Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04-6393 - Title 24
I TITLE 24 REPORT Title 24 Report for: Homewood Suites Hotel La Quinta, CA Project Designer: Knitter and Associates 20151 S.W. Birch, Suite 100 Newport Beach, CA 92660 (949) 752-1177 Report Prepared By: Scott Davenport Linwood Engineering Associates 600 Anton Blvd., 11 th Floor Costa Mesa, CA 92626 (714) 371-4060 Job Number: Date: 2/28/2005 CITY OF AQNIo A BUILDING T. APPROVED FOR CONS T RUC ON DA �600SBY 'L1i The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 04088 UserNumber: 5883 l TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV-MM Envelope Mandatory Measures Form LTG-MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures 1 2 3 123 124 125 EnergyPro 3.1 By EnergySoft Job Number 04088 User Number: 5863 _ 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 PROJECT NAME BATE Homewood Suites Hotel 1. 2/28/2005 PROJECT ADDRESS - La Quinta PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Knitter and Associates 760-360-7886 DOCUMENTATION AUTHOR TELEPHONE --. --ed.t3".. Linwood Engineering Associates (714) 371-4060 Ersipraera'ienf GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 94,848 sq.Ft. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL ® HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION ❑ ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildin si g the performance compliance approach. DOCUMENTATION AUTHOR SIGNATURE I DATE Scott Davenport 212g/0S The Principal Designers hereby certify that the proposed building T!f4Ers"�ighNeffe_sp0edAn the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with thi permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that 1 am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. 3. 1 affirm that 1 am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV71 Required Forms PRINCIPAL ENVELOPE DESIGNER -NAME SIGN LIC. NO. DATE Knitter and Associates G D✓�Z 2 ZS •07 LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures LT -1, LTG-3 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNA LIC. NO. DATE Linwood Enaineering Associates P.A. GI111 2��8�� MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures IMECM, MECH-2 MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME I SIGNAT ILIC. NO. DATE Linwood Engineering Associates P.A. 1AML15 217_gb5- Run Initiation Time: 01/12/05 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By Energy5oft User Number: 5863 Job Number 04088 Page:3 of 126 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-1 DATE Homewood Suites Hotel I 2/28/2005 ANNUAL SOURCE ENERGY USE SUMMARY kBtuls ft- r Standard Proposed Compliance ENERGY COMPONENT DesignDesign 9 Margin 9 ............................................... e Heating Space tin 9 P 1.89 1.89 0. 01 t, Space Cooling 33.92 36-42 -2.50 Indoo F r ans 1.96 4.44 -2.48 Heat Rejection 0.00 0.00 0.00 & " c. Pumps Misc. um 0.00 0.00 0.00 Domestic Hot Water 35.94 31.95 4.00 Lighting 9 9 21.37 20.01 1.36 Receptacle7 14.8 14.87 0.00 Process o.00 0.00 o.00 TOTALS: 109.95 109.56 0.39 Percent better than Standard: 0.4% ( 0.4% excluding process) ( 0.4% excluding process & Building Orientation Norm o deg Conditioned Floor Area 94,848 sqn. Number of Stories 3 Unconditioned Floor Area 0 sgft. Number of Systems 156 Conditioned Footprint Area o SO - Number of Zones 156 Orientation Front Elevation North Left Elevation (East) Rear Elevation south Right Elevation (West) Total Roof Gross Area sgft. sgf1. sqn. sgft. s p. sgft. Glazing Area Glazing sgft. sgft. sgft. sgft. SO. sgft. Ratio 9,690 1,859 19.2% 12,024 1,852 15.4% 10,768 2,181 20.3% 9,757 1,629 16.7% 42,239 7,521 1 25,506 0.0% Standard Proposed Lighting Power Density 1.012 w/sgft. 0,926 w/sgft. Prescriptive Env. Heat Loss 7,545 12,195 Prescriptive Env. Heat Gain 799,317 1,359,526 Remarks: Kun initiation time: uu-iz/u5 u7:39:1tf Kun code: iiu55"35a EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number: 04088 PageA of 126 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME Homewood Suites Hotel DATE 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Port- LPD (W/sf)l CtrL Credits (W/s 2 Tailored Proc, Loads (Wisf) LPf3 (Wfsf) 3 AC-1 Corr. 73/1-lotel Stor. Corridor/Restroom/Support 660 0.583 0.000 0,029 Double Queen 143 LEFT Guestroom HotetfMotel Guest Room 851 0.500 0.000 Double Queen 118 LEFT Guestroom Hotel/Motel Guest Room 320 0.500 0.000 222 2 Bed Double Queen LFT Guestroom Hotel/Motel Guest Room 320 0.500 0.000 247 2 Bed Queen LEFT Guestroom HoteVMotel Guest Room 230 0.500 0.000 249 ACC 2 Bed LEFT Guestroom HoteWotel Guest Room 325 0.500 0.000 326 2 Bed Double Queen RT Guestroom Hotel/Motel Guest Room 570 0.500 0.000 351 2 Bed Queen RIGHT Guestroom Hotel/Motel Guest Room 220 0.500 0.000 353 ACC 2 Bed LEFT Guestroom Hotel/Motel Guest Room 420 0.500 0.000 RTU-12 Corr.1071114 Corridor/Restroom/Su 1,905 0.992 0.000 0,050 RTU-11 Corr. 97/99/93 Right Corridor/Restroom/Su rt 1,5651 1.010 0.000 0.050 RTU-10 Corr. 105/93 Left Corridor/Restroom/Support 1,502 1.095 0.000 0.055 RTU-9 Corr.74/78 Corridor/Restroom/Su port 1,502 1.095 0.000 0.055 RTU-8 Corr.18/49 Corridor/Restroom/Su rt 1,662 0.990 0.000 0.049 RTU-7 Corr. 51/Dome Corr. Corridor/Restroom/Support 1,591 0.871 0.000 0:044 RTU-6 Corr.80/85/87 Corridor/Restroom/Support 1,550 1.099 0.000 0.055 RTU-2 Corr.67171 Corridor/Restroom/Su rt 1,400 1.040 0.000 0.052 AC-8 Pantry/Offices Hotel Function Area 1,665 1.163 0.000 ; ` 0.058 AC-7 Meeting Room 2 Convention/Conference 800 1.085 0.000 0,054 AC-6 MeetingRoom 1 Convention/Conference 1,010 0.982 0.000 :13M Notes, 1. See LTG-1 (hems marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 tterrtsabove cequuespe wl documentafwn EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special Justification and documentation submitted. I Plan I Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp I EnergvPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Paae:5 of 126 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME - - - - - - - DATE - Homewood Suites Hotel 1 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)l Port. LPD (W/sf)1 Ctri. Credits 2 Tailored Prgc. Loads (W/sf) LPt1 (Wtsf) 8 AC-10 Lodge Hotel Function Area 1,700 0.740 0.000 a037' RTU-5 Corr. 55/57/60/Laundry Laundry 1,885 1.011 0.000 0:051 Exercise Room Exercise Room Exercise Center 800 0.620 0.000 0.031 AC-9 Entrance Lobby Lobby (Hotel) 850 0.871 0. z;:>:;;0:044 Employee Break Room Employee Break Room Hotel Function Area 582 0.000 0.000 RTU-1 Corr. 26/41 /Restrooms Corridor/Restroom/Su rt 2,339 1.219 0.000 0`061 Board Room Board Room Hotel Function Area 433 0.859 0.000 '' 0-043 232 Kng Guestroom Hotel/Motel Guest Room 473 0.500 0.000 ; Studio 121 Guestroom HoteVMotel Guest Room 459 0.500 0. 354 ACC Studio Guestroom Hotel/Motel Guest Room 573 0.500 0.000 353 ACC 2 Bed RIGHT Guestroom Hotel/Motel Guest Room 533 0.5001 0.000 351 2 Bed Queen LEFT Guestroom Hotel/Motel Guest Room 591 0.500 0.000 352 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 350 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 348 Double Queen Guestroom Hotel/Motel Guest Room 571 0.5001 0.000 346 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 344 Studio Guestroom Hotel/Motel Guest Room 433 0.500 0.000 343 Studio Guestroom Hotel/Motel Guest Room 433 0.500 0.000 342 Studio I Guestroom Hotel/Motel Guest Room 433 0.500 0.000 341 Studio I Guestroom Hotel/Motel Guest Room 433 0.500 0.000 Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 items above segpire special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST i ne iocai enrorcement agency snouts pay special attention to me items specmea in ints cnectrnst. t nese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted- I pt.. I r:iot.r The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Kun Inniatlon i lme: gin Z/05 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:6 of 126 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME DATE Homewood Suites Hotel -� 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)l Port. LPD (W/sf)l CtrL Credits (Wj 2 Tailored Proc, Loads (W/sf) LPD (Wisf)3 340 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 339 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 338 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 337 Double Queen Guestroom HoteitMotel Guest Room 532 0.500 0,000 336 King Guestroom HoteltMotel Guest Room 473 0.500 0.000 335 King Guestroom Hotel/Motel Guest Room 473 0.500 0.000 334 IQng Guestroom Hotel/Motel Guest Room 473 0.500 0.000 333 lQ Guestroom Hotel/Motel Guest Room 473 0.500 0.000 332 lQng Guestroom Hotel/Motel Guest Room 473 0.500 0.000 331 King Guestroom Hotel/Wel Guest Room 473 0.500 0.000 330 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 329 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 328 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 327 Studio Guestroom HotelfMotel Guest Room 459 0.500 0.000 326 2 Bed Double Queen LFT Guestroom Hotel/Motel Guest Room 405 0.500 0.000 323 King Guestroom HotellMotel Guest Room 486 0.500 0.000 324 King Guestroom Hotel/Motel Guest Room 527 0.500 0.000 321 Kng Guestroom Hotel/Motel Guest Room 554 0.500 0.000 322 King Guestroom Hotel/Motel Guest Room 654 0.500 0.000 300 IGng Guestroom Hotel/Motel Guest Room 1 726 0.500 0.000 Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 Items above require sQecial documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST 1 ne local entorcement agency snouut pay special attention to the items specified in this checklist. These items require special written Justification and documentation, and special verification to be used with the perfomtance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special-uustification and documentation submitted. I Plan F� i The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number. SM Job Number: 04088 Page:7 o1126 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME DATE Homewood Suites Hotel _ 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgR•) Inst. LPD (Wfs►1 Port. LPD Mffsf11 Ctrl, Credits J 2 Tailored p#oc, Loads (w1sQ LPD 1wfSf) 3 RTU-3 Guestroom Hotel/Motel Guest Room 657 0.500 0.000 RTU-4 Guestroom HoteUMotel Guest Room 657 0.500 0.000 303 King Guestroom Hotel/Motel Guest Room 554 0.500 0.000 302 King Guestroom Hotel/Motel Guest Room 654 0.500 0.000 305 King Guestroom HoteUMotel Guest Room 473 0.500 0.000 304 King Guestroom Hotel/Motel Guest Room 5271 0.500 0.000 306 Double Queen Guestroom HoteUMotel Guest Room 622 0.500 0.000 308 Double Queen Guestroom Hotel/Motel Guest Room 622 0.500 0.000 309 Studio Guestroom HoteUMotel Guest Room 475 0.500 0. 310 Studio Guestroom HoteUMotel Guest Room 453 0.500 0.000 311 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 312 Studio Guestroom HoteUMotel Guest Room 453 0.500 0.000 314 King Comer Guestroom Hotel/Motel Guest Room 545 0.500 0.000 315 King Guestroom HoteUMotel Guest Room 473 0.500 0.000 316 King Guestroom HoteUMotel Guest Room 473 0.500 0.000 317 King Guestroom HoteUMotel Guest Room 473 0.500 0.000 318 King Guestroom Hotel/Motel Guest Room 473 0.500 0.000 250 ACC Studio Guestroomn Hotel/Motel Guest Room 573 0.500 0.000 249 ACC 2 Bed RIGHT Guestroom HoteUMotel Guest Room 625 0.500 0.1.4opumergatioin 247 2 Bed Queen RIGHT Guestroom HoteUGuest Room 80Motel 5 0. 0. Notes, 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 tlems above require special EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written Justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. of i.- I The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number.04088 Pane:8 of 126 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME ,DATE Homewood Suites Hotel 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) InsL LPD (W/sf)1 Port. LPD (W/sf)1 GfrL Credits /s 2 Tailored proc, Loads (Wtsf) LPD (Wisf)3 248 Double Queen Guestroom HoteUMotel Guest Room 532 0.500 0.000 246 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 244 Double Queen Guestroom Hotel/Motel Guest Room 571 0.500 0.000 242 Double Queen Guestroom HoteUMotel Guest Room 532 0.5001 0.000 240 Studio Guestroom HoteUMotel Guest Room 433 0.500 0.000 239 Studio Guestroom Hotel/Motel Guest Room 433 0.500 0.000 237 Studio Guestroom Hotel/Motel Guest Room 433 0.500 0.000 238 Studio Guestroom HoteUMotel Guest Room 433 0.500 0.000 236 Double Queen Guestroom HoteUMotel Guest Room 532 0.500 0.000 235 Double Queen Guestroom HoteUMotel Guest Room 532 0.500 0.000 233 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 234 Double Queen Guestroom Hotel/Motel Guest Room 532 0.500 0.000 231 King Guestroom Hotel/Motel Guest Room 473 0.500 0.000 227 Kin Guestroom HoteUMotel Guest Room 473 0.500 0.000 229 King Guestroom HoteVMotel Guest Room 473 0.500 0.000 230 Nng Guestroom Hotel/Motel Guest Room 473 0.500 0.000 :. 228 I -Ong Guestroom Hotel/Motel Guest Room 473 0.500 0.000 > 225 Studio Guestroom HoteUMotel Guest Room 453 0.500 0.000 :...;;: 226 Studio Guestroom HoteUMotel Guest Room 453 0.500 0. 223 Studio Guestroom Hotel/Motel Guest Room 459 0.500 0.000 Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTGA Items above require special Jocwnentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST i ne iocai enforcement agency snouta pay special attention to me items specmea in mis cnecKust. i nese items require special written Justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special Justification_ and documentation submitted. Plan Field The exceptional features fisted in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp 1 EnerpvPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Pape:9 of 126 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME Homewood Suites Hotel DATE ' 2/28/2005j ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area ( n-1 Inst. LPD (WISf), Port. LPD (W/Sf)1 Ctrt. Credits 2 Tailored Pra, Loads (W/sf) LPD QN/sfj 3 224 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 222 2 Bed Double Queen RT Guestroom Hotel/Motel Guest Room 650 0.500 0.000 219 lQng Guestroom Hotel/Motel Guest Room 486 0.500 0.000 220 King Guestroom Hotel/Motel Guest Room 527 0.500 0.000 217 King Guestroom HoteUMotel Guest Room 554 0.500 0.000 218 King Gueshoom Hotel/Motel Guest Room 654 0.500 0.000 203 Kina Guestroom HoteltMotel Guest Room 473 0.500 0.000 201 Irina Guestroom Hotel/Motel Guest Room 554 0.500 0.000 200 King Guestroom Hotel/Motel Guest Room 654 0.500 0.000 202 King Guestroom HoteVMotel Guest Room 527 0.500 0.000 204 Double Queen Guestroom Hotel/Wel Guest Room 622 0.500 0.000 206 ACC-DQ Guestroom Hotel/Motel Guest Room 624 0.500 0.000 207 Studio Guestroom Hotel/Motel Guest Room 475 0.500 0.000 208 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 209 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 210 Studio Guestroom Hotel/Motel Guest Room 453 0.500 0.000 212 King Comer Guestioom Hotel/Motel Guest Room 545 0.500 0.000 213 Kng Guestroom Hotel/Motel Guest Room 473 0.500 0.000 214 King Guestroom Hotel/M atel Guest Room 4731 0.500 0.000 216 King Guestroom Hotel/Motel Guest Room 473 0. 0.000 Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 (tams above require special documerrtation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written Justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special "ustificatior and documentation submitted. Plan I Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Paae:10 of 126 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 :T NAME Homewood Suites Hotel DATE 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgfL) Inst. LPD (W/sfl1 Port. LPD (Wlsf)1 Ctrf. Credfis /s Tailored Proc, Loads (Wl_" (W/sf) 3 215 King Guestroom Hotel/Motel Guest Room 473 0.500 0.000 King 114 Guestroom Hotel/Motel Guest Room 480 0.500 0.000 King 112 Guestroom Hotel/Motel Guest Room 480 0.500 0.000 King 113 Guestroom HoteVMotel Guest Room 480 0.500 0.000 King 111 Guestroom HoteUMatel Guest Room 480 0.500 0.000 King Comer 30 Guestroom Hotel/Motel Guest Room 551 0.500 0.000 Studio 107 Guestroom Hotel/Motel Guest Room 456 0.5001 0.000 Studio 108 Guestroom Hotel/Motel Guest Room 456 0.500 0.000 Studio 106 Guestroom HoteVMotel Guest Room 466 0.500 0. ACC Double 104 Guestroom HoteVMotel Guest Room 600 0.500 0. ACC Double 102 Guestroom Hotel/Motel Guest Roan 600 0.500 0.000 King 100 Gueshoom HoteVMotel Guest Room 528 0.500 0.000 >s`<'s <> < < ` <> ..... King 116 Guestroom Hotel/Motel Guest Room 528 0.500 0.000 Double Queen 118 RIGHT Guestroom HotellMotel Guest Room 760 0.500 0.000 King 115 Guestroom HotellMotel Guest Room 475 0.500 0.000 Studio 123 Guestroom Hotel/Motel Guest Roan 456 0.500 0.000 Studio 120 Guestroom HoteVMotel Guest Room 456 0.500 0.000 Studio 122 Guestroom Hotel/Wel Guest Roan 456 0.500 0.000 Kirm 125 Guestroom HoteVMotel Guest Room 480 0.500 0. Kin 127 Guestroom HoteVMotel Guest Room 4801 0.500 0.000 Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 ttems above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written jusUftcation and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp W A-E 1 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:11 of 126 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME Homewood Suites Hotel DATE 2/28/2005 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Port. LPD (W/sf)l Ctrl, Credits (W/s 2 Tailored proc, Loads (Wlsf) LPD (WJsf)3 King 129 Guestroom Hotel/Motel Guest Room 480 0.500 0.000 Kng 124 Guestroom Hotel/Motel Guest Room 480 0.500 0.000 King 126 Guestroom Hotel/Motel Guest Room 480 0.500 0.000 King 128 Guestroom Hotel/Motel Guest Room 480 0.500 0.000 Double Queen 133 Guestroom Hotel/Motel Guest Room 529 0.500 0.000 Double Queen 131 Guestroom Hotel/Motel Guest Room 529 0.500 0.000 Double Queen 130 Guestroom Hotel/Motel Guest Room 529 0.500 0.000 Double Queen 132 Guestroom Hotel/Motel Guest Roan 529 0.500 0.000 Studio 137 Guestroom Hotel/Motel Guest Roan 432 0.500 0.000 Studio 135 Guestroom Hotel/Motel Guest Roan 4321 0.500 0.000 Studio 134 Guestroom Hotel/Motel Guest Roan 432 0.500 0.000 Studio 136 Guestroom Hotel/Motel Guest Room 432 0.500 0.000 Double Queen 138 Guestroom HoteVMotel Guest Room 529 0.500 0.000 Double Queen 140 Guestroom Hotel/Motel Guest Room 575 0.500 0.000 Double Queen 143 RIGHT Guestroom Hotel/Motel Guest Room 851 0.500 0.000 Double Queen 142 Guestroom Hotel/Motel Guest Room 529 0.500 0.000 Notes: 1. See LTG-1 (items marked with asterisk, see LTG-2 by others) 2. See LTG-3 3. See LTG-4 nems above require special Items d EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special Justification and documentation submitted. Plan Fiotri The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp I EnergvPro 3.1 By EnergVSoft User Number-. 