Loading...
HomeMy WebLinkAboutBSOL2026-0001 Plans Revision 2SHEETINDEX PV-0 COVER PAGE PV-1 SITE PLAN & PLOT PLAN PV-2 ROOF PLAN & MODULES PV-2A ELEVATION VIEW PV-3 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM PV-5 PLACARD & LABELS PV-6 + EQUIPMENT SPECIFICATIONS VICINITY MAP villas�� a Indian Wdls .®, gai Tennis careen\ ells .0 La punt. Cll/fhause ®, Inalan Wells \1 Country Club 10. In Out Burger Costco Wholesale i —a. Rancho La Quin. ®, Country Club t' a Soa Lacuinta 0 - LEGEND PQAWESTPete ❑y,e Mountain Course `u o"o BREAKER UTILITY METER GROUND ELECTRODE d/c SWITCH FUSE D� NEUTRALBAR �L ® GROUND BAR CURRENT CARRYING MICROINVERTER — — CONDUCTORS GROUND CONDUCTOR ® POWER OPTIMIZER NOTES SITE NOTES: -CONSTRUCTION DOCUMENTS ARE BASED ON FIELD INSPECTIONS; ACTUAL CONDITIONS MAY REQUIRE CHANGES. -VERIFY DIMENSIONS AND CONDITIONS; REPORT DISCREPANCIES TO THE ENGINEER. DAMAGE TO STRUCTURES, PIPES, OR ROOFING MUST BE REPAIRED AT NO EXTRA COST. -PROPER ACCESS AND WORKING CLEARANCE AROUND ALL ELECTRICAL EQUIPMENT MUST BE PROVIDED PER CEC 110.26. -A LADDER COMPLIANT WITH CALIFORNIA OSHA REQUIREMENTS SHALL BE IN PLACE FOR INSPECTIONS. -AVOID OBSTRUCTING PLUMBING, MECHANICAL, OR ROOF VENTS WITH PV SYSTEM COMPONENTS. MAINTAIN A MINIMUM OF 6 INCHES OF CLEARANCE FROM VENTS. -INSTALL SMOKE ALARMS AND CARBON MONOXIDE DETECTORS PER CRC R314 AND R315. -MANUFACTURER'S SPECIFICATIONS MUST BE FOLLOWED FOR ALL INSTALLATIONS, ENSURING COMPLIANCE WITH LOCAL JURISDICTION CODES. ELECTRICAL NOTES: -ONLY QUALIFIED PERSONNEL SHALL INSTALL ELECTRICAL EQUIPMENT. NOTIFY UTILITIES BEFORE ACTIVATION AND COORDINATE FOR POWER SHUTDOWNS. -EXTERIOR CONDUITS, FITTINGS, AND BOXES MUST BE WATERTIGHT AND APPROVED FOR WET LOCATIONS. WIRING MUST FOLLOW LABELING AND IDENTIFICATION STANDARDS IN ACCORDANCE WITH CFC 2025. -PV SOURCE, OUTPUT, AND INVERTER CIRCUITS MUST BE IDENTIFIED AT ALL TERMINATION, CONNECTION, AND SPLICE POINTS USING COLOR CODING, MARKING TAPE, OR TAGGING. -MAINTAIN PROPER CLEARANCES AROUND ELECTRICAL INSTALLATIONS. DISCONNECTS MUST BE INSTALLED WITH A MAXIMUM HEIGHT OF 6' 7" AS PER CEC 240.24. Theatrusclub ® „ t PCA WEST 9 CountryClub Le Qumta Museum Q `S ezrdp,e PROJECT SITE silverRocd Resort A Qui th E -MEASURE LINE -TO -LINE AND LINE -TO -NEUTRAL VOLTAGES OF ALL SERVICE ENTRANCE CONDUCTORS BEFORE INSTALLING ANY SOLAR EQUIPMENT. VOLTAGES MUST MEET SYSTEM SPECIFICATIONS (E.G., 240VAC). - VOLTAGE DROP ACROSS THE SYSTEM SHOULD NOT EXCEED 3%. AC CONDUCTORS LARGER THAN 4 AWG MUST BE COLOR -CODED: PHASE A (1-1) - BLACK, PHASE B (1-2) - RED, PHASE C (1-3) - BLUE, NEUTRAL- WHITE/GRAY. -INSTALL PLAQUES AND WARNING LABELS PER NEC AND CEC GUIDELINES, ENSURING ALTERNATE POWER SOURCE PLACARDS ARE UV -RESISTANT AND SECURELY ATTACHED. GROUNDING NOTES: -GROUNDING SYSTEMS MUST COMPLY WITH CEC 690.47 AND 250.50-60. THE EXISTING BUILDING'S GROUNDING SYSTEM MAY BE USED IF ADEQUATE AND ACCESSIBLE; OTHERWISE, A SUPPLEMENTAL ELECTRODE (8-FOOT GROUND ROD WITH ACORN CLAMP) MUST BE INSTALLED. -EXPOSED NON -CURRENT -CARRYING METAL PARTS OF MODULES, FRAMES, AND CONDUCTOR ENCLOSURES MUST BE GROUNDED AS PER CEC 250.134 OR 250.136(A). -GROUNDING ELECTRODE CONDUCTORS MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN #6 AWG AND BONDED TO THE EXISTING GROUNDING SYSTEM TO ENSURE CONTINUITY. -GROUNDING ELECTRODE CONDUCTORS MUST REMAIN CO BUS BARS WITHIN LISTED EQUIPMENT, PER CEC 250.64(C). -FOR DC CIRCUITS, PROVIDE GROUND -FAULT PROTECTION ENSURE DC GROUNDING ELECTRODE CONDUCTORS ARE SIZED BONDED TO AC SYSTEMS AS REQUIRED. -INSTALL ARC -FAULT CIRCUIT PROTECTION FOR DC CIRCU MITIGATE ARCING FAULTS, MEETING CEC 690.11 REQUIREMEN -MAINTAIN WORK SITE SAFETY AND ENSURE ALL GROU INSPECTED AND TESTED FOR PROPER FUNCTIONALITY BEFORE 51 SCOPEOF WORK THE ROOF -MOUNTED PV SYSTEM AT 78490 COYOTE CANYON COURT, LA QUINTA, CA 92253, WILL INTERCONNECT WITH THE UTILITY GRID VIA EXISTING ELECTRICAL SERVICE EQUIPMENT. THE INSTALLATION INCLUDES 41 Q.CELLS Q.TRON BLK M-G2H+430W PV MODULES, AND 2 TESLA PW3 1707000-XX-Y ENERGY STORAGE SYSTEM, AND SAFETY EQUIPMENT. ALL COMPONENTS ARE UL-LISTED, NEC -CERTIFIED, AND INSTALLED PER APPLICABLE CODES AND LOCAL UTILITY REQUIREMENTS. I SYSTEM RATING DC SYSTEM SIZE I 17.630KWDC ACSYSTEMSIZE1 17.101 KWAC EQUIPMENT SUMMARY PV MODULES (41) Q.CELLS Q.TRON BLK M-G2H+ 430W (2) TESLA PW3 1707000-XX-Y BATTERY (2) TESLA PW 3 EXPANSION UNIT MOUNTING SNAPNRACK ULTRA FOOT ANCHOR RAILS SNAPNRACK UR-45 RAIL DESIGN CRITERIA WIND SPEED 97 MPH SNOW LOAD 3 PSF WIND EXPOSURE B GOVERNING CODES 2025 CALIFORNIA ELECTRICAL CODE. 2025 CALIFORNIA RESIDENTIAL CODE. 2025 CALIFORNIA FIRE CODE. 2025 CALIFORNIA BUILDING CODE. 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE. 2025 CALIFORNIA ENERGY CODE. 2025 CALIFORNIA PLUMBING CODE. 2025 CALIFORNIA MECHANICAL CODE. AHJ : LA QUINTA CITY CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 05/15/2026 0 �1� c BSOL2026-0001 - 78490 COYOTE CANYON REVISION 2 - REMOVAL OF ONE MODULE FOR A TOTAL OF 41 MODULES AND NEW SYSTEM SIZE OF 17.63kW. mnnc to.sr srnmennn. rnr. 'ACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-219-6146 LIC. NO.