HomeMy WebLinkAboutBRES2022-1065BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Project Designer:
Report Prepared by:
Job Number:
Date:
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software – www.energysoft.com.
45175 Panorama Dr. Suite E
CASHCLA DESIGN & ASSOCIATES
Palm Desert, Ca 92260
(760) 272-9117
77800 Calle Nogales
Mr. Gary Spackman
La Quinta, CA 92253
P.O. Box 1018
Santiago Lopez-Ocampo
SLO
La Quinta, Ca
760.485.8927
LQ112122 - Rev032023
3/20/2023
05/02/2023Deisy Mendez
BRES2022-1065
2373SF SINGLE FAMILY
DWELLING
[VB/RES-3/NFPA/13D]
WITH GARAGE OF
486SF. THIS PERMIT
DOES NOT INCLUDE PV
SYSTEM, POOL, SPA,
BLOCK WALLS,
DRIVEWAY APPROACH
OR SIMILAR EXTERIOR
STRUCTURES. 2019
CALIFORNIA BUILDING
CODES.
TABLE OF CONTENTS
Form MF-1R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Cover Page
Table of Contents
Form CF1R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
15
19
1
2
3
14
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 1 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
GENERAL INFORMATION
01 Project Name Mr. Gary Spackman
02 Run Title Title 24 Analysis
03 Project Location 77800 Calle Nogales
04 City La Quinta 05 Standards Version 2019
06 Zip code 92253 07 Software Version EnergyPro 8.3
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)180
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 3
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2373 19 Glazing Percentage (%)13.02%
20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 2 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
ENERGY DESIGN RATING
Energy Design Ratings Compliance Margins
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 47.4 22.7
Proposed Design 46.3 21.6 1.1 1.1
RESULT:3:COMPLIES
1: Efficiency EDR includes improvements to the building envelope and more efficient equipment
2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
3: Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 4.47 kWdc
•PV System resized to 4.47 kWdc (a factor of 4.475) to achieve 'Standard Design PV' PV scaling
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 1.01 2.03 -1.02 -101
Space Cooling 71.63 68.86 2.77 3.9
IAQ Ventilation 3.44 3.44 0 0
Water Heating 8.42 7.36 1.06 12.6
Self Utilization/Flexibility Credit n/a 0 0 n/a
Compliance Energy Total 84.5 81.69 2.81 3.3
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
4.47 NA Standard Fixed none true 150-270 n/a n/a <=7:12 96 98
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 3 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Cool roof
•Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Indoor air quality ventilation
•Kitchen range hood
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•Pipe Insulation, All Lines
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Mr. Gary Spackman 2373 1 3 1 0 1
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 4 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Whole House Conditioned HVAC System1 2373 8 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Fr/S Whole House R-21 Wall + 1 EPS 180 Front 525.33 60 90
Le/W Whole House R-21 Wall + 1 EPS 270 Left 291.66 18 90
Re/N Whole House R-21 Wall + 1 EPS 0 Back 700 147 90
Ri/E Whole House R-21 Wall + 1 EPS 90 Right 460 84 90
Wall Between Garage &
Liv Whole House R-21 Wall - Interior n/a n/a 4441.25 21.28 n/a
Roof Whole House R-38 Roof + RB - Tile n/a n/a 928 n/a n/a
Roof 2 Whole House R-38 Roof + RB - Tile n/a n/a 112 n/a n/a
Roof 3 Whole House R-38 Roof + RB - Tile n/a n/a 528 n/a n/a
Roof 4 Whole House R-38 Roof + RB - Tile n/a n/a 805 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Whole House Attic RoofWhole House Ventilated 0 0.37 0.92 Yes Yes
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 5 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
3050 @ GRoom Window Fr/S Front 180 1 15 0.26 NFRC 0.24 NFRC Bug Screen
3050 @ GRoom 2 Window Fr/S Front 180 1 15 0.26 NFRC 0.24 NFRC Bug Screen
3050 @ GRoom 3 Window Fr/S Front 180 1 15 0.26 NFRC 0.24 NFRC Bug Screen