5863 Job Number: 04088 Paae:12 of 126 1 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES F#� Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt y/N Form 3 Reference Location / Comments i Wall Wood 48 0.088 0 90 X11 i R-13 Wall .13.2x4.16 Corr. 731Hotel Stor. 2 Wall Wood 100 0.088 270 90 X11 IR-13Wall .13.2x4.16 Corr. 73/Hotel Stor. all ood 185 0.088 0 90 X R-13Wall .13.2x4.16 Corr. 73/Hotel Stor. all ood 20 0.088 270 R-13 Wall .13.2x4.16 Guestroom all ood 38 0.088 0 90 R-13 Wall .13.2x4.16 Guestroom r all ood 68 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom Wall ood 69 0.088 315 90 R-13 Walt .132x4.16 Guestroom all Wood 69 0.088 315 90 X R-13 Wall .13.2x4.16 Guestroom 9 all Wood 68 0.088 225 90 R-13 Wall .13.2x4.16 Guestroom 10 all Wood 38 0.088 0 90 X R-13 Wall .132x4.16 Guestroom 11 Wall Wood 20 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom 12 all Wood 249 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom 13 all Wood 78 0.088 180 90 R-13 Wall .13.2x4.16 Guestroom 14 Roof ood 570 0.051 0 0 X R-19 Roof R.19.2x8.16 Guestroom 15 all Wood 69 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 16 Wall ood 160 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom 17 Roof Wood 220 0.051 0 0 X R-19 Roof R.19.2x8.16 Guestroom 18 all Wood 64 0.088 270 90 R-13 WaU .13.2x4.16 Guestroom 19 Roof ood 420 0.051 0 0 R-19 Roof R.192x8.16 Guestroom 20 WallLWood 249 0.088 270 90 X R-13 Wall .132x4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing Check box if Building is - 100,000 sgft of CFA and - 10,000 sgft vertical glazing then NFRC Certification is required. Follow NFRC 100-SB Procedures and submit NFRC Label Certificate Form_ # Type Area -Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 20 1.040 270 0.63 Single NonMtl Tinted Default Suestroom 2 Window 28 1.040 225 0.63 Single NonMtl Tinted Default Guestroom 3 Window 7 1.040 315 0.63 Single NonMtl Tinted Default Suestroom 4 Window 7 1.040 315 0.63 Sin le NonMtl Tinted Default 3uestroom 5 Window 28 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 6 Window 20 1.040 270 0.63 Single NonMU Tinted Default 3uestroom 7 Window 46 1.040 270 1 0.63 Single NonMtl Tinted Default 3uestroom 8 Window 18 1.040 180 0.63 Si le NonMtl Tinted Default uestroom 9 Window 7 1.040 135 0.63 Sin le NonMtl Tinted Default uestroom 10 Window 28 1.040 225 0.63 Single NonWl Tinted Default 3uestroom 11 Wiindow 26 1.040 270 0.63 Single NonMtl Tinted Default uestroom 12 Window 46 1.040 270 0.63 Single NonMtl Tinted Default 3uestroom 13 Window 26 1 1.040 1 180 0.63 Single NonMtl Tinted Default uestroom 14 Window 40 1.040 45 0.63 Single NonMtl Tinted Default Dorr. 51 /Dome Corr. 15 indow 64 1.040 0 0.63 Single NonWl Tinted Default orr. 51/Dome Corr. EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 5 None 0.76 6 None 0.76 7 None 0.76 8 None 0.76 9 None 0.76 10 None 0.76 11 1 None 0.76 12 None 0.76 13 None 0.76 14 None 0.76 15 None 0.76 Run Initiation Time: 0 1 05 07 9:18 Run Code: 11 055U358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page: 13 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-] PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location / Comments 21 Wall Wood 70 0.088 180 90 R-13 Wall .13.2x4.16 Guestroom 22 Wall Wood 51 0.088 90 90 X R-13 Wall .13.2x4.16 Corr. 107/114 23 Wall Wood 57 0.088 180 90 XII I R-13 Wall .13.2x4.16 Corr. 107/114 24 Wall Wood 51 0.088 90 90 x1l I R-13 Wall .13.2x4.16 Corr. 107/114 25 Wall Wood 51 0.088 135 90 x1l IR-13WaH .13.2x4.16 Corr. 97/99/93 Right 26 Wall Wood 51 0.088 315 90 X11 I R-13 Wall .13.2x4.16 Corr. 105/93 Left 27 Wall Wood 57 0,088 180 90 x1l I R-13 Wall .13.2x4.16 Corr. 105/93 Left 28 all ood 51 0.088 315 90 x1l I R-13 Wall .13.2x4.16 Corr. 7478 29 all ood 57 0.088 180 90 R-13 Wall .13.2x4.16 Corr. 74178 30 all ood 51 0.088 315 90 R-13 Wall .13.2x4.16 Corr.18149 31 Wall ood 57 0.088 180 90 R-13 Wall .13.2x4.16 Corr. 18/49 32 all ood 57 0.088 180 90 R-13 WaN .13.2x4.16 Corr. 51/Dome Corr. all ood 55 0.088 45 90 R-13 Wall .13.2x4.16 Corr. 51/Dome Corr. 34 all J33 ood 145 0.088 0 90 R-13 Wall .13.2x4.16 Corr. 51/Dome Corr. 35 all ood 114 0.088 180 90 XII I R-13 Wall .13.2x4.16 Car. 51/Dome Corr. 36 IIVVali ood 16 0.088 135 1 90 R-13 Wall .13.2x4.i6 Car. 51/Dome Corr. 37jail ll ood 51 0.088 90 90ER-L13Walll 13 Wall .13.2x4.18 Corr. 51 /Dome Corr. 38ll ood 51 0.088 90 90 MI- Corr. Corr. 80/85/87 39ll ood 51 0.088 90 90RAl 13.2x4.16 Car. 80/85/87 40 ood 51 0.088 135 90 fW 13 2x41 61 orr. 67f71 FENESTRATION SURFACES Site Assembled Glazing Check box if Building is - 100,000 sqft of CFA and - 10,000 sqft vertical glazing then NFRC Certification is required. Fnllnw NFRr: 1r1n_SR Prnrprbirac and suhmit NFRC: I ahel i:Prtifirate Form_ # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 16 Window 57 1.040 180 0.63 Sin le NonMtl Tinted Default 7.orr. 51/Dome Corr. 17 Window 32 1.040 135 0.63 Si le NonMtl Tinted Default orr. 51 /Dome Corr. 18 Window 15 1.040 225 0.63 Single NonMtl Tinted Default -:)ant/Offices 19 Window 22 1.040 225 0.63 Sin le NonMtl Tinted Default )art/Offices 20 Window 46 1.040 45 0.63 Single NonNI Tinted Default Aeetinq Room 2 21 Window 59 1.040 45 0.63 Sin le NonMU Tinted Default Aeetinq Room 1 22 Window 254 1.040 45 0.63 Single NonMtl Tinted Default od e 23 Window 42 1.040 180 0.63 Sin le NonMtl Tinted Default ixercise Room 24 Window 70 1.040 270 0.63 Single NonMti Tinted Default xercise Room 25 Window 61 1.040 225 0.63 Single NonMtl Tinted Default VEntrance Lobby 26 Window 50 1.040 90 0.63 Single Non Tinted Default mployee Break Room 27 Window 35 1.040 225 0.63 Sin le NonMt1 Tinted Default 13oard Room 28 Window 46 1.040 315 0.63 Single NonWI Tinted Default uestroom 29 indow 21 1.040 135 0.63 Single NonMtl Tinted Default uestroom 30 Window 46 1.040 180 1 0.63 Single NonMtl Tinted Default Puestroom EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H . LExt.RExt. Dist. Len. H Dist. Len. Hat. 16 None 0.76 17 None 0.76 18 None 0.76 19 None 0.76 20 None 0.76 21 None 0.76 22 None 0.76 23 None 0.76 24 None 0.76 25 None 0.76 26 None 0.76 27 None 0.76 28 None 0.76 29 None 0.76 30 None 0.76 Run Initiation i • 0111 105 07: 9'18 Run Code: 11055"3 8 EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number: 04088 Page:14 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 (PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location / Comments 41 Wall Wood 19 0.088 315 90 X R-13 Wall .13.2x4.16 Pantry/Offices 42 Wall Wood 54 0.088 225 90 XII JR-13Wall .13.2x4.16 Pantry/Offices 43 all Wood 78 0.088 1 225 90 XII JRA3Wall .13.2x4.16 Pantry/Offices 44 Wall Wood 129 0.088 1 45 90 x1l I R-13 Wall .13.2x4.16 Pant/Offices 45 Wall Wood 133 0.088 45 90 x1l I R-13 Wall .13.2x4.16 Pantry/Offices 46 Wall Wood 162 0.088 315 90 XII I R-13 Wall .13.2x4.16 Pantry/Offices 47 Wall ood 83 0.088 225 90 x1l JR-13Wall .13.2x4.16 Pantry/Offices 48 Wall Wood 173 0.088 45 90 x1l I R-13 Wall .13.2x4.16 Meeting Room 2 49 Wall Wood 207 0.088 45 90 XII I R-13 Wall .13.2x4.16 Meetinq Room 1 50 Wall Wood 248 0.088 315 90 XII I R-13 Wall .13.2x4.16 Lodge 51 Wall Wood 248 0.088 135 90 XII I R-13 Wall .13.2x4.16 Lodge 52 all ood 336 0.088 45 90 x1l JR-13Wall .13.2x4.16 L 53 all ood 31 0.088 90 90 XII I R-13 Wall AIN4.16 Corr. 55/57/60/Laundry 54 all ood 100 0.088 180 90 XII I R-13 Wall .13.2x4.16 Corr. 55157160/Laundry 55 Wall Wood 113 0.088 90 90 XII I R-13 Wall .1320.16 Corr. 55157/60/Laundry 56 Wall 'Wood 64 0.088 90 90 R-13 Wall .13.2x4.16 Corr. 55/57160]Laundry 57 all Wood 51 0.088 90 90 R-13 Wall .13.2x4.16 Corr. 55/57/60/Laundry 58 Wall Wood 51 0.088 270 90 R-13 Wall .13.2x4.16 Corr. 55/57/60/Laundry 59 Wall Wood 220 0.088 180 90 R-13 Wall .13.2x4.16 Corr. 55/57160/Laundry 60 all Wood 168 0.088 180 90 X R-13 Wall .13.2x4.16 Exercise Room FENESTRATION SURFACES Site Assembled Glazing Check box if Building is - 100,000 sgft of CFA and - 10,000 sqft vertical glazing then NFRC Certification is required. 11 Follow NFRC 1 nO-SB Procedures and submit NFRC Label Certificate Form_ # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 31 Window 26 1.040 180 0.63 Si le NonMti Tinted Default Guestroom 32 Window 34 1.040 270 0.63 Si le NonMtl Tinted Default 3uestroorn 33 Window 46 1.040 90 0.63 Single NonMtl Tinted Default 3uestroom 34 Window 46 1.040 90 0.63 Sin le NonMtl Tinted Default 3uestroom 35 Window 46 1.040 0 0.63 Sin le NonMtl Tinted Default 3uestroorn 36 jWindow 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroorn 37 Window 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroorn 38 Window 46 1.040 180 0.63 Single NonMt! Tinted Default 3uestroom 39 Window 46 1.040 0 0.63 Si le NonMtI Tinted Default 3uestroorn 40 Window 46 1.040 180 0.63 Sin le NonMtl Tinted Default 3uestroorn 41 Window 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroom 42 Window 46 1.040 180 0.63 Si le NonMO Tinted Default 3uestroorn 43 IWindow 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroom 44 indow 46 1.040 180 0.63 Sin le NonMtl Tinted Default uestroom 45 Window 46 1.040 315 0.63 Single NonMtl Tinted Default 3uestroom EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. H t. Dist. Len. Hat. 31 None 0.76 32 None 0.76 33 None 0.76 34 None 0.76 35 None 0.76 38 None 0.76 37 None 0.76 38 None 0.76 39 None 0.76 40 None 0.76 41 None 0.76 42 None 0.76 _431 None 0.76 44 None 0.76 45 None 0.76 Run Initiation Time: 0 11210 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number. 04088 Page:15 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt y/N Form 3 Reference Location / Comments 61 Wall Wood 235 0.088 270 90 X R-13 Wall .13.2x4.16 Exercise Room 62 all Wood 24 0.088 315 90 X I IR-13Wall .13.2x4.16 Entrance Lobby 63 Wall Wood 120 0.088 225 90 X I I R-13 Wall .13.2x4.16 Entrance Lobby 64 Wall Wood 24 0.088 135 90 x I I R-13 Wail .13.2x4.16 Entrance Lobb 65 Wall Wood 178 0.0B8 90 90 x I I R-13 Wall .13.2x4.16 Break Employee ee Room 66 Wall Wood 38 0.088 180 90 X I JR-13Wall .13.2x4.16 Employee Break Room 67 Wall Wood 51 0.088 135 90 x1l JR-13Walf .13.2x4.16 Corr. 26141/Restrooms 68 Wall Wood 22 0.088 45 90 XII I R-13 Wall .13.2x4.16 Corr. 26/41/Restrooms 69 all Wood57 0.088 180 90 R-13 Wall .13.2x4.16 Corr. 26/41/Restrooms 70 Wall 51 0.088 135 90 X R-13 Wall .13.2x4.16 Corr. 26/41/Restrooms 71 Wall 148 0.088 225 90 R-13 Wall 13.2x4.16 Board Room 72 all 19 0.088 225 90 R-13 Wall .13.2x4.16 Guestroom 73 Wall 182 0.088 315 90 R-13 Wall .13.2x4.16 Guestroom74 Wall 109 0.088 135 90 X R-13WaH .13.2x4.16 Guestroom 75 Roof573 0051 0 0 R-19 Roof R.19.2x8.16 Guestroom76 Wall238 0.088 90 90 X11 JR-13Wall .13.2x4.16 Guestroom 77 Wall ood 184 1 0.088 180 90 X R-13 Wall .13.2x4.16 Guestroom 78 Roof Wood 533 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 79 Wall Wood 158 1 0.088 180 90 1 JR-13Wall .13.2x4.16 Guestroom 80 Roof lWood 591 1 0.051 1 0 0 X R-19 Roof R.19.2x8.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing n Check box if Building is- 100,000 sgft of CFA and- 10,000 sgft vertical glazing then NFRC Certification is required. Fnllnw NFRC IM-RR PrnnPA trP-, aril cuhmil NFRC I ahPI r:PAfirntP_ Fnrm # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location I Comments 46 Window 46 1.040 135 0.63 Single NonMItI Tinted Default uestroom 47 Window 46 1.040 315 0.63 Single NonMtl Tinted Default uestroom 48 Window 46 1.040 135 0.63 Single NonMtl Tinted Default 3uestroorn 49 Window 46 1.040 315 0.63 Single NonMItl Tinted Default 3uestroorn 50 Window 46 1.040 135 1 0.63 Single NonMtl Tinted Default 3uestroorn 51 Window 46 1.040 315 0.63 Single NonMtl Tinted Default uestroom 52 Window 46 1.040 135 0.63 Single NonMtl Tinted Default 3uestroom 53 Window 46 1.040 315 0.63 Single NonMtl Tinted Default 3uestroorn 54 Window 18 1.040 135 0.63 Sin le NonMtl Tinted Default 3uestroom 55 Window 7 1.040 315 0.63 Single NonMtl Tinted Default 3uestroom 56 Window 28 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 57 Window 46 1.040 45 0.63 Single NonMtl Tinted Default 3uestroom 58 Window 46 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 59 indow 46 1.040 45 0.63 Single NonMtl Tinted Default uestroom 60 Window 46 1.040 225 0.63 Single NonMtI Tinted Default uestroom EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 46 None 0.76 47 None 0.76 48 None 0.76 49 None 0.76 0.76 0.76 rNone 0.76 0.76 0.76 55 1 None 0.76 None 0.76 None 0.76 None 0.76 E None 0.76 None 0.76 Run Initiation Time: 111 105 0 :39: 8 Run ode: 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:16 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location / Comments 81 wall ood 38 0.088 0 90 R-13 Walf .13.2x4.16 Guestroom 82 Wall ood 38 0.088 180 90 X11 IR-13'Wall .13.2x4.16 Guestroom 83 Wall 102 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom 84 Roof 532 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 85 all 38 0.088 180 90 R-13 Wall .13.2x4.16 Guestroom 86 all rood 184 0.088 90 90 R-13 Wall .13.2x4.16 Guestroom 87 Roof 532 0.051 0 0 R-19 Roof .19.2x8.16 Guestroom 88 all 38 0.088 0 90 R-13Wall .13.2x4.16 Guestroorn89 all 184 0.088 90 90 X I JR-13Wall .13.2x4.16 Guestroom 90 Roof Wood 571 1 0.051 0 1 0 xj I R-19 Roof R.19.2xB.16 Guestroom 91 wall Wood 38 0.088 90 90 X I IR-13Wall .13.2x4.16 Guestroom 92 Wall Wood 204 0.088 0 90 X I JR-13Wall .13.2x4.16 Guestroom 93 Roof Wood 532 0.051 0 0 X I I R-19 Roof R.19.2x8.16 Guestroom 94 Wall Wood 38 0.088 270 90 x I JR-13WaN .13.2x4.16 Guestroom 95 Wall Wood 182 0.088 0 90 X I IR-13Wal .13.2x4.16 Guestroom 96 Roof ood 433 0.051 0 0 xjj I R49 Roof R.19.2x8.1 Guestroom 97 Wall ood 182 0.088 0 90 x1l JR-13Wall .13.2x4.16 Guestroom 98 Roof ood 433 0.051 0 0 X11 I R-19 Roof R.19.2x8.16 Guestroom 99 Wall ood 182 0.088 180 90 R-13 Wall .13.2x4.16 Guestroom 100 Roof ood 433 0.051 0 0 X11 I R-19 Root R.19.Z0.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing Check box if Building is - 100,000 sqft of CFA and - 10,000 sgft vertical glazing then NFRG Certification is required. Fnllnw NFRC 1nr>-SR Prrr_edurec and submit NFRC Label Certificate Form_ # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 61 Window 57 1.040 225 0.63 Single NonMtl Tinted Default Guestroom 62 Window 28 1.040 45 0.63 Single NonMtl Tinted Default 3uestroom 63 Window 28 1.040 45 0.63 Single NonMtl Tinted Default uestroom 64 Window 46 1.040 45 0.63 Single NonMtl Tinted Default Ouestroom 65 Window 46 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 66 Window 46 1.040 45 0.63 Single NonMtl Tinted Default 3uestroom 67 Window 46 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 68 Window 7 1.040 315 0.63 Single NonMtl Tinted Default 3uestroom 69 Window 42 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 70 Window 7 1.040 135 0.63 Single NonMtl Tinted Default 3uestroom 71 Window 42 1.040 225 0.63 Single NonMtl Tinted Default uestroom 72 Window 1 18 1.040 315 0.63 Single NonMtl Tinted Default 3uestroom 73 Window 46 1.040 1 135 0.63 Single NonMtl Tinted Default 3uestroom 74 indow 46 1.040 1 315 0.63 1 Single NonMtl Tinted Default uestroom 75 Window 46 1 1.040 135 0.63 1 Single NonMtl Tinted Default uestroom EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 61 None 0.76 62 None 0.76 63 None 0.76 64 None 0.76 65 None 0.76 66 None 0.76 67 None 0.76 68 None 0.76 69 None 0.76 70 None 0.76 71 None 0.76 72 1 None 0.76 73 None 0.76 74 None 0.76 75 None 0.76 Run Initiation Time: 011 05 0 :39:18 Run Code: '1105544358 EnergyPro 3.1 By EnergySoft User Number. 58W Job Number. 04088 Page:17 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-, PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac- Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location ! Comments 101 Wall Wood 1 182 0.088 0 90 X R-13 Wa11 .13.2x4.16 Guestroom 102 Roof Wood 433 0.051 0 0 XI I R-19 Roof R.19.2x8.16 Guestroom 103 Wall Wood 182 0.088 180 90 X R-13 Wall .13.2x4.16 Guestroom 104 Roof Wood 532 0.051 0 0 x I R-19 Roof R.19.2x8.16 Guestroom 105 Wall Wood 38 0.088 90 90 x III R-13 Wall .13.2x4.16 Guestroom 106 Wall Wood 182 0.088 0 90 x 11 R-13 Wall .13.2x4.16 Guestroom 107 Roof Wood 532 0.051 0 0 x 111 R-19 Roof R.19.2x8.16 Guestroom 108 Wall Wood 38 0.088 90 90 X III R-13 Wall .13.2x4.16 Guestroom 109 all Wood 182 0.088 180 90 R-13 Wall .13.2x4.16 Guestroom 110 Roof Wood 532 0.051 0 0 X R-19 Roof R.19.ZO.16 Guestroom 111 all Wood 38 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom 112 all Wood 184 0.088 0 90 X R-13 Wall .13.2x4.16 Guestroom 113 Roof Wood 532 0.051 0 0 R-19 Roof R.192x8.16 Guestroom 114 Wall Wood 38 0.088 270 90 R-13 WaN .13.2x4.16 Guestroom 115 Wall Wood 184 0.088 180 1 90 XI IR-13Wall .13.2x4.16 Guestroom 116 Roof Wood 473 0.051 0 1 0 X R-19 Roof R.192x8.16 Guestroom 117 all Wood 19 0.088 225 90 X R-13 Wall .132x4.16 Guestroom 118 all Wood 182 0.088 315 90 R-13 Wall .132x4.16 Guestroom 119 Roof Wood 473 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 120 Wall Wood 19 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing n Check box if Building is- 100,000 sgft of CFA and- 10,000 sgft vertical glazing then NFRC Certification is required. Fnllnw NFRr IMAR PrnradllrPc and cuhmit NFRC I ahel Certificate Form_ # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 76 Window 46 1.040 135 0.63 Single NonMtl Tinted Default uestroom 77 Window 18 1.040 90 0.63 Si le NonMtl Tinted Default 3uestroom 78 Window 46 1.040 270 0.63 Single NonMtl Tinted Default 3uestroorn 79 Window 46 1.040 90 0.63 Sin le NonMH Tinted Default uestroom 80 Window 46 1.040 1 270 0.63 Single NonMtl Tinted Default 3uestroorn 81 Window 46 1.040 1 90 0.63 Single NonMtl Tinted Default 3uestroom 82 Window 46 1.040 180 0.63 Sin le NonMtl Tinted Default 3uestroorn 83 Window 34 1.040 180 0.63 Sin le NonMtl Tinted Default 3uestroorn 84 Window 40 1.040 270 0.63 Single NonMtl Tinted Default 3uestroorn 85 Window 46 1.040 90 0.63 Single NonMtl Tinted Default 3uestroom 86 Window 46 1.040 90 0.63 Sin le NonMtl Tinted Default Questroorn 87 Window 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroorn 88 Window 46 1.040 0 0.63 Sin le NonMtl Tinted Default 3uestroorn 89 indow 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroorn 90 Window 46 1.040 180 0.63 Single NonMtl Tinted Default 3uestroorn 1 EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. Hat. 76 None 0.76 77 None 0.76 78 None 0.76 79 None 0.76 80 None 0.76 81 None 0.76 82 None 0.76 83 None 0.76 84 None 0.76 85 None 0.76 86 None 0.76 87 1 None 0.76 88 None 0.76 89 None 0.76 90 None 0.76 Run InitiationTime: 0111210 7:39:18 Run C • 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:18 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments Wall Wood 182 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom [122 Roof Wood 473 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom all ood 19 0.088 45 90 X R-13Wall .13.2x4.16 Guestroom Wall Wood 182 0.088 315 90 R-13Wall .13.2x4.16 Guestroom Roof Wood 473 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom Wall Wood 19 0.088 45 90 R-13Wall .13.2x4.16 Guestroom Wall Wood 182 0.088 135 90 X JR-13Wall .13.2x4.16 Guestroom 128 Roof lWood 473 0.051 0 0 X I R-19 Roof R.19.2x8.16 Guestroom 129 Wall Wood 19 0.088 225 90 X JR-13Wall .13.20.16 Guestroom 130 Wall Wood 182 0.088 315 90 X R-13 Wall .13.20.16 Guestroom 131 Roof Wood 473 0.051 0 0 X I R-19 Roof R.19.2x8.16 Guestroom 132 Wall Wood 19 0.088 225 90 X I JR-13Wall .13.2x4.16 Guestroom 133 Wall Wood 182 0.088 135 90 X I JR-13Wall .13.20.16 Guestroom 134 Roof Wood 453 0.051 0 0 X I I R-19 Roof R.19.2x8.16 Guestroom 135 all[Wood 182 0.088 315 90 X11 JR-13WaH .13.20.16 Guestroom 136 Roof Wood 453 1 0.051 0 0 R-19 Roof R.19.2xB.16 Guestroom 137 Wall Wood 182 0.088 135 R-13 Wall .13.20.16 Guestroom 138 Roof Wood 453 0.051 0 0 X I I I R-19 Roof R.19.2x8.16 Guestroom 139 Wall Wood 182 0.088 315 90 R-13 Wall .13.2x4.16 Guestroom 140 Roof Wood 459 0.051 0 0 X R-19 Roof R.19.W.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing Check box if Buikfing is- 100,000 sgft of CFA and- 10,000 sqft vertical glazing then NFRC Certification is required. Follow NFRC 100-SR Procedures and submit NFRC Label Certificate Form_ # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 91 Window 46 1.040 180 0.63 Sin le NonMtl Tinted Default uestroom 92 Window 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroorn 93 Window 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroom 94 Window 46 1.040 180 0.63 Single NonMtl Tinted Default uestroom 95 Window 46 1.040 180 0.63 Single NonMtl Tinted Default 3uestroorn 96 indow 46 1.040 0 0.63 Single NonMtl Tinted Default 3uestroorn 97 Window 46 1.040 135 0.63 Single NonMtl Tinted Default uestroom 98 Window 46 1.040 135 0.63 Sin le NonMtl Tinted Default uestroom 99 Window 46 1.040 135 0.63 Single NonMtl Tinted Default 3uestroorn 100 Window 46 1.040 315 0.63 Single NonMt1 Tinted Default uestroom 101 Window 46 1.040 315 0.63 Single NonMtl Tinted Default Ouestroom 102 Window 46 1 1.040 135 0.63 Si le NonMtl Tinted Default uestroom 103 Window 1.040 315 0.63 Single NonMtl Tinted Default uestroom 104 indow 1.040 135 0.63 Single NonMtl Tinted Default uestroom 105 indow E46: 1.040 315 0.63 Single NonMtl Tinted Default uestroom EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 91 None 0.76 92 None 0.76 93 None 0.76 94 None 0.76 95 None 0.76 96 None 0.76 97 None 0.76 98 None 0.76 99 None 0.76 100 None 0.76 101 None 0.76 102 None 0.76 103 None 0.76 104 None 0.76 105 None 0.76 Run Initiation Time: 01/ 2105 07:39: 8 Run Code: 1055"358 EnergyPro 3.1 By EnergySoff User Number. 5863 Job Number: 040M Page: 19 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location I Comments 1141 all Wood 106 0.088 135 90 X R-13 Wall .13.2x4.16 Guestroom 142 Roof Wood 405 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 143 all Wood 69 0.088 315 90 X R-13 Wall .13.2x4.16 Guestroom 144 all Wood 68 0.088 225 90 R-13 Wall .13.2x4.16 Guestroom 145 Roof Wood 486 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 146 all Wood 19 0.088 135 90 X R-13 Wall .13.2x4.16 Guestroom 147 Wall Wood 201 0.088 45 90 R-13 Wall .13.2x4.16 Guestroom 148 Roof Wood 527 0.051 0 0 X1 I R-19 Roof R.19.2x8.16 Guestroom 1149IWall Wood 182 0.088 225 90 X1 JR-13Wall .13.2x4.16 Guestroom 150 Roof Wood 554 0.051 0 0 X I I R-19 Roof R.19.2x8.16 Guestroom 151 Wall Wood 19 0.088 315 90 X I JR-13Wall .13.2x4.16 Guestroom 152 Wall Wood 211 0.088 45 90 X I JR-13Wall 132x4.16 Guestroom 153 Roof Wood 654 0.051 0 0 X I I R-19 Roof R.192x8.16 Guestroom 154 Wall Wood 19 0.088 315 90 X I JR-13Wall .132x4.16 Guestroom 155 Wall Wood 211 0.088 225 90 X1 JR-13Wall .1320.16 Guestroom 156 Roof Wood 726 0.051 0 0 X RA Roof R.19.2x8.16 Guestroom 157 Wall ood 228 0.088 225 90 X R-13 Wall .132x4.16 Guestroom 158 Roof Wood 657 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 159 Wall ood 95 0.088 315 90 R-13 Wall .13.2x4.16 Guestroom 160 Wall Wood 118 0.088 45 90 X R-13 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing Check box if Building is - 100,000 sgft of CFA and - 10,000 sqft vertical glazing then NFRC Certification is required. Follow NFRC 100-SB Procedures and submit NFRC Label Certificate Form_ # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location I Comments 106 Window 7 1.040 135 0.63 Single NonMtl Tinted Default uestroom 107 Window 28 1.040 225 0.63 Si le NonMtl Tinted Default 3uestroom 108 indow 46 1.040 45 0.63 Sin le NonWl Tinted Default 3uestroom 109 indow 46 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 110 Window 46 1.040 45 0.63 Single NonMtl Tinted Default 3uestroom 111 Window 46 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 112 indow 46 1.040 45 0.63 Single NonMtl Tinted Default 3uestroom 113 indow 46 1.040 45 0.63 Sin le NonMtl Tinted Default 3uestmom 114 indow 46 1.040 225 0.63 Si le NonMtl Tinted Default 3uestroom 115 Window 46 1.040 225 0.63 Single NonMtl Tinted Default 3uestroom 116 Window 7 1.040 315 0.63 Single NonMU Tinted Default uestroom 117 Window 42 1.040 225 0.63 Sin le NonMtl Tinted Default uestroom 118 Window 1 7 1.040 135 0.63 Single NonMtl Tinted Default uestroom 119 Window 42 1.040 225 0.63 Single NonMtl Tinted Default uestroom 120 indow 18 1.040 315 0.63 Single NonMtl Tinted Default uestroom EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 106 None 0.76 107 None 0.76 108 None 0.76 109 1 None 0.76 110 None 0.76 111 None 0.76 112 None 0.76 113 None 0.76 114 None 0.76 115 None 0.76 116 None 0.76 117 None 0.76 118 None 0.76 119 None 0.76 120 None 0.76 Run Initiation Time: 112105 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:20 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 FROJECT NAME I-Inmawnnri Suites Hotel DATE 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location I Comments 161 162 163 Roof Wall all Wood Wood Wood 657 95 118 0.051 0.088 0.088 0 135 45 0 90 X R-19 Roof R.19.2x8.16 R-13 Wall .13.2x4.16 R-13 Wall .13.2x4.16 Guestroom Guestroom Guestroom 164 165 Roof all Wood Wood 554 19 0.051 0.088 0 135 0 90 R-19 Roof R.19.2x8.16 R-13 Wall .13.2x4.16 Guestroom Guestroom 166 Wall ood 211 0.088 45 90 X R-13 Walt .13.2x4.16 Guestroom 167 168 Roof Wall Wood ood 654 19 0.051 0.088 0 135 0 90 X R-19 Roof R.19.2x8.16 R-13 Wall .13.2x4.16 Guestroom Guestroom 169 all ood 211 0.088 225 90 R-13 Wall Vq ?vA '161 Guestroom 170 Roof Wood 473 n rm 0 0 X R-19 Roof 11.19.2x8.16 Guestroom 171 Wall Wood 19 0.088 315 90 ILR-13 Wall .13.2x4.16 Guestroom 172 all ood 182 0.088 45 90 R-13 Wall 13.2x4.16 Guestroom 173 Roof Wood 527 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 174 all Wood 182 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom 175 Roof Wood 622 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 176 Wall Wood 69 0.088 315 90 R-13 Wall .13.2x4.16 Guestroom 177 all ood 167 0.088 225 90 R-13 Wall .13.2x4.16 Guestroom 178 Roof ood 622 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 179 all Wood 268 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 180 Wall ood 167 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES 1i .1--i ,+k- nJrar rcrt:firntinn is raniiirarl n Check boX it buming is >= iCP3,lAju sqn ui urr+ anu v,vw ayn .