-1074469 CM LID Z N Orn r zz Z U Q LU Z J 0Z) } cy c)Q O ~ v wn n r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 13ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-0: COVER PAGE SITE NOTES • A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. • THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. • THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. • PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED. (N) GATEWAI (E) GARAGE BAC (El (E) MAIN SERVI (N) LOCKABLE AC (N) HEAT DE (N) 2 TESLA PW3 1707000-XX. (N) 2 POWERWALL 3 EXPANSION 1807000-XX-` (N) EMERGENCY DISCONNE BSOL2026-0001 REVISION 2 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 05/15/2026 BY C SCALE: 5/128" = T-0" rxnnr C-7 afim"on. 7nr. PACIFIC COAST GENERATION It 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 ULES ow CM Lo Z CV Orn r ZQ Z U U Q W Z J 0 Z) } Z C1 Q O o _ ~ v 00 n n r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-1: SITE PLAN & PLOT PLAN MOUNTING ROOFS DETAILS ROOF TILT AZIMUTH PANELS COUNT #1 20° 450 12 #2 200 225' 22 #3 200 450 7 ROOF AREA COVERED BY THE ARRAY ARRAY TOTAL ROOF ARRAY AREA AREA COVERAGE (Sq. Ft.) (Sq. Ft.) (%) 860.59 8754 9.83 Q.CELLS Q.TRON BLK M-G2H+430W TOTAL PANELS 41 MODULES PANEL WEIGHT 46.7 LBS PANELDIMENSIONS 67.8x44.6=20.99SF WEIGHT/SF 2.22PSF BUILDING INFORMATIONS AND DESIGN CRITERIA ZONING RESIDENTIAL CONSTRUCTION SFD ROOF TYPE COMP SHINGLE ROOF FRAMING 2"x4" Trusses 24".O.0 RISK CATEGORY II EXPOSURE B CATEGORY SNOW LOAD 3 Ib/SQfT (ASCE 7-22) WIND SPEED (ASCE 7-22) 97 MPH PANEL HEIGHT OFF ROOF 1 4" LEGEND ,s (N) JUNCTION BOX um (E) UTILITY METER -7 (E) MAIN SERVICE PANEL (MSP) nc (N) LOCKABLE AC DISCONNECT ® (N)TESLA POWERWALL3 ® (N) TESLA PW3 EXPANSION UNIT -w (N) TESLA GATEWAY 3 I-- (N) EMERGENCY DISCONNECT I] (E) BACKUP SUB PANEL o❑ -PLUMBING/ATTIC VENTS • -ROOF ATTACHMENT -3/4" EMT CONDUIT 18"SETBACKS 36"SETBACKS STRING 1: (12) Q.CELLS Q.TRON ELK M-G2H+ 430W STRING 2: (12) Q.CELLS Q.TRON BLK M-G2H+ 430W STRING 3: (10) Q.CELLS Q.TRON ELK M-G2H+ 430W STRING 4: (7) Q.CELLS Q.TRON BLK M-G2H+ 430W MODULES MODULES MODULES MODULES W/ (4) MID -CIRCUIT INTERRUPTER 2 HIGH CURRENT W/ (4) MID -CIRCUIT INTERRUPTER 2 HIGH CURRENT W/ (4) MID -CIRCUIT INTERRUPTER 2 HIGH CURRENT W/ (3) MID -CIRCUIT INTERRUPTER 2 HIGH CURRENT ROOF ACCESS POINT JUNCTION BOX 3/4" EMT CONDUIT BSOL2026-0001 REVISION 2 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 05/15/2026 Bv�—D ROOF ACCESS POINT (N) 15 TESLA MID -CIRCUIT INTERRUPTERS MCI-2 HIGH CURRENT SNAPNRACK UR-45 RAIL (84) SNAPNRACK ULTRA FOOT ANCHOR ATTACHMENT C 72" O.C. ROOF #3 (7) Q.CELLS Q.TRON BLK M-G2H+ 430W MODULES ROOF #2 (22) Q.CELLS Q.TRON BLK M-G2H+ 43OW MODULES ROOF #1 (12) Q.CELLS Q.TRON BLK M-G2H+ 43OW MODULES r1r"J//A SCALE: 15/256" = V-0" 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 CM u7 Z N Orn zz Z � U Q LU Z J 0 Z) } Z C1 �Q O O - ~ t 00 n n r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI SENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-2: ROOF PLAN & MODULES INDOOR HEAT DETECTOR O TESLA POWERWALL 3 WITH TESLA POWERWALL 3 WITH 1 EXPANSION UNIT 1 EXPANSION UNIT T�SLa 4S56E3 YNELM TRELTI 0 IMO DISCONNECT INSIDE GARAGE GARAGE TESLA BACKUP TESLA BACKUP SUB PANEL GATEWAY 3 GATEWAY 3 200A Din INSIDE GARAGE GATE AC DISCONNECT MAIN SERVICE PANEL ELEVATION VIEW OUTSIDE 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 CM Lo Z N Orn r ZQ Q U � U Q LU Z J 0 Z) } Z cy O Q z O - ~ t 00 n 1-0 O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-2A: ELEVATION VIEW A PLAN VIEW, FLASHVUE MOUNT, PORTRAIT MODULE Scale: WE SNAPNRACK UNIVERSAL EIVD UR-45 Mill CLAMP PV MODULE SNAPNRACK MIDDLE G E UR-45 Mill CLAMP — — L it FRONT VIEW ATH (COMP), PORTRAIT MODULE Scale: Nis PANEL HEIGHT OFF ROOF I 4" 'NOTE: #14 DIAMETER LAG SCREWS WITH 2.5" EMBEDMENT INTO THE RAFTER ARE USED �DE VIEW, ATH (COMP), PORTRAIT MODULE Scale: Nis PV MODULE FRAME 3 _ MIDDLE CLAMP 8' �\ DETAIL, MID CLAMP PLAN Scale: NTS UR-45 Mill PV MODULE FRAME SNAPNRACK END CLAMP OF DETAIL END CLAMP (UFO) PLAN Scale: NTS SNAPNRACK, ULTRAFOCT BASE, RAFTER, BLACK BOLT, WIDE FLANGE, UR-45 Mill RECESSED, 5-16114-lax\ SNAPNRACK, UR FLIP CLAMP, TAP, BLACK 11N, SS SNAPNRACK UNIVERSAL MID CLAMP UR-45 Mill PV MODULE FRAME #14 LAG SCREWS ROOF PROVIDED BY MANUFACTURER ROOF SHEATHING SNAPNRACK, BUTYL PAD, 2.00IN X 1.441N X.251N /E DETAIL, MID CLAMP FRONT Scale: NTS �1 ATH DETAIL Scale: NTS UR-MANUFACTURER 45 Mill SNAPNRACK END CLAMP PV MODULE FRAME #19 LAG SCREWS UR-45 Mill PROVIDED BY CONNECTED INTO RAFTER DETAIL. END CLAMP (UFO) FRONT �l ATH DETAIL Scale: NTS Scale: NTS 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-219-6146 LIC. NO.-1074469 CM Lo Z N Orn r ZQ Q U � U Q LZ LLJ Z J 0Z) } CY OUQ O O - ~ t 00 n 1-0 O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-3: ATTACHMENT DETAILS CONDUCTOR AND CONDUIT SCHEDULE WITH AMPACITY CALCULATIONS I WIRES ARE 90-C RATED THWN-2 @ 30mC (Cu OR Al) I CONDUIT HEIGHT ABOVE ROOF IS OVER 7/8" IF APPLICABLE TAG E WIRESIZE (AWGORIcc #OF WIRES GROUNDING WIRE SIZE CONDUIT SIZE &TYPE #OFCURRENT CARRYING CONDUCTORS AMBIENT TEMPERATURE ('C) AMPACITYCORRECTION MAX AMPS FOR A75°C RATED USABLE AMPACITY (A) OCPD SIZE (A) CONDUCTOR AMPACITY(A) #CCC FACTOR TEMP FACTOR CORRECTED AMPACITY(A) A #10PVWIRE 2 #6AWGSBC FREEAIR 2 44 N/A N/A N/A N/A N/A N/A N/A B #10AWG(Cu) 6 #8AWG(Cu) 3/4" EMT 6 44 40 0.8 0.87 27.84 35 27.84 N/A B-1 #10AWG(Cu) 4 #8AWG(Cu) 3/4" EMT 4 44 40 0.8 0.87 27.84 35 27.84 N/A C #6AWG(Cu) 3 #8AWG(Cu) 11. EMT 2 44 75 1 0.87 65.25 1 65 65 60 D #3/0AWG(Cu) 3 #6AWG(Cu) 2" EMT 2 44 260 1 1 0.87 1 226.2 1 230 226.2 200 E #2AWG (Cu) 3 #6AWG (Cu) 1" Y. EMT 2 44 145 1 1 0.87 1 126.15 1 130 126.15 125 (N)JUNCTION INVERTER WATTAGE:IISOOW J RRENT BOX 11500W 12—= 4] B2A CONTINWUS LOAD RULE 4]125% 9 .fftA'125=58.9M BSOL2026-0001 BREA 60A 21) q B REVISION 2 c Q CITY OF LA QUINTA - BUILDING DIVISION REVIEWED FOR p)IM°°'-N E°T ID SHUT wN svMTCH TW�LFS TS�Ln CODE — POWERWALL POWERWALL 3 eme Plrvt n� 3 m (Nl tt18 Aw°(cu) COMPLIANCE DATE05/15/2026 Rv��C (N'P wExPANSIDNUMT [(N)TESLA—t]01 ->x (N)JUNCTION BOX AT NEAR MSP BA ERY (N) AC DISCONNECT BOA 4P NON FUSIBLE POWERWALL MTWALM�TaliLiS 3 (N) POWERWTAGI INVERTER F KV = 47. 