HomeMy WebLinkAboutPGA West - Nicklaus - Heritage Collection TR 28340_29003 (Plans 1-3) Title 24The Heritage Collection at PGA West La Quinta Climate Zone 15 Brookfield Homes Energy Documentation: Compliance Method - MICROPAS v4.5 March 19, 1999 Haynal and Company, Inc. 2171 India Street, Suite A San Diego, CA 92101 (619) 531-1126 Contractor's License #649028 APR-09-99 11:00 AM HAYNAL & CO. 619 237 8879 P.01 MINIMUM REQUIREMENTS SUMMARY: TITLE 24 COMPLIANCE Each of the follo wing specific Items, the MF- I R page, and the signed CF- I R pages must be clearly listed on the plans, and provided to the homeowners upon assuming occupancy. p The Heritage Collection at PGA West ,bh, R-38 ?g1141�: ivy R-19, with R-4,68 Falcon foam at stuccoed walls '�'h J .,N ag . `.'i',;.` Exposed Slab: Plan 1 Plan 2 Plan 3. Entry 70 58 42 Kitchen 139 118 161 Nook 0 0 150 Hearth 9 8 0 Wet Bar 23 15 18 M Bath WC. 16 15 13 Bath 2 WC 21 30 22 Bath 3 37 18 33 Laundry 40 48 44 Total sf: 355 310 483 Description frame tint coatin , Ref U-Val Ref Front Doors wood none none 0.88 default 0.55 default Fr Dr Transoms alum none none 0.88 default 0.72 default Patio doors: loft alum bronze Hard E 0.66 mfr 0.53 mfr Other Patio doors alum bronze LoE2 0,47 mfr 0.58 mfr Butted glazing alum bronze Hard E 0.66 mfr 0.67 default Other oper glaze alum bronze LoE2 0.47 mfr 0,60 mfr Other fixed glaze alum bronze LoE2 0.47 mfr 0.43 mfr Skylight alum bronze none 0,72 default 0,80 default ,odd ro Summary (4/9/99): Glass Block none none none 0.88 default 0.57 default ate seater ,' I Main house, and serving G2 where occurs: 75 gal gas, recirculation system. Standard EF = .52. R-12 external blanket Recirc has R-4 on hot water mains, Timeclock + Temperature control Where G3 occurs: 40 gal gas. Standard EF = .535, R-12 external blanket j AFUE = 80% SEER = 12,0 R-4.2 Setback Living and Sleeping zones are on separate systems. Except when G3 occurs: zonal control not assumed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF-1R Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements �ted on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features Iced shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. IDESCRIPTION I DESIGNER I ENFORCEMENT I Building Envelope Measures *I50(a): Minimum R-19 ceiling insulation. X 150(b): Loose fill insulation manufacturers labeled R-Value. X * 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). X *150(d): Minimum R-13 raised floor insulation in framed floors; min. R-8 in concrete raised floors. X 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. X 116-17: Fenestration Products, Exterior Doors and Infiltration/exfiltration controls a. Doors & windows between conditioned and unconditioned spaces designed to limit air leakage b. Manufactured fenestration products have label with certified U-value,and infiltration certification c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. X 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(0: Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures �0-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC X 0(i): Setback thermostat on all applicable heating systems. X 1500): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulate (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. X * 150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. X 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78%thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. �. Pool system has directional inlets and a circulation pump time switch. '9: Gas -fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot 150 Btu/hr.). X Lighting Measures 150(k): 40 lumens watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. X )NSTRUCTION ASSEMBLY Page 2 3R act Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM 3R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Parallel Path Method Reference Name . W.19.2X6.16F Description .... Wall R-19 2x6 16ocw/FomeC Type ........... Wall R-Value ........ 22.48 Hr-sf-F/Btu Framing Material ..... FIR.2X6 Type ......... Wood Description .. 2x6 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 Sketch of Construction Assembly IST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R-Value R-Value J. FILM.EX Exterior air film: winter value 0.17 0.17 1. STUCCO.0.37 0.375 in stucco 0.08 0.08 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. R4.68 FOAM R-4.68 Foam Sheathing, Type II EPS 4.68 4.68 Ic. BATT.R19 R-19 batt insul (cavity = 5.5 in) 17.80 If. FIR.2X6 2x6 fir -- 5.45 5. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R-Values 23.92 11.56 RAMING ADJUSTMENT CALCULATION Cavity Framing Total -Value: (1 / 23.92 x 0.85) + (1 / 11.56 x 0.15) = 0.049 Btu/hr-sf-F Dtal R-Value: 1 / 0.049 = 20.62 hr-sf-F/Btu DNSTRUCTION ASSEMBLY Page 1 3R rct Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM 3R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Parallel Path Method Reference Name . W.19.2X6.16G Description .... Wall R-19 2x6 16oc @ GAR Type ........... Wall R-Value ........ 17.8 Hr-sf-F/Btu Framing Material ..... FIR.2X6 Type ......... Wood Description .. 2x6 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 Sketch of Construction Assembly IST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R-Value R-Value 0. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 1. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 2c. BATT.R19 R-19 batt insul (cavity = 5.5 in) 17.80 -- 2f. FIR.2X6 2x6 fir -- 5.45 3. GYP.0.63 0.625 in gypsum or plaster board 0.56 0.56 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R-Values 20.17 7.82 RAMING ADJUSTMENT CALCULATION Cavity Framing Total -Value: (1 / 20.17 x 0.85) + (1 / 7.82 x 0.15) = 0.061 Btu/hr-sf-F otal R-Value: 1 / 0.061 = 16.30 hr-sf-F/Btu )NSTRUCTION ASSEMBLY Page 3 3R rct Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM 3R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Parallel Path Method Reference Name . R.38.2X4.24 Description .... Roof R-38 2x4 24oc Type ........... Roof R-Value ........ 38 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type ......... Wood Description .. 2x4 fir Spacing ...... 24 inches on center Framing Frac.. 0.07 Sketch of Construction Assembly IST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R-Value R-Value D. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.ASPHLT Asphault shingle roofing 0.44 0.44 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5. BATT.R27.0 R-27 batt insulation 27.00 27.00 6c. BATT.R11.0 R-11 batt insul (cavity > 3.5 in) 11.00 -- 6f. FIR.2X4 2x4 fir -- 3.46 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R-Values 41.15 33.62 RAMING ADJUSTMENT CALCULATION Cavity Framing Total -Value: (1 / 41.15 x 0.93) + (1 / 33.62 x 0.07) _ 0.025 Btu/hr-sf-F otal R-Value: 1 / 0.025 = 40.51 hr-sf-F/Btu Plan 1 �RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R pct Title.......... Heritage, Plan 1B Date........ 03/17/99 ,tct Address........ The Heritage Collection ******* La Quinta, CA *v4.50* )cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit # Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date .imate Zone..... ..... 15 )mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Conditioned Floor Area..... 2655 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... 1 Number of Stories. ........ 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 26.9 % of floor area Average Glazing U-value.... 0.6 Btu/hr-sf-F BUILDING SHELL INSULATION nent Frame Cavity Sheathing Insul Assembly 1 pe Type R-value R-value R-value U-value Location/Comments 9.11 Wood R-17.8 R-0 R-17.8 0.061 To Garage all Wood R-17.8 R-4.68 R-22.48 0.049 Hof Wood R-11 R-27 R-38 0.025 R-38 Attic nor n/a R-0 R-n/a R-0 0.330 Solid Wood labEdge n/a R-0 R-n/a R-0 0.900 To Outside labEdge n/a R-0 R-n/a R-0 0.720 To Outside labEdge n/a R-0 R-n/a R-0 0.500 To Garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing rientation (sf) Value es Description Shading Fins Type oor Front (N) 28.0 0.550 2 None None None Wood indow Front (N) 4.8 0.720 2 None None None Metal indow Front (N) 25.0 0.600 2 None None None Metal indow Left (E) 49.0 0.600 2 None None Yes Metal indow Left (E) 6.7 0.430 2 None None Yes Metal indow Left (E) 57.0 0.670 2 None None Yes Metal oor Back (S) 96.0 0.580 2 None None Yes Metal indow Back (S) 133.0 0.670 2 None None Yes Metal oor Back (S) 160.0 0.530 2 None None Yes Metal indow Right (W) 66.5 0.670 2 None None Yes Metal ow Right (W) 35.0 0.430 2 None None Yes Metal w Right (W) 50.0 0.600 2 None None Yes Metal k light Horz 4.0 0.800 2 None None None Metal RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R rct Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Type Exposed THERMAL MASS Area Thickness (sf) (in) Location/Comments SlabOnGrade Yes 241 3.5 SlabOnGrade Yes 114 3.5 SlabOnGrade No 945 3.5 SlabOnGrade No 1355 3.5 HVAC SYSTEMS Minimum Duct Equipment Type Efficiency Location Furnace 0.800 AFUE Attic ACSplit 12.00 SEER Attic Furnace 0.800 AFUE Attic ACSplit 12.00 SEER Attic Entry,Kitch,Hearth,WetBa Baths,Laundry Covered Covered Duct R-value R-4.2 R-4.2 R-4.2 R-4.2 WATER HEATING SYSTEMS Number in lank Type Heater Type Distribution Type System Storage Gas Recirc/TimeTemp 1 SPECIAL FEATURES/REMARKS Thermostat Type LivingStat LivinVtat SleepingStat SleepingStat Tank External Energy Size Insulation Factor (gal) R-value .52 EF 75 R-12 his is a multiple orientation building with no orientation restrictions. his printout is for the front facing North. RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R _Nct Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... John Moore, Sr. Vice Pres Name.... Company. Brookfield Homes Company. Address. 12865 Pointe Del Mar, 200 Address. Del Mar, CA 92014 Phone... 619-481-8500 Phone... License. _�Lak, Signed.. OA t r 141W Signed.. FORCEMENT AGENCY Name.... Title... Agency.. Phone.. Signed. date DOCUMENTATION AUTHOR Beth Brummitt, CEM, CEA Haynal and Company, Inc. 425 W 5th Ave Ste 201 Escondido, CA 92025 760- 43-5408 ate Certified Energy Analyst Beth BrummH NR 92-93-6G6 r r rr R 92-93-213 �CADEC i,-Coldornn Assodoflon of Duilding Energy Conwlron , I - MPUTER METHOD SUMMARY Page 1 C-2R ct Title.......... Heritage, Plan 1B Date........ 03/17/99 �ct Address........ The Heritage Collection ******* La Quinta, CA *v4.50* cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit # Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field Check Date imate Zone........... 15 )mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.36 2.18 0.18 Space Cooling.......... 29.05 25.31 3.74 Water Heating.......... 9.84 9.50 0.34 North Total 41.25 36.99 4.26 Space Heating.......... 2.36 2.86 -0.50 Space Cooling.......... 29.05 25.24 3.81 Water Heating.......... 9.84 9.50 0.34 East Total 41.25 37.60 3.65 Space Heating.......... 2.36 3.06 -0.70 Space Cooling.......... 29.05 25.18 3.87 Water Heating.......... 9.84 9.50 0.34 South Total 41.25 37.74 3.51 Space Heating.......... 2.36 2.12 0.24 Space Cooling.......... 29.05 26.13 2.92 Water Heating.......... 9.84 9.50 0.34 West Total 41.25 37.75 3.50 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... 2655 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 )MPUTER METHOD SUMMARY Page 2 C-2R rct Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Conditioned Volume......... 28646 cf Footprint Area ............. 2655 sf Ground Floor Area.......... 2655 sf Slab -On -Grade Area......... 2655 sf Glazing Percentage......... 26.9 % of floor area Average Glazing U-value.... 0.6 Btu/hr-sf-F Average Ceiling Height..... 10.8 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Dne Type (sf) (cf) Units itioned Type (ft) (sf) IVING Residence 1186 13956 0.45 Yes LivingStat 4.6 n/a LEEPING Residence 1469 14690 0.55 Yes SleepingStat 3.1 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ urface (sf) value R-val Azm Tilt Gains Reference Comments G 5 all 188 0.049 22.48 0 90 Yes W.19.2X6.16F 6 Wall 45 0.049 22.48 90 90 Yes W.19.2X6.16F 7 Wall 115 0.049 22.48 180 90 Yes W.19.2X6.16F 8 Wall 367 0.049 22.48 270 90 Yes W.19.2X6.16F 0 Roof 1186 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic LEEPING 1 Wall 314 0.061 17.8 0 90 No W.19.2X6.16G To Garage 2 Wall 514 0.049 22.48 90 90 Yes W.19.2X6.16F 3 Wall 104 0.049 22.48 180 90 Yes W.19.2X6.16F 4 Wall 210 0.049 22.48 270 90 Yes W.19.2X6.16F 9 Roof 1465 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 1 Door 21 0.330 0 0 90 No None Solid Wood PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVING 12 SlabEdge 5 0.900 R-0 No To Outside 14 SlabEdge 97 0.720 R-0 No To Outside SLEEPING 13 SlabEdge 103 0.720 R-0 No To Outside 15 SlabEdge 34 0.500 R-0 No To Garage )MPUTER METHOD SUMMARY Page 3 C-2R 'Pct Title.......... Heritage, Plan 13 Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM User#-MP1657 User-Haynal and Company, Inc. Run -Typical C-2R House FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ irface (sf) es Type Type value Azm Tlt Only Shade Description IVING 1 Door 28.0 2 Wood Std 0.550 0 90 0.88 0.78 None 2 Window 4.8 2 Metal Std 0.720 0 90 0.88 0.78 None 3 Window 25.0 2 Metal Std 0.600 0 90 0.47 0.78 None 8 Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None 9 Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None 1 Window 76.0 2 Metal Std 0.670 180 90 0.66 0.78 None 2 Window 28.5 2 Metal Std 0.670 180 90 0.66 0.78 None 3 Window 28.5 2 Metal Std 0.670 180 90 0.66 0.78 None 4 Door 80.0 2 Metal Std 0.530 180 90 0.66 0.78 None 5 Door 80.0 2 Metal Std 0.530 180 90 0.66 0.78 None 6 Window 28.5 2 Metal Std 0.670 270 90 0.66 0.78 None 7 Window 38.0 2 Metal Std 0.670 270 90 0.66 0.78 None 8 Window 35.0 2 Metal Std 0.430 270 90 0.47 0.78 None LEEPING 4 Window 9.0 2 Metal Std 0.600 90 90 0.47 0.78 None c7 'yindow 30.0 2 Metal Std 0.600 90 90 0.47 0.78 None �i.ndow 6.7 2 Metal Std 0.430 90 90 0.47 0.78 None 7 Oindow 10.0 2 Metal Std 0.600 90 90 0.47 0.78 None 0 Door 96.0 2 Metal Std 0.580 180 90 0.47 0.78 None 9 Window 30.0 2 Metal Std 0.600 270 90 0.47 0.78 None 0 Window 20.0 2 Metal Std 0.600 270 90 0.47 0.78 None 1 Skylight 4.0 2 Metal Std 0.800 0 0 0.72 1.00 None OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght urface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght IVING 8 Window 28.5 9.5 3 1.5 0.5 11 .5 n/a n/a n/a .5 20 1.5 9 Window 28.5 9.5 3 19 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 1 Window 76.0 9.5 8 11 .5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 28.5 9.5 3 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 28.5 9.5 3 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 80.0 10 8 11 .5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 80.0 10 8 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 28.5 9.5 3 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 38.0 9.5 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 35.0 7 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a LEEPING 4 Window 9.0 2 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 30.0 5 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a r Window 6.7 5 1.33 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 10.0 2 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 0 600r 96.0 8 12 3 .5 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 30.0 5 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 0 Window 20.0 5 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a )MPUTER METHOD SUMMARY Page 4 C-2R '"Nct Title.......... Heritage, Plan 1B Date........ 03/17/99 MICROPAS4 v4.50 File-HERITI Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House THERMAL MASS Area Thick Heat Conduct- Surface 3.ss Type (sf) (in) Cap ivity R-value Location/Comments IVING L S1abOnGrade 241 3.5 28.0 0.98 R-0.0 3 S1abOnGrade 945 3.5 28.0 0.98 R-2.0 =PING 2 S1abOnGrade 114 3.5 28.0 0.98 R-0.0 I SlabOnGrade 1355 3.5 28.0 0.98 R-2.0 HVAC SYSTEMS Minimum Duct System Type Efficiency Location LIVING Furnace ACSplit SLEEPING Furnace ACSplit rank Type Heater Type 1 Storage Gas 0.800 AFUE Attic 12.00 SEER Attic 0.800 AFUE Attic 12.00 SEER Attic WATER HEATING SYSTEMS Number in Distribution Type System Recirc/TimeTemp 1 SPECIAL FEATURES/REMARKS Entry,Kitch,Hearth,WetBar Covered Baths,Laundry Covered Duct Duct R-value Efficiency R-4.2 R-4.2 R-4.2 R-4.2 Energy Factor .52 0.830 0.810 0.830 0.810 Tank Size (gal) 75 External Insulation R-value R-12 his is a multiple orientation building with no orientation restrictions. his printout is for the front facing North. Calculation for Ventilation Height Heritage: Plan 1 Gross Weighted Opening Gross Effective Vent Vent Area Horizontal Center Vent Area * Average Height Area % Area Inlet Outlet Inlet Outlet Height Height Height SLEEPING ZONE: Sliding windows/doors 0.1 0 0 0 4620 2 9 0.1 0.9 0.45 0.45 0.5 1.5 1 9 3050 5 15 0.1 1.5 0.75 0.75 1.25 3.75 2.5 37.5 3050 5 15 0.1 1.5 0.75 0.75 1.25 3.75 2.5 37.5 5020 2 10 0.1 1 0.5 0.5 0.5 1.5 1 10 12080 8 96 0.1 9.6 4.8 4.8 2 6 4 384 6050 5 30 0.1 3 1.5 1.5 1.25 3.75 2.5 75 4050 5 20 0.1 2 1 1 1.25 3.75 2.5 50 Hinged windows/doors 0 0.2 0 0 0 0 0 0 0 none Total Operable 195 19.5 9.75 9.75 6031 3.1 Fixed windows 0 0 1450 0 6.65 Total Sleeping 201.65 i LIVING ZONE: Sliding windows/doors 0.1 0 0 0 80100 10 80 0.1 8 4 4 2.5 7.5 5 400 80100 10 80 0.1 8 4 4 2.5 7.5 5 400 5050 5 25 0.1 2.5 1.25 1.25 1.25 3.75 2.5 62.5 Hinged windows/doors 0 0.2 0 0 0 0 0 0 0 3680 8 28 0.2 5.6 2.8 2.8 2 6 4 112 Total Operable 213 24.1 12.05 12.05 974.5 4.6 Fixed windows 0.0 0 5(3096) n/a 142.5 8096 n/a 76.0 4096 n/a 38.0 5070 n/a 35.0 36-1/2Round n/a 4.8 Total Living 509.3 TOTAL Fenestration 711.0 heritage cr / Vent Height Pln 1 3/19/99 Plan 1 with Guest 2 RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R 'iect Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 ,hct Address........ The Heritage Collection ******* La Quinta, CA *v4.50* )cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date .imate Zone. ........ 15 )mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERITIG2 Wth-CTZ15S92 Program -FORM CF-1R I User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Anent ¢pe GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories. ........ Floor Construction Type.... Glazing Percentage......... Average Glazing U-value.... Frame Type 3091 sf Single Family Detached New Cardinal - N,E,S,W 1 1 Slab On Grade An % of floor area 0.59 Btu/hr-sf-F BUILDING SHELL INSULATION Cavity Sheathing Insul Assembly R-value R-value R-value U-value Location/Comments all Wood R-17.8 R-0 R-17.8 0.061 To Garage all Wood R-17.8 R-4.68 R-22.48 0.049 Dof Wood R-11 R-27 R-38 0.025 R-38 Attic oor n/a R-0 R-n/a R-0 0.330 Solid Wood labEdge n/a R-0 R-n/a R-0 0.900 To Outside labEdge n/a R-0 R-n/a R-0 0.720 To Outside labEdge n/a R-0 R-n/a R-0 0.500 To Garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing rientation (sf) Value es Description Shading Fins Type oor Front (N) 28.0 0.550 2 None None None Wood indow Front (N) 4.8 0.720 2 None None None Metal indow Front (N) 25.0 0.600 2 None None None Metal indow Left (E) 49.0 0.600 2 None None Yes Metal indow Left (E) 6.7 0.430 2 None None Yes Metal indow Left (E) 57.0 0.670 2 None None Yes Metal oor Back (S) 96.0 0.580 2 None None Yes Metal indow Back (S) 133.0 0.670 2 None None Yes Metal oor Back (S) 160.0 0.530 2 None None Yes Metal indow Right (W) 66.5 0.670 2 None None Yes Metal 'indow Right (W) 35.0 0.430 2 None None Yes Metal bw Right (W) 50.0 0.600 2 None None Yes Metal �...Jow Left (E) 6.0 0.570 2 None None None None 'indow Left (E) 8.0 0.430 2 None None None Metal loor Back (S) 45.0 0.580 2 None None None Metal t2TIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R �!,ect Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 T MICROPAS4 v4.50 File-HERITIG2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing ientation (sf) Value es Description Shading Fins Type ndow Right (W) 6.0 0.600 2 None None None Metal ylight Horz 4.0 0.800 2 None None None Metal THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments SlabOnGrade Yes 241 3.5 Entry,Kitch,Hearth,WetBa SlabOnGrade Yes 114 3.5 Baths,Laundry SlabOnGrade No 945 3.5 Covered SlabOnGrade No 1355 3.5 Covered SlabOnGrade No 436 3.5 Covered HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic R-4.2 LivingStat ACSplit 12.00 SEER Attic R-4.2 LivingStat Furnace 0.800 AFUE Attic R-4.2 SleepingStat ACSplit 12.00 SEER Attic R-4.2 SleepingStat Furnace 0.800 AFUE Attic R-4.2 SleepingStat ACSplit 12.00 SEER Attic R-4.2 SleepingStat WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Cank Type Heater Type Distribution Type System Factor (gal) R-value Storage Gas Recirc/TimeTemp 1 .52 EF 75 R-12 SPECIAL FEATURES/REMARKS As is a multiple orientation building with no orientation restrictions. its printout is for the front facing North. I RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R -erect Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT1G2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. Name.... Company. Address. Phone.. License Signed Name.. Title. Agency.. Phone... DESIGNER or OWNER John Moore, Sr. Vice Pres Brookfield Homes 12865 Pointe Del Mar, 200 Del Mar, CA 92014 619-481-8500 Signed.. date DOCUMENTATION AUTHOR Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. Address. 425 W 5th Ave Ste 201 Escondido, CA 92025 Phone... 760-743-5408 Signed.. date MPUTER METHOD SUMMARY Page 1 C-2R P4,,�_ct Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 ******* ct Address........ The Heritage Collection La Quinta, CA *v4.50* cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date imate Zone..... ..... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT1G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.78 2.43 0.35 Space Cooling.......... 30.02 24.69 5.33 Water Heating.......... 8.45 8.16 0.29 North Total 41.25 35.28 5.97 Space Heating.......... 2.78 3.11 -0.33 Space Cooling.......... 30.02 24.68 5.34 Water Heating.......... 8.45 8.16 0.29 East Total 41.25 35.95 5.30 Space Heating.......... 2.78 3.41 -0.63 Space Cooling.......... 30.02 24.41 5.61 Water Heating.......... 8.45 8.16 0.29 South Total 41.25 35.98 5.27 Space Heating.......... 2.78 2.51 0.27 Space Cooling.......... 30.02 25.36 4.66 Water Heating.......... 8.45 8.16 0.29 West Total 41.25 36.03 5.22 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3091 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 DMPUTER METHOD SUMMARY Page 2 C-2R Vct Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERITIG2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House one Type IVING Residence LEEPING Residence UEST Residence dace IVING 5 Wall 6 Wall 7 Wall 8 Wall 4 Roof LEEPING 1 Wall 2 Wall 3 Wall 4 Wall 3 Roof 6 Door UEST 9 Wall 0 Wall 1 Wall 2 Wall 5 Roof Conditioned Volume......... 32570 cf Footprint Area ............. 3091 sf Ground Floor Area.......... 3091 sf Slab -On -Grade Area......... 3091 sf Glazing Percentage......... 25.2 % of floor area Average Glazing U-value.... 0.59 Btu/hr-sf-F Average Ceiling Height..... 10.5 ft BUILDING ZONE INFORMATION Floor Area Volume (sf) (cf) # of Dwell Cond- Thermostat Units itioned Type Vent Special Height Vent Area (ft) (sf) 1186 13956 0.38 Yes LivingStat 4.6 n/a 1469 14690 0.48 Yes SleepingStat 3.1 n/a 436 3924 0.14 Yes SleepingStat 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ (sf) value R-val Azm Tilt Gains Reference Comments 188 0.049 22.48 0 90 Yes W.19.2X6.16F 45 0.049 22.48 90 90 Yes W.19.2X6.16F 115 0.049 22.48 180 90 Yes W.19.2X6.16F 367 0.049 22.48 270 90 Yes W.19.2X6.16F 1186 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 314 0.061 17.8 0 90 No W.19.2X6.16G To Garage 514 0.049 22.48 90 90 Yes W.19.2X6.16F 104 0.049 22.48 180 90 Yes W.19.2X6.16F 210 0.049 22.48 270 90 Yes W.19.2X6.16F 1465 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 21 0.330 0 0 90 No None Solid Wood 153 0.049 22.48 0 90 Yes W.19.2X6.16F 220 0.049 22.48 90 90 Yes W.19.2X6.16F 108 0.049 22.48 180 90 Yes W.19.2X6.16F 228 0.049 22.48 270 90 Yes W.19.2X6.16F 436 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVING 17 SlabEdge 5 0.900 R-0 No To Outside 19 SlabEdge 97 0.720 R-0 No To Outside SLEEPING 18 SlabEdge 103 0.720 R-0 No To Outside MPUTER METHOD SUMMARY Page 3 C-2R ­4ect Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT1G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments 20 SlabEdge 34 0.500 R-0 No To Garage GUEST 21 SlabEdge 76 0.720 R-0 No To Outside 22 SlabEdge 10 0.900 R-0 No To Outside FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Lrface (sf) es Type Type value Azm Tlt Only Shade Description :VING Door 28.0 2 Wood Std 0.550 0 90 0.88 0.78 None Window 4.8 2 Metal Std 0.720 0 90 0.88 0.78 None Window 25.0 2 Metal Std 0.600 0 90 0.47 0.78 None I Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None Window 76.0 2 Metal Std 0.670 180 90 0.66 0.78 None ndow 28.5 2 Metal Std 0.670 180 90 0.66 0.78 None Window 28.5 2 Metal Std 0.670 180 90 0.66 0.78 None 6 Door 80.0 2 Metal Std 0.530 180 90 0.66 0.78 None i Door 80.0 2 Metal Std 0.530 180 90 0.66 0.78 None i Window 28.5 2 Metal Std 0.670 270 90 0.66 0.78 None Window 38.0 2 Metal Std 0.670 270 90 0.66 0.78 None 3 Window 35.0 2 Metal Std 0.430 270 90 0.47 0.78 None .jEEPING 6 Window 9.0 2 Metal Std 0.600 90 90 0.47 0.78 None i Window 30.0 2 Metal Std 0.600 90 90 0.47 0.78 None i Window 6.7 2 Metal Std 0.430 90 90 0.47 0.78 None 7 Window 10.0 2 Metal Std 0.600 90 90 0.47 0.78 None ) Door 96.0 2 Metal Std 0.580 180 90 0.47 0.78 None ) Window 30.0 2 Metal Std 0.600 270 90 0.47 0.78 None ) Window 20.0 2 Metal Std 0.600 270 90 0.47 0.78 None i Skylight 4.0 2 Metal Std 0.800 0 0 0.72 1.00 None JEST L Window 6.0 2 None Std 0.570 90 90 0.88 0.78 None ? Window 8.0 2 Metal Std 0.430 90 90 0.47 0.78 None 3 Door 45.0 2 Metal Std 0.580 180 90 0.47 0.78 None I Window 6.0 2 Metal Std 0.600 270 90 0.47 0.78 None OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght zrface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght �IG endow 28.5 9.5 3 1.5 0.5 11 .5 n/a n/a n/a .5 20 1.5 a Window 28.5 9.5 3 19 0.5 n/a n/a n/a n/a n/a n/a n/a n/a L Window 76.0 9.5 8 11 .5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 28.5 9.5 3 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a )MPUTER METHOD SUMMARY Page 4 C-2R ;,ect Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERITIG2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght .1rface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght 3 Window 28.5 9.5 3 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 80.0 10 8 11 .5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 80.0 10 8 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 28.5 9.5 3 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 38.0 9.5 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a B Window 35.0 7 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a LEEPING 4 Window 9.0 2 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 30.0 5 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 6.7 5 1.33 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 10.0 2 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 0 Door 96.0 8 12 3 .5 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 30.0 5 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 0 Window 20.0 5 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface Type (sf) (in) Cap ivity R-value Location/Comments IVING 1 S1abOnGrade 241 3.5 28.0 0.98 R-0.0 Entry,Kitch,Hearth,WetBar 3 S1abOnGrade 945 3.5 28.0 0.98 R-2.0 Covered LEEPING 2 S1abOnGrade 114 3.5 28.0 0.98 R-0.0 Baths,Laundry 4 S1abOnGrade 1355 3.5 28.0 0.98 R-2.0 Covered UEST 5 S1abOnGrade 436 3.5 28.0 0.98 R-2.0 Covered System Type LIVING Furnace ACSplit SLEEPING Furnace ACSplit GUEST Furnace ACSplit HVAC SYSTEMS Minimum Efficiency Duct Duct Duct Location R-value Efficiency 0.800 AFUE Attic R-4.2 0.830 12.00 SEER Attic R-4.2 0.810 0.800 AFUE Attic R-4.2 0.830 12.00 SEER Attic R-4.2 0.810 0.800 AFUE Attic R-4.2 0.830 12.00 SEER Attic R-4.2 0.810 MPUTER METHOD SUMMARY Page 5 C-2R erect Title.......... Heritage, Plan 1B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERITIG2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House 'ank Type 1 Storage WATER HEATING SYSTEMS Number Tank in Energy Size Heater Type Distribution Type System Factor (gal) Gas Recirc/TimeTemp 1 .52 75 SPECIAL FEATURES/REMARKS External Insulation R-value R-12 Lis is a multiple orientation building with no orientation restrictions. Lis printout is for the front facing North. Plan 1 with Guest 3 J ;RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R ^iect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 ******* ct Address........ The Heritage Collection La Quinta, CA *v4.50* )cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date .imate Zone..... ..... 15 )mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories. ...... Floor Construction Type.... Glazing Percentage......... Average Glazing U-value.... 3259 sf Single Family Detached New Cardinal - N,E,S,W 1 1 Slab On Grade 24.9 % of floor area 0.59 Btu/hr-sf-F BUILDING SHELL INSULATION anent Frame Cavity Sheathing Insul Assembly ,fie Type R-value R-value R-value U-value Location/Comments ill Wood R-17.8 R-0 R-17.8 0.061 To Garage ill Wood R-17.8 R-4.68 R-22.48 0.049 )of Wood R-11 R-27 R-38 0.025 R-38 Attic )or n/a R-0 R-n/a R-0 0.330 Solid Wood LabEdge n/a R-0 R-n/a R-0 0.900 To Outside LabEdge n/a R-0 R-n/a R-0 0.720 To Outside LabEdge n/a R-0 R-n/a R-0 0.500 To Garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing :ientation (sf) value es Description Shading Fins Type )or Front (N) 28.0 0.550 2 None None None Wood Lndow Front (N) 4.8 0.720 2 None None None Metal Lndow Front (N) 55.0 0.600 2 None None None Metal Lndow Left (E) 49.0 0.600 2 None None Yes Metal Lndow Left (E) 6.7 0.430 2 None None Yes Metal Lndow Left (E) 57.0 0.670 2 None None Yes Metal )or Back (S) 96.0 0.580 2 None None Yes Metal Lndow Back (S) 133.0 0.670 2 None None Yes Metal )or Back (S) 160.0 0.530 2 None None Yes Metal Lndow Right (W) 66.5 0.670 2 None None Yes Metal Lndow Right (W) 35.0 0.430 2 None None Yes Metal ' w Right (W) 50.0 0.600 2 None None Yes Metal Lw Front (N) 4.5 0.430 2 None None None Metal Lndow Left (E) 8.0 0.430 2 None None None Metal nor Back (S) 45.0 0.580 2 None None None Metal ERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R r� ect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House rientation indow Right (W) kylight Horz Type FENESTRATION # of Interior Area U- Pan- Shading/ (sf) Value es Description 8.0 0.430 2 None 4.0 0.800 2 None THERMAL MASS Exposed S1abOnGrade Yes S1abOnGrade Yes S1abOnGrade No S1abOnGrade No S1abOnGrade No S1abOnGrade Yes Area Thickness Over - Exterior hang/ Framing Shading Fins Type None None Metal None None Metal (sf) (in) Location/Comments 241 3.5 Entry,Kitch,Hearth,WetBa 114 3.5 Baths,Laundry 945 3.5 Covered 1355 3.5 Covered 386 3.5 Covered 50 3.5 Bath HVAC SYSTEMS Minimum Duct Duct Equipment Type Efficiency Location R-value Furnace ACSplit Furnace ACSplit Furnace ACSplit Tank Type I 0.800 AFUE Attic R-4.2 12.00 SEER Attic R-4.2 0.800 AFUE Attic R-4.2 12.00 SEER Attic R-4.2 0.800 AFUE Attic R-4.2 12.00 SEER Attic R-4.2 WATER HEATING SYSTEMS Number in Heater Type Distribution Type System Thermostat Type Setback Setback Setback Setback Setback Setback Tank External Energy Size Insulation Factor (gal) R-value Storage Gas Recirc/TimeTemp 1 .52 EF 75 R-12 DHW2 Storage Gas Standard 1 .535 EF 40 R-12 SPECIAL FEATURES/REMARKS 'his is a multiple orientation building with no orientation restrictions. 'his printout is for the front facing North. RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R '­�ct Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. Name.... Company. Address. Phone... License. S ignec Name..`' Title... Agency.. Phone... DESIGNER or OWNER John Moore, Sr. Vice Pres Brookfield Homes 12865 Pointe Del Mar, 200 Del Mar, CA 92014 619-481-8500 Signed.. date DOCUMENTATION AUTHOR Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. Address. 425 W 5th Ave Ste 201 Escondido, CA 92025 Phone... 760-743-5408 99ACSigned.. J 1 dat iMPUTER METHOD SUMMARY Page 1 C-2R •-iect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 ject Address........ The Heritage Collection ******* La Quinta, CA *v4.50* )cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit if Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date .imate Zone........... 15 >mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.85 2.54 0.31 Space Cooling.......... 30.14 27.35 2.79 Water Heating.......... 8.02 9.87 -1.85 North Total 41.01 39.76 1.25 Space Heating.......... 2.85 3.19 -0.34 Space Cooling.......... 30.14 27.51 2.63 Water Heating.......... 8.02 9.87 -1.85 East Total 41.01 40.57 0.44 Space Heating.......... 2.85 3.34 -0.49 Space Cooling.......... 30.14 26.99 3.15 Water Heating.......... 8.02 9.87 -1.85 South Total 41.01 40.20 0.81 Space Heating.......... 2.85 2.58 0.27 Space Cooling.......... 30.14 28.28 1.86 Water Heating.......... 8.02 9.87 -1.85 West Total 41.01 40.73 0.28 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3259 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 KPUTER METHOD SUMMARY Page 2 C-2R --sect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT1G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ne Type VING .esidence ,EEPING .esidence [EST .esidence Conditioned Volume......... 34082 cf Footprint Area ............. 3091 sf Ground Floor Area.......... 3091 sf Slab -On -Grade Area......... 3091 sf Glazing Percentage......... 24.9 % of floor area Average Glazing U-value.... 0.59 Btu/hr-sf-F Average Ceiling Height..... 