�....,a. y...�...y __._..---.-...- Cifn Accnmhltul r�la7�nn _ .. ..__.................�. ____ __� _..6�.A Mrnr• i -k-1 !`e.r:F Mtn Fnrm �•" # 121 122 """"•••-'-- ----- o LJ t'OIIOW Type indow Window tVYKI. 1W-J6 r(Uta.'uu�� Act. Azm. 135 315 miu auu�n- SHGC 0.63 0.63 Glazing Type Single Non&% Tinted Default Sin le NonMtl Tinted Default Location !Comments uestroom uestroom 123 indow r46 135 0.63 Sin le NonMtl Tinted Default uestroom 124 indow 135NonMtl Tinted Default uestroom 90 0.63 Si le NonMtl Tinted Default uestroom . 270 0.63 Single NonMtl Tinted Default uestroom 1125!Endow 46 1.040 90 0.63 Sin le NOnMtI Tinted Default uestroom 46 46 1.040 1.040 90 270 0.63 0.63 Sin le NonMtl Tinted Default Si le NonMtl Tinted Default uestroom uestroom indow 60 1.040 90 0.63 Sin le NonNHI Tinted Default uestroom 131 indow 60 1.040 90 0.63 Sin le NonMtl Tinted Default uestroom 132 Window 60 1.040 270 0.W Sin le NonMtl Tinted Default uestroom 133 Window 60 1.040 270 0.63 Sin to NonMtl Tinted Default uestroom 134 indow 1 30 1.040 90 0.63 Si le Nonh tl Tinted Default uestroom 135 indow 60 1.040 1 135 0.63 Sin le NonMtl Tinted Default uestroom EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H . LExt.RExt. Dist. Len. H t. Dist. Len. H t. 121 None 0.76 122 None 0.76 123 None 0.76 124 None 0.76 125 None 0.76 126 None 0.76 127 None 0.76 128 None 0.76 129 None 0.76 130 None 0.76 131 None 0.76 132 None 0.76 133 None 0.76 134 None 0.76 135 None 0.76 n Initiation Time: 1112105 07:39:18 Run Code: 110 358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: W88 Pa ge:21 of 126 JENVELOPE COMPLIANCE SUMMARY Performance ENV-1 - - - DATE PROJECT NAME 2/28/2005 Homewood Suites Hotel - -- Solar Surface Framing Area U-Fac. Act. Azm. Gains Tilt YIN Form 3 Reference Location t Comments # Type Type 0 X R-19 Roof R.19.2x8.16 Guestroom 81 Roof o0d 475 0.051 0 45 90 R-13 Wall .13.2x4.16 G,—troom 82 all ood 29 106 0.088 0.088 315 90 X R-13 Wall .13.2x4.16 Guestroom 83 Wall ood 0.051 0 0 R-19 Roof R.19.2x8.16 Guestroom 84 Roof Wood 453 182 0.088 135 90 R-13 WaN .13.2x4.16 Guestroom 85 Wall ood 0 0 0 R-19 Roof R.19.2x8.16 Guestroom 86 Roof Wood 453 0.051 0.088 315 90 R-13 Wall 13.2x4.16 Guestroom 87 Wall ood 182 0 0 X R-13 Roof R.19.2x8.16 Guestroom 188 Roof Wood 453 0.051 0.088 135 90 R-13 Wall 12x8.1 16 Guestroom 189 all ood 182 0 0 X R-19 Roof R.192x8.16 Guestroom 190 Roof ood 545 0.051 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 191 Wall ood 119 144 0.088 90 90 X R-13 Wail .13.2x4.16 Guestroom 192 all 193 Wall Wood Wood 182 0.088 270 90 R-13 Wall 13.2x4.16 R-19 Roof R.19.2x8.16 Guestroom Guestroom 194 Roof Wood 473 0.051 0 0 X g0 R-13 Wall 13.2x4.16 Guestroom 195 all Wood 182 0.088 0 0 X R-19 Roof ft.19.2x8.16 Guestroom 196 Roof ood 473 154 0.051 0.088 270 90 X R-13 Wall 13.2x4.16 Guestroom 197 all ood 0 0 R-19 Roof R.19.Dc8.16 Guestroom 198 Roof ood 473 0.051 0 R-13 Wall .13.2x4.16 Guestroom 199 Wall ood 0 0� 0.088 90 90 R-13 Wall .13.2x4.16 Guestroom 200 all ood 184 FENESTRATION SURFACES >= ft vertical CFA and 10,000 sq glazing then NFRC Certification is required. 9 n9 Site Assembled Glazing Check box if Building is — 100,000 sgft of Follow NFRC 100-SB Procedures and submit NFRC Label Certificate Form. Act. Azm. SHGC Glazing Type Location I Comments # Type Area U-Fac. 315 0.63 Sin le NonMtl Tinted Default uestroom 136 indow 60 1.040 1.040 135 0.63 Sin le NonMtl Tinted Default uestroom 137 indow _ _ 60 rIn 1 n4n 135 0.63 Sin Ie NonMtI Tinted Default uestroom 1.040 1 0.63 0.63 # I Exterior Shade Type ISHGCj Hgt. Wd. 0.7s 148 None 0. 149 1 None 0. 0. overhang _ Left Fin w Right Fin Run initiation 1lmPage22 of 126 User Number: 5863 Job Number: 04088 3.1 By EnergySoft - ENVELOPE COMPLIANCE SUMMARY Performance ENVA (PROJECT NAME - - - - - - - - - DATE Nnmcwnnri SuitAs Hotel 2/28/2005 OPAQUE SURFACES Solar Surface Framing Act. Gains # Type Type Area U-Fac. Azm. Tilt YIN Form 3 Reference Location / Comments 201 all ood 238 0.088 90 90 X R-13 Wa11 .13.2x4.16 Guestroom 202 all ood 184 0.088 180 90 R-13 Wall M.13.2x4.16 Guestroom 203 all ood 150 0.088 180 90 X11 I R-13 Wall .13.2x4.16 Guestroom 204 all ood 38 0.088 180 90 x1l I R-13 Wall .13.2x4.16 Guestroom 205 Wall Wood 148 0.088 270 90 R-13 Wall .13.2m.16 m 206 all ood 38 0-088 180 90 R-13 Wall .13.2x4.16 m 207 Wall Wood 184 0.088 90 90 R-13 Wall .13.2x4.16 m 208 Wall ood 38 0.088 0 90 X R-13 Wall .132x4.16 m NGuestroom 209 all ood 184 0.088 90 90 R-13 Wall .13.2x4.16om210 all Wood 38 0.088 90 90 X R-13Wall .13.2x4.16om211 all ood 204 0.088 0 90 R-13 Wall .13.2x4.16om212 all ood 38 0.088 270 90 R-13Wall .13.2x4.16om 213 Wall ood 182 0.088 0 90 x R-13 Wall 13.2x4.16 Guestroom 214 Walt Wood 182 0.088 0 90 X IRA all .13.2x4.16 Guestroom 215 all Wood 182 0.088 180 90 R-13 Wall (W.13.2x4.161 Guestroom 216 Wa11 Wood 1 182 0.088 180 90 R-13 Wan{ .13.2x4.16 Guestroom 217 Wall ood 182 0.088 0 90 X R-13 Wall .132(4.16 Guestroom 218 Wall Wood 38 0.088 90 90 R-13 Wall .13.2x4.16 Guestroom 219 Wall ood 182 0.088 0 90 R-13 Wall 0A1 13.2x4.I AlGuestroom 220 Wall ood 38 0.088 90 90 X11 I R-13 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES - nn nn __4b._.;__1 1,,„,.,,+I,.n KwDr` r`ortiriratinn is reni ired- n CheCk boX it Building is >= 1uu,uw sgii of %,rn anu lvl v �41..��wo. y..+.-.,.y ....... _._.._--•-• Si- Assembled Glazinn - __ ..-- _ _ _ �_____ __� _..�_a kicnf, i . &L ] r`e 4;rn to C7 r # 151 _.. -.__. IJ Type indow t-0110W NY Area 60 KG 1W-a0 U-Fac. 1-040 rrOceuuleq Act. Azm. 135 a..0 auun- SHGC 0.63 111 Glazing Type Single NonMtl Tinted Default - Location / Comments uestroom 152 Window 60 1.040 315 0.63 Single NonMtl Tinted Default 3uestroom 153 Window 60 1.040 315 0.63 Sin le NonMtl Tinted Default 3uestroorn 154Window 60 1.040 315 0.63 Single NonMtl Tinted Default 3uestroorn 155 indow 60 1,040 180 0.63 Single NonMtl Tinted Default uestroom 156 Window 60 1-040 180 0.63 Single NonMtl Tinted Default uestroom 157 indow 60 1.040 0 0.63 Single NonMtl Tinted Default uestroom 158 159 Window indow 60 60 1.040 1.040 0 180 0.63 0.63 Si le NonMtl Tinted Default Single NonMtl Tinted Default uestroom uestroom 160 indow 60 1.040 180 0.63 Sin le NonMtl Tinted Default uestroom 161 indow 60 1.040 0 0.63 Defaultjuestroorn162Window 60 1.040 0 0.63 d Defaultoom163 indow 60 1.040 0 0.63 asingleLNonhmlTintedd d Defaultoom164 indow 60 1.040 0 0.63 d Defaultoom165 indow 40 1.040 270 0.63 d Defaultoom EXTERIOR ## SHADING Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. H t. Right Fin Dist. Len. H t. 151 None 0.76 152 153 154 None None None 0.76 0.76 0.76 155 None 0.76 156 None 0.76 157 None 0.76 158 None 0.76 159 None 0.76 160 161 None None 0.76 0.76 162 163 None None 0.76 0.76 164 None 0.76 165 None 0.76 Run Initiation Time: 0111210 07:39:18 RunCode-, 11055 358 EnergyPro 3.1 By EnergySoft User Number: 5863 .fob Number: 04088 Page:23 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments 221 Wall ood 182 0.088 180 90 R-13 Wail .13.2x4.16 Guestroom 222 all Wood 38 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom 223 all Wood 184 0.088 180 90 X R-13 Wall .13.2x4.16 Guestroom 224 all Wood 38 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom 225 all Wood 184 0.088 0 90 R-13 Wall .13.2x4.16 Guestroom 226 Wall Wood 19 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom 227 all Wood 182 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 228 all Wood 19 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom 229 all Wood 182 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 230 Wall Wood 19 0.088 45 1 90 x1l 1R-13Wall .13.20.16 Guestroom 231 Wall Wood 182 0.088M315 90 R-13 Wall .13.20.16 Guestroom 232 all Wood 19 0.08890 X R-13 Wall .13.20.16 Guestroom 233 Wall -Wood 182 0.08890 R-13 Wall .13.2x4.16 Guestroom 234 Wall Wood 19 0.088 R-13 Wall .13.20.16 Guestroom 235 all Wood 182 0.08890 R-13 Wall .13.2x4.16 Guestroom 236 Wall Wood 182 0.08890 X R-13 Wall .13.20.16 Guestroom 237 all Wood 182 0.08890 X R-13 Wall .13.20.16 Guestroom allWood 106 0.088 135 90 R-13 Wall .13.20.16 Guestroom all ood 182 0.088 315 90 R-13Wall .13.2x4.16 Guestroomall g Wood 69 0.088 135 90 X R-13 Wall .13.20.16 GuestroomESTRATION SURFACES Site Assembled Glazing n Check box if Building is— 100,000 sgtt of (A -A and — 1u,uuu sgtt verucat glazing men rvrm� t,emncauon Is requneu. r..n,.... uror �m erz o.....o.a..� 0.,.1 cnhmh AIFRC I �hel rertifirafa Fnrm # I Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments 166 indow 60 1.040 90 0.63 Single NonMd Tinted Default Guestroorn EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. Hat. 166 None 0.76 Run Initiation Time-, 01112105 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:24 of 126 (ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 (PROJECT NAME - - - - DATE I i Homewood Suites Hotel 2/28/2005 -i OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location ! Comments 241 Wall Wood 88 0.088 225 90 x R-13 Wall .13.2x4.16 Guestroom 242 Wall Wood 19 0.088 135 90 X11 IR-13Wall .13.2x4.16 Guestroom 243 Wall Wood 201 0.088 45 90 X11 IR-13Wall .13.2x4.16 Guestroom 244 Wall Wood 182 0.088 225 90 x1l I R-13 Wall .13.2x4.16 Guestroom 245 Wall Wood 19 0.088 315 90 x1l R-13 Wall .13.2x4.16 Guestroom 246 Wall Wood 211 0.088 45 90 X11 R-13 Wall .13.2x4.16 Guestroom 247 Wall Wood 19 0.088 315 90 R-13 Wall .13.2x4.16 Guestroom 248 Wall Wood 211 0.088 225 90 x1l R-13 Wal{ .13.2x4.16 Guestroom 249 Wall Wood 19 0.058 315 90 x1l R-13 Wall .13.2x4.16 Guestroom 250 Wall Wood 182 0.088 45 90 R-13 Wall .13.2x4.16 Guestroom 251 Wall Wood 19 0.088 135 90 X1 F1 R-13 Wall .13.2x4.16 Guestroom 252 Wall Wood 211 0.088 1 45 90 R-13 Wall .13.2x4.16 Guestroom 253 Wall Wood 19 0.088 1 135 90 x1l I R-13 Wall .132x4.16 Guestroom 254 Wall lWood 211 0.088 225 90 x1l I R-13 Wall .13.2x4.16 Guestroom 255 Wall NVood 182 0.088 225 90 X11 I R-13 Wall .13.2x4.16 Guestroom 256 Wall wow 69 0.W8 315 90 X R-13 Wall .13.2x4A6 Guestroom 257 Wall Wood 167 0.088 225 90 X R-13 Wall .13.2x4.16 Guestroom 258 Wall Wood 268 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 259 Wall Wood- 167 0.088 225 90 R-13 Wall .13.2x4.16 Guestroom 260 Wall Wood 29 0.088 45 90 X R-13 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing Check box if Building is >= 100,000 sgft of CFA and >= 10,000 sgft vertical glazing then NFRC Certification is required. Follow NFRC- inn-S11 Prnoedurec and submit NFRC label Certificate Form. # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hat. LExLRExt. Dist. Len. Hqt. Dist. Len. H t. Run Initiation Time: 01112105 0 :3918 Run Code: 11055443F8 EnergyPro 3.1 By EnergySofl User Number. 5863 Job Number. 04088 Page:25 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tift Y/N Form 3 Reference Location / Comments 261 all Wood 105 0.088 315 90 R-13 Wall .13.2x4.1§ Guestroom 262 Wall Wood 182 0.088 135 90 X11 I R-13 Wall .13.2x4.16 Guestroom 263 Wall Wood 182 0.088 315 90 X11 I R-13 Wall .13.2x4.16 Guestroom 264 Wall Wood 182 0.088 135 90 x1l I R-13 Wall .132 4.16 Guestroom 265 Wall Wood 119 0.088 135 90 x I R-13 Wall .13.2x4.16 Guestroom 266 Wall Wood 144 0.088 90 90 X I R-13 Walt .13.2x4.16 Guestroom 267 all Wood 182 0.088 270 90 R-13 Wall .13.20.16 Guestroom 2 all ood 182 0.088 90 90 X I R-13 Wall .13.2x4.16 Guestroom 269 Wall tWood 86 0.088 0 90 X I R-13 Wall .1320.16 Guestroom 270 Wall Wood 184 0.088 90 90 X I R-13 Wall .13.2x4.16 Guestroom 271 Wall Wood 184 0.088 270 90 x I I R-13 Wall .13.2x4.16 Guestroom 272 Wall Wood 204 0.088 90 90 x1l I R-13 Wail .132x4.16 Guestroom 273 Wall Wood 204 0.088 90 90 x1l I R-13 Wall .13.2x4.16 Guestroom 274 all Wood 204 0.088 270 90 X I I R-13 Wall .13.2x4.16 Guestroom 275 Wall Wood 204 0.088 270 90 X I I R-13 Wall .13.2x4.16 Guestroom 276 Wall odd 179 0.W8 90 90 X R-13 Wall .13.2x4.16 Guestroom 277 Wall 1136 0.088 135 90 X I JR-113Wall .13.2x4.16 Guestroom 278 Wall NVood 1204 1 0.088 315 90 R-13 Wall .132x4.16 Guestroom 279 Wall 1204 1 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 280 Wall Wood 1204 1 0.088 135 90 X R-13 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing n Check box if Building is— 100,000 sqft of CFA and >= 1o,uuu sgttvertical glazing then NFKC Certiticatwd. n is require Fnl1— NFRr_ IrVLCR Prnr iiirP and Ciihmit NFRC: I ahPl C:PrtifiratP From # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location ! Comments EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgt. LExt.RExt. Dist. Len. H t. Dist. Len. H t. Run Initiation Time; 01112105 07:39:18 Run Code- 110554435 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:26 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV—' PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt YIN Form 3 Reference Location 1 Comments 281 Wall Wood 330 0.088 135 90 R-13 Wall .13.2x4.16 Guestroom 282 Wall Wood 132 0.088 225 90 X I IR-13Wall .13.2x4.16 Guestroom 283 Wall Wood 132 0.088 225 90 X I IR-13Wall .13.2x4.16 Guestroom 284 Wall Wood 204 0.088 225 90 x I I R-13 Wall .13.2x4.16 Guestroom 285 Wall Wood 204 0.088 225 90 x I I R-13 Wall .13.2x4.16 Guestroom 286 Wall Wood 88 0.088 225 90 X I JR-13Wall .13.2x4.16 Guestroom 12871Wall lWood 69 0.088 1 135 1 90 R-13 Wall .13.2x4.16 Guestroom 288 Wall Wood 215 0.088 1 45 1 90 Al JR-13Wa# .13.2x4.1 Guestroom 289 Wall Wood 204 0.088 135 90 x I R-13 Wall .13.2x4.16 Guestroom 290 Wall Wood 204 0.088 315 90 X I R-13 Wall .13.2x4.16 Guestroom 291 Wall Wood 204 0.088 315 90 x IR-13Wall .13.2x4.16 Guestroom 292 Wall Wood 204 0.088 135 90 X R-13 Wall .13.2x4.16 Guestroom 293 Wall lWood 1204 0.088 135 90 RA Wall .13.2x4.16 Guestroom 294 Wall lWood 220 0.088 45 90 X R-13 Wall .13.2x4.1 Guestroom 295 Wall[Wood 204 0.088 135 90 x I R-13 Wall .13.2x4.16 Guestroom 296 Wall'Wood 204 0.088 315 90 Xjj R-13 WaN .13.2x4.16 Guestroom 297 Wall Wood 204 0.088 315 90 Wall .13.2x4.16 Guestroom 298 all Wood 204 0.088 315 90Wall 132x416 Guestroom299 Wall ood 204 0.088 180 90Wall LRA 132x416 Guestroom300 all ood 44 0.088 90 90 Wall .13.2x4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing U UnecK oox n Duuurny rs rw,vw "IL VI l,VM 011 -- I ', a4.L YGnwa1 y--j u.cn - nv vc.uuv.+uvn w . y.n .. Follow NFRC 100-SB Procedures and submit NFRC Label Certificate Form. # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. Hgt. Dist. Len. H t. Run Initiation Time: 01/12105 07:39:1Run Code: 1105M435B EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number. 04088 Page:27 of 126 ENVELOPE COMPLIANCE SUMMARY Performance ENV-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 OPAQUE SURFACES # Surface Type Framing Type Area U-Fac. Act. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments 301 Wall'Wood 204 0.088 180 1 90 X R-13 Wall .13.2x4.16 Guestroom 302 Wall Wood 275 0.088 270 1 90 X I IR-13Wall .13.2416 Guestroom 303 all Wood 204 0.088 0 90 X I IR-13Wall .13.2x4.16 Guestroom all ood 275 0.088 270 90 R-13 Wall .13.2x4.16 Guestroom all Wood 204 0.088 0 90 R-13 Wall .13.24.16 Guestroom all Wood 44 0.088 90 90 X R-13 Wall .13.2x4.16 Guestroom r all ood 204 0.088 180 90 R-13 Wall .13.2x4.16 Guestroom Wall ood 204 0.088 180 90 X R-13 Wal! .13.2x4.16 Guestroom Wall Wood 204 0.088 0 90 X R-13 Wall .13.2x4.16 Guestroom 310 Wall Wood 204 0.088 0 90 X R-13 Wall .13.2x4.16 Guestroom 311 Wall Wood 204 0.088 0 90 x I IR-13Wall .13.2x4.16 Guestroom 312 Wall Wood 44 0.088 270 90 X I I R-13 Wall .13.2x4.16 Guestroom 313 Wall Wood 325 0.088 0 90 X R-13 Wall .13.2x4.16 Guestroom 314 Wall Wood 264 0.088 90 90 X R-13 Wall .13.2x4.16 Guestroom 315 Wall Wood 146 0.088 270 90 X R-13 Wall .13.2x4.16 Guestroom 316 al{ Wood 38 0.088 180 90 X R-13 Wall .13.2x4.16 Guestroom 317 Wall Wood 204 0.088 90 90 X R-13 Wall .13.2x4.16 Guestroom 318 Wall Wood 44 0.088 0 90 R-13 Wall .13.2X4.16 Guestroom FENESTRATION SURFACES Site Assembled Glazing Check box if Building is — 100,000 sqft of CFA and — 10,000 sqft vertical glazing then NFRC Certification is required. Follow NFRC 1M.RR Procedures and submit NFRC Label Certificate Form. # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. Hgj. LExt.RExt. Dist. Len. Hgt. Dist. Len. H t. Run niti ti n Time: 01112105 07:3 8 Run Code: 1105544358 EnergyPro 3.1 By Energysoft User Number: 5863 Job Number: 04088 Page:28 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME I DATE Homewood Suites Hotel 2/28/2005 IINSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Lumi% ire +Ballast Code LUMINAIRE DESCRIPTION PE RIPTION f # watts Lamp DESCRIPTION # Lam # Watts Total Watts F126,w Com actFluorescent Tri le 4 Pin CFM 26W/GX2 -3 1 26 Ma netic Standard 1. 394 37.0 1457Fluorescent T8 Elec F32T8 32 Electronic 1-0 6 32 0 192 2 13w Com ct Fluorescent Twin 2 Pin CFT13W/GX23 2 Standard 2. 98 34.0 3.33 2 2 ft Fluorescent T8 Elec F17T8 2 t3ac ic 1. 8 33.0 264 2 2ft U-Tube T8 Elec 2 nic 1.0 61 62.0 3 782 2 4 ft Fluorescent T8 Elec F32T8 32 Electronic 1. 18 62.0 1 116 3 4 ft Fluorescent T8 Elec F32T8 332 Electronic 1.0 16 93.0 1 488 Subtotal from this Page Lighting Schedule on Plans Shows Exterior Lighting Meets Total Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of 630(c) Less Control Credit Watts (From LTG) 24 752 24,752 1,238 U Control Requirements of 631(0 Adjusted Actual Watts L 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO. FIELD CONTROLS FOR CREDIT 71 CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dirrxning, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES Corridor 73 Automatic Time Switch 2 Corridor 73 Automatic Time Switch 5 Hotel Storage Automatic Time Switch 4 Corridor 114 Automatic Time Switch 5 NOTES TO FIELD - For gu-ildinci Department Use Only J Run Initiation Time: 01112/05 07:39:13 Run code: 77U554435t3 EnergvPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:29 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 NAME DATE Homewood Suites Hotel 1 2/28/20051 INSTALLED LIGHTING SCHEDULE 1 AMPS I BALLASTS I Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts L nnp DESCRIPTION # Lamp # Ballast watts Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page L 0 Meets Total 24,752 Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of WO(c) Less Control Credit Watts (From LTG-3) 1,238 ❑ Control Requirements of 931(1) Adjusted Actual Watts 23,514 MANDATORY TOMAT C CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED ;NOTE.F0 : CONTROL LOCATION (Room # or Dwa. #1 Corridor 114 Elevator Lobbv 110 Elec EauiD 109 CONTROL IDENTIFICATION CONTROL TYPE {Occupant, Daylight, Dbwfdng, etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch 14 NOTE TO EnerovPro 3.1 By EnermSo t User Number. 580 Job Number: 04088 Page:30 of 126 1 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 (PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 INSTALLED LIGHTING SCHEDULE LAMPS I BALLASTS I Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # P� Lamp DESCRIPTION # Lam + Ballast Total Watts # watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 24,752 Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of 030(c) [—]Control Requirements of 431(1) Less Control Credit Watts (From LTG3) 1,238 Adjusted Actual Wafts Dig MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE IUtTi<70 (Room #) IDENTIFICATION (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED FIEL- LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 STALLED LIGHTING SCHEDULE LAMPS I BALLASTS 11Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts mP DESCRIPTION # Lam + # Ballast Watts Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 24,752 ❑ Efficacy and Control Requirement of 130(c) Portable Lighting (From LTG-1) Less Control Credit Watts (From LTG3) 1,238 ❑ Control Requirements of 431(f) Adjusted Actual Watts 23,514 IMANDATORY AUTOMATICCONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TypE # OF LUMINAIRES Corridor 97/99 Automatic Time Switch 19 Corridor 93 Right Automatic Time Switch 3 Corridor 93 Right Automatic Time Switch 13 Corridor 105 Automatic Time Switch 6 NOTES TO FIELD - For Building De artment se Onl Run Initiation Time: 01 12105 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:32 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 NAME DATE Homewood Suites Hotel _ _ 1 2/28/2005 IINSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # � DESCRIPTION # Lam +Ballast # Waits Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of WO(c) Less Control Credit Watts (From LTG-3) ❑ Control Requirements of 431(f) Adiusted Actual Watts 24,752 1,238 23,514 LLl1s1l.L'ls U S - - o * ri - o CONTROL LOCATION (Room #) CONTROL. IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED N?TE;Tq> FIELD . CONTROL LOCATION (Room # or Dwg. #) Corridor 105 Corridor 93 Left Corridor 93 Left Elevator Lobbv 103 CONTROL IDENTIFICATION CONTROLTYPE (Occupant, Daylight, Dimming, etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch 19 12 EnergyPro 3.1 By Enerff4oft User Number: SSW Job Number:04088 Page:33 of 126 1 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 NAME DATE Homewood Suites Hotel I 2/28/2005___J [INSTALLED LIGHTING SCHEDULE LAMPS I BALLASTS I Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # watts �P DESCRIPTION # �'#Wafts Lamp Banast Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 24,752 ❑ L �J Efficacy and Control Requirement of WO(c)Portable Lighting (From LTG-1) Less Control Credit Watts (From LTG3) 1,238 ❑ Control Requirements of 431(f) Adjusted Actual Watts 23,514 MANDATORYATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Tirne Switch, Exterior, etc.) SPACE CONTROLLED NOTt.:7 - FIELD CONTROL LOCATION (Room # or Dwg. #) Elec Equip 102 Corridor 78 Corridor 78 Condor 74 ON IDENTIFICATION CONTROL CONTROL TYPE (Occupwit, Daylight, Dimming. etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch 19 EneravPro 3.1 By EneravSoft User Number. 