11500W/OUS= (N)POWE NSIO 1907000.X%-Y E%PaNSION UNIT (N) TESLA PN31707W0.X%-v CONTINUOUS LOAD AD 125% 4] 92A,1 2S= BR. SERVICE INFO. AHJ NAME: LA QUINTA CITY UTILITY PROVIDER: IID MAIN SERVICE VOLTAGE: 240112OV MAIN SERVICE PANEL: 60GA MAIN BREAKER RATING: 600A SERVICE FEED SOURCE: UNDERGROUND THE SUM OF THE AMPERE RATINGS OF ALL OVER -CURRENT DEVICES ON PANEL -BOARDS, BOTH LOAD AND SUPPLY, EXCLUDING THE RATING OF THE OVER -CURRENT DEVICE PROTECTING THE BUS -BAR, SHALL NOT EXCEED THE AMPACITY OF THE BUS -BAR PER NEC 12,13)(3)(3) (E) MN SEWCE PANEL, MAIN E 3R OA (N) TESLA GATEWAY 31841000-XX-Y FROM UTILITY TFR PIHI 3 WE20 rzm9V rvnnc consr crnasnnn. - PACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-219­6146 LIC. NO.-1074469 CM L17 z N Orn i zz av � U Q LZ LLI ~ z J 0Z) } cy �Q O 0 00n n r O U h. 17.630KWDC 17.101 KWAC �END2N AlNG ELE=TR N (E) GARAGE BACKUP Z AHJ : LA QUINTA SUB PANEL RATED 200 A, 240V CITY ft� APN : 770240013 (N) TESLA GATEWAY DESIGNED BY: MEHDIBENSALEM SIGNATURE: M0-11W 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 o�l�� o b ANSI B (E) KITCHEN BACKUP SUB PANEL 11 FF X 17" RATED 125 A, 240V PV-4: ELECTRICAL ti LINE DIAGRAM ❑1 I '' ❑g ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION, (PER CODE: CEC 690.13(B)) 9 ❑ LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), (PER CODE: CEC 690.13) PHOTOVOLTAIC[3] WARNING: POWER SOURCE LABEL LOCATION: CONDUIT, COMBINER BOX 10 (PER CODE: CEC690.31(G)(3)) 11 ❑4 REQ'D BY: CEC 705.12(B)(2)(3)(b) 11 LABEL LOCATION: PV BREAKERS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO 1 SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY AT RAPID SHUTDOWN SYSTEM [CEC 690.56(C)] AWARNING: TRIPLE POWER SOURCE LABEL LOCATION: '' 3 POINT OF INTERCONNECTION (PER CODE: CEC 690.13) 21 REQ'D BY: NEC 705.12(B)(2)(3)(b) LABEL LOCATION: BATTERY BREAKERS WARNING14 CAUTION: SOLAR CIRCUIT R OUTPUT CONNECTION.• No RELOCATEOVERCURRENT DEVICE] LABEL LOCATION: LABEL LOCATION: POINT OF INTERCONNECTION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC (PER CODE: CEC 705.12(2)(b)) CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES [Not required if panelboard is rated not less than sum of ampere AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW ratings of all overcurrent devices supplying it] PENETRATIONS AND ALL COMBINERMUCTION BOXES. (PER CODE: CFC 605.11.1.4) • • - BSOL2026-0001 CONNECTEDI SYSTEM 15 LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3/8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PER CODE: CEC690.15 ,690.13(B)) PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: 47.92A NOMINAL OPERATING AC VOLTAGE: 240V AT EACH AC DISCONNECTING MEANS [CEC 690.13(B) AND 690.541 LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B) LABEL 8 APPLY TO: BACKUP PANEL LABEL LOCATION: APPLY TO: ESS DISCONNECT [NEC 706.7(D)] REVISION 2 THIS • ' • ° - TOTAL• •- CURRENT DEVICES, CITY OF LA QUINTA EXCLUDING MAIN SUPPLYBUILDING DIVISION SHALL •, . REVIEWED FOR CODE REQ'D BY: CEC 705.12(B)(3)(3) COMPLIANCE DATE 05/15/2026 —BY C CAUTION MULTIPLE SOURCES OF POWER POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN BACKUP SUB PANEL 2 TESLA GATEWAY 3 BACKUP SUB PANEL MAIN SERVICE PANEL (YOU ARE HERE) EMERGENCY DISCONNECT (IMO) 2 TESLA PW3 WITH 2 EXPANSION UNIT HEAT DETECTOR LOCKABLE AC DISCONNECT UTILITY METER 78490 COYOTE CANYON COURT, LA QUINTA, CA 92253 V winc r—r crnannnn. rnr. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE- (951)-21 M146 LIC. NO.-1074469 CO U7 Z N Orn zz Z � U Q W Z J 0Z) } Cy OU Q O 0 H 00n n r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-5: PLACARD & LABELS QXRON BLK M-G2+ SERIES 415-440 WID 1108 Cells 22.5% Maximum Module Efficiency ocells L N High performance Ocells N-type N_Q solar cells QANTUM NEO Technology with optimized module layout boosts module efficiency up to 22.5%. 25 A reliable investment ice- Inclusive 25-year product warranty and 25-year linear Waaaaq performance warranty'. 1^�u Enduring high performance Long-term yield secunly with Anti LeTID Technology, Anti PID �. Technologyz, Hot -Spot Protect Extreme weather rating C High-tech aluminium he, frame, called for high snow(810OPa) and wind loads (3600Pa). Innovative all-weather technology Optimal yields, whatever the weather with excellent low -light and temperature behaviour. n The most thorough testing jw( programme in the industry Cools is the first solar module manufacturer to pass the most comprehensive quality programme in the industry: The new "Quality Controlled PV" of the independent certification Institute TIJV Rheinland. ■ Qualifications and Certificates aamralleeP - TDVBheiNane: EdM 61215,2,5:2m5. C E lhRIN�g2m5 ., The ideal solution for: °""' 0 W EN503807 es o N- us Rooftop arrays on ow a ma ner ommiss�on ic8c30snngs aenaina n residential buildings Ocells pursues