Loading...
HomeMy WebLinkAboutRFP ADA Accessibility Consulting Services - Addendum 2ADDENDUM NO. 2 TO REQUEST FOR PROPOSALS Date: June 4, 2026 To: All prospective proposers RFP: AMERICANS WITH DISABILITIES ACT ACCESSIBILITY COMPLIANCE ASSESSMENT AND TRANSITION PLAN CONSULTING SERVICES The following shall be considered as incorporated into the Request for Proposals for the above referenced consulting services, published on May 18, 2026. The following are the City's responses to all questions received as part of this RFP process: Proposals — Consideration, Subcontracting, Timeline, Budget, ADA Coordinator, CASP Certification Question No. 1: Will the City consider proposals scoped only to the web and digital accessibility components (Task 4, and the digital portions of Tasks 6, 7, and 8), or must proposers respond to the full scope? Question No. 2: Is the City seeking a single vendor with demonstrated capabilities across both physical and IT accessibility domains? Question No. 3: If separate areas of expertise are acceptable, would a proposal limited in scope to IT / digital accessibility solutions be considered compliant and evaluated accordingly? Answer: The City will consider limited scope proposals to only one or only a few of the requested services from qualified firms. Question No. 4: Section 111.6 indicates that subcontracting is not preferable but may be considered when in the City's best interest. Given the multidisciplinary nature of this scope (physical facilities, public right-of-way, programmatic, and digital accessibility), will proposals that team a prime with specialist subcontractors be evaluated on equal footing with single -firm proposals, provided the subcontracting structure is fully disclosed and justified? Answer: Yes. When fully disclosed and properly justified, proposals that include subcontractors will be evaluated on an equal basis with all other proposals. Question No. 5: Is there a completion timeframe and budget in mind? Question No. 6: Is there an estimated project budget or not -to -exceed amount? Question No. 7: Is there an established budget or not -to -exceed amount for this project that consultants should be aware of when developing their proposals? Page 1 of 7 hiadiftei Question No. 8: Project Budget and Implementation Planning Expectations — please clarify whether the City has an anticipated project budget range, target implementation phases, preferred prioritization methodology, or expectations regarding the level of detail required for cost estimating and capital improvement planning within the ADA Transition Plan. Question No. 9: Is there a target completion date or desired timeframe for delivery of the final Transition Plan? Answer: At this time, the City does not have a specific completion timeline or budget. These will be established based on the compliance items identified in the City's self -assessment, which will be conducted by the firm selected under this RFP, to bring the City into compliance with current ADA regulations. The City's intent is for the selected firm to address as many items as is feasible in the Transition Plan(s) before the April 26, 2028, compliance deadline. Question No. 10: Does the City anticipate a lump sum or time -and -materials contract structure for this engagement? Answer: All proposals received will be considered. The manner in which a proposal is submitted is at the discretion of each firm. Question No. 11: Does the City currently have a designated ADA Coordinator? If so, will that individual serve as the primary point of contact throughout the project? Answer: Yes, the City has a designated ADA Coordinator. Several City staff members from departments citywide will be primary points of contact throughout the project. Question No. 12: Is CASP certification (Certified Access Specialist) required for this RFP? Answer: GASP certification is not required for this RFP, as the federal ADA focuses on compliance with ADA standards, and does not specify any particular credentials for someone to perform accessibility evaluations; however, it is recommended. Digital Accessibility Question No. 13: Is the vendor expected to perform hands-on remediation of any web pages, documents (PDFs, Word), or multimedia, or only to identify accessibility issues and provide remediation recommendations and a roadmap as part of the Transition Plan? Answer: The firm selected under this RFP is expected to identify accessibility barriers, recommend appropriate remediation measures, prepare a digital accessibility Transition Plan, and collaborate with City staff to develop a roadmap for achieving compliance. Question No. 14: If remediation of assets is expected, can the City please specify which types and approximate volumes? Answer: The firm selected under this RFP is expected to identify this information as part of the scope of work. Page 2 of 7 athita �,iI,ORNIA Question No. 15: How many public -facing documents (PDFs, Word, etc.) are in scope, and what is the approximate total page volume? Answer: The firm selected under this RFP is expected to identify this information as part of the scope of work. Question No. 16: How many public -facing websites, subsites, web applications, portals, and online forms/payment systems are in scope? Can the City provide the URLs or an inventory? Question No. 17: Please identify the City's digital assets to be assessed, including the number of websites/subsites, web applications, portals, online forms, payment systems, mobile apps, PDFs/documents, and multimedia files. Answer: ➢ Digital assets — The firm selected under this RFP is expected to identify this information as part of the scope of work. ➢ Websites / subsites — City website (https://www.laquintaca.gov); City tourism website (https://www.playinlaquinta.com) ➢ Web applications, portals, payment systems, mobile apps — Enclosed as Attachment 1 to this Addendum No. 2 is the City's Enterprise Systems Catalog for a list of public - facing software and hosted services used by City departments that collect, store, exchange, or analyze information about the public or City operations. ➢ Online form, PDFs / documents, and multimedia files — unknown; the firm selected under this RFP is expected to identify this information as part of the scope of work. Question No. 18: For the digital accessibility assessment, does the City anticipate: a comprehensive review of all digital content and documents, statistically valid sampling, department -based sampling, or prioritized/high-use content review? Answer: The firm selected under this RFP is expected to conduct a comprehensive review of all digital content and identify accessibility barriers, recommend appropriate remediation measures, prepare a digital accessibility Transition Plan, and collaborate with City staff to develop a roadmap for achieving compliance. ADA Transition Plan Question No. 19: Does the City have an existing ADA Transition Plan? Would this process be an update to an existing assessment(s)? Question No. 20: Is this the City's first time completing a self -evaluation and ADA Transition Plan, or is this an update to an existing plan? If an existing plan is in place, will it be made available to the selected consultant? Page 3 of 7 Question No. 21: Beyond the written Transition Plan document, does the City anticipate needing a platform or database solution to track identified deficiencies, prioritize corrective actions, and monitor progress toward compliance over time? Question No. 22: Is there a target completion date or desired timeframe for delivery of the final Transition Plan? Question No. 23: Please identify any existing ADA transition plans, self -evaluations, facility inventories, GIS databases, curb ramp inventories, digital accessibility audits, remediation reports, or related accessibility documentation that will be made available to the selected consultant. Answer: The City has completed a self -evaluation and ADA Transition Plan previously and is seeking to update the existing plan, which will be made available to the firm selected under this RFP. Enclosed as Attachment 4 to this Addendum No. 2 is an ADA Transition Plan Report as of April 1, 2026. At this time, the City does not have a specific completion timeline; it will be established based on the compliance items identified in the City's self -assessment, which will be conducted by the firm selected under this RFP to bring the City into compliance with current ADA regulations. The City's intent is for the selected firm to address as many items as is feasible in the Transition Plan(s) before the April 26, 2028, compliance deadline. Facilities Accessibility Question No. 24: Does the City know how many sidewalks, curb ramps and intersections it operates? Question No. 25: Please provide a count and listing (or map) of city -owned properties/facilities included as part of the compliance evaluation. Question No. 26: May we have the following information for the sites included in the assessment: Facilities — square footage; Parks — amenities, acreage, trail information. Question No. 27: May we have a list of facilities that are in scope including details of their use? Question No. 28: Please provide a complete inventory of City facilities, parks, parking lots, and other sites to be assessed, including names, addresses, approximate square footage, and site types. Question No. 29: How many facilities are anticipated to be included in the self -evaluation? If available, could you provide the approximate square footage and location of each facility? Question No. 30: Please provide a list of facilities that will need to be surveyed. Question No. 31: Please provide a list of any parks that will need to be surveyed. Page 4 of 7 Question No. 32: The RFP does not contain a list of leased and owned facilities. Can the City provide a list of facilities, parks, parking lots, etc. to be included in the project to develop the fee proposal? Answer: Enclosed as Attachment 2 to this Addendum is a list of City facilities incorporated into the scope of work under this RFP. Answer: Enclosed as Attachment 3 to this Addendum is a list of City parks and recreation facilities incorporated into the scope of work under this RFP. Question No. 33: Please provide available public right-of-way inventory quantities, including sidewalk miles, curb ramps, intersections, signalized crossings, pedestrian push buttons. Question No. 34: Can the City provide an estimate of the total sidewalk miles and number of curb ramps within its boundaries? Question No. 35: Does the City know how many sidewalks, curb ramps and intersections it operates? Question No. 36: May we have the following information for the sites included in the assessment: PROW — Number of signalized intersections / stop lights. Question No. 37: Please provide quantities for the following: a) A count and listing (or map) of the City -owned properties / facilities included as part of the compliance evaluation b) Miels of Sidewalk c) A count of Crosswalks d) Estimated number of curb ramps e) Estimated count of signals / signalized intersections included in the project f) Number of policies to be evaluated Question No. 38: Can the City provide an estimate of the total sidewalk miles and number of curb ramps within its boundaries? Question No. 39: The RFP requests that the consultant assess the Public Rights -of -Way. In order to ensure all bidders utilize the same metrics within the PROW for the fee proposal, can the City provide the mileage of sidewalk, number of curb ramps, number of signalized intersections and pedestrian push buttons, number of on -street accessible parking stalls, and the number of transit stops required to be assessed as part of the assessment process? Question No. 40: Please share how many miles of sidewalks will need to be surveyed. Question No. 41: Please share how many intersections will need to be surveyed, including curb ramps, pedestrian crossings, and pedestrian signals. Question No. 42: Provide an estimate of how many on -street parking / parking lots will need to be surveyed. Page 5 of 7 Question No. 43: Please indicate whether transit stops and shelters will be a part of the PRoW evaluation and, if so, how many. Answer: The City owns and operates 121 miles of sidewalk. Answer: The City owns and operates approximately 500 crosswalks, and 20 painted crosswalks. Answer: The City owns and operates approximately 400 to 415 pedestrian push buttons. Answer: The City owns and operates 56 signalized intersections; the number of non -signaled intersections are unknown Answer: The current number of curb ramps is unknown; the firm selected under this RFP is expected to identify this information as part of the scope of work. Answer: Approximately 40-50 administrative policies citywide will need to be evaluated as part of the scope of work under this RFP. Answer: The City does not own or operates on -street accessing parking stalls. Answer: The City does not own or operate any transit stops as they are owned and operated by Sunline Transit Agency. Answer: The City owns, operates, and will need to have assessed off-street accessible parking stalls at the following locations: ✓ Cove Trailhead West ✓ Fire Station - Desert Club and 52 ✓ Cove Trailhead East V Maintenance and Operations Yard ✓ Fire Station - Madison and Ave 54 ✓ La Quinta Library ✓ Bear Creek Trail - Eisenhower and ✓ Wellness Center Tampico V Civic Center North Lot ✓ La Quinta Museum ✓ Civic Center South Lot ✓ La Quinta Community Park ✓ Point Happy Park ✓ Navarro Plaza V X-Park ✓ Montezuma Parking Lot V La Quinta Park ✓ Avenida La Fonda Parking ✓ Pioneer Park ✓ Calle Estado Parking V Sports Complex ✓ Fritz Burns Park ✓ YMCA - Moon River Question No. 44: Does the City have any restrictions on use of small mobile inspection platforms/motorized carts that can be driven on public sidewalks? Answer: The City has no restrictions on the use of small mobile inspection platforms or motorized carts for public sidewalks. Page 6 of 7 hiadiftei 11 I I n I< N I A - Question No. 45: Does the City currently utilize a GIS platform? If so, would geospatial data such as facility locations, parcel boundaries, or existing infrastructure layers be available to the consultant? Question No. 46: Does the City require GIS deliverables? If yes, please identify the required platform, file format, schema, coordinate system, and whether the City will provide existing GIS layers. Answer: Yes, the City does utilize a GIS platform. Yes, the City's GIS mapping and special data management, and the files would be made available to the firm selected under this RFP. The City's GIS requirements are as follows: File Format: • File Geodatabase (.gdb) — preferred as the primary deliverable format • Shapefiles (.shp) are acceptable as a secondary/backup format but not preferred (field length limits, no domain support, etc.) Coordinate system is NAD 1983 StatePlane California Zone 6 (FIPS 0406), WKID 2230 • Feature types broken out logically (sidewalks, curb ramps, barriers, accessible parking, etc.) as separate feature classes or at minimum a feature type attribute • Condition/compliance fields with domain -coded values (not free text) • A unique identifier field (AssetlD, etc) • Photo attachment capability if necessary (photo IDs, etc) Question No. 47: Please clarify whether the consultant's responsibilities are limited to assessment, planning, and recommendations, or whether the City expects hands-on remediation support for physical barrier corrections during the contract term. Answer: The City does not expect hands-on remediation support for physical barrier corrections. In all other respects the original RFP shall remain in effect. ******************************************************* Published June 4, 2026 ( Monika Radeva, City Clerk City of La Quinta End of Addendum No. 2 Page 7 of 7 City of La Quinta Enterprise Systems Catalog Pursuant to Senate Bill 272 (Gov. Code § 7922.700; Formerly Gov. Code § 6270.5) ATTACHMENT 1 City of La Quinta Catalog Last Updated: January 26, 2026 In accordance with California Senate Bill 272 (2015), the City of La Quinta publishes this catalog of enterprise information systems. This catalog lists software and hosted services used by City departments that collect, store, exchange, or analyze information about the public or City operations. Free or publicly available utilities (such as Microsoft Edge or Adobe Reader) are excluded. Requirement/Aspect Former Location (Pre-2023) Current Location (Post -AB 473) Enterprise Systems Catalog Section 6270.5 Sections 7922.700-7922.725 Disclosure Rules Section 6270.5 7922.710, 7922.715, 7922.720 Definitions & Exclusions Section 6270.5 7922.700 Legal Reference Section 6270.5 7922.700-7922.725 Effective Date 2016 (SB 272) Jan 1, 2023 (AB 473) IA IT Creative Cloud PDF editing and design software for City staff mi1Documents Daily Applied Geodetics, Inc. IT GIS Consulting Services Maintains LQGIS database and TRAKit integration Spatial / Infrastructure Data Monthly Monthly AutoDesk MN" BlueBeam Inc. Design & Development Public Works / Building AutoCAD / Civil 3D Studio Prime Architectural design and plan review Electronic plan review and markup integrated with Tyler Documents As Needed Daily As Needed Daily ICablecast (Triton Technologies) City Clerk Carahsoft Technology Corp IT .iteflect Server + Zoom Phone Services Broadcast and Record public meetings for public access (Video Recordings / Access Logs Citywide telecommunications and conferencing platform User Accounts, Call Metadata, Recordings ■I Per Meeting Continuous Continuous As Needed DataTicket Public Safety/Code Compliance Citation Processing Track and manage parking and administrative citations Citation information, case data, including violation through enforcement, adjudication, and collection details, vehicle and respondent information, hearing processes. outcomes, payments, and collection activity. IF' Continuous Continuous Deckard Technologies, Inc. City Clerk RentalScape Short -Term Vacation Rental Program Compliance Monitoring Residential business rental activities Continuous Continuous DocuSign eSignature Platform Digital signing of City forms and contracts 1 Documents / Signatures As Needed ESRI IT / Design & Development ArcGIS Online / ArcGIS Pro GIS mapping and spatial data management Geographic / Spatial Data Weekly / Continuous Monthly GoGov IIMIM Code Compliance & GoEnForce Facilities GoRequest Code Enforcement Case Management & Citizen Requests Electronic code actions tracking Daily Daily Governmentiobs.com, Inc. DBA NEOGOV Human Resources NeoGov Online Application System Recruitment System / Job Applications As Needed As Needed Govinvest, Inc. r Finance •IGiovinvest Pension & Health Benefits Management & Actuarial Reporting 'Pension & other post -employment benefits (OPEB) I Annually Annually GovOS City Clerk MUNIRevs LodgingRevs Short -Term Vacation Rental Program Management, TOT Collection, Compliance Monitoring Electronic permit applications management & tracking; online payments; compliance monitoring Continuous Continuous Granicus IT Vision City Website Content Management City website public information & documents Daily Daily JCG Technologies, Inc City Clerk Liberty Meeting Recorder & Player Audio recordings of public meetings Audio Recordings As Needed As Needed LaserFiche J City Clerk Digital Archive Repository — On Prem Electronic document management system 1 Documents / Records Continuous Continuous Microsoft (via Riverside County) IT Microsoft 365 (Visual Edge IT administered) Citywide email, file sharing, and collaboration Email & Documents Continuous Daily PastPerfect Museum Past Perfect 5.0 Collection Management Museum / Local history archives MIMI Daily Dai Ring (Amazon Services) IT Ring Protect / Ring for Business Server room video monitoring for security and access control Video Recordings / Access Logs Continuous Continuous Tyler Technologies Design & Development Permitting & Licensing Management Electronic project & permit applications management & tracking; online applications & payments Continuous Continuous Tyler Technologies Finance Incode / Munis ERP Financial and HR Management system Finance, Accounting, Personnel Management Continuous Continuous Vermont Systems, Inc. Community Services RecTrak Recreation Class & Membership Management Registration for classes, programs, events & rentals ATTACHMENT 2 City of La Quinta Facilities Facility Name Location Sq. Ft. 1 Boys & Girls Club 49995 Park Avenue 12,000 2 City Hall/Civic Center 78495 Calle Tampico 54,553 3 Colonel Mitchell Paige Restroom Building 43495 Palm Royale Dr. 125 4 Cove Restroom (Cove to Lake trailhead) Avenida Bermudas & CalleTecate 50 5 Fire Station 32 78111 Avenue 52 7,500 6 Fire Station 32 (OLD) 78-136 Francis Hack Lane 5,000 7 Fire Station 70 54001 Madison Street 5,700 8 Fire Station 93 44555 Adams Street 7,700 9 Fritz Burns Pool 51885 Avenida Bermudas 1,900 10 La Quinta Library 78275 Calle Tampico 20,500 11 La Quinta Museum 77885 Avenida Montezuma 7,700 12 La Quinta Park (Restroom/Snack) 79120 Westward Ho 2,600 13 La Quinta Realty Building 51001 Eisenhower 1,000 14 La Quinta YMCA 49955 Moon River Drive 10,000 15 Old Lumber Yard 77895 Avenida Montezuma 2,570 16 Public Works Building 78106 Frances Hack Lane 2,200 17 Silver Rock Event Building 51900 Silver Rock Way 4,300 18 Silver Rock Event Restrooms Building 51900 Silver Rock Way 500 19 SilverRock Clubhouse 79179 Ahmanson Lane 4,800 20 SilverRock Maintenance Yard 79600 Avenue 54 10,000 21 Sports Complex 78900 Avenue 50 880 22 Wellness/Senior Center 78450 Avenida La Fonda 22,000 23 X-Park Building 46170 Dune Palms Road 1,500 ATTACHMENT 3 Park Address Acreage Amenities 1 Adams Park 3.5 1994 2 Bear Creek Trail 2.6 miles 1991 3 Civic Center Campus 17.5 2002 *4 Colonel Mitchell Page 43495 Palm Royale Drive Restr000ms 5 Cove Oasis Trailhead 12 2001 6 Desert Pride Park 1 2000 7 Eisenhower park 0.5 2002 *8 Fritz Burns Park 12 1994 Pool - Restrooms - Snack Bar Fred Wolff Bear Creek 9 Nature Preserve 28 2006 * 10 La Quinta Park 18 2002 Restr000ms - Snack bar 11 Monticello Park 4 2003 12 Pioneer Park (inc.Well Site) 3.2 2008 13 Saguaro Park 0.75 2002 14 Seasons Park 5 2000 15 Velasco Park 0.25 2002 16 Sports Complex 17 SRR Event Park 18 X-Park LQ Middle School 51930 SilverRock Way Black Hawk Way/Dune Palms 17 11.5 3.5 2021 Restrooms/Alongi Bldg/stage CLQ Facilities Address Acreage Age Phone # *1 LQ Library 78275 Calle Tampico 20,000 sf 2005 (760)564-4767 *2 LQ Historical Museum 77885 Avenida Montezuma 924sf(8,000addition) 2008 (760)777-7170 *3 Wellness Center 78450 Avenida La Fonda 10,000 sf 1994 *4 Silverrock Resort 79179 Ahmanson Ln 525 2005 (760)777-8884 5 Old LumberYard Montezuma 1 Other Facilities Address Acreage Phone # 1 Boys & Girls Club 49995 Park Ave 12,000 sf 2 LQ Community Park Blackhawk Way 6.5 5 YMCA 49955 Moon River 10,000 sf (760)771-1811 i A School Facilities 6 Address Acreage s Phone # 6 Sports Complex 78900 Avenue 50 16.75 (760)564-2268 Boys & Girls Club Parking ATTACHMENT 4 Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30595 Parking Off Of Park Avenue There is no device at the head of the general parking spaces to prevent vehicles from encroaching into walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 )stall a wheel stop at the head of the general parking spaces. tiority Three esolution Not Set 'rogress Not_Started .ssignment Not Set $240 $0.00 Record Number 30608 Parking Off Of Park Avenue Parking Lot Warning Sign The point of contact and telephone number for reclaiming towed vehicles have been left blank. Finding Sign not Filled CA 11B-502.8.2 II in the blank spaces with the point of contact and telephone umber for reclaiming towed vehicles. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 30596 Parking Off Of Park Avenue Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 98.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 Re -stripe the accessible parking space. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 1 of 853 Record Number 30597 Parking Off Of Park Avenue Left Accessible Space The slope of the accessible parking space is not compliant. Finding 9.10 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. riority Five .esolution Not Set 'rogress Not_Started assignment Not Set $3,800 $0.00 Record Number 30598 Parking Off Of Park Avenue Left Accessible Space There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 istall a wheel stop at the head of the accessible parking space. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 30599 Parking Off Of Park Avenue Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 2 of 853 Record Number 30601 Parking Off Of Park Avenue Left Accessible Space There is no additional signage marked "van accessible" at the van accessible parking space. Finding None Found ADA 4.6.4 an accessible parking spaces shall provide additional signage 'at states "van accessible" . riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 30602 Parking Off Of Park Avenue Left Accessible Space The slope of the access aisle is not compliant. Finding 5.20 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 °epave the access aisle to provide a compliant surface slope. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $3,800 $0.00 Record Number 30600 Parking Off Of Park Avenue Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 37.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 provide compliant surface identification at the accessible parking Dace. riority Five esolution Not Set 'rogress Not_Started _.ssignment Not Set $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 3 of 853 Record Number 30603 Parking Off Of Park Avenue Right Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 104.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Five esolution Not Set 'regress Not_Started ,ssignment Not Set $350 $0.00 Record Number 30604 Parking Off Of Park Avenue Right Accessible Space The slope of the accessible parking space is not compliant. Finding 7.20 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 Repave the accessible space to provide a compliant slope. riority Five esolution Not Set 'regress Not_Started Assignment Not Set $3,800 $0.00 Record Number 30605 Parking Off Of Park Avenue Right Accessible Space There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 install a wheel stop at the head of the accessible parking space. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 4 of 853 Record Number 30606 Parking Off Of Park Avenue Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set $300 $0.00 Record Number 30607 Parking Off Of Park Avenue Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 37.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $220 $0.00 Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30631 Curb Ramp From The Parking Lot North East Of The Main Entrance The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Five esolution Not Set rogress Not_Started Assignment Not Set $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 5 of 853 Record Number 30632 Curb Ramp From The Parking Lot North East Of The Main Entrance The running slope is greater than allowed. Finding 8.80 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 rovide a compliant curb ramp. riority Five .esolution Not Set rogress Not_Started _,ssignment Not Set $1,300 $0.00 Record Number 30633 Curb Ramp From The Parking Lot North East Of The Main Entrance The slope of the curb ramp left side flare is greater than allowed. Finding 15.20 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 rovide curb ramp side flares with a compliant slope. riority Five .esolution Not Set rogress Not_Started ,assignment Not Set $1,300 $0.00 Record Number 30634 Curb Ramp From The Parking Lot North East Of The Main Entrance Bottom Landing The slope at the bottom landing is greater than allowed. Finding 6.20 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.3.2 rovide a compliant bottom landing that does not exceed the iaximum slope requirements. Priority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set $240 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 6 of 853 Record Number 30719 Curb Ramp At The Head Of The Access Aisle The curb ramp projects into vehicular traffic lanes, parking spaces, or parking access aisles. Finding Projects ADA 4.7.6, CA 11B-406.5 rovide a compliant curb ramp. riority Five .esolution Not Set rogress Not_Started _,ssignment Not Set $1,400 $0.00 Record Number 30720 Curb Ramp At The Head Of The Access Aisle The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Five esolution Not Set rogress Not_Started ,assignment Not Set $248 $0.00 Record Number 30721 Curb Ramp At The Head Of The Access Aisle Top Landing The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. Finding None Found CA 11B-406.5.11 rovide a compliant grooved border along the top and sides of le curb ramp at the level surface of the sidewalk. Priority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 7 of 853 Record Number 30783 Curb Ramp From Crosswalk Next To YMCA Facility The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Five esolution Not Set rogress Not_Started _,ssignment Not Set $248 $0.00 Record Number 30784 Curb Ramp From Crosswalk Next To YMCA Facility The slope of the curb ramp left side flare is greater than allowed. Finding 26.30 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 rovide curb ramp side flares with a compliant slope. riority Five esolution Not Set rogress Not_Started Assignment Not Set $1,300 $0.00 Record Number 30785 Curb Ramp From Crosswalk Next To YMCA Facility Bottom Landing The slope at the bottom landing is greater than allowed. Finding 7.90 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.3.2 rovide a compliant bottom landing that does not exceed the iaximum slope requirements. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set $240 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 8 of 853 Record Number 30786 atch the transition area at the bottom of the curb ramp so that le transition is flush and free of abrupt changes. $255 $0.00 Curb Ramp From Crosswalk Next To YMCA Facility Bottom Landing The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. Finding 1.00 inches Code Up to 0.50 inches ADA 4.5.2, ADA 406.5.8 riority Five .esolution Not Set rogress Not_Started Assignment Not Set Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30775 Ramp To City Owned Room West Entrance Run 1 Bottom Landing The length of the bottom landing does not meet the required minimum length. Finding 55.50 inches Code At least 72.00 inches ADA 4.8.4, CA 11B-405.7.3.1 odify or replace the bottom landing to provide the required iinimum length and width. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $2,87, $0.00 Record Number 30778 Ramp To City Owned Room West Entrance Run 1 Intermediate Landing The ramp changes direction. The length of landing is less than the required minimum length. Finding 55.00 inches Code At least 72.00 inches ADA 4.8.4, CA 11B-405.7.4 Modify or replace landing to provide the required minimum length and width. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set $2,872 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 9 of 853 Record Number 30776 Ramp To City Owned Room West Entrance Run 1 Intermediate Landing The ramp changes direction. The width of the landing does not meet the minimum required width. Finding 56.00 inches Code At least 60.00 inches ADA 4.8.4 odify or replace the landing to provide the minimum required ngth and width. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $2,872 $0.00 Record Number 30777 Ramp To City Owned Room West Entrance Run 1 Intermediate Landing The ramp changes direction at this landing. The length of the landing is less than the required minimum length. Finding 55.00 inches Code At least 60.00 inches ADA 4.8.4 "lodify or replace the landing to meet the minimum required idth and length. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set $2,600 $0.00 Record Number 30779 Ramp To City Owned Room West Entrance Run 1 Left Handrail The handrail extension is not parallel to the floor or ground surface. Finding Not Parallel ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 Provide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond ie bottom of the ramp and return smoothly to the post or wall. riority Four esolution Not Set 'rogress Not_Started assignment Not Set $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 10 of 853 Record Number 30780 Ramp To City Owned Room West Entrance Run 2 Right Handrail The handrail extension is not parallel to the floor or ground surface. Finding Not Parallel ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,400 $0.00 Record Number 30781 Ramp To City Owned Room West Entrance Run 2 Left Handrail The handrail extension is not parallel to the floor or ground surface. Finding Not Parallel ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Four .esolution Not Set rogress Not_Started Assignment Not Set $2,400 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30695 Stairs To Community Room Entrance Run 1 The striping on each tread of the stairway is not at a compliant width. Finding None Found ADA 4.9.5, CA 11B-504.4.1 rovide compliant striping on each tread of the stairway. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $460 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 11 of 853 Record Number 30694 Stairs To Community Room Entrance Run 1 There is no intermediate handrail available; the width of the stairway requires that a middle handrail is installed. Finding None Found rovide an intermediate handrail spaced equally in the middle of le stair run. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $1,528 $0.00 Record Number 30696 Stairs To Community Room Entrance Run 1 Left Handrail The gripping surface of the handrail is interrupted. Finding Interrupted ADA 4.9.4(4) Demount the handrail so is not interrupted. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $1,840 $0.00 Record Number 30697 Stairs To Community Room Entrance Run 1 Right Handrail The gripping surface of the handrail is interrupted. Finding Interrupted ADA 4.9.4(4) Demount the handrail so is not interrupted. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $1,840 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 12 of 853 Record Number 30611 Exterior Entrance To Kitchen Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 22.00 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance for the door. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set $2,921 $0.00 Record Number 30612 Exterior Entrance To Kitchen Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 39.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 Provide the recommended clear floor space on the pull side of 'ie door. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set $2,921 $0.00 Record Number 30609 Exterior Entrance To Kitchen Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Seven .esolution Not Set 'regress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 13 of 853 Record Number 30610 Exterior Entrance To Kitchen The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 30614 Main Entrance Next To Reception Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Record Number 30613 Main Entrance Next To Reception Push Bar / Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 14 of 853 Record Number 30615 Kitchen Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30617 Exterior Entrance To Game Room Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Record Number 30618 Exterior Entrance To Game Room The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 15 of 853 Record Number 30621 Right Door To Exercise Room Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30629 Learning Center Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30630 Door Between Staff Office & Game Room Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 16 of 853 Record Number 30636 Womens Restroom Next To Community Room Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30650 Health Center Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30658 Left Door To Exercise Room Push / Pull The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 17 of 853 Record Number 30659 Entrance Next To Computer Room Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set $400 $0.00 Record Number 30660 Entrance Next To Computer Room The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "lodify or replace the threshold to provide the recommended eight. tiority Four esolution Not Set 'rogress Not_Started assignment Not Set $436 $0.00 Record Number 30662 Door To Teen Room From Gymnasium Push / Pull The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. tiority Two esolution Not Set 'rogress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 18 of 853 Record Number 30688 Exterior Entrance To Arts & Crafts Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set rogress Not_Started Assignment Not Set $400 $0.00 Record Number 30687 Exterior Entrance To Arts & Crafts Push Bar / Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two esolution Not Set rogress Not_Started Assignment Not Set $25 $0.00 Record Number 30690 Door Between Gymnasium & Girls Locker Room Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 49.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 provide the recommended clear floor space on the pull side of le door. riority Six esolution Not Set rogress Not_Started _.ssignment Not Set $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 19 of 853 Record Number 30689 Door Between Gymnasium & Girls Locker Room Push / Pull The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30691 Door Between Gymnasium & Boys Locker Room Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30700 Exterior Door Next To Exercise Room Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 20 of 853 Record Number 30699 Exterior Door Next To Exercise Room Push Bar / Lever The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30701 Exterior Door Next To Exercise Room The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 30708 South Exterior Door To Gymnasium Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 21 of 853 Record Number 30707 South Exterior Door To Gymnasium Push Bar / Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30712 Mens Restroom Next To Community Room Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 30715 North Exterior Door To Gymnasium Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 22 of 853 Record Number 30716 North Exterior Door To Gymnasium Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set $50 $0.00 Record Number 30717 North Exterior Door To Gymnasium The height of the threshold at the entrance door is greater than allowed for a vertical rise. Finding 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $257 $0.00 Record Number 30718 Door Between Game Room & Boys Locker Room Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 23 of 853 Record Number 30722 Door Between Reception & Game Room The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 9.50 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $2,000 $0.00 Record Number 30723 Door Between Computer Room & Small Computer Room There is less than the required clearance between the two doors in a series. Finding 22.25 inches Code At least 48.00 inches ADA 4.13.7 Remove the inner door in a series to provide an accessible ntrance. riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set $48 $0.00 Record Number 30733 Door To Offices From Main Lobby Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force requirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 24 of 853 Record Number 30735 Exterior Entrance To Community Room Off Park Avenue Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $400 $0.00 Record Number 30764 Board Room Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two esolution Not Set rogress Not_Started Assignment Not Set $25 $0.00 Record Number 30789 Gate To Exterior Entrance To Kitchen Push Side There is not enough clear floor space provided at the push side of the door . Finding 28.00 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 'rovide the recommended clear floor space on the push side of le door. riority Seven esolution Not Set 'rogress Not_Started _.ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 25 of 853 Record Number 30788 Gate To Exterior Entrance To Kitchen The height of the threshold at the entrance door is greater than allowed for a vertical rise. Finding 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $257 $0.00 Record Number 30787 Gate To Exterior Entrance To Kitchen Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Record Number 30808 Door To Teen Room Next To Exercise Room Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $25 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 26 of 853 Record Number 30762 Kitchen Window The height of the counter or desk does not comply with height requirements. Finding 41.62 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Six .esolution Not Set rogress Not_Started _,ssignment Not Set $3,500 $0.00 Record Number 30763 Kitchen Window The counter is a protruding object. Finding See Above ADA 4.32.4, ADA 7.2 Hdjust the counter so that it is no longer a protruding object. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $450 $0.00 Record Number 30792 Reception Window Next To Game Room The height of the counter or desk does not comply with height requirements. Finding 40.00 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Six .esolution Not Set rogress Not_Started Assignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 27 of 853 Record Number 30793 Reception Window Next To Game Room The counter is a protruding object. Finding See Above ADA 4.32.4, ADA 7.2 djust the counter so that it is no longer a protruding object. riority Six .esolution Not Set rogress Not_Started Assignment Not Set $450 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30571 Path Of Travel From The Public Right Of Way Off Park Avenue Next To NE Entrance There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Record Number 30551 Arts & Crafts There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 Tnstall compliant room identification signage. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 28 of 853 Record Number 30572 Door Between Staff Office & Game Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30573 Board Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30616 Door To Teen Room Next To Exercise Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 29 of 853 Record Number 30619 Exterior Entrance To Game Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30622 Exterior Door Next To Exercise Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30635 Community Room There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 install accessible room signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 30 of 853 Record Number 30651 Health Center There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30652 Computer Room There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30653 Door Between Computer Room & Small Computer Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 31 of 853 Record Number 30657 Left Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30661 Gate To Exterior Entrance To Kitchen There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30669 Hallway Door To Staff Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. priority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 32 of 853 Record Number 30686 Learning Center There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30692 Door To Offices From Main Lobby There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30693 Door Between Board Room And Offices There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 33 of 853 Record Number 30698 Right Door To Exercise Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30714 Right Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30734 Exterior Entrance To Kitchen There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 34 of 853 Record Number 30736 Reception Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30737 Exterior Entrance To Community Room Off Park Avenue There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30738 Door Between Learning Center & Small Computer Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 35 of 853 Record Number 30759 North Exterior Door To Gymnasium There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30760 Entrance Next To Computer Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30761 South Exterior Door To Gymnasium There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 36 of 853 Record Number 30765 Left Door To Exercise Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30774 Door To Teen Room From Gymnasium There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30782 Kitchen There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 37 of 853 Record Number 30791 Exterior Entrance To Arts & Crafts There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30795 Gymnasium The accessible element/identification signage attached to the wall does not include Braille characters. Finding None Found ADA 4.30.4, CA 11B-703.3 (stall accessible signage to include Grade 2 Braille characters. riority Three .esolution Not Set 'rogress Not_Started ,assignment Not Set $50 $0.00 Record Number 30796 Gymnasium The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 67.75 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 38 of 853 Record Number 30794 Gymnasium Braille is not located below the raised letters. Finding None Found ADA 4.4.2, CA 11B-703.3.2 ake sure that braille is located below the raised letters. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30797 Main Entrance Next To Reception There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30809 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 39 of 853 Record Number 30812 City Owned Room West Entrance There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30557 Girls Locker Room Restroom The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 ' ower the mirror so the bottom edge of the reflective surface is 3 higher than recommended above the finished floor. riority Four esolution Not Set rogress Not_Started ..ssignment Not Set $300 $0.00 Record Number 30558 Girls Locker Room Restroom Female The gender use signage on the entrance door is not mounted at the required height. Finding 60.25 inches Code 60.00 inches CA 11B-703.7.2.6 nest gender use signage on the center of the door at the quired height. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 40 of 853 Record Number 30560 Girls Locker Room Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three .esolution Not Set rogress Not_Started _,ssignment Not Set $158 $0.00 Record Number 30559 Girls Locker Room Restroom Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Record Number 30556 Girls Locker Room Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 41 of 853 Record Number 30553 Girls Locker Room Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.25 inches Code At least 29.00 inches CA 11B-306.3.3, CA 118-606.2 aise or replace the lavatory to provide the minimum required iron height. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30554 Girls Locker Room Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,286 $0.00 Record Number 30555 Girls Locker Room Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set rogress Not_Started assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 42 of 853 Record Number 30561 Girls Locker Room Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three esolution Not Set rogress Not_Started _,ssignment Not Set $158 $0.00 Record Number 30552 Girls Locker Room Restroom Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Six esolution Not Set 'rogress Not_Started ,ssignment Not Set $277 $0.00 Record Number 30566 Boys Locker Room Restroom The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 Lower the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 43 of 853 Record Number 30562 Boys Locker Room Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.75 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required iron height. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30563 Boys Locker Room Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.50 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,286 $0.00 Record Number 30564 Boys Locker Room Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set rogress Not_Started assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 44 of 853 Record Number 30565 Boys Locker Room Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 30569 Boys Locker Room Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30567 Boys Locker Room Restroom Male The gender use signage on the entrance door is not mounted at the required height. Finding 59.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the . equired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 45 of 853 Record Number 30568 Boys Locker Room Restroom Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 3st gender use signage on the center of the door at the ?quired height. tiority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $158 $0.00 Record Number 30570 Boys Locker Room Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. tiority Three .esolution Not Set 'regress Not_Started ,assignment Not Set $158 $0.00 Record Number 30574 Mens Restroom Next To Community Room The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Six .esolution Not Set 'regress Not_Started Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 46 of 853 Record Number 30575 Mens Restroom Next To Community Room The entrance door swings into the turning space within the restroom. Finding 44.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $8,200 $0.00 Record Number 30582 Mens Restroom Next To Community Room The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 I ower the mirror so the bottom edge of the reflective surface is i to higher than recommended above the finished floor. riority Seven .esolution Not Set 'rogress Not_Started _,ssignment Not Set $300 $0.00 Record Number 30583 Mens Restroom Next To Community Room The top of the mirror is not at the compliant height. Finding 73.25 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 47 of 853 Record Number 30578 Mens Restroom Next To Community Room Lavatory The apron height under the lavatory is less than the required minimum height. Finding 27.75 inches Code At least 29.00 inches CA 11B-306.3.3, CA 118-606.2 aise or replace the lavatory to provide the minimum required iron height. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30579 Mens Restroom Next To Community Room Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.75 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,286 $0.00 Record Number 30580 Mens Restroom Next To Community Room Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set rogress Not_Started assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 48 of 853 Record Number 30581 Mens Restroom Next To Community Room Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 30585 Mens Restroom Next To Community Room There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 30584 Mens Restroom Next To Community Room Male The gender use signage on the entrance door is not mounted at the required height. Finding 59.75 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 49 of 853 Record Number 30576 Mens Restroom Next To Community Room Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Record Number 30577 Mens Restroom Next To Community Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Record Number 30637 Womens Restroom Next To Community Room The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 Modify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 50 of 853 Record Number 30638 Womens Restroom Next To Community Room The entrance door swings into the turning space within the restroom. Finding 38.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $8,200 $0.00 Record Number 30644 Womens Restroom Next To Community Room The top of the mirror is not at the compliant height. Finding 73.25 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 30645 Womens Restroom Next To Community Room Female The gender use signage on the entrance door is not mounted at the required height. Finding 59.75 inches Code 60.00 inches CA 11B-703.7.2.6 Post gender use signage on the center of the door at the required height. riority Seven esolution Not Set 'rogress Not_Started ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 51 of 853 Record Number 30641 Womens Restroom Next To Community Room Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $1,286 $0.00 Record Number 30642 Womens Restroom Next To Community Room Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 16.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 °eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set rogress Not_Started assignment Not Set $2,500 $0.00 Record Number 30643 Womens Restroom Next To Community Room Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 52 of 853 Record Number 30646 Womens Restroom Next To Community Room There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three .esolution Not Set rogress Not_Started _,ssignment Not Set $158 $0.00 Record Number 30639 Womens Restroom Next To Community Room Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $277 $0.00 Record Number 30640 Womens Restroom Next To Community Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started _assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 53 of 853 Record Number 30667 Mens Restroom Next To Community Room The distance from the side wall to the rear grab bar is greater than allowed. Finding 7.00 inches Code Up to 6.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2 emount the rear grab bar at a compliant location. tiority Four .esolution Not Set rogress Not_Started _,ssignment Not Set $78 $0.00 Record Number 30665 Mens Restroom Next To Community Room The distance from the back wall to the front of the grab bar is less than required. Finding 48.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 30666 Mens Restroom Next To Community Room The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 19.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 54 of 853 Record Number 30668 Mens Restroom Next To Community Room The toilet paper dispenser is not mounted at the required height. Finding 15.25 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Record Number 30663 Mens Restroom Next To Community Room The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30671 Boys Locker Room Restroom The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 44.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 55 of 853 Record Number 30670 Boys Locker Room Restroom The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. tiority Three esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Record Number 30683 Boys Locker Room Restroom The coat hook is not mounted at the correct height. Finding 61.50 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 Mount the coat hook at the recommended height. tiority Three esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Record Number 30680 Boys Locker Room Restroom The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Provide an accessible handle mounted on the door of the )mpartment near the latch. tiority Three esolution Not Set rogress Not_Started .-ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 56 of 853 Record Number 30681 Boys Locker Room Restroom Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. priority Three .esolution Not Set rogress Not_Started Assignment Not Set $269 $0.00 Record Number 30682 Boys Locker Room Restroom The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $129 $0.00 Record Number 30678 Boys Locker Room Restroom The height of the side grab bar is not at the correct height. Finding 34.00 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 57 of 853 Record Number 30679 Boys Locker Room Restroom The grab bar on the rear wall is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 emount the rear grab bar in the compartment designated to a accessible so the height of the gripping surface is at the )rrect height. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $231 $0.00 Record Number 30676 Boys Locker Room Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 53.50 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 30677 Boys Locker Room Restroom The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 22.50 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 58 of 853 Record Number 30672 Boys Locker Room Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.37 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30674 Boys Locker Room Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30675 Boys Locker Room Restroom There is less than the required minimum space in front of the toilet. Finding 45.75 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. tiority Six .esolution Not Set rogress Not_Started Assignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 59 of 853 Record Number 30684 Boys Locker Room Restroom The toilet paper dispenser is not mounted at the required height. Finding 16.50 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Record Number 30702 Unisex Staff Restroom There are no grab bars. Finding None Found ADA 4.17.6, ADA 4.16.4, CA 11B-604.5 (stall the required grab bars in the toilet compartment. riority Four esolution Not Set rogress Not_Started Assignment Not Set $267 $0.00 Record Number 30705 Unisex Staff Restroom Feminine products disposal distance from front of the toilet is not compliant. Finding 14.00 inches Code Up to 12.00 inches rovide feminine products disposal at the required distance om front of the toilet. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 60 of 853 Record Number 30704 Unisex Staff Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 38.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30745 Unisex Staff Restroom The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $1,800 $0.00 Record Number 30744 Unisex Staff Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 Install a compliant privacy lock with occupancy indicator to the door. riority Seven .esolution Not Set 'rogress Not_Started .-ssignment Not Set $804 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 61 of 853 Record Number 30746 Unisex Staff Restroom The entrance door swings into the turning space within the restroom. Finding 34.75 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $8,200 $0.00 Record Number 30756 Unisex Staff Restroom The top of the mirror is not at the compliant height. Finding 72.00 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 30753 Unisex Staff Restroom Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 26.00 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 Relocate the lavatory to provide clear floor space. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,261 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 62 of 853 Record Number 30754 Unisex Staff Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 30755 Unisex Staff Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $149 $0.00 Record Number 30749 Unisex Staff Restroom Lavatory The lavatory is in an enclosed cabinet, thereby preventing an accessible forward approach. Finding Not Accessible ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306 Remove or modify the lavatory cabinet and provide a compliant lavatory. riority Seven .esolution Not Set rogress Not_Started .ssignment Not Set $420 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 63 of 853 Record Number 30750 Unisex Staff Restroom Lavatory The height of the counter surface is greater than allowed. Finding 34.62 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $1,286 $0.00 Record Number 30751 Unisex Staff Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 25.62 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $1,286 $0.00 Record Number 30752 Unisex Staff Restroom Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 14.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 64 of 853 Record Number 30758 Unisex Staff Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three .esolution Not Set rogress Not_Started _,ssignment Not Set $158 $0.00 Record Number 30757 Unisex Staff Restroom All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Record Number 30747 Unisex Staff Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 52.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Seven .esolution Not Set 'rogress Not_Started _assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 65 of 853 Record Number 30748 Unisex Staff Restroom Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $277 $0.00 Record Number 30767 Womens Restroom Next To Community Room The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 47.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Record Number 30766 Womens Restroom Next To Community Room The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 66 of 853 Record Number 30772 Womens Restroom Next To Community Room The distance from the side wall to the rear grab bar is greater than allowed. Finding 7.00 inches Code Up to 6.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2 emount the rear grab bar at a compliant location. tiority Four esolution Not Set rogress Not_Started _,ssignment Not Set $78 $0.00 Record Number 30770 Womens Restroom Next To Community Room The distance from the back wall to the front of the grab bar is less than required. Finding 48.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 30771 Womens Restroom Next To Community Room The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 19.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Six esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 67 of 853 Record Number 30773 Womens Restroom Next To Community Room The toilet paper dispenser is not mounted at the required height. Finding 15.25 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Record Number 30768 Womens Restroom Next To Community Room The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30806 Girls Locker Room Restroom The coat hook is not mounted at the correct height. Finding 61.75 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 68 of 853 Record Number 30803 Girls Locker Room Restroom The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. priority Three .esolution Not Set rogress Not_Started Assignment Not Set $250 $0.00 Record Number 30804 Girls Locker Room Restroom Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $269 $0.00 Record Number 30805 Girls Locker Room Restroom The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Adjust the inside handle so that it is located near the latch. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set $129 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 69 of 853 Record Number 30801 Girls Locker Room Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 48.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 30802 Girls Locker Room Restroom The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 20.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 30807 Girls Locker Room Restroom The toilet paper dispenser is not mounted at the required height. Finding 17.50 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser in the compartment to the required height. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 70 of 853 Record Number 30798 Girls Locker Room Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 30800 Girls Locker Room Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30655 Drinking Fountain Next To The Main Entrance There is less than the required minimum knee clearance height Finding 26.75 inches Code At least 27.00 inches ADA 4.15.5, CA 11B-602.2, CA 11B-306 rovide a fountain with the required knee and toe clearances. riority Six esolution Not Set 'rogress Not_Started .ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 71 of 853 Record Number 30656 Drinking Fountain Next To The Main Entrance The drinking fountain is not set entirely in an alcove. Finding None Found CA 11B-602.9 rovide compliant wing walls or barrier at the drinking fountain. riority Six esolution Not Set rogress Not_Started Assignment Not Set $640 $0.00 Record Number 30654 Drinking Fountain Next To The Main Entrance The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. riority Six esolution Not Set 'rogress Not_Started .ssignment Not Set $2,500 $0.00 Record Number 30592 Drinking Fountain In Gymnasium The height of the water stream is less than required. Finding 2.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 Adjust the flow of the water stream to a compliant height. °riority Three esolution Not Set rogress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 72 of 853 Record Number 30593 Drinking Fountain In Gymnasium There is not enough clear floor space width for a front approach to the drinking fountain. Finding 32.50 inches Code At least 36.00 inches ADA 4.2.4.2 rovide compliant clear floor space at the drinking fountain. riority Seven esolution Not Set rogress Not_Started _,ssignment Not Set $108 $0.00 Record Number 30594 Drinking Fountain In Gymnasium There is not enough clear floor space for a parallel approach in an alcove. Finding 55.00 inches Code At least 60.00 inches ADA 4.2.4.2, CA 11B-602.2, CA 11B-305.7.2 rovide the required clear floor space or reduce the depth of le alcove. tiority Six esolution Not Set 'rogress Not_Started Assignment Not Set $108 $0.00 Record Number 30591 Drinking Fountain In Gymnasium The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. tiority Six esolution Not Set 'rogress Not_Started .,ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 73 of 853 Record Number 30620 Drinking Fountain In Game Room eplace the drinking fountain with a compliant High/Low )untain. $2,500 $0.00 The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 riority Six .esolution Not Set rogress Not_Started .ssignment Not Set Assembly Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30713 Gymnasium There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 4.00 seats CA 11B-221.2, CA 11B-802.1 provide a compliant amount of accessible seats. riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set $600 $0.00 Locker Rooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30706 Boys Locker Room There are no accessible benches in the locker room. Finding None Found ADA 4.35.4, ADA 4.37 )stall compliant benches in the locker room. riority Six .esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 74 of 853 Record Number 30790 Girls Locker Room There are no accessible benches in the locker room. Finding None Found ADA 4.35.4, ADA 4.37 (stall compliant benches in the locker room. riority Six .esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30811 Visual Alarms There are visual warning devices provided throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 Since visual warning devices are provided in all areas of the icility, no additional action is required. Priority Six .esolution Not Set rogress Not_Started Assignment Not Set $0.00 Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30724 Board Room The table knee clearance does not meet required standards. Finding 26.75 inches Code At least 27.00 inches CA 11B-902.2, CA 11B-305, CA 11B-306 rovide compliant tables. riority Four .esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 75 of 853 Record Number 30725 Board Room The table knee width does not meet required standards. Finding 22.00 inches Code At least 30.00 inches ADA 4.27 rovide compliant tables. riority Four .esolution Not Set rogress Not_Started Assignment Not Set $2,174 $0.00 Record Number 30726 Board Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Two .esolution Not Set rogress Not_Started ,assignment Not Set $158 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30709 Kitchen Sink counter height is not compliant. Finding 35.75 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 "rovide compliant sink. riority Seven .esolution Not Set rogress Not_Started .ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 76 of 853 Record Number 30710 Kitchen The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect aainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $149 $0.00 Record Number 30711 Kitchen There is not enough clear floor space at the sink. Finding 47.00 inches Code At least 48.00 inches CA 11B-606.2 rovide enough clear floor space at the location. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $900 $0.00 Record Number 30727 Arts & Crafts Sink counter height is not compliant. Finding 36.00 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. °riority Six .esolution Not Set rogress Not_Started Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 77 of 853 Record Number 30728 Arts & Crafts The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set $420 $0.00 Record Number 30729 Arts & Crafts The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Record Number 30730 Arts & Crafts There is not enough clear floor space at the sink. Finding 44.00 inches Code At least 48.00 inches CA 11B-606.2 ovide enough clear floor space at the location. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $900 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 78 of 853 Record Number 30731 Arts & Crafts There is not enough clear floor space at the sink. Finding 29.00 inches Code At least 30.00 inches ADA 4.27 ,ovide enough clear floor space at the location. riority Six esolution Not Set rogress Not_Started Assignment Not Set $900 $0.00 Record Number 30732 Arts & Crafts Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set $180 $0.00 Record Number 30739 Health Center Sink counter height is not compliant. Finding 36.00 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 Provide compliant sink. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 79 of 853 Record Number 30740 Health Center The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set $420 $0.00 Record Number 30741 Health Center The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Record Number 30742 Health Center There is not enough clear floor space at the sink. Finding 29.50 inches Code At least 30.00 inches ADA 4.27 ovide enough clear floor space at the location. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $900 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 80 of 853 Record Number 30743 Health Center Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $180 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30685 Picnic Tables The required percentage of picnic tables provided are not accessible. Finding None Found Code At least 1.00 tables ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 provide a sufficient number of compliant picnic tables. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set $500 $0.00 Accessible Showers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30586 Girls Locker Room Shower There is no folding seat in the accessible shower. Finding No Seat ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant folding seat in the accessible shower. riority Six .esolution Not Set rogress Not_Started Assignment Not Set $1,068 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 81 of 853 Record Number 30588 Girls Locker Room Shower The grab bar is mounted on walls over the seat. Finding Over Seat ADA 4.21.4, CA 11B-609, CA 11B-608.3 ove the grab bar so that it is mounted on walls opposite and ijacent to the front edge of the seat, but not extended to 'elude that portion of wall over the seat. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,840 $0.00 Record Number 30587 Girls Locker Room Shower There is no hand-held sprayer unit in the shower designated to be accessible. Finding None Found ADA 4.21, ADA 4.21.6, CA 11B-608.6 rovide a compliant hand-held sprayer unit with a hose. riority Six esolution Not Set rogress Not_Started ,assignment Not Set $385 $0.00 Record Number 30589 Girls Locker Room Shower The operational force required to operate the water valve is not compliant Finding Not Accessible ADA 4.21.5, CA 11B-608.5, CA 11B-309.4 rovide an accessible water control device that can be operated ith one hand and a compliant pounds of force to operate. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $554 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 82 of 853 Record Number 30590 Girls Locker Room Shower The water valve distance from seat wall is not compliant. Finding 41.75 inches Code 18.00 - 24.00 inches ADA 4.21.5, CA 11B-608.5 rovide a compliant water valve. riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,500 $0.00 Record Number 30625 Boys Locker Room Shower Shower seat width is not compliant. Finding 14.37 inches Code 15.00 - 22.00 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant shower seat. riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,500 $0.00 Record Number 30626 Boys Locker Room Shower The distance between the folding seat and the adjacent wall is not compliant. Finding 1.75 inches Code Up to 1.50 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant shower seat. riority Seven esolution Not Set rogress Not_Started Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 83 of 853 Record Number 30624 Boys Locker Room Shower The grab bar is mounted on walls over the seat. Finding Over Seat ADA 4.21.4, CA 11B-609, CA 11B-608.3 ove the grab bar so that it is mounted on walls opposite and ijacent to the front edge of the seat, but not extended to 'elude that portion of wall over the seat. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,840 $0.00 Record Number 30623 Boys Locker Room Shower There is no hand-held sprayer unit in the shower designated to be accessible. Finding None Found ADA 4.21, ADA 4.21.6, CA 11B-608.6 rovide a compliant hand-held sprayer unit with a hose. riority Six esolution Not Set rogress Not_Started ,assignment Not Set $385 $0.00 Record Number 30627 Boys Locker Room Shower The operational force required to operate the water valve is not compliant Finding Not Accessible ADA 4.21.5, CA 11B-608.5, CA 11B-309.4 rovide an accessible water control device that can be operated ith one hand and a compliant pounds of force to operate. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $554 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 84 of 853 Record Number 30628 Boys Locker Room Shower The water valve distance from seat wall is not compliant. Finding 41.00 inches Code 18.00 - 24.00 inches ADA 4.21.5, CA 11B-608.5 rovide a compliant water valve. riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,500 $0.00 Record Number 30810 Shower In Unisex Staff Restroom There are not enough accessible showers with respect to the total number of showers available. Finding None Found Code At least 1.00 showers ADA 4.21.2, CA 11B-213.3.6 rovide the required amount of compliant accessible showers. riority Six esolution Not Set rogress Not_Started ,assignment Not Set $4,500 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30647 Community Room Powerade Vending Machine The forward reach height of the controls on the vending machine is greater than the allowed maximum height. Finding 52.25 inches Code Up to 48.00 inches ADA 4.2.5 ''ontact the owner of the vending machines to obtain accessible znding machines. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 85 of 853 Record Number 30648 Community Room Snack Vending Machine The forward reach height of the controls on the vending machine is greater than the allowed maximum height. Finding 52.75 inches Code Up to 48.00 inches ADA 4.2.5 ontact the owner of the vending machines to obtain accessible =nding machines. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $0.00 Record Number 30649 Community Room Snack Vending Machine The controls of the vending machine require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.2.5 °eplace controls of vending machine with those that allow oeration with one hand and does not require tight grasping, inching, or twisting of the wrist. riority Seven esolution Not Set rogress Not_Started ,ssignment Not Set $550 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 86 of 853 City Of La Quinta Sports Complex Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29565 Accessible Parking Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 103.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $350 $0.00 Record Number 29566 Accessible Parking Accessible Space The slope of the accessible parking space is not compliant. Finding 3.20 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. riority Seven .esolution Not Set 'regress Not_Started .assignment Not Set $3,800 $0.00 Record Number 29567 Accessible Parking Accessible Space The access aisle does not meet the minimum required width. Finding 91.00 inches Code At least 96.00 inches ADA 4.1.2(5) e-stripe the access aisle. riority Three .esolution Not Set 'regress Not_Started assignment Not Set $250 $0.00 Path of Travel Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 87 of 853 Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29537 Path Of Travel From The Public Right Of Way Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 2.60 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 rovide a compliant path of travel. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $3,600 $0.00 Record Number 29570 Path Of Travel To Baseball Fields Open Area The path of travel is grass, dirt, or gravel, preventing access to individuals with mobility impairments. Finding Dirt, Grass or Gravel ADA 4.5.1, CA 11B-302.1, CA 11B-403.2 Provide an accessible route. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set $1,840 $0.00 Record Number 29586 Path to Path Of Travel From The Accessible Space Crosswalk From The Access Aisle There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 rovide detectable warnings. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $190 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 88 of 853 Record Number 29609 rovide an intermediate handrail spaced equally in the middle of le stair run. $1,528 $0.00 Stairs To The Baseball Field Next To The Concession Stand Run 1 There is no intermediate handrail available; the width of the stairway requires that a middle handrail is installed. Finding None Found riority Four .esolution Not Set rogress Not_Started Assignment Not Set Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 27990 Concession Stand Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $0.00 Record Number 29571 Womens Restroom Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 89 of 853 Record Number 29577 Main Office Pull Side There is no level landing at this door. Finding 2.90 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. tiority Seven .esolution Not Set 'rogress Not_Started assignment Not Set $1,500 $0.00 Record Number 29576 Main Office The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 29574 Main Office Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 lstall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. Priority Four .esolution Corrected 'rogress Completed ,ssignment Not Set 12/15/2015 $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 90 of 853 Record Number 29573 Main Office Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 12/15/2015 $25 $0.00 Record Number 29575 Main Office Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Corrected 'rogress Completed Assignment Not Set 12/15/2015 $50 $0.00 Record Number 29606 Mens Restroom Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed .ssignment Not Set 12/15/2015 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 91 of 853 Record Number 29607 Mens Restroom Push / Pull Door hardware is not mounted at the correct height. Finding 48.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Three esolution Corrected 'rogress Completed assignment Not Set 12/15/2015 $280 $0.00 Record Number 29608 Mens Restroom The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 28805 South Mens Restroom The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 92 of 853 Record Number 28806 Gate To Baseball Field On The North Side Of The Concession Stand Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. tiority Four .esolution Corrected 'rogress Completed ,ssignment Not Set 12/15/2015 $400 $0.00 Record Number 28809 Gate To The Baseball Field On South Side Of The Concession Stand Push Side There is no level landing at this door. Finding 99.00 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. tiority Five .esolution Corrected 'rogress Completed assignment Not Set 12/15/2015 $1,500 $0.00 Record Number 28807 Gate To The Baseball Field On South Side Of The Concession Stand Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Install a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. Priority Four .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 93 of 853 Record Number 28808 Gate To The Baseball Field On South Side Of The Concession Stand The height of the threshold at the entrance door is greater than allowed. Finding 3.50 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four .esolution Corrected 'rogress Completed Assignment Not Set 12/15/2015 $436 $0.00 Record Number 28835 South Womens Restroom The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 Modify or replace the threshold to provide the recommended i leight. riority Four .esolution Not Set 'rogress Not_Started _,ssignment Not Set $436 $0.00 Record Number 28844 Mens Restroom Next To Concession Stand The height of the threshold at the entrance door is greater than allowed for a vertical rise. Finding 0.50 inches ADA 4.13.8, CA 11B-404.2.5 Modify or replace the threshold to provide the recommended neight. riority Seven .esolution Not Set 'rogress Not_Started .-ssignment Not Set $257 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 94 of 853 Record Number 27401 Gate To Baseball Field D Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 55.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $2,921 $0.00 Record Number 27400 Gate To Baseball Field D Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Tnstall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Corrected 'rogress Completed .ssignment Not Set 12/15/2015 $400 $0.00 Record Number 27434 Gate To Fields 2 And 3 Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Install a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 95 of 853 Record Number 27435 Gate To Fields 2 And 3 odify or replace the threshold to provide the recommended eight. 12/15/2015 $436 $0.00 The height of the threshold at the entrance door is greater than allowed. Finding 2.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11 B-404.2. 5 °riority Four .esolution Corrected rogress Completed Assignment Not Set Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29605 Food Counter At Concession Stand The height of the counter or desk does not comply with height requirements. Finding 34.50 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set $3,500 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29548 Main Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 )stall compliant room identification signage. riority Three .esolution Corrected 'rogress Completed Assignment Not Set 12/15/2015 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 96 of 853 Record Number 27402 Concession Stand There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $158 $0.00 Record Number 28911 Directional Signage From The Public Right Of Way To The Concession Area There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Not Set 'rogress Not_Started ,assignment Not Set $158 $0.00 Record Number 29856 Directional Signage To The Baseball Fields There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 install directional signage to each accessible element or room. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 97 of 853 Record Number 29539 Mens Restroom The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 57.00 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $1,707 $0.00 Record Number 29547 Mens Restroom The height of the side grab bar is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Record Number 29545 Mens Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 49.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 98 of 853 Record Number 29546 Mens Restroom The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 20.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 29541 Mens Restroom The height of the toilet seat is not at the required height. Finding 15.00 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 Adjust or modify the toilet so the seat height is at the required :cessible height. tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $1,707 $0.00 Record Number 29540 Mens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.00 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. tiority Five .esolution Not Set 'rogress Not_Started .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 99 of 853 Record Number 29543 Mens Restroom The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $127 $0.00 Record Number 29544 Mens Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 37.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Five .esolution Not Set 'rogress Not_Started _,ssignment Not Set $2,500 $0.00 Record Number 29578 Womens Restroom The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 56.00 inches Code At least 60.00 inches ADA 4.16.2 Provide a compliant clearance around the water closet measured perpendicular from the rear wall. tiority Five .esolution Not Set 'rogress Not_Started .-ssignment Not Set $1,707 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 100 of 853 Record Number 29584 Womens Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 48.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. priority Three esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 29585 Womens Restroom The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 19.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Three esolution Corrected 'rogress Completed Assignment Not Set 12/15/2015 $267 $0.00 Record Number 29582 Womens Restroom The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 Relocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $127 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 101 of 853 Record Number 29583 Womens Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 38.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Five .esolution Not Set 'regress Not_Started Assignment Not Set $2,500 $0.00 Record Number 29580 Womens Restroom The height of the toilet seat is not at the required height. Finding 16.00 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. riority Five .esolution Not Set 'regress Not_Started .ssignment Not Set $1,707 $0.00 Record Number 29579 Womens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven .esolution Not Set 'regress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 102 of 853 Record Number 29588 Womens Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. tiority Five .esolution Not Set 'regress Not_Started Assignment Not Set $1,286 $0.00 Record Number 29589 Womens Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 °rovide compliant signage on latch side of door. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 29587 Womens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 49.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 ^elocate the dispenser to the correct height. tiority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 103 of 853 Record Number 29593 Mens Restroom The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. priority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $280 $0.00 Record Number 29597 Mens Restroom The height of the urinal rim in the restroom is not compliant. Finding 17.25 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 Lower the urinal designated to be accessible in the restroom so iat the rim height is compliant. riority Five .esolution Not Set 'regress Not_Started assignment Not Set $1,397 $0.00 Record Number 29598 Mens Restroom The height of the urinal flush control in the restroom is greater than the required maximum height. Finding 34.00 inches Code At least 44.00 inches ADA 4.18.4, CA 11B-605.4 Lower the flush control valve on the urinal to a height not reater than the required maximum height. riority Five .esolution Not Set 'regress Not_Started .ssignment Not Set $227 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 104 of 853 Record Number 29596 Mens Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.25 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $1,286 $0.00 Record Number 29600 Mens Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 °rovide compliant signage on latch side of door. riority Three .esolution Corrected 'rogress Completed Assignment Not Set 12/15/2015 $158 $0.00 Record Number 29599 Mens Restroom Male The gender use signage on the entrance door is not mounted at the required height. Finding 59.50 inches Code 60.00 inches CA 11B-703.7.2.6 'lost gender use signage on the center of the door at the quired height. riority Three .esolution Corrected 'rogress Completed _.ssignment Not Set 12/15/2015 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 105 of 853 Record Number 29594 Mens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 50.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Three .esolution Corrected 'rogress Completed ,ssignment Not Set 12/15/2015 $277 $0.00 Record Number 29595 Mens Restroom Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Three .esolution Corrected 'rogress Completed ,ssignment Not Set 12/15/2015 $277 $0.00 Record Number 28813 South Womens Restroom Female The gender use signage on the entrance door is not mounted at the required height. Finding 61.00 inches Code 60.00 inches CA 11B-703.7.2.6 Post gender use signage on the center of the door at the ?quired height. Priority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 106 of 853 Record Number 28812 South Womens Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 28814 South Womens Restroom The signage is not mounted at the required height. Finding 61.00 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. tiority Seven .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 28811 South Womens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Three .esolution Corrected 'rogress Completed assignment Not Set 12/15/2015 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 107 of 853 Record Number 28817 South Mens Restroom The height of the urinal flush control in the restroom is greater than the required maximum height. Finding 43.00 inches Code At least 44.00 inches ADA 4.18.4, CA 11B-605.4 )wer the flush control valve on the urinal to a height not reater than the required maximum height. priority Three esolution Not Set 'rogress Not_Started Assignment Not Set $227 $0.00 Record Number 28818 South Mens Restroom The urinal in the restroom does not provide a tapered, elongated rim. Finding Not Tapered ADA 4.18.2 eplace the urinal designated to be accessible in the restroom ith a wall -mounted or compartment -type tapered, elongated m unit. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $951 $0.00 Record Number 28820 South Mens Restroom The signage is not mounted at the required height. Finding 61.00 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 post compliant signage at the restroom. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 108 of 853 Record Number 28819 South Mens Restroom Male The gender use signage on the entrance door is not mounted at the required height. Finding 61.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 28816 South Mens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 °elocate the dispenser to the correct height. Priority Three .esolution Corrected 'rogress Completed Assignment Not Set 12/15/2015 $277 $0.00 Record Number 28840 Mens Restroom Next To The Concession Stand The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 ^elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. tiority Three .esolution Corrected 'rogress Completed ssignment Not Set 12/15/2015 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 109 of 853 Record Number 28843 Mens Restroom Next To The Concession Stand The coat hook is not mounted at the correct height. Finding 53.00 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Three esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $50 $0.00 Record Number 28842 Mens Restroom Next To The Concession Stand The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Three esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 28875 Womens Restroom Next To The Concession Stand The signage is not mounted at the required height. Finding 60.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Dst compliant signage at the restroom. °riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 110 of 853 Record Number 28873 Womens Restroom Next To The Concession Stand Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Record Number 28874 Womens Restroom Next To The Concession Stand Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Record Number 28877 South Mens Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Five .esolution Not Set 'regress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 111 of 853 Record Number 28887 South Womens Restroom The height of the side grab bar is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Record Number 28888 South Womens Restroom The grab bar on the rear wall is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $231 $0.00 Record Number 28891 Mens Restroom Next To The Concession Stand The height of the urinal flush control in the restroom is greater than the required maximum height. Finding 43.00 inches Code At least 44.00 inches ADA 4.18.4, CA 11B-605.4 )wer the flush control valve on the urinal to a height not reater than the required maximum height. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $227 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 112 of 853 Record Number 28892 Mens Restroom Next To The Concession Stand The urinal in the restroom does not provide a tapered, elongated rim. Finding Not Tapered ADA 4.18.2 eplace the urinal designated to be accessible in the restroom ith a wall -mounted or compartment -type tapered, elongated m unit. tiority Five .esolution Not Set rogress Not_Started Assignment Not Set $951 $0.00 Record Number 28893 Mens Restroom Next To The Concession Stand Male The gender use signage on the entrance door is not mounted at the required height. Finding 60.50 inches Code 60.00 inches CA 11B-703.7.2.6 Post gender use signage on the center of the door at the quired height. tiority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set $158 $0.00 Record Number 28894 Mens Restroom Next To The Concession Stand The signage is not mounted at the required height. Finding 60.50 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Dst compliant signage at the restroom. tiority Three .esolution Not Set 'regress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 113 of 853 Record Number 28890 Mens Restroom Next To The Concession Stand Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Record Number 28896 Womens Restroom Next To The Concession Stand The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 45.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $277 $0.00 Record Number 28900 Womens Restroom Next To The Concession Stand The coat hook is not mounted at the correct height. Finding 53.00 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 Mount the coat hook at the recommended height. riority Three .esolution Not Set 'regress Not_Started .ssignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 114 of 853 Record Number 28899 Womens Restroom Next To The Concession Stand The grab bar on the rear wall is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $231 $0.00 Record Number 28898 Womens Restroom Next To The Concession Stand The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 34.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28838 Drinking Fountain Next To The Concession Entrance Drinking fountain does not provide a required fountain depth. Finding 12.00 inches Code At least 15.00 inches ADA 4.15.5, CA 11B-602.8 Install a drinking fountain the meets the required minimum 2pth. Priority Five esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 115 of 853 Record Number 28837 Drinking Fountain Next To The Concession Entrance The spout outlet height is greater than required. Finding 39.00 inches Code Up to 36.00 inches ADA 4.15.2, CA 11B-602.4 rovide a spout outlet that does not exceed the required height. riority Five .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $627 $0.00 Record Number 28839 Drinking Fountain Next To The Concession Entrance The drinking fountain is not set entirely in an alcove. Finding None Found CA 11B-602.9 rovide compliant wing walls or barrier at the drinking fountain. riority Five .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $640 $0.00 Record Number 28836 Drinking Fountain Next To The Concession Entrance The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. riority Five .esolution Corrected 'rogress Completed .,ssignment Not Set 12/15/2015 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 116 of 853 Record Number 27367 Drinking Fountain Between Baseball Fields 1 And 2 The spout outlet height is greater than required. Finding 37.00 inches Code Up to 36.00 inches ADA 4.15.2, CA 11B-602.4 rovide a spout outlet that does not exceed the required height. riority Five esolution Not Set rogress Not_Started Assignment Not Set $627 $0.00 Record Number 27368 Drinking Fountain Between Baseball Fields 1 And 2 The distance from the front edge of the unit (including bumpers) to the spout location, is greater than the allowed maximum distance. Finding 7.00 inches Code Up to 6.00 inches ADA 4.15.3, CA 11B-602.5 rovide a fountain with the spout location a compliant distance om the front of the fountain to the flow of the water. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 27365 Drinking Fountain Between Baseball Fields 1 And 2 The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 Replace the drinking fountain with a compliant High/Low fountain. riority Five esolution Not Set rogress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 117 of 853 Record Number 27366 Drinking Fountain Between Baseball Fields 1 And 2 The drinking fountain is not on accessible route. Finding None Found ADA 4.15.5 ake sure the drinking fountain is on an accessible route. riority Five esolution Not Set rogress Not_Started Assignment Not Set $1,840 $0.00 Record Number 28909 Drinking Fountain Next To The Concession Office Drinking fountain does not provide a required fountain depth. Finding 12.00 inches Code At least 15.00 inches ADA 4.15.5, CA 11B-602.8 (stall a drinking fountain the meets the required minimum epth. riority Five esolution Corrected 'rogress Completed .ssignment Not Set 12/15/2015 $2,500 $0.00 Record Number 28906 Drinking Fountain Next To The Concession Office The spout outlet height is greater than required. Finding 40.00 inches Code Up to 36.00 inches ADA 4.15.2, CA 11B-602.4 Provide a spout outlet that does not exceed the required height. °riority Five esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $627 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 118 of 853 Record Number 28907 Drinking Fountain Next To The Concession Office The height of the water stream is less than required. Finding 3.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 djust the flow of the water stream to a compliant height. riority Five .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $2,500 $0.00 Record Number 28910 Drinking Fountain Next To The Concession Office The drinking fountain is not set entirely in an alcove. Finding None Found CA 11B-602.9 rovide compliant wing walls or barrier at the drinking fountain. riority Five .esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $640 $0.00 Record Number 28904 Drinking Fountain Next To The Concession Office The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. tiority Three .esolution Corrected 'rogress Completed .,ssignment Not Set 12/15/2015 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 119 of 853 Record Number 28905 Drinking Fountain Next To The Concession Office The drinking fountain is a protruding object. Finding None ADA 4.15.5, CA 11B-602, CA 11B-307.2 ake sure that the fountain is not a protruding object. riority Five esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $550 $0.00 Record Number 28908 Drinking Fountain Next To The Concession Office The clear floor space slope is not compliant. Finding 2.90 percent Code Up to 2.00 percent ADA 4.15.5, CA 11B-602.2 rovide compliant clear floor space at the drinking fountain. riority Seven esolution Corrected rogress Completed Assignment Not Set 12/15/2015 $2,200 $0.00 Assembly Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29538 Upper Baseball Field There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 2.00 seats CA 11B-221.2, CA 11B-802.1 rovide a compliant amount of accessible seats. riority Five .esolution Not Set rogress Not_Started ,ssignment Not Set $600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 120 of 853 Record Number 29569 Lower Baseball Field There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 4.00 seats CA 11B-221.2, CA 11B-802.1 rovide a compliant amount of accessible seats. riority Five esolution Not Set rogress Not_Started _,ssignment Not Set $600 $0.00 Record Number 27418 Baseball Field 2 There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 4.00 seats CA 11B-221.2, CA 11B-802.1 rovide a compliant amount of accessible seats. riority Five esolution Not Set rogress Not_Started ,assignment Not Set $600 $0.00 Record Number 27471 Baseball Field D There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 2.00 seats CA 11B-221.2, CA 11B-802.1 Provide a compliant amount of accessible seats. riority Five esolution Not Set rogress Not_Started Assignment Not Set $600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 121 of 853 Record Number 27473 Baseball Field 5 There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 4.00 seats CA 11B-221.2, CA 11B-802.1 rovide a compliant amount of accessible seats. riority Five .esolution Not Set rogress Not_Started _,ssignment Not Set $600 $0.00 Record Number 27474 Baseball Field 3 There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 4.00 seats CA 11B-221.2, CA 11B-802.1 rovide a compliant amount of accessible seats. riority Five .esolution Not Set rogress Not_Started ,assignment Not Set $600 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28810 South Womens Restroom There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 Install visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Six .esolution Not Set rogress Not_Started ,assignment Not Set $2,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 122 of 853 Record Number 28815 South Mens Restroom There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $2,200 $0.00 Record Number 28872 Womens Restroom Next To The Concession Stand There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $2,200 $0.00 Record Number 28889 Mens Restroom Next To The Concession Stand There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $2,200 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 123 of 853 Record Number 28864 Sink In The Concession Stand Sink counter height is not compliant. Finding 35.50 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Five esolution Not Set rogress Not_Started Assignment Not Set $1,800 $0.00 Record Number 28865 Sink In The Concession Stand The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Four esolution Not Set rogress Not_Started Assignment Not Set $420 $0.00 Record Number 28866 Sink In The Concession Stand The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 124 of 853 Record Number 28867 Sink In The Concession Stand Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set $180 $0.00 Record Number 28868 Sink In The Concession Stand Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set $180 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 27977 Picnic Tables Next To The South Restrooms No ISA Symbol was found at the picnic table. Finding None Found ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 Add a compliant ISA symbol at the picnic table. riority Three .esolution Not Set rogress Not_Started .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 125 of 853 Record Number 28895 Picnic Tables In Front Of The Concession Stand No ISA Symbol was found at the picnic table. Finding None Found ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 dd a compliant ISA symbol at the picnic table. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 27303 Benches Next To Harry S. Truman Elementary School The bench back rest height is not compliant. Finding 12.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 djust the bench back rest height to recommended value. riority Four .esolution Corrected rogress Completed ,ssignment Not Set 12/15/2015 $800 $0.00 Record Number 27369 Benches At The Batting Cages The bench back rest height is not compliant. Finding 12.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 ^,djust the bench back rest height to recommended value. riority Four .esolution Corrected rogress Completed .ssignment Not Set 12/15/2015 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 126 of 853 Civic Center Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43043 Employees Parking Lot Parking Lot Warning Sign Signage height from the finished floor is not compliant. Finding 28.37 inches Code At least 36.00 inches CA 11B-502.8 rovide compliant signage at a compliant height. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $110 $0.00 Record Number 43015 Employees Parking Lot 1st Row Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 101.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43016 Employees Parking Lot 1st Row Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 127 of 853 Record Number 43017 Employees Parking Lot 1st Row Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43018 Employees Parking Lot 1st Row Left Accessible Space The height of the wall -mounted signage at the accessible space is not compliant. Finding 28.25 inches Code At least 36.00 inches ADA 4.6.4, CA 11B-502.6 Demount the wall -mounted signage at the accessible parking Jace at a compliant height. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43019 Employees Parking Lot 3rd Row Right Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 101.87 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 Re -stripe the accessible parking space. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 128 of 853 Record Number 43020 Employees Parking Lot 3rd Row Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43021 Employees Parking Lot 3rd Row Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43023 Employees Parking Lot 2nd Row Right Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 102.25 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 129 of 853 Record Number 43024 Employees Parking Lot 2nd Row Right Accessible Space The accessible parking space does not meet the minimum requirement for length. Finding 194.00 inches Code At least 216.00 inches CA 11B-502.2 e-stripe the accessible parking space. tiority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43022 Employees Parking Lot 2nd Row Right Accessible Space The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 Re -stripe the existing parking space marked as accessible to 'efine the width of the space. tiority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43025 Employees Parking Lot 2nd Row Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. tiority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 130 of 853 Record Number 43027 Employees Parking Lot 2nd Row Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43026 Employees Parking Lot 2nd Row Right Accessible Space ISA surface identification is faded and not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.6.4 Repaint the ISA surface identification in the parking space. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $117 $0.00 Record Number 43028 Employees Parking Lot 2nd Row Right Accessible Space The height of the wall -mounted signage at the accessible space is not compliant. Finding 28.00 inches Code At least 36.00 inches ADA 4.6.4, CA 11B-502.6 Demount the wall -mounted signage at the accessible parking Jace at a compliant height. riority Seven .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 131 of 853 Record Number 43029 Employees Parking Lot 2nd Row Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 101.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43030 Employees Parking Lot 2nd Row Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the lternational Symbol of Accessibility. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43032 Employees Parking Lot 2nd Row Left Accessible Space The height of the wall -mounted signage at the accessible space is not compliant. Finding 28.50 inches Code At least 36.00 inches ADA 4.6.4, CA 11B-502.6 emount the wall -mounted signage at the accessible parking Jace at a compliant height. Priority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 132 of 853 Record Number 43031 Employees Parking Lot 2nd Row Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 48.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. tiority Seven .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43033 Employees Parking Lot 2nd Row Left Accessible Space The access aisle does not meet the minimum required width. Finding 95.75 inches Code At least 96.00 inches ADA 4.1.2(5) De -stripe the access aisle. tiority Seven .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43034 Employees Parking Lot 2nd Row Left Accessible Space The access aisle markings are faded, damaged, or otherwise not viewable. Finding None Found CA 11B-502.3 De -stripe the access aisle so as to discourage parking. tiority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 133 of 853 Record Number 43035 Employees Parking Lot 1st Row Right Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 107.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43036 Employees Parking Lot 1st Row Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the lternational Symbol of Accessibility. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43038 Employees Parking Lot 1st Row Right Accessible Space The designated accessible parking space does not provide accessible signage at the head of the space. Finding None Found ADA 4.6.4 Provide compliant sigange at the accessible space. riority Seven .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 134 of 853 Record Number 43039 Employees Parking Lot 1st Row Right Accessible Space The height of the wall -mounted signage at the accessible space is not compliant. Finding 28.75 inches Code At least 36.00 inches ADA 4.6.4, CA 11B-502.6 emount the wall -mounted signage at the accessible parking Jace at a compliant height. tiority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43037 Employees Parking Lot 1st Row Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 48.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 °rovide compliant surface identification at the accessible parking Dace. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43040 Employees Parking Lot 3rd Row Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 101.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 Re -stripe the accessible parking space. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 135 of 853 Record Number 43041 Employees Parking Lot 3rd Row Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43042 Employees Parking Lot 3rd Row Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 48.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43073 Visitors Parking Lot There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Three .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 136 of 853 Record Number 43074 Visitors Parking Lot South Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 105.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43075 Visitors Parking Lot South Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the lternational Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43076 Visitors Parking Lot South Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. Priority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 137 of 853 Record Number 43077 Visitors Parking Lot South Accessible Space The height of the wall -mounted signage at the accessible space is not compliant. Finding 17.00 inches Code At least 36.00 inches ADA 4.6.4, CA 11B-502.6 emount the wall -mounted signage at the accessible parking Jace at a compliant height. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43078 Visitors Parking Lot South Accessible Space The access aisle does not meet the minimum required width. Finding 92.00 inches Code At least 96.00 inches ADA 4.1.2(5) De -stripe the access aisle. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43079 Visitors Parking Lot South Accessible Space The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. Finding None Found CA 11B-502.3.3 paint the words "NO PARKING" a compliant height within the :cess aisle. tiority Three .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 138 of 853 Record Number 43080 Visitors Parking Lot North Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 103.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43081 Visitors Parking Lot North Accessible Space The accessible parking space does not meet the minimum requirement for length. Finding 215.75 inches Code At least 216.00 inches CA 11B-502.2 Re -stripe the accessible parking space. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43082 Visitors Parking Lot North Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 139 of 853 Record Number 43086 Visitors Parking Lot North Accessible Space The access aisle does not meet the minimum required width. Finding 92.25 inches Code At least 96.00 inches ADA 4.1.2(5) e-stripe the access aisle. tiority Three .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $250 $0.00 Record Number 43088 Visitors Parking Lot North Accessible Space The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. Finding None Found CA 11B-502.3.3 aint the words "NO PARKING' a compliant height within the :cess aisle. tiority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Record Number 43085 Visitors Parking Lot North Accessible Space The access aisle is not located on the passenger side of the parking space. Finding See Above ADA 4.6.3 rovide a compliant access aisle on the passenger side of the :cessible parking space. tiority Three .esolution Not Set 'rogress Not_Started ..ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 140 of 853 Record Number 43084 Visitors Parking Lot North Accessible Space The height of the wall -mounted signage at the accessible space is not compliant. Finding 16.37 inches Code At least 36.00 inches ADA 4.6.4, CA 11B-502.6 emount the wall -mounted signage at the accessible parking Jace at a compliant height. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43083 Visitors Parking Lot North Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 °rovide compliant surface identification at the accessible parking Dace. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $220 $0.00 Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43146 Curb Ramp From The Employee Parking Lot The running slope is greater than allowed. Finding 10.10 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 °rovide a compliant curb ramp. riority Four .esolution Not Set rogress Not_Started ssignment Not Set 06/30/2013 $1,s,.. $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 141 of 853 Record Number 43253 1st Curb Ramp On Path Of Travel From Washington Street The running slope is greater than allowed. Finding 9.30 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 rovide a compliant curb ramp. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43254 1st Curb Ramp On Path Of Travel From Washington Street The cross slope is greater than allowed. Finding 3.00 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.7 rovide a compliant curb ramp. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43256 1st Curb Ramp On Path Of Travel From Washington Street Bottom Landing The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. Finding Not Beveled ADA 4.5.2, CA 11B-406.5.8 atch the transition area at the bottom of the curb ramp so that le transition is flush and free of abrupt changes. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $255 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 142 of 853 Record Number 43255 1st Curb Ramp On Path Of Travel From Washington Street Bottom Landing The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. Finding 0.50 inches Code Up to 0.25 inches ADA 4.5.2, ADA 406.5.8 atch the transition area at the bottom of the curb ramp so that le transition is flush and free of abrupt changes. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $255 $0.00 Record Number 43257 1st Curb Ramp On Path Of Travel From Washington Street Top Landing The transition from the top of the curb ramp to the walk, gutter, or street is abrupt. Finding 0.62 inches Code Up to 0.50 inches ADA 4.5.2, CA 11B-406.5.6 °atch the transition area at the top of the curb ramp so that the ansition is flush and free of abrupt changes. riority Four .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $155 $0.00 Record Number 43295 2nd Curb Ramp On Path Of Travel From Washington Street Bottom Landing The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. Finding Not Beveled ADA 4.5.2, CA 11B-406.5.8 Patch the transition area at the bottom of the curb ramp so that He transition is flush and free of abrupt changes. riority Not Set .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $255 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 143 of 853 Record Number 43294 atch the transition area at the bottom of the curb ramp so that le transition is flush and free of abrupt changes. 06/30/2013 $255 $0.00 2nd Curb Ramp On Path Of Travel From Washington Street Bottom Landing The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. Finding 0.50 inches Code Up to 0.25 inches ADA 4.5.2, ADA 406.5.8 riority Four .esolution Not Set rogress Not_Started Assignment Not Set Record Number 43296 2nd Curb Ramp On Path Of Travel From Washington Street Top Landing The slope at the top landing is greater than allowed. Finding 2.60 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.3 °rovide a top landing that has a compliant slope and ianeuvering space. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,260 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43429 Path Of Travel Near EOC Stretcher The leading edge of the item protrudes into the circulation route greater than permitted. Finding 9.37 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 (stall side extensions, modify, relocate, or lower the item so 'at it is not a protruding object into the circulation route. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $64G $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 144 of 853 Record Number 42968 Path Of Travel At The Entrances Floor Mats The mats or carpet runners do not adhere to the underlying floor surface and slip, thereby creating a hazardous path of travel. Finding Not Accessible ADA 4.5.3, CA 11B-403.2, CA 11B-302 ecurely fasten the mats or carpet runners or replace with a la or carpet runner that grips to the underlying floor surface provide a firm, stable, and slip resistant path of travel. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $42 $0.00 Record Number 42987 Path Of Travel From Calle Tampico Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 5.80 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 Provide a compliant path of travel. tiority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $3,600 $0.00 Record Number 43046 Path Of Travel From The Accessible Spaces In The Visitors Lot Path Of Travel From The Access Aisle There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 Provide detectable warnings. tiority Three .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 145 of 853 Record Number 43047 Path Of Travel From The Accessible Spaces In The Visitors Lot Path Of Travel From The Access Aisle The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 rovide a compliant crosswalk. tiority Three esolution Not Set togress Not_Started assignment Not Set 06/30/2013 $1,100 $0.00 Record Number 43176 Path Of Travel From Washington Street Path Of Travel Crosses Traffic The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 rovide a compliant crosswalk. tiority Three esolution Not Set togress Not_Started Assignment Not Set 06/30/2013 $1,100 $0.00 Record Number 43319 Path Of Travel To The Area 5 South Entrance Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 6.40 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 Provide a compliant path of travel. tiority Five esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 146 of 853 Record Number 42985 Path Of Travel To The Planning Department Fire Extinguisher The leading edge of the item protrudes into the circulation route greater than permitted. Finding 4.50 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 (stall side extensions, modify, relocate, or lower the item so 'at it is not a protruding object into the circulation route. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $640 $0.00 Record Number 43008 Path Of Travel In Hallway 155 Automated External Defibrillator The leading edge of the item protrudes into the circulation route greater than permitted. Finding 5.25 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 Tnstall side extensions, modify, relocate, or lower the item so lat it is not a protruding object into the circulation route. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $640 $0.00 Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43065 Ramp From Calle Tampico Run 1 The ramp run does not provide adequate edge protection to prevent individuals from slipping off the ramp. Finding None Found ADA 4.8.7, CA 11B-405.9 Tnstall compliant edge protection on each side of the ramp run. Priority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 .)-+iu $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 147 of 853 Record Number 43066 Ramp From Calle Tampico Run 1 Bottom Landing The slope of the landing is greater than required. Finding 5.00 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-405.7.1 odify the landing to create a slope in any direction not Kceeding the required maximum value. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,872 $0.00 Record Number 43069 Ramp From Calle Tampico Run 1 Right Handrail The height of the handrail on the ramp is not a compliant height above the surface of the ramp. Finding 33.75 inches Code 34.00 - 38.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.4 odify or replace the handrail on the ramp to provide a )mpliant gripping surface height. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $3,918 $0.00 Record Number 43068 Ramp From Calle Tampico Run 1 Right Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Five esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 148 of 853 Record Number 43067 Ramp From Calle Tampico Run 1 Right Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. tiority Five esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,400 $0.00 Record Number 43071 Ramp From Calle Tampico Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,400 $0.00 Record Number 43070 Ramp From Calle Tampico Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 provide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond ie bottom of the ramp and return smoothly to the post or wall. 4riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 149 of 853 Record Number 43222 Ramp To The Area 4 Patio Run 1 The slope of the ramp is greater than the allowed slope. Finding 8.60 percent Code Up to 8.33 percent ADA 4.8.2, CA 11B-405.2 odify the run of the ramp to provide the required slope and -oss slope. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $3,600 $0.00 Record Number 43223 Ramp To The Area 4 Patio Run 2 Top Landing The length of the top landing does not meet the required minimum length. Finding 48.50 inches Code At least 60.00 inches CA 11B-405.7.3 odify or replace the top landing to provide the required iinimum length and width. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,872 $0.00 Record Number 43224 Ramp To The Area 4 Patio Run 2 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. Finding 9.50 inches Code At least 12.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 150 of 853 Record Number 43230 Ramp At The South Entrance To The Lobby Run 1 The ramp run does not provide adequate edge protection to prevent individuals from slipping off the ramp. Finding None Found ADA 4.8.7, CA 11B-405.9 (stall compliant edge protection on each side of the ramp run. tiority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $470 $0.00 Record Number 43231 Ramp At The South Entrance To The Lobby Run 1 Bottom Landing The slope of the landing is greater than required. Finding 3.30 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-405.7.1 Modify the landing to create a slope in any direction not xceeding the required maximum value. riority Five .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $2,872 $0.00 Record Number 43234 Ramp At The South Entrance To The Lobby Run 1 Left Handrail The height of the handrail on the ramp is not a compliant height above the surface of the ramp. Finding 33.75 inches Code 34.00 - 38.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.4 odify or replace the handrail on the ramp to provide a )mpliant gripping surface height. Priority Five .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $3,918 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 151 of 853 Record Number 43232 Ramp At The South Entrance To The Lobby Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Five esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,400 $0.00 Record Number 43233 Ramp At The South Entrance To The Lobby Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. Finding 11.00 inches Code At least 12.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Five .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,400 $0.00 Record Number 43236 Ramp At The South Entrance To The Lobby Run 1 Right Handrail The height of the handrail on the ramp is not a compliant height above the surface of the ramp. Finding 33.50 inches Code 34.00 - 38.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.4 Modify or replace the handrail on the ramp to provide a compliant gripping surface height. riority Five .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $3,918 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 152 of 853 Record Number 43235 Ramp At The South Entrance To The Lobby Run 1 Right Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. tiority Five esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,400 $0.00 Record Number 43237 Ramp To EOC/Police 151 Run 1 The ramp run does not provide adequate edge protection to prevent individuals from slipping off the ramp. Finding None Found ADA 4.8.7, CA 11B-405.9 Install compliant edge protection on each side of the ramp run. tiority Five .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $470 $0.00 Record Number 43238 Ramp To EOC/Police 151 Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. Finding 11.50 inches Code At least 12.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 Provide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. Priority Five .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 153 of 853 Record Number 43240 Ramp To EOC/Police 151 Run 1 Right Handrail The surface of the wall adjacent to the handrail is abrasive. Finding Abrasive ADA 4.26.4 odify the surface of the wall adjacent to the handrail so that le surface is smooth and nonabrasive. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,320 $0.00 Record Number 43239 Ramp To EOC/Police 151 Run 1 Right Handrail There is not enough handrail extension beyond the top or bottom of the rail. Finding 11.50 inches Code At least 12.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,400 $0.00 Record Number 43244 Ramp To The Study Session Room Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. Priority Five esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 154 of 853 Record Number 43245 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. 06/30/2013 $2,400 $0.00 Ramp To The Study Session Room Run 1 Right Handrail There is not enough handrail extension beyond the top or bottom of the rail. ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 riority Five .esolution Not Set rogress Not_Started ..ssignment Not Set Elevators Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43392 Area 5 Elevator There is no signage at the elevator indicating the evacuation plan. Finding None Found ADA 4.10 "rovide compliant signage indicating evacuation plan and )utes. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $207 $0.00 Record Number 43393 Area 5 Elevator The main entrance floor is not identified with a star to the left of the control button. Finding Not Accessible ADA 4.10.12, CA 11B-407.4.7.1.3 ,ontact a certified elevator provider to perform all renovation quired. riority Four esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 155 of 853 Record Number 43394 Area 5 Elevator The reopening device for the elevator door does not remain open for the required amount of time. Finding Not Accessible ADA 4.10.6, CA 11B-407.3.3.3 ontact a certified elevator provider to perform all renovation ?quired. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Record Number 43395 Area 5 Elevator Elevator communication control mounting height is not compliant. Finding 31.37 inches Code 35.00 - 48.00 inches ADA 4.10.14, CA 11B-308, CA 11B-407.4.9 °rovide communication controls at a compliant height. Contact a certified elevator provider to perform all renovation required. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,200 $0.00 Record Number 43396 Area 5 Elevator The hoistway signage is not at a compliant height above the finished floor. Finding 59.87 inches on center Code 60.00 inches on center ADA 4.10.5, CA 11B-407.2.3.1 'rovide compliant signage within the elevator hoistways. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 156 of 853 Record Number 43397 Area 5 Elevator Braille is not located immediately below the raised letters. Finding None Found ADA 4.10.5 rovide compliant signage that has the braille located imediately below the raised letters. riority Four esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43398 Area 5 Elevator Main floor is not indicated with a star. Finding None Found ADA 4.10.5 ake sure that main floor is indicated with a star. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $180 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43433 Stairwell Near The Elevator Run 2 Left Handrail The top handrail extension is not the required length beyond the top riser. Finding 11.25 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 Tnstall a compliant handrail extension to the top of the handrail iat extends beyond the top riser and is parallel to the floor arface of the landing. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 157 of 853 Record Number 43434 Stairwell Near The Elevator Run 2 Right Handrail The top handrail extension is not the required length beyond the top riser. Finding 8.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 (stall a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Record Number 43435 Stairwell Near The Elevator Run 2 Right Handrail The bottom handrail does not extend the depth of one stair tread beyond the bottom step. Finding None Found ADA 4.9.4(2), CA 11B-505.10.3 Provide a compliant handrail extension. tiority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $1,425 $0.00 Record Number 43436 Stairwell Near The Elevator Run 1 The stair striping is not at a compliant distance from the nosing. Finding 1.87 inches Code At least 2.00 inches ADA 4.9.5, CA 11B-504.4.1 Affix compliant contrasting striping to the upper approach and ach tread that is the correct width and distance from the Dsing. tiority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $460 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 158 of 853 Record Number 43437 Stairwell Near The Elevator Run 1 Left Handrail The top handrail extension is not the required length beyond the top riser. Finding 10.50 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 (stall a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. tiority Four esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Record Number 43212 Southwest Stairs Run 1 The striping on each tread of the stairway is not at a compliant width. Finding 1.25 inches Code Up to 1.00 inches ADA 4.9.5, CA 11B-504.4.1 Provide compliant striping on each tread of the stairway. tiority Three esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $460 $0.00 Record Number 43213 Southwest Stairs Run 1 Right Handrail The handrail extension is not the required length. Finding 4.50 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.3 Install a compliant extension to the handrail. tiority Four esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $627 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 159 of 853 Record Number 43251 Stairs To Receiving 154 Run 1 Left Handrail The handrail is not mounted at the required height. Finding 32.00 inches Code 34.00 - 38.00 inches ADA 4.9.4(5), CA 11B-504.6, CA 11B-505 rovide handrail at the required height. tiority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $1,528 $0.00 Record Number 43250 Stairs To Receiving 154 Run 1 Left Handrail The top handrail extension is not the required length beyond the top riser. Finding 5.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 (stall a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Record Number 43252 Stairs To Receiving 154 Run 1 Right Handrail The top handrail extension is not the required length beyond the top riser. Finding 3.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 )stall a compliant handrail extension to the top of the handrail lat extends beyond the top riser and is parallel to the floor arface of the landing. Priority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 160 of 853 Record Number 43259 Stairs To The Area 4 Patio Run 1 There is no intermediate handrail available; the width of the stairway requires that a middle handrail is installed. Finding None Found rovide an intermediate handrail spaced equally in the middle of le stair run. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,528 $0.00 Record Number 43186 Left Stairs In The Council Chambers 101 Run 1 The width of the stairway does not meet the minimum required width. Finding 41.50 inches Code At least 44.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 Tnstall a stairway with a minimum width as required. Priority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $4,816 $0.00 Record Number 43187 Left Stairs In The Council Chambers 101 Run 1 There is no detectable striping on the stairways. Finding None Found ADA 4.9.5, CA 11B-504.4.1 "ffix compliant contrasting striping to the upper approach and ach tread that is the correct width and distance from the Dsing. riority Three .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $1,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 161 of 853 Record Number 43188 Left Stairs In The Council Chambers 101 Run 1 Left Handrail The top handrail extension is not the required length beyond the top riser. Finding 7.25 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 (stall a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Record Number 43274 Right Stairs In The Council Chambers 101 Run 1 The width of the stairway does not meet the minimum required width. Finding 42.25 inches Code At least 44.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 Install a stairway with a minimum width as required. riority Six .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $4,816 $0.00 Record Number 43275 Right Stairs In The Council Chambers 101 Run 1 There is no detectable striping on the stairways. Finding None Found ADA 4.9.5, CA 11B-504.4.1 Affix compliant contrasting striping to the upper approach and ach tread that is the correct width and distance from the Dsing. riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $1,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 162 of 853 Record Number 43422 West Stairwell Run 1 The width of the stairway does not meet the minimum required width. Finding 43.00 inches Code At least 44.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 (stall a stairway with a minimum width as required. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $4,816 $0.00 Record Number 43423 West Stairwell Run 1 Left Handrail The surface texture of the wall adjacent to the handrail is sharp and abrasive. Finding Near Wall ADA 4.26.4 Modify the surface texture on the wall adjacent to the handrail D that the surface is smooth. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,320 $0.00 Record Number 43424 West Stairwell Run 2 The width of the stairway does not meet the minimum required width. Finding 43.00 inches Code At least 44.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 )stall a stairway with a minimum width as required. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $4,816 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 163 of 853 Record Number 43425 West Stairwell Run 2 The stair striping is not at a compliant distance from the nosing. Finding 1.87 inches Code At least 2.00 inches ADA 4.9.5, CA 11B-504.4.1 ffix compliant contrasting striping to the upper approach and 3ch tread that is the correct width and distance from the Dsing. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $460 $0.00 Record Number 43426 West Stairwell Run 2 Right Handrail The top handrail extension is not the required length beyond the top riser. Finding 5.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 Tnstall a compliant handrail extension to the top of the handrail lat extends beyond the top riser and is parallel to the floor arface of the landing. riority Four .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43386 Basement Stairwell Door Near EOC Push Bar / Lever The door opening force for this door is greater than allowed. Finding 13.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 164 of 853 Record Number 43409 EOC Mens & Womens Restroom Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43413 EOC Staff Lounge Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43414 EOC Staff Lounge Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 165 of 853 Record Number 43419 EOC Push Bar / Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43420 EOC Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 42991 Exterior Doors From The Courtyard Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 166 of 853 Record Number 43101 New Addition Area 1 Exterior Door Pull Side There is no level landing at this door. Finding 2.90 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. tiority Four esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43100 New Addition Area 1 Exterior Door The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Record Number 43099 New Addition Area 1 Exterior Door Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. tiority Two esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 167 of 853 Record Number 43104 Exterior Door To Receiving 154 The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Record Number 43102 Exterior Door To Receiving 154 Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43103 Exterior Door To Receiving 154 Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 168 of 853 Record Number 43123 Main Lobby South Entrance Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 38.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43122 Main Lobby South Entrance Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 °emove the door stop. tiority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43159 Exterior Door To The Council Chambers Push / Pull The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. tiority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 169 of 853 Record Number 43178 Exterior Doors To The Area 4 Patio Pull Side There is no level landing at this door. Finding 2.80 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. tiority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43177 Exterior Doors To The Area 4 Patio Push Bar / Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43219 Exterior Door Near The Computer Room 141 There is no specific signage for the automatic door. Finding No Signage ANSI/BHMA A156.19, ADA 404 Provide compliant caution automatic door signage. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 170 of 853 Record Number 43220 Exterior Door Near The Computer Room 141 The automatic door does not hold open for the minimum required time. Finding See Above ANSI/BHMA A156.19, ADA 404 djust the automatic door so the force to stop the door from osing is no more than allowed. priority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43221 Exterior Door Near The Computer Room 141 There is no level landing at this Automatic door. Finding 2.50 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing for the automatic door. riority Five .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,040 $0.00 Record Number 43268 East Entrance To The Area 4 Sessions Room Push Bar / Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 171 of 853 Record Number 43269 East Entrance To The Area 4 Sessions Room Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Record Number 43273 Staff Lounge 180 Patio Pull Side There is no level landing at this door. Finding 3.10 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43271 Staff Lounge 180 Patio Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 172 of 853 Record Number 43272 Staff Lounge 180 Patio Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Record Number 43341 North Entrance To The West Lobby Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43342 South Employee Entrance To The West Lobby Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 15.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 173 of 853 Record Number 43343 South Employee Entrance To The West Lobby Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Record Number 43356 Exterior Doors Near The Mayors Office Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 12.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43357 Exterior Doors Near The Mayors Office The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 174 of 853 Record Number 42948 Mens Locker Room 176 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 16.75 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $4,000 $0.00 Record Number 42947 Mens Locker Room 176 Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Record Number 42967 Hallway Door To EOC/Police 151 Push Side There is less than the required latch side clearance on the push side of the door. Finding 0.62 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 nrovide the recommended latch side clearance on the push side F the door. riority Five .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 175 of 853 Record Number 42965 Hallway Door To EOC/Police 151 Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 42966 Hallway Door To EOC/Police 151 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 42977 Doors In The New Addition Area 1 Engineer Offices Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 176 of 853 Record Number 42982 Mens Staff Restroom 177 & Womens Staff Restroom 179 Push Side There is not enough clear floor space provided at the push side of the door . Finding 47.00 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $4,000 $0.00 Record Number 42981 Mens Staff Restroom 177 & Womens Staff Restroom 179 Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Record Number 42983 Door From Public Works 200 To The New Addition Area 1 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 11.50 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide required latch side clearance on the pull side of the Dor. riority Seven .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 177 of 853 Record Number 42986 Hallway Doors Near Plan Checker 162 & Parks 170 Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Record Number 42988 South Conference Room 138, East Conference Room 167, & North Conference Room 190 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 52.25 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. riority Five .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $2,921 $0.00 Record Number 42989 Mens Lobby Restroom 130 Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force . equirements. riority Two .esolution Not Set rogress Not_Started ..ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 178 of 853 Record Number 42990 Mens Lobby Restroom 130 Push / Pull Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. tiority Three esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $280 $0.00 Record Number 43007 Rear Hallway Door To The Production Office 183 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 14.50 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. tiority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43004 Rear Hallway Door To The Production Office 183 Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Four esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 179 of 853 Record Number 43005 Rear Hallway Door To The Production Office 183 Single Knob The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43006 Rear Hallway Door To The Production Office 183 Single Knob Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43011 Hallway Door 155 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 12.75 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 180 of 853 Record Number 43009 Hallway Door 155 Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43010 Hallway Door 155 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Corrected 'rogress Completed Assignment Not Set 02/27/2012 02/27/2012 $50 $0.00 Record Number 43012 Doorway From The Lobby To The Finance Counters The clear opening width of the door is less than required. Finding 31.25 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Seven .esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 181 of 853 Record Number 43013 Doorway From The Lobby To The Finance Counters Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 lstall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $400 $0.00 Record Number 43014 Swinging Gates Near The Service Counters Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Tnstall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $400 $0.00 Record Number 43051 Door Between Mens Locker Room 176 & Restroom 177 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 58.25 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 Provide the recommended clear floor space on the pull side of He door. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 182 of 853 Record Number 43050 Door Between Mens Locker Room 176 & Restroom 177 Push / Pull Door hardware is not mounted at the correct height. Finding 44.25 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. tiority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $280 $0.00 Record Number 43062 Womens Lobby Restroom 131 Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43063 Womens Lobby Restroom 131 Push / Pull Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 Mount the door hardware at the recommended height. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 183 of 853 Record Number 43064 Door Between Womens Locker Room 178 & Restroom 179 Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43089 Hallway Door To Receiving 154 Lever The door opening force for this door is greater than allowed. Finding 15.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43090 Hallway Door To Receiving 154 Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 184 of 853 Record Number 43117 Accessible Showers In The Mens & Womens Locker Rooms 176 & 178 The vertical clearance height of the door is less than required. Finding 67.62 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 tend the height of the doorway to provide the required earance height. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,000 $0.00 Record Number 43120 Accessible Showers In The Mens & Womens Locker Rooms 176 & 178 Push Side There is not enough clear floor space provided at the push side of the door . Finding 46.12 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43119 Accessible Showers In The Mens & Womens Locker Rooms 176 & 178 The height of the threshold at the entrance door is greater than allowed for a vertical rise. Finding 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended 1 Ieight. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $257 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 185 of 853 Record Number 43118 Accessible Showers In The Mens & Womens Locker Rooms 176 & 178 Finger Pull - 1.5 The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Record Number 43134 Door Between Recieving 154 & EOC/Police 151 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 10.00 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 Provide required latch side clearance on the pull side of the ' Dor. tiority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43136 Front Door To The Production Office 183 Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 186 of 853 Record Number 43137 Front Door To The Production Office 183 Single Knob Door hardware is not mounted at the correct height. Finding 46.25 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. tiority Three .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $280 $0.00 Record Number 43179 Main Office Production Room Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43181 Womens Locker Room 178 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 16.75 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 187 of 853 Record Number 43180 Womens Locker Room 178 Push / Pull Door hardware is not mounted at the correct height. Finding 58.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. tiority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $280 $0.00 Record Number 43190 Exercise Room Near The Staff Lounge The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Record Number 43189 Exercise Room Near The Staff Lounge Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. tiority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 188 of 853 Record Number 43193 Door From The Main Lobby To The West Wing Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $400 $0.00 Record Number 43194 Caucus Room Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 2.12 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 °rovide required latch side clearance on the pull side of the Dor. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43195 Main Office Lever The door opening force for this door is greater than allowed. Finding 13.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force quirements. riority Two esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 189 of 853 Record Number 43196 Main Office Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. tiority Two .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Record Number 43210 Area 4 Session Room Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43211 Area 4 Session Room Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. tiority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 190 of 853 Record Number 43214 Lobby Door To The Council Chambers 101 Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43215 Lobby Door To The Council Chambers 101 Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43227 Rear Door To The Council Chambers 101 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 44.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the pull side of le door. Priority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 191 of 853 Record Number 43226 Rear Door To The Council Chambers 101 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Record Number 43225 Rear Door To The Council Chambers 101 Lever Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $280 $0.00 Record Number 43242 Council Chambers 101 Audio Visual Room Push Side There is less than the required latch side clearance on the push side of the door. Finding 5.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. Priority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 192 of 853 Record Number 43243 Council Chambers 101 Audio Visual Room Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 23.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the pull side of le door. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43241 Council Chambers 101 Audio Visual Room Lever Has a door stop. Finding Found CA 11B-404.2.10 °emove the door stop. tiority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43246 Main Office Computer Room Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 7.25 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide required latch side clearance on the pull side of the Dor. tiority Five .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 193 of 853 Record Number 43249 Hallway Door Near The Main Lobby South Entrance Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 17.12 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43248 Hallway Door Near The Main Lobby South Entrance Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 °emove the door stop. tiority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43247 Hallway Door Near The Main Lobby South Entrance Push Bar / D Handle Door hardware is not mounted at the correct height. Finding 44.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 "'bunt the door hardware at the recommended height. tiority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 194 of 853 Record Number 43258 Production Room 146 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 47.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43264 Offices 132A & B Push Side There is not enough clear floor space provided at the push side of the door . Finding 47.75 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 °rovide the recommended clear floor space on the push side of le door. riority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43265 Offices 132A & B Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 42.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 Provide the recommended clear floor space on the pull side of He door. riority Five .