HomeMy WebLinkAboutRFP ADA Accessibility Consulting Services - Addendum 2ADDENDUM NO. 2
TO REQUEST FOR PROPOSALS
Date: June 4, 2026
To: All prospective proposers
RFP: AMERICANS WITH DISABILITIES ACT ACCESSIBILITY COMPLIANCE
ASSESSMENT AND TRANSITION PLAN CONSULTING SERVICES
The following shall be considered as incorporated into the Request for Proposals for the above
referenced consulting services, published on May 18, 2026.
The following are the City's responses to all questions received as part of this RFP process:
Proposals — Consideration, Subcontracting, Timeline, Budget,
ADA Coordinator, CASP Certification
Question No. 1: Will the City consider proposals scoped only to the web and digital
accessibility components (Task 4, and the digital portions of Tasks 6, 7, and 8), or must
proposers respond to the full scope?
Question No. 2: Is the City seeking a single vendor with demonstrated capabilities across both
physical and IT accessibility domains?
Question No. 3: If separate areas of expertise are acceptable, would a proposal limited in
scope to IT / digital accessibility solutions be considered compliant and evaluated accordingly?
Answer: The City will consider limited scope proposals to only one or only a few of the
requested services from qualified firms.
Question No. 4: Section 111.6 indicates that subcontracting is not preferable but may be
considered when in the City's best interest. Given the multidisciplinary nature of this scope
(physical facilities, public right-of-way, programmatic, and digital accessibility), will proposals
that team a prime with specialist subcontractors be evaluated on equal footing with single -firm
proposals, provided the subcontracting structure is fully disclosed and justified?
Answer: Yes. When fully disclosed and properly justified, proposals that include
subcontractors will be evaluated on an equal basis with all other proposals.
Question No. 5: Is there a completion timeframe and budget in mind?
Question No. 6: Is there an estimated project budget or not -to -exceed amount?
Question No. 7: Is there an established budget or not -to -exceed amount for this project that
consultants should be aware of when developing their proposals?
Page 1 of 7
hiadiftei
Question No. 8: Project Budget and Implementation Planning Expectations — please clarify
whether the City has an anticipated project budget range, target implementation phases,
preferred prioritization methodology, or expectations regarding the level of detail required for
cost estimating and capital improvement planning within the ADA Transition Plan.
Question No. 9: Is there a target completion date or desired timeframe for delivery of the final
Transition Plan?
Answer: At this time, the City does not have a specific completion timeline or budget. These
will be established based on the compliance items identified in the City's self -assessment,
which will be conducted by the firm selected under this RFP, to bring the City into compliance
with current ADA regulations. The City's intent is for the selected firm to address as many items
as is feasible in the Transition Plan(s) before the April 26, 2028, compliance deadline.
Question No. 10: Does the City anticipate a lump sum or time -and -materials contract structure
for this engagement?
Answer: All proposals received will be considered. The manner in which a proposal is
submitted is at the discretion of each firm.
Question No. 11: Does the City currently have a designated ADA Coordinator? If so, will that
individual serve as the primary point of contact throughout the project?
Answer: Yes, the City has a designated ADA Coordinator. Several City staff members from
departments citywide will be primary points of contact throughout the project.
Question No. 12: Is CASP certification (Certified Access Specialist) required for this RFP?
Answer: GASP certification is not required for this RFP, as the federal ADA focuses on
compliance with ADA standards, and does not specify any particular credentials for someone
to perform accessibility evaluations; however, it is recommended.
Digital Accessibility
Question No. 13: Is the vendor expected to perform hands-on remediation of any web pages,
documents (PDFs, Word), or multimedia, or only to identify accessibility issues and provide
remediation recommendations and a roadmap as part of the Transition Plan?
Answer: The firm selected under this RFP is expected to identify accessibility barriers,
recommend appropriate remediation measures, prepare a digital accessibility Transition Plan,
and collaborate with City staff to develop a roadmap for achieving compliance.
Question No. 14: If remediation of assets is expected, can the City please specify which types
and approximate volumes?
Answer: The firm selected under this RFP is expected to identify this information as part of the
scope of work.
Page 2 of 7
athita
�,iI,ORNIA
Question No. 15: How many public -facing documents (PDFs, Word, etc.) are in scope, and
what is the approximate total page volume?
Answer: The firm selected under this RFP is expected to identify this information as part of the
scope of work.
Question No. 16: How many public -facing websites, subsites, web applications, portals, and
online forms/payment systems are in scope? Can the City provide the URLs or an inventory?
Question No. 17: Please identify the City's digital assets to be assessed, including the number
of websites/subsites, web applications, portals, online forms, payment systems, mobile apps,
PDFs/documents, and multimedia files.
Answer:
➢ Digital assets — The firm selected under this RFP is expected to identify this information
as part of the scope of work.
➢ Websites / subsites — City website (https://www.laquintaca.gov);
City tourism website (https://www.playinlaquinta.com)
➢ Web applications, portals, payment systems, mobile apps — Enclosed as Attachment 1
to this Addendum No. 2 is the City's Enterprise Systems Catalog for a list of public -
facing software and hosted services used by City departments that collect, store,
exchange, or analyze information about the public or City operations.
➢ Online form, PDFs / documents, and multimedia files — unknown; the firm selected under
this RFP is expected to identify this information as part of the scope of work.
Question No. 18: For the digital accessibility assessment, does the City anticipate: a
comprehensive review of all digital content and documents, statistically valid sampling,
department -based sampling, or prioritized/high-use content review?
Answer: The firm selected under this RFP is expected to conduct a comprehensive review of
all digital content and identify accessibility barriers, recommend appropriate remediation
measures, prepare a digital accessibility Transition Plan, and collaborate with City staff to
develop a roadmap for achieving compliance.
ADA Transition Plan
Question No. 19: Does the City have an existing ADA Transition Plan? Would this process be
an update to an existing assessment(s)?
Question No. 20: Is this the City's first time completing a self -evaluation and ADA Transition
Plan, or is this an update to an existing plan? If an existing plan is in place, will it be made
available to the selected consultant?
Page 3 of 7
Question No. 21: Beyond the written Transition Plan document, does the City anticipate
needing a platform or database solution to track identified deficiencies, prioritize corrective
actions, and monitor progress toward compliance over time?
Question No. 22: Is there a target completion date or desired timeframe for delivery of the final
Transition Plan?
Question No. 23: Please identify any existing ADA transition plans, self -evaluations, facility
inventories, GIS databases, curb ramp inventories, digital accessibility audits, remediation
reports, or related accessibility documentation that will be made available to the selected
consultant.
Answer: The City has completed a self -evaluation and ADA Transition Plan previously and is
seeking to update the existing plan, which will be made available to the firm selected under this
RFP. Enclosed as Attachment 4 to this Addendum No. 2 is an ADA Transition Plan Report as
of April 1, 2026.
At this time, the City does not have a specific completion timeline; it will be established based
on the compliance items identified in the City's self -assessment, which will be conducted by
the firm selected under this RFP to bring the City into compliance with current ADA regulations.
The City's intent is for the selected firm to address as many items as is feasible in the Transition
Plan(s) before the April 26, 2028, compliance deadline.
Facilities Accessibility
Question No. 24: Does the City know how many sidewalks, curb ramps and intersections it
operates?
Question No. 25: Please provide a count and listing (or map) of city -owned properties/facilities
included as part of the compliance evaluation.
Question No. 26: May we have the following information for the sites included in the
assessment: Facilities — square footage; Parks — amenities, acreage, trail information.
Question No. 27: May we have a list of facilities that are in scope including details of their use?
Question No. 28: Please provide a complete inventory of City facilities, parks, parking lots,
and other sites to be assessed, including names, addresses, approximate square footage, and
site types.
Question No. 29: How many facilities are anticipated to be included in the self -evaluation? If
available, could you provide the approximate square footage and location of each facility?
Question No. 30: Please provide a list of facilities that will need to be surveyed.
Question No. 31: Please provide a list of any parks that will need to be surveyed.
Page 4 of 7
Question No. 32: The RFP does not contain a list of leased and owned facilities. Can the City
provide a list of facilities, parks, parking lots, etc. to be included in the project to develop the
fee proposal?
Answer: Enclosed as Attachment 2 to this Addendum is a list of City facilities incorporated
into the scope of work under this RFP.
Answer: Enclosed as Attachment 3 to this Addendum is a list of City parks and recreation
facilities incorporated into the scope of work under this RFP.
Question No. 33: Please provide available public right-of-way inventory quantities, including
sidewalk miles, curb ramps, intersections, signalized crossings, pedestrian push buttons.
Question No. 34: Can the City provide an estimate of the total sidewalk miles and number of
curb ramps within its boundaries?
Question No. 35: Does the City know how many sidewalks, curb ramps and intersections it
operates?
Question No. 36: May we have the following information for the sites included in the
assessment: PROW — Number of signalized intersections / stop lights.
Question No. 37: Please provide quantities for the following:
a) A count and listing (or map) of the City -owned properties / facilities included as part of
the compliance evaluation
b) Miels of Sidewalk
c) A count of Crosswalks
d) Estimated number of curb ramps
e) Estimated count of signals / signalized intersections included in the project
f) Number of policies to be evaluated
Question No. 38: Can the City provide an estimate of the total sidewalk miles and number of
curb ramps within its boundaries?
Question No. 39: The RFP requests that the consultant assess the Public Rights -of -Way. In
order to ensure all bidders utilize the same metrics within the PROW for the fee proposal, can
the City provide the mileage of sidewalk, number of curb ramps, number of signalized
intersections and pedestrian push buttons, number of on -street accessible parking stalls, and
the number of transit stops required to be assessed as part of the assessment process?
Question No. 40: Please share how many miles of sidewalks will need to be surveyed.
Question No. 41: Please share how many intersections will need to be surveyed, including
curb ramps, pedestrian crossings, and pedestrian signals.
Question No. 42: Provide an estimate of how many on -street parking / parking lots will need
to be surveyed.
Page 5 of 7
Question No. 43: Please indicate whether transit stops and shelters will be a part of the PRoW
evaluation and, if so, how many.
Answer: The City owns and operates 121 miles of sidewalk.
Answer: The City owns and operates approximately 500 crosswalks, and 20 painted
crosswalks.
Answer: The City owns and operates approximately 400 to 415 pedestrian push buttons.
Answer: The City owns and operates 56 signalized intersections; the number of non -signaled
intersections are unknown
Answer: The current number of curb ramps is unknown; the firm selected under this RFP is
expected to identify this information as part of the scope of work.
Answer: Approximately 40-50 administrative policies citywide will need to be evaluated as part
of the scope of work under this RFP.
Answer: The City does not own or operates on -street accessing parking stalls.
Answer: The City does not own or operate any transit stops as they are owned and operated
by Sunline Transit Agency.
Answer: The City owns, operates, and will need to have assessed off-street accessible parking
stalls at the following locations:
✓ Cove Trailhead West ✓ Fire Station - Desert Club and 52
✓ Cove Trailhead East V Maintenance and Operations Yard
✓ Fire Station - Madison and Ave 54 ✓ La Quinta Library
✓ Bear Creek Trail - Eisenhower and ✓ Wellness Center
Tampico V Civic Center North Lot
✓ La Quinta Museum ✓ Civic Center South Lot
✓ La Quinta Community Park ✓ Point Happy Park
✓ Navarro Plaza V X-Park
✓ Montezuma Parking Lot V La Quinta Park
✓ Avenida La Fonda Parking ✓ Pioneer Park
✓ Calle Estado Parking V Sports Complex
✓ Fritz Burns Park
✓ YMCA - Moon River
Question No. 44: Does the City have any restrictions on use of small mobile inspection
platforms/motorized carts that can be driven on public sidewalks?
Answer: The City has no restrictions on the use of small mobile inspection platforms or
motorized carts for public sidewalks.
Page 6 of 7
hiadiftei
11 I I n I< N I A -
Question No. 45: Does the City currently utilize a GIS platform? If so, would geospatial data
such as facility locations, parcel boundaries, or existing infrastructure layers be available to the
consultant?
Question No. 46: Does the City require GIS deliverables? If yes, please identify the required
platform, file format, schema, coordinate system, and whether the City will provide existing GIS
layers.
Answer: Yes, the City does utilize a GIS platform. Yes, the City's GIS mapping and special
data management, and the files would be made available to the firm selected under this RFP.
The City's GIS requirements are as follows:
File Format:
• File Geodatabase (.gdb) — preferred as the primary deliverable format
• Shapefiles (.shp) are acceptable as a secondary/backup format but not preferred (field
length limits, no domain support, etc.)
Coordinate system is NAD 1983 StatePlane California Zone 6 (FIPS 0406), WKID 2230
• Feature types broken out logically (sidewalks, curb ramps, barriers, accessible parking,
etc.) as separate feature classes or at minimum a feature type attribute
• Condition/compliance fields with domain -coded values (not free text)
• A unique identifier field (AssetlD, etc)
• Photo attachment capability if necessary (photo IDs, etc)
Question No. 47: Please clarify whether the consultant's responsibilities are limited to
assessment, planning, and recommendations, or whether the City expects hands-on
remediation support for physical barrier corrections during the contract term.
Answer: The City does not expect hands-on remediation support for physical barrier
corrections.
In all other respects the original RFP shall remain in effect.
*******************************************************
Published June 4, 2026
(
Monika Radeva, City Clerk
City of La Quinta
End of Addendum No. 2
Page 7 of 7
City of La Quinta
Enterprise Systems Catalog
Pursuant to Senate Bill 272 (Gov. Code § 7922.700; Formerly Gov. Code § 6270.5)
ATTACHMENT 1
City of La Quinta Catalog Last Updated: January 26, 2026
In accordance with California Senate Bill 272 (2015), the City of La Quinta publishes this catalog of enterprise information systems. This catalog lists software and hosted services used by City departments that collect,
store, exchange, or analyze information about the public or City operations. Free or publicly available utilities (such as Microsoft Edge or Adobe Reader) are excluded.
Requirement/Aspect
Former Location (Pre-2023)
Current Location (Post -AB 473)
Enterprise Systems Catalog
Section 6270.5
Sections 7922.700-7922.725
Disclosure Rules
Section 6270.5
7922.710, 7922.715, 7922.720
Definitions & Exclusions
Section 6270.5
7922.700
Legal Reference
Section 6270.5
7922.700-7922.725
Effective Date 2016 (SB 272)
Jan 1, 2023 (AB 473)
IA IT
Creative Cloud
PDF editing and design software for City staff mi1Documents
Daily
Applied Geodetics, Inc.
IT
GIS Consulting Services
Maintains LQGIS database and TRAKit integration
Spatial / Infrastructure Data
Monthly
Monthly
AutoDesk MN"
BlueBeam Inc.
Design &
Development
Public Works /
Building
AutoCAD / Civil 3D
Studio Prime
Architectural design and plan review
Electronic plan review and markup integrated with Tyler Documents
As Needed
Daily
As Needed
Daily
ICablecast (Triton Technologies) City Clerk
Carahsoft Technology Corp
IT
.iteflect Server +
Zoom Phone Services
Broadcast and Record public meetings for public access (Video Recordings / Access Logs
Citywide telecommunications and conferencing platform User Accounts, Call Metadata, Recordings
■I Per Meeting
Continuous
Continuous
As Needed
DataTicket
Public Safety/Code
Compliance
Citation Processing
Track and manage parking and administrative citations Citation information, case data, including violation
through enforcement, adjudication, and collection details, vehicle and respondent information, hearing
processes. outcomes, payments, and collection activity.
IF'
Continuous
Continuous
Deckard Technologies, Inc.
City Clerk
RentalScape
Short -Term Vacation Rental Program Compliance
Monitoring
Residential business rental activities
Continuous
Continuous
DocuSign
eSignature Platform
Digital signing of City forms and contracts
1
Documents / Signatures
As Needed
ESRI
IT / Design &
Development
ArcGIS Online / ArcGIS Pro
GIS mapping and spatial data management
Geographic / Spatial Data
Weekly /
Continuous Monthly
GoGov IIMIM
Code Compliance & GoEnForce
Facilities GoRequest
Code Enforcement Case Management & Citizen Requests Electronic code actions tracking
Daily
Daily
Governmentiobs.com, Inc. DBA
NEOGOV
Human Resources
NeoGov
Online Application System
Recruitment System / Job Applications
As Needed
As Needed
Govinvest, Inc.
r
Finance
•IGiovinvest
Pension & Health Benefits Management & Actuarial
Reporting
'Pension & other post -employment benefits (OPEB) I Annually
Annually
GovOS
City Clerk
MUNIRevs
LodgingRevs
Short -Term Vacation Rental Program Management, TOT
Collection, Compliance Monitoring
Electronic permit applications management & tracking;
online payments; compliance monitoring
Continuous
Continuous
Granicus IT
Vision City Website Content Management
City website public information & documents
Daily Daily
JCG Technologies, Inc City Clerk
Liberty Meeting Recorder & Player Audio recordings of public meetings
Audio Recordings
As Needed As Needed
LaserFiche
J
City Clerk
Digital Archive Repository — On Prem Electronic document management system
1
Documents / Records
Continuous
Continuous
Microsoft (via Riverside County) IT
Microsoft 365 (Visual Edge IT
administered)
Citywide email, file sharing, and collaboration
Email & Documents
Continuous Daily
PastPerfect
Museum
Past Perfect 5.0
Collection Management
Museum / Local history archives
MIMI Daily Dai
Ring (Amazon Services)
IT
Ring Protect / Ring for Business
Server room video monitoring for security and access
control
Video Recordings / Access Logs
Continuous
Continuous
Tyler Technologies
Design &
Development
Permitting & Licensing Management
Electronic project & permit applications management &
tracking; online applications & payments Continuous
Continuous
Tyler Technologies
Finance
Incode / Munis ERP
Financial and HR Management system
Finance, Accounting, Personnel Management
Continuous
Continuous
Vermont Systems, Inc.
Community Services RecTrak
Recreation Class & Membership Management
Registration for classes, programs, events & rentals
ATTACHMENT 2
City of La Quinta Facilities
Facility Name
Location
Sq. Ft.
1
Boys & Girls Club
49995 Park Avenue
12,000
2
City Hall/Civic Center
78495 Calle Tampico
54,553
3
Colonel Mitchell Paige Restroom Building
43495 Palm Royale Dr.
125
4
Cove Restroom (Cove to Lake trailhead)
Avenida Bermudas & CalleTecate
50
5
Fire Station 32
78111 Avenue 52
7,500
6
Fire Station 32 (OLD)
78-136 Francis Hack Lane
5,000
7
Fire Station 70
54001 Madison Street
5,700
8
Fire Station 93
44555 Adams Street
7,700
9
Fritz Burns Pool
51885 Avenida Bermudas
1,900
10
La Quinta Library
78275 Calle Tampico
20,500
11
La Quinta Museum
77885 Avenida Montezuma
7,700
12
La Quinta Park (Restroom/Snack)
79120 Westward Ho
2,600
13
La Quinta Realty Building
51001 Eisenhower
1,000
14
La Quinta YMCA
49955 Moon River Drive
10,000
15
Old Lumber Yard
77895 Avenida Montezuma
2,570
16
Public Works Building
78106 Frances Hack Lane
2,200
17
Silver Rock Event Building
51900 Silver Rock Way
4,300
18
Silver Rock Event Restrooms Building
51900 Silver Rock Way
500
19
SilverRock Clubhouse
79179 Ahmanson Lane
4,800
20
SilverRock Maintenance Yard
79600 Avenue 54
10,000
21
Sports Complex
78900 Avenue 50
880
22
Wellness/Senior Center
78450 Avenida La Fonda
22,000
23
X-Park Building
46170 Dune Palms Road
1,500
ATTACHMENT 3
Park
Address
Acreage
Amenities
1 Adams Park
3.5
1994
2 Bear Creek Trail
2.6 miles
1991
3 Civic Center Campus
17.5
2002
*4 Colonel Mitchell Page
43495 Palm Royale Drive
Restr000ms
5 Cove Oasis Trailhead
12
2001
6 Desert Pride Park
1
2000
7 Eisenhower park
0.5
2002
*8 Fritz Burns Park
12
1994 Pool - Restrooms - Snack Bar
Fred Wolff Bear Creek
9 Nature Preserve
28
2006
* 10 La Quinta Park
18
2002 Restr000ms - Snack bar
11 Monticello Park
4
2003
12 Pioneer Park
(inc.Well Site)
3.2
2008
13 Saguaro Park
0.75
2002
14 Seasons Park
5
2000
15 Velasco Park
0.25
2002
16 Sports Complex
17 SRR Event Park
18 X-Park
LQ Middle School
51930 SilverRock Way
Black Hawk Way/Dune Palms
17
11.5
3.5
2021 Restrooms/Alongi Bldg/stage
CLQ Facilities
Address
Acreage
Age Phone #
*1 LQ Library
78275 Calle Tampico
20,000 sf
2005 (760)564-4767
*2 LQ Historical Museum
77885 Avenida Montezuma
924sf(8,000addition)
2008 (760)777-7170
*3 Wellness Center
78450 Avenida La Fonda
10,000 sf
1994
*4 Silverrock Resort
79179 Ahmanson Ln
525
2005 (760)777-8884
5 Old LumberYard
Montezuma
1 Other Facilities
Address
Acreage
Phone #
1 Boys & Girls Club
49995 Park Ave
12,000 sf
2 LQ Community Park
Blackhawk Way
6.5
5 YMCA
49955 Moon River
10,000 sf
(760)771-1811
i A School Facilities
6
Address
Acreage
s Phone #
6 Sports Complex
78900 Avenue 50
16.75
(760)564-2268
Boys & Girls Club
Parking
ATTACHMENT 4
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30595
Parking Off Of Park Avenue
There is no device at the head of the general parking spaces to
prevent vehicles from encroaching into walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
)stall a wheel stop at the head of the general parking spaces.
tiority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$240
$0.00
Record Number 30608
Parking Off Of Park Avenue
Parking Lot Warning Sign
The point of contact and telephone number for reclaiming towed
vehicles have been left blank.
Finding Sign not Filled
CA 11B-502.8.2
II in the blank spaces with the point of contact and telephone
umber for reclaiming towed vehicles.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 30596
Parking Off Of Park Avenue
Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 98.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
Re -stripe the accessible parking space.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 1 of 853
Record Number 30597
Parking Off Of Park Avenue
Left Accessible Space
The slope of the accessible parking space is not compliant.
Finding 9.10 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
riority Five
.esolution Not Set
'rogress Not_Started
assignment Not Set
$3,800
$0.00
Record Number 30598
Parking Off Of Park Avenue
Left Accessible Space
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
istall a wheel stop at the head of the accessible parking space.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 30599
Parking Off Of Park Avenue
Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 2 of 853
Record Number 30601
Parking Off Of Park Avenue
Left Accessible Space
There is no additional signage marked "van accessible" at the van
accessible parking space.
Finding None Found
ADA 4.6.4
an accessible parking spaces shall provide additional signage
'at states "van accessible" .
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 30602
Parking Off Of Park Avenue
Left Accessible Space
The slope of the access aisle is not compliant.
Finding 5.20 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
°epave the access aisle to provide a compliant surface slope.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$3,800
$0.00
Record Number 30600
Parking Off Of Park Avenue
Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 37.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
provide compliant surface identification at the accessible parking
Dace.
riority Five
esolution Not Set
'rogress Not_Started
_.ssignment Not Set
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 3 of 853
Record Number 30603
Parking Off Of Park Avenue
Right Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 104.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Five
esolution Not Set
'regress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 30604
Parking Off Of Park Avenue
Right Accessible Space
The slope of the accessible parking space is not compliant.
Finding 7.20 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
Repave the accessible space to provide a compliant slope.
riority Five
esolution Not Set
'regress Not_Started
Assignment Not Set
$3,800
$0.00
Record Number 30605
Parking Off Of Park Avenue
Right Accessible Space
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
install a wheel stop at the head of the accessible parking space.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 4 of 853
Record Number 30606
Parking Off Of Park Avenue
Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$300
$0.00
Record Number 30607
Parking Off Of Park Avenue
Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 37.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$220
$0.00
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30631
Curb Ramp From The Parking Lot North East Of The Main
Entrance
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 5 of 853
Record Number 30632
Curb Ramp From The Parking Lot North East Of The Main
Entrance
The running slope is greater than allowed.
Finding 8.80 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
rovide a compliant curb ramp.
riority Five
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$1,300
$0.00
Record Number 30633
Curb Ramp From The Parking Lot North East Of The Main
Entrance
The slope of the curb ramp left side flare is greater than allowed.
Finding 15.20 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
rovide curb ramp side flares with a compliant slope.
riority Five
.esolution Not Set
rogress Not_Started
,assignment Not Set
$1,300
$0.00
Record Number 30634
Curb Ramp From The Parking Lot North East Of The Main
Entrance
Bottom Landing
The slope at the bottom landing is greater than allowed.
Finding 6.20 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.3.2
rovide a compliant bottom landing that does not exceed the
iaximum slope requirements.
Priority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$240
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 6 of 853
Record Number 30719
Curb Ramp At The Head Of The Access Aisle
The curb ramp projects into vehicular traffic lanes, parking spaces,
or parking access aisles.
Finding Projects
ADA 4.7.6, CA 11B-406.5
rovide a compliant curb ramp.
riority Five
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$1,400
$0.00
Record Number 30720
Curb Ramp At The Head Of The Access Aisle
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Five
esolution Not Set
rogress Not_Started
,assignment Not Set
$248
$0.00
Record Number 30721
Curb Ramp At The Head Of The Access Aisle
Top Landing
The curb ramp does not provide a grooved border along the top
and sides of the ramp at the level of the sidewalk.
Finding None Found
CA 11B-406.5.11
rovide a compliant grooved border along the top and sides of
le curb ramp at the level surface of the sidewalk.
Priority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 7 of 853
Record Number 30783
Curb Ramp From Crosswalk Next To YMCA Facility
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Five
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$248
$0.00
Record Number 30784
Curb Ramp From Crosswalk Next To YMCA Facility
The slope of the curb ramp left side flare is greater than allowed.
Finding 26.30 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
rovide curb ramp side flares with a compliant slope.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,300
$0.00
Record Number 30785
Curb Ramp From Crosswalk Next To YMCA Facility
Bottom Landing
The slope at the bottom landing is greater than allowed.
Finding 7.90 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.3.2
rovide a compliant bottom landing that does not exceed the
iaximum slope requirements.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$240
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 8 of 853
Record Number 30786
atch the transition area at the bottom of the curb ramp so that
le transition is flush and free of abrupt changes.
$255
$0.00
Curb Ramp From Crosswalk Next To YMCA Facility
Bottom Landing
The transition from the bottom of the curb ramp to the walk,
gutter, or street is abrupt.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.5.2, ADA 406.5.8
riority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30775
Ramp To City Owned Room West Entrance
Run 1 Bottom Landing
The length of the bottom landing does not meet the required
minimum length.
Finding 55.50 inches
Code At least 72.00 inches
ADA 4.8.4, CA 11B-405.7.3.1
odify or replace the bottom landing to provide the required
iinimum length and width.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,87,
$0.00
Record Number 30778
Ramp To City Owned Room West Entrance
Run 1 Intermediate Landing
The ramp changes direction. The length of landing is less than the
required minimum length.
Finding 55.00 inches
Code At least 72.00 inches
ADA 4.8.4, CA 11B-405.7.4
Modify or replace landing to provide the required minimum
length and width.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,872
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 9 of 853
Record Number 30776
Ramp To City Owned Room West Entrance
Run 1 Intermediate Landing
The ramp changes direction. The width of the landing does not
meet the minimum required width.
Finding 56.00 inches
Code At least 60.00 inches
ADA 4.8.4
odify or replace the landing to provide the minimum required
ngth and width.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,872
$0.00
Record Number 30777
Ramp To City Owned Room West Entrance
Run 1 Intermediate Landing
The ramp changes direction at this landing. The length of the
landing is less than the required minimum length.
Finding 55.00 inches
Code At least 60.00 inches
ADA 4.8.4
"lodify or replace the landing to meet the minimum required
idth and length.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,600
$0.00
Record Number 30779
Ramp To City Owned Room West Entrance
Run 1 Left Handrail
The handrail extension is not parallel to the floor or ground
surface.
Finding Not Parallel
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
Provide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
ie bottom of the ramp and return smoothly to the post or wall.
riority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 10 of 853
Record Number 30780
Ramp To City Owned Room West Entrance
Run 2 Right Handrail
The handrail extension is not parallel to the floor or ground
surface.
Finding Not Parallel
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,400
$0.00
Record Number 30781
Ramp To City Owned Room West Entrance
Run 2 Left Handrail
The handrail extension is not parallel to the floor or ground
surface.
Finding Not Parallel
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
$2,400
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30695
Stairs To Community Room Entrance
Run 1
The striping on each tread of the stairway is not at a compliant
width.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
rovide compliant striping on each tread of the stairway.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$460
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 11 of 853
Record Number 30694
Stairs To Community Room Entrance
Run 1
There is no intermediate handrail available; the width of the
stairway requires that a middle handrail is installed.
Finding None Found
rovide an intermediate handrail spaced equally in the middle of
le stair run.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,528
$0.00
Record Number 30696
Stairs To Community Room Entrance
Run 1 Left Handrail
The gripping surface of the handrail is interrupted.
Finding Interrupted
ADA 4.9.4(4)
Demount the handrail so is not interrupted.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,840
$0.00
Record Number 30697
Stairs To Community Room Entrance
Run 1 Right Handrail
The gripping surface of the handrail is interrupted.
Finding Interrupted
ADA 4.9.4(4)
Demount the handrail so is not interrupted.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$1,840
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 12 of 853
Record Number 30611
Exterior Entrance To Kitchen
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 22.00 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance for the door.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$2,921
$0.00
Record Number 30612
Exterior Entrance To Kitchen
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 39.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
Provide the recommended clear floor space on the pull side of
'ie door.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$2,921
$0.00
Record Number 30609
Exterior Entrance To Kitchen
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 13 of 853
Record Number 30610
Exterior Entrance To Kitchen
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 30614
Main Entrance Next To Reception
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Record Number 30613
Main Entrance Next To Reception
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 14 of 853
Record Number 30615
Kitchen
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30617
Exterior Entrance To Game Room
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Record Number 30618
Exterior Entrance To Game Room
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 15 of 853
Record Number 30621
Right Door To Exercise Room
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30629
Learning Center
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30630
Door Between Staff Office & Game Room
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 16 of 853
Record Number 30636
Womens Restroom Next To Community Room
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30650
Health Center
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30658
Left Door To Exercise Room
Push / Pull
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 17 of 853
Record Number 30659
Entrance Next To Computer Room
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$400
$0.00
Record Number 30660
Entrance Next To Computer Room
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"lodify or replace the threshold to provide the recommended
eight.
tiority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
$436
$0.00
Record Number 30662
Door To Teen Room From Gymnasium
Push / Pull
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
tiority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 18 of 853
Record Number 30688
Exterior Entrance To Arts & Crafts
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
$400
$0.00
Record Number 30687
Exterior Entrance To Arts & Crafts
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
esolution Not Set
rogress Not_Started
Assignment Not Set
$25
$0.00
Record Number 30690
Door Between Gymnasium & Girls Locker Room
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 49.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
provide the recommended clear floor space on the pull side of
le door.
riority Six
esolution Not Set
rogress Not_Started
_.ssignment Not Set
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 19 of 853
Record Number 30689
Door Between Gymnasium & Girls Locker Room
Push / Pull
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30691
Door Between Gymnasium & Boys Locker Room
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30700
Exterior Door Next To Exercise Room
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 20 of 853
Record Number 30699
Exterior Door Next To Exercise Room
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30701
Exterior Door Next To Exercise Room
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 30708
South Exterior Door To Gymnasium
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 21 of 853
Record Number 30707
South Exterior Door To Gymnasium
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30712
Mens Restroom Next To Community Room
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 30715
North Exterior Door To Gymnasium
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 22 of 853
Record Number 30716
North Exterior Door To Gymnasium
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$50
$0.00
Record Number 30717
North Exterior Door To Gymnasium
The height of the threshold at the entrance door is greater than
allowed for a vertical rise.
Finding 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$257
$0.00
Record Number 30718
Door Between Game Room & Boys Locker Room
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 23 of 853
Record Number 30722
Door Between Reception & Game Room
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 9.50 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,000
$0.00
Record Number 30723
Door Between Computer Room & Small Computer Room
There is less than the required clearance between the two doors in
a series.
Finding 22.25 inches
Code At least 48.00 inches
ADA 4.13.7
Remove the inner door in a series to provide an accessible
ntrance.
riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$48
$0.00
Record Number 30733
Door To Offices From Main Lobby
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
requirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 24 of 853
Record Number 30735
Exterior Entrance To Community Room Off Park Avenue
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$400
$0.00
Record Number 30764
Board Room
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
esolution Not Set
rogress Not_Started
Assignment Not Set
$25
$0.00
Record Number 30789
Gate To Exterior Entrance To Kitchen
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 28.00 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
'rovide the recommended clear floor space on the push side of
le door.
riority Seven
esolution Not Set
'rogress Not_Started
_.ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 25 of 853
Record Number 30788
Gate To Exterior Entrance To Kitchen
The height of the threshold at the entrance door is greater than
allowed for a vertical rise.
Finding 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$257
$0.00
Record Number 30787
Gate To Exterior Entrance To Kitchen
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Record Number 30808
Door To Teen Room Next To Exercise Room
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$25
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 26 of 853
Record Number 30762
Kitchen Window
The height of the counter or desk does not comply with height
requirements.
Finding 41.62 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Six
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$3,500
$0.00
Record Number 30763
Kitchen Window
The counter is a protruding object.
Finding See Above
ADA 4.32.4, ADA 7.2
Hdjust the counter so that it is no longer a protruding object.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$450
$0.00
Record Number 30792
Reception Window Next To Game Room
The height of the counter or desk does not comply with height
requirements.
Finding 40.00 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 27 of 853
Record Number 30793
Reception Window Next To Game Room
The counter is a protruding object.
Finding See Above
ADA 4.32.4, ADA 7.2
djust the counter so that it is no longer a protruding object.
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$450
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30571
Path Of Travel From The Public Right Of Way Off Park Avenue
Next To NE Entrance
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 30551
Arts & Crafts
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
Tnstall compliant room identification signage.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 28 of 853
Record Number 30572
Door Between Staff Office & Game Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30573
Board Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30616
Door To Teen Room Next To Exercise Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 29 of 853
Record Number 30619
Exterior Entrance To Game Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30622
Exterior Door Next To Exercise Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30635
Community Room
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
install accessible room signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 30 of 853
Record Number 30651
Health Center
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30652
Computer Room
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30653
Door Between Computer Room & Small Computer Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 31 of 853
Record Number 30657
Left Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30661
Gate To Exterior Entrance To Kitchen
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30669
Hallway Door To Staff Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
priority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 32 of 853
Record Number 30686
Learning Center
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30692
Door To Offices From Main Lobby
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30693
Door Between Board Room And Offices
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 33 of 853
Record Number 30698
Right Door To Exercise Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30714
Right Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30734
Exterior Entrance To Kitchen
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 34 of 853
Record Number 30736
Reception Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30737
Exterior Entrance To Community Room Off Park Avenue
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30738
Door Between Learning Center & Small Computer Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 35 of 853
Record Number 30759
North Exterior Door To Gymnasium
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30760
Entrance Next To Computer Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30761
South Exterior Door To Gymnasium
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 36 of 853
Record Number 30765
Left Door To Exercise Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30774
Door To Teen Room From Gymnasium
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30782
Kitchen
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 37 of 853
Record Number 30791
Exterior Entrance To Arts & Crafts
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30795
Gymnasium
The accessible element/identification signage attached to the wall
does not include Braille characters.
Finding None Found
ADA 4.30.4, CA 11B-703.3
(stall accessible signage to include Grade 2 Braille characters.
riority Three
.esolution Not Set
'rogress Not_Started
,assignment Not Set
$50
$0.00
Record Number 30796
Gymnasium
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 67.75 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 38 of 853
Record Number 30794
Gymnasium
Braille is not located below the raised letters.
Finding None Found
ADA 4.4.2, CA 11B-703.3.2
ake sure that braille is located below the raised letters.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30797
Main Entrance Next To Reception
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30809
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 39 of 853
Record Number 30812
City Owned Room West Entrance
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30557
Girls Locker Room Restroom
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
' ower the mirror so the bottom edge of the reflective surface is
3 higher than recommended above the finished floor.
riority Four
esolution Not Set
rogress Not_Started
..ssignment Not Set
$300
$0.00
Record Number 30558
Girls Locker Room Restroom
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 60.25 inches
Code 60.00 inches
CA 11B-703.7.2.6
nest gender use signage on the center of the door at the
quired height.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 40 of 853
Record Number 30560
Girls Locker Room Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$158
$0.00
Record Number 30559
Girls Locker Room Restroom
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 30556
Girls Locker Room Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 41 of 853
Record Number 30553
Girls Locker Room Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.25 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 118-606.2
aise or replace the lavatory to provide the minimum required
iron height.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30554
Girls Locker Room Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,286
$0.00
Record Number 30555
Girls Locker Room Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 42 of 853
Record Number 30561
Girls Locker Room Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$158
$0.00
Record Number 30552
Girls Locker Room Restroom
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Six
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 30566
Boys Locker Room Restroom
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
Lower the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 43 of 853
Record Number 30562
Boys Locker Room Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.75 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
iron height.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30563
Boys Locker Room Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.50 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,286
$0.00
Record Number 30564
Boys Locker Room Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 44 of 853
Record Number 30565
Boys Locker Room Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 30569
Boys Locker Room Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30567
Boys Locker Room Restroom
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
. equired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 45 of 853
Record Number 30568
Boys Locker Room Restroom
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
3st gender use signage on the center of the door at the
?quired height.
tiority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 30570
Boys Locker Room Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
tiority Three
.esolution Not Set
'regress Not_Started
,assignment Not Set
$158
$0.00
Record Number 30574
Mens Restroom Next To Community Room
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Six
.esolution Not Set
'regress Not_Started
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 46 of 853
Record Number 30575
Mens Restroom Next To Community Room
The entrance door swings into the turning space within the
restroom.
Finding 44.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$8,200
$0.00
Record Number 30582
Mens Restroom Next To Community Room
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
I ower the mirror so the bottom edge of the reflective surface is
i to higher than recommended above the finished floor.
riority Seven
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
$300
$0.00
Record Number 30583
Mens Restroom Next To Community Room
The top of the mirror is not at the compliant height.
Finding 73.25 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 47 of 853
Record Number 30578
Mens Restroom Next To Community Room
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 27.75 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 118-606.2
aise or replace the lavatory to provide the minimum required
iron height.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30579
Mens Restroom Next To Community Room
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.75 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,286
$0.00
Record Number 30580
Mens Restroom Next To Community Room
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 48 of 853
Record Number 30581
Mens Restroom Next To Community Room
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 30585
Mens Restroom Next To Community Room
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 30584
Mens Restroom Next To Community Room
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.75 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 49 of 853
Record Number 30576
Mens Restroom Next To Community Room
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 30577
Mens Restroom Next To Community Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 30637
Womens Restroom Next To Community Room
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
Modify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 50 of 853
Record Number 30638
Womens Restroom Next To Community Room
The entrance door swings into the turning space within the
restroom.
Finding 38.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$8,200
$0.00
Record Number 30644
Womens Restroom Next To Community Room
The top of the mirror is not at the compliant height.
Finding 73.25 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 30645
Womens Restroom Next To Community Room
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.75 inches
Code 60.00 inches
CA 11B-703.7.2.6
Post gender use signage on the center of the door at the
required height.
riority Seven
esolution Not Set
'rogress Not_Started
ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 51 of 853
Record Number 30641
Womens Restroom Next To Community Room
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,286
$0.00
Record Number 30642
Womens Restroom Next To Community Room
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 16.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
°eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
rogress Not_Started
assignment Not Set
$2,500
$0.00
Record Number 30643
Womens Restroom Next To Community Room
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 52 of 853
Record Number 30646
Womens Restroom Next To Community Room
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$158
$0.00
Record Number 30639
Womens Restroom Next To Community Room
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 30640
Womens Restroom Next To Community Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
_assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 53 of 853
Record Number 30667
Mens Restroom Next To Community Room
The distance from the side wall to the rear grab bar is greater
than allowed.
Finding 7.00 inches
Code Up to 6.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2
emount the rear grab bar at a compliant location.
tiority Four
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$78
$0.00
Record Number 30665
Mens Restroom Next To Community Room
The distance from the back wall to the front of the grab bar is less
than required.
Finding 48.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 30666
Mens Restroom Next To Community Room
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 19.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 54 of 853
Record Number 30668
Mens Restroom Next To Community Room
The toilet paper dispenser is not mounted at the required height.
Finding 15.25 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Record Number 30663
Mens Restroom Next To Community Room
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30671
Boys Locker Room Restroom
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 44.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 55 of 853
Record Number 30670
Boys Locker Room Restroom
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
tiority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Record Number 30683
Boys Locker Room Restroom
The coat hook is not mounted at the correct height.
Finding 61.50 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
Mount the coat hook at the recommended height.
tiority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 30680
Boys Locker Room Restroom
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Provide an accessible handle mounted on the door of the
)mpartment near the latch.
tiority Three
esolution Not Set
rogress Not_Started
.-ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 56 of 853
Record Number 30681
Boys Locker Room Restroom
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
priority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$269
$0.00
Record Number 30682
Boys Locker Room Restroom
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$129
$0.00
Record Number 30678
Boys Locker Room Restroom
The height of the side grab bar is not at the correct height.
Finding 34.00 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 57 of 853
Record Number 30679
Boys Locker Room Restroom
The grab bar on the rear wall is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
emount the rear grab bar in the compartment designated to
a accessible so the height of the gripping surface is at the
)rrect height.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$231
$0.00
Record Number 30676
Boys Locker Room Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.50 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 30677
Boys Locker Room Restroom
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 22.50 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 58 of 853
Record Number 30672
Boys Locker Room Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.37 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30674
Boys Locker Room Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30675
Boys Locker Room Restroom
There is less than the required minimum space in front of the
toilet.
Finding 45.75 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
tiority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 59 of 853
Record Number 30684
Boys Locker Room Restroom
The toilet paper dispenser is not mounted at the required height.
Finding 16.50 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Record Number 30702
Unisex Staff Restroom
There are no grab bars.
Finding None Found
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5
(stall the required grab bars in the toilet compartment.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 30705
Unisex Staff Restroom
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 14.00 inches
Code Up to 12.00 inches
rovide feminine products disposal at the required distance
om front of the toilet.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 60 of 853
Record Number 30704
Unisex Staff Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 38.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30745
Unisex Staff Restroom
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,800
$0.00
Record Number 30744
Unisex Staff Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
Install a compliant privacy lock with occupancy indicator to the
door.
riority Seven
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
$804
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 61 of 853
Record Number 30746
Unisex Staff Restroom
The entrance door swings into the turning space within the
restroom.
Finding 34.75 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$8,200
$0.00
Record Number 30756
Unisex Staff Restroom
The top of the mirror is not at the compliant height.
Finding 72.00 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 30753
Unisex Staff Restroom
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 26.00 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
Relocate the lavatory to provide clear floor space.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,261
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 62 of 853
Record Number 30754
Unisex Staff Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 30755
Unisex Staff Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$149
$0.00
Record Number 30749
Unisex Staff Restroom
Lavatory
The lavatory is in an enclosed cabinet, thereby preventing an
accessible forward approach.
Finding Not Accessible
ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306
Remove or modify the lavatory cabinet and provide a compliant
lavatory.
riority Seven
.esolution Not Set
rogress Not_Started
.ssignment Not Set
$420
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 63 of 853
Record Number 30750
Unisex Staff Restroom
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.62 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$1,286
$0.00
Record Number 30751
Unisex Staff Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 25.62 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$1,286
$0.00
Record Number 30752
Unisex Staff Restroom
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 14.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 64 of 853
Record Number 30758
Unisex Staff Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$158
$0.00
Record Number 30757
Unisex Staff Restroom
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 30747
Unisex Staff Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 52.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
_assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 65 of 853
Record Number 30748
Unisex Staff Restroom
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 30767
Womens Restroom Next To Community Room
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 47.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Record Number 30766
Womens Restroom Next To Community Room
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 66 of 853
Record Number 30772
Womens Restroom Next To Community Room
The distance from the side wall to the rear grab bar is greater
than allowed.
Finding 7.00 inches
Code Up to 6.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2
emount the rear grab bar at a compliant location.
tiority Four
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$78
$0.00
Record Number 30770
Womens Restroom Next To Community Room
The distance from the back wall to the front of the grab bar is less
than required.
Finding 48.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 30771
Womens Restroom Next To Community Room
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 19.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 67 of 853
Record Number 30773
Womens Restroom Next To Community Room
The toilet paper dispenser is not mounted at the required height.
Finding 15.25 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Record Number 30768
Womens Restroom Next To Community Room
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30806
Girls Locker Room Restroom
The coat hook is not mounted at the correct height.
Finding 61.75 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 68 of 853
Record Number 30803
Girls Locker Room Restroom
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
priority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 30804
Girls Locker Room Restroom
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$269
$0.00
Record Number 30805
Girls Locker Room Restroom
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Adjust the inside handle so that it is located near the latch.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$129
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 69 of 853
Record Number 30801
Girls Locker Room Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 48.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 30802
Girls Locker Room Restroom
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 20.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 30807
Girls Locker Room Restroom
The toilet paper dispenser is not mounted at the required height.
Finding 17.50 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser in the compartment to the
required height.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 70 of 853
Record Number 30798
Girls Locker Room Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 30800
Girls Locker Room Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30655
Drinking Fountain Next To The Main Entrance
There is less than the required minimum knee clearance height
Finding 26.75 inches
Code At least 27.00 inches
ADA 4.15.5, CA 11B-602.2, CA 11B-306
rovide a fountain with the required knee and toe clearances.
riority Six
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 71 of 853
Record Number 30656
Drinking Fountain Next To The Main Entrance
The drinking fountain is not set entirely in an alcove.
Finding None Found
CA 11B-602.9
rovide compliant wing walls or barrier at the drinking fountain.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$640
$0.00
Record Number 30654
Drinking Fountain Next To The Main Entrance
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
riority Six
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,500
$0.00
Record Number 30592
Drinking Fountain In Gymnasium
The height of the water stream is less than required.
Finding 2.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
Adjust the flow of the water stream to a compliant height.
°riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 72 of 853
Record Number 30593
Drinking Fountain In Gymnasium
There is not enough clear floor space width for a front approach to
the drinking fountain.
Finding 32.50 inches
Code At least 36.00 inches
ADA 4.2.4.2
rovide compliant clear floor space at the drinking fountain.
riority Seven
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$108
$0.00
Record Number 30594
Drinking Fountain In Gymnasium
There is not enough clear floor space for a parallel approach in an
alcove.
Finding 55.00 inches
Code At least 60.00 inches
ADA 4.2.4.2, CA 11B-602.2, CA 11B-305.7.2
rovide the required clear floor space or reduce the depth of
le alcove.
tiority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$108
$0.00
Record Number 30591
Drinking Fountain In Gymnasium
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
tiority Six
esolution Not Set
'rogress Not_Started
.,ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 73 of 853
Record Number 30620
Drinking Fountain In Game Room
eplace the drinking fountain with a compliant High/Low
)untain.
$2,500
$0.00
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
riority Six
.esolution Not Set
rogress Not_Started
.ssignment Not Set
Assembly Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30713
Gymnasium
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 4.00 seats
CA 11B-221.2, CA 11B-802.1
provide a compliant amount of accessible seats.
riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$600
$0.00
Locker Rooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30706
Boys Locker Room
There are no accessible benches in the locker room.
Finding None Found
ADA 4.35.4, ADA 4.37
)stall compliant benches in the locker room.
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 74 of 853
Record Number 30790
Girls Locker Room
There are no accessible benches in the locker room.
Finding None Found
ADA 4.35.4, ADA 4.37
(stall compliant benches in the locker room.
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30811
Visual Alarms
There are visual warning devices provided throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
Since visual warning devices are provided in all areas of the
icility, no additional action is required.
Priority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$0.00
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30724
Board Room
The table knee clearance does not meet required standards.
Finding 26.75 inches
Code At least 27.00 inches
CA 11B-902.2, CA 11B-305, CA 11B-306
rovide compliant tables.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 75 of 853
Record Number 30725
Board Room
The table knee width does not meet required standards.
Finding 22.00 inches
Code At least 30.00 inches
ADA 4.27
rovide compliant tables.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
$2,174
$0.00
Record Number 30726
Board Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Two
.esolution Not Set
rogress Not_Started
,assignment Not Set
$158
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30709
Kitchen
Sink counter height is not compliant.
Finding 35.75 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
"rovide compliant sink.
riority Seven
.esolution Not Set
rogress Not_Started
.ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 76 of 853
Record Number 30710
Kitchen
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
aainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$149
$0.00
Record Number 30711
Kitchen
There is not enough clear floor space at the sink.
Finding 47.00 inches
Code At least 48.00 inches
CA 11B-606.2
rovide enough clear floor space at the location.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$900
$0.00
Record Number 30727
Arts & Crafts
Sink counter height is not compliant.
Finding 36.00 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
°riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 77 of 853
Record Number 30728
Arts & Crafts
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$420
$0.00
Record Number 30729
Arts & Crafts
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Record Number 30730
Arts & Crafts
There is not enough clear floor space at the sink.
Finding 44.00 inches
Code At least 48.00 inches
CA 11B-606.2
ovide enough clear floor space at the location.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$900
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 78 of 853
Record Number 30731
Arts & Crafts
There is not enough clear floor space at the sink.
Finding 29.00 inches
Code At least 30.00 inches
ADA 4.27
,ovide enough clear floor space at the location.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$900
$0.00
Record Number 30732
Arts & Crafts
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$180
$0.00
Record Number 30739
Health Center
Sink counter height is not compliant.
Finding 36.00 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
Provide compliant sink.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 79 of 853
Record Number 30740
Health Center
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$420
$0.00
Record Number 30741
Health Center
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Record Number 30742
Health Center
There is not enough clear floor space at the sink.
Finding 29.50 inches
Code At least 30.00 inches
ADA 4.27
ovide enough clear floor space at the location.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$900
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 80 of 853
Record Number 30743
Health Center
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$180
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30685
Picnic Tables
The required percentage of picnic tables provided are not
accessible.
Finding None Found
Code At least 1.00 tables
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
provide a sufficient number of compliant picnic tables.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$500
$0.00
Accessible Showers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30586
Girls Locker Room Shower
There is no folding seat in the accessible shower.
Finding No Seat
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant folding seat in the accessible shower.
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$1,068
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 81 of 853
Record Number 30588
Girls Locker Room Shower
The grab bar is mounted on walls over the seat.
Finding Over Seat
ADA 4.21.4, CA 11B-609, CA 11B-608.3
ove the grab bar so that it is mounted on walls opposite and
ijacent to the front edge of the seat, but not extended to
'elude that portion of wall over the seat.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,840
$0.00
Record Number 30587
Girls Locker Room Shower
There is no hand-held sprayer unit in the shower designated to be
accessible.