minimizing paper output in considlrli of the global environment. I. QXRON BLK M-G2+ SERIES ■ Mechanical Specification Format 678In-< 6In- 1.18 In(Ind,ding frame) 0722 TT * t134 TO x 30 mm) We1ght 4671bs(21.2 kg) Front Cover 0131,(3.2 T T) therm, IN prestressed glass with anti -reflection technology Back Cover Composite fllm Frame Black a n,dis,d a1,,Inl,, Ce11 6 x 18 T... trystshine O.ANTUM NEO solar half cells JunEEan box 2.09-3.98in-1.26-236 in•0.59-O.J1 in (534o rt, -E-Ort, -1548mm), Prole- class IP67, wllh hypos diodes Cable 4mm'S,I,rcable;p) k68.91n(17501H x68.91n(1750mm) ConneRor Staubll MC4: IP68 - Electrical Characteristics POWER CLASS 415 420 425 430 435 440 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +S W /-Ow) Power at MPP' Puw Ivy415 420 425 430 435 440 Shon Circus Cur,,, lu [A] 13.49 13.58 13.66 13.74 13.82 13.90 E Open Cireuh Voltage' Va M B-7 3825 39.03 39.32 39.60 39.88 c Current at MIFF law [A] 12.83 12.91 12.98 13.05 13.13 13.20 VOIWgeat MPP Vwp M 32.34 32.54 32.74 32.94 33.14 33.33 Efficiency' r1 1%] x213 x21.5 i218 i22o a22.3 i22Z MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP Pu„ [W] Sol 317.5 321.2 325o 328.8 332.E E ShortCircuit Current lu [A] 10.87 10.94 Too 11.07 11.14 11.20 E Open Circuit Voltage Von M 36.50 361 37.04 37.31 37.58 37.84 2 Cunentat MPP law [A] 10.10 10.15 10.21 10.27 10.33 1038 Witageat MPP V-, m 31.07 31.26 31.46 31.65 31- 32.03 'Measurement tolerances Pup, E3%: Is,: V°c E 59Sat STC: 1000 W/Pr . 2512'C. AM 1.5 according to IEC 609043 •-Boo W/T'. IN MDT, spectrum AM 15 Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ' 'Po iv least Sv5%or nominal power ' "� 4urmgnis1r I.mer.ah.rmax. - p%ae9raaa1.33lo P.rrearAr w 22 all Bala wnhi� m.asuram.m '° vEcas m ry n Y r p ve i0O "' laanpinac[Iwrp,'I ig nr'=°° IIZa in ZOZt ifemwry xolp uhme mmpanunmsrc mnamons Rse.r000wnryem°an°m in TEMPERATURE COEFFICIENTS Temperature Co -butt Pf IK a t%/K] -rat Temperature Coefficient of V°C p [%/Kl -0.24 Temperature Coefficient of PM„ y [%/K] -030 Nominal Module Operating Temperature NMOT TI 1093 A (43i3-q ■ Properties for System Design Maximum System Voltage Vs.s IV] 1000(IEC)/1000(UL) PV hi classincMlon pass ll Maximum Series Fuse Rating [ADC] 25 Fire Rating bit -on ANSI /UL 61730 C/TYPE 2 Max. Design Load, Push /Pu1P [Ibs/fill 1131-Ps)/50(24100 Pa) Permuted Motlule Temperature -40'F up to N85" Max. Test Load, Push /PAR [Ibs/fPI 169(8100 P.R75(3600 Pa) on Contlnu.us Duty -40°C up to -no) 'see Im 011ati" Manual I or o ocells V Mint: toasr assm"on. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951}21 M146 LIC. NO.-1074469 CM LID Z N Orn i zz Z � U Q Lu H Z J 0 Z) } Z C1 �Q p C) ~j V IY 00 ::) r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-6: EQUIPMENT SPECIFICATIONS Powerwall 3 Power Everything Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing up to 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads rated up to 185 LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 Expansions make it easier and more affordable to scale up customers' systems to meet their current or future needs. Powerwall 3 is designed for fast and efficient installations, modular system expansion, and simple connection to any electrical service. 2025 Powerwall 3 Technical Specifications System Technical Model Number 1707000-xx-y Specifications Nominal Grid Voltage (input & Output) 120/240 VAC Grid Type Split phase Frequency 60 Hz Nominal Battery Energy 13.5 kWh AC' Nominal Output Power (AC) 5.8 kW 7.6 kW 10 kW 11.5 kW Maximum Apparent Power 5,800 VA 7,600 VA 10,000 VA 11,500 VA Maximum Continuous Current 24A 31.7A 41.7A 48A Overourrent Protection Device' 30 A 40 A 60 A 60 A Configurable Maximum Continuous Discharge 15.4kWa Power Off -Grid (PV Only, -20°C to 25°C) Maximum Continuous Charge Current / Power 20.8 A AC / 5 kW (Powerwall 3 only) Maximum Continuous Charge Current / Power 33.3 A AC / 8 kW (Powerwall 3 with up to (3) Expansion units) Output Power Factor Rating 0-1(Grid Code configurable) Maximum Output Fault Current (1 s) 160 A Maximum Short-circuit Current Rating 10 kA Load Start Capability 185 LRA Solar to Battery to Home/Grid Efficiency 89%11 Solar to Home/Grid Efficiency 97.5%s Power Scalabilhy Up to 4 Powerwall 3 units supported Energy Scalabilty Up to 3 Expansion units (for a maximum total of 7 units) Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2A and 5 GHz), Ethernet, Cellular (LTE/406) Hardware Interface Dry contact relay, Rapid Shutdown (RSD) certified switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%, ANSI C12.20) Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI), PV Rapid Shutdown (RSD) using Testa Mid -Circuit Interrupters Customer Interface Testa Mobile App Warranty 10 years 'Values provided for 25°C (77°F), at beginning of fife. 3.3 kW charge/discharge power. 'See Powerwall 3 Installation Manual for fuse requirements if using fuse for overcurrent protection. a15.4kW off -grid maximum continuous discharge power is only available if on -grid rating is 11.6 W. If enabled, Powerwall3 moat be installed with an 80 A breaker and appropriately sized conductors. °Typical solar shifting use case. 'Tested using CEC weighted efficiency methodology. aThe customer is expected to provide internet connectivity for Powerwall 3; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. rD�btPRl.'FlIaM7irLi,- 6 manc csasr afimman. rac. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 CM LO Z N Orn Z Z � U Q W Z J 0 Z) } Z C1 � Q Q C) V W 00 ::) r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: M0.11W 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-7: EQUIPMENT SPECIFICATIONS Powerwall 3 Technical Specifications Solar Technical Maximum Solar STC Input 20kW Specifications Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (I.d 15 A76 Maximum Short Circuit Current per MPPT(I) 19A8 ' Only applicable to Powerwall 3 units with 15 A l v on the product label. Otherwise, Powerwall 3 has an I, of 13 A. e When PV strings are combined on the roof and the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs Into a single Input to Intake DC current up to 30 A lap / 38 A Isc (or 26 A I, / 30 A Itt If Powerwall 3Is labeled with 13 A IMp / 15 A J. Environmental Operating Temperature Specifications Operating Humidity (RH) Storage Temperature Maximum Elevation Environment Enclosure Rating Ingress Rating Pollution Rating -200C to 500C (-40F to 1220F) a Up to 100%, condensing -2OoC to 30oC (-4°F to 86°F), up to 95 % RH, non - condensing, State of Energy (SOE): 25% initial 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R IP67 (Battery & Power Electronics) IP55 (Wiring Compartment) PD3 Operating Noise @ 1 m <50 db(A) typical < 62 db(A) maximum a Performance may be de -rated at operating temperatures above 40°C (104°F). Compliance certifications Information Grid Connection Emissions Environmental Seismic 2025 Fire Testing Powerwall3 Datashaet UL 1741, UL 9540, UL 9540A, UL 3741, UL 1741 PCs, UL 1741 SA, UL 1741 SB, UL 1741 Multimode, UL 1973, UL 1699B, UL 1998, GSA C22.2 No. 0.8, CSA C22.2 No. 107.1, CSA C22.2 No. 330, CSA 22.3 No. 9, IEEE 1547, IEEE 1547A, IEEE 1547.1, CA Rule No.21 United States and Canada FCC Part 15 Class B, ICES 003 RoHS Directive 2011/65/EU AC156, IEEE 693-2005 (high) Meets the unit level performance criteria of UL 9540A Powerwall 3 Technical Specifications Mechanical Specifications Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in)'a Total Weight of Installed Unit 132 kg (291.2lb) Weight of Powerwall 3 124 kg (272.5 lb) Weight of Glass Front Cover 6.5 kg (14.5 lb) Weight of Wall Bracket 1.9 kg (4.2 lb) Mounting Options Floor or wall mount 10These dimensions include the glass front cover being installed on Powerwall3. 2025 Powerwa113 Datasheet 1105 mm �609mm� 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 Ml46 LIC. NO.-1074469 CM LO Z N Orn i zz Z U Q LZ LL Z J 0Z) } CY oQ 0 o_ ~ v 00 0 r U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-7A: EQUIPMENT SPECIFICATIONS V rxnnc toesr crnaanan. rnr. Powerwall 3 Expansion Technical Specifications PACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-219-6146 Battery Technical Model Number 1807000-xx-y LIC. NO. -1074469 Specifications Nominal Battery Energy 13.5 kWh Voltage Range 52 - 92 V DCs CM to "Powerwall3 Expansionunitsa. connected in parallel and.. not field serviceable. Z N Orn rQ Z V Environmental Operating Temperature -20°C to 50-C(-4°F to 122°F)a Q U Specifications Operating Humidity(RH) Up to 100%,condensing 2 LL F Storage Temperature -20°C to 30-C (-4°F to 86°F), up to 95% RH, non- = I- - condensing, State of Energy (SOE): 25% initial J Q Z) Maximum Elevation 3000 m (9843 ft) Z O CY Envlronment Indoor and outdoor rated 0 V Q Enclosure Rating NEMA311 ~ CD Ingress Rating IP67 t Pollution Rating PD3 00 "Performance may be de -rated at operating tempera.res above 40-C (104-F). O Compliance certl6cations UL 1973, UL 9540 17.630KWDC Information 17.101 KWAC AHJ : LA QUINTA Mechanical Dimensions 1105 x 609 x 168 mm CITY Specifications (43.5x 24x 6.6 in)- Total Weight of Wall- 118.5 kg (261.21b) APN : 770240013 Mounted Expansion Unit 7 Weight of Expansion Unit 110 kg (242.51b) O Weight of Glass Front 6.5 kg (14.51b) DESIGNED BY: Solar Shutdown Device Technical Specifications The Solar Shutdown Device is a Mid -Circuit Interrupter (MCI) and is integral to the rapid shutdown (RSD) function required for rooftop PV systems in accordance with Article 690 of the NEC. When paired with Powerwall 3, solar array shutdown is initiated by an External System Shutdown Switch or the On/Off Enable switch located on Powerwall 3. Systems not subject to rapid shutdown requirements must still install one or more MCIs for functional purposes; see the Powerwall 3 installation manual for details. Electrical Model MCI-1 MCI-2 MCI-2 Specifications High Current Nominal Input DC Current Rating (I.d 13 A 13 A 15 A Maximum Input Short Circuit Current (l.) 19 A 17 A 19 A Maximum System Voltage 600 V DC 1000 V DC's 1000 V DC15 Maximum Disconnect Voltage's 600 V DC 165 V DC 165 V DC 's Maximum System Voltage is limited by Powerwall to 600 V DC. 