.20 = = Space Cooling.......... 36.50 36.67 -0.17 = = Water Heating.......... 8.88 8.89 -0.01 = = East Total 48.89 48.87 0.02 = = Space Heating.......... 3.51 3.49 0.02 = = Space Cooling.......... 36.50 33.48 3.02 = = Water Heating.......... 8.88 8.89 -0.01 = = South Total 48.89 45.86 3.03 = = Space Heating.......... 3.51 3.05 0.46 = = Space Cooling.......... 36.50 36.65 -0.15 = = Water Heating.......... 8.88 8.89 -0.01 = = West Total 48.89 48.59 0.30 = *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 3208 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 3 Conditioned Volume......... 32090 cf COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42 ----------------------------------------------- Slab -On -Grade Area......... 3208 sf Glazing Percentage......... 20.4 % of floor area Average Glazing U-factor... 0.36 Btu/hr-sf-F Average Glazing SHGC....... 0.33 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit -------------- ------------ ----------------------- ---------------------- 1 2 Residence 1361 13620 0.43 Yes Setback 2.0 Standard No 3 Residence 1462 14620 0.45 Yes Setback 2.0 Standard No Residence 385 3850 0.12 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ----------------- ---------------- 1 2 Wall 195 0.065 19 180 90 Yes None exterior: 3 Wall 346 0.065 19 270 90 Yes None 4 Wall 242 0.065 19 0 90 Yes None 5 Roof 1361 0.031 30 n/a 0 Yes None Attic: 6 Door 27 0.330 0 0 90 Yes None frt door 2 7 Door 17 0.330 0 0 90 No None garage door 11 Wall. 206 0.065 19 180 90 Yes None Exterior: 12 Wall 166 0.065 19 270 90 Yes None 13 Wall 387 0.065 19 90 90 Yes None 14 Wall 270 0.065 19 0 90 No None Garage/house 15 Wall 153 0.065 19 90 90 No None Garage/house 16 Roof 1462 0.031 30 n/a 0 Yes None Attic: 3 17 Roof 385 0.035 30 n/a 0 Yes None Attic: 18 Wall 191 0.065 19 180 90 Yes None 19 Wall 180 0.065 19 270 90 Yes None 20 Wall 223 0.065 19 0 90 Yes None 21 Wall 180 0.065 19 90 90 Yes None PERIMETER LOSSES ---------------- Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1 1 SlabEdge 114 0.760 R-0 No to outside 2 8 SlabEdge 97 0.760 R-0 No 10 SlabEdge 47 0.510 R-0 No 3 9 SlabEdge 80 0.760 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42 --------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ------------ ------------------------ 1 1 Door Back (S) 128.0 0.350 0.330 180 90 Standard vinyl framed low-e 2 Wind Back (S) 15.0 0.350 0.320 180 90 Standard vinyl framed low-e 3 Door Back (S) 72.0 0.350 0.330 180 90 Standard vinyl framed low-e 6 Wind Right (W) 20.0 0.350 0.310 270 90 Standard vinyl framed low-e 7 Wind Right (W) 24.0 0.350 0.310 270 90 Standard vinyl framed low-e 9 Wind Front (N) 128.0 0.350 0.310 0 90 Standard vinyl framed low-e 10 Wind Front (N) 10.5 0.350 0.310 0 90 Standard vinyl framed low-e 2 4 Door Back (S) 64.0 0.350 0.330 180 90 Standard vinyl framed low-e 5 Wind Back (S) 20.0 0.350 0.310 180 90 Standard vinyl framed low-e 8 Door Right (W) 64.0 0.350 0.330 270 90 Standard vinyl framed low-e 11 Wind Left (E) 30.0 0.350 0.310 90 90 Standard vinyl framed low-e 12 Wind Left (E) 12.9 0.350 0.310 90 90 Standard vinyl framed low-e 3 13 Wind Back (S) 25.0 0.350 0.310 180 90 Standard vinyl framed low-e 14 Door Back (S) 24.0 0.550 0.650 180 90 Standard non metal dual clear 15 Wind Front (N) 13.5 0.350 0.310 0 90 Standard vinyl framed low-e 16 Wind Front (N) 3.8 0.350 0.320 0 90 Standard vinyl framed low-e OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 1 Door 128.0 n/a 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 15.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 72.0 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 20.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 24.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 128.