10.5 ft BUILDING ZONE INFORMATION Floor Area Volume (sf) (cf) 1186 1469 604 Area ce (sf) :VING > Wall 188 i Wall 45 Wall 115 3 Wall 367 6 Roof 1186 .jEEPING L Wall 314 ? Wall 514 3 Wall 104 1 Wall 210 3 Roof 1465 5 Door 21 JEST Wall 155 J Wall 289 L Wall 144 2 Wall 289 5 Roof 604 Surface LIVING 17 S1abEdge 19 S1abEdge SLEEPING 18 S1abEdge # of Dwell Cond- Thermostat Units itioned Type Vent Special Height Vent Area (ft) (sf) 13956 0.36 Yes Setback 4.6 n/a 14690 0.45 Yes Setback 3.1 n/a 5436 0.19 Yes Setback 2.0 n/a OPAQUE SURFACES U- Insul Act Solar Form 3 Location/ value R-val Azm Tilt Gains Reference Comments 0.049 22.48 0 90 Yes W.19.2X6.16F 0.049 22.48 90 90 Yes W.19.2X6.16F 0.049 22.48 180 90 Yes W.19.2X6.16F 0.049 22.48 270 90 Yes W.19.2X6.16F 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 0.061 17.8 0 90 No W.19.2X6.16G To Garage 0.049 22.48 90 90 Yes W.19.2X6.16F 0.049 22.48 180 90 Yes W.19.2X6.16F 0.049 22.48 270 90 Yes W.19.2X6.16F 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 0.330 0 0 90 No None Solid Wood 0.049 22.48 0 90 Yes W.19.2X6.16F 0.049 22.48 90 90 Yes W.19.2X6.16F 0.049 22.48 180 90 Yes W.19.2X6.16F 0.049 22.48 270 90 Yes W.19.2X6.16F 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 5 0.900 R-0 No To Outside 97 0.720 R-0 No To Outside 103 0.720 R-0 No To Outside )MPUTER METHOD SUMMARY Page 3 C-2R r-iect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments 20 S1abEdge 34 0.500 R-0 No To Garage GUEST 21 SlabEdge 108 0.720 R-0 No To Outside FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ urface (sf) es Type Type value Azm Tlt Only Shade Description IVING 1 Door 28.0 2 Wood Std 0.550 0 90 0.88 0.78 None 2 Window 4.8 2 Metal Std 0.720 0 90 0.88 0.78 None 3 Window 25.0 2 Metal Std 0.600 0 90 0.47 0.78 None 8 Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None 9 Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None 1 Window 76.0 2 Metal Std 0.670 180 90 0.66 0.78 None 2 Window 28.5 2 Metal Std 0.670 180 90 0.66 0.78 None -iindow 28.5 2 Metal Std 0.670 180 90 0.66 0.78 None poor 80.0 2 Metal Std 0.530 180 90 0.66 0.78 None 5 Door 80.0 2 Metal Std 0.530 180 90 0.66 0.78 None 6 Window 28.5 2 Metal Std 0.670 270 90 0.66 0.78 None 7 Window 38.0 2 Metal Std 0.670 270 90 0.66 0.78 None 8 Window 35.0 2 Metal Std 0.430 270 90 0.47 0.78 None LEEPING 4 Window 9.0 2 Metal Std 0.600 90 90 0.47 0.78 None 5 Window 30.0 2 Metal Std 0.600 90 90 0.47 0.78 None 6 Window 6.7 2 Metal Std 0.430 90 90 0.47 0.78 None 7 Window 10.0 2 Metal Std 0.600 90 90 0.47 0.78 None 0 Door 96.0 2 Metal Std 0.580 180 90 0.47 0.78 None 9 Window 30.0 2 Metal Std 0.600 270 90 0.47 0.78 None 0 Window 20.0 2 Metal Std 0.600 270 90 0.47 0.78 None 6 Skylight 4.0 2 Metal Std 0.800 0 0 0.72 1.00 None UEST 1 Window 30.0 2 Metal Std 0.600 0 90 0.47 0.78 None 2 Window 4.5 2 Metal Std 0.430 0 90 0.47 0.78 None 3 Window 8.0 2 Metal Std 0.430 90 90 0.47 0.78 None 4 Door 45.0 2 Metal Std 0.580 180 90 0.47 0.78 None 5 Window 8.0 2 Metal Std 0.430 270 90 0.47 0.78 None OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght urface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght . indow 28.5 9.5 3 1.5 0.5 11 .5 n/a n/a n/a .5 20 1.5 9 Window 28.5 9.5 3 19 0.5 n/a n/a n/a n/a n/a n/a n/a n/a .1 Window 76.0 9.5 8 11 .5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 28.5 9.5 3 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a iMPUTER METHOD SUMMARY Page 4 C-2R ­i-ct Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght irface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght Window 28.5 9.5 3 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a Door 80.0 10 8 11 .5 n/a n/a n/a n/a n/a n/a n/a n/a Door 80.0 10 8 6 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 28.5 9.5 3 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 38.0 9.5 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a { Window 35.0 7 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a jEEPING 6 Window 9.0 2 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a > Window 30.0 5 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 6.7 5 1.33 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 10.0 2 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Door 96.0 8 12 3 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 30.0 5 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 20.0 5 4 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface Type (sf) (in) Cap ivity R-value Location/Comments CVING L SlabOnGrade 241 3.5 28.0 0.98 R-0.0 Entry,Kitch,Hearth,WetBar 3 SlabOnGrade 945 3.5 28.0 0.98 R-2.0 Covered .,EEPING SlabOnGrade 114 3.5 28.0 0.98 R-0.0 Baths,Laundry 6 SlabOnGrade 1355 3.5 28.0 0.98 R-2.0 Covered JEST i SlabOnGrade 386 3.5 28.0 0.98 R-2.0 Covered i SlabOnGrade 50 3.5 28.0 0.98 R-0.0 Bath HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 SLEEPING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 GUEST Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 OMPUTER METHOD SUMMARY Page 5 C-2R r-I,ect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Tank Type DHW1 1 Storage DHW2 2 Storage WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R-value Gas Recirc/TimeTemp 1 .52 75 R-12 Gas Standard 1 .535 40 R-12 SPECIAL FEATURES/REMARKS 'his is a multiple orientation building with no orientation restrictions. 'his printout is for the front facing North. Plan 1 HVAC Loads Page 1 HVAC n-) /9 4 /QQ J 1u11vv Plan 1B,ction Guest3Date........ ect Title.......... Heritage, ******* ect Address........ The Heritage Colle*v4.50* La Quinta, CA ******* Building Permit # mentation Author... Beth Brumn[litt, CEM, CEA Haynal and Company, Inc. �—Fi an Chec Date 425 W 5th Ave Ste 201 Escondido, CA 92025 eC ec Date 760-743-5408 p Inc. [late Zone........... 15 y Enercom , nncrhnd_ ..... MICROPAS4 v4.50 for 1995 Standards .. ^Tw7T*Tr MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program MICROPAS4 MD1Gri% User-Haynal and Company, Inc. Run -'Typical House GENERAL INFORMATION 3259 sf Floor Area ................. 34082 cf Volume ...........••••• .... Front Facing 0 deg (N) Front Orientation .......... PALM DESERT Sizing Location ............ 33.7 degrees Latitude .••••.. Design. 32 F Winter Outside 70 F Winter Inside Design10 F Summer Outside Design ...... 11 F Summer Inside Design..•••' 34 F Summer Range .............. Used. No Interior Shading Used...... No Exterior Shading Used...... Yes Overhang Shading Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Description 9387 opaque Conduction and Solar.. p 17746 18225 17746 Glazing Conduction. ......• ..'' .. ' n/a 13632 Glazing Solar............• ...... 17997 13574 Infiltration .............••• n/a 2597 Internal Gain ................... 5397 5694 Ducts ...................... 59366 62629 Sensible Load .................... 18789 n/a Latent Load ...................... 81417 'mum Total Load 59366 Mini he criteria affecting the selection Note: The loads shown are only one of t s coil sizing, availabilitIt Of equipment. Other relevant design factors such as air flow of HVACoutdoor design temperatures, requirements, safety margin, etc., must also be considered. equipment, oversizing to consider all factors when selecting the HVAC designer's responsibility the HVAC equipment. SIZING Heritage, Plan 1B, Guest3 Page 2 HVAC n /� 4 /OQ Date........ =%__ 11v-v. - MICROPAS4 v4.50 File-HERIT1G3 Wth-CTZ15S92 Program- r,.....,.u_MD1 F.9i7 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' 1186 sf . Floor Area ....................... 13956 cf Volume ....................... Heating Cooling (Btuh) (Btuh) Description 5255 2873 0 aque Conduction and Solar...... p 11611 11306 Glazing Conduction .•••••• ...,,,, n/a 8213 Glazing Solar ..............• 7369 5558 Infiltration ............... n/a 981 Internal Gain ................::: 2424 2893 Ducts ........................ 26659 31825 Sensible Load .................... n/a 9547 Latent Load ...................... 41372 Minimum Zone Load 26659 ZONE 'SLEEPING' 1469 sf Floor Area ....................... 14690 cf Volume ....................... Heating Cooling (Btuh) (Btuh) Description 7355 4165 0 aque Conduction and Solar ...... P 4603 4482 Glazing Conduction �� " '.. n/a 4140 Glazing Solar ............•••...,_.. 7757 5851 Infiltration................. n/a 1226 Internal Gain ................::: 1972 1986 Ducts ........................ 21687 21850 Sensible Load .................... 6555 n/a Latent Load ...................... _- 28405 Minimum Zone Load 21687 �C SIZING Page 3 HVAC 1�ect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating (Btuh) Opaque Conduction and Solar...... 5137 Glazing Conduction ............... 2011 Glazing Solar .................... n/a Infiltration ..................... 2870 Internal Gain .................... n/a Ducts ............................ 1002 Sensible Load .................... 11020 Latent Load ...................... n/a Minimum Zone Load 11020 Cooling (Btuh) 2348 1958 1279 2165 390 814 8954 2686 11640 ;IZING Heritage, ct Title ........ • Wth-CTZ15S92 File-HERITIG3 Inc MICROPAS4 v4.50 nal and Company, User#-Mpl657 User -Hay plan 1B, Guest3 GENERAL INFORMATION Floor Area .•• •••••::;::.,, Volume ...... ....••• Front Orientation...,...... Sizing Location.....: Latitude ........ esign.....• Winter outside Winter Inside Design ... Summer Outside Design ...... Summer Inside Design......: Summer Range ............... Interior Shading Used Used ...... Exterior Shading Used ...... Overhang Shading Load Fraction....... Page 4 Date ..... HVAC . 03/18/99 Program-HVAC SIZING Run -Typical House 3259 sf 34082 cf 90 deg (E) Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 Latent COOLING LOAD SUMMARY HEATING AND Cooling Heating (Btuh) ------ Description 17245 9387 Conduction and Solar...... 18225 17746 15509 Opaque Glazing Conduction... .... :::: 13574 ... Glazing Solar..••: .........• 17n/a 9/7 a 2597 Infiltration....••• .... n 5397 5881 Internal Gain .••••••••••...... Ducts ...... ••••..... 59366 64694 Sensible Load,---*--* n/a 19408 Latent Load .••••••••'• 59366 84102 Minimum Total Load cting the selection as air flow ads shown are only one of the crinefactorsesuch of Note: The to Other relevant design availability i ment. eratures, coil sizing, It is of HVAC equ p outdoor design temp must also be CO nsidereSelecting equipment, oversizing safety margin, etc., equipment, designer's responsibility to consider all factors when the HVAC des lgment . the HVAC equ p �C SIZING Page 5 HVAC 4 ect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1186 sf Volume ........................... 13956 cf Heating Description (Btuh) Opaque Conduction and Solar...... 5255 Glazing Conduction ............... 11611 Glazing Solar .................... n/a Infiltration ..................... 7369 Internal Gain .................... n/a Ducts ............................ 2424 Sensible Load .................... 26659 Latent Load ...................... n/a Minimum Zone Load 26659 ZONE 'SLEEPING' Floor Area ....................... 1469 sf Volume ........................... 14690 cf Heating Description (Btuh) Opaque Conduction and Solar...... 7355 Glazing Conduction ............... 4603 Glazing Solar .................... n/a Infiltration ..................... 7757 Internal Gain .................... n/a Ducts ............................ 1972 Sensible Load .................... 21687 Latent Load ...................... n/a Minimum Zone Load 21687 0 Cooling (Btuh) 2873 11306 9591 5558 981 3031 33340 10002 43342 Cooling (Btuh) 4165 4482 3390 5851 1226 1911 21025 6308 27333 ,C SIZING Page 6 HVAC aiect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf 5436 cf Volume ........................... Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 1958 Glazing Conduction ............... 2011 n/a 2529 Glazing Solar .................... Infiltration 2870 2165 ..................... Internal Gain n/a 390 .................... 1002 939 Ducts ............................ Sensible Load .................... 11020 10329 Latent Load ...................... n/a 3099 Minimum Zone Load 11020 13427 Page 7 HVAC SIZING sect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZHouING User#-MP1657 User-Haynal and Company, Inc. Run -Typical GENERAL INFORMATION Floor Area ................. Volume.. ............ Front Orientation.......... Sizing Location............ Latitude... ......•• Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3259 sf 34082 cf Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Total Load 180 deg (S) Heating Cooling (Btuh) (Btuh) 17746 9387 18225 17746 n/a 14103 17997 13574 n/a 2597 5397 5741 59366 63147 n/a 18944 59366 82092 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow Of requirements, outdoor design temperatures, coil sizing, availability d. It is equipment, oversizing safety margin, etc., must also be considere the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. C SIZING Page 8 HVAC 1ect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-dAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run-TypicalHouse HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' 1186 sf Floor Area ....................... Volume 13956 cf ........................... Heating Cooling (Btuh) (Btuh) Description Opaque Conduction and Solar...... 5255 2873 11306 Glazing Conduction ............... 11611 n/a 8757 Glazing Solar .................... 7369 5558 Infiltration ..................... n/a 81 948 Internal Gain .................... Ducts ............................ 2424 29 26659 32424 Sensible Load .................... n/a 9727 Latent Load ...................... Minimum Zone Load 26659 42151 ZONE 'SLEEPING' Floor Area ....................... 1469 sf Volume ........................... 14690 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Zone Load Heating Cooling (Btuh) (Btuh) 7355 4165 4603 4482 n/a 4140 7757 5851 n/a 1226 1972 1986 21687 21850 n/a 6555 21687 28405 C SIZING Page 9 HVAC w-ect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 2011 1958 Glazing Solar .................... n/a 1206 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 390 Ducts ............................ 1002 807 Sensible Load .................... 11020 8873 Latent Load ...................... n/a 2662 Minimum Zone Load 11020 11536 kC SIZING Page 10 HVAC affect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT1G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume .. ..... ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. .... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3259 sf 34082 cf Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 17746 9387 Glazing Conduction ............... 18225 17746 Glazing Solar .................... n/a 15821 Infiltration ..................... 17997 13574 Internal Gain .................... n/a 2597 Ducts ............................ 5397 5912 Sensible Load .................... 59366 65037 Latent Load ...................... n/a 19511 Minimum Total Load 59366 84548 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. kC SIZING Page it HVAC -Zect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1186 sf Volume ........................... 13956 cf Heating Description (Btuh) Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Zone Load ZONE 'SLEEPING' 5255 11611 n/a 7369 n/a 2424 26659 n/a 26659 Floor Area ....................... 1469 sf Volume ........................... 14690 cf Heating Description (Btuh) Cooling (Btuh) 2873 11306 9895 5558 981 3061 33675 10102 43777 Cooling (Btuh) Opaque Conduction and Solar...... 7355 4165 Glazing Conduction ............... 4603 4482 Glazing Solar .................... n/a 3397 Infiltration ..................... 7757 5851 Internal Gain .................... n/a 1226 Ducts ............................ 1972 1912 Sensible Load .................... 21687 21034 Latent Load ...................... n/a 6310 Minimum Zone Load 21687 27344 kC SIZING Page 12 HVAC erect Title.......... Heritage, Plan 1B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERITIG3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 2011 1958 Glazing Solar .................... n/a 2529 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 390 Ducts ............................ 1002 939 Sensible Load .................... 11020 10329 Latent Load ...................... n/a 3099 Minimum Zone Load 11020 13427 Plan 2 Page 1 CF-1R TIFICATE OF COMPLIANCE: RESIDENTIAL Date........ 03/17/99 sect Title.......... Heritage, Plan 2B The Heritage Collection ******* sect Address........ La Quinta, CA CEA *v4.50*CEM ******* FB=uildingPermit # umentation Author... Beth Brummitt, , Haynal and Company, Inc. C ec Date 425 W 5th Ave Ste 201 p an Escondido, CA 92025 Fieid C ec Date 760-743-5408 _mate Zone........... 15 MICROPAS4 v4.50 for 1995 Standards by Enercomp,Inc. npliance Method...... MICROPAS4 v4.50 92 File-HERIT2 Wth-CTZ15SrRgnaTypicalCHouse Inc. User#-MP1657 User-Haynal and Company, GENERAL INFORMATION Conditioned Floor Area ..... 2872 sfFamily Detached Building Type .............. New Construction Building Type ......... Front Orientation. Cardinal - N,E,S,W Number of Dwelling Units... i Number of Stories.......... Floor Construction Type.... Slab On Grade Glazing Percentage......... 24.1 % of 0.61 Btu/hr-sf-F floor area Average Glazing U-value.... BUILDING SHELL INSULATION onent Frame Cavity Sheathing Insul Assembly R-value R-value U-value Location/Comments to Type R-value all Wood R-17 8 R-0 71R 8 R-22.48 0.061 To Garage 0.049 all Wood R-17.8 R-4.68 R-27 R-38 0.025 R-38 Attic oof Wood n /a R-11 R_0 R-n/a R-0 0.330 Solid Wood To Outside oor labEdge n/a R-0 R-n/a R-n/a R-0 R-0 0.900 0.720 e labEdge n/a n/a R-0 R-0 R-n/a R-0 To Garage labEdge FENESTRATION # of Interior Shading/ Over hang/ Framing Area U- Pan- Area Description Shading Fins Type )rientation (sf) Value es Jindow Front (N) 30.0 0.600 2 None None None Yes Yes Metal Metal 4indow Front (N) (N) 14.1 0.430 2 28.0 0.550 2 None None None Yes Yes Wood Metal Door window Front Front (N) 11.0 0.720 2 None None None None None window Left (E) (E) 3.5 0.570 2 25.0 0.600 2 None None None Yes None Metal Metal Window Window Left Left (E) 51.0 0.670 2 None None None Yes Metal Window Left (E) (S) 37.5 0.670 2 136.0 0.670 2 None None None Yes Yes Metal Metal Window Door Back Back (S) 80.0 0.580 2 None None None Yes Metal D'- Back (S) 112.0 0.530 2 None None Yes Metal �Ow Back (S) (W) 45.0 0.600 2 30.0 0.670 2 None None None None Yes Metal Metal W111dow Window Right Right (W) 53.0 0.600 2 None None None Yes None Window Right (W) 36.0 0.570 2 None Page 2 CF-1R03/17/99 'IFICATE OF COMPLIANCE: RESIDENTIAL 'ect Title.......... Heritage, Plan 2B Date........ MICROPAS4 v4.50 File-HERIT2 Program -FORM CHouse User#-MP1657 User-Hayna l and Compan15SI2 THERMAL MASS Area Thickness (in) Location/Comments Exposed (sf) Type — 3.5 Entry, Kitch,Hearth,WetBa S1abOnGrade Yes 199 ill 3.5 Baths,Laundry S1abOnGrade Yes 1218 3.5 Covered S1abOnGrade No 1364 3.5 Covered SlabOnGrade No HVAC SYSTEMS Minimum Duct Duct Thermostat R-value Type Equipment Type Efficiency Location 0.800 AFUE Attic R-4.2 LivingStat R-4.2 Livin�[Stat Furnace ACSplit 12.00 SEER Attic Attic R-4.2 SleepingStat Furnace 0.800 AFUE 12.00 SEER Attic R-4.2 SleepingStat ACSplit WATER HEATING SYSTEMS Number Tank External Size Insulation e Distribution Type in Energy System Factor (gal) R-value ink Type Heater Type 1 .52 EF 75 R-12 Gas Recirc/TimeTemp Storage SPECIAL FEATURES/REMARKS building with no orientation restrictions. his is a multiple orientation his printout is for the front facing rr,,,,,v nr rnMPLIANCE : RESIDENTIAL 4 tI c Heritage, Plan 2B Page 3 CF-1R n'1 /1'7 /QQ Date ........ v.I, 92 MICROPAS4 v4.50 File-HERIT2 Wth-CTZ15SInc.PrRgnaTypical House _U_M-01 Fri? User-Haynal and Company, COMPLIANCE STATEMENT features and performance ormance his certificate of compliance listWl thebuilding Parts 1 and 6 of the regulations to pecifications needed to comply the individual with alifornia Code of Regrtafi�ate has been sns, and the dignedsbyathe individual mplement them. This certificate When this certificate of compliance is iverall design responsibility. submitted for a single building plan to be built in multiplec°aleFeatuores/ Lny shading feature that is varied is indicated in the Sp temarks section. ION AUTHOR DESIGNER or OWNER Vame.... John Moore, Sr. Vice Pres "ompany. Brookfield Homes Address. 12865 p.oA ine Del Mar, 200 Del Mar, Phone... 619-481-8500 License. Signed ORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. date 7 D0CUMENTAT Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. Address. 425 W 5th Ave Ste 201 Escondido, CA 92025 Phone... 760-743-5408 LSigned.. 3 a7 Page 1 ..r, mvrnn CTTMMARY C-2R n-� /1-7 /99 j1-r'x 1•1 L L..,.. - -- Date . Heritage, Plan ll ******* ect Title.• •• The Heritage Collection *v4.50* ect Address..• La Quinta, CA ******* Building Permit CEM, CEA mentation Author• HaynaBeth Brand1Company, Inc. p an C ec Date 425 W 5th Ave Ste 201 Date Escondido, CA 92025 Fie C ec 760-743-5408 p Inc. pate Zone ... -,A _ : • 15 Enercom , .,.. . MICROPAS4 v4.50 for 1995 Standards y MICROPAS4 v4.50 File-HERIT2 Wth-CTZ15SInc PrRgnaTYpical House __a r,R,,, Grp TTser-Haynal and Company, U7ci.rr MICROPAS4ENERGY USE SUMMARY Energy Use (kBtu/sf -yr) Space Heating ..... •:: Space Cooling..••• Water Heating..••• North Total Space Heating ....... :: Space Cooling ...... • Water Heating ....... East Total Space Heating.......... Space Cooling..••• Water Heating.•••• South Total Space Heating ...... Space Cooling...•• Water Heating ..... West Total Standard Design 2.39 28.98 9.10 40.47 2.39 28.98 9.10 40.47 2.39 28.98 9.10 40.47 2.39 28.98 9.10 40.47 Proposed Design 2.12 23.53 8.78 34.43 2.74 24.06 8.78 35.58 2.87 23.74 8.78 35.39 2.21 23.66 8.78 34.65 Compliance Margin 0.27 5.45 0.32 6.04 -0.35 4.92 0.32 4.89 -0.48 5.24 0.32 5.08 0.18 5.32 0.32 5.82 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type .....•••• Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type ..... ••••• Floor Construction Type.... Number of Building Zones... 2872 sf Detached Single Family New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 2 Page 2 C-2R PUTER METHOD SUMMARY lect Title.......... Heritage, Plan 2B Date........ 03/17/99 i MICROPAS4 v4.50 File-HERIT2 Wth-CTZ15SI2 Progna -FORMIC-21k i7ser#-MP1657 User-Haynal and Company, Conditioned Volume......... 31371 2892 cf sf Footprint Area ............. 2892 sf Ground Floor Area .......... sf Slab -On -Grade Area......... 24.1 % of floor area Glazing Percentage......... Glazing U-value.... 0.61 Btu/hr-sf-F Average Average Ceiling Height..... 10.9 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area ne Type (sf) (cf) Units itioned Type (ft) (sf) VING esidence 1397 16621 0.49 Yes LivingStat 4.1 n/a IEEPING .esidence 1475 14750 0.51 Yes SleepingStat 3.2 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ irface (sf) value R-val Azm Tilt Gains Reference Comments NG 235 0.049 22.48 0 90 Yes W.19.2X6.16F all 7 Wall 536 0.049 22.48 90 90 Yes W.19.2X6.1 3 Wall 222 0.049 22.48 180 90 Yes W.19.2X6.16F 3 Wall 125 0.049 22.48 270 90 Yes W.19.2X6.16F 1 Roof 1417 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic LEEPING 1 Wall 314 0.061 17.8 0 90 No W.19.2X6.16G To Garage 2 Wall 167 0.049 22.48 90 90 Yes W.19.2X6.16F 3 Wall 30 0.061 17.8 90 90 No W.19.2X6.16G 4 Wall 52 0.049 22.48 180 90 Yes W.19.2X6.16F 5 Wall 456 0.049 22.48 270 90 Yes W.19.2X6.16F 0 Roof 1475 0.025 38 n/a 0 Yes R.38.2X4.24 -38 Attic 2 Door 21 0.330 0 0 90 No None Solid Wood PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVING No To Outside 13 SlabEdge 5 0.900 R-0 14 SlabEdge 126 0.720 R-0 No To Outside SLEEPING No To Outside 15 SlabEdge 5 0.900 R-0 No To Outside 16 SlabEdge 84 0.720 R-0 17 SlabEdge 36 0.500 R-0 No To Garage Page 3 ..-rnrxnT) crrnrMARY J-ini-, ,,J.'. .._ - liaLc... ..... Heritage, Plan 2B ry 7 D File-HERIT2 Wth-CTZ15SInc Program-ru�,•, Run -Typical House MICROPAS4 v4.50 na1 and Company, ___a �Rn, cry User -Hay USCltr .... _ C-2R nZ/1'7/99 FENESTRATION SURFACES SC SC Interior ## of Vent Act Glass Int Shading/ Area Pan- Frame Open U- Shade Description value Azm Tlt Only Face (sf) es Type �'- - - 0.600 0 90 0.47 0.78 None ING 2 Metal Std 0 g0 0.47 0.78 None Window 1 .0 Metal Std 0.430 55 Window 14.1 2 Std 0.550 0 90 0.88 0.78 None Door 28.0 2 Wood Std 0.720 0 90 0.88 0.78 None Window 11.0 2 Metal Std 0.670 90 90 0.66 0.78 None Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None Window 22.5 2 Metal Std 0.670 90 90 0.66 0.78 None Window 37.5 2 Metal Std 0.670 180 90 0.66 0.78 None Window 38.0 2 Metal Std 0.670 180 90 0.66 0.78 None Window 38.0 2 Metal Std 0.580 180 90 0.66 0.78 None Door 80.0 2 Metal Std 0.670 180 90 0.66 0.78 None Window 30.0 2 Metal Std 0.530 180 90 0.47 0.78 None Door 64.0 2 Metal Std 0.670 180 90 0.66 0.78 None Window 30.0 2 Metal Std 0.670 270 90 0.66 0.78 None Window 30.0 2 Metal ,EEPING None Std 0.570 90 90 0.88 0.78 None indow 3.5 2 Metal Std 0.600 90 90 0.47 0.78 None indow 48.0 2 Metal Std 0.530 180 90 0.47 0.78 None boor 48.0 2 Metal Std 0.600 180 90 0.47 0.78 None 7 Window 45.0 2 Metal Std 0.600 270 90 0.47 0.78 None D Window 12.0 2 Metal Std 0.600 270 90 0.47 0.78 None 0 Window 16.0 2 None Std 0.570 270 90 0.88 0.78 None 1 Window 36.0 2 Std 0.600 270 90 0.47 0.78 None 2 Window 25.0 2 Metal OVERHANGS AND SIDE FINS Window- -Overhang- Left Fin Right Fin- -Window- Rght th Hght Ext Dpth Hght Area th Hght Ext Ext Ext Dp Surface (sf) Hght Wdth Dp - n/a n/a n/a n/a n/a n/a LIVING 6 2.5 4 n/a n/a 1 Window 30.0 5 6 2.5 5 n/a n/a n/a n/a 1/5 1.5 2/a 1.5 2 Window 14.1 3 3.5 2 5 1.5 1.5 1.5 2 1.5 1.5 2 1.5 3 Door 28.0 8 5 1.5 1.5 1.5 n/a n/a n/a 11.0 3.5 5 2 0 5 n/a n/a n/a n/a n/a 4 Window 37.5 7.5 5 21 255 n/a n/a n/a n/a n/a n/a n/a g Window 4 9.5 .5 13 .5 n/a n/a 10 Window 38.0 9.5 4 9 5 5 5 n/ n/a n/a n/a n/a 11 Window 38.0 9.5 9.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a 80.0 10 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a 12 Door 8 n/a n/a 13 Window 30.0 7.5 8 8 1.5 n/a n/a n/a n/a n/a n/a 14 Door 64.0 8 8 5 n/a n/a n/a n/a 15 Window 30.0 7.5 3 n/a n/a n/a n/a n/a n/a SLEEPING 5 1.5 2 n/a n/a n/a n/a n/a n/a rgindow 25.0 5 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a i door 48.0 8 6 2.5 .5 n/a n/a n/a n/a n/a n/a Uindow 45.0 7.5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a 12.0 2 6 n/a n/a n/a n/a 20 Window 5 1.5 1.5 n/a 19 Window 16.0 2 8 1.5 1.5 n/a n/a n/a n/a n/a n/a 21 Window 36.0 6 Page 4 C-2R 'UTER METHOD SUMMARY , 03/17/99 -«- rr 4 t l a . Heritage, Plan 2B Date....... Program -FORM U-/-K MICROPAS4 v4.50 erle-HERIT2 Company5Slnc•Run-Typical House TT.--4_MDl F57 US y nal OVERHANGS AND SIDE FINS Window— Overhang Left Fin Right Fin — Area Left Rght Hght Ext Dpth Hght face (sf) Hght Wd_ Dpth Hght Ext Ext Ext Dpth 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 25.0 5 THERMAL MASS Area Thick Heat Conduct- R rface (sf) (in) Cap ivity value Location/Comments ;s Type _ VING 0 0.98 R-0.0 Entry,Kitch,Hearth,WetBar 28 S1abOnGrade 199 3.5 R-2,0 Covered S1abOnGrade 1218 3.5 28.0 0.98 EEPING 28.0 0.98 R-0.0 Baths,Laundry S1abOnGrade 111 3.5 28 0 0.98 R-2.0 Covered S1abOnGrade 1364 3.5 HVAC SYSTEMS Duct Duct Duct Minimum R-value Efficiency System Type Efficiency Location LIVING R-4,2 0.830 Furnace 0.800 AFUE Attic R-4 2 0.810 ACSplit 12.00 SEER Attic SLEEPING R-4.2 0.830 Furnace 0.800 AFUE Attic R-4 2 0.810 ACSplit 12.00 SEER Attic WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type e System Factor (gal) R-value 1 Storage Gas Recirc/TimeTemp 1 .52 75 R-12 SPECIAL FEATURES REMARKS no orientation restrictions. This is a multiple orientation building with This printout is for the front facing Calculation for Ventilation Height Heritage: Plan 2 Gross Weighted Opening Gross Effective Vent Vent Area Horizontal Center Vent Area * Average Height Area % Area Inlet Outlet Inlet Outlet Height Height Height SLEEPING ZONE: Sliding windows/doors 0.1 0 0 0 5050 5 25 0.1 2.5 1.25 1.25 1.25 3.75 2.5 62.5 6080 8 48 0.1 4.8 2.4 2.4 2 6 4 192 3076 7.5 22.5 0.1 2.25 1.125 1.125 1.875 5.625 3.75 84.375 3076 7.5 22.5 0.1 2.25 1.125 1.125 1.875 5.625 3.75 84.375 4020 2 8 0.1 0.8 0.4 0.4 0.5 1.5 1 8 4020 2 8 0.1 0.8 0.4 0.4 0.5 1.5 1 8 5050 5 25 0.1 2.5 1.25 1.25 1.25 3.75 2.5 62.5 Hinged windows/doors 0 0.2 0 0 0 0 0 0 0 none Total Operable 159 15.9 7.95 7.95 501.75 3.2 Fixed windows 0 0 GB-2-1313 3.5 3-2020 12 GB-6060 36 Total Sleeping 210.5 LIVING ZONE: Sliding windows/doors 0.1 0 0 0 6050 10 30 0.1 3 1.5 1.5 2.5 7.5 5 150 80100 10 80 0.1 8 4 4 2.5 7.5 5 400 8080 5 64 0.1 6.4 3.2 3.2 1.25 3.75 2.5 160 Hinged windows/doors 0 0.2 0 0 0 0 0 0 0 3680 8 28 0.2 5.6 2.8 2.8 2 6 4 112 Total Operable 202 23 11.5 11.5 8221 4.1 Fixed windows 0.0 0 transoms n/a 25.0 3096 n/a 28.5 24096 n/a 76.0 8076 n/a 76.0 3-4076 n/a 90.0 Total Living 497.5 TOTAL Fenestration 708.0 heritage cr / Vent Height Plan 2 3/19/99 Plan 2 with Guest 2 R'FIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R ect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 )ect Address........ The Heritage Collection ******- La Quinta, CA *v4.50* cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date imate Zone........... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House vonent ape GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Stories. ....... Floor Construction Type.... Glazing Percentage......... Average Glazing U-value.... 3308 sf Single Family Detached New Cardinal - N,E,S,W 1 1 Slab On Grade 22.9 % of floor area 0.6 Btu/hr-sf-F BUILDING SHELL INSULATION Frame Cavity Sheathing Insul Assembly Type R-value R-value R-value U-value Location/Comments �11 Wood R-17.8 R-0 R-17.8 0.061 To Garage �11 Wood R-17.8 R-4.68 R-22.48 0.049 )of Wood R-11 R-27 R-38 0.025 R-38 Attic )or n/a R-0 R-n/a R-0 0.330 Solid Wood _abEdge n/a R-0 R-n/a R-0 0.900 To Outside _abEdge n/a R-0 R-n/a R-0 0.720 To Outside LabEdge n/a R-0 R-n/a R-0 0.500 To Garage FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing rientation (sf) Value es Description Shading Fins Type indow Front (N) 30.0 0.600 2 None None Yes Metal indow Front (N) 14.1 0.430 2 None None Yes Metal Dor Front (N) 28.0 0.550 2 None None Yes Wood indow Front (N) 11.0 0.720 2 None None Yes Metal indow Left (E) 3.5 0.570 2 None None None None indow Left (E) 25.0 0.600 2 None None Yes Metal indow Left (E) 51.0 0.670 2 None None None Metal indow Left (E) 37.5 0.670 2 None None Yes Metal indow Back (S) 136.0 0.670 2 None None Yes Metal oor Back (S) 80.0 0.580 2 None None Yes Metal oor Back (S) 112.0 0.530 2 None None Yes Metal ow Back (S) 45.0 0.600 2 None None Yes Metal ow Right (W) 30.0 0.670 2 None None None Metal indow Right (W) 53.0 0.600 2 None None Yes Metal indow Right (W) 36.0 0.570 2 None None Yes None RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R ect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM CF-lR User#-MP1657 User-Haynal and Company, Inc. Run -Typical House FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing •ientation (sf) Value es Description Shading Fins Type .ndow Right (W) 6.0 0.570 2 None None None None .ndow Right (W) 8.0 0.430 2 None None None Metal )or Back (S) 45.0 0.530 2 None None None Metal .ndow Left (E) 6.0 0.600 2 None None None Metal Type S1abOnGrade S1abOnGrade S1abOnGrade S1abOnGrade S1abOnGrade Exposed Yes Yes No No No THERMAL MASS Area Thickness (sf) (in) Location/Comments 199 3.5 Entry,Kitch,Hearth,WetBa ill 3.5 Baths,Laundry 1218 3.5 Covered 1364 3.5 Covered 436 3.5 Covered HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace ACSplit Furnace ACSplit Furnace ACSplit 0.800 AFUE Attic 12.00 SEER Attic 0.800 AFUE Attic 12.00 SEER Attic 0.800 AFUE Attic 12.00 SEER Attic R-4.2 R-4.2 R-4.2 R-4.2 R-4.2 R-4.2 LivingStat LivingStat SleepingStat SleepingStat SleepingStat SleepingStat WATER HEATING SYSTEMS Tank Type Heater Type Distribution Type Number Tank External in Energy Size Insulation System Factor (gal) R-value Storage Gas Recirc/TimeTemp 1 .52 EF 75 R-12 SPECIAL FEATURES/REMARKS his is a multiple orientation building with his printout is for the front facing North. no orientation restrictions. RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R erect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. Name.... Company. Address. Phone... License. Signed. Name.. Title.. Agency. Phone... DESIGNER or OWNER John Moore, Sr. Vice Pres Brookfield Homes 12865 Pointe Del Mar, 200 Del Mar, CA 92014 619-481-8500 Signed. date DOCUMENTATION AUTHOR Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. Address. 425 W 5th Ave Ste 201 Escondido, CA 92025 Phone... 760-743-5408 Signed.. S� Matt?) 4PUTER METHOD SUMMARY Page 1 C-2R -iect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 ect Address........ The Heritage Collection ******* La Quinta, CA *v4.50* ::umentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date imate Zone........... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM C-2R I User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.78 2.36 0.42 Space Cooling.......... 29.89 23.17 6.72 Water Heating.......... 7.90 7.62 0.28 North Total 40.57 33.15 7.42 Space Heating.......... 2.78 3.04 -0.26 Space Cooling.......... 29.89 23.63 6.26 Water Heating.......... 7.90 7.62 0.28 East Total 40.57 34.29 6.28 Space Heating.......... 2.78 3.20 -0.42 Space Cooling.......... 29.89 23.19 6.70 Water Heating.......... 7.90 7.62 0.28 South Total 40.57 34.01 6.56 Space Heating.......... 2.78 2.47 0.31 Space Cooling.......... 29.89 23.30 6.59 Water Heating.......... 7.90 7.62 0.28 West Total 40.57 33.39 7.18 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3308 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 MPUTER METHOD SUMMARY Page 2 C-2R erect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U-value.... Average Ceiling Height..... Floor Area )ne Type (sf) XING residence 1397 .jEEPING residence 1475 JEST tesidence 436 Area ace (sf) LVING 5 Wall 235 7 Wall 536 3 Wall 222 � Wall 125 5 Roof 1417 LEEPING 1 Wall 314 2 Wall 167 3 Wall 30 4 Wall 52 5 Wall 456 4 Roof 1475 7 Door 21 UEST 0 Wall 153 1 Wall 228 2 Wall 108 3 Wall 220 6 Roof 436 35295 cf 3328 sf 3328 sf 3328 sf 22.9 % of floor area 0.6 Btu/hr-sf-F 10.7 ft BUILDING ZONE INFORMATION # of Volume Dwell Cond- (cf) Units itioned 16621 0.42 Yes 14750 0.45 Yes 3924 0.13 Yes OPAQUE SURFACES U- Insul Act Solar value R-val Azm Tilt Gains 0.049 22.48 0 0.049 22.48 90 0.049 22.48 180 0.049 22.48 270 0.025 38 n/a 0.061 17.8 0 0.049 22.48 90 0.061 17.8 90 0.049 22.48 180 0.049 22.48 270 0.025 38 n/a 0.330 0 0 0.049 22.48 0 0.049 22.48 90 0.049 22.48 180 0.049 22.48 270 0.025 38 n/a Thermostat Type Vent Special Height Vent Area (ft) (sf) LivingStat 4.1 n/a SleepingStat 3.2 n/a SleepingStat 2.0 n/a Form 3 Location/ Reference Comments 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 0 Yes R.38.2X4.24 R-38 Attic 90 No W.19.2X6.16G To Garage 90 Yes W.19.2X6.16F 90 No W.19.2X6.16G 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 0 Yes R.38.2X4.24 R-38 Attic 90 No None Solid Wood 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 90 Yes W.19.2X6.16F 0 Yes R.38.2X4.24 R-38 Attic MPUTER METHOD SUMMARY Page 3 C-2R erect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Surface LIVING PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 18 SlabEdge 5 0.900 R-0 No To Outside 19 SlabEdge 126 0.720 R-0 No To Outside SLEEPING 20 SlabEdge 5 0.900 R-0 No To Outside 21 SlabEdge 84 0.720 R-0 No To Outside 22 SlabEdge 36 0.500 R-0 No To Garage GUEST 23 SlabEdge 10 0.900 R-0 No To Outside 24 SlabEdge 76 0.720 R-0 No To Outside FENESTRATION SURFACES irf ace :VING Rendow ndow 4 Door 6 Window i Window 3 Window Window Window L Window ? Door 3 Window I Door i Window 3 Window SEEPING Window 5 Window 5 Door 7 Window a Window 3 Window L Window 2 Window JEST 3 Window 4 Window 5 Door 6 Window # of Vent Sc SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ (sf) es Type Type value Azm Tlt Only Shade Description 30.0 2 Metal Std 0.600 0 90 0.47 0.78 None 14.1 2 Metal Std 0.430 0 90 0.47 0.78 None 28.0 2 Wood Std 0.550 0 90 0.88 0.78 None 11.0 2 Metal Std 0.720 0 90 0.88 0.78 None 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None 22.5 2 Metal Std 0.670 90 90 0.66 0.78 None 37.5 2 Metal Std 0.670 90 90 0.66 0.78 None 38.0 2 Metal Std 0.670 180 90 0.66 0.78 None 38.0 2 Metal Std 0.670 180 90 0.66 0.78 None 80.0 2 Metal Std 0.580 180 90 0.66 0.78 None 30.0 2 Metal Std 0.670 180 90 0.66 0.78 None 64.0 2 Metal Std 0.530 180 90 0.47 0.78 None 30.0 2 Metal Std 0.670 180 90 0.66 0.78 None 30.0 2 Metal Std 0.670 270 90 0.66 0.78 None 3.5 2 None Std 0.570 90 90 0.88 0.78 None 25.0 2 Metal Std 0.600 90 90 0.47 0.78 None 48.0 2 Metal Std 0.530 180 90 0.47 0.78 None 45.0 2 Metal Std 0.600 180 90 0.47 0.78 None 12.0 2 Metal Std 0.600 270 90 0.47 0.78 None 16.0 2 Metal Std 0.600 270 90 0.47 0.78 None 36.0 2 None Std 0.570 270 90 0.88 0.78 None 25.0 2 Metal Std 0.600 270 90 0.47 0.78 None 6.0 2 None Std 0.570 270 90 0.88 0.78 None 8.0 2 Metal Std 0.430 270 90 0.47 0.78 None 45.0 2 Metal Std 0.530 180 90 0.47 0.78 None 6.0 2 Metal Std 0.600 90 90 0.47 0.78 None MPUTER METHOD SUMMARY Page 4 C-2R -zect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght .rface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght VING Window 30.0 5 6 2.5 4 n/a n/a n/a n/a n/a n/a n/a n/a Window 14.1 3 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Door 28.0 8 3.5 2 5 1.5 1.5 1.5 2 1.5 1.5 2 1.5 Window Window 11.0 37.5 3.5 7.5 3.5 5 2 21 .5 2.5 1.5 0 1.5 5 1.5 n/a 2 n/a 1.5 n/a 1.5 n/a 2 n/a 1.5 n/a i Window 38.0 9.5 4 9.