'a Maximum Disconnect Voltage is the maximum voltage allowed across each MCI in the open position (Rapid Shutdown Initiated). An individual MCI-2 has a voltage rating of 166V but in combination (connected in the some string) their voltage ratings are additive. RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Operating Temperature -40GCto50oC -45°Cto70°C Specifications (-40oF to 122oF) (-49oF to 158oF) Storage Temperature —3OoC to 7OoC —30oC to 70oC (-22oF to 158oF) (-22oF to 158oF) Enclosure Rating NEMA 4X / IP65 Mechanical Electrical Connections MC4Connector Specifications Housing Plastic Dimensions 125 x 150 x 22 mm 173 x 45 x 22 mm (5x6x1in) (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options Compliance Certifications Information RSD Initiation Method UL 3741 PV Hazard Control (and PVRSA) Compatibility 2025 ZEP Home Run Clip Wire Clip M4 Screw MID) M8 Bolt (5116") Nail / Wood screw UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) External System Shutdown Switch or Powerwall 3 Enable Switch See UL 3741 Application Addendum 6 V WIRC tonsr aam"an. rnr. PACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 CO tt7 Z N Orn ZZ Z U � U Q Lu Z J 0 Z) } Z C1 Q O O - ~ V 00 � r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-8: EQUIPMENT SPECIFICATIONS Gateway 3 Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self -consumption, time -based control, and backup operation. Performance Model Number 1841000-XI-y AC Meter +/- 0.5% Specifications Nominal Grid Voltage 120/240 V AC Communication CAN Grid Configuration Split phase User Interface Teals App Grid Frequency 60 Hz Backup Transition Automatic disconnect for seamless backup Continuous Current 200A Rating Overcurrent 100-200 A Protection Device Service entrance rated Maximum Supply Short 22 kA with Square D or Eaton CSR, BWH, or BW, or Circuit Current Eaton main breaker Square D OOM breakers 25 kA with Eaton main breaker17 Internal Panelboard 200 A IEC Protective Class Class I 8-space/16 circuit breakers Eaton BR, Siemens OP, or Overvoltage Category Category IV Square D HOM breakers rated to 10-125A 17 Only Eaton CSR or BWH main breakers are 25 kA rated. Warranty 10 years Environmental Operating Temperature -20°C to 50°C (-4°F to 122°F) Specifications Operating Humidity (RH) Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Certifications UL 67, UL 869A, UL 916, UL 1741 PCs, Information CSA 222107.1, CSA 22.229 Emissions FCC Part 15, Class B, ICES 003 Mechanical Dimensions 660 x 411 x149 mm Specifications (26 x 16 x 6 in) Weight 16.3 kg (36lb) 4 _ Mounting options Wall mount 660 mm 411 ram �-mm 2025 Powerwall 3 Datashest 7 V WIRC roas7 crnamsnn.7nr. PACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 CO LO Z 04 Orn zz Z U Q W Z J OZ) } Z Q O o _ ~ V 00 � r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-9: EQUIPMENT SPECIFICATIONS SIEMENS Data sheet US2:HNF462J Siemens Low Voltage Circuit Protection Heavy Duty Safety Switches. 60A 4P 600V ®d 4W NON -FUSED HD TYPE 12 mechanical service It (operating cycles) typical 10000 fastening method SURFACE number of poles 4 suitability for operation DISCONNECTING MEAN FOR TWO -SPEED / TWO -WINDING MOTORS ampacity 60 A supply voltage frequency rated value 50/60 Hz Yes product brand name SIEMENS product type designation HEAVY DUTY SWITCH type of electrical connection MECHANICAL LUGS Mechanical Design desian of the housing TYPE 3R/ 3S/ 12113 design of the actuating element SINGLE THROW material STEEL certificate of suitability UL98 last modified: US2:HNF462J Page 1/1 9/16/2021 0 7/10/2023 Subject to change without notice © Copyright Siemens V WIRC toasr crnaannn. rnr. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (919­6146 LIC. NO.-1074469 CO LO Z N Orn i zz Z � U Q LU Z J 0 Z) } Z C1 O Q O O - ~ V 00 n � r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-10: EQUIPMENT SPECIFICATIONS Rotary Actuator Switch - Lockable Off in Plastic Enclosure 1 Rotary Actuator Switch 1 3 position handle (ON - OFF - LOCK -OFF) 1 Plastic Enclosure, IP66 rating 1 NEMA Type 1 1 FIVE YEAR Warranty 1 M12, M16, M20 & M25 entry Maus C E �a IMO Data according to IEC 60947-3, VDE 0660 DC21B Rai ing Poles Number Weight Part Contact 600V 16A 700V 16A 800V 16A 900V 13A 1000V 9A 1200V 6A 15oov 3A in series of Strings 2 1 kg/p Cs. 0.43 Number S116 PEL64R2 Configuration 25A 23A 20A 16A 11A BA 4A 2 1 0.43 S125 PEL64R 2 Y 32A 27A 23A 20A 13A 10A 5A 2 1 0.43 8I32 PEL64R 2 29A 16A 16A 13A 9A 6A 3A 2 1 0.49 S116 PEL64R 2H 45A 23A 20A 16A 11A SA 4A 2 1 0.49 S125 PEL64R 2H -� 50A 27A 23A 20A 13A 10A 5A 2 1 0.49 S13P PEL R 2R 2H rttl 16A 16A MA 16A 16A 16A 16A 4 1 U.47 S116 PEL64R 4S 25A 25A 25A 25A 25A 25A 20A 4 1 0.47 S125 PEL64R 4S 32A 32A 32A 32A 32A 32A 23A 4 1 0.47 SI32 PEL64R 4S ' e 16A 16A 16A 16A 16A 16A 16A 4 1 0.47 S116 PEL64R 4T 25A 25A 25A 25A 25A 25A 20A 4 1 0.47 OF PEL64R 4T 32A 32A 32A 32A 32A 32A 23A 4 1 0.47 SI32 PEL64R 4T 16A 16A 16A 16A 16A 16A 16A 4 1 0.47 S116 PEL64R 4B 25A 25A 25A 25A 25A 25A 20A 4 1 0.47 S125 PEL64R 4B U 32A 32A 32A 32A 32A 32A 23A 4 1 0.47 SI32 PEL64R 4B 16A 16A 16A 13A 9A 6A 3A 2 3 1.57 8116 PEL64R 6 25A 23A 20A 16A 11A BA 4A 2 3 1.57 S125 PEL64R 6 32A 27A 23A 20A 13A 10A 5A 2 3 1.57 S132 PEL64R 6 16A 16A 16A 13A 9A 6A 3A 2 4 1.62 Sit PEL64R 8 25A 23A 20A 16A 11A BA 4A 2 4 1.62 S125 PEL64R 8'� 32A 27A 23A 20A 13A 10A 5A 2 4 1.62 SI32 PEL64R 8 ' • . . . . . . www.imopc.com Rotary Actuator Switch - Lockable Off in Plastic Enclosure Dimensions S116 PEL64R S125 PEL64R SI32 PEL64R ..2, ..2H, .A ..6, ..8, ..3H, . AH 040 5/32 5 e4,2 I i i i i 130 160 IMO 120 www.imopc.com V annc tonsr srna4n4n. rnr. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 co LO z N Orn r zz av � U Q H UJ ~ z J b 5 } z 0 oQ CO � r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-11: EQUIPMENT SPECIFICATIONS H E AT ALARM `AT* HD6135FB 1350 FIXED & RATE OF RISE Microprocessor controlled -Features Fixed Rate and Rate of Rise temperature sensing - allows unit to alarm prior to reaching the fixed temperature setting of 135° F. LATCHING ALARM INDICATOR Remembers which unit initiated an alarm. SILENCE FEATURE Silences nuisance alarms. 