Finding None Found
ADA 4.21, ADA 4.21.6, CA 11B-608.6
rovide a compliant hand-held sprayer unit with a hose.
riority Six
esolution Not Set
rogress Not_Started
,assignment Not Set
$385
$0.00
Record Number 30589
Girls Locker Room Shower
The operational force required to operate the water valve is not
compliant
Finding Not Accessible
ADA 4.21.5, CA 11B-608.5, CA 11B-309.4
rovide an accessible water control device that can be operated
ith one hand and a compliant pounds of force to operate.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$554
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 82 of 853
Record Number 30590
Girls Locker Room Shower
The water valve distance from seat wall is not compliant.
Finding 41.75 inches
Code 18.00 - 24.00 inches
ADA 4.21.5, CA 11B-608.5
rovide a compliant water valve.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,500
$0.00
Record Number 30625
Boys Locker Room Shower
Shower seat width is not compliant.
Finding 14.37 inches
Code 15.00 - 22.00 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant shower seat.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,500
$0.00
Record Number 30626
Boys Locker Room Shower
The distance between the folding seat and the adjacent wall is not
compliant.
Finding 1.75 inches
Code Up to 1.50 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant shower seat.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 83 of 853
Record Number 30624
Boys Locker Room Shower
The grab bar is mounted on walls over the seat.
Finding Over Seat
ADA 4.21.4, CA 11B-609, CA 11B-608.3
ove the grab bar so that it is mounted on walls opposite and
ijacent to the front edge of the seat, but not extended to
'elude that portion of wall over the seat.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,840
$0.00
Record Number 30623
Boys Locker Room Shower
There is no hand-held sprayer unit in the shower designated to be
accessible.
Finding None Found
ADA 4.21, ADA 4.21.6, CA 11B-608.6
rovide a compliant hand-held sprayer unit with a hose.
riority Six
esolution Not Set
rogress Not_Started
,assignment Not Set
$385
$0.00
Record Number 30627
Boys Locker Room Shower
The operational force required to operate the water valve is not
compliant
Finding Not Accessible
ADA 4.21.5, CA 11B-608.5, CA 11B-309.4
rovide an accessible water control device that can be operated
ith one hand and a compliant pounds of force to operate.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$554
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 84 of 853
Record Number 30628
Boys Locker Room Shower
The water valve distance from seat wall is not compliant.
Finding 41.00 inches
Code 18.00 - 24.00 inches
ADA 4.21.5, CA 11B-608.5
rovide a compliant water valve.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,500
$0.00
Record Number 30810
Shower In Unisex Staff Restroom
There are not enough accessible showers with respect to the total
number of showers available.
Finding None Found
Code At least 1.00 showers
ADA 4.21.2, CA 11B-213.3.6
rovide the required amount of compliant accessible showers.
riority Six
esolution Not Set
rogress Not_Started
,assignment Not Set
$4,500
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30647
Community Room
Powerade Vending Machine
The forward reach height of the controls on the vending machine
is greater than the allowed maximum height.
Finding 52.25 inches
Code Up to 48.00 inches
ADA 4.2.5
''ontact the owner of the vending machines to obtain accessible
znding machines.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 85 of 853
Record Number 30648
Community Room
Snack Vending Machine
The forward reach height of the controls on the vending machine
is greater than the allowed maximum height.
Finding 52.75 inches
Code Up to 48.00 inches
ADA 4.2.5
ontact the owner of the vending machines to obtain accessible
=nding machines.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$0.00
Record Number 30649
Community Room
Snack Vending Machine
The controls of the vending machine require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.2.5
°eplace controls of vending machine with those that allow
oeration with one hand and does not require tight grasping,
inching, or twisting of the wrist.
riority Seven
esolution Not Set
rogress Not_Started
,ssignment Not Set
$550
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 86 of 853
City Of La Quinta Sports Complex
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29565
Accessible Parking
Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 103.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 29566
Accessible Parking
Accessible Space
The slope of the accessible parking space is not compliant.
Finding 3.20 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
riority Seven
.esolution Not Set
'regress Not_Started
.assignment Not Set
$3,800
$0.00
Record Number 29567
Accessible Parking
Accessible Space
The access aisle does not meet the minimum required width.
Finding 91.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
e-stripe the access aisle.
riority Three
.esolution Not Set
'regress Not_Started
assignment Not Set
$250
$0.00
Path of Travel
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 87 of 853
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29537
Path Of Travel From The Public Right Of Way
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 2.60 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
rovide a compliant path of travel.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$3,600
$0.00
Record Number 29570
Path Of Travel To Baseball Fields
Open Area
The path of travel is grass, dirt, or gravel, preventing access to
individuals with mobility impairments.
Finding Dirt, Grass or Gravel
ADA 4.5.1, CA 11B-302.1, CA 11B-403.2
Provide an accessible route.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$1,840
$0.00
Record Number 29586
Path to Path Of Travel From The Accessible Space
Crosswalk From The Access Aisle
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
rovide detectable warnings.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$190
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 88 of 853
Record Number 29609
rovide an intermediate handrail spaced equally in the middle of
le stair run.
$1,528
$0.00
Stairs To The Baseball Field Next To The Concession Stand
Run 1
There is no intermediate handrail available; the width of the
stairway requires that a middle handrail is installed.
Finding None Found
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 27990
Concession Stand
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$0.00
Record Number 29571
Womens Restroom
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 89 of 853
Record Number 29577
Main Office
Pull Side
There is no level landing at this door.
Finding 2.90 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
tiority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
$1,500
$0.00
Record Number 29576
Main Office
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 29574
Main Office
Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
lstall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
Priority Four
.esolution Corrected
'rogress Completed
,ssignment Not Set
12/15/2015
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 90 of 853
Record Number 29573
Main Office
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
12/15/2015
$25
$0.00
Record Number 29575
Main Office
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Corrected
'rogress Completed
Assignment Not Set
12/15/2015
$50
$0.00
Record Number 29606
Mens Restroom
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
.ssignment Not Set
12/15/2015
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 91 of 853
Record Number 29607
Mens Restroom
Push / Pull
Door hardware is not mounted at the correct height.
Finding 48.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Three
esolution Corrected
'rogress Completed
assignment Not Set
12/15/2015
$280
$0.00
Record Number 29608
Mens Restroom
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 28805
South Mens Restroom
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 92 of 853
Record Number 28806
Gate To Baseball Field On The North Side Of The Concession
Stand
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
tiority Four
.esolution Corrected
'rogress Completed
,ssignment Not Set
12/15/2015
$400
$0.00
Record Number 28809
Gate To The Baseball Field On South Side Of The Concession
Stand
Push Side
There is no level landing at this door.
Finding 99.00 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
tiority Five
.esolution Corrected
'rogress Completed
assignment Not Set
12/15/2015
$1,500
$0.00
Record Number 28807
Gate To The Baseball Field On South Side Of The Concession
Stand
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Install a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
Priority Four
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 93 of 853
Record Number 28808
Gate To The Baseball Field On South Side Of The Concession
Stand
The height of the threshold at the entrance door is greater than
allowed.
Finding 3.50 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Corrected
'rogress Completed
Assignment Not Set
12/15/2015
$436
$0.00
Record Number 28835
South Womens Restroom
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
Modify or replace the threshold to provide the recommended
i leight.
riority Four
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
$436
$0.00
Record Number 28844
Mens Restroom Next To Concession Stand
The height of the threshold at the entrance door is greater than
allowed for a vertical rise.
Finding 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
Modify or replace the threshold to provide the recommended
neight.
riority Seven
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
$257
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 94 of 853
Record Number 27401
Gate To Baseball Field D
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 55.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,921
$0.00
Record Number 27400
Gate To Baseball Field D
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Tnstall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Corrected
'rogress Completed
.ssignment Not Set
12/15/2015
$400
$0.00
Record Number 27434
Gate To Fields 2 And 3
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Install a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 95 of 853
Record Number 27435
Gate To Fields 2 And 3
odify or replace the threshold to provide the recommended
eight.
12/15/2015
$436
$0.00
The height of the threshold at the entrance door is greater than
allowed.
Finding 2.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11 B-404.2. 5
°riority Four
.esolution Corrected
rogress Completed
Assignment Not Set
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29605
Food Counter At Concession Stand
The height of the counter or desk does not comply with height
requirements.
Finding 34.50 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$3,500
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29548
Main Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
)stall compliant room identification signage.
riority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
12/15/2015
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 96 of 853
Record Number 27402
Concession Stand
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$158
$0.00
Record Number 28911
Directional Signage From The Public Right Of Way To The
Concession Area
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Not Set
'rogress Not_Started
,assignment Not Set
$158
$0.00
Record Number 29856
Directional Signage To The Baseball Fields
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
install directional signage to each accessible element or room.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 97 of 853
Record Number 29539
Mens Restroom
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 57.00 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,707
$0.00
Record Number 29547
Mens Restroom
The height of the side grab bar is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Record Number 29545
Mens Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 49.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 98 of 853
Record Number 29546
Mens Restroom
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 20.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 29541
Mens Restroom
The height of the toilet seat is not at the required height.
Finding 15.00 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
Adjust or modify the toilet so the seat height is at the required
:cessible height.
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,707
$0.00
Record Number 29540
Mens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.00 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
tiority Five
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 99 of 853
Record Number 29543
Mens Restroom
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$127
$0.00
Record Number 29544
Mens Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 37.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Five
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
$2,500
$0.00
Record Number 29578
Womens Restroom
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 56.00 inches
Code At least 60.00 inches
ADA 4.16.2
Provide a compliant clearance around the water closet
measured perpendicular from the rear wall.
tiority Five
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
$1,707
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 100 of 853
Record Number 29584
Womens Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 48.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
priority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 29585
Womens Restroom
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 19.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
12/15/2015
$267
$0.00
Record Number 29582
Womens Restroom
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
Relocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$127
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 101 of 853
Record Number 29583
Womens Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 38.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Five
.esolution Not Set
'regress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 29580
Womens Restroom
The height of the toilet seat is not at the required height.
Finding 16.00 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
riority Five
.esolution Not Set
'regress Not_Started
.ssignment Not Set
$1,707
$0.00
Record Number 29579
Womens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 102 of 853
Record Number 29588
Womens Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
tiority Five
.esolution Not Set
'regress Not_Started
Assignment Not Set
$1,286
$0.00
Record Number 29589
Womens Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
°rovide compliant signage on latch side of door.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 29587
Womens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 49.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
^elocate the dispenser to the correct height.
tiority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 103 of 853
Record Number 29593
Mens Restroom
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
priority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$280
$0.00
Record Number 29597
Mens Restroom
The height of the urinal rim in the restroom is not compliant.
Finding 17.25 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
Lower the urinal designated to be accessible in the restroom so
iat the rim height is compliant.
riority Five
.esolution Not Set
'regress Not_Started
assignment Not Set
$1,397
$0.00
Record Number 29598
Mens Restroom
The height of the urinal flush control in the restroom is greater
than the required maximum height.
Finding 34.00 inches
Code At least 44.00 inches
ADA 4.18.4, CA 11B-605.4
Lower the flush control valve on the urinal to a height not
reater than the required maximum height.
riority Five
.esolution Not Set
'regress Not_Started
.ssignment Not Set
$227
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 104 of 853
Record Number 29596
Mens Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.25 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,286
$0.00
Record Number 29600
Mens Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
°rovide compliant signage on latch side of door.
riority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
12/15/2015
$158
$0.00
Record Number 29599
Mens Restroom
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.50 inches
Code 60.00 inches
CA 11B-703.7.2.6
'lost gender use signage on the center of the door at the
quired height.
riority Three
.esolution Corrected
'rogress Completed
_.ssignment Not Set
12/15/2015
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 105 of 853
Record Number 29594
Mens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 50.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Three
.esolution Corrected
'rogress Completed
,ssignment Not Set
12/15/2015
$277
$0.00
Record Number 29595
Mens Restroom
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Three
.esolution Corrected
'rogress Completed
,ssignment Not Set
12/15/2015
$277
$0.00
Record Number 28813
South Womens Restroom
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 61.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Post gender use signage on the center of the door at the
?quired height.
Priority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 106 of 853
Record Number 28812
South Womens Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 28814
South Womens Restroom
The signage is not mounted at the required height.
Finding 61.00 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
tiority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 28811
South Womens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Three
.esolution Corrected
'rogress Completed
assignment Not Set
12/15/2015
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 107 of 853
Record Number 28817
South Mens Restroom
The height of the urinal flush control in the restroom is greater
than the required maximum height.
Finding 43.00 inches
Code At least 44.00 inches
ADA 4.18.4, CA 11B-605.4
)wer the flush control valve on the urinal to a height not
reater than the required maximum height.
priority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$227
$0.00
Record Number 28818
South Mens Restroom
The urinal in the restroom does not provide a tapered, elongated
rim.
Finding Not Tapered
ADA 4.18.2
eplace the urinal designated to be accessible in the restroom
ith a wall -mounted or compartment -type tapered, elongated
m unit.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$951
$0.00
Record Number 28820
South Mens Restroom
The signage is not mounted at the required height.
Finding 61.00 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
post compliant signage at the restroom.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 108 of 853
Record Number 28819
South Mens Restroom
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 61.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 28816
South Mens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
°elocate the dispenser to the correct height.
Priority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
12/15/2015
$277
$0.00
Record Number 28840
Mens Restroom Next To The Concession Stand
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
^elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
tiority Three
.esolution Corrected
'rogress Completed
ssignment Not Set
12/15/2015
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 109 of 853
Record Number 28843
Mens Restroom Next To The Concession Stand
The coat hook is not mounted at the correct height.
Finding 53.00 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$50
$0.00
Record Number 28842
Mens Restroom Next To The Concession Stand
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 28875
Womens Restroom Next To The Concession Stand
The signage is not mounted at the required height.
Finding 60.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Dst compliant signage at the restroom.
°riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 110 of 853
Record Number 28873
Womens Restroom Next To The Concession Stand
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 28874
Womens Restroom Next To The Concession Stand
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 28877
South Mens Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Five
.esolution Not Set
'regress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 111 of 853
Record Number 28887
South Womens Restroom
The height of the side grab bar is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Record Number 28888
South Womens Restroom
The grab bar on the rear wall is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$231
$0.00
Record Number 28891
Mens Restroom Next To The Concession Stand
The height of the urinal flush control in the restroom is greater
than the required maximum height.
Finding 43.00 inches
Code At least 44.00 inches
ADA 4.18.4, CA 11B-605.4
)wer the flush control valve on the urinal to a height not
reater than the required maximum height.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$227
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 112 of 853
Record Number 28892
Mens Restroom Next To The Concession Stand
The urinal in the restroom does not provide a tapered, elongated
rim.
Finding Not Tapered
ADA 4.18.2
eplace the urinal designated to be accessible in the restroom
ith a wall -mounted or compartment -type tapered, elongated
m unit.
tiority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
$951
$0.00
Record Number 28893
Mens Restroom Next To The Concession Stand
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 60.50 inches
Code 60.00 inches
CA 11B-703.7.2.6
Post gender use signage on the center of the door at the
quired height.
tiority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 28894
Mens Restroom Next To The Concession Stand
The signage is not mounted at the required height.
Finding 60.50 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Dst compliant signage at the restroom.
tiority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 113 of 853
Record Number 28890
Mens Restroom Next To The Concession Stand
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 28896
Womens Restroom Next To The Concession Stand
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 45.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$277
$0.00
Record Number 28900
Womens Restroom Next To The Concession Stand
The coat hook is not mounted at the correct height.
Finding 53.00 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
Mount the coat hook at the recommended height.
riority Three
.esolution Not Set
'regress Not_Started
.ssignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 114 of 853
Record Number 28899
Womens Restroom Next To The Concession Stand
The grab bar on the rear wall is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$231
$0.00
Record Number 28898
Womens Restroom Next To The Concession Stand
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 34.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28838
Drinking Fountain Next To The Concession Entrance
Drinking fountain does not provide a required fountain depth.
Finding 12.00 inches
Code At least 15.00 inches
ADA 4.15.5, CA 11B-602.8
Install a drinking fountain the meets the required minimum
2pth.
Priority Five
esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 115 of 853
Record Number 28837
Drinking Fountain Next To The Concession Entrance
The spout outlet height is greater than required.
Finding 39.00 inches
Code Up to 36.00 inches
ADA 4.15.2, CA 11B-602.4
rovide a spout outlet that does not exceed the required height.
riority Five
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$627
$0.00
Record Number 28839
Drinking Fountain Next To The Concession Entrance
The drinking fountain is not set entirely in an alcove.
Finding None Found
CA 11B-602.9
rovide compliant wing walls or barrier at the drinking fountain.
riority Five
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$640
$0.00
Record Number 28836
Drinking Fountain Next To The Concession Entrance
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
riority Five
.esolution Corrected
'rogress Completed
.,ssignment Not Set
12/15/2015
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 116 of 853
Record Number 27367
Drinking Fountain Between Baseball Fields 1 And 2
The spout outlet height is greater than required.
Finding 37.00 inches
Code Up to 36.00 inches
ADA 4.15.2, CA 11B-602.4
rovide a spout outlet that does not exceed the required height.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$627
$0.00
Record Number 27368
Drinking Fountain Between Baseball Fields 1 And 2
The distance from the front edge of the unit (including bumpers)
to the spout location, is greater than the allowed maximum
distance.
Finding 7.00 inches
Code Up to 6.00 inches
ADA 4.15.3, CA 11B-602.5
rovide a fountain with the spout location a compliant distance
om the front of the fountain to the flow of the water.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 27365
Drinking Fountain Between Baseball Fields 1 And 2
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
Replace the drinking fountain with a compliant High/Low
fountain.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 117 of 853
Record Number 27366
Drinking Fountain Between Baseball Fields 1 And 2
The drinking fountain is not on accessible route.
Finding None Found
ADA 4.15.5
ake sure the drinking fountain is on an accessible route.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,840
$0.00
Record Number 28909
Drinking Fountain Next To The Concession Office
Drinking fountain does not provide a required fountain depth.
Finding 12.00 inches
Code At least 15.00 inches
ADA 4.15.5, CA 11B-602.8
(stall a drinking fountain the meets the required minimum
epth.
riority Five
esolution Corrected
'rogress Completed
.ssignment Not Set
12/15/2015
$2,500
$0.00
Record Number 28906
Drinking Fountain Next To The Concession Office
The spout outlet height is greater than required.
Finding 40.00 inches
Code Up to 36.00 inches
ADA 4.15.2, CA 11B-602.4
Provide a spout outlet that does not exceed the required height.
°riority Five
esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$627
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 118 of 853
Record Number 28907
Drinking Fountain Next To The Concession Office
The height of the water stream is less than required.
Finding 3.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
djust the flow of the water stream to a compliant height.
riority Five
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$2,500
$0.00
Record Number 28910
Drinking Fountain Next To The Concession Office
The drinking fountain is not set entirely in an alcove.
Finding None Found
CA 11B-602.9
rovide compliant wing walls or barrier at the drinking fountain.
riority Five
.esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$640
$0.00
Record Number 28904
Drinking Fountain Next To The Concession Office
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
tiority Three
.esolution Corrected
'rogress Completed
.,ssignment Not Set
12/15/2015
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 119 of 853
Record Number 28905
Drinking Fountain Next To The Concession Office
The drinking fountain is a protruding object.
Finding None
ADA 4.15.5, CA 11B-602, CA 11B-307.2
ake sure that the fountain is not a protruding object.
riority Five
esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$550
$0.00
Record Number 28908
Drinking Fountain Next To The Concession Office
The clear floor space slope is not compliant.
Finding 2.90 percent
Code Up to 2.00 percent
ADA 4.15.5, CA 11B-602.2
rovide compliant clear floor space at the drinking fountain.
riority Seven
esolution Corrected
rogress Completed
Assignment Not Set
12/15/2015
$2,200
$0.00
Assembly Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29538
Upper Baseball Field
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 2.00 seats
CA 11B-221.2, CA 11B-802.1
rovide a compliant amount of accessible seats.
riority Five
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 120 of 853
Record Number 29569
Lower Baseball Field
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 4.00 seats
CA 11B-221.2, CA 11B-802.1
rovide a compliant amount of accessible seats.
riority Five
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$600
$0.00
Record Number 27418
Baseball Field 2
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 4.00 seats
CA 11B-221.2, CA 11B-802.1
rovide a compliant amount of accessible seats.
riority Five
esolution Not Set
rogress Not_Started
,assignment Not Set
$600
$0.00
Record Number 27471
Baseball Field D
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 2.00 seats
CA 11B-221.2, CA 11B-802.1
Provide a compliant amount of accessible seats.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 121 of 853
Record Number 27473
Baseball Field 5
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 4.00 seats
CA 11B-221.2, CA 11B-802.1
rovide a compliant amount of accessible seats.
riority Five
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$600
$0.00
Record Number 27474
Baseball Field 3
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 4.00 seats
CA 11B-221.2, CA 11B-802.1
rovide a compliant amount of accessible seats.
riority Five
.esolution Not Set
rogress Not_Started
,assignment Not Set
$600
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28810
South Womens Restroom
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
Install visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Six
.esolution Not Set
rogress Not_Started
,assignment Not Set
$2,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 122 of 853
Record Number 28815
South Mens Restroom
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$2,200
$0.00
Record Number 28872
Womens Restroom Next To The Concession Stand
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,200
$0.00
Record Number 28889
Mens Restroom Next To The Concession Stand
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,200
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 123 of 853
Record Number 28864
Sink In The Concession Stand
Sink counter height is not compliant.
Finding 35.50 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,800
$0.00
Record Number 28865
Sink In The Concession Stand
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
$420
$0.00
Record Number 28866
Sink In The Concession Stand
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 124 of 853
Record Number 28867
Sink In The Concession Stand
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$180
$0.00
Record Number 28868
Sink In The Concession Stand
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$180
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 27977
Picnic Tables Next To The South Restrooms
No ISA Symbol was found at the picnic table.
Finding None Found
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
Add a compliant ISA symbol at the picnic table.
riority Three
.esolution Not Set
rogress Not_Started
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 125 of 853
Record Number 28895
Picnic Tables In Front Of The Concession Stand
No ISA Symbol was found at the picnic table.
Finding None Found
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
dd a compliant ISA symbol at the picnic table.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 27303
Benches Next To Harry S. Truman Elementary School
The bench back rest height is not compliant.
Finding 12.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
djust the bench back rest height to recommended value.
riority Four
.esolution Corrected
rogress Completed
,ssignment Not Set
12/15/2015
$800
$0.00
Record Number 27369
Benches At The Batting Cages
The bench back rest height is not compliant.
Finding 12.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
^,djust the bench back rest height to recommended value.
riority Four
.esolution Corrected
rogress Completed
.ssignment Not Set
12/15/2015
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 126 of 853
Civic Center
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43043
Employees Parking Lot
Parking Lot Warning Sign
Signage height from the finished floor is not compliant.
Finding 28.37 inches
Code At least 36.00 inches
CA 11B-502.8
rovide compliant signage at a compliant height.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$110
$0.00
Record Number 43015
Employees Parking Lot
1st Row Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 101.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43016
Employees Parking Lot
1st Row Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 127 of 853
Record Number 43017
Employees Parking Lot
1st Row Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43018
Employees Parking Lot
1st Row Left Accessible Space
The height of the wall -mounted signage at the accessible space is
not compliant.
Finding 28.25 inches
Code At least 36.00 inches
ADA 4.6.4, CA 11B-502.6
Demount the wall -mounted signage at the accessible parking
Jace at a compliant height.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43019
Employees Parking Lot
3rd Row Right Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 101.87 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
Re -stripe the accessible parking space.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 128 of 853
Record Number 43020
Employees Parking Lot
3rd Row Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43021
Employees Parking Lot
3rd Row Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43023
Employees Parking Lot
2nd Row Right Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 102.25 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 129 of 853
Record Number 43024
Employees Parking Lot
2nd Row Right Accessible Space
The accessible parking space does not meet the minimum
requirement for length.
Finding 194.00 inches
Code At least 216.00 inches
CA 11B-502.2
e-stripe the accessible parking space.
tiority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43022
Employees Parking Lot
2nd Row Right Accessible Space
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
Re -stripe the existing parking space marked as accessible to
'efine the width of the space.
tiority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43025
Employees Parking Lot
2nd Row Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
tiority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 130 of 853
Record Number 43027
Employees Parking Lot
2nd Row Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43026
Employees Parking Lot
2nd Row Right Accessible Space
ISA surface identification is faded and not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.6.4
Repaint the ISA surface identification in the parking space.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$117
$0.00
Record Number 43028
Employees Parking Lot
2nd Row Right Accessible Space
The height of the wall -mounted signage at the accessible space is
not compliant.
Finding 28.00 inches
Code At least 36.00 inches
ADA 4.6.4, CA 11B-502.6
Demount the wall -mounted signage at the accessible parking
Jace at a compliant height.
riority Seven
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 131 of 853
Record Number 43029
Employees Parking Lot
2nd Row Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 101.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43030
Employees Parking Lot
2nd Row Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
lternational Symbol of Accessibility.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43032
Employees Parking Lot
2nd Row Left Accessible Space
The height of the wall -mounted signage at the accessible space is
not compliant.
Finding 28.50 inches
Code At least 36.00 inches
ADA 4.6.4, CA 11B-502.6
emount the wall -mounted signage at the accessible parking
Jace at a compliant height.
Priority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 132 of 853
Record Number 43031
Employees Parking Lot
2nd Row Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
tiority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43033
Employees Parking Lot
2nd Row Left Accessible Space
The access aisle does not meet the minimum required width.
Finding 95.75 inches
Code At least 96.00 inches
ADA 4.1.2(5)
De -stripe the access aisle.
tiority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43034
Employees Parking Lot
2nd Row Left Accessible Space
The access aisle markings are faded, damaged, or otherwise not
viewable.
Finding None Found
CA 11B-502.3
De -stripe the access aisle so as to discourage parking.
tiority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 133 of 853
Record Number 43035
Employees Parking Lot
1st Row Right Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 107.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43036
Employees Parking Lot
1st Row Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
lternational Symbol of Accessibility.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43038
Employees Parking Lot
1st Row Right Accessible Space
The designated accessible parking space does not provide
accessible signage at the head of the space.
Finding None Found
ADA 4.6.4
Provide compliant sigange at the accessible space.
riority Seven
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 134 of 853
Record Number 43039
Employees Parking Lot
1st Row Right Accessible Space
The height of the wall -mounted signage at the accessible space is
not compliant.
Finding 28.75 inches
Code At least 36.00 inches
ADA 4.6.4, CA 11B-502.6
emount the wall -mounted signage at the accessible parking
Jace at a compliant height.
tiority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43037
Employees Parking Lot
1st Row Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
°rovide compliant surface identification at the accessible parking
Dace.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43040
Employees Parking Lot
3rd Row Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 101.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
Re -stripe the accessible parking space.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 135 of 853
Record Number 43041
Employees Parking Lot
3rd Row Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43042
Employees Parking Lot
3rd Row Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43073
Visitors Parking Lot
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Three
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 136 of 853
Record Number 43074
Visitors Parking Lot
South Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 105.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43075
Visitors Parking Lot
South Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
lternational Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43076
Visitors Parking Lot
South Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
Priority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 137 of 853
Record Number 43077
Visitors Parking Lot
South Accessible Space
The height of the wall -mounted signage at the accessible space is
not compliant.
Finding 17.00 inches
Code At least 36.00 inches
ADA 4.6.4, CA 11B-502.6
emount the wall -mounted signage at the accessible parking
Jace at a compliant height.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43078
Visitors Parking Lot
South Accessible Space
The access aisle does not meet the minimum required width.
Finding 92.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
De -stripe the access aisle.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43079
Visitors Parking Lot
South Accessible Space
The access aisle does not contain the wording "No Parking"
painted in white letters within the access aisle.
Finding None Found
CA 11B-502.3.3
paint the words "NO PARKING" a compliant height within the
:cess aisle.
tiority Three
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 138 of 853
Record Number 43080
Visitors Parking Lot
North Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 103.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43081
Visitors Parking Lot
North Accessible Space
The accessible parking space does not meet the minimum
requirement for length.
Finding 215.75 inches
Code At least 216.00 inches
CA 11B-502.2
Re -stripe the accessible parking space.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43082
Visitors Parking Lot
North Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 139 of 853
Record Number 43086
Visitors Parking Lot
North Accessible Space
The access aisle does not meet the minimum required width.
Finding 92.25 inches
Code At least 96.00 inches
ADA 4.1.2(5)
e-stripe the access aisle.
tiority Three
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$250
$0.00
Record Number 43088
Visitors Parking Lot
North Accessible Space
The access aisle does not contain the wording "No Parking"
painted in white letters within the access aisle.
Finding None Found
CA 11B-502.3.3
aint the words "NO PARKING' a compliant height within the
:cess aisle.
tiority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Record Number 43085
Visitors Parking Lot
North Accessible Space
The access aisle is not located on the passenger side of the
parking space.
Finding See Above
ADA 4.6.3
rovide a compliant access aisle on the passenger side of the
:cessible parking space.
tiority Three
.esolution Not Set
'rogress Not_Started
..ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 140 of 853
Record Number 43084
Visitors Parking Lot
North Accessible Space
The height of the wall -mounted signage at the accessible space is
not compliant.
Finding 16.37 inches
Code At least 36.00 inches
ADA 4.6.4, CA 11B-502.6
emount the wall -mounted signage at the accessible parking
Jace at a compliant height.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43083
Visitors Parking Lot
North Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
°rovide compliant surface identification at the accessible parking
Dace.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$220
$0.00
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43146
Curb Ramp From The Employee Parking Lot
The running slope is greater than allowed.
Finding 10.10 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
°rovide a compliant curb ramp.
riority Four
.esolution Not Set
rogress Not_Started
ssignment Not Set
06/30/2013
$1,s,..
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 141 of 853
Record Number 43253
1st Curb Ramp On Path Of Travel From Washington Street
The running slope is greater than allowed.
Finding 9.30 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
rovide a compliant curb ramp.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43254
1st Curb Ramp On Path Of Travel From Washington Street
The cross slope is greater than allowed.
Finding 3.00 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.7
rovide a compliant curb ramp.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43256
1st Curb Ramp On Path Of Travel From Washington Street
Bottom Landing
The transition from the bottom of the curb ramp to the walk,
gutter, or street is abrupt.
Finding Not Beveled
ADA 4.5.2, CA 11B-406.5.8
atch the transition area at the bottom of the curb ramp so that
le transition is flush and free of abrupt changes.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$255
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 142 of 853
Record Number 43255
1st Curb Ramp On Path Of Travel From Washington Street
Bottom Landing
The transition from the bottom of the curb ramp to the walk,
gutter, or street is abrupt.
Finding 0.50 inches
Code Up to 0.25 inches
ADA 4.5.2, ADA 406.5.8
atch the transition area at the bottom of the curb ramp so that
le transition is flush and free of abrupt changes.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$255
$0.00
Record Number 43257
1st Curb Ramp On Path Of Travel From Washington Street
Top Landing
The transition from the top of the curb ramp to the walk, gutter,
or street is abrupt.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.5.2, CA 11B-406.5.6
°atch the transition area at the top of the curb ramp so that the
ansition is flush and free of abrupt changes.
riority Four
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$155
$0.00
Record Number 43295
2nd Curb Ramp On Path Of Travel From Washington Street
Bottom Landing
The transition from the bottom of the curb ramp to the walk,
gutter, or street is abrupt.
Finding Not Beveled
ADA 4.5.2, CA 11B-406.5.8
Patch the transition area at the bottom of the curb ramp so that
He transition is flush and free of abrupt changes.
riority Not Set
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$255
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 143 of 853
Record Number 43294
atch the transition area at the bottom of the curb ramp so that
le transition is flush and free of abrupt changes.
06/30/2013
$255
$0.00
2nd Curb Ramp On Path Of Travel From Washington Street
Bottom Landing
The transition from the bottom of the curb ramp to the walk,
gutter, or street is abrupt.
Finding 0.50 inches
Code Up to 0.25 inches
ADA 4.5.2, ADA 406.5.8
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
Record Number 43296
2nd Curb Ramp On Path Of Travel From Washington Street
Top Landing
The slope at the top landing is greater than allowed.
Finding 2.60 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.3
°rovide a top landing that has a compliant slope and
ianeuvering space.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,260
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43429
Path Of Travel Near EOC
Stretcher
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 9.37 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
(stall side extensions, modify, relocate, or lower the item so
'at it is not a protruding object into the circulation route.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$64G
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 144 of 853
Record Number 42968
Path Of Travel At The Entrances
Floor Mats
The mats or carpet runners do not adhere to the underlying floor
surface and slip, thereby creating a hazardous path of travel.
Finding Not Accessible
ADA 4.5.3, CA 11B-403.2, CA 11B-302
ecurely fasten the mats or carpet runners or replace with a
la or carpet runner that grips to the underlying floor surface
provide a firm, stable, and slip resistant path of travel.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$42
$0.00
Record Number 42987
Path Of Travel From Calle Tampico
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 5.80 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
Provide a compliant path of travel.
tiority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$3,600
$0.00
Record Number 43046
Path Of Travel From The Accessible Spaces In The Visitors Lot
Path Of Travel From The Access Aisle
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
Provide detectable warnings.
tiority Three
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 145 of 853
Record Number 43047
Path Of Travel From The Accessible Spaces In The Visitors Lot
Path Of Travel From The Access Aisle
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
rovide a compliant crosswalk.
tiority Three
esolution Not Set
togress Not_Started
assignment Not Set
06/30/2013
$1,100
$0.00
Record Number 43176
Path Of Travel From Washington Street
Path Of Travel Crosses Traffic
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
rovide a compliant crosswalk.
tiority Three
esolution Not Set
togress Not_Started
Assignment Not Set
06/30/2013
$1,100
$0.00
Record Number 43319
Path Of Travel To The Area 5 South Entrance
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 6.40 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
Provide a compliant path of travel.
tiority Five
esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 146 of 853
Record Number 42985
Path Of Travel To The Planning Department
Fire Extinguisher
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 4.50 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
(stall side extensions, modify, relocate, or lower the item so
'at it is not a protruding object into the circulation route.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$640
$0.00
Record Number 43008
Path Of Travel In Hallway 155
Automated External Defibrillator
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 5.25 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
Tnstall side extensions, modify, relocate, or lower the item so
lat it is not a protruding object into the circulation route.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$640
$0.00
Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43065
Ramp From Calle Tampico
Run 1
The ramp run does not provide adequate edge protection to
prevent individuals from slipping off the ramp.
Finding None Found
ADA 4.8.7, CA 11B-405.9
Tnstall compliant edge protection on each side of the ramp run.
Priority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
.)-+iu
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 147 of 853
Record Number 43066
Ramp From Calle Tampico
Run 1 Bottom Landing
The slope of the landing is greater than required.
Finding 5.00 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-405.7.1
odify the landing to create a slope in any direction not
Kceeding the required maximum value.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,872
$0.00
Record Number 43069
Ramp From Calle Tampico
Run 1 Right Handrail
The height of the handrail on the ramp is not a compliant height
above the surface of the ramp.
Finding 33.75 inches
Code 34.00 - 38.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.4
odify or replace the handrail on the ramp to provide a
)mpliant gripping surface height.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$3,918
$0.00
Record Number 43068
Ramp From Calle Tampico
Run 1 Right Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Five
esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 148 of 853
Record Number 43067
Ramp From Calle Tampico
Run 1 Right Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
tiority Five
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,400
$0.00
Record Number 43071
Ramp From Calle Tampico
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,400
$0.00
Record Number 43070
Ramp From Calle Tampico
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
provide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
ie bottom of the ramp and return smoothly to the post or wall.
4riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 149 of 853
Record Number 43222
Ramp To The Area 4 Patio
Run 1
The slope of the ramp is greater than the allowed slope.
Finding 8.60 percent
Code Up to 8.33 percent
ADA 4.8.2, CA 11B-405.2
odify the run of the ramp to provide the required slope and
-oss slope.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$3,600
$0.00
Record Number 43223
Ramp To The Area 4 Patio
Run 2 Top Landing
The length of the top landing does not meet the required
minimum length.
Finding 48.50 inches
Code At least 60.00 inches
CA 11B-405.7.3
odify or replace the top landing to provide the required
iinimum length and width.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,872
$0.00
Record Number 43224
Ramp To The Area 4 Patio
Run 2 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
Finding 9.50 inches
Code At least 12.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 150 of 853
Record Number 43230
Ramp At The South Entrance To The Lobby
Run 1
The ramp run does not provide adequate edge protection to
prevent individuals from slipping off the ramp.
Finding None Found
ADA 4.8.7, CA 11B-405.9
(stall compliant edge protection on each side of the ramp run.
tiority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$470
$0.00
Record Number 43231
Ramp At The South Entrance To The Lobby
Run 1 Bottom Landing
The slope of the landing is greater than required.
Finding 3.30 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-405.7.1
Modify the landing to create a slope in any direction not
xceeding the required maximum value.
riority Five
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$2,872
$0.00
Record Number 43234
Ramp At The South Entrance To The Lobby
Run 1 Left Handrail
The height of the handrail on the ramp is not a compliant height
above the surface of the ramp.
Finding 33.75 inches
Code 34.00 - 38.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.4
odify or replace the handrail on the ramp to provide a
)mpliant gripping surface height.
Priority Five
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$3,918
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 151 of 853
Record Number 43232
Ramp At The South Entrance To The Lobby
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Five
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,400
$0.00
Record Number 43233
Ramp At The South Entrance To The Lobby
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
Finding 11.00 inches
Code At least 12.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,400
$0.00
Record Number 43236
Ramp At The South Entrance To The Lobby
Run 1 Right Handrail
The height of the handrail on the ramp is not a compliant height
above the surface of the ramp.
Finding 33.50 inches
Code 34.00 - 38.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.4
Modify or replace the handrail on the ramp to provide a
compliant gripping surface height.
riority Five
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$3,918
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 152 of 853
Record Number 43235
Ramp At The South Entrance To The Lobby
Run 1 Right Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
tiority Five
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,400
$0.00
Record Number 43237
Ramp To EOC/Police 151
Run 1
The ramp run does not provide adequate edge protection to
prevent individuals from slipping off the ramp.
Finding None Found
ADA 4.8.7, CA 11B-405.9
Install compliant edge protection on each side of the ramp run.
tiority Five
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$470
$0.00
Record Number 43238
Ramp To EOC/Police 151
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
Finding 11.50 inches
Code At least 12.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
Provide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
Priority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 153 of 853
Record Number 43240
Ramp To EOC/Police 151
Run 1 Right Handrail
The surface of the wall adjacent to the handrail is abrasive.
Finding Abrasive
ADA 4.26.4
odify the surface of the wall adjacent to the handrail so that
le surface is smooth and nonabrasive.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,320
$0.00
Record Number 43239
Ramp To EOC/Police 151
Run 1 Right Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
Finding 11.50 inches
Code At least 12.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,400
$0.00
Record Number 43244
Ramp To The Study Session Room
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
Priority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 154 of 853
Record Number 43245
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
06/30/2013
$2,400
$0.00
Ramp To The Study Session Room
Run 1 Right Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
riority Five
.esolution Not Set
rogress Not_Started
..ssignment Not Set
Elevators
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43392
Area 5 Elevator
There is no signage at the elevator indicating the evacuation plan.
Finding None Found
ADA 4.10
"rovide compliant signage indicating evacuation plan and
)utes.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$207
$0.00
Record Number 43393
Area 5 Elevator
The main entrance floor is not identified with a star to the left of
the control button.
Finding Not Accessible
ADA 4.10.12, CA 11B-407.4.7.1.3
,ontact a certified elevator provider to perform all renovation
quired.
riority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 155 of 853
Record Number 43394
Area 5 Elevator
The reopening device for the elevator door does not remain open
for the required amount of time.
Finding Not Accessible
ADA 4.10.6, CA 11B-407.3.3.3
ontact a certified elevator provider to perform all renovation
?quired.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Record Number 43395
Area 5 Elevator
Elevator communication control mounting height is not compliant.
Finding 31.37 inches
Code 35.00 - 48.00 inches
ADA 4.10.14, CA 11B-308, CA 11B-407.4.9
°rovide communication controls at a compliant height. Contact
a certified elevator provider to perform all renovation required.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,200
$0.00
Record Number 43396
Area 5 Elevator
The hoistway signage is not at a compliant height above the
finished floor.
Finding 59.87 inches on center
Code 60.00 inches on center
ADA 4.10.5, CA 11B-407.2.3.1
'rovide compliant signage within the elevator hoistways.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 156 of 853
Record Number 43397
Area 5 Elevator
Braille is not located immediately below the raised letters.
Finding None Found
ADA 4.10.5
rovide compliant signage that has the braille located
imediately below the raised letters.
riority Four
esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43398
Area 5 Elevator
Main floor is not indicated with a star.
Finding None Found
ADA 4.10.5
ake sure that main floor is indicated with a star.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$180
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43433
Stairwell Near The Elevator
Run 2 Left Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 11.25 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
Tnstall a compliant handrail extension to the top of the handrail
iat extends beyond the top riser and is parallel to the floor
arface of the landing.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 157 of 853
Record Number 43434
Stairwell Near The Elevator
Run 2 Right Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 8.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
(stall a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Record Number 43435
Stairwell Near The Elevator
Run 2 Right Handrail
The bottom handrail does not extend the depth of one stair tread
beyond the bottom step.
Finding None Found
ADA 4.9.4(2), CA 11B-505.10.3
Provide a compliant handrail extension.
tiority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$1,425
$0.00
Record Number 43436
Stairwell Near The Elevator
Run 1
The stair striping is not at a compliant distance from the nosing.
Finding 1.87 inches
Code At least 2.00 inches
ADA 4.9.5, CA 11B-504.4.1
Affix compliant contrasting striping to the upper approach and
ach tread that is the correct width and distance from the
Dsing.
tiority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$460
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 158 of 853
Record Number 43437
Stairwell Near The Elevator
Run 1 Left Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 10.50 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
(stall a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
tiority Four
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Record Number 43212
Southwest Stairs
Run 1
The striping on each tread of the stairway is not at a compliant
width.
Finding 1.25 inches
Code Up to 1.00 inches
ADA 4.9.5, CA 11B-504.4.1
Provide compliant striping on each tread of the stairway.
tiority Three
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$460
$0.00
Record Number 43213
Southwest Stairs
Run 1 Right Handrail
The handrail extension is not the required length.
Finding 4.50 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.3
Install a compliant extension to the handrail.
tiority Four
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$627
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 159 of 853
Record Number 43251
Stairs To Receiving 154
Run 1 Left Handrail
The handrail is not mounted at the required height.
Finding 32.00 inches
Code 34.00 - 38.00 inches
ADA 4.9.4(5), CA 11B-504.6, CA 11B-505
rovide handrail at the required height.
tiority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$1,528
$0.00
Record Number 43250
Stairs To Receiving 154
Run 1 Left Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 5.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
(stall a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Record Number 43252
Stairs To Receiving 154
Run 1 Right Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 3.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
)stall a compliant handrail extension to the top of the handrail
lat extends beyond the top riser and is parallel to the floor
arface of the landing.
Priority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 160 of 853
Record Number 43259
Stairs To The Area 4 Patio
Run 1
There is no intermediate handrail available; the width of the
stairway requires that a middle handrail is installed.
Finding None Found
rovide an intermediate handrail spaced equally in the middle of
le stair run.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,528
$0.00
Record Number 43186
Left Stairs In The Council Chambers 101
Run 1
The width of the stairway does not meet the minimum required
width.
Finding 41.50 inches
Code At least 44.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
Tnstall a stairway with a minimum width as required.
Priority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$4,816
$0.00
Record Number 43187
Left Stairs In The Council Chambers 101
Run 1
There is no detectable striping on the stairways.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
"ffix compliant contrasting striping to the upper approach and
ach tread that is the correct width and distance from the
Dsing.
riority Three
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$1,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 161 of 853
Record Number 43188
Left Stairs In The Council Chambers 101
Run 1 Left Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 7.25 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
(stall a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Record Number 43274
Right Stairs In The Council Chambers 101
Run 1
The width of the stairway does not meet the minimum required
width.
Finding 42.25 inches
Code At least 44.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
Install a stairway with a minimum width as required.
riority Six
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$4,816
$0.00
Record Number 43275
Right Stairs In The Council Chambers 101
Run 1
There is no detectable striping on the stairways.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
Affix compliant contrasting striping to the upper approach and
ach tread that is the correct width and distance from the
Dsing.
riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$1,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 162 of 853
Record Number 43422
West Stairwell
Run 1
The width of the stairway does not meet the minimum required
width.
Finding 43.00 inches
Code At least 44.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
(stall a stairway with a minimum width as required.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$4,816
$0.00
Record Number 43423
West Stairwell
Run 1 Left Handrail
The surface texture of the wall adjacent to the handrail is sharp
and abrasive.
Finding Near Wall
ADA 4.26.4
Modify the surface texture on the wall adjacent to the handrail
D that the surface is smooth.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,320
$0.00
Record Number 43424
West Stairwell
Run 2
The width of the stairway does not meet the minimum required
width.
Finding 43.00 inches
Code At least 44.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
)stall a stairway with a minimum width as required.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$4,816
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 163 of 853
Record Number 43425
West Stairwell
Run 2
The stair striping is not at a compliant distance from the nosing.
Finding 1.87 inches
Code At least 2.00 inches
ADA 4.9.5, CA 11B-504.4.1
ffix compliant contrasting striping to the upper approach and
3ch tread that is the correct width and distance from the
Dsing.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$460
$0.00
Record Number 43426
West Stairwell
Run 2 Right Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 5.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
Tnstall a compliant handrail extension to the top of the handrail
lat extends beyond the top riser and is parallel to the floor
arface of the landing.
riority Four
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43386
Basement Stairwell Door Near EOC
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 13.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 164 of 853
Record Number 43409
EOC Mens & Womens Restroom
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43413
EOC Staff Lounge
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43414
EOC Staff Lounge
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 165 of 853
Record Number 43419
EOC
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43420
EOC
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 42991
Exterior Doors From The Courtyard
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 166 of 853
Record Number 43101
New Addition Area 1 Exterior Door
Pull Side
There is no level landing at this door.
Finding 2.90 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
tiority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43100
New Addition Area 1 Exterior Door
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Record Number 43099
New Addition Area 1 Exterior Door
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
tiority Two
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 167 of 853
Record Number 43104
Exterior Door To Receiving 154
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Record Number 43102
Exterior Door To Receiving 154
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43103
Exterior Door To Receiving 154
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 168 of 853
Record Number 43123
Main Lobby South Entrance
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 38.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43122
Main Lobby South Entrance
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
°emove the door stop.
tiority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43159
Exterior Door To The Council Chambers
Push / Pull
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
tiority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 169 of 853
Record Number 43178
Exterior Doors To The Area 4 Patio
Pull Side
There is no level landing at this door.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
tiority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43177
Exterior Doors To The Area 4 Patio
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43219
Exterior Door Near The Computer Room 141
There is no specific signage for the automatic door.
Finding No Signage
ANSI/BHMA A156.19, ADA 404
Provide compliant caution automatic door signage.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 170 of 853
Record Number 43220
Exterior Door Near The Computer Room 141
The automatic door does not hold open for the minimum required
time.
Finding See Above
ANSI/BHMA A156.19, ADA 404
djust the automatic door so the force to stop the door from
osing is no more than allowed.
priority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43221
Exterior Door Near The Computer Room 141
There is no level landing at this Automatic door.
Finding 2.50 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing for the automatic door.
riority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,040
$0.00
Record Number 43268
East Entrance To The Area 4 Sessions Room
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 171 of 853
Record Number 43269
East Entrance To The Area 4 Sessions Room
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Record Number 43273
Staff Lounge 180 Patio
Pull Side
There is no level landing at this door.
Finding 3.10 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43271
Staff Lounge 180 Patio
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 172 of 853
Record Number 43272
Staff Lounge 180 Patio
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Record Number 43341
North Entrance To The West Lobby
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43342
South Employee Entrance To The West Lobby
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 15.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 173 of 853
Record Number 43343
South Employee Entrance To The West Lobby
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Record Number 43356
Exterior Doors Near The Mayors Office
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 12.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43357
Exterior Doors Near The Mayors Office
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 174 of 853
Record Number 42948
Mens Locker Room 176
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 16.75 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$4,000
$0.00
Record Number 42947
Mens Locker Room 176
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Record Number 42967
Hallway Door To EOC/Police 151
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 0.62 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
nrovide the recommended latch side clearance on the push side
F the door.
riority Five
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 175 of 853
Record Number 42965
Hallway Door To EOC/Police 151
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 42966
Hallway Door To EOC/Police 151
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 42977
Doors In The New Addition Area 1 Engineer Offices
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 176 of 853
Record Number 42982
Mens Staff Restroom 177 & Womens Staff Restroom 179
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 47.00 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$4,000
$0.00
Record Number 42981
Mens Staff Restroom 177 & Womens Staff Restroom 179
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Record Number 42983
Door From Public Works 200 To The New Addition Area 1
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 11.50 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide required latch side clearance on the pull side of the
Dor.
riority Seven
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 177 of 853
Record Number 42986
Hallway Doors Near Plan Checker 162 & Parks 170
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Record Number 42988
South Conference Room 138, East Conference Room 167, &
North Conference Room 190
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 52.25 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
riority Five
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$2,921
$0.00
Record Number 42989
Mens Lobby Restroom 130
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
. equirements.
riority Two
.esolution Not Set
rogress Not_Started
..ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 178 of 853
Record Number 42990
Mens Lobby Restroom 130
Push / Pull
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
tiority Three
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$280
$0.00
Record Number 43007
Rear Hallway Door To The Production Office 183
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 14.50 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
tiority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43004
Rear Hallway Door To The Production Office 183
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Four
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 179 of 853
Record Number 43005
Rear Hallway Door To The Production Office 183
Single Knob
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43006
Rear Hallway Door To The Production Office 183
Single Knob
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43011
Hallway Door 155
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 12.75 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 180 of 853
Record Number 43009
Hallway Door 155
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43010
Hallway Door 155
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Corrected
'rogress Completed
Assignment Not Set
02/27/2012
02/27/2012
$50
$0.00
Record Number 43012
Doorway From The Lobby To The Finance Counters
The clear opening width of the door is less than required.
Finding 31.25 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Seven
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 181 of 853
Record Number 43013
Doorway From The Lobby To The Finance Counters
Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
lstall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$400
$0.00
Record Number 43014
Swinging Gates Near The Service Counters
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Tnstall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$400
$0.00
Record Number 43051
Door Between Mens Locker Room 176 & Restroom 177
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 58.25 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
Provide the recommended clear floor space on the pull side of
He door.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 182 of 853
Record Number 43050
Door Between Mens Locker Room 176 & Restroom 177
Push / Pull
Door hardware is not mounted at the correct height.
Finding 44.25 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
tiority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$280
$0.00
Record Number 43062
Womens Lobby Restroom 131
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43063
Womens Lobby Restroom 131
Push / Pull
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
Mount the door hardware at the recommended height.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 183 of 853
Record Number 43064
Door Between Womens Locker Room 178 & Restroom 179
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43089
Hallway Door To Receiving 154
Lever
The door opening force for this door is greater than allowed.