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 195 of 853 Record Number 43266 Staff Lounge 180 Lever The door opening force for this door is greater than allowed. Finding 12.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43293 Office Near Womens Restroom 111 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 2.75 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43299 Mens & Womens Restrooms In Area 4 Sessions Room Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 196 of 853 Record Number 43324 Hallway Door From The Main lobby To The City Mangers Office Push Bar / Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Record Number 43325 Hallway Door From The Main lobby To The City Mangers Office Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 °emove the door stop. Priority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43330 Hallway Door Near The Area 5 Police Office Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 9.75 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide required latch side clearance on the pull side of the Dor. riority Five .esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 197 of 853 Record Number 43345 Hallway Door Near Womens Restroom 111 Push Side There is less than the required latch side clearance on the push side of the door. Finding 6.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43346 Hallway Door Near Womens Restroom 111 Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 5.00 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 °rovide required latch side clearance on the pull side of the Dor. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43344 Hallway Door Near Womens Restroom 111 Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force quirements. riority Two esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 198 of 853 Record Number 43355 Mens & Womens Restrooms In The West Lobby Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43379 Hallway Door To The City Managers Marketing Offices Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43380 Hallway Door To The City Managers Marketing Offices Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 199 of 853 Record Number 43408 Stairwell Door Near The Elevator Push Side There is less than the required latch side clearance on the push side of the door. Finding 5.12 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43406 Stairwell Door Near The Elevator Push / Pull The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Record Number 43407 Stairwell Door Near The Elevator Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 ^emove the door stop. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 200 of 853 Record Number 43415 Exterior Stairwell Door Near The Elevator Push Bar / Lever The door opening force for this door is greater than allowed. Finding 10.50 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43416 Exterior Stairwell Door Near The Elevator Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43417 Exterior Stairwell Door Near The Elevator The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 201 of 853 Record Number 43349 Mayors Reception Counter The height of the counter or desk does not comply with height requirements. Finding 41.87 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Three .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $3,500 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 42984 Exterior Doors From The Courtyard There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 Tnstall compliant room identification signage. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43121 North & South Entrances To The Lobby There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 Tnstall accessible room signage. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 202 of 853 Record Number 43135 Directional Signage From The Public Right Of Way There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43045 Room Identification Signage There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43132 EOC/Police 151 The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 59.87 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 203 of 853 Record Number 43270 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. 06/30/2013 $50 $0.00 Caucus Room The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 59.87 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 riority Three .esolution Not Set rogress Not_Started .assignment Not Set Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43383 EOC Womens Restroom The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43384 EOC Womens Restroom The door to the compartment swings inward into the minimum required compartment area. Finding Swings In ADA 4.17.3, CA 11B-604.8.1 odify the swing of the door so that it does not swing into the iinimum required compartment area. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 204 of 853 Record Number 43385 EOC Womens Restroom The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 15.00 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43381 EOC Womens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.87 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43403 EOC Mens Restroom The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 205 of 853 Record Number 43404 EOC Mens Restroom Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Record Number 43405 EOC Mens Restroom The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43401 EOC Mens Restroom The height of the side grab bar is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. priority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 206 of 853 Record Number 43402 EOC Mens Restroom The grab bar on the rear wall is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Record Number 43399 EOC Mens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43428 EOC Mens Restroom The urinal does not meet the requirement for the minimum projection from the back wall to the front of the urinal rim. Finding 13.50 inches Code At least 14.00 inches ADA 4.18.2, CA 11B-605.2 (stall a urinal that meets the minimum projection ?quirements. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $951 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 207 of 853 Record Number 43427 EOC Mens Restroom The top of the mirror is not at the compliant height. Finding 73.75 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43431 EOC Womens Restroom The top of the mirror is not at the compliant height. Finding 73.37 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43430 EOC Womens Restroom Lavatory The height of the counter surface is greater than allowed. Finding 34.25 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 208 of 853 Record Number 43432 EOC Womens Restroom Female The gender use signage on the entrance door is not mounted at the required height. Finding 60.25 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Seven .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 42953 Mens Staff Restroom 177 The shields extend greater than 24" in front of the urinal. The width between the shields is less than required. Finding 35.50 inches Code At least 36.00 inches ADA 4.18.2, CA 11B-605.3, CA 11B-305.7 "lodify or replace the urinal shields in the restroom to provide le required clearance between the shields for the urinal esignated as accessible. riority Six .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $1,800 $0.00 Record Number 42951 Mens Staff Restroom 177 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.75 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set _ 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 209 of 853 Record Number 42952 Mens Staff Restroom 177 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $149 $0.00 Record Number 42955 Mens Staff Restroom 177 The signage is not mounted at the required height. Finding 59.87 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 42956 Mens Staff Restroom 177 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 )stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 210 of 853 Record Number 42954 Mens Staff Restroom 177 Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 42950 Mens Staff Restroom 177 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 42962 Mens Staff Restroom 177 The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Provide an accessible handle mounted on the door of the )mpartment near the latch. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 211 of 853 Record Number 42963 Mens Staff Restroom 177 Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. priority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Record Number 42964 Mens Staff Restroom 177 The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 42960 Mens Staff Restroom 177 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 212 of 853 Record Number 42969 Womens Lobby Restroom 131 There is insufficient clear floor space in the compartment. Finding 59.75 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 odify or replace the compartment to provide adequate clear Dor space. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 42973 Womens Lobby Restroom 131 The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 42974 Womens Lobby Restroom 131 The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Adjust the inside handle so that it is located near the latch. °riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 213 of 853 Record Number 42970 Womens Lobby Restroom 131 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 42972 Womens Lobby Restroom 131 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.25 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 42993 Mens Lobby Restroom 130 There is insufficient clear floor space in the compartment. Finding 59.50 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 odify or replace the compartment to provide adequate clear Dor space. riority Seven .esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 214 of 853 Record Number 42997 Mens Lobby Restroom 130 The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. priority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 42998 Mens Lobby Restroom 130 Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Record Number 42999 Mens Lobby Restroom 130 The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Adjust the inside handle so that it is located near the latch. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 215 of 853 Record Number 43000 Mens Lobby Restroom 130 The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 16.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. priority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 42994 Mens Lobby Restroom 130 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 42996 Mens Lobby Restroom 130 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 216 of 853 Record Number 43057 Womens Staff Restroom 179 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43058 Womens Staff Restroom 179 Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43059 Womens Staff Restroom 179 The signage is not mounted at the required height. Finding 59.87 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 217 of 853 Record Number 43060 Womens Staff Restroom 179 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43055 Womens Staff Restroom 179 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43056 Womens Staff Restroom 179 Feminine Products The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Seven .esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 218 of 853 Record Number 43094 Mens Lobby Restroom 130 There is less than the required clear floor space provided in front of the urinal in the restroom to allow an accessible forward approach. Finding 29.50 inches Code At least 30.00 inches ADA 4.18.3, CA 11B-605.3, CA 11B-305.3 rovide the required minimum clear floor space in front of the rinal designated to be accessible in the restroom, for a forward Dproach. riority Six esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,707 $0.00 Record Number 43095 Mens Lobby Restroom 130 The urinal center line is not compliant. Finding 12.87 inches Code At least 15.00 inches ADA 4.18.2, CA 11B-605.3 Provide a compliant urinal with recommended values. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,300 $0.00 Record Number 43096 Mens Lobby Restroom 130 The shields extend greater than 24" in front of the urinal. The width between the shields is less than required. Finding 27.12 inches Code At least 36.00 inches ADA 4.18.2, CA 11B-605.3, CA 11B-305.7 odify or replace the urinal shields in the restroom to provide le required clearance between the shields for the urinal esignated as accessible. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 219 of 853 Record Number 43097 Mens Lobby Restroom 130 Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43098 Mens Lobby Restroom 130 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43092 Mens Lobby Restroom 130 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.61 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set erogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 220 of 853 Record Number 43093 Mens Lobby Restroom 130 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43091 Mens Lobby Restroom 130 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $277 $0.00 Record Number 43127 Womens Lobby Restroom 131 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.87 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 Raise or replace the lavatory to provide the minimum required Dron height. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 221 of 853 Record Number 43128 Womens Lobby Restroom 131 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.25 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven esolution Not Set _-rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43129 Womens Lobby Restroom 131 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. riority Two esolution Not Set rogress Not_Started ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43130 Womens Lobby Restroom 131 Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Post gender use signage on the center of the door at the -quired height. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 222 of 853 Record Number 43131 Womens Lobby Restroom 131 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43124 Womens Lobby Restroom 131 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43125 Womens Lobby Restroom 131 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 223 of 853 Record Number 43126 Womens Lobby Restroom 131 Feminine Products The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43138 Womens Staff Restroom 179 There is insufficient clear floor space in the compartment. Finding 59.75 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 Modify or replace the compartment to provide adequate clear _. Dor space. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43142 Womens Staff Restroom 179 The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 224 of 853 Record Number 43143 Womens Staff Restroom 179 Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. priority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Record Number 43144 Womens Staff Restroom 179 The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43139 Womens Staff Restroom 179 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 225 of 853 Record Number 43141 Womens Staff Restroom 179 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43145 Womens Staff Restroom 179 The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 17.00 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43148 EOC/Police Unisex Staff Restroom 152 The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 226 of 853 Record Number 43147 EOC/Police Unisex Staff Restroom 152 The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. °riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $804 $0.00 Record Number 43149 EOC/Police Unisex Staff Restroom 152 The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $280 $0.00 Record Number 43150 EOC/Police Unisex Staff Restroom 152 The entrance door swings into the turning space within the restroom. Finding 28.75 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $8,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 227 of 853 Record Number 43155 EOC/Police Unisex Staff Restroom 152 The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Record Number 43157 EOC/Police Unisex Staff Restroom 152 The signage is not mounted at the required height. Finding 59.50 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Dst compliant signage at the restroom. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43158 EOC/Police Unisex Staff Restroom 152 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Seven esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 228 of 853 Record Number 43152 EOC/Police Unisex Staff Restroom 152 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 26.50 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required iron height. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43153 EOC/Police Unisex Staff Restroom 152 Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 22.25 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,286 $0.00 Record Number 43154 EOC/Police Unisex Staff Restroom 152 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Seven .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 229 of 853 Record Number 43156 EOC/Police Unisex Staff Restroom 152 All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43151 EOC/Police Unisex Staff Restroom 152 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43160 Mens Restroom 110 The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 Provide a compliant door lock for the door that does not require ght grasping, pinching, or twisting of the wrist to operate. riority Four esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 230 of 853 Record Number 43166 Mens Restroom 110 The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.62 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. Priority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Record Number 43167 Mens Restroom 110 The top of the mirror is not at the compliant height. Finding 73.12 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43163 Mens Restroom 110 Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 22.50 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. Priority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 231 of 853 Record Number 43164 Mens Restroom 110 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set .-rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43165 Mens Restroom 110 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. riority Two .esolution Not Set rogress Not_Started ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43162 Mens Restroom 110 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 26.75 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 Raise or replace the lavatory to provide the minimum required oron height. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 232 of 853 Record Number 43168 Mens Restroom 110 Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43169 Mens Restroom 110 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43161 Mens Restroom 110 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 233 of 853 Record Number 43171 EOC/Police Unisex Staff Restroom 152 The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 46.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43170 EOC/Police Unisex Staff Restroom 152 The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43173 EOC/Police Unisex Staff Restroom 152 The height of the toilet seat is not at the required height. Finding 19.50 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,707 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 234 of 853 Record Number 43172 EOC/Police Unisex Staff Restroom 152 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43175 EOC/Police Unisex Staff Restroom 152 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 32.87 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43184 Mens Restroom In Area 4 Sessions Room The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 36.62 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 235 of 853 Record Number 43182 Mens Restroom In Area 4 Sessions Room The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.25 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43185 Mens Restroom In Area 4 Sessions Room The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 13.00 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43207 Womens Restroom In Area 4 Sessions Room The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 236 of 853 Record Number 43208 Womens Restroom In Area 4 Sessions Room The entrance door swings into the turning space within the restroom. Finding 29.12 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $8,200 $0.00 Record Number 43209 Womens Restroom In Area 4 Sessions Room The top of the mirror is not at the compliant height. Finding 73.25 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43218 Womens Restroom In Area 4 Sessions Room The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 19.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser at a compliant height and location. riority Three .esolution Not Set 'rogress Not_Started .-ssignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 237 of 853 Record Number 43217 Womens Restroom In Area 4 Sessions Room The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 38.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43261 Mens Restroom 110 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.37 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43263 Mens Restroom 110 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 34.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 238 of 853 Record Number 43280 Womens Restroom 111 The grab bar on the rear wall is not at the correct height. Finding 32.75 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Record Number 43277 Womens Restroom 111 The height of the toilet seat is not at the required height. Finding 20.00 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. riority Six esolution Not Set 'regress Not_Started .ssignment Not Set 06/30/2013 $1,707 $0.00 Record Number 43276 Womens Restroom 111 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 239 of 853 Record Number 43279 Womens Restroom 111 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 30.37 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43281 Womens Restroom 111 The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 16.75 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43301 Mens Restroom In Area 4 Sessions Room The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 240 of 853 Record Number 43302 Mens Restroom In Area 4 Sessions Room The entrance door swings into the turning space within the restroom. Finding 30.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $8,200 $0.00 Record Number 43305 Mens Restroom In Area 4 Sessions Room The top of the mirror is not at the compliant height. Finding 73.25 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43303 Mens Restroom In Area 4 Sessions Room Lavatory The height of the counter surface is greater than allowed. Finding 34.12 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 Relocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 241 of 853 Record Number 43304 Mens Restroom In Area 4 Sessions Room Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.75 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set _ rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43306 Womens Restroom 111 The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 "odify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in a wheelchair. riority Six .esolution Not Set rogress Not_Started ..ssignment Not Set 06/30/2013 $1,800 $0.00 Record Number 43307 Womens Restroom 111 The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 Provide a compliant door lock for the door that does not require ght grasping, pinching, or twisting of the wrist to operate. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 242 of 853 Record Number 43308 Womens Restroom 111 The entrance door swings into the turning space within the restroom. Finding 47.50 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $8,200 $0.00 Record Number 43313 Womens Restroom 111 The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.62 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 I ower the mirror so the bottom edge of the reflective surface is i to higher than recommended above the finished floor. riority Seven .esolution Not Set 'rogress Not_Started _,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43314 Womens Restroom 111 The top of the mirror is not at the compliant height. Finding 73.25 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 243 of 853 Record Number 43310 Womens Restroom 111 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 26.62 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required iron height. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43311 Womens Restroom 111 Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 22.50 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,286 $0.00 Record Number 43312 Womens Restroom 111 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 244 of 853 Record Number 43315 Womens Restroom 111 Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43316 Womens Restroom 111 There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43309 Womens Restroom 111 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 245 of 853 Record Number 43322 City Managers Unisex Restroom Feminine products disposal distance from front of the toilet is not compliant. Finding 17.00 inches Code Up to 12.00 inches rovide feminine products disposal at the required distance om front of the toilet. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43323 City Managers Unisex Restroom The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 12.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43320 City Managers Unisex Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.37 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 246 of 853 Record Number 43338 Mens Restroom In The West Lobby There is less than the required latch side clearance on the pull side of the door. Finding 7.50 inches Code At least 18.00 inches ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404 rovide required latch side clearance on the pull side of the °riority Five esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,200 $0.00 Record Number 43335 Mens Restroom In The West Lobby The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43336 Mens Restroom In The West Lobby Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 247 of 853 Record Number 43337 Mens Restroom In The West Lobby The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43333 Mens Restroom In The West Lobby The height of the side grab bar is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43334 Mens Restroom In The West Lobby The grab bar on the rear wall is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 248 of 853 Record Number 43339 Mens Restroom In The West Lobby The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 13.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43331 Mens Restroom In The West Lobby The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.87 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43340 Womens Restroom In The West Lobby The top of the mirror is not at the compliant height. Finding 73.37 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. priority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 249 of 853 Record Number 43347 Mens Restroom In The West Lobby Lavatory The height of the counter surface is greater than allowed. Finding 34.25 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,286 $0.00 Record Number 43348 Mens Restroom In The West Lobby Male The gender use signage on the entrance door is not mounted at the required height. Finding 61.12 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43350 City Managers Unisex Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 )stall a compliant privacy lock with occupancy indicator to the Dor. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $804 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 250 of 853 Record Number 43353 City Managers Unisex Restroom All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 3st gender use signage on the center of the door at the ?quired height. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43354 City Managers Unisex Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Seven .esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $158 $0.00 Record Number 43352 City Managers Unisex Restroom Lavatory The height of the counter surface is greater than allowed. Finding 34.50 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 251 of 853 Record Number 43370 Womens Restroom In The West Lobby There is insufficient clear floor space in the compartment. Finding 59.75 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 odify or replace the compartment to provide adequate clear Dor space. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43377 Womens Restroom In The West Lobby Feminine products disposal distance from front of the toilet is not compliant. Finding 16.87 inches Code Up to 12.00 inches rovide feminine products disposal at the required distance om front of the toilet. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43373 Womens Restroom In The West Lobby The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 252 of 853 Record Number 43374 Womens Restroom In The West Lobby Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. priority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Record Number 43375 Womens Restroom In The West Lobby The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43376 Womens Restroom In The West Lobby There is less than the required latch side clearance on the pull side of the door. Finding 8.25 inches Code At least 18.00 inches ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404 rovide required latch side clearance on the pull side of the Dor. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 253 of 853 Record Number 43372 Womens Restroom In The West Lobby The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43378 Womens Restroom In The West Lobby The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 12.87 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43002 Drinking Fountain Near Womens Staff Restroom 179 The height of the water stream is less than required. Finding 1.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 djust the flow of the water stream to a compliant height. riority Six .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 254 of 853 Record Number 43003 Drinking Fountain Near Womens Staff Restroom 179 There is not enough clear floor space for a parallel approach in an alcove. Finding 50.50 inches Code At least 60.00 inches ADA 4.2.4.2, CA 11B-602.2, CA 11B-305.7.2 rovide the required clear floor space or reduce the depth of le alcove. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $108 $0.00 Record Number 43001 Drinking Fountain Near Womens Staff Restroom 179 The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $2,500 $0.00 Assembly Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43260 Council Chambers 101 There are not enough accessible seats at the location with respect to the total number of seats available. Finding None Found Code At least 4.00 seats CA 11B-221.2, CA 11B-802.1 "rovide a compliant amount of accessible seats. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $600 $0.00 Locker Rooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 255 of 853 Record Number 43048 Mens Locker Room 176 No International Symbol of Accessibility is found at the accessible locker. Finding None Found ADA 4.35 esignate the accessible locker with the International Symbol of ccessibility. °riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $58 $0.00 Record Number 43049 Mens Locker Room 176 The height of the bench is not compliant. Finding 19.50 inches Code 17.00 - 19.00 inches ADA 4.35.4, ADA 4.37, CA 11B-803.4, CA 11B-903.5, CA 11B-222 (stall a compliant bench in the locker room. Provide sufficient ear floor space alongside the the bench to allow a person sing a wheelchair to transfer on to the bench. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43229 Womens Locker Room 178 There are no accessible benches in the locker room. Finding None Found ADA 4.35.4, ADA 4.37 (stall compliant benches in the locker room. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 256 of 853 Record Number 43228 Womens Locker Room 178 esignate the accessible locker with the International Symbol of ccessibility. 06/30/2013 $58 $0.00 No International Symbol of Accessibility is found at the accessible locker. Finding None Found ADA 4.35 °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43206 Womens Restroom In Area 4 Sessions Room There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 Tnstall visual warning devices integrated with the facility's alarm istem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Six esolution Not Set rogress Not_Started ..ssignment Not Set 06/30/2013 $2,200 $0.00 Record Number 43300 Mens Restroom In Area 4 Sessions Room There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 Tnstall visual warning devices integrated with the facility's alarm istem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Six esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $2,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 257 of 853 Record Number 43351 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. 06/30/2013 $2,200 $0.00 City Managers Unisex Restroom There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43389 EOC Staff Lounge The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Tnsulate or otherwise configure the water supply and drain Ipes under the sink to protect against contact. Make certain sere are no sharp or abrasive surfaces under the sink. riority Two esolution Not Set rogress Not_Started ..ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43390 EOC Staff Lounge Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 "elocate the dispenser to the correct height. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $110 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 258 of 853 Record Number 43391 EOC Staff Lounge Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 48.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $110 $0.00 Record Number 43387 EOC Staff Lounge The table knee depth does not meet required standards. Finding 12.00 inches Code At least 19.00 inches ADA 4.27, CA 11B-306, CA 11B-902 Provide compliant tables. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,174 $0.00 Record Number 43388 EOC Staff Lounge There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 259 of 853 Record Number 42949 South Conference Room 138, East Conference Room 167, & North Conference Room 190 There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43072 New Addition Area 1 Conference Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Three esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $158 $0.00 Record Number 43133 Break Room 198 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 51.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Three esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $110 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 260 of 853 Record Number 43192 Caucus Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 52.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $110 $0.00 Record Number 43191 Caucus Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 Install an International Symbol of Accessibility at the table. riority Three .esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $158 $0.00 Record Number 43197 Staff Lounge 180 No visual alarms found at the location. Finding None Found ADA 4.27 -ovide visual alarms at the location. °riority Six .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $388 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 261 of 853 Record Number 43202 Staff Lounge 180 The side reach height of the controls on the vending machine is greater than the allowed maximum height. Finding 58.00 inches Code Up to 54.00 inches ADA 4.2.5, CA 11B-309, CA 11B-228 rovide a compliant vending machine. riority Seven esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $0.00 Record Number 43203 Staff Lounge 180 The side reach height of the controls on the vending machine is greater than the allowed maximum height. Finding 55.00 inches Code Up to 54.00 inches ADA 4.2.5, CA 11B-309, CA 11B-228 rovide a compliant vending machine. riority Seven esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $0.00 Record Number 43200 Staff Lounge 180 Sink counter height does not meet the standards. Finding 34.25 inches Code Up to 34.00 inches CA 11B-606.3 Provide compliant sink. priority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 262 of 853 Record Number 43201 Staff Lounge 180 The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain ipes under the sink to protect against contact. Make certain iere are no sharp or abrasive surfaces under the sink. °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Record Number 43204 Staff Lounge 180 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 50.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $110 $0.00 Record Number 43205 Staff Lounge 180 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 46.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 Relocate the dispenser to the correct height. riority Seven .esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $110 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 263 of 853 Record Number 43198 Staff Lounge 180 The table knee depth does not meet required standards. Finding 7.00 inches Code At least 19.00 inches ADA 4.27, CA 11B-306, CA 11B-902 rovide compliant tables. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,174 $0.00 Record Number 43199 Staff Lounge 180 There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Seven esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $158 $0.00 Record Number 43358 West Conference Room No visual alarms found at the location. Finding None Found ADA 4.27 -ovide visual alarms at the location. °riority Six esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $388 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 264 of 853 Record Number 43360 West Conference Room The toe kick for the sink in break/conference room is not removed. Finding Not Removed CA 11B-606.2, CA 11B-305, CA 11B-306 emove the toe kick for the sink. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $612 $0.00 Record Number 43361 West Conference Room The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain ipes under the sink to protect against contact. Make certain iere are no sharp or abrasive surfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Record Number 43359 West Conference Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 265 of 853 Record Number 43366 Staff Lounge Near The Caucus Room Sink counter height does not meet the standards. Finding 36.87 inches Code Up to 34.00 inches CA 11B-606.3 rovide compliant sink. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Record Number 43367 Staff Lounge Near The Caucus Room The toe kick for the sink in break/conference room is not removed. Finding Not Removed CA 11B-606.2, CA 11B-305, CA 11B-306 emove the toe kick for the sink. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $612 $0.00 Record Number 43368 Staff Lounge Near The Caucus Room The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain 1pes under the sink to protect against contact. Make certain sere are no sharp or abrasive surfaces under the sink. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 266 of 853 Record Number 43369 Staff Lounge Near The Caucus Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 63.87 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $110 $0.00 Record Number 43364 Staff Lounge Near The Caucus Room The table knee depth does not meet required standards. Finding 11.00 inches Code At least 19.00 inches ADA 4.27, CA 11B-306, CA 11B-902 Provide compliant tables. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,174 $0.00 Record Number 43365 Staff Lounge Near The Caucus Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 267 of 853 Record Number 42957 Sink Near Plan Checker 162 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect aainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Record Number 42958 Sink Near Plan Checker 162 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 49.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 42959 Sink Near Plan Checker 162 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 268 of 853 Record Number 42978 Sink Near EOC/Police 157 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect aainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Record Number 42979 Sink Near EOC/Police 157 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 49.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 42980 Sink Near EOC/Police 157 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 46.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 269 of 853 Record Number 43052 Sink In The Mens Locker Room 176 Sink counter height is not compliant. Finding 34.25 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Seven esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Record Number 43053 Sink In The Mens Locker Room 176 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43054 Sink In The Mens Locker Room 176 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Seven esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 270 of 853 Record Number 43116 Sink Near Womens Staff Restroom 179 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 54.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43297 Sink In Womens Locker Room 178 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 49.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43298 Sink In Womens Locker Room 178 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Seven .esolution Not Set 'regress Not_Started _assignment Not Set 06/30/2013 $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 271 of 853 Record Number 43318 Sink Near Mens Restroom 110 & Womens Restroom 111 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43362 Sink Near The Mayors Reception Counter The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 Make sure there is no toe kick at the sink. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $420 $0.00 Record Number 43363 Sink Near The Mayors Reception Counter The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 272 of 853 Record Number 43317 Picnic Table At The Staff Lounge 180 Patio The required percentage of picnic tables provided are not accessible. Finding None Found Code At least 1.00 tables ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 rovide a sufficient number of compliant picnic tables. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $500 $0.00 Accessible Showers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43105 Accessible Shower In The Mens Locker Room 176 The opening width of the shower compartment is less than required. Finding 35.62 inches Code At least 42.00 inches ADA 4.21.2, CA 11B-608.2 Increase the shower compartment opening to the correct width. riority Seven esolution Not Set rogress Not_Started .,ssignment Not Set 06/30/2013 $1,840 $0.00 Record Number 43107 Accessible Shower In The Mens Locker Room 176 The slope of the surface for the shower is not compliant. Finding 3.10 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-608.9 "epair the floor of the shower to provide a compliant slope. riority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 273 of 853 Record Number 43106 Accessible Shower In The Mens Locker Room 176 The shower compartment width is not compliant. Finding 56.00 inches Code At least 60.00 inches ADA 4.21.7 odify or replace the shower to provide a compliant accessible lower compartment. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $3,500 $0.00 Record Number 43110 Accessible Shower In The Mens Locker Room 176 Shower seat length is not compliant. Finding Not Accessible ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant seat that extends the full length of the lower. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,068 $0.00 Record Number 43111 Accessible Shower In The Mens Locker Room 176 The distance between the folding seat and the adjacent wall is not compliant. Finding 2.37 inches Code Up to 1.50 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 Provide a compliant shower seat. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 274 of 853 Record Number 43112 Accessible Shower In The Mens Locker Room 176 The folding seat in the accessible shower is not mounted at a compliant height above the finished floor. Finding 18.25 inches Code 18.00 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 emount the folding seat to a compliant height above the nished floor. °riority Seven esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43113 Accessible Shower In The Mens Locker Room 176 The soap dish is not mounted at a compliant height. Finding 40.50 inches Code 15.00 - 40.00 inches CA 11B-608.10 elocated the soap dish on the same wall as the water controls a compliant height. riority Seven esolution Not Set 'regress Not_Started .ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43109 Accessible Shower In The Mens Locker Room 176 The grab bar is mounted on walls over the seat. Finding Over Seat ADA 4.21.4, CA 11B-609, CA 11B-608.3 ove the grab bar so that it is mounted on walls opposite and ijacent to the front edge of the seat, but not extended to 'elude that portion of wall over the seat. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 275 of 853 Record Number 43108 Accessible Shower In The Mens Locker Room 176 The hand-held sprayer unit is not mounted at the required height above the finished floor. Finding 55.00 inches Code Up to 48.00 inches ADA 4.21, ADA 4.21.6, CA 11B-608.5 rovide a compliant hand-held sprayer unit with a hose. riority Seven esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $385 $0.00 Record Number 43114 Accessible Shower In The Mens Locker Room 176 The water valve distance from seat wall is not compliant. Finding 34.50 inches Code 18.00 - 24.00 inches ADA 4.21.5, CA 11B-608.5 rovide a compliant water valve. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43115 Accessible Shower In The Mens Locker Room 176 The water control valve is not mounted at a compliant height. Finding 49.50 inches Code Up to 40.00 inches ADA 4.21.5, CA 11B-608.5 emount the water control valve. priority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $554 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 276 of 853 Record Number 43282 Accessible Shower In Womens Locker Room 178 The opening width of the shower compartment is less than required. Finding 34.50 inches Code At least 42.00 inches ADA 4.21.2, CA 11B-608.2 (crease the shower compartment opening to the correct idth. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,840 $0.00 Record Number 43284 Accessible Shower In Womens Locker Room 178 The slope of the surface for the shower is not compliant. Finding 4.00 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-608.9 epair the floor of the shower to provide a compliant slope. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,840 $0.00 Record Number 43283 Accessible Shower In Womens Locker Room 178 The shower compartment width is not compliant. Finding 57.62 inches Code At least 60.00 inches ADA 4.21.7 odify or replace the shower to provide a compliant accessible lower compartment. riority Seven .esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 277 of 853 Record Number 43286 Accessible Shower In Womens Locker Room 178 The grab bar is mounted on walls over the seat. Finding Over Seat ADA 4.21.4, CA 11B-609, CA 11B-608.3 ove the grab bar so that it is mounted on walls opposite and ijacent to the front edge of the seat, but not extended to 'elude that portion of wall over the seat. °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,840 $0.00 Record Number 43290 Accessible Shower In Womens Locker Room 178 The soap dish is not mounted at a compliant height. Finding 41.00 inches Code 15.00 - 40.00 inches CA 11B-608.10 elocated the soap dish on the same wall as the water controls a compliant height. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43287 Accessible Shower In Womens Locker Room 178 Shower seat length is not compliant. Finding Not Accessible ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant seat that extends the full length of the lower. riority Seven .esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $1,068 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 278 of 853 Record Number 43288 Accessible Shower In Womens Locker Room 178 The distance between the folding seat and the adjacent wall is not compliant. Finding 2.25 inches Code Up to 1.50 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant shower seat. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43289 Accessible Shower In Womens Locker Room 178 The folding seat in the accessible shower is not mounted at a compliant height above the finished floor. Finding 19.00 inches Code 18.00 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 emount the folding seat to a compliant height above the nished floor. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43285 Accessible Shower In Womens Locker Room 178 The hand-held sprayer unit is not mounted at the required height above the finished floor. Finding 55.25 inches Code Up to 48.00 inches ADA 4.21, ADA 4.21.6, CA 11B-608.5 rovide a compliant hand-held sprayer unit with a hose. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $385 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 279 of 853 Record Number 43291 Accessible Shower In Womens Locker Room 178 The water valve distance from seat wall is not compliant. Finding 35.00 inches Code 18.00 - 24.00 inches ADA 4.21.5, CA 11B-608.5 rovide a compliant water valve. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43292 Accessible Shower In Womens Locker Room 178 The water control valve is not mounted at a compliant height. Finding 50.00 inches Code Up to 40.00 inches ADA 4.21.5, CA 11B-608.5 emount the water control valve. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $554 $0.00 Record Number 43327 Accessible Shower In The City Managers Office Either there is no grab bar on the control wall or the length of the grab bar is not compliant. Finding 32.00 inches on center Code 36.00 inches on center ADA 4.21.4 rovide a compliant grab bar on the control wall. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 280 of 853 Record Number 43328 Accessible Shower In The City Managers Office Length of grab bar on opposite wall is not compliant. Finding 21.00 inches Code At least 24.00 inches ADA 4.21.4 rovide a compliant grab bar. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43326 Accessible Shower In The City Managers Office The center line of the hand-held sprayer unit is not a compliant distance from the rear of the seat edge. Finding 28.50 inches Code Up to 27.00 inches ADA 4.21, ADA 4.21.6, CA 11B-608.5 rovide a compliant hand-held sprayer unit with a hose. riority Seven esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $385 $0.00 Record Number 43329 Accessible Shower In The City Managers Office The water control valve is not mounted at a compliant height. Finding 47.50 inches Code Up to 40.00 inches ADA 4.21.5, CA 11B-608.5 demount the water control valve. priority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $554 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 281 of 853 Record Number 43410 EOC First Aid Kit Eye Washing Station - Eye Washing Station The highest point of operation for the element is not compliant. Finding 62.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Record Number 43411 EOC First Aid Kit Emergency Lighting Station - Other The highest point of operation for the element is not compliant. Finding 63.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Record Number 43412 EOC First Aid Kit First Aid Kit - Thermostat The highest point of operation for the element is not compliant. Finding 72.25 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 282 of 853 Record Number 43418 EOC Staff Lounge Telephone Telephone - Other The highest point of operation for the element is not compliant. Finding 60.75 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Record Number 43421 EOC Computer Station Computer Station - Computer Station The knee height is not compliant. Finding 26.12 inches Code At least 27.00 inches ADA 4.2 Hdjust knee height to the recommended value. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43267 First Aid Kit In Staff Lounge 180 First Aid Kit - Other The highest point of operation for the element is not compliant. Finding 68.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. 'riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set $50 $0.00 Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 283 of 853 Record Number 42975 Benches The bench height is not compliant. Finding 15.25 inches Code 17.00 - 19.00 inches ADA 5.8, ADA A4.2.6 djust the bench height to recommended value. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Record Number 42976 Benches The bench back rest height is not compliant. Finding 16.87 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench back rest height to recommended value. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Record Number 42992 Benches Near The Planning & Engineering Counters The bench back rest height is not compliant. Finding 17.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench back rest height to recommended value. °riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 284 of 853 Record Number 43044 Benches Near The Finance Counters The bench back rest height is not compliant. Finding 17.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 djust the bench back rest height to recommended value. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Record Number 43061 Benches Near The Building & Safety Counters The bench back rest height is not compliant. Finding 17.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 djust the bench back rest height to recommended value. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 285 of 853 Fire Station #70 Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29193 Parking Off Madison Street There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $250 $0.00 Record Number 29194 Parking Off Madison Street Accessible Space The slope of the accessible parking space is not compliant. Finding 2.60 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. riority Seven .esolution Not Set 'rogress Not_Started .assignment Not Set $3,800 $0.00 Record Number 29196 Parking Off Madison Street Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. riority Three esolution Not Set rogress Not_Started Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 286 of 853 Record Number 29195 Parking Off Madison Street Accessible Space Parking space signage contains the word handicap. Finding None Found ADA 4.6.4, CA 11B-502 rovide compliant signage. Remove the word handicap. riority Three .esolution Not Set rogress Not_Started assignment Not Set $300 $0.00 Record Number 29201 Parking Off Madison Street Accessible Space The bottom edge of the post -mounted signage designating the accessible parking space is not at the required height. Finding 73.00 inches Code At least 80.00 inches ADA 4.6.4, CA 11B-502.6 Dst signage at a compliant height. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $158 $0.00 Record Number 29202 Parking Off Madison Street Accessible Space The access aisle does not meet the minimum required width. Finding 92.00 inches Code At least 96.00 inches ADA 4.1.2(5) Re -stripe the access aisle. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 287 of 853 Record Number 29203 Parking Off Madison Street Accessible Space The slope of the access aisle is not compliant. Finding 2.40 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the access aisle to provide a compliant surface slope. riority Seven .esolution Not Set 'rogress Not_Started assignment Not Set $3,800 $0.00 Record Number 29206 Parking Off Madison Street Accessible Space The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. Finding None Found CA 11B-502.3.3 aint the words "NO PARKING' a compliant height within the :cess aisle. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $250 $0.00 Record Number 29204 Parking Off Madison Street Accessible Space The access aisle markings are faded, damaged, or otherwise not viewable. Finding None Found CA 11B-502.3 e-stripe the access aisle so as to discourage parking. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 288 of 853 Record Number 29205 Parking Off Madison Street Accessible Space The hatched lines are striped a noncompliant distance on center. Finding Not on 36" center CA 11B-502.3.3 e-stripe the hatched lines in a contrasting color at a compliant stance on center. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $350 $0.00 Record Number 29198 Parking Off Madison Street Accessible Space The International Symbol of Accessibility (ISA) surface identification is not centered and aligned with the end of the space. Finding Not Visible ADA 4.6.4, CA 11B-502.6.4 rovide a compliant International Symbol of Accessibility (ISA) entered and aligned with the end of the accessible parking Jace. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $220 $0.00 Record Number 29199 Parking Off Madison Street Accessible Space The surface identification does not contrast from the parking space surface. Finding See Above Code Not White on Blue ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. Priority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 289 of 853 Record Number 29200 rovide compliant surface identification at the accessible parking Jace. $220 $0.00 Parking Off Madison Street Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 27.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 riority Three .esolution Not Set rogress Not_Started Assignment Not Set Record Number 29197 Parking Off Madison Street Accessible Space ISA surface identification is faded and not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.6.4 'Repaint the ISA surface identification in the parking space. riority Three .esolution Not Set rogress Not_Started Assignment Not Set $117 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29149 Path Of Travel From The Accessible Space Path Of Travel From The Accessible Space There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 rovide detectable warnings. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $19G $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 290 of 853 Record Number 29306 ,ovide detectable warnings. $190 $0.00 Path Of Travel From The Public Right Of Way Off Madison Street Path Of Travel From The Public Right Of Way Off Madison Street There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 riority Three .esolution Not Set rogress Not_Started Assignment Not Set Record Number 29307 Path Of Travel From The Public Right Of Way Off Madison Street Path Of Travel From The Public Right Of Way Off Madison Street The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 Provide a compliant crosswalk. riority Three .esolution Not Set rogress Not_Started .ssignment Not Set $1,100 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29061 Captains Barrack Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 291 of 853 Record Number 29066 Door Between Bay And Hallway Next To Captains Barrack The height of the threshold at the entrance door is greater than allowed. Finding 4.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 29064 Door Between Bay And Hallway Next To Captains Barrack Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 29065 Door Between Bay And Hallway Next To Captains Barrack Push / Pull Door hardware is not mounted at the correct height. Finding 50.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 Mount the door hardware at the recommended height. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 292 of 853 Record Number 29087 Unisex Restroom Next To Kitchen Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 29137 Unisex Restroom Next To Captains Office Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 20.50 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance for the door. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,921 $0.00 Record Number 29136 Unisex Restroom Next To Captains Office Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 293 of 853 Record Number 29269 Captains Office Lever The door opening force for this door is greater than allowed. Finding 13.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 29354 Main Entrance Next To Reception Pull Side There is no level landing at this door. Finding 4.70 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $1,500 $0.00 Record Number 29353 Main Entrance Next To Reception Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 294 of 853 Record Number 29164 Main Entrance Next To Reception There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 29266 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29454 Unisex Restroom Next To Kitchen The approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction does not meet the minimum required clearance. Finding 47.87 inches Code At least 48.00 inches ADA 4.17.3, CA 11B-604.8.1.2, CA 11B-404.2 "rovide clearance between the door side of the compartment -id any obstruction that meets the minimum required earance. Priority Five esolution Not Set rogress Not_Started ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 295 of 853 Record Number 29467 Unisex Restroom Next To Kitchen The coat hook is not mounted at the correct height. Finding 68.25 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Two esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Record Number 29465 Unisex Restroom Next To Kitchen The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 29466 Unisex Restroom Next To Kitchen The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Adjust the inside handle so that it is located near the latch. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $129 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 296 of 853 Record Number 29463 Unisex Restroom Next To Kitchen The height of the side grab bar is not at the correct height. Finding 34.00 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set $500 $0.00 Record Number 29464 Unisex Restroom Next To Kitchen The grab bar on the rear wall is not at the correct height. Finding 34.00 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $231 $0.00 Record Number 29460 Unisex Restroom Next To Kitchen The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 0.12 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 297 of 853 Record Number 29461 Unisex Restroom Next To Kitchen The distance from the back wall to the front of the grab bar is less than required. Finding 53.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 29462 Unisex Restroom Next To Kitchen The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 21.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Five esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 29455 Unisex Restroom Next To Kitchen The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 20.00 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. riority Five esolution Not Set 'rogress Not_Started .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 298 of 853 Record Number 29457 Unisex Restroom Next To Kitchen The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Four .esolution Not Set rogress Not_Started Assignment Not Set $127 $0.00 Record Number 29458 Unisex Restroom Next To Kitchen The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Five .esolution Not Set 'rogress Not_Started _,ssignment Not Set $2,500 $0.00 Record Number 29459 Unisex Restroom Next To Kitchen There is less than the required minimum space in front of the toilet. Finding 43.75 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 'Treate the required minimum clear space in front of the toilet. Priority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 299 of 853 Record Number 29498 Unisex Restroom Next To Captains Office The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 50.75 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. °riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $1,707 $0.00 Record Number 29506 Unisex Restroom Next To Captains Office Feminine products disposal distance from front of the toilet is not compliant. Finding 55.00 inches Code Up to 12.00 inches rovide feminine products disposal at the required distance om front of the toilet. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Record Number 29505 Unisex Restroom Next To Captains Office The coat hook is not mounted at the correct height. Finding 53.00 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 300 of 853 Record Number 29504 Unisex Restroom Next To Captains Office The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 0.12 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. priority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $250 $0.00 Record Number 29502 Unisex Restroom Next To Captains Office The distance from the back wall to the front of the grab bar is less than required. Finding 53.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 29503 Unisex Restroom Next To Captains Office The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 23.50 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 301 of 853 Record Number 29499 Unisex Restroom Next To Captains Office The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.00 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 29501 Unisex Restroom Next To Captains Office The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 33.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 29276 Unisex Restroom Next To Kitchen The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $804 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 302 of 853 Record Number 29278 Unisex Restroom Next To Kitchen The height of the urinal rim in the restroom is not compliant. Finding 17.50 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 )wer the urinal designated to be accessible in the restroom so iat the rim height is compliant. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set $1,397 $0.00 Record Number 29279 Unisex Restroom Next To Kitchen The height of the urinal flush control in the restroom is greater than the required maximum height. Finding 43.25 inches Code At least 44.00 inches ADA 4.18.4, CA 11B-605.4 )wer the flush control valve on the urinal to a height not reater than the required maximum height. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $227 $0.00 Record Number 29280 Unisex Restroom Next To Kitchen The urinal does not meet the requirement for the minimum projection from the back wall to the front of the urinal rim. Finding 13.00 inches Code At least 14.00 inches ADA 4.18.2, CA 11B-605.2 (stall a urinal that meets the minimum projection ?quirements. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $951 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 303 of 853 Record Number 29283 Unisex Restroom Next To Kitchen The width between urinal shields in the restroom is less than required. Finding 28.50 inches Code At least 30.00 inches ADA 4.18.3 odify or replace the urinal shields in the restroom to provide le required shield -width clearance. Priority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $230 $0.00 Record Number 29281 Unisex Restroom Next To Kitchen There is less than the required clear floor space provided in front of the urinal in the restroom to allow an accessible forward approach. Finding 28.50 inches Code At least 30.00 inches ADA 4.18.3, CA 11B-605.3, CA 11B-305.3 rovide the required minimum clear floor space in front of the rinal designated to be accessible in the restroom, for a forward Dproach. riority Five .esolution Not Set 'rogress Not_Started _,ssignment Not Set $1,707 $0.00 Record Number 29282 Unisex Restroom Next To Kitchen The urinal center line is not compliant. Finding 14.12 inches Code At least 15.00 inches ADA 4.18.2, CA 11B-605.3 Provide a compliant urinal with recommended values. Priority Five .esolution Not Set rogress Not_Started Assignment Not Set $2,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 304 of 853 Record Number 29277 Unisex Restroom Next To Kitchen Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'regress Not_Started ,ssignment Not Set $149 $0.00 Record Number 29284 Unisex Restroom Next To Kitchen All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. riority Three .esolution Not Set 'regress Not_Started .ssignment Not Set $158 $0.00 Record Number 29285 Unisex Restroom Next To Kitchen There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 305 of 853 Record Number 29509 Unisex Restroom Next To Captains Office There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 32.50 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $14,000 $0.00 Record Number 29511 Unisex Restroom Next To Captains Office Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 29513 Unisex Restroom Next To Captains Office There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 306 of 853 Record Number 29512 Unisex Restroom Next To Captains Office All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $158 $0.00 Record Number 29510 Unisex Restroom Next To Captains Office Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29351 Drinking Fountain In Reception Area There is less than the required minimum knee clearance height Finding 23.00 inches Code At least 27.00 inches ADA 4.15.5, CA 11B-602.2, CA 11B-306 "rovide a fountain with the required knee and toe clearances. riority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 307 of 853 Record Number 29352 Drinking Fountain In Reception Area The drinking fountain is not set entirely in an alcove. Finding None Found CA 11B-602.9 rovide compliant wing walls or barrier at the drinking fountain. riority Five esolution Not Set rogress Not_Started Assignment Not Set $640 $0.00 Record Number 29350 Drinking Fountain In Reception Area The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. riority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set $2,500 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29343 Visual Alarms There are no visual warning devices at the facility. Finding None Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 Tnstall visual warning devices integrated with the facility's alarm istem in all common areas. Priority Six esolution Not Set rogress Not_Started Assignment Not Set $2,200 $0.00 Accessible Showers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 308 of 853 Record Number 29311 Unisex Restroom Next To Captains Office There are not enough accessible showers with respect to the total number of showers available. Finding None Found Code At least 1.00 showers ADA 4.21.2, CA 11B-213.3.6 rovide the required amount of compliant accessible showers. riority Six .esolution Not Set rogress Not_Started _,ssignment Not Set $4,500 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29059 Main Entrance Next To Reception Door Bell - Other The highest point of operation for the element is not compliant. Finding 51.50 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 Make sure that the highest point of operation is within the recommended value. riority Three esolution Not Set 'rogress Not_Started assignment Not Set $50 $0.00 Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29189 Benches There are not enough accessible benches at the location with respect to the number of benches available. Finding None Found Code At least 1.00 benches ADA 5.8, ADA A4.2.6 rovide compliant accessible benches at the location. riority Four .esolution Not Set rogress Not_Started .,ssignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 309 of 853 Record Number 29190 Benches The bench height is not compliant. Finding 15.75 inches Code 17.00 - 19.00 inches ADA 5.8, ADA A4.2.6 djust the bench height to recommended value. riority Four esolution Not Set rogress Not_Started Assignment Not Set $800 $0.00 Record Number 29191 Benches The bench back rest height is not compliant. Finding 17.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 Hdjust the bench back rest height to recommended value. riority Four esolution Not Set rogress Not_Started Assignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 310 of 853 Fire Station #93 Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46485 Parking Parking Lot Warning Sign The point of contact and telephone number for reclaiming towed vehicles have been left blank. Finding Sign not Filled CA 11B-502.8.2 II in the blank spaces with the point of contact and telephone umber for reclaiming towed vehicles. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $250 $0.00 Record Number 46481 Parking Accessible Space Next To Main Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the lternational Symbol of Accessibility. riority Not Set esolution Not Set rogress Not Set .-ssignment Not Set $300 $0.00 Record Number 46482 Parking Accessible Space Next To Main Entrance The access aisle does not meet the minimum required width. Finding 92.00 inches Code At least 96.00 inches ADA 4.1.2(5) Re -stripe the access aisle. riority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 311 of 853 Record Number 46483 Parking Accessible Space Next To BBQ Area There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $300 $0.00 Record Number 46484 Parking Accessible Space Next To BBQ Area The access aisle does not meet the minimum required width. Finding 92.50 inches Code At least 96.00 inches ADA 4.1.2(5) e-stripe the access aisle. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46487 Path Of Travel From The Public Right Of Way Off Adams Street Change In Level Next To Main Entrance There is a change in elevation greater than recommended value. Finding 0.75 inches Code Up to 0.25 inches ADA 4.3.8, CA 11B-303, CA 11B-403.4 rnsure that the change in elevation is within the recommended Slue. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $150 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 312 of 853 Record Number 46488 (stall side extensions, modify, relocate, or lower the item so 'at it is not a protruding object into the circulation route. $640 $0.00 Path Of Travel In Kitchen Counter The leading edge of the item protrudes into the circulation route greater than permitted. Finding 6.50 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46454 Office Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 53.25 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 46453 Office Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 'adjust the closer on the door to meet the door opening force requirements. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 313 of 853 Record Number 46459 Unisex Restroom Next To Office Push Side There is less than the required latch side clearance on the push side of the door. Finding 11.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 46458 Unisex Restroom Next To Office Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $25 $0.00 Record Number 46461 Door Between Reception & Hallway Break Area Push Side There is not enough clear floor space provided at the push side of the door . Finding 18.25 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide the recommended clear floor space on the push side of le door. riority Not Set .esolution Not Set 'rogress Not Set _.ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 314 of 853 Record Number 46460 Door Between Reception & Hallway Break Area Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 46462 Main Entrance Next To Reception Push Bar / Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46490 Directional Signage From The Public Right Of Way There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 Install directional signage to each accessible element or room. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 315 of 853 Record Number 46452 Copy Room/Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 46457 Main Entrance Next To Reception There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 46463 Door Between Reception & Bay There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 316 of 853 Record Number 46486 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46451 Unisex Restroom Next To Office The restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space to accommodate an individual in a wheelchair. Finding Not Accessible ADA 4.23 Consult a design professional to modify the restroom for access )mpliance. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 46464 Unisex Restroom Next To Office The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 317 of 853 Record Number 46467 Unisex Restroom Next To Office The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 rovide a compliant toilet paper dispenser. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $230 $0.00 Record Number 46465 Unisex Restroom Next To Office The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46469 Visual Alarms There are some visual warning devices, though visual warning devices are not located throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 Tnstall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, classrooms and 2neral use rooms, accessible restrooms and other accessible )oms. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,200 $0.00 Accessible Showers Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 318 of 853 Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46468 Shower In Right Unisex Restroom Next To Kitchen There are not enough accessible showers with respect to the total number of showers available. Finding None Found Code At least 1.00 showers ADA 4.21.2, CA 11B-213.3.6 Provide the required amount of compliant accessible showers. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $4,500 $0.00 Record Number 46470 Shower In Left Unisex Restroom Next To Kitchen There are not enough accessible showers with respect to the total number of showers available. Finding None Found Code At least 1.00 showers ADA 4.21.2, CA 11B-213.3.6 Provide the required amount of compliant accessible showers. 4riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $4,500 $0.00 Record Number 46471 Shower In Unisex Restroom Next To Cheifs Bedroom The opening width of the shower compartment is less than required. Finding 38.00 inches Code At least 42.00 inches ADA 4.21.2, CA 11B-608.2 Increase the shower compartment opening to the correct idth. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 319 of 853 Record Number 46477 Shower In Unisex Restroom Next To Cheifs Bedroom The soap dish is not mounted at a compliant height. Finding 57.50 inches Code 15.00 - 40.00 inches CA 11B-608.10 elocated the soap dish on the same wall as the water controls a compliant height. riority Not Set esolution Not Set 'regress Not Set .ssignment Not Set $277 $0.00 Record Number 46475 Shower In Unisex Restroom Next To Cheifs Bedroom Shower seat length is not compliant. Finding Not Accessible ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant seat that extends the full length of the lower. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,068 $0.00 Record Number 46476 Shower In Unisex Restroom Next To Cheifs Bedroom The folding seat in the accessible shower is not mounted at a compliant height above the finished floor. Finding 19.25 inches Code 18.00 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 emount the folding seat to a compliant height above the nished floor. riority Not Set esolution Not Set 'regress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 320 of 853 Record Number 46474 Shower In Unisex Restroom Next To Cheifs Bedroom The distance between the grab bar and the wall it is mounted on is not compliant. Finding 1.25 inches Code At least 1.50 inches ADA 4.21.4, CA 11B-609.3, CA 11B-608.3 emount the grab bar in the accessible shower to provide a )mpliant distance between the grab bar and the wall they are counted on. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $78 $0.00 Record Number 46478 Shower In Unisex Restroom Next To Cheifs Bedroom The operational force required to operate the water valve is not compliant Finding Not Accessible ADA 4.21.5, CA 11B-608.5, CA 11B-309.4 Provide an accessible water control device that can be operated ith one hand and a compliant pounds of force to operate. riority Not Set .esolution Not Set 'rogress Not Set _,ssignment Not Set $554 $0.00 Record Number 46479 Shower In Unisex Restroom Next To Cheifs Bedroom The water valve distance from seat wall is not compliant. Finding 27.50 inches Code 18.00 - 24.00 inches ADA 4.21.5, CA 11B-608.5 Provide a compliant water valve. 'riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 321 of 853 Record Number 46480 Shower In Unisex Restroom Next To Cheifs Bedroom The water control valve is not mounted at a compliant height. Finding 47.00 inches Code Up to 40.00 inches ADA 4.21.5, CA 11B-608.5 emount the water control valve. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $554 $0.00 Record Number 46472 Shower In Unisex Restroom Next To Cheifs Bedroom The hand-held sprayer unit is not mounted at the required height above the finished floor. Finding 65.00 inches Code Up to 48.00 inches ADA 4.21, ADA 4.21.6, CA 11B-608.5 rovide a compliant hand-held sprayer unit with a hose. riority Not Set esolution Not Set rogress Not Set ,assignment Not Set $385 $0.00 Record Number 46473 Shower In Unisex Restroom Next To Cheifs Bedroom The controls on the showers hand held mount are not accessible. ADA 4.21 rovide accessible controls on the hand held mount. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $540 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 322 of 853 Record Number 46489 Shower In Unisex Restroom Next To Weight Room There are not enough accessible showers with respect to the total number of showers available. Finding None Found Code At least 1.00 showers ADA 4.21.2, CA 11B-213.3.6 rovide the required amount of compliant accessible showers. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $4,500 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46455 Reception Vending Machine The forward reach height of the controls on the vending machine is greater than the allowed maximum height. Finding 55.87 inches Code Up to 48.00 inches ADA 4.2.5 Contact the owner of the vending machines to obtain accessible vending machines. riority Not Set esolution Not Set 'rogress Not Set ssignment Not Set $0.00 Record Number 46456 Reception Vending Machine The controls of the vending machine require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.2.5 Replace controls of vending machine with those that allow aeration with one hand and does not require tight grasping, inching, or twisting of the wrist. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $550 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 323 of 853 La Quinta Library Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43481 Parking Lot There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Record Number 43482 Parking Lot Left Accessible Space At The Main Entrance The accessible parking space does not meet the minimum requirements for width. Finding 105.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43483 Parking Lot Left Accessible Space At The Main Entrance There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 )stall a wheel stop at the head of the accessible parking space. °riority Three esolution Not Set rogress Not_Started ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 324 of 853 Record Number 43484 Parking Lot Left Accessible Space At The Main Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43486 Parking Lot Left Accessible Space At The Main Entrance The designated accessible parking space does not provide accessible signage at the head of the space. Finding None Found ADA 4.6.4 rovide compliant sigange at the accessible space. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Record Number 43487 Parking Lot Left Accessible Space At The Main Entrance There is no additional signage marked "van accessible" at the van accessible parking space. Finding None Found ADA 4.6.4 Van accessible parking spaces shall provide additional signage 'at states "van accessible" . Priority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 325 of 853 Record Number 43485 Parking Lot Left Accessible Space At The Main Entrance The surface identification at the designated accessible parking space is not compliant. Finding 51.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43488 Parking Lot Left Accessible Space At The Main Entrance The access aisle does not meet the minimum required width. Finding 95.50 inches Code At least 96.00 inches ADA 4.1.2(5) De -stripe the access aisle. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43489 Parking Lot Center Accessible Space At The Main Entrance The accessible parking space does not meet the minimum requirements for width. Finding 104.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 De -stripe the accessible parking space. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 326 of 853 Record Number 43490 Parking Lot Center Accessible Space At The Main Entrance There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 stall a wheel stop at the head of the accessible parking space. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43491 Parking Lot Center Accessible Space At The Main Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 -'rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. Priority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Record Number 43493 Parking Lot Center Accessible Space At The Main Entrance The designated accessible parking space does not provide accessible signage at the head of the space. Finding None Found ADA 4.6.4 rovide compliant sigange at the accessible space. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 327 of 853 Record Number 43494 Parking Lot Center Accessible Space At The Main Entrance There is no additional signage marked "van accessible" at the van accessible parking space. Finding None Found ADA 4.6.4 an accessible parking spaces shall provide additional signage 'at states "van accessible" . riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43492 Parking Lot Center Accessible Space At The Main Entrance The surface identification at the designated accessible parking space is not compliant. Finding 50.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 °rovide compliant surface identification at the accessible parking Dace. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43495 Parking Lot Right Accessible Space At The Main Entrance There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 Install a wheel stop at the head of the accessible parking space. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 328 of 853 Record Number 43496 Parking Lot Right Accessible Space At The Main Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43497 Parking Lot Right Accessible Space At The Main Entrance The surface identification at the designated accessible parking space is not compliant. Finding 50.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. tiority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43498 Parking Lot Right Accessible Space At The Main Entrance The designated accessible parking space does not provide accessible signage at the head of the space. Finding None Found ADA 4.6.4 rovide compliant sigange at the accessible space. tiority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 329 of 853 Record Number 43442 Curb Ramp From Left Access Aisle The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Five esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $248 $0.00 Record Number 43443 Curb Ramp From Left Access Aisle The slope of the curb ramp left side flare is greater than allowed. Finding 12.40 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 rovide curb ramp side flares with a compliant slope. riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43449 Curb Ramp From Right Access Aisle The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 Provide compliant detectable warnings to surface. riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 330 of 853 Record Number 43450 Curb Ramp From Right Access Aisle The running slope is greater than allowed. Finding 8.80 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 rovide a compliant curb ramp. riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43451 Curb Ramp From Right Access Aisle The slope of the curb ramp left side flare is greater than allowed. Finding 12.60 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 rovide curb ramp side flares with a compliant slope. riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43438 Path Of Travel Near Chamber Entrance Vegetation The leading edge of the item protrudes into the circulation route greater than permitted. Finding 27.00 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 Tnstall side extensions, modify, relocate, or lower the item so iat it is not a protruding object into the circulation route. riority Five esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $640 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 331 of 853 Record Number 43447 Path Of Travel From Parking Lot Crosswalk There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 rovide detectable warnings. riority Five .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $190 $0.00 Record Number 43448 Path Of Travel From Parking Lot Crosswalk Crosswalk is not striped. Finding None Found ADA 4.29 Crosswalk should be striped. riority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Record Number 43503 Path Of Travel From Public Right Of Way To Chamber Of Commerce Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 8.10 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. riority Five .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $3,600 $0.00 Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 332 of 853 Record Number 43440 rovide an intermediate landing so the ramp run does not Kceede its maximum distance allowed for its slope (rise). 06/30/2013 $3,168 $0.00 Ramp From Public Right Of Way To Front Entrance Run 1 The length of the ramp exceeds the maximum distance allowed for its slope (rise). Finding 492.00 inches ADA 4.8.2 riority Six .esolution Not Set rogress Not_Started Assignment Not Set Record Number 43441 Ramp From Public Right Of Way To Front Entrance Run 1 Top Landing The slope of the landing is greater than required. Finding 2.90 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-405.7.1 "1odify the landing to create a slope in any direction not Kceeding the required maximum value. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,872 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43587 Chamber Of Commerce Break Room The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 8.25 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $2,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 333 of 853 Record Number 43597 Door Between Library & Chamber Of Commerce The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 7.50 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $2,000 $0.00 Record Number 43596 Door Between Library & Chamber Of Commerce Push Bar / Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force i equirements. riority Two esolution Corrected 'rogress Completed assignment Not Set 06/30/2013 $25 $0.00 Record Number 43614 Cubicle Offices The clear opening width of the door is less than required. Finding 30.25 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 Widen the door opening and install a door that provides at least the minimum clear width with the door open 90 degrees. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 334 of 853 Record Number 43615 Cubicle Offices Lever Door hardware is not mounted at the correct height. Finding 44.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. tiority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $280 $0.00 Record Number 43446 Outside Mens Restroom Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 49.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the pull side of le door. tiority Four .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $2,921 $0.00 Record Number 43445 Outside Mens Restroom The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 335 of 853 Record Number 43444 Outside Mens Restroom Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. tiority Four esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $400 $0.00 Record Number 43480 North Entrance The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "lodify or replace the threshold to provide the recommended eight. tiority Four esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $436 $0.00 Record Number 43479 North Entrance Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. tiority Two esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 336 of 853 Record Number 43502 Outside Womens Restroom Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 50.12 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the pull side of le door. riority Four .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43501 Outside Womens Restroom The height of the threshold at the entrance door is greater than allowed. Finding 0.87 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "lodify or replace the threshold to provide the recommended eight. riority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $436 $0.00 Record Number 43500 Outside Womens Restroom Push / Pull The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Install a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Corrected 'rogress Completed _.ssignment Not Set 06/30/2013 07/25/2014 $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 337 of 853 Record Number 43595 Chamber Of Commerce Entrance Pull Side There is no level landing at this door. Finding 2.80 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. tiority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43594 Chamber Of Commerce Entrance Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. tiority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $25 $0.00 Record Number 43606 Gate To Chamber Of Commerce Entrance Pull Side There is no level landing at this door. Finding 2.80 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 ovide a level landing. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 338 of 853 Record Number 43605 Gate To Chamber Of Commerce Entrance None The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $400 $0.00 Record Number 43617 Gate To Garden Pull Side There is no level landing at this door. Finding 7.10 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 °rovide a level landing. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43616 Gate To Garden None The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Install a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four esolution Corrected rogress Completed _.ssignment Not Set 06/30/2013 07/25/2014 $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 339 of 853 Record Number 43546 Storytime Room Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $25 $0.00 Record Number 43547 Storytime Room Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $50 $0.00 Record Number 43549 Mens Restroom Near North Entrance Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 340 of 853 Record Number 43548 Mens Restroom Near North Entrance Push / Pull Door hardware is not mounted at the correct height. Finding 49.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Corrected 'rogress Completed assignment Not Set 06/30/2013 07/25/2014 $280 $0.00 Record Number 43551 Hallway Conference Room Door Push Bar / Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $25 $0.00 Record Number 43552 Hallway Conference Room Door Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 341 of 853 Record Number 43553 Womens Restroom Near North Entrance Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $25 $0.00 Record Number 43554 Womens Restroom Near North Entrance Push / Pull Door hardware is not mounted at the correct height. Finding 46.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $280 $0.00 Record Number 43569 Room 110 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 45.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 342 of 853 Record Number 43567 Room 110 Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43568 Room 110 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43589 Young Adult Room The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 8.00 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $2,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 343 of 853 Record Number 43588 Young Adult Room Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2025 $25 $0.00 Record Number 43598 Door From Library To Conference Room The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 8.00 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $2,000 $0.00 Record Number 43608 Directors Office Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 59.37 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 Provide the recommended clear floor space on the pull side of the door. riority Five .esolution Not Set 'rogress Not_Started ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 344 of 853 Record Number 43632 Bookstore Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 07/25/2014 $25 $0.00 Record Number 43633 Literacy Office & Tutoring Room 1 The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 8.50 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $2,000 $0.00 Record Number 43634 Door To Garden Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force requirements. riority Two .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 345 of 853 Record Number Door To Garden Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 43635 emove the door stop. riority Two .esolution Corrected rogress Completed assignment Not Set 06/30/2013 $50 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43583 Reception Counter The height of the counter or desk does not comply with height requirements. Finding 48.00 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 provide a portion of counter at the compliant height. riority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $3,500 $0.00 Record Number 43584 Reception Counter The counter is a protruding object. Finding See Above ADA 4.32.4, ADA 7.2 Adjust the counter so that it is no longer a protruding object. riority Four .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $450 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 346 of 853 Record Number 43639 Door Between Library & Chamber Of Commerce There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43640 Cubicle Offices There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43641 Chamber Of Commerce Break Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 347 of 853 Record Number 43499 Directional Signage From Public Right Of Way There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Corrected rogress Completed Assignment Not Set 07/25/2014 07/25/2014 $158 $0.00 Record Number 43504 North Entrance There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43586 Chamber Of Commerce Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 install accessible room signage. °riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 348 of 853 Record Number 43604 South Main Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Three .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43534 Room 110 The accessible element/identification signage attached to the wall does not include Braille characters. Finding None Found ADA 4.30.4, CA 11B-703.3 (stall accessible signage to include Grade 2 Braille characters. riority Three .esolution Corrected rogress Completed ,assignment Not Set 06/30/2013 $50 $0.00 Record Number 43536 Room 110 The accessible element/identification signage attached to the wall does not include raised lettering or numbering. Finding None Found ADA 4.30.4, CA 11B-703.2.1 (stall accessible signage that includes raised UPPERCASE tters and/or numbers between 5/8 inch and 2 inches in height riority Three .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 349 of 853 Record Number 43535 Room 110 The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 62.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Three .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43533 Room 110 Braille is not located below the raised letters. Finding None Found ADA 4.4.2, CA 11B-703.3.2 Make sure that braille is located below the raised letters. riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43570 Emergency Exits There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 Install compliant room identification signage. riority Three esolution Corrected 'rogress Completed .ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 350 of 853 Record Number 43576 Storytime Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43600 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43601 Door To Garden There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. °riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 351 of 853 Record Number 43609 Conference Room, Young Adult Room, Bookstore, Tutoring Room & Literacy Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three .esolution Corrected rogress Completed _,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43613 Directional Signage To Restroom Near Childrens Area There is signage suspended or projected overhead. The size of the lettering is less than required or cannot be viewed at a practical distance. Finding 2.25 inches Code At least 3.00 inches ADA 4.30.3, CA 11B-703.5.5, CA 11B-703.2.5 (stall accessible signage with lettering sized according to ewing distance. riority Three .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43452 Outside Womens Restroom The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 rovide a compliant door lock for the door that does not require 3ht grasping, pinching, or twisting of the wrist to operate. riority Four .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 352 of 853 Record Number 43454 Outside Womens Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.00 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required iron height. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43455 Outside Womens Restroom Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 16.62 inches on center Code At least 18.00 inches on center CA 11B-606.6 °eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Six .esolution Not Set rogress Not_Started assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43457 Outside Womens Restroom The signage is not mounted at the required height. Finding 58.50 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. riority Seven .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 353 of 853 Record Number 43456 Outside Womens Restroom Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Two esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43453 Outside Womens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43458 Outside Mens Restroom The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 Provide a compliant door lock for the door that does not require ght grasping, pinching, or twisting of the wrist to operate. riority Four esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 354 of 853 Record Number 43461 Outside Mens Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 27.12 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required iron height. tiority Six esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $2,500 $0.00 Record Number 43462 Outside Mens Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Tnsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Two esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $149 $0.00 Record Number 43463 Outside Mens Restroom Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 355 of 853 Record Number 43464 Outside Mens Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three .esolution Corrected rogress Completed _,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43459 Outside Mens Restroom Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43460 Outside Mens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Four .esolution Corrected 'rogress Completed _assignment Not Set 06/30/2013 07/25/2014 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 356 of 853 Record Number 43469 Outside Mens Restroom The door to the compartment designated to be accessible in the restroom does not have appropriate accessible hardware. Finding Not Accessible ADA 4.13.9, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7, CA 11B-6 04.8.1.2 (stall accessible hardware on the compartment door that does Dt require tight grasping, pinching, or twisting of the wrist. priority Three .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 $289 $0.00 Record Number 43468 Outside Mens Restroom The height of the side grab bar is not at the correct height. Finding 32.75 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 Remount the grab bar so it is at the correct height. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43465 Outside Mens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.62 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 357 of 853 Record Number 43467 Outside Mens Restroom The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. tiority Six .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $127 $0.00 Record Number 43471 Outside Womens Restroom The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Four .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $277 $0.00 Record Number 43470 Outside Womens Restroom The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Four .esolution Corrected rogress Completed .assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 358 of 853 Record Number 43478 Outside Womens Restroom The door to the compartment designated to be accessible in the restroom does not have appropriate accessible hardware. Finding Not Accessible ADA 4.13.9, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7, CA 11B-6 04.8.1.2 (stall accessible hardware on the compartment door that does Dt require tight grasping, pinching, or twisting of the wrist. °riority Four .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 $289 $0.00 Record Number 43476 Outside Womens Restroom The height of the side grab bar is not at the correct height. Finding 32.87 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 Remount the grab bar so it is at the correct height. riority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43477 Outside Womens Restroom The grab bar on the rear wall is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 359 of 853 Record Number 43473 Outside Womens Restroom The height of the toilet seat is not at the required height. Finding 16.25 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. tiority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,707 $0.00 Record Number 43472 Outside Womens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.25 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43475 Outside Womens Restroom The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. tiority Six .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $127 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 360 of 853 Record Number 43516 Mens Restroom Near North Entrance The coat hook is not mounted at the correct height. Finding 49.00 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $50 $0.00 Record Number 43513 Mens Restroom Near North Entrance The compartment door hardware is not at a compliant height. Finding 45.25 inches Code Up to 44.00 inches ADA 4.17.5, ADA 404.2.7, CA 11B-404.2.7, CA 11B-604.8.1.2 emove and relocate the door hardware. riority Four esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $269 $0.00 Record Number 43512 Mens Restroom Near North Entrance Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $269 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 361 of 853 Record Number 43514 Mens Restroom Near North Entrance The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Four esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43515 Mens Restroom Near North Entrance There is less than the required latch side clearance on the pull side of the door. Finding 4.25 inches Code At least 18.00 inches ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404 rovide required latch side clearance on the pull side of the Dor. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,200 $0.00 Record Number 43509 Mens Restroom Near North Entrance The height of the side grab bar is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. °riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 362 of 853 Record Number 43508 Mens Restroom Near North Entrance The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 1.25 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43510 Mens Restroom Near North Entrance The distance from the side wall to the rear grab bar is greater than allowed. Finding 6.25 inches Code Up to 6.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2 emount the rear grab bar at a compliant location. riority Three esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $78 $0.00 Record Number 43511 Mens Restroom Near North Entrance The grab bar on the rear wall is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 363 of 853 Record Number 43507 Mens Restroom Near North Entrance The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.12 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43505 Mens Restroom Near North Entrance The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 20.25 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43517 Mens Restroom Near North Entrance The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required stance from the front edge of the toilet seat. tiority Three .esolution Corrected 'rogress Completed .,ssignment Not Set 06/30/2013 $78 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 364 of 853 Record Number 43520 Mens Restroom Near North Entrance The height of the urinal rim in the restroom is not compliant. Finding 17.25 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 )wer the urinal designated to be accessible in the restroom so 'at the rim height is compliant. tiority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,397 $0.00 Record Number 43522 Mens Restroom Near North Entrance The signage is not mounted at the required height. Finding 59.50 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Dst compliant signage at the restroom. riority Seven .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43523 Mens Restroom Near North Entrance There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. tiority Three .esolution Corrected 'rogress Completed .,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 365 of 853 Record Number 43518 Mens Restroom Near North Entrance Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. tiority Two .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43519 Mens Restroom Near North Entrance Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Two .esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $149 $0.00 Record Number 43521 Mens Restroom Near North Entrance Male The gender use signage on the entrance door is not mounted at the required height. Finding 58.62 inches Code 60.00 inches CA 11B-703.7.2.6 Post gender use signage on the center of the door at the required height. riority Seven .esolution Corrected rogress Completed .ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 366 of 853 Record Number 43532 Womens Restroom Near North Entrance The coat hook is not mounted at the correct height. Finding 48.50 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $50 $0.00 Record Number 43529 Womens Restroom Near North Entrance The compartment door hardware is not at a compliant height. Finding 45.00 inches Code Up to 44.00 inches ADA 4.17.5, ADA 404.2.7, CA 11B-404.2.7, CA 11B-604.8.1.2 emove and relocate the door hardware. riority Six esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $269 $0.00 Record Number 43528 Womens Restroom Near North Entrance Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Six esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $269 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 367 of 853 Record Number 43530 Womens Restroom Near North Entrance The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Six esolution Corrected rogress Completed Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43531 Womens Restroom Near North Entrance There is less than the required latch side clearance on the pull side of the door. Finding 4.50 inches Code At least 18.00 inches ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404 rovide required latch side clearance on the pull side of the Dor. riority Six .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $2,200 $0.00 Record Number 43527 Womens Restroom Near North Entrance The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 1.25 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. riority Seven .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 368 of 853 Record Number 43524 Womens Restroom Near North Entrance The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.87 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43526 Womens Restroom Near North Entrance The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43542 Womens Restroom Near Childrens Area Lavatory The height of the counter surface is greater than allowed. Finding 35.62 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Five .esolution Corrected 'rogress Completed .ssignment Not Set 06/30/2013 $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 369 of 853 Record Number 43541 Womens Restroom Near Childrens Area Lavatory The faucet controls on the lavatory require tight grasping, pinching, or twisting of the wrist and are not accessible. Finding Not Accessible ADA 4.19.5, ADA 309.4, CA 11B-309.4, CA 11B-213, CA 11B-606 (stall accessible faucet controls on the lavatory. riority Six esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $392 $0.00 Record Number 43544 Womens Restroom Near Childrens Area The signage is not mounted at the required height. Finding 61.12 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. riority Seven esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43545 Womens Restroom Near Childrens Area There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three esolution Corrected 'rogress Completed .,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 370 of 853 Record Number 43543 Womens Restroom Near Childrens Area Female The gender use signage on the entrance door is not mounted at the required height. Finding 61.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Seven .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43558 Womens Restroom Near Childrens Area The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 1.25 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 °rovide a grab bar that has a compliant gripping surface meets I other requirements. riority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $250 $0.00 Record Number 43559 Womens Restroom Near Childrens Area The height of the side grab bar is not at the correct height. Finding 33.12 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 ^emount the grab bar so it is at the correct height. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 371 of 853 Record Number 43560 Womens Restroom Near Childrens Area The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required (stance from the front edge of the toilet seat. riority Three esolution Corrected rogress Completed .ssignment Not Set 06/30/2013 07/25/2014 $78 $0.00 Record Number 43555 Womens Restroom Near Childrens Area The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43557 Womens Restroom Near Childrens Area The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 31.62 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 372 of 853 Record Number 43564 Mens Restroom Near Childrens Area The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 1.37 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43565 Mens Restroom Near Childrens Area The distance from the back wall to the front of the grab bar is less than required. Finding 53.75 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43566 Mens Restroom Near Childrens Area The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required stance from the front edge of the toilet seat. tiority Three .esolution Corrected 'rogress Completed .,ssignment Not Set 06/30/2013 07/25/2014 $78 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 373 of 853 Record Number 43561 Mens Restroom Near Childrens Area The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.62 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43563 Mens Restroom Near Childrens Area The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 32.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43572 Mens Restroom Near Childrens Area The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 374 of 853 Record Number 43571 Mens Restroom Near Childrens Area Lavatory The height of the counter surface is greater than allowed. Finding 36.00 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. tiority Six .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $1,286 $0.00 Record Number 43573 Mens Restroom Near Childrens Area Male The gender use signage on the entrance door is not mounted at the required height. Finding 59.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. tiority Seven .esolution Corrected 'rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43574 Mens Restroom Near Childrens Area The signage is not mounted at the required height. Finding 62.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Dst compliant signage at the restroom. riority Three .esolution Corrected rogress Completed _,ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 375 of 853 Record Number 43575 Mens Restroom Near Childrens Area There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Corrected rogress Completed .ssignment Not Set 06/30/2013 07/25/2014 $158 $0.00 Record Number 43579 Womens Restroom Near North Entrance Female The gender use signage on the entrance door is not mounted at the required height. Finding 58.50 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43580 Womens Restroom Near North Entrance Female The restroom signage is not compliant. Finding None Found CA 11B-703.7.2.6.2 rovide compliant restroom signage. riority Three .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 376 of 853 Record Number 43577 Womens Restroom Near North Entrance Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.62 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,286 $0.00 Record Number 43578 Womens Restroom Near North Entrance Lavatory There is not enough toe clearance at the restroom lavatory. Finding 1.00 inches Code At least 9.00 inches ADA 4.19.2 °rovide minimum required toe clearance. riority Six .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $289 $0.00 Record Number 43581 Womens Restroom Near North Entrance The signage is not mounted at the required height. Finding 59.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Tost compliant signage at the restroom. riority Seven .esolution Corrected rogress Completed _,ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 377 of 853 Record Number 43582 Womens Restroom Near North Entrance There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Corrected rogress Completed .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43610 Unisex Staff Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $804 $0.00 Record Number 43611 Unisex Staff Restroom Lavatory The faucet controls on the lavatory require tight grasping, pinching, or twisting of the wrist and are not accessible. Finding Not Accessible ADA 4.19.5, ADA 309.4, CA 11B-309.4, CA 11B-213, CA 11B-606 (stall accessible faucet controls on the lavatory. riority Six .esolution Corrected rogress Completed _assignment Not Set 06/30/2013 07/25/2014 $392 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 378 of 853 Record Number 43612 Unisex Staff Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $1,286 $0.00 Record Number 43625 Unisex Staff Restroom The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 46.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 °elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Four .esolution Corrected 'regress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $277 $0.00 Record Number 43624 Unisex Staff Restroom The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Three .esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 379 of 853 Record Number 43630 Unisex Staff Restroom The coat hook is not mounted at the correct height. Finding 67.37 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Three esolution Corrected rogress Completed Assignment Not Set 06/30/2013 07/25/2014 $50 $0.00 Record Number 43629 Unisex Staff Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 53.87 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43631 Unisex Staff Restroom The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 12.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Three esolution Corrected 'rogress Completed Assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 380 of 853 Record Number 43626 Unisex Staff Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.87 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43628 Unisex Staff Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 31.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Libraries Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43618 Adult Library The space between book shelves is less than required value. Finding 39.50 inches Code At least 44.00 inches ADA 8.5, CA 11B-403.5.1 (crease the space between shelves to the recommended value. riority Five .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $2,160 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 381 of 853 Record Number 43638 Childrens Library The knee clearance height at the table for use primarily by children is not compliant. Finding 20.25 inches Code At least 24.00 inches ADA 4.32.5(2) rovide a compliant table for use primarily by children. riority Five esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $174 $0.00 Record Number 43637 Childrens Library The height of the checkout counter is used primarily by children is not compliant. Finding 30.37 inches Code Up to 30.00 inches ADA 7.2, ADA 8.3, CA 11B-902.4.2 ake sure a portion of the counter is within compliant height inges to accommodate age group requirements for children. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $545 $0.00 Record Number 43636 Childrens Library The space between book shelves is less than required value. Finding 41.25 inches Code At least 44.00 inches ADA 8.5, CA 11B-403.5.1 (crease the space between shelves to the recommended value. °riority Five esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,160 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 382 of 853 Record Number 43607 Visual Alarms There are some visual warning devices, though visual warning devices are not located throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, classrooms and eneral use rooms, accessible restrooms and other accessible )oms. riority Six .esolution Corrected rogress Completed ,ssignment Not Set 06/30/2013 07/25/2014 $2,200 $0.00 Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43619 Chamber Of Commerce Break Room No visual alarms found at the location. Finding None Found ADA 4.27 'rovide visual alarms at the location. tiority Seven esolution Not Set 'rogress Not_Started ssignment Not Set 06/30/2013 07/25/2014 $388 $0.00 Record Number 43620 Chamber Of Commerce Break Room Sink counter height does not meet the standards. Finding 35.75 inches Code Up to 34.00 inches CA 11B-606.3 ^rovide compliant sink. tiority Six esolution Not Set 'rogress Not_Started ssignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 383 of 853 Record Number 43621 Chamber Of Commerce Break Room The toe kick for the sink in break/conference room is not removed. Finding Not Removed CA 11B-606.2, CA 11B-305, CA 11B-306 emove the toe kick for the sink. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $612 $0.00 Record Number 43622 Chamber Of Commerce Break Room The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain ipes under the sink to protect against contact. Make certain iere are no sharp or abrasive surfaces under the sink. riority Two .esolution Not_Corrected 'rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Record Number 43623 Chamber Of Commerce Break Room Microwave Appliance Reach Height in the break/conference room is not compliant. Finding 64.25 inches Code Up to 48.00 inches CA 11B-308, CA 11B-309, CA 11B-205 ake sure that the specified appliance reach height is )mpliant. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 384 of 853 Record Number 43537 Conference Room The table knee clearance does not meet required standards. Finding 26.87 inches Code At least 27.00 inches CA 11B-902.2, CA 11B-305, CA 11B-306 rovide compliant tables. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43538 Conference Room The table knee width does not meet required standards. Finding 29.50 inches Code At least 30.00 inches ADA 4.27 rovide compliant tables. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,174 $0.00 Record Number 43539 Conference Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 install an International Symbol of Accessibility at the table. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 385 of 853 Record Number 43540 Conference Room There is not enough clear floor space at the table. Finding 29.50 inches Code At least 30.00 inches ADA 4.27 rovide compliant clear floor space at the table. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43592 Library Staff Break Room Sink counter height does not meet the standards. Finding 36.00 inches Code Up to 34.00 inches CA 11B-606.3 rovide compliant sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Record Number 43590 Library Staff Break Room The table knee depth does not meet required standards. Finding 6.00 inches Code At least 19.00 inches ADA 4.27, CA 11B-306, CA 11B-902 Provide compliant tables. priority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $2,174 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 386 of 853 Record Number 43591 Library Staff Break Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43593 Library Staff Break Room Microwave Appliance Reach Height in the break/conference room is not compliant. Finding 68.50 inches Code Up to 48.00 inches CA 11B-308, CA 11B-309, CA 11B-205 ake sure that the specified appliance reach height is )mpliant. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,200 $0.00 Record Number 43602 Young Adult Room The table knee depth does not meet required standards. Finding 4.00 inches Code At least 19.00 inches ADA 4.27, CA 11B-306, CA 11B-902 rovide compliant tables. riority Seven .esolution Not Set 'rogress Not_Started _,ssignment Not Set 06/30/2013 $2,174 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 387 of 853 Record Number 43603 Young Adult Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $158 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43550 Room 110 Sink counter height is not compliant. Finding 35.75 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 provide compliant sink. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $1,800 $0.00 Lockers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43585 Staff Lockers No accessible lockers were found. Finding Not Available CA 11B-225.2.1, CA 11B-811 rovide a compliant amount of accessible lockers. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 388 of 853 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43439 Library Book Return Book Return - Other The highest point of operation for the element is not compliant. Finding 51.25 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the commended value. riority Seven .esolution Not Set 'rogress Not_Started .assignment Not Set 06/30/2013 $50 $0.00 Record Number 43599 Adult Library Copy Machine - Other The highest point of operation for the element is not compliant. Finding 0.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 Make sure that the highest point of operation is within the recommended value. riority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 389 of 853 La Quinta Museum Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43948 Parking At Museum There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $250 $0.00 Record Number 43950 Parking At Museum Right Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 100.25 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $350 $0.00 Record Number 43951 Parking At Museum Right Accessible Space The slope of the accessible parking space is not compliant. Finding 2.80 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. riority Seven .esolution Not Set rogress Not_Started assignment Not Set $3,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 390 of 853 Record Number 43952 Parking At Museum Right Accessible Space The accessible parking space does not meet the minimum requirement for length. Finding 185.50 inches Code At least 216.00 inches CA 11B-502.2 e-stripe the accessible parking space. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $350 $0.00 Record Number 43949 Parking At Museum Right Accessible Space The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 Re -stripe the existing parking space marked as accessible to 'efine the width of the space. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $350 $0.00 Record Number 43953 Parking At Museum Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 391 of 853 Record Number 43955 Parking At Museum Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 48.50 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $220 $0.00 Record Number 43954 Parking At Museum Right Accessible Space ISA surface identification is faded and not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.6.4 °epaint the ISA surface identification in the parking space. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $117 $0.00 Record Number 43956 Parking At Museum Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 107.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 De -stripe the accessible parking space. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 392 of 853 Record Number 43957 Parking At Museum Left Accessible Space The slope of the accessible parking space is not compliant. Finding 2.80 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. tiority Seven esolution Not Set 'regress Not_Started assignment Not Set $3,800 $0.00 Record Number 43958 Parking At Museum Left Accessible Space The accessible parking space does not meet the minimum requirement for length. Finding 188.00 inches Code At least 216.00 inches CA 11B-502.2 e-stripe the accessible parking space. tiority Three esolution Not Set 'regress Not_Started ,ssignment Not Set $350 $0.00 Record Number 43959 Parking At Museum Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Three esolution Not Set 'rogress Not_Started .ssignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 393 of 853 Record Number 43960 Parking At Museum Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 48.50 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $220 $0.00 Record Number 43962 Parking At Museum Left Accessible Space The slope of the access aisle is not compliant. Finding 3.00 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 °epave the access aisle to provide a compliant surface slope. riority Seven .esolution Not Set 'regress Not_Started Assignment Not Set $3,800 $0.00 Record Number 43963 Parking At Museum Left Accessible Space The access aisle markings are faded, damaged, or otherwise not viewable. Finding None Found CA 11B-502.3 De -stripe the access aisle so as to discourage parking. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 394 of 853 Record Number 43964 e-stripe the hatched lines in a contrasting color at a compliant (stance on center. $350 $0.00 Parking At Museum Left Accessible Space The hatched lines are striped a noncompliant distance on center. Finding Not on 36" center CA 11B-502.3.3 riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43941 Curb Ramp At The Head Of The Access Aisle The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 provide compliant detectable warnings to surface. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $248 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43927 Path Of Travel At 2nd Floor Balcony Lights The vertical clearance height is less than required. Finding 76.00 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307.4 rovide recommended vertical clearance. riority Seven .esolution Not Set rogress Not_Started assignment Not Set $108 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 395 of 853 Record Number 43939 Path Of Travel In Courtyard Lights The vertical clearance height is less than required. Finding 76.00 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307.4 rovide recommended vertical clearance. tiority Seven esolution Not Set 'rogress Not_Started assignment Not Set $108 $0.00 Record Number 43940 Path Of Travel In Courtyard Lamp Circa 1937 The vertical clearance height is less than required. Finding 78.12 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307.4 rovide recommended vertical clearance. tiority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $108 $0.00 Record Number 43938 Path Of Travel In Courtyard Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 9.20 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 Provide a compliant path of travel. tiority Five esolution Not Set 'rogress Not_Started _assignment Not Set $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 396 of 853 Record Number 43946 Path Of Travel Along Avenida Montezuma Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 3.00 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 rovide a compliant path of travel. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $3,600 $0.00 Record Number 43972 Path Of Travel From Avenida Mendoza Along Avenida Montezuma Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 3.40 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 Provide a compliant path of travel. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $3,600 $0.00 Record Number 44047 Path Of Travel To Exit Stairwell Near Alley Curb On Path Of Travel There is a curb on the designated path of travel. Finding Curb Found ADA 4.3 rovide a compliant curb ramp. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 397 of 853 Record Number 43976 (stall side extensions, modify, relocate, or lower the item so 'at it is not a protruding object into the circulation route. $640 $0.00 Path Of Travel In Entryway Donation Box The leading edge of the item protrudes into the circulation route greater than permitted. Finding 4.37 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 riority Seven .esolution Not Set rogress Not_Started Assignment Not Set Elevators Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43929 Elevator There is less than the required depth from the entrance door to the back wall of the elevator car. Finding 51.62 inches Code At least 54.00 inches ADA 4.10.9 ontact a certified elevator provider to perform all renovation quired. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $0.00 Record Number 43928 Elevator There is no signage at the elevator indicating the evacuation plan. Finding None Found ADA 4.10 rovide compliant signage indicating evacuation plan and )utes. riority Three .esolution Not Set rogress Not_Started ,ssignment Not Set $207 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 398 of 853 Record Number 43931 Elevator Elevator communication control mounting height is not compliant. Finding 31.12 inches Code 35.00 - 48.00 inches ADA 4.10.14, CA 11B-308, CA 11B-407.4.9 rovide communication controls at a compliant height. Contact certified elevator provider to perform all renovation required. tiority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,200 $0.00 Record Number 43932 Elevator The hall buttons for the elevator are not centered within the required range above the floor surface. Finding 42.12 inches Code 15.00 - 42.00 inches ADA 4.10.3 ake sure that the elevator controls are located at the )mpliant height above the finished floor. tiority Five .esolution Not Set 'rogress Not_Started Assignment Not Set $574 $0.00 Record Number 43930 Elevator The reopening device for the elevator door does not remain open for the required amount of time. Finding Not Accessible ADA 4.10.6, CA 11B-407.3.3.3 ontact a certified elevator provider to perform all renovation ?quired. Priority Five .esolution Not Set 'rogress Not_Started ,ssignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 399 of 853 Record Number 43933 Elevator The hoistway signage is not at a compliant height above the finished floor. Finding 59.75 inches on center Code 60.00 inches on center ADA 4.10.5, CA 11B-407.2.3.1 rovide compliant signage within the elevator hoistways. riority Five .esolution Not Set rogress Not_Started _,ssignment Not Set $1,500 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43880 Courtyard Stairs To 2nd Floor Run 1 There is no intermediate handrail available; the width of the stairway requires that a middle handrail is installed. Finding None Found provide an intermediate handrail spaced equally in the middle of the stair run. riority Four esolution Not Set 'rogress Not_Started ssignment Not Set $1,528 $0.00 Record Number 43881 Courtyard Stairs To 2nd Floor Run 2 The width of the stairway does not meet the minimum required width. Finding 46.00 inches Code At least 48.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 Install a stairway with a minimum width as required. riority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set $8,572 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 400 of 853 Record Number 43882 Courtyard Stairs To 2nd Floor Run 2 Right Handrail The surface texture of the wall adjacent to the handrail is sharp and abrasive. Finding Near Wall ADA 4.26.4 odify the surface texture on the wall adjacent to the handrail ) that the surface is smooth. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $2,320 $0.00 Record Number 43883 Courtyard Stairs To 2nd Floor Run 2 Right Handrail The handrail extension is not the required length. Finding 5.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.3 Tnstall a compliant extension to the handrail. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $627 $0.00 Record Number 43884 Courtyard Stairs To 2nd Floor Run 2 Left Handrail The surface texture of the wall adjacent to the handrail is sharp and abrasive. Finding Near Wall ADA 4.26.4 "^odify the surface texture on the wall adjacent to the handrail ) that the surface is smooth. riority Four esolution Not Set 'rogress Not_Started _.ssignment Not Set $2,320 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 401 of 853 Record Number 43885 Courtyard Stairs To 2nd Floor Run 3 The width of the stairway does not meet the minimum required width. Finding 46.00 inches Code At least 48.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 (stall a stairway with a minimum width as required. riority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set $8,572 $0.00 Record Number 43886 Courtyard Stairs To 2nd Floor Run 3 Left Handrail The surface texture of the wall adjacent to the handrail is sharp and abrasive. Finding Near Wall ADA 4.26.4 Modify the surface texture on the wall adjacent to the handrail D that the surface is smooth. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,320 $0.00 Record Number 43887 Courtyard Stairs To 2nd Floor Run 3 Left Handrail The distance between the handrail and the wall on the stairway is less than required. Finding 1.37 inches Code At least 1.50 inches ADA 4.9.4(3), CA 11B-505.5 emount the handrails on the stairway so that the distance om the handrail to the adjacent wall is compliant. riority Four .esolution Not Set 'regress Not_Started ..ssignment Not Set $1,916 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 402 of 853 Record Number 43888 Courtyard Stairs To 2nd Floor Run 3 Right Handrail The gripping surface of the handrail is interrupted. Finding Interrupted ADA 4.9.4(4) emount the handrail so is not interrupted. tiority Four .esolution Not Set rogress Not_Started assignment Not Set $1,840 $0.00 Record Number 43889 Courtyard Stairs To 2nd Floor Run 3 Right Handrail The surface texture of the wall adjacent to the handrail is sharp and abrasive. Finding Near Wall ADA 4.26.4 odify the surface texture on the wall adjacent to the handrail ) that the surface is smooth. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,320 $0.00 Record Number 43890 Courtyard Stairs To 2nd Floor Run 3 Right Handrail The distance between the handrail and the wall on the stairway is less than required. Finding 1.25 inches Code At least 1.50 inches ADA 4.9.4(3), CA 11B-505.5 emount the handrails on the stairway so that the distance om the handrail to the adjacent wall is compliant. tiority Four .esolution Not Set 'rogress Not_Started ..ssignment Not Set $1,916 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 403 of 853 Record Number 43891 Courtyard Stairs To 2nd Floor Run 3 Right Handrail The bottom handrail does not extend the depth of one stair tread beyond the bottom step. Finding None Found ADA 4.9.4(2), CA 11B-505.10.3 rovide a compliant handrail extension. riority Four .esolution Not Set rogress Not_Started ,ssignment Not Set $1,425 $0.00 Record Number 44066 Exit Stairwell 111 Run 1 The stair striping is not a contrasting color. Finding None Found ADA 4.9.5, CA 11B-504.4.1 Provide compliant contrasting striping to the required treads id upper approach. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $460 $0.00 Record Number 44067 Exit Stairwell 111 Run 1 Left Handrail The handrail is not mounted at the required height. Finding 39.00 inches Code 34.00 - 38.00 inches ADA 4.9.4(5), CA 11B-504.6, CA 11B-505 ovide handrail at the required height. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $1,528 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 404 of 853 Record Number 44069 Exit Stairwell 111 Run 1 Right Handrail The handrail is not mounted at the required height. Finding 39.00 inches Code 34.00 - 38.00 inches ADA 4.9.4(5), CA 11B-504.6, CA 11B-505 rovide handrail at the required height. tiority Four .esolution Not Set 'rogress Not_Started assignment Not Set $1,528 $0.00 Record Number 44068 Exit Stairwell 111 Run 1 Right Handrail The top handrail extension is not the required length beyond the top riser. Finding 5.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 (stall a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $800 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43968 Main Entrance To Courtyard Near Avenida Mendoza Pull Side There is no level landing at this door. Finding 4.10 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 -'rovide a level landing. riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 405 of 853 Record Number 43967 Main Entrance To Courtyard Near Avenida Mendoza Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 12.00 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance for the door. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,921 $0.00 Record Number 44075 Entrance Gate To Museum Offices Push Side There is no level landing at this door. Finding 2.60 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $1,500 $0.00 Record Number 44076 Entrance Gate To Museum Offices Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 39.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. Priority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 406 of 853 Record Number 44077 Entrance Gate To Museum Offices Pull Side There is no level landing at this door. Finding 5.90 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Six .esolution Not Set 'rogress Not_Started assignment Not Set $1,500 $0.00 Record Number 44074 Entrance Gate To Museum Offices Single Knob The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Record Number 43893 Museum Store Entrance Push / Pull The door opening force for this door is greater than allowed. Finding 6.50 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 407 of 853 Record Number 43895 Museum Store Entrance Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two esolution Not Set rogress Not_Started assignment Not Set $50 $0.00 Record Number 43894 Museum Store Entrance Push / Pull Door hardware is not mounted at the correct height. Finding 52.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set $280 $0.00 Record Number 43908 Right & Left Entrance Doors To Meeting Room 106 Near Courtyard Pull Side There is no level landing at this door. Finding 2.40 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Seven esolution Not Set 'rogress Not_Started _assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 408 of 853 Record Number 43905 Right & Left Entrance Doors To Meeting Room 106 Near Courtyard Push Bar / D Handle The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Record Number 43904 Right & Left Entrance Doors To Meeting Room 106 Near Courtyard Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $25 $0.00 Record Number 43906 Right & Left Entrance Doors To Meeting Room 106 Near Courtyard Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 409 of 853 Record Number 43907 Right & Left Entrance Doors To Meeting Room 106 Near Courtyard The height of the threshold at the entrance door is greater than allowed for a vertical rise. Finding 0.37 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $257 $0.00 Record Number 43909 Meeting Room 106 Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force i equirements. riority Two .esolution Not Set 'rogress Not_Started assignment Not Set $25 $0.00 Record Number 43910 Meeting Room 106 Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 410 of 853 Record Number 43912 Entrance Doors To 1st Floor Rotunda Push Bar / D Handle The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set rogress Not_Started Assignment Not Set $400 $0.00 Record Number 43911 Entrance Doors To 1st Floor Rotunda Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $25 $0.00 Record Number 43913 Entrance Doors To 1st Floor Rotunda Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 ^emove the door stop. riority Two .esolution Not Set rogress Not_Started ,ssignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 411 of 853 Record Number 43916 Exhibit Hall 101 Entrance Near Courtyard The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 43914 Exhibit Hall 101 Entrance Near Courtyard Push Bar / Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 43915 Exhibit Hall 101 Entrance Near Courtyard Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 412 of 853 Record Number 43918 Door Between Exhibit Hall 101 & Museum Store Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 43919 Door Between Exhibit Hall 101 & Museum Store Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Record Number 43934 Classroom 103 Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected 'rogress Completed .ssignment Not Set 12/20/2014 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 413 of 853 Record Number 43935 Classroom 103 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set $50 $0.00 Record Number 43936 Archives 102 Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Corrected rogress Completed ,ssignment Not Set 10/20/2014 $25 $0.00 Record Number 43937 Archives 102 Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 414 of 853 Record Number 43942 Kitchen 107 Entrance Near Courtyard Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 43943 Kitchen 107 Entrance Near Courtyard Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Record Number 43944 Kitchen 107 Entrance Near Courtyard The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 415 of 853 Record Number 43947 Exhibit Hall 101 The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 4.00 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set $2,000 $0.00 Record Number 43966 Kitchen 107 Entrance Near Trash Area Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 22.37 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 Provide the recommended latch side clearance for the door. riority Seven esolution Not Set rogress Not_Started Assignment Not Set $2,921 $0.00 Record Number 43965 Kitchen 107 Entrance Near Trash Area The height of the threshold at the entrance door is greater than allowed. Finding 1.12 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 Modify or replace the threshold to provide the recommended neight. tiority Seven esolution Not Set rogress Not_Started .-ssignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 416 of 853 Record Number 43969 Door Between Exhibit Hall 101 & Archives 102 Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 43970 Door Between Exhibit Hall 101 & Archives 102 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Record Number 43973 Door Between Meeting Room 106 & Kitchen 107 Push / Pull The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 417 of 853 Record Number 43975 Door Between Meeting Room 106 & Kitchen 107 Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. tiority Two .esolution Not Set rogress Not_Started assignment Not Set $50 $0.00 Record Number 43974 Door Between Meeting Room 106 & Kitchen 107 Push / Pull Door hardware is not mounted at the correct height. Finding 52.25 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $280 $0.00 Record Number 43982 Exit Stairwell 111 Near Alley Push Side There is not enough clear floor space provided at the push side of the door . Finding 18.25 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. Priority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 418 of 853 Record Number 43981 Exit Stairwell 111 Near Alley Push Side There is less than the required latch side clearance on the push side of the door. Finding 10.75 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $2,921 $0.00 Record Number 43980 Exit Stairwell 111 Near Alley The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "lodify or replace the threshold to provide the recommended eight. riority Seven .esolution Not Set 'rogress Not_Started assignment Not Set $436 $0.00 Record Number 43979 Exit Stairwell 111 Near Alley Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 419 of 853 Record Number 44021 Mens Restroom 104 Push / Pull The door opening force for this door is greater than allowed. Finding 12.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 44023 Mens Restroom 104 Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Record Number 44022 Mens Restroom 104 Push / Pull Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 420 of 853 Record Number 44024 Mens Restroom 104 The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 44048 Womens Restroom 105 Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 44050 Womens Restroom 105 Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 421 of 853 Record Number 44049 Womens Restroom 105 Push / Pull Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Not Set 'rogress Not_Started assignment Not Set $280 $0.00 Record Number 44051 Womens Restroom 105 The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 43977 Exit Stairwell 111 Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 422 of 853 Record Number 43978 Exit Stairwell 111 Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set $50 $0.00 Record Number 43985 West Entrance To Exhibit Hall 200 Push / Pull The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 43987 West Entrance To Exhibit Hall 200 Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 423 of 853 Record Number 43986 West Entrance To Exhibit Hall 200 Push / Pull Door hardware is not mounted at the correct height. Finding 53.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four esolution Not Set 'rogress Not_Started assignment Not Set $280 $0.00 Record Number 44020 Unisex Restroom 206 Pull Side There is no level landing at this door. Finding 3.10 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $1,500 $0.00 Record Number 44018 Unisex Restroom 206 Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority One esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 424 of 853 Record Number 44019 Unisex Restroom 206 Push / Pull Door hardware is not mounted at the correct height. Finding 51.75 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Not Set 'rogress Not_Started assignment Not Set $280 $0.00 Record Number 44046 Entrance To Exhibit Hall 3 (204) The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Record Number 44043 Entrance To Exhibit Hall 3 (204) Push / Pull The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two esolution Not Set 'rogress Not_Started .