580 Job Number: 04088 Paoe:34 of 126 1 jLIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 INSTALLED LIGHTING SCHEDULE r AMPS I BALLASTS I Luminaire Code LUMINAIRE DESCRIPTION TYPE - DESCRIPTION # watts DESCRIPTION # (Lamp + # uaiiast watts Total Watts Subtotal from this Page �J Lighting Schedule on Plans Shows Exterior lighting Meets Total 24,752 Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of 11530(c) Less Control Credit Watts (From LTG3) 1,238 ❑ Control Requirements of 431(f) 23,514 Adjusted Actual Watts MANDATORY UTO AT CO CONTROL TYPE (Auto Tune Switch, Exterior, etc.) SPACE CONTROLLED NOTE Tfl:' FIEI-0 CONTROL LOCATION (Room #) CONTROL IDENTIFICATION [CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dirrnting, etc.) S CONTROLLEDNOTE TO FIELD TYPE # OF LUMINAIRES Corridor 74 Automatic Time Switch 12 Elevator Lobby 76 Automatic Time Switch 1 Elec Equip 75 Automatic Time Switch 1 Corridor 49 Automatic Time Switch 6 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01112105 07:39:18 Run Code: 1105M4358 EnergyPro 31 By EnergyW User Number 5863 Job Number: 04088 Page:35 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel I 2/28/2005 INSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION it Watts Lame DESCRIPTION # Lam + # Ballast Watts Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total ❑ Efficacy and Control Requirement of S30(c) Portable Lighting (From LTG-1) Less Control Credit Watts (From LTG3) [:]Control Requirements of 631(1) Adiusted Actual Watts �Q 1,238 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD CONTROLS FOR CREDIT CONTROL LOCATION CONTROL (Room # or Dwg. #) IDENTIFICATION Corridor 49 Corridor 18 Corridor 18 Elevator Lobby 47 CONTROL TYPE (Occupant, Daylight, Dimming, etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch LUMINAIRES CONTROLLED TYPE # OF LUMINAIRES 19 5 12 1 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12/05 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:36 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 RN -STALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMIIdA1RE DESCRIPTION TYPE DESCRIPTION # Watts �p DESCRIPTION # Lam + # Ballast Watts Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total r--1 Portable Lighting (From LTG-1) 24,752 �0 " Efficacy and Control Requirement of §W(c) Less Control Credit Watts (From LTG3) E1,238 ❑ Control Requirements of 631(f) Adjusted Actual Watts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD CONTROL LOCATION (Room # or Dwg. #) Elevator Equip 46 Elevator Lobby 54 Elevator Equip 53 Ice 52 CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch 3.1 By EnergySoft user Number: 5863 Job Number: 04088 Pege:37 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 INSTALLED LIGHTING SCHEDULE I AMPS I RA LASTS p Luminaire Code LUMINAIRE DESCRIPTION TYPE - DESCRIPTION # Per LamP DESCRIPTION # Lam + # Banast Watts Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page L 01 Meets Total 24,752 Portable Lighting (From LTG-1) �0 ❑ Efficacy and Control Requirement of 630(c) Less Control Credit Watts (From LTG3) 1,238 ❑ Control Requirements of 431(f) Adjusted Actual Watts 23,514 MANDATORY TO I O O S CONTROL LOCATION (Room #) CONTROL LOCATION (Room # or Dwg. #) Dome Corridor Corridor 51 Corridor 51 Corridor 80 CONTROL IDENTIFICATION Automatic Time Time Switch Automatic Time Switch Automatic Time Switch 21 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12/05 07:39:18 Run Code: 11 055W58 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:38 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/20-71 05 INS ALLED LIGHTING SCHEDULE eivac BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp DESCRIPTION # (Lamp+ # tsanasl Watts Total Watts Subtotal from this Page I 0� Lighting Schedule on Plans Shows Exterior Lighting Meets Total 24,752 Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of S30(c) Less Control Credit Watts (From LTG-3) 1,238 ❑ Control Requirements of 531(f) Adjusted Actual Watts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dirruning, etc.) LUMINAIRES CONTROLLED —NOTE TO FIELD TYPE # OF LUMINAIRES Corridor 80 Automatic Time Switch 21 Corridor 85,87 Automatic Time Switch 5 Corridor 85,87 Automatic Time Switch 14 Comdor 71 Automatic Time Switch 5 NOTES TO FIELD - For Buildinci Department Use Onl Run Initiation Time: 01112/05 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:39 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE L Homewood Suites Hotel _ _ 2/28/2005 STALLED LIGHTING SCHEDULE LAMPS BALLASTS --tit Ltmtinaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # watts Lamp DESCRIPTION Lam + Ballast Watts Total Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page �� Meets Total � 24,752 F---1 Portable Lighting (From LTG-1) �— 0 U Efficacy and Control Requirement of e30(c) Less Control Credit Watts (From LTG-3) 1,238 ❑ Control Requirements of 431(f) Adjusted Actual Watts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE (Room #) IDENTIFICATION (Auto row Switch, Exterior, etc.) CONTROLS FOR CREDIT CONTROL LOCATION CONTROL CONTROLTYPE S CONTROLLED (Room # or Dwg. #) IDENTIFICATION (Occupant, Daylight, Dirruning, etc.) TYPE # OF LUMINAIRES z; FIFA D'>> Corridor 71 Automatic Time Switch 19 Corridor 67 Automatic Time Switch 3 Corridor 67 Automatic Time Switch 13 Admin Automatic Time Switch 3 EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number: 04088 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel I 2/28/2005 __j INSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp DESCRIPTION # Lam +Ballast # Watts Total Watts Subtotal from this Page Lighting Schedule on Plans Shows Exterior Lighting Total Meets Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of §30(c) Less Control Credit Watts (From LTG-3) ❑ Control Requirements of 631(f) Adjusted Actual Watts �❑ 24,752 1,238 F 23,514 AAAw1nATnoV AI -1r^RAAT1f• f-fIkITQnI C •, SPACE CONTROLLED NOTE TO FIELD CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES Convenience Store Automatic Time Switch 2 General Manager Automatic Time Switch 2 PBX Automatic Time Switch 1 PantL:d Automatic Time Switch 15 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01112/05 07:39.18 Run Code: 11055U358 EnergyPro 3.1 By EnergySoff User Number: 5863 Job Number: 04OW Page:41 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG7-1 r!�!! T NAME DATE Homewood Suites Hotel 2/28/2005 IINSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Lam + Ballast Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # wa Lamp DESCRIPTION # Watts Total watts Subtotal from this Page Lighting Schedule on Plans Shows Exterior Lighting Total Meets Portable Lighting (From LTG-1) 24,752 Lf Efficacy and Control Requirement of 430(c) Less Control Credit Watts (From LTG3) 1,238 ❑ Control Requirements of 431(1) Adjusted Actual Watts 23,514 iRfiAK1r%A'r^0v Al IWWATIP rnkITPr1I C SPACE CONTROLLED NOTE TO FIELD CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Tone Switch, Exterior, etc.) ONTROLS FOR CREDIT CONTROL LOCATION (Roo # or Dwg. #) m CONTROL IDENTIFICATION CONTROL TYPE n (OccupaK Daylight, Dunning, etc.) MI NOTE TO FIELD TYPE # OF LUMINAIRES Food Prep Automatic Time Switch 4 Registration Automatic Time Switch 6 Registration Automatic Time Switch 2 El Sales Director Automatic Time Switch 2 NOTES TO FIELD - For Bujldjn Department Use Only Run Initiation Time: 01112105 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number. 04098 Page:42 of 126 IGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 NAME HnmPwnnri Suites Hotel INSTALLED LIGHTING SCHEDULE DATE 2/28/2005 r AUDe I Rat t ARTA I Luminaire — Code -- LUMINAIRE DESCRIPTION TYPE - DESCRIPTION # Waits p DESCRIPTION # Lam + # Ra-s watts Total Watts Subtotal from this Page 0� Lighting Schedule on Plans Shows Exterior Lighting Total Meets 24,752 Portable Lighting (From LTG-1) ❑ Efficacy and Control Requirement of WO(c) Less Control Credit Watts (From LTG3) 1,238 ❑ Control Requirements of 431(1) Adjusted Actual Watts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE NOTE TO (Room if) IDENTIFICATION (Auto Tmne Switch, Exterior, etc.) SPACE CONTROLLED FIB CONTROL LOCATION I I CONTROL (Room # or Dv IDENTIFICATION Work ATM Exec Center \Aedie.., 0-4 Automatic Time Switch I Automatic Time Switch 14 Automatic Time Swdch 2 Automatic Time Switch 1 14 NOTE TO W. NOTES TO FIELD - For Buildin-g De artment Use Only Run Initiation Time: 01112105 07:39:18 Run Code: 1105544358 EnergyPro 1 By Enernvsoft User Number: 5863 Job Number: 04088 Page:43 0(126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 __J (PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 INSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Lurrdnaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION #P Wars Per DESCRIPTION # Lam + # Ballast)Total Wafts Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total - Efficacy and Control Requirement of 530(c) Portable Lighting (From LTG-1) Less Control Credit Watts (From LTG3) � Control Requirements of 531(f) Adjusted Actual Watts IJ 24 752 1,238 23,514 MANDATORY AUTOMATIC CONTROLS 71 CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD C NTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) Lodge CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) LUMINAIRES CONTROLLED NOTE TO FIELD TYPE # OF LUMINAIRES Automatic Time Switch 34 Linen Storage Elec. 65 House KP Automatic Time Switch 1 Automatic Time Switch 4 Automatic Time Switch 1 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12105 07:39:18 Run Code: 11055"358 EneroPro 3.1 By EnergySoft User Number: 5863 Job Number. 04088 Page:44 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel _ _ 2/28/2005 INSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # watts Per �mP DESCRIPTION # Lam + Ballast Total Watts # Watts L Subtotal from this Page Lighting Schedule on Plans Shows Exterior Lighting Meets Total ❑ Efficacy and Control Requirement of 530(c) Portable Lighting (From LTG-1) ❑ Control Requirements of 931(1) Less Control Credit Watts (From LTG-3) Adjusted Actual Wafts 24,752 1,23a 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED .`>. ..................... CONTROL LOCATION (Room # or Dwg. #) House KP Corridor 55, 57, 60 Corridor 55.57.60 CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dinning, etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch 14 EnergyPro 3.1 By EnergySoft User Number. 580 Job Number: 04088 Page:45 of 126-1 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 STALLED LIGHTING SCHEDULE I AMPA I nAI I Acre II Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per �mP - -- - - DESCRIPTION # Lam + Ballast Total waft # Waits Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page �❑ Meets Total 24,752 �0❑ Efficacy and Control Requirement of 330(c) Portable Lighting (From LTG-1) ❑ Control Requirements of 431 (1) m Less Control Credit Watts (FroLTG-3) 1,238 Adjusted Actual Watts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room N) CONTROL IDENTIFICATION CONTROL TYPE (Auto Tinge Switch, Exterior, etc.) SPACE CONTROLLED NtTETr1 TIE D « LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel I 2/28/2005 NSTALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION I # lWatts Fer Lamp DESCRIPTION # Lam + Ballast)Total Watts # Watts Subtotal from this Page Lighting Schedule on Plans Shows Exterior Lighting Meets Total ❑ Efficacy and Control Requirement of ffi30(c) Portable Lighting (From LTG-1) ❑ Control Requirements of 531(1) Less Control Credit Watts (From LTG3) Adjusted Actual Watts ❑❑ 24,752 1,238 23,514 IMANDAT-O-RY--AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 STALLED LIGHTING SCHEDULE LAMPS I RAI I ASTS II Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per DESCRIPTION # kLamp+ Ballast Total Watts # Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 24,752 ❑ Efficacy and Control Requirement of S30(c) Portable Lighting (From LTG-1) Less Control Credit Watts (From LTG-3) 1,238 ❑ Control Requirements of 431(f) Adjusted Actual Watts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #l) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO. FIELD CONTROL LOCATION (Room # or Dwg. #) Women's Restroom Men's Restroom Men's Restroom Elevator Lobby 37 CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) Automatic Time Switch Automatic Time Switch Automatic Time Switch Automatic Time Switch N ..................... OT€ TO FIELD NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01112105 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number: 04088 Page:48 of 126 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 YKUJC(:1 NAMt DATE I Homewood Suites Hotel 1 2/28/2005 1 ON -STALLED LIGHTING SCHEDULE LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per �mP DESCRIPTION � Lam + Ballast Total Watts # Watts L Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 24 752 n Portable Lighting (From LTG-1) Fffirary and f :nnhiJ Ann..irc.nnn# ..i MN..� ❑ Control Requirements of 431(f) Less Control Credit Watts (From LTG3) 1,238 Adjusted Actual Watts 23,514 MANDATORY O A C CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED WTE Td FI.E.LL} LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG-1 PROJECT NAME DATE _ Homewood Suites HDATEotel - 2/28/2005 [INSTALLED LIGHTING SCHEDULE LUMINAIRE TYPE Code II DESCRIPTION DESCRIPTION Lurrunaire imp +Ballast r Total ,► l Watts Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 24,752 ❑ Efficacy and Control Requirement of 630(c) Portable Lighting (From LTG-1) ❑ Control Requirements of 431(Q Less Control Credit Watts (From LTG-3) 1,238 Adjusted Actual Wafts 23,514 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLEDIE>' NEET7 .................... CONTROL LOCATION (Room # or Dwg. #) Corridor 26 Board CONTROL IDENTIFICATION CONTROL TYPE Time Switch 13 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:50 of 126 LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG-1 PROJECT NAME DATE Homewood Suites Hotel I 2/28/2005 ROOM # OR ZONE ID DEFAULT f ft AREA SF TOTAL WATTS B X C TOTAL 0 0 n LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Description FIXT. FIXTURE (SF) AREAS (D x E) (C x E) TOTAL 0 0 TABLE 1 C - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # OR ZONE ID TOTAL AREA (SF) Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTALI 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA FROM TABLES A+1 1C ( ) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 0 0 Run Initiation Time: 01112105 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySofl User Number. 5863 Job Number: 04088 Page:51 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES ISYSTEM NAME I TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE MECHANICAL SYSTEMS DHW Heater AC-1 I Double Queen 143 LEFT NOTE TO MELD n/a Programmable Switch Programmable Switch n/a Heating & Cooling Required Heating & Cooling Required n/a n/a n/a n/a Yes Yes n/a 0.0 kW 0.0 kW n/a Constant Volume Constant Volume n/a No No n/a No No n/a Constant Tern Constant Tern n/a Constant Tern Constant Tern n/a n/a n/a n/a Air Balance Air Balance n/a Auto Auto n/a No Economizer No Economizer n/a 124 cfm 128 cfm Gas Fired Heat Pump Heat Pump 90% 8.00 HSPF 8.00 HSPF n/a Split DX Split DX n/a 11.5 SEER / 11.0 EER 11.5 SEER / 11.0 EER A O SMITH LW-750 TRANE 4TWR2018AI TRANE 4TWR2018AI Yes Yes Yes Yes Yes Yes n/a n/a Ducts in Attic 4.2 Ducts in Attic 4.2 n/a n/a Ducts in Attic 4.2 Ducts in Attic 4.2 n/a No No CODE TABLES: Enter code from table below into columns above. HEATELECTRIC HERMOSTAT?TIME CONTROL SETBACK CTRL- ISOLATION ZONES FAN CONTROL HEAT? S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes I_ VAV MINIMUM POSITION CONTROL? HEAT/ AND PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPAC Y: Ye! N: Nc O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM A. Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cerl. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH3. EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:52 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS Double Queen 118 LEFT 222 2 Bed Double Queen 247 2 Bed Queen LEFT Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 48 cfm Heat Pump 8.20 HSPF Split DX 11.5 SEER /10.4 EER TRANE TFBO4018 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NMI Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 48 cfm Heat Pump 8.20 HSPF Split DX 11.5 SEER 110.4 EER TRANE TFBO4018 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 35 cfm Heat Pump 8.20 HSPF Split DX 11.5 SEER 110.4 EER TRANE TFBO4018 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above_ NOTE TO FIELD HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air CerL M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity : Air W. Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE MOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Paae:53 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 249 ACC 2 Bed LEFT 326 2 Bed Double Queen RT 351 2 Bed Queen RIGHT TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEATICOOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Tern COOLING SUPPLY RESET Constant Temp Constant Temp Constant Tern HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN I 49 cfm 86 cfm 33 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER / 11.0 EER 11.5 SEER / 10.3 EER 11.5 SEER / 11.0 EER MAKE AND MODEL NUMBER TRANE 4TWR2018A1 TRANE 4TWR203OAl TRANE 4TWR2018A1 PIPE INSULATION REQUIRED? Yes Yes Yes PIPEIDUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic t 4.2 Ducts in Attic i4.2 VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? I SIMULTANEOUS HEAT / COOL? HIGH EFFICIENCY? PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA Y: Yes N: No NOTE TO FIELD TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Tuner O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air CerL G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 Run Initiation Time: 01/12/05 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:54 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 1 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS NOTE TO FIELD SYSTEM ME NA TIME CONTROL 353 ACC 2 Bed LEFT RTU-12 RTU-11 :jj Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kw 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEATICOOL? No No No HEATING SUPPLY RESET Constant Tern Constant Tern Constant Tern COOLING SUPPLY RESET Constant Tern Constant Tern Constant Tern HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL ECONOMIZER TYPE Auto Auto Auto No Economizer No Economizer No Economizer DESIGN O.A. CFM (MECH-3, COLUMN I) 63 cfm 545 cfm 470 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE 8.00 HSPF 8.00 HSPF 8.00 HSPF Split DX S lit DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER / 11.0 EER 10.0 SEER 19.5 EER 10.0 SEER 19.5 EER MAKE AND MODEL NUMBER TRANE 4TWR2018AI TRANE WCC048F300B' TRANE WCC048F300B' PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No I CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M• Out. Air Measure D: Demand Control N: Natural I144 A: Auto G: Gravity : Air : Water N: Not Required EC: Economizer Control See Section e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE. I EneravPro 3.1 By EneravSoft User Number: 5863 Job Number: 04088 Page:55 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME � DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME HEAT PUMP THERMOSTAT? ELECTRIC HEAT? RTU-10 -- - - - RTU-9 RTU-8 NOTE TO FIELD Programmable Switch Programmable Switch Programmable Switch Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required n/a n/a n/a Yes Yes Yes 0.0 kW 0.0 kW 0.0 kW Constant Volume Constant Volume Constant Volume No No No No No No Constant Temp Constant Temp Constant Temp Constant Temp Constant Temp Constant Temp n/a n/a n/a Air Balance Air Balance Air Balance Auto Auto Auto No Economizer No Economizer No Economizer 441 cfm 441 cfm 449 cfm Heat Pump Heat Pump Heat Pump 8.00 HSPF 8.00 HSPF 8.00 HSPF Split DX Split DX Split DX 10.0 SEER 19-4 EER 10.0 SEER 19.6 EER 10.0 SEER / 9.5 EER TRANE WCCO24F1006' TRANE WCC018F1008' TRANE WCC030F100B' Yes Yes Yes Yes Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 No No No CODE TABLES: Enter code from table below into columns above. SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPA Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 DOTES TO FIELD - For Building Department Use Only I EnergyPro 3.1 By EneravSoft User Number: 5863 Job Number: 04088 Paae:56 