Finding 15.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43090
Hallway Door To Receiving 154
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 184 of 853
Record Number 43117
Accessible Showers In The Mens & Womens Locker Rooms
176 & 178
The vertical clearance height of the door is less than required.
Finding 67.62 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
tend the height of the doorway to provide the required
earance height.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,000
$0.00
Record Number 43120
Accessible Showers In The Mens & Womens Locker Rooms
176 & 178
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 46.12 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43119
Accessible Showers In The Mens & Womens Locker Rooms
176 & 178
The height of the threshold at the entrance door is greater than
allowed for a vertical rise.
Finding 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
1 Ieight.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$257
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 185 of 853
Record Number 43118
Accessible Showers In The Mens & Womens Locker Rooms
176 & 178
Finger Pull - 1.5
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Record Number 43134
Door Between Recieving 154 & EOC/Police 151
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 10.00 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
Provide required latch side clearance on the pull side of the
' Dor.
tiority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43136
Front Door To The Production Office 183
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 186 of 853
Record Number 43137
Front Door To The Production Office 183
Single Knob
Door hardware is not mounted at the correct height.
Finding 46.25 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
tiority Three
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$280
$0.00
Record Number 43179
Main Office Production Room
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43181
Womens Locker Room 178
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 16.75 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 187 of 853
Record Number 43180
Womens Locker Room 178
Push / Pull
Door hardware is not mounted at the correct height.
Finding 58.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
tiority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$280
$0.00
Record Number 43190
Exercise Room Near The Staff Lounge
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Record Number 43189
Exercise Room Near The Staff Lounge
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
tiority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 188 of 853
Record Number 43193
Door From The Main Lobby To The West Wing
Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$400
$0.00
Record Number 43194
Caucus Room
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 2.12 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
°rovide required latch side clearance on the pull side of the
Dor.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43195
Main Office
Lever
The door opening force for this door is greater than allowed.
Finding 13.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
quirements.
riority Two
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 189 of 853
Record Number 43196
Main Office
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
tiority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Record Number 43210
Area 4 Session Room
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43211
Area 4 Session Room
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
tiority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 190 of 853
Record Number 43214
Lobby Door To The Council Chambers 101
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43215
Lobby Door To The Council Chambers 101
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43227
Rear Door To The Council Chambers 101
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 44.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the pull side of
le door.
Priority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 191 of 853
Record Number 43226
Rear Door To The Council Chambers 101
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Record Number 43225
Rear Door To The Council Chambers 101
Lever
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$280
$0.00
Record Number 43242
Council Chambers 101 Audio Visual Room
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 5.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
Priority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 192 of 853
Record Number 43243
Council Chambers 101 Audio Visual Room
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 23.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the pull side of
le door.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43241
Council Chambers 101 Audio Visual Room
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
°emove the door stop.
tiority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43246
Main Office Computer Room
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 7.25 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide required latch side clearance on the pull side of the
Dor.
tiority Five
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 193 of 853
Record Number 43249
Hallway Door Near The Main Lobby South Entrance
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 17.12 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43248
Hallway Door Near The Main Lobby South Entrance
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
°emove the door stop.
tiority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43247
Hallway Door Near The Main Lobby South Entrance
Push Bar / D Handle
Door hardware is not mounted at the correct height.
Finding 44.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
"'bunt the door hardware at the recommended height.
tiority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 194 of 853
Record Number 43258
Production Room 146
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 47.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43264
Offices 132A & B
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 47.75 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
°rovide the recommended clear floor space on the push side of
le door.
riority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43265
Offices 132A & B
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 42.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
Provide the recommended clear floor space on the pull side of
He door.
riority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 195 of 853
Record Number 43266
Staff Lounge 180
Lever
The door opening force for this door is greater than allowed.
Finding 12.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43293
Office Near Womens Restroom 111
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 2.75 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43299
Mens & Womens Restrooms In Area 4 Sessions Room
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 196 of 853
Record Number 43324
Hallway Door From The Main lobby To The City Mangers
Office
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Record Number 43325
Hallway Door From The Main lobby To The City Mangers
Office
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
°emove the door stop.
Priority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43330
Hallway Door Near The Area 5 Police Office
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 9.75 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide required latch side clearance on the pull side of the
Dor.
riority Five
.esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 197 of 853
Record Number 43345
Hallway Door Near Womens Restroom 111
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 6.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43346
Hallway Door Near Womens Restroom 111
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 5.00 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
°rovide required latch side clearance on the pull side of the
Dor.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43344
Hallway Door Near Womens Restroom 111
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
quirements.
riority Two
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 198 of 853
Record Number 43355
Mens & Womens Restrooms In The West Lobby
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43379
Hallway Door To The City Managers Marketing Offices
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43380
Hallway Door To The City Managers Marketing Offices
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 199 of 853
Record Number 43408
Stairwell Door Near The Elevator
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 5.12 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43406
Stairwell Door Near The Elevator
Push / Pull
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Record Number 43407
Stairwell Door Near The Elevator
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
^emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 200 of 853
Record Number 43415
Exterior Stairwell Door Near The Elevator
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 10.50 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43416
Exterior Stairwell Door Near The Elevator
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43417
Exterior Stairwell Door Near The Elevator
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 201 of 853
Record Number 43349
Mayors Reception Counter
The height of the counter or desk does not comply with height
requirements.
Finding 41.87 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Three
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$3,500
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 42984
Exterior Doors From The Courtyard
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
Tnstall compliant room identification signage.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43121
North & South Entrances To The Lobby
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
Tnstall accessible room signage.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 202 of 853
Record Number 43135
Directional Signage From The Public Right Of Way
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43045
Room Identification Signage
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43132
EOC/Police 151
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 59.87 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 203 of 853
Record Number 43270
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
06/30/2013
$50
$0.00
Caucus Room
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 59.87 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
riority Three
.esolution Not Set
rogress Not_Started
.assignment Not Set
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43383
EOC Womens Restroom
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43384
EOC Womens Restroom
The door to the compartment swings inward into the minimum
required compartment area.
Finding Swings In
ADA 4.17.3, CA 11B-604.8.1
odify the swing of the door so that it does not swing into the
iinimum required compartment area.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 204 of 853
Record Number 43385
EOC Womens Restroom
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 15.00 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43381
EOC Womens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.87 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43403
EOC Mens Restroom
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 205 of 853
Record Number 43404
EOC Mens Restroom
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 43405
EOC Mens Restroom
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43401
EOC Mens Restroom
The height of the side grab bar is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
priority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 206 of 853
Record Number 43402
EOC Mens Restroom
The grab bar on the rear wall is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Record Number 43399
EOC Mens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43428
EOC Mens Restroom
The urinal does not meet the requirement for the minimum
projection from the back wall to the front of the urinal rim.
Finding 13.50 inches
Code At least 14.00 inches
ADA 4.18.2, CA 11B-605.2
(stall a urinal that meets the minimum projection
?quirements.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$951
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 207 of 853
Record Number 43427
EOC Mens Restroom
The top of the mirror is not at the compliant height.
Finding 73.75 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43431
EOC Womens Restroom
The top of the mirror is not at the compliant height.
Finding 73.37 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43430
EOC Womens Restroom
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.25 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 208 of 853
Record Number 43432
EOC Womens Restroom
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 60.25 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 42953
Mens Staff Restroom 177
The shields extend greater than 24" in front of the urinal. The
width between the shields is less than required.
Finding 35.50 inches
Code At least 36.00 inches
ADA 4.18.2, CA 11B-605.3, CA 11B-305.7
"lodify or replace the urinal shields in the restroom to provide
le required clearance between the shields for the urinal
esignated as accessible.
riority Six
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$1,800
$0.00
Record Number 42951
Mens Staff Restroom 177
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.75 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
_ 'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 209 of 853
Record Number 42952
Mens Staff Restroom 177
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$149
$0.00
Record Number 42955
Mens Staff Restroom 177
The signage is not mounted at the required height.
Finding 59.87 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 42956
Mens Staff Restroom 177
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
)stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 210 of 853
Record Number 42954
Mens Staff Restroom 177
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 42950
Mens Staff Restroom 177
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 42962
Mens Staff Restroom 177
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Provide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 211 of 853
Record Number 42963
Mens Staff Restroom 177
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
priority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 42964
Mens Staff Restroom 177
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 42960
Mens Staff Restroom 177
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 212 of 853
Record Number 42969
Womens Lobby Restroom 131
There is insufficient clear floor space in the compartment.
Finding 59.75 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
odify or replace the compartment to provide adequate clear
Dor space.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 42973
Womens Lobby Restroom 131
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 42974
Womens Lobby Restroom 131
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Adjust the inside handle so that it is located near the latch.
°riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 213 of 853
Record Number 42970
Womens Lobby Restroom 131
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 42972
Womens Lobby Restroom 131
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.25 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 42993
Mens Lobby Restroom 130
There is insufficient clear floor space in the compartment.
Finding 59.50 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
odify or replace the compartment to provide adequate clear
Dor space.
riority Seven
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 214 of 853
Record Number 42997
Mens Lobby Restroom 130
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
priority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 42998
Mens Lobby Restroom 130
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 42999
Mens Lobby Restroom 130
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Adjust the inside handle so that it is located near the latch.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 215 of 853
Record Number 43000
Mens Lobby Restroom 130
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 16.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
priority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 42994
Mens Lobby Restroom 130
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 42996
Mens Lobby Restroom 130
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 216 of 853
Record Number 43057
Womens Staff Restroom 179
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43058
Womens Staff Restroom 179
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43059
Womens Staff Restroom 179
The signage is not mounted at the required height.
Finding 59.87 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 217 of 853
Record Number 43060
Womens Staff Restroom 179
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43055
Womens Staff Restroom 179
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43056
Womens Staff Restroom 179
Feminine Products
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 218 of 853
Record Number 43094
Mens Lobby Restroom 130
There is less than the required clear floor space provided in front
of the urinal in the restroom to allow an accessible forward
approach.
Finding 29.50 inches
Code At least 30.00 inches
ADA 4.18.3, CA 11B-605.3, CA 11B-305.3
rovide the required minimum clear floor space in front of the
rinal designated to be accessible in the restroom, for a forward
Dproach.
riority Six
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,707
$0.00
Record Number 43095
Mens Lobby Restroom 130
The urinal center line is not compliant.
Finding 12.87 inches
Code At least 15.00 inches
ADA 4.18.2, CA 11B-605.3
Provide a compliant urinal with recommended values.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,300
$0.00
Record Number 43096
Mens Lobby Restroom 130
The shields extend greater than 24" in front of the urinal. The
width between the shields is less than required.
Finding 27.12 inches
Code At least 36.00 inches
ADA 4.18.2, CA 11B-605.3, CA 11B-305.7
odify or replace the urinal shields in the restroom to provide
le required clearance between the shields for the urinal
esignated as accessible.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 219 of 853
Record Number 43097
Mens Lobby Restroom 130
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43098
Mens Lobby Restroom 130
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43092
Mens Lobby Restroom 130
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.61 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
erogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 220 of 853
Record Number 43093
Mens Lobby Restroom 130
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43091
Mens Lobby Restroom 130
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$277
$0.00
Record Number 43127
Womens Lobby Restroom 131
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.87 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
Raise or replace the lavatory to provide the minimum required
Dron height.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 221 of 853
Record Number 43128
Womens Lobby Restroom 131
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.25 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
esolution Not Set
_-rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43129
Womens Lobby Restroom 131
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
abrasive surfaces under the lavatory.
riority Two
esolution Not Set
rogress Not_Started
ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43130
Womens Lobby Restroom 131
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Post gender use signage on the center of the door at the
-quired height.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 222 of 853
Record Number 43131
Womens Lobby Restroom 131
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43124
Womens Lobby Restroom 131
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43125
Womens Lobby Restroom 131
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 223 of 853
Record Number 43126
Womens Lobby Restroom 131
Feminine Products
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43138
Womens Staff Restroom 179
There is insufficient clear floor space in the compartment.
Finding 59.75 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
Modify or replace the compartment to provide adequate clear
_. Dor space.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43142
Womens Staff Restroom 179
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 224 of 853
Record Number 43143
Womens Staff Restroom 179
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
priority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 43144
Womens Staff Restroom 179
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43139
Womens Staff Restroom 179
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 225 of 853
Record Number 43141
Womens Staff Restroom 179
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43145
Womens Staff Restroom 179
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 17.00 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43148
EOC/Police Unisex Staff Restroom 152
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 226 of 853
Record Number 43147
EOC/Police Unisex Staff Restroom 152
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
°riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$804
$0.00
Record Number 43149
EOC/Police Unisex Staff Restroom 152
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$280
$0.00
Record Number 43150
EOC/Police Unisex Staff Restroom 152
The entrance door swings into the turning space within the
restroom.
Finding 28.75 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$8,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 227 of 853
Record Number 43155
EOC/Police Unisex Staff Restroom 152
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Record Number 43157
EOC/Police Unisex Staff Restroom 152
The signage is not mounted at the required height.
Finding 59.50 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Dst compliant signage at the restroom.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43158
EOC/Police Unisex Staff Restroom 152
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Seven
esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 228 of 853
Record Number 43152
EOC/Police Unisex Staff Restroom 152
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 26.50 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
iron height.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43153
EOC/Police Unisex Staff Restroom 152
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 22.25 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,286
$0.00
Record Number 43154
EOC/Police Unisex Staff Restroom 152
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Seven
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 229 of 853
Record Number 43156
EOC/Police Unisex Staff Restroom 152
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43151
EOC/Police Unisex Staff Restroom 152
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43160
Mens Restroom 110
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
Provide a compliant door lock for the door that does not require
ght grasping, pinching, or twisting of the wrist to operate.
riority Four
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 230 of 853
Record Number 43166
Mens Restroom 110
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.62 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
Priority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Record Number 43167
Mens Restroom 110
The top of the mirror is not at the compliant height.
Finding 73.12 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43163
Mens Restroom 110
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 22.50 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
Priority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 231 of 853
Record Number 43164
Mens Restroom 110
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
.-rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43165
Mens Restroom 110
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
abrasive surfaces under the lavatory.
riority Two
.esolution Not Set
rogress Not_Started
ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43162
Mens Restroom 110
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 26.75 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
Raise or replace the lavatory to provide the minimum required
oron height.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 232 of 853
Record Number 43168
Mens Restroom 110
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43169
Mens Restroom 110
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43161
Mens Restroom 110
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 233 of 853
Record Number 43171
EOC/Police Unisex Staff Restroom 152
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 46.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43170
EOC/Police Unisex Staff Restroom 152
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43173
EOC/Police Unisex Staff Restroom 152
The height of the toilet seat is not at the required height.
Finding 19.50 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,707
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 234 of 853
Record Number 43172
EOC/Police Unisex Staff Restroom 152
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43175
EOC/Police Unisex Staff Restroom 152
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 32.87 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43184
Mens Restroom In Area 4 Sessions Room
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 36.62 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 235 of 853
Record Number 43182
Mens Restroom In Area 4 Sessions Room
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.25 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43185
Mens Restroom In Area 4 Sessions Room
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 13.00 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43207
Womens Restroom In Area 4 Sessions Room
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 236 of 853
Record Number 43208
Womens Restroom In Area 4 Sessions Room
The entrance door swings into the turning space within the
restroom.
Finding 29.12 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$8,200
$0.00
Record Number 43209
Womens Restroom In Area 4 Sessions Room
The top of the mirror is not at the compliant height.
Finding 73.25 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43218
Womens Restroom In Area 4 Sessions Room
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 19.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser at a compliant height and
location.
riority Three
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 237 of 853
Record Number 43217
Womens Restroom In Area 4 Sessions Room
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 38.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43261
Mens Restroom 110
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.37 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43263
Mens Restroom 110
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 34.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 238 of 853
Record Number 43280
Womens Restroom 111
The grab bar on the rear wall is not at the correct height.
Finding 32.75 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Record Number 43277
Womens Restroom 111
The height of the toilet seat is not at the required height.
Finding 20.00 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
riority Six
esolution Not Set
'regress Not_Started
.ssignment Not Set
06/30/2013
$1,707
$0.00
Record Number 43276
Womens Restroom 111
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 239 of 853
Record Number 43279
Womens Restroom 111
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 30.37 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43281
Womens Restroom 111
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 16.75 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43301
Mens Restroom In Area 4 Sessions Room
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 240 of 853
Record Number 43302
Mens Restroom In Area 4 Sessions Room
The entrance door swings into the turning space within the
restroom.
Finding 30.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$8,200
$0.00
Record Number 43305
Mens Restroom In Area 4 Sessions Room
The top of the mirror is not at the compliant height.
Finding 73.25 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43303
Mens Restroom In Area 4 Sessions Room
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.12 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
Relocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 241 of 853
Record Number 43304
Mens Restroom In Area 4 Sessions Room
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.75 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
_ rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43306
Womens Restroom 111
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
"odify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
a wheelchair.
riority Six
.esolution Not Set
rogress Not_Started
..ssignment Not Set
06/30/2013
$1,800
$0.00
Record Number 43307
Womens Restroom 111
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
Provide a compliant door lock for the door that does not require
ght grasping, pinching, or twisting of the wrist to operate.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 242 of 853
Record Number 43308
Womens Restroom 111
The entrance door swings into the turning space within the
restroom.
Finding 47.50 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$8,200
$0.00
Record Number 43313
Womens Restroom 111
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.62 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
I ower the mirror so the bottom edge of the reflective surface is
i to higher than recommended above the finished floor.
riority Seven
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43314
Womens Restroom 111
The top of the mirror is not at the compliant height.
Finding 73.25 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 243 of 853
Record Number 43310
Womens Restroom 111
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 26.62 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
iron height.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43311
Womens Restroom 111
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 22.50 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,286
$0.00
Record Number 43312
Womens Restroom 111
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 244 of 853
Record Number 43315
Womens Restroom 111
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43316
Womens Restroom 111
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43309
Womens Restroom 111
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 245 of 853
Record Number 43322
City Managers Unisex Restroom
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 17.00 inches
Code Up to 12.00 inches
rovide feminine products disposal at the required distance
om front of the toilet.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43323
City Managers Unisex Restroom
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 12.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43320
City Managers Unisex Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.37 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 246 of 853
Record Number 43338
Mens Restroom In The West Lobby
There is less than the required latch side clearance on the pull side
of the door.
Finding 7.50 inches
Code At least 18.00 inches
ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404
rovide required latch side clearance on the pull side of the
°riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,200
$0.00
Record Number 43335
Mens Restroom In The West Lobby
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43336
Mens Restroom In The West Lobby
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 247 of 853
Record Number 43337
Mens Restroom In The West Lobby
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43333
Mens Restroom In The West Lobby
The height of the side grab bar is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43334
Mens Restroom In The West Lobby
The grab bar on the rear wall is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 248 of 853
Record Number 43339
Mens Restroom In The West Lobby
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 13.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43331
Mens Restroom In The West Lobby
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.87 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43340
Womens Restroom In The West Lobby
The top of the mirror is not at the compliant height.
Finding 73.37 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
priority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 249 of 853
Record Number 43347
Mens Restroom In The West Lobby
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.25 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,286
$0.00
Record Number 43348
Mens Restroom In The West Lobby
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 61.12 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43350
City Managers Unisex Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
)stall a compliant privacy lock with occupancy indicator to the
Dor.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$804
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 250 of 853
Record Number 43353
City Managers Unisex Restroom
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
3st gender use signage on the center of the door at the
?quired height.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43354
City Managers Unisex Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Seven
.esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$158
$0.00
Record Number 43352
City Managers Unisex Restroom
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.50 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 251 of 853
Record Number 43370
Womens Restroom In The West Lobby
There is insufficient clear floor space in the compartment.
Finding 59.75 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
odify or replace the compartment to provide adequate clear
Dor space.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43377
Womens Restroom In The West Lobby
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 16.87 inches
Code Up to 12.00 inches
rovide feminine products disposal at the required distance
om front of the toilet.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43373
Womens Restroom In The West Lobby
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 252 of 853
Record Number 43374
Womens Restroom In The West Lobby
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
priority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 43375
Womens Restroom In The West Lobby
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43376
Womens Restroom In The West Lobby
There is less than the required latch side clearance on the pull side
of the door.
Finding 8.25 inches
Code At least 18.00 inches
ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404
rovide required latch side clearance on the pull side of the
Dor.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 253 of 853
Record Number 43372
Womens Restroom In The West Lobby
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43378
Womens Restroom In The West Lobby
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 12.87 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43002
Drinking Fountain Near Womens Staff Restroom 179
The height of the water stream is less than required.
Finding 1.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
djust the flow of the water stream to a compliant height.
riority Six
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 254 of 853
Record Number 43003
Drinking Fountain Near Womens Staff Restroom 179
There is not enough clear floor space for a parallel approach in an
alcove.
Finding 50.50 inches
Code At least 60.00 inches
ADA 4.2.4.2, CA 11B-602.2, CA 11B-305.7.2
rovide the required clear floor space or reduce the depth of
le alcove.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$108
$0.00
Record Number 43001
Drinking Fountain Near Womens Staff Restroom 179
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$2,500
$0.00
Assembly Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43260
Council Chambers 101
There are not enough accessible seats at the location with respect
to the total number of seats available.
Finding None Found
Code At least 4.00 seats
CA 11B-221.2, CA 11B-802.1
"rovide a compliant amount of accessible seats.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$600
$0.00
Locker Rooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 255 of 853
Record Number 43048
Mens Locker Room 176
No International Symbol of Accessibility is found at the accessible
locker.
Finding None Found
ADA 4.35
esignate the accessible locker with the International Symbol of
ccessibility.
°riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$58
$0.00
Record Number 43049
Mens Locker Room 176
The height of the bench is not compliant.
Finding 19.50 inches
Code 17.00 - 19.00 inches
ADA 4.35.4, ADA 4.37, CA 11B-803.4, CA 11B-903.5, CA 11B-222
(stall a compliant bench in the locker room. Provide sufficient
ear floor space alongside the the bench to allow a person
sing a wheelchair to transfer on to the bench.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43229
Womens Locker Room 178
There are no accessible benches in the locker room.
Finding None Found
ADA 4.35.4, ADA 4.37
(stall compliant benches in the locker room.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 256 of 853
Record Number 43228
Womens Locker Room 178
esignate the accessible locker with the International Symbol of
ccessibility.
06/30/2013
$58
$0.00
No International Symbol of Accessibility is found at the accessible
locker.
Finding None Found
ADA 4.35
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43206
Womens Restroom In Area 4 Sessions Room
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
Tnstall visual warning devices integrated with the facility's alarm
istem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Six
esolution Not Set
rogress Not_Started
..ssignment Not Set
06/30/2013
$2,200
$0.00
Record Number 43300
Mens Restroom In Area 4 Sessions Room
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
Tnstall visual warning devices integrated with the facility's alarm
istem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Six
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$2,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 257 of 853
Record Number 43351
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
06/30/2013
$2,200
$0.00
City Managers Unisex Restroom
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43389
EOC Staff Lounge
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Tnsulate or otherwise configure the water supply and drain
Ipes under the sink to protect against contact. Make certain
sere are no sharp or abrasive surfaces under the sink.
riority Two
esolution Not Set
rogress Not_Started
..ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43390
EOC Staff Lounge
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
"elocate the dispenser to the correct height.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$110
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 258 of 853
Record Number 43391
EOC Staff Lounge
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 48.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$110
$0.00
Record Number 43387
EOC Staff Lounge
The table knee depth does not meet required standards.
Finding 12.00 inches
Code At least 19.00 inches
ADA 4.27, CA 11B-306, CA 11B-902
Provide compliant tables.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,174
$0.00
Record Number 43388
EOC Staff Lounge
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 259 of 853
Record Number 42949
South Conference Room 138, East Conference Room 167, &
North Conference Room 190
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43072
New Addition Area 1 Conference Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Three
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$158
$0.00
Record Number 43133
Break Room 198
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 51.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Three
esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$110
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 260 of 853
Record Number 43192
Caucus Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 52.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$110
$0.00
Record Number 43191
Caucus Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
Install an International Symbol of Accessibility at the table.
riority Three
.esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$158
$0.00
Record Number 43197
Staff Lounge 180
No visual alarms found at the location.
Finding None Found
ADA 4.27
-ovide visual alarms at the location.
°riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$388
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 261 of 853
Record Number 43202
Staff Lounge 180
The side reach height of the controls on the vending machine is
greater than the allowed maximum height.
Finding 58.00 inches
Code Up to 54.00 inches
ADA 4.2.5, CA 11B-309, CA 11B-228
rovide a compliant vending machine.
riority Seven
esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$0.00
Record Number 43203
Staff Lounge 180
The side reach height of the controls on the vending machine is
greater than the allowed maximum height.
Finding 55.00 inches
Code Up to 54.00 inches
ADA 4.2.5, CA 11B-309, CA 11B-228
rovide a compliant vending machine.
riority Seven
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$0.00
Record Number 43200
Staff Lounge 180
Sink counter height does not meet the standards.
Finding 34.25 inches
Code Up to 34.00 inches
CA 11B-606.3
Provide compliant sink.
priority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 262 of 853
Record Number 43201
Staff Lounge 180
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
ipes under the sink to protect against contact. Make certain
iere are no sharp or abrasive surfaces under the sink.
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 43204
Staff Lounge 180
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 50.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$110
$0.00
Record Number 43205
Staff Lounge 180
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 46.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
Relocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$110
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 263 of 853
Record Number 43198
Staff Lounge 180
The table knee depth does not meet required standards.
Finding 7.00 inches
Code At least 19.00 inches
ADA 4.27, CA 11B-306, CA 11B-902
rovide compliant tables.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,174
$0.00
Record Number 43199
Staff Lounge 180
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Seven
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$158
$0.00
Record Number 43358
West Conference Room
No visual alarms found at the location.
Finding None Found
ADA 4.27
-ovide visual alarms at the location.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$388
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 264 of 853
Record Number 43360
West Conference Room
The toe kick for the sink in break/conference room is not removed.
Finding Not Removed
CA 11B-606.2, CA 11B-305, CA 11B-306
emove the toe kick for the sink.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$612
$0.00
Record Number 43361
West Conference Room
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
ipes under the sink to protect against contact. Make certain
iere are no sharp or abrasive surfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 43359
West Conference Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 265 of 853
Record Number 43366
Staff Lounge Near The Caucus Room
Sink counter height does not meet the standards.
Finding 36.87 inches
Code Up to 34.00 inches
CA 11B-606.3
rovide compliant sink.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Record Number 43367
Staff Lounge Near The Caucus Room
The toe kick for the sink in break/conference room is not removed.
Finding Not Removed
CA 11B-606.2, CA 11B-305, CA 11B-306
emove the toe kick for the sink.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$612
$0.00
Record Number 43368
Staff Lounge Near The Caucus Room
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
1pes under the sink to protect against contact. Make certain
sere are no sharp or abrasive surfaces under the sink.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 266 of 853
Record Number 43369
Staff Lounge Near The Caucus Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 63.87 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$110
$0.00
Record Number 43364
Staff Lounge Near The Caucus Room
The table knee depth does not meet required standards.
Finding 11.00 inches
Code At least 19.00 inches
ADA 4.27, CA 11B-306, CA 11B-902
Provide compliant tables.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,174
$0.00
Record Number 43365
Staff Lounge Near The Caucus Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 267 of 853
Record Number 42957
Sink Near Plan Checker 162
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
aainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 42958
Sink Near Plan Checker 162
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 49.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 42959
Sink Near Plan Checker 162
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 268 of 853
Record Number 42978
Sink Near EOC/Police 157
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
aainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 42979
Sink Near EOC/Police 157
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 49.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 42980
Sink Near EOC/Police 157
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 46.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 269 of 853
Record Number 43052
Sink In The Mens Locker Room 176
Sink counter height is not compliant.
Finding 34.25 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Seven
esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Record Number 43053
Sink In The Mens Locker Room 176
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43054
Sink In The Mens Locker Room 176
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Seven
esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 270 of 853
Record Number 43116
Sink Near Womens Staff Restroom 179
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 54.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43297
Sink In Womens Locker Room 178
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 49.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43298
Sink In Womens Locker Room 178
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'regress Not_Started
_assignment Not Set
06/30/2013
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 271 of 853
Record Number 43318
Sink Near Mens Restroom 110 & Womens Restroom 111
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43362
Sink Near The Mayors Reception Counter
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
Make sure there is no toe kick at the sink.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$420
$0.00
Record Number 43363
Sink Near The Mayors Reception Counter
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 272 of 853
Record Number 43317
Picnic Table At The Staff Lounge 180 Patio
The required percentage of picnic tables provided are not
accessible.
Finding None Found
Code At least 1.00 tables
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
rovide a sufficient number of compliant picnic tables.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$500
$0.00
Accessible Showers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43105
Accessible Shower In The Mens Locker Room 176
The opening width of the shower compartment is less than
required.
Finding 35.62 inches
Code At least 42.00 inches
ADA 4.21.2, CA 11B-608.2
Increase the shower compartment opening to the correct
width.
riority Seven
esolution Not Set
rogress Not_Started
.,ssignment Not Set
06/30/2013
$1,840
$0.00
Record Number 43107
Accessible Shower In The Mens Locker Room 176
The slope of the surface for the shower is not compliant.
Finding 3.10 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-608.9
"epair the floor of the shower to provide a compliant slope.
riority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 273 of 853
Record Number 43106
Accessible Shower In The Mens Locker Room 176
The shower compartment width is not compliant.
Finding 56.00 inches
Code At least 60.00 inches
ADA 4.21.7
odify or replace the shower to provide a compliant accessible
lower compartment.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$3,500
$0.00
Record Number 43110
Accessible Shower In The Mens Locker Room 176
Shower seat length is not compliant.
Finding Not Accessible
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant seat that extends the full length of the
lower.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,068
$0.00
Record Number 43111
Accessible Shower In The Mens Locker Room 176
The distance between the folding seat and the adjacent wall is not
compliant.
Finding 2.37 inches
Code Up to 1.50 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
Provide a compliant shower seat.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 274 of 853
Record Number 43112
Accessible Shower In The Mens Locker Room 176
The folding seat in the accessible shower is not mounted at a
compliant height above the finished floor.
Finding 18.25 inches
Code 18.00 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
emount the folding seat to a compliant height above the
nished floor.
°riority Seven
esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43113
Accessible Shower In The Mens Locker Room 176
The soap dish is not mounted at a compliant height.
Finding 40.50 inches
Code 15.00 - 40.00 inches
CA 11B-608.10
elocated the soap dish on the same wall as the water controls
a compliant height.
riority Seven
esolution Not Set
'regress Not_Started
.ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43109
Accessible Shower In The Mens Locker Room 176
The grab bar is mounted on walls over the seat.
Finding Over Seat
ADA 4.21.4, CA 11B-609, CA 11B-608.3
ove the grab bar so that it is mounted on walls opposite and
ijacent to the front edge of the seat, but not extended to
'elude that portion of wall over the seat.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 275 of 853
Record Number 43108
Accessible Shower In The Mens Locker Room 176
The hand-held sprayer unit is not mounted at the required height
above the finished floor.
Finding 55.00 inches
Code Up to 48.00 inches
ADA 4.21, ADA 4.21.6, CA 11B-608.5
rovide a compliant hand-held sprayer unit with a hose.
riority Seven
esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$385
$0.00
Record Number 43114
Accessible Shower In The Mens Locker Room 176
The water valve distance from seat wall is not compliant.
Finding 34.50 inches
Code 18.00 - 24.00 inches
ADA 4.21.5, CA 11B-608.5
rovide a compliant water valve.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43115
Accessible Shower In The Mens Locker Room 176
The water control valve is not mounted at a compliant height.
Finding 49.50 inches
Code Up to 40.00 inches
ADA 4.21.5, CA 11B-608.5
emount the water control valve.
priority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$554
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 276 of 853
Record Number 43282
Accessible Shower In Womens Locker Room 178
The opening width of the shower compartment is less than
required.
Finding 34.50 inches
Code At least 42.00 inches
ADA 4.21.2, CA 11B-608.2
(crease the shower compartment opening to the correct
idth.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,840
$0.00
Record Number 43284
Accessible Shower In Womens Locker Room 178
The slope of the surface for the shower is not compliant.
Finding 4.00 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-608.9
epair the floor of the shower to provide a compliant slope.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,840
$0.00
Record Number 43283
Accessible Shower In Womens Locker Room 178
The shower compartment width is not compliant.
Finding 57.62 inches
Code At least 60.00 inches
ADA 4.21.7
odify or replace the shower to provide a compliant accessible
lower compartment.
riority Seven
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 277 of 853
Record Number 43286
Accessible Shower In Womens Locker Room 178
The grab bar is mounted on walls over the seat.
Finding Over Seat
ADA 4.21.4, CA 11B-609, CA 11B-608.3
ove the grab bar so that it is mounted on walls opposite and
ijacent to the front edge of the seat, but not extended to
'elude that portion of wall over the seat.
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,840
$0.00
Record Number 43290
Accessible Shower In Womens Locker Room 178
The soap dish is not mounted at a compliant height.
Finding 41.00 inches
Code 15.00 - 40.00 inches
CA 11B-608.10
elocated the soap dish on the same wall as the water controls
a compliant height.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43287
Accessible Shower In Womens Locker Room 178
Shower seat length is not compliant.
Finding Not Accessible
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant seat that extends the full length of the
lower.
riority Seven
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$1,068
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 278 of 853
Record Number 43288
Accessible Shower In Womens Locker Room 178
The distance between the folding seat and the adjacent wall is not
compliant.
Finding 2.25 inches
Code Up to 1.50 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant shower seat.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43289
Accessible Shower In Womens Locker Room 178
The folding seat in the accessible shower is not mounted at a
compliant height above the finished floor.
Finding 19.00 inches
Code 18.00 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
emount the folding seat to a compliant height above the
nished floor.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43285
Accessible Shower In Womens Locker Room 178
The hand-held sprayer unit is not mounted at the required height
above the finished floor.
Finding 55.25 inches
Code Up to 48.00 inches
ADA 4.21, ADA 4.21.6, CA 11B-608.5
rovide a compliant hand-held sprayer unit with a hose.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$385
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 279 of 853
Record Number 43291
Accessible Shower In Womens Locker Room 178
The water valve distance from seat wall is not compliant.
Finding 35.00 inches
Code 18.00 - 24.00 inches
ADA 4.21.5, CA 11B-608.5
rovide a compliant water valve.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43292
Accessible Shower In Womens Locker Room 178
The water control valve is not mounted at a compliant height.
Finding 50.00 inches
Code Up to 40.00 inches
ADA 4.21.5, CA 11B-608.5
emount the water control valve.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$554
$0.00
Record Number 43327
Accessible Shower In The City Managers Office
Either there is no grab bar on the control wall or the length of the
grab bar is not compliant.
Finding 32.00 inches on center
Code 36.00 inches on center
ADA 4.21.4
rovide a compliant grab bar on the control wall.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 280 of 853
Record Number 43328
Accessible Shower In The City Managers Office
Length of grab bar on opposite wall is not compliant.
Finding 21.00 inches
Code At least 24.00 inches
ADA 4.21.4
rovide a compliant grab bar.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43326
Accessible Shower In The City Managers Office
The center line of the hand-held sprayer unit is not a compliant
distance from the rear of the seat edge.
Finding 28.50 inches
Code Up to 27.00 inches
ADA 4.21, ADA 4.21.6, CA 11B-608.5
rovide a compliant hand-held sprayer unit with a hose.
riority Seven
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$385
$0.00
Record Number 43329
Accessible Shower In The City Managers Office
The water control valve is not mounted at a compliant height.
Finding 47.50 inches
Code Up to 40.00 inches
ADA 4.21.5, CA 11B-608.5
demount the water control valve.
priority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$554
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 281 of 853
Record Number 43410
EOC First Aid Kit
Eye Washing Station - Eye Washing Station
The highest point of operation for the element is not compliant.
Finding 62.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Record Number 43411
EOC First Aid Kit
Emergency Lighting Station - Other
The highest point of operation for the element is not compliant.
Finding 63.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Record Number 43412
EOC First Aid Kit
First Aid Kit - Thermostat
The highest point of operation for the element is not compliant.
Finding 72.25 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 282 of 853
Record Number 43418
EOC Staff Lounge Telephone
Telephone - Other
The highest point of operation for the element is not compliant.
Finding 60.75 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Record Number 43421
EOC Computer Station
Computer Station - Computer Station
The knee height is not compliant.
Finding 26.12 inches
Code At least 27.00 inches
ADA 4.2
Hdjust knee height to the recommended value.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43267
First Aid Kit In Staff Lounge 180
First Aid Kit - Other
The highest point of operation for the element is not compliant.
Finding 68.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
'riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$50
$0.00
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 283 of 853
Record Number 42975
Benches
The bench height is not compliant.
Finding 15.25 inches
Code 17.00 - 19.00 inches
ADA 5.8, ADA A4.2.6
djust the bench height to recommended value.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Record Number 42976
Benches
The bench back rest height is not compliant.
Finding 16.87 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench back rest height to recommended value.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Record Number 42992
Benches Near The Planning & Engineering Counters
The bench back rest height is not compliant.
Finding 17.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench back rest height to recommended value.
°riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 284 of 853
Record Number 43044
Benches Near The Finance Counters
The bench back rest height is not compliant.
Finding 17.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
djust the bench back rest height to recommended value.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Record Number 43061
Benches Near The Building & Safety Counters
The bench back rest height is not compliant.
Finding 17.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
djust the bench back rest height to recommended value.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 285 of 853
Fire Station #70
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29193
Parking Off Madison Street
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$250
$0.00
Record Number 29194
Parking Off Madison Street
Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.60 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
riority Seven
.esolution Not Set
'rogress Not_Started
.assignment Not Set
$3,800
$0.00
Record Number 29196
Parking Off Madison Street
Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 286 of 853
Record Number 29195
Parking Off Madison Street
Accessible Space
Parking space signage contains the word handicap.
Finding None Found
ADA 4.6.4, CA 11B-502
rovide compliant signage. Remove the word handicap.
riority Three
.esolution Not Set
rogress Not_Started
assignment Not Set
$300
$0.00
Record Number 29201
Parking Off Madison Street
Accessible Space
The bottom edge of the post -mounted signage designating the
accessible parking space is not at the required height.
Finding 73.00 inches
Code At least 80.00 inches
ADA 4.6.4, CA 11B-502.6
Dst signage at a compliant height.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 29202
Parking Off Madison Street
Accessible Space
The access aisle does not meet the minimum required width.
Finding 92.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
Re -stripe the access aisle.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 287 of 853
Record Number 29203
Parking Off Madison Street
Accessible Space
The slope of the access aisle is not compliant.
Finding 2.40 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the access aisle to provide a compliant surface slope.
riority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
$3,800
$0.00
Record Number 29206
Parking Off Madison Street
Accessible Space
The access aisle does not contain the wording "No Parking"
painted in white letters within the access aisle.
Finding None Found
CA 11B-502.3.3
aint the words "NO PARKING' a compliant height within the
:cess aisle.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$250
$0.00
Record Number 29204
Parking Off Madison Street
Accessible Space
The access aisle markings are faded, damaged, or otherwise not
viewable.
Finding None Found
CA 11B-502.3
e-stripe the access aisle so as to discourage parking.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 288 of 853
Record Number 29205
Parking Off Madison Street
Accessible Space
The hatched lines are striped a noncompliant distance on center.
Finding Not on 36" center
CA 11B-502.3.3
e-stripe the hatched lines in a contrasting color at a compliant
stance on center.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 29198
Parking Off Madison Street
Accessible Space
The International Symbol of Accessibility (ISA) surface
identification is not centered and aligned with the end of the
space.
Finding Not Visible
ADA 4.6.4, CA 11B-502.6.4
rovide a compliant International Symbol of Accessibility (ISA)
entered and aligned with the end of the accessible parking
Jace.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$220
$0.00
Record Number 29199
Parking Off Madison Street
Accessible Space
The surface identification does not contrast from the parking
space surface.
Finding See Above
Code Not White on Blue
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
Priority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 289 of 853
Record Number 29200
rovide compliant surface identification at the accessible parking
Jace.
$220
$0.00
Parking Off Madison Street
Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 27.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
Record Number 29197
Parking Off Madison Street
Accessible Space
ISA surface identification is faded and not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.6.4
'Repaint the ISA surface identification in the parking space.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$117
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29149
Path Of Travel From The Accessible Space
Path Of Travel From The Accessible Space
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
rovide detectable warnings.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$19G
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 290 of 853
Record Number 29306
,ovide detectable warnings.
$190
$0.00
Path Of Travel From The Public Right Of Way Off Madison
Street
Path Of Travel From The Public Right Of Way Off Madison
Street
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
Record Number 29307
Path Of Travel From The Public Right Of Way Off Madison
Street
Path Of Travel From The Public Right Of Way Off Madison
Street
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
Provide a compliant crosswalk.
riority Three
.esolution Not Set
rogress Not_Started
.ssignment Not Set
$1,100
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29061
Captains Barrack
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 291 of 853
Record Number 29066
Door Between Bay And Hallway Next To Captains Barrack
The height of the threshold at the entrance door is greater than
allowed.
Finding 4.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 29064
Door Between Bay And Hallway Next To Captains Barrack
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 29065
Door Between Bay And Hallway Next To Captains Barrack
Push / Pull
Door hardware is not mounted at the correct height.
Finding 50.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
Mount the door hardware at the recommended height.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 292 of 853
Record Number 29087
Unisex Restroom Next To Kitchen
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 29137
Unisex Restroom Next To Captains Office
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 20.50 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance for the door.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,921
$0.00
Record Number 29136
Unisex Restroom Next To Captains Office
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 293 of 853
Record Number 29269
Captains Office
Lever
The door opening force for this door is greater than allowed.
Finding 13.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 29354
Main Entrance Next To Reception
Pull Side
There is no level landing at this door.
Finding 4.70 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,500
$0.00
Record Number 29353
Main Entrance Next To Reception
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 294 of 853
Record Number 29164
Main Entrance Next To Reception
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 29266
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29454
Unisex Restroom Next To Kitchen
The approach is to the latch side of the compartment door,
clearance between the door side of the compartment and any
obstruction does not meet the minimum required clearance.
Finding 47.87 inches
Code At least 48.00 inches
ADA 4.17.3, CA 11B-604.8.1.2, CA 11B-404.2
"rovide clearance between the door side of the compartment
-id any obstruction that meets the minimum required
earance.
Priority Five
esolution Not Set
rogress Not_Started
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 295 of 853
Record Number 29467
Unisex Restroom Next To Kitchen
The coat hook is not mounted at the correct height.
Finding 68.25 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Two
esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 29465
Unisex Restroom Next To Kitchen
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 29466
Unisex Restroom Next To Kitchen
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Adjust the inside handle so that it is located near the latch.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$129
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 296 of 853
Record Number 29463
Unisex Restroom Next To Kitchen
The height of the side grab bar is not at the correct height.
Finding 34.00 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$500
$0.00
Record Number 29464
Unisex Restroom Next To Kitchen
The grab bar on the rear wall is not at the correct height.
Finding 34.00 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$231
$0.00
Record Number 29460
Unisex Restroom Next To Kitchen
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 0.12 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 297 of 853
Record Number 29461
Unisex Restroom Next To Kitchen
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 29462
Unisex Restroom Next To Kitchen
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 21.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Five
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 29455
Unisex Restroom Next To Kitchen
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 20.00 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
riority Five
esolution Not Set
'rogress Not_Started
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 298 of 853
Record Number 29457
Unisex Restroom Next To Kitchen
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
$127
$0.00
Record Number 29458
Unisex Restroom Next To Kitchen
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Five
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
$2,500
$0.00
Record Number 29459
Unisex Restroom Next To Kitchen
There is less than the required minimum space in front of the
toilet.
Finding 43.75 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
'Treate the required minimum clear space in front of the toilet.
Priority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 299 of 853
Record Number 29498
Unisex Restroom Next To Captains Office
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 50.75 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
°riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,707
$0.00
Record Number 29506
Unisex Restroom Next To Captains Office
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 55.00 inches
Code Up to 12.00 inches
rovide feminine products disposal at the required distance
om front of the toilet.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Record Number 29505
Unisex Restroom Next To Captains Office
The coat hook is not mounted at the correct height.
Finding 53.00 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 300 of 853
Record Number 29504
Unisex Restroom Next To Captains Office
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 0.12 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
priority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$250
$0.00
Record Number 29502
Unisex Restroom Next To Captains Office
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 29503
Unisex Restroom Next To Captains Office
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 23.50 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 301 of 853
Record Number 29499
Unisex Restroom Next To Captains Office
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.00 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 29501
Unisex Restroom Next To Captains Office
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 33.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 29276
Unisex Restroom Next To Kitchen
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$804
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 302 of 853
Record Number 29278
Unisex Restroom Next To Kitchen
The height of the urinal rim in the restroom is not compliant.
Finding 17.50 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
)wer the urinal designated to be accessible in the restroom so
iat the rim height is compliant.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,397
$0.00
Record Number 29279
Unisex Restroom Next To Kitchen
The height of the urinal flush control in the restroom is greater
than the required maximum height.
Finding 43.25 inches
Code At least 44.00 inches
ADA 4.18.4, CA 11B-605.4
)wer the flush control valve on the urinal to a height not
reater than the required maximum height.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$227
$0.00
Record Number 29280
Unisex Restroom Next To Kitchen
The urinal does not meet the requirement for the minimum
projection from the back wall to the front of the urinal rim.
Finding 13.00 inches
Code At least 14.00 inches
ADA 4.18.2, CA 11B-605.2
(stall a urinal that meets the minimum projection
?quirements.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$951
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 303 of 853
Record Number 29283
Unisex Restroom Next To Kitchen
The width between urinal shields in the restroom is less than
required.
Finding 28.50 inches
Code At least 30.00 inches
ADA 4.18.3
odify or replace the urinal shields in the restroom to provide
le required shield -width clearance.
Priority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$230
$0.00
Record Number 29281
Unisex Restroom Next To Kitchen
There is less than the required clear floor space provided in front
of the urinal in the restroom to allow an accessible forward
approach.
Finding 28.50 inches
Code At least 30.00 inches
ADA 4.18.3, CA 11B-605.3, CA 11B-305.3
rovide the required minimum clear floor space in front of the
rinal designated to be accessible in the restroom, for a forward
Dproach.
riority Five
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
$1,707
$0.00
Record Number 29282
Unisex Restroom Next To Kitchen
The urinal center line is not compliant.
Finding 14.12 inches
Code At least 15.00 inches
ADA 4.18.2, CA 11B-605.3
Provide a compliant urinal with recommended values.
Priority Five
.esolution Not Set
rogress Not_Started
Assignment Not Set
$2,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 304 of 853
Record Number 29277
Unisex Restroom Next To Kitchen
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 29284
Unisex Restroom Next To Kitchen
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
riority Three
.esolution Not Set
'regress Not_Started
.ssignment Not Set
$158
$0.00
Record Number 29285
Unisex Restroom Next To Kitchen
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 305 of 853
Record Number 29509
Unisex Restroom Next To Captains Office
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 32.50 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$14,000
$0.00
Record Number 29511
Unisex Restroom Next To Captains Office
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 29513
Unisex Restroom Next To Captains Office
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 306 of 853
Record Number 29512
Unisex Restroom Next To Captains Office
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$158
$0.00
Record Number 29510
Unisex Restroom Next To Captains Office
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29351
Drinking Fountain In Reception Area
There is less than the required minimum knee clearance height
Finding 23.00 inches
Code At least 27.00 inches
ADA 4.15.5, CA 11B-602.2, CA 11B-306
"rovide a fountain with the required knee and toe clearances.
riority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 307 of 853
Record Number 29352
Drinking Fountain In Reception Area
The drinking fountain is not set entirely in an alcove.
Finding None Found
CA 11B-602.9
rovide compliant wing walls or barrier at the drinking fountain.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
$640
$0.00
Record Number 29350
Drinking Fountain In Reception Area
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
riority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,500
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29343
Visual Alarms
There are no visual warning devices at the facility.
Finding None Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
Tnstall visual warning devices integrated with the facility's alarm
istem in all common areas.
Priority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$2,200
$0.00
Accessible Showers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 308 of 853
Record Number 29311
Unisex Restroom Next To Captains Office
There are not enough accessible showers with respect to the total
number of showers available.
Finding None Found
Code At least 1.00 showers
ADA 4.21.2, CA 11B-213.3.6
rovide the required amount of compliant accessible showers.
riority Six
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$4,500
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29059
Main Entrance Next To Reception
Door Bell - Other
The highest point of operation for the element is not compliant.
Finding 51.50 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
Make sure that the highest point of operation is within the
recommended value.
riority Three
esolution Not Set
'rogress Not_Started
assignment Not Set
$50
$0.00
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29189
Benches
There are not enough accessible benches at the location with
respect to the number of benches available.
Finding None Found
Code At least 1.00 benches
ADA 5.8, ADA A4.2.6
rovide compliant accessible benches at the location.
riority Four
.esolution Not Set
rogress Not_Started
.,ssignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 309 of 853
Record Number 29190
Benches
The bench height is not compliant.
Finding 15.75 inches
Code 17.00 - 19.00 inches
ADA 5.8, ADA A4.2.6
djust the bench height to recommended value.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
$800
$0.00
Record Number 29191
Benches
The bench back rest height is not compliant.
Finding 17.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
Hdjust the bench back rest height to recommended value.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 310 of 853
Fire Station #93
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46485
Parking
Parking Lot Warning Sign
The point of contact and telephone number for reclaiming towed
vehicles have been left blank.
Finding Sign not Filled
CA 11B-502.8.2
II in the blank spaces with the point of contact and telephone
umber for reclaiming towed vehicles.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 46481
Parking
Accessible Space Next To Main Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
lternational Symbol of Accessibility.
riority Not Set
esolution Not Set
rogress Not Set
.-ssignment Not Set
$300
$0.00
Record Number 46482
Parking
Accessible Space Next To Main Entrance
The access aisle does not meet the minimum required width.
Finding 92.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
Re -stripe the access aisle.
riority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 311 of 853
Record Number 46483
Parking
Accessible Space Next To BBQ Area
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$300
$0.00
Record Number 46484
Parking
Accessible Space Next To BBQ Area
The access aisle does not meet the minimum required width.
Finding 92.50 inches
Code At least 96.00 inches
ADA 4.1.2(5)
e-stripe the access aisle.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46487
Path Of Travel From The Public Right Of Way Off Adams
Street
Change In Level Next To Main Entrance
There is a change in elevation greater than recommended value.
Finding 0.75 inches
Code Up to 0.25 inches
ADA 4.3.8, CA 11B-303, CA 11B-403.4
rnsure that the change in elevation is within the recommended
Slue.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$150
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 312 of 853
Record Number 46488
(stall side extensions, modify, relocate, or lower the item so
'at it is not a protruding object into the circulation route.