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 10.5 n/a 6 1 1 n/a n/a n/a n/a n/a n/a n/a n/a 2 5 Window 20.0 n/a 5 5 0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Door 64.0 n/a 8 8 1 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 30.0 n/a 5 1 2 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 1361 2 Standard Slab 1462 3 Standard Slab 385 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42 System Minimum Type ------------- Efficiency ----------- 1 Furnace 0.800 AFUE ACSplit 12.00 SEER 2 Furnace 0.800 AFUE ACSplit 12.00 SEER 3 HPSplit 6.60 HSPF HPSplit 12.00 SEER Equipment Type 1 Furnace / ACSplit 2 Furnace / ACSplit 3 HPSplit / HPSplit HVAC SYSTEMS ------------ Refrigerant Tested ACCA Charge and Duct Duct Duct Manual Duct Airflow Location -------------------- R-value ------- Leakage --------- D -------- Eff ---- n/a Attic R-4.2 Yes No 0.815 No Attic R-4.2 Yes No 0.703 n/a Attic R-4.2 Yes No 0.815 No Attic R-4.2 Yes No 0.703 n/a Attic R-4.2 Yes No 0.847 No Attic R-4.2 Yes No 0.703 DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area (% fan CFM/CFM25) (ft2) ----------------------------------- 6% / 57.2 n/a 6% / 61.4 n/a 6% / 16.2 n/a WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ------------------------------------------ -------------- ---------------- 1 Storage Gas Recirc/TimeTemp 1 0.51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates Tested Duct Leakage. 'Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Plan 8 w/Casita Date..09/12/02 11:54:42 HERS REQUIRED VERIFICATION -------------------------- or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. REMARKS COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Plan 9 Date..09/12/02 11.56.54 Project Address........ La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. --- MICROPAS6 v6.01 File-21105M91 Wth-CTZ15S92 Program -FORM C-2R ----User#-MP0940 User -Heritage Energy Group Run- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design ---------- Margin = = Space Heating.......... 2.81 2.35 ---------- - 0.46 = = Space Cooling.......... 35.31 33.81 1.50 = = Water Heating.......... 8.79 8.80 -0.01 = = North Total 46.91 44.96 1.95 = = Space Heating.......... 2.81 2.62 0.19 = = Space Cooling.......... 35.31 33.35 1.96 = = Water Heating.......... 8.79 8.80 -0.01 = = East Total 46.91 44.77 2.14 = = Space Heating.......... 2.81 3.00 -0.19 = = Space Cooling.......... 35.31 33.40 1.91 = = Water Heating.......... 8.79 8.80 -0.01 = = South Total 46.91 45.20 1.71 = = Space Heating.......... 2.81 2.54 0.27 = = Space Cooling.......... 35.31 33.37 1.94 = = Water Heating.......... 8.79 8.80 -0.01 = = West Total 46.91 44.71 2.20 = _ *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 3240 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 32400 cf COMPUTER METHOD SUMMARY Page 2 C-2R Project Title.......... Plan 9---------Date..09/12/02 11:56:54 ------------------------------------------------------ Slab -On -Grade Area......... 3240 sf Glazing Percentage......... 16.5 % of floor area Average Glazing U-factor... 0.36 Btu/hr-sf-F Average Glazing SHGC....... 0.34 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) --- Units itioned ------------ Type (ft) (sf) Credit 1 ----------- ----- ----------------- Residence 1384 13840 0.43 Yes Setback 2.0 Standard No 2 Residence 1856 18560 0.57 Yes Setback 2.0 Standard No OPAQUE SURFACES Area U- --------------- Insul Act Solar Form 3 Location/ Surface (sf) factor ---- R-val Azm Tilt ----- --- ---- Gains Reference Comments 1 ----- ------------ ---------------- 2 Wall 170 0.065 19 180 90 Yes None exterior: 3 Wall 358 0.065 19 270 90 Yes None 4 Wall 150 0.065 19 0 90 Yes None 5 Wall 687 0.065 19 90 90 Yes None 6 Roof 1384 0.035 30 n/a 0 Yes None Attic: 7 Door 27 0.330 0 0 90 Yes None frt door 8 Door 17 0.330 0 0 90 No None garage door 11 Wall 260 0.065 19 180 90 Yes None Exterior: 12 Wall 349 0.065 19 270 90 Yes None 13 Wall 361 0.065 19 0 90 Yes None 14 Wall 274 0.065 19 90 90 Yes None 15 Wall 225 0.065 19 0 90 No None Garage/house 16 