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE _ Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEATICOOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS RTU-7 RTU-6 I RTU-2 Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 372 cfm Heat Pump 8.00 HSPF Split DX 10.0 SEER 19.5 EER TRANE WCC042F300B• Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 465 cfm Heat Pump 8.00 HSPF Sp it DX 10.0 SEER 19.4 EER TRANE WCCO24F10013' Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 420 cfm Heat Pump 8.00 HSPF Split DX 10.0 SEER 19.6 EER TRANE WCC018F1008` Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No N-)TE TO l=1El.b CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPA Y: Yes N: No S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 1 e3 NOTES TO FIELD - For Building Department Use Only I EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:57 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME i DATE Homewood Suites Hotel 2/28/2005� YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS AC-8 AC-7 AC-6 Programmable Switch Heating & C ling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 370 cfm Heat Pump 8.40 HSPF Split DX 11.0 SEER 111.0 EER TRANE TWA060D4 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 120 cfm Heat Pump 8.00 HSPF Split DX 10.3 EER TRANE TWA090A300E* Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kw Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 168 cfm Heat Pump 8.00 HSPF Split DX 10.3 EER TRANE TWA090A300E* Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? I SIMULTANEOUS HEAT / COOL? I HEAT PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL NOTES TO FIELD - For Building Department Use Only I EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Paae:58 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS NOTE TO FIELD SYSTEM NAME AC-10 RTU-5 Exercise Room Programmable Switch Programmable Switch Programmable Switch TIME CONTROL SETBACK CONTROL Heating & Cooling Reguired Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Temp COOLING SUPPLY RESET Constant Temp Constant Temp Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN Al 3423 cfm 445 cfm 120 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.10 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 10.1 EER 9.7 SEER 19.0 EER 11.5 SEER / 11.1 EER MAKE AND MODEL NUMBER TRANE TWA120A300E' TRANE TRANE 4TWR2036AI PIPE INSULATION REQUIRED? Yes Yes Yes PIPEIDUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION I R-VALUE Ducts in Attic 4.2 Ducts in Attic 42 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No - I CODE TABLES: Enter code from table below into columns above. I HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes ELECTRIC HEAT? O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Y: Yes N: NO Sensor M: Manual Timer B: Both V: VFD O: Other C: Curve SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATIONOUTDOORDAMPERI ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. A: Auto G: Gravity Air : Water Enter Outdoor Air CFM. PIPE INSULATION REQUIRED? M: OuL Air Measure D: Demand Control N: Natural Not Required IEC:Economizer ontrol See Section Note: This shall be no less than Col. H on MECH-3. PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE. 4 e 3 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:59 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 l YSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME AC-9 Employee Break Room RTU-1 NOTE TO FIELD I TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooli R wired Heatin & Coolin R wired Heatin & Coolin Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes FI Fr T019' uGAT7 n n ten/ n n kw n n kw FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Temp COOLING SUPPLY RESET Constant Temp Constant Temp Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH3, COLUMN 1 1711 cfm 87 cfm 631 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 10.1 EER 11.5 SEER / 10.9 EER 10.5 SEER 19.5 EER MAKE AND MODEL NUMBER TRANE TWA120A300E' TRANE 4TWR2024AI TRANE PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION I R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL Y: Yes N: No PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPA S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH3. 144e3 NOTES TO FIELD - For Building Dep�ent Use Only Run Initiation Time: 01112/05 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:60 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005� YSTEM FEATURES SYSTEM NAME I MECHANICAL SYSTEMS Board Room 232 King Studio 121 Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 65 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 71 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No - Programmable Switch Heating & Coolinn Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 69 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? /COOL? HEAT PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPA Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL NOTES TO FIELD - For Building Department Use Only : 01/12/05 07:39:18 EnergyPro 3.1 By EnergySoH User Number: 5863 Job Number: 04088 Page:61 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION _ OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS 354 ACC Studio 1 353 ACC 2 Bed RIGHT 351 2 Bed Queen LEFT Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Tem n/a Air Balance Auto No Economizer 86 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Temp n/a Air Balance Auto No Economizer 80 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heatin &Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 89 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. NOTE TO FIELD HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy H: Heating C: Cooling Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch VAV MINIMUM POSITION CONTROL? Y. Yes N: No Sensor M: Manual Timer B: Both V: VFD O: Other C. Curve SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. A: Auto G: Gravity :Air : Water Enter Outdoor Air CFM. PIPE INSULATION REQUIRED? M: Out. Air Measure D: Demand Control N• Natural N: Not Required EC: Economizer Control See Section Note: This shall be no less than Col. H on MECH3. PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE. 144 e 3 EnergyPro 3.1 By EnergySoft User Number 5W3 Job Number: 04088 Page:62 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME 352 Double Queen 350 Double Queen l 348 Double Queen l (+IO[E t0 FIELD TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Tem COOLING SUPPLY RESET Constant Temp Constant Temp Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN Q 80 cfm 80 cfm 86 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.9 EER 11.5 SEER 110.9 EER 11.5 SEER 110.9 EER TRANE 4TWR2024A1 TRANE 4TWR2024A1 TRANE 4TWR2024A1 MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION I R VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? Y: Yes N: No PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPP TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:63 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE l Homewood Suites Hotel 2/28/2005 JI YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R VALUE COOLING DUCT LOCATION R VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE HEAT PUMP THERMOSTAT? ELECTRIC HEAT? SIMULTANEOUS HEAT / COOL? 346 Double Queen Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 80 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 7Ducts in Attic 4 4.2 No 344 Studio Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 65 cfm Heat Pump 8.00 HSPF S it DX 11.5 SEER / 11.0 EER TRANE 4TWR2018AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No 343 Studio NOTE TO FIELD Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 65 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Tener O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air CerL G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01112105 07:39:18 Run Code: 11055U358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:64 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME -� 342 Studio 341 Studio 340 Double Queen NOTE TOFIELD TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES Na Na n1a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Tern COOLING SUPPLY RESET Constant Temp Constant Temp Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN 1 65 cfm 65 cfm 80 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX S it DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.3 EER 11.5 SEER 110.9 EER 11.5 SEER / 10.9 EER MAKE AND MODEL NUMBER TRANE 4TWR2030AI TRANE 4TWR2024AI TRANE 4TWR2024AI PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION I R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N• Natural A: Auto G: Gravity A: Air : Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE. NOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:65 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME 11 TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? HEATING DUCT LOCATION R VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE HEAT PUMP THERMOSTAT? ELECTRIC HEAT? MECHANICAL SYSTEMS 339 Double Queen 11 338 Double Queen 11 337 Double Queen Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Tern Na Air Balance Auto No Economizer 80 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Tern n/a Air Balance Auto No Economizer 80 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 42 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required Na Yes 0.0 kW Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 80 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. SIMULTANEOUS HEAT / COOL?_ _ J HEAT AND COOL SUPPLY RESET? PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA Y: Yes N: No NOTE TO FIELD TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D• Demand Control EC: Economizer less than Col. H on N• Natural Control See Section MECH3. 144e3 Run Initiation Time: 01112i"05 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:66 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 __] YSTEMFEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 71 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.3 EER TRANE 4TWR203OAl Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Tern n/a Air Balance Auto No Economizer 71 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tem Constant Tem n/a Air Balance Auto No Economizer 71 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.3 EER TRANE 4TWR203OAl Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No I CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA Y: Yes N: No NOTE TO FIELD TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 1d4e3 VOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12105 07.39.18 Run Code: 1105544358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:67 of 126 CERTIFICATE OF COMPLIANCE Performance MECH4 PROJECT NAME ]�T �2128�12005 Homewood Suites Hotel [SYSTEM FEATURES SYSTEM NAME 333 King 332 King - 331 King NOTE TO FIELD Programmable Switch Programmable Switch Programmable Switch Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required n/a n/a n/a Yes Yes Yes 0.0 kW 0.0 kW 0.0 kW Constant Volume Constant Volume Constant Volume No No No No No No Constant emp Constant Temp Constant Temp Constant Temp Constant Temp Constant Temp n/a n/a n/a Air Balance Air Balance Air Balance Auto Auto Auto No Economizer No Economizer No Economizer 71 cfm 71 cfm 71 cfm Heat Pump Heat Pump Heat Pump 8.00 HSPF 8.00 HSPF 8.00 HSPF Split DX Split DX Split DX 11.5 SEER 110.9 EER 11.5 SEER 110.3 EER 11.5 SEER 110.9 EER TRANE 4TWR2024AI TRANE 4TWR203OAl TRANE 4TWR2024AI Yes Yes Yes Yes Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? Y: Yes N: No HEAT AND COOL SUPPLY RESET? HIGH EFFICIENCY? PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE. TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 I EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Paae:68 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH4 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 330 Studio 1 329 Studio 1 328 Studio Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.3 EER TRANE 4TWR203OAl Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.3 EER TRANE 4TWR203OAl Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No I CODE TABLES: Enter code from table below into columns above. NOTE TO FIELD HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V• VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N• Natural A: Auto G: Gravity : Air : Water N: Not Required EC: Economizer Control See Section 11"ie13 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE Run Initiation Time: 01/12/05 07:39:18 Run Code: 11055"35 EnergyPro 3.1 By EnergySoft User Number: 580 Job Number: 04088 Page:69 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME I MECHANICAL SYSTEMS 327 Studio 326 2 Bed Double Queen 11 323 Kng Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 69 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 61 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER f 11.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 73 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No I CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? SIMULTANEOUS HEAT / COOL? I HIGH EFFICIENCY? PIPE INSULATION REQUIRED?- PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPP Y: Yes N: No NOTE TO FIELD TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOORDAMPERI ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure : Not Required Note: This shall be no D• Demand Control C: Economizer 1144(e)3 less than Col. H on N• Natural ontrol See Section MECH-3. NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12/05 07:39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:70 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEMFEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS 324 King 1 321 King 322 King Programmable Switch Heating & Cooling Required n/a Yes 0.0 kw Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 79 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.3 EER TRANE 4TWR2030AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heatinq & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 83 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 111.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 98 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.3 EER TRANE 4TWR2030AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. NOTE TO FIELD I HEAT PUMP THERMOSTAT? Y: Yes N: NoVENTILATION TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B• Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V• VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N• Natural A: Auto G: Gravity : Air W: Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE NOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:71 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1' PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS NOTE TO FIELD SYSTEM NAME 300 �� RTU-3 RTU-4 Programmable Switch Programmable Switch Programmable Switch TIME CONTROL SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kw 0.0 kw 0.0 kw FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Tern Constant Tern Constant Temp COOLING SUPPLY RESET Constant Tern Constant Tern Constant Tem HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN I 109 cfm 99 cfm 99 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER / 10.3 EER 10.0 SEER / 9A EER 10.0 SEER 19.4 EER MAKE AND MODEL NUMBER TRANE 4TWR203OAl TRANE WCCO24F100B' TRANE WCCO24F100B' PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION I R VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC SIMULTANEOUS HEAT / COOL? Y: Yes N: No EAT AND COOL SUPPLY RESET? PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air lEnter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D• Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 Run Initiation Time: 01/12105 07:39;18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:72 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME � DATE Homewood Suites Hotel 2/28/2005_� YSTEM FEATURES MECHANICAL SYSTEMS NOTE TOFIELD SYSTEM NAME 303 King 302 King 305 King TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Temp COOLING SUPPLY RESET Constant Temp Constant Temp Constant Tern HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN I 83 cfm 98 cfm 71 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER / 11.0 EER 11.5 SEER 110.3 EER 11.5 SEER / 11.0 EER MAKE AND MODEL NUMBER TRANE 41WR2018A1 TRANE 4TWR203OAl TRANE 4TWR2018A1 PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION I R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? SIMULTANEOUS HEAT / COOL? Y• Yes N: No PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPA TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 I EneravPro 3.1 By EneravSoft User Number: 5863 Job Number: 04088 Paae:73 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS 1140TE TO FIELD SYSTEM NAME 3041Gng 306 Double Queen 308 Double Queen TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL ISOLATION ZONES Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required n/a n/a Na HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Tern Constant Tern Constant Tern COOLING SUPPLY RESET Constant Tern Constant Tern Constant Tern HEAT REJECTION CONTROL n/a n/a n/a ........... .. . VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN 1 79 cfm 93 cfm 93 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R-VALUE 1 COOLING DUCT LOCATION! R-VALUE VERIFIED SEALED DUCTS IN 1 CEILING/ROOF SPACE 8.00 HSPF 8.00 HSPF 8.10 HSPF Split DX Split DX Split DX 11.5 SEER 110.3 EER 11.5 SEER 110.3 EER 11.5 SEER 111.1 EER TRANE 4TWR2030A1 TRANE 4TWR203OAl TRANE 4TWR2036A1 Yes Yes Yes Yes Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? kV MINIMUM POSITION CONTRO SIMULTANEOUS HEAT / COOL? HIGH EFFICIENCY? PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto : Air Enter Outdoor Air C: Outside Air Cert. G: Gravity : Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D• Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. 144e3 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04M Page:74 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES (SYSTEM NAME TIME CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? SUPPLY RESET VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM IMECH-3, COLUMN HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R-VALUE COOLING DUCT LOCATION R VALUE Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Tern Constant Temp n/a Air Balance Auto No Economizer 71 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018AI Yes Yes Ducts in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.3 EER TRANE 4TWR2030AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N• Natural A: Auto G: Gravity : Air : Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE. NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01112/05 07:39:18 Run Code: 11055U358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:75 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-'I PROJECT NAME Homewood Suites Hotel YSTEM FEATURES DATE 2/28/2005 MECHANICAL SYSTEMS NOTE lE0 FIELD SYSTEM NAME _ 312 Studio 314 King Corner 315 IGng Programmable Switch Programmable Switch Programmable Switch TIME CONTROL SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Tern Constant Temp Constant Tern COOLING SUPPLY RESET Constant Tern Constant Tern Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN I 68 cfm 82 cfm 71 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Split DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.9 EER 11.5 SEER 110.3 EER 11.5 SEER / 10.3 EER MAKE AND MODEL NUMBER TRANE 4TWR2024AI TRANE 4TWR203OAl TRANE 4TWR2030A1 PIPE INSULATION REQUIRED? Yes Yes Yes PIPEIDUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION R VALUE Ducts in Attic 4.2 Ducts in Attic 42 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes ELECTRIC HEAT? O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Y: Yes N: NoVENTILATION Sensor M: Manual Timer B: Both V: VFD O: Other C: Curve SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPER I ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. A: Auto G: Gravity : Air : Water jEnter Outdoor Air CFM. PIPE INSULATION REQUIRED? M: Out. Air Measure D: Demand Control N: Natural N: Not Required EC: Economizer 144 er S See Section Note: This shall be no less than Col. H on MECH�. PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE EneravPro 3.1 By EnergvSoft User Number: 5863 Job Number: 04088 Page:76 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME Homewood Suites Hotel YSTEMFEATURES DATE 2/28/2005 SYSTEM NAME MECHANICAL SYSTEMS NOTE TO FIELD 316 King 317 King 318 King Programmable Switch Programmable Switch Programmable Switch TIME CONTROL SETBACK CONTROL Heating & ooling Required Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 MN FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Temp COOLING SUPPLY RESET Constant Temp Constant Temp Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN O.A. CFM MECH-3, COLUMN I 71 cfm 71 cfm 71 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX S lit DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.9 EER 11.5 SEER / 10.3 EER 11.5 SEER / 10.9 EER MAKE AND MODEL NUMBER TRANE 4TWR2024AI TRANE 4TWR2030AI TRANE 4T VR2024AI PIPE INSULATION REQUIRED? Yes Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. FAN CONTROL S: Prog. Switch H: Heating let VanesO: ELECTRIC HEAT? Y- Yes N: No Occupancy Sensor M: Manual Timer C: Cooling B: BothVFDSIMULTANEOUS =ofl: Variable PitchVAV Other C: Curve MINIMUM POSITION CONTROL? HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATIONDAMPER5Control