$640
$0.00
Path Of Travel In Kitchen
Counter
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 6.50 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46454
Office
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 53.25 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 46453
Office
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'adjust the closer on the door to meet the door opening force
requirements.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 313 of 853
Record Number 46459
Unisex Restroom Next To Office
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 11.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 46458
Unisex Restroom Next To Office
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$25
$0.00
Record Number 46461
Door Between Reception & Hallway Break Area
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 18.25 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide the recommended clear floor space on the push side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
_.ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 314 of 853
Record Number 46460
Door Between Reception & Hallway Break Area
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 46462
Main Entrance Next To Reception
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46490
Directional Signage From The Public Right Of Way
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
Install directional signage to each accessible element or room.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 315 of 853
Record Number 46452
Copy Room/Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 46457
Main Entrance Next To Reception
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 46463
Door Between Reception & Bay
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 316 of 853
Record Number 46486
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46451
Unisex Restroom Next To Office
The restroom is not accessible and cannot be easily altered.
There is not sufficient clear floor space to accommodate an
individual in a wheelchair.
Finding Not Accessible
ADA 4.23
Consult a design professional to modify the restroom for access
)mpliance.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 46464
Unisex Restroom Next To Office
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 317 of 853
Record Number 46467
Unisex Restroom Next To Office
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
rovide a compliant toilet paper dispenser.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$230
$0.00
Record Number 46465
Unisex Restroom Next To Office
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46469
Visual Alarms
There are some visual warning devices, though visual warning
devices are not located throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
Tnstall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, classrooms and
2neral use rooms, accessible restrooms and other accessible
)oms.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,200
$0.00
Accessible Showers
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 318 of 853
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46468
Shower In Right Unisex Restroom Next To Kitchen
There are not enough accessible showers with respect to the total
number of showers available.
Finding None Found
Code At least 1.00 showers
ADA 4.21.2, CA 11B-213.3.6
Provide the required amount of compliant accessible showers.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$4,500
$0.00
Record Number 46470
Shower In Left Unisex Restroom Next To Kitchen
There are not enough accessible showers with respect to the total
number of showers available.
Finding None Found
Code At least 1.00 showers
ADA 4.21.2, CA 11B-213.3.6
Provide the required amount of compliant accessible showers.
4riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$4,500
$0.00
Record Number 46471
Shower In Unisex Restroom Next To Cheifs Bedroom
The opening width of the shower compartment is less than
required.
Finding 38.00 inches
Code At least 42.00 inches
ADA 4.21.2, CA 11B-608.2
Increase the shower compartment opening to the correct
idth.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 319 of 853
Record Number 46477
Shower In Unisex Restroom Next To Cheifs Bedroom
The soap dish is not mounted at a compliant height.
Finding 57.50 inches
Code 15.00 - 40.00 inches
CA 11B-608.10
elocated the soap dish on the same wall as the water controls
a compliant height.
riority Not Set
esolution Not Set
'regress Not Set
.ssignment Not Set
$277
$0.00
Record Number 46475
Shower In Unisex Restroom Next To Cheifs Bedroom
Shower seat length is not compliant.
Finding Not Accessible
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant seat that extends the full length of the
lower.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,068
$0.00
Record Number 46476
Shower In Unisex Restroom Next To Cheifs Bedroom
The folding seat in the accessible shower is not mounted at a
compliant height above the finished floor.
Finding 19.25 inches
Code 18.00 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
emount the folding seat to a compliant height above the
nished floor.
riority Not Set
esolution Not Set
'regress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 320 of 853
Record Number 46474
Shower In Unisex Restroom Next To Cheifs Bedroom
The distance between the grab bar and the wall it is mounted on
is not compliant.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.21.4, CA 11B-609.3, CA 11B-608.3
emount the grab bar in the accessible shower to provide a
)mpliant distance between the grab bar and the wall they are
counted on.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$78
$0.00
Record Number 46478
Shower In Unisex Restroom Next To Cheifs Bedroom
The operational force required to operate the water valve is not
compliant
Finding Not Accessible
ADA 4.21.5, CA 11B-608.5, CA 11B-309.4
Provide an accessible water control device that can be operated
ith one hand and a compliant pounds of force to operate.
riority Not Set
.esolution Not Set
'rogress Not Set
_,ssignment Not Set
$554
$0.00
Record Number 46479
Shower In Unisex Restroom Next To Cheifs Bedroom
The water valve distance from seat wall is not compliant.
Finding 27.50 inches
Code 18.00 - 24.00 inches
ADA 4.21.5, CA 11B-608.5
Provide a compliant water valve.
'riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 321 of 853
Record Number 46480
Shower In Unisex Restroom Next To Cheifs Bedroom
The water control valve is not mounted at a compliant height.
Finding 47.00 inches
Code Up to 40.00 inches
ADA 4.21.5, CA 11B-608.5
emount the water control valve.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$554
$0.00
Record Number 46472
Shower In Unisex Restroom Next To Cheifs Bedroom
The hand-held sprayer unit is not mounted at the required height
above the finished floor.
Finding 65.00 inches
Code Up to 48.00 inches
ADA 4.21, ADA 4.21.6, CA 11B-608.5
rovide a compliant hand-held sprayer unit with a hose.
riority Not Set
esolution Not Set
rogress Not Set
,assignment Not Set
$385
$0.00
Record Number 46473
Shower In Unisex Restroom Next To Cheifs Bedroom
The controls on the showers hand held mount are not accessible.
ADA 4.21
rovide accessible controls on the hand held mount.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$540
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 322 of 853
Record Number 46489
Shower In Unisex Restroom Next To Weight Room
There are not enough accessible showers with respect to the total
number of showers available.
Finding None Found
Code At least 1.00 showers
ADA 4.21.2, CA 11B-213.3.6
rovide the required amount of compliant accessible showers.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$4,500
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46455
Reception
Vending Machine
The forward reach height of the controls on the vending machine
is greater than the allowed maximum height.
Finding 55.87 inches
Code Up to 48.00 inches
ADA 4.2.5
Contact the owner of the vending machines to obtain accessible
vending machines.
riority Not Set
esolution Not Set
'rogress Not Set
ssignment Not Set
$0.00
Record Number 46456
Reception
Vending Machine
The controls of the vending machine require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.2.5
Replace controls of vending machine with those that allow
aeration with one hand and does not require tight grasping,
inching, or twisting of the wrist.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$550
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 323 of 853
La Quinta Library
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43481
Parking Lot
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Record Number 43482
Parking Lot
Left Accessible Space At The Main Entrance
The accessible parking space does not meet the minimum
requirements for width.
Finding 105.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43483
Parking Lot
Left Accessible Space At The Main Entrance
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
)stall a wheel stop at the head of the accessible parking space.
°riority Three
esolution Not Set
rogress Not_Started
ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 324 of 853
Record Number 43484
Parking Lot
Left Accessible Space At The Main Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43486
Parking Lot
Left Accessible Space At The Main Entrance
The designated accessible parking space does not provide
accessible signage at the head of the space.
Finding None Found
ADA 4.6.4
rovide compliant sigange at the accessible space.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Record Number 43487
Parking Lot
Left Accessible Space At The Main Entrance
There is no additional signage marked "van accessible" at the van
accessible parking space.
Finding None Found
ADA 4.6.4
Van accessible parking spaces shall provide additional signage
'at states "van accessible" .
Priority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 325 of 853
Record Number 43485
Parking Lot
Left Accessible Space At The Main Entrance
The surface identification at the designated accessible parking
space is not compliant.
Finding 51.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43488
Parking Lot
Left Accessible Space At The Main Entrance
The access aisle does not meet the minimum required width.
Finding 95.50 inches
Code At least 96.00 inches
ADA 4.1.2(5)
De -stripe the access aisle.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43489
Parking Lot
Center Accessible Space At The Main Entrance
The accessible parking space does not meet the minimum
requirements for width.
Finding 104.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
De -stripe the accessible parking space.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 326 of 853
Record Number 43490
Parking Lot
Center Accessible Space At The Main Entrance
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
stall a wheel stop at the head of the accessible parking space.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43491
Parking Lot
Center Accessible Space At The Main Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
-'rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
Priority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Record Number 43493
Parking Lot
Center Accessible Space At The Main Entrance
The designated accessible parking space does not provide
accessible signage at the head of the space.
Finding None Found
ADA 4.6.4
rovide compliant sigange at the accessible space.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 327 of 853
Record Number 43494
Parking Lot
Center Accessible Space At The Main Entrance
There is no additional signage marked "van accessible" at the van
accessible parking space.
Finding None Found
ADA 4.6.4
an accessible parking spaces shall provide additional signage
'at states "van accessible" .
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43492
Parking Lot
Center Accessible Space At The Main Entrance
The surface identification at the designated accessible parking
space is not compliant.
Finding 50.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
°rovide compliant surface identification at the accessible parking
Dace.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43495
Parking Lot
Right Accessible Space At The Main Entrance
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
Install a wheel stop at the head of the accessible parking space.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 328 of 853
Record Number 43496
Parking Lot
Right Accessible Space At The Main Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43497
Parking Lot
Right Accessible Space At The Main Entrance
The surface identification at the designated accessible parking
space is not compliant.
Finding 50.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
tiority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43498
Parking Lot
Right Accessible Space At The Main Entrance
The designated accessible parking space does not provide
accessible signage at the head of the space.
Finding None Found
ADA 4.6.4
rovide compliant sigange at the accessible space.
tiority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 329 of 853
Record Number 43442
Curb Ramp From Left Access Aisle
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Five
esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$248
$0.00
Record Number 43443
Curb Ramp From Left Access Aisle
The slope of the curb ramp left side flare is greater than allowed.
Finding 12.40 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
rovide curb ramp side flares with a compliant slope.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43449
Curb Ramp From Right Access Aisle
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
Provide compliant detectable warnings to surface.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 330 of 853
Record Number 43450
Curb Ramp From Right Access Aisle
The running slope is greater than allowed.
Finding 8.80 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
rovide a compliant curb ramp.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43451
Curb Ramp From Right Access Aisle
The slope of the curb ramp left side flare is greater than allowed.
Finding 12.60 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
rovide curb ramp side flares with a compliant slope.
riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43438
Path Of Travel Near Chamber Entrance
Vegetation
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 27.00 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
Tnstall side extensions, modify, relocate, or lower the item so
iat it is not a protruding object into the circulation route.
riority Five
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$640
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 331 of 853
Record Number 43447
Path Of Travel From Parking Lot
Crosswalk
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
rovide detectable warnings.
riority Five
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$190
$0.00
Record Number 43448
Path Of Travel From Parking Lot
Crosswalk
Crosswalk is not striped.
Finding None Found
ADA 4.29
Crosswalk should be striped.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Record Number 43503
Path Of Travel From Public Right Of Way To Chamber Of
Commerce
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 8.10 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
riority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$3,600
$0.00
Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 332 of 853
Record Number 43440
rovide an intermediate landing so the ramp run does not
Kceede its maximum distance allowed for its slope (rise).
06/30/2013
$3,168
$0.00
Ramp From Public Right Of Way To Front Entrance
Run 1
The length of the ramp exceeds the maximum distance allowed for
its slope (rise).
Finding 492.00 inches
ADA 4.8.2
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
Record Number 43441
Ramp From Public Right Of Way To Front Entrance
Run 1 Top Landing
The slope of the landing is greater than required.
Finding 2.90 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-405.7.1
"1odify the landing to create a slope in any direction not
Kceeding the required maximum value.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,872
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43587
Chamber Of Commerce Break Room
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 8.25 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$2,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 333 of 853
Record Number 43597
Door Between Library & Chamber Of Commerce
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 7.50 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$2,000
$0.00
Record Number 43596
Door Between Library & Chamber Of Commerce
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
i equirements.
riority Two
esolution Corrected
'rogress Completed
assignment Not Set
06/30/2013
$25
$0.00
Record Number 43614
Cubicle Offices
The clear opening width of the door is less than required.
Finding 30.25 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
Widen the door opening and install a door that provides at least
the minimum clear width with the door open 90 degrees.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 334 of 853
Record Number 43615
Cubicle Offices
Lever
Door hardware is not mounted at the correct height.
Finding 44.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
tiority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$280
$0.00
Record Number 43446
Outside Mens Restroom
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 49.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the pull side of
le door.
tiority Four
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$2,921
$0.00
Record Number 43445
Outside Mens Restroom
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 335 of 853
Record Number 43444
Outside Mens Restroom
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
tiority Four
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$400
$0.00
Record Number 43480
North Entrance
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"lodify or replace the threshold to provide the recommended
eight.
tiority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$436
$0.00
Record Number 43479
North Entrance
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
tiority Two
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 336 of 853
Record Number 43502
Outside Womens Restroom
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 50.12 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the pull side of
le door.
riority Four
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43501
Outside Womens Restroom
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.87 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"lodify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$436
$0.00
Record Number 43500
Outside Womens Restroom
Push / Pull
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Install a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Corrected
'rogress Completed
_.ssignment Not Set
06/30/2013
07/25/2014
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 337 of 853
Record Number 43595
Chamber Of Commerce Entrance
Pull Side
There is no level landing at this door.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
tiority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43594
Chamber Of Commerce Entrance
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
tiority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$25
$0.00
Record Number 43606
Gate To Chamber Of Commerce Entrance
Pull Side
There is no level landing at this door.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
ovide a level landing.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 338 of 853
Record Number 43605
Gate To Chamber Of Commerce Entrance
None
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$400
$0.00
Record Number 43617
Gate To Garden
Pull Side
There is no level landing at this door.
Finding 7.10 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
°rovide a level landing.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43616
Gate To Garden
None
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Install a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
esolution Corrected
rogress Completed
_.ssignment Not Set
06/30/2013
07/25/2014
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 339 of 853
Record Number 43546
Storytime Room
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$25
$0.00
Record Number 43547
Storytime Room
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$50
$0.00
Record Number 43549
Mens Restroom Near North Entrance
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 340 of 853
Record Number 43548
Mens Restroom Near North Entrance
Push / Pull
Door hardware is not mounted at the correct height.
Finding 49.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Corrected
'rogress Completed
assignment Not Set
06/30/2013
07/25/2014
$280
$0.00
Record Number 43551
Hallway Conference Room Door
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$25
$0.00
Record Number 43552
Hallway Conference Room Door
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 341 of 853
Record Number 43553
Womens Restroom Near North Entrance
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$25
$0.00
Record Number 43554
Womens Restroom Near North Entrance
Push / Pull
Door hardware is not mounted at the correct height.
Finding 46.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$280
$0.00
Record Number 43569
Room 110
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 45.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 342 of 853
Record Number 43567
Room 110
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43568
Room 110
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43589
Young Adult Room
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 8.00 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$2,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 343 of 853
Record Number 43588
Young Adult Room
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2025
$25
$0.00
Record Number 43598
Door From Library To Conference Room
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 8.00 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$2,000
$0.00
Record Number 43608
Directors Office
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 59.37 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
Provide the recommended clear floor space on the pull side of
the door.
riority Five
.esolution Not Set
'rogress Not_Started
ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 344 of 853
Record Number 43632
Bookstore
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
07/25/2014
$25
$0.00
Record Number 43633
Literacy Office & Tutoring Room 1
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 8.50 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$2,000
$0.00
Record Number 43634
Door To Garden
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
requirements.
riority Two
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 345 of 853
Record Number
Door To Garden
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
43635
emove the door stop.
riority Two
.esolution Corrected
rogress Completed
assignment Not Set
06/30/2013
$50
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43583
Reception Counter
The height of the counter or desk does not comply with height
requirements.
Finding 48.00 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
provide a portion of counter at the compliant height.
riority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$3,500
$0.00
Record Number 43584
Reception Counter
The counter is a protruding object.
Finding See Above
ADA 4.32.4, ADA 7.2
Adjust the counter so that it is no longer a protruding object.
riority Four
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$450
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 346 of 853
Record Number 43639
Door Between Library & Chamber Of Commerce
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43640
Cubicle Offices
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43641
Chamber Of Commerce Break Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 347 of 853
Record Number 43499
Directional Signage From Public Right Of Way
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
07/25/2014
07/25/2014
$158
$0.00
Record Number 43504
North Entrance
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43586
Chamber Of Commerce Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
install accessible room signage.
°riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 348 of 853
Record Number 43604
South Main Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Three
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43534
Room 110
The accessible element/identification signage attached to the wall
does not include Braille characters.
Finding None Found
ADA 4.30.4, CA 11B-703.3
(stall accessible signage to include Grade 2 Braille characters.
riority Three
.esolution Corrected
rogress Completed
,assignment Not Set
06/30/2013
$50
$0.00
Record Number 43536
Room 110
The accessible element/identification signage attached to the wall
does not include raised lettering or numbering.
Finding None Found
ADA 4.30.4, CA 11B-703.2.1
(stall accessible signage that includes raised UPPERCASE
tters and/or numbers between 5/8 inch and 2 inches in height
riority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 349 of 853
Record Number 43535
Room 110
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 62.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43533
Room 110
Braille is not located below the raised letters.
Finding None Found
ADA 4.4.2, CA 11B-703.3.2
Make sure that braille is located below the raised letters.
riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43570
Emergency Exits
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
Install compliant room identification signage.
riority Three
esolution Corrected
'rogress Completed
.ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 350 of 853
Record Number 43576
Storytime Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43600
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43601
Door To Garden
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
°riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 351 of 853
Record Number 43609
Conference Room, Young Adult Room, Bookstore, Tutoring
Room & Literacy Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
.esolution Corrected
rogress Completed
_,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43613
Directional Signage To Restroom Near Childrens Area
There is signage suspended or projected overhead. The size of the
lettering is less than required or cannot be viewed at a practical
distance.
Finding 2.25 inches
Code At least 3.00 inches
ADA 4.30.3, CA 11B-703.5.5, CA 11B-703.2.5
(stall accessible signage with lettering sized according to
ewing distance.
riority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43452
Outside Womens Restroom
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
rovide a compliant door lock for the door that does not require
3ht grasping, pinching, or twisting of the wrist to operate.
riority Four
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 352 of 853
Record Number 43454
Outside Womens Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.00 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
iron height.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43455
Outside Womens Restroom
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 16.62 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
°eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Six
.esolution Not Set
rogress Not_Started
assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43457
Outside Womens Restroom
The signage is not mounted at the required height.
Finding 58.50 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
riority Seven
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 353 of 853
Record Number 43456
Outside Womens Restroom
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Two
esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43453
Outside Womens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43458
Outside Mens Restroom
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
Provide a compliant door lock for the door that does not require
ght grasping, pinching, or twisting of the wrist to operate.
riority Four
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 354 of 853
Record Number 43461
Outside Mens Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 27.12 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
iron height.
tiority Six
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$2,500
$0.00
Record Number 43462
Outside Mens Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Tnsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Two
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 43463
Outside Mens Restroom
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 355 of 853
Record Number 43464
Outside Mens Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
.esolution Corrected
rogress Completed
_,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43459
Outside Mens Restroom
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43460
Outside Mens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Four
.esolution Corrected
'rogress Completed
_assignment Not Set
06/30/2013
07/25/2014
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 356 of 853
Record Number 43469
Outside Mens Restroom
The door to the compartment designated to be accessible in the
restroom does not have appropriate accessible hardware.
Finding Not Accessible
ADA 4.13.9, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7, CA 11B-6
04.8.1.2
(stall accessible hardware on the compartment door that does
Dt require tight grasping, pinching, or twisting of the wrist.
priority Three
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
$289
$0.00
Record Number 43468
Outside Mens Restroom
The height of the side grab bar is not at the correct height.
Finding 32.75 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
Remount the grab bar so it is at the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43465
Outside Mens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.62 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 357 of 853
Record Number 43467
Outside Mens Restroom
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
tiority Six
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$127
$0.00
Record Number 43471
Outside Womens Restroom
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Four
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$277
$0.00
Record Number 43470
Outside Womens Restroom
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Four
.esolution Corrected
rogress Completed
.assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 358 of 853
Record Number 43478
Outside Womens Restroom
The door to the compartment designated to be accessible in the
restroom does not have appropriate accessible hardware.
Finding Not Accessible
ADA 4.13.9, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7, CA 11B-6
04.8.1.2
(stall accessible hardware on the compartment door that does
Dt require tight grasping, pinching, or twisting of the wrist.
°riority Four
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
$289
$0.00
Record Number 43476
Outside Womens Restroom
The height of the side grab bar is not at the correct height.
Finding 32.87 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
Remount the grab bar so it is at the correct height.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43477
Outside Womens Restroom
The grab bar on the rear wall is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 359 of 853
Record Number 43473
Outside Womens Restroom
The height of the toilet seat is not at the required height.
Finding 16.25 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
tiority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,707
$0.00
Record Number 43472
Outside Womens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.25 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43475
Outside Womens Restroom
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
tiority Six
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$127
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 360 of 853
Record Number 43516
Mens Restroom Near North Entrance
The coat hook is not mounted at the correct height.
Finding 49.00 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$50
$0.00
Record Number 43513
Mens Restroom Near North Entrance
The compartment door hardware is not at a compliant height.
Finding 45.25 inches
Code Up to 44.00 inches
ADA 4.17.5, ADA 404.2.7, CA 11B-404.2.7, CA 11B-604.8.1.2
emove and relocate the door hardware.
riority Four
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 43512
Mens Restroom Near North Entrance
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$269
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 361 of 853
Record Number 43514
Mens Restroom Near North Entrance
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Four
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43515
Mens Restroom Near North Entrance
There is less than the required latch side clearance on the pull side
of the door.
Finding 4.25 inches
Code At least 18.00 inches
ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404
rovide required latch side clearance on the pull side of the
Dor.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,200
$0.00
Record Number 43509
Mens Restroom Near North Entrance
The height of the side grab bar is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
°riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 362 of 853
Record Number 43508
Mens Restroom Near North Entrance
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43510
Mens Restroom Near North Entrance
The distance from the side wall to the rear grab bar is greater
than allowed.
Finding 6.25 inches
Code Up to 6.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2
emount the rear grab bar at a compliant location.
riority Three
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$78
$0.00
Record Number 43511
Mens Restroom Near North Entrance
The grab bar on the rear wall is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 363 of 853
Record Number 43507
Mens Restroom Near North Entrance
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.12 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43505
Mens Restroom Near North Entrance
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 20.25 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43517
Mens Restroom Near North Entrance
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
stance from the front edge of the toilet seat.
tiority Three
.esolution Corrected
'rogress Completed
.,ssignment Not Set
06/30/2013
$78
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 364 of 853
Record Number 43520
Mens Restroom Near North Entrance
The height of the urinal rim in the restroom is not compliant.
Finding 17.25 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
)wer the urinal designated to be accessible in the restroom so
'at the rim height is compliant.
tiority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,397
$0.00
Record Number 43522
Mens Restroom Near North Entrance
The signage is not mounted at the required height.
Finding 59.50 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Dst compliant signage at the restroom.
riority Seven
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43523
Mens Restroom Near North Entrance
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
tiority Three
.esolution Corrected
'rogress Completed
.,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 365 of 853
Record Number 43518
Mens Restroom Near North Entrance
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
tiority Two
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43519
Mens Restroom Near North Entrance
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Two
.esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 43521
Mens Restroom Near North Entrance
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 58.62 inches
Code 60.00 inches
CA 11B-703.7.2.6
Post gender use signage on the center of the door at the
required height.
riority Seven
.esolution Corrected
rogress Completed
.ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 366 of 853
Record Number 43532
Womens Restroom Near North Entrance
The coat hook is not mounted at the correct height.
Finding 48.50 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$50
$0.00
Record Number 43529
Womens Restroom Near North Entrance
The compartment door hardware is not at a compliant height.
Finding 45.00 inches
Code Up to 44.00 inches
ADA 4.17.5, ADA 404.2.7, CA 11B-404.2.7, CA 11B-604.8.1.2
emove and relocate the door hardware.
riority Six
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 43528
Womens Restroom Near North Entrance
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Six
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$269
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 367 of 853
Record Number 43530
Womens Restroom Near North Entrance
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Six
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43531
Womens Restroom Near North Entrance
There is less than the required latch side clearance on the pull side
of the door.
Finding 4.50 inches
Code At least 18.00 inches
ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404
rovide required latch side clearance on the pull side of the
Dor.
riority Six
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$2,200
$0.00
Record Number 43527
Womens Restroom Near North Entrance
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
riority Seven
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 368 of 853
Record Number 43524
Womens Restroom Near North Entrance
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.87 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43526
Womens Restroom Near North Entrance
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43542
Womens Restroom Near Childrens Area
Lavatory
The height of the counter surface is greater than allowed.
Finding 35.62 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Five
.esolution Corrected
'rogress Completed
.ssignment Not Set
06/30/2013
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 369 of 853
Record Number 43541
Womens Restroom Near Childrens Area
Lavatory
The faucet controls on the lavatory require tight grasping,
pinching, or twisting of the wrist and are not accessible.
Finding Not Accessible
ADA 4.19.5, ADA 309.4, CA 11B-309.4, CA 11B-213, CA 11B-606
(stall accessible faucet controls on the lavatory.
riority Six
esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$392
$0.00
Record Number 43544
Womens Restroom Near Childrens Area
The signage is not mounted at the required height.
Finding 61.12 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
riority Seven
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43545
Womens Restroom Near Childrens Area
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
esolution Corrected
'rogress Completed
.,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 370 of 853
Record Number 43543
Womens Restroom Near Childrens Area
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 61.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Seven
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43558
Womens Restroom Near Childrens Area
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
°rovide a grab bar that has a compliant gripping surface meets
I other requirements.
riority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$250
$0.00
Record Number 43559
Womens Restroom Near Childrens Area
The height of the side grab bar is not at the correct height.
Finding 33.12 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
^emount the grab bar so it is at the correct height.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 371 of 853
Record Number 43560
Womens Restroom Near Childrens Area
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
(stance from the front edge of the toilet seat.
riority Three
esolution Corrected
rogress Completed
.ssignment Not Set
06/30/2013
07/25/2014
$78
$0.00
Record Number 43555
Womens Restroom Near Childrens Area
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43557
Womens Restroom Near Childrens Area
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 31.62 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 372 of 853
Record Number 43564
Mens Restroom Near Childrens Area
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 1.37 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43565
Mens Restroom Near Childrens Area
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.75 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43566
Mens Restroom Near Childrens Area
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
stance from the front edge of the toilet seat.
tiority Three
.esolution Corrected
'rogress Completed
.,ssignment Not Set
06/30/2013
07/25/2014
$78
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 373 of 853
Record Number 43561
Mens Restroom Near Childrens Area
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.62 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43563
Mens Restroom Near Childrens Area
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 32.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43572
Mens Restroom Near Childrens Area
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 374 of 853
Record Number 43571
Mens Restroom Near Childrens Area
Lavatory
The height of the counter surface is greater than allowed.
Finding 36.00 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
tiority Six
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$1,286
$0.00
Record Number 43573
Mens Restroom Near Childrens Area
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
tiority Seven
.esolution Corrected
'rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43574
Mens Restroom Near Childrens Area
The signage is not mounted at the required height.
Finding 62.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Dst compliant signage at the restroom.
riority Three
.esolution Corrected
rogress Completed
_,ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 375 of 853
Record Number 43575
Mens Restroom Near Childrens Area
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Corrected
rogress Completed
.ssignment Not Set
06/30/2013
07/25/2014
$158
$0.00
Record Number 43579
Womens Restroom Near North Entrance
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 58.50 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43580
Womens Restroom Near North Entrance
Female
The restroom signage is not compliant.
Finding None Found
CA 11B-703.7.2.6.2
rovide compliant restroom signage.
riority Three
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 376 of 853
Record Number 43577
Womens Restroom Near North Entrance
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.62 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,286
$0.00
Record Number 43578
Womens Restroom Near North Entrance
Lavatory
There is not enough toe clearance at the restroom lavatory.
Finding 1.00 inches
Code At least 9.00 inches
ADA 4.19.2
°rovide minimum required toe clearance.
riority Six
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$289
$0.00
Record Number 43581
Womens Restroom Near North Entrance
The signage is not mounted at the required height.
Finding 59.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Tost compliant signage at the restroom.
riority Seven
.esolution Corrected
rogress Completed
_,ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 377 of 853
Record Number 43582
Womens Restroom Near North Entrance
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Corrected
rogress Completed
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43610
Unisex Staff Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$804
$0.00
Record Number 43611
Unisex Staff Restroom
Lavatory
The faucet controls on the lavatory require tight grasping,
pinching, or twisting of the wrist and are not accessible.
Finding Not Accessible
ADA 4.19.5, ADA 309.4, CA 11B-309.4, CA 11B-213, CA 11B-606
(stall accessible faucet controls on the lavatory.
riority Six
.esolution Corrected
rogress Completed
_assignment Not Set
06/30/2013
07/25/2014
$392
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 378 of 853
Record Number 43612
Unisex Staff Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$1,286
$0.00
Record Number 43625
Unisex Staff Restroom
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 46.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
°elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Four
.esolution Corrected
'regress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$277
$0.00
Record Number 43624
Unisex Staff Restroom
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Three
.esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 379 of 853
Record Number 43630
Unisex Staff Restroom
The coat hook is not mounted at the correct height.
Finding 67.37 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Three
esolution Corrected
rogress Completed
Assignment Not Set
06/30/2013
07/25/2014
$50
$0.00
Record Number 43629
Unisex Staff Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.87 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43631
Unisex Staff Restroom
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 12.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Three
esolution Corrected
'rogress Completed
Assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 380 of 853
Record Number 43626
Unisex Staff Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.87 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43628
Unisex Staff Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 31.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Libraries
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43618
Adult Library
The space between book shelves is less than required value.
Finding 39.50 inches
Code At least 44.00 inches
ADA 8.5, CA 11B-403.5.1
(crease the space between shelves to the recommended value.
riority Five
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$2,160
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 381 of 853
Record Number 43638
Childrens Library
The knee clearance height at the table for use primarily by
children is not compliant.
Finding 20.25 inches
Code At least 24.00 inches
ADA 4.32.5(2)
rovide a compliant table for use primarily by children.
riority Five
esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$174
$0.00
Record Number 43637
Childrens Library
The height of the checkout counter is used primarily by children is
not compliant.
Finding 30.37 inches
Code Up to 30.00 inches
ADA 7.2, ADA 8.3, CA 11B-902.4.2
ake sure a portion of the counter is within compliant height
inges to accommodate age group requirements for children.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$545
$0.00
Record Number 43636
Childrens Library
The space between book shelves is less than required value.
Finding 41.25 inches
Code At least 44.00 inches
ADA 8.5, CA 11B-403.5.1
(crease the space between shelves to the recommended value.
°riority Five
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,160
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 382 of 853
Record Number 43607
Visual Alarms
There are some visual warning devices, though visual warning
devices are not located throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, classrooms and
eneral use rooms, accessible restrooms and other accessible
)oms.
riority Six
.esolution Corrected
rogress Completed
,ssignment Not Set
06/30/2013
07/25/2014
$2,200
$0.00
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43619
Chamber Of Commerce Break Room
No visual alarms found at the location.
Finding None Found
ADA 4.27
'rovide visual alarms at the location.
tiority Seven
esolution Not Set
'rogress Not_Started
ssignment Not Set
06/30/2013
07/25/2014
$388
$0.00
Record Number 43620
Chamber Of Commerce Break Room
Sink counter height does not meet the standards.
Finding 35.75 inches
Code Up to 34.00 inches
CA 11B-606.3
^rovide compliant sink.
tiority Six
esolution Not Set
'rogress Not_Started
ssignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 383 of 853
Record Number 43621
Chamber Of Commerce Break Room
The toe kick for the sink in break/conference room is not removed.
Finding Not Removed
CA 11B-606.2, CA 11B-305, CA 11B-306
emove the toe kick for the sink.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$612
$0.00
Record Number 43622
Chamber Of Commerce Break Room
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
ipes under the sink to protect against contact. Make certain
iere are no sharp or abrasive surfaces under the sink.
riority Two
.esolution Not_Corrected
'rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 43623
Chamber Of Commerce Break Room
Microwave
Appliance Reach Height in the break/conference room is not
compliant.
Finding 64.25 inches
Code Up to 48.00 inches
CA 11B-308, CA 11B-309, CA 11B-205
ake sure that the specified appliance reach height is
)mpliant.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 384 of 853
Record Number 43537
Conference Room
The table knee clearance does not meet required standards.
Finding 26.87 inches
Code At least 27.00 inches
CA 11B-902.2, CA 11B-305, CA 11B-306
rovide compliant tables.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43538
Conference Room
The table knee width does not meet required standards.
Finding 29.50 inches
Code At least 30.00 inches
ADA 4.27
rovide compliant tables.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,174
$0.00
Record Number 43539
Conference Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
install an International Symbol of Accessibility at the table.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 385 of 853
Record Number 43540
Conference Room
There is not enough clear floor space at the table.
Finding 29.50 inches
Code At least 30.00 inches
ADA 4.27
rovide compliant clear floor space at the table.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43592
Library Staff Break Room
Sink counter height does not meet the standards.
Finding 36.00 inches
Code Up to 34.00 inches
CA 11B-606.3
rovide compliant sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Record Number 43590
Library Staff Break Room
The table knee depth does not meet required standards.
Finding 6.00 inches
Code At least 19.00 inches
ADA 4.27, CA 11B-306, CA 11B-902
Provide compliant tables.
priority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$2,174
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 386 of 853
Record Number 43591
Library Staff Break Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43593
Library Staff Break Room
Microwave
Appliance Reach Height in the break/conference room is not
compliant.
Finding 68.50 inches
Code Up to 48.00 inches
CA 11B-308, CA 11B-309, CA 11B-205
ake sure that the specified appliance reach height is
)mpliant.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,200
$0.00
Record Number 43602
Young Adult Room
The table knee depth does not meet required standards.
Finding 4.00 inches
Code At least 19.00 inches
ADA 4.27, CA 11B-306, CA 11B-902
rovide compliant tables.
riority Seven
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
06/30/2013
$2,174
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 387 of 853
Record Number 43603
Young Adult Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$158
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43550
Room 110
Sink counter height is not compliant.
Finding 35.75 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
provide compliant sink.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$1,800
$0.00
Lockers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43585
Staff Lockers
No accessible lockers were found.
Finding Not Available
CA 11B-225.2.1, CA 11B-811
rovide a compliant amount of accessible lockers.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 388 of 853
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43439
Library Book Return
Book Return - Other
The highest point of operation for the element is not compliant.
Finding 51.25 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
commended value.
riority Seven
.esolution Not Set
'rogress Not_Started
.assignment Not Set
06/30/2013
$50
$0.00
Record Number 43599
Adult Library
Copy Machine - Other
The highest point of operation for the element is not compliant.
Finding 0.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
Make sure that the highest point of operation is within the
recommended value.
riority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 389 of 853
La Quinta Museum
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43948
Parking At Museum
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$250
$0.00
Record Number 43950
Parking At Museum
Right Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 100.25 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 43951
Parking At Museum
Right Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
riority Seven
.esolution Not Set
rogress Not_Started
assignment Not Set
$3,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 390 of 853
Record Number 43952
Parking At Museum
Right Accessible Space
The accessible parking space does not meet the minimum
requirement for length.
Finding 185.50 inches
Code At least 216.00 inches
CA 11B-502.2
e-stripe the accessible parking space.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 43949
Parking At Museum
Right Accessible Space
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
Re -stripe the existing parking space marked as accessible to
'efine the width of the space.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 43953
Parking At Museum
Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 391 of 853
Record Number 43955
Parking At Museum
Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.50 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$220
$0.00
Record Number 43954
Parking At Museum
Right Accessible Space
ISA surface identification is faded and not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.6.4
°epaint the ISA surface identification in the parking space.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$117
$0.00
Record Number 43956
Parking At Museum
Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 107.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
De -stripe the accessible parking space.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 392 of 853
Record Number 43957
Parking At Museum
Left Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
tiority Seven
esolution Not Set
'regress Not_Started
assignment Not Set
$3,800
$0.00
Record Number 43958
Parking At Museum
Left Accessible Space
The accessible parking space does not meet the minimum
requirement for length.
Finding 188.00 inches
Code At least 216.00 inches
CA 11B-502.2
e-stripe the accessible parking space.
tiority Three
esolution Not Set
'regress Not_Started
,ssignment Not Set
$350
$0.00
Record Number 43959
Parking At Museum
Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 393 of 853
Record Number 43960
Parking At Museum
Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.50 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$220
$0.00
Record Number 43962
Parking At Museum
Left Accessible Space
The slope of the access aisle is not compliant.
Finding 3.00 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
°epave the access aisle to provide a compliant surface slope.
riority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
$3,800
$0.00
Record Number 43963
Parking At Museum
Left Accessible Space
The access aisle markings are faded, damaged, or otherwise not
viewable.
Finding None Found
CA 11B-502.3
De -stripe the access aisle so as to discourage parking.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 394 of 853
Record Number 43964
e-stripe the hatched lines in a contrasting color at a compliant
(stance on center.
$350
$0.00
Parking At Museum
Left Accessible Space
The hatched lines are striped a noncompliant distance on center.
Finding Not on 36" center
CA 11B-502.3.3
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43941
Curb Ramp At The Head Of The Access Aisle
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
provide compliant detectable warnings to surface.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$248
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43927
Path Of Travel At 2nd Floor Balcony
Lights
The vertical clearance height is less than required.
Finding 76.00 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307.4
rovide recommended vertical clearance.
riority Seven
.esolution Not Set
rogress Not_Started
assignment Not Set
$108
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 395 of 853
Record Number 43939
Path Of Travel In Courtyard
Lights
The vertical clearance height is less than required.
Finding 76.00 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307.4
rovide recommended vertical clearance.
tiority Seven
esolution Not Set
'rogress Not_Started
assignment Not Set
$108
$0.00
Record Number 43940
Path Of Travel In Courtyard
Lamp Circa 1937
The vertical clearance height is less than required.
Finding 78.12 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307.4
rovide recommended vertical clearance.
tiority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$108
$0.00
Record Number 43938
Path Of Travel In Courtyard
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 9.20 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
Provide a compliant path of travel.
tiority Five
esolution Not Set
'rogress Not_Started
_assignment Not Set
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 396 of 853
Record Number 43946
Path Of Travel Along Avenida Montezuma
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 3.00 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
rovide a compliant path of travel.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$3,600
$0.00
Record Number 43972
Path Of Travel From Avenida Mendoza Along Avenida
Montezuma
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 3.40 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
Provide a compliant path of travel.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$3,600
$0.00
Record Number 44047
Path Of Travel To Exit Stairwell Near Alley
Curb On Path Of Travel
There is a curb on the designated path of travel.
Finding Curb Found
ADA 4.3
rovide a compliant curb ramp.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 397 of 853
Record Number 43976
(stall side extensions, modify, relocate, or lower the item so
'at it is not a protruding object into the circulation route.
$640
$0.00
Path Of Travel In Entryway
Donation Box
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 4.37 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
Elevators
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43929
Elevator
There is less than the required depth from the entrance door to
the back wall of the elevator car.
Finding 51.62 inches
Code At least 54.00 inches
ADA 4.10.9
ontact a certified elevator provider to perform all renovation
quired.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$0.00
Record Number 43928
Elevator
There is no signage at the elevator indicating the evacuation plan.
Finding None Found
ADA 4.10
rovide compliant signage indicating evacuation plan and
)utes.
riority Three
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$207
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 398 of 853
Record Number 43931
Elevator
Elevator communication control mounting height is not compliant.
Finding 31.12 inches
Code 35.00 - 48.00 inches
ADA 4.10.14, CA 11B-308, CA 11B-407.4.9
rovide communication controls at a compliant height. Contact
certified elevator provider to perform all renovation required.
tiority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,200
$0.00
Record Number 43932
Elevator
The hall buttons for the elevator are not centered within the
required range above the floor surface.
Finding 42.12 inches
Code 15.00 - 42.00 inches
ADA 4.10.3
ake sure that the elevator controls are located at the
)mpliant height above the finished floor.
tiority Five
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$574
$0.00
Record Number 43930
Elevator
The reopening device for the elevator door does not remain open
for the required amount of time.
Finding Not Accessible
ADA 4.10.6, CA 11B-407.3.3.3
ontact a certified elevator provider to perform all renovation
?quired.
Priority Five
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 399 of 853
Record Number 43933
Elevator
The hoistway signage is not at a compliant height above the
finished floor.
Finding 59.75 inches on center
Code 60.00 inches on center
ADA 4.10.5, CA 11B-407.2.3.1
rovide compliant signage within the elevator hoistways.
riority Five
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$1,500
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43880
Courtyard Stairs To 2nd Floor
Run 1
There is no intermediate handrail available; the width of the
stairway requires that a middle handrail is installed.
Finding None Found
provide an intermediate handrail spaced equally in the middle of
the stair run.
riority Four
esolution Not Set
'rogress Not_Started
ssignment Not Set
$1,528
$0.00
Record Number 43881
Courtyard Stairs To 2nd Floor
Run 2
The width of the stairway does not meet the minimum required
width.
Finding 46.00 inches
Code At least 48.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
Install a stairway with a minimum width as required.
riority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
$8,572
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 400 of 853
Record Number 43882
Courtyard Stairs To 2nd Floor
Run 2 Right Handrail
The surface texture of the wall adjacent to the handrail is sharp
and abrasive.
Finding Near Wall
ADA 4.26.4
odify the surface texture on the wall adjacent to the handrail
) that the surface is smooth.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,320
$0.00
Record Number 43883
Courtyard Stairs To 2nd Floor
Run 2 Right Handrail
The handrail extension is not the required length.
Finding 5.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.3
Tnstall a compliant extension to the handrail.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$627
$0.00
Record Number 43884
Courtyard Stairs To 2nd Floor
Run 2 Left Handrail
The surface texture of the wall adjacent to the handrail is sharp
and abrasive.
Finding Near Wall
ADA 4.26.4
"^odify the surface texture on the wall adjacent to the handrail
) that the surface is smooth.
riority Four
esolution Not Set
'rogress Not_Started
_.ssignment Not Set
$2,320
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 401 of 853
Record Number 43885
Courtyard Stairs To 2nd Floor
Run 3
The width of the stairway does not meet the minimum required
width.
Finding 46.00 inches
Code At least 48.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
(stall a stairway with a minimum width as required.
riority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$8,572
$0.00
Record Number 43886
Courtyard Stairs To 2nd Floor
Run 3 Left Handrail
The surface texture of the wall adjacent to the handrail is sharp
and abrasive.
Finding Near Wall
ADA 4.26.4
Modify the surface texture on the wall adjacent to the handrail
D that the surface is smooth.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,320
$0.00
Record Number 43887
Courtyard Stairs To 2nd Floor
Run 3 Left Handrail
The distance between the handrail and the wall on the stairway is
less than required.
Finding 1.37 inches
Code At least 1.50 inches
ADA 4.9.4(3), CA 11B-505.5
emount the handrails on the stairway so that the distance
om the handrail to the adjacent wall is compliant.
riority Four
.esolution Not Set
'regress Not_Started
..ssignment Not Set
$1,916
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 402 of 853
Record Number 43888
Courtyard Stairs To 2nd Floor
Run 3 Right Handrail
The gripping surface of the handrail is interrupted.
Finding Interrupted
ADA 4.9.4(4)
emount the handrail so is not interrupted.
tiority Four
.esolution Not Set
rogress Not_Started
assignment Not Set
$1,840
$0.00
Record Number 43889
Courtyard Stairs To 2nd Floor
Run 3 Right Handrail
The surface texture of the wall adjacent to the handrail is sharp
and abrasive.
Finding Near Wall
ADA 4.26.4
odify the surface texture on the wall adjacent to the handrail
) that the surface is smooth.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,320
$0.00
Record Number 43890
Courtyard Stairs To 2nd Floor
Run 3 Right Handrail
The distance between the handrail and the wall on the stairway is
less than required.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.9.4(3), CA 11B-505.5
emount the handrails on the stairway so that the distance
om the handrail to the adjacent wall is compliant.
tiority Four
.esolution Not Set
'rogress Not_Started
..ssignment Not Set
$1,916
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 403 of 853
Record Number 43891
Courtyard Stairs To 2nd Floor
Run 3 Right Handrail
The bottom handrail does not extend the depth of one stair tread
beyond the bottom step.
Finding None Found
ADA 4.9.4(2), CA 11B-505.10.3
rovide a compliant handrail extension.
riority Four
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$1,425
$0.00
Record Number 44066
Exit Stairwell 111
Run 1
The stair striping is not a contrasting color.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
Provide compliant contrasting striping to the required treads
id upper approach.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$460
$0.00
Record Number 44067
Exit Stairwell 111
Run 1 Left Handrail
The handrail is not mounted at the required height.
Finding 39.00 inches
Code 34.00 - 38.00 inches
ADA 4.9.4(5), CA 11B-504.6, CA 11B-505
ovide handrail at the required height.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,528
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 404 of 853
Record Number 44069
Exit Stairwell 111
Run 1 Right Handrail
The handrail is not mounted at the required height.
Finding 39.00 inches
Code 34.00 - 38.00 inches
ADA 4.9.4(5), CA 11B-504.6, CA 11B-505
rovide handrail at the required height.
tiority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
$1,528
$0.00
Record Number 44068
Exit Stairwell 111
Run 1 Right Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 5.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
(stall a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$800
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43968
Main Entrance To Courtyard Near Avenida Mendoza
Pull Side
There is no level landing at this door.
Finding 4.10 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
-'rovide a level landing.
riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 405 of 853
Record Number 43967
Main Entrance To Courtyard Near Avenida Mendoza
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 12.00 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance for the door.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,921
$0.00
Record Number 44075
Entrance Gate To Museum Offices
Push Side
There is no level landing at this door.
Finding 2.60 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,500
$0.00
Record Number 44076
Entrance Gate To Museum Offices
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 39.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
Priority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 406 of 853
Record Number 44077
Entrance Gate To Museum Offices
Pull Side
There is no level landing at this door.
Finding 5.90 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Six
.esolution Not Set
'rogress Not_Started
assignment Not Set
$1,500
$0.00
Record Number 44074
Entrance Gate To Museum Offices
Single Knob
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Record Number 43893
Museum Store Entrance
Push / Pull
The door opening force for this door is greater than allowed.
Finding 6.50 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 407 of 853
Record Number 43895
Museum Store Entrance
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
esolution Not Set
rogress Not_Started
assignment Not Set
$50
$0.00
Record Number 43894
Museum Store Entrance
Push / Pull
Door hardware is not mounted at the correct height.
Finding 52.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$280
$0.00
Record Number 43908
Right & Left Entrance Doors To Meeting Room 106 Near
Courtyard
Pull Side
There is no level landing at this door.
Finding 2.40 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Seven
esolution Not Set
'rogress Not_Started
_assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 408 of 853
Record Number 43905
Right & Left Entrance Doors To Meeting Room 106 Near
Courtyard
Push Bar / D Handle
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Record Number 43904
Right & Left Entrance Doors To Meeting Room 106 Near
Courtyard
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$25
$0.00
Record Number 43906
Right & Left Entrance Doors To Meeting Room 106 Near
Courtyard
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 409 of 853
Record Number 43907
Right & Left Entrance Doors To Meeting Room 106 Near
Courtyard
The height of the threshold at the entrance door is greater than
allowed for a vertical rise.
Finding 0.37 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$257
$0.00
Record Number 43909
Meeting Room 106
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
i equirements.
riority Two
.esolution Not Set
'rogress Not_Started
assignment Not Set
$25
$0.00
Record Number 43910
Meeting Room 106
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 410 of 853
Record Number 43912
Entrance Doors To 1st Floor Rotunda
Push Bar / D Handle
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
$400
$0.00
Record Number 43911
Entrance Doors To 1st Floor Rotunda
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$25
$0.00
Record Number 43913
Entrance Doors To 1st Floor Rotunda
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
^emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 411 of 853
Record Number 43916
Exhibit Hall 101 Entrance Near Courtyard
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 43914
Exhibit Hall 101 Entrance Near Courtyard
Push Bar / Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 43915
Exhibit Hall 101 Entrance Near Courtyard
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 412 of 853
Record Number 43918
Door Between Exhibit Hall 101 & Museum Store
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 43919
Door Between Exhibit Hall 101 & Museum Store
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 43934
Classroom 103
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
'rogress Completed
.ssignment Not Set
12/20/2014
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 413 of 853
Record Number 43935
Classroom 103
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$50
$0.00
Record Number 43936
Archives 102
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Corrected
rogress Completed
,ssignment Not Set
10/20/2014
$25
$0.00
Record Number 43937
Archives 102
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 414 of 853
Record Number 43942
Kitchen 107 Entrance Near Courtyard
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 43943
Kitchen 107 Entrance Near Courtyard
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 43944
Kitchen 107 Entrance Near Courtyard
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 415 of 853
Record Number 43947
Exhibit Hall 101
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 4.00 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,000
$0.00
Record Number 43966
Kitchen 107 Entrance Near Trash Area
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 22.37 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
Provide the recommended latch side clearance for the door.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$2,921
$0.00
Record Number 43965
Kitchen 107 Entrance Near Trash Area
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.12 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
Modify or replace the threshold to provide the recommended
neight.
tiority Seven
esolution Not Set
rogress Not_Started
.-ssignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 416 of 853
Record Number 43969
Door Between Exhibit Hall 101 & Archives 102
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 43970
Door Between Exhibit Hall 101 & Archives 102
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 43973
Door Between Meeting Room 106 & Kitchen 107
Push / Pull
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 417 of 853
Record Number 43975
Door Between Meeting Room 106 & Kitchen 107
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
tiority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$50
$0.00
Record Number 43974
Door Between Meeting Room 106 & Kitchen 107
Push / Pull
Door hardware is not mounted at the correct height.
Finding 52.25 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$280
$0.00
Record Number 43982
Exit Stairwell 111 Near Alley
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 18.25 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
Priority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 418 of 853
Record Number 43981
Exit Stairwell 111 Near Alley
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 10.75 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,921
$0.00
Record Number 43980
Exit Stairwell 111 Near Alley
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"lodify or replace the threshold to provide the recommended
eight.
riority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
$436
$0.00
Record Number 43979
Exit Stairwell 111 Near Alley
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 419 of 853
Record Number 44021
Mens Restroom 104
Push / Pull
The door opening force for this door is greater than allowed.
Finding 12.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 44023
Mens Restroom 104
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 44022
Mens Restroom 104
Push / Pull
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 420 of 853
Record Number 44024
Mens Restroom 104
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 44048
Womens Restroom 105
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 44050
Womens Restroom 105
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 421 of 853
Record Number 44049
Womens Restroom 105
Push / Pull
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
$280
$0.00
Record Number 44051
Womens Restroom 105
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 43977
Exit Stairwell 111
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 422 of 853
Record Number 43978
Exit Stairwell 111
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$50
$0.00
Record Number 43985
West Entrance To Exhibit Hall 200
Push / Pull
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 43987
West Entrance To Exhibit Hall 200
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 423 of 853
Record Number 43986
West Entrance To Exhibit Hall 200
Push / Pull
Door hardware is not mounted at the correct height.
Finding 53.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
$280
$0.00
Record Number 44020
Unisex Restroom 206
Pull Side
There is no level landing at this door.
Finding 3.10 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,500
$0.00
Record Number 44018
Unisex Restroom 206
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority One
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 424 of 853
Record Number 44019
Unisex Restroom 206
Push / Pull
Door hardware is not mounted at the correct height.
Finding 51.75 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
$280
$0.00
Record Number 44046
Entrance To Exhibit Hall 3 (204)
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Record Number 44043
Entrance To Exhibit Hall 3 (204)
Push / Pull
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 425 of 853
Record Number 44045
Entrance To Exhibit Hall 3 (204)
Push / Pull
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
rogress Not_Started
assignment Not Set
$50
$0.00
Record Number 44044
Entrance To Exhibit Hall 3 (204)
Push / Pull
Door hardware is not mounted at the correct height.