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 425 of 853 Record Number 44045 Entrance To Exhibit Hall 3 (204) Push / Pull Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set rogress Not_Started assignment Not Set $50 $0.00 Record Number 44044 Entrance To Exhibit Hall 3 (204) Push / Pull Door hardware is not mounted at the correct height. Finding 53.25 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $280 $0.00 Record Number 44058 North Entrance To Exhibit Hall 200 Push Bar / D Handle The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 426 of 853 Record Number 44057 North Entrance To Exhibit Hall 200 Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 44059 North Entrance To Exhibit Hall 200 Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Record Number 44060 North Entrance To Exhibit Hall 200 The height of the threshold at the entrance door is greater than allowed. Finding 0.87 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 427 of 853 Record Number 44070 Door Between Exhibit Hall 3 (204) & Exit Stairwell Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 44071 Door Between Exhibit Hall 3 (204) & Exit Stairwell Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Record Number 43984 Left Office The clear opening width of the doorway is not compliant. Finding 29.12 inches Code At least 32.00 inches ADA 4.13.5 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Six .esolution Not Set 'rogress Not_Started .,ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 428 of 853 Record Number 43983 Left Office The vertical clearance height of the open doorway is not compliant. Finding 78.25 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. riority Six esolution Not Set rogress Not_Started _,ssignment Not Set $5,600 $0.00 Record Number 44009 Main Entrance Near Avenida Montezuma & Avenida Mendoza Push Side There is not enough clear floor space provided at the push side of the door . Finding 39.00 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $4,000 $0.00 Record Number 44010 Main Entrance Near Avenida Montezuma & Avenida Mendoza Push Side There is no level landing at this door. Finding 3.20 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 429 of 853 Record Number 44007 Main Entrance Near Avenida Montezuma & Avenida Mendoza Push Side There is less than the required latch side clearance on the push side of the door. Finding 7.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,921 $0.00 Record Number 44008 Main Entrance Near Avenida Montezuma & Avenida Mendoza Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 12.00 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 °rovide the recommended latch side clearance for the door. Priority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,921 $0.00 Record Number 44005 Main Entrance Near Avenida Montezuma & Avenida Mendoza The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 9.00 inches Code At least 10.00 inches CA 11B-404.2.10 Install a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Four .esolution Not Set 'rogress Not_Started ssignment Not Set $2,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 430 of 853 Record Number 44003 Main Entrance Near Avenida Montezuma & Avenida Mendoza Twist / Thumb Latch The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Six .esolution Not Set rogress Not_Started assignment Not Set $800 $0.00 Record Number 44004 Main Entrance Near Avenida Montezuma & Avenida Mendoza Twist / Thumb Latch The door opening force for this door is greater than allowed. Finding 11.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $25 $0.00 Record Number 44006 Main Entrance Near Avenida Montezuma & Avenida Mendoza The height of the threshold at the entrance door is greater than allowed. Finding 2.12 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 431 of 853 Record Number 44025 Center Office The clear opening width of the door is less than required. Finding 27.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,750 $0.00 Record Number 44026 Center Office The vertical clearance height of the door is less than required. Finding 78.12 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 tend the height of the doorway to provide the required earance height. riority Five .esolution Not Set 'rogress Not_Started .ssignment Not Set $2,000 $0.00 Record Number 44028 Center Office Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 17.00 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 432 of 853 Record Number 44027 Center Office Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Three esolution Not Set rogress Not_Started assignment Not Set $800 $0.00 Record Number 44073 Right Office The clear opening width of the doorway is not compliant. Finding 29.12 inches Code At least 32.00 inches ADA 4.13.5 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Seven esolution Not Set 'rogress Not_Started .ssignment Not Set $1,800 $0.00 Record Number 44072 Right Office The vertical clearance height of the open doorway is not compliant. Finding 78.00 inches Code At least 80.00 inches ADA 4.13.5 Provide a compliant open doorway at the location. tiority Seven esolution Not Set rogress Not_Started Assignment Not Set $5,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 433 of 853 Record Number 44078 Unisex Restroom The clear opening width of the door is less than required. Finding 25.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,750 $0.00 Record Number 44079 Unisex Restroom The vertical clearance height of the door is less than required. Finding 78.50 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 tend the height of the doorway to provide the required earance height. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $2,000 $0.00 Record Number 44082 Unisex Restroom Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 17.50 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 434 of 853 Record Number 44083 Unisex Restroom Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 21.25 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Six .esolution Not Set 'regress Not_Started Assignment Not Set $2,921 $0.00 Record Number 44080 Unisex Restroom Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 °rovide accessible hardware on the door. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $800 $0.00 Record Number 44081 Unisex Restroom Single Knob Door hardware is not mounted at the correct height. Finding 51.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 "'bunt the door hardware at the recommended height. tiority Six .esolution Not Set 'regress Not_Started ,ssignment Not Set $280 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 435 of 853 Record Number 43917 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43877 Kitchen 107 Doors There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43879 Museum Store & Exhibit Hall 101 Doors There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. °riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 436 of 853 Record Number 43892 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43898 North Main Entrance To 1st Floor Rotunda There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43899 Meeting Room 106 The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 59.00 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 437 of 853 Record Number 43945 Entrance Doors To 1st Floor Rotunda There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43971 Classroom 103 & Archives 102 Doors There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43988 Entrance To Exhibit Hall 3 (204) The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 60.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. tiority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 438 of 853 Record Number 43989 Exit Stairwell 111 There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 44002 Entrance Doors To Exhibit Hall 200 There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44033 Mens Restroom 104 The shields extend greater than 24" in front of the urinal. The width between the shields is less than required. Finding 32.12 inches Code At least 36.00 inches ADA 4.18.2, CA 11B-605.3, CA 11B-305.7 modify or replace the urinal shields in the restroom to provide ie required clearance between the shields for the urinal 2signated as accessible. riority Six esolution Not Set rogress Not_Started ,ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 439 of 853 Record Number 44034 Mens Restroom 104 Male The gender use signage on the entrance door is not mounted at the required height. Finding 61.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 44035 Mens Restroom 104 Male The restroom signage is not compliant. Finding None Found CA 11B-703.7.2.6.1 °rovide compliant restroom signage. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 44036 Mens Restroom 104 The signage is not mounted at the required height. Finding 61.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Tost compliant signage at the restroom. riority Three .esolution Not Set rogress Not_Started _,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 440 of 853 Record Number 44031 Mens Restroom 104 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.75 inches Code At least 29.00 inches CA 11B-306.3.3, CA 118-606.2 aise or replace the lavatory to provide the minimum required iron height. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 44032 Mens Restroom 104 Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $1,286 $0.00 Record Number 44030 Mens Restroom 104 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 441 of 853 Record Number 44039 Womens Restroom 105 The distance from the back wall to the front of the grab bar is less than required. Finding 53.50 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 44040 Womens Restroom 105 The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 22.25 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 44037 Womens Restroom 105 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 442 of 853 Record Number 44041 Womens Restroom 105 The toilet paper dispenser is not mounted at the required height. Finding 16.87 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Record Number 44042 Womens Restroom 105 The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required stance from the front edge of the toilet seat. tiority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $78 $0.00 Record Number 44056 Womens Restroom 105 The signage is not mounted at the required height. Finding 62.50 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. °riority Three .esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 443 of 853 Record Number 44055 Womens Restroom 105 Female The gender use signage on the entrance door is not mounted at the required height. Finding 61.00 inches Code 60.00 inches CA 11B-703.7.2.6 3st gender use signage on the center of the door at the ?quired height. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $158 $0.00 Record Number 44053 Womens Restroom 105 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.87 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 °aise or replace the lavatory to provide the minimum required Dron height. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $2,500 $0.00 Record Number 44054 Womens Restroom 105 Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 Raise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set rogress Not_Started Assignment Not Set $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 444 of 853 Record Number 44052 Womens Restroom 105 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set $277 $0.00 Record Number 44062 Mens Restroom 104 The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 23.25 inches Code At least 24.00 inches CA 11B-604.5.1 Install or relocate the side grab bar so that the distance from 'ie front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Six .esolution Not Set 'regress Not_Started Assignment Not Set $267 $0.00 Record Number 44063 Mens Restroom 104 The toilet paper dispenser is not mounted at the required height. Finding 17.00 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser in the compartment to the required height. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 445 of 853 Record Number 44064 Mens Restroom 104 The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required (stance from the front edge of the toilet seat. riority Three esolution Not Set rogress Not_Started .ssignment Not Set $78 $0.00 Record Number 44061 Mens Restroom 104 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.37 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 43995 Unisex Restroom 206 The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $804 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 446 of 853 Record Number 43999 Unisex Restroom 206 The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 40.12 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. °riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $300 $0.00 Record Number 44001 Unisex Restroom 206 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three esolution Not Set rogress Not_Started ,assignment Not Set $158 $0.00 Record Number 44000 Unisex Restroom 206 All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 447 of 853 Record Number 43998 Unisex Restroom 206 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set _ rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 43996 Unisex Restroom 206 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 48.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 'elocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Record Number 43997 Unisex Restroom 206 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 448 of 853 Record Number 44014 Unisex Restroom 206 The distance from the back wall to the front of the grab bar is less than required. Finding 52.50 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. priority Three esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 44015 Unisex Restroom 206 The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 22.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $267 $0.00 Record Number 44016 Unisex Restroom 206 The toilet paper dispenser is not mounted at the required height. Finding 16.75 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser in the compartment to the required height. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 449 of 853 Record Number 44017 Unisex Restroom 206 The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required (stance from the front edge of the toilet seat. riority Three .esolution Not Set rogress Not_Started .ssignment Not Set $78 $0.00 Record Number 44011 Unisex Restroom 206 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.25 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 44013 Unisex Restroom 206 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 28.25 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 450 of 853 Record Number 44085 Unisex Restroom There are no grab bars. Finding None Found ADA 4.17.6, ADA 4.16.4, CA 11B-604.5 (stall the required grab bars in the toilet compartment. riority Three esolution Not Set rogress Not_Started Assignment Not Set $267 $0.00 Record Number 44084 Unisex Restroom The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 37.50 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $1,707 $0.00 Record Number 44086 Unisex Restroom The shelf is mounted at an incorrect height. Finding 61.37 inches Code 36.00 - 48.00 inches ADA 4.2.5 ount the shelf at the recommended height. °riority Three esolution Not Set rogress Not_Started Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 451 of 853 Record Number 44093 Unisex Restroom The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 22.00 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. priority Three esolution Not Set 'regress Not_Started Assignment Not Set $277 $0.00 Record Number 44088 Unisex Restroom The height of the toilet seat is not at the required height. Finding 15.62 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. riority Six esolution Not Set 'regress Not_Started .ssignment Not Set $1,707 $0.00 Record Number 44087 Unisex Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 16.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Six esolution Not Set 'regress Not_Started Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 452 of 853 Record Number 44090 Unisex Restroom The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $127 $0.00 Record Number 44091 Unisex Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 29.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Six .esolution Not Set 'rogress Not_Started _,ssignment Not Set $2,500 $0.00 Record Number 44092 Unisex Restroom There is less than the required minimum space in front of the toilet. Finding 46.50 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 'Treate the required minimum clear space in front of the toilet. Priority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 453 of 853 Record Number 44095 Unisex Restroom The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,800 $0.00 Record Number 44094 Unisex Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 rnstall a compliant privacy lock with occupancy indicator to the Dor. riority Six esolution Not Set rogress Not_Started _,ssignment Not Set $804 $0.00 Record Number 44096 Unisex Restroom There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 24.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 Modify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set $14,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 454 of 853 Record Number 44097 Unisex Restroom The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. °riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set $280 $0.00 Record Number 44098 Unisex Restroom The entrance door swings into the turning space within the restroom. Finding 8.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Six .esolution Not Set 'regress Not_Started Assignment Not Set $8,200 $0.00 Record Number 44108 Unisex Restroom The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 50.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 ' ower the mirror so the bottom edge of the reflective surface is u higher than recommended above the finished floor. riority Three .esolution Not Set 'regress Not_Started Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 455 of 853 Record Number 44100 Unisex Restroom Lavatory The faucet controls on the lavatory require tight grasping, pinching, or twisting of the wrist and are not accessible. Finding Not Accessible ADA 4.19.5, ADA 309.4, CA 11B-309.4, CA 11B-213, CA 11B-606 (stall accessible faucet controls on the lavatory. riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set $392 $0.00 Record Number 44107 Unisex Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 44101 Unisex Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 26.62 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required apron height. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 456 of 853 Record Number 44102 Unisex Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.75 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set $1,286 $0.00 Record Number 44103 Unisex Restroom Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 12.25 inches on center Code At least 18.00 inches on center CA 11B-606.6 °eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Six .esolution Not Set rogress Not_Started assignment Not Set $2,500 $0.00 Record Number 44104 Unisex Restroom Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 24.50 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 Relocate the lavatory to provide clear floor space. riority Six .esolution Not Set rogress Not_Started ,ssignment Not Set $2,261 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 457 of 853 Record Number 44105 Unisex Restroom Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 28.00 inches Code At least 48.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 elocate the lavatory to provide clear floor space. riority Six .esolution Not Set 'rogress Not_Started ,ssignment Not Set $2,261 $0.00 Record Number 44106 Unisex Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set $149 $0.00 Record Number 44109 Unisex Restroom All Gender The gender use signage on the entrance door is not mounted at the required height. Finding 66.75 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the . equired height. riority Three esolution Not Set rogress Not_Started ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 458 of 853 Record Number 44110 Unisex Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three esolution Not Set rogress Not_Started _,ssignment Not Set $158 $0.00 Record Number 44099 Unisex Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 52.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Six .esolution Not Set 'rogress Not_Started .ssignment Not Set $277 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44065 Drinking Fountain Near Restrooms The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 "eplace the drinking fountain with a compliant High/Low )untain. Priority Six esolution Not Set rogress Not_Started Assignment Not Set $2,500 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 459 of 853 Record Number 43990 Visual Alarms There are some visual warning devices, though visual warning devices are not located throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, classrooms and eneral use rooms, accessible restrooms and other accessible )oms. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set $2,200 $0.00 Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43923 Kitchen 107 Sink counter height does not meet the standards. Finding 36.00 inches Code Up to 34.00 inches CA 11B-606.3 'rovide compliant sink. riority Seven .esolution Not Set rogress Not_Started ssignment Not Set $1,800 $0.00 Record Number 43924 Kitchen 107 Sink knee clearance does not meet the standards. Finding 22.87 inches Code At least 27.00 inches ADA 4.27 ^rovide compliant sink. riority Seven .esolution Not Set rogress Not_Started ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 460 of 853 Record Number 43925 Kitchen 107 The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain ipes under the sink to protect against contact. Make certain iere are no sharp or abrasive surfaces under the sink. °riority Seven .esolution Not Set rogress Not_Started Assignment Not Set $149 $0.00 Record Number 43926 Kitchen 107 Microwave Appliance Reach Height in the break/conference room is not compliant. Finding 59.50 inches Code Up to 48.00 inches CA 11B-308, CA 11B-309, CA 11B-205 ake sure that the specified appliance reach height is )mpliant. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set $1,200 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43900 2nd Floor Balcony Sink Sink counter height is not compliant. Finding 36.25 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set '1 R00 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 461 of 853 Record Number 43901 2nd Floor Balcony Sink Sink knee clearance does not meet the standards. Finding 23.12 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 rovide compliant sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,800 $0.00 Record Number 43903 2nd Floor Balcony Sink The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Record Number 43902 2nd Floor Balcony Sink There is not enough toe clearance at the sink. Finding 7.75 inches Code At least 9.00 inches ADA 4.27 ovide minimum required toe clearance. °riority Six esolution Not Set rogress Not_Started Assignment Not Set $900 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 462 of 853 Record Number 43920 Classroom 103 Sink counter height is not compliant. Finding 36.25 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set $1,800 $0.00 Record Number 43921 Classroom 103 The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Six esolution Not Set rogress Not_Started Assignment Not Set $420 $0.00 Record Number 43922 Classroom 103 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Two esolution Not Set 'rogress Not_Started Assignment Not Set $149 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 463 of 853 Record Number 43878 1st Floor Rotunda Alarm System - Other The highest point of operation for the element is not compliant. Finding 64.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $50 $0.00 Record Number 43991 Museum Offices Alarm System - Other The highest point of operation for the element is not compliant. Finding 53.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $50 $0.00 Record Number 43992 Museum Offices Donation Box - Other The highest point of operation for the element is not compliant. Finding 57.50 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 464 of 853 Record Number 43993 Museum Offices Electrical Outlets - Electrical Outlet The highest point of operation for the element is not compliant. Finding 11.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $50 $0.00 Record Number 43994 Museum Offices Thermostat - Thermostat The highest point of operation for the element is not compliant. Finding 62.62 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set $50 $0.00 Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43896 Benches In Courtyard The bench height is not compliant. Finding 16.00 inches Code 17.00 - 19.00 inches ADA 5.8, ADA A4.2.6 ^,djust the bench height to recommended value. riority Six .esolution Not Set rogress Not_Started .ssignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 465 of 853 Record Number 43897 Benches In Courtyard The bench length is not compliant. Finding 47.25 inches Code At least 48.00 inches ADA 5.8, ADA A4.2.6 djust the bench length to recommended value. riority Six esolution Not Set rogress Not_Started Assignment Not Set $27 $0.00 Record Number 44029 Benches In Exhibit Halls 200 & 204 The bench length is not compliant. Finding 43.00 inches Code At least 48.00 inches ADA 5.8, ADA A4.2.6 Hdjust the bench length to recommended value. riority Six esolution Not Set rogress Not_Started Assignment Not Set $27 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 466 of 853 La Quinta Senior Center Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43732 Accessible Parking There is no device at the head of the general parking spaces to prevent vehicles from encroaching into walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 )stall a wheel stop at the head of the general parking spaces. riority Four esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $240 $0.00 Record Number 43771 Accessible Parking Parking Lot Warning Sign Signage height from the finished floor is not compliant. Finding 28.00 inches Code At least 36.00 inches CA 11B-502.8 rovide compliant signage at a compliant height. riority Seven esolution Not Set 'rogress Not_Started .assignment Not Set 06/30/2013 $110 $0.00 Record Number 43733 Accessible Parking Left Accessible Space Near Calle La Fonda The accessible parking space does not meet the minimum requirements for width. Finding 107.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Four esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 467 of 853 Record Number 43734 Accessible Parking Left Accessible Space Near Calle La Fonda There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Three esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Record Number 43735 Accessible Parking Left Accessible Space Near Calle La Fonda The surface identification at the designated accessible parking space is not compliant. Finding 48.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43736 Accessible Parking Right Accessible Space Near The South Entrance The slope of the accessible parking space is not compliant. Finding 4.00 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $3,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 468 of 853 Record Number 43738 Accessible Parking Right Accessible Space Near The South Entrance The surface identification at the designated accessible parking space is not compliant. Finding 30.75 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43739 Accessible Parking Right Accessible Space Near The South Entrance The bottom edge of the post -mounted signage designating the accessible parking space is not at the required height. Finding 61.00 inches Code At least 80.00 inches ADA 4.6.4, CA 11B-502.6 °ost signage at a compliant height. Priority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43737 Accessible Parking Right Accessible Space Near The South Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 nroyide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 469 of 853 Record Number 43740 Accessible Parking Center Accessible Space Near The Multi -Purpose Room The accessible parking space does not meet the minimum requirements for width. Finding 106.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43741 Accessible Parking Center Accessible Space Near The Multi -Purpose Room The slope of the accessible parking space is not compliant. Finding 9.40 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 Repave the accessible space to provide a compliant slope. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $3,800 $0.00 Record Number 43742 Accessible Parking Center Accessible Space Near The Multi -Purpose Room The vertical clearance of the accessible parking space is less than required. Finding 90.75 inches Code At least 98.00 inches ADA 4.6.5 rovide sufficient vertical clearance at each accessible parking Jace. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $108 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 470 of 853 Record Number 43743 Accessible Parking Center Accessible Space Near The Multi -Purpose Room There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 stall a wheel stop at the head of the accessible parking space. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43744 Accessible Parking Center Accessible Space Near The Multi -Purpose Room There is no minimum fine sign at the parking space. CA 11B-502.6.2 -'rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. Priority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Record Number 43745 Accessible Parking Center Accessible Space Near The Multi -Purpose Room The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Dace. riority Four esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 471 of 853 Record Number 43746 Accessible Parking Center Accessible Space Near The Multi -Purpose Room The slope of the access aisle is not compliant. Finding 9.00 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the access aisle to provide a compliant surface slope. riority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $3,800 $0.00 Record Number 43751 Accessible Parking Right Accessible Space Near The Multi -Purpose Room The surface identification at the designated accessible parking space is not compliant. Finding 47.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $220 $0.00 Record Number 43747 Accessible Parking Right Accessible Space Near The Multi -Purpose Room The slope of the accessible parking space is not compliant. Finding 14.10 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $3,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 472 of 853 Record Number 43748 Accessible Parking Right Accessible Space Near The Multi -Purpose Room The vertical clearance of the accessible parking space is less than required. Finding 91.00 inches Code At least 98.00 inches ADA 4.6.5 rovide sufficient vertical clearance at each accessible parking Jace. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $108 $0.00 Record Number 43749 Accessible Parking Right Accessible Space Near The Multi -Purpose Room There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 Tnstall a wheel stop at the head of the accessible parking space. tiority Four .esolution Not Set 'rogress Not_Started Asignment Not Set 06/30/2013 $250 $0.00 Record Number 43750 Accessible Parking Right Accessible Space Near The Multi -Purpose Room There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Four esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 473 of 853 Record Number 43752 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The accessible parking space does not meet the minimum requirements for width. Finding 103.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43753 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The vertical clearance of the accessible parking space is less than required. Finding 90.25 inches Code At least 98.00 inches ADA 4.6.5 Provide sufficient vertical clearance at each accessible parking Dace. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $108 $0.00 Record Number 43754 Accessible Parking Left Accessible Space Near The Multi -Purpose Room There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 )stall a wheel stop at the head of the accessible parking space. riority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 474 of 853 Record Number 43756 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The location of the accessible parking spaces requires individuals with disabilities to travel behind parked cars other than their own. Finding See Above CA 11B-502.7 rovide accessible route from the parking space. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43755 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The accessible parking space does not meet the minimum requirement for length. Finding 214.00 inches Code At least 216.00 inches CA 11B-502.2 Re -stripe the accessible parking space. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43757 Accessible Parking Left Accessible Space Near The Multi -Purpose Room There is no minimum fine sign at the parking space. CA 11B-502.6.2 Provide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Three esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 475 of 853 Record Number 43758 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The surface identification at the designated accessible parking space is not compliant. Finding 46.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. tiority Four .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43759 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The bottom edge of the post -mounted signage designating the accessible parking space is not at the required height. Finding 74.25 inches Code At least 80.00 inches ADA 4.6.4, CA 11B-502.6 °ost signage at a compliant height. Priority Four .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43760 Accessible Parking Left Accessible Space Near The Multi -Purpose Room The access aisle does not meet the minimum required width. Finding 93.00 inches Code At least 96.00 inches ADA 4.1.2(5) ^e-stripe the access aisle. tiority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 476 of 853 Record Number 43763 Accessible Parking Right Accessible Space Near Calle La Fonda The surface identification at the designated accessible parking space is not compliant. Finding 48.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Four .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43762 Accessible Parking Right Accessible Space Near Calle La Fonda There is no minimum fine sign at the parking space. CA 11B-502.6.2 °rovide a minimum fine sign at the parking space below the International Symbol of Accessibility. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Record Number 43765 Accessible Parking Left Accessible Space Near The South Entrance The accessible parking space does not meet the minimum requirements for width. Finding 104.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 ^e-stripe the accessible parking space. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 477 of 853 Record Number 43766 Accessible Parking Left Accessible Space Near The South Entrance The slope of the accessible parking space is not compliant. Finding 4.90 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. tiority Four .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $3,800 $0.00 Record Number 43764 Accessible Parking Left Accessible Space Near The South Entrance The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 e-stripe the existing parking space marked as accessible to fine the width of the space. tiority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $350 $0.00 Record Number 43767 Accessible Parking Left Accessible Space Near The South Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 478 of 853 Record Number 43768 Accessible Parking Left Accessible Space Near The South Entrance The surface identification at the designated accessible parking space is not compliant. Finding 30.75 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $220 $0.00 Record Number 43769 Accessible Parking Left Accessible Space Near The South Entrance The slope of the access aisle is not compliant. Finding 4.50 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 °epave the access aisle to provide a compliant surface slope. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $3,800 $0.00 Record Number 43770 Accessible Parking Left Accessible Space Near The South Entrance The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. Finding None Found CA 11B-502.3.3 paint the words "NO PARKING" a compliant height within the :cess aisle. riority Four esolution Not Set 'rogress Not_Started _.ssignment Not Set 06/30/2013 $250 $0.00 Passenger Loading Zones Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 479 of 853 Record Number 43824 Passenger Loading Zone There is no required striped access aisle adjacent to the passenger loading zone. Finding None Found ADA 4.6.6, CA 11B-503.3 tripe a compliant access aisle adjacent and parallel to the =hicle pull-up space. °riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $650 $0.00 Record Number 43825 Passenger Loading Zone There is no signage designating accessibility posted at the passenger loading zone. Finding None Found ADA 4.1.2(7)(b), ADA 4.6.6 Dst compliant signage designating the passenger loading zone 3 accessible. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $400 $0.00 Record Number 43823 Passenger Loading Zone There are no detectable warning devices provided at the passenger loading zone. Finding None Found ADA 4.29.5 (stall detectable warning devices at the passenger loading me. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $144 $0.00 Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 480 of 853 Record Number 43695 Curb Ramp At The Accessible Spaces Near The South Entrance The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Four esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $248 $0.00 Record Number 43696 Curb Ramp At The Accessible Spaces Near The South Entrance The slope of the curb ramp right side flare is greater than allowed. Finding 12.20 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 rovide curb ramp side flares with a compliant slope. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43697 Curb Ramp At The Accessible Spaces Near The South Entrance Bottom Landing The slope at the bottom landing is greater than allowed. Finding 4.50 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.3.2 rovide a compliant bottom landing that does not exceed the iaximum slope requirements. riority Four esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $240 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 481 of 853 Record Number 43698 Curb Ramp At The Accessible Spaces Near The South Entrance Top Landing There is not enough top landing clear length. Finding 36.00 inches Code At least 48.00 inches ADA 4.7, CA 11B-406.5.3 rovide a level top landing with enough clear length. riority Four esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $240 $0.00 Record Number 43815 Curb Ramp At The Accessible Spaces Near The Multi -Purpose Room The curb ramp projects into vehicular traffic lanes, parking spaces, or parking access aisles. Finding Projects ADA 4.7.6, CA 11B-406.5 rovide a compliant curb ramp. riority Four esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $1,400 $0.00 Record Number 43816 Curb Ramp At The Accessible Spaces Near The Multi -Purpose Room The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 Provide compliant detectable warnings to surface. riority Four esolution Not Set rogress Not_Started ssignment Not Set 06/30/2013 $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 482 of 853 Record Number 43817 Curb Ramp At The Accessible Spaces Near The Multi -Purpose Room The surface of the curb ramp does not have a finish that contrasts with the adjacent sidewalk. ADA 4.7.4 rovide the surface on the curb ramp that contrasts with the ijacent sidewalk. tiority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $155 $0.00 Record Number 43818 Curb Ramp At The Accessible Spaces Near The Multi -Purpose Room The running slope is greater than allowed. Finding 9.00 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 Provide a compliant curb ramp. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43819 Curb Ramp At The Accessible Spaces Near The Multi -Purpose Room The slope of the curb ramp right side flare is greater than allowed. Finding 14.10 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 Provide curb ramp side flares with a compliant slope. Priority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 483 of 853 Record Number 43820 Curb Ramp At The Accessible Spaces Near The Multi -Purpose Room Top Landing The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. Finding None Found CA 11B-406.5.11 rovide a compliant grooved border along the top and sides of le curb ramp at the level surface of the sidewalk. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $248 $0.00 Record Number 43850 Curb Ramps Near The Dumpster The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 Provide compliant detectable warnings to surface. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $248 $0.00 Record Number 43851 Curb Ramps Near The Dumpster The running slope is greater than allowed. Finding 9.80 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 rovide a compliant curb ramp. riority Four ,esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 484 of 853 Record Number 43852 Curb Ramps Near The Dumpster The cross slope is greater than allowed. Finding 4.80 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.7 rovide a compliant curb ramp. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,300 $0.00 Record Number 43854 Curb Ramps Near The Dumpster Top Landing The slope at the top landing is greater than allowed. Finding 3.80 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.3 rovide a top landing that has a compliant slope and ianeuvering space. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,260 $0.00 Record Number 43855 Curb Ramps Near The Dumpster Top Landing The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. Finding None Found CA 11B-406.5.11 rovide a compliant grooved border along the top and sides of le curb ramp at the level surface of the sidewalk. Priority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 485 of 853 Record Number 43853 atch the transition area at the bottom of the curb ramp so that le transition is flush and free of abrupt changes. 06/30/2013 $255 $0.00 Curb Ramps Near The Dumpster Bottom Landing The transition from the bottom of the curb ramp to the walk, gutter, or street is abrupt. Finding 0.62 inches Code Up to 0.25 inches ADA 4.5.2, ADA 406.5.8 riority Four .esolution Not Set rogress Not_Started Assignment Not Set Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43792 Path Of Travel Near Passenger Loading Zone Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 9.30 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $3,600 $0.00 Record Number 43826 Path Of Travel From The Accessible Spaces Near Calle La Fonda Crosswalk From The Access Aisle There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 Provide detectable warnings. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 486 of 853 Record Number 43848 Path Of Travel From The Library & The Public Right Of Way Path Of Travel To The Main Entrance There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 rovide detectable warnings. riority Four .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $190 $0.00 Record Number 43849 Path Of Travel From The Library & The Public Right Of Way Path Of Travel To The Main Entrance The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 Provide a compliant crosswalk. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,100 $0.00 Record Number 43847 Path Of Travel From The Library & The Public Right Of Way Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 2.70 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 rovide a compliant path of travel. riority Seven .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 487 of 853 Record Number 43718 ecurely fasten the mats or carpet runners or replace with a iat or carpet runner that grips to the underlying floor surface provide a firm, stable, and slip resistant path of travel. 06/30/2013 $42 $0.00 Path Of Travel In The Lobby Floor Mats The mats or carpet runners do not adhere to the underlying floor surface and slip, thereby creating a hazardous path of travel. Finding Not Accessible ADA 4.5.3, CA 11B-403.2, CA 11B-302 riority Two .esolution Not Set rogress Not_Started ..ssignment Not Set Platform Lifts Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43701 Lift In Multi -purpose Room Platform lift door is not compliant. Finding Not Accessible ADA 4.11, CA 11B-410 ^rovide a compliant platform lift door. riority Six .esolution Not Set 'rogress Not_Started _,ssignment Not Set 06/30/2013 $0.00 Record Number 43699 Lift In Multi -purpose Room There is no International Symbol of Accessibility found at the platform lift. Finding None Found ADA 4.11, CA 11B-410.8 -'rovide a compliant International Symbol of Accessibitliy at the latform lift. riority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $58 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 488 of 853 Record Number 43700 Lift In Multi -purpose Room There is not enough latch side clearance the pull side of the platform lift door. Finding Not Enough Clearance Code At least 18 inches ADA 4.11, CA 11B-404.2.4.1 rovide compliant latch side clearance on the pull side of the latform lift door. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43702 Lift In Multi -purpose Room There is no light in the car. Finding None Found ADA 4.11 rovide a light in the car. riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $800 $0.00 Record Number 43703 Lift In Multi -purpose Room There is not standby power for the car. Finding None Found ADA 4.11, CA 11B-207.2 -ovide standby power for the car. °riority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,100 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 489 of 853 Record Number 43704 Lift In Multi -purpose Room Lift cannot be lowered in case of power loss. Finding None Found ADA 4.11, CA 11B-207.2 ake sure that the lift can be lowered in the event of power Iss. riority Six esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $0.00 Record Number 43705 Lift In Multi -purpose Room Lift device is not red or orange or does not have use instructions. Finding None Found ADA 4.11 ake sure that the lowering device is red or orange and has use istructions. riority Six .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $300 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43874 Stairs To Multi -purpose Room Run 1 The width of the stairway does not meet the minimum required width. Finding 37.62 inches Code At least 44.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 Tnstall a stairway with a minimum width as required. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $4,816 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 490 of 853 Record Number 43875 ffix compliant contrasting striping to the upper approach and 3ch tread that is the correct width and distance from the Dsing. 06/30/2013 $1,000 $0.00 Stairs To Multi -purpose Room Run 1 There is no detectable striping on the stairways. Finding None Found ADA 4.9.5, CA 11B-504.4.1 riority Three .esolution Not Set rogress Not_Started Assignment Not Set Record Number 43876 Stairs To Multi -purpose Room Run 1 Right Handrail The handrail is not mounted at the required height. Finding 32.00 inches Code 34.00 - 38.00 inches ADA 4.9.4(5), CA 11B-504.6, CA 11B-505 °rovide handrail at the required height. riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,528 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43667 Exterior Doors To The Multi -Purpose Room Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 ;25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 491 of 853 Record Number 43791 South Entrance Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43829 Patio Gate Near The Multi -Purpose Room Pull Side There is no level landing at this door. Finding 3.80 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,500 $0.00 Record Number 43828 Patio Gate Near The Multi -Purpose Room Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 2.00 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 Provide the recommended latch side clearance for the door. riority Four .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 492 of 853 Record Number 43827 Patio Gate Near The Multi -Purpose Room Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $400 $0.00 Record Number 43870 Arts & Crafts Room, Lounge, Lobby Exterior Doors The clear opening width of the door is less than required. Finding 30.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 Widen the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $1,750 $0.00 Record Number 43871 Arts & Crafts Room, Lounge, Lobby Exterior Doors Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. tiority Two esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 493 of 853 Record Number 43872 Arts & Crafts Room, Lounge, Lobby Exterior Doors Push / Pull Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Six .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $280 $0.00 Record Number 43651 Interior Doors To The Multi -Purpose Room Push Bar / Lever The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 (stall a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $400 $0.00 Record Number 43652 Interior Doors To The Multi -Purpose Room Push Bar / Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 494 of 853 Record Number 43666 Multi -Purpose Room Kitchen Push Side There is not enough clear floor space provided at the push side of the door . Finding 38.00 inches Code At least 48.00 inches ADA 4.13.6 rovide the recommended clear floor space on the push side of le door. tiority Six .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43665 Multi -Purpose Room Kitchen Lever Has a door stop. Finding Found CA 11B-404.2.10 °emove the door stop. tiority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43674 Exterior Door To Kitchen Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 13.25 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide the recommended latch side clearance for the door. tiority Seven .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 495 of 853 Record Number 43673 Exterior Door To Kitchen The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $436 $0.00 Record Number 43672 Exterior Door To Kitchen Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43671 Exterior Door To Kitchen Lever Door hardware is not mounted at the correct height. Finding 49.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 Mount the door hardware at the recommended height. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 496 of 853 Record Number 43675 Unisex Restroom Near Rear Kitchen Entrance Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 52.75 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the pull side of le door. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43676 Kitchen Rear Entrance Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 12.12 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 °rovide required latch side clearance on the pull side of the Dor. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43678 Mens Restroom Near Main Entrance Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 19.50 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 Provide the recommended latch side clearance for the door. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 497 of 853 Record Number 43677 Mens Restroom Near Main Entrance Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43680 Swinging Door To The Reception Counter Area The clear opening width of the door is less than required. Finding 31.25 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $1,750 $0.00 Record Number 43691 Lounge & Health Room Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 498 of 853 Record Number 43693 Womens Restroom Near The Health Room Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 25.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,921 $0.00 Record Number 43784 Lobby Door Near The Reception Counter Push Bar / D Handle The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Two .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $25 $0.00 Record Number 43785 Lobby Door Near The Reception Counter Push Bar / D Handle Has a door stop. Finding Found CA 11B-404.2.10 ^emove the door stop. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 499 of 853 Record Number 43822 Mens Restroom Near The Lounge Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $25 $0.00 Record Number 43830 Arts & Crafts Room Lever Has a door stop. Finding Found CA 11B-404.2.10 emove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43846 Lobby Doors To The Administrative Offices Lever Has a door stop. Finding Found CA 11B-404.2.10 Remove the door stop. riority Two .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 500 of 853 Record Number 43831 Lobby Service Counter The height of the counter or desk does not comply with height requirements. Finding 34.25 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Seven .esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $3,500 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43690 Patio Door To The Arts & Crafts Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 Tnstall compliant room identification signage. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43653 Office Near Rear Kitchen Entrance The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 59.62 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 "rovide compliant signage identifying the accessible entrance on ie wall adjacent to the latch side of the doorway, mounted at ie required height and location. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 501 of 853 Record Number 43664 Exterior Door To The Kitchen There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Three esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43670 Multi Purpose Room Kitchen The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 59.62 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43694 Administrative Offices There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 Install compliant room identification signage. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 502 of 853 Record Number 43706 Computer Lab The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 60.62 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43821 Lounge The accessible entrance signage attached to the wall is not at the required height above the finished floor. Finding 60.62 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Provide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43645 Unisex Restroom Near Rear Kitchen Entrance The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 42.62 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 Dwer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. riority Seven .esolution Not Set rogress Not_Started ,ssignment Not Set 06/30/2013 $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 503 of 853 Record Number 43646 Unisex Restroom Near Rear Kitchen Entrance All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43642 Unisex Restroom Near Rear Kitchen Entrance Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 17.75 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set .rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43643 Unisex Restroom Near Rear Kitchen Entrance Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 504 of 853 Record Number 43644 Unisex Restroom Near Rear Kitchen Entrance Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43647 Unisex Restroom Near Rear Kitchen Entrance The signage is not mounted at the required height. Finding 60.25 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43648 Unisex Restroom Near Rear Kitchen Entrance There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 )stall signage that includes the International Symbol of ccessibility. tiority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 505 of 853 Record Number 43660 Unisex Restroom Near Rear Kitchen Entrance The height of the side grab bar is not at the correct height. Finding 35.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43661 Unisex Restroom Near Rear Kitchen Entrance The distance from the side wall to the rear grab bar is greater than allowed. Finding 6.50 inches Code Up to 6.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2 emount the rear grab bar at a compliant location. riority Seven esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $78 $0.00 Record Number 43658 Unisex Restroom Near Rear Kitchen Entrance The distance from the back wall to the front of the grab bar is less than required. Finding 49.87 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 506 of 853 Record Number 43659 Unisex Restroom Near Rear Kitchen Entrance The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 18.87 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43662 Unisex Restroom Near Rear Kitchen Entrance The grab bar on the rear wall is not at the correct height. Finding 35.37 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 Remount the rear grab bar in the compartment designated to 2 accessible so the height of the gripping surface is at the )rrect height. tiority Seven .esolution Not Set 'rogress Not_Started _,ssignment Not Set 06/30/2013 $231 $0.00 Record Number 43654 Unisex Restroom Near Rear Kitchen Entrance The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.62 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. tiority Seven .esolution Not Set 'rogress Not_Started .-ssignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 507 of 853 Record Number 43656 Unisex Restroom Near Rear Kitchen Entrance The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 32.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43657 Unisex Restroom Near Rear Kitchen Entrance There is less than the required minimum space in front of the toilet. Finding 47.37 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Seven .esolution Not Set rogress Not_Started ,assignment Not Set 06/30/2013 $3,500 $0.00 Record Number 43663 Unisex Restroom Near Rear Kitchen Entrance The toilet paper dispenser is not mounted at the required height. Finding 18.00 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Three .esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 508 of 853 Record Number 43688 Mens Restroom Near The Lounge The signage is not mounted at the required height. Finding 59.00 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 3st compliant signage at the restroom. riority Seven esolution Not Set rogress Not_Started Assignment Not Set $158 $0.00 Record Number 43689 Mens Restroom Near The Lounge There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. tiority Three esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43687 Mens Restroom Near The Lounge Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 3st gender use signage on the center of the door at the ?quired height. riority Three esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 509 of 853 Record Number 43686 Mens Restroom Near The Lounge Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43713 Mens Restroom In The Lobby The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Provide an accessible handle mounted on the door of the Dmpartment near the latch. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43714 Mens Restroom In The Lobby Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 510 of 853 Record Number 43715 Mens Restroom In The Lobby The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43711 Mens Restroom In The Lobby The height of the side grab bar is not at the correct height. Finding 34.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43709 Mens Restroom In The Lobby The distance from the back wall to the front of the grab bar is less than required. Finding 52.75 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 511 of 853 Record Number 43710 Mens Restroom In The Lobby The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 23.75 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43712 Mens Restroom In The Lobby The grab bar on the rear wall is not at the correct height. Finding 34.50 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 Remount the rear grab bar in the compartment designated to 2 accessible so the height of the gripping surface is at the )rrect height. riority Seven esolution Not Set 'rogress Not_Started _,ssignment Not Set 06/30/2013 $231 $0.00 Record Number 43716 Mens Restroom In The Lobby The toilet paper dispenser is not mounted at the required height. Finding 18.00 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser in the compartment to the required height. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 512 of 853 Record Number 43707 Mens Restroom In The Lobby The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.00 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43724 Administrative Office Unisex Staff Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. tiority Four .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $804 $0.00 Record Number 43725 Administrative Office Unisex Staff Restroom There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 59.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $14,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 513 of 853 Record Number 43731 Administrative Office Unisex Staff Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Three esolution Not Set rogress Not_Started _,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43727 Administrative Office Unisex Staff Restroom Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 9.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Seven .esolution Not Set .rogress Not_Started Assignment Not Set $2,500 $0.00 Record Number 43728 Administrative Office Unisex Staff Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Two .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 514 of 853 Record Number 43729 Administrative Office Unisex Staff Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Two .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $149 $0.00 Record Number 43730 Administrative Office Unisex Staff Restroom All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. tiority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43726 Administrative Office Unisex Staff Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Seven .esolution Not Set 'rogress Not_Started assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 515 of 853 Record Number 43780 Mens Restroom Near The Lounge The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. °riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Record Number 43781 Mens Restroom Near The Lounge The clear opening width of the doorway to the compartment is less than required. Finding 32.50 inches Code At least 34.00 inches ADA 4.13.5, CA 11B-404.2.3, CA 11B-604.8.1.2 liden the doorway to provide a compliant clear opening width hen the door is open 90 degrees. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43782 Mens Restroom Near The Lounge The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Adjust the inside handle so that it is located near the latch. °riority Four .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 516 of 853 Record Number 43778 Mens Restroom Near The Lounge The height of the side grab bar is not at the correct height. Finding 35.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. tiority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43776 Mens Restroom Near The Lounge The distance from the back wall to the front of the grab bar is less than required. Finding 52.50 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43777 Mens Restroom Near The Lounge The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 23.50 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 517 of 853 Record Number 43779 Mens Restroom Near The Lounge The grab bar on the rear wall is not at the correct height. Finding 35.75 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. Priority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Record Number 43774 Mens Restroom Near The Lounge The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $127 $0.00 Record Number 43775 Mens Restroom Near The Lounge The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.62 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. riority Seven esolution Not Set 'rogress Not_Started .-ssignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 518 of 853 Record Number 43772 Mens Restroom Near The Lounge The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.37 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Seven .esolution Not Set 'regress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43783 Mens Restroom Near The Lounge The toilet paper dispenser is not mounted at the required height. Finding 16.50 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Three .esolution Not Set 'regress Not_Started .ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43788 Womens Restroom Near The Health Room Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 519 of 853 Record Number 43789 Womens Restroom Near The Health Room The signage is not mounted at the required height. Finding 59.75 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 3st compliant signage at the restroom. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Record Number 43790 Womens Restroom Near The Health Room There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43787 Womens Restroom Near The Health Room Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.87 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required Dron height. Priority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 520 of 853 Record Number 43786 Womens Restroom Near The Health Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43794 Womens Restroom In The Lobby Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.87 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 Raise or replace the lavatory to provide the minimum required Dron height. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43795 Womens Restroom In The Lobby Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.75 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Seven .esolution Not Set 'rogress Not_Started ..ssignment Not Set 06/30/2013 $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 521 of 853 Record Number 43797 Womens Restroom In The Lobby There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set rogress Not_Started .ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43796 Womens Restroom In The Lobby Female There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43793 Womens Restroom In The Lobby Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Four .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 522 of 853 Record Number 43801 Mens Restroom In The Lobby Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $158 $0.00 Record Number 43800 Mens Restroom In The Lobby Lavatory The height of the counter surface is greater than allowed. Finding 34.12 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $1,286 $0.00 Record Number 43802 Mens Restroom In The Lobby There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 (stall signage that includes the International Symbol of ccessibility. riority Three .esolution Not Set 'rogress Not_Started .,ssignment Not Set 06/30/2013 $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 523 of 853 Record Number 43798 Mens Restroom In The Lobby Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43799 Mens Restroom In The Lobby Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43803 Womens Restroom Near The Health Room There is insufficient clear floor space in the compartment. Finding 59.75 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 Modify or replace the compartment to provide adequate clear Dor space. riority Seven .esolution Not Set 'regress Not_Started .,ssignment Not Set 06/30/2013 $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 524 of 853 Record Number 43812 Womens Restroom Near The Health Room The coat hook is not mounted at the correct height. Finding 63.12 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43810 Womens Restroom Near The Health Room The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 djust the inside handle so that it is located near the latch. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Record Number 43811 Womens Restroom Near The Health Room There is less than the required latch side clearance on the pull side of the door. Finding 12.75 inches Code At least 18.00 inches ADA 4.13.5, CA 11B-604.8.1.2, CA 11B-404 rovide required latch side clearance on the pull side of the Dor. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 525 of 853 Record Number 43808 Womens Restroom Near The Health Room The height of the side grab bar is not at the correct height. Finding 35.62 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43807 Womens Restroom Near The Health Room The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 23.87 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43809 Womens Restroom Near The Health Room The grab bar on the rear wall is not at the correct height. Finding 35.25 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 Remount the rear grab bar in the compartment designated to a accessible so the height of the gripping surface is at the )rrect height. riority Four esolution Not Set 'rogress Not_Started .-ssignment Not Set 06/30/2013 $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 526 of 853 Record Number 43813 Womens Restroom Near The Health Room The toilet paper dispenser is not mounted at the required height. Finding 17.25 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. riority Four esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43814 Womens Restroom Near The Health Room The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 12.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set $277 $0.00 Record Number 43806 Womens Restroom Near The Health Room The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.62 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 527 of 853 Record Number 43804 Womens Restroom Near The Health Room The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43833 Administrative Office Unisex Staff Restroom The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 50.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43832 Administrative Office Unisex Staff Restroom The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Three esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 528 of 853 Record Number 43840 Administrative Office Unisex Staff Restroom The grab bar on the rear wall is not at the correct height. Finding 35.25 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Record Number 43839 Administrative Office Unisex Staff Restroom The height of the side grab bar is not at the correct height. Finding 35.00 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43837 Administrative Office Unisex Staff Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 49.75 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 529 of 853 Record Number 43838 Administrative Office Unisex Staff Restroom The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 20.25 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. tiority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $267 $0.00 Record Number 43835 Administrative Office Unisex Staff Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 27.25 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Six esolution Not Set 'rogress Not_Started _,ssignment Not Set 06/30/2013 $2,500 $0.00 Record Number 43836 Administrative Office Unisex Staff Restroom There is less than the required minimum space in front of the toilet. Finding 42.50 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 'Treate the required minimum clear space in front of the toilet. Priority Six esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 530 of 853 Record Number 43841 Administrative Office Unisex Staff Restroom The toilet paper dispenser is not mounted at the required height. Finding 18.00 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. riority Four esolution Not Set 'regress Not_Started .ssignment Not Set 06/30/2013 $277 $0.00 Record Number 43856 Womens Restroom In The Lobby There is insufficient clear floor space in the compartment. Finding 58.50 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 odify or replace the compartment to provide adequate clear Dor space. riority Seven esolution Not Set 'regress Not_Started .ssignment Not Set 06/30/2013 $4,000 $0.00 Record Number 43862 Womens Restroom In The Lobby The door to the compartment does not have an accessible handle on both sides. Finding Not on both sides. ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 rovide an accessible handle mounted on the door of the )mpartment near the latch. riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 531 of 853 Record Number 43863 Womens Restroom In The Lobby Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. °riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $269 $0.00 Record Number 43864 Womens Restroom In The Lobby The door to the compartment designated to be accessible in the restroom does not have appropriate accessible hardware. Finding Not Accessible ADA 4.13.9, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7, CA 11B-6 04.8.1.2 (stall accessible hardware on the compartment door that does Dt require tight grasping, pinching, or twisting of the wrist. riority Four esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $289 $0.00 Record Number 43865 Womens Restroom In The Lobby The inside handle is not located near the latch. Finding None Found ADA 4.17.5, CA 11B-404.2.7, CA 11B-604.8.1.2 Adjust the inside handle so that it is located near the latch. 'riority Four esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $129 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 532 of 853 Record Number 43860 Womens Restroom In The Lobby The height of the side grab bar is not at the correct height. Finding 34.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $500 $0.00 Record Number 43861 Womens Restroom In The Lobby The grab bar on the rear wall is not at the correct height. Finding 34.25 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $231 $0.00 Record Number 43857 Womens Restroom In The Lobby The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 533 of 853 Record Number 43859 Womens Restroom In The Lobby The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. tiority Six .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $127 $0.00 Record Number 43866 Womens Restroom In The Lobby The toilet paper dispenser is not mounted at the required height. Finding 18.00 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser in the compartment to the iequired height. tiority Seven .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $277 $0.00 Record Number 43867 Womens Restroom In The Lobby The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 12.75 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 Remount the toilet paper dispenser at a compliant height and location. tiority Seven .esolution Not Set 'rogress Not_Started .-ssignment Not Set 06/30/2013 $277 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 534 of 853 Record Number 43873 Drinking Fountain In The Lobby The spout outlet height is greater than required. Finding 37.50 inches Code Up to 36.00 inches ADA 4.15.2, CA 11B-602.4 rovide a spout outlet that does not exceed the required height. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $627 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43679 Visual Alarms There are visual warning devices provided throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 Since visual warning devices are provided in all areas of the icility, no additional action is required. Priority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $0.00 Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43720 Staff Lounge Sink knee clearance does not meet the standards. Finding 26.75 inches Code At least 27.00 inches ADA 4.27 rovide compliant sink. riority Seven .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 535 of 853 Record Number 43721 Staff Lounge The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain Ipes under the sink to protect against contact. Make certain iere are no sharp or abrasive surfaces under the sink. °riority Two esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $149 $0.00 Record Number 43722 Staff Lounge Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Four esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $110 $0.00 Record Number 43719 Staff Lounge There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 Install an International Symbol of Accessibility at the table. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $158 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 536 of 853 Record Number 43649 Kitchen There is not enough clear floor space at the sink. Finding 23.00 inches Code At least 30.00 inches ADA 4.27 rovide enough clear floor space at the location. riority Seven esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $900 $0.00 Record Number 43650 Kitchen Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 40.