Loading...
HomeMy WebLinkAboutBPOL2025-0138DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool BPOL2025-0138 79070 ASHLEY PL 604374011 Lot 19 MB 263/29 TR 27899 RL, 19 $30,000.00 Declaration / Acknowledgement BUILDING PERMIT athita CALIFORNIA Owner: LUZ CUESTAS PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 07/09/2025 ISSUED DATE: 07/16/2025 Applicant: JUAN C SOTO 81351 AVE 46 SPC #37, INDIO, CA 92201 Contractor: JS INNOVATION POOL AND SPAS INC / 1075986 81351 AVE 46 SPC #37, INDIO, CA 92201 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 7/16/25 8:03 am Page 1 of 3 BUILDING PERMIT Permit Type: Permit Number: Property Address: Pool BPOL2025-0138 79070 ASHLEY PL Use of Permit CUESTAS / NEW POOL & SPA AT REAR YARD [POOL ENGINEERING INC.] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED AS A PART OF. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE -PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Construction Details Engineer of Record MATTHEW THOMPSON Number of Gas Outlet(s) Combination Retaining 0 Wall Linear Footage General Plan Lot Number Legal Description 1 LDR 19 Lot 19 MB 263/29 TR 27899 Quantity of Detached 1 Spa(s)/Water Feature(s) Mechanical Equipment 1 Relocation (QTY) Total Wall Length (Linear Footage) City Limits Lot Size 0 Within La Quinta Limits 961.102 BBQ Electrical (EA) 2 Garden Wall Linear F000tage Zoning 0 RL Subdivision Name TR 27899 Centerlines 88406 Valuation Details Financial Information Invoice No. INV-00016010 Fee Condenser/Compressor PC Building Standards Administration Detached Spa / Water Feature Gas Piping System Outlets PC Receptacle, switch, lighting, or other outlets PC Receptacle, switch, lighting, or other outlets Swimming Pool / Spa PC Swimming Pool / Spa Technology Enhancement Fee Condenser/Compressor Digital Archiving and Records Management Fee - OTC Gas Piping System Outlets Total for Invoice INV-00016010 Fee Amount Amount Paid $31.81 $31.81 $2.00 $2.00 $238.58 $238.58 $31.81 $31.81 $31.81 $31.81 $31.81 $31.81 $129.79 $129.79 $238.58 $238.58 $39.89 $39.89 $47.72 $47.72 $12.00 $12.00 $15.91 $15.91 $851.71 $851.71 Grand Total for Permit $851.71 $851.71 Workflow / Inspections Workflow Step / Action Name Application Completeness Check v.1 Action Type Start Date 07/10/2025 8:07 End Date Submittal Document Verification v.1 Plan Check v.1 Generic Action 07/10/2025 0:00 07/10/2025 8:10 07/10/2025 15:53 Building Review (1 Day) v.1 Permit Issuance v.1 Receive Submittal 07/10/2025 0:00 07/10/2025 15:55 07/10/2025 15:53 07/16/2025 8:03 Printed: 7/16/25 8:03 am Page 2 of 3 BUILDING PERMIT Permit Type: Pool Permit Number: BPOL2025-0138 Property Address: 79070 ASHLEY PL Verify Contractor info & Conditions have been met v.1 Generic Action 07/10/2025 15:55 Verify & Invoice Fees v.1 Generic Action 07/10/2025 15:55 Verify Fee Payment & Issue Permit v.1 Generic Action 07/16/2025 8:03 Print, Attach, and Email Building Permit v.1 Pool Permit Inspection v.1 Create Report 07/16/2025 8:03 07/16/2025 8:03 Pre-Gunite v.1 Inspection Underground Plumbing v.1 Inspection Underground Electrical v.1 Inspection Underground Gas v.1 Inspection Deck Bond v.1 Inspection Pre -Plaster v.1 Inspection Footing v.1 Inspection Bond Beam v.1 Inspections - Final v.1 Inspection Final Pool v.1 Inspection Inspections Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Certificate of Occupancy A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Service Utilities A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 7/16/25 8:03 am Page 3 of 3 5' BLOCK WALL / PL Qvw SPECS AND INFO NAME: Buz CUESTAS NAME: LUZ CUESTAS ADDRESS:79070 ASHLEY PLACE #8 EQUIPOTENTIAL BONDING GRID TO BE INSTALLED AS PER CITY HANDOUT 5' BLOCK WALL / PL 00- 1z" POLY -ETHYLENE GAS PIPE WITH 10 AWG YELLOW TRACER WIRE 1" ELECTRICAL CONDUIT FROM MAIN PANEL TO EQUIPMENT SUB -PANEL GATES SHALL BE SELF CLOSING AND SELF LATCHING AND SHALL SWING OUTWARD AWAY FROM POOL/SPA 35'-6" / \ 20' (V 3'-611 WD \j/ I \ r/ r.