Finding 53.25 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$280
$0.00
Record Number 44058
North Entrance To Exhibit Hall 200
Push Bar / D Handle
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 426 of 853
Record Number 44057
North Entrance To Exhibit Hall 200
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 44059
North Entrance To Exhibit Hall 200
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 44060
North Entrance To Exhibit Hall 200
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.87 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 427 of 853
Record Number 44070
Door Between Exhibit Hall 3 (204) & Exit Stairwell
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 44071
Door Between Exhibit Hall 3 (204) & Exit Stairwell
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Record Number 43984
Left Office
The clear opening width of the doorway is not compliant.
Finding 29.12 inches
Code At least 32.00 inches
ADA 4.13.5
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Six
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 428 of 853
Record Number 43983
Left Office
The vertical clearance height of the open doorway is not
compliant.
Finding 78.25 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
riority Six
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$5,600
$0.00
Record Number 44009
Main Entrance Near Avenida Montezuma & Avenida Mendoza
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 39.00 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$4,000
$0.00
Record Number 44010
Main Entrance Near Avenida Montezuma & Avenida Mendoza
Push Side
There is no level landing at this door.
Finding 3.20 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 429 of 853
Record Number 44007
Main Entrance Near Avenida Montezuma & Avenida Mendoza
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 7.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,921
$0.00
Record Number 44008
Main Entrance Near Avenida Montezuma & Avenida Mendoza
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 12.00 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
°rovide the recommended latch side clearance for the door.
Priority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,921
$0.00
Record Number 44005
Main Entrance Near Avenida Montezuma & Avenida Mendoza
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 9.00 inches
Code At least 10.00 inches
CA 11B-404.2.10
Install a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Four
.esolution Not Set
'rogress Not_Started
ssignment Not Set
$2,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 430 of 853
Record Number 44003
Main Entrance Near Avenida Montezuma & Avenida Mendoza
Twist / Thumb Latch
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Six
.esolution Not Set
rogress Not_Started
assignment Not Set
$800
$0.00
Record Number 44004
Main Entrance Near Avenida Montezuma & Avenida Mendoza
Twist / Thumb Latch
The door opening force for this door is greater than allowed.
Finding 11.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$25
$0.00
Record Number 44006
Main Entrance Near Avenida Montezuma & Avenida Mendoza
The height of the threshold at the entrance door is greater than
allowed.
Finding 2.12 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 431 of 853
Record Number 44025
Center Office
The clear opening width of the door is less than required.
Finding 27.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,750
$0.00
Record Number 44026
Center Office
The vertical clearance height of the door is less than required.
Finding 78.12 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
tend the height of the doorway to provide the required
earance height.
riority Five
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,000
$0.00
Record Number 44028
Center Office
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 17.00 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 432 of 853
Record Number 44027
Center Office
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Three
esolution Not Set
rogress Not_Started
assignment Not Set
$800
$0.00
Record Number 44073
Right Office
The clear opening width of the doorway is not compliant.
Finding 29.12 inches
Code At least 32.00 inches
ADA 4.13.5
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Seven
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,800
$0.00
Record Number 44072
Right Office
The vertical clearance height of the open doorway is not
compliant.
Finding 78.00 inches
Code At least 80.00 inches
ADA 4.13.5
Provide a compliant open doorway at the location.
tiority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$5,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 433 of 853
Record Number 44078
Unisex Restroom
The clear opening width of the door is less than required.
Finding 25.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,750
$0.00
Record Number 44079
Unisex Restroom
The vertical clearance height of the door is less than required.
Finding 78.50 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
tend the height of the doorway to provide the required
earance height.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,000
$0.00
Record Number 44082
Unisex Restroom
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 17.50 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 434 of 853
Record Number 44083
Unisex Restroom
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 21.25 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Six
.esolution Not Set
'regress Not_Started
Assignment Not Set
$2,921
$0.00
Record Number 44080
Unisex Restroom
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
°rovide accessible hardware on the door.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$800
$0.00
Record Number 44081
Unisex Restroom
Single Knob
Door hardware is not mounted at the correct height.
Finding 51.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
"'bunt the door hardware at the recommended height.
tiority Six
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$280
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 435 of 853
Record Number 43917
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43877
Kitchen 107 Doors
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43879
Museum Store & Exhibit Hall 101 Doors
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
°riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 436 of 853
Record Number 43892
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43898
North Main Entrance To 1st Floor Rotunda
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43899
Meeting Room 106
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 59.00 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 437 of 853
Record Number 43945
Entrance Doors To 1st Floor Rotunda
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43971
Classroom 103 & Archives 102 Doors
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43988
Entrance To Exhibit Hall 3 (204)
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 60.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
tiority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 438 of 853
Record Number 43989
Exit Stairwell 111
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 44002
Entrance Doors To Exhibit Hall 200
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44033
Mens Restroom 104
The shields extend greater than 24" in front of the urinal. The
width between the shields is less than required.
Finding 32.12 inches
Code At least 36.00 inches
ADA 4.18.2, CA 11B-605.3, CA 11B-305.7
modify or replace the urinal shields in the restroom to provide
ie required clearance between the shields for the urinal
2signated as accessible.
riority Six
esolution Not Set
rogress Not_Started
,ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 439 of 853
Record Number 44034
Mens Restroom 104
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 61.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 44035
Mens Restroom 104
Male
The restroom signage is not compliant.
Finding None Found
CA 11B-703.7.2.6.1
°rovide compliant restroom signage.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 44036
Mens Restroom 104
The signage is not mounted at the required height.
Finding 61.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Tost compliant signage at the restroom.
riority Three
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 440 of 853
Record Number 44031
Mens Restroom 104
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.75 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 118-606.2
aise or replace the lavatory to provide the minimum required
iron height.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 44032
Mens Restroom 104
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$1,286
$0.00
Record Number 44030
Mens Restroom 104
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 441 of 853
Record Number 44039
Womens Restroom 105
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.50 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 44040
Womens Restroom 105
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 22.25 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 44037
Womens Restroom 105
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 442 of 853
Record Number 44041
Womens Restroom 105
The toilet paper dispenser is not mounted at the required height.
Finding 16.87 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Record Number 44042
Womens Restroom 105
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
stance from the front edge of the toilet seat.
tiority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$78
$0.00
Record Number 44056
Womens Restroom 105
The signage is not mounted at the required height.
Finding 62.50 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
°riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 443 of 853
Record Number 44055
Womens Restroom 105
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 61.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
3st gender use signage on the center of the door at the
?quired height.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 44053
Womens Restroom 105
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.87 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
°aise or replace the lavatory to provide the minimum required
Dron height.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$2,500
$0.00
Record Number 44054
Womens Restroom 105
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
Raise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
rogress Not_Started
Assignment Not Set
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 444 of 853
Record Number 44052
Womens Restroom 105
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
$277
$0.00
Record Number 44062
Mens Restroom 104
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 23.25 inches
Code At least 24.00 inches
CA 11B-604.5.1
Install or relocate the side grab bar so that the distance from
'ie front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Six
.esolution Not Set
'regress Not_Started
Assignment Not Set
$267
$0.00
Record Number 44063
Mens Restroom 104
The toilet paper dispenser is not mounted at the required height.
Finding 17.00 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser in the compartment to the
required height.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 445 of 853
Record Number 44064
Mens Restroom 104
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
(stance from the front edge of the toilet seat.
riority Three
esolution Not Set
rogress Not_Started
.ssignment Not Set
$78
$0.00
Record Number 44061
Mens Restroom 104
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.37 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 43995
Unisex Restroom 206
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$804
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 446 of 853
Record Number 43999
Unisex Restroom 206
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 40.12 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
°riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$300
$0.00
Record Number 44001
Unisex Restroom 206
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
esolution Not Set
rogress Not_Started
,assignment Not Set
$158
$0.00
Record Number 44000
Unisex Restroom 206
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 447 of 853
Record Number 43998
Unisex Restroom 206
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
_ rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 43996
Unisex Restroom 206
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 48.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
'elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Record Number 43997
Unisex Restroom 206
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 448 of 853
Record Number 44014
Unisex Restroom 206
The distance from the back wall to the front of the grab bar is less
than required.
Finding 52.50 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
priority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 44015
Unisex Restroom 206
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 22.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 44016
Unisex Restroom 206
The toilet paper dispenser is not mounted at the required height.
Finding 16.75 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser in the compartment to the
required height.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 449 of 853
Record Number 44017
Unisex Restroom 206
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
(stance from the front edge of the toilet seat.
riority Three
.esolution Not Set
rogress Not_Started
.ssignment Not Set
$78
$0.00
Record Number 44011
Unisex Restroom 206
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.25 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 44013
Unisex Restroom 206
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 28.25 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 450 of 853
Record Number 44085
Unisex Restroom
There are no grab bars.
Finding None Found
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5
(stall the required grab bars in the toilet compartment.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$267
$0.00
Record Number 44084
Unisex Restroom
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 37.50 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,707
$0.00
Record Number 44086
Unisex Restroom
The shelf is mounted at an incorrect height.
Finding 61.37 inches
Code 36.00 - 48.00 inches
ADA 4.2.5
ount the shelf at the recommended height.
°riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 451 of 853
Record Number 44093
Unisex Restroom
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 22.00 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
priority Three
esolution Not Set
'regress Not_Started
Assignment Not Set
$277
$0.00
Record Number 44088
Unisex Restroom
The height of the toilet seat is not at the required height.
Finding 15.62 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
riority Six
esolution Not Set
'regress Not_Started
.ssignment Not Set
$1,707
$0.00
Record Number 44087
Unisex Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 16.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Six
esolution Not Set
'regress Not_Started
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 452 of 853
Record Number 44090
Unisex Restroom
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$127
$0.00
Record Number 44091
Unisex Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 29.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Six
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
$2,500
$0.00
Record Number 44092
Unisex Restroom
There is less than the required minimum space in front of the
toilet.
Finding 46.50 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
'Treate the required minimum clear space in front of the toilet.
Priority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 453 of 853
Record Number 44095
Unisex Restroom
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,800
$0.00
Record Number 44094
Unisex Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
rnstall a compliant privacy lock with occupancy indicator to the
Dor.
riority Six
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$804
$0.00
Record Number 44096
Unisex Restroom
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 24.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
Modify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
$14,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 454 of 853
Record Number 44097
Unisex Restroom
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
°riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$280
$0.00
Record Number 44098
Unisex Restroom
The entrance door swings into the turning space within the
restroom.
Finding 8.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Six
.esolution Not Set
'regress Not_Started
Assignment Not Set
$8,200
$0.00
Record Number 44108
Unisex Restroom
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 50.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
' ower the mirror so the bottom edge of the reflective surface is
u higher than recommended above the finished floor.
riority Three
.esolution Not Set
'regress Not_Started
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 455 of 853
Record Number 44100
Unisex Restroom
Lavatory
The faucet controls on the lavatory require tight grasping,
pinching, or twisting of the wrist and are not accessible.
Finding Not Accessible
ADA 4.19.5, ADA 309.4, CA 11B-309.4, CA 11B-213, CA 11B-606
(stall accessible faucet controls on the lavatory.
riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$392
$0.00
Record Number 44107
Unisex Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 44101
Unisex Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 26.62 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
apron height.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 456 of 853
Record Number 44102
Unisex Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.75 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,286
$0.00
Record Number 44103
Unisex Restroom
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 12.25 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
°eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Six
.esolution Not Set
rogress Not_Started
assignment Not Set
$2,500
$0.00
Record Number 44104
Unisex Restroom
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 24.50 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
Relocate the lavatory to provide clear floor space.
riority Six
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$2,261
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 457 of 853
Record Number 44105
Unisex Restroom
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 28.00 inches
Code At least 48.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
elocate the lavatory to provide clear floor space.
riority Six
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$2,261
$0.00
Record Number 44106
Unisex Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$149
$0.00
Record Number 44109
Unisex Restroom
All Gender
The gender use signage on the entrance door is not mounted at
the required height.
Finding 66.75 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
. equired height.
riority Three
esolution Not Set
rogress Not_Started
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 458 of 853
Record Number 44110
Unisex Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
esolution Not Set
rogress Not_Started
_,ssignment Not Set
$158
$0.00
Record Number 44099
Unisex Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 52.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Six
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$277
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44065
Drinking Fountain Near Restrooms
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
"eplace the drinking fountain with a compliant High/Low
)untain.
Priority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$2,500
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 459 of 853
Record Number 43990
Visual Alarms
There are some visual warning devices, though visual warning
devices are not located throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, classrooms and
eneral use rooms, accessible restrooms and other accessible
)oms.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
$2,200
$0.00
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43923
Kitchen 107
Sink counter height does not meet the standards.
Finding 36.00 inches
Code Up to 34.00 inches
CA 11B-606.3
'rovide compliant sink.
riority Seven
.esolution Not Set
rogress Not_Started
ssignment Not Set
$1,800
$0.00
Record Number 43924
Kitchen 107
Sink knee clearance does not meet the standards.
Finding 22.87 inches
Code At least 27.00 inches
ADA 4.27
^rovide compliant sink.
riority Seven
.esolution Not Set
rogress Not_Started
ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 460 of 853
Record Number 43925
Kitchen 107
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
ipes under the sink to protect against contact. Make certain
iere are no sharp or abrasive surfaces under the sink.
°riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
$149
$0.00
Record Number 43926
Kitchen 107
Microwave
Appliance Reach Height in the break/conference room is not
compliant.
Finding 59.50 inches
Code Up to 48.00 inches
CA 11B-308, CA 11B-309, CA 11B-205
ake sure that the specified appliance reach height is
)mpliant.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
$1,200
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43900
2nd Floor Balcony Sink
Sink counter height is not compliant.
Finding 36.25 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
'1 R00
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 461 of 853
Record Number 43901
2nd Floor Balcony Sink
Sink knee clearance does not meet the standards.
Finding 23.12 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
rovide compliant sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,800
$0.00
Record Number 43903
2nd Floor Balcony Sink
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Record Number 43902
2nd Floor Balcony Sink
There is not enough toe clearance at the sink.
Finding 7.75 inches
Code At least 9.00 inches
ADA 4.27
ovide minimum required toe clearance.
°riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$900
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 462 of 853
Record Number 43920
Classroom 103
Sink counter height is not compliant.
Finding 36.25 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$1,800
$0.00
Record Number 43921
Classroom 103
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$420
$0.00
Record Number 43922
Classroom 103
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
$149
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 463 of 853
Record Number 43878
1st Floor Rotunda
Alarm System - Other
The highest point of operation for the element is not compliant.
Finding 64.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$50
$0.00
Record Number 43991
Museum Offices
Alarm System - Other
The highest point of operation for the element is not compliant.
Finding 53.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$50
$0.00
Record Number 43992
Museum Offices
Donation Box - Other
The highest point of operation for the element is not compliant.
Finding 57.50 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 464 of 853
Record Number 43993
Museum Offices
Electrical Outlets - Electrical Outlet
The highest point of operation for the element is not compliant.
Finding 11.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$50
$0.00
Record Number 43994
Museum Offices
Thermostat - Thermostat
The highest point of operation for the element is not compliant.
Finding 62.62 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
$50
$0.00
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43896
Benches In Courtyard
The bench height is not compliant.
Finding 16.00 inches
Code 17.00 - 19.00 inches
ADA 5.8, ADA A4.2.6
^,djust the bench height to recommended value.
riority Six
.esolution Not Set
rogress Not_Started
.ssignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 465 of 853
Record Number 43897
Benches In Courtyard
The bench length is not compliant.
Finding 47.25 inches
Code At least 48.00 inches
ADA 5.8, ADA A4.2.6
djust the bench length to recommended value.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$27
$0.00
Record Number 44029
Benches In Exhibit Halls 200 & 204
The bench length is not compliant.
Finding 43.00 inches
Code At least 48.00 inches
ADA 5.8, ADA A4.2.6
Hdjust the bench length to recommended value.
riority Six
esolution Not Set
rogress Not_Started
Assignment Not Set
$27
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 466 of 853
La Quinta Senior Center
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43732
Accessible Parking
There is no device at the head of the general parking spaces to
prevent vehicles from encroaching into walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
)stall a wheel stop at the head of the general parking spaces.
riority Four
esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$240
$0.00
Record Number 43771
Accessible Parking
Parking Lot Warning Sign
Signage height from the finished floor is not compliant.
Finding 28.00 inches
Code At least 36.00 inches
CA 11B-502.8
rovide compliant signage at a compliant height.
riority Seven
esolution Not Set
'rogress Not_Started
.assignment Not Set
06/30/2013
$110
$0.00
Record Number 43733
Accessible Parking
Left Accessible Space Near Calle La Fonda
The accessible parking space does not meet the minimum
requirements for width.
Finding 107.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Four
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 467 of 853
Record Number 43734
Accessible Parking
Left Accessible Space Near Calle La Fonda
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Three
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Record Number 43735
Accessible Parking
Left Accessible Space Near Calle La Fonda
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43736
Accessible Parking
Right Accessible Space Near The South Entrance
The slope of the accessible parking space is not compliant.
Finding 4.00 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$3,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 468 of 853
Record Number 43738
Accessible Parking
Right Accessible Space Near The South Entrance
The surface identification at the designated accessible parking
space is not compliant.
Finding 30.75 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43739
Accessible Parking
Right Accessible Space Near The South Entrance
The bottom edge of the post -mounted signage designating the
accessible parking space is not at the required height.
Finding 61.00 inches
Code At least 80.00 inches
ADA 4.6.4, CA 11B-502.6
°ost signage at a compliant height.
Priority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43737
Accessible Parking
Right Accessible Space Near The South Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
nroyide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 469 of 853
Record Number 43740
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
The accessible parking space does not meet the minimum
requirements for width.
Finding 106.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43741
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
The slope of the accessible parking space is not compliant.
Finding 9.40 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
Repave the accessible space to provide a compliant slope.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$3,800
$0.00
Record Number 43742
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
The vertical clearance of the accessible parking space is less than
required.
Finding 90.75 inches
Code At least 98.00 inches
ADA 4.6.5
rovide sufficient vertical clearance at each accessible parking
Jace.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$108
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 470 of 853
Record Number 43743
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
stall a wheel stop at the head of the accessible parking space.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43744
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
-'rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
Priority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Record Number 43745
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Dace.
riority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 471 of 853
Record Number 43746
Accessible Parking
Center Accessible Space Near The Multi -Purpose Room
The slope of the access aisle is not compliant.
Finding 9.00 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the access aisle to provide a compliant surface slope.
riority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$3,800
$0.00
Record Number 43751
Accessible Parking
Right Accessible Space Near The Multi -Purpose Room
The surface identification at the designated accessible parking
space is not compliant.
Finding 47.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$220
$0.00
Record Number 43747
Accessible Parking
Right Accessible Space Near The Multi -Purpose Room
The slope of the accessible parking space is not compliant.
Finding 14.10 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$3,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 472 of 853
Record Number 43748
Accessible Parking
Right Accessible Space Near The Multi -Purpose Room
The vertical clearance of the accessible parking space is less than
required.
Finding 91.00 inches
Code At least 98.00 inches
ADA 4.6.5
rovide sufficient vertical clearance at each accessible parking
Jace.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$108
$0.00
Record Number 43749
Accessible Parking
Right Accessible Space Near The Multi -Purpose Room
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
Tnstall a wheel stop at the head of the accessible parking space.
tiority Four
.esolution Not Set
'rogress Not_Started
Asignment Not Set
06/30/2013
$250
$0.00
Record Number 43750
Accessible Parking
Right Accessible Space Near The Multi -Purpose Room
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Four
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 473 of 853
Record Number 43752
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The accessible parking space does not meet the minimum
requirements for width.
Finding 103.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43753
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The vertical clearance of the accessible parking space is less than
required.
Finding 90.25 inches
Code At least 98.00 inches
ADA 4.6.5
Provide sufficient vertical clearance at each accessible parking
Dace.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$108
$0.00
Record Number 43754
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
)stall a wheel stop at the head of the accessible parking space.
riority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 474 of 853
Record Number 43756
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The location of the accessible parking spaces requires individuals
with disabilities to travel behind parked cars other than their own.
Finding See Above
CA 11B-502.7
rovide accessible route from the parking space.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43755
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The accessible parking space does not meet the minimum
requirement for length.
Finding 214.00 inches
Code At least 216.00 inches
CA 11B-502.2
Re -stripe the accessible parking space.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43757
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
Provide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 475 of 853
Record Number 43758
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The surface identification at the designated accessible parking
space is not compliant.
Finding 46.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
tiority Four
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43759
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The bottom edge of the post -mounted signage designating the
accessible parking space is not at the required height.
Finding 74.25 inches
Code At least 80.00 inches
ADA 4.6.4, CA 11B-502.6
°ost signage at a compliant height.
Priority Four
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43760
Accessible Parking
Left Accessible Space Near The Multi -Purpose Room
The access aisle does not meet the minimum required width.
Finding 93.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
^e-stripe the access aisle.
tiority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 476 of 853
Record Number 43763
Accessible Parking
Right Accessible Space Near Calle La Fonda
The surface identification at the designated accessible parking
space is not compliant.
Finding 48.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Four
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43762
Accessible Parking
Right Accessible Space Near Calle La Fonda
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
°rovide a minimum fine sign at the parking space below the
International Symbol of Accessibility.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Record Number 43765
Accessible Parking
Left Accessible Space Near The South Entrance
The accessible parking space does not meet the minimum
requirements for width.
Finding 104.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
^e-stripe the accessible parking space.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 477 of 853
Record Number 43766
Accessible Parking
Left Accessible Space Near The South Entrance
The slope of the accessible parking space is not compliant.
Finding 4.90 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
tiority Four
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$3,800
$0.00
Record Number 43764
Accessible Parking
Left Accessible Space Near The South Entrance
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
e-stripe the existing parking space marked as accessible to
fine the width of the space.
tiority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$350
$0.00
Record Number 43767
Accessible Parking
Left Accessible Space Near The South Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 478 of 853
Record Number 43768
Accessible Parking
Left Accessible Space Near The South Entrance
The surface identification at the designated accessible parking
space is not compliant.
Finding 30.75 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$220
$0.00
Record Number 43769
Accessible Parking
Left Accessible Space Near The South Entrance
The slope of the access aisle is not compliant.
Finding 4.50 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
°epave the access aisle to provide a compliant surface slope.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$3,800
$0.00
Record Number 43770
Accessible Parking
Left Accessible Space Near The South Entrance
The access aisle does not contain the wording "No Parking"
painted in white letters within the access aisle.
Finding None Found
CA 11B-502.3.3
paint the words "NO PARKING" a compliant height within the
:cess aisle.
riority Four
esolution Not Set
'rogress Not_Started
_.ssignment Not Set
06/30/2013
$250
$0.00
Passenger Loading Zones
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 479 of 853
Record Number 43824
Passenger Loading Zone
There is no required striped access aisle adjacent to the passenger
loading zone.
Finding None Found
ADA 4.6.6, CA 11B-503.3
tripe a compliant access aisle adjacent and parallel to the
=hicle pull-up space.
°riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$650
$0.00
Record Number 43825
Passenger Loading Zone
There is no signage designating accessibility posted at the
passenger loading zone.
Finding None Found
ADA 4.1.2(7)(b), ADA 4.6.6
Dst compliant signage designating the passenger loading zone
3 accessible.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$400
$0.00
Record Number 43823
Passenger Loading Zone
There are no detectable warning devices provided at the
passenger loading zone.
Finding None Found
ADA 4.29.5
(stall detectable warning devices at the passenger loading
me.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$144
$0.00
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 480 of 853
Record Number 43695
Curb Ramp At The Accessible Spaces Near The South Entrance
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Four
esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$248
$0.00
Record Number 43696
Curb Ramp At The Accessible Spaces Near The South Entrance
The slope of the curb ramp right side flare is greater than allowed.
Finding 12.20 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
rovide curb ramp side flares with a compliant slope.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43697
Curb Ramp At The Accessible Spaces Near The South Entrance
Bottom Landing
The slope at the bottom landing is greater than allowed.
Finding 4.50 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.3.2
rovide a compliant bottom landing that does not exceed the
iaximum slope requirements.
riority Four
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$240
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 481 of 853
Record Number 43698
Curb Ramp At The Accessible Spaces Near The South Entrance
Top Landing
There is not enough top landing clear length.
Finding 36.00 inches
Code At least 48.00 inches
ADA 4.7, CA 11B-406.5.3
rovide a level top landing with enough clear length.
riority Four
esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$240
$0.00
Record Number 43815
Curb Ramp At The Accessible Spaces Near The Multi -Purpose
Room
The curb ramp projects into vehicular traffic lanes, parking spaces,
or parking access aisles.
Finding Projects
ADA 4.7.6, CA 11B-406.5
rovide a compliant curb ramp.
riority Four
esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$1,400
$0.00
Record Number 43816
Curb Ramp At The Accessible Spaces Near The Multi -Purpose
Room
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
Provide compliant detectable warnings to surface.
riority Four
esolution Not Set
rogress Not_Started
ssignment Not Set
06/30/2013
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 482 of 853
Record Number 43817
Curb Ramp At The Accessible Spaces Near The Multi -Purpose
Room
The surface of the curb ramp does not have a finish that contrasts
with the adjacent sidewalk.
ADA 4.7.4
rovide the surface on the curb ramp that contrasts with the
ijacent sidewalk.
tiority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$155
$0.00
Record Number 43818
Curb Ramp At The Accessible Spaces Near The Multi -Purpose
Room
The running slope is greater than allowed.
Finding 9.00 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
Provide a compliant curb ramp.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43819
Curb Ramp At The Accessible Spaces Near The Multi -Purpose
Room
The slope of the curb ramp right side flare is greater than allowed.
Finding 14.10 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
Provide curb ramp side flares with a compliant slope.
Priority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 483 of 853
Record Number 43820
Curb Ramp At The Accessible Spaces Near The Multi -Purpose
Room
Top Landing
The curb ramp does not provide a grooved border along the top
and sides of the ramp at the level of the sidewalk.
Finding None Found
CA 11B-406.5.11
rovide a compliant grooved border along the top and sides of
le curb ramp at the level surface of the sidewalk.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$248
$0.00
Record Number 43850
Curb Ramps Near The Dumpster
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
Provide compliant detectable warnings to surface.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$248
$0.00
Record Number 43851
Curb Ramps Near The Dumpster
The running slope is greater than allowed.
Finding 9.80 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
rovide a compliant curb ramp.
riority Four
,esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 484 of 853
Record Number 43852
Curb Ramps Near The Dumpster
The cross slope is greater than allowed.
Finding 4.80 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.7
rovide a compliant curb ramp.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,300
$0.00
Record Number 43854
Curb Ramps Near The Dumpster
Top Landing
The slope at the top landing is greater than allowed.
Finding 3.80 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.3
rovide a top landing that has a compliant slope and
ianeuvering space.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,260
$0.00
Record Number 43855
Curb Ramps Near The Dumpster
Top Landing
The curb ramp does not provide a grooved border along the top
and sides of the ramp at the level of the sidewalk.
Finding None Found
CA 11B-406.5.11
rovide a compliant grooved border along the top and sides of
le curb ramp at the level surface of the sidewalk.
Priority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 485 of 853
Record Number 43853
atch the transition area at the bottom of the curb ramp so that
le transition is flush and free of abrupt changes.
06/30/2013
$255
$0.00
Curb Ramps Near The Dumpster
Bottom Landing
The transition from the bottom of the curb ramp to the walk,
gutter, or street is abrupt.
Finding 0.62 inches
Code Up to 0.25 inches
ADA 4.5.2, ADA 406.5.8
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43792
Path Of Travel Near Passenger Loading Zone
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 9.30 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$3,600
$0.00
Record Number 43826
Path Of Travel From The Accessible Spaces Near Calle La
Fonda
Crosswalk From The Access Aisle
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
Provide detectable warnings.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 486 of 853
Record Number 43848
Path Of Travel From The Library & The Public Right Of Way
Path Of Travel To The Main Entrance
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
rovide detectable warnings.
riority Four
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$190
$0.00
Record Number 43849
Path Of Travel From The Library & The Public Right Of Way
Path Of Travel To The Main Entrance
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
Provide a compliant crosswalk.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,100
$0.00
Record Number 43847
Path Of Travel From The Library & The Public Right Of Way
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 2.70 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
rovide a compliant path of travel.
riority Seven
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 487 of 853
Record Number 43718
ecurely fasten the mats or carpet runners or replace with a
iat or carpet runner that grips to the underlying floor surface
provide a firm, stable, and slip resistant path of travel.
06/30/2013
$42
$0.00
Path Of Travel In The Lobby
Floor Mats
The mats or carpet runners do not adhere to the underlying floor
surface and slip, thereby creating a hazardous path of travel.
Finding Not Accessible
ADA 4.5.3, CA 11B-403.2, CA 11B-302
riority Two
.esolution Not Set
rogress Not_Started
..ssignment Not Set
Platform Lifts
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43701
Lift In Multi -purpose Room
Platform lift door is not compliant.
Finding Not Accessible
ADA 4.11, CA 11B-410
^rovide a compliant platform lift door.
riority Six
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
06/30/2013
$0.00
Record Number 43699
Lift In Multi -purpose Room
There is no International Symbol of Accessibility found at the
platform lift.
Finding None Found
ADA 4.11, CA 11B-410.8
-'rovide a compliant International Symbol of Accessibitliy at the
latform lift.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$58
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 488 of 853
Record Number 43700
Lift In Multi -purpose Room
There is not enough latch side clearance the pull side of the
platform lift door.
Finding Not Enough Clearance
Code At least 18 inches
ADA 4.11, CA 11B-404.2.4.1
rovide compliant latch side clearance on the pull side of the
latform lift door.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43702
Lift In Multi -purpose Room
There is no light in the car.
Finding None Found
ADA 4.11
rovide a light in the car.
riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$800
$0.00
Record Number 43703
Lift In Multi -purpose Room
There is not standby power for the car.
Finding None Found
ADA 4.11, CA 11B-207.2
-ovide standby power for the car.
°riority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,100
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 489 of 853
Record Number 43704
Lift In Multi -purpose Room
Lift cannot be lowered in case of power loss.
Finding None Found
ADA 4.11, CA 11B-207.2
ake sure that the lift can be lowered in the event of power
Iss.
riority Six
esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$0.00
Record Number 43705
Lift In Multi -purpose Room
Lift device is not red or orange or does not have use instructions.
Finding None Found
ADA 4.11
ake sure that the lowering device is red or orange and has use
istructions.
riority Six
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$300
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43874
Stairs To Multi -purpose Room
Run 1
The width of the stairway does not meet the minimum required
width.
Finding 37.62 inches
Code At least 44.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
Tnstall a stairway with a minimum width as required.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$4,816
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 490 of 853
Record Number 43875
ffix compliant contrasting striping to the upper approach and
3ch tread that is the correct width and distance from the
Dsing.
06/30/2013
$1,000
$0.00
Stairs To Multi -purpose Room
Run 1
There is no detectable striping on the stairways.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
Record Number 43876
Stairs To Multi -purpose Room
Run 1 Right Handrail
The handrail is not mounted at the required height.
Finding 32.00 inches
Code 34.00 - 38.00 inches
ADA 4.9.4(5), CA 11B-504.6, CA 11B-505
°rovide handrail at the required height.
riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,528
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43667
Exterior Doors To The Multi -Purpose Room
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
;25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 491 of 853
Record Number 43791
South Entrance
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43829
Patio Gate Near The Multi -Purpose Room
Pull Side
There is no level landing at this door.
Finding 3.80 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,500
$0.00
Record Number 43828
Patio Gate Near The Multi -Purpose Room
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 2.00 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
Provide the recommended latch side clearance for the door.
riority Four
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 492 of 853
Record Number 43827
Patio Gate Near The Multi -Purpose Room
Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$400
$0.00
Record Number 43870
Arts & Crafts Room, Lounge, Lobby Exterior Doors
The clear opening width of the door is less than required.
Finding 30.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
Widen the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$1,750
$0.00
Record Number 43871
Arts & Crafts Room, Lounge, Lobby Exterior Doors
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
tiority Two
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 493 of 853
Record Number 43872
Arts & Crafts Room, Lounge, Lobby Exterior Doors
Push / Pull
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Six
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$280
$0.00
Record Number 43651
Interior Doors To The Multi -Purpose Room
Push Bar / Lever
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
(stall a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$400
$0.00
Record Number 43652
Interior Doors To The Multi -Purpose Room
Push Bar / Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 494 of 853
Record Number 43666
Multi -Purpose Room Kitchen
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 38.00 inches
Code At least 48.00 inches
ADA 4.13.6
rovide the recommended clear floor space on the push side of
le door.
tiority Six
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43665
Multi -Purpose Room Kitchen
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
°emove the door stop.
tiority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43674
Exterior Door To Kitchen
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 13.25 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide the recommended latch side clearance for the door.
tiority Seven
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 495 of 853
Record Number 43673
Exterior Door To Kitchen
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$436
$0.00
Record Number 43672
Exterior Door To Kitchen
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43671
Exterior Door To Kitchen
Lever
Door hardware is not mounted at the correct height.
Finding 49.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
Mount the door hardware at the recommended height.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 496 of 853
Record Number 43675
Unisex Restroom Near Rear Kitchen Entrance
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 52.75 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the pull side of
le door.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43676
Kitchen Rear Entrance
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 12.12 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
°rovide required latch side clearance on the pull side of the
Dor.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43678
Mens Restroom Near Main Entrance
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 19.50 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
Provide the recommended latch side clearance for the door.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 497 of 853
Record Number 43677
Mens Restroom Near Main Entrance
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43680
Swinging Door To The Reception Counter Area
The clear opening width of the door is less than required.
Finding 31.25 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$1,750
$0.00
Record Number 43691
Lounge & Health Room
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 498 of 853
Record Number 43693
Womens Restroom Near The Health Room
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 25.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,921
$0.00
Record Number 43784
Lobby Door Near The Reception Counter
Push Bar / D Handle
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Two
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$25
$0.00
Record Number 43785
Lobby Door Near The Reception Counter
Push Bar / D Handle
Has a door stop.
Finding Found
CA 11B-404.2.10
^emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 499 of 853
Record Number 43822
Mens Restroom Near The Lounge
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$25
$0.00
Record Number 43830
Arts & Crafts Room
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
emove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43846
Lobby Doors To The Administrative Offices
Lever
Has a door stop.
Finding Found
CA 11B-404.2.10
Remove the door stop.
riority Two
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 500 of 853
Record Number 43831
Lobby Service Counter
The height of the counter or desk does not comply with height
requirements.
Finding 34.25 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Seven
.esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$3,500
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43690
Patio Door To The Arts & Crafts Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
Tnstall compliant room identification signage.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43653
Office Near Rear Kitchen Entrance
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 59.62 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
"rovide compliant signage identifying the accessible entrance on
ie wall adjacent to the latch side of the doorway, mounted at
ie required height and location.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 501 of 853
Record Number 43664
Exterior Door To The Kitchen
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Three
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43670
Multi Purpose Room Kitchen
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 59.62 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43694
Administrative Offices
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
Install compliant room identification signage.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 502 of 853
Record Number 43706
Computer Lab
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 60.62 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43821
Lounge
The accessible entrance signage attached to the wall is not at the
required height above the finished floor.
Finding 60.62 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Provide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43645
Unisex Restroom Near Rear Kitchen Entrance
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 42.62 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
Dwer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
riority Seven
.esolution Not Set
rogress Not_Started
,ssignment Not Set
06/30/2013
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 503 of 853
Record Number 43646
Unisex Restroom Near Rear Kitchen Entrance
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43642
Unisex Restroom Near Rear Kitchen Entrance
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 17.75 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
.rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43643
Unisex Restroom Near Rear Kitchen Entrance
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 504 of 853
Record Number 43644
Unisex Restroom Near Rear Kitchen Entrance
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43647
Unisex Restroom Near Rear Kitchen Entrance
The signage is not mounted at the required height.
Finding 60.25 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43648
Unisex Restroom Near Rear Kitchen Entrance
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
)stall signage that includes the International Symbol of
ccessibility.
tiority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 505 of 853
Record Number 43660
Unisex Restroom Near Rear Kitchen Entrance
The height of the side grab bar is not at the correct height.
Finding 35.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43661
Unisex Restroom Near Rear Kitchen Entrance
The distance from the side wall to the rear grab bar is greater
than allowed.
Finding 6.50 inches
Code Up to 6.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2
emount the rear grab bar at a compliant location.
riority Seven
esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$78
$0.00
Record Number 43658
Unisex Restroom Near Rear Kitchen Entrance
The distance from the back wall to the front of the grab bar is less
than required.
Finding 49.87 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 506 of 853
Record Number 43659
Unisex Restroom Near Rear Kitchen Entrance
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 18.87 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43662
Unisex Restroom Near Rear Kitchen Entrance
The grab bar on the rear wall is not at the correct height.
Finding 35.37 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
Remount the rear grab bar in the compartment designated to
2 accessible so the height of the gripping surface is at the
)rrect height.
tiority Seven
.esolution Not Set
'rogress Not_Started
_,ssignment Not Set
06/30/2013
$231
$0.00
Record Number 43654
Unisex Restroom Near Rear Kitchen Entrance
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.62 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
tiority Seven
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 507 of 853
Record Number 43656
Unisex Restroom Near Rear Kitchen Entrance
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 32.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43657
Unisex Restroom Near Rear Kitchen Entrance
There is less than the required minimum space in front of the
toilet.
Finding 47.37 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Seven
.esolution Not Set
rogress Not_Started
,assignment Not Set
06/30/2013
$3,500
$0.00
Record Number 43663
Unisex Restroom Near Rear Kitchen Entrance
The toilet paper dispenser is not mounted at the required height.
Finding 18.00 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 508 of 853
Record Number 43688
Mens Restroom Near The Lounge
The signage is not mounted at the required height.
Finding 59.00 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
3st compliant signage at the restroom.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
$158
$0.00
Record Number 43689
Mens Restroom Near The Lounge
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
tiority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43687
Mens Restroom Near The Lounge
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
3st gender use signage on the center of the door at the
?quired height.
riority Three
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 509 of 853
Record Number 43686
Mens Restroom Near The Lounge
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43713
Mens Restroom In The Lobby
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Provide an accessible handle mounted on the door of the
Dmpartment near the latch.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43714
Mens Restroom In The Lobby
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 510 of 853
Record Number 43715
Mens Restroom In The Lobby
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43711
Mens Restroom In The Lobby
The height of the side grab bar is not at the correct height.
Finding 34.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43709
Mens Restroom In The Lobby
The distance from the back wall to the front of the grab bar is less
than required.
Finding 52.75 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 511 of 853
Record Number 43710
Mens Restroom In The Lobby
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 23.75 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43712
Mens Restroom In The Lobby
The grab bar on the rear wall is not at the correct height.
Finding 34.50 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
Remount the rear grab bar in the compartment designated to
2 accessible so the height of the gripping surface is at the
)rrect height.
riority Seven
esolution Not Set
'rogress Not_Started
_,ssignment Not Set
06/30/2013
$231
$0.00
Record Number 43716
Mens Restroom In The Lobby
The toilet paper dispenser is not mounted at the required height.
Finding 18.00 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser in the compartment to the
required height.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 512 of 853
Record Number 43707
Mens Restroom In The Lobby
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.00 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43724
Administrative Office Unisex Staff Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
tiority Four
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$804
$0.00
Record Number 43725
Administrative Office Unisex Staff Restroom
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 59.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$14,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 513 of 853
Record Number 43731
Administrative Office Unisex Staff Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Three
esolution Not Set
rogress Not_Started
_,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43727
Administrative Office Unisex Staff Restroom
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 9.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Seven
.esolution Not Set
.rogress Not_Started
Assignment Not Set
$2,500
$0.00
Record Number 43728
Administrative Office Unisex Staff Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Two
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 514 of 853
Record Number 43729
Administrative Office Unisex Staff Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Two
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$149
$0.00
Record Number 43730
Administrative Office Unisex Staff Restroom
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
tiority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43726
Administrative Office Unisex Staff Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Seven
.esolution Not Set
'rogress Not_Started
assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 515 of 853
Record Number 43780
Mens Restroom Near The Lounge
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
°riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Record Number 43781
Mens Restroom Near The Lounge
The clear opening width of the doorway to the compartment is
less than required.
Finding 32.50 inches
Code At least 34.00 inches
ADA 4.13.5, CA 11B-404.2.3, CA 11B-604.8.1.2
liden the doorway to provide a compliant clear opening width
hen the door is open 90 degrees.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43782
Mens Restroom Near The Lounge
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Adjust the inside handle so that it is located near the latch.
°riority Four
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 516 of 853
Record Number 43778
Mens Restroom Near The Lounge
The height of the side grab bar is not at the correct height.
Finding 35.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
tiority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43776
Mens Restroom Near The Lounge
The distance from the back wall to the front of the grab bar is less
than required.
Finding 52.50 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43777
Mens Restroom Near The Lounge
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 23.50 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 517 of 853
Record Number 43779
Mens Restroom Near The Lounge
The grab bar on the rear wall is not at the correct height.
Finding 35.75 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
Priority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Record Number 43774
Mens Restroom Near The Lounge
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$127
$0.00
Record Number 43775
Mens Restroom Near The Lounge
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.62 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
the toilet to the nearest fixture or wall on the wide side.
riority Seven
esolution Not Set
'rogress Not_Started
.-ssignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 518 of 853
Record Number 43772
Mens Restroom Near The Lounge
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.37 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Seven
.esolution Not Set
'regress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43783
Mens Restroom Near The Lounge
The toilet paper dispenser is not mounted at the required height.
Finding 16.50 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Three
.esolution Not Set
'regress Not_Started
.ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43788
Womens Restroom Near The Health Room
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 519 of 853
Record Number 43789
Womens Restroom Near The Health Room
The signage is not mounted at the required height.
Finding 59.75 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
3st compliant signage at the restroom.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Record Number 43790
Womens Restroom Near The Health Room
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43787
Womens Restroom Near The Health Room
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.87 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
Dron height.
Priority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 520 of 853
Record Number 43786
Womens Restroom Near The Health Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43794
Womens Restroom In The Lobby
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.87 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
Raise or replace the lavatory to provide the minimum required
Dron height.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43795
Womens Restroom In The Lobby
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.75 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Seven
.esolution Not Set
'rogress Not_Started
..ssignment Not Set
06/30/2013
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 521 of 853
Record Number 43797
Womens Restroom In The Lobby
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
rogress Not_Started
.ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43796
Womens Restroom In The Lobby
Female
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43793
Womens Restroom In The Lobby
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Four
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 522 of 853
Record Number 43801
Mens Restroom In The Lobby
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$158
$0.00
Record Number 43800
Mens Restroom In The Lobby
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.12 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$1,286
$0.00
Record Number 43802
Mens Restroom In The Lobby
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
(stall signage that includes the International Symbol of
ccessibility.
riority Three
.esolution Not Set
'rogress Not_Started
.,ssignment Not Set
06/30/2013
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 523 of 853
Record Number 43798
Mens Restroom In The Lobby
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43799
Mens Restroom In The Lobby
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43803
Womens Restroom Near The Health Room
There is insufficient clear floor space in the compartment.
Finding 59.75 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
Modify or replace the compartment to provide adequate clear
Dor space.
riority Seven
.esolution Not Set
'regress Not_Started
.,ssignment Not Set
06/30/2013
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 524 of 853
Record Number 43812
Womens Restroom Near The Health Room
The coat hook is not mounted at the correct height.
Finding 63.12 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43810
Womens Restroom Near The Health Room
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
djust the inside handle so that it is located near the latch.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Record Number 43811
Womens Restroom Near The Health Room
There is less than the required latch side clearance on the pull side
of the door.
Finding 12.75 inches
Code At least 18.00 inches
ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404
rovide required latch side clearance on the pull side of the
Dor.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 525 of 853
Record Number 43808
Womens Restroom Near The Health Room
The height of the side grab bar is not at the correct height.
Finding 35.62 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43807
Womens Restroom Near The Health Room
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 23.87 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43809
Womens Restroom Near The Health Room
The grab bar on the rear wall is not at the correct height.
Finding 35.25 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
Remount the rear grab bar in the compartment designated to
a accessible so the height of the gripping surface is at the
)rrect height.
riority Four
esolution Not Set
'rogress Not_Started
.-ssignment Not Set
06/30/2013
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 526 of 853
Record Number 43813
Womens Restroom Near The Health Room
The toilet paper dispenser is not mounted at the required height.
Finding 17.25 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
riority Four
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43814
Womens Restroom Near The Health Room
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 12.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
$277
$0.00
Record Number 43806
Womens Restroom Near The Health Room
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.62 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 527 of 853
Record Number 43804
Womens Restroom Near The Health Room
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43833
Administrative Office Unisex Staff Restroom
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 50.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43832
Administrative Office Unisex Staff Restroom
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Three
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 528 of 853
Record Number 43840
Administrative Office Unisex Staff Restroom
The grab bar on the rear wall is not at the correct height.
Finding 35.25 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Record Number 43839
Administrative Office Unisex Staff Restroom
The height of the side grab bar is not at the correct height.
Finding 35.00 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43837
Administrative Office Unisex Staff Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 49.75 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 529 of 853
Record Number 43838
Administrative Office Unisex Staff Restroom
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 20.25 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
tiority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$267
$0.00
Record Number 43835
Administrative Office Unisex Staff Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 27.25 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Six
esolution Not Set
'rogress Not_Started
_,ssignment Not Set
06/30/2013
$2,500
$0.00
Record Number 43836
Administrative Office Unisex Staff Restroom
There is less than the required minimum space in front of the
toilet.
Finding 42.50 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
'Treate the required minimum clear space in front of the toilet.
Priority Six
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 530 of 853
Record Number 43841
Administrative Office Unisex Staff Restroom
The toilet paper dispenser is not mounted at the required height.
Finding 18.00 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
riority Four
esolution Not Set
'regress Not_Started
.ssignment Not Set
06/30/2013
$277
$0.00
Record Number 43856
Womens Restroom In The Lobby
There is insufficient clear floor space in the compartment.
Finding 58.50 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
odify or replace the compartment to provide adequate clear
Dor space.
riority Seven
esolution Not Set
'regress Not_Started
.ssignment Not Set
06/30/2013
$4,000
$0.00
Record Number 43862
Womens Restroom In The Lobby
The door to the compartment does not have an accessible handle
on both sides.
Finding Not on both sides.
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
rovide an accessible handle mounted on the door of the
)mpartment near the latch.
riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 531 of 853
Record Number 43863
Womens Restroom In The Lobby
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
°riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$269
$0.00
Record Number 43864
Womens Restroom In The Lobby
The door to the compartment designated to be accessible in the
restroom does not have appropriate accessible hardware.
Finding Not Accessible
ADA 4.13.9, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7, CA 11B-6
04.8.1.2
(stall accessible hardware on the compartment door that does
Dt require tight grasping, pinching, or twisting of the wrist.
riority Four
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$289
$0.00
Record Number 43865
Womens Restroom In The Lobby
The inside handle is not located near the latch.
Finding None Found
ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2
Adjust the inside handle so that it is located near the latch.
'riority Four
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$129
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 532 of 853
Record Number 43860
Womens Restroom In The Lobby
The height of the side grab bar is not at the correct height.
Finding 34.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$500
$0.00
Record Number 43861
Womens Restroom In The Lobby
The grab bar on the rear wall is not at the correct height.
Finding 34.25 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$231
$0.00
Record Number 43857
Womens Restroom In The Lobby
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 533 of 853
Record Number 43859
Womens Restroom In The Lobby
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
tiority Six
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$127
$0.00
Record Number 43866
Womens Restroom In The Lobby
The toilet paper dispenser is not mounted at the required height.
Finding 18.00 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser in the compartment to the
iequired height.
tiority Seven
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$277
$0.00
Record Number 43867
Womens Restroom In The Lobby
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 12.75 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
Remount the toilet paper dispenser at a compliant height and
location.
tiority Seven
.esolution Not Set
'rogress Not_Started
.-ssignment Not Set
06/30/2013
$277
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 534 of 853
Record Number 43873
Drinking Fountain In The Lobby
The spout outlet height is greater than required.
Finding 37.50 inches
Code Up to 36.00 inches
ADA 4.15.2, CA 11B-602.4
rovide a spout outlet that does not exceed the required height.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$627
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43679
Visual Alarms
There are visual warning devices provided throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
Since visual warning devices are provided in all areas of the
icility, no additional action is required.
Priority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$0.00
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43720
Staff Lounge
Sink knee clearance does not meet the standards.
Finding 26.75 inches
Code At least 27.00 inches
ADA 4.27
rovide compliant sink.
riority Seven
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 535 of 853
Record Number 43721
Staff Lounge
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
Ipes under the sink to protect against contact. Make certain
iere are no sharp or abrasive surfaces under the sink.
°riority Two
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$149
$0.00
Record Number 43722
Staff Lounge
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Four
esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$110
$0.00
Record Number 43719
Staff Lounge
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
Install an International Symbol of Accessibility at the table.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$158
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 536 of 853
Record Number 43649
Kitchen
There is not enough clear floor space at the sink.
Finding 23.00 inches
Code At least 30.00 inches
ADA 4.27
rovide enough clear floor space at the location.
riority Seven
esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$900
$0.00
Record Number 43650
Kitchen
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 40.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Seven
esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43668
Office Near Rear Kitchen Entrance
Twist controls are present on the sink.
Finding Needs Twisting
ADA 4.27
Provide compliant controls for the sink.
°riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$392
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 537 of 853
Record Number 43669
Office Near Rear Kitchen Entrance
Sink counter height is not compliant.
Finding 34.12 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Seven
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$1,800
$0.00
Record Number 43681
Arts & Crafts
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$420
$0.00
Record Number 43682
Arts & Crafts
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
°riority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 538 of 853
Record Number 43683
Arts & Crafts
There is not enough clear floor space at the sink.
Finding 28.50 inches
Code At least 30.00 inches
ADA 4.27
,ovide enough clear floor space at the location.
tiority Four
esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$900
$0.00
Record Number 43684
Arts & Crafts
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Three
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43685
Arts & Crafts
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 46.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Three
.esolution Not Set
'rogress Not_Started
_assignment Not Set
06/30/2013
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 539 of 853
Record Number 43868
Sink Near The Health Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Record Number 43869
Sink Near The Health Room
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Four
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$180
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43717
Patio Picnic Tables
The required percentage of picnic tables provided are not
accessible.
Finding None Found
Code At least 1.00 tables
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
"rovide a sufficient number of compliant picnic tables.
riority Three
.esolution Not Set
'regress Not_Started
,ssignment Not Set
06/30/2013
$500
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 540 of 853
Record Number 43692
First Aid Kit In The Administrative Office Unisex Staff
Restroom
First Aid Kit - Other
The highest point of operation for the element is not compliant.
Finding 64.50 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
'rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43723
Phones In The Lounge, Arts & Crafts Room
Phone - Other
The highest point of operation for the element is not compliant.