MIZER O.A. CFMHIGH B: Air Balance Enter Outdoor AirC: EFFICIENCY? Outside Air C CFM.PIPE INSULATION REQUIRED? M put. Air Meauired D: Demand Conmizer Note: This shall be noPIPE/DUCT less than Col. H onN: INSULATION PROTECTED? Naturale Section MECH-3.SEALED DUCTS IN CEILING/ROOF SPACE Run Initiation Time: 01/12/05 07:39:18 Run Code- 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:77 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT ',DATE--- NAME Homewood Suites Hotel 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME 250 ACC Studio 249 ACC 2 Bed RIGHT 1 247 2 Bed Queen RIGHT NOT TO FIELD TIME CONTROL Programmable Switch Programmable Switch SETBACK CONTROL Heating & Cooling Required Heating & Cooling Required ISOLATION ZONES n/a n/a HEAT PUMP THERMOSTAT? Yes Yes ELECTRIC HEAT? 0.0 kw 0.0 kw FAN CONTROL Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No SIMULTANEOUS HEAT/COOL? No No HEATING SUPPLY RESET Constant Tern Constant Tern COOLING SUPPLY RESET Constant Tern Constant Temp HEAT REJECTION CONTROL n/a n/a VENTILATION Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto ECONOMIZER TYPE No Economizer No Economizer DESIGN O.A. CFM MECH-3, C0LUM!!Ij 86 cfm 94 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX S lit DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.9 EER 11.5 SEER 110.9 EER MAKE AND MODEL NUMBER TRANE 4TWR2024AI TRANE 4TWR2024AI PIPE INSULATION REQUIRED? Yes Yes PIPEIDUCT INSULATION PROTECTED? Yes Yes HEATING DUCT LOCATION I R VALUE Ducts in Attic 4.2 Ducts in Attic 2 �4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No Switch n/a Yes 0.0 kw No No Air Balance Auto No Economize 87 cfm Heat Pump 8.20 HSPF Split DX 11.5 SEER 110.4 TRANE TFB04 Yes Yes Ducts in Attic Ducts in Attic No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes ELECTRIC HEAT? Y: Yes N: NoVENTILATION O: Occupancy Sensor M: Manual Timer C: Cooling B: Both Isolation Zones. P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPERrN:Not ONOMIZER O.A. CFM B: Air Balance A: Auto Enter Outdoor Air HIGH EFFICIENCY? C: Outside Air Cert. G: Gravity ter CFM. PIPE INSULATION REQUIRED? M: Out. Air Measure D: Demand Controlconomizer N• Natural Required Control See Section 144 e 3 Note: This shall be no less than Col. H on MECH-3. PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE. EnercivPro 3.1 By EneryySoft User Number: 5863 Job Number: 04088 Page:78 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET ICOOLING SUPPLY RESET VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R VALUE COOLING DUCT LOCATION R-VALUE 248 Double Queen 246 Double Queen 244 Double Queen Programmable Switch Programmable Switch Programmable Switch Heating & Cooling Required Heating & Cooling Required Heating & Coolinq Required n/a n/a n/a Yes Yes Yes 0.0kW 0.0kW 0.0kW Constant Volume Constant Volume Constant Volume No No No No No No Constant Tem Constant Tern Constant Tern Constant Tern Constant Tern Constant Tern n/a n/a n/a Air Balance Air Balance Air Balance Auto Auto Auto No Economizer No Economizer No Economizer _ 80 cfm 80 cfm 86 cfm Heat Pump Heat Pum Heat Pump 8.00 HSPF 8.00 HSPF 8.00 HSPF S In DX Split DX Split DX 11.5 SEER 110.9 EER 11.5 SEER / 10.9 EER 11.5 SEER 110.9 EER TRANE 4TWR2024A1 TRANE 4TWR2024A1 TRANS 4TWR2024A1 Yes Yes Yes Yes Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 1 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 I No I I No I I No 111 11 HEAT PUMP THERMOSTAT? vT TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes ELECTRIC HEAT? No O: Occupancy M: Manual Timer C: Cooling B: Both Isolation Zones. P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROLSensor . OLSIMULTANEOUS HEAT / CON: HEAT AND COOL SUPPLY RESET? TION OUTDOOR DAMPER t ECONOMIZER O.A. CFM ce Auto A: Air Enter Outdoor Air HIGH EFFICIENCY? ir Cert. easure rDemand G: Gravity W: Water N: Not Required EC: Economizer CFM. Note: This shall be no less than Col. H on PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? Control Control See Section 144 e 3 MECH-3. SEALED DUCTS IN CEILING/ROOF SPACE. Run Inrttation time: U7/lz1u* u1 :sv: io rculi . wvv-. ....... EneravPro 3.1 By EnerpySoft User Number: 5863 Job Number: 04088 Page:79 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 (PROJECT NAME - - -- - DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 242 Double Queen 11 240 Studio 1 239 Studio Programmable Switch Programmable SwuTdn Heating & Coorm Required & Cooft R Na Na Yes Yes 0.0 kW 0.0 kW Constant Vokume Canstm t Volume No No No No Cow Temp Constant Temp Constant Temp Consfiart Temp n/a n/a Air Bice Air Balance Auto Auto No Economizer No Economizer 80 cfm 65 cfm Heat Pump Heat Purnp 8.00 HSPF 8.W HSPF Sprit DX DX 11.5 SEER 111.0 EER 11.5 SEER 111.0 EER TRANE 4TWR2018A1 TRANE 47WR201SAI Yes Yes Yes Yes Duds in Attic 42 Duets in Attic 42 Ducts in Attic 4.2 Duds in Attic 4.2 No No Pragrammable Switch Heatim & Cooing Required n/a Yes 0.0 kW Constant Vokunne No No ConslaritTerm Constant Temp n/a Arc Balance Auto No Economim 65 cum Heat Pump 8.00 HSPF SpIft DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4-2 Duds in Attic 4.2 No F CODE TABLES: Enter code bean table below aft columns above. HEAT PUMP THERMOSTAT? 71ME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch W Heating Ender Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor $: Both V: VFD SIMULTANEOUS HEAT / COOL? . e M: Manual Timer O: Other C: Curve HEAT AND COOL SUPPLY RESET? I VENTILATION JOUTDOORDAMPER1 ECONOMIZER I OA CFM PIPE INSULATION REQUIRED? C: Outside Air Cent. G: Gravity : Water FM. M: OuL Air Measure N: Not Required Note: This shall be PIPEIDUCT INSULATION PROTECTED? D. Demand Control :Economizer less than Col. H on SEALED DUCTS IN CEIUNGNWM SP N. Natural 4u1. of See Section IV 3. I EnemvPro 3.1 By EnemvSoft User Number. 580 Job Number 04088 Peae:80 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood_ Suites Hotel _ 2/28/2005 YSTEM FEATURES SYSTEM NAME L- 237 Studio 238 Studio P minable Swdch Programmable Swdch Heafm & Coofum Required Heatina & bw Recluired n/a rVa Yes Yes 0.0 kW 0.0 kV1f Constant Wurrie Constant Volume No No No No Constant Term Constard Temp Constant Ternp Cent Ternp n/a n/a Air Balance Air Balance Auto Auto No Econonftw No Econombw 65 cfhn 65 chn Heat Heat Purnp 8.0D HSPF 8.00 HSPF Split DX Split DX 11.5 SEER 110.9 EER 11.5 SEER / 11.0 EER TRANE 4TWR2024AI TRANE 4TWR2018AI Yes Yes Yes Yes Ducts in Attic 42 Duds in Aft 4.2 Duds in Attic 4.2 Duds in Attic 4.2 No No 1 236 Double QUM CODE TABLES: Enter code Hoorn table below into cohrams above: HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P. Variable Pitch VAV MINIMUM POSITIONXX)NTROL? Sensor B: Both V. VFD SIMULTANEOUS HEAT I COOL? Y: Yes M: Manual Turner O: Other C: Curve N: No HEAT AND COOL SUPPLY_ SET?I VENTILATION - � BtJTBOOR DAMPERI ECONOMIZER I OA CFM PIPE INSULATION REt0U1RED? C: Outside Air Cert. G: Gravity LNot er CFM. M: Out. Air Measure Required Note: This shall be no PIPEMUCT INSULATION PROTECTED? D: Demand Control nomizer lessthan Col. H on ..� _, .......,.�„ ... - ..---- N: Natural See Section MECH3. 3.1 Sy Enm yW User Number: 5863 Job Number: 04M Page:81 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/200 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEATICOOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN OJL CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFIMNCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R-VALUE COOLING DUCT LOCATION R VALUE VERIFIED SEALED DUCTS IN CEdJNGIROOF SPACE MECHANICAL SYSTEMS M5 Double Queen 2M Double Queen I I 2M Double Queen Pr�ble Switch -Heat'& Cooling Required -Heatim nda Yes 0.0 kW Constant Vdume No No Constant Temp Constant Taw n/a Air Balance Auto No Econonf¢er 80 Cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Duds in Attic 42 No PfOrdmmable Switch HeadHeafingq & Coofina RecOred n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Batance Auto No Economizer 80 cffn Heat Pump 8.00 HSPF Sprit DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Duds in Attic 4.2 Duds in Attic 42 No Pw9rammable Switch Heating & Coolingg Required n/a Yes 0.0 kW Constant Volume No No Constant Temp ConstantTemp n/a Air Balance Auto No Economizer 80 cfrn Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 42 Duds in Attic 4.2 No C CODE TABLES: Enter code from table below into cohnnam above. HEAT PUMP THERMOSTAT? Y• Yes 11ME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Tuner H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEAT AND COOL SUPPLY RESET? N: No -- VENTILATION OUTDOOR DAMPERL NOMIZER OJL CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity er Required nomizer See Section Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE NOTES TO FIELD - For Building Department Use Only 3.1 By EneWSon User Number: 5863 Job Number: 04088 Page:82 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 1__ 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 231 IGng 227 lQng I 229 Kng Programmable Switch Heating & Coohm Required n/a Yes 0.0 kw Constant Volume No No Constant Temp Constant Temp rda Air Balance Auto No Economizer 71 cfrn Heat Pump 8.00 HSPF Spit DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Pro Irarnmable Switch Heating & Cooling Required n/a Yes 0.0 MN Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 71 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No CODE TABLES: Enter code Lram table below into cokma above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT ICOOL? Y: Yes M: Manual Timer O: Other C: Curve HEAT AND COOL SUPPLY RESET? N. r VENTILATION I OUTDOOR DAMPER I ECONOMY O.A. CFM PIPE INSULATION REQUIRED? C: Outside Air Cent G: Gravity . Water FM. M: Out Air Measure N: Not Required Note: This shall be no PIPEIDUCT INSULATION PROTECTED? D: Demand Control EC: Economizer less than Col. H on N: Natural of See Section MECH-3. SEALED DUCTS IN CEILINGIROOF SPACE _ 1. 4_4te)3 NOTES TO FIELD - For Building Department Use Only 3.1 By EnergySofl User Number. 5863 Job Number. 04088 Page:83 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME Homewood Suites Hotel I UATE 2/28/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEATICOOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN OA CFM MECH3, COLUMN HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION fM=RED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R-VALUE COOLING DUCT LOCATION Ra/ALUE VERIFIED SEALED DUCTS IN CEIIJNGIROOF SPACE Pm9rammable Switch Heating & Coohna Rewred n/a Yes 0.0 kW Constant Vdk me No No Constant inp Constard Ternp n/a Air Balance Auto No Econontw 71 cfm Heat Pump 8.00 HSPF Spit DX 11.5 SEER / 10.9 EER TRANE 4TWR2024AI Yes Yes Duds in Attic 42 Ducts in Attic 4.2 No Pro mmmable Switch Heati & Cooling Required We Yes 0.0 kW Constant Volume No No Constant Temp Constant TaW n/a Air Balance Auto No Ec onom¢er 71 cfm Heat Pump 8A0 HSPF DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4.2 Ducts in Attic 4.2 No Pro mmmable Switch Heating & CooGmg Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp Na Air Balance Auto No Econom¢er 88 cfm Heat Ptun 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024AI Yes Yes Duds in Attic 42 Duds in Attic 4.2 No CODE TABLES: Enter code from table below into cokonrs above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRI- ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Nunber of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT / COOL? Y: Yes I M: Manual Timer O: Other C: Curve HEAT AND COOL SUPPLY RESET? N. VENTILATION OUTDOOR DAMPER ECONOMIZER OA CFM- --I HIGH EFFICIENCY? B: AN Balance A: Auto LN.--Not Enter Outdoor Air PIPE INSULATION REMMED? C: Outside Air CerL G- Gravity er CFM. M: OuL Air Measure Required Note: This shall be no PIPERMT INSULATION PROTECTED? D: Demand Control nornizer less than Col. H on __-- -- _-.--- --• _-• ---_-_-- _---- N: Natural See Section MECH-3. 3.1 By Er"gySoit User Number: 5863 Job Number 04088 Page:84 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME - DATE Homewood Suites Hotel 2/28/2005 1 [SYSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME 226 Studio 223 Studio 224 Studio NOTE TO FIELD Pmgrdmmable Switch Pmgwnmabie Switch Pro minable Switch TIME CONTROL SETBACK CONTROL Heatim & Coolina ReqL&W Heaft 8 Coam Rewred Hen & Coofi Required ISOLATION ZONES rya Na rya HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 IcW FAN CONTROL Constant Vokrme Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEATICOOL? No No No HEATING SUPPLY RESET Constant I@W Constant Temp CWstard Twy COOLING SUPPLY RESET Constant Tefflp Constant Temp ConsWTenip HEAT REJECTION CONTROL rya nla nia VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economimer No Economizer No Econom¢er DESIGN OJL CFM MECH-1, COLUMN I 68 cfrn 69 cfm 68 chn HEATING EQUIPMENT TYPE Heat Punw Heat Purnp Heat Purnp HEATING EQUIPMENT EFFICIENCY 8.0D HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Split DX Spift DX Spit DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.9 EER 11.5 SEER 111.0 EER 11.5 SEER 110.9 EER MAKE AND MODEL NUMBER TRANE 4TWR2D240k1 TRANE 4TWR2018Ai TRANE 4TWR2024AI PIPE INSULATION REQUIRED? Yes Yes Yes PIPEIDUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION R NALUE Ducts in Attic 42 Ducts in Attic 4.2 Duds in At is 4.2 COOLING DUCT LOCATION R VAi UE Ducts In Attic 4.2 Duds in Attic 42 Duds in Attic 4.2 VERIFIEDIN EO �D SEALED SPACE No No No No CODE TABLES: Enter code fh= table below into colums above. I EnerwPro 3.1 By EnefuvSoft User Number: 58M Job Number: "M Page:85 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME 164TE2/28/2005Homewood Suites Hotel 1 [SYSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 222 2 Bed Double Queen RT 1 219 lOng I 220 mw TIME CONTROL Programmable Swllch Pro mmable Swftch Programmable Switch SETBACK CONTROL & Coolft Required Heatim & Cooling Reguired "@@ft & Cooligg Required ISOLATION ZONES n/a nla n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 kW 0.0 kW 0.0 kW FAN CONTROL C nstant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEATICOOL? No No No HEATING SUPPLY RESET Constwt Temp Constant Temp Constant Igmp COOLING SUPPLY RESET Constant Tamp Constard Tamp Constant Temp HEAT REJECTION CONTROL n/a n/a n/a VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Arlo Auto ECONOMIZER TYPE No Ecorxwdm No Economizer No Econombw DESIGN OA CFM MECH3, COLUMN 1 98 cfm 73 cfm 79 cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 8.2D HSPF 8.00 HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Sprd DX Sprit DX Spit DX COOLING EQUIPMENT EFRCIENCY 11.5 SEER / 10.4 EER 11.5 SEER 111.0 EER 11.5 SEER 110.3 EER MAKE AND MODEL NUMBER TRANE TFBO4018 TRANE 4TwR2018A1 TRANE 4TWR2030Al PIPE INSULATION REQUIRED? Yes Yes Yes PIPEIDUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION Ra/ALUIE Duds in Attic 42 Duds in Attic 4.2 Duds in Attic 4.2 COOLING DUCT LOCATION R-VALUE Duds in Attic 4.2 Duds in Attic 42 Duds In Attic 4.2 VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE No No No CODE TABLES: Enter code from table below ado cokams above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of t: Intel Vanes O: Occupancy C: Cooling isolation Zones. P: Variable Pitch VAV MINIMUM POSITM CONTROL? Sensor B. Both V: VFD SIMULTANEOUS HEAT / COOL? Y: Yes M: Manual Tuner O: Other C: Curve -- HEAT AND COOL SUPPLY RESET? N: No VENTILATION o—um OR DAMPER ECONOIMIZER OA. CFM PIPE INSULATION REQUIRED? C: Outside Air Cert. G: Gravity : Water FM. M: Out. Air Measure N: Not Required Note: This shall be no PIPE/DUCT INSULATION PROTECTED? D. Demand Control EC, Economizer less than Col. H on N: Natural ControlSee Section MECH3. SEALED DUCTS IN CEILINGIROOF SPACE 144/e13 I EnetmPro 3.1 By EnergvSoR User Number: 5863 Job Number. 04088 Page:86 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES ucruemrw1 cvcitu¢ SYSTEM NAME Switch Heating & Cooling Required n/a Yes 0.0 kW Canstard Volume No No Constant T Constant Tamp n/a Air BaLwm Auto No Econombw 83 cfm Heat Pum 8.0D HSPF Spit DX 11.5 SEER III . 0 EER TRANE 4TWR2018AI Yes Yes Duds in Attic 4.2 -t Duds in Attic 4.2 No PmWwmuble Switch Hgaft & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Twy Na Air Balance Auto No EconwiKmer 71 ctm Heat Pump &W HSPF Split DX 11.5 SEER 111.0 EER TRANE 4TWR2018AI Yes Yes Duds in Atticc 4.2 Ducts inAllic A No CODE TABLES: Enter code from table below into coltanns above. HEAT PUMP THERMOSTAT? Y: Yes TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Toner H: Healing C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P. Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? N. No VENTILATION I OUTDOOR DAMPER I ECONOMIZER OA CFM PIPEJDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILJNGNWOF SPA C: Outside Air Cert G: Gravity : Water FM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH3. I EneravPro 3A By EneravSoft Usm Number: 5863 Job Number. "M Page:87 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 IPROJECT NAME DATE — Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS �,s5lv 200 King 11 202 KEng Programmable Switch H 8 C4ofina Required n/a Yes 0.0 kW Constant Vokxne No No Constant Temp Constant Ternp n/a Air Balance Auto No Economizer 83 dm Heat Pump &W HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heating & Coofing Reqtired n/a Yes 0.0 kW Constant Volume No No Castant Temp Constant T n/a Air Balance Auto No Economizer 98 cfm Heat Pump 8.00 HSPF SDX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heating & Cooling Required n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 79 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.3 EER TRANE 4TWR203OAl Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No CODE TABLES: Enter code from table below ifo cokmn above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL XTANEOUS HEAT I COOL? Y• Yes AND COOL SUPPLY RESET? N: No PRE INSULATION REQl1RED7 PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPIT S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOM¢ER OA CFM B: Air Balance A: Auto • Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W. Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D; Demand Cool : Economizer less than Col. H on N: Natural lControl See Section MECH-3. e NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 01/12/05 07.39:18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number 04088 Page:88 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME --- — -- ----- --- DATE � Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 204 Double Queen I I 2W ACC-DQ 207 Studio Pr Switch Pro ramble Swtch Heatim & Coorkm Required H & Coplim Reguired n/a rda Yes Yes 0.0 kW 0.0 kW Constant Volume Constant Volume No No No No Comet Team Constant Temp Constant Temp Constant Temp n/a Na Air Balance Air Balance Auto Auto No Economiser No Ecawmtaer 93 cfm 94 cfrn Heat PupV Heat Pump 8.00 HSPF 8.OQ HSPF Spit DX Split DX 11.5 SEER / 10.3 EER 11.5 SEER 110.3 EER TRANE 4TWR2030A1 TRANE 4TWR2030A1 Yes Yes Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 Duds in Attic 4.2 Duds in Attic 4.2 No No Pro mmmabie Switch Heating & Coolingg Required n/a Yes 0.0 lW Constant Volume No No Constard Temp Constant Temp n/a Air Balance Auto No Economizer 71 cfm Heat Purn 8.00 HSPF Spit DX 11.5 SEER 111.0 EER TRANE 4TWR2018A1 Yes Yes Duds in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Eller code from tabte below iota cokmwm above. I EnemyPw 3.1 By EnewSoft User Number: 5863 Job Number: 04(= fte:89 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME �212812005 Homewood Suites Hotel j YSTEM FEATURES SYSTEM NAME PmgiWnffiaki1eSWfth Progranirnable Switch Heatim & Cooling Required Healing & Cool' R red Na n/a Yes Yes 0.0 kW 0.0 kW Constant Volume Constant Volume No No No No Constant Temp Constant Temp Constant Ternp Constant Teffip n/a n/a Air Balance Air Balance Auto Auto No Econonner No Economizer 68 cfin 68 cftn Heat Pump Heat PLyrip 8.00 HSPF 8.00 HSPF Spit DX Vft DX 11.5 SEER 110.9 EER 11.5 SEER / 10.9 EER TRANE 4TWR2024AI TRANE 4TWR2024AI Yes Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 Duds In Attic 4.2Ducts in Attic 4.2 No No Programmable Switch Heatinp & Goofing Required n/a Yes 0.0 kW Constant Volume No No Com tact jeM Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Purnp 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No NOTE To FIELD CODE TABLES: Eider code frost table below into columns above. HEAT PUMP THERMOSTAT? ELECTRIC HEAT? MINIMUM f: Yes N: No PWEIDUCT INSULATION PROTECTED? TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL S: Prog. Switch H: Heating Eider Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER1 ECONOMIZER OA CFM B: Air Balance A: Auto Air Eider Outdoor Air C: Outside Air Cert_ G: Gravity . Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control C: Economizer less than Col. H on N: Natural of See Section MECH3. 1 e MID 0,11-711517111 3.1 Df EnewSoft User Number. 5863 Job Number 04088 Page:90 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 `f, ►T1l a DATE Homewood Suites Hotel I 2/28/2005 1 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 212 KW Comer 11 213 fQng 214 Mng Pmgranmable Switch Pmgrammable Switch Heatim & Coolkm Required. Hednq & Coofing Required. n/a nla Yes Yes 0.0 kW 0.0 kW Constant Vdume Constant Volume No No No No Constant Terry Constant Temp Constant Tenip Constant Temp n/a n/a Air balance Air Balance Auto Auto No Economizer No Ecorwmmer 82 dm 71 cfm Heat Punip Heat Pump 8.00 HSPF 8.00 HSPF Spfit DX SpW DX 11.5 SEER 110.3 EER 11.5 SEER 110.3 EER TRANE 4TWR2030A1 TRANE 4TWR203GAI Yes Yes Yes Yes Ducts in Attic 4.2 Duds in Attic 4.2 Duds in Attic 42 Duds in Attic 4.2 No No Pro rammable Switch Heafirm & Coofing Reauked Na Yes 0.0 k N Constant Vok ne No No Constant Temp Constant Temp n/a Air Balance Auto No Econonfoer 71 cfm Heat P 8.00 HSPF $pit DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No CODE TABLES: Enter code Inman table below into coluam above. HEAT PUMP THERMOSTAT? .