` to 5'-01' WD y ilm A \$7 BPOL2025-0138 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COM PUANCE BY: Taylor Tuvell DATE 07//0/2025 CUESTAS / NEW POOL & SPA AT REAR YARD [POOL ENGINEERING INC.] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED AS A PART OF. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE -PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. GAS METER MAIN HOUSE 200 AMP ELECTRICAL PANEL le — SITE PLAN REVIEWED for conformance to tructural details to t hompson Pool Engineering. Inc. Structural details shall take precedence over conflicts with site plan 07/08/2025 Techko-Safety Pool Model S187D Door Alarm (Door Alarm To Be Used In All Doors Going Out To Pool Area) • a 0> IC POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. CITY: LA QUINTA ANTI -COVERS 10" ASME / ANSI APPROVED 7' X 7' @+18" LEVEL SPA W/ TILE SPILLWAYS 6 THERAPY JETS AT RANDOM HEIGHTS 6" TILE WATERLINE 8t-2" POOLGUARD ALARMS 40 AMP POOL SUB -PANEL W/ GFCI BREAKER POOL EQUIPMENT: ST:CA ZIP:92253 POOL SPECS: SIZE: 20' x 12' AREA: 240 SQ FT DEPTH: 3-6" - 5'0" PERIMETER: 64' Gal: 7440 TILE: TBD SKIMMER: 01 RETURNS: 03 SPA SPECS: SIZE: 7'-7' AREA: 49 SQ FT. DEPTH:3-6" PERIMETER: 25 FT. HEIGHT:0" GAL: 545 JETS: 06 TILE: TBD PLUMBING: RETURNS: 03 SKIMMER: 01 POOL MAIN DRAINS: 02 VAC LINE:1 SPA MAIN DRAINS: 02 PVC: 2" SCHEDULE 40 WATER FEATURE: 01 POOL LIGHTS: 03 GAS LINE: POLY PIPE 1.5" SPA LIGHTS: 01 *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED DECK: When the batsmen are loaded, a red LED hem on are from of tse'unit will flash once and a angle bow wall sound This nacelles the urn is set up and reedy to were ENTRY DELAY: Mier the unl is set I.p, there we be an 8-12 a0Gdrtd Neer delay wet the red LED Ilghl flashing Alter this, the alarm a reedy The Sate Pool is designed 10 some aloud alert when chidren abler t rough) a Sate Pod protected door ,• gale. When popery installed. the Safe Poo wit allow adults to pass trough the pi -Mooed door ! gate and Immediately soul all the soundng alarm When powered. the Sale Pod is always in protected mode The alarm will actives the numnl when the dins gale nyK��, by Rine than 1 inch !when the magneltc sensors are apart by mane than 1 inch' Once the alarm a0Ywates a will sound connnlaray until the BYPASS button ix pressed When passing through the docrgale from the opposite ode, whore the additional BYPASS open is included 15189A does not ndude is additional BYPASS button) and mounted, press peat outside mounted BYPASS button 10 temporarily dsanm. Open d0FN. enter and Gb58 tt'e door eeCelY The UM *8 te-srm iHes whin B 12 semnds. When the alarm 004nhe becomes low. or the Ira does not prods. normal alarm sohsd the red light wll Jurrolate Remote reth Ott 5V AAA Daltenes The Safe Poors plastc resists ultraviolet rays evn direct sunlight exposure However. slight discoloration over two es normal. 