Finding 58.62 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
"lake sure that the highest point of operation is within the
?commended value.
riority Three
.esolution Not Set
rogress Not_Started
Assignment Not Set
06/30/2013
$50
$0.00
Record Number 43842
Computer Lab
Computer Station - Computer Station
The clear floor space width is not compliant.
Finding 27.50 inches
Code At least 30.00 inches
ADA 4.2, CA 11B-305
'rovide compliant clear floor space.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 541 of 853
Record Number 43843
djust knee height to the recommended value.
06/30/2013
$500
$0.00
Computer Lab
Computer Station - Computer Station
The knee height is not compliant.
Finding 24.75 inches
Code At least 27.00 inches
ADA 4.2
riority Seven
.esolution Not Set
rogress Not_Started
assignment Not Set
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 43844
Benches Near The Main Entrance
The bench height is not compliant.
Finding 16.25 inches
Code 17.00 - 19.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench height to recommended value.
riority Seven
.esolution Not Set
'rogress Not_Started
,ssignment Not Set
06/30/2013
$800
$0.00
Record Number 43845
Benches Near The Main Entrance
The bench length is not compliant.
Finding 43.50 inches
Code At least 48.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench length to recommended value.
riority Seven
.esolution Not Set
'rogress Not_Started
.ssignment Not Set
06/30/2013
$27
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 542 of 853
La Quinta YMCA Daycare
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30904
Accessible Parking
The minimum number of accessible parking spaces are not
provided in the parking lot.
Finding 2.00 spaces
Code At least 3.00 spaces
ADA 4.1.2(5), CA 11B-208.2
e-stripe any existing parking spaces marked accessible and
-eate additional accessible parking spaces.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$370
$0.00
Record Number 30905
Accessible Parking
There is no designated "van accessible" parking space provided in
the parking lot.
Finding None Found
ADA 4.1.2(5), CA 11B-208.2.4, CA 11B-502.7
rovide a compliant van accessible space.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$370
$0.00
Record Number 30906
Accessible Parking
There is no device at the head of the general parking spaces to
prevent vehicles from encroaching into walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
)stall a wheel stop at the head of the general parking spaces.
riority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
240
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 543 of 853
Record Number 30924
Accessible Parking
Parking Lot Warning Sign
The point of contact and telephone number for reclaiming towed
vehicles have been left blank.
Finding Sign not Filled
CA 11B-502.8.2
II in the blank spaces with the point of contact and telephone
umber for reclaiming towed vehicles.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 30911
Accessible Parking
Right Accessible Space
The slope of the access aisle is not compliant.
Finding 14.60 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
°epave the access aisle to provide a compliant surface slope.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$3,800
$0.00
Record Number 30914
Accessible Parking
Right Accessible Space
The access aisle does not contain the wording "No Parking"
painted in white letters within the access aisle.
Finding None Found
CA 11B-502.3.3
paint the words "NO PARKING" a compliant height within the
:cess aisle.
tiority Not Set
.esolution Not Set
'rogress Not Set
_.ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 544 of 853
Record Number 30912
Accessible Parking
Right Accessible Space
The access aisle markings are faded, damaged, or otherwise not
viewable.
Finding None Found
CA 11B-502.3
e-stripe the access aisle so as to discourage parking.
tiority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$250
$0.00
Record Number 30913
Accessible Parking
Right Accessible Space
The hatched lines are striped a noncompliant distance on center.
Finding Not on 36" center
CA 11B-502.3.3
Re -stripe the hatched lines in a contrasting color at a compliant
'istance on center.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$350
$0.00
Record Number 30910
Accessible Parking
Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 52.50 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 545 of 853
Record Number 30908
Accessible Parking
Right Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.70 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$3,800
$0.00
Record Number 30907
Accessible Parking
Right Accessible Space
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
e-stripe the existing parking space marked as accessible to
fine the width of the space.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$350
$0.00
Record Number 30909
Accessible Parking
Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 546 of 853
Record Number 30915
Accessible Parking
Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 98.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$350
$0.00
Record Number 30916
Accessible Parking
Left Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
Repave the accessible space to provide a compliant slope.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$3,800
$0.00
Record Number 30917
Accessible Parking
Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
'riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 547 of 853
Record Number 30919
Accessible Parking
Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 52.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
tiority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$220
$0.00
Record Number 30918
Accessible Parking
Left Accessible Space
ISA surface identification is faded and not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.6.4
°epaint the ISA surface identification in the parking space.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$117
$0.00
Record Number 30920
Accessible Parking
Left Accessible Space
The slope of the access aisle is not compliant.
Finding 10.10 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
^epave the access aisle to provide a compliant surface slope.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$3,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 548 of 853
Record Number 30923
Accessible Parking
Left Accessible Space
The access aisle does not contain the wording "No Parking"
painted in white letters within the access aisle.
Finding None Found
CA 11B-502.3.3
aint the words "NO PARKING" a compliant height within the
:cess aisle.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 30921
Accessible Parking
Left Accessible Space
The access aisle markings are faded, damaged, or otherwise not
viewable.
Finding None Found
CA 11B-502.3
De -stripe the access aisle so as to discourage parking.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 30922
Accessible Parking
Left Accessible Space
The hatched lines are striped a noncompliant distance on center.
Finding Not on 36" center
CA 11B-502.3.3
'e-stripe the hatched lines in a contrasting color at a compliant
stance on center.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$350
$0.00
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 549 of 853
Record Number 31244
Curb Ramp At The Right Access Aisle
The curb ramp projects into vehicular traffic lanes, parking spaces,
or parking access aisles.
Finding Projects
ADA 4.7.6, CA 11B-406.5
rovide a compliant curb ramp.
riority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$1,400
$0.00
Record Number 31245
Curb Ramp At The Right Access Aisle
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
,assignment Not Set
$248
$0.00
Record Number 31246
Curb Ramp At The Right Access Aisle
The running slope is greater than allowed.
Finding 14.60 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
Provide a compliant curb ramp.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 550 of 853
Record Number 31247
Curb Ramp At The Right Access Aisle
Top Landing
The curb ramp does not provide a grooved border along the top
and sides of the ramp at the level of the sidewalk.
Finding None Found
CA 11B-406.5.11
rovide a compliant grooved border along the top and sides of
le curb ramp at the level surface of the sidewalk.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$248
$0.00
Record Number 31248
Curb Ramp At The Left Access Aisle
The curb ramp projects into vehicular traffic lanes, parking spaces,
or parking access aisles.
Finding Projects
ADA 4.7.6, CA 11B-406.5
°rovide a compliant curb ramp.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,400
$0.00
Record Number 31249
Curb Ramp At The Left Access Aisle
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
'rovide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 551 of 853
Record Number 31250
Curb Ramp At The Left Access Aisle
The running slope is greater than allowed.
Finding 10.20 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
rovide a compliant curb ramp.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,300
$0.00
Record Number 31251
Curb Ramp At The Left Access Aisle
Top Landing
The curb ramp does not provide a grooved border along the top
and sides of the ramp at the level of the sidewalk.
Finding None Found
CA 11B-406.5.11
rovide a compliant grooved border along the top and sides of
le curb ramp at the level surface of the sidewalk.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$248
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30978
Path Of Travel From The Public Right Of Way
Crosswalk From The Public Right Of Way
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
rovide detectable warnings.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$19G
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 552 of 853
Record Number 30979
Path Of Travel From The Public Right Of Way
Crosswalk From The Public Right Of Way
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
rovide a compliant crosswalk.
tiority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$1,100
$0.00
Record Number 31090
Path Of Travel From The Right Accessible Space To The Main
Entrance
Concrete Upheavel
There is a change in elevation greater than recommended value.
Finding 1.00 inches
Code Up to 0.25 inches
ADA 4.3.8, CA 11B-303, CA 11B-403.4
nsure that the change in elevation is within the recommended
Slue.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$150
$0.00
Record Number 31088
Path Of Travel From The Right Accessible Space To The Main
Entrance
Open Area
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 6.20 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 553 of 853
Record Number 31089
Path Of Travel From The Right Accessible Space To The Main
Entrance
Open Area
There are cross slopes greater than allowed on the primary path
of travel.
Finding 3.20 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
rovide a compliant path of travel.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$3,600
$0.00
Record Number 31217
Path Of Travel From The Left Accessible Spaces To Classroom
1 Exterior Entrance
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 19.20 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
-'rovide a compliant path of travel.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$3,600
$0.00
Record Number 31218
Path Of Travel From The Left Accessible Spaces To Classroom
1 Exterior Entrance
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 5.40 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
provide a compliant path of travel.
riority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$3,600
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 554 of 853
Record Number 30845
Main Entrance
The door closing device limits the required headroom clearance.
Finding 78.00 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 30847
Main Entrance
Lever
Door hardware is not mounted at the correct height.
Finding 45.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
ount the door hardware at the recommended height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$280
$0.00
Record Number 30860
Unisex Staff Restroom
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 14.00 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 555 of 853
Record Number 30859
Unisex Staff Restroom
Lever
The door opening force for this door is greater than allowed.
Finding 12.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 30933
South Exterior Door To School Age Room 2
The door closing device limits the required headroom clearance.
Finding 77.50 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 30935
South Exterior Door To School Age Room 2
Pull Side
There is no level landing at this door.
Finding 4.20 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 556 of 853
Record Number 30937
North Unisex Restroom In School Age Room 2
The clear opening width of the door is less than required.
Finding 28.00 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 30939
North Unisex Restroom In School Age Room 2
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 45.50 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,000
$0.00
Record Number 30940
North Unisex Restroom In School Age Room 2
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 41.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 557 of 853
Record Number 30980
Girls Restroom In Kindergarten Room
The clear opening width of the door is less than required.
Finding 27.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 30982
Girls Restroom In Kindergarten Room
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 30.00 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,000
$0.00
Record Number 30983
Girls Restroom In Kindergarten Room
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 39.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 558 of 853
Record Number 30984
Exterior Entrance To Pre -School Room 2
The door closing device limits the required headroom clearance.
Finding 77.75 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 30986
Exterior Entrance To Pre -School Room 2
Pull Side
There is no level landing at this door.
Finding 7.10 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 30988
Unisex Restroom In School Age Room 2
The door closing device limits the required headroom clearance.
Finding 78.50 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 559 of 853
Record Number 30990
Unisex Restroom In School Age Room 2
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 4.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 30991
Unisex Restroom In School Age Room 2
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 47.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
°rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,921
$0.00
Record Number 31028
Classroom 1
The door closing device limits the required headroom clearance.
Finding 79.00 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
Replace the door closing device with a device that fits above the
'Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 560 of 853
Record Number 31030
Classroom 1
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 4.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 31051
Exterior Entrance From The Pre-school Room 3 To The Play
Area
The door closing device limits the required headroom clearance.
Finding 77.50 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
°eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$250
$0.00
Record Number 31052
Exterior Entrance From The Pre-school Room 3 To The Play
Area
The clear opening width of the door is less than required.
Finding 27.25 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
'^liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 561 of 853
Record Number 31056
Exterior Entrance From The Pre-school Room 3 To The Play
Area
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 3.00 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 31057
Exterior Entrance From The Pre-school Room 3 To The Play
Area
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 47.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 31058
Exterior Entrance From The Pre-school Room 3 To The Play
Area
Pull Side
There is no level landing at this door.
Finding 2.90 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
provide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 562 of 853
Record Number 31054
Exterior Entrance From The Pre-school Room 3 To The Play
Area
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$25
$0.00
Record Number 31055
Exterior Entrance From The Pre-school Room 3 To The Play
Area
Lever
Door hardware is not mounted at the correct height.
Finding 44.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
"fount the door hardware at the recommended height.
Priority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$280
$0.00
Record Number 31059
Girls Restroom In The Pre -School Room 3
The clear opening width of the door is less than required.
Finding 27.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
'^liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 563 of 853
Record Number 31060
Girls Restroom In The Pre -School Room 3
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 33.50 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 31061
Girls Restroom In The Pre -School Room 3
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 43.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
°rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,921
$0.00
Record Number 31068
North Exterior Entrance To School Age Room 2
The door closing device limits the required headroom clearance.
Finding 77.50 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
Replace the door closing device with a device that fits above the
'Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 564 of 853
Record Number 31070
North Exterior Entrance To School Age Room 2
Pull Side
There is no level landing at this door.
Finding 3.80 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
tiority Not Set
.esolution Not Set
'regress Not Set
assignment Not Set
$1,500
$0.00
Record Number 31071
Door From The Kindergarten Room To The Courtyard
The door closing device limits the required headroom clearance.
Finding 77.25 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
tiority Not Set
.esolution Not Set
'regress Not Set
.ssignment Not Set
$250
$0.00
Record Number 31073
Door From The Kindergarten Room To The Courtyard
Pull Side
There is no level landing at this door.
Finding 6.90 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
tiority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 565 of 853
Record Number 31079
Laundry Room
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 41.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 31078
Laundry Room
The height of the threshold at the entrance door is greater than
allowed.
Finding 5.50 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"lodify or replace the threshold to provide the recommended
eight.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$436
$0.00
Record Number 31077
Laundry Room
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 566 of 853
Record Number 31091
Unisex Restroom In Classroom 1
The vertical clearance height of the open doorway is not
compliant.
Finding 79.00 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
tiority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$5,600
$0.00
Record Number 31126
Exterior Entrance To Kindergarten Room
The door closing device limits the required headroom clearance.
Finding 78.25 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
tiority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 31129
Exterior Entrance To Kindergarten Room
Pull Side
There is no level landing at this door.
Finding 2.30 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 567 of 853
Record Number 31128
Exterior Entrance To Kindergarten Room
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 31147
School Age Room 1 Exterior Entranceway
The door closing device limits the required headroom clearance.
Finding 77.00 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 31149
School Age Room 1 Exterior Entranceway
Pull Side
There is no level landing at this door.
Finding 4.70 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 568 of 853
Record Number 31150
Classroom 2
The door closing device limits the required headroom clearance.
Finding 78.25 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 31152
Classroom 2
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 4.50 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 31160
Door From The Pre -School Room 3 To The Restrooms
The clear opening width of the door is less than required.
Finding 27.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
/iden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 569 of 853
Record Number 31162
Door From The Pre -School Room 3 To The Restrooms
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 2.50 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 31163
Door From The Pre -School Room 3 To The Restrooms
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 57.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
°rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,921
$0.00
Record Number 31165
Unisex Restroom In Classroom 2
The vertical clearance height of the open doorway is not
compliant.
Finding 79.50 inches
Code At least 80.00 inches
ADA 4.13.5
Provide a compliant open doorway at the location.
riority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$5,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 570 of 853
Record Number 31175
Exterior Entrance From Pre -School Room 3 To The Courtyard
The door closing device limits the required headroom clearance.
Finding 77.50 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 31178
Exterior Entrance From Pre -School Room 3 To The Courtyard
Pull Side
There is no level landing at this door.
Finding 5.20 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 31177
Exterior Entrance From Pre -School Room 3 To The Courtyard
Lever
Door hardware is not mounted at the correct height.
Finding 44.50 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
Mount the door hardware at the recommended height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 571 of 853
Record Number 31215
Door From School Age Room 2 To Unisex Restrooms
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 5.00 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 31216
School Age Room 1
The vertical clearance height of the door is less than required.
Finding 70.00 inches
Code At least 78.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
Extend the height of the doorway to provide the required
earance height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,000
$0.00
Record Number 31220
Boys Restroom In the Kindergarten Room
The clear opening width of the door is less than required.
Finding 27.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
'Viden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 572 of 853
Record Number 31222
Boys Restroom In the Kindergarten Room
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 39.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 31232
South Unisex Restroom In School Age Room 2
The clear opening width of the door is less than required.
Finding 27.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
Widen the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,750
$0.00
Record Number 31234
South Unisex Restroom In School Age Room 2
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 45.50 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide the recommended clear floor space on the push side of
le door.
tiority Not Set
esolution Not Set
'rogress Not Set
_.ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 573 of 853
Record Number 31235
South Unisex Restroom In School Age Room 2
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 41.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 31236
Boys Restroom In The Pre -School Room 3
The clear opening width of the door is less than required.
Finding 27.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
Widen the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,750
$0.00
Record Number 31238
Boys Restroom In The Pre -School Room 3
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 33.50 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
provide the recommended clear floor space on the push side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
_.ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 574 of 853
Record Number 31239
rovide the recommended clear floor space on the pull side of
le door.
$2,921
$0.00
Boys Restroom In The Pre -School Room 3
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 39.75 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30815
Reception Counter In The Lobby
The height of the counter or desk does not comply with height
requirements.
Finding 42.25 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Not Set
esolution Not Set
'rogress Not Set
_,ssignment Not Set
$3,500
$0.00
Record Number 30834
Counter In Kitchen
The height of the counter or desk used primarily by children is not
within compliant height ranges for the primary age group.
Finding 36.00 inches
Code 26.00 - 30.00 inches
ADA 4.32.5(3), ADA 7.2, CA 11B-902.4.2
ake sure a portion of the counter is within compliant height
inges to accommodate age group requirements for children.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$545
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 575 of 853
Record Number 30864
Main Entrance To The YMCA Daycare Center
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
)stall accessible room signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31118
Directional Signage From The Accessible Parking To The Main
Entrance
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
Install directional signage to each accessible element or room.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30836
Main Entrance To YMCA Daycare Center
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
Tnstall accessible room signage.
riority Not Set
esolution Not Set
rogress Not Set
ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 576 of 853
Record Number 30848
Copy Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30849
Administrative Reception Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30861
Directors Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 577 of 853
Record Number 30862
CVHC Administrative Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30863
Kitchen
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30903
Exterior Entrance To Pre -School Room 2
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 578 of 853
Record Number 30936
Classroom 2
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
lstall accessible room signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30972
Exterior Entrance From Pre-school Room 3 To Play Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30987
Classroom 1
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 579 of 853
Record Number 30992
Door From Pre -School Room 3 To Restrooms
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31050
School Age Room 1 Exterior Entranceway
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31074
South Exterior Door To School Age Room 2
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 580 of 853
Record Number 31075
Exterior Entrance To Kindergarten Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31080
School Age Room 2 Exterior Entrance
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31081
Door From School Age Room 2 To Childrens Unisex Restrooms
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 581 of 853
Record Number 31164
Exterior Entrance From Pre -School Room 3 To The Foye
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31166
Conference Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31200
Door From Kindergarten To The Foyer
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 582 of 853
Record Number 31201
School Age Room 1
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31219
Laundry Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30818
Unisex Staff Restroom
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
modify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
esolution Not Set
rogress Not Set
,ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 583 of 853
Record Number 30816
Unisex Staff Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$804
$0.00
Record Number 30819
Unisex Staff Restroom
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 58.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 30820
Unisex Staff Restroom
The entrance door swings into the turning space within the
restroom.
Finding 15.50 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$8,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 584 of 853
Record Number 30828
Unisex Staff Restroom
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 42.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$300
$0.00
Record Number 30829
Unisex Staff Restroom
The top of the mirror is not at the compliant height.
Finding 71.75 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 30831
Unisex Staff Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 585 of 853
Record Number 30823
Unisex Staff Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.00 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
iron height.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30824
Unisex Staff Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 24.50 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,286
$0.00
Record Number 30825
Unisex Staff Restroom
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 13.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
Replace or remount lavatory to meet the minimum required
'lstance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
esolution Not Set
.rogress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 586 of 853
Record Number 30826
Unisex Staff Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 30827
Unisex Staff Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 30830
Unisex Staff Restroom
All Gender
The gender use signage on the entrance door is not mounted at
the required height.
Finding 63.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
post gender use signage on the center of the door at the
required height.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 587 of 853
Record Number 30821
Unisex Staff Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 48.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30822
Unisex Staff Restroom
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.40 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30852
Unisex Staff Restroom
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 59.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
tiority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 588 of 853
Record Number 30853
Unisex Staff Restroom
There are no grab bars.
Finding None Found
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5
(stall the required grab bars in the toilet compartment.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 30851
Unisex Staff Restroom
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 30854
Unisex Staff Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 589 of 853
Record Number 30856
Unisex Staff Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 33.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30857
Unisex Staff Restroom
There is less than the required minimum space in front of the
toilet.
Finding 42.25 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$3,500
$0.00
Record Number 30873
Unisex Restroom In Room 1
There is insufficient clear floor space in the compartment.
Finding 59.00 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
odify or replace the compartment to provide adequate clear
Dor space.
tiority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 590 of 853
Record Number 30875
Unisex Restroom In Room 1
There is no door on the compartment designated to be accessible
in the restroom.
Finding None Found
ADA 4.17.5, CA 11B-604.8.1, CA 11B-604.8
(stall a door with appropriate accessible door hardware on the
)mpartment designated to be accessible in the restroom.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 30874
Unisex Restroom In Room 1
Path of travel width to the accessible compartment is not
compliant.
Finding 40.75 inches
Code At least 44.00 inches
ADA A4.17.3, CA 11B-604.8.1.2
ake sure that the path of travel width to the accessible
)mpartment is compliant.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,400
$0.00
Record Number 30879
Unisex Restroom In Room 1
The height of the side grab bar is not at a compliant height for the
primary age group.
Finding 33.25 inches
Code 20.00 - 22.00 inches
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.9
emount the side grab bar in the compartment designated to
e accessible in the restroom at to the required height for use
y the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$78
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 591 of 853
Record Number 30880
Unisex Restroom In Room 1
The grab bar on the rear wall is not at the correct height.
Finding 33.00 inches
Code 20.00 - 22.00 inches
ADA 4.16.7(3), CA 11B-604.9
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Record Number 30878
Unisex Restroom In Room 1
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 39.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30876
Unisex Restroom In Room 1
The distance from the center line of the toilet to the nearest side
wall is not compliant for the primary age group.
Finding 20.00 inches on center
Code 12.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
)r the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 592 of 853
Record Number 30881
Unisex Restroom In Room 1
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$804
$0.00
Record Number 30888
Unisex Restroom In Room 1
The bottom edge of the reflective surface of the mirror in the
restroom is not at a compliant height for the primary age group.
Finding 33.25 inches
Code Up to 32.00 inches
ADA 4.19.6, CA 11B-603.3, CA 11B-604.9
Dwer the mirror in the restroom so that the bottom edge of the
?flective surface is no higher than recommended above the
nish floor.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$291
$0.00
Record Number 30889
Unisex Restroom In Room 1
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
post gender use signage on the center of the door at the
required height.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 593 of 853
Record Number 30886
Unisex Restroom In Room 1
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 30887
Unisex Restroom In Room 1
Lavatory
There is not enough toe clearance at the restroom lavatory.
Finding 6.00 inches
Code At least 9.00 inches
ADA 4.19.2
Provide minimum required toe clearance.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$289
$0.00
Record Number 30883
Unisex Restroom In Room 1
Lavatory
The lavatory is in an enclosed cabinet, thereby preventing an
accessible forward approach.
Finding Not Accessible
ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306
emove or modify the lavatory cabinet and provide a compliant
vatory.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$420
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 594 of 853
Record Number 30884
Unisex Restroom In Room 1
Lavatory
The knee clearance space under the lavatory designated to be
accessible in the restroom is less than the required minimum for
the primary age group.
Finding 18.00 inches
Code At least 19.00 inches
ADA 4.19.2, CA 11B-604.9
einstall or replace the lavatory designated to be accessible
ith an accessible lavatory that provides the required knee
earance for the primary age group.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 30885
Unisex Restroom In Room 1
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 27.00 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
elocate the lavatory to provide clear floor space.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,261
$0.00
Record Number 30890
Unisex Restroom In Room 1
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
tiority Not Set
.esolution Not Set
'rogress Not Set
,.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 595 of 853
Record Number 30882
Unisex Restroom In Room 1
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
ld does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30891
Girls Restroom In The Pre -School Room 3
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,800
$0.00
Record Number 30892
Girls Restroom In The Pre -School Room 3
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 34.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$14,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 596 of 853
Record Number 30893
Girls Restroom In The Pre -School Room 3
The entrance door swings into the turning space within the
restroom.
Finding 13.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$8,200
$0.00
Record Number 30897
Girls Restroom In The Pre -School Room 3
Lavatory
The height of the counter surface of the lavatory designated to be
accessible in the restroom is greater than the allowed maximum
height for the primary age group.
Finding 30.00 inches
Code Up to 24.00 inches
ADA 4.19.2, CA 11B-604.9
Raise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 30898
Girls Restroom In The Pre -School Room 3
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 12.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
'riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 597 of 853
Record Number 30899
Girls Restroom In The Pre -School Room 3
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 30900
Girls Restroom In The Pre -School Room 3
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 30901
Girls Restroom In The Pre -School Room 3
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 67.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Post gender use signage on the center of the door at the
required height.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 598 of 853
Record Number 30902
Girls Restroom In The Pre -School Room 3
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Record Number 30894
Girls Restroom In The Pre -School Room 3
Paper Towel
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 32.50 inches
Code Up to 32.00 inches
ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
elocate the dispenser in the restroom to meet the required
eight for the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30895
Girls Restroom In The Pre -School Room 3
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
ld does not require tight grasping, pinching, or twisting of the
rist.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 599 of 853
Record Number 30896
Girls Restroom In The Pre -School Room 3
Soap
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 39.00 inches
Code Up to 32.00 inches
ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
elocate the dispenser in the restroom to meet the required
eight for the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30941
Unisex Restroom In School Age Room 2
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
)stall a compliant privacy lock with occupancy indicator to the
eor.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$804
$0.00
Record Number 30950
Unisex Restroom In School Age Room 2
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 42.50 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
Dwer the mirror so the bottom edge of the reflective surface is
10 higher than recommended above the finished floor.
riority Not Set
.esolution Not Set
'rogress Not Set
ssignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 600 of 853
Record Number 30951
Unisex Restroom In School Age Room 2
The top of the mirror is not at the compliant height.
Finding 71.75 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 30945
Unisex Restroom In School Age Room 2
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.50 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
Dron height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,500
$0.00
Record Number 30946
Unisex Restroom In School Age Room 2
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 25.00 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 601 of 853
Record Number 30947
Unisex Restroom In School Age Room 2
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 13.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
.esolution Not Set
.:rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30948
Unisex Restroom In School Age Room 2
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
abrasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
rogress Not Set
ssignment Not Set
$149
$0.00
Record Number 30949
Unisex Restroom In School Age Room 2
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 602 of 853
Record Number 30953
Unisex Restroom In School Age Room 2
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Record Number 30952
Unisex Restroom In School Age Room 2
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Record Number 30942
Unisex Restroom In School Age Room 2
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 603 of 853
Record Number 30943
Unisex Restroom In School Age Room 2
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 48.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30944
Unisex Restroom In School Age Room 2
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
Replace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30954
Boys Restroom In The Pre -School Room 3
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 604 of 853
Record Number 30955
Boys Restroom In The Pre -School Room 3
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 42.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 30956
Boys Restroom In The Pre -School Room 3
The entrance door swings into the turning space within the
restroom.
Finding 9.50 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$8,200
$0.00
Record Number 30965
Boys Restroom In The Pre -School Room 3
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
'riority Not Set
esolution Not Set
'rogress Not Set
ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 605 of 853
Record Number 30960
Boys Restroom In The Pre -School Room 3
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 14.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
.esolution Not Set
_ rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30961
Boys Restroom In The Pre -School Room 3
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 47.75 inches
Code At least 48.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
'elocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,261
$0.00
Record Number 30962
Boys Restroom In The Pre -School Room 3
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 606 of 853
Record Number 30963
Boys Restroom In The Pre -School Room 3
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 30959
Boys Restroom In The Pre -School Room 3
Lavatory
The height of the counter surface of the lavatory designated to be
accessible in the restroom is greater than the allowed maximum
height for the primary age group.
Finding 29.50 inches
Code Up to 24.00 inches
ADA 4.19.2, CA 11B-604.9
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,286
$0.00
Record Number 30964
Boys Restroom In The Pre -School Room 3
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 66.50 inches
Code 60.00 inches
CA 11B-703.7.2.6
post gender use signage on the center of the door at the
required height.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 607 of 853
Record Number 30957
Boys Restroom In The Pre -School Room 3
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
-id does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 30958
Boys Restroom In The Pre -School Room 3
Soap
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 39.50 inches
Code Up to 32.00 inches
ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
elocate the dispenser in the restroom to meet the required
eight for the primary age group.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 30967
Girls Restroom In Pre -School Room 3
There are grab bars missing from the toilet compartment.
Finding None Found
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3
Install the required compliant grab bars in the toilet
compartment.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 608 of 853
Record Number 30966
Girls Restroom In Pre -School Room 3
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 58.00 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 30970
Girls Restroom In Pre -School Room 3
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 18.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30971
Girls Restroom In Pre -School Room 3
There is less than the required minimum space in front of the
toilet.
Finding 33.50 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 609 of 853
Record Number 30968
Girls Restroom In Pre -School Room 3
The distance from the center line of the toilet to the nearest side
wall is not compliant for the primary age group.
Finding 18.00 inches on center
Code 12.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
r the primary age group.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 30994
South Unisex Restroom In School Age Room 2
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
Modify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 30995
South Unisex Restroom In School Age Room 2
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 28.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
"odify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
.esolution Not Set
'rogress Not Set
.assignment Not Set
$14,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 610 of 853
Record Number 30996
South Unisex Restroom In School Age Room 2
The entrance door swings into the turning space within the
restroom.
Finding 10.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$8,200
$0.00
Record Number 31004
South Unisex Restroom In School Age Room 2
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
'riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 30998
South Unisex Restroom In School Age Room 2
Lavatory
The height of the counter surface of the lavatory designated to be
accessible in the restroom is greater than the allowed maximum
height for the primary age group.
Finding 30.50 inches
Code Up to 29.00 inches
ADA 4.19.2, CA 11B-606.2
Raise or replace the lavatory to provide the minimum required
knee clearance.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 611 of 853
Record Number 30999
South Unisex Restroom In School Age Room 2
Lavatory
The knee clearance space under the lavatory designated to be
accessible in the restroom is less than the required minimum for
the primary age group.
Finding 23.50 inches
Code At least 24.00 inches
ADA 4.19.2, CA 11B-606.2
einstall or replace the lavatory designated to be accessible
ith an accessible lavatory that provides the required knee
earance for the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 31000
South Unisex Restroom In School Age Room 2
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 13.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 31001
South Unisex Restroom In School Age Room 2
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Thsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 612 of 853
Record Number 31002
South Unisex Restroom In School Age Room 2
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 31003
South Unisex Restroom In School Age Room 2
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$158
$0.00
Record Number 30997
South Unisex Restroom In School Age Room 2
Soap
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 39.50 inches
Code Up to 36.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
Relocate the dispenser in the restroom to meet the required
eight for the primary age group.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 613 of 853
Record Number 31031
Girls Restroom In The Kindergarten Room
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31032
Girls Restroom In The Kindergarten Room
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 38.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
Modify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 31033
Girls Restroom In The Kindergarten Room
The entrance door swings into the turning space within the
restroom.
Finding 9.50 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
sufficient clear floor space for a turning radius in the restroom
to accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
.assignment Not Set
$8,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 614 of 853
Record Number 31040
Girls Restroom In The Kindergarten Room
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 68.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31035
Girls Restroom In The Kindergarten Room
Lavatory
The height of the counter surface of the lavatory designated to be
accessible in the restroom is greater than the allowed maximum
height for the primary age group.
Finding 29.50 inches
Code Up to 24.00 inches
ADA 4.19.2, CA 11B-604.9
°aise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,286
$0.00
Record Number 31036
Girls Restroom In The Kindergarten Room
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 11.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
Replace or remount lavatory to meet the minimum required
distance to the center line of the fixture, when located adjacent
to a side wall or partition.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 615 of 853
Record Number 31037
Girls Restroom In The Kindergarten Room
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 47.50 inches
Code At least 48.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
elocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,261
$0.00
Record Number 31038
Girls Restroom In The Kindergarten Room
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
'riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 31039
Girls Restroom In The Kindergarten Room
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 616 of 853
Record Number 31041
Girls Restroom In The Kindergarten Room
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Record Number 31034
Girls Restroom In The Kindergarten Room
Soap
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 39.50 inches
Code Up to 32.00 inches
ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
elocate the dispenser in the restroom to meet the required
eight for the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 31082
North Unisex Restroom In School Age Room 2
There are grab bars missing from the toilet compartment.
Finding None Found
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3
)stall the required compliant grab bars in the toilet
,.ompartment.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 617 of 853
Record Number 31083
North Unisex Restroom In School Age Room 2
The height of the toilet seat in the restroom is greater than the
allowed maximum height for use by the primary age group.
Finding 16.00 inches
Code 15.00 inches
ADA 4.16.7(3), CA 11B-604.9.3
djust or modify the height of the toilet seat in the restroom to
le required height for use by the primary age group.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 31084
North Unisex Restroom In School Age Room 2
The distance from the center line of the toilet to the nearest side
wall in the restroom is not at the required distance.
Finding 18.00 inches on center
Code 15.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
)r use by the primary age group.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 31086
North Unisex Restroom In School Age Room 2
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 22.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
the toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 618 of 853
Record Number 31087
North Unisex Restroom In School Age Room 2
There is less than the required minimum space in front of the
toilet.
Finding 30.50 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$3,500
$0.00
Record Number 31104
Mens Restroom
The restroom is not accessible and cannot be easily altered.
There is not sufficient clear floor space to accommodate an
individual in a wheelchair.
Finding Not Accessible
ADA 4.23
onsult a design professional to modify the restroom for access
)mpliance.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 31106
Unisex Restroom In School Age Room 2
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 56.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 619 of 853
Record Number 31105
Unisex Restroom In School Age Room 2
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 31115
Unisex Restroom In School Age Room 2
The height of the side grab bar is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
Remount the grab bar so it is at the correct height.
'riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 31116
Unisex Restroom In School Age Room 2
The grab bar on the rear wall is not at the correct height.
Finding 33.25 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
Remount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 620 of 853
Record Number 31112
Unisex Restroom In School Age Room 2
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 31113
Unisex Restroom In School Age Room 2
The distance from the back wall to the front of the grab bar is less
than required.
Finding 46.50 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 31114
Unisex Restroom In School Age Room 2
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 16.50 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 621 of 853
Record Number 31107
Unisex Restroom In School Age Room 2
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.25 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
Priority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 31109
Unisex Restroom In School Age Room 2
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$127
$0.00
Record Number 31110
Unisex Restroom In School Age Room 2
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 36.25 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
the toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 622 of 853
Record Number 31111
Unisex Restroom In School Age Room 2
There is less than the required minimum space in front of the
toilet.
Finding 47.00 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$3,500
$0.00
Record Number 31117
Unisex Restroom In School Age Room 2
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 19.00 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 31120
Girls Restroom In Kindergarten Room
There are grab bars missing from the toilet compartment.
Finding None Found
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3
(stall the required compliant grab bars in the toilet
)mpartment.
riority Not Set
esolution Not Set
'rogress Not Set
.,ssignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 623 of 853
Record Number 31119
Girls Restroom In Kindergarten Room
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 57.25 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 31121
Girls Restroom In Kindergarten Room
The distance from the center line of the toilet to the nearest side
wall is not compliant for the primary age group.
Finding 20.00 inches on center
Code 12.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
)r the primary age group.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 31123
Girls Restroom In Kindergarten Room
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
Relocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$127
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 624 of 853
Record Number 31124
Girls Restroom In Kindergarten Room
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 9.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 31125
Girls Restroom In Kindergarten Room
There is less than the required minimum space in front of the
toilet.
Finding 29.00 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$3,500
$0.00
Record Number 31131
Boys Restroom In the Kindergarten Room
There are grab bars missing from the toilet compartment.
Finding None Found
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3
(stall the required compliant grab bars in the toilet
)mpartment.
riority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 625 of 853
Record Number 31130
Boys Restroom In the Kindergarten Room
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 59.50 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 31132
Boys Restroom In the Kindergarten Room
The distance from the center line of the toilet to the nearest side
wall is not compliant for the primary age group.
Finding 18.50 inches on center
Code 12.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
)r the primary age group.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 31134
Boys Restroom In the Kindergarten Room
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
Relocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$127
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 626 of 853
Record Number 31135
Boys Restroom In the Kindergarten Room
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 18.25 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 31136
Boys Restroom In the Kindergarten Room
There is less than the required minimum space in front of the
toilet.
Finding 30.00 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$3,500
$0.00
Record Number 31137
Unisex Restroom In Classroom 2
There is insufficient clear floor space in the compartment.
Finding 59.00 inches
Code At least 60.00 inches
ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1
odify or replace the compartment to provide adequate clear
Dor space.
riority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 627 of 853
Record Number 31139
Unisex Restroom In Classroom 2
There is no door on the compartment designated to be accessible
in the restroom.
Finding None Found
ADA 4.17.5, CA 11B-604.8.1, CA 11B-604.8
(stall a door with appropriate accessible door hardware on the
)mpartment designated to be accessible in the restroom.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 31138
Unisex Restroom In Classroom 2
Path of travel width to the accessible compartment is not
compliant.
Finding 41.00 inches
Code At least 44.00 inches
ADA A4.17.3, CA 11B-604.8.1.2
ake sure that the path of travel width to the accessible
)mpartment is compliant.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,400
$0.00
Record Number 31143
Unisex Restroom In Classroom 2
The height of the side grab bar is not at a compliant height for the
primary age group.
Finding 33.00 inches
Code 20.00 - 22.00 inches
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.9
emount the side grab bar in the compartment designated to
e accessible in the restroom at to the required height for use
y the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$78
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 628 of 853
Record Number 31144
Unisex Restroom In Classroom 2
The grab bar on the rear wall is not at the correct height.
Finding 33.00 inches
Code 20.00 - 22.00 inches
ADA 4.16.7(3), CA 11B-604.9
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
Priority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Record Number 31140
Unisex Restroom In Classroom 2
The distance from the center line of the toilet to the nearest side
wall is not compliant for the primary age group.
Finding 19.25 inches on center
Code 12.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
)r the primary age group.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 31142
Unisex Restroom In Classroom 2
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
the toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 629 of 853
Record Number 31145
Unisex Restroom In Classroom 2
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
(stance from the front edge of the toilet seat.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$78
$0.00
Record Number 31169
Boys Restroom In Pre -School Room 3
There are grab bars missing from the toilet compartment.
Finding None Found
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3
(stall the required compliant grab bars in the toilet
)mpartment.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$231
$0.00
Record Number 31168
Boys Restroom In Pre -School Room 3
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 57.75 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 630 of 853
Record Number 31172
Boys Restroom In Pre -School Room 3
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
tiority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$127
$0.00
Record Number 31173
Boys Restroom In Pre -School Room 3
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 9.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
_,ssignment Not Set
$2,500
$0.00
Record Number 31174
Boys Restroom In Pre -School Room 3
There is less than the required minimum space in front of the
toilet.
Finding 31.25 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
'Treate the required minimum clear space in front of the toilet.
Priority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 631 of 853
Record Number 31170
Boys Restroom In Pre -School Room 3
The distance from the center line of the toilet to the nearest side
wall is not compliant for the primary age group.
Finding 18.00 inches on center
Code 12.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
r the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 31181
North Unisex Restroom In School Age Room 2
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
Modify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31180
North Unisex Restroom In School Age Room 2
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$804
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 632 of 853
Record Number 31182
North Unisex Restroom In School Age Room 2
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 29.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 31183
North Unisex Restroom In School Age Room 2
The entrance door swings into the turning space within the
restroom.
Finding 10.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$8,200
$0.00
Record Number 31191
North Unisex Restroom In School Age Room 2
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 633 of 853
Record Number 31192
North Unisex Restroom In School Age Room 2
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Record Number 31186
North Unisex Restroom In School Age Room 2
Lavatory
The height of the counter surface of the lavatory designated to be
accessible in the restroom is greater than the allowed maximum
height for the primary age group.
Finding 30.50 inches
Code Up to 29.00 inches
ADA 4.19.2, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 31187
North Unisex Restroom In School Age Room 2
Lavatory
The knee clearance space under the lavatory designated to be
accessible in the restroom is less than the required minimum for
the primary age group.
Finding 23.75 inches
Code At least 24.00 inches
ADA 4.19.2, CA 11B-606.2
einstall or replace the lavatory designated to be accessible
ith an accessible lavatory that provides the required knee
earance for the primary age group.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 634 of 853
Record Number 31188
North Unisex Restroom In School Age Room 2
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 12.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
(stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
esolution Not Set
_:rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 31189
North Unisex Restroom In School Age Room 2
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
lsulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
abrasive surfaces under the lavatory.
riority Not Set
esolution Not Set
rogress Not Set
ssignment Not Set
$149
$0.00
Record Number 31190
North Unisex Restroom In School Age Room 2
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
riority Not Set
esolution Not Set
rogress Not Set
assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 635 of 853
Record Number 31184
North Unisex Restroom In School Age Room 2
Soap
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 39.50 inches
Code Up to 36.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
elocate the dispenser in the restroom to meet the required
eight for the primary age group.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 31185
North Unisex Restroom In School Age Room 2
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
ld does not require tight grasping, pinching, or twisting of the
rist.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 31193
South Unisex Restroom In School Age Room 2
There are grab bars missing from the toilet compartment.
Finding None Found
ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3
Install the required compliant grab bars in the toilet
compartment.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 636 of 853
Record Number 31194
South Unisex Restroom In School Age Room 2
The height of the toilet seat in the restroom is greater than the
allowed maximum height for use by the primary age group.
Finding 15.50 inches
Code 15.00 inches
ADA 4.16.7(3), CA 11B-604.9.3
djust or modify the height of the toilet seat in the restroom to
le required height for use by the primary age group.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 31195
South Unisex Restroom In School Age Room 2
The distance from the center line of the toilet to the nearest side
wall in the restroom is not at the required distance.
Finding 17.75 inches on center
Code 15.00 inches on center
ADA 4.16.7(1), CA 11B-604.9.1
elocate the toilet to provide a distance from the center line of
le toilet to the nearest side that meets the required distance
)r use by the primary age group.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,143
$0.00
Record Number 31197
South Unisex Restroom In School Age Room 2
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
Relocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$127
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 637 of 853
Record Number 31198
South Unisex Restroom In School Age Room 2
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 20.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 31199
South Unisex Restroom In School Age Room 2
There is less than the required minimum space in front of the
toilet.
Finding 32.50 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$3,500
$0.00
Record Number 31202
Boys Restroom In the Kindergarten Room
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 638 of 853
Record Number 31203
Boys Restroom In the Kindergarten Room
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 40.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 31204
Boys Restroom In the Kindergarten Room
The entrance door swings into the turning space within the
restroom.
Finding 8.50 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
Reverse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$8,200
$0.00
Record Number 31208
Boys Restroom In the Kindergarten Room
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 13.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
Replace or remount lavatory to meet the minimum required
distance to the center line of the fixture, when located adjacent
to a side wall or partition.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 639 of 853
Record Number 31209
Boys Restroom In the Kindergarten Room
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 47.00 inches
Code At least 48.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
elocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,261
$0.00
Record Number 31210
Boys Restroom In the Kindergarten Room
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
'riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 31211
Boys Restroom In the Kindergarten Room
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 640 of 853
Record Number 31207
Boys Restroom In the Kindergarten Room
Lavatory
The height of the counter surface of the lavatory designated to be
accessible in the restroom is greater than the allowed maximum
height for the primary age group.
Finding 30.50 inches
Code Up to 24.00 inches
ADA 4.19.2, CA 11B-604.9
aise or replace the lavatory to provide the minimum required
lee clearance.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 31213
Boys Restroom In the Kindergarten Room
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 31212
Boys Restroom In the Kindergarten Room
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 67.00 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
. equired height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 641 of 853
Record Number 31205
Boys Restroom In the Kindergarten Room
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
-id does not require tight grasping, pinching, or twisting of the
rist.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 31206
Boys Restroom In the Kindergarten Room
Soap
The height of the controls and operating mechanisms for the
dispenser in the restroom is not compliant for the primary age
group.
Finding 39.50 inches
Code Up to 32.00 inches
ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9
elocate the dispenser in the restroom to meet the required
eight for the primary age group.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 31223
Unisex Restroom In Classroom 2
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
Install a compliant privacy lock with occupancy indicator to the
door.
riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$804
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 642 of 853
Record Number 31225
Unisex Restroom In Classroom 2
Lavatory
The lavatory is in an enclosed cabinet, thereby preventing an
accessible forward approach.
Finding Not Accessible
ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306
emove or modify the lavatory cabinet and provide a compliant
vatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 31226
Unisex Restroom In Classroom 2
Lavatory
The knee clearance space under the lavatory designated to be
accessible in the restroom is less than the required minimum for
the primary age group.
Finding 17.00 inches
Code At least 19.00 inches
ADA 4.19.2, CA 11B-604.9
°einstall or replace the lavatory designated to be accessible
ith an accessible lavatory that provides the required knee
earance for the primary age group.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,286
$0.00
Record Number 31227
Unisex Restroom In Classroom 2
Lavatory
There is not sufficient clear floor space provided to allow ar,
accessible forward approach.
Finding 27.00 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
Relocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,261
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 643 of 853
Record Number 31228
Unisex Restroom In Classroom 2
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 31229
Unisex Restroom In Classroom 2
Lavatory
There is not enough toe clearance at the restroom lavatory.
Finding 3.50 inches
Code At least 9.00 inches
ADA 4.19.2
Provide minimum required toe clearance.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$289
$0.00
Record Number 31231
Unisex Restroom In Classroom 2
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 644 of 853
Record Number 31230
Unisex Restroom In Classroom 2
Male
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Record Number 31224
Unisex Restroom In Classroom 2
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding Not Accessible
ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
riority Not Set
.esolution Not Set
'rogress Not Set
.assignment Not Set
$277
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30975
Drinking Fountain In The Courtyard
There is less than the required minimum knee clearance height.
Finding 22.50 inches
Code At least 24.00 inches
ADA 4.15.5, CA 11B-604.9
rovide a fountain with the required knee and toe clearances.
riority Not Set
.esolution Not Set
rogress Not Set
.assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 645 of 853
Record Number 30974
Drinking Fountain In The Courtyard
The toe clearance is less than required.
Finding 7.50 inches
Code At least 9.00 inches
ADA 4.15.5, CA 11B-602.2, CA 11B-305
rovide a fountain with the required knee and toe clearances.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30976
Drinking Fountain In The Courtyard
The height of the water stream is less than required.
Finding 0.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
Hdjust the flow of the water stream to a compliant height.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 30977
Drinking Fountain In The Courtyard
The drinking fountain is not set entirely in an alcove.
Finding None Found
CA 11B-602.9
rovide compliant wing walls or barrier at the drinking fountain.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$640
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 646 of 853
Record Number 30973
Drinking Fountain In The Courtyard
eplace the drinking fountain with a compliant High/Low
)untain.
$2,500
$0.00
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
Play Area
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 31005
Kids Play Area
Slide - Fibar
The slope on the route to the transfer platform/play equipment is
not compliant.
Finding 99.00 percent
Code Up to 6.37 percent
Modify the slope of the route to transfer platform/play
equipment.
riority Not Set
.esolution Not Set
'rogress Not Set
ssignment Not Set
$26
$0.00
Record Number 31006
Kids Play Area
Slide - Fibar
The vertical clearance height on route to the transfer platform/play
equipment is not compliant.
Finding 0.00 inches
Code At least 80.00 inches
Provide compliant vertical clearance.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 647 of 853
Record Number 31007
Kids Play Area
Play Area Ground Equipment - Concrete/Solid Surface
The surface beneath the play area is non -accessible to individuals
with mobility impairments.
Finding Not Accessible
ADA 15.6
he play area should be made an accessible play area for the
icility. Provide a maneuvering space with an accessible
?silient surface beneath the play components and adjacent to
le play components where technically feasible.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$500
$0.00
Record Number 31008
Kids Play Area
Play Area Ground Equipment - Concrete/Solid Surface
Clear floor space at the ground level equipment is not compliant.
Finding 0.00 inches
Code At least 30.00 inches
rovide compliant clear floor space at the ground level
auipment.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,840
$0.00
Record Number 31009
Kids Play Area
Play Area Ground Equipment - Concrete/Solid Surface
The clear floor space at the ground level equipment is not firm and
stable.
Finding See Above
rovide compliant clear floor space at the ground level
auipment.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 648 of 853
Record Number 31010
Kids Play Area
Play Area Ground Equipment - Wood Chips
The surface beneath the play area is non -accessible to individuals
with mobility impairments.
Finding Not Accessible
ADA 15.6
he play area should be made an accessible play area for the
icility. Provide a maneuvering space with an accessible
?silient surface beneath the play components and adjacent to
le play components where technically feasible.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$500
$0.00
Record Number 31011
Kids Play Area
Play Area Ground Equipment - Wood Chips
The slope on the route to the transfer platform/play equipment is
not compliant.
Finding 99.00 percent
Code Up to 6.37 percent
odify the slope of the route to transfer platform/play
auipment.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$26
$0.00
Record Number 31012
Kids Play Area
Play Area Ground Equipment - Wood Chips
The clear floor space at the ground level equipment is not firrr
stable.
Finding See Above
provide compliant clear floor space at the ground level
auipment.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 649 of 853
Record Number 31013
Kids Play Area
Play Area Ground Equipment - Fibar
The clear floor space at the ground level equipment is not firm and
stable.
Finding See Above
rovide compliant clear floor space at the ground level
auipment.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,840
$0.00
Record Number 31014
Kids Play Area
Play Area Ground Equipment - Fibar
The clear floor space at the ground level equipment is not firm and
stable.
Finding See Above
°rovide compliant clear floor space at the ground level
auipment.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,840
$0.00
Record Number 31016
Kids Play Area
Play Area Ground Equipment - Fibar
The vertical clearance height on route to the transfer platform/play
equipment is not compliant.
Finding 45.00 inches
Code At least 80.00 inches
Provide compliant vertical clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 650 of 853
Record Number 31015
Kids Play Area
Play Area Ground Equipment - Fibar
The clear floor space at the ground level equipment is not firm and
stable.
Finding See Above
rovide compliant clear floor space at the ground level
auipment.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,840
$0.00
Record Number 31017
Kids Play Area
Play Area Ground Equipment - Fibar
The clear floor space at the ground level equipment is not firm and
stable.
Finding See Above
°rovide compliant clear floor space at the ground level
auipment.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,840
$0.00
Record Number 31018
Kids Play Area
Play Area Ground Equipment - Concrete/Solid Surface
The surface beneath the play area is non -accessible to individuals
with mobility impairments.
Finding Not Accessible
ADA 15.6
The play area should be made an accessible play area for the
facility. Provide a maneuvering space with an accessible
resilient surface beneath the play components and adjacent to
the play components where technically feasible.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 651 of 853
Record Number 31019
rovide compliant clear floor space at the ground level
auipment.
$1,840
$0.00
Kids Play Area
Play Area Ground Equipment - Concrete/Solid Surface
The clear floor space at the ground level equipment is not firm and
stable.
Finding See Above
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Record Number 31020
Kids Play Area
Play Area Ground Equipment - Concrete/Solid Surface
The seat height is not compliant.
Finding 25.00 inches
Code 11.00 - 24.00 inches
°rovide a compliant seat.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$445
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30817
Unisex Staff Restroom
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
0 700
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 652 of 853
Record Number 30832
YMCA Daycare Center
Ince visual warning devices are provided in all areas of the
icility, no additional action is required.