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Seven esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43668 Office Near Rear Kitchen Entrance Twist controls are present on the sink. Finding Needs Twisting ADA 4.27 Provide compliant controls for the sink. °riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $392 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 537 of 853 Record Number 43669 Office Near Rear Kitchen Entrance Sink counter height is not compliant. Finding 34.12 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Seven esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $1,800 $0.00 Record Number 43681 Arts & Crafts The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $420 $0.00 Record Number 43682 Arts & Crafts The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. °riority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 538 of 853 Record Number 43683 Arts & Crafts There is not enough clear floor space at the sink. Finding 28.50 inches Code At least 30.00 inches ADA 4.27 ,ovide enough clear floor space at the location. tiority Four esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $900 $0.00 Record Number 43684 Arts & Crafts Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Three .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43685 Arts & Crafts Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 46.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Three .esolution Not Set 'rogress Not_Started _assignment Not Set 06/30/2013 $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 539 of 853 Record Number 43868 Sink Near The Health Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Record Number 43869 Sink Near The Health Room Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Four .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $180 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43717 Patio Picnic Tables The required percentage of picnic tables provided are not accessible. Finding None Found Code At least 1.00 tables ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 "rovide a sufficient number of compliant picnic tables. riority Three .esolution Not Set 'regress Not_Started ,ssignment Not Set 06/30/2013 $500 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 540 of 853 Record Number 43692 First Aid Kit In The Administrative Office Unisex Staff Restroom First Aid Kit - Other The highest point of operation for the element is not compliant. Finding 64.50 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set 'rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43723 Phones In The Lounge, Arts & Crafts Room Phone - Other The highest point of operation for the element is not compliant. Finding 58.62 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 "lake sure that the highest point of operation is within the ?commended value. riority Three .esolution Not Set rogress Not_Started Assignment Not Set 06/30/2013 $50 $0.00 Record Number 43842 Computer Lab Computer Station - Computer Station The clear floor space width is not compliant. Finding 27.50 inches Code At least 30.00 inches ADA 4.2, CA 11B-305 'rovide compliant clear floor space. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 541 of 853 Record Number 43843 djust knee height to the recommended value. 06/30/2013 $500 $0.00 Computer Lab Computer Station - Computer Station The knee height is not compliant. Finding 24.75 inches Code At least 27.00 inches ADA 4.2 riority Seven .esolution Not Set rogress Not_Started assignment Not Set Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 43844 Benches Near The Main Entrance The bench height is not compliant. Finding 16.25 inches Code 17.00 - 19.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench height to recommended value. riority Seven .esolution Not Set 'rogress Not_Started ,ssignment Not Set 06/30/2013 $800 $0.00 Record Number 43845 Benches Near The Main Entrance The bench length is not compliant. Finding 43.50 inches Code At least 48.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench length to recommended value. riority Seven .esolution Not Set 'rogress Not_Started .ssignment Not Set 06/30/2013 $27 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 542 of 853 La Quinta YMCA Daycare Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30904 Accessible Parking The minimum number of accessible parking spaces are not provided in the parking lot. Finding 2.00 spaces Code At least 3.00 spaces ADA 4.1.2(5), CA 11B-208.2 e-stripe any existing parking spaces marked accessible and -eate additional accessible parking spaces. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $370 $0.00 Record Number 30905 Accessible Parking There is no designated "van accessible" parking space provided in the parking lot. Finding None Found ADA 4.1.2(5), CA 11B-208.2.4, CA 11B-502.7 rovide a compliant van accessible space. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $370 $0.00 Record Number 30906 Accessible Parking There is no device at the head of the general parking spaces to prevent vehicles from encroaching into walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 )stall a wheel stop at the head of the general parking spaces. riority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set 240 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 543 of 853 Record Number 30924 Accessible Parking Parking Lot Warning Sign The point of contact and telephone number for reclaiming towed vehicles have been left blank. Finding Sign not Filled CA 11B-502.8.2 II in the blank spaces with the point of contact and telephone umber for reclaiming towed vehicles. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 30911 Accessible Parking Right Accessible Space The slope of the access aisle is not compliant. Finding 14.60 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 °epave the access aisle to provide a compliant surface slope. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $3,800 $0.00 Record Number 30914 Accessible Parking Right Accessible Space The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. Finding None Found CA 11B-502.3.3 paint the words "NO PARKING" a compliant height within the :cess aisle. tiority Not Set .esolution Not Set 'rogress Not Set _.ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 544 of 853 Record Number 30912 Accessible Parking Right Accessible Space The access aisle markings are faded, damaged, or otherwise not viewable. Finding None Found CA 11B-502.3 e-stripe the access aisle so as to discourage parking. tiority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $250 $0.00 Record Number 30913 Accessible Parking Right Accessible Space The hatched lines are striped a noncompliant distance on center. Finding Not on 36" center CA 11B-502.3.3 Re -stripe the hatched lines in a contrasting color at a compliant 'istance on center. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $350 $0.00 Record Number 30910 Accessible Parking Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 52.50 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 545 of 853 Record Number 30908 Accessible Parking Right Accessible Space The slope of the accessible parking space is not compliant. Finding 2.70 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $3,800 $0.00 Record Number 30907 Accessible Parking Right Accessible Space The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 e-stripe the existing parking space marked as accessible to fine the width of the space. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $350 $0.00 Record Number 30909 Accessible Parking Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 546 of 853 Record Number 30915 Accessible Parking Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 98.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $350 $0.00 Record Number 30916 Accessible Parking Left Accessible Space The slope of the accessible parking space is not compliant. Finding 2.80 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 Repave the accessible space to provide a compliant slope. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $3,800 $0.00 Record Number 30917 Accessible Parking Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. 'riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 547 of 853 Record Number 30919 Accessible Parking Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 52.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. tiority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $220 $0.00 Record Number 30918 Accessible Parking Left Accessible Space ISA surface identification is faded and not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.6.4 °epaint the ISA surface identification in the parking space. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $117 $0.00 Record Number 30920 Accessible Parking Left Accessible Space The slope of the access aisle is not compliant. Finding 10.10 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 ^epave the access aisle to provide a compliant surface slope. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $3,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 548 of 853 Record Number 30923 Accessible Parking Left Accessible Space The access aisle does not contain the wording "No Parking" painted in white letters within the access aisle. Finding None Found CA 11B-502.3.3 aint the words "NO PARKING" a compliant height within the :cess aisle. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 30921 Accessible Parking Left Accessible Space The access aisle markings are faded, damaged, or otherwise not viewable. Finding None Found CA 11B-502.3 De -stripe the access aisle so as to discourage parking. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 30922 Accessible Parking Left Accessible Space The hatched lines are striped a noncompliant distance on center. Finding Not on 36" center CA 11B-502.3.3 'e-stripe the hatched lines in a contrasting color at a compliant stance on center. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $350 $0.00 Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 549 of 853 Record Number 31244 Curb Ramp At The Right Access Aisle The curb ramp projects into vehicular traffic lanes, parking spaces, or parking access aisles. Finding Projects ADA 4.7.6, CA 11B-406.5 rovide a compliant curb ramp. riority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $1,400 $0.00 Record Number 31245 Curb Ramp At The Right Access Aisle The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set ,assignment Not Set $248 $0.00 Record Number 31246 Curb Ramp At The Right Access Aisle The running slope is greater than allowed. Finding 14.60 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 Provide a compliant curb ramp. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 550 of 853 Record Number 31247 Curb Ramp At The Right Access Aisle Top Landing The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. Finding None Found CA 11B-406.5.11 rovide a compliant grooved border along the top and sides of le curb ramp at the level surface of the sidewalk. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $248 $0.00 Record Number 31248 Curb Ramp At The Left Access Aisle The curb ramp projects into vehicular traffic lanes, parking spaces, or parking access aisles. Finding Projects ADA 4.7.6, CA 11B-406.5 °rovide a compliant curb ramp. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,400 $0.00 Record Number 31249 Curb Ramp At The Left Access Aisle The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 'rovide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 551 of 853 Record Number 31250 Curb Ramp At The Left Access Aisle The running slope is greater than allowed. Finding 10.20 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 rovide a compliant curb ramp. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,300 $0.00 Record Number 31251 Curb Ramp At The Left Access Aisle Top Landing The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. Finding None Found CA 11B-406.5.11 rovide a compliant grooved border along the top and sides of le curb ramp at the level surface of the sidewalk. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $248 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30978 Path Of Travel From The Public Right Of Way Crosswalk From The Public Right Of Way There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 rovide detectable warnings. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $19G $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 552 of 853 Record Number 30979 Path Of Travel From The Public Right Of Way Crosswalk From The Public Right Of Way The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 rovide a compliant crosswalk. tiority Not Set .esolution Not Set rogress Not Set assignment Not Set $1,100 $0.00 Record Number 31090 Path Of Travel From The Right Accessible Space To The Main Entrance Concrete Upheavel There is a change in elevation greater than recommended value. Finding 1.00 inches Code Up to 0.25 inches ADA 4.3.8, CA 11B-303, CA 11B-403.4 nsure that the change in elevation is within the recommended Slue. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $150 $0.00 Record Number 31088 Path Of Travel From The Right Accessible Space To The Main Entrance Open Area There are slopes greater than allowed maximum slope on the primary path of travel. Finding 6.20 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 553 of 853 Record Number 31089 Path Of Travel From The Right Accessible Space To The Main Entrance Open Area There are cross slopes greater than allowed on the primary path of travel. Finding 3.20 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 rovide a compliant path of travel. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $3,600 $0.00 Record Number 31217 Path Of Travel From The Left Accessible Spaces To Classroom 1 Exterior Entrance Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 19.20 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 -'rovide a compliant path of travel. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $3,600 $0.00 Record Number 31218 Path Of Travel From The Left Accessible Spaces To Classroom 1 Exterior Entrance Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 5.40 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 provide a compliant path of travel. riority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $3,600 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 554 of 853 Record Number 30845 Main Entrance The door closing device limits the required headroom clearance. Finding 78.00 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 30847 Main Entrance Lever Door hardware is not mounted at the correct height. Finding 45.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 ount the door hardware at the recommended height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $280 $0.00 Record Number 30860 Unisex Staff Restroom Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 14.00 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 555 of 853 Record Number 30859 Unisex Staff Restroom Lever The door opening force for this door is greater than allowed. Finding 12.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 30933 South Exterior Door To School Age Room 2 The door closing device limits the required headroom clearance. Finding 77.50 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 30935 South Exterior Door To School Age Room 2 Pull Side There is no level landing at this door. Finding 4.20 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 556 of 853 Record Number 30937 North Unisex Restroom In School Age Room 2 The clear opening width of the door is less than required. Finding 28.00 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 30939 North Unisex Restroom In School Age Room 2 Push Side There is not enough clear floor space provided at the push side of the door . Finding 45.50 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,000 $0.00 Record Number 30940 North Unisex Restroom In School Age Room 2 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 41.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 557 of 853 Record Number 30980 Girls Restroom In Kindergarten Room The clear opening width of the door is less than required. Finding 27.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 30982 Girls Restroom In Kindergarten Room Push Side There is not enough clear floor space provided at the push side of the door . Finding 30.00 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,000 $0.00 Record Number 30983 Girls Restroom In Kindergarten Room Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 39.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 558 of 853 Record Number 30984 Exterior Entrance To Pre -School Room 2 The door closing device limits the required headroom clearance. Finding 77.75 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 30986 Exterior Entrance To Pre -School Room 2 Pull Side There is no level landing at this door. Finding 7.10 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 30988 Unisex Restroom In School Age Room 2 The door closing device limits the required headroom clearance. Finding 78.50 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 559 of 853 Record Number 30990 Unisex Restroom In School Age Room 2 Push Side There is less than the required latch side clearance on the push side of the door. Finding 4.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 30991 Unisex Restroom In School Age Room 2 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 47.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 °rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,921 $0.00 Record Number 31028 Classroom 1 The door closing device limits the required headroom clearance. Finding 79.00 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 Replace the door closing device with a device that fits above the 'Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 560 of 853 Record Number 31030 Classroom 1 Push Side There is less than the required latch side clearance on the push side of the door. Finding 4.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 31051 Exterior Entrance From The Pre-school Room 3 To The Play Area The door closing device limits the required headroom clearance. Finding 77.50 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 °eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $250 $0.00 Record Number 31052 Exterior Entrance From The Pre-school Room 3 To The Play Area The clear opening width of the door is less than required. Finding 27.25 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 '^liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 561 of 853 Record Number 31056 Exterior Entrance From The Pre-school Room 3 To The Play Area Push Side There is less than the required latch side clearance on the push side of the door. Finding 3.00 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 31057 Exterior Entrance From The Pre-school Room 3 To The Play Area Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 47.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 31058 Exterior Entrance From The Pre-school Room 3 To The Play Area Pull Side There is no level landing at this door. Finding 2.90 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 provide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 562 of 853 Record Number 31054 Exterior Entrance From The Pre-school Room 3 To The Play Area Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $25 $0.00 Record Number 31055 Exterior Entrance From The Pre-school Room 3 To The Play Area Lever Door hardware is not mounted at the correct height. Finding 44.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 "fount the door hardware at the recommended height. Priority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $280 $0.00 Record Number 31059 Girls Restroom In The Pre -School Room 3 The clear opening width of the door is less than required. Finding 27.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 '^liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 563 of 853 Record Number 31060 Girls Restroom In The Pre -School Room 3 Push Side There is not enough clear floor space provided at the push side of the door . Finding 33.50 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 31061 Girls Restroom In The Pre -School Room 3 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 43.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 °rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,921 $0.00 Record Number 31068 North Exterior Entrance To School Age Room 2 The door closing device limits the required headroom clearance. Finding 77.50 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 Replace the door closing device with a device that fits above the 'Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 564 of 853 Record Number 31070 North Exterior Entrance To School Age Room 2 Pull Side There is no level landing at this door. Finding 3.80 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. tiority Not Set .esolution Not Set 'regress Not Set assignment Not Set $1,500 $0.00 Record Number 31071 Door From The Kindergarten Room To The Courtyard The door closing device limits the required headroom clearance. Finding 77.25 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. tiority Not Set .esolution Not Set 'regress Not Set .ssignment Not Set $250 $0.00 Record Number 31073 Door From The Kindergarten Room To The Courtyard Pull Side There is no level landing at this door. Finding 6.90 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. tiority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 565 of 853 Record Number 31079 Laundry Room Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 41.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 31078 Laundry Room The height of the threshold at the entrance door is greater than allowed. Finding 5.50 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "lodify or replace the threshold to provide the recommended eight. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $436 $0.00 Record Number 31077 Laundry Room Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 566 of 853 Record Number 31091 Unisex Restroom In Classroom 1 The vertical clearance height of the open doorway is not compliant. Finding 79.00 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. tiority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $5,600 $0.00 Record Number 31126 Exterior Entrance To Kindergarten Room The door closing device limits the required headroom clearance. Finding 78.25 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. tiority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 31129 Exterior Entrance To Kindergarten Room Pull Side There is no level landing at this door. Finding 2.30 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 567 of 853 Record Number 31128 Exterior Entrance To Kindergarten Room Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 31147 School Age Room 1 Exterior Entranceway The door closing device limits the required headroom clearance. Finding 77.00 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 31149 School Age Room 1 Exterior Entranceway Pull Side There is no level landing at this door. Finding 4.70 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 568 of 853 Record Number 31150 Classroom 2 The door closing device limits the required headroom clearance. Finding 78.25 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 31152 Classroom 2 Push Side There is less than the required latch side clearance on the push side of the door. Finding 4.50 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 31160 Door From The Pre -School Room 3 To The Restrooms The clear opening width of the door is less than required. Finding 27.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 /iden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 569 of 853 Record Number 31162 Door From The Pre -School Room 3 To The Restrooms Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 2.50 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 31163 Door From The Pre -School Room 3 To The Restrooms Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 57.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 °rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,921 $0.00 Record Number 31165 Unisex Restroom In Classroom 2 The vertical clearance height of the open doorway is not compliant. Finding 79.50 inches Code At least 80.00 inches ADA 4.13.5 Provide a compliant open doorway at the location. riority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $5,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 570 of 853 Record Number 31175 Exterior Entrance From Pre -School Room 3 To The Courtyard The door closing device limits the required headroom clearance. Finding 77.50 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 31178 Exterior Entrance From Pre -School Room 3 To The Courtyard Pull Side There is no level landing at this door. Finding 5.20 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 31177 Exterior Entrance From Pre -School Room 3 To The Courtyard Lever Door hardware is not mounted at the correct height. Finding 44.50 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 Mount the door hardware at the recommended height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 571 of 853 Record Number 31215 Door From School Age Room 2 To Unisex Restrooms Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 5.00 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 31216 School Age Room 1 The vertical clearance height of the door is less than required. Finding 70.00 inches Code At least 78.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 Extend the height of the doorway to provide the required earance height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,000 $0.00 Record Number 31220 Boys Restroom In the Kindergarten Room The clear opening width of the door is less than required. Finding 27.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 'Viden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 572 of 853 Record Number 31222 Boys Restroom In the Kindergarten Room Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 39.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 31232 South Unisex Restroom In School Age Room 2 The clear opening width of the door is less than required. Finding 27.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 Widen the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,750 $0.00 Record Number 31234 South Unisex Restroom In School Age Room 2 Push Side There is not enough clear floor space provided at the push side of the door . Finding 45.50 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide the recommended clear floor space on the push side of le door. tiority Not Set esolution Not Set 'rogress Not Set _.ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 573 of 853 Record Number 31235 South Unisex Restroom In School Age Room 2 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 41.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 31236 Boys Restroom In The Pre -School Room 3 The clear opening width of the door is less than required. Finding 27.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 Widen the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,750 $0.00 Record Number 31238 Boys Restroom In The Pre -School Room 3 Push Side There is not enough clear floor space provided at the push side of the door . Finding 33.50 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 provide the recommended clear floor space on the push side of le door. tiority Not Set .esolution Not Set 'rogress Not Set _.ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 574 of 853 Record Number 31239 rovide the recommended clear floor space on the pull side of le door. $2,921 $0.00 Boys Restroom In The Pre -School Room 3 Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 39.75 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30815 Reception Counter In The Lobby The height of the counter or desk does not comply with height requirements. Finding 42.25 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Not Set esolution Not Set 'rogress Not Set _,ssignment Not Set $3,500 $0.00 Record Number 30834 Counter In Kitchen The height of the counter or desk used primarily by children is not within compliant height ranges for the primary age group. Finding 36.00 inches Code 26.00 - 30.00 inches ADA 4.32.5(3), ADA 7.2, CA 11B-902.4.2 ake sure a portion of the counter is within compliant height inges to accommodate age group requirements for children. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $545 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 575 of 853 Record Number 30864 Main Entrance To The YMCA Daycare Center There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 )stall accessible room signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 31118 Directional Signage From The Accessible Parking To The Main Entrance There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 Install directional signage to each accessible element or room. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 30836 Main Entrance To YMCA Daycare Center There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 Tnstall accessible room signage. riority Not Set esolution Not Set rogress Not Set ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 576 of 853 Record Number 30848 Copy Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 30849 Administrative Reception Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 30861 Directors Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 577 of 853 Record Number 30862 CVHC Administrative Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 30863 Kitchen There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 30903 Exterior Entrance To Pre -School Room 2 There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 578 of 853 Record Number 30936 Classroom 2 There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 lstall accessible room signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 30972 Exterior Entrance From Pre-school Room 3 To Play Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 30987 Classroom 1 There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 579 of 853 Record Number 30992 Door From Pre -School Room 3 To Restrooms There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 31050 School Age Room 1 Exterior Entranceway There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 31074 South Exterior Door To School Age Room 2 There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 580 of 853 Record Number 31075 Exterior Entrance To Kindergarten Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 31080 School Age Room 2 Exterior Entrance There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 31081 Door From School Age Room 2 To Childrens Unisex Restrooms There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 581 of 853 Record Number 31164 Exterior Entrance From Pre -School Room 3 To The Foye There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 31166 Conference Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 31200 Door From Kindergarten To The Foyer There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 582 of 853 Record Number 31201 School Age Room 1 There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 31219 Laundry Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30818 Unisex Staff Restroom The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 modify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set esolution Not Set rogress Not Set ,ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 583 of 853 Record Number 30816 Unisex Staff Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $804 $0.00 Record Number 30819 Unisex Staff Restroom There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 58.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 30820 Unisex Staff Restroom The entrance door swings into the turning space within the restroom. Finding 15.50 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $8,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 584 of 853 Record Number 30828 Unisex Staff Restroom The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 42.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $300 $0.00 Record Number 30829 Unisex Staff Restroom The top of the mirror is not at the compliant height. Finding 71.75 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $250 $0.00 Record Number 30831 Unisex Staff Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 585 of 853 Record Number 30823 Unisex Staff Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.00 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required iron height. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30824 Unisex Staff Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 24.50 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,286 $0.00 Record Number 30825 Unisex Staff Restroom Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 13.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 Replace or remount lavatory to meet the minimum required 'lstance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set esolution Not Set .rogress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 586 of 853 Record Number 30826 Unisex Staff Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 30827 Unisex Staff Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 30830 Unisex Staff Restroom All Gender The gender use signage on the entrance door is not mounted at the required height. Finding 63.00 inches Code 60.00 inches CA 11B-703.7.2.6 post gender use signage on the center of the door at the required height. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 587 of 853 Record Number 30821 Unisex Staff Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 48.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $277 $0.00 Record Number 30822 Unisex Staff Restroom Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.40 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $277 $0.00 Record Number 30852 Unisex Staff Restroom The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 59.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. tiority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 588 of 853 Record Number 30853 Unisex Staff Restroom There are no grab bars. Finding None Found ADA 4.17.6, ADA 4.16.4, CA 11B-604.5 (stall the required grab bars in the toilet compartment. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $267 $0.00 Record Number 30851 Unisex Staff Restroom The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Record Number 30854 Unisex Staff Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 589 of 853 Record Number 30856 Unisex Staff Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 33.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30857 Unisex Staff Restroom There is less than the required minimum space in front of the toilet. Finding 42.25 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $3,500 $0.00 Record Number 30873 Unisex Restroom In Room 1 There is insufficient clear floor space in the compartment. Finding 59.00 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 odify or replace the compartment to provide adequate clear Dor space. tiority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 590 of 853 Record Number 30875 Unisex Restroom In Room 1 There is no door on the compartment designated to be accessible in the restroom. Finding None Found ADA 4.17.5, CA 11B-604.8.1, CA 11B-604.8 (stall a door with appropriate accessible door hardware on the )mpartment designated to be accessible in the restroom. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 30874 Unisex Restroom In Room 1 Path of travel width to the accessible compartment is not compliant. Finding 40.75 inches Code At least 44.00 inches ADA A4.17.3, CA 11B-604.8.1.2 ake sure that the path of travel width to the accessible )mpartment is compliant. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,400 $0.00 Record Number 30879 Unisex Restroom In Room 1 The height of the side grab bar is not at a compliant height for the primary age group. Finding 33.25 inches Code 20.00 - 22.00 inches ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.9 emount the side grab bar in the compartment designated to e accessible in the restroom at to the required height for use y the primary age group. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $78 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 591 of 853 Record Number 30880 Unisex Restroom In Room 1 The grab bar on the rear wall is not at the correct height. Finding 33.00 inches Code 20.00 - 22.00 inches ADA 4.16.7(3), CA 11B-604.9 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Record Number 30878 Unisex Restroom In Room 1 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 39.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30876 Unisex Restroom In Room 1 The distance from the center line of the toilet to the nearest side wall is not compliant for the primary age group. Finding 20.00 inches on center Code 12.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance )r the primary age group. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 592 of 853 Record Number 30881 Unisex Restroom In Room 1 The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $804 $0.00 Record Number 30888 Unisex Restroom In Room 1 The bottom edge of the reflective surface of the mirror in the restroom is not at a compliant height for the primary age group. Finding 33.25 inches Code Up to 32.00 inches ADA 4.19.6, CA 11B-603.3, CA 11B-604.9 Dwer the mirror in the restroom so that the bottom edge of the ?flective surface is no higher than recommended above the nish floor. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $291 $0.00 Record Number 30889 Unisex Restroom In Room 1 All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 post gender use signage on the center of the door at the required height. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 593 of 853 Record Number 30886 Unisex Restroom In Room 1 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 30887 Unisex Restroom In Room 1 Lavatory There is not enough toe clearance at the restroom lavatory. Finding 6.00 inches Code At least 9.00 inches ADA 4.19.2 Provide minimum required toe clearance. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $289 $0.00 Record Number 30883 Unisex Restroom In Room 1 Lavatory The lavatory is in an enclosed cabinet, thereby preventing an accessible forward approach. Finding Not Accessible ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306 emove or modify the lavatory cabinet and provide a compliant vatory. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $420 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 594 of 853 Record Number 30884 Unisex Restroom In Room 1 Lavatory The knee clearance space under the lavatory designated to be accessible in the restroom is less than the required minimum for the primary age group. Finding 18.00 inches Code At least 19.00 inches ADA 4.19.2, CA 11B-604.9 einstall or replace the lavatory designated to be accessible ith an accessible lavatory that provides the required knee earance for the primary age group. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 30885 Unisex Restroom In Room 1 Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 27.00 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 elocate the lavatory to provide clear floor space. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,261 $0.00 Record Number 30890 Unisex Restroom In Room 1 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. tiority Not Set .esolution Not Set 'rogress Not Set ,.ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 595 of 853 Record Number 30882 Unisex Restroom In Room 1 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 eplace dispenser with one that allows operation with one hand ld does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 30891 Girls Restroom In The Pre -School Room 3 The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,800 $0.00 Record Number 30892 Girls Restroom In The Pre -School Room 3 There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 34.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $14,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 596 of 853 Record Number 30893 Girls Restroom In The Pre -School Room 3 The entrance door swings into the turning space within the restroom. Finding 13.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $8,200 $0.00 Record Number 30897 Girls Restroom In The Pre -School Room 3 Lavatory The height of the counter surface of the lavatory designated to be accessible in the restroom is greater than the allowed maximum height for the primary age group. Finding 30.00 inches Code Up to 24.00 inches ADA 4.19.2, CA 11B-604.9 Raise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 30898 Girls Restroom In The Pre -School Room 3 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 12.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. 'riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 597 of 853 Record Number 30899 Girls Restroom In The Pre -School Room 3 Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 30900 Girls Restroom In The Pre -School Room 3 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 30901 Girls Restroom In The Pre -School Room 3 Female The gender use signage on the entrance door is not mounted at the required height. Finding 67.00 inches Code 60.00 inches CA 11B-703.7.2.6 Post gender use signage on the center of the door at the required height. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 598 of 853 Record Number 30902 Girls Restroom In The Pre -School Room 3 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Record Number 30894 Girls Restroom In The Pre -School Room 3 Paper Towel The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 32.50 inches Code Up to 32.00 inches ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 elocate the dispenser in the restroom to meet the required eight for the primary age group. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 30895 Girls Restroom In The Pre -School Room 3 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 eplace dispenser with one that allows operation with one hand ld does not require tight grasping, pinching, or twisting of the rist. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 599 of 853 Record Number 30896 Girls Restroom In The Pre -School Room 3 Soap The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 39.00 inches Code Up to 32.00 inches ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 elocate the dispenser in the restroom to meet the required eight for the primary age group. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 30941 Unisex Restroom In School Age Room 2 The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 )stall a compliant privacy lock with occupancy indicator to the eor. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $804 $0.00 Record Number 30950 Unisex Restroom In School Age Room 2 The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 42.50 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 Dwer the mirror so the bottom edge of the reflective surface is 10 higher than recommended above the finished floor. riority Not Set .esolution Not Set 'rogress Not Set ssignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 600 of 853 Record Number 30951 Unisex Restroom In School Age Room 2 The top of the mirror is not at the compliant height. Finding 71.75 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $250 $0.00 Record Number 30945 Unisex Restroom In School Age Room 2 Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.50 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required Dron height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,500 $0.00 Record Number 30946 Unisex Restroom In School Age Room 2 Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 25.00 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 601 of 853 Record Number 30947 Unisex Restroom In School Age Room 2 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 13.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set .esolution Not Set .:rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30948 Unisex Restroom In School Age Room 2 Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. riority Not Set .esolution Not Set rogress Not Set ssignment Not Set $149 $0.00 Record Number 30949 Unisex Restroom In School Age Room 2 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 602 of 853 Record Number 30953 Unisex Restroom In School Age Room 2 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Record Number 30952 Unisex Restroom In School Age Room 2 All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Record Number 30942 Unisex Restroom In School Age Room 2 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 603 of 853 Record Number 30943 Unisex Restroom In School Age Room 2 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 48.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 30944 Unisex Restroom In School Age Room 2 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 Replace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 30954 Boys Restroom In The Pre -School Room 3 The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 604 of 853 Record Number 30955 Boys Restroom In The Pre -School Room 3 There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 42.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 30956 Boys Restroom In The Pre -School Room 3 The entrance door swings into the turning space within the restroom. Finding 9.50 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $8,200 $0.00 Record Number 30965 Boys Restroom In The Pre -School Room 3 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. 'riority Not Set esolution Not Set 'rogress Not Set ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 605 of 853 Record Number 30960 Boys Restroom In The Pre -School Room 3 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 14.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set .esolution Not Set _ rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30961 Boys Restroom In The Pre -School Room 3 Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 47.75 inches Code At least 48.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 'elocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,261 $0.00 Record Number 30962 Boys Restroom In The Pre -School Room 3 Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 606 of 853 Record Number 30963 Boys Restroom In The Pre -School Room 3 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 30959 Boys Restroom In The Pre -School Room 3 Lavatory The height of the counter surface of the lavatory designated to be accessible in the restroom is greater than the allowed maximum height for the primary age group. Finding 29.50 inches Code Up to 24.00 inches ADA 4.19.2, CA 11B-604.9 aise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,286 $0.00 Record Number 30964 Boys Restroom In The Pre -School Room 3 Male The gender use signage on the entrance door is not mounted at the required height. Finding 66.50 inches Code 60.00 inches CA 11B-703.7.2.6 post gender use signage on the center of the door at the required height. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 607 of 853 Record Number 30957 Boys Restroom In The Pre -School Room 3 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 eplace dispenser with one that allows operation with one hand -id does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 30958 Boys Restroom In The Pre -School Room 3 Soap The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 39.50 inches Code Up to 32.00 inches ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 elocate the dispenser in the restroom to meet the required eight for the primary age group. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Record Number 30967 Girls Restroom In Pre -School Room 3 There are grab bars missing from the toilet compartment. Finding None Found ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3 Install the required compliant grab bars in the toilet compartment. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 608 of 853 Record Number 30966 Girls Restroom In Pre -School Room 3 The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 58.00 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 30970 Girls Restroom In Pre -School Room 3 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 18.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30971 Girls Restroom In Pre -School Room 3 There is less than the required minimum space in front of the toilet. Finding 33.50 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 609 of 853 Record Number 30968 Girls Restroom In Pre -School Room 3 The distance from the center line of the toilet to the nearest side wall is not compliant for the primary age group. Finding 18.00 inches on center Code 12.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance r the primary age group. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 30994 South Unisex Restroom In School Age Room 2 The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 Modify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 30995 South Unisex Restroom In School Age Room 2 There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 28.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 "odify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set .esolution Not Set 'rogress Not Set .assignment Not Set $14,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 610 of 853 Record Number 30996 South Unisex Restroom In School Age Room 2 The entrance door swings into the turning space within the restroom. Finding 10.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $8,200 $0.00 Record Number 31004 South Unisex Restroom In School Age Room 2 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. 'riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 30998 South Unisex Restroom In School Age Room 2 Lavatory The height of the counter surface of the lavatory designated to be accessible in the restroom is greater than the allowed maximum height for the primary age group. Finding 30.50 inches Code Up to 29.00 inches ADA 4.19.2, CA 11B-606.2 Raise or replace the lavatory to provide the minimum required knee clearance. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 611 of 853 Record Number 30999 South Unisex Restroom In School Age Room 2 Lavatory The knee clearance space under the lavatory designated to be accessible in the restroom is less than the required minimum for the primary age group. Finding 23.50 inches Code At least 24.00 inches ADA 4.19.2, CA 11B-606.2 einstall or replace the lavatory designated to be accessible ith an accessible lavatory that provides the required knee earance for the primary age group. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 31000 South Unisex Restroom In School Age Room 2 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 13.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 31001 South Unisex Restroom In School Age Room 2 Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Thsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 612 of 853 Record Number 31002 South Unisex Restroom In School Age Room 2 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 31003 South Unisex Restroom In School Age Room 2 Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $158 $0.00 Record Number 30997 South Unisex Restroom In School Age Room 2 Soap The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 39.50 inches Code Up to 36.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 Relocate the dispenser in the restroom to meet the required eight for the primary age group. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 613 of 853 Record Number 31031 Girls Restroom In The Kindergarten Room The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31032 Girls Restroom In The Kindergarten Room There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 38.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 Modify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 31033 Girls Restroom In The Kindergarten Room The entrance door swings into the turning space within the restroom. Finding 9.50 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide sufficient clear floor space for a turning radius in the restroom to accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'rogress Not Set .assignment Not Set $8,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 614 of 853 Record Number 31040 Girls Restroom In The Kindergarten Room Female The gender use signage on the entrance door is not mounted at the required height. Finding 68.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 31035 Girls Restroom In The Kindergarten Room Lavatory The height of the counter surface of the lavatory designated to be accessible in the restroom is greater than the allowed maximum height for the primary age group. Finding 29.50 inches Code Up to 24.00 inches ADA 4.19.2, CA 11B-604.9 °aise or replace the lavatory to provide the minimum required lee clearance. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,286 $0.00 Record Number 31036 Girls Restroom In The Kindergarten Room Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 11.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 615 of 853 Record Number 31037 Girls Restroom In The Kindergarten Room Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 47.50 inches Code At least 48.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 elocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,261 $0.00 Record Number 31038 Girls Restroom In The Kindergarten Room Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. 'riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 31039 Girls Restroom In The Kindergarten Room Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 616 of 853 Record Number 31041 Girls Restroom In The Kindergarten Room There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Record Number 31034 Girls Restroom In The Kindergarten Room Soap The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 39.50 inches Code Up to 32.00 inches ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 elocate the dispenser in the restroom to meet the required eight for the primary age group. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 31082 North Unisex Restroom In School Age Room 2 There are grab bars missing from the toilet compartment. Finding None Found ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3 )stall the required compliant grab bars in the toilet ,.ompartment. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 617 of 853 Record Number 31083 North Unisex Restroom In School Age Room 2 The height of the toilet seat in the restroom is greater than the allowed maximum height for use by the primary age group. Finding 16.00 inches Code 15.00 inches ADA 4.16.7(3), CA 11B-604.9.3 djust or modify the height of the toilet seat in the restroom to le required height for use by the primary age group. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 31084 North Unisex Restroom In School Age Room 2 The distance from the center line of the toilet to the nearest side wall in the restroom is not at the required distance. Finding 18.00 inches on center Code 15.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance )r use by the primary age group. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 31086 North Unisex Restroom In School Age Room 2 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 22.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 618 of 853 Record Number 31087 North Unisex Restroom In School Age Room 2 There is less than the required minimum space in front of the toilet. Finding 30.50 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $3,500 $0.00 Record Number 31104 Mens Restroom The restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space to accommodate an individual in a wheelchair. Finding Not Accessible ADA 4.23 onsult a design professional to modify the restroom for access )mpliance. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 31106 Unisex Restroom In School Age Room 2 The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 56.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 619 of 853 Record Number 31105 Unisex Restroom In School Age Room 2 The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Record Number 31115 Unisex Restroom In School Age Room 2 The height of the side grab bar is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 Remount the grab bar so it is at the correct height. 'riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $500 $0.00 Record Number 31116 Unisex Restroom In School Age Room 2 The grab bar on the rear wall is not at the correct height. Finding 33.25 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 Remount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 620 of 853 Record Number 31112 Unisex Restroom In School Age Room 2 The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 1.25 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 31113 Unisex Restroom In School Age Room 2 The distance from the back wall to the front of the grab bar is less than required. Finding 46.50 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Record Number 31114 Unisex Restroom In School Age Room 2 The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 16.50 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 621 of 853 Record Number 31107 Unisex Restroom In School Age Room 2 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.25 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. Priority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 31109 Unisex Restroom In School Age Room 2 The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $127 $0.00 Record Number 31110 Unisex Restroom In School Age Room 2 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 36.25 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 622 of 853 Record Number 31111 Unisex Restroom In School Age Room 2 There is less than the required minimum space in front of the toilet. Finding 47.00 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $3,500 $0.00 Record Number 31117 Unisex Restroom In School Age Room 2 The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 19.00 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Record Number 31120 Girls Restroom In Kindergarten Room There are grab bars missing from the toilet compartment. Finding None Found ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3 (stall the required compliant grab bars in the toilet )mpartment. riority Not Set esolution Not Set 'rogress Not Set .,ssignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 623 of 853 Record Number 31119 Girls Restroom In Kindergarten Room The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 57.25 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 31121 Girls Restroom In Kindergarten Room The distance from the center line of the toilet to the nearest side wall is not compliant for the primary age group. Finding 20.00 inches on center Code 12.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance )r the primary age group. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 31123 Girls Restroom In Kindergarten Room The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 Relocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $127 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 624 of 853 Record Number 31124 Girls Restroom In Kindergarten Room The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 9.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 31125 Girls Restroom In Kindergarten Room There is less than the required minimum space in front of the toilet. Finding 29.00 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $3,500 $0.00 Record Number 31131 Boys Restroom In the Kindergarten Room There are grab bars missing from the toilet compartment. Finding None Found ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3 (stall the required compliant grab bars in the toilet )mpartment. riority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 625 of 853 Record Number 31130 Boys Restroom In the Kindergarten Room The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 59.50 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 31132 Boys Restroom In the Kindergarten Room The distance from the center line of the toilet to the nearest side wall is not compliant for the primary age group. Finding 18.50 inches on center Code 12.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance )r the primary age group. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 31134 Boys Restroom In the Kindergarten Room The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 Relocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $127 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 626 of 853 Record Number 31135 Boys Restroom In the Kindergarten Room The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 18.25 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 31136 Boys Restroom In the Kindergarten Room There is less than the required minimum space in front of the toilet. Finding 30.00 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $3,500 $0.00 Record Number 31137 Unisex Restroom In Classroom 2 There is insufficient clear floor space in the compartment. Finding 59.00 inches Code At least 60.00 inches ADA 4.17.3, ADA A4.17.3, CA 11B-604.8.1.1 odify or replace the compartment to provide adequate clear Dor space. riority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 627 of 853 Record Number 31139 Unisex Restroom In Classroom 2 There is no door on the compartment designated to be accessible in the restroom. Finding None Found ADA 4.17.5, CA 11B-604.8.1, CA 11B-604.8 (stall a door with appropriate accessible door hardware on the )mpartment designated to be accessible in the restroom. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 31138 Unisex Restroom In Classroom 2 Path of travel width to the accessible compartment is not compliant. Finding 41.00 inches Code At least 44.00 inches ADA A4.17.3, CA 11B-604.8.1.2 ake sure that the path of travel width to the accessible )mpartment is compliant. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,400 $0.00 Record Number 31143 Unisex Restroom In Classroom 2 The height of the side grab bar is not at a compliant height for the primary age group. Finding 33.00 inches Code 20.00 - 22.00 inches ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.9 emount the side grab bar in the compartment designated to e accessible in the restroom at to the required height for use y the primary age group. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $78 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 628 of 853 Record Number 31144 Unisex Restroom In Classroom 2 The grab bar on the rear wall is not at the correct height. Finding 33.00 inches Code 20.00 - 22.00 inches ADA 4.16.7(3), CA 11B-604.9 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. Priority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Record Number 31140 Unisex Restroom In Classroom 2 The distance from the center line of the toilet to the nearest side wall is not compliant for the primary age group. Finding 19.25 inches on center Code 12.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance )r the primary age group. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 31142 Unisex Restroom In Classroom 2 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 629 of 853 Record Number 31145 Unisex Restroom In Classroom 2 The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required (stance from the front edge of the toilet seat. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $78 $0.00 Record Number 31169 Boys Restroom In Pre -School Room 3 There are grab bars missing from the toilet compartment. Finding None Found ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3 (stall the required compliant grab bars in the toilet )mpartment. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $231 $0.00 Record Number 31168 Boys Restroom In Pre -School Room 3 The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 57.75 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 630 of 853 Record Number 31172 Boys Restroom In Pre -School Room 3 The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. tiority Not Set esolution Not Set rogress Not Set Assignment Not Set $127 $0.00 Record Number 31173 Boys Restroom In Pre -School Room 3 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 9.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set _,ssignment Not Set $2,500 $0.00 Record Number 31174 Boys Restroom In Pre -School Room 3 There is less than the required minimum space in front of the toilet. Finding 31.25 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 'Treate the required minimum clear space in front of the toilet. Priority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 631 of 853 Record Number 31170 Boys Restroom In Pre -School Room 3 The distance from the center line of the toilet to the nearest side wall is not compliant for the primary age group. Finding 18.00 inches on center Code 12.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance r the primary age group. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 31181 North Unisex Restroom In School Age Room 2 The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 Modify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31180 North Unisex Restroom In School Age Room 2 The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $804 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 632 of 853 Record Number 31182 North Unisex Restroom In School Age Room 2 There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 29.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 31183 North Unisex Restroom In School Age Room 2 The entrance door swings into the turning space within the restroom. Finding 10.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $8,200 $0.00 Record Number 31191 North Unisex Restroom In School Age Room 2 Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 633 of 853 Record Number 31192 North Unisex Restroom In School Age Room 2 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Record Number 31186 North Unisex Restroom In School Age Room 2 Lavatory The height of the counter surface of the lavatory designated to be accessible in the restroom is greater than the allowed maximum height for the primary age group. Finding 30.50 inches Code Up to 29.00 inches ADA 4.19.2, CA 11B-606.2 aise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 31187 North Unisex Restroom In School Age Room 2 Lavatory The knee clearance space under the lavatory designated to be accessible in the restroom is less than the required minimum for the primary age group. Finding 23.75 inches Code At least 24.00 inches ADA 4.19.2, CA 11B-606.2 einstall or replace the lavatory designated to be accessible ith an accessible lavatory that provides the required knee earance for the primary age group. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 634 of 853 Record Number 31188 North Unisex Restroom In School Age Room 2 Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 12.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required (stance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set esolution Not Set _:rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 31189 North Unisex Restroom In School Age Room 2 Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 lsulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or abrasive surfaces under the lavatory. riority Not Set esolution Not Set rogress Not Set ssignment Not Set $149 $0.00 Record Number 31190 North Unisex Restroom In School Age Room 2 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. riority Not Set esolution Not Set rogress Not Set assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 635 of 853 Record Number 31184 North Unisex Restroom In School Age Room 2 Soap The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 39.50 inches Code Up to 36.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 elocate the dispenser in the restroom to meet the required eight for the primary age group. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 31185 North Unisex Restroom In School Age Room 2 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 eplace dispenser with one that allows operation with one hand ld does not require tight grasping, pinching, or twisting of the rist. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Record Number 31193 South Unisex Restroom In School Age Room 2 There are grab bars missing from the toilet compartment. Finding None Found ADA 4.16.7(3), ADA 4.17.7(5), CA 11B-604.5, CA 11B-604.8.2.3 Install the required compliant grab bars in the toilet compartment. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 636 of 853 Record Number 31194 South Unisex Restroom In School Age Room 2 The height of the toilet seat in the restroom is greater than the allowed maximum height for use by the primary age group. Finding 15.50 inches Code 15.00 inches ADA 4.16.7(3), CA 11B-604.9.3 djust or modify the height of the toilet seat in the restroom to le required height for use by the primary age group. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 31195 South Unisex Restroom In School Age Room 2 The distance from the center line of the toilet to the nearest side wall in the restroom is not at the required distance. Finding 17.75 inches on center Code 15.00 inches on center ADA 4.16.7(1), CA 11B-604.9.1 elocate the toilet to provide a distance from the center line of le toilet to the nearest side that meets the required distance )r use by the primary age group. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,143 $0.00 Record Number 31197 South Unisex Restroom In School Age Room 2 The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 Relocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $127 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 637 of 853 Record Number 31198 South Unisex Restroom In School Age Room 2 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 20.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 31199 South Unisex Restroom In School Age Room 2 There is less than the required minimum space in front of the toilet. Finding 32.50 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $3,500 $0.00 Record Number 31202 Boys Restroom In the Kindergarten Room The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 638 of 853 Record Number 31203 Boys Restroom In the Kindergarten Room There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 40.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 31204 Boys Restroom In the Kindergarten Room The entrance door swings into the turning space within the restroom. Finding 8.50 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 Reverse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $8,200 $0.00 Record Number 31208 Boys Restroom In the Kindergarten Room Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 13.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 Replace or remount lavatory to meet the minimum required distance to the center line of the fixture, when located adjacent to a side wall or partition. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 639 of 853 Record Number 31209 Boys Restroom In the Kindergarten Room Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 47.00 inches Code At least 48.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 elocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,261 $0.00 Record Number 31210 Boys Restroom In the Kindergarten Room Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. 'riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 31211 Boys Restroom In the Kindergarten Room Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 640 of 853 Record Number 31207 Boys Restroom In the Kindergarten Room Lavatory The height of the counter surface of the lavatory designated to be accessible in the restroom is greater than the allowed maximum height for the primary age group. Finding 30.50 inches Code Up to 24.00 inches ADA 4.19.2, CA 11B-604.9 aise or replace the lavatory to provide the minimum required lee clearance. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 31213 Boys Restroom In the Kindergarten Room There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 31212 Boys Restroom In the Kindergarten Room Male The gender use signage on the entrance door is not mounted at the required height. Finding 67.00 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the . equired height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 641 of 853 Record Number 31205 Boys Restroom In the Kindergarten Room Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 eplace dispenser with one that allows operation with one hand -id does not require tight grasping, pinching, or twisting of the rist. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 31206 Boys Restroom In the Kindergarten Room Soap The height of the controls and operating mechanisms for the dispenser in the restroom is not compliant for the primary age group. Finding 39.50 inches Code Up to 32.00 inches ADA A4.2.5 & A4.2.6, ADA 4.23.7, ADA 4.22.7, CA 11B-604.9 elocate the dispenser in the restroom to meet the required eight for the primary age group. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Record Number 31223 Unisex Restroom In Classroom 2 The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 Install a compliant privacy lock with occupancy indicator to the door. riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $804 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 642 of 853 Record Number 31225 Unisex Restroom In Classroom 2 Lavatory The lavatory is in an enclosed cabinet, thereby preventing an accessible forward approach. Finding Not Accessible ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306 emove or modify the lavatory cabinet and provide a compliant vatory. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $420 $0.00 Record Number 31226 Unisex Restroom In Classroom 2 Lavatory The knee clearance space under the lavatory designated to be accessible in the restroom is less than the required minimum for the primary age group. Finding 17.00 inches Code At least 19.00 inches ADA 4.19.2, CA 11B-604.9 °einstall or replace the lavatory designated to be accessible ith an accessible lavatory that provides the required knee earance for the primary age group. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,286 $0.00 Record Number 31227 Unisex Restroom In Classroom 2 Lavatory There is not sufficient clear floor space provided to allow ar, accessible forward approach. Finding 27.00 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 Relocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,261 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 643 of 853 Record Number 31228 Unisex Restroom In Classroom 2 Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 31229 Unisex Restroom In Classroom 2 Lavatory There is not enough toe clearance at the restroom lavatory. Finding 3.50 inches Code At least 9.00 inches ADA 4.19.2 Provide minimum required toe clearance. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $289 $0.00 Record Number 31231 Unisex Restroom In Classroom 2 There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 644 of 853 Record Number 31230 Unisex Restroom In Classroom 2 Male There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Record Number 31224 Unisex Restroom In Classroom 2 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding Not Accessible ADA 4.27.4, ADA 309.4, CA 11B-603.5, CA 11B-309.4 eplace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. riority Not Set .esolution Not Set 'rogress Not Set .assignment Not Set $277 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30975 Drinking Fountain In The Courtyard There is less than the required minimum knee clearance height. Finding 22.50 inches Code At least 24.00 inches ADA 4.15.5, CA 11B-604.9 rovide a fountain with the required knee and toe clearances. riority Not Set .esolution Not Set rogress Not Set .assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 645 of 853 Record Number 30974 Drinking Fountain In The Courtyard The toe clearance is less than required. Finding 7.50 inches Code At least 9.00 inches ADA 4.15.5, CA 11B-602.2, CA 11B-305 rovide a fountain with the required knee and toe clearances. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30976 Drinking Fountain In The Courtyard The height of the water stream is less than required. Finding 0.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 Hdjust the flow of the water stream to a compliant height. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 30977 Drinking Fountain In The Courtyard The drinking fountain is not set entirely in an alcove. Finding None Found CA 11B-602.9 rovide compliant wing walls or barrier at the drinking fountain. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $640 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 646 of 853 Record Number 30973 Drinking Fountain In The Courtyard eplace the drinking fountain with a compliant High/Low )untain. $2,500 $0.00 The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set Play Area Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 31005 Kids Play Area Slide - Fibar The slope on the route to the transfer platform/play equipment is not compliant. Finding 99.00 percent Code Up to 6.37 percent Modify the slope of the route to transfer platform/play equipment. riority Not Set .esolution Not Set 'rogress Not Set ssignment Not Set $26 $0.00 Record Number 31006 Kids Play Area Slide - Fibar The vertical clearance height on route to the transfer platform/play equipment is not compliant. Finding 0.00 inches Code At least 80.00 inches Provide compliant vertical clearance. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 647 of 853 Record Number 31007 Kids Play Area Play Area Ground Equipment - Concrete/Solid Surface The surface beneath the play area is non -accessible to individuals with mobility impairments. Finding Not Accessible ADA 15.6 he play area should be made an accessible play area for the icility. Provide a maneuvering space with an accessible ?silient surface beneath the play components and adjacent to le play components where technically feasible. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $500 $0.00 Record Number 31008 Kids Play Area Play Area Ground Equipment - Concrete/Solid Surface Clear floor space at the ground level equipment is not compliant. Finding 0.00 inches Code At least 30.00 inches rovide compliant clear floor space at the ground level auipment. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,840 $0.00 Record Number 31009 Kids Play Area Play Area Ground Equipment - Concrete/Solid Surface The clear floor space at the ground level equipment is not firm and stable. Finding See Above rovide compliant clear floor space at the ground level auipment. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 648 of 853 Record Number 31010 Kids Play Area Play Area Ground Equipment - Wood Chips The surface beneath the play area is non -accessible to individuals with mobility impairments. Finding Not Accessible ADA 15.6 he play area should be made an accessible play area for the icility. Provide a maneuvering space with an accessible ?silient surface beneath the play components and adjacent to le play components where technically feasible. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $500 $0.00 Record Number 31011 Kids Play Area Play Area Ground Equipment - Wood Chips The slope on the route to the transfer platform/play equipment is not compliant. Finding 99.00 percent Code Up to 6.37 percent odify the slope of the route to transfer platform/play auipment. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $26 $0.00 Record Number 31012 Kids Play Area Play Area Ground Equipment - Wood Chips The clear floor space at the ground level equipment is not firrr stable. Finding See Above provide compliant clear floor space at the ground level auipment. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 649 of 853 Record Number 31013 Kids Play Area Play Area Ground Equipment - Fibar The clear floor space at the ground level equipment is not firm and stable. Finding See Above rovide compliant clear floor space at the ground level auipment. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,840 $0.00 Record Number 31014 Kids Play Area Play Area Ground Equipment - Fibar The clear floor space at the ground level equipment is not firm and stable. Finding See Above °rovide compliant clear floor space at the ground level auipment. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,840 $0.00 Record Number 31016 Kids Play Area Play Area Ground Equipment - Fibar The vertical clearance height on route to the transfer platform/play equipment is not compliant. Finding 45.00 inches Code At least 80.00 inches Provide compliant vertical clearance. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 650 of 853 Record Number 31015 Kids Play Area Play Area Ground Equipment - Fibar The clear floor space at the ground level equipment is not firm and stable. Finding See Above rovide compliant clear floor space at the ground level auipment. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,840 $0.00 Record Number 31017 Kids Play Area Play Area Ground Equipment - Fibar The clear floor space at the ground level equipment is not firm and stable. Finding See Above °rovide compliant clear floor space at the ground level auipment. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,840 $0.00 Record Number 31018 Kids Play Area Play Area Ground Equipment - Concrete/Solid Surface The surface beneath the play area is non -accessible to individuals with mobility impairments. Finding Not Accessible ADA 15.6 The play area should be made an accessible play area for the facility. Provide a maneuvering space with an accessible resilient surface beneath the play components and adjacent to the play components where technically feasible. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 651 of 853 Record Number 31019 rovide compliant clear floor space at the ground level auipment. $1,840 $0.00 Kids Play Area Play Area Ground Equipment - Concrete/Solid Surface The clear floor space at the ground level equipment is not firm and stable. Finding See Above riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Record Number 31020 Kids Play Area Play Area Ground Equipment - Concrete/Solid Surface The seat height is not compliant. Finding 25.00 inches Code 11.00 - 24.00 inches °rovide a compliant seat. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $445 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30817 Unisex Staff Restroom There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set 0 700 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 652 of 853 Record Number 30832 YMCA Daycare Center Ince visual warning devices are provided in all areas of the icility, no additional action is required. $0.00 There are visual warning devices provided throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 31101 Conference Room The table knee depth does not meet required standards. Finding 17.00 inches Code At least 19.00 inches ADA 4.27, CA 11B-306, CA 11B-902 provide compliant tables. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $2,174 $0.00 Record Number 31102 Conference Room The table knee width does not meet required standards. Finding 23.00 inches Code At least 30.00 inches ADA 4.27 "rovide compliant tables. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $2,174 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 653 of 853 Record Number 31103 Conference Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 30837 Sink In Kitchen Sink counter height is not compliant. Finding 35.75 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 provide compliant sink. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $1,800 $0.00 Record Number 30838 Sink In Kitchen Sink knee clearance does not meet the standards. Finding 25.75 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 "rovide compliant sink. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 654 of 853 Record Number 30839 Sink In Kitchen The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $420 $0.00 Record Number 30840 Sink In Kitchen The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Record Number 30841 Sink In Kitchen The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 655 of 853 Record Number 30842 Sink In Kitchen Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 44.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $180 $0.00 Record Number 30843 Sink In Kitchen Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 47.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $180 $0.00 Record Number 30844 Sink In Kitchen Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 Replace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $980 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 656 of 853 Record Number 30865 Sink In Pre -School Room 3 Sink counter height is not compliant. Finding 35.50 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 30866 Sink In Pre -School Room 3 Sink knee clearance does not meet the standards. Finding 26.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 30867 Sink In Pre -School Room 3 The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 Make sure there is no toe kick at the sink. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $420 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 657 of 853 Record Number 30868 Sink In Pre -School Room 3 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect aainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 30869 Sink In Pre -School Room 3 The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $190 $0.00 Record Number 30870 Sink In Pre -School Room 3 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 48.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set esolution Not Set 'rogress Not Set _assignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 658 of 853 Record Number 30871 Sink In Pre -School Room 3 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 eplace dispenser with one that allows operation with one hand ld does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $980 $0.00 Record Number 30872 Sink In Pre -School Room 3 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $180 $0.00 Record Number 30927 Sink In Classroom 1 Sink knee clearance does not meet the standards. Finding 25.75 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 Provide compliant sink. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 659 of 853 Record Number 30929 Sink In Classroom 1 There is not enough clear floor space at the sink. Finding 27.00 inches Code At least 30.00 inches ADA 4.27 rovide enough clear floor space at the location. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 30928 Sink In Classroom 1 There is not enough toe clearance at the sink. Finding 8.00 inches Code At least 9.00 inches ADA 4.27 rovide minimum required toe clearance. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 30930 Sink In Classroom 1 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 660 of 853 Record Number 30931 Sink In Classroom 1 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 eplace dispenser with one that allows operation with one hand ld does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $980 $0.00 Record Number 30932 Sink In Classroom 1 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $180 $0.00 Record Number 31021 Sink In School Age Room 2 Sink knee clearance does not meet the standards. Finding 25.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 Provide compliant sink. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 661 of 853 Record Number 31022 Sink In School Age Room 2 The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $420 $0.00 Record Number 31023 Sink In School Age Room 2 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Record Number 31024 Sink In School Age Room 2 The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 662 of 853 Record Number 31025 Sink In School Age Room 2 There is not enough clear floor space at the sink. Finding 21.00 inches Code At least 30.00 inches ADA 4.27 ,ovide enough clear floor space at the location. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 31026 Sink In School Age Room 2 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $180 $0.00 Record Number 31027 Sink In School Age Room 2 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 Replace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $980 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 663 of 853 Record Number 31042 Sink In Pre -School Room 2 Sink counter height is not compliant. Finding 35.25 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31043 Sink In Pre -School Room 2 Sink knee clearance does not meet the standards. Finding 26.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31044 Sink In Pre -School Room 2 The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 Make sure there is no toe kick at the sink. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $420 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 664 of 853 Record Number 31045 Sink In Pre -School Room 2 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect aainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 31046 Sink In Pre -School Room 2 The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $190 $0.00 Record Number 31047 Sink In Pre -School Room 2 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 665 of 853 Record Number 31048 Sink In Pre -School Room 2 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 eplace dispenser with one that allows operation with one hand ld does not require tight grasping, pinching, or twisting of the rist. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $980 $0.00 Record Number 31049 Sink In Pre -School Room 2 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $180 $0.00 Record Number 31062 Sink In Classroom 2 Sink knee clearance does not meet the standards. Finding 26.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 Provide compliant sink. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 666 of 853 Record Number 31064 Sink In Classroom 2 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 31063 Sink In Classroom 2 There is not enough toe clearance at the sink. Finding 6.00 inches Code At least 9.00 inches ADA 4.27 rovide minimum required toe clearance. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 31066 Sink In Classroom 2 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 eplace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $980 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 667 of 853 Record Number 31065 Sink In Classroom 2 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $180 $0.00 Record Number 31067 Sink In Classroom 2 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 41.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $180 $0.00 Record Number 31092 Sink In Kindergarten Room Sink counter height is not compliant. Finding 35.50 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 Provide compliant sink. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 668 of 853 Record Number 31093 Sink In Kindergarten Room Sink knee clearance does not meet the standards. Finding 26.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31094 Sink In Kindergarten Room The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $420 $0.00 Record Number 31095 Sink In Kindergarten Room The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 669 of 853 Record Number 31096 Sink In Kindergarten Room The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $190 $0.00 Record Number 31097 Sink In Kindergarten Room There is not enough clear floor space at the sink. Finding 27.00 inches Code At least 30.00 inches ADA 4.27 rovide enough clear floor space at the location. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 31098 Sink In Kindergarten Room Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 670 of 853 Record Number 31099 Sink In Kindergarten Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 47.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $180 $0.00 Record Number 31100 Sink In Kindergarten Room Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 Replace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. 'riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $980 $0.00 Record Number 31153 Sink In School Age Room 1 Sink knee clearance does not meet the standards. Finding 25.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 rovide compliant sink. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 671 of 853 Record Number 31154 Sink In School Age Room 1 The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 ake sure there is no toe kick at the sink. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $420 $0.00 Record Number 31155 Sink In School Age Room 1 The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect 3ainst contact. Make certain there are no sharp or abrasive arfaces under the sink. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Record Number 31156 Sink In School Age Room 1 The cabinet door hardware is not accessible. Finding None Found CA 11B-309 rovide compliant hardware for cabinet door. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 672 of 853 Record Number 31157 Sink In School Age Room 1 There is not enough clear floor space at the sink. Finding 21.00 inches Code At least 30.00 inches ADA 4.27 rovide enough clear floor space at the location. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 31158 Sink In School Age Room 1 Paper Towel The operable parts of the dispenser require tight grasping, pinching, or twisting of the wrist. Finding None Found ADA 4.27.4, CA 11B-309.4 eplace dispenser with one that allows operation with one hand id does not require tight grasping, pinching, or twisting of the rist. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $980 $0.00 Record Number 31159 Sink In School Age Room 1 Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 673 of 853 Record Number 31240 Sink In The Laundry Room Sink counter height is not compliant. Finding 36.00 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31241 Sink In The Laundry Room Sink knee clearance does not meet the standards. Finding 25.00 inches Code At least 27.00 inches ADA 4.27, CA 11B-606.2, CA 11B-306.3 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 31242 Sink In The Laundry Room The toe kick for the sink is not removed. Finding Toe Kick Exists CA 11B-606.2, CA 11B-305, CA 11B-306 Make sure there is no toe kick at the sink. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $420 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 674 of 853 Record Number 31243 Sink In The Laundry Room There is not enough clear floor space at the sink. Finding 45.00 inches Code At least 48.00 inches CA 11B-606.2 rovide enough clear floor space at the location. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 31146 Picnic Tables In The Courtyard The required percentage of picnic tables provided are not accessible. Finding None Found Code At least 1.00 tables ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 rovide a sufficient number of compliant picnic tables. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 675 of 853 New Fire Station (Fire Station #32) Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46429 Accessible Parking There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $250 $0.00 Record Number 46431 Accessible Parking Right Accessible Space Next To Corporation Yard There is no signage posted at the accessible parking space showing the International Symbol of Accessibility. Finding None Found ADA 4.6.4, CA 11B-502.6, CA 11B-703.7.2.1 rovide compliant sigange at the accessible space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $250 $0.00 Record Number 46430 Accessible Parking Right Accessible Space Next To Corporation Yard The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 e-stripe the existing parking space marked as accessible to efine the width of the space. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 676 of 853 Record Number 46432 Accessible Parking Right Accessible Space Next To Corporation Yard There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $300 $0.00 Record Number 46433 Accessible Parking Left Accessible Space Next To Corporation Yard The accessible parking space does not meet the minimum requirements for width. Finding 91.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $350 $0.00 Record Number 46434 Accessible Parking Left Accessible Space Next To Corporation Yard There is no signage posted at the accessible parking space showing the International Symbol of Accessibility. Finding None Found ADA 4.6.4, CA 11B-502.6, CA 11B-703.7.2.1 Provide compliant sigange at the accessible space. tiority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 677 of 853 Record Number 46435 Accessible Parking Left Accessible Space Next To Corporation Yard There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $300 $0.00 Record Number 46436 Accessible Parking Left Accessible Space Next To Corporation Yard The access aisle does not meet the minimum required width. Finding 92.00 inches Code At least 96.00 inches ADA 4.1.2(5) e-stripe the access aisle. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 46437 Accessible Parking Right Accessible Space Next To The Main Entrance The accessible parking space does not meet the minimum requirements for width. Finding 102.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 Re -stripe the accessible parking space. tiority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 678 of 853 Record Number 46438 Accessible Parking Right Accessible Space Next To The Main Entrance There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. tiority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $300 $0.00 Record Number 46439 Accessible Parking Left Accessible Space Next To The Main Entrance The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 e-stripe the existing parking space marked as accessible to fine the width of the space. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $350 $0.00 Record Number 46440 Accessible Parking Left Accessible Space Next To The Main Entrance The access aisle does not meet the minimum required width. Finding 91.00 inches Code At least 96.00 inches ADA 4.1.2(5) e-stripe the access aisle. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $250 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 679 of 853 Record Number 46442 Main Entrance Next To Reception The clear opening width of the door is less than required. Finding 30.58 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 46444 Unisex Restroom Next To IT Room Push Side There is less than the required latch side clearance on the push side of the door. Finding 4.75 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 46443 Unisex Restroom Next To IT Room Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force quirements. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $25 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 680 of 853 Record Number 46450 Directional Signage From The Public Right Of Way There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 46445 Main Entrance Next To Reception Exit The accessible entrance signage attached to the wall is not at the required location. Finding Mount Location Incorrect ADA 4.30.6, CA 11B-703.4.2 rovide compliant signage identifying the accessible entrance on le wall adjacent to the latch side of the doorway, mounted at le required height and location. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $50 $0.00 Record Number 46446 Door From Main Entrance Lobby To Hallway There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 Install compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 681 of 853 Record Number 46448 Main Entrance Next To Reception There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 46449 Directional Signage To All Common Areas There is no informational signage. ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall informational signage to each accessible element or room location. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46420 Unisex Restroom Next To IT Room The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 44.50 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 ' ower the mirror so the bottom edge of the reflective surface is 3 higher than recommended above the finished floor. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 682 of 853 Record Number 46418 Unisex Restroom Next To IT Room Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 46419 Unisex Restroom Next To IT Room Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 46421 Unisex Restroom Next To IT Room There is no signage with the International Symbol of Accessibility. Finding None Found ADA 4.30.4, CA 11B-703.7 Tnstall signage that includes the International Symbol of Accessibility. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 683 of 853 Record Number 46427 Unisex Restroom Next To IT Room The coat hook is not mounted at the correct height. Finding 72.00 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. tiority Not Set .esolution Not Set rogress Not Set Assignment Not Set $50 $0.00 Record Number 46426 Unisex Restroom Next To IT Room The distance from the back wall to the front of the grab bar is less than required. Finding 53.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Record Number 46428 Unisex Restroom Next To IT Room The toilet paper dispenser is not mounted at the required height. Finding 17.25 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 684 of 853 Record Number 46423 Unisex Restroom Next To IT Room The height of the toilet seat is not at the required height. Finding 16.00 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,707 $0.00 Record Number 46422 Unisex Restroom Next To IT Room The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 17.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 46425 Unisex Restroom Next To IT Room The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 29.50 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 685 of 853 Record Number 46417 Visual Alarms There are some visual warning devices, though visual warning devices are not located throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, classrooms and eneral use rooms, accessible restrooms and other accessible )oms. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $2,200 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 46447 Outdoor BBQ Area BBQ Grill - Other Element controls are non accessible. Finding None Found ADA 4.11, CA 11B-309.4 'rovide compliant controls for the element. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Record Number 46441 Laundry Room Washer/Dryers - Other Element controls are non accessible. Finding None Found ADA 4.11, CA 11B-309.4 ^rovide compliant controls for the element. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 686 of 853 Police Substation Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29430 Parking Lot Off Avenida Navarro & 1 Space Off Avenida Bermudas The location of the accessible parking space is not located on the shortest accessible route of travel to the facility for which it serves. Finding Not on Path ADAG 4.6.2, CA 11B-208.2 elocate the designated accessible parking space to the iortest accessible route of travel to the facility for which it rves. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $1,379 $0.00 Record Number 29434 Parking Lot Off Avenida Navarro & 1 Space Off Avenida Bermudas Parking Lot Warning Sign The point of contact and telephone number for reclaiming towed vehicles have been left blank. Finding Sign not Filled CA 11B-502.8.2 II in the blank spaces with the point of contact and telephone umber for reclaiming towed vehicles. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 687 of 853 Record Number 29432 Parking Lot Off Avenida Navarro & 1 Space Off Avenida Bermudas Accessible Space The access aisle does not meet the minimum required width. Finding 93.00 inches Code At least 96.00 inches ADA 4.1.2(5) e-stripe the access aisle. riority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $250 $0.00 Record Number 29433 Parking Lot Off Avenida Navarro & 1 Space Off Avenida Bermudas Accessible Space The access aisle markings are faded, damaged, or otherwise not viewable. Finding None Found CA 11B-502.3 Re -stripe the access aisle so as to discourage parking. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 29431 Parking Lot Off Avenida Navarro & 1 Space Off Avenida Bermudas Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 38.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Dace. riority Not Set esolution Not Set 'regress Not Set ssignment Not Set $220 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 688 of 853 Record Number 28570 Path Of Travel From The Public Right Of Way Off Avenida Bermudas Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 5.30 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $3,600 $0.00 Record Number 28580 Path Of Travel From The Public Right Of Way Off Avenida Navarro Path Of Travel From The Public Right Of Way There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 -'rovide detectable warnings. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $190 $0.00 Record Number 28581 Path Of Travel From The Public Right Of Way Off Avenida Navarro Path Of Travel From The Public Right Of Way The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 Provide a compliant crosswalk. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,100 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 689 of 853 Record Number 28586 Gate From Parking Lot To Walkway To Avenida Bermudas The clear opening width of the gate is not compliant. Finding 52.00 inches Code Up to 48.00 inches rovide a compliant gate at the location. tiority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 28391 Traffic Office The clear opening width of the door is less than required. Finding 27.00 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 28392 Traffic Office The vertical clearance height of the door is less than required. Finding 77.50 inches Code At least 78.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 )(tend the height of the doorway to provide the required earance height. tiority Not Set esolution Not Set 'rogress Not Set .,ssignment Not Set $2,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 690 of 853 Record Number 28394 Traffic Office Push Side There is not enough clear floor space provided at the push side of the door . Finding 39.50 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. tiority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $4,000 $0.00 Record Number 28393 Traffic Office Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 °rovide accessible hardware on the door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28412 Unisex Restroom The clear opening width of the door is less than required. Finding 25.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 '^liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 691 of 853 Record Number 28413 Unisex Restroom The vertical clearance height of the door is less than required. Finding 77.50 inches Code At least 78.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 tend the height of the doorway to provide the required earance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,000 $0.00 Record Number 28417 Unisex Restroom Push Side There is not enough clear floor space provided at the push side of the door . Finding 35.00 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,000 $0.00 Record Number 28418 Unisex Restroom Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 55.50 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. 'riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 692 of 853 Record Number 28416 Unisex Restroom Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 3.25 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 28414 Unisex Restroom Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 °rovide accessible hardware on the door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28415 Unisex Restroom Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 nrovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. tiority Not Set .esolution Not Set 'rogress Not Set _.ssignment Not Set $310 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 693 of 853 Record Number 28464 Open Doorway In Office Hallway The clear opening width of the doorway is not compliant. Finding 30.25 inches Code At least 32.00 inches ADA 4.13.5 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,800 $0.00 Record Number 28463 Open Doorway In Office Hallway The vertical clearance height of the open doorway is not compliant. Finding 78.50 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. tiority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $5,600 $0.00 Record Number 28508 Right Hallway Office The clear opening width of the door is less than required. Finding 27.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 694 of 853 Record Number 28510 Right Hallway Office Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Not Set .esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28511 Right Hallway Office Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Record Number 28556 Open Doorway Between Reception & Office Hallway The clear opening width of the doorway is not compliant. Finding 28.25 inches Code At least 32.00 inches ADA 4.13.5 Eiden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 695 of 853 Record Number 28555 Open Doorway Between Reception & Office Hallway The vertical clearance height of the open doorway is not compliant. Finding 78.00 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. tiority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $5,600 $0.00 Record Number 28583 Left Hallway Office The clear opening width of the door is less than required. Finding 27.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 28585 Left Hallway Office Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 Provide accessible hardware on the door. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 696 of 853 Record Number 28587 Main Entrance Off Avenida Bermudas The vertical clearance height of the door is less than required. Finding 77.00 inches Code At least 78.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 tend the height of the doorway to provide the required earance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,000 $0.00 Record Number 28590 Main Entrance Off Avenida Bermudas The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Record Number 28589 Main Entrance Off Avenida Bermudas The bottom of the door does not provide a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Finding 7.50 inches Code At least 10.00 inches CA 11B-404.2.10 (stall a panel or replace the door to provide a smooth, ninterrupted surface at the bottom of the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 697 of 853 Record Number 28588 Main Entrance Off Avenida Bermudas Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Not Set esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28651 Door Between Reception Lobby & Picnic Area The clear opening width of the door is less than required. Finding 27.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set esolution Not Set 'regress Not Set .ssignment Not Set $1,750 $0.00 Record Number 28652 Door Between Reception Lobby & Picnic Area The vertical clearance height of the door is less than required. Finding 77.50 inches Code At least 78.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 )(tend the height of the doorway to provide the required earance height. tiority Not Set esolution Not Set 'regress Not Set .,ssignment Not Set $2,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 698 of 853 Record Number 28653 Door Between Reception Lobby & Picnic Area Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28654 Door Between Reception Lobby & Picnic Area The height of the threshold at the entrance door is greater than allowed. Finding 3.25 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28499 Reception Counter The height of the counter or desk does not comply with height requirements. Finding 42.25 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $3,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 699 of 853 Record Number 28500 Reception Counter The counter is a protruding object. Finding See Above ADA 4.32.4, ADA 7.2 djust the counter so that it is no longer a protruding object. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $450 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28431 Gate From Parking Lot To Walkway To Avenida Bermudas There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 istall compliant room identification signage. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Record Number 28617 Directional Signage From The Public Right Of Way Off Avenida Navarro There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 Install directional signage to each accessible element or room. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 700 of 853 Record Number 28656 Directional Signage From Parking Lot To Avenida Bermudas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28390 Open Doorway Between Reception & Office Hallway There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28395 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 (stall directional signage to each accessible element or room. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 701 of 853 Record Number 28406 Right Hallway Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28465 Open Doorway In Office Hallway There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28480 Door Between Reception Lobby & Picnic Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 702 of 853 Record Number 28558 Left Hallway Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28567 Traffic Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28573 Main Entrance Off Avenida Bermudas There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 install accessible room signage. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 703 of 853 Record Number 28423 Unisex Restroom There are no grab bars. Finding None Found ADA 4.17.6, ADA 4.16.4, CA 11B-604.5 (stall the required grab bars in the toilet compartment. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $267 $0.00 Record Number 28422 Unisex Restroom The clearance around the water closet measured perpendicular from the side wall is not compliant. Finding 55.75 inches Code At least 60.00 inches ADA 4.16.2 rovide a compliant clearance around the water closet ieasured perpendicular from the rear wall. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 28425 Unisex Restroom The height of the toilet seat is not at the required height. Finding 14.75 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. tiority Not Set esolution Not Set 'rogress Not Set .,ssignment Not Set $1,707 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 704 of 853 Record Number 28424 Unisex Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 14.00 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. Priority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 28427 Unisex Restroom The flush control on the toilet is not on the wide (approach) side of the toilet. Finding Wrong Side of Toilet ADA 4.16.5, CA 11B-604.6 elocate the flush control so it is on the wide (approach) side of le toilet area. Flush controls shall be hand -operated or atomatic mechanisms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $127 $0.00 Record Number 28428 Unisex Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 13.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 705 of 853 Record Number 28429 Unisex Restroom There is less than the required minimum space in front of the toilet. Finding 34.00 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. tiority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $3,500 $0.00 Record Number 28430 Unisex Restroom The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required stance from the front edge of the toilet seat. tiority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $78 $0.00 Record Number 29437 Unisex Restroom The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. tiority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 706 of 853 Record Number 29436 Unisex Restroom The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. Priority Not Set esolution Not Set rogress Not Set Assignment Not Set $804 $0.00 Record Number 29438 Unisex Restroom There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 42.50 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 29439 Unisex Restroom The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 Provide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 707 of 853 Record Number 29440 Unisex Restroom The entrance door swings into the turning space within the restroom. Finding 27.50 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $8,200 $0.00 Record Number 29449 Unisex Restroom The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 51.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 I ower the mirror so the bottom edge of the reflective surface is i to higher than recommended above the finished floor. riority Not Set .esolution Not Set 'rogress Not Set _,ssignment Not Set $300 $0.00 Record Number 29450 Unisex Restroom The top of the mirror is not at the compliant height. Finding 73.75 inches Code At least 74.00 inches ADA 4.19.6 Provide a compliant mirror in the restroom. 'riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 708 of 853 Record Number 29442 Unisex Restroom Lavatory The lavatory is in an enclosed cabinet, thereby preventing an accessible forward approach. Finding Not Accessible ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306 emove or modify the lavatory cabinet and provide a compliant vatory. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $420 $0.00 Record Number 29443 Unisex Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 23.62 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 Raise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,286 $0.00 Record Number 29444 Unisex Restroom Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 14.00 inches on center Code At least 18.00 inches on center CA 11B-606.6 Replace or remount lavatory to meet the minimum required 'lstance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set .esolution Not Set .rogress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 709 of 853 Record Number 29445 Unisex Restroom Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 22.25 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 elocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,261 $0.00 Record Number 29446 Unisex Restroom Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 42.50 inches Code At least 48.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 Relocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,261 $0.00 Record Number 29447 Unisex Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. 'riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 710 of 853 Record Number 29448 Unisex Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $149 $0.00 Record Number 29452 Unisex Restroom There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 Provide compliant signage on latch side of door. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $158 $0.00 Record Number 29451 Unisex Restroom All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the . equired height. riority Not Set .esolution Not Set 'regress Not Set ..ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 711 of 853 Record Number 29441 Unisex Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 53.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $277 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28571 Visual Alarms There are no visual warning devices at the facility. Finding None Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 Install visual warning devices integrated with the facility's alarm system in all common areas. Priority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,200 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28591 Picnic Table No ISA Symbol was found at the picnic table. Finding None Found ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 dd a compliant ISA symbol at the picnic table. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 712 of 853 Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28410 Benches The bench height is not compliant. Finding 15.25 inches Code 17.00 - 19.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench height to recommended value. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $800 $0.00 Record Number 28411 Benches The bench back rest height is not compliant. Finding 17.00 inches Code At least 18.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench back rest height to recommended value. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $800 $0.00 Rooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 29435 Police Substation The tub is not accessible. Finding Not Designated ADA 9.1 rovide a compliant accessible tub. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,765 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 713 of 853 Public Works & Maintenance Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28563 City Vehicle Parking Lot There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $250 $0.00 Record Number 28562 City Vehicle Parking Lot The minimum number of accessible parking spaces are not provided in the parking lot. Finding None Found ADA 4.1.2(5), CA 118-208.2, CA 118-502 e-stripe any existing parking spaces marked accessible and -eate additional accessible parking spaces. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $370 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 714 of 853 Record Number 28615 rovide detectable warnings. $190 $0.00 Path Of Travel From The Public Right Of Way Off Frances Hack Lane Path Of Travel From The Public Right Of Way There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Record Number 28616 Path Of Travel From The Public Right Of Way Off Frances Hack Lane Path Of Travel From The Public Right Of Way The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 rovide a compliant crosswalk. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,100 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28546 Stairs To Corporation Yard Office Building Stairway is marked as primary access. There is no other means of vertical access. Finding No Access ADA 4.3.11.3, CA 11B-206.2, CA 11B-210, CA 11B-402.2, CA 11B -504 rovide a compliant means of vertical access. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $4,816 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 715 of 853 Record Number 28547 Stairs To Corporation Yard Office Building Run 1 The width of the stairway does not meet the minimum required width. Finding 40.25 inches Code At least 44.00 inches ADA 4.3.11.3, CA 11B-1009.1, CA 11B-210, CA 11B-504 (stall a stairway with a minimum width as required. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,816 $0.00 Record Number 28548 Stairs To Corporation Yard Office Building Run 1 There is no handrail provided on one side of the stairway. Finding None Found ADA 4.9.4, CA 11B-504.6, CA 11B-505.2 Provide compliant handrails on the stairway. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,528 $0.00 Record Number 28549 Stairs To Corporation Yard Office Building Run 1 The risers on the stairway are open. Finding Not Closed ADA 4.9.2, CA 11B-504.3 lose the riser openings on the stairway. Open risers are not ermitted. 'riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $480 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 716 of 853 Record Number 28550 Stairs To Corporation Yard Office Building Run 1 There is no detectable striping on the stairways. Finding None Found ADA 4.9.5, CA 11B-504.4.1 ffix compliant contrasting striping to the upper approach and 3ch tread that is the correct width and distance from the Dsing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,000 $0.00 Record Number 28551 Stairs To Corporation Yard Office Building Run 1 Right Handrail The diameter of the handrail is not within the required range. Finding 1.00 inches Code 1.25 - 2.00 inches ADA 4.26.2, CA 11B-505.7 °rovide a compliant handrail with a diameter within the required Inge. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,320 $0.00 Record Number 28552 Stairs To Corporation Yard Office Building Run 1 Right Handrail There are no bottom handrail extensions provided. Finding None Found ADA 4.9.4(2), CA 11B-505.10.3 Install handrail extension to the bottom of the handrail that Ktends beyond the bottom riser at least one tread depth. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,425 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 717 of 853 Record Number 28420 Conference Room Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. tiority Not Set .esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28421 Conference Room Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Record Number 28432 Corporation Yard Office Building Entrance The door closing device limits the required headroom clearance. Finding 78.26 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 718 of 853 Record Number 28436 Corporation Yard Office Building Entrance Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 2.50 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance for the door. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 28437 Corporation Yard Office Building Entrance Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 41.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 Provide the recommended clear floor space on the pull side of 'ie door. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 28435 Corporation Yard Office Building Entrance The height of the threshold at the entrance door is greater than allowed. Finding 1.12 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 719 of 853 Record Number 28434 Corporation Yard Office Building Entrance Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28466 Unisex Restroom In Corporation Yard Office Building Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28467 Unisex Restroom In Corporation Yard Office Building Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require ght grasping, pinching, or twisting of the wrist to operate. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 720 of 853 Record Number 28507 Door Between Conference Room & Office Push Side There is not enough clear floor space provided at the push side of the door . Finding 32.50 inches Code At least 48.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended clear floor space on the push side of le door. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 28505 Door Between Conference Room & Office Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 °rovide accessible hardware on the door. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28506 Door Between Conference Room & Office Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 provide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Not Set esolution Not Set 'rogress Not Set _.ssignment Not Set $310 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 721 of 853 Record Number 28543 Break Room The vertical clearance height of the open doorway is not compliant. Finding 79.75 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $5,600 $0.00 Record Number 28544 Left & Right Training Room Doors Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28545 Left & Right Training Room Doors Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require ght grasping, pinching, or twisting of the wrist to operate. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 722 of 853 Record Number 28648 4 Office Doors Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28649 4 Office Doors Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Record Number 28537 Gate From Frances Hack Lane To City Vehicle Parking Lot Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 723 of 853 Record Number 28564 Gate From Shared Fire Station Parking Lot To Corporation Yard Push Side There is no level landing at this door. Finding 2.50 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $1,500 $0.00 Record Number 28388 Open Doorway Between Reception Area & Locker Area The clear opening width of the doorway is not compliant. Finding 29.00 inches Code At least 32.00 inches ADA 4.13.5 Widen the door opening and install a door that provides at least 'ie minimum clear width with the door open 90 degrees. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,800 $0.00 Record Number 28387 Open Doorway Between Reception Area & Locker Area The vertical clearance height of the open doorway is not compliant. Finding 79.00 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $5,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 724 of 853 Record Number 28443 Right Entrance Push Side There is less than the required latch side clearance on the push side of the door. Finding 10.50 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 28442 Right Entrance The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "lodify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set .assignment Not Set $436 $0.00 Record Number 28441 Right Entrance Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 provide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 725 of 853 Record Number 28451 Door Between Work Area & Bay The clear opening width of the door is less than required. Finding 28.00 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 28452 Door Between Work Area & Bay The vertical clearance height of the door is less than required. Finding 77.50 inches Code At least 78.00 inches ADA 4.4.2, CA 11B-307, CA 11B-404, CA 11B-404.2.3 tend the height of the doorway to provide the required earance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,000 $0.00 Record Number 28455 Door Between Work Area & Bay Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 11.50 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 726 of 853 Record Number 28453 Door Between Work Area & Bay Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $800 $0.00 Record Number 28454 Door Between Work Area & Bay Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Record Number 28460 Door Between Picnic Area & Work Area Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 58.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $2,921 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 727 of 853 Record Number 28459 Door Between Picnic Area & Work Area Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 19.00 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance for the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 28458 Door Between Picnic Area & Work Area Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 Provide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28542 Door Between Picnic Area & Locker Area Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 9.62 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the Dor. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $4,000 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 728 of 853 Record Number 28541 Door Between Picnic Area & Locker Area The height of the threshold at the entrance door is greater than allowed. Finding 1.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Record Number 28539 Door Between Picnic Area & Locker Area Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 rovide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28540 Door Between Picnic Area & Locker Area Single Knob The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding Not Accessible ADA 404.2.7, ADA 309.4 rovide a compliant door lock for the door that does not require ght grasping, pinching, or twisting of the wrist to operate. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $310 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 729 of 853 Record Number 28554 Door Between Left Entrance & Reception Area Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 32.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 28553 Door Between Left Entrance & Reception Area None Door hardware is not mounted at the correct height. Finding 24.00 inches Code 30.00 - 44.00 inches ADA 309.4, ADA 404.2.7, CA 11B-404.2.7 "fount the door hardware at the recommended height. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $280 $0.00 Record Number 28599 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The clear opening width of the door is less than required. Finding 29.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 '^liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 730 of 853 Record Number 28647 Gate To Picnic Area Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 47.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 28645 Gate To Picnic Area Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 °rovide accessible hardware on the door. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28646 Gate To Picnic Area Single Knob The bottom of the door or gate does not provide a smooth surface on the push side extending the full width of the door or gate. Finding None Found CA 11B-404.2 Install a smooth uninterrupted surface or panel on the push de, extending the full width of the door or gate. riority Not Set .esolution Not Set 'rogress Not Set _.ssignment Not Set $400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 731 of 853 Record Number 28663 Left Entrance Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 8.00 inches Code At least 18.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide required latch side clearance on the pull side of the tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $4,000 $0.00 Record Number 28661 Left Entrance Single Knob The door opening hardware is not accessible. Finding Not Accessible ADA 404.2.7, CA 11B-404.2.7 °rovide accessible hardware on the door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Record Number 28662 Left Entrance The height of the threshold at the entrance door is greater than allowed. Finding 1.00 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 "^odify or replace the threshold to provide the recommended eight. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 732 of 853 Record Number 28479 Reception Counter The height of the counter or desk does not comply with height requirements. Finding 42.50 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 rovide a portion of counter at the compliant height. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $3,500 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28419 Corporation Yard Office Building Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 Tnstall accessible room signage. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Record Number 28502 Directional Signage To All Common Areas There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 Install directional signage to each accessible element or room. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 733 of 853 Record Number 28568 4 Office Doors There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28572 Break Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28575 Conference Room There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 734 of 853 Record Number 28618 Door Between Conference Room & Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28655 Left & Right Training Room Doors There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28389 Right Entrance There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 735 of 853 Record Number 28534 Left Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 lstall accessible room signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28559 Door Between Picnic Area & Locker Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28569 Gate To Picnic Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 736 of 853 Record Number 28576 Door Between Work Area & Bay There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 28582 Open Doorway Between Reception Area & Locker Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 lstall compliant room identification signage. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28650 Door Between Picnic Area & Work Area There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 install compliant room identification signage. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 737 of 853 Record Number 28790 Unisex Restroom In Corporation Yard Office Building The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 (stall a compliant privacy lock with occupancy indicator to the Dor. Priority Not Set esolution Not Set rogress Not Set Assignment Not Set $804 $0.00 Record Number 28791 Unisex Restroom In Corporation Yard Office Building There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair. Finding 55.00 inches Code At least 60.00 inches ADA 4.2.3, ADA 4.22.3, ADA 304.3.1, ADA 603.2, CA 11B-304.3 odify the restroom to provide sufficient clear floor space for a irning radius in the restroom to accommodate an individual in wheelchair. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $14,000 $0.00 Record Number 28792 Unisex Restroom In Corporation Yard Office Building The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 Provide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 738 of 853 Record Number 28801 Unisex Restroom In Corporation Yard Office Building The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 47.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $300 $0.00 Record Number 28802 Unisex Restroom In Corporation Yard Office Building The top of the mirror is not at the compliant height. Finding 66.50 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $250 $0.00 Record Number 28800 Unisex Restroom In Corporation Yard Office Building Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or jrasive surfaces under the lavatory. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 739 of 853 Record Number 28795 Unisex Restroom In Corporation Yard Office Building Lavatory The lavatory is in an enclosed cabinet, thereby preventing an accessible forward approach. Finding Not Accessible ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306 emove or modify the lavatory cabinet and provide a compliant vatory. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $420 $0.00 Record Number 28796 Unisex Restroom In Corporation Yard Office Building Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 25.25 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 Raise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,286 $0.00 Record Number 28797 Unisex Restroom In Corporation Yard Office Building Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 12.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 Replace or remount lavatory to meet the minimum required 'lstance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set .esolution Not Set .rogress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 740 of 853 Record Number 28798 Unisex Restroom In Corporation Yard Office Building Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 22.00 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 elocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,261 $0.00 Record Number 28799 Unisex Restroom In Corporation Yard Office Building Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. 'riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 28803 Unisex Restroom In Corporation Yard Office Building All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the quired height. 'riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 741 of 853 Record Number 28804 Unisex Restroom In Corporation Yard Office Building There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Record Number 28793 Unisex Restroom In Corporation Yard Office Building Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 55.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 28794 Unisex Restroom In Corporation Yard Office Building Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 51.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set _assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 742 of 853 Record Number 28603 Unisex Restroom In Corporation Yard Office Building The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Record Number 28602 Unisex Restroom In Corporation Yard Office Building There is no back grab bar at the toilet compartment. Finding None Found ADA 4.17.6, CA 11B-604.5, CA 11B-604.8.1.5 rnstall the required grab bars in the toilet compartment. 'riority Not Set esolution Not Set rogress Not Set Assignment Not Set $267 $0.00 Record Number 28601 Unisex Restroom In Corporation Yard Office Building The location of the seat cover dispenser does not provide sufficient clear floor space. Finding Not Accessible ADA 4.2, CA 11B-603.5, CA 11B-309.2, CA 11B-305.1 Relocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 743 of 853 Record Number 28608 Unisex Restroom In Corporation Yard Office Building The length of the side grab bar is less than required. Finding 36.00 inches Code At least 42.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1 eplace the side grab bar with a compliant grab bar. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $267 $0.00 Record Number 28612 Unisex Restroom In Corporation Yard Office Building The height of the side grab bar is not at the correct height. Finding 31.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Record Number 28609 Unisex Restroom In Corporation Yard Office Building The distance from the rear wall to the side grab bar is greater than allowed. Finding 16.00 inches Code Up to 12.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1 emount the side grab bar so it meets the distance ?quirements from the back wall. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 744 of 853 Record Number 28610 Unisex Restroom In Corporation Yard Office Building The distance from the back wall to the front of the grab bar is less than required. Finding 52.00 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Record Number 28611 Unisex Restroom In Corporation Yard Office Building The distance from the front edge of the toilet to the front edge of the side grab bar is insufficient. Finding 21.00 inches Code At least 24.00 inches CA 11B-604.5.1 (stall or relocate the side grab bar so that the distance from le front edge of the toilet to the front edge of the side grab ar meets the required minimum distance. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Record Number 28604 Unisex Restroom In Corporation Yard Office Building The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 20.00 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'rogress Not Set .-ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 745 of 853 Record Number 28606 Unisex Restroom In Corporation Yard Office Building The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 23.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 28607 Unisex Restroom In Corporation Yard Office Building There is less than the required minimum space in front of the toilet. Finding 47.50 inches Code At least 48.00 inches ADA 4.16.2, ADA 4.17.3, CA 11B-604.8.1 reate the required minimum clear space in front of the toilet. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $3,500 $0.00 Record Number 28613 Unisex Restroom In Corporation Yard Office Building The toilet paper dispenser interferes with the use of the grab bar. Finding Interferes ADA 4.16.6, CA 11B-309.4, CA 11B-609.3 elocate the toilet paper dispenser so it does not interfere with le use of a grab bar. Toilet paper dispensers must allow )ntinuous paper flow. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 746 of 853 Record Number 28773 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The entrance door swings inward at the restroom, thereby limiting the minimum amount of clear floor space. Finding Reduced CFS ADA 4.2.3, ADA 4.22.3, CA 11B-603.2.1, CA 11B-304.4 odify the restroom to provide sufficient clear floor space for a arning radius in the restroom to accommodate an individual in wheelchair. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $1,800 $0.00 Record Number 28772 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The restroom door does not provide a compliant privacy lock with occupancy indicator. Finding None Found CA 11B-213.2.1 Install a compliant privacy lock with occupancy indicator to the ' Dor. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $804 $0.00 Record Number 28774 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The door lock requires tight grasping, pinching, or twisting of the wrist to operate. Finding None Found ADA 4.2.3, ADA 4.22.3, ADA 404.2.7, ADA 309.4, CA 11B-404.2.7 , CA 11B-309.4 Provide a compliant door lock for the door that does not require aht grasping, pinching, or twisting of the wrist to operate. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $280 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 747 of 853 Record Number 28775 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The entrance door swings into the turning space within the restroom. Finding 40.00 inches Code At least 48.00 inches ADA 4.2.3, CA 11B-603.2.3 everse the door swing, or modify the restroom to provide efficient clear floor space for a turning radius in the restroom accommodate an individual in a wheelchair. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $8,200 $0.00 Record Number 28787 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The height of the urinal rim in the restroom is not compliant. Finding 26.00 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 Lower the urinal designated to be accessible in the restroom so 'bat the rim height is compliant. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $1,397 $0.00 Record Number 28785 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 47.25 inches Code Up to 40.00 inches ADA 4.19.6, CA 11B-603.3 )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 748 of 853 Record Number 28786 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The top of the mirror is not at the compliant height. Finding 72.50 inches Code At least 74.00 inches ADA 4.19.6 rovide a compliant mirror in the restroom. riority Not Set .esolution Not Set 'regress Not Set _,ssignment Not Set $250 $0.00 Record Number 28784 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory There is not enough toe clearance at the restroom lavatory. Finding 8.50 inches Code At least 9.00 inches ADA 4.19.2 rovide minimum required toe clearance. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $289 $0.00 Record Number 28778 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory The lavatory is in an enclosed cabinet, thereby preventing an accessible forward approach. Finding Not Accessible ADA 4.19.2, CA 11B-606.2, CA 11B-305, CA 11B-306 Remove or modify the lavatory cabinet and provide a compliant vatory. 'riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $420 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 749 of 853 Record Number 28779 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 25.25 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 28780 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory The lavatory center line does not meet the minimum required distance when located adjacent to a side wall, partition or fixture. Finding 12.50 inches on center Code At least 18.00 inches on center CA 11B-606.6 eplace or remount lavatory to meet the minimum required stance to the center line of the fixture, when located adjacent a side wall or partition. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 28781 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory There is not sufficient clear floor space provided to allow an accessible forward approach. Finding 21.00 inches Code At least 30.00 inches ADA 4.19.3, CA 11B-606.2, CA 11B-305 -'elocate the lavatory to provide clear floor space. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,261 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 750 of 853 Record Number 28782 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 28783 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Record Number 28789 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers There is no compliant signage indicating accessibility on the latch side of the entry door of the restroom. Finding None Found ADA 4.30.6, CA 11B-216.8 rovide compliant signage on latch side of door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 751 of 853 Record Number 28788 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers All Gender There is no gender use signage on the entrance door. Finding None Found CA 11B-216.8, CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 28776 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 49.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 °elocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $277 $0.00 Record Number 28777 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 53.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 752 of 853 Record Number 28592 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The height of the operable parts of the seat cover dispenser is greater than the allowed maximum height. Finding 43.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the seat cover dispenser to a compliant height, that rovides sufficient clear floor space, and does not interfere with se of the grab bars. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $277 $0.00 Record Number 28593 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers There are no grab bars. Finding None Found ADA 4.17.6, ADA 4.16.4, CA 11B-604.5 Install the required grab bars in the toilet compartment. tiority Not Set .esolution Not Set 'rogress Not Set .assignment Not Set $267 $0.00 Record Number 28598 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The paper dispenser is located behind the front of toilet seat. Finding See Above ADA 4.2, CA 11B-604.7 emount the toilet paper dispenser so it is within the required stance from the front edge of the toilet seat. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $78 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 753 of 853 Record Number 28595 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The height of the toilet seat is not at the required height. Finding 16.00 inches Code 17.00 - 19.00 inches ADA 4.16.3, CA 11B-604.4 djust or modify the toilet so the seat height is at the required :cessible height. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,707 $0.00 Record Number 28594 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 16.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 28597 Unisex Restroom In Public Works Department Streets & Parks Building Next To Lockers The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 39.00 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 Provide a compliant amount of clearance from the center line of the toilet to the nearest fixture or wall on the wide side. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 754 of 853 Record Number 28478 Visual Alarms (stall visual warning devices integrated with the facility's alarm /stem in all common areas. $2,200 $0.00 There are no visual warning devices at the facility. Finding None Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28468 Break Room A compliant path of travel width is not maintained throughout the break/conference room. Finding None Found ADA 4.27 provide a compliant path of travel width throughout the preak/conference room. riority Not Set esolution Not Set rogress Not Set ..ssignment Not Set $1,840 $0.00 Record Number 28469 Break Room Sink counter height does not meet the standards. Finding 35.75 inches Code Up to 34.00 inches CA 11B-606.3 "rovide compliant sink. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 755 of 853 Record Number 28470 Break Room Sink knee clearance does not meet the standards. Finding 20.00 inches Code At least 27.00 inches ADA 4.27 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 28471 Break Room The toe kick for the sink in break/conference room is not removed. Finding Not Removed CA 11B-606.2, CA 11B-305, CA 11B-306 emove the toe kick for the sink. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $612 $0.00 Record Number 28472 Break Room The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain Ipes under the sink to protect against contact. Make certain sere are no sharp or abrasive surfaces under the sink. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 756 of 853 Record Number 28473 Break Room The cabinet door hardware is not accessible. Finding None Found ADA 4.27, CA 11B-606.4 rovide compliant hardware for the cabinet door. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,000 $0.00 Record Number 28474 Break Room There is not enough clear floor space at the sink. Finding 29.00 inches Code At least 48.00 inches ADA 4.27 rovide enough clear floor space at the location. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Record Number 28475 Break Room There is not enough clear floor space at the sink. Finding 29.50 inches Code At least 30.00 inches ADA 4.27 -ovide enough clear floor space at the location. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $900 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 757 of 853 Record Number 28476 Break Room Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 elocate the dispenser to the correct height. riority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $110 $0.00 Record Number 28477 Break Room Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 55.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7 Relocate the dispenser to the correct height. riority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $110 $0.00 Record Number 28642 Conference Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 Install an International Symbol of Accessibility at the table. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 758 of 853 Record Number 28444 rovide a sufficient number of compliant picnic tables. $500 $0.00 Picnic Table In Public Works Department Streets & Parks Building Picnic Area The required percentage of picnic tables provided are not accessible. Finding None Found Code At least 1.00 tables ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Lockers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 28512 Lockers No accessible lockers were found. Finding Not Available CA 11B-225.2.1, CA 11B-811 rovide a compliant amount of accessible lockers. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $1,840 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Co Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 759 of 853 Record Number 28501 ontact the owner of the vending machines to obtain accessible =nding machines. $0.00 Public Works Department Streets & Parks Building Picnic Area Coca-Cola Vending Machine The forward reach height of the controls on the vending machine is greater than the allowed maximum height. Finding 50.00 inches Code Up to 48.00 inches ADA 4.2.5 riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Record Number 28574 City Vehicle Parking Lot Eye Washing Stations - Eye Washing Station This element is a protruding object. Finding None Found ADA 4.2 "lake sure that the element is not a protruding object. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 760 of 853 Silver Rock Temporary Clubhouse Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44206 Parking Lot The minimum number of accessible parking spaces are not provided in the parking lot. Finding 2.00 spaces Code At least 5.00 spaces ADA 4.1.2(5), CA 11B-208.2 e-stripe any existing parking spaces marked accessible and -eate additional accessible parking spaces. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $370 $0.00 Record Number 44221 Parking Lot Warning Sign The point of contact and telephone number for reclaiming towed vehicles have been left blank. Finding Sign not Filled CA 11B-502.8.2 II in the blank spaces with the point of contact and telephone umber for reclaiming towed vehicles. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $250 $0.00 Record Number 44210 Parking Lot Right Accessible Space The bottom edge of the post -mounted signage designating the accessible parking space is not at the required height. Finding 63.00 inches Code At least 80.00 inches ADA 4.6.4, CA 11B-502.6 post signage at a compliant height. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 761 of 853 Record Number 44209 Parking Lot Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 38.25 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $220 $0.00 Record Number 44207 Parking Lot Right Accessible Space The slope of the accessible parking space is not compliant. Finding 2.60 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 °epave the accessible space to provide a compliant slope. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $3,800 $0.00 Record Number 44208 Parking Lot Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 provide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 762 of 853 Record Number 44212 Parking Lot Left Accessible Space The slope of the accessible parking space is not compliant. Finding 6.80 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 epave the accessible space to provide a compliant slope. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $3,800 $0.00 Record Number 44213 Parking Lot Left Accessible Space There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 istall a wheel stop at the head of the accessible parking space. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 44214 Parking Lot Left Accessible Space The accessible parking space does not meet the minimum requirement for length. Finding 215.50 inches Code At least 216.00 inches CA 11B-502.2 e-stripe the accessible parking space. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $350 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 763 of 853 Record Number 44211 Parking Lot Left Accessible Space The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 e-stripe the existing parking space marked as accessible to fine the width of the space. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $350 $0.00 Record Number 44215 Parking Lot Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 °rovide a minimum fine sign at the parking space below the International Symbol of Accessibility. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $300 $0.00 Record Number 44216 Parking Lot Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 38.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 provide compliant surface identification at the accessible parking Dace. riority Not Set .esolution Not Set 'rogress Not Set _.ssignment Not Set $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 764 of 853 Record Number 44217 Parking Lot Left Accessible Space The bottom edge of the post -mounted signage designating the accessible parking space is not at the required height. Finding 65.50 inches Code At least 80.00 inches ADA 4.6.4, CA 11B-502.6 Dst signage at a compliant height. riority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $158 $0.00 Record Number 44219 Parking Lot Left Accessible Space The slope of the access aisle is not compliant. Finding 3.40 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 Repave the access aisle to provide a compliant surface slope. riority Not Set esolution Not Set 'regress Not Set Assignment Not Set $3,800 $0.00 Record Number 44220 Parking Lot Left Accessible Space The hatched lines are striped a noncompliant distance on center. Finding Not on 36" center CA 11B-502.3.3 e-stripe the hatched lines in a contrasting color at a compliant (stance on center. 'riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $350 $0.00 Passenger Loading Zones Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 765 of 853 Record Number 44154 Valet & Bag Drop There is no required striped access aisle adjacent to the passenger loading zone. Finding None Found ADA 4.6.6, CA 11B-503.3 tripe a compliant access aisle adjacent and parallel to the =hicle pull-up space. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $650 $0.00 Record Number 44153 Valet & Bag Drop There are curbs between the access aisle and the vehicle pull-up space. Finding Curbs Exists ADA 4.6.6, CA 11B-503.4, CA 11B-206.2.1, CA 11B-303.4 rovide compliant curb ramp to provide access from the assenger loading zone. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $150 $0.00 Record Number 44155 Valet & Bag Drop There is no signage designating accessibility posted at the passenger loading zone. Finding None Found ADA 4.1.2(7)(b), ADA 4.6.6 Dst compliant signage designating the passenger loading zone 3 accessible. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $400 $0.00 Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 766 of 853 Record Number 44176 Curb Ramp East Of The Clubhouse The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set _,ssignment Not Set $248 $0.00 Record Number 44177 Curb Ramp East Of The Clubhouse The cross slope is greater than allowed. Finding 4.20 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.7 rovide a compliant curb ramp. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,300 $0.00 Record Number 44178 Curb Ramp East Of The Clubhouse The slope of the curb ramp right side flare is greater than allowed. Finding 11.00 percent Code Up to 10.00 percent ADA 4.7.5, CA 11B-406.2.2 rovide curb ramp side flares with a compliant slope. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 767 of 853 Record Number 44179 Curb Ramp East Of The Clubhouse Top Landing There is not enough top landing clear length. Finding 0.00 inches Code At least 48.00 inches ADA 4.7, CA 11B-406.5.3 rovide a level top landing with enough clear length. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $240 $0.00 Record Number 44268 Curb Ramp From The Accessible Spaces The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set assignment Not Set $248 $0.00 Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44114 Path Of Travel To The Clubhouse Restrooms Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 12.30 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 "rovide a compliant path of travel. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 768 of 853 Record Number 44115 Path Of Travel To The First Hole Exterior Walkway The path of travel is grass, dirt, or gravel, preventing access to individuals with mobility impairments. Finding Dirt, Grass or Gravel ADA 4.5.1, CA 11B-302.1, CA 11B-403.2 rovide an accessible route. riority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $1,840 $0.00 Record Number 44116 Path Of Travel From The Public Right Of Way There is no compliant accessible route from the public right of way to the accessible entrance of the facility. Finding None Found ADA 4.3.2 Provide an accessible route from the public right of way to the --cility. Post compliant directional signage indicating the :cessible route to the facility at every major junction along the accessible route. riority Not Set esolution Not Set 'regress Not Set .,ssignment Not Set $1,840 $0.00 Record Number 44164 Floor Mats Around The Golf Shop & Grill Room 6 Floor Mats The mats or carpet runners do not adhere to the underlying floor surface and slip, thereby creating a hazardous path of travel. Finding Not Accessible ADA 4.5.3, CA 11B-403.2, CA 11B-302 Securely fasten the mats or carpet runners or replace with a iat or carpet runner that grips to the underlying floor surface provide a firm, stable, and slip resistant path of travel. riority Not Set esolution Not Set 'regress Not Set Assignment Not Set $42 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 769 of 853 Record Number 44175 Path Of Travel From The Valet & Bag Drop To The Clubhouse Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 6.50 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. tiority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $3,600 $0.00 Record Number 44182 Path Of Travel From The Storage To The Clubhouse Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 10.20 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 Provide a compliant path of travel. tiority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $3,600 $0.00 Record Number 44183 Path Of Travel From The Storage To The Clubhouse Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 3.60 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 Provide a compliant path of travel. tiority Not Set esolution Not Set 'regress Not Set _assignment Not Set $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 770 of 853 Record Number 44202 Path Of Travel To The Main Entrances Vertical Hazard The vertical clearance height is less than required. Finding 79.25 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-307.4 rovide recommended vertical clearance. riority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $108 $0.00 Record Number 44273 Path Of Travel From Golf Cart Trail To The Driving Range Exterior Walkway The path of travel is grass, dirt, or gravel, preventing access to individuals with mobility impairments. Finding Dirt, Grass or Gravel ADA 4.5.1, CA 11B-302.1, CA 11B-403.2 rovide an accessible route. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,840 $0.00 Record Number 44285 Path Of Travel Near The Outside Dining Area Lights The leading edge of the item protrudes into the circulation route greater than permitted. Finding 14.75 inches Code Up to 4.00 inches ADA 4.4, CA 11B-307.2 Install side extensions, modify, relocate, or lower the item so 'at it is not a protruding object into the circulation route. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $640 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 771 of 853 Record Number 44295 Path Of Travel Around The Valet & Bag Drop Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 9.10 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $3,600 $0.00 Record Number 44296 Path Of Travel Around The Valet & Bag Drop Exterior Walkway There are cross slopes greater than allowed on the primary path of travel. Finding 2.70 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-403.3 Provide a compliant path of travel. riority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $3,600 $0.00 Record Number 44297 Path Of Travel From The Accessible Spaces Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 7.30 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 Provide a compliant path of travel. riority Not Set .esolution Not Set 'regress Not Set _assignment Not Set $3,600 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 772 of 853 Record Number 44247 Path Of Travel To Tee Five Restrooms Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 5.60 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 rovide a compliant path of travel. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $3,600 $0.00 Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44168 Ramp To The Clubhouse Run 1 The slope of the ramp is greater than the allowed slope. Finding 9.20 percent Code Up to 8.33 percent ADA 4.8.2, CA 11B-405.2 Modify the run of the ramp to provide the required slope and cross slope. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $3,600 $0.00 Record Number 44169 Ramp To The Clubhouse Run 1 Top Landing There is a change in elevation greater than allowed on the primary path of travel of the ramp that is not beveled. Finding 0.75 inches Code Up to 0.50 inches ADA 4.3.8, ADA 4.5.2, CA 11B-303, CA 11B-405 Revel the area or resurface the area to provide a smooth and vel path of travel. riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 773 of 853 Record Number 44170 Ramp To The Clubhouse Run 1 Bottom Landing The slope of the landing is greater than required. Finding 6.30 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-405.7.1 odify the landing to create a slope in any direction not Kceeding the required maximum value. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,872 $0.00 Record Number 44171 Ramp To The Clubhouse Run 1 Right Handrail The handrail extension is not parallel to the floor or ground surface. Finding Not Parallel ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,400 $0.00 Record Number 44172 Ramp To The Clubhouse Run 1 Right Handrail There is not enough handrail extension beyond the top or bottom of the rail. Finding 8.00 inches Code At least 12.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,400 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 774 of 853 Record Number 44173 Ramp To The Clubhouse Run 1 Left Handrail The handrail extension is not parallel to the floor or ground surface. Finding Not Parallel ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,400 $0.00 Record Number 44174 Ramp To The Clubhouse Run 1 Left Handrail There is not enough handrail extension beyond the top or bottom of the rail. Finding 5.00 inches Code At least 12.00 inches ADA 4.8.5, CA 11B-405.8, CA 11B-505.10.1 rovide compliant handrail extensions that are parallel to the Dor or ground surface extending the required distance beyond le bottom of the ramp and return smoothly to the post or wall. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,400 $0.00 Record Number 44222 Ramp To The Putting Green Run 1 The width of the ramp is less than required. Finding 47.50 inches Code At least 48.00 inches ADA 4.8.3, CA 11B-405.5 Widen the run of the ramp so that it has minimum required width. riority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $9,515 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 775 of 853 Record Number 44224 Ramp To The Putting Green Run 1 The slope of the ramp is greater than the allowed slope. Finding 8.90 percent Code Up to 8.33 percent ADA 4.8.2, CA 11B-405.2 odify the run of the ramp to provide the required slope and -oss slope. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $3,600 $0.00 Record Number 44223 Ramp To The Putting Green Run 1 The ramp run does not provide adequate edge protection to prevent individuals from slipping off the ramp. Finding None Found ADA 4.8.7, CA 11B-405.9 (stall compliant edge protection on each side of the ramp run. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $470 $0.00 Record Number 44225 Ramp To The Putting Green Run 1 There is only one handrail provided. Finding Missing Handrail ADA 4.8.5, CA 11B-405.8, CA 11B-505.2 Provide a compliant handrail with a compliant distance between le handrail and the adjacent wall. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,200 $0.00 Stairs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 776 of 853 Record Number 44119 Stairs From The Golf Cart Pickup Area To The Clubhouse Run 1 There are no handrails provided on the stairway. Finding None Found ADA 4.9.4, CA 11B-504.6, CA 11B-505.2 rovide compliant handrails. riority Not Set esolution Not Set 'regress Not Set assignment Not Set $1,528 $0.00 Record Number 44120 Stairs From The Golf Cart Pickup Area To The Clubhouse Run 1 There is no detectable striping on each tread of the exterior stairway. Finding None Found ADA 4.9.5, CA 11B-504.4.1 rovide compliant striping to each tread of the stairway. riority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $944 $0.00 Record Number 44266 Stairs From The Storage To The Clubhouse Run 1 There is no detectable striping on each tread of the exterior stairway. Finding None Found ADA 4.9.5, CA 11B-504.4.1 Provide compliant striping to each tread of the stairway. riority Not Set esolution Not Set 'regress Not Set _assignment Not Set $944 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 777 of 853 Record Number 44265 Stairs From The Storage To The Clubhouse Run 1 There are no handrails provided on the stairway. Finding None Found ADA 4.9.4, CA 11B-504.6, CA 11B-505.2 rovide compliant handrails. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $1,528 $0.00 Record Number 44270 Stairs To The Putting Green Run 1 There is no detectable striping on each tread of the exterior stairway. Finding None Found ADA 4.9.5, CA 11B-504.4.1 rovide compliant striping to each tread of the stairway. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $944 $0.00 Record Number 44271 Stairs To The Putting Green Run 1 Left Handrail The top handrail extension is not the required length beyond the top riser. Finding 10.50 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 Install a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. 'riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 778 of 853 Record Number 44272 Stairs To The Putting Green Run 1 Right Handrail The top handrail extension is not the required length beyond the top riser. Finding 4.00 inches Code At least 12.00 inches ADA 4.9.4(2), CA 11B-505.10.2 (stall a compliant handrail extension to the top of the handrail 'at extends beyond the top riser and is parallel to the floor arface of the landing. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $800 $0.00 Record Number 44287 Stairs To The Golf Cart Pickup Area Run 1 There is no detectable striping on each tread of the exterior stairway. Finding None Found ADA 4.9.5, CA 11B-504.4.1 Provide compliant striping to each tread of the stairway. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $944 $0.00 Record Number 44288 Stairs To The Golf Cart Pickup Area Run 1 Right Handrail There are no bottom handrail extensions provided. Finding None Found ADA 4.9.4(2), CA 11B-505.10.3 Install handrail extension to the bottom of the handrail that Ktends beyond the bottom riser at least one tread depth. tiority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $1,425 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 779 of 853 Record Number 44289 Stairs To The Golf Cart Pickup Area Run 1 Middle Handrail The handrail extension is not parallel with the floor surface at the bottom landing. Finding Not Parallel ADA 4.9.4(2), CA 11B-505.10.3 (stall a compliant extension to the handrail. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $627 $0.00 Record Number 44290 Stairs To The Golf Cart Pickup Area Run 1 Left Handrail There are no bottom handrail extensions provided. Finding None Found ADA 4.9.4(2), CA 11B-505.10.3 Install handrail extension to the bottom of the handrail that xtends beyond the bottom riser at least one tread depth. 'riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,425 $0.00 Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44264 Womens Clubhouse Restroom Push / Pull The door opening force for this door is greater than allowed. Finding 12.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force quirements. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 780 of 853 Record Number 44299 Mens Clubhouse Restroom Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44113 Open Doorway To The Golf Shop The vertical clearance height of the open doorway is not compliant. Finding 78.25 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $5,600 $0.00 Record Number 44122 Golf Shop Main Entrance The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 781 of 853 Record Number 44121 Golf Shop Main Entrance Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44205 Exterior Door Near Golf Shop Check Out Counter The height of the threshold at the sliding door is not compliant. Finding 1.25 inches Code Up to 0.75 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide a compliant ireshold. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $310 $0.00 Record Number 44229 Golf Shop Office (Exterior Door) The clear opening width of the door is less than required. Finding 31.00 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $1,750 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 782 of 853 Record Number 44232 Golf Shop Office (Exterior Door) Push Side There is no level landing at this door. Finding 2.40 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set esolution Not Set 'rogress Not Set assignment Not Set $1,500 $0.00 Record Number 44231 Golf Shop Office (Exterior Door) The height of the threshold at the entrance door is greater than allowed. Finding 0.62 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Record Number 44230 Golf Shop Office (Exterior Door) Lever The door opening force for this door is greater than allowed. Finding 14.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. 'riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set ,25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 783 of 853 Record Number 44259 Golf Shop Office (Interior Door) The door closing device limits the required headroom clearance. Finding 77.87 inches Code At least 80.00 inches ADA 4.4.2, CA 11B-404.2.3 eplace the door closing device with a device that fits above the Dor casing and provides a compliant clearance height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $250 $0.00 Record Number 44142 Grill Room Kitchen (East Entrance) Push Side There is less than the required latch side clearance on the push side of the door. Finding 11.50 inches Code At least 12.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance on the push side F the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 44141 Grill Room Kitchen (East Entrance) The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 784 of 853 Record Number 44140 Grill Room Kitchen (East Entrance) Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44152 Open Doorway From The Snack Bar To The Kitchen The vertical clearance height of the open doorway is not compliant. Finding 79.25 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $5,600 $0.00 Record Number 44167 Grill Room Main Entrance The height of the threshold at the entrance door is greater than allowed. Finding 0.75 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 785 of 853 Record Number 44166 Grill Room Main Entrance Push / Pull The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44249 Grill Room Kitchen (West Entrance) Pull Side There is less than the required latch side clearance on the pull side of the door. Finding 11.50 inches Code At least 24.00 inches ADA 4.13.6, CA 11B-404.2.4.1 rovide the recommended latch side clearance for the door. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,921 $0.00 Record Number 44250 Grill Room Kitchen (West Entrance) Pull Side There is no level landing at this door. Finding 7.40 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 786 of 853 Record Number 44248 Grill Room Kitchen (West Entrance) Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44258 Grill Room (North Entrance) Pull Side There is no level landing at this door. Finding 8.40 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 44257 Grill Room (North Entrance) The height of the threshold at the entrance door is greater than allowed. Finding 0.87 inches Code Up to 0.50 inches ADA 4.13.8, CA 11B-404.2.5 odify or replace the threshold to provide the recommended eight. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $436 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 787 of 853 Record Number 44256 Grill Room (North Entrance) Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44292 Open Doorway To The Snack Bar The vertical clearance height of the open doorway is not compliant. Finding 78.37 inches Code At least 80.00 inches ADA 4.13.5 rovide a compliant open doorway at the location. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $5,600 $0.00 Record Number 44246 Womens Restroom Near Hole 14 Push Side There is no level landing at this door. Finding 2.70 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 788 of 853 Record Number 44245 Womens Restroom Near Hole 14 Push / Pull The door opening force for this door is greater than allowed. Finding 15.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44263 Mens Restroom Near Hole 14 Push Side There is no level landing at this door. Finding 2.80 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 44262 Mens Restroom Near Hole 14 Push / Pull The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 789 of 853 Record Number 44112 Mens Restroom Near Tee Five Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44118 Womens Restroom Near Tee Five Push / Pull The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Counters Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44269 Golf Shop Check Out Counter The height of the counter or desk does not comply with height requirements. Finding 47.87 inches Code 28.00 - 34.00 inches ADA 4.32.4, ADA 7.2, ADA 904.4, CA 11B-904.4 "rovide a portion of counter at the compliant height. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $3,500 $0.00 Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 790 of 853 Record Number 44193 Golf Shop Managers Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 44203 Golf Shop Main Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 (stall accessible room signage. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 44298 Golf Shop Office There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 791 of 853 Record Number 44184 Room Identification Signage There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 44204 Grill Room (South Entrance) There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 44291 Grill Room Main Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 install accessible room signage. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 ATMs Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 792 of 853 Record Number 44233 Grill Room ATM Keypad does not contain braille. Finding See Above Code None Found ADA 4.34.3 TM Keypad must contain braille on it. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44137 Womens Clubhouse Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Insulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Jrasive surfaces under the lavatory. Priority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Record Number 44138 Womens Clubhouse Restroom Female The gender use signage on the entrance door is not mounted at the required height. Finding 53.75 inches Code 60.00 inches CA 11B-703.7.2.6 -'ost gender use signage on the center of the door at the quired height. tiority Not Set esolution Not Set 'rogress Not Set assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 793 of 853 Record Number 44139 Womens Clubhouse Restroom Female The signage does not have contrasting finish from the door. Finding See Above CA 11B-703.7.2.6 estroom door signage should have contrasting finish. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $170 $0.00 Record Number 44201 Mens Clubhouse Restroom The signage is not mounted at the required height. Finding 60.50 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 3st compliant signage at the restroom. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Record Number 44199 Mens Clubhouse Restroom Male The gender use signage on the entrance door is not mounted at the required height. Finding 59.87 inches Code 60.00 inches CA 11B-703.7.2.6 3st gender use signage on the center of the door at the ?quired height. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 794 of 853 Record Number 44200 Mens Clubhouse Restroom Male The signage does not have contrasting finish from the door. Finding See Above CA 11B-703.7.2.6 estroom door signage should have contrasting finish. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $170 $0.00 Record Number 44195 Mens Clubhouse Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.87 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required Dron height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,500 $0.00 Record Number 44196 Mens Clubhouse Restroom Lavatory The knee clearance space under the lavatory is less than the required minimum height. Finding 26.50 inches Code At least 27.00 inches CA 11B-606.2, CA 11B-306.3.1 aise or replace the lavatory to provide the minimum required lee clearance. riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 795 of 853 Record Number 44197 Mens Clubhouse Restroom Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 44198 Mens Clubhouse Restroom Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 )sulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 44234 Womens Clubhouse Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 Relocate the toilet so the distance from the center line of the toilet to the nearest side wall meets the required distance. riority Not Set .esolution Not Set 'rogress Not Set ..ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 796 of 853 Record Number 44236 Womens Clubhouse Restroom The toilet paper dispenser is located above the provided grab bar. Finding Above Grab Bar Code Relocate Dispenser ADA 4.16.6, CA 11B-604.7 emount the dispenser below the grab bar at 19" minimum. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Record Number 44282 Mens Clubhouse Restroom The length of the rear grab bar is less than required. Finding 35.00 inches Code At least 36.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.2 eplace the rear grab bar with a compliant grab bar. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $267 $0.00 Record Number 44283 Mens Clubhouse Restroom The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 18.00 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 797 of 853 Record Number 44284 Mens Clubhouse Restroom The toilet paper dispenser is located above the provided grab bar. Finding Above Grab Bar Code Relocate Dispenser ADA 4.16.6, CA 11B-604.7 emount the dispenser below the grab bar at 19" minimum. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $277 $0.00 Record Number 44279 Mens Clubhouse Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 44281 Mens Clubhouse Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.62 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 798 of 853 Record Number 44125 Womens Restroom Near Hole 14 Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 44126 Womens Restroom Near Hole 14 Female The signage does not have contrasting finish from the door. Finding See Above CA 11B-703.7.2.6 estroom door signage should have contrasting finish. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $170 $0.00 Record Number 44127 Womens Restroom Near Hole 14 Braille is not located immediately below the raised letters. Finding None Found ADA 4.30.4, CA 11B-703.3.2 ake sure that braille is located immediately below the raised tters. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 799 of 853 Record Number 44124 Womens Restroom Near Hole 14 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 44133 Mens Restroom Near Hole 14 The height of the urinal rim in the restroom is not compliant. Finding 22.25 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 Lower the urinal designated to be accessible in the restroom so 'iat the rim height is compliant. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,397 $0.00 Record Number 44134 Mens Restroom Near Hole 14 Male The gender use signage on the entrance door is not mounted at the required height. Finding 60.25 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 800 of 853 Record Number 44135 Mens Restroom Near Hole 14 Male The signage does not have contrasting finish from the door. Finding See Above CA 11B-703.7.2.6 estroom door signage should have contrasting finish. riority Not Set .esolution Not Set rogress Not Set assignment Not Set $170 $0.00 Record Number 44132 Mens Restroom Near Hole 14 Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 44163 Mens Restroom Near Hole 14 Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 Provide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $269 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 801 of 853 Record Number 44162 Mens Restroom Near Hole 14 The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 41.75 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 44160 Mens Restroom Near Hole 14 The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.50 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 44255 Womens Restroom Near Hole 14 Feminine products disposal distance from front of the toilet is not compliant. Finding 16.00 inches Code Up to 12.00 inches rovide feminine products disposal at the required distance om front of the toilet. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 802 of 853 Record Number 44254 Womens Restroom Near Hole 14 Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $269 $0.00 Record Number 44252 Womens Restroom Near Hole 14 The height of the side grab bar is not at the correct height. Finding 32.75 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Record Number 44253 Womens Restroom Near Hole 14 The grab bar on the rear wall is not at the correct height. Finding 32.75 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 803 of 853 Record Number 44150 Mens Restroom Near Tee Five Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $269 $0.00 Record Number 44148 Mens Restroom Near Tee Five The height of the side grab bar is not at the correct height. Finding 34.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Record Number 44149 Mens Restroom Near Tee Five The grab bar on the rear wall is not at the correct height. Finding 34.50 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 804 of 853 Record Number 44146 Mens Restroom Near Tee Five The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.87 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Not Set .esolution Not Set 'regress Not Set Assignment Not Set $2,500 $0.00 Record Number 44151 Mens Restroom Near Tee Five The toilet paper dispenser is not mounted at the required height. Finding 18.12 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Not Set .esolution Not Set 'regress Not Set .ssignment Not Set $277 $0.00 Record Number 44190 Mens Restroom Near Tee Five The height of the urinal rim in the restroom is not compliant. Finding 22.50 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 )wer the urinal designated to be accessible in the restroom so 'at the rim height is compliant. tiority Not Set .esolution Not Set 'regress Not Set .,ssignment Not Set 41,397 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 805 of 853 Record Number 44191 Mens Restroom Near Tee Five The height of the urinal flush control in the restroom is greater than the required maximum height. Finding 44.12 inches Code Up to 44.00 inches ADA 4.18.4, CA 11B-605.4 )wer the flush control valve on the urinal to a height not reater than the required maximum height. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $227 $0.00 Record Number 44187 Mens Restroom Near Tee Five Lavatory The height of the counter surface is greater than allowed. Finding 34.25 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,286 $0.00 Record Number 44188 Mens Restroom Near Tee Five Lavatory The pipes under the lavatory do not provide protection against contact. Finding Pipes not wrapped. ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 806 of 853 Record Number 44189 Mens Restroom Near Tee Five Lavatory The supply lines under the lavatory do not provide protection against contact. Finding Not Wrapped ADA 4.19.4, CA 11B-606.5 Isulate or otherwise configure pipes under the lavatory to rotect against contact. Make certain there are no sharp or Drasive surfaces under the lavatory. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $149 $0.00 Record Number 44192 Mens Restroom Near Tee Five Male The signage does not have contrasting finish from the door. Finding See Above CA 11B-703.7.2.6 estroom door signage should have contrasting finish. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $170 $0.00 Record Number 44186 Mens Restroom Near Tee Five Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 807 of 853 Record Number 44242 Womens Restroom Near Tee Five Feminine products disposal distance from front of the toilet is not compliant. Finding 17.50 inches Code Up to 12.00 inches rovide feminine products disposal at the required distance om front of the toilet. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Record Number 44241 Womens Restroom Near Tee Five Door does not close automatically. Finding Missing Hardware ADA A4.17.5, CA 11B-604.8.1.2 rovide an automatic door closer, spring hinge, pull bar or :cessible handle mounted on the inside of the compartment Dor to the compartment designated to be accessible. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $269 $0.00 Record Number 44239 Womens Restroom Near Tee Five The height of the side grab bar is not at the correct height. Finding 35.00 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 808 of 853 Record Number 44240 Womens Restroom Near Tee Five The grab bar on the rear wall is not at the correct height. Finding 35.00 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Not Set esolution Not Set 'regress Not Set Assignment Not Set $231 $0.00 Record Number 44243 Womens Restroom Near Tee Five The toilet paper dispenser is not mounted at the required height. Finding 18.12 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. riority Not Set esolution Not Set 'regress Not Set .ssignment Not Set $277 $0.00 Record Number 44237 Womens Restroom Near Tee Five The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 18.75 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. riority Not Set esolution Not Set 'regress Not Set Assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 809 of 853 Record Number 44277 Womens Restroom Near Tee Five Female The restroom signage is not compliant. Finding None Found CA 11B-703.7.2.6.2 rovide compliant restroom signage. riority Not Set esolution Not Set rogress Not Set assignment Not Set $158 $0.00 Record Number 44278 Womens Restroom Near Tee Five Female The signage does not have contrasting finish from the door. Finding See Above CA 11B-703.7.2.6 estroom door signage should have contrasting finish. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $170 $0.00 Record Number 44276 Womens Restroom Near Tee Five Lavatory The height of the counter surface is greater than allowed. Finding 34.25 inches Code Up to 34.00 inches ADA 4.19.2, CA 11B-213, CA 11B-606.3 elocate or replace the lavatory to provide a maximum counter arface height of no greater than recommended. 'riority Not Set esolution Not Set 'rogress Not Set .ssignment Not Set $1,286 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 810 of 853 Record Number 44275 Womens Restroom Near Tee Five Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 42.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $277 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44157 Drinking Fountain Near Hole 14 The spout outlet height is greater than required. Finding 36.25 inches Code Up to 36.00 inches ADA 4.15.2, CA 11B-602.4 provide a spout outlet that does not exceed the required height. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $627 $0.00 Record Number 44158 Drinking Fountain Near Hole 14 The height of the water stream is less than required. Finding 1.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 ^,djust the flow of the water stream to a compliant height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 811 of 853 Record Number 44156 Drinking Fountain Near Hole 14 The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $2,500 $0.00 Record Number 44159 Drinking Fountain Near Hole 14 The clear floor space slope is not compliant. Finding 3.80 percent Code Up to 2.00 percent ADA 4.15.5, CA 11B-602.2 rovide compliant clear floor space at the drinking fountain. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,200 $0.00 Record Number 44227 Drinking Fountain At The Tee Five Restrooms The spout outlet height is greater than required. Finding 36.75 inches Code Up to 36.00 inches ADA 4.15.2, CA 11B-602.4 rovide a spout outlet that does not exceed the required height. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $627 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 812 of 853 Record Number 44228 Drinking Fountain At The Tee Five Restrooms The height of the water stream is less than required. Finding 1.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 djust the flow of the water stream to a compliant height. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 44226 Drinking Fountain At The Tee Five Restrooms The provided drinking fountain is not a High/Low fountain. Finding Fountain Not Compliant ADA 4.2.4.2, CA 11B-211.2, CA 11B-602 eplace the drinking fountain with a compliant High/Low )untain. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $2,500 $0.00 Food Service Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44181 Outside Dinning Area The required minimum percentage of accessible tables and seating is not provided. Finding None Found Code At least 4.00 tables ADA 4.32, ADA 7.2 modify or replace one or more of the tables in the food service -ea to meet the required minimum accessible seating. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 813 of 853 Record Number 44267 Inside Dining Area odify or replace one or more of the tables in the food service -ea to meet the required minimum accessible seating. $2,500 $0.00 The required minimum percentage of accessible tables and seating is not provided. Finding None Found Code At least 2.00 tables ADA 4.32, ADA 7.2 °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44136 Womens Clubhouse Restroom There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 Tnstall visual warning devices integrated with the facility's alarm istem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Not Set esolution Not Set rogress Not Set ..ssignment Not Set $2,200 $0.00 Record Number 44194 Mens Clubhouse Restroom There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 Tnstall visual warning devices integrated with the facility's alarm istem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Not Set esolution Not Set rogress Not Set ,assignment Not Set $2,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 814 of 853 Record Number 44165 Visual Alarm There are some visual warning devices, though visual warning devices are not located throughout the facility. Finding Some Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, classrooms and eneral use rooms, accessible restrooms and other accessible )oms. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,200 $0.00 Record Number 44180 Outside Dinning Area There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, ADA 7.2, ADA 215.2, CA 11B-215.2, CA 11B-907.5.2.3. 1 Install visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,200 $0.00 Record Number 44123 Womens Restroom Near Hole 14 There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 Install visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. tiority Not Set .esolution Not Set 'regress Not Set ,ssignment Not Set $2,200 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 815 of 853 Record Number 44131 Mens Restroom Near Hole 14 There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,200 $0.00 Record Number 44185 Mens Restroom Near Tee Five There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,200 $0.00 Record Number 44274 Womens Restroom Near Tee Five There are no visual warning devices in this area of the facility. Finding None Found ADA 4.28, CA 11B-215.2, CA 11B-907.5.2.3.1 (stall visual warning devices integrated with the facility's alarm /stem in all common areas such as hallways, general use )oms, and in accessible restrooms and other accessible rooms. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,200 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 816 of 853 Record Number 44143 Snack Bar The pipes are not wrapped for the sink. Finding Not Wrapped ADA 4.27, CA 11B-606.5 Isulate or Otherwise configure pipes under the sink to protect aainst contact. Make certain there are no sharp or abrasive arfaces under the sink. °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $149 $0.00 Record Number 44144 Snack Bar Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.25 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set 'regress Not Set .ssignment Not Set $180 $0.00 Record Number 44145 Snack Bar Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 45.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 Relocate the dispenser to the correct height. riority Not Set .esolution Not Set 'regress Not Set _assignment Not Set $180 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 817 of 853 Record Number 44303 Employee Time Clock In Golf Shop Time Clock - Other The highest point of operation for the element is not compliant. Finding 62.75 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $50 $0.00 Record Number 44286 Grill Room Kitchen First Aid Kit First Aid Kit - Other The highest point of operation for the element is not compliant. Finding 65.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $50 $0.00 Record Number 44293 Water Refilling Station Near Hole 14 Water Refilling Station - Other The clear floor space width is not compliant. Finding 29.25 inches Code At least 30.00 inches ADA 4.2, CA 11B-305 Provide compliant clear floor space. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 818 of 853 Record Number 44294 rovide compliant clear floor space. $500 $0.00 Water Refilling Station Near Hole 14 Water Refilling Station - Other The clear floor space slope is not compliant. Finding 4.60 percent Code Up to 2.00 percent ADA 4.2, CA 11B-305.2 riority Not Set .esolution Not Set rogress Not Set assignment Not Set Benches Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44128 Benches Near Driving Range There are not enough accessible benches at the location with respect to the number of benches available. Finding None Found Code At least 1.00 benches ADA 5.8, ADA A4.2.6 provide compliant accessible benches at the location. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $800 $0.00 Record Number 44129 Benches Near Driving Range The bench height is not compliant. Finding 16.50 inches Code 17.00 - 19.00 inches ADA 5.8, ADA A4.2.6 Adjust the bench height to recommended value. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 819 of 853 Record Number 44130 Benches Near Driving Range The bench is not on an accessible route. Finding Not Accessible ADA 5.8, ADA A4.2.6 rovide a compliant accessible route to the benches. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,840 $0.00 Fitting/Dressing Rooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44300 Golf Shop Dressing Room There is not enough turning space to accommodate a wheelchair. Finding 31.00 inches Code At least 60.00 inches ADA 4.35.2 rovide compliant turning space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,260 $0.00 Record Number 44301 Golf Shop Dressing Room The mirror width is not compliant. Finding 11.50 inches Code At least 18.00 inches ADA 4.35.5 "rovide a compliant mirror in the fitting/dressing room. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $450 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 820 of 853 Record Number 44302 Golf Shop Dressing Room )wer the mirror so the bottom edge of the reflective surface is D higher than recommended above the finished floor. $277 $0.00 The bottom edge of the reflective surface of the mirror is not at the correct height. Finding 23.25 inches Code Up to 20.00 inches ADA 4.35.5 °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 821 of 853 Silverrock Maintenance Building Parking Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44311 Accessible Parking There is no warning signage posted regarding unauthorized use of accessible parking spaces in the parking lot. Finding None Found CA 11B-502.8 rovide compliant signage regarding unauthorized use of :cessible parking spaces. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $250 $0.00 Record Number 44310 Accessible Parking There is no device at the head of the general parking spaces to prevent vehicles from encroaching into walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 )stall a wheel stop at the head of the general parking spaces. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $240 $0.00 Record Number 44316 Accessible Parking Right Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 37.50 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Dace. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $220 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 822 of 853 Record Number 44312 Accessible Parking Right Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 98.50 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Not Set esolution Not Set 'regress Not Set ,ssignment Not Set $350 $0.00 Record Number 44313 Accessible Parking Right Accessible Space The slope of the accessible parking space is not compliant. Finding 2.50 percent Code Up to 2.00 percent ADA 4.6.3, CA 11B-502.4 Repave the accessible space to provide a compliant slope. riority Not Set esolution Not Set 'regress Not Set Assignment Not Set $3,800 $0.00 Record Number 44314 Accessible Parking Right Accessible Space There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 install a wheel stop at the head of the accessible parking space. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 823 of 853 Record Number 44315 Accessible Parking Right Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the Iternational Symbol of Accessibility. riority Not Set esolution Not Set 'rogress Not Set ,ssignment Not Set $300 $0.00 Record Number 44318 Accessible Parking Left Accessible Space The accessible parking space does not meet the minimum requirements for width. Finding 107.00 inches Code At least 108.00 inches ADA 4.6.3, CA 11B-502 e-stripe the accessible parking space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $350 $0.00 Record Number 44319 Accessible Parking Left Accessible Space There is no device at the head of the accessible parking space to prevent vehicles from encroaching into accessible aisles or walkways. Finding None Found ADA 4.6.3, CA 11B-502.7.2 Install a wheel stop at the head of the accessible parking space. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 824 of 853 Record Number 44320 Accessible Parking Left Accessible Space There is no signage posted at the accessible parking space showing the International Symbol of Accessibility. Finding None Found ADA 4.6.4, CA 11B-502.6, CA 11B-703.7.2.1 rovide compliant sigange at the accessible space. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $250 $0.00 Record Number 44317 Accessible Parking Left Accessible Space The accessible parking space outline is faded, damaged, missing or otherwise not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.2 Re -stripe the existing parking space marked as accessible to 'efine the width of the space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $350 $0.00 Record Number 44321 Accessible Parking Left Accessible Space There is no minimum fine sign at the parking space. CA 11B-502.6.2 rovide a minimum fine sign at the parking space below the )ternational Symbol of Accessibility. 'riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 825 of 853 Record Number 44323 Accessible Parking Left Accessible Space The surface identification at the designated accessible parking space is not compliant. Finding 37.00 inches Code 36.00 inches ADA 4.6.4, CA 11B-502.6.4 rovide compliant surface identification at the accessible parking Jace. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $220 $0.00 Record Number 44322 Accessible Parking Left Accessible Space ISA surface identification is faded and not viewable. Finding Faded or Damaged ADA 4.6.4, CA 11B-502.6.4 °epaint the ISA surface identification in the parking space. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $117 $0.00 Record Number 44324 Accessible Parking Left Accessible Space The access aisle at the parking space is not outlined in blue. Finding Not Outlined in blue CA 11B-502.3.4 ''utline the access aisle in blue color. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 826 of 853 Record Number 44325 e-stripe the hatched lines in a contrasting color at a compliant (stance on center. $350 $0.00 Accessible Parking Left Accessible Space The hatched lines are striped a noncompliant distance on center. Finding Not on 36" center CA 11B-502.3.3 riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set Curb Ramps Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44304 1st Curb Ramp From The Public Right Of Way The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 provide compliant detectable warnings to surface. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $248 $0.00 Record Number 44305 1st Curb Ramp From The Public Right Of Way The running slope is greater than allowed. Finding 8.70 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 ^rovide a compliant curb ramp. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $1,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 827 of 853 Record Number 44306 1st Curb Ramp From The Public Right Of Way Top Landing The slope at the top landing is greater than allowed. Finding 2.40 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.3 rovide a top landing that has a compliant slope and ianeuvering space. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,260 $0.00 Record Number 44328 Right Curb Ramp From The Accessible Spaces The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set ,assignment Not Set $248 $0.00 Record Number 44346 2nd Curb Ramp From The Public Right Of Way The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 Provide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $248 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 828 of 853 Record Number 44347 2nd Curb Ramp From The Public Right Of Way The width of the curb ramp is less than required. Finding 47.00 inches Code At least 48.00 inches ADA 4.7.3, CA 11B-406.5.2 rovide a compliant curb ramp. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,300 $0.00 Record Number 44369 Left Curb Ramp From The Accessible Spaces The curb ramp does not provide a detectable warning surface which includes truncated domes. ADA 4.7.7, CA 11B-406.5.12 rovide compliant detectable warnings to surface. riority Not Set esolution Not Set rogress Not Set ,assignment Not Set $248 $0.00 Record Number 44370 Left Curb Ramp From The Accessible Spaces The running slope is greater than allowed. Finding 8.50 percent Code Up to 8.33 percent ADA 4.7.2, CA 11B-406.2.2 Provide a compliant curb ramp. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,300 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 829 of 853 Record Number 44371 rovide a top landing that has a compliant slope and ianeuvering space. $1,260 $0.00 Left Curb Ramp From The Accessible Spaces Top Landing The slope at the top landing is greater than allowed. Finding 2.60 percent Code Up to 2.00 percent ADA 4.3.7, CA 11B-406.5.3 riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set Path of Travel Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44307 Path Of Travel From The Public Right Of Way Exterior Walkway There are slopes greater than allowed maximum slope on the primary path of travel. Finding 6.60 percent Code Up to 5.00 percent ADA 4.3.7, CA 11B-403.3, CA 11B-402 provide a compliant path of travel. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $3,600 $0.00 Record Number 44343 Continuing Path Of Travel From The Public Right Of Way Path Of Travel Crosses Traffic There are no detectable warnings where the pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29, CA 11B-705.1.2.5, CA 11B-247.1.2.5 rovide detectable warnings. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $190 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 830 of 853 Record Number 44344 rovide a compliant crosswalk. $1,100 $0.00 Continuing Path Of Travel From The Public Right Of Way Path Of Travel Crosses Traffic The pedestrian route crosses vehicular traffic. Finding None Found ADA 4.29 riority Not Set .esolution Not Set rogress Not Set assignment Not Set Doors Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44335 Gate Near The Accessible Spaces The clear opening width of the door is less than required. Finding 25.50 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 Widen the door opening and install a door that provides at least ie minimum clear width with the door open 90 degrees. Priority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,750 $0.00 Record Number 44348 Main Entrance Lever The door opening force for this door is greater than allowed. Finding 10.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 Adjust the closer on the door to meet the door opening force quirements. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 831 of 853 Record Number 44361 Gate From The Public Right 0f Way The clear opening width of the door is less than required. Finding 25.75 inches Code At least 32.00 inches ADA 4.13.5, CA 11B-404.2.3 liden the door opening and install a door that provides at least le minimum clear width with the door open 90 degrees. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,750 $0.00 Record Number 44362 Gate From The Public Right 0f Way Push Side There is no level landing at this door. Finding 3.30 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 rovide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 44363 Gate From The Public Right 0f Way Pull Side There is no level landing at this door. Finding 4.00 percent Code Up to 2.00 percent ADA 4.13.6, CA 11B-404.2.4.4 Provide a level landing. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 832 of 853 Record Number 44309 Door From The Locker Room To The Garage Pull Side There is not enough clear floor space provided at the pull side of the door. Finding 59.00 inches Code At least 60.00 inches ADA 4.13.6, CA 11B-404.2.4 rovide the recommended clear floor space on the pull side of le door. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,921 $0.00 Record Number 44308 Door From The Locker Room To The Garage Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 '\djust the closer on the door to meet the door opening force quirements. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $25 $0.00 Record Number 44331 Womens Restroom Lever The door opening force for this door is greater than allowed. Finding 6.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 "djust the closer on the door to meet the door opening force quirements. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 833 of 853 Record Number 44355 Door From Staff Lounge To The Locker Room Lever The door opening force for this door is greater than allowed. Finding 9.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44360 Mens Restroom Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $25 $0.00 Record Number 44391 Door From The Reception Area To The Break Room Lever The door opening force for this door is greater than allowed. Finding 7.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 djust the closer on the door to meet the door opening force ?quirements. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $25 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 834 of 853 Record Number 44392 djust the closer on the door to meet the door opening force ?quirements. $25 $0.00 Door From Staff Lounge To Garage Lever The door opening force for this door is greater than allowed. Finding 8.00 pounds Code Up to 5.00 pounds CA 11B-404.2.9 riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set Signage Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44330 Main Entrance There is no room signage. Finding None Found ADA 4.30, CA 11B-216.2, CA 11B-216.6 Tnstall accessible room signage. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $158 $0.00 Record Number 44372 Directional Signage From Public Right Of Way There is no directional signage. Finding None Found ADA 4.30, CA 11B-216.3, CA 11B-703.5 Install directional signage to each accessible element or room. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 835 of 853 Record Number 44381 Room Identification Signage There is no compliant room identification signage provided. Finding None Found ADA 4.30, CA 11B-216.2 (stall compliant room identification signage. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $158 $0.00 Restrooms Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44333 Womens Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.75 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 Raise or replace the lavatory to provide the minimum required apron height. tiority Not Set .esolution Not Set 'rogress Not Set ssignment Not Set $2,500 $0.00 Record Number 44334 Womens Restroom The signage is not mounted at the required height. Finding 60.12 inches on center Code 60.00 inches on center ADA 4.30.6, CBC 2013 11B-703.2.6 Post compliant signage at the restroom. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 836 of 853 Record Number 44332 Womens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 52.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. tiority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $277 $0.00 Record Number 44358 Mens Restroom The height of the urinal rim in the restroom is not compliant. Finding 17.75 inches Code Up to 17.00 inches ADA 4.18.2, CA 11B-605.2 Lower the urinal designated to be accessible in the restroom so 'iat the rim height is compliant. tiority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $1,397 $0.00 Record Number 44357 Mens Restroom Lavatory The apron height under the lavatory is less than the required minimum height. Finding 28.87 inches Code At least 29.00 inches CA 11B-306.3.3, CA 11B-606.2 aise or replace the lavatory to provide the minimum required Dron height. Priority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 837 of 853 Record Number 44359 Mens Restroom Male The gender use signage on the entrance door is not mounted at the required height. Finding 59.62 inches Code 60.00 inches CA 11B-703.7.2.6 Dst gender use signage on the center of the door at the ?quired height. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $158 $0.00 Record Number 44356 Mens Restroom Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 53.00 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 °elocate the dispenser to the correct height. Priority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Record Number 44379 Womens Restroom Feminine products disposal distance from front of the toilet is not compliant. Finding 21.50 inches Code Up to 12.00 inches provide feminine products disposal at the required distance om front of the toilet. tiority Not Set .esolution Not Set 'rogress Not Set assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 838 of 853 Record Number 44377 Womens Restroom The height of the side grab bar is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Record Number 44375 Womens Restroom The distance between the wall and the gripping surface of the grab bar does not meet requirements. Finding 1.25 inches Code At least 1.50 inches ADA 4.26.2, ADA A4.26.1, CA 11B-604.5, CA 11B-609.3 rovide a grab bar that has a compliant gripping surface meets I other requirements. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $250 $0.00 Record Number 44376 Womens Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 53.75 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 839 of 853 Record Number 44378 Womens Restroom The grab bar on the rear wall is not at the correct height. Finding 33.75 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Record Number 44373 Womens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. tiority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 44380 Womens Restroom The toilet paper dispenser is not mounted at the required height. Finding 17.75 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. tiority Not Set .esolution Not Set 'rogress Not Set .,ssignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 840 of 853 Record Number 44388 Mens Restroom The coat hook is not mounted at the correct height. Finding 48.25 inches Code 36.00 - 48.00 inches ADA 4.2.5, CA 11B-308, CA 11B-603.4, CA 11B-604.8.3 ount the coat hook at the recommended height. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $50 $0.00 Record Number 44385 Mens Restroom The distance from the back wall to the front of the grab bar is less than required. Finding 53.25 inches Code At least 54.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-604.5.1, CA 11B-609 (stall or move the grab bar to create the required distance om the back wall to the front of the grab bar. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $267 $0.00 Record Number 44387 Mens Restroom The grab bar on the rear wall is not at the correct height. Finding 33.50 inches Code 33.00 inches ADA 4.17.6, CA 11B-609.4 emount the rear grab bar in the compartment designated to e accessible so the height of the gripping surface is at the )rrect height. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $231 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 841 of 853 Record Number 44386 Mens Restroom The height of the side grab bar is not at the correct height. Finding 33.12 inches Code 33.00 inches ADA 4.17.6, ADA 4.16.4, CA 11B-609.4, CA 11B-604.5 emount the grab bar so it is at the correct height. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $500 $0.00 Record Number 44389 Mens Restroom The toilet paper dispenser is not mounted at the required height. Finding 18.00 inches Code At least 19.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser in the compartment to the ?quired height. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $277 $0.00 Record Number 44390 Mens Restroom The location of the toilet paper dispenser is not within the required distance from the front edge of the toilet seat. Finding 17.50 inches Code Up to 12.00 inches ADA 4.16.6, CA 11B-604.7, CA 11B-309.4 emount the toilet paper dispenser at a compliant height and cation. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $277 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 842 of 853 Record Number 44382 Mens Restroom The distance from the center of the toilet to the nearest side wall does not meet the required distance. Finding 19.12 inches on center Code 18.00 inches on center ADA 4.16.2, CA 11B-604.2 elocate the toilet so the distance from the center line of the )ilet to the nearest side wall meets the required distance. °riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Record Number 44384 Mens Restroom The toilet does not provide the required distance from the center line to a fixture or wall on the wide side. Finding 40.87 inches Code At least 42.00 inches ADA 4.17.3, CA 11B-604 rovide a compliant amount of clearance from the center line of le toilet to the nearest fixture or wall on the wide side. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $2,500 $0.00 Drinking Fountains Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44326 Drinking Fountain In Maintenance The height of the water stream is less than required. Finding 1.00 inches Code At least 4.00 inches ADA 4.15.3, CA 11B-211, CA 11B-602 djust the flow of the water stream to a compliant height. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $2,500 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 843 of 853 Record Number 44327 Drinking Fountain In Maintenance rovide the required clear floor space or reduce the depth of le alcove. $108 $0.00 There is not enough clear floor space for a parallel approach in an alcove. Finding 59.75 inches Code At least 60.00 inches ADA 4.2.4.2, CA 11B-602.2, CA 11B-305.7.2 °riority Not Set .esolution Not Set rogress Not Set Assignment Not Set Emergency Warning Systems Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44329 Visual Alarm There are no visual warning devices at the facility. Finding None Found ADA 4.1.3(14), ADA 4.28, ADA 215.2, CA 11B-215, CA 11B-702 Tnstall visual warning devices integrated with the facility's alarm istem in all common areas. Priority Not Set esolution Not Set rogress Not Set Assignment Not Set $2,200 $0.00 Break/Conference Room Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44365 Employee Break Room Sink counter height does not meet the standards. Finding 35.37 inches Code Up to 34.00 inches CA 11B-606.3 rovide compliant sink. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 844 of 853 Record Number 44366 Employee Break Room Sink knee clearance does not meet the standards. Finding 26.25 inches Code At least 27.00 inches ADA 4.27 rovide compliant sink. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,800 $0.00 Record Number 44367 Employee Break Room The toe kick for the sink in break/conference room is not removed. Finding Not Removed CA 11B-606.2, CA 11B-305, CA 11B-306 emove the toe kick for the sink. riority Not Set esolution Not Set 'rogress Not Set Assignment Not Set $612 $0.00 Record Number 44368 Employee Break Room The pipes are not wrapped for the sink. Finding Not Wrapped CA 11B-606.5 Isulate or otherwise configure the water supply and drain Ipes under the sink to protect against contact. Make certain sere are no sharp or abrasive surfaces under the sink. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $149 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 845 of 853 Record Number 44364 Employee Break Room There is no International Symbol of Accessibility designating this table as accessible Finding None Found ADA 4.27 (stall an International Symbol of Accessibility at the table. riority Not Set .esolution Not Set rogress Not Set _,ssignment Not Set $158 $0.00 Sinks Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44393 Maintenance Bay Sink counter height is not compliant. Finding 35.37 inches Code Up to 34.00 inches ADA 4.27, CA 11B-606.3 provide compliant sink. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $1,800 $0.00 Record Number 44394 Maintenance Bay Soap The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 49.50 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 "elocate the dispenser to the correct height. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $180 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 846 of 853 Record Number 44395 Maintenance Bay Paper Towel The height of the controls and operating mechanisms for the dispenser is not at the correct height. Finding 55.75 inches Code Up to 40.00 inches ADA 4.23.7, ADA 4.22.7, CA 11B-603.5 elocate the dispenser to the correct height. riority Not Set .esolution Not Set rogress Not Set ,ssignment Not Set $180 $0.00 Picnic Areas Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44342 Picnic Tables The required percentage of picnic tables provided are not accessible. Finding None Found Code At least 1.00 tables ADA 5.8, ADA A4.2.5 & A4.2.6, ADA A4.2.6 provide a sufficient number of compliant picnic tables. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $500 $0.00 Lockers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44345 Employee Lockers No accessible lockers were found. Finding Not Available CA 11B-225.2.1, CA 11B-811 rovide a compliant amount of accessible lockers. riority Not Set .esolution Not Set rogress Not Set Assignment Not Set $1,840 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 847 of 853 Accessible Showers Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Record Number 44337 Accessible Shower In The Womens Restroom The grab bars in the accessible shower are not mounted at a compliant height. Finding 38.00 inches Code 33.00 - 36.00 inches ADA 4.21.4, CA 11B-609.4, CA 11B-608.3 Remount the grab bars in the accessible shower to a compliant sight and location. riority Not Set esolution Not Set rogress Not Set .ssignment Not Set $78 $0.00 Record Number 44338 Accessible Shower In The Womens Restroom The grab bar is mounted on walls over the seat. Finding Over Seat ADA 4.21.4, CA 11B-609, CA 11B-608.3 Move the grab bar so that it is mounted on walls opposite and ijacent to the front edge of the seat, but not extended to Iclude that portion of wall over the seat. riority Not Set esolution Not Set rogress Not Set ..ssignment Not Set $1,840 $0.00 Record Number 44339 Accessible Shower In The Womens Restroom Shower seat length is not compliant. Finding Not Accessible ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 "rovide a compliant seat that extends the full length of the lower. Priority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,068 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 848 of 853 Record Number 44340 Accessible Shower In The Womens Restroom The folding seat in the accessible shower is not mounted at a compliant height above the finished floor. Finding 18.75 inches Code 18.00 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 emount the folding seat to a compliant height above the nished floor. °riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 44336 Accessible Shower In The Womens Restroom The center line of the hand-held sprayer unit is not a compliant distance from the rear of the seat edge. Finding 37.50 inches Code Up to 27.00 inches ADA 4.21, ADA 4.21.6, CA 11B-608.5 rovide a compliant hand-held sprayer unit with a hose. riority Not Set .esolution Not Set rogress Not Set ,assignment Not Set $385 $0.00 Record Number 44341 Accessible Shower In The Womens Restroom The water control valve is not mounted at a compliant height. Finding 43.00 inches Code Up to 40.00 inches ADA 4.21.5, CA 11B-608.5 Remount the water control valve. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $554 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 849 of 853 Record Number 44351 Accessible Shower In The Mens Restroom Shower seat length is not compliant. Finding Not Accessible ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 rovide a compliant seat that extends the full length of the lower. riority Not Set .esolution Not Set rogress Not Set .ssignment Not Set $1,068 $0.00 Record Number 44352 Accessible Shower In The Mens Restroom The folding seat in the accessible shower is not mounted at a compliant height above the finished floor. Finding 18.37 inches Code 18.00 inches ADA 4.21.3, CA 11B-608.4, CA 11B-610.3 emount the folding seat to a compliant height above the nished floor. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 44349 Accessible Shower In The Mens Restroom The grab bars in the accessible shower are not mounted at a compliant height. Finding 37.50 inches Code 33.00 - 36.00 inches ADA 4.21.4, CA 11B-609.4, CA 11B-608.3 emount the grab bars in the accessible shower to a compliant eight and location. riority Not Set .esolution Not Set 'rogress Not Set Assignment Not Set $78 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 850 of 853 Record Number 44350 Accessible Shower In The Mens Restroom The grab bar is mounted on walls over the seat. Finding Over Seat ADA 4.21.4, CA 11B-609, CA 11B-608.3 ove the grab bar so that it is mounted on walls opposite and ijacent to the front edge of the seat, but not extended to 'elude that portion of wall over the seat. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,840 $0.00 Record Number 44353 Accessible Shower In The Mens Restroom The water valve distance from seat wall is not compliant. Finding 39.00 inches Code 18.00 - 24.00 inches ADA 4.21.5, CA 11B-608.5 rovide a compliant water valve. riority Not Set esolution Not Set rogress Not Set Assignment Not Set $1,500 $0.00 Record Number 44354 Accessible Shower In The Mens Restroom The water control valve is not mounted at a compliant height. Finding 44.25 inches Code Up to 40.00 inches ADA 4.21.5, CA 11B-608.5 emount the water control valve. °riority Not Set esolution Not Set rogress Not Set Assignment Not Set $554 $0.00 Reach Ranges Finding Recommendation Projected Date Actual Date Est. Cost Act. Cost Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 851 of 853 Record Number 44396 Employee Time Clock In Maintenance Bay Employee Time Clock - Other The highest point of operation for the element is not compliant. Finding 61.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $50 $0.00 Record Number 44397 First Aid Kits In Maintenance Bay First Aid Kits - Other The highest point of operation for the element is not compliant. Finding 65.50 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Not Set .esolution Not Set 'rogress Not Set ,ssignment Not Set $50 $0.00 Record Number 44398 Emergency Eye Wash Station In The Maintenance Bay Emergency Eye Wash Station - Eye Washing Station The highest point of operation for the element is not compliant. Finding 58.00 inches Code 15.00 - 48.00 inches ADA 4.2, CA 11B-308, CA 11B-309 ake sure that the highest point of operation is within the ?commended value. riority Not Set .esolution Not Set 'rogress Not Set .ssignment Not Set $50 $0.00 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 852 of 853 Disability Access Consultants, LLC (DAC) 1-800-743-7067 Page 853 of 853