5' BLOCK WALL / PL Poolguard IMPORTANT OPERATING INSTRUCTIONS MANUAL HELPFUL HINTS &TIPS 'NSF CERTIFIED TO THE ASTAI SAFETY SPECIFICATION F 2208' MODEL PGRM•2 CENSF 85dB Rom at 10 Feet Tot product has been designed to seal i111he detection of unwanted intrusions ra0 InaupeMeed pools. POOLGUARD IS A SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE. -Rae device is not intended 10 replace ary other safety eonaidereton . i.e.. adult s:pernal:A IileglhaM4 fences, gates. pool covers. locks. etc.. and soma devices may not detect gradual entry' WARNING! THE SAFE POOL ALARM 15 EXTREMELY LOUD WHEN ACTIVATED. FOR YOUR SAFETY. NEVER PLACE THE UNIT CLOSE TO YOUR EARS. TO TEST THE ALARM, ALWAYS USE EAR PROTECTION AND DIRECT THE UNIT AWAY BEFORE TESTING r ACTIVATING THE ALARM. IT IS PROHIBITED BY LAW TO REMOVE THE INSTALLED ALARM AFTER IT HAS PASSED INSPECTION I Important Warranty Information: A dated proof of purchase is required for warranty service Customer Service : 1-888-8TECHKO I I-888-883-24 Websne wow tecnKousa.com Mtg By TECHA®' 9767 Research Drive Irvine. CA 92618.4626 MADE IN CHINA USA Patent* No. 5.473,310 No. 8.727.819 No. 7.187,280 NOTICE THIS PRODUCT IS PROTECTED UNDER FEDERAL PATENT TRADEMARK AND COPYRIGHT LAWS AND LAY/5 PREVENTING UNFAM COMPETITION. NO DUPLICATION OR SKADLATIOM OF THIS PRODUCT B PERMITTED EXCEPT BY WRITTEN AUTHORIZATION OF Tr CHKO. INC TECHKO AND 1HE CONFIGURAT4ON OF THIS PRODUCT ARE TRADEMARKS OF TECHKO INC- COPYRIGHT 1994 TECHKO. WC. ALL RIGHTS RESERVED MADE N CHINA Safe pcTM Model S189A / S189D Area Entry Alarm OPERATION MANUAL DECK TYPE: BRUSHED GRAY CONCRETE CONCRETE AREA: TBD TANNING SHELF SIZE: 0' x 0' TANNING SHELF DEPTH: N/A FIRE PIT SIZE: N/A BBQ ISLAND SIZE: N/A POOL EQUIPMENT: CIRCULATION PUMP:PENTAIR INTELLIFLO VSF POOL/SPA HEATER:PENTAIR MASTER TEMP 300,000 BTU POOL/SPA FILTER:PENTAIR CLEAN & CLEAR 320 SQ.FT POOL LIGHTS:PENTAIR GLOBRITE LED SPA LIGHTS:PENTAIR GLOBRITE LED REMOTE CONTROL:PENTAIR EASYTOUCH 4 FUNCTION SALT SYSTEM: PENTAIR I-CHLOR 30 co a_ Q 00 00 z � ♦♦Q CV ti o X �vz aa z00I—ciw o o?z a ar > Q IIIIJ o �Q z v NOTES: 1. ALL EQUIPMENT WILL BE SEISMICALLY ANCHORED 2. ALL GFI OUTLETS WILL BE WEATHER AND TAMPER PROOF 3. ALL OUTLETS SUPPLIED BY SINGLE PHASE. 15A AND 20A . 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP MOTORS ARE REQUIRED TO HAVE GFCI PROTECTION 4. PROVIDE 3611 WORKING CLEARANCE FOR POOL EQUIPMENT MOTORS 5. POOL SAFETY BARRIERS, EXIT DOORS ALARMS, SELF CLOSING SELF LATCHING DOORS 6. POOL AND SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART ANTI -COVERS 10" ASME/ANSI APPROVED SPA TO BE EQUIPPED WITH ANTI -ENTRAPMENT DEVICE (SEC.1404 FEDERAL SWIMMING POOL AND SPA DRAIN COVER STANDARD) PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT STANDARS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS(ASTM) OR THE AMERICAN SOCIETY MECHANICAL ENGINEERS( ASME) IDENTIFY A MINIMUN 3 FEET SEPARATION BETWEEN ALL DRAINS AND NOTE HYDRAULICALLY BALANCED SAFETY FEATURES: ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARD OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGENEERS(ASME) ELECTRICAL : EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELLIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26 BUILDING CODES: 2022 California Residential Based on 2015 International Residential Code (IRC) 2022 California Electrical Code Based on 2014 National Electrical Code (NEC) 2022 California Mechanical Based on 2015 Uniform Mechanical Code (UMC) 2022 California Plumbing Code Based on 2015 Uniform Plumbing Code (UPC) 2022 California Green Code California Building Standard Commission 2022 California Energy Code California Energy Commission INSTALLATION OF THE POOL SYSTEM AND EQUIPMENT WILL COMPLY WITH SECTION 114- MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATER, POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURES RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS Project CUESTAS RESIDENCE Sheet 0 1 Date 7/6/2025 Scale 3/1 6" = 1 '-0" Digitally signed by Matthew Thompson on 07/08/2025 - 1751958000 - 25-06088-dg