$0.00
There are visual warning devices provided throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 31101
Conference Room
The table knee depth does not meet required standards.
Finding 17.00 inches
Code At least 19.00 inches
ADA 4.27, CA 11B-306, CA 11B-902
provide compliant tables.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$2,174
$0.00
Record Number 31102
Conference Room
The table knee width does not meet required standards.
Finding 23.00 inches
Code At least 30.00 inches
ADA 4.27
"rovide compliant tables.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$2,174
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 653 of 853
Record Number 31103
Conference Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 30837
Sink In Kitchen
Sink counter height is not compliant.
Finding 35.75 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
provide compliant sink.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$1,800
$0.00
Record Number 30838
Sink In Kitchen
Sink knee clearance does not meet the standards.
Finding 25.75 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
"rovide compliant sink.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 654 of 853
Record Number 30839
Sink In Kitchen
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 30840
Sink In Kitchen
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 30841
Sink In Kitchen
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 655 of 853
Record Number 30842
Sink In Kitchen
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 44.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$180
$0.00
Record Number 30843
Sink In Kitchen
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 47.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$180
$0.00
Record Number 30844
Sink In Kitchen
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
Replace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$980
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 656 of 853
Record Number 30865
Sink In Pre -School Room 3
Sink counter height is not compliant.
Finding 35.50 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 30866
Sink In Pre -School Room 3
Sink knee clearance does not meet the standards.
Finding 26.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 30867
Sink In Pre -School Room 3
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
Make sure there is no toe kick at the sink.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$420
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 657 of 853
Record Number 30868
Sink In Pre -School Room 3
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
aainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 30869
Sink In Pre -School Room 3
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$190
$0.00
Record Number 30870
Sink In Pre -School Room 3
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 48.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
esolution Not Set
'rogress Not Set
_assignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 658 of 853
Record Number 30871
Sink In Pre -School Room 3
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
ld does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$980
$0.00
Record Number 30872
Sink In Pre -School Room 3
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$180
$0.00
Record Number 30927
Sink In Classroom 1
Sink knee clearance does not meet the standards.
Finding 25.75 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
Provide compliant sink.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 659 of 853
Record Number 30929
Sink In Classroom 1
There is not enough clear floor space at the sink.
Finding 27.00 inches
Code At least 30.00 inches
ADA 4.27
rovide enough clear floor space at the location.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 30928
Sink In Classroom 1
There is not enough toe clearance at the sink.
Finding 8.00 inches
Code At least 9.00 inches
ADA 4.27
rovide minimum required toe clearance.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 30930
Sink In Classroom 1
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 660 of 853
Record Number 30931
Sink In Classroom 1
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
ld does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$980
$0.00
Record Number 30932
Sink In Classroom 1
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$180
$0.00
Record Number 31021
Sink In School Age Room 2
Sink knee clearance does not meet the standards.
Finding 25.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
Provide compliant sink.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 661 of 853
Record Number 31022
Sink In School Age Room 2
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 31023
Sink In School Age Room 2
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 31024
Sink In School Age Room 2
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 662 of 853
Record Number 31025
Sink In School Age Room 2
There is not enough clear floor space at the sink.
Finding 21.00 inches
Code At least 30.00 inches
ADA 4.27
,ovide enough clear floor space at the location.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 31026
Sink In School Age Room 2
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$180
$0.00
Record Number 31027
Sink In School Age Room 2
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
Replace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$980
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 663 of 853
Record Number 31042
Sink In Pre -School Room 2
Sink counter height is not compliant.
Finding 35.25 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31043
Sink In Pre -School Room 2
Sink knee clearance does not meet the standards.
Finding 26.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31044
Sink In Pre -School Room 2
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
Make sure there is no toe kick at the sink.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$420
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 664 of 853
Record Number 31045
Sink In Pre -School Room 2
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
aainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 31046
Sink In Pre -School Room 2
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$190
$0.00
Record Number 31047
Sink In Pre -School Room 2
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 665 of 853
Record Number 31048
Sink In Pre -School Room 2
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
ld does not require tight grasping, pinching, or twisting of the
rist.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$980
$0.00
Record Number 31049
Sink In Pre -School Room 2
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$180
$0.00
Record Number 31062
Sink In Classroom 2
Sink knee clearance does not meet the standards.
Finding 26.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
Provide compliant sink.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 666 of 853
Record Number 31064
Sink In Classroom 2
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 31063
Sink In Classroom 2
There is not enough toe clearance at the sink.
Finding 6.00 inches
Code At least 9.00 inches
ADA 4.27
rovide minimum required toe clearance.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 31066
Sink In Classroom 2
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$980
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 667 of 853
Record Number 31065
Sink In Classroom 2
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$180
$0.00
Record Number 31067
Sink In Classroom 2
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 41.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$180
$0.00
Record Number 31092
Sink In Kindergarten Room
Sink counter height is not compliant.
Finding 35.50 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
Provide compliant sink.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 668 of 853
Record Number 31093
Sink In Kindergarten Room
Sink knee clearance does not meet the standards.
Finding 26.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31094
Sink In Kindergarten Room
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 31095
Sink In Kindergarten Room
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 669 of 853
Record Number 31096
Sink In Kindergarten Room
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$190
$0.00
Record Number 31097
Sink In Kindergarten Room
There is not enough clear floor space at the sink.
Finding 27.00 inches
Code At least 30.00 inches
ADA 4.27
rovide enough clear floor space at the location.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 31098
Sink In Kindergarten Room
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 670 of 853
Record Number 31099
Sink In Kindergarten Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 47.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$180
$0.00
Record Number 31100
Sink In Kindergarten Room
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
Replace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
'riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$980
$0.00
Record Number 31153
Sink In School Age Room 1
Sink knee clearance does not meet the standards.
Finding 25.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
rovide compliant sink.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 671 of 853
Record Number 31154
Sink In School Age Room 1
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
ake sure there is no toe kick at the sink.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 31155
Sink In School Age Room 1
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
3ainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 31156
Sink In School Age Room 1
The cabinet door hardware is not accessible.
Finding None Found
CA 11B-309
rovide compliant hardware for cabinet door.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 672 of 853
Record Number 31157
Sink In School Age Room 1
There is not enough clear floor space at the sink.
Finding 21.00 inches
Code At least 30.00 inches
ADA 4.27
rovide enough clear floor space at the location.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 31158
Sink In School Age Room 1
Paper Towel
The operable parts of the dispenser require tight grasping,
pinching, or twisting of the wrist.
Finding None Found
ADA 4.27.4, CA 11B-309.4
eplace dispenser with one that allows operation with one hand
id does not require tight grasping, pinching, or twisting of the
rist.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$980
$0.00
Record Number 31159
Sink In School Age Room 1
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 673 of 853
Record Number 31240
Sink In The Laundry Room
Sink counter height is not compliant.
Finding 36.00 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31241
Sink In The Laundry Room
Sink knee clearance does not meet the standards.
Finding 25.00 inches
Code At least 27.00 inches
ADA 4.27, CA 11B-606.2, CA 11B-306.3
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 31242
Sink In The Laundry Room
The toe kick for the sink is not removed.
Finding Toe Kick Exists
CA 11B-606.2, CA 11B-305, CA 11B-306
Make sure there is no toe kick at the sink.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$420
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 674 of 853
Record Number 31243
Sink In The Laundry Room
There is not enough clear floor space at the sink.
Finding 45.00 inches
Code At least 48.00 inches
CA 11B-606.2
rovide enough clear floor space at the location.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 31146
Picnic Tables In The Courtyard
The required percentage of picnic tables provided are not
accessible.
Finding None Found
Code At least 1.00 tables
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
rovide a sufficient number of compliant picnic tables.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 675 of 853
New Fire Station (Fire Station #32)
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46429
Accessible Parking
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$250
$0.00
Record Number 46431
Accessible Parking
Right Accessible Space Next To Corporation Yard
There is no signage posted at the accessible parking space
showing the International Symbol of Accessibility.
Finding None Found
ADA 4.6.4, CA 11B-502.6, CA 11B-703.7.2.1
rovide compliant sigange at the accessible space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$250
$0.00
Record Number 46430
Accessible Parking
Right Accessible Space Next To Corporation Yard
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
e-stripe the existing parking space marked as accessible to
efine the width of the space.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 676 of 853
Record Number 46432
Accessible Parking
Right Accessible Space Next To Corporation Yard
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$300
$0.00
Record Number 46433
Accessible Parking
Left Accessible Space Next To Corporation Yard
The accessible parking space does not meet the minimum
requirements for width.
Finding 91.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$350
$0.00
Record Number 46434
Accessible Parking
Left Accessible Space Next To Corporation Yard
There is no signage posted at the accessible parking space
showing the International Symbol of Accessibility.
Finding None Found
ADA 4.6.4, CA 11B-502.6, CA 11B-703.7.2.1
Provide compliant sigange at the accessible space.
tiority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 677 of 853
Record Number 46435
Accessible Parking
Left Accessible Space Next To Corporation Yard
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$300
$0.00
Record Number 46436
Accessible Parking
Left Accessible Space Next To Corporation Yard
The access aisle does not meet the minimum required width.
Finding 92.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
e-stripe the access aisle.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 46437
Accessible Parking
Right Accessible Space Next To The Main Entrance
The accessible parking space does not meet the minimum
requirements for width.
Finding 102.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
Re -stripe the accessible parking space.
tiority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 678 of 853
Record Number 46438
Accessible Parking
Right Accessible Space Next To The Main Entrance
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
tiority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$300
$0.00
Record Number 46439
Accessible Parking
Left Accessible Space Next To The Main Entrance
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
e-stripe the existing parking space marked as accessible to
fine the width of the space.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$350
$0.00
Record Number 46440
Accessible Parking
Left Accessible Space Next To The Main Entrance
The access aisle does not meet the minimum required width.
Finding 91.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
e-stripe the access aisle.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$250
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 679 of 853
Record Number 46442
Main Entrance Next To Reception
The clear opening width of the door is less than required.
Finding 30.58 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 46444
Unisex Restroom Next To IT Room
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 4.75 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 46443
Unisex Restroom Next To IT Room
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
quirements.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$25
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 680 of 853
Record Number 46450
Directional Signage From The Public Right Of Way
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 46445
Main Entrance Next To Reception Exit
The accessible entrance signage attached to the wall is not at the
required location.
Finding Mount Location Incorrect
ADA 4.30.6, CA 11B-703.4.2
rovide compliant signage identifying the accessible entrance on
le wall adjacent to the latch side of the doorway, mounted at
le required height and location.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$50
$0.00
Record Number 46446
Door From Main Entrance Lobby To Hallway
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
Install compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 681 of 853
Record Number 46448
Main Entrance Next To Reception
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 46449
Directional Signage To All Common Areas
There is no informational signage.
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall informational signage to each accessible element or room
location.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46420
Unisex Restroom Next To IT Room
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 44.50 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
' ower the mirror so the bottom edge of the reflective surface is
3 higher than recommended above the finished floor.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 682 of 853
Record Number 46418
Unisex Restroom Next To IT Room
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 46419
Unisex Restroom Next To IT Room
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 46421
Unisex Restroom Next To IT Room
There is no signage with the International Symbol of Accessibility.
Finding None Found
ADA 4.30.4, CA 11B-703.7
Tnstall signage that includes the International Symbol of
Accessibility.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 683 of 853
Record Number 46427
Unisex Restroom Next To IT Room
The coat hook is not mounted at the correct height.
Finding 72.00 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
tiority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$50
$0.00
Record Number 46426
Unisex Restroom Next To IT Room
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 46428
Unisex Restroom Next To IT Room
The toilet paper dispenser is not mounted at the required height.
Finding 17.25 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 684 of 853
Record Number 46423
Unisex Restroom Next To IT Room
The height of the toilet seat is not at the required height.
Finding 16.00 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,707
$0.00
Record Number 46422
Unisex Restroom Next To IT Room
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 17.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 46425
Unisex Restroom Next To IT Room
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 29.50 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 685 of 853
Record Number 46417
Visual Alarms
There are some visual warning devices, though visual warning
devices are not located throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, classrooms and
eneral use rooms, accessible restrooms and other accessible
)oms.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$2,200
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 46447
Outdoor BBQ Area
BBQ Grill - Other
Element controls are non accessible.
Finding None Found
ADA 4.11, CA 11B-309.4
'rovide compliant controls for the element.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 46441
Laundry Room
Washer/Dryers - Other
Element controls are non accessible.
Finding None Found
ADA 4.11, CA 11B-309.4
^rovide compliant controls for the element.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 686 of 853
Police Substation
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29430
Parking Lot Off Avenida Navarro & 1 Space Off Avenida
Bermudas
The location of the accessible parking space is not located on the
shortest accessible route of travel to the facility for which it serves.
Finding Not on Path
ADAG 4.6.2, CA 11B-208.2
elocate the designated accessible parking space to the
iortest accessible route of travel to the facility for which it
rves.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$1,379
$0.00
Record Number 29434
Parking Lot Off Avenida Navarro & 1 Space Off Avenida
Bermudas
Parking Lot Warning Sign
The point of contact and telephone number for reclaiming towed
vehicles have been left blank.
Finding Sign not Filled
CA 11B-502.8.2
II in the blank spaces with the point of contact and telephone
umber for reclaiming towed vehicles.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 687 of 853
Record Number 29432
Parking Lot Off Avenida Navarro & 1 Space Off Avenida
Bermudas
Accessible Space
The access aisle does not meet the minimum required width.
Finding 93.00 inches
Code At least 96.00 inches
ADA 4.1.2(5)
e-stripe the access aisle.
riority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$250
$0.00
Record Number 29433
Parking Lot Off Avenida Navarro & 1 Space Off Avenida
Bermudas
Accessible Space
The access aisle markings are faded, damaged, or otherwise not
viewable.
Finding None Found
CA 11B-502.3
Re -stripe the access aisle so as to discourage parking.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 29431
Parking Lot Off Avenida Navarro & 1 Space Off Avenida
Bermudas
Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 38.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Dace.
riority Not Set
esolution Not Set
'regress Not Set
ssignment Not Set
$220
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 688 of 853
Record Number 28570
Path Of Travel From The Public Right Of Way Off Avenida
Bermudas
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 5.30 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$3,600
$0.00
Record Number 28580
Path Of Travel From The Public Right Of Way Off Avenida
Navarro
Path Of Travel From The Public Right Of Way
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
-'rovide detectable warnings.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$190
$0.00
Record Number 28581
Path Of Travel From The Public Right Of Way Off Avenida
Navarro
Path Of Travel From The Public Right Of Way
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
Provide a compliant crosswalk.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,100
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 689 of 853
Record Number 28586
Gate From Parking Lot To Walkway To Avenida Bermudas
The clear opening width of the gate is not compliant.
Finding 52.00 inches
Code Up to 48.00 inches
rovide a compliant gate at the location.
tiority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 28391
Traffic Office
The clear opening width of the door is less than required.
Finding 27.00 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 28392
Traffic Office
The vertical clearance height of the door is less than required.
Finding 77.50 inches
Code At least 78.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
)(tend the height of the doorway to provide the required
earance height.
tiority Not Set
esolution Not Set
'rogress Not Set
.,ssignment Not Set
$2,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 690 of 853
Record Number 28394
Traffic Office
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 39.50 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
tiority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 28393
Traffic Office
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
°rovide accessible hardware on the door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28412
Unisex Restroom
The clear opening width of the door is less than required.
Finding 25.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
'^liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 691 of 853
Record Number 28413
Unisex Restroom
The vertical clearance height of the door is less than required.
Finding 77.50 inches
Code At least 78.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
tend the height of the doorway to provide the required
earance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,000
$0.00
Record Number 28417
Unisex Restroom
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 35.00 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,000
$0.00
Record Number 28418
Unisex Restroom
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 55.50 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
'riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 692 of 853
Record Number 28416
Unisex Restroom
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 3.25 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 28414
Unisex Restroom
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
°rovide accessible hardware on the door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28415
Unisex Restroom
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
nrovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
tiority Not Set
.esolution Not Set
'rogress Not Set
_.ssignment Not Set
$310
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 693 of 853
Record Number 28464
Open Doorway In Office Hallway
The clear opening width of the doorway is not compliant.
Finding 30.25 inches
Code At least 32.00 inches
ADA 4.13.5
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,800
$0.00
Record Number 28463
Open Doorway In Office Hallway
The vertical clearance height of the open doorway is not
compliant.
Finding 78.50 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
tiority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$5,600
$0.00
Record Number 28508
Right Hallway Office
The clear opening width of the door is less than required.
Finding 27.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 694 of 853
Record Number 28510
Right Hallway Office
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28511
Right Hallway Office
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Record Number 28556
Open Doorway Between Reception & Office Hallway
The clear opening width of the doorway is not compliant.
Finding 28.25 inches
Code At least 32.00 inches
ADA 4.13.5
Eiden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 695 of 853
Record Number 28555
Open Doorway Between Reception & Office Hallway
The vertical clearance height of the open doorway is not
compliant.
Finding 78.00 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
tiority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$5,600
$0.00
Record Number 28583
Left Hallway Office
The clear opening width of the door is less than required.
Finding 27.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 28585
Left Hallway Office
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
Provide accessible hardware on the door.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 696 of 853
Record Number 28587
Main Entrance Off Avenida Bermudas
The vertical clearance height of the door is less than required.
Finding 77.00 inches
Code At least 78.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
tend the height of the doorway to provide the required
earance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,000
$0.00
Record Number 28590
Main Entrance Off Avenida Bermudas
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Record Number 28589
Main Entrance Off Avenida Bermudas
The bottom of the door does not provide a smooth, uninterrupted
surface to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.
Finding 7.50 inches
Code At least 10.00 inches
CA 11B-404.2.10
(stall a panel or replace the door to provide a smooth,
ninterrupted surface at the bottom of the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 697 of 853
Record Number 28588
Main Entrance Off Avenida Bermudas
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Not Set
esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28651
Door Between Reception Lobby & Picnic Area
The clear opening width of the door is less than required.
Finding 27.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
esolution Not Set
'regress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 28652
Door Between Reception Lobby & Picnic Area
The vertical clearance height of the door is less than required.
Finding 77.50 inches
Code At least 78.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
)(tend the height of the doorway to provide the required
earance height.
tiority Not Set
esolution Not Set
'regress Not Set
.,ssignment Not Set
$2,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 698 of 853
Record Number 28653
Door Between Reception Lobby & Picnic Area
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28654
Door Between Reception Lobby & Picnic Area
The height of the threshold at the entrance door is greater than
allowed.
Finding 3.25 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28499
Reception Counter
The height of the counter or desk does not comply with height
requirements.
Finding 42.25 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$3,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 699 of 853
Record Number 28500
Reception Counter
The counter is a protruding object.
Finding See Above
ADA 4.32.4, ADA 7.2
djust the counter so that it is no longer a protruding object.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$450
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28431
Gate From Parking Lot To Walkway To Avenida Bermudas
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
istall compliant room identification signage.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Record Number 28617
Directional Signage From The Public Right Of Way Off Avenida
Navarro
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
Install directional signage to each accessible element or room.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 700 of 853
Record Number 28656
Directional Signage From Parking Lot To Avenida Bermudas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28390
Open Doorway Between Reception & Office Hallway
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28395
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
(stall directional signage to each accessible element or room.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 701 of 853
Record Number 28406
Right Hallway Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28465
Open Doorway In Office Hallway
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28480
Door Between Reception Lobby & Picnic Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 702 of 853
Record Number 28558
Left Hallway Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28567
Traffic Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28573
Main Entrance Off Avenida Bermudas
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
install accessible room signage.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 703 of 853
Record Number 28423
Unisex Restroom
There are no grab bars.
Finding None Found
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5
(stall the required grab bars in the toilet compartment.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 28422
Unisex Restroom
The clearance around the water closet measured perpendicular
from the side wall is not compliant.
Finding 55.75 inches
Code At least 60.00 inches
ADA 4.16.2
rovide a compliant clearance around the water closet
ieasured perpendicular from the rear wall.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 28425
Unisex Restroom
The height of the toilet seat is not at the required height.
Finding 14.75 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
tiority Not Set
esolution Not Set
'rogress Not Set
.,ssignment Not Set
$1,707
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 704 of 853
Record Number 28424
Unisex Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 14.00 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
Priority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 28427
Unisex Restroom
The flush control on the toilet is not on the wide (approach) side
of the toilet.
Finding Wrong Side of Toilet
ADA 4.16.5, CA 11B-604.6
elocate the flush control so it is on the wide (approach) side of
le toilet area. Flush controls shall be hand -operated or
atomatic mechanisms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$127
$0.00
Record Number 28428
Unisex Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 13.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
the toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 705 of 853
Record Number 28429
Unisex Restroom
There is less than the required minimum space in front of the
toilet.
Finding 34.00 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
tiority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$3,500
$0.00
Record Number 28430
Unisex Restroom
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
stance from the front edge of the toilet seat.
tiority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$78
$0.00
Record Number 29437
Unisex Restroom
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
tiority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 706 of 853
Record Number 29436
Unisex Restroom
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
Priority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$804
$0.00
Record Number 29438
Unisex Restroom
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 42.50 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 29439
Unisex Restroom
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
Provide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 707 of 853
Record Number 29440
Unisex Restroom
The entrance door swings into the turning space within the
restroom.
Finding 27.50 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$8,200
$0.00
Record Number 29449
Unisex Restroom
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 51.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
I ower the mirror so the bottom edge of the reflective surface is
i to higher than recommended above the finished floor.
riority Not Set
.esolution Not Set
'rogress Not Set
_,ssignment Not Set
$300
$0.00
Record Number 29450
Unisex Restroom
The top of the mirror is not at the compliant height.
Finding 73.75 inches
Code At least 74.00 inches
ADA 4.19.6
Provide a compliant mirror in the restroom.
'riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 708 of 853
Record Number 29442
Unisex Restroom
Lavatory
The lavatory is in an enclosed cabinet, thereby preventing an
accessible forward approach.
Finding Not Accessible
ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306
emove or modify the lavatory cabinet and provide a compliant
vatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 29443
Unisex Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 23.62 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
Raise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,286
$0.00
Record Number 29444
Unisex Restroom
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 14.00 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
Replace or remount lavatory to meet the minimum required
'lstance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
.esolution Not Set
.rogress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 709 of 853
Record Number 29445
Unisex Restroom
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 22.25 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
elocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,261
$0.00
Record Number 29446
Unisex Restroom
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 42.50 inches
Code At least 48.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
Relocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,261
$0.00
Record Number 29447
Unisex Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
'riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 710 of 853
Record Number 29448
Unisex Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$149
$0.00
Record Number 29452
Unisex Restroom
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
Provide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$158
$0.00
Record Number 29451
Unisex Restroom
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
. equired height.
riority Not Set
.esolution Not Set
'regress Not Set
..ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 711 of 853
Record Number 29441
Unisex Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 53.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$277
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28571
Visual Alarms
There are no visual warning devices at the facility.
Finding None Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
Install visual warning devices integrated with the facility's alarm
system in all common areas.
Priority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,200
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28591
Picnic Table
No ISA Symbol was found at the picnic table.
Finding None Found
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
dd a compliant ISA symbol at the picnic table.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 712 of 853
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28410
Benches
The bench height is not compliant.
Finding 15.25 inches
Code 17.00 - 19.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench height to recommended value.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$800
$0.00
Record Number 28411
Benches
The bench back rest height is not compliant.
Finding 17.00 inches
Code At least 18.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench back rest height to recommended value.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$800
$0.00
Rooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 29435
Police Substation
The tub is not accessible.
Finding Not Designated
ADA 9.1
rovide a compliant accessible tub.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,765
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 713 of 853
Public Works & Maintenance
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28563
City Vehicle Parking Lot
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$250
$0.00
Record Number 28562
City Vehicle Parking Lot
The minimum number of accessible parking spaces are not
provided in the parking lot.
Finding None Found
ADA 4.1.2(5), CA 118-208.2, CA 118-502
e-stripe any existing parking spaces marked accessible and
-eate additional accessible parking spaces.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$370
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 714 of 853
Record Number 28615
rovide detectable warnings.
$190
$0.00
Path Of Travel From The Public Right Of Way Off Frances
Hack Lane
Path Of Travel From The Public Right Of Way
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Record Number 28616
Path Of Travel From The Public Right Of Way Off Frances
Hack Lane
Path Of Travel From The Public Right Of Way
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
rovide a compliant crosswalk.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,100
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28546
Stairs To Corporation Yard Office Building
Stairway is marked as primary access. There is no other means of
vertical access.
Finding No Access
ADA 4.3.11.3, CA 11B-206.2, CA 11B-210, CA 11B-402.2, CA 11B
-504
rovide a compliant means of vertical access.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$4,816
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 715 of 853
Record Number 28547
Stairs To Corporation Yard Office Building
Run 1
The width of the stairway does not meet the minimum required
width.
Finding 40.25 inches
Code At least 44.00 inches
ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504
(stall a stairway with a minimum width as required.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,816
$0.00
Record Number 28548
Stairs To Corporation Yard Office Building
Run 1
There is no handrail provided on one side of the stairway.
Finding None Found
ADA 4.9.4, CA 11B-504.6, CA 11B-505.2
Provide compliant handrails on the stairway.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,528
$0.00
Record Number 28549
Stairs To Corporation Yard Office Building
Run 1
The risers on the stairway are open.
Finding Not Closed
ADA 4.9.2, CA 11B-504.3
lose the riser openings on the stairway. Open risers are not
ermitted.
'riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$480
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 716 of 853
Record Number 28550
Stairs To Corporation Yard Office Building
Run 1
There is no detectable striping on the stairways.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
ffix compliant contrasting striping to the upper approach and
3ch tread that is the correct width and distance from the
Dsing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,000
$0.00
Record Number 28551
Stairs To Corporation Yard Office Building
Run 1 Right Handrail
The diameter of the handrail is not within the required range.
Finding 1.00 inches
Code 1.25 - 2.00 inches
ADA 4.26.2, CA 11B-505.7
°rovide a compliant handrail with a diameter within the required
Inge.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,320
$0.00
Record Number 28552
Stairs To Corporation Yard Office Building
Run 1 Right Handrail
There are no bottom handrail extensions provided.
Finding None Found
ADA 4.9.4(2), CA 11B-505.10.3
Install handrail extension to the bottom of the handrail that
Ktends beyond the bottom riser at least one tread depth.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,425
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 717 of 853
Record Number 28420
Conference Room
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
tiority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28421
Conference Room
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Record Number 28432
Corporation Yard Office Building Entrance
The door closing device limits the required headroom clearance.
Finding 78.26 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 718 of 853
Record Number 28436
Corporation Yard Office Building Entrance
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 2.50 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance for the door.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 28437
Corporation Yard Office Building Entrance
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 41.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
Provide the recommended clear floor space on the pull side of
'ie door.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 28435
Corporation Yard Office Building Entrance
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.12 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 719 of 853
Record Number 28434
Corporation Yard Office Building Entrance
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28466
Unisex Restroom In Corporation Yard Office Building
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28467
Unisex Restroom In Corporation Yard Office Building
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
ght grasping, pinching, or twisting of the wrist to operate.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 720 of 853
Record Number 28507
Door Between Conference Room & Office
Push Side
There is not enough clear floor space provided at the push side of
the door .
Finding 32.50 inches
Code At least 48.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended clear floor space on the push side of
le door.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 28505
Door Between Conference Room & Office
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
°rovide accessible hardware on the door.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28506
Door Between Conference Room & Office
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
provide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Not Set
esolution Not Set
'rogress Not Set
_.ssignment Not Set
$310
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 721 of 853
Record Number 28543
Break Room
The vertical clearance height of the open doorway is not
compliant.
Finding 79.75 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$5,600
$0.00
Record Number 28544
Left & Right Training Room Doors
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28545
Left & Right Training Room Doors
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
ght grasping, pinching, or twisting of the wrist to operate.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 722 of 853
Record Number 28648
4 Office Doors
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28649
4 Office Doors
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Record Number 28537
Gate From Frances Hack Lane To City Vehicle Parking Lot
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 723 of 853
Record Number 28564
Gate From Shared Fire Station Parking Lot To Corporation
Yard
Push Side
There is no level landing at this door.
Finding 2.50 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,500
$0.00
Record Number 28388
Open Doorway Between Reception Area & Locker Area
The clear opening width of the doorway is not compliant.
Finding 29.00 inches
Code At least 32.00 inches
ADA 4.13.5
Widen the door opening and install a door that provides at least
'ie minimum clear width with the door open 90 degrees.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,800
$0.00
Record Number 28387
Open Doorway Between Reception Area & Locker Area
The vertical clearance height of the open doorway is not
compliant.
Finding 79.00 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$5,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 724 of 853
Record Number 28443
Right Entrance
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 10.50 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 28442
Right Entrance
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"lodify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
.assignment Not Set
$436
$0.00
Record Number 28441
Right Entrance
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
provide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 725 of 853
Record Number 28451
Door Between Work Area & Bay
The clear opening width of the door is less than required.
Finding 28.00 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 28452
Door Between Work Area & Bay
The vertical clearance height of the door is less than required.
Finding 77.50 inches
Code At least 78.00 inches
ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3
tend the height of the doorway to provide the required
earance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,000
$0.00
Record Number 28455
Door Between Work Area & Bay
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 11.50 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 726 of 853
Record Number 28453
Door Between Work Area & Bay
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$800
$0.00
Record Number 28454
Door Between Work Area & Bay
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Record Number 28460
Door Between Picnic Area & Work Area
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 58.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$2,921
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 727 of 853
Record Number 28459
Door Between Picnic Area & Work Area
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 19.00 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance for the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 28458
Door Between Picnic Area & Work Area
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
Provide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28542
Door Between Picnic Area & Locker Area
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 9.62 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
Dor.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$4,000
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 728 of 853
Record Number 28541
Door Between Picnic Area & Locker Area
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Record Number 28539
Door Between Picnic Area & Locker Area
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28540
Door Between Picnic Area & Locker Area
Single Knob
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding Not Accessible
ADA 404.2.7, ADA 309.4
rovide a compliant door lock for the door that does not require
ght grasping, pinching, or twisting of the wrist to operate.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$310
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 729 of 853
Record Number 28554
Door Between Left Entrance & Reception Area
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 32.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 28553
Door Between Left Entrance & Reception Area
None
Door hardware is not mounted at the correct height.
Finding 24.00 inches
Code 30.00 - 44.00 inches
ADA 309.4, ADA 404.2.7, CA 11B-404.2.7
"fount the door hardware at the recommended height.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$280
$0.00
Record Number 28599
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The clear opening width of the door is less than required.
Finding 29.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
'^liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 730 of 853
Record Number 28647
Gate To Picnic Area
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 47.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 28645
Gate To Picnic Area
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
°rovide accessible hardware on the door.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28646
Gate To Picnic Area
Single Knob
The bottom of the door or gate does not provide a smooth surface
on the push side extending the full width of the door or gate.
Finding None Found
CA 11B-404.2
Install a smooth uninterrupted surface or panel on the push
de, extending the full width of the door or gate.
riority Not Set
.esolution Not Set
'rogress Not Set
_.ssignment Not Set
$400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 731 of 853
Record Number 28663
Left Entrance
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 8.00 inches
Code At least 18.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide required latch side clearance on the pull side of the
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$4,000
$0.00
Record Number 28661
Left Entrance
Single Knob
The door opening hardware is not accessible.
Finding Not Accessible
ADA 404.2.7, CA 11B-404.2.7
°rovide accessible hardware on the door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Record Number 28662
Left Entrance
The height of the threshold at the entrance door is greater than
allowed.
Finding 1.00 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
"^odify or replace the threshold to provide the recommended
eight.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 732 of 853
Record Number 28479
Reception Counter
The height of the counter or desk does not comply with height
requirements.
Finding 42.50 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
rovide a portion of counter at the compliant height.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$3,500
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28419
Corporation Yard Office Building Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
Tnstall accessible room signage.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Record Number 28502
Directional Signage To All Common Areas
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
Install directional signage to each accessible element or room.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 733 of 853
Record Number 28568
4 Office Doors
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28572
Break Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28575
Conference Room
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 734 of 853
Record Number 28618
Door Between Conference Room & Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28655
Left & Right Training Room Doors
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28389
Right Entrance
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 735 of 853
Record Number 28534
Left Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
lstall accessible room signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28559
Door Between Picnic Area & Locker Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28569
Gate To Picnic Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 736 of 853
Record Number 28576
Door Between Work Area & Bay
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28582
Open Doorway Between Reception Area & Locker Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
lstall compliant room identification signage.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28650
Door Between Picnic Area & Work Area
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
install compliant room identification signage.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 737 of 853
Record Number 28790
Unisex Restroom In Corporation Yard Office Building
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
(stall a compliant privacy lock with occupancy indicator to the
Dor.
Priority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$804
$0.00
Record Number 28791
Unisex Restroom In Corporation Yard Office Building
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.
Finding 55.00 inches
Code At least 60.00 inches
ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3
odify the restroom to provide sufficient clear floor space for a
irning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$14,000
$0.00
Record Number 28792
Unisex Restroom In Corporation Yard Office Building
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
Provide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 738 of 853
Record Number 28801
Unisex Restroom In Corporation Yard Office Building
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 47.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$300
$0.00
Record Number 28802
Unisex Restroom In Corporation Yard Office Building
The top of the mirror is not at the compliant height.
Finding 66.50 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 28800
Unisex Restroom In Corporation Yard Office Building
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
jrasive surfaces under the lavatory.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 739 of 853
Record Number 28795
Unisex Restroom In Corporation Yard Office Building
Lavatory
The lavatory is in an enclosed cabinet, thereby preventing an
accessible forward approach.
Finding Not Accessible
ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306
emove or modify the lavatory cabinet and provide a compliant
vatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$420
$0.00
Record Number 28796
Unisex Restroom In Corporation Yard Office Building
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 25.25 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
Raise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,286
$0.00
Record Number 28797
Unisex Restroom In Corporation Yard Office Building
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 12.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
Replace or remount lavatory to meet the minimum required
'lstance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
.esolution Not Set
.rogress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 740 of 853
Record Number 28798
Unisex Restroom In Corporation Yard Office Building
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 22.00 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
elocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,261
$0.00
Record Number 28799
Unisex Restroom In Corporation Yard Office Building
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
'riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 28803
Unisex Restroom In Corporation Yard Office Building
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
quired height.
'riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 741 of 853
Record Number 28804
Unisex Restroom In Corporation Yard Office Building
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Record Number 28793
Unisex Restroom In Corporation Yard Office Building
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 55.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 28794
Unisex Restroom In Corporation Yard Office Building
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 51.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
_assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 742 of 853
Record Number 28603
Unisex Restroom In Corporation Yard Office Building
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 28602
Unisex Restroom In Corporation Yard Office Building
There is no back grab bar at the toilet compartment.
Finding None Found
ADA 4.17.6, CA 11B-604.5, CA 11B-604.8.1.5
rnstall the required grab bars in the toilet compartment.
'riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 28601
Unisex Restroom In Corporation Yard Office Building
The location of the seat cover dispenser does not provide
sufficient clear floor space.
Finding Not Accessible
ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1
Relocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 743 of 853
Record Number 28608
Unisex Restroom In Corporation Yard Office Building
The length of the side grab bar is less than required.
Finding 36.00 inches
Code At least 42.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1
eplace the side grab bar with a compliant grab bar.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 28612
Unisex Restroom In Corporation Yard Office Building
The height of the side grab bar is not at the correct height.
Finding 31.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 28609
Unisex Restroom In Corporation Yard Office Building
The distance from the rear wall to the side grab bar is greater
than allowed.
Finding 16.00 inches
Code Up to 12.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1
emount the side grab bar so it meets the distance
?quirements from the back wall.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 744 of 853
Record Number 28610
Unisex Restroom In Corporation Yard Office Building
The distance from the back wall to the front of the grab bar is less
than required.
Finding 52.00 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 28611
Unisex Restroom In Corporation Yard Office Building
The distance from the front edge of the toilet to the front edge of
the side grab bar is insufficient.
Finding 21.00 inches
Code At least 24.00 inches
CA 11B-604.5.1
(stall or relocate the side grab bar so that the distance from
le front edge of the toilet to the front edge of the side grab
ar meets the required minimum distance.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 28604
Unisex Restroom In Corporation Yard Office Building
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 20.00 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'rogress Not Set
.-ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 745 of 853
Record Number 28606
Unisex Restroom In Corporation Yard Office Building
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 23.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 28607
Unisex Restroom In Corporation Yard Office Building
There is less than the required minimum space in front of the
toilet.
Finding 47.50 inches
Code At least 48.00 inches
ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1
reate the required minimum clear space in front of the toilet.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$3,500
$0.00
Record Number 28613
Unisex Restroom In Corporation Yard Office Building
The toilet paper dispenser interferes with the use of the grab bar.
Finding Interferes
ADA 4.16.6, CA 11B-309.4, CA 11B-609.3
elocate the toilet paper dispenser so it does not interfere with
le use of a grab bar. Toilet paper dispensers must allow
)ntinuous paper flow.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 746 of 853
Record Number 28773
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The entrance door swings inward at the restroom, thereby limiting
the minimum amount of clear floor space.
Finding Reduced CFS
ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4
odify the restroom to provide sufficient clear floor space for a
arning radius in the restroom to accommodate an individual in
wheelchair.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$1,800
$0.00
Record Number 28772
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The restroom door does not provide a compliant privacy lock with
occupancy indicator.
Finding None Found
CA 11B-213.2.1
Install a compliant privacy lock with occupancy indicator to the
' Dor.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$804
$0.00
Record Number 28774
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The door lock requires tight grasping, pinching, or twisting of the
wrist to operate.
Finding None Found
ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7
, CA 11B-309.4
Provide a compliant door lock for the door that does not require
aht grasping, pinching, or twisting of the wrist to operate.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$280
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 747 of 853
Record Number 28775
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The entrance door swings into the turning space within the
restroom.
Finding 40.00 inches
Code At least 48.00 inches
ADA 4.2.3, CA 11B-603.2.3
everse the door swing, or modify the restroom to provide
efficient clear floor space for a turning radius in the restroom
accommodate an individual in a wheelchair.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$8,200
$0.00
Record Number 28787
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The height of the urinal rim in the restroom is not compliant.
Finding 26.00 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
Lower the urinal designated to be accessible in the restroom so
'bat the rim height is compliant.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$1,397
$0.00
Record Number 28785
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 47.25 inches
Code Up to 40.00 inches
ADA 4.19.6, CA 11B-603.3
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 748 of 853
Record Number 28786
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The top of the mirror is not at the compliant height.
Finding 72.50 inches
Code At least 74.00 inches
ADA 4.19.6
rovide a compliant mirror in the restroom.
riority Not Set
.esolution Not Set
'regress Not Set
_,ssignment Not Set
$250
$0.00
Record Number 28784
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
There is not enough toe clearance at the restroom lavatory.
Finding 8.50 inches
Code At least 9.00 inches
ADA 4.19.2
rovide minimum required toe clearance.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$289
$0.00
Record Number 28778
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
The lavatory is in an enclosed cabinet, thereby preventing an
accessible forward approach.
Finding Not Accessible
ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306
Remove or modify the lavatory cabinet and provide a compliant
vatory.
'riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$420
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 749 of 853
Record Number 28779
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 25.25 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 28780
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
The lavatory center line does not meet the minimum required
distance when located adjacent to a side wall, partition or fixture.
Finding 12.50 inches on center
Code At least 18.00 inches on
center
CA 11B-606.6
eplace or remount lavatory to meet the minimum required
stance to the center line of the fixture, when located adjacent
a side wall or partition.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 28781
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
There is not sufficient clear floor space provided to allow an
accessible forward approach.
Finding 21.00 inches
Code At least 30.00 inches
ADA 4.19.3, CA 11B-606.2, CA 11B-305
-'elocate the lavatory to provide clear floor space.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,261
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 750 of 853
Record Number 28782
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 28783
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 28789
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
There is no compliant signage indicating accessibility on the latch
side of the entry door of the restroom.
Finding None Found
ADA 4.30.6, CA 11B-216.8
rovide compliant signage on latch side of door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 751 of 853
Record Number 28788
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
All Gender
There is no gender use signage on the entrance door.
Finding None Found
CA 11B-216.8, CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 28776
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 49.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
°elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$277
$0.00
Record Number 28777
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 53.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 752 of 853
Record Number 28592
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The height of the operable parts of the seat cover dispenser is
greater than the allowed maximum height.
Finding 43.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the seat cover dispenser to a compliant height, that
rovides sufficient clear floor space, and does not interfere with
se of the grab bars.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$277
$0.00
Record Number 28593
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
There are no grab bars.
Finding None Found
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5
Install the required grab bars in the toilet compartment.
tiority Not Set
.esolution Not Set
'rogress Not Set
.assignment Not Set
$267
$0.00
Record Number 28598
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The paper dispenser is located behind the front of toilet seat.
Finding See Above
ADA 4.2, CA 11B-604.7
emount the toilet paper dispenser so it is within the required
stance from the front edge of the toilet seat.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$78
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 753 of 853
Record Number 28595
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The height of the toilet seat is not at the required height.
Finding 16.00 inches
Code 17.00 - 19.00 inches
ADA 4.16.3, CA 11B-604.4
djust or modify the toilet so the seat height is at the required
:cessible height.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,707
$0.00
Record Number 28594
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 16.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 28597
Unisex Restroom In Public Works Department Streets & Parks
Building Next To Lockers
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 39.00 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
Provide a compliant amount of clearance from the center line of
the toilet to the nearest fixture or wall on the wide side.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 754 of 853
Record Number 28478
Visual Alarms
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas.
$2,200
$0.00
There are no visual warning devices at the facility.
Finding None Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28468
Break Room
A compliant path of travel width is not maintained throughout the
break/conference room.
Finding None Found
ADA 4.27
provide a compliant path of travel width throughout the
preak/conference room.
riority Not Set
esolution Not Set
rogress Not Set
..ssignment Not Set
$1,840
$0.00
Record Number 28469
Break Room
Sink counter height does not meet the standards.
Finding 35.75 inches
Code Up to 34.00 inches
CA 11B-606.3
"rovide compliant sink.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 755 of 853
Record Number 28470
Break Room
Sink knee clearance does not meet the standards.
Finding 20.00 inches
Code At least 27.00 inches
ADA 4.27
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 28471
Break Room
The toe kick for the sink in break/conference room is not removed.
Finding Not Removed
CA 11B-606.2, CA 11B-305, CA 11B-306
emove the toe kick for the sink.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$612
$0.00
Record Number 28472
Break Room
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
Ipes under the sink to protect against contact. Make certain
sere are no sharp or abrasive surfaces under the sink.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 756 of 853
Record Number 28473
Break Room
The cabinet door hardware is not accessible.
Finding None Found
ADA 4.27, CA 11B-606.4
rovide compliant hardware for the cabinet door.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,000
$0.00
Record Number 28474
Break Room
There is not enough clear floor space at the sink.
Finding 29.00 inches
Code At least 48.00 inches
ADA 4.27
rovide enough clear floor space at the location.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Record Number 28475
Break Room
There is not enough clear floor space at the sink.
Finding 29.50 inches
Code At least 30.00 inches
ADA 4.27
-ovide enough clear floor space at the location.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$900
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 757 of 853
Record Number 28476
Break Room
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
elocate the dispenser to the correct height.
riority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$110
$0.00
Record Number 28477
Break Room
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 55.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7
Relocate the dispenser to the correct height.
riority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$110
$0.00
Record Number 28642
Conference Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
Install an International Symbol of Accessibility at the table.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 758 of 853
Record Number 28444
rovide a sufficient number of compliant picnic tables.
$500
$0.00
Picnic Table In Public Works Department Streets & Parks
Building Picnic Area
The required percentage of picnic tables provided are not
accessible.
Finding None Found
Code At least 1.00 tables
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Lockers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 28512
Lockers
No accessible lockers were found.
Finding Not Available
CA 11B-225.2.1, CA 11B-811
rovide a compliant amount of accessible lockers.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$1,840
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Co
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 759 of 853
Record Number 28501
ontact the owner of the vending machines to obtain accessible
=nding machines.
$0.00
Public Works Department Streets & Parks Building Picnic Area
Coca-Cola Vending Machine
The forward reach height of the controls on the vending machine
is greater than the allowed maximum height.
Finding 50.00 inches
Code Up to 48.00 inches
ADA 4.2.5
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Record Number 28574
City Vehicle Parking Lot
Eye Washing Stations - Eye Washing Station
This element is a protruding object.
Finding None Found
ADA 4.2
"lake sure that the element is not a protruding object.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 760 of 853
Silver Rock Temporary Clubhouse
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44206
Parking Lot
The minimum number of accessible parking spaces are not
provided in the parking lot.
Finding 2.00 spaces
Code At least 5.00 spaces
ADA 4.1.2(5), CA 11B-208.2
e-stripe any existing parking spaces marked accessible and
-eate additional accessible parking spaces.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$370
$0.00
Record Number 44221
Parking Lot
Warning Sign
The point of contact and telephone number for reclaiming towed
vehicles have been left blank.
Finding Sign not Filled
CA 11B-502.8.2
II in the blank spaces with the point of contact and telephone
umber for reclaiming towed vehicles.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 44210
Parking Lot
Right Accessible Space
The bottom edge of the post -mounted signage designating the
accessible parking space is not at the required height.
Finding 63.00 inches
Code At least 80.00 inches
ADA 4.6.4, CA 11B-502.6
post signage at a compliant height.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 761 of 853
Record Number 44209
Parking Lot
Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 38.25 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$220
$0.00
Record Number 44207
Parking Lot
Right Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.60 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
°epave the accessible space to provide a compliant slope.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$3,800
$0.00
Record Number 44208
Parking Lot
Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
provide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 762 of 853
Record Number 44212
Parking Lot
Left Accessible Space
The slope of the accessible parking space is not compliant.
Finding 6.80 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
epave the accessible space to provide a compliant slope.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$3,800
$0.00
Record Number 44213
Parking Lot
Left Accessible Space
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
istall a wheel stop at the head of the accessible parking space.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 44214
Parking Lot
Left Accessible Space
The accessible parking space does not meet the minimum
requirement for length.
Finding 215.50 inches
Code At least 216.00 inches
CA 11B-502.2
e-stripe the accessible parking space.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$350
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 763 of 853
Record Number 44211
Parking Lot
Left Accessible Space
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
e-stripe the existing parking space marked as accessible to
fine the width of the space.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$350
$0.00
Record Number 44215
Parking Lot
Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
°rovide a minimum fine sign at the parking space below the
International Symbol of Accessibility.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$300
$0.00
Record Number 44216
Parking Lot
Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 38.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
provide compliant surface identification at the accessible parking
Dace.
riority Not Set
.esolution Not Set
'rogress Not Set
_.ssignment Not Set
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 764 of 853
Record Number 44217
Parking Lot
Left Accessible Space
The bottom edge of the post -mounted signage designating the
accessible parking space is not at the required height.
Finding 65.50 inches
Code At least 80.00 inches
ADA 4.6.4, CA 11B-502.6
Dst signage at a compliant height.
riority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$158
$0.00
Record Number 44219
Parking Lot
Left Accessible Space
The slope of the access aisle is not compliant.
Finding 3.40 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
Repave the access aisle to provide a compliant surface slope.
riority Not Set
esolution Not Set
'regress Not Set
Assignment Not Set
$3,800
$0.00
Record Number 44220
Parking Lot
Left Accessible Space
The hatched lines are striped a noncompliant distance on center.
Finding Not on 36" center
CA 11B-502.3.3
e-stripe the hatched lines in a contrasting color at a compliant
(stance on center.
'riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$350
$0.00
Passenger Loading Zones
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 765 of 853
Record Number 44154
Valet & Bag Drop
There is no required striped access aisle adjacent to the passenger
loading zone.
Finding None Found
ADA 4.6.6, CA 11B-503.3
tripe a compliant access aisle adjacent and parallel to the
=hicle pull-up space.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$650
$0.00
Record Number 44153
Valet & Bag Drop
There are curbs between the access aisle and the vehicle pull-up
space.
Finding Curbs Exists
ADA 4.6.6, CA 11B-503.4, CA 11B-206.2.1, CA 11B-303.4
rovide compliant curb ramp to provide access from the
assenger loading zone.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$150
$0.00
Record Number 44155
Valet & Bag Drop
There is no signage designating accessibility posted at the
passenger loading zone.
Finding None Found
ADA 4.1.2(7)(b), ADA 4.6.6
Dst compliant signage designating the passenger loading zone
3 accessible.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$400
$0.00
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 766 of 853
Record Number 44176
Curb Ramp East Of The Clubhouse
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
_,ssignment Not Set
$248
$0.00
Record Number 44177
Curb Ramp East Of The Clubhouse
The cross slope is greater than allowed.
Finding 4.20 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.7
rovide a compliant curb ramp.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,300
$0.00
Record Number 44178
Curb Ramp East Of The Clubhouse
The slope of the curb ramp right side flare is greater than allowed.
Finding 11.00 percent
Code Up to 10.00 percent
ADA 4.7.5, CA 11B-406.2.2
rovide curb ramp side flares with a compliant slope.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 767 of 853
Record Number 44179
Curb Ramp East Of The Clubhouse
Top Landing
There is not enough top landing clear length.
Finding 0.00 inches
Code At least 48.00 inches
ADA 4.7, CA 11B-406.5.3
rovide a level top landing with enough clear length.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$240
$0.00
Record Number 44268
Curb Ramp From The Accessible Spaces
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
assignment Not Set
$248
$0.00
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44114
Path Of Travel To The Clubhouse Restrooms
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 12.30 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
"rovide a compliant path of travel.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 768 of 853
Record Number 44115
Path Of Travel To The First Hole
Exterior Walkway
The path of travel is grass, dirt, or gravel, preventing access to
individuals with mobility impairments.
Finding Dirt, Grass or Gravel
ADA 4.5.1, CA 11B-302.1, CA 11B-403.2
rovide an accessible route.
riority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$1,840
$0.00
Record Number 44116
Path Of Travel From The Public Right Of Way
There is no compliant accessible route from the public right of way
to the accessible entrance of the facility.
Finding None Found
ADA 4.3.2
Provide an accessible route from the public right of way to the
--cility. Post compliant directional signage indicating the
:cessible route to the facility at every major junction along the
accessible route.
riority Not Set
esolution Not Set
'regress Not Set
.,ssignment Not Set
$1,840
$0.00
Record Number 44164
Floor Mats Around The Golf Shop & Grill Room
6 Floor Mats
The mats or carpet runners do not adhere to the underlying floor
surface and slip, thereby creating a hazardous path of travel.