3080 @ Entry Window Fr/S Front 180 1 15 0.32 NFRC 0.29 NFRC Bug Screen
2040 @ Powder Window Le/W Left 270 1 8 0.27 NFRC 0.23 NFRC Bug Screen
2050 @ MBath Window Le/W Left 270 1 10 0.27 NFRC 0.23 NFRC Bug Screen
1060 @ MBath Window Re/N Back 0 1 6 0.26 NFRC 0.24 NFRC Bug Screen
4040 @ MBath Window Re/N Back 0 1 16 0.26 NFRC 0.24 NFRC Bug Screen
4026 @ MBath Window Re/N Back 0 1 10 0.26 NFRC 0.24 NFRC Bug Screen
2660 @ MBed Window Re/N Back 0 1 15 0.26 NFRC 0.24 NFRC Bug Screen
2660 @ MBed 2 Window Re/N Back 0 1 15 0.26 NFRC 0.24 NFRC Bug Screen
6046 @ Kitchen Window Re/N Back 0 1 27 0.26 NFRC 0.24 NFRC Bug Screen
(2)3080 @ Dining Window Re/N Back 0 1 48 0.32 NFRC 0.29 NFRC Bug Screen
2050 @ Bath2 Window Re/N Back 0 1 10 0.27 NFRC 0.23 NFRC Bug Screen
1630 @ Bath2 Window Ri/E Right 90 1 4.5 0.27 NFRC 0.23 NFRC Bug Screen
3050 @ Bed2 Window Ri/E Right 90 1 15 0.26 NFRC 0.24 NFRC Bug Screen
3050 @ Bed2 2 Window Ri/E Right 90 1 15 0.26 NFRC 0.24 NFRC Bug Screen
3080 @ Hallway Window Ri/E Right 90 1 15 0.32 NFRC 0.29 NFRC Bug Screen
3050 @ Bed3 Window Ri/E Right 90 1 15 0.26 NFRC 0.24 NFRC Bug Screen
3050 @ Bed3 2 Window Ri/E Right 90 1 15 0.26 NFRC 0.24 NFRC Bug Screen
1630 @ Bath Window Ri/E Right 90 1 4.5 0.27 NFRC 0.23 NFRC Bug Screen
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 6 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
2880 Garage Wall Between Garage & Liv 21.28 0.2
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft
2)Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction Heated
Slab-on-Grade Whole House 2373 0.1 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall + 1 EPS Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / R-4.2 0.05
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4.2 Sheathing
Exterior Finish: 3 Coat Stucco
R-21 Wall - Interior Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic RoofWhole House Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
R-38 Roof + RB - Tile
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025
Over Ceiling Joists: R-28.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 7 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
HERS Verified Pipe
Insulation credit
DHW Heater 1 (1)n/a None DHW Sys 1-hers-dhw
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
# of
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 1 0 0.95-UEF <= 200
kBtu/hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required Not Required
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 8 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
HVAC System1 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 2 2
01 02 03 04 05 06 07 08 09 10 11
HVAC - HEAT PUMPS
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER/CEER
Heat Pump System 1 Central split HP 2 9.2 32600 22820 16.5 13.5 Not Zonal
Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Required Yes Yes Yes Yes
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 9 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 10 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06 07
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness - SRE
IAQ Recovery
Effectiveness - ASRE
HERS Verification
SFam IAQVentRpt 99 0.35 Exhaust n/a n/a Yes
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Mr. Gary Spackman Calculation Date/Time:2023-03-20T10:25:38-07:00 (Page 11 of 11)
Calculation Description:Title 24 Analysis Input File Name:77800 Calle Nogales - Rev032023.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000
Schema Version: rev 20200901
Report Generated: 2023-03-20 10:26:30
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Santiago Lopez-Ocampo
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, CA 92247
2023-03-20 10:29:56
N/A
760-485-8927
Carlos Sanchez
CASHCLA Design & Associates
45-175 Panorama Dr, Ste E
Palm Desert, CA 92260
2023-03-20 11:06:34
N/A
760-272-9117
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
222-P010226435C-000-000-0000000-0000 2023-03-20 11:06:34 CalCERTS inc.