Roof 1856 0.035 30 n/a 0 Yes None Attic: PERIMETER LOSSES Length ---------------- F2 Insul Solar Surface -(ft)- Factor R-val Gains Location/Comments 1 1 SlabEdge 2 9 SlabEdge 10 SlabEdge 116 0.760 R-0 136 0.760 R-0 25 0.510 R-0 No to outside No No FENESTRATION SURFACES ---------------------- Exterior Area U- Act Shade Orientation -(sf) factor SHGC Azm Tilt Type Location/Comments 1 Door Back (S) 80.0 0.350 0.330 180 90 Standard vinyl framed low-e 2 Wind Back (S) 78.0 0.350 0.320 180 90 Standard vinyl framed low-e 3 Door Back (S) 52.0 0.350 0.330 180 90 Standard vinyl framed low-e 5 Door Right (W) 48.0 0.350 0.330 270 90 Standard vinyl framed low-e 6 Door Right (W) 24.0 0.550 0.650 270 90 Standard non metal dual clear COMPUTER METHOD SUMMARY I Page 3 C-2R Project Title.......... Plan 9 Date..09/12/02 11:56:54 FENESTRATION SURFACES Exterior Orientation Area (sf) -- U- factor SHGC ----- Act Azm Tilt Shade Type Location/Comments 10 11 Wind Wind Left Left (E) (E) 36.0 6.7 0.350 0.350 ----- 0.310 --- 90 ---- 90 - - -------- Standard ------------------ Vinyl framed low-e 2 0.320 90 90 Standard vinyl framed low-e 4 7 Door Wind Back Right (S) (W) 80.0 24.0 0.350 0.330 180 90 Standard vinyl framed low-e 8 Wind Right (W) 6.7 0.350 0.350 0.310 270 90 Standard Vinyl framed low-e 9 Wind Front (N) 24.0 0.350 0.320 0.310 270 0 90 90 Standard Standard vinyl Vinyl framed framed low-e low-e 12 13 Wind Wind Left Left (E) (E) 72.0 4.0 0.350 0.350 0.310 90 90 Standard Vinyl framed low-e 0.310 90 90 Standard Vinyl framed low-e Area Surface (sf) ----------- - 1 OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Left Rght Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 Door 2 Window 80.0 n/a 78.0 n/a 8 6 12 1 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 52.0 n/a 6 1 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 6 Door 48.0 n/a 24.0 n/a 8 6 10 1 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 36.0 n/a 8 1 10 1 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 2 6.7 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 7 Window 80.0 n/a 24.0 n/a 8 6 9 1 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 6.7 n/a 1.6 1 1.5 1.0 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 72.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type ---------------- (sf) ------ 1 Standard Slab 1384 2 Standard Slab 1856 HVAC SYSTEMS System Minimum ------------ Refrigerant Charge and Duct Duct Tested Duct ACCA Manual Duct Type ---------- Efficiency ----------- Airflow Location ------- R-value Leakage D Eff ------------- ------- --------- -------- ---- Furnace ACSplit 0.800 AFUE 12.00 SEER n/a Attic No Attic R-4.2 Yes No 0.815 2 R-4.2 Yes No 0.703 (Furnace ACSplit 0.800 AFUE 12.00 n/a Attic R-4.2 Yes No 0.815 SEER No Attic R-4.2 Yes No 0.703 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Plan 9 Date..09/12/02 11:56:54 Equipment Type 1 Furnace / ACSplit 2 Furnace / ACSplit DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area (% fan CFM/CFM25) (ft2) ----------------------------------- 6% / 58.1 6% / 78.0 WATER HEATING SYSTEMS n/ a n/ a Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value ---------------------- ------ -- ---- ------ ------ 1 Storage Gas Recirc TimeTemp 1 0.51 75 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This is a multiple orientation building with no orientation restrictions. This printout is for the front facing North. This building incorporates Tested Duct Leakage. Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the (compliance calculations could be redone without duct testing. IIf ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. REMARKS COMPUTER METHOD SUMMARY Page 1 C-2R Project Title.......... Plan 9 w/Casita Date..09/12/02 12:14:08 Project Address........ La Cala ******* --------------------- La Quinta *v6.01* Documentation Author... Sam Maimone ******* Building Permit Heritage Energy Group 15375 Barranca Pkwy, Suite F-101 Plan Check / Date Irvine, CA 92618 949-789-7221 Field Check/ Date Climate Zone. .. ..... 