Finding Not Accessible
ADA 4.5.3, CA 11B-403.2, CA 11B-302
Securely fasten the mats or carpet runners or replace with a
iat or carpet runner that grips to the underlying floor surface
provide a firm, stable, and slip resistant path of travel.
riority Not Set
esolution Not Set
'regress Not Set
Assignment Not Set
$42
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 769 of 853
Record Number 44175
Path Of Travel From The Valet & Bag Drop To The Clubhouse
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 6.50 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
tiority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$3,600
$0.00
Record Number 44182
Path Of Travel From The Storage To The Clubhouse
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 10.20 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
Provide a compliant path of travel.
tiority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$3,600
$0.00
Record Number 44183
Path Of Travel From The Storage To The Clubhouse
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 3.60 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
Provide a compliant path of travel.
tiority Not Set
esolution Not Set
'regress Not Set
_assignment Not Set
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 770 of 853
Record Number 44202
Path Of Travel To The Main Entrances
Vertical Hazard
The vertical clearance height is less than required.
Finding 79.25 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-307.4
rovide recommended vertical clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$108
$0.00
Record Number 44273
Path Of Travel From Golf Cart Trail To The Driving Range
Exterior Walkway
The path of travel is grass, dirt, or gravel, preventing access to
individuals with mobility impairments.
Finding Dirt, Grass or Gravel
ADA 4.5.1, CA 11B-302.1, CA 11B-403.2
rovide an accessible route.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,840
$0.00
Record Number 44285
Path Of Travel Near The Outside Dining Area
Lights
The leading edge of the item protrudes into the circulation route
greater than permitted.
Finding 14.75 inches
Code Up to 4.00 inches
ADA 4.4, CA 11B-307.2
Install side extensions, modify, relocate, or lower the item so
'at it is not a protruding object into the circulation route.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$640
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 771 of 853
Record Number 44295
Path Of Travel Around The Valet & Bag Drop
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 9.10 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$3,600
$0.00
Record Number 44296
Path Of Travel Around The Valet & Bag Drop
Exterior Walkway
There are cross slopes greater than allowed on the primary path
of travel.
Finding 2.70 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-403.3
Provide a compliant path of travel.
riority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$3,600
$0.00
Record Number 44297
Path Of Travel From The Accessible Spaces
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 7.30 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
Provide a compliant path of travel.
riority Not Set
.esolution Not Set
'regress Not Set
_assignment Not Set
$3,600
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 772 of 853
Record Number 44247
Path Of Travel To Tee Five Restrooms
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 5.60 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
rovide a compliant path of travel.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$3,600
$0.00
Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44168
Ramp To The Clubhouse
Run 1
The slope of the ramp is greater than the allowed slope.
Finding 9.20 percent
Code Up to 8.33 percent
ADA 4.8.2, CA 11B-405.2
Modify the run of the ramp to provide the required slope and
cross slope.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$3,600
$0.00
Record Number 44169
Ramp To The Clubhouse
Run 1 Top Landing
There is a change in elevation greater than allowed on the primary
path of travel of the ramp that is not beveled.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.3.8, ADA 4.5.2, CA 11B-303, CA 11B-405
Revel the area or resurface the area to provide a smooth and
vel path of travel.
riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 773 of 853
Record Number 44170
Ramp To The Clubhouse
Run 1 Bottom Landing
The slope of the landing is greater than required.
Finding 6.30 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-405.7.1
odify the landing to create a slope in any direction not
Kceeding the required maximum value.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,872
$0.00
Record Number 44171
Ramp To The Clubhouse
Run 1 Right Handrail
The handrail extension is not parallel to the floor or ground
surface.
Finding Not Parallel
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,400
$0.00
Record Number 44172
Ramp To The Clubhouse
Run 1 Right Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
Finding 8.00 inches
Code At least 12.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,400
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 774 of 853
Record Number 44173
Ramp To The Clubhouse
Run 1 Left Handrail
The handrail extension is not parallel to the floor or ground
surface.
Finding Not Parallel
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,400
$0.00
Record Number 44174
Ramp To The Clubhouse
Run 1 Left Handrail
There is not enough handrail extension beyond the top or bottom
of the rail.
Finding 5.00 inches
Code At least 12.00 inches
ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1
rovide compliant handrail extensions that are parallel to the
Dor or ground surface extending the required distance beyond
le bottom of the ramp and return smoothly to the post or wall.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,400
$0.00
Record Number 44222
Ramp To The Putting Green
Run 1
The width of the ramp is less than required.
Finding 47.50 inches
Code At least 48.00 inches
ADA 4.8.3, CA 11B-405.5
Widen the run of the ramp so that it has minimum required
width.
riority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$9,515
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 775 of 853
Record Number 44224
Ramp To The Putting Green
Run 1
The slope of the ramp is greater than the allowed slope.
Finding 8.90 percent
Code Up to 8.33 percent
ADA 4.8.2, CA 11B-405.2
odify the run of the ramp to provide the required slope and
-oss slope.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$3,600
$0.00
Record Number 44223
Ramp To The Putting Green
Run 1
The ramp run does not provide adequate edge protection to
prevent individuals from slipping off the ramp.
Finding None Found
ADA 4.8.7, CA 11B-405.9
(stall compliant edge protection on each side of the ramp run.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$470
$0.00
Record Number 44225
Ramp To The Putting Green
Run 1
There is only one handrail provided.
Finding Missing Handrail
ADA 4.8.5, CA 11B-405.8, CA 11B-505.2
Provide a compliant handrail with a compliant distance between
le handrail and the adjacent wall.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,200
$0.00
Stairs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 776 of 853
Record Number 44119
Stairs From The Golf Cart Pickup Area To The Clubhouse
Run 1
There are no handrails provided on the stairway.
Finding None Found
ADA 4.9.4, CA 11B-504.6, CA 11B-505.2
rovide compliant handrails.
riority Not Set
esolution Not Set
'regress Not Set
assignment Not Set
$1,528
$0.00
Record Number 44120
Stairs From The Golf Cart Pickup Area To The Clubhouse
Run 1
There is no detectable striping on each tread of the exterior
stairway.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
rovide compliant striping to each tread of the stairway.
riority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$944
$0.00
Record Number 44266
Stairs From The Storage To The Clubhouse
Run 1
There is no detectable striping on each tread of the exterior
stairway.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
Provide compliant striping to each tread of the stairway.
riority Not Set
esolution Not Set
'regress Not Set
_assignment Not Set
$944
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 777 of 853
Record Number 44265
Stairs From The Storage To The Clubhouse
Run 1
There are no handrails provided on the stairway.
Finding None Found
ADA 4.9.4, CA 11B-504.6, CA 11B-505.2
rovide compliant handrails.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$1,528
$0.00
Record Number 44270
Stairs To The Putting Green
Run 1
There is no detectable striping on each tread of the exterior
stairway.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
rovide compliant striping to each tread of the stairway.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$944
$0.00
Record Number 44271
Stairs To The Putting Green
Run 1 Left Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 10.50 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
Install a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
'riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 778 of 853
Record Number 44272
Stairs To The Putting Green
Run 1 Right Handrail
The top handrail extension is not the required length beyond the
top riser.
Finding 4.00 inches
Code At least 12.00 inches
ADA 4.9.4(2), CA 11B-505.10.2
(stall a compliant handrail extension to the top of the handrail
'at extends beyond the top riser and is parallel to the floor
arface of the landing.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$800
$0.00
Record Number 44287
Stairs To The Golf Cart Pickup Area
Run 1
There is no detectable striping on each tread of the exterior
stairway.
Finding None Found
ADA 4.9.5, CA 11B-504.4.1
Provide compliant striping to each tread of the stairway.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$944
$0.00
Record Number 44288
Stairs To The Golf Cart Pickup Area
Run 1 Right Handrail
There are no bottom handrail extensions provided.
Finding None Found
ADA 4.9.4(2), CA 11B-505.10.3
Install handrail extension to the bottom of the handrail that
Ktends beyond the bottom riser at least one tread depth.
tiority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$1,425
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 779 of 853
Record Number 44289
Stairs To The Golf Cart Pickup Area
Run 1 Middle Handrail
The handrail extension is not parallel with the floor surface at the
bottom landing.
Finding Not Parallel
ADA 4.9.4(2), CA 11B-505.10.3
(stall a compliant extension to the handrail.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$627
$0.00
Record Number 44290
Stairs To The Golf Cart Pickup Area
Run 1 Left Handrail
There are no bottom handrail extensions provided.
Finding None Found
ADA 4.9.4(2), CA 11B-505.10.3
Install handrail extension to the bottom of the handrail that
xtends beyond the bottom riser at least one tread depth.
'riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,425
$0.00
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44264
Womens Clubhouse Restroom
Push / Pull
The door opening force for this door is greater than allowed.
Finding 12.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
quirements.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 780 of 853
Record Number 44299
Mens Clubhouse Restroom
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44113
Open Doorway To The Golf Shop
The vertical clearance height of the open doorway is not
compliant.
Finding 78.25 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$5,600
$0.00
Record Number 44122
Golf Shop Main Entrance
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 781 of 853
Record Number 44121
Golf Shop Main Entrance
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44205
Exterior Door Near Golf Shop Check Out Counter
The height of the threshold at the sliding door is not compliant.
Finding 1.25 inches
Code Up to 0.75 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide a compliant
ireshold.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$310
$0.00
Record Number 44229
Golf Shop Office (Exterior Door)
The clear opening width of the door is less than required.
Finding 31.00 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$1,750
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 782 of 853
Record Number 44232
Golf Shop Office (Exterior Door)
Push Side
There is no level landing at this door.
Finding 2.40 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$1,500
$0.00
Record Number 44231
Golf Shop Office (Exterior Door)
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.62 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Record Number 44230
Golf Shop Office (Exterior Door)
Lever
The door opening force for this door is greater than allowed.
Finding 14.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
'riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
,25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 783 of 853
Record Number 44259
Golf Shop Office (Interior Door)
The door closing device limits the required headroom clearance.
Finding 77.87 inches
Code At least 80.00 inches
ADA 4.4.2, CA 11B-404.2.3
eplace the door closing device with a device that fits above the
Dor casing and provides a compliant clearance height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$250
$0.00
Record Number 44142
Grill Room Kitchen (East Entrance)
Push Side
There is less than the required latch side clearance on the push
side of the door.
Finding 11.50 inches
Code At least 12.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance on the push side
F the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 44141
Grill Room Kitchen (East Entrance)
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 784 of 853
Record Number 44140
Grill Room Kitchen (East Entrance)
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44152
Open Doorway From The Snack Bar To The Kitchen
The vertical clearance height of the open doorway is not
compliant.
Finding 79.25 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$5,600
$0.00
Record Number 44167
Grill Room Main Entrance
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.75 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 785 of 853
Record Number 44166
Grill Room Main Entrance
Push / Pull
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44249
Grill Room Kitchen (West Entrance)
Pull Side
There is less than the required latch side clearance on the pull side
of the door.
Finding 11.50 inches
Code At least 24.00 inches
ADA 4.13.6, CA 11B-404.2.4.1
rovide the recommended latch side clearance for the door.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,921
$0.00
Record Number 44250
Grill Room Kitchen (West Entrance)
Pull Side
There is no level landing at this door.
Finding 7.40 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 786 of 853
Record Number 44248
Grill Room Kitchen (West Entrance)
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44258
Grill Room (North Entrance)
Pull Side
There is no level landing at this door.
Finding 8.40 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 44257
Grill Room (North Entrance)
The height of the threshold at the entrance door is greater than
allowed.
Finding 0.87 inches
Code Up to 0.50 inches
ADA 4.13.8, CA 11B-404.2.5
odify or replace the threshold to provide the recommended
eight.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$436
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 787 of 853
Record Number 44256
Grill Room (North Entrance)
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44292
Open Doorway To The Snack Bar
The vertical clearance height of the open doorway is not
compliant.
Finding 78.37 inches
Code At least 80.00 inches
ADA 4.13.5
rovide a compliant open doorway at the location.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$5,600
$0.00
Record Number 44246
Womens Restroom Near Hole 14
Push Side
There is no level landing at this door.
Finding 2.70 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 788 of 853
Record Number 44245
Womens Restroom Near Hole 14
Push / Pull
The door opening force for this door is greater than allowed.
Finding 15.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44263
Mens Restroom Near Hole 14
Push Side
There is no level landing at this door.
Finding 2.80 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 44262
Mens Restroom Near Hole 14
Push / Pull
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 789 of 853
Record Number 44112
Mens Restroom Near Tee Five
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44118
Womens Restroom Near Tee Five
Push / Pull
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Counters
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44269
Golf Shop Check Out Counter
The height of the counter or desk does not comply with height
requirements.
Finding 47.87 inches
Code 28.00 - 34.00 inches
ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4
"rovide a portion of counter at the compliant height.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$3,500
$0.00
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 790 of 853
Record Number 44193
Golf Shop Managers Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 44203
Golf Shop Main Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
(stall accessible room signage.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 44298
Golf Shop Office
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 791 of 853
Record Number 44184
Room Identification Signage
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 44204
Grill Room (South Entrance)
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 44291
Grill Room Main Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
install accessible room signage.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
ATMs
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 792 of 853
Record Number 44233
Grill Room ATM
Keypad does not contain braille.
Finding See Above
Code None Found
ADA 4.34.3
TM Keypad must contain braille on it.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44137
Womens Clubhouse Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Insulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Jrasive surfaces under the lavatory.
Priority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 44138
Womens Clubhouse Restroom
Female
The gender use signage on the entrance door is not mounted at
the required height.
Finding 53.75 inches
Code 60.00 inches
CA 11B-703.7.2.6
-'ost gender use signage on the center of the door at the
quired height.
tiority Not Set
esolution Not Set
'rogress Not Set
assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 793 of 853
Record Number 44139
Womens Clubhouse Restroom
Female
The signage does not have contrasting finish from the door.
Finding See Above
CA 11B-703.7.2.6
estroom door signage should have contrasting finish.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$170
$0.00
Record Number 44201
Mens Clubhouse Restroom
The signage is not mounted at the required height.
Finding 60.50 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
3st compliant signage at the restroom.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 44199
Mens Clubhouse Restroom
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.87 inches
Code 60.00 inches
CA 11B-703.7.2.6
3st gender use signage on the center of the door at the
?quired height.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 794 of 853
Record Number 44200
Mens Clubhouse Restroom
Male
The signage does not have contrasting finish from the door.
Finding See Above
CA 11B-703.7.2.6
estroom door signage should have contrasting finish.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$170
$0.00
Record Number 44195
Mens Clubhouse Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.87 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
Dron height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,500
$0.00
Record Number 44196
Mens Clubhouse Restroom
Lavatory
The knee clearance space under the lavatory is less than the
required minimum height.
Finding 26.50 inches
Code At least 27.00 inches
CA 11B-606.2, CA 11B-306.3.1
aise or replace the lavatory to provide the minimum required
lee clearance.
riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 795 of 853
Record Number 44197
Mens Clubhouse Restroom
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 44198
Mens Clubhouse Restroom
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
)sulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 44234
Womens Clubhouse Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
Relocate the toilet so the distance from the center line of the
toilet to the nearest side wall meets the required distance.
riority Not Set
.esolution Not Set
'rogress Not Set
..ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 796 of 853
Record Number 44236
Womens Clubhouse Restroom
The toilet paper dispenser is located above the provided grab bar.
Finding Above Grab Bar
Code Relocate Dispenser
ADA 4.16.6, CA 11B-604.7
emount the dispenser below the grab bar at 19" minimum.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 44282
Mens Clubhouse Restroom
The length of the rear grab bar is less than required.
Finding 35.00 inches
Code At least 36.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2
eplace the rear grab bar with a compliant grab bar.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 44283
Mens Clubhouse Restroom
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 18.00 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 797 of 853
Record Number 44284
Mens Clubhouse Restroom
The toilet paper dispenser is located above the provided grab bar.
Finding Above Grab Bar
Code Relocate Dispenser
ADA 4.16.6, CA 11B-604.7
emount the dispenser below the grab bar at 19" minimum.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 44279
Mens Clubhouse Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44281
Mens Clubhouse Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.62 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 798 of 853
Record Number 44125
Womens Restroom Near Hole 14
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 44126
Womens Restroom Near Hole 14
Female
The signage does not have contrasting finish from the door.
Finding See Above
CA 11B-703.7.2.6
estroom door signage should have contrasting finish.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$170
$0.00
Record Number 44127
Womens Restroom Near Hole 14
Braille is not located immediately below the raised letters.
Finding None Found
ADA 4.30.4, CA 11B-703.3.2
ake sure that braille is located immediately below the raised
tters.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 799 of 853
Record Number 44124
Womens Restroom Near Hole 14
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 44133
Mens Restroom Near Hole 14
The height of the urinal rim in the restroom is not compliant.
Finding 22.25 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
Lower the urinal designated to be accessible in the restroom so
'iat the rim height is compliant.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,397
$0.00
Record Number 44134
Mens Restroom Near Hole 14
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 60.25 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 800 of 853
Record Number 44135
Mens Restroom Near Hole 14
Male
The signage does not have contrasting finish from the door.
Finding See Above
CA 11B-703.7.2.6
estroom door signage should have contrasting finish.
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
$170
$0.00
Record Number 44132
Mens Restroom Near Hole 14
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 44163
Mens Restroom Near Hole 14
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
Provide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$269
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 801 of 853
Record Number 44162
Mens Restroom Near Hole 14
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 41.75 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44160
Mens Restroom Near Hole 14
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.50 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44255
Womens Restroom Near Hole 14
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 16.00 inches
Code Up to 12.00 inches
rovide feminine products disposal at the required distance
om front of the toilet.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 802 of 853
Record Number 44254
Womens Restroom Near Hole 14
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$269
$0.00
Record Number 44252
Womens Restroom Near Hole 14
The height of the side grab bar is not at the correct height.
Finding 32.75 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 44253
Womens Restroom Near Hole 14
The grab bar on the rear wall is not at the correct height.
Finding 32.75 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 803 of 853
Record Number 44150
Mens Restroom Near Tee Five
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$269
$0.00
Record Number 44148
Mens Restroom Near Tee Five
The height of the side grab bar is not at the correct height.
Finding 34.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 44149
Mens Restroom Near Tee Five
The grab bar on the rear wall is not at the correct height.
Finding 34.50 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 804 of 853
Record Number 44146
Mens Restroom Near Tee Five
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.87 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Not Set
.esolution Not Set
'regress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44151
Mens Restroom Near Tee Five
The toilet paper dispenser is not mounted at the required height.
Finding 18.12 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Not Set
.esolution Not Set
'regress Not Set
.ssignment Not Set
$277
$0.00
Record Number 44190
Mens Restroom Near Tee Five
The height of the urinal rim in the restroom is not compliant.
Finding 22.50 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
)wer the urinal designated to be accessible in the restroom so
'at the rim height is compliant.
tiority Not Set
.esolution Not Set
'regress Not Set
.,ssignment Not Set
41,397
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 805 of 853
Record Number 44191
Mens Restroom Near Tee Five
The height of the urinal flush control in the restroom is greater
than the required maximum height.
Finding 44.12 inches
Code Up to 44.00 inches
ADA 4.18.4, CA 11B-605.4
)wer the flush control valve on the urinal to a height not
reater than the required maximum height.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$227
$0.00
Record Number 44187
Mens Restroom Near Tee Five
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.25 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,286
$0.00
Record Number 44188
Mens Restroom Near Tee Five
Lavatory
The pipes under the lavatory do not provide protection against
contact.
Finding Pipes not wrapped.
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 806 of 853
Record Number 44189
Mens Restroom Near Tee Five
Lavatory
The supply lines under the lavatory do not provide protection
against contact.
Finding Not Wrapped
ADA 4.19.4, CA 11B-606.5
Isulate or otherwise configure pipes under the lavatory to
rotect against contact. Make certain there are no sharp or
Drasive surfaces under the lavatory.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$149
$0.00
Record Number 44192
Mens Restroom Near Tee Five
Male
The signage does not have contrasting finish from the door.
Finding See Above
CA 11B-703.7.2.6
estroom door signage should have contrasting finish.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$170
$0.00
Record Number 44186
Mens Restroom Near Tee Five
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 807 of 853
Record Number 44242
Womens Restroom Near Tee Five
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 17.50 inches
Code Up to 12.00 inches
rovide feminine products disposal at the required distance
om front of the toilet.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 44241
Womens Restroom Near Tee Five
Door does not close automatically.
Finding Missing Hardware
ADA A4.17.5, CA 11B-604.8.1.2
rovide an automatic door closer, spring hinge, pull bar or
:cessible handle mounted on the inside of the compartment
Dor to the compartment designated to be accessible.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$269
$0.00
Record Number 44239
Womens Restroom Near Tee Five
The height of the side grab bar is not at the correct height.
Finding 35.00 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 808 of 853
Record Number 44240
Womens Restroom Near Tee Five
The grab bar on the rear wall is not at the correct height.
Finding 35.00 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Not Set
esolution Not Set
'regress Not Set
Assignment Not Set
$231
$0.00
Record Number 44243
Womens Restroom Near Tee Five
The toilet paper dispenser is not mounted at the required height.
Finding 18.12 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
riority Not Set
esolution Not Set
'regress Not Set
.ssignment Not Set
$277
$0.00
Record Number 44237
Womens Restroom Near Tee Five
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 18.75 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
riority Not Set
esolution Not Set
'regress Not Set
Assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 809 of 853
Record Number 44277
Womens Restroom Near Tee Five
Female
The restroom signage is not compliant.
Finding None Found
CA 11B-703.7.2.6.2
rovide compliant restroom signage.
riority Not Set
esolution Not Set
rogress Not Set
assignment Not Set
$158
$0.00
Record Number 44278
Womens Restroom Near Tee Five
Female
The signage does not have contrasting finish from the door.
Finding See Above
CA 11B-703.7.2.6
estroom door signage should have contrasting finish.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$170
$0.00
Record Number 44276
Womens Restroom Near Tee Five
Lavatory
The height of the counter surface is greater than allowed.
Finding 34.25 inches
Code Up to 34.00 inches
ADA 4.19.2, CA 11B-213, CA 11B-606.3
elocate or replace the lavatory to provide a maximum counter
arface height of no greater than recommended.
'riority Not Set
esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,286
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 810 of 853
Record Number 44275
Womens Restroom Near Tee Five
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 42.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$277
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44157
Drinking Fountain Near Hole 14
The spout outlet height is greater than required.
Finding 36.25 inches
Code Up to 36.00 inches
ADA 4.15.2, CA 11B-602.4
provide a spout outlet that does not exceed the required height.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$627
$0.00
Record Number 44158
Drinking Fountain Near Hole 14
The height of the water stream is less than required.
Finding 1.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
^,djust the flow of the water stream to a compliant height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 811 of 853
Record Number 44156
Drinking Fountain Near Hole 14
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$2,500
$0.00
Record Number 44159
Drinking Fountain Near Hole 14
The clear floor space slope is not compliant.
Finding 3.80 percent
Code Up to 2.00 percent
ADA 4.15.5, CA 11B-602.2
rovide compliant clear floor space at the drinking fountain.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,200
$0.00
Record Number 44227
Drinking Fountain At The Tee Five Restrooms
The spout outlet height is greater than required.
Finding 36.75 inches
Code Up to 36.00 inches
ADA 4.15.2, CA 11B-602.4
rovide a spout outlet that does not exceed the required height.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$627
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 812 of 853
Record Number 44228
Drinking Fountain At The Tee Five Restrooms
The height of the water stream is less than required.
Finding 1.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
djust the flow of the water stream to a compliant height.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44226
Drinking Fountain At The Tee Five Restrooms
The provided drinking fountain is not a High/Low fountain.
Finding Fountain Not Compliant
ADA 4.2.4.2, CA 11B-211.2, CA 11B-602
eplace the drinking fountain with a compliant High/Low
)untain.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$2,500
$0.00
Food Service
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44181
Outside Dinning Area
The required minimum percentage of accessible tables and seating
is not provided.
Finding None Found
Code At least 4.00 tables
ADA 4.32, ADA 7.2
modify or replace one or more of the tables in the food service
-ea to meet the required minimum accessible seating.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 813 of 853
Record Number 44267
Inside Dining Area
odify or replace one or more of the tables in the food service
-ea to meet the required minimum accessible seating.
$2,500
$0.00
The required minimum percentage of accessible tables and seating
is not provided.
Finding None Found
Code At least 2.00 tables
ADA 4.32, ADA 7.2
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44136
Womens Clubhouse Restroom
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
Tnstall visual warning devices integrated with the facility's alarm
istem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Not Set
esolution Not Set
rogress Not Set
..ssignment Not Set
$2,200
$0.00
Record Number 44194
Mens Clubhouse Restroom
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
Tnstall visual warning devices integrated with the facility's alarm
istem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Not Set
esolution Not Set
rogress Not Set
,assignment Not Set
$2,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 814 of 853
Record Number 44165
Visual Alarm
There are some visual warning devices, though visual warning
devices are not located throughout the facility.
Finding Some Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, classrooms and
eneral use rooms, accessible restrooms and other accessible
)oms.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,200
$0.00
Record Number 44180
Outside Dinning Area
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, ADA 7.2, ADA 215.2, CA 11B-215.2, CA 11B-907.5.2.3.
1
Install visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,200
$0.00
Record Number 44123
Womens Restroom Near Hole 14
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
Install visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
tiority Not Set
.esolution Not Set
'regress Not Set
,ssignment Not Set
$2,200
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 815 of 853
Record Number 44131
Mens Restroom Near Hole 14
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,200
$0.00
Record Number 44185
Mens Restroom Near Tee Five
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,200
$0.00
Record Number 44274
Womens Restroom Near Tee Five
There are no visual warning devices in this area of the facility.
Finding None Found
ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1
(stall visual warning devices integrated with the facility's alarm
/stem in all common areas such as hallways, general use
)oms, and in accessible restrooms and other accessible rooms.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,200
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 816 of 853
Record Number 44143
Snack Bar
The pipes are not wrapped for the sink.
Finding Not Wrapped
ADA 4.27, CA 11B-606.5
Isulate or Otherwise configure pipes under the sink to protect
aainst contact. Make certain there are no sharp or abrasive
arfaces under the sink.
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$149
$0.00
Record Number 44144
Snack Bar
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.25 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'regress Not Set
.ssignment Not Set
$180
$0.00
Record Number 44145
Snack Bar
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 45.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
Relocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
'regress Not Set
_assignment Not Set
$180
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 817 of 853
Record Number 44303
Employee Time Clock In Golf Shop
Time Clock - Other
The highest point of operation for the element is not compliant.
Finding 62.75 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$50
$0.00
Record Number 44286
Grill Room Kitchen First Aid Kit
First Aid Kit - Other
The highest point of operation for the element is not compliant.
Finding 65.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$50
$0.00
Record Number 44293
Water Refilling Station Near Hole 14
Water Refilling Station - Other
The clear floor space width is not compliant.
Finding 29.25 inches
Code At least 30.00 inches
ADA 4.2, CA 11B-305
Provide compliant clear floor space.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 818 of 853
Record Number 44294
rovide compliant clear floor space.
$500
$0.00
Water Refilling Station Near Hole 14
Water Refilling Station - Other
The clear floor space slope is not compliant.
Finding 4.60 percent
Code Up to 2.00 percent
ADA 4.2, CA 11B-305.2
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
Benches
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44128
Benches Near Driving Range
There are not enough accessible benches at the location with
respect to the number of benches available.
Finding None Found
Code At least 1.00 benches
ADA 5.8, ADA A4.2.6
provide compliant accessible benches at the location.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$800
$0.00
Record Number 44129
Benches Near Driving Range
The bench height is not compliant.
Finding 16.50 inches
Code 17.00 - 19.00 inches
ADA 5.8, ADA A4.2.6
Adjust the bench height to recommended value.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 819 of 853
Record Number 44130
Benches Near Driving Range
The bench is not on an accessible route.
Finding Not Accessible
ADA 5.8, ADA A4.2.6
rovide a compliant accessible route to the benches.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,840
$0.00
Fitting/Dressing Rooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44300
Golf Shop Dressing Room
There is not enough turning space to accommodate a wheelchair.
Finding 31.00 inches
Code At least 60.00 inches
ADA 4.35.2
rovide compliant turning space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,260
$0.00
Record Number 44301
Golf Shop Dressing Room
The mirror width is not compliant.
Finding 11.50 inches
Code At least 18.00 inches
ADA 4.35.5
"rovide a compliant mirror in the fitting/dressing room.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$450
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 820 of 853
Record Number 44302
Golf Shop Dressing Room
)wer the mirror so the bottom edge of the reflective surface is
D higher than recommended above the finished floor.
$277
$0.00
The bottom edge of the reflective surface of the mirror is not at
the correct height.
Finding 23.25 inches
Code Up to 20.00 inches
ADA 4.35.5
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 821 of 853
Silverrock Maintenance Building
Parking
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44311
Accessible Parking
There is no warning signage posted regarding unauthorized use of
accessible parking spaces in the parking lot.
Finding None Found
CA 11B-502.8
rovide compliant signage regarding unauthorized use of
:cessible parking spaces.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$250
$0.00
Record Number 44310
Accessible Parking
There is no device at the head of the general parking spaces to
prevent vehicles from encroaching into walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
)stall a wheel stop at the head of the general parking spaces.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$240
$0.00
Record Number 44316
Accessible Parking
Right Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 37.50 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Dace.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$220
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 822 of 853
Record Number 44312
Accessible Parking
Right Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 98.50 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Not Set
esolution Not Set
'regress Not Set
,ssignment Not Set
$350
$0.00
Record Number 44313
Accessible Parking
Right Accessible Space
The slope of the accessible parking space is not compliant.
Finding 2.50 percent
Code Up to 2.00 percent
ADA 4.6.3, CA 11B-502.4
Repave the accessible space to provide a compliant slope.
riority Not Set
esolution Not Set
'regress Not Set
Assignment Not Set
$3,800
$0.00
Record Number 44314
Accessible Parking
Right Accessible Space
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
install a wheel stop at the head of the accessible parking space.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 823 of 853
Record Number 44315
Accessible Parking
Right Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
Iternational Symbol of Accessibility.
riority Not Set
esolution Not Set
'rogress Not Set
,ssignment Not Set
$300
$0.00
Record Number 44318
Accessible Parking
Left Accessible Space
The accessible parking space does not meet the minimum
requirements for width.
Finding 107.00 inches
Code At least 108.00 inches
ADA 4.6.3, CA 11B-502
e-stripe the accessible parking space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$350
$0.00
Record Number 44319
Accessible Parking
Left Accessible Space
There is no device at the head of the accessible parking space to
prevent vehicles from encroaching into accessible aisles or
walkways.
Finding None Found
ADA 4.6.3, CA 11B-502.7.2
Install a wheel stop at the head of the accessible parking space.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 824 of 853
Record Number 44320
Accessible Parking
Left Accessible Space
There is no signage posted at the accessible parking space
showing the International Symbol of Accessibility.
Finding None Found
ADA 4.6.4, CA 11B-502.6, CA 11B-703.7.2.1
rovide compliant sigange at the accessible space.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$250
$0.00
Record Number 44317
Accessible Parking
Left Accessible Space
The accessible parking space outline is faded, damaged, missing
or otherwise not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.2
Re -stripe the existing parking space marked as accessible to
'efine the width of the space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$350
$0.00
Record Number 44321
Accessible Parking
Left Accessible Space
There is no minimum fine sign at the parking space.
CA 11B-502.6.2
rovide a minimum fine sign at the parking space below the
)ternational Symbol of Accessibility.
'riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 825 of 853
Record Number 44323
Accessible Parking
Left Accessible Space
The surface identification at the designated accessible parking
space is not compliant.
Finding 37.00 inches
Code 36.00 inches
ADA 4.6.4, CA 11B-502.6.4
rovide compliant surface identification at the accessible parking
Jace.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$220
$0.00
Record Number 44322
Accessible Parking
Left Accessible Space
ISA surface identification is faded and not viewable.
Finding Faded or Damaged
ADA 4.6.4, CA 11B-502.6.4
°epaint the ISA surface identification in the parking space.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$117
$0.00
Record Number 44324
Accessible Parking
Left Accessible Space
The access aisle at the parking space is not outlined in blue.
Finding Not Outlined in blue
CA 11B-502.3.4
''utline the access aisle in blue color.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 826 of 853
Record Number 44325
e-stripe the hatched lines in a contrasting color at a compliant
(stance on center.
$350
$0.00
Accessible Parking
Left Accessible Space
The hatched lines are striped a noncompliant distance on center.
Finding Not on 36" center
CA 11B-502.3.3
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
Curb Ramps
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44304
1st Curb Ramp From The Public Right Of Way
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
provide compliant detectable warnings to surface.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$248
$0.00
Record Number 44305
1st Curb Ramp From The Public Right Of Way
The running slope is greater than allowed.
Finding 8.70 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
^rovide a compliant curb ramp.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$1,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 827 of 853
Record Number 44306
1st Curb Ramp From The Public Right Of Way
Top Landing
The slope at the top landing is greater than allowed.
Finding 2.40 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.3
rovide a top landing that has a compliant slope and
ianeuvering space.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,260
$0.00
Record Number 44328
Right Curb Ramp From The Accessible Spaces
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
,assignment Not Set
$248
$0.00
Record Number 44346
2nd Curb Ramp From The Public Right Of Way
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
Provide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$248
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 828 of 853
Record Number 44347
2nd Curb Ramp From The Public Right Of Way
The width of the curb ramp is less than required.
Finding 47.00 inches
Code At least 48.00 inches
ADA 4.7.3, CA 11B-406.5.2
rovide a compliant curb ramp.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,300
$0.00
Record Number 44369
Left Curb Ramp From The Accessible Spaces
The curb ramp does not provide a detectable warning surface
which includes truncated domes.
ADA 4.7.7, CA 11B-406.5.12
rovide compliant detectable warnings to surface.
riority Not Set
esolution Not Set
rogress Not Set
,assignment Not Set
$248
$0.00
Record Number 44370
Left Curb Ramp From The Accessible Spaces
The running slope is greater than allowed.
Finding 8.50 percent
Code Up to 8.33 percent
ADA 4.7.2, CA 11B-406.2.2
Provide a compliant curb ramp.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,300
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 829 of 853
Record Number 44371
rovide a top landing that has a compliant slope and
ianeuvering space.
$1,260
$0.00
Left Curb Ramp From The Accessible Spaces
Top Landing
The slope at the top landing is greater than allowed.
Finding 2.60 percent
Code Up to 2.00 percent
ADA 4.3.7, CA 11B-406.5.3
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
Path of Travel
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44307
Path Of Travel From The Public Right Of Way
Exterior Walkway
There are slopes greater than allowed maximum slope on the
primary path of travel.
Finding 6.60 percent
Code Up to 5.00 percent
ADA 4.3.7, CA 11B-403.3, CA 11B-402
provide a compliant path of travel.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$3,600
$0.00
Record Number 44343
Continuing Path Of Travel From The Public Right Of Way
Path Of Travel Crosses Traffic
There are no detectable warnings where the pedestrian route
crosses vehicular traffic.
Finding None Found
ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5
rovide detectable warnings.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$190
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 830 of 853
Record Number 44344
rovide a compliant crosswalk.
$1,100
$0.00
Continuing Path Of Travel From The Public Right Of Way
Path Of Travel Crosses Traffic
The pedestrian route crosses vehicular traffic.
Finding None Found
ADA 4.29
riority Not Set
.esolution Not Set
rogress Not Set
assignment Not Set
Doors
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44335
Gate Near The Accessible Spaces
The clear opening width of the door is less than required.
Finding 25.50 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
Widen the door opening and install a door that provides at least
ie minimum clear width with the door open 90 degrees.
Priority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,750
$0.00
Record Number 44348
Main Entrance
Lever
The door opening force for this door is greater than allowed.
Finding 10.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
Adjust the closer on the door to meet the door opening force
quirements.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 831 of 853
Record Number 44361
Gate From The Public Right 0f Way
The clear opening width of the door is less than required.
Finding 25.75 inches
Code At least 32.00 inches
ADA 4.13.5, CA 11B-404.2.3
liden the door opening and install a door that provides at least
le minimum clear width with the door open 90 degrees.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,750
$0.00
Record Number 44362
Gate From The Public Right 0f Way
Push Side
There is no level landing at this door.
Finding 3.30 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
rovide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 44363
Gate From The Public Right 0f Way
Pull Side
There is no level landing at this door.
Finding 4.00 percent
Code Up to 2.00 percent
ADA 4.13.6, CA 11B-404.2.4.4
Provide a level landing.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 832 of 853
Record Number 44309
Door From The Locker Room To The Garage
Pull Side
There is not enough clear floor space provided at the pull side of
the door.
Finding 59.00 inches
Code At least 60.00 inches
ADA 4.13.6, CA 11B-404.2.4
rovide the recommended clear floor space on the pull side of
le door.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,921
$0.00
Record Number 44308
Door From The Locker Room To The Garage
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
'\djust the closer on the door to meet the door opening force
quirements.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$25
$0.00
Record Number 44331
Womens Restroom
Lever
The door opening force for this door is greater than allowed.
Finding 6.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
"djust the closer on the door to meet the door opening force
quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 833 of 853
Record Number 44355
Door From Staff Lounge To The Locker Room
Lever
The door opening force for this door is greater than allowed.
Finding 9.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44360
Mens Restroom
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$25
$0.00
Record Number 44391
Door From The Reception Area To The Break Room
Lever
The door opening force for this door is greater than allowed.
Finding 7.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
djust the closer on the door to meet the door opening force
?quirements.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$25
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 834 of 853
Record Number 44392
djust the closer on the door to meet the door opening force
?quirements.
$25
$0.00
Door From Staff Lounge To Garage
Lever
The door opening force for this door is greater than allowed.
Finding 8.00 pounds
Code Up to 5.00 pounds
CA 11B-404.2.9
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
Signage
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44330
Main Entrance
There is no room signage.
Finding None Found
ADA 4.30, CA 11B-216.2, CA 11B-216.6
Tnstall accessible room signage.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$158
$0.00
Record Number 44372
Directional Signage From Public Right Of Way
There is no directional signage.
Finding None Found
ADA 4.30, CA 11B-216.3, CA 11B-703.5
Install directional signage to each accessible element or room.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 835 of 853
Record Number 44381
Room Identification Signage
There is no compliant room identification signage provided.
Finding None Found
ADA 4.30, CA 11B-216.2
(stall compliant room identification signage.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$158
$0.00
Restrooms
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44333
Womens Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.75 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
Raise or replace the lavatory to provide the minimum required
apron height.
tiority Not Set
.esolution Not Set
'rogress Not Set
ssignment Not Set
$2,500
$0.00
Record Number 44334
Womens Restroom
The signage is not mounted at the required height.
Finding 60.12 inches on center
Code 60.00 inches on center
ADA 4.30.6, CBC 2013 11B-703.2.6
Post compliant signage at the restroom.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 836 of 853
Record Number 44332
Womens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 52.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
tiority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$277
$0.00
Record Number 44358
Mens Restroom
The height of the urinal rim in the restroom is not compliant.
Finding 17.75 inches
Code Up to 17.00 inches
ADA 4.18.2, CA 11B-605.2
Lower the urinal designated to be accessible in the restroom so
'iat the rim height is compliant.
tiority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$1,397
$0.00
Record Number 44357
Mens Restroom
Lavatory
The apron height under the lavatory is less than the required
minimum height.
Finding 28.87 inches
Code At least 29.00 inches
CA 11B-306.3.3, CA 11B-606.2
aise or replace the lavatory to provide the minimum required
Dron height.
Priority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 837 of 853
Record Number 44359
Mens Restroom
Male
The gender use signage on the entrance door is not mounted at
the required height.
Finding 59.62 inches
Code 60.00 inches
CA 11B-703.7.2.6
Dst gender use signage on the center of the door at the
?quired height.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$158
$0.00
Record Number 44356
Mens Restroom
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 53.00 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
°elocate the dispenser to the correct height.
Priority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Record Number 44379
Womens Restroom
Feminine products disposal distance from front of the toilet is not
compliant.
Finding 21.50 inches
Code Up to 12.00 inches
provide feminine products disposal at the required distance
om front of the toilet.
tiority Not Set
.esolution Not Set
'rogress Not Set
assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 838 of 853
Record Number 44377
Womens Restroom
The height of the side grab bar is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 44375
Womens Restroom
The distance between the wall and the gripping surface of the
grab bar does not meet requirements.
Finding 1.25 inches
Code At least 1.50 inches
ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3
rovide a grab bar that has a compliant gripping surface meets
I other requirements.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$250
$0.00
Record Number 44376
Womens Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.75 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 839 of 853
Record Number 44378
Womens Restroom
The grab bar on the rear wall is not at the correct height.
Finding 33.75 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Record Number 44373
Womens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
tiority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44380
Womens Restroom
The toilet paper dispenser is not mounted at the required height.
Finding 17.75 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
tiority Not Set
.esolution Not Set
'rogress Not Set
.,ssignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 840 of 853
Record Number 44388
Mens Restroom
The coat hook is not mounted at the correct height.
Finding 48.25 inches
Code 36.00 - 48.00 inches
ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3
ount the coat hook at the recommended height.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$50
$0.00
Record Number 44385
Mens Restroom
The distance from the back wall to the front of the grab bar is less
than required.
Finding 53.25 inches
Code At least 54.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609
(stall or move the grab bar to create the required distance
om the back wall to the front of the grab bar.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$267
$0.00
Record Number 44387
Mens Restroom
The grab bar on the rear wall is not at the correct height.
Finding 33.50 inches
Code 33.00 inches
ADA 4.17.6, CA 11B-609.4
emount the rear grab bar in the compartment designated to
e accessible so the height of the gripping surface is at the
)rrect height.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$231
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 841 of 853
Record Number 44386
Mens Restroom
The height of the side grab bar is not at the correct height.
Finding 33.12 inches
Code 33.00 inches
ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5
emount the grab bar so it is at the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$500
$0.00
Record Number 44389
Mens Restroom
The toilet paper dispenser is not mounted at the required height.
Finding 18.00 inches
Code At least 19.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser in the compartment to the
?quired height.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$277
$0.00
Record Number 44390
Mens Restroom
The location of the toilet paper dispenser is not within the required
distance from the front edge of the toilet seat.
Finding 17.50 inches
Code Up to 12.00 inches
ADA 4.16.6, CA 11B-604.7, CA 11B-309.4
emount the toilet paper dispenser at a compliant height and
cation.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$277
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 842 of 853
Record Number 44382
Mens Restroom
The distance from the center of the toilet to the nearest side wall
does not meet the required distance.
Finding 19.12 inches on center
Code 18.00 inches on center
ADA 4.16.2, CA 11B-604.2
elocate the toilet so the distance from the center line of the
)ilet to the nearest side wall meets the required distance.
°riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Record Number 44384
Mens Restroom
The toilet does not provide the required distance from the center
line to a fixture or wall on the wide side.
Finding 40.87 inches
Code At least 42.00 inches
ADA 4.17.3, CA 11B-604
rovide a compliant amount of clearance from the center line of
le toilet to the nearest fixture or wall on the wide side.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$2,500
$0.00
Drinking Fountains
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44326
Drinking Fountain In Maintenance
The height of the water stream is less than required.
Finding 1.00 inches
Code At least 4.00 inches
ADA 4.15.3, CA 11B-211, CA 11B-602
djust the flow of the water stream to a compliant height.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$2,500
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 843 of 853
Record Number 44327
Drinking Fountain In Maintenance
rovide the required clear floor space or reduce the depth of
le alcove.
$108
$0.00
There is not enough clear floor space for a parallel approach in an
alcove.
Finding 59.75 inches
Code At least 60.00 inches
ADA 4.2.4.2, CA 11B-602.2, CA 11B-305.7.2
°riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
Emergency Warning Systems
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44329
Visual Alarm
There are no visual warning devices at the facility.
Finding None Found
ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702
Tnstall visual warning devices integrated with the facility's alarm
istem in all common areas.
Priority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$2,200
$0.00
Break/Conference Room
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44365
Employee Break Room
Sink counter height does not meet the standards.
Finding 35.37 inches
Code Up to 34.00 inches
CA 11B-606.3
rovide compliant sink.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 844 of 853
Record Number 44366
Employee Break Room
Sink knee clearance does not meet the standards.
Finding 26.25 inches
Code At least 27.00 inches
ADA 4.27
rovide compliant sink.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,800
$0.00
Record Number 44367
Employee Break Room
The toe kick for the sink in break/conference room is not removed.
Finding Not Removed
CA 11B-606.2, CA 11B-305, CA 11B-306
emove the toe kick for the sink.
riority Not Set
esolution Not Set
'rogress Not Set
Assignment Not Set
$612
$0.00
Record Number 44368
Employee Break Room
The pipes are not wrapped for the sink.
Finding Not Wrapped
CA 11B-606.5
Isulate or otherwise configure the water supply and drain
Ipes under the sink to protect against contact. Make certain
sere are no sharp or abrasive surfaces under the sink.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$149
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 845 of 853
Record Number 44364
Employee Break Room
There is no International Symbol of Accessibility designating this
table as accessible
Finding None Found
ADA 4.27
(stall an International Symbol of Accessibility at the table.
riority Not Set
.esolution Not Set
rogress Not Set
_,ssignment Not Set
$158
$0.00
Sinks
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44393
Maintenance Bay
Sink counter height is not compliant.
Finding 35.37 inches
Code Up to 34.00 inches
ADA 4.27, CA 11B-606.3
provide compliant sink.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$1,800
$0.00
Record Number 44394
Maintenance Bay
Soap
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 49.50 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
"elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$180
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 846 of 853
Record Number 44395
Maintenance Bay
Paper Towel
The height of the controls and operating mechanisms for the
dispenser is not at the correct height.
Finding 55.75 inches
Code Up to 40.00 inches
ADA 4.23.7, ADA 4.22.7, CA 11B-603.5
elocate the dispenser to the correct height.
riority Not Set
.esolution Not Set
rogress Not Set
,ssignment Not Set
$180
$0.00
Picnic Areas
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44342
Picnic Tables
The required percentage of picnic tables provided are not
accessible.
Finding None Found
Code At least 1.00 tables
ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6
provide a sufficient number of compliant picnic tables.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$500
$0.00
Lockers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44345
Employee Lockers
No accessible lockers were found.
Finding Not Available
CA 11B-225.2.1, CA 11B-811
rovide a compliant amount of accessible lockers.
riority Not Set
.esolution Not Set
rogress Not Set
Assignment Not Set
$1,840
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 847 of 853
Accessible Showers
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Record Number 44337
Accessible Shower In The Womens Restroom
The grab bars in the accessible shower are not mounted at a
compliant height.
Finding 38.00 inches
Code 33.00 - 36.00 inches
ADA 4.21.4, CA 11B-609.4, CA 11B-608.3
Remount the grab bars in the accessible shower to a compliant
sight and location.
riority Not Set
esolution Not Set
rogress Not Set
.ssignment Not Set
$78
$0.00
Record Number 44338
Accessible Shower In The Womens Restroom
The grab bar is mounted on walls over the seat.
Finding Over Seat
ADA 4.21.4, CA 11B-609, CA 11B-608.3
Move the grab bar so that it is mounted on walls opposite and
ijacent to the front edge of the seat, but not extended to
Iclude that portion of wall over the seat.
riority Not Set
esolution Not Set
rogress Not Set
..ssignment Not Set
$1,840
$0.00
Record Number 44339
Accessible Shower In The Womens Restroom
Shower seat length is not compliant.
Finding Not Accessible
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
"rovide a compliant seat that extends the full length of the
lower.
Priority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,068
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 848 of 853
Record Number 44340
Accessible Shower In The Womens Restroom
The folding seat in the accessible shower is not mounted at a
compliant height above the finished floor.
Finding 18.75 inches
Code 18.00 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
emount the folding seat to a compliant height above the
nished floor.
°riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 44336
Accessible Shower In The Womens Restroom
The center line of the hand-held sprayer unit is not a compliant
distance from the rear of the seat edge.
Finding 37.50 inches
Code Up to 27.00 inches
ADA 4.21, ADA 4.21.6, CA 11B-608.5
rovide a compliant hand-held sprayer unit with a hose.
riority Not Set
.esolution Not Set
rogress Not Set
,assignment Not Set
$385
$0.00
Record Number 44341
Accessible Shower In The Womens Restroom
The water control valve is not mounted at a compliant height.
Finding 43.00 inches
Code Up to 40.00 inches
ADA 4.21.5, CA 11B-608.5
Remount the water control valve.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$554
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 849 of 853
Record Number 44351
Accessible Shower In The Mens Restroom
Shower seat length is not compliant.
Finding Not Accessible
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
rovide a compliant seat that extends the full length of the
lower.
riority Not Set
.esolution Not Set
rogress Not Set
.ssignment Not Set
$1,068
$0.00
Record Number 44352
Accessible Shower In The Mens Restroom
The folding seat in the accessible shower is not mounted at a
compliant height above the finished floor.
Finding 18.37 inches
Code 18.00 inches
ADA 4.21.3, CA 11B-608.4, CA 11B-610.3
emount the folding seat to a compliant height above the
nished floor.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 44349
Accessible Shower In The Mens Restroom
The grab bars in the accessible shower are not mounted at a
compliant height.
Finding 37.50 inches
Code 33.00 - 36.00 inches
ADA 4.21.4, CA 11B-609.4, CA 11B-608.3
emount the grab bars in the accessible shower to a compliant
eight and location.
riority Not Set
.esolution Not Set
'rogress Not Set
Assignment Not Set
$78
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 850 of 853
Record Number 44350
Accessible Shower In The Mens Restroom
The grab bar is mounted on walls over the seat.
Finding Over Seat
ADA 4.21.4, CA 11B-609, CA 11B-608.3
ove the grab bar so that it is mounted on walls opposite and
ijacent to the front edge of the seat, but not extended to
'elude that portion of wall over the seat.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,840
$0.00
Record Number 44353
Accessible Shower In The Mens Restroom
The water valve distance from seat wall is not compliant.
Finding 39.00 inches
Code 18.00 - 24.00 inches
ADA 4.21.5, CA 11B-608.5
rovide a compliant water valve.
riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$1,500
$0.00
Record Number 44354
Accessible Shower In The Mens Restroom
The water control valve is not mounted at a compliant height.
Finding 44.25 inches
Code Up to 40.00 inches
ADA 4.21.5, CA 11B-608.5
emount the water control valve.
°riority Not Set
esolution Not Set
rogress Not Set
Assignment Not Set
$554
$0.00
Reach Ranges
Finding
Recommendation
Projected Date
Actual Date
Est. Cost
Act. Cost
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 851 of 853
Record Number 44396
Employee Time Clock In Maintenance Bay
Employee Time Clock - Other
The highest point of operation for the element is not compliant.
Finding 61.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$50
$0.00
Record Number 44397
First Aid Kits In Maintenance Bay
First Aid Kits - Other
The highest point of operation for the element is not compliant.
Finding 65.50 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Not Set
.esolution Not Set
'rogress Not Set
,ssignment Not Set
$50
$0.00
Record Number 44398
Emergency Eye Wash Station In The Maintenance Bay
Emergency Eye Wash Station - Eye Washing Station
The highest point of operation for the element is not compliant.
Finding 58.00 inches
Code 15.00 - 48.00 inches
ADA 4.2, CA 11B-308, CA 11B-309
ake sure that the highest point of operation is within the
?commended value.
riority Not Set
.esolution Not Set
'rogress Not Set
.ssignment Not Set
$50
$0.00
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 852 of 853
Disability Access Consultants, LLC (DAC) 1-800-743-7067
Page 853 of 853