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 38.0 9.5 4 9.5 .5 .5 16 .5 13 .5 n/a n/a n/a Door 80.0 10 8 9.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 30.0 7.5 4 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a Door 64.0 8 8 8 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 30.0 7.5 3 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a 'EEPING Window 25.0 5 5 1.5 2 n/a n/a n/a n/a n/a n/a n/a n/a Door 48.0 8 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 45.0 7.5 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 12.0 2 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a indow 16.0 2 8 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a indow 36.0 6 5 1.5 1.5 n/a n/a n/a n/a n/a n/a Window 25.0 5 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a iss Type CVING L SlabOnGrade 3 SlabOnGrade =PING Z SlabOnGrade 4 SlabOnGrade JEST 5 SlabOnGrade THERMAL MASS Area Thick Heat Conduct- Surface (sf) (in) Cap ivity R-value Location/Comments 199 3.5 28.0 1218 3.5 28.0 ill 3.5 28.0 1364 3.5 28.0 436 3.5 28.0 0.98 R-0.0 0.98 R-2.0 0.98 R-0.0 0.98 R-2.0 0.98 R-2.0 HVAC SYSTEMS Entry,Kitch,Hearth,WetBar Covered Baths,Laundry Covered Covered Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 SLEEPING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 GUEST Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 )MPUTER METHOD SUMMARY Page 5 C-2R ect Title.......... Heritage, Plan 2B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT2G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House 'ank Type 1 Storage WATER HEATING SYSTEMS Number Tank in Energy Size Heater Type Distribution Type System Factor (gal) Gas Recirc/TimeTemp 1 .52 75 SPECIAL FEATURES/REMARKS External Insulation R-value R-12 its is a multiple orientation building with no orientation restrictions. its printout is for the front facing North. Plan 2 with Guest 3 .,n nnMDT,T"CE: RESIDENTIAL Page 1 CF-1R n'� /19 /99 Heritage, Plan 2B, Guest3 ******* sct Title.......... act Address ........ The *v4.50* La QHer ntaagCACollection *4.50* Building permit mentation Author. CEM, CEA HaynaBeth B and1Company, Inc. p an C ec Date 425 W 5th Ave Escondido, CA 5920251 Fie C ec Date 760-743-5408 late Zone ........... 15 OPAS4 v4.50 for 1995 Standards by Enercomp, Inc. mICR )liance Method...... WZ15S92 Program -FORM CF-1 MICROPAS4 v4.50 ile-HERIT2G3 Fnal and User -Hay Company, Inc. Run -Typical House User#-Mp1657 GENERAL INFORMATION Conditioned Floor Area..... Building Type • . • . Construction Type •••• Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type .... Glazing Percentage......... Average Glazing U-value.... BUILDING SHELL INSULATION 3476 sf Detached Single Family New Cardinal - N,E,S,W 1 1 Slab On Grade 22.7 % of floor area 0.6 Btu/hr-sf-F Frame Fra Cavity Sheathing Insul Assembly R-value U-value Location/Comments ,gonent ape Type lue R-va� R-value ------- � 0.061 To Garage ill Wood R-17.8 R-17.8 R-0 R-4.68 R-17.8 R-22.48 0.049 0.025 R-38 Attic �11 Wood Wood R-11 R-27 R-38 R-0 0.330 Solid Wood Outside :)OfR-n/a for n�a R-0 R-0 R-n/a R-0 R-0 0.900 0.720 To To Outside labEdge labEdge n/a R-0 R-n/a R-n/a R-0 0.500 To Garage labEdge n/a R-0 FENESTRATION )rientation dindow Window Door Window Window Window Window Window Window Door Door p' ow h ow Window Window Front Front Front Front Left Lef t Lef t Left Back Back Back Back Right Right Right # of Area U- Pan- (sf) Value es (N) 30.0 0.600 2 2 (N) 14.1 0.430 2 (N) 28.0 0.550 2 (N) 11.0 0.720 2 (E) 3.5 0.570 2 (E) 25.0 0.600 2 (E) 51.0 0.670 2 (E) 37.5 0.670 (S) 136.0 0.670 2 2 (S) 80.0 0.580 2 (S) 112.0 0.530 2 (S) 45.0 0.600 2 (W) 30.0 0.670 2 (W) 53.0 0.600 2 (W) 36.0 0.570 Interior Shading/ Description None None None None None None None None None None None None None None None Exterior Shading None None None None None None None None None None None None None None None Over- hang/ Framing Fins Type Yes Metal Yes Metal Yes Wood Yes Metal None None Yes Metal None Metal Yes Metal Yes Metal Yes Metal Yes Metal Yes Metal None Metal Yes Metal Yes None rIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R sect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 i MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM House User#-MP1657 User-Haynal and Company, Inc. Run -Typical FENESTRATION ## of Interior Shading/ Over - Exterior hang/ Framing Area U- (sf) Value Pan- es Description Shading Fins Type .entation idow Front (N) 30.0 0.600 2 None None None None None Metal Metal idow Front (N) 4.5 0.430 2 None 2 None None None Metal idow Left (E) Back (S) 8.0 0.430 45.0 0.530 2 None None None None Metal Metal Dr Zdow Right (W) 8.0 0.430 2 None None THERMAL MASS Area Thickness n (sf) (in) Location/Comments Type Exposed 199 3.5 Entry,Kitch,Hearth,WetBa S1abOnGrade Yes ill 3.5 Baths,Laundry SlabOnGrade Yes 1218 3.5 Covered S1abOnGrade No 1364 3.5 Covered S1abOnGrade No 604 3.5 Covered S1abOnGrade No HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic Attic R-4.2 Setback R-4.2 Setback ACSplit 12.00 0.800 SEER AFUE Attic R-4.2 Setback Furnace ACSplit 12.00 SEER Attic R-4.2 Setback R-4.2 Setback Furnace 0.800 12.00 AFUE Attic SEER Attic R-4.2 Setback ACSplit WATER HEATING SYSTEMS Number Tank Size External Insulation in Energy Distribution Type System Factor (gal) R-value Tank Type Heater Type DHWl 1 .52 EF 75 R-12 Storage Gas Recirc/TimeTemp DHW2 1 .535 EF 40 R-12 Storage Gas Standard SPECIAL FEATURES/REMARKS Chis is a multiple orientation building with no orientation restrictions. Phis printout is for the front facing North. ZTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF 1R 4� ect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. Name.... Company. Address. Phone... License. Signed Name.. Title. Agency Phone... DESIGNER or OWNER John Moore, Sr. Vice Brookfield Homes 12865 Pointe Del Mar, Del Mar, CA 92014 619-481-8500 Pres 200 Signed.. date DOCUMENTATION AUTHOR Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. Address. 425 W 5th Ave Ste 201 Escondido, CA 92025 Phone... 760-743-5408 Signed.. 3 `� (date) - MPUTER METHOD SUMMARY Page 1 C-2R ect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 l ect Address........ The Heritage Collection ******* La Quinta, CA *v4.50* cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit if Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan C ec Date Escondido, CA 92025 760-743-5408 Field C ec Date imate Zone........... 15 impliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM C-2R I User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.82 2.44 0.38 Space Cooling.......... 29.88 25.68 4.20 Water Heating.......... 7.52 9.25 -1.73 North Total 40.22 37.37 2.85 Space Heating.......... 2.82 3.05 -0.23 Space Cooling.......... 29.88 26.19 3.69 Water Heating.......... 7.52 9.25 -1.73 East Total 40.22 38.49 1.73 Space Heating.......... 2.82 3.13 -0.31 Space Cooling.......... 29.88 25.63 4.25 Water Heating.......... 7.52 9.25 -1.73 South Total 40.22 38.01 2.21 Space Heating.......... 2.82 2.57 0.25 Space Cooling.......... 29.88 26.29 3.59 Water Heating.......... 7.52 9.25 -1.73 West Total 40.22 38.11 2.11 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3476 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 MPUTER METHOD SUMMARY Page 2 C-2R -sect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House >ne Type Conditioned Volume......... 36807 cf Footprint Area ............. 3496 sf Ground Floor Area.......... 3496 sf Slab -On -Grade Area......... 3496 sf Glazing Percentage......... 22.7 % of floor area Average Glazing U-value.... 0.6 Btu/hr-sf-F Average Ceiling Height..... 10.6 ft BUILDING ZONE INFORMATION Floor Area (sf) # of Volume Dwell Cond- (cf) Units itioned Vent Special Thermostat Height Vent Area Type (ft) (sf) :VING zesidence 1397 16621 0.40 Yes Setback 4.1 n/a jEEPING zesidence 1475 14750 0.43 Yes Setback 3.2 n/a JEST zesidence 604 5436 0.17 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Vace (sf) value R-val Azm Tilt Gains Reference Comments CVING Wall 235 0.049 22.48 0 90 Yes W.19.2X6.16F 7 Wall 536 0.049 22.48 90 90 Yes W.19.2X6.16F 3 Wall 222 0.049 22.48 180 90 Yes W.19.2X6.16F Wall 125 0.049 22.48 270 90 Yes W.19.2X6.16F Roof 1417 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic =PING L Wall 314 0.061 17.8 0 90 No W.19.2X6.16G To Garage 2 Wall 167 0.049 22.48 90 90 Yes W.19.2X6.16F 3 Wall 30 0.061 17.8 90 90 No W.19.2X6.16G 4 Wall 52 0.049 22.48 180 90 Yes W.19.2X6.16F 5 Wall 456 0.049 22.48 270 90 Yes W.19.2X6.16F 4 Roof 1475 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 7 Door 21 0.330 0 0 90 No None Solid Wood UEST 0 Wall 155 0.049 22.48 0 90 Yes W.19.2X6.16F 1 Wall 289 0.049 22.48 90 90 Yes W.19.2X6.16F 2 Wall 144 0.049 22.48 180 90 Yes W.19.2X6.16F 3 Wall 289 0.049 22.48 270 90 Yes W.19.2X6.16F 6 Roof 604 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic )MPUTER METHOD SUMMARY Page 3 C-2R ect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments LIVING 18 SlabEdge 5 0.900 R-0 No To Outside 19 SlabEdge 126 0.720 R-0 No To Outside SLEEPING 20 SlabEdge 5 0.900 R-0 No To Outside 21 SlabEdge 84 0.720 R-0 No To Outside 22 SlabEdge 36 0.500 R-0 No To Garage GUEST 23 SlabEdge 108 0.720 R-0 No To Outside FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ zrface (sf) es Type Type value Azm Tlt Only Shade Description CVING L Window 30.0 2 Metal Std 0.600 0 90 0.47 0.78 None indow 14.1 2 Metal Std 0.430 0 90 0.47 0.78 None oor 28.0 2 Wood Std 0.550 0 90 0.88 0.78 None I Window 11.0 2 Metal Std 0.720 0 90 0.88 0.78 None 1 Window 28.5 2 Metal Std 0.670 90 90 0.66 0.78 None 3 Window 22.5 2 Metal Std 0.670 90 90 0.66 0.78 None ) Window 37.5 2 Metal Std 0.670 90 90 0.66 0.78 None ) Window 38.0 2 Metal Std 0.670 180 90 0.66 0.78 None L Window 38.0 2 Metal Std 0.670 180 90 0.66 0.78 None 2 Door 80.0 2 Metal Std 0.580 180 90 0.66 0.78 None 3 Window 30.0 2 Metal Std 0.670 180 90 0.66 0.78 None I Door 64.0 2 Metal Std 0.530 180 90 0.47 0.78 None 5 Window 30.0 2 Metal Std 0.670 180 90 0.66 0.78 None 3 Window 30.0 2 Metal Std 0.670 270 90 0.66 0.78 None =PING Window 3.5 2 None Std 0.570 90 90 0.88 0.78 None 5 Window 25.0 2 Metal Std 0.600 90 90 0.47 0.78 None 5 Door 48.0 2 Metal Std 0.530 180 90 0.47 0.78 None 7 Window 45.0 2 Metal Std 0.600 180 90 0.47 0.78 None a Window 12.0 2 Metal Std 0.600 270 90 0.47 0.78 None D Window 16.0 2 Metal Std 0.600 270 90 0.47 0.78 None 1 Window 36.0 2 None Std 0.570 270 90 0.88 0.78 None 2 Window 25.0 2 Metal Std 0.600 270 90 0.47 0.78 None JEST 3 Window 30.0 2 Metal Std 0.600 0 90 0.47 0.78 None 4 Window 4.5 2 Metal Std 0.430 0 90 0.47 0.78 None 5 Window 8.0 2 Metal Std 0.430 90 90 0.47 0.78 None 6 Door 45.0 2 Metal Std 0.530 180 90 0.47 0.78 None 7 Window 8.0 2 Metal Std 0.430 270 90 0.47 0.78 None a )MPUTER METHOD SUMMARY Page 4 C-2R --''ect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght irface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght [VING L Window 30.0 5 6 2.5 4 n/a n/a n/a n/a n/a n/a n/a n/a ? Window 14.1 3 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a 1 Door 28.0 8 3.5 2 5 1.5 1.5 1.5 2 1.5 1.5 2 1.5 E Window 11.0 3.5 3.5 2 .5 1.5 1.5 1.5 2 1.5 1.5 2 1.5 ) Window 37.5 7.5 5 21 2.5 0 5 n/a n/a n/a n/a n/a n/a ) Window 38.0 9.5 4 9.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a L Window 38.0 9.5 4 9.5 .5 .5 16 .5 13 .5 n/a n/a n/a ? Door 80.0 10 8 9.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 30.0 7.5 4 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a I Door 64.0 8 8 8 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 30.0 7.5 3 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a SEEPING 5 Window 25.0 5 5 1.5 2 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 48.0 8 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 45.0 7.5 6 2.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a a Window 12.0 2 6 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 'Vindow 16.0 2 8 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a hindow 36.0 6 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Z Window 25.0 5 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface ass Type (sf) (in) Cap ivity R-value Location/Comments IVING 1 SlabOnGrade 199 3.5 28.0 0.98 R-0.0 Entry,Kitch,Hearth,WetBar 3 SlabOnGrade 1218 3.5 28.0 0.98 R-2.0 Covered LEEPING 2 SlabOnGrade 111 3.5 28.0 0.98 R-0.0 Baths,Laundry 4 SlabOnGrade 1364 3.5 28.0 0.98 R-2.0 Covered UEST 5 SlabOnGrade 604 3.5 28.0 0.98 R-2.0 Covered HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 SLEEPING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 GUEST Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 )MPUTER METHOD SUMMARY Page 5 C-2R ect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/19/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation 'ank Type Heater Type Distribution Type System Factor (gal) R-value )HW1 1 Storage Gas Recirc/TimeTemp 1 .52 75 R-12 )HW2 2 Storage Gas Standard 1 .535 40 R-12 SPECIAL FEATURES/REMARKS its is a multiple orientation building with no orientation restrictions. its printout is for the front facing North. Plan 2 HVAC Loads 0 Page 1 HVAC C SIZING Heritage Plan 2B, Guest3 Date........ 03/18/99 T ct Title.......... Ict Address........ The Heritage Collection *v4.50* La Quinta, CA umentation Author... Beth Brummitt, CEM, CEA ******* Building Permit # Haynal and Company, Inc. Plan Check Date 425 W 5th Ave Ste 201 Escondido, CA 92025 Field C ec Date 760-743-5408 .mate Zone........... 15 ipliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. 3476 sf Volume ..................... 36807 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ PALM DESERT Latitude... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design ....... 34 F Summer Range ............... No Interior Shading Used...... Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Description Opaque Conduction and Solar...... 18993 201 00 17414 Glazing Conduction ............... 17885 n/a 13259 Glazing Solar .................... 19436 14659 Infiltration ..................... n/a 2607 Internal Gain .................... Ducts ............................ 5631 5814 Sensible Load .................... 61945 63953 n/a 19186 Latent Load ...................... Minimum Total Load 61945 83139 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. C SIZING Page 2 HVAC 4ect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1397 sf 16621 cf Volume ........................... Heating Description (Btuh) Opaque Conduction and Solar...... 7007 Glazing Conduction ............... 11333 n/a Glazing Solar .................... Infiltration ..................... 8777 n/a Internal Gain .................... 2712 Ducts ............................ Sensible Load .................... 29828 Latent Load ...................... n/a Minimum Zone Load 29828 ZONE 'SLEEPING' Floor Area ....................... 1475 sf 14750 cf Volume ........................... Heating Description (Btuh) Opaque Conduction and Solar ...... 6849 Glazing Conduction .............. n/a Glazing Solar .................... 7789 Infiltration ..................... n/a Internal Gain .................... 1926 Ducts ............................ Sensible Load .................... 21191 n/a Latent Load ...................... Minimum Zone Load 21191 Cooling (Btuh) 3888 11035 6645 6620 1090 2928 32205 9662 41867 Cooling (Btuh) 3963 4505 5335 5874 1158 2084 22919 6876 29794 AC SIZING Page 3 HVAC erect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 Glazing Conduction ............... 1925 Glazing Solar .................... n/a Infiltration ..................... 2870 Internal Gain .................... n/a Ducts ............................ 993 Sensible Load .................... 10926 Latent Load ...................... n/a Minimum Zone Load 10926 2348 1875 1279 2165 359 803 8828 2649 11477 AC SIZING Page 4 HVAC erect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume.. ... ............ Front Orientation.......... Sizing Location............ Latitude... .. ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. ... ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3476 sf 36807 cf Front Facing 90 deg PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 18993 10200 Glazing Conduction ............... 17885 17414 Glazing Solar .................... n/a 15079 Infiltration ..................... 19436 14659 Internal Gain .................... n/a 2607 Ducts ............................ 5631 5996 Sensible Load .................... 