15 --------------------- Compliance Method ...... -MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-21105M11 Wth-CTZ15S92 Program -FORM C-2R ------User#-MP0940 User -Heritage Energy Group Run - MICROPAS6 ENERGY USE SUMMARY - Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design --------- Design Margin = = Space Heating.......... 3.55 ---------- 2.67 ---------- 0.88 = = Space Cooling.......... 36.31 35.53 0.78 = = Water Heating.......... 7.47 7.47 0.00 = = North Total 47.33 45.67 1.66 = = Space Heating.......... 3.55 3.20 0.35 = = Space Cooling.......... 36.31 35.20 1.11 = = Water Heating.......... 7.47 7.47 0.00 = = East Total 47.33 45.87 1.46 = = Space Heating.......... 3.55 3.55 0.00 = = Space Cooling.......... 36.31 34.69 1.62 = = Water Heating.......... 7.47 7.47 0.00 = South Total 47.33 45.71 1.62 = = Space Heating.......... 3.55 2.88 0.67 = = Space Cooling.......... 36.31 35.42 0.89 = = Water Heating.......... 7.47 7.47 0.00 = = West Total 47.33 45.77 1.56 = _ *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... 3816 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 3 Conditioned Volume......... 38160 cf COMPUTER METHOD SUMMARY Page 2 Project Title.......... Plan 9 w/Casita ------------------------------------------ Date..09/12/02 C-2R 12:14:08 Slab -On -Grade Area......... 3816 ____________________ sf Glazing Percentage......... 17.3 % of floor area Average Glazing U-factor... 0.36 Btu/hr-sf-F Average Glazing SHGC....... 0.35 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor ------------------------- # of Vent Vent Air Area Zone Type (sf) Volume Dwell Cond- Thermostat Height Area Units itioned Leakage -(cf)-- ------------ Type (ft) (sf) Credit 1 ----------- ---------------------- Residence 1384 13840 0.36 Yes Setback 2.0 Standard No 2 Residence 1856 18560 0.49 Yes Setback 2.0 Standard No 3 Residence 576 5760 0.15 Yes Setback 2.0 Standard No OPAQUE SURFACES Surface Area (sf) U- factor --------------- Insul Act Solar Form 3 Location/ R-val Azm Tilt Gains Reference ---- ----- Comments 1 ------------ ---------------- 2 Wall 170 0.065 19 180 90 Yes None 3 Wall 358 0.065 19 270 90 Yes None 4 Wall 150 0.065 19 0 90 Yes None 5 Wall 687 0.065 19 90 90 Yes None 6 Roof 1384 0.035 30 n/a 0 Yes None 7 Door 27 0.330 0 0 90 Yes None 8 Door ' 17 0.330 0 0 90 No None 2 13 Wall 114 260 0.065 19 180 90 Yes None Wall 353 0.065 19 270 90 Yes None 115 Wall 361 0.065 19 0 90 Yes None 16 Wall 274 0.065 19 90 90 Yes None 17 Wall 225 0.065 19 0 90 No None 18 Roof 1856 0.035 30 n/a 0 Yes None 3 19 Roof 576 0.035 30 n/a 0 Yes None 20 Wall 229 0.065 19 180 90 Yes None 21 Wall 206 0.065 19 270 90 Yes None 22 Wall 115 0.065 19 0 90 Yes None 23 Wall 170 0.065 19 90 90 Yes None PERIMETER LOSSES Length ---------------- F2 Insul Solar Surface -(ft) Factor R-val --------------- Gains Location/Comments 1 ----- ---------------------- 1 SlabEdge 116 0.760 R-0 No 2 9 SlabEdge 136 0.760 R-0 No 11 SlabEdge 25 0.510 R-0 No 12 SlabEdge 25 0.510 R-0 No 3 10 SlabEdge 86 0.760 R-0 No COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Plan 9 w/Casita Date..09 12 02 12:14:08 FENESTRATION SURFACES --------------------- Exterior Area U- Act Shade Orientation -(sf) factor SHGC Azm Tilt Type Location/Comments ----- ----- --- ------------ ------------------------ 1 1 Door Back (S) 80.0 0.350 0.330 180 90 Standard vinyl framed low-e 2 Wind Back (S) 78.0 0.350 0.320 180 90 Standard vinyl framed low-e 3 Door Back (S) 52.0 0.350 0.330 180 90 Standard vinyl framed low-e 5 Door Right (W) 48.0 0.350 0.330 270 90 Standard vinyl framed low-e 6 Door Right (W) 24.0 0.550 0.650 270 90 Standard non metal dual clear 9 Wind Left (E) 36.0 0.350 0.310 90 90 Standard vinyl framed low-e 10 Wind Left (E) 6.7 0.350 0.320 90 90 Standard vinyl