17L•X•iCnL[0: FEATURES : kk 0 0'A 1 120V AC, 60Hz Wire -in with 9V Battery Backup Description: The BRK Brands, Inc. Model Number HD6135FB is a wire -in, 120VAC 6011z single and/or multiple station heat alarm designed to supplement smoke alarms in resi- dential and institutional applications including sleeping rooms of hospitals, hotels, motels, dormitories and other multi -family dwellings as defined in standard NFPA 101. Models HD6135FB complies with UL539, CSFM, NFPA 72, HUD, FHA and other agencies that model their codes after the above agencies. They meet build- ing codes where AC and AC/DC with Silence heat alarms are required. The alarms are interconnectable with up to 18 devices, of which 12 can be smoke alarms.This heat alarm is not a smoke alarm nor has it been designated a life safety device. BRK Electronics HD6135FB is designed to give reliable early warning of heat from fire. It is recommended for garages, crawl spaces, bathrooms, kitchens, laundry rooms or other applications not suitable for smoke alarm installations. The unit contains a thermistor that senses heat and will alarm when either the temperature reaches 135°F or when a rate 0f rise of 15°F/minute is sensed by the micropro- cessor. This feature enables a more rapid response to a potential fire. The unit has an 85dB horn, a 9V battery backup power supply, an easy access side -load battery drawer. This alarm features Alarm Latch: Easily identifies initiating alarm even after alarm condition has subsided; Low Battery Silence: Temporarily silence the low battery chirp for up to eight hours; Alarm Silence: Silence alarm for several minutes. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a Quick -Conned wiring harness. Installation is quick, easy and cost effective. Pins are provided to lock battery drawer . • and/or alarm to base. Perfect for 40 apartment, dormitory or hotel applications. Prt �y J First / � tp�pRMx / PPlEPF E 1 ✓ �g MITEO Listed to U® \� RRA� `A"HD6135FB @ (i) U ARCHITECTURAL AND ENGINEERING SPEC The heat alarm shall be a 8RK Model HD6135FB and shall provide at a minimum the following features and functions: 1. Athermistor and microprocessor capable of sensing and alarming at a 135°F fixed temperature level and a 1571min. rate of rise temperature change. 2. The unit shall be capable of self restoring. 3. Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid state piezo horn rated at 85dB at 10 ft. 4. Avisual green LED power -on indicator to confirm unit is receiving power or is in alarm. 5. A full function test button should check all alarm functions by simulating smoke condition, causing the unit to alarm. 6. Silence feature- Temporarily silence unwanted nuisance alarms. 7. Two Locking features- tamper resistant locking pins that lock battery drawer and/or alarm to mounting bracket. 8. The unit shall be capable of operating between -1DoF (-23°C) and 100°F (38°C) and relative humidity between 10%and 90%. 9. The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for two alarm alignment. 10. The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms, 12 of which can be smoke alarms. 11. The unit shall at a minimum meet the requirements of UL539, CSFM, NFPA 72, NFPA 101, ICC. INSTALLATION OF ALARM Installation of this heat alarm mustconformmall localelecMcal codes B and Article 760 of the National Becbical Code (NFPA 70) and NFPA e]s 72. Interconnected unit must meet the following requirements: Total length of win; interconnecting units should be less than 1000 feet, be #18 gauge or larger and be rated at least 30OV. It is recommended that all units be on the same fuse or circuit breaker. If local codes do not permit, be sure the neutral wlro is common to bath phases. THE PARTS OF THIS HEAT ALARM mnai� 543 3. t«k? A�A�wi- ­ ev �nlwlr, � arcerx m,a�e,-ICI A a - onnoa elu„ < s uns•M[cM1N 1i �AMW HzawB A 543 2? aAm�amum tz smol�al_ \' 2. CeP I�Icrgww°Ic 6: aNnrcre�I N! Ite) ctw re(Orarge) car: wca°w TECHNICAL SPECS Alarm Dimensions: 5.6"dia. x 2.0"H Weight: 7.3 oz Operating Voltage: 120VAC 601iz w/ 9V alkaline battery backup Operating Current: 0.05 amps (standby/alarm) Temperature Range: -10°F (-23°C) to 100°F (38°C) Humidity Range: 10% to 95% relative humidity (RH) Audio Alarm. 85dB at 10 feet TestlSilenco: Electronically simulates alarm condition, causing the unit to alarm. Press and hold tesVsilence button. Alarm Reset: Automatic when temperature cools below 130OF Interconnections: Up to 18 units of First Alert or 8RK Smoke, CO and Heat Alarms. Maximum of 12 smoke alarms. See user's manual Heat Sersur: Thermistor Indicator Lights/Sounds: AC Power: Constant Green LED DC Power: Intermittent Green LED Local Ala. Red LED flashes rapidly, audio alarm Remote Alarn: Red LED out. LatchingAlan: Red LED flashes after local alarm Listing: Listed to UL539 Standard SHIPPING SPECS Individual Carton Dimensions Weight Cube UPC 5.50"L x 2.50"W x5.63"H 0.50 lbs. 0.05 ft3 0 29054 50810 2 Master Carton Dimensions 16.81 "L x 10.31 "W x 6.25"H Master Pack 12 Weight 6.3lbs. Cube: 0.63 ft3 12of5: 100 29054 50810 9 Pallet Information Cases per Layer 10 Number of layers: 7 Cases per Pallet: 70 Units per Pallet: 840 Cube: 54.7 ft3 Weight: 5501be. BW®26`6 BIIK Brantls.Inc.asubsitliarYb Newell Brands (NYSE:NWL) 3801 tiberty5-t Poatl Pram a, IL 6050464-8122 AIrightsre ,1 RmtAerl lsa registered tratlsmark °f tM1a FlMAlerl Trust brkelectronics.com BRKi regi erect [mdemarkof BRKBrantl;lnc. CM32]2 V mono toesr crnaenon. rnr. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-219­6146 LIC. NO.-1074469 CM LO Z N 0 W zQ Z � U Q LL1 Z J OZ) } Z C1 OUQ O CD _ ~ V 00 � r O U 17.63OKWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: M0-11W SENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-12: EQUIPMENT SPECIFICATIONS SnapNrack UltraFootTM The Ultimate Attachment for Ultra Rail WIN jw.New Flip Clamp Mount that centers load � over fastener & creates an easier snap -in experience with UR-45 Rail Proprietary fastener reduces the number of screws for deck mounting & increases torque - out strength by 600% compared to #14 wood screws Flexible Rafter & Deck Mounting Options • UltraFoot available in (3) configurations to accomodate rafter & deck mounting based on DeckAnchorT" or wood screw install preferences • The only single lag roof attachment with butyl sealing available • Compatible with pitched roofs and low sloped to flat roofs • Available in domestic content options, refer to "-USA" SKUs Ultra Foot. Rafter 242-10056 & 242-10056-USA • Installs with (1) Sealing Washer Lag, 242-02168 Ultra Foot. Deck 242-10057 & 242-10057-USA • Installs with (2) Sealing Wood Screws, 242-10010, for rafter mounting or (4) Sealing Wood Screws for deck mounting Ultra Foot. Anchor 242-10058 & 242-10058-USA • Installs with (1) Sealing Washer Lag, 242-02168, for rafter mounting or (2) DeckAnchors, 242-10035 - New! Flip Clamp Mount • Ships pre -assembled, eliminating T-Bolts • Allows UR-45 Rail to easily slide & level within the mount. • Positions the load over the fasteners for a stronger roof attachment Features SpeedSeal"+ Technology, a pre -installed butyl pad for easy peel & stick installation Patented SpeedSeal+ Technology • 0.2S" thick industry -leading pre -applied butyl • Innovative bottom design features recessed edges with butyl for firm contact with roof & prevents butyl from squeezing out over time • Creates a watertight seal over all the roof surfaces, including across shingle tabs • TAS 100A Wind Driven Rain Testing Proprietary DeckAnchor Fasteners Wide threads securely grip the wood deck & significantly reduces the potential for over -tightening • Reduces the required screw count in half for deck mounting & increases the torque -out strength by 600% compared to a standard #14 wood screw • ASTM D1761 Screw Capacities • Y�" hex head to maintain the SnapNrack tradition of a single tool Install SnapNrock, 6 WIRC r—r afim"nn. rnr. 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21M146 LIC. NO.-1074469 C0 u7 Z N Orn r ZZ Z U � U Q Lu I— Z J OZ) } Z U �Q O o _ ~ v w � r O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI f3ENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-13: EQUIPMENT SPECIFICATIONS DESCRIPTION: DOC NUMBER: SNAPNRACK, TDS, UR-45 RAIL (USA) SNR-DC-01451 DRAWN BY: PART NUMBER(S): H. WULFEKOETTER 232-10095-USA, 232-10096-USA, 232-10097-USA, SNR SOLAR LLC REV: DATE: ns PlBao uNE. surt6 iBo 232-10130 USA SAN LUIS OBISPO,CCA 93461 USA �r@AP UNITS: IN, LB, DEG [MM, KG, DEG] SHEET: 1:1 C 4/1/2025 SECTION PROPERTIES A 0.319 inz Ixx 0.134 in4 IYy 0.121 in4 Sx (TOP) 0.152 in3 Sx (BOT) 0.156 in3 Sy (LEFT) 0.164 in3 Sy (RIGHT) 0.164 in3 MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): UR-45 RAIL PROPERTIES SKU FINISH RAIL LENGTH (X) WEIGHT (lb) 232-10095-USA MILL 172in 5.55 232-10096-USA BLACK 172in 5.55 232-10097-USA MILL 94 in 3.03 232-10130-USA MILL 186in 6.00 .740 .895 CENTROID .855 6005-T5 ALUMINUM N/A N/A N/A FT-LBS UL 2703, FILE E359313 VARIES, SEE PROPERTIES TABLE V winc consr crnannnn. rnr. PACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 PHONE - (951)-21 M146 LIC. NO.-1074469 CM Lo Z N Orn ZQ Z U U Q LZ LU Z J 0Z) } cy OVQ O O - ~ V 00 n 1-0 O U 17.630KWDC 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHtDI SENSALEM UTC SOLUTIONS DATE: 3/24/2026 ANSI B 11" X 17" PV-14: EQUIPMENT SPECIFICATIONS V winc r—r crnannnn. rnr. PACIFIC COAST GENERATION INC 30135 LITTLE HARBOR DRIVE CANYON LAKE, CA 92587 Bill of Materials PHONE - (95*21 M146 LIC. NO. -1074469 CM u7 Z N Equippements : rn ZQ Q U 2 UQ W Z Z J Cy } >- Z Cy �Q O a0) HCD � r U Name Part Name Qty Breaker Eaton BR260 2 17.630KWDC Others: 17.101 KWAC AHJ : LA QUINTA CITY APN : 770240013 Attachements : SNAPNRACK Composit Shingles ANSI B 11" X 17" PV-15: EQUIPMENT SPECIFICATIONS Name Part Name Qty Solar PV Module Q.CELLS Q.TRON BLK M-G2H+430W 41 BATTERIES PO W E R WALL 3 1707000-XX-Y [240V] 2 BATTERIES POWERWALL 3 EXPANSION 1807000-XX-Y [240V] 2 Gatway TESLA GATEWAY 3 1841000-x1-y 2 Optimizer/MCI TESLA MID -CIRCUIT INTERRUPTERS MCI-2 HIGH CURRENT 15 AC DISCONNECT SQUARED 60A NON FUSIBLE DU222RB 2 EMERGENCY DISCONNECT IMO Disconnect 1 Name Part Name Qty Ground bushing 3/4" 6 Connectors 3/4" 6 Ground bushing 1" 12 Connectors 1" 12 Ground bushing 1"1/4 2 Connectors 1"1/4 2 Ground bushing 2" 2 Connectors 2" 2 Name Part Name Qty Attachments Domestic UltraFoot Anchor 84 RAILS Domestic UR-45 Rail 172" -Mill 30 Bonded Splice Domestic UR-40 & UR-46 Splice - Slv 18 MID CLAMPS Domestic Ultra Rail Mid Clamp - Blk 62 END CLAMS Domestic Ultra Rail End Clamp - Blk 40 GROUNDING LUG OmniLug 10 DESIGNED BY: MEHDIBENSALEM SIGNATURE: MEHt�I 3ENSALEM UTC SOLUTIONS DATE: 3/24/2026