61945 65954 Latent Load ...................... n/a 19786 (E) Minimum Total Load 61945 85740 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. r'' AC SIZING Page 5 HVAC Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1397 sf Volume ........................... 16621 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7007 3888 Glazing Conduction ............... 11333 11035 Glazing Solar .................... n/a 9138 Infiltration ..................... 8777 6620 Internal Gain .................... n/a 1090 Ducts ............................ 2712 3177 Sensible Load .................... 29828 34948 Latent Load ...................... n/a 10484 Minimum Zone Load 29828 45432 ZONE 'SLEEPING' Floor Area ....................... 1475 sf Volume ........................... 14750 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6849 3963 Glazing Conduction ............... 4627 4505 Glazing Solar .................... n/a 3411 Infiltration ..................... 7789 5874 Internal Gain .................... n/a 1158 Ducts ............................ 1926 1891 Sensible Load .................... 21191 20803 Latent Load ...................... n/a 6241 Minimum Zone Load 21191 27044 Page 6 HVAC SIZING Date . 03/18/99 iect Title.......... Heritage, Plan 2B, Guest3 .. MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVal House UgPr#k-MP1657 User-Haynal and Company, Inc. Run-Typ ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating (Btuh) Opaque Conduction and Solar ...... 5137 925 Glazing Conduction ............... Glazing Solar .................... 2870 Infiltration ..................... n/a Internal Gain .................... 993 Ducts........................... Sensible Load .................... 10926 Latent Load ...................... n/a - Minimum Zone Load 10926 Cooling (Btuh) 2348 1875 2529 2165 359 928 10203 3061 13264 AC SIZING Page 7 HVAC -sect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume .. ..... ............ Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3476 sf 36807 cf Front Facing 180 deg PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 18993 10200 Glazing Conduction ............... 17885 17414 Glazing Solar .................... n/a 13373 Infiltration ..................... 19436 14659 Internal Gain .................... n/a 2607 Ducts ............................ 5631 5825 Sensible Load .................... 61945 64078 Latent Load ...................... n/a 19224 Minimum Total Load 61945 83302 (S) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designers responsibility to consider all factors when selecting the HVAC equipment. AC SIZING Page 8 HVAC erect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1397 sf Volume ........................... 16621 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7007 3888 Glazing Conduction ............... 11333 11035 Glazing Solar .................... n/a 6833 Infiltration ..................... 8777 6620 Internal Gain .................... n/a 1090 Ducts ............................ 2712 2946 Sensible Load .................... 29828 32411 Latent Load ...................... n/a 9723 Minimum Zone Load 29828 42135 ZONE 'SLEEPING' Floor Area ....................... 1475 sf Volume ........................... 14750 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6849 3963 Glazing Conduction ............... 4627 4505 Glazing Solar.................... n/a 5335 Infiltration ..................... 7789 5874 Internal Gain .................... n/a 1158 Ducts ............................ 1926 2084 Sensible Load .................... 21191 22919 Latent Load ...................... n/a 6876 Minimum Zone Load 21191 29794 'AC SIZING Page 9 HVAC -sect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 1925 1875 Glazing Solar .................... n/a 1206 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 359 Ducts ............................ 993 795 Sensible Load .................... 10926 8748 Latent Load ...................... n/a 2624 Minimum Zone Load 10926 11373 AC SIZING Page 10 HVAC erect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume .. ..... ............ Front Orientation.......... Sizing Location............ Latitude ... ...... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3476 sf 36807 cf Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 18993 10200 Glazing Conduction ............... 17885 17414 Glazing Solar .................... n/a 14926 Infiltration ..................... 19436 14659 Internal Gain .................... n/a 2607 Ducts ............................ 5631 5981 Sensible Load .................... 61945 65787 Latent Load ...................... n/a 19736 Minimum Total Load 61945 85522 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. rAC SIZING Page 11 HVAC sect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1397 sf Volume ........................... 16621 cf Heating Description (Btuh) Opaque Conduction and Solar...... 7007 Glazing Conduction ............... 11333 Glazing Solar .................... n/a Infiltration ..................... 8777 Internal Gain .................... n/a Ducts ............................ 2712 Sensible Load .................... 29828 Latent Load ...................... n/a Minimum Zone Load 29828 ZONE 'SLEEPING' Floor Area ....................... 1475 sf Volume ........................... 14750 cf Heating Description (Btuh) Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Zone Load Cooling (Btuh) 3888 11035 8933 6620 1090 3157 34722 10417 45138 Cooling (Btuh) 6849 3963 4627 4505 n/a 3464 7789 5874 n/a 1158 1926 1896 21191 20861 n/a 6258 21191 27120 AC SIZING Page 12 HVAC sect Title.......... Heritage, Plan 2B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT2G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating (Btuh) Cooling (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 1925 1875 Glazing Solar .................... n/a 2529 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 359 Ducts ............................ 993 928 Sensible Load .................... 10926 10203 Latent Load ...................... n/a 3061 Minimum Zone Load 10926 13264 Plan 3 CF-1R Page 1 03/17/99 OF COMPLIANCE: RESIDENTIAL Date..--. CCATE plan 3B ******* It # Heritage e Collection *v4 50* t Title.. The Her1tagCA CEA ******* Building Perm t Address.••••••' La Quinta, CEM, C eck Date Beth Brummitt, Inc. p an ;ntation Author. Haynal and Com"S Date 425 W 5th Ave Ste 201 C eck Escondido, CA 92025 Fie 760-743-5408 Standards by Enercomp, Inc. . 15 for 1995 to Zone .••••••• ..15CROPAS4 v4.50 CF-1R Wth-CTZ15S92 Program -FORM fiance Method ......MI ical House and Company, Inc. Run-TYP File- HERIT3 MICRr#-Mp165750User-Haynal User#- GENERAL INFORMATION 3100 sf Detached Floor Area. , • Single Family Conditioned ,,.. Building Type.... ' New _ N,g,S,W Cardinal Construction TYprientation• 1 Building Front Units•• Number of Dwelling 1 On Grade Number of Stories•• •e..., 24a5 a of floor area TYP Floor Constructioe 0 58 Btu/hr-sf-F Glazing Percentage Average Glazing U-value.••• INSULATION BUILDING SHELL Assembly Insul Comments R-value U-value Location/ Frame Cavity Sheathing )onent Type R-value R-value 0 To Garage type Y� R-17.8 Wood .049 R-17.8 R-4.68 R-22.48 0.025 R-38 Attic Wood L11 Wood R-17.8 R-38 Solid L11 R-11 R_n� R-0 0.330 To Outside )of n�ad R-0 R-n/a R-0 0.7 0 To Outside Dor R-0 R-n/a R-0 0.500 To Garage labEdge n�a R-0 R-n/a R-0 labEdge n/a R-0 labEdge FENESTRATION Over- hang/ Framing # of Interior Exterior Fins Type Pan- Shading/ Shading Area U- es Description Yes Wood (sf) Value None YeS Metal Orientation 50 2 None None None Metal Front (N) 48.0 0.550 2 None None Yes Metal Door (N) 18.0 0.720 2 None None Yes Metal Front Window Front (N) 85.4 0.530 2 None None Yes Metal Door Front (N) 16.0 0 600 2 None None Yes Metal Window E 34.0 0 2 None None Yes Metal Window Left ( ) 18.0 0.430 None None Yes Metal Window Left (E) 75.0 0.670 2 2 None None Yes Metal Window Left (E) 45.0 0.670 None None Yes Metal Window Back (S) p.600 2 None None Yes Metal S 145.0 0 530 Back ( ) 2 Window Back (S) 128.0 2 None None Yes None Door Back (S) 25.0 0.430 2 None None Yes Metal W ow 0.430 None TA Right (W) 30.0 0.570 2 None None None None Metal Window Right (W) 42.3 0.600 2 None Window Right (W) 24.0 0 •800 2 Skylight Harz Page 2 CF-1R RESIDENTIAL FICATE OF COMPLIANCE: Date ........ 03/17/99 Heritage, Plan 3B ,Ct Title ..•••••• Wth_CTZ15S92 Program-FORa1CHouse File-HERIT3 Inc. Run-TYP MICROPAS4 v4.50 nal and Company, User#-MP1657 User -Hay THERMAL MASS Area Thickness (sf) (in) Location/Comments Exposed Hearth,WetBa Type 3.5 Entry,Kitch, Yes Yes 371 3.5 Baths,Laundry S1abOnGrade 1196 112 3'S Covered S1abOnGrade No 3.5 Covered SlabOnGrade No 1422 S1abOnGrade HVAC SYSTEMS Duct Thermostat Minimum Duct R-value Type Location Equipment Type Efficiency R-4.2 LivingStat 0.800 AFUE Attic R-4 2 Livin�[Stat Furnace 12 00 SEER Attic R-4 2 S1eepingStat ACSplit 0.800 AFUE Attic R-4 2 Sleepingstat Furnace 12.00 SEER Attic ACSplit WATER HEATING SYSTEMS Tank External Number Energy Size Insulation in R-value e Distribution Type SystemFay (g- Lank Type Heater Type 1 52 EF 75 R-12 Gas Recirc/TimeTemp Storage SPECIAL FEATURES/REMARKS ation building with no Or restrictions. 'his is.'a multiple orientNorth. 'his printout is for the front facing Page 3 CF-1R rIFICATE OF COMPLIANCE: RESIDENTIAL ►Pct Title.......... Heritage, Plan 3B Date........ 03/17/99 oram-FORM 11— MICROPAMP165750User1File-HERIHaynalTandWCompany5SInc.PrRun-Typical`House COMPLIANCE STATEMENT 'his certificate of comp�oancomlists withthe Tbtlea24g Partsfeatures and and performance tithe specifications needed P ,alifornia Code to of Regulations, has been signedand thesbyathee individualnswith Lmplement them. This )verall design responsibility• lanetothisbcertifin icate oiflecorBentationsliancs submitted for a single building p any shading feature that is varied is indicated in the Special Features Remarks section. DOCUMENTATION AUTHOR DESIGNER or OWNER Name.... John Moore, Sr. Vice Pres Name a BethHaynBr mmittnd , , CEA CEMCEM, Inc. Company. Brookfield Homes Del Mar, 200 me.. Company. Address. 425 W th Ave Ste Address. 12865 Pointe Esconphone... 201 Del Mar, CA 92014 760-743-5408 Phone... 619-481-8500 License. 3 � Signed. Signed.. date e AGENCY Name... Title... Agency.. Phone... Signed.. date RPUTER METHOD SUMMARY Page 1 C-2R Heritage Plan 3B Date........ 03/17/99 ect Title.......... , ******* ect Address........ The Heritage Collection *v4.50* La Quinta, Building Permit :umentation Author... Beth Brummitt, CEM, CEA ******* g Haynal and Company, Inc. Plan Check Date 425 W 5th Ave Ste 201 Escondido, CA 92025 Fie C ec Date 760-743-5408 imate Zone........... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Use Standard Proposed Compliance sf-yr) Design Design Margin FEnergy Heating.......... 2.25 27.90 2.60 21.416.49 -0.35 Cooling.......... Heating.......... 8.43 8.14 0.29 North Total 38.58 32.15 6.43 Space Heating.......... 2.25 27.90 2.55 21.92 -0.30 5. 98 Space Water Cooling.......... Heating.......... 8.43 8.14 0.2299 East Total 38.58 32.61 5.97 Space Heating.......... 2.25 27.90 2.56 22.00 -0.31 5.90 Space Water Cooling.......... Heating.......... 8.43 8.14 0.29 South Total 38.58 32.70 5.88 Space Heating.......... 2.25 27.90 2.50 21.75 -0.25 6.15 Space Water Cooling.......... Heating.......... 8.43 8.14 0.29 West Total 38.58 32.39 6.19 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3100 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 2 Page 2 C-2R UTER METHOD SUMMARY Date........ 03/17/99 ect Title.......... Heritage, Plan 3B nany, Inc. Run -Typical House MICROPAS4 v4.50 d CompFile-HERITa Wth-TZ15S92 Program -FORM C- User#-MP1657 User-Haynal Volume. ......... • " " '. 31355 cf 3101 sf Footprint Area ............. 3101 sf Ground Floor Area....... Slab -On -Grade Area ......... 2405 sfof floor area Glazing Percentage....• 58 Btu/hr-sf-F Average Glazing U-value•••' 0.ft Average Ceiling Height..... BUILDING ZONE INFORMATION Vent Special Floor # of Thermostat Height Vent Area Area Volume Dwell Cond- (ft) (sf) ie Type (sf) (cf) Units itioned TYPe 3.8 n/a VING LivingStat 16770 0.51 Yes asidence 1566 n/a EEPING 1534 14585 0.49 Yes SleepingStat 3.2 esidence OPAQUE SURFACES Solar Form 3 Location/ Area U- Insul Act Comments irface (sf) value R-val Azm Tilt Gains Reference :,FG 169 0.049 22.48 0 90 Yes W.19.2X6.16F all 451 0.049 22.48 90 90 Yes W•19.2X6.16F Wall 181 0.049 22.48 180 90 Yes W.19.2X6.16F 7 Wall 55 0.049 22.48 270 90 Yes W.19.2X6.16F 8 Wall 15 5 0.025 38 n/a 0 Yes R.38.2X4.24 R-38 Attic 0 Roof LEEPING 289 0.061 17.8 0 90 No W.19.2X6.16G To Garage 1 Wall 73 0.049 2248 90 90 Yes W.19.2X6.16F 1. 2 Wall 66 0.049 22.48 180 90 Yes W.19.2X6.16F 3 Wall 527 0.049 22.48 270 90 Yes W.19.2X6.R-3Attic 4 Wall 10 0.025 38 n/a 0 Yes one X4.24 Soli Nd wood 9 Roof 21 015.330 0 0 90 No None L1 Door PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments Surface LIVING No To Outside 12 SlabEdge 28 0.0 R-0 No To Outside 13 SlabEdge 99 0.720 R-0 SLEEPING No To Outside 14 SlabEdge 2 0.900 R-0 No To Outside 15 SlabEdge 102 0.720 R-0 No To Garage 16 SlabEdge 35 0.500 R-0 Page 3 C-2R PUTER METHOD SUMMARY 03/17/99 'ect Title.......... Heritage, Plan 3B Date........ MICRr#-M v4.50User1HaynalTandWCompany, Inc.PrRun-TypiRcalCHouse User#-MP1657 Y FENESTRATION SURFACES SC SC Interior # of Area Pan- Frame Vent Open U- Act Tlt Glass Int Shading/ Only Shade Description face (sf) es Type Type value Azm DING Door 48.0 2 0.720 0 .78 None 90 0.88 0.78 None Window 18 Metal Meta 1 Std Std 0.530 0 go 0.47 0.78 None Door Window 85.4 2 16.0 Metal Std 0.430 0.430 0 90 90 0.47 0.78 None go 0.47 0.78 None Window 2 Metal Metal Std Std 0.670 90 90 0.66 0.78 None Window Window 30.00 30. 45.0 2 Metal Std 0.670 0.670 go 180 go 0.66 0.78 None 90 0.66 0.78 None Window 30.0 Metal Std Std Window Window 6002 15.0 Metal Std 0.6Metal �0 0.530 180 180 90 0.66 0.78 None go 0.47 0.78 None Door 02 Metal Metal Std Std 0.600 180 90 0.47 0.78 None Window Window 25.0 25 2500 2 Metal Std 0.430 0.430 180 2770 go 0.47 0.78 None 90 0.47 0.78 None Window 25. Metal Std .jEEPING Window 9. 2 Metal Std 0.600 0.600 90 90 go 0.47 0.78 None 90 0.47 0.78 None endow 25.0 Metal Metal Std Std 0.600 180 go 0.47 0.78 None indow 64.0 2 64.0 Metal Std 0.5330 180 90 0.47 0.78 None 7 Door B Window 30.0 2 Metal Std 0.570 270 90 0.88 0.78 None 0 Window 30.0 2 None Metal Std 0.600 270 90 0.47 0.78 None 1 Window 2 Window 6 0 2 6.3 Metal Std 0.600 0.600 270 270 90 0.47 0.78 None 90 01.00 3 Window 2 Metal Metal Std Std 0.72 None 4 Skylight 20.0 OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Wdth Left Dpth Hght Ext Rght Ext Ext Dpth Hght Ext Dpth Hght surface (sf) Hght .jIVING 1 Door 48.0 8 6 7.5 0 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 18.0 3 6 7.5 0 n/a 3 n/a n/a 4 Window 7 Window 16.0 1.5 18.0 1.5 11 12 1.5 n/a 3'S n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 30.0 7.5 7.5 4 6 0.5 10 . 0 3 0.5 0 1 4 4 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 10 Window 45.0 30.0 7.5 4 10 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 7.5 8 2 10 8.5 .5 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 15.0 64.0 8 64.0 8 8 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 11 'indow 25.0 5 5 8.5 8.5 .5 n/a n/a n/a I indow 25.0 5 5 19 •5 3/a O/a n/a n/a n/a n/a n/a n/a 19indow SLEEPING 25.0 5 3 5 3 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 9 0 5 1.5 1.5 n/a n/a n/a n/a n/a n/a 6 Window 25.0 5 qPUTER METHOD SUMMARY Page 4 C-2R *Pnt Title.......... Heritage, Plan 3B Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House OVERHANGS AND SIDE FINS Window- Overhang Area Left Rght rface (sf) Hght Wdth Dpth Hght Ext Ext Ext Window 30.0 7.5 4 8 .5 n/a n/a n/a n/a n/ n/ Door Window 64.0 30.0 8 7.5 8 4 8 8 .5 .5 n/a n/a n/ i Window 30.0 6 5 1.5 1.5 n/a n/a n/ Window 6.0 3 2 1.5 1.5 n/a n/a n/ Window 6.3 2.5 2.5 1.5 1.5 n/a 1.5 n/a n/a n/a n/ n/ Window 30.0 6 5 1.5 THERMAL MASS Area Thick Heat Conduct- Surface iss Type (sf) (in) Cap ivity R-value CVING L S1abOnGrade 371 3.5 28.0 0.98 3 S1abOnGrade 1196 3.5 28.0 0.98 ' `'APING ;;labOnGrade 112 3.5 28.0 0.98 f SlabOnGrade 1422 3.5 28.0 0.98 Left Fin Right Fin- Dpth Hght Ext Dpth Hght a n/a n/a n/a n/a n/a a n/a n/a n/a n/a n/a a n/a n/a n/a n/a n/a a n/a n/a n/a n/a n/a a n/a n/a n/a n/a n/a a n/a n/a n/a n/a n/a a n/a n/a n/a n/a n/a Location/Comments R-0.0 Entry,Kitch,Hearth,WetBar R-2.0 Covered R-0.0 Baths,Laundry R-2.0 Covered HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 SLEEPING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) 1 Storage Gas Recirc/TimeTemp 1 .52 75 SPECIAL FEATURES/REMARKS External Insulation R-value R-12 'his is a multiple orientation building with no orientation restrictions. 'his printout is for the front facing North. Location/Comments R-0.0 Entry,Kitch,Hearth,WetBar R-2.0 Covered R-0.0 Baths,Laundry R-2.0 Covered HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 SLEEPING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) 1 Storage Gas Recirc/TimeTemp 1 .52 75 SPECIAL FEATURES/REMARKS External Insulation R-value R-12 'his is a multiple orientation building with no orientation restrictions. 'his printout is for the front facing North. WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) 1 Storage Gas Recirc/TimeTemp 1 .52 75 SPECIAL FEATURES/REMARKS External Insulation R-value R-12 'his is a multiple orientation building with no orientation restrictions. 