framed low-e 2 J4 Door Back (S) 80.0 0.350 0.330 180 90 Standard vinyl framed low-e 7 Wind Right (W) 26.8 0.350 0.310 270 90 Standard vinyl framed low-e 8 Wind Front (N) 24.0 0.350 0.310 0 90 Standard vinyl framed low-e 11 Wind Left (E) 72.0 0.350 0.310 90 90 Standard vinyl framed low-e 12 Wind Left (E) 4.0 0.350 0.310 90 90 Standard vinyl framed low-e 3 13 Wind Back (S) 45.0 0.350 0.310 180 90 Standard vinyl framed low-e 14 Door Back (S) 56.0 0.350 0.330 180 90 Standard vinyl framed low-e 15 Door Right (W) 24.0 0.550 0.650 270 90 Standard non metal dual clear 16 Wind Front (N) 5.0 0.350 0.310 0 90 Standard vinyl framed low-e OVERHANGS AND SIDE FINS ----------------------- ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght .surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1 Door 80.0 n/a 8 12 1 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 78.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 3 Door 52.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 n/a 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 24.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 36.0 n/a 8 10 1 n/a n/a n/a n/a n/a n/a n/a n/a .0 Window 6.7 n/a 1.5 1.5 1..0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 80.0 n/a 8 9 1 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 26.8 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 24.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a '_1 Window 72.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 1.3 Window 45.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 56.0 n/a 8 4 1 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 24.0 n/a 8 4 1 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 5.0 n/a 6 1.5 1 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ 1 Standard Slab 1384 2 Standard Slab 1856 3 COMPUTER METHOD SUMMARY Page 4 C-2R Project Title.......... Plan 9 w/Casita Date..09 12 02 12.14:08 System Type ------------- Furnace ACSplit 2 Furnace ACSplit 3 HPSplit HPSplit SLAB SURFACES ------------- Area Slab Type (sf) ---------------- ------ Standard Slab 576 HVAC SYSTEMS ------------ Refrigerant Tested ACCA Minimum Charge and Duct Duct Duct Manual Duct Efficiency ----------- Airflow ------- Location ------------- R-value ------- Leakage --------- D -------- Eff ---- 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 12.00 SEER No Attic R-4.2 Yes No 0.703 0.800 AFUE n/a Attic R-4.2 Yes No 0.815 12.00 SEER No Attic R-4.2 Yes No 0.703 6.60 HSPF n/a Attic R-4.2 Yes No 0.847 12.00 SEER No Attic R-4.2 Yes No 0.703 Equipment Type 1 2 Furnace / ACSplit Furnace / ACSplit 3 HPSplit / HPSplit Tank Type Heater Type ----------------------- 1 Storage Gas DUCT TESTING DETAILS -------------------- Duct Measured Supply Leakage Target Duct Surface Area (% fan CFM/CFM25) (ft2) ----------------------------------- 6% / 58.1 6% / 78.0 6% / 24.2 WATER HEATING SYSTEMS --------------------- Number in Distribution Type System ------------------- ------ Recirc/TimeTemp 1 n/a n/a n/a Tank External Energy Size Insulation Factor (gal) -------- ------ R-value 0.51 75 ---------- R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** Phis is a multiple orientation building with no orientation restrictions. Phis printout is for the front facing North. Phis building incorporates Tested Duct Leakage. 4andatory Measures require a R-12 or greater external blanket on Gas Storage 4ater Heaters with Energy Factors less than 0.58. COMPUTER METHOD SUMMARY Page 5 C-2R Project Title.......... Plan 9 w/Casita Date..09/12/02 12:14:08 HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF-6R installation certificate. *** This building incorporates Tested Duct Leakage. Target CFM leakage values measured at 25 pascals are shown in DUCT TESTING DETAILS above or may be calculated as documented on the CF-6R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary for Tested Duct Leakage. REMARKS