- Yes TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Turner H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? VENTEATION OUTDOOR DAMPER ECONOMIZER OA CFM HIGH E#FICIENCY? B: Air Balance C: Outside Air CerL M: OuL Az Measure D: Demand Control N: Natural A: Auto G: Gravity • Air : Water N: Not Required EC: Economizes Control 1 e See Section Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQURED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGAROOF SPACE 3.1 Energy" User Number. 5863 Job Number 04088 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME 7]��2�12812005 Homewood Suites Hotel YSTEM FEATURES YSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEATICOOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN OJL CFM MECHJ, COLUMN HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? HEATING DUCT LOCATION R VALUE COOLING DUCT LOCATION RaIALUE VER�IEO SEALED DUCTS IN CEMJNGIR" SPACE MECHANICAL SYSTEMS 216 Kog 215 IGng I IQng 114 Pragrarrunable Switch Heatffw 8 Cookm Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Teinp Na Air Balance Auto No Econo"Aw 71 cim Heat Pump &W HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 42 Ducts in Attic 4.2 No Pm7mmable Switch Heaft & Coofina Required Na Yes 0.0 kW Constant Vahrne No No Constant Temp Constant Temp m1a Air Balance Auto No Eoonorrzer 71 cfm Heat Purnp 8.00 HSPF Spit DX 11.5 SEER 110.3 EER TRANE 4TWR2030AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heatina & Coolim Required, Na Yes 0.0 kW Constant Volume No No Constant Tem Constant Temp n1a Air Balance Auto No Eoonom¢er 72 c lin Heat Ptun 8.00 HSPF Spit DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 4.2 Ducts.ai Attic 4.2 No CODE TAMMS: Enter cone from fable below into cohnnns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAL? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT I COOL? N: No M: Manual Tuner O: Other C: Curve HEAT AND COOL SUPPLY RESET? VENTILATION I OUTDOOR DAMPER F ECONOMIZER O.A. CFM PIPE INSULATION REQUIRED? C: Outside Air Cert. G: Gravity . Water CFM. M: Out Air Measure N: Not Required Note: This shall be no PIPEJDUCT INSULATION PROTECTED? D: Demand Control EC: Economizer less than Col. H on N: Natural See Section MECH-3. SEALED DUCTS IN CEILINGIROOF SPACJ 1144(ep NOTES TO FIELD - For Building Depgrtment Use OnlyI I EneraWro 3.1 By Enera4cft User Number: 58M Job Number. "M Paae:92 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel _ 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS (SYSTEM NAME IGng 112 King 113 my 111 TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV.MINIMUM POSITION CONTROL? SIMULTANEOUS HEATICOOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN OJL CFM ECH3, COLUMN HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R,VALUE COOLING DUCT LOCATION RaVALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE Pmgrammble Switch Healing & Cooft Recluired n/a Yes 0.0 kW Constant Volume No No Constant Temp Cow Temp n/a Air Balance Auto No Economizer 72 chn Heat Pump 8.00 HSPF Spit DX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Aftic 4.2 Duds in Attic 4.2 No Pro mavroble Swftch Heati & Cooling Required n/a Yes 0.0 kW Cow Volume No No Constant Ternp Constant T n/a Air Balance Auto No Economizer 72 chn Heat Purnp 8.00 HSPF Split DX 115 SEER 110.3 EER TRANE 4TWR2030AI Yes Yes Duds in Attic 4.2 Duds In Attic 4.2 No ProWammable Switch Heatlng & CookRequked n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 72 ckn Heat Pump 8.00 HSPF Spit DX 11.5 SEER 110.3 EER TRANS 4TWR203OAl Yes Yes Duds in Attic 4.2 [kids in Attic 42 No CODE TABLES: Enter code from table below auto coksms above. HEAT PUMP THERMOSTAT? I TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL SIMUL RESET? PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CL7UNGIROOF SPA Y• Ye N: Nc S: Prog. Switch H: baling Etter Number of I: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P. Variable Pitch Sensor B: Both V: VFD M: Manual Timer O: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER OJL CFM B: Air Balance A: Auto A, Air Enter Outdoor Air C: Outside Air Cert. G: Gravity Vk Water CFM. M: Out, Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer ss than Col. H on N: Natural of See Section MECH3. Run Initiation Time: 0111V05 07:39:18 Run Code: 11OSS44358 EnergyPro 3.1 By EnergySalt User Number. SM Job Number: "M Pege:93 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS Fling Comer 30 11 Studio 107 11 Studio 108 Programmable Switch Heaffina 8 Cooling Required. Na Yes 0.0 kW Constant Vokune No No Constant Temp Constant Ternp Na Air Balance Auto No Econon*w 83 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER / 10.3 EER TRANE 4TWR203GAI Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No Prorammalft Switch Head & Coofinq Reggred n/a Yes 0.0 kW Constant Volume No No Canard Temp Constant Tamp nla Air Balance Auto No Econommer 68 chn Heat PUFM 8.00 HSPF Spit DX 11.5 SEER /10.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 42 Duds in Attic 4.2 No Programmable Switch Heating & Coofirw Reguired Na Yes 0.0 kW Constant Volume No No Constant Ternp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pum &W HSPF Spit DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 42 Duds in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? Y: a TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Swddr O: Occupancy Sens M: Manual Timer H: Healing C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER OA CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A, Air : Water : Not Required C: Economizer See Sedion e3 Enter Outdoor Air FM. Note: This shall be no than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CE0.INGAWM SPACE I EnerawP►o 3.1 Br EneravSoft User Number: 5863 Job Number 04088 Page:94 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME - - — DATE — ---- -� Homewood Suites Hotel 2/28/2005 YSTEM FEA URES SYSTEM NAME MECHANICAL SYSTEMS Studio 108 11 ACC Double 104 ACC Double 102 Programmable Switch Heafina & Cooling RequinW Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Tenip Ala Air Balance Auto No Econom¢er 68 cfm Heat Pump 8.00 HSPF Spit DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heating & CwWw Required Na Yes 0.0 kW Constant Volume No No Constant Temp Constant Ternp n!a Air Balance Auto No Economizw 90 cfm Heat PurM 8.00 HSPF S DX 1 t.5 SEER 110.3 EER TRANE 4TWR2030A1 Yes Yes Duds in Attic 42 Duds in Attic 4.2 No CODE TABLES: Ender code from table below kft columns above. HEAT PUMP THERMOSTAT? Y: Yes TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Tuner H: Healing C: Cooling lk, Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT ICOOL? HEAT AND COOL SUPPLY RESET? N. IVVENTILA� OUTDOOR DAMPER I ECONOMIZER OA CFM Outside Air Cert. G: Gravity : Water CFM. PIPE INSULATION REQUIRED? M: M: Out. Air Measure D: Demand Control N: Natural N: Not Required EC: Economizer See Section Note: This shall be no less than Col. H on MECH3. PIPE/DUCT INSULATION PROTECTED? AC DF SEALED DUCTS IN CEILINGIROSPE 1AA101a K n InMR1110n I11m: U1f7uu9 uf:jV:7S KUn (:Oae:-twou4435ii EnergyPro 3.1 'By EnetgySofl User Number. 5863 Job Number: "M Page:95 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME -- -- -- - - -- - - -- DATE - Homewood Suites Hotel 2/28/2005 ISYSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS long 100 1 L Fong 116 1 Double Queen 118 RIGHT Programmable Switch Programmable Switch Heatffw. & Coohryq Requked Heating & Coofigg Required Na Na Yes Yes 0.0 kW 0.0 kW Constant Volume Constant Volume No No No No Constant Temp Constant Temp Constant Temp Constant Temp nla n/a Air Balance Air Balance Auto Auto No Economizer No Economizer 79 dnr 79 cfm Heat Pump Heat Pump 8.00 HSPF 8.00 HSPF Split DX Spit DX 11.5 SEER 110.3 EER 11.5 SEER 110.3 EER TRANE 4TWR2030AI TRANE 4TWR203GAI Yes Yes Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 Duds in Attic 4.2 Duds in Attic 4.2 No No ProgrammaNe Switch Heating & 999ft Required rUa Yes 0.0 kW Constant Volume No No Count Temp Constant Temp, n/a Air Balance Auto No Economizer 114 cfm Heat Pump 8.20 HSPF Split DX 11.5 SEER f 10.4 EER TRANS TFBO4018 Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No CODE TABLES: Enter code frorn table below into colours above_ HEAT PUMP THERMOSTAT? : No TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Swwch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C_Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER OA CFM —I PIPE INSULATION REQU ED? C: Outside Air Cert. G: Gravity . Water FM. M: OuL Air Measure N: Not Required Note: This shall be no PIPEIDUCT INSULATION PROTECTED? D. Demand Control EC: Econondzer less than Col. H on N: Natural See Section ECH-3. SEALED DUCTS IN CEILINGIROOF SPACE e 3 3.1 By EnergySofl User Number 5863 Job Number: 04068 Page:96 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN OA CFM MECH3, COLUMN 1 HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPEMMT INSULATION PROTECTED? HEATING DUCT LOCATION R VALUE COOLING DUCT LOCATION R VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS King 115 Studio 123 1 Studio 120 Progrwnmabie Sm" HeatiLig & Cooljqg Recriked nn/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp n/a Air Salanoe Auto No Economizer 71 cfm Heat Pwn 8.00 HSPF Spht 11.5 SEER / 11.0 EER TRANE 4TWR2018AI Yes Yes Duds in Attic 4.2 Duds in Attic 42 No Programmable Switch Hea6 & Goofing Required Na Yes 0.0 kw Constant Vokune No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF SpIk DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heating & Cooling R wired n/a Yes 0.0 kW Constant Volume No No Constant Temp Constant Temp Na Air Balance Auto No Economizer 68 cfm Heat Pump 8.00 HSPF Spfit DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Dutfs in Attic 4.2 Duds in Attic 4.2 No L CODE TABLES: Enter code from table below into cokams above. HEAT PUMP THERMOSTAT? Y: Yes N: No 11 TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Tuner H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VA MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT 1 COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER OA CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out Air Measure D: Demand Control N: Natural A: Auto G: Gravity : Air W. Water N: Not Required EC: Economizer trot See Section e Enter Outdoor Air FM. Note: This shall be no less than Col. H on MECH 3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE MOTES TO FIELD - For Building Department Use Only EnergyPro 3.1 By EnergySoft User Number 58M Job Number: 04088 Page:97 of 126 1 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel _ 2/28/2005 WY -STEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS Stufio 122 IGng 125 1 IQV 127 Programmable Switch Heatim & Cwrfftq Recgired We Yes OA kW Constant Vdume No No Corstar>t TgMP Constant Temp Na Air Balance Auto No Economizer 72 cftn Heat Ptffnp 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024A1 Yes Yes Duds in Attic 42 Duds in Attic 4.2 No Programmable Switch Heaft & ing Required n/a Yes 0.0 kW Constant Volume No No Corrsfarrt Temp Constut Temp n/a Air Balance Auto No Economizer 72 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024A1 Yes Yes Ducts in Attic 4.2 Duds in Attic 4.2 No CODE TABLES: Enter code from table below aft cow above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes O: Occupancy C: Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V: VFD SIMULTANEOUS HEAT / COOL? Y: Yes M: Manual Timer O Other C: Curve N: No — HEAT AND COOL SUPPLY RESET? I VENTSAVION I OUTDOOR DAMPERI ECONOMIZER I O.A. CFM PIPE INSULATION REQUIRED? Q Outside AN Cerl. G: Gravity . Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no PIPEIDUCT INSULATION PROTECTED? D. Demand Control C: Economizer less than Col. H on ........�.............—.— N: Natural Control See Section MECH3. Run initiation Time: 0112105 07:39:18 Run Code: 1105SWSS EnergyPro 3.1 By Energy" User Number. 8863 Job Number: 04088 Page:98 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME rDATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS Kng 129 King 124 11 tong 126 ProWanmable Switch Heatim & Coahm R n/a Yes 0.0 kW CortstmA Vokam No No Constant Temp Constant Temp n/a Air Balance Auto No Econo n w 72 cfm Heat PLffnp 8.0D HSPF Spit DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 42 Ducts in Attic 4.2 No Proqwmmble Switch Heating & Goolpa Required nia Yes 0.0 kW Constwt Vow No No Constant Tamp Constant Teffy n/a Air Balance Auto No Ecorayk er 72 cfm Heat PufW 8.00 HSPF Spit DX 11.5 SEER / 10.9 EER TRANE 47WR2024A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 CODE TABLES: Er*w code *am table below info colums above. EnergyPro 3.1 By EnergyW User Number. 580 Job Number: 04088 Page:99 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS 1G, I Double Queen 133 11 Double Queen 131 TIME CONTROL Programmable Switch Programmable Switch Programffiable Switch .... . .... SETBACK CONTROL HeWm & Coolina Required Heatim & Cooling Required Heatina & CooHng Regaired ISOLATION ZONES Na Na Na HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0 MN 0.0 kw 0.0 kW FAN CONTROL Constant Volume Constant Volume Constant Voume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEATICOOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Temp COOLING SUPPLY RESET Constant Tom Constant Temp Constant Temp HEAT REJECTION CONTROL Na Na Na VENTILATION Air Batanoe Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Econom¢er No Econom¢er No Economizer DESIGN OA CFM MECH-3, COLUMN 72 cfm 79 ctm 79 C(m HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pam HEATING EQUIPMENT EFFICIENCY 8.OD HSPF 8.OD HSPF 8.00 HSPF COOLING EQUIPMENT TYPE Spht DX Sprd DX Split DX COOLING EQUIPMENT EFFICIENCY 11.5 SEER 110.9 EER 11.5 SEER 110.9 EER 11.5 SEER 110.9 EER MAKE AND MODEL NUMBER TRANE 4TWR2024AI TRANE 4TWR2024A7 TRANE 4TWR2024A1 PIPE INSULATION REQUIRED? Yes Yes Yes PNTJDUCT INSULATION PROTECTED? Yes Yes Yes HEATING DUCT LOCATION R-VALUE Duds in Attic 42 Duds in Attic 4.2 Duds in Attic 4.2 COOLING DUCT LOCATION R NALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Duds in Attic 4.2 VERIFIED SEALED DUCTS IN CEILINGIROOF SPACE No No No CODE TABLES: Enter code firma fable below into coManns above. 3.1 by EnergySoft User Number: 5863 Job Number: 04088 Page:100 of 126 :ERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME — — DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME Double Queen 130 Double Queen 132 Studio 137 18 Programmable Swthch Heating & Cooling Rewired n/a Yes 0.0 kw Constant Vokune No No Constant Temp Constant Taw n/a Air Balance Auto No Econorber 79 ctm Heat Puny 8.00 HSPF Spit DX 11.5 SEER 111.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below Into cokmm above. HEAT PUMP THERMOSTAT? Y• Yes N: No TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT I COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER OA CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert_ M: Out. Air Measure D: Demand Control N: Natural — - --- A: Auto G: Gravity -- : Air : Water N: Not Required EC: Economizer Control See Section 144He)3 ___ Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECHJ. PIPE INSULATION REQUIRED PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILINGIROOF SPACE J 3.1 By EneUrooft User Nuxn6w.. 590 Job Number. 04088 Page:101 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 1 2//28/20055 YSTEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS Studio 135 L Studio 134 1 Studio 136 Programmable Switch Heatim & Coiftgq R Na Yes 0.0 kw constant volume No No Constant Tem Constant Temp n/a Air Balance Auto No Ecorronrier 65 cfrn Heat Punip 8.00 HSPF Split DX 11.5 SEER / 10.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Prpgrammable Switch Heaft & Goofing R ired Na Yes 0.0 kW Constant Vokrme No No Constant Temp Constant Temp rr/a Air Balance Auto No Economizer 65 cfm Heat Ptirrip 8.00 HSPF Split DX 11.5 SEER 111.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Required Na Yes 0.0 kW ConslaM Volume 1 No No Constant T ConstantTemp—, n/a Air Balance Auto No Economim 65 cfrn Heat Pt n 8.00 HSPF Split DX 11.5 SEER / 11.0 EER TRANE 4TWR2018A1 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No I CODE TABLES: Enter code kom table below into columns above. HEAT PUMP THERMOSTAT? y::_ye TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both y Enter Number of Isolation Zones. 1: Inlet Vanes P: Variable Pitch V. VFD O: OC: Curve ther VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? OUTDOOR DAMPER ECONOMIZER OA CFM VENTILATION HIGH EFFICIENCY? B: Air Balance C: Outside Air CerL M: Out. Air Measure D: Demand Control N: Natural A: Auto G Gravity A.• Air : Water N: Not Required C: Economizer Control See Section 144(e� Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH3. PIPE INSULATION REQUIRED PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILJNGIROOF SPACE O FIELD-F r Building DepartmentOnly NOTES-- Run Initiation Time: 01/12/05 07:39:18 Run Code: 11055"358 EneWiPro 3.1 Sy EnegNSoR User Number: 5863 .lob Number 04088 Page:102 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 YSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R VALUE COOLING DUCT LOCATION RVALUE VERIFIED SEALED DUCTS IN CEILING/ROOFSPACE MECHANICAL SYSTEMS Double Queen 138 Double Queen 140 1 Double Queen 143 RIGHT Pro9mmmable Switch Heating & Coofina Required n/a Yes 0.0 kw Constant Volume No No Constw t Temp Consiarrt Temp n/a Air Balance Auto No Economizer 79 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER /11.0 EER TRANE 4TWR2018A7 Yes Yes Duds in Attic 4.2 Duds in Attic 4.2 No Programmable Switch Heatim & GoofiM Required Ma Yes 0.0 kW Constant Vokune No No Constant Temp Constant Temp n/a Ayr Balance Auto No Economizer 86 cfm Heat Pump 8.00 HSPF Split DX 11.5 SEER 110.9 EER TRANE 4TWR2024AI Yes Yes Ducts in Attic 42 Ducts in Attic 4.2 No Pr rrammable Switch Heating &Cook R uired Na Yes OD kW Constant Volume No No Constant Temp Constant Temp n/a Air Balance Auto No Economizer 128 cfm Heat Pum 8.20 HSPF Split DX 11.5 SEER 110.4 EER TRANE TFBO4018 Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code front table below into cok mts above. EnergyPro 3.1 By EnergySoft User Number: 58M Job Number: 04088 Page:103 of 126 CERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAME DATEHomewood Suites Hotel W28/2005 WY —STEM FEATURES SYSTEM NAME MECHANICAL SYSTEMS Double Queen 142 CODE TABLES: Enter code fivm table below unto columns above. HEAT PUMP THERMOSTAT? Y• Yes TIME CONTROL SETBACK CTRL ISOLATION ZONES FAN CONTROL ELECTRIC HEAT.? S: Prog. Switch O: Cccu'anncy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT ICOOL? HEAT AND COOL SUPPLY RESET? N: No VENTILATION OUTDOOR DAMPERLNot NOMIZER O.A. CFM HIGH EFFICIENCY? 8: Air Balance C: Outside Air Cert. M: Out Air Measure D. Demand Control N• Natural A: Auto G: Gravity er Required nomizer See Section e S Enter Outdoor Air FM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED I)t1CT'S IN CEILINGIROOF SPACE MOTES TO FIELD - For Suilding DeeRartment Use Only Run Initiation Time: 01112/05 07:39:18 Run Code: 1105544358 EnergyPro 3.1 By Entrg 6a User Number: 5863 Job Number:04088 Page:104 of 126 LIGHTING CONTROL CREDIT WORKSHEET LTG-3 1 PROJECT NAME Homewood Suites Hotel DATE 2/28/2005 ORKSHEET a a © o o a a o a PLANS REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR CONTROL CREDIT G x H) ROOM # ZONE ID LIGHTING CONTROL DESCRIPTION ROOM RATIO* GLAZING VLT Corridor 73 Automatic Time switch 340 68 0.05 3 Corridor 73 Automatic Time switch 340 185 0.05 9 Hotel Storage utomatic Time Switch 160 132 0.05 7 Corridor 114 Automatic Time Switch 700 170 0.05 8 Corridor 114 Automatic Time switch 700 518 0.05 26 Elevator Lobby 110 Automatic Time swatch 175 62 0.05 3 Elec Equip 109 AutomabcTime switch 114 62 0.05 3 lee 108 utomatic Time switch 66 62 0.05 3 Corridor 107 Autonuffic Tine switch 850 238 0.05 12 Corridor 107 Automatic Time Switch 850 777 0.05 39 Coin Laundry Automatic Time switch 165 124 0.05 6 Corridor 97/99 Automatic Time Switch 800 170 0.05 8 Corridor 97/99 Aaornatic Time Switch 800 703 0.05 35 corridor 93 Right Automatic Time switch 600 102 0.05 5 Corridor 93 Right okutornaticTime swatch 600 481 0.05 24 Corridor 105 Automatic Tone switch 800 204 0.05 10 Corridor 105 Okutomatic Time Switch 800 703 0.05 35 Corridor 93 Left Automatic Time Switch 600 170 0.05 8 Corridor 93 Lett Autorriatic Time switch 600 444 0.05 22 Elevator Lobby 103 Automatic Time Switch 401 62 0.05 3 Elec Equip 102 Automatic Time switch 62 62 0.05 3 Corridor 78 Automatic Time Switch 800 204 0.05 10 Corridor 78 Automatic Time switch 800 703 0.05 35 Corridor 74 Automatic Time switch 600 170 0.05 8 Corridor 74 AutomaticTime switch 600 444 0.05 22 Elevator Lobby 76 Automatic Time Switch 40 621 0.05 3 Elec Equip 75 Automatic Time switch 62 62 0.05 3 Corridor 49 Automatic Time switch 800 204 0.051 10 Corridor 49 1 Automatic Time switch 800 703 0.05 35 PAGE TOTAL 403 For windows, use the Window Wall Ratio for the room. For skylights, use the Skylight -to -Roof ratio for the room. BUILDING TOTAL 1 238 Enter on LTG-1 and 2: Actual Lighting Power calculation. Run In" ' tion Time: 0 12l05 0 •39. 