'his printout is for the front facing North. Calculation for Ventilation Height Heritage: Plan 3 Gross Weighted Opening Gross Effective Vent Vent Area Horizontal Center Vent Area * Average Height Area 00 Area Inlet Outlet Inlet Outlet Height Height Height SLEEPING ZONE: Sliding windows/doors 0.1 0 0 0 3030 3 9 0.1 0.9 0.45 0.45 0.75 2.25 1.5 13.5 5050 5 25 0.1 2.5 1.25 1.25 1.25 3.75 2.5 62.5 4076 7.5 30 0.1 3 1.5 1.5 1.875 5.625 3.75 112.5 8080 8 64 0.1 6.4 3.2 3.2 2 6 4 256 4076 7.5 30 0.1 3 1.5 1.5 1.875 5.625 3.75 112.5 3020 2 6 0.1 0.6 0.3 0.3 0.5 1.5 1 6 2626 2.5 6.25 0.1 0.625 0.3125 0.3125 0.625 1.875 1.25 7.8125 6050 5 30 0.1 3 1.5 1.5 1.25 3.75 2.5 75 Hinged windows/doors 0 0.2 0 0 0 0 0 0 0 none Total Operable 200.25 20.025 10.0125 10.0125 645.81251 3.2 Fixed windows 0 0 GB-6050 n/a 30 Total Sleeping 230.25 / LIVING ZONE: Sliding windows/doors 0.1 0 0 0 24076 7.5 60 0.1 6 3 3 1.875 5.625 3.75 225 8080 8 64 0.1 6.4 3.2 3.2 2 6 4 256 5050 5 25 0.1 2.5 1.25 1.25 1.25 3.75 2.5 62.5 Hinged windows/doors 0 0.2 0 0 0 0 0 0 0 6080 8 48 0.2 9.6 4.8 4.8 2 6 4 192 5480 8 42.6 0.2 8.52 4.26 4.26 2 6 4 170.4 5480 8 42.6 0.2 8.52 4.26 4.26 2 6 4 170.4 TotalOperable 282.2 41.54 20.77 20.77 1076.31 3.8 Fixed windows 0.0 0 transoms n/a 34.0 4-3016 n/a 18.0 2-4076 n/a 60.0 6076 n/a 45.0 2076 n/a 15.0 5050 n/a 25.0 5050 n/a 25.0 Total Living 504.2 TOTAL Fenestration 734.5 heritage cr / Vent Height Plan 3 3/19/99 Plan 3 with Guest 2 G �J RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R ect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 jct Address........ The Heritage Collection ******* La Quinta, CA *v4.50* cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit # Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date imate Zone........... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Stories. ........ Floor Construction Type.... Glazing Percentage......... Average Glazing U-value.... 3536 sf Single Family Detached New Cardinal - N,E,S,W 1 1 Slab On Grade 23.3 % of floor area 0.57 Btu/hr-sf-F BUILDING SHELL INSULATION Frame Cavity Sheathing Insul Assembly 9onent pe Type R-value R-value R-value U-value Location/Comments all Wood R-17.8 R-0 R-17.8 0.061 To Garage ill Wood R-17.8 R-4.68 R-22.48 0.049 )of Wood R-11 R-27 R-38 0.025 R-38 Attic )or n/a R-0 R-n/a R-0 0.330 Solid Wood LabEdge n/a R-0 R-n/a R-0 0.900 To Outside LabEdge n/a R-0 R-n/a R-0 0.720 To Outside LabEdge n/a R-0 R-n/a R-0 0.500 To Garage FENESTRATION rientation Area U- (sf) Value # of Interior Over- Pan- Shading/ Exterior hang/ Framing es Description Shading Fins Type oor Front (N) 48.0 0.550 2 None None Yes Wood indow Front (N) 18.0 0.720 2 None None Yes Metal c)or Front (N) 85.4 0.530 2 None None None Metal indow Front (N) 16.0 0.430 2 None None Yes Metal indow Left (E) 34.0 0.600 2 None None Yes Metal indow Left (E) 18.0 0.430 2 None None Yes Metal indow Left (E) 75.0 0.670 2 None None Yes Metal indow Back (S) 45.0 0.670 2 None None Yes Metal indow Back (S) 145.0 0.600 2 None None Yes Metal oor Back (S) 128.0 0.530 2 None None Yes Metal indow Back (S) 25.0 0.430 2 None None Yes Metal ow Right (W) 25.0 0.430 2 None None Yes Metal ow Right (W) 30.0 0.570 2 None None Yes None indow Right (W) 42.3 0.600 2 None None Yes Metal indow Left (E) 6.0 0.600 2 None None None Metal r2TIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R 9iect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Area U- ientation (sf) value for Back (S) 45.0 0.530 .ndow Right (W) 8.0 0.430 .ndow Right (W) 6.0 0.570 :ylight Horz 24.0 0.800 Type Exposed FENESTRATION # of Interior Pan- Shading/ es Description S1abOnGrade Yes S1abOnGrade Yes S1abOnGrade No S1abOnGrade No S1abOnGrade No Exterior Shading 2 None None 2 None None 2 None None 2 None None THERMAL MASS Over- hang/ Framing Fins Type None Metal None Metal None None None Metal Area Thickness (sf) (in) Location/Comments 371 3.5 Entry,Kitch,Hearth,WetBa 112 3.5 Baths,Laundry 1196 3.5 Covered 1422 3.5 Covered 436 3.5 Covered HVAC SYSTEMS Minimum Duct Equipment Type Efficiency Location Duct Thermostat R-value Type Furnace 0.800 AFUE Attic R-4.2 ACSplit 12.00 SEER Attic R-4.2 Furnace 0.800 AFUE Attic R-4.2 ACSplit 12.00 SEER Attic R-4.2 Furnace 0.800 AFUE Attic R-4.2 ACSplit 12.00 SEER Attic R-4.2 WATER HEATING SYSTEMS Tank Type Heater Type Distribution Type Storage Gas Recirc/TimeTemp Number in System 1 SPECIAL FEATURES/REMARKS LivingStat LivingStat SleepingStat SleepingStat SleepingStat SleepingStat Tank External Energy Size Insulation Factor (gal) R-value .52 EF 75 R-12 'his is a multiple orientation building with no orientation restrictions. 'his printout is for the front facing North. 'IFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-iR sect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3G2 Wth-CTyl5 92 Program -FORM House TTcPr#k-MP1657 User-Haynal and Com an , Inc. Run-Typic COMPLIANCE STATEMENT and his certificate of comp�oancomllytwitheTbitle-24g Partsrls and performance 6rfof tithe pecifications needed P regulations to alifornia Code of Regulations, and the administrative mplement them. This certificate When thisscertafbcateeofindompliancewlis iverall design responsibility. plan to be built in multiple orientations, ;ubmitted for a single building p Lny shading feature that is varied is indicated in the Special Features >Pmarks section. DESIGNER or OWNER Jame.... John Moore, Sr. Vice �ompany. Brookfield Homes kddress. 12865 Pointe Del Mar, Del Mar, CA 92014 Phone... 619-481-8500 License. // Signed. CEMENT AGENCY Name.. Title... Agency.. Phone... DOCUMENTATION AUTHOR Pres Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. 200 Address Ave 5te 1 Escondido, CA 92025 Phone... 760-743-5408 Signed.. 4k-3 17 date Signed.. date APUTER METHOD SUMMARY Page 1 C-2R ect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 ct Address........ The Heritage Collection ******* La Quinta, CA *v4.50* cumentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. 425 W 5th Ave Ste 201 Plan Check Date Escondido, CA 92025 760-743-5408 Field C ec Date imate Zone........... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM C-2R I User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.62 2.77 -0.15 Space Cooling.......... 28.88 21.34 7.54 Water Heating.......... 7.39 7.13 0.26 North Total 38.89 31.24 7.65 Space Heating.......... 2.62 2.85 -0.23 Space Cooling.......... 28.88 21.78 7.10 Water Heating.......... 7.39 7.13 0.26 East Total 38.89 31.76 7.13 Space Heating.......... 2.62 2.91 -0.29 Space Cooling.......... 28.88 21.70 7.18 Water Heating.......... 7.39 7.13 0.26 South Total 38.89 31.74 7.15 Space Heating.......... 2.62 2.71 -0.09 Space Cooling.......... 28.88 21.65 7.23 Water Heating.......... 7.39 7.13 0.26 West Total 38.89 31.49 7.40 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3536 sf Single Family Detached New Cardinal - N,E,S,W 1 ReducedYear Slab On Grade 3 KPUTER METHOD SUMMARY Page 2 C-2R --sect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Conditioned Volume......... 35279 cf Footprint Area ............. 3537 sf Ground Floor Area.......... 3537 sf Slab -On -Grade Area......... 3537 sf Glazing Percentage......... 23.3 It of floor area Average Glazing U-value.... 0.57 Btu/hr-sf-F Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor Area Volume ine Type (sf) (cf) VING # of Dwell Cond- Thermostat Units itioned Type :esidence 1566 16770 0.44 Yes ,EEPING :esidence 1534 14585 0.44 Yes TEST :esidence 436 3924 0.13 Yes Area ace (sf) CVING i Wall 169 3 Wall 451 7 Wall 181 3 Wall 55 1 Roof 1566 EEPING L Wall 289 Z Wall 173 3 Wall 66 4 Wall 527 3 Roof 1510 6 Door 21 [JEST 9 Wall 153 0 Wall 228 1 Wall 108 2 Wall 220 5 Roof 436 Surface OPAQUE SURFACES Vent Special Height Vent Area (ft) (sf) LivingStat 3.8 n/a SleepingStat 3.2 n/a SleepingStat 2.0 n/a U- Insul Act Solar Form 3 value R-val Azm Tilt Gains Reference 0.049 22.48 0 90 Yes 0.049 22.48 90 90 Yes 0.049 22.48 180 90 Yes 0.049 22.48 270 90 Yes 0.025 38 n/a 0 Yes 0.061 17.8 0 90 No 0.049 22.48 90 90 Yes 0.049 22.48 180 90 Yes 0.049 22.48 270 90 Yes 0.025 38 n/a 0 Yes 0.330 0 0 90 No 0.049 22.48 0 90 Yes 0.049 22.48 90 90 Yes 0.049 22.48 180 90 Yes 0.049 22.48 270 90 Yes 0.025 38 n/a 0 Yes PERIMETER LOSSES Length F2 Insul (ft) Factor R-val LIVING 17 S1abEdge 28 0.900 R-0 No To Outside 18 S1abEdge 99 0.720 R-0 No To Outside SLEEPING 19 SlabEdge 2 0.900 R-0 No To Outside Location/ Comments W.19.2X6.16F W.19.2X6.16F W.19.2X6.16F W.19.2X6.16F R.38.2X4.24 R-38 Attic W.19.2X6.16G To Garage W.19.2X6.16F W.19.2X6.16F W.19.2X6.16F R.38.2X4.24 R-38 Attic None Solid Wood W.19.2X6.16F W.19.2X6.16F W.19.2X6.16F W.19.2X6.16F R.38.2X4.24 R-38 Attic Solar Gains Location/Comments 4PUTER METHOD SUMMARY Page 3 C-2R ;,ect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Surface 20 SlabEdge 21 SlabEdge GUEST 22 SlabEdge 23 SlabEdge xface RING Door Window s Door 6 Window 7 Window Sindow indow Window L Window Window 3 Door 4 Window 5 Window 9 Window LEEPING 5 Window 6 Window 6 Window 7 Door 8 Window 0 Window 1 Window 2 Window 3 Window 8 Skylight UEST 4 Window 5 Door 6 Window 7 Window Area (sf) PERIMETER LOSSES Length F2 (ft) Factor Insul R-val Solar Gains Location/Comments 102 0.720 R-0 No To Outside 35 0.500 R-0 No To Garage 10 0.900 R-0 No To Outside 76 0.720 R-0 No To Outside FENESTRATION SURFACES # of Frame Vent Open U- Act SC SC Interior Glass Int Shading/ Pan- es Type Type value Azm Tlt Only Shade Description 48.0 2 Wood Std 0.550 0 90 0.88 0.78 None 18.0 2 Metal Std 0.720 0 90 0.88 0.78 None 85.4 2 Metal Std 0.530 0 90 0.47 0.78 None 16.0 2 Metal Std 0.430 0 90 0.47 0.78 None 18.0 2 Metal Std 0.430 90 90 0.47 0.78 None 30.0 2 Metal Std 0.670 90 90 0.66 0.78 None 45.0 2 Metal Std 0.670 90 90 0.66 0.78 None 30.0 2 Metal Std 0.670 180 90 0.66 0.78 None 60.0 2 Metal Std 0.600 180 90 0.47 0.78 None 15.0 2 Metal Std 0.670 180 90 0.66 0.78 None 64.0 2 Metal Std 0.530 180 90 0.47 0.78 None 25.0 2 Metal Std 0.600 180 90 0.47 0.78 None 25.0 2 Metal Std 0.430 180 90 0.47 0.78 None 25.0 2 Metal Std 0.430 270 90 0.47 0.78 None 9.0 2 Metal Std 0.600 90 90 0.47 0.78 None 25.0 2 Metal Std 0.600 90 90 0.47 0.78 None 30.0 2 Metal Std 0.600 180 90 0.47 0.78 None 64.0 2 Metal Std 0.530 180 90 0.47 0.78 None 30.0 2 Metal Std 0.600 180 90 0.47 0.78 Ndne 30.0 2 None Std 0.570 270 90 0.88 0.78 None 6.0 2 Metal Std 0.600 270 90 0.47 0.78 None 6.3 2 Metal Std 0.600 270 90 0.47 0.78 None 30.0 2 Metal Std 0.600 270 90 0.47 0.78 None 24.0 2 Metal Std 0.800 0 0 0.72 1.00 None 6.0 2 Metal Std 0.600 90 90 0.47 0.78 None 45.0 2 Metal Std 0.530 180 90 0.47 0.78 None 8.0 2 Metal Std 0.430 270 90 0.47 0.78 None 6.0 2 None Std 0.570 270 90 0.88 0.78 None MPUTER METHOD SUMMARY Page 4 C-2R ect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght .rface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght VING Door 48.0 8 6 7.5 0 n/a n/a n/a n/a n/a n/a n/a n/a Window 18.0 3 6 7.5 0 n/a n/a n/a n/a n/a n/a n/a n/a Window 16.0 1.5 11 3 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 18.0 1.5 12 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 30.0 7.5 4 3 0.5 10 1 n/a n/a n/a n/a n/a n/a Window 45.0 7.5 6 18 0.5 0 4 n/a n/a n/a n/a n/a n/a i Window 30.0 7.5 4 10 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 60.0 7.5 8 10 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 15.0 7.5 2 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Door 64.0 8 8 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 25.0 5 5 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 25.0 5 5 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 25.0 5 5 19 .5 3 0 n/a n/a n/a n/a n/a n/a JEEPING i Window 9.0 3 3 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a i Window 25.0 5 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a )endow 30.0 7.5 4 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a oor 64.0 8 8 8 .5 n/a n/a n/a n/a n/a n/a n/a 3 Window 30.0 7.5 4 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a Window 30.0 6 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a L Window 6.0 3 2 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a Window 6.3 2.5 2.5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 30.0 6 5 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface ).ss Type (sf) (in) Cap ivity R-value Location/Comments CVING L S1abOnGrade 371 3.5 28.0 0.98 R-0.0 Entry,Kitch,Hearth,WetBar 3 S1abOnGrade 1196 3.5 28.0 0.98 R-2.0 Covered =PING Z S1abOnGrade 112 3.5 28.0 0.98 R-0.0 Baths,Laundry 4 SlabOnGrade 1422 3.5 28.0 0.98 R-2.0 Covered JEST 5 S1abOnGrade 436 3.5 28.0 0.98 R-2.0 Covered HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R-value Efficiency LIVING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 SLEEPING Furnace 0.800 AFUE Attic R-4.2 0.830 ACSplit 12.00 SEER Attic R-4.2 0.810 )MPUTER METHOD SUMMARY Page 5 C-2R j,,ect Title.......... Heritage, Plan 3B, Guest2 Date........ 03/17/99 MICROPAS4 v4.50 File-HERIT3G2 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House System Type GUEST Furnace ACSplit HVAC SYSTEMS Minimum Efficiency Duct Duct Duct Location R-value Efficiency 0.800 AFUE Attic 12.00 SEER Attic WATER HEATING SYSTEMS R-4.2 0.830 R-4.2 0.810 Number Tank External rank Type Heater Type Distribution Type in Energy System Factor Size (gal) Insulation R-value 1 Storage Gas Recirc/TimeTemp 1 .52 75 R-12 SPECIAL FEATURES/REMARKS ais is a multiple orientation building with his printout is for the front facing North. no orientation restrictions. Plan 3 with Guest 3 e 1 CF-1R ZTIFICATE OF COMPLIANCE: RESIDENTIAL Page Heritage Plan 3B, Guest3 Date........ 03/18/99 ect Title.......... I ******* ect Address........ The Heritage Collection *v4.50* La Quinta, CA �umentation Author... Beth Brummitt, CEM, CEA ******* Building Permit Haynal and Company, Inc. Plan C ec Date 425 W 5th Ave Ste 201 Escondido, CA 92025 Field C ec Date 760-743-5408 imate Zone........... 15 mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program -FORM CF-1R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories. ...... Floor Construction Type.... Glazing Percentage......... Average Glazing U-value..., 3704 sf Single Family Detached New Cardinal - N,E,S,W 1 1 Slab On Grade 23.1 % of floor area 0.57 Btu/hr-sf-F BUILDING SHELL INSULATION �onent Frame Cavity Sheathing Insul Assembly pe Type R-value R-value R-value U-value Location/Comments all Wood R-17.8 R-0 R-17.8 0.061 To Garage all Wood R-17.8 R-4.68 R-27 R-22.48 R-38 0.049 0.025 R-38 Attic oof Wood n/a R-11 R-0 R-n/a R-0 0.330 Solid Wood ,00r labEdge n/a R-0 R-n/a R-0 0.900 To Outside outside ,labEdg n/a R-0 R-n/a R-0 0.500 To Garage labEdge FENESTRATION # of Interior Area U- Pan- Shading/ Exterior )rientation (sf) Value es Description Shading )oor window )oor Rindow Nindow Window Window Window Window Door Window T. Aow ow Window window Front Front Front Front Left Lef t Left Back Back Back Back Right Right Right Front (N) (N) (N) (N) (E) (E) (E) (S) (S) (S) (S) (W) (W) (W) (N) 48.0 18.0 85.4 16.0 34.0 18.0 75.0 45.0 145.0 128.0 25.0 25.0 30.0 42.3 30.0 0.550 0.720 0.530 0.430 0.600 0.430 0.670 0.670 0.600 0.530 0.430 0.430 0.570 0.600 0.600 2 2 2 2 2 2 2 2 2 2 2 2 2 2 None None None None None None None None None None None None None None None None None None None None None None None None None None None None None None Over- hang/ Fins Yes Yes None Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes None Framing Type Wood Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal None Metal Metal TIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-iR sect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 i MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-iOR� House TTser#-MP1657 User-Haynal and Company, Inc. Run -Typical ientation ndow Front (N) ndow Left (E) or Back (S) ndow Right (W) ylight Horz Type S1abOnGrade S1abOnGrade S1abOnGrade S1abOnGrade S1abOnGrade FENESTRATION ## of Interior Area U- Pan- Shading/ (sf) Value es Description 4.5 0.430 2 None 8.0 0.430 2 None 45.0 0.530 2 None 8.0 0.430 2 None 24.0 0.800 2 None THERMAL MASS Area Thickness Exposed (sf) (in) Yes 371 3.5 Yes 112 3.5 No 1196 3.5 No 1422 3.5 No 604 3.5 HVAC SYSTEMS Over - Exterior hang/ Framing Shading Fins Type None None Metal None None Metal None None Metal None None Metal None None Metal Location/Comments Entry,Kitch,Hearth,WetBa Baths,Laundry Covered Covered Covered Minimum Duct Duct Thermostat Equipment Type Efficiency Location R-value Type Furnace 0.800 AFUE Attic Attic R-4.2 R-4.2 Setback Setback ACSplit 12.00 SEER 0.800 AFUE Attic R-4.2 Setback Furnace ACSplit 12.00 SEER Attic R-4.2 R-4.2 Setback Setback Furnace 0.800 AFUE 12.00 SEER Attic Attic R-4.2 Setback ACSplit WATER HEATING SYSTEMS Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) External Insulation R-value DHW1 1 .52 EF 75 R-12 Storage Gas Recirc/TimeTemp DHW2 1 .535 EF 40 R-12 Storage Gas Standard SPECIAL FEATURES/REMARKS Phis is a multiple orientation building with no orientation restrictions. Phis printout is for the front facing North. ZTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R o� ect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 i MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program -OR i House User#-MP1657 User-Haynal and Company, Inc. Run -Typical COMPLIANCE STATEMENT This certificate of compliance lists eTbuilding feaPartures and s I and perfof athe specifications needed to comply with California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. Name.... Company. Address. Phone... License Signed. Name... Title.. Agency. Phone... DESIGNER or OWNER John Moore, Sr. Vice Brookfield Homes 12865 Pointe Del Mar, Del Mar, CA 92014 619-481-8500 Pres 200 Signed.. date DOCUMENTATION AUTHOR Name.... Beth Brummitt, CEM, CEA Company. Haynal and Company, Inc. Address. 425 W 5th Ave Ste 201 Escondido, CA 92025 Phone... 760-743-5408 Signed.. 3 1�" da e PUTER METHOD SUMMARY Page 1 C-2R 1 Heritage Plan 3B, Guest3 Date........ 03/18/99 ect Tit ........... ******* ct Address........ The Heritages Collection *v4.50* La Quinta, CA ;umentation Author... Beth Brummitt, CEM, CEA ******* Building Permit # Haynal and Company, Inc. Plan Check Date 425 W 5th Ave Ste 201 Escondido, CA 92025 Fie C ec Date 760-743-5408 Lmate Zone........... 15 npliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 2.67 28.92 2.83 23.92 -0.16 5.00 Space Water Cooling.......... Heating.......... 7.05 8.68 -1.63 North Total 38.64 35.43 3.21 Space Heating.......... 2.67 28.92 2.87 24.54 -0.20 4.38 Space Water Cooling.......... Heating.......... 7.05 8.68 -1.63 East Total 38.64 36.09 2.55 Space S P g.......... Heating 2.67 28.92 2.86 24.33 -0.19 4.59 Space Water Cooling.......... Heating.......... 7.05 8.68 -1.63 South Total 38.64 35.87 2.77 Space P g.......... Heating 2.67 28.92 2.81 24.75 -0.14 4.17 Space Water Cooling.......... Heating.......... 7.05 8 68 -1.17 63 West Total 38.64 36.24 2.40 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... 3704 sf Single Family Detached New Cardinal - N,E,S,W 1 1 ReducedYear Slab On Grade 3 MPUTER METHOD SUMMARY Page 2 C-2R -Zect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House -)ne Tvoe EVING residence LEEPING Residence [JEST Residence dace IVING 5 Wall 6 Wall 7 Wall 8 Wall .4 Roof LEEPING 1 Wall 2 Wall 3 Wall 4 Wall _3 Roof .6 Door ,UEST 9 Wall LO Wall L1 Wall L2 Wall L5 Roof Conditioned Volume......... 36791 cf Footprint Area ............. 3705 sf Ground Floor Area.......... 3705 sf Slab -On -Grade Area......... 3705 sf Glazing Percentage......... 23.1 % of floor area Average Glazing U-value.... 0.57 Btu/hr-sf-F Average Ceiling Height..... 9.9 ft BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- Thermostat (sf) (cf) Units itioned Type Surface Vent Special Height Vent Area (ft) (sf) 1566 16770 0.42 Yes Setback 3.8 n/a 1534 14585 0.41 Yes Setback 3.2 n/a 604 5436 0.17 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ (sf) value R-val Azm Tilt Gains Reference Comments 169 0.049 22.48 0 90 Yes W.19.2X6.16F 451 0.049 22.48 90 90 Yes W.19.2X6.16F 181 0.049 22.48 180 90 Yes W.19.2X6.16F 55 0.049 22.48 38 270 n/a 90 Yes 0 Yes W.19.2X6.16F R.38.2X4.24 R-38 Attic 1566 0.025 289 0.061 17.8 0 90 No W.19.2X6.16G To Garage 173 0.049 22.48 90 90 Yes W.19.2X6.16F 66 0.049 22.48 180 90 Yes W.19.2X6.16F 527 0.049 22.48 270 n/a 90 Yes 0 Yes W.19.2X6.16F R.38.2X4.24 R-38 Attic 1510 21 0.025 0.330 38 0 0 90 No None Solid Wood 155 0.049 22.48 0 90 Yes W.19.2X6.16F 289 0.049 22.48 90 90 Yes W.19.2X6.16F 144 0.049 22.48 180 90 Yes W.19.2X6.16F 289 0.049 22.48 270 90 Yes 0 Yes W.19.2X6.16F R.38.2X4.24 R-38 Attic 604 0.025 38 n/a PERIMETER LOSSES LIVING 17 SlabEdge 18 SlabEdge SLEEPING 19 SlabEdge Length (ft) F2 Factor Insul R-val Solar Gains Location/Comments 28 0.900 R-0 No To Outside 99 0.720 R-0 No To Outside 2 0.900 R-0 No To Outside PUTER METHOD SUMMARY Page 3 C-2R erect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program -FORM User#-MP1657 User-Haynal and Company, Inc. Run -Typical House Surface 20 S1abEdge 21 S1abEdge GUEST 22 S1abEdge rf ace VING Door Window Door Window Window Window `indow Xindow Window >. Window 3 Door i Window Window Window LEEPING 5 Window 6 Window 6 Window 7 Door 8 Window 0 Window 1 Window 2 Window 3 Window 9 Skylight UEST 4 Window 5 Window ,6 Window 7 Door 8 Window Area (sf) PERIMETER LOSSES Length F2 Insul R-val Solar Gains Location/Comments (ft) Factor 102 0.720 R-0 No To Outside 35 0.500 R-0 No To Garage 108 0.720 R-0 No To Outside FENESTRATION SURFACES # of Vent Act SC SC Interior Glass Int Shading/ Pan- Frame Type Open U- Type value Azm Tlt Only Shade Description es 48.0 2 Wood Std 0.550 0 0 90 90 0.88 0.88 0.78 None 0.78 None 18.0 2 Metal Metal Std Std 0.720 0.530 0 90 0.47 0.78 None 85.4 16.0 2 2 Metal Std 0.430 0 90 0.47 0.78 None 18.0 2 Metal Std 0.430 90 90 90 90 0.47 0.66 0.78 0.78 None None 30.0 2 Metal Metal Std Std 0.670 0.670 90 90 0.66 0.78 None 45.0 30.0 2 2 Metal Std 0.670 180 90 90 0.66 0.47 0.78 0.78 None None 60.0 2 Metal Metal Std Std 0.600 0.670 180 180 90 0.66 0.78 None 15.0 64.0 2 2 Metal Std 0.530 180 90 90 0.47 0.47 0.78 0.78 None None 25.0 2 Metal Std Std 0.600 0.430 180 180 go 0.47 0.78 None 25.0 25.0 2 2 Metal Metal Std 0.430 270 90 0.47 0.78 None 9.0 2 Metal Std 0.600 90 90 90 90 0.47 0.47 0.78 0.78 None None 25.0 2 Metal Metal Std Std 0.600 0.600 180 90 0.47 0.78 None 30.0 64.0 2 2 Metal Std 0.530 180 90 0.47 0.78 None 30.0 2 Metal Std 0.600 180 270 90 90 0.47 0.88 0.78 0.78 None None 30.0 2 None Metal Std Std 0.570 0. 600 270 90 0.47 0.78 None 6.0 6.3 2 2 Metal Std 0.600 270 90 0.47 0.78 None 30.0 2 Metal Std 0.600 270 o 90 0.47 0.72 .78 �.00 None None 24.0 2 Metal Std 0.800 30.0 2 Metal Std 0.600 0 0 90 90 0.47 0.47 0.78 0.78 None None 4.5 2 Metal Metal Std Std 0.430 0.430 90 90 0.47 0.78 None 8.0 48.0 2 Std 0.530 180 go 90 0.47 0.47 0.78 0.78 None None 2 Metal Std 0.430 270 4PUTER METHOD SUMMARY Page 4 C-2R ect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Inc. Program -FORM Run -Typical C-2R House User#-MP1657 User-Haynal and Company, OVERHANGS AND SIDE FINS Window- --Overhang Left Fin Right Fin - rface Area (sf) Hght Wdth Left Dpth Hght Ext Rght Ext Ext Dpth Hght Ext Dpth Hght VING Door 48.0 8 6 7.5 0 n/a 0 n/a n/a n/a n/a n/ a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Window Window 8.0 3 16.0 1.5 6 11 7.5 3 1.5 n/a 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Window Window 18.0 1.5 30.0 7.5 12 4 1.5 3 0.5 10 1 4 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a i Window I Window 45.0 7.5 30.0 7.5 6 4 18 0.5 0 10 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Window >. Window 60.0 7.5 15.0 7.5 8 2 10 .5 n/a 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 6 Window 64.0 8 25.0 5 8 5 8.5 .5 n/a 8.5 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 25.0 5 5 8.5 .5 n/a 19 3 n/a 0 n/a n/a n/a n/a n/a n/a n/a n/a a Window 25.0 5 5 .5 JEEPING Window 9.0 3 3 1.5 1.5 n/a 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 5 Window endow 1oor 25.0 5 25.0 7.5 5 4 1.5 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a B Window 64.0 8 30.0 7.5 8 4 8 .5 8 .5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 0 Window 30.0 6 3 5 2 1.5 1.5 n/a 1.5 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 1 Window 2 Window 6.0 6.3 2.5 2.5 1.5 1.5 n/a 1.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 30.0 6 5 1.5 THERMAL MASS Area (sf) Thick Heat Conduct- (in) Cap ivity Surface R-value Location/Comments ass Type DIVING 1 S1abOnGrade 371 3.5 28.0 0.98 R-0.0 Entry,Kitch,Hearth,WetBar 3 SlabOnGrade 1196 3.5 28.0 0.98 R-2.0 Covered LEEPING 2 S1abOnGrade 112 3.5 28.0 0.98 R-0.0 Baths,Laundry Covered 4 S1abOnGrade 1422 3.5 28.0 0.98 R-2.0 J5ES1abOnGrade 604 3.5 28.0 0.98 R-2.0 Covered HVAC SYSTEMS System Type Minimum Duct Efficiency Location Duct Duct R-value Efficiency LIVING Furnace 0.800 AFUE Attic Attic R-4.2 R-4.2 0.830 0.810 ACSplit 12.00 SEER SLEEPING Furnace 0.800 AFUE Attic Attic R-4.2 R-4.2 0.830 0.810 ACSplit 12.00 SEER MPUTER METHOD SUMMARY Page 5 C-2R erect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program -FORM C-2R User#-MP1657 User-Haynal and Company, Inc. Run -Typical House System Type HVAC SYSTEMS Minimum Duct Efficiency Location GUEST Furnace 0.800 AFUE Attic ACSplit 12.00 SEER Attic WATER HEATING SYSTEMS 'ank Type Duct Duct R-value Efficiency R-4.2 0.830 R-4.2 0.810 Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R-value )HW1 1 Storage Gas Recirc/TimeTemp 1 .52 75 R-12 )HW2 2 Storage Gas Standard 1 .535 40 R-12 SPECIAL FEATURES/REMARKS As is a multiple orientation building with no orientation restrictions. k printout is for the front facing North. A Plan 3 HVAC Loads 'AC SIZING Page 1 HVAC —iect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 ******* pct Address........ The Heritage Collection La Quinta, CA *v4.50* �cumentation Author... Beth Brummitt, CEM, CEA ******* Haynal and Company, Inc. 425 W 5th Ave Ste 201 Escondido, CA 92025 760-743-5408 t Z 15 �ma a one. .. ..... )mpliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. 3704 sf Volume .. ..... ............ 36791 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ PALM DESERT Latitude... .... ........ 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 75 F Summer Range . ...... ...... 34 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 19142 10068 Glazing Conduction ............... 18570 18082 Glazing Solar .................... n/a 13366 Infiltration ..................... 19427 14653 Internal Gain .................... n/a 2614 Ducts ............................ 5714 5878 Sensible Load .................... 62854 64661 Latent Load ...................... n/a 19398 Minimum Total Load 62854 84059 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designers responsibility to consider all factors when selecting the HVAC equipment. 'AC SIZING Page 2 HVAC -i,ect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1566 sf Volume ........................... 16770 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6712 3642 Glazing Conduction ............... 10870 10584 Glazing Solar .................... n/a 4836 Infiltration ..................... 8855 6679 Internal Gain .................... n/a 1145 Ducts ............................ 2644 2689 Sensible Load .................... 29082 29574 Latent Load ...................... n/a 8872 Minimum Zone Load 29082 38446 ZONE 'SLEEPING' Floor Area ....................... 1534 sf Volume ........................... 14585 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7293 4078 Glazing Conduction ............... 5775 5623 Glazing Solar .................... n/a 7251 Infiltration ..................... 7702 5809 Internal Gain .................... n/a 1131 Ducts ............................ 2077 2389 Sensible Load .................... 22846 26281 Latent Load ...................... n/a 7884 Minimum Zone Load 22846 34165 AC SIZING Page 3 HVAC Vct Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 1925 1875 Glazing Solar .................... n/a 1279 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 338 Ducts ............................ 993 801 Sensible Load .................... 10926 8806 Latent Load ...................... n/a 2642 Minimum Zone Load 10926 11448 AC SIZING Page 4 HVAC _Vct Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume ..................... Front Orientation.......... Sizing Location............ Latitude... .. ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... 3704 sf 36791 cf Front Facing 90 deg PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 19142 10068 Glazing Conduction ............... 18570 18082 Glazing Solar .................... n/a 13912 Infiltration ..................... 19427 14653 Internal Gain .................... n/a 2614 Ducts ............................ 5714 5933 Sensible Load .................... 62854 65262 Latent Load ...................... n/a 19579 Minimum Total Load 62854 84840 (E) Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. AC SIZING Page 5 HVAC - Vct Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1566 sf Volume ........................... 16770 cf Description Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 6712 3642 Glazing Conduction ............... 10870 10584 Glazing Solar .................... n/a 6694 Infiltration ..................... 8855 6679 Internal Gain .................... n/a 1145 Ducts ............................ 2644 2874 Sensible Load .................... Latent Load ..................... Minimum Zone Load ZONE 'SLEEPING' W6I01 K n/a 29082 31618 9485 41104 Floor Area ....................... 1534 sf Volume ........................... 14585 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7293 4078 Glazing Conduction ............... 5775 5623 Glazing Solar .................... n/a 4689 Infiltration ..................... 7702 5809 Internal Gain .................... n/a 1131 Ducts ............................ 2077 2133 Sensible Load .................... 22846 23463 Latent Load ...................... n/a 7039 Minimum Zone Load 22846 30502 AC SIZING Page 6 HVAC yct Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Descrintion Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 1925 1875 Glazing Solar .................... n/a 2529 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 338 Ducts ............................ 993 926 Sensible Load .................... Latent Load ..................... Minimum Zone Load 10926 n/a 10926 10181 3054 13235 'AC SIZING Page 7 HVAC --iect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume .. ..... ............ Front Orientation.......... Sizing Location............ Latitude... ..... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3704 sf 36791 cf Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 180 deg (S) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 19142 10068 Glazing Conduction ............... 18570 18082 Glazing Solar .................... n/a 13887 Infiltration ..................... 19427 14653 Internal Gain .................... n/a 2614 Ducts ............................ 5714 5930 Sensible Load .................... Latent Load ...................... 62854 n/a 65234 19570 Minimum Total Load 62854 84804 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. TAC SIZING Page 8 HVAC sect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1566 sf Volume ........................... 16770 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6712 3642 Glazing Conduction ............... 10870 10584 Glazing Solar .................... n/a 5430 Infiltration ..................... 8855 6679 Internal Gain .................... n/a 1145 Ducts ............................ 2644 2748 Sensible Load .................... 29082 30228 Latent Load ...................... n/a 9068 Minimum Zone Load 29082 39296 ZONE 'SLEEPING' Floor Area ....................... 1534 sf Volume ........................... 14585 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7293 4078 Glazing Conduction ............... 5775 5623 Glazing Solar .................... n/a 7251 Infiltration ..................... 7702 5809 Internal Gain .................... n/a 1131 Ducts ............................ 2077 2389 Sensible Load .................... 22846 26281 Latent Load ...................... n/a 7884 Minimum Zone Load 22846 34165 'AC SIZING Page 9 HVAC --sect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Heating Description (Btuh) Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Zone Load 5137 1925 n/a 2870 n/a 993 10926 n/a Cooling (Btuh) 2348 1875 1206 2165 338 793 8726 2618 10926 11343 'AC SIZING Page 10 HVAC •nZect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House GENERAL INFORMATION Floor Area ................. Volume .. ..... ............ Front Orientation.......... Sizing Location............ Latitude... .. .. ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range. .. ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 3704 sf 36791 cf Front Facing PALM DESERT 33.7 degrees 32 F 70 F 112 F 75 F 34 F No No Yes 0.30 HEATING AND COOLING LOAD SUMMARY 270 deg (W) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 19142 10068 Glazing Conduction ............... 18570 18082 Glazing Solar .................... n/a 14047 Infiltration ..................... 19427 14653 Internal Gain .................... n/a 2614 Ducts ............................ 5714 5946 Sensible Load .................... Latent Load ..................... 1K 1610 n/a 65410 19623 Minimum Total Load 62854 85034 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. AC SIZING Page 11 HVAC . ect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'LIVING' Floor Area ....................... 1566 sf Volume ........................... 16770 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6712 3642 Glazing Conduction ............... 10870 10584 Glazing Solar .................... n/a 6694 Infiltration ..................... 8855 6679 Internal Gain .................... n/a 1145 Ducts ............................ 2644 2874 Sensible Load .................... 29082 31618 Latent Load ...................... n/a 9485 Minimum Zone Load 29082 41104 ZONE 'SLEEPING' Floor Area ....................... 1534 sf Volume ........................... 14585 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 7293 4078 Glazing Conduction ............... 5775 5623 Glazing Solar .................... n/a 4824 Infiltration ..................... 7702 5809 Internal Gain .................... n/a 1131 Ducts ............................ 2077 2147 Sensible Load .................... 22846 23612 Latent Load ...................... n/a 7083 Minimum Zone Load 22846 30695 7AC SIZING Page 12 HVAC 'niect Title.......... Heritage, Plan 3B, Guest3 Date........ 03/18/99 MICROPAS4 v4.50 File-HERIT3G3 Wth-CTZ15S92 Program-HVAC SIZING User#-MP1657 User-Haynal and Company, Inc. Run -Typical House ZONE 'GUEST' Floor Area ....................... 604 sf Volume ........................... 5436 cf Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 5137 2348 Glazing Conduction ............... 1925 1875 Glazing Solar .................... n/a 2529 Infiltration ..................... 2870 2165 Internal Gain .................... n/a 338 Ducts ............................ 993 926 Sensible Load .................... 10926 10181 Latent Load ...................... n/a 3054 Minimum Zone Load 10926 13235