8 Run Code: 1105 358 EnergyPro 3.1 By EnergySoft User Number 5863 Job Number: 04088 Page:105 of 126 LIGHTING CONTROL CREDIT WORKSHEET LTG-3 PROJECT NAME 16��TE2/28/2005 Homewood Suites Hotel ORKSHEET o © a o 0 o a A o PLANS ROOM AREA DAYLIGHTING WATTS OF CONTROL LIGHTING ADJUST. CONTROL CREDIT WATTS ROOM # LIGHTING CONTROL ROOM GLAZING ZONE ID DESCRIPTION REF_ (SF) RATIO` VILT LIGHTING FACTOR GAXT Corridor 18 Automatic Time Switch 600 170 0.05 8 Corridor 18 Automatic Time Switch 600 444 0.05 22 Elevator Lobby 47 Automatic Time Switch 40 1 621 0.051 3 Elevator Equip 46 Autoff vatic Time Switch 62 62 0.05 3 Elevator Lobby 54 AutomaticTime switch 151 62 0.05 3 Elevator Equip 53 AidomaticTime Switch 114 62 0.05 3 Ice 52 Automatic Time Switch 66 62 0.05 3 Dome corridor Atutomatic Time Switch 250 185 0.05 9 Corridor 51 AutornaticTime Switch 850 238 0.05 12 Corridor 5' Atitomatic Time Switch 850 777 0.05 39 Corridor 80 Automatic Time Switch 850 238 0.05 12 Corridor 80 Automatic rim Switch 850 777 0.05 39 Corridor 85,87 Automatic Time Switch 700 170 0.05 8 Corridor 85,87 Automatic Time Switch 700 518 0.05 26 Corridor 71 Automatic Time Switch 800 170 0.05 8 Corridor 71 AiAomabc Time Switch 800 703 0.05 35 Corridor 67 Automatic Time Switch 600 102 0.05 5 Corridor 67 Automatic Time Switch 600 481 0.05 24 Admin Automatic Tim switch 130 186 0.05 9 Convenience Store Automatic Time Switch 120 124 0.05 6 General "airAutomaticTime Switch 200 124 0.05 6 PBX Automatic Time switch 75 93 0.05 5 Pantry Automatic Time switch 3251 555 0.05 28 Food Prep Automatic Time Switch 325 372 0.05 19 Registration Automatic Time Switch 200 222 0.05 11 Registration Automatic Time Switch 200 74 0.05 4 Sales Director Automatic Time Switch 195 124 0.05 6 Work ATM Automatic Time Switch 95 62 0.051 3 Meeting Room 2 Automatic Time Switch 800 868 0.051 43 PAGE TOTAL 404 * For windows, use the Window Wall Ratio for the room. For skylights, use the Skylight -to -Roof ratio for the room. Enter on LTG-1 BUILDING and 2: Actual TOTAL Lighting Power 1 238 calculation. Run Initiation TiMe: 01/ 21 5 07:39.18 Run Code: 11055"358 EnergyPro 3.1 By EnergySoft User Number 5863 Job Number: 04088 Page:106 of 126 LIGHTING CONTROL CREDIT WORKSHEET LTG - PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 ORKSHEET o a a a o a a o 0 PLANS ROOM AREA DAYLIGHTING WATTS OF CONTROL LIGHTING ADJUST. CONTROL CREDIT DDIITS ROOM # LIGHTING CONTROL ROOM GLAZING ZONE ID DESCRIPTION REF. (SF) RATIO* VLT LIGHTING FACTOR G X H Exec center Automatic Time switch 110 124 0.05 6 Meeting Room 1 Automatic Time Switch 900 868 0.05 43 Lodge Automatic Time Switch 1,700 1,258 0.051 63 Linen Storage Automatic Time Switch 118 93 0.05 5 Elec. 65 Automatic Time Switch 155 132 0.05 7 House KP Automatic Time switch 152 93 0.05 5 House KP Automatic Time Switch 152 62 0.05 3 Corridor 55' b7' 60 Automatic Time Switch 700 170 0.05 8 Corridor 55, 57, 6o Automatic Time Switch 700 518 0.05 26 LaurKtry Automatic Time Switch 600 837 0.05 42 Exercise Room Automatic Time Switch 800 496 0.05 25 Entrance Lobby Automatic Time Switch 850 740 0.05 37 Equip. Storage 44 Automatic Time Switch 100 102 0.05 5 Equip. Storage 44 Automatic Time Switch 100 481 0.05 24 Unisex Bathroom Automatic Time Switch 77 64 0.05 3 Unisex BathRaiAutomatic Time Switch 77 124 0.05 6 Coin Laundry Automatic Time Switch 139 124 0.05 6 women's Restroom Automatic Time Switch 234 64 0.05 3 Women's RestrQom AutornaticTime Switch 234 124 0.05 6 Men's Restroom Automatic Time Switch 234 64 0.05 3 Men's Restroom Automatic Time switch 234 124 0.05 6 Elevator Lobby 37 Automatic Time Switch 40 62 0.05 3 Elevator Equip 36 Automatic Time Switch 62 62 0.05 3 Corridor 41 Automatic Time Switch 743 170 0.05 8 Corridor 41 Automatic Time Switch 743 703 0.05 35 Corridor 26 Automatic Time Switch 550 102 0.05 5 Corridor 26 Automatic Time Switch 550 481 0.05 24 Board Room Automatic Time Switch 433 372 0.05 19 PAGE TOTAL 431 * For windows, use the Window wall Ratio for the room. For skylights, use the Skylight4o-Roof ratio for the room. Enter on LTG4 BUILDING and 2: Actual Lighting TOTAL Power 1 238 calculation. Run Initiation Time: 01112/05 07.39: 8 Run Code: 1 05N4358 EnergyPro 3.1 By EnergySoft User Number 5863 Job Number: 04088 Page:107 of 126 cf-ueN1['_AL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 ROJECT NAME , _ _ , , _,_, 2/28/2005 , 18A1 Corvsw t Volume18 Constant Volume030A1 Constant Volume8F300B' Constant Volume4F100B` I Constart Volume8F1006' Cor►stant Volume0F100B' Constant Volume42F300B' Constant Volume0D4 Constant Volume Through 1,000 Through 1,400 Motorl Drive Eff. Eff. CFM 77.0% 97.0% none 77.0% 100.0% none 77.0% 100.0% none 77.0% too.0% none 77.0% 100.0% none 77.0% 100.0% none 77.0% 100.0% none 77.0% 100.0% none 77.0% 100.0% none Run Initiation Time• 01i12105 07.39.18 Run Cod 3.1 By EnergySoft User Number. 5863 Job Number 04088 s Motor I Drive 10s of 126 System Name System T HEATING Aux. kW Eff. Sensible a.wunv Efficienc Economizer Type BANE TWA090A300E` Split DX 2 62,900 0. 8.00 HSP 82,700 64, 0.3 EER No Economizer BANE TWA120A300E` Split DX 2 91,400 0.0 8.00 HSPF 117,100 85, 0.1 EER No Economizer TRANE Split DX 1 80,100 0.0 8.00 HSPF 58,400 45,30C 9.7 SEER 19.0 EER No Economizer TRANE 4TWR2036A1 SW DX 2 24,100 0.0 8.10 HSPF 28,500 26,50CII.5 SEER / 11.1 EER No Economizer TRANE 4TWR2024AI Split DX 69 12,700 0.0 8.00 HSPF 18,800 17, 1.5 SEER / 10.9 EER No Economizer TRANE Split DX 1 51,6W 0.0 8.00 HSPF 48,9W 40,50010.5 SEER / 9.5 EER No Economizer cl IEKN v CAM I I RFTIIRN FAN System Name Fan T Motor location CFM BHP Motor Eff. Drive Eff. CFM BHP I Motor Eff. Drive Eff. TRANE TWA090A300E' Constant Volume Draw Through 3,000 0.04 77.0% 100.0% no TRANE TWA120A300E` stant Volume raw -Through 4,000 0.04 77.0% 100.0% none TRANE Constant Volume Draw -Through 2,000 0.04 77.0% 100.0% none TRANE 4TWR2036A1 Constant Volume Draw-Through1,200 0.04 77.0% 100.0% none TRANE 4TWR2024A1 Constant Volume Draw Through 800 0.03 77.0% 100.0% none TRANE Constant Volume raw -Through 1,920 0.04 77.0% 100.0% none EnergvPro 3.1 By EnergySoft User Number 5863 Job Number 04088 Page:109 of 126 ECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 NAME DATE CFM I BHP I MEff. I E e I I TYPe I OW- 0 MR, Muu nuawa.v.. . ■...... ..... -- - - - - - - -- Page:110 of 126 3.1 By ErwxgySofl User Number 5863 Job Number 04088 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION o ©© o 0 0© o 0 o a AREA BASIS OCCUPANCY BASIS READ O.A (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Corr. 73/Hotel Stor. 660 0.15 99 99 124 AC-1 Totail 99 124 Guestroom 0.15 128 128 128 Double Queen 143 LEFT ;;8J5 Total 128 128 Guestroom 0.15 48 48 48 Double Queen 118 LEFT Take 48 48 Guestroom 3 0.15 48 48 48 222 2 Bed Double Queen LFT Total 48 48 Guestroom 230 0.15 34 34 35 247 2 Bed Queen LEFT Total 34 35 Guestroom 0.15 49 49 49 249 ACC 2 Bed LEFT Tom 49 ` 9 Guestroom L570 0.15 86 86 86 326 2 Bed Double Queen RT Total ' 86 86 Guestroom 0.15 33 33 33 3512 Bed Queen RIGHT Total 33 33 Guestroom 420 0.15 63 63 63 353 ACC 2 Bed LEFT Tom 63 63 Corr. 1071114 1,905 0.15 286 286 545 RTU-12 Total 286 545 Corr. 97/99/93 Right 1,565 0.15 235 235 470 RTU-11 Total 235 470 Corr. 105/93 Left 1 0.15 225 225 441 RTU-10 T�I 2' 441 Gorr.74178 1,502 0.15 2251 225 441 RTU-9 Total 225 441 Corr. 18/49 1,662 0.15 249 249 449 RTU-8 Totall 249 449 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EnergWro 3.1 8v EnerwSoft User Number. 5863 Job Number. 04088 Page:I I I of 126 J MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION o ©© o 0 0© I o a o AREA BASIS OCCUPANCY BASIS kEQ'D O.A (MAX OF D OR G) DESIGN AIR CFM VAV MIN. RATIO RANS FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Corr. 51 /Dome Corr. 1,591 0.15 239 239 372 RTU-7 Total 239 372 Corr. 80 M87 1, 0.15 233 233 465 RTU-6 Total 233 465 Corr. 67171 1,400 0.15 210 210 420 RTU-2 Total 210 420 Pantry/Offices 1, 0.50 832 1 832 370 463 AC-8 Total 832 370 Meeting Roan 2 0.50 400 400 120 280 AC-7 Total 400 120 Meeting Room 1 1,010 0.50 505 505 168 337 AC-6 Total 505 168 Lodge 1,700 0.50 850 1 850 3,423 AC-10 Total 850 3,423 Corr.55/57/60/Laundry 1,885 0.15 283 283 445 RTU5 Total 283 445 Exercise Room 800 0.15 1201 120 120 Exercise Room Total 120 120 Entrance Lobby 0.15 128 1 1,711 AC-9 Total 128 1,711 204 Employee Break Roan 0.50 291 291 87 Employee Break Room Total 291 87 Corr. 26/41 /Restroorns 2, 0.15 351 351 631 RTU-1 Total 351 631 Board Room 433 0.50 216 216 65 152 Board Room Total 216 65 Guestroom 473 0.15 71 71 71 232 I6ng Total 71 7111 C E I K Minimum Ventilation Rate per Section 121, Table 1 -F_ Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J)_ EnemvPro 3.1 By EnergvSoft User Number 5863 Job dumber: 04088 Page:112 of 126 MECHANICAL VENTILATION MECH-3 PROJECT ��� DATE uites Hotel 2/28/2005 MECHANICAL VENTILATION a ©© a o o© o o a o AREA BASIS OCCUPANCY BASIS REQ'D OA (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM D. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MI CFM (EXF) Guestroom 459 0-15 69 69 69 Studio 121 Total 69 69 Guestroom 573 0.15 86 86 86 354 ACC Studio Tel 86 86 Guestroom 533 0.15 80 80 80 353 ACC 2 Bed RIGHT Total 80 80 Guestroom 59 0.15 89 89 89 351 2 Bed Queen LEFT Total 89 89 Guestroom sm 0-15 Sol 80 80 352 Double Queen Total 801 80 Guestroom 532 0.15 80 80 80 350 Double Queen Total 80 80 Guestroom 571 0-15 861 86 86 348 Double Queen Totall 86 86 Guestroom 532 0.15 80 801 80 346 Double Queen Total 80 80 Guestroom 433 0.15 651 65 65 344 Studio Total 65 65 Guestroom 0.15 65 65 65 343 Studio Total 65 65 Guestroom 433 0.15 651 65 65 342 Studio Total 65 65 Guestroom 0-15 65 65 65 341 Studio 7W2 Total 65 65 Guestroom 0.15 801 80 80 340 Double Queen Total 80 80 Guestroom 532 0.15 80 80 80 339 Double Queen Total 80 80 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air- Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H- J). EneravPro 3.1 By EnerovSoft user Number: 5863 Job Number: 04088 Page:113 of 126 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION o ©© o a a© a o 0 0 AREA BASIS OCCUPANCY BASIS REQ'D O.A (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 53 0.15 80 80 80 338 Double Queen Total 80 80 Guestroom 532 OA 5 80 80 80 337 Double Queen Total 80 80 Guestroom 473 0.15 711 F- 71 71 336 long Total 71 71 Guestroom 47 0.1 71 71 71 3r IOng Total 71 71 Guestroom 473 0.15 71 71 71 334 King Total 71 71 Guestroom 4731 0.15 71 71 71 333 }Ong Total 71 71 Guestroom 47 0.15 71 71 71 332 King Total 71 71 Guestroom 47 0.15 71 711 71 331 IOng Total 71 71 Guestroom 453 0.15 68 68 68 330 Studio Totall 68 68 Guestroom 453 0.15 68 68 68 329 Studio Total 68 68 Guestroom 453 0.15 68 68 68 328 Studio Total 68 68 Guestroom 459 0.15 69 69 69 327 Studio Total 69 69 Guestroom 405 0.15 61 61 61 326 2 Bed Double Queen LFT Total 61 61 Guestroom 486 0.151 731 73 73 E]EI 3231Ong Total 73 73 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greeter than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greeter than or equal to (H-J). EneravPro 3.1 By EnercwSoft user Number. 5863 Job Plumber 04088 Page:114 of 126 MECHANICAL VENTILATION MECH-3 PROJECT NAME ATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION o ©© a o o© o a o 0 AREA BASIS OCCUPANCY BASIS REQ'D O.A (MAX OF D OR G) DESIGN AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (FxFl Guestroom 527 0.15 79 79 79 324 Fong I Total 79 79 Guestroom 554 0.15 83 83 83 3211Qng Total 83 83 Guestroom 654 0.15 98 98 98 322 King Totall 981 98 Guestroom 7 0.15 109 109 109 300 Fling Total 109 109 Guestroom 657 0.15 99 99 99 RTU-3 Total 99 99 Guestroom 657 0.1 99 99 99 RTU-4 Tel 99 99 Guestroom 554 0.15 83 83 83 3031Qng Total 83 83 Guestroom 654 0.15 98 98 98 302IQng Totall 981 98 Guestroom 473 0.15 711 71 71 305 long Total 71 71 Guestroom 527 0.15 79 79 79 304 FQng Total 79 79 Guestroom 622 0.15 93 93 93 306 Double Queen Total 93 93 Guestroom 622 0:15 93 93 93 308 Double Queen Totall 931 93 Guestroom 475 0.15 71 71 71 309 Studio Total 71 71 Guestroom 453 0.15 68 68 68 310 Studio Total 68 68 C E 1 K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EnerovPro 3.1 By EnergvSoft User Number. 5863 Job Number: 04088 Page:115 of 126 MECHANICAL VENTILATION MECH-3 NAME Homewood Suites Hotel MECHANICAL VENTILATION DATE o ©©© o o© a o 0 0 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREACFM (SF) PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 453 0.15 68 68 68 311 Studio Total 68 Guestroom 453 0.15 68 68 68 312 Studio Total 68 68 Guestroom 545 0.15 82 82 82 314 IGng Comer Totall 82r7f Guestroom 4 0.15 71 71315King Total 71 Guestroom 473 0.15 711 71 71 316IGng Totall 71 71 Guestroom 473 0.15 71 71 71 317 King Total 71 71 Guestroom 473 0.15 71 71 71 318 IGng Total 71 71 Guestroom 57 0.15 861 86 86 250 ACC Studio Totall 86 86 Guestroom r--625 0.15 94 1 94 94 249 ACC 2 Bed RIGHT Total 94 94 Guestroom 580 P580.15 87 87 87 247 2 Bed Queen RIGHT Total 87r8o Guestroom 53 0.15 80 80 248 Double Queen Total 80 Guestroom 532 0.151 80 80 80 246 Double Queen Total 80 80 Guestroom 571 0.15 86 86 86 244 Double Queen Totall 86 86 Guestroom 532 0.151 80 80 80 242 Double Queen Total 80 80 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EneravPro 3.1 BY EnergvSoB User Number: 5863 Job Number:04088 Page:116 of 126 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION a ©© o o a a o 0 0 0 AREA BASIS 1 OCCUPANCY BASIS REQM OA (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 433 0.15 65 65 65 240 Studio Total 65 Guestroom 433 0.15 65 65 65 239 Studio Total 65 65 Guestroom 433 0.1565 65 65 237 Studio Totalr65 65 Guestroom 0.1 65 65 238 Studio Total 65 Guestroom 532 0.1580 80 80 236 Double Queen Total 80 Guestroom 0.15 80 V 80 235 Double Queen Total 80 Guestroorn 0.15 80 80 80 233 Double Queen Towl 801 80 Guestroom 532 0.15 80 80 80 234 Double Queen Total 80 80 Guestroom 473 0.15 71 71 71 231 IGng Totall 71 71 Guestroom 47 0.15 71 71 71 227 }Ong Total 71 71 Guestroom 473 0.15 711 71 71 229IGng I I Totdj 71 71 Guestroom 473 0.15 71 71 71 230 Icing ;Total 71 71 Guestroom 473 O. t 5 71 71 71 228 King Total 71 71 Guestroom 453 0.15 68 6868 225 Studio Total 68 68 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density, Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EnerpyPro 3.1 By EnergySoft User Number: 580 Job Number: 04088 Page:117 of 126 -1 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION o © a© o o© a o 0 0 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B X C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 453 0.15 68 68 68 226 Studio Totall 68 68 Guestroom 4590.15 69 69 69 223 Studio Total 69 69 Guestroom 453 0.15 68 w 68 224 Studio Totall 68 68 Guestroom 650 0.15 98 98 98 222 2 Bed Double Queen RT Total 98 98 Guestroom 486 0.15 73 73 73 219 King Totall 73 73 Guestroom 52 0.15 79 79 79 220 King Total 79 79 Guestroom 554 0.15 83 83 83 217 King Total 83 83 Guestroom 0.15 98 98 98 218 King Total 98 98 Guestroom 473 0.15 71 71 71 203 King Totall 71 71 Guestroom 554 0.15 831 83 83 201 King I Total 83 83 Guestroom 654 0.15 98 98 98 200 King Totall 98 98 Guestroom 527 0.15 79 791 79 202 King Total 79 79 Guestroom 622 0.15 931 93 93 204 Double Queen Totall 93 93 Guestroom 624 0.15 94 94 94 206 ACC-DQ Total 94 94 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Effected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-1). EneravPro 3.1 By EneravSoft User Number 58M Job Number: 04088 Page:118 of 126 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel I 2/28/2005 MECHANICAL VENTILATION a ©© a o o© o o a o AREA BASIS OCCUPANCY BASIS REQV OA (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAVTRANS- MIN. RATIO FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SI= MIN. CFM (B a C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 475 0.15 71 71 71 207 Studio Totall 71 71 Guestroom 453 0.15 68 1 68 68 208 Studio Total 68 68 Guestroom 453 0.15 68 68 68 209 Studio Total 68 68 Guestroom 0.15 68 68 68 210 Studio Total68 Guestroom 545 0.15 82 82 82 2121Gng Comer Total 82 82 Guestroom 47 0.15 71 71 71 213 King Totall 711 71 Guestroom 473 0.15 71 71 71 214 King Total 71 71 Guestroom 47 0.15 71 71 71 216 King Totall 711 71 Guestroom 473 0.15 711 71 71 215 ling Total 71E72 Guestroom 0.15 72 72 ling 114 Totall 721 72 Guestroom 480 0.15 721 72 72 King 112 Total 72 72 Guestroom 480 0.15 72 72 72 King 113 Total 721 72 Guestroom 480 0.15 721 72 72 King 111 Total 72 72 Guestroom 5511 0.15 83 83 83 Kling Comer 30 1 Total 83 83 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-!). EnergyPro 3.1 By EnergySoft User Number. 5863 Job Number 04088 Page:119 of 126 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel I 2/28/2005 MEC14AN CAL VENTILATION a © o 0 0 0© a a o 0 AREA BASIS OCCUPANCY BASIS REQ`D O.A (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (8 x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 456 0.15 68 68 68 Studio 107 Total 68 68 Guestroom 0.15 68 68 68 Studio 108 Totall 68 68 Guestroom 456 0.15 68 681 68 Studio 106 Total 68 68 Guestroom Wq 0.15 901 90 90 ACC Double 104 Totall 90 90 Guestroom 600 0.15 90 901 90 ACC Double 102 Total 90 90 Guestroom 5 0.1 79 79 79 Icing 100 Total 79 79 Guestroom 528 0.15 79 79 79 King 116 Total 79 79 Guestroom 760 0.15 114 114 114 Double Queen 118 RIGHT Total 114 114 Guestroom 475 0.15 711 711 71 King 115 Total 71 71 Guestroom 456 0.15 68 68 68 Studio 123 Totall 68 68 Guestroom 456 0.15 681 681 68 Studio 120 Total 68 68 Guestroom 456 0.15 68 68 68 Studio 122 Totall 68 68 Guestroom 480 0.15 721 721 72 Icing 125 Total 72 72 Guestroom 480 0.15 72 72 72 King 127 Total 72 72 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). I EneravPro 3.1 By Erww4oft User Number. 580 Job Number 04088 Page:120 of 126 1 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Homewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION o © a o 0 0 0 0 0 0 0 AREA BASIS OCCUPANCY BASIS REQ'D OA (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B z C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (EXF) Guestroom 480 0.15 72 72 72 long 129 1 Total 72 72 Guestroom 480 0.15 72 72 72 IQng 124 Total 72 72 Guestroom 0.15 721 72 72 lgng 126 Total 72 72 ,Guestroom 0.15 72 72 72 IQng 128 Total 72 72 Guestroom 5291 0.15 79 79 79 Double Queen 133 Total 79 79 Guestroom 5 0.15 79 79 79 Double Queen 131 Total 79 79 Guestroom 5291 0.15 79 79 79 Double Queen 130 Totall 79 79 Guestroom 529 0.15 791 791 79 Double Queen 132 Total 79 79 Guestroom 432 0.15 65 65 65 Studio 137 Totall 65 65 Guestroom 4M 0.15 65 1 651 65 Studio 135 Total 65 65 Guestroom 4321 0.15 65 65 65 Studio 134 Totall 65 65 Guestroom 432 0.15 65 651 65 Studio 136 Total 65 65 Guestroom 5291 0.15 79 79 79 Double Queen 138 Total 79 79 Guestroom 575 0.15 861 86 86 Double Queen 140 Tel 86 86 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 101997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Arc includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EneruvRo 3.1 Ov EneravSoft User Number: 580 Job Number 04088 Page:121 of 126 1 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATEHomewood Suites Hotel 2/28/2005 MECHANICAL VENTILATION a © o 0 0 0 0 0 0 0 0 AREA BASIS OCCUPANCY BASIS REQ'D O.A (MAX OF D OR G) DESIGN OUTDOOR AIR CFM VAV MIN. RATIO RANS FER AIR ZONEISYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) Guestroom 851 0.15 128 128 128 Double Queen 143 RIGHT Total 128 128 Guestroom 529 0.15 79 79 79 Double Queen 142 Total 79 79 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H-J). EnergWro 3.1 By EnemySoft User Number 5863 Job Number 04088 Page:122 of 126 ENVELOPE MANDATORY MEASURES ENV-MM NAME Homewood Suites Hotel DATE 2/28/2005 DESCRIPTION Designer Enforcement § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. 0 § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. 0 § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U value according to NFRC procedures. § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number: 580 Job Number: 04088 Page:123 of 126 LIGHTING MANDATORY MEASURES LTG-MM I� IcLrilzi Homewood Suites Hotel DATE 2128/2005 DESCRIPTION Designer Enforcement n § 13l(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. § 131(d)2Override for Building Lighting Shutoff: The automatic building shutoff system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X❑ § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. n§ 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. n§ 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting_ Display lighting shall be separately switched on circuits that are 20 amps or less. a§ 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:124 of 126 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM NAME Homewood Suites Hotel DATE 2/28/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies § 111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. 0 § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space condiitioning system shall be installed with one of the folk)wing: a§ 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accesshile manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4-hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling ttuerrnostat setpoint. 0 § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that atlow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees p or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 6 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. a§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoff User Number. 5863 Job Number. 04088 Page:125 of 126 (MECHANICAL MANDATORY MEASURES Part2 of 2 MECH-MM I PROJECT NAME Homewood Suites Hotel DATE 2/28/2005 Description Designer Enforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(f)4 Another method approved by the Commission. Service Water Heating Systems § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallonsicycle (non -circulating system). Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 5863 Job Number: 04088 Page:126 of 126