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type Single Family Addition Alone Date
Multi Family Existing+ Addition/Alteration
Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units
INSULATION Area
Construction Type Cavity (ft2) Special Features Status
FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor:
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Mr. Gary Spackman
77800 Calle Nogales La Quinta
0.23
3/20/2023
4
CA Climate Zone 15 2,373 1
Wood Framed
Slab
Wall
Demising
Roof
Unheated Slab-on-Grade
Wood Framed
Wood Framed Attic
2,373
1,668
4,420
2,373R 38
- no insulation -
R 20
R 21
New
New
New
NewCool Roof
Perim = 0'
Add=R-4.2
n/a
Front (S)
Front (S)
Left (W)
Rear (N)
Rear (N)
Rear (N)
Right (E)
Right (E)
Right (E)
9.0
45.0
15.0
18.0
89.0
48.0
10.0
15.0
60.0
0.270
0.270
0.260
0.320
0.270
0.260
0.320
0.320
0.260
0.23
0.24
0.29
0.23
0.24
0.29
0.29
0.24
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
New
New
New
New
New
New
New
New
New
16.5 SEER2Split Heat Pump Split Heat Pump9.20 HSPF NewSetback
AtticHVAC System DuctedDucted New8.0
All Pipes Ins (HERS)1 Small Instantaneous Gas 0.950 New
ID: LQ112122 - Rev032023 Page 14 of 19EnergyPro 8.3 by EnergySoft SoftwareUser Number: 5732
309 13.0%0.28
2019 Low-Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(01/2020)
Building Envelope Measures:
§ 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less
when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.*
§ 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a).
§ 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables
110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped.*
§ 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
gasketed, or weather stripped.
§ 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods
and Services (BHGS).
§ 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R.
§ 110.8(j): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
§ 150.0(a):
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood-frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value.
§ 150.0(c):
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or
have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls
must meet Tables 150.1-A or B.*
§ 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.*
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and
UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g).
§ 150.0(g)1: Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor
retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to § 150.0(d).
§ 150.0(g)2: Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation.
§ 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.*
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces.
§ 150.0(e)1: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)2: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device.*
§ 150.0(e)3: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control.*
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the California Energy Commission.*
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.*
§ 110.2(b):
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
§ 110.2(c): Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.*
§ 110.3(c)4:
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of
§ 110.3(c)4.
§ 110.3(c)6: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose
bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed.
§ 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except
appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters.*
§ 150.0(h)1:
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook,
Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards
Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2.
2019 Low-Rise Residential Mandatory Measures Summary
§ 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer
t
§ 150.0(h)3B: Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the
manufacturer’s instructions.
§ 150.0(j)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water-heating systems, must have
a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
§ 150.0(j)2A:
Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must
be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum
insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot
water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less
than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks,
buried below grade, and from the heating source to kitchen fixtures.*
§ 150.0(j)3:
Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes).
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a
Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve.
§ 150.0(n)1:
Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of
the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG
copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the
word “spare” and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker
for the branch circuit and labeled with the words “Future 240V Use”; a Category III or IV vent, or a Type B vent with straight pipe between the
outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base
of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour.
§ 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing
agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3: Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
§ 150.0(m)1:
CMC Compliance. All air-distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0
and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and
plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned
space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be
mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable requirements of UL
181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ¼
inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums
designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air.
Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause
reductions in the cross-sectional area.*
§ 150.0(m)2:
Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction,
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3: Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers.
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
§ 150.0(m)9:
Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed
to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular
foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non-porous layer between the inner core and outer vapor barrier.
§ 150.0(m)11:
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
§ 150.0(m)12:
Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or
equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure
drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.*
§ 150.0(m)13:
Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole
for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM
per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per
CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling
unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.*
2019 Low-Rise Residential Mandatory Measures Summary
Requirements for Ventilation and Indoor Air Quality:
§ 150.0(o)1: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation
and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1.
§ 150.0(o)1C:
Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with
other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates
determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C.
§ 150.0(o)1E:
Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in
accordance with Equation 150.0-B and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced
system is not used, all units in the building must use the same system type and the dwelling-unit envelope leakage must be ≤ 0.3 CFM at 50 Pa
(0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8.
§ 150.0(o)1F:
Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide
ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be
within 20 percent of the unit with the lowest airflow rate as it relates to the individual unit’s minimum required airflow rate needed for compliance.
§ 150.0(o)1G: Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2.
§ 150.0(o)2:
Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential
Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is
rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2.
Pool and Spa Systems and Equipment Measures:
§ 110.4(a):
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or
dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.*
Lighting Measures:
§ 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.*
§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A.
§ 150.0(k)1B:
Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
§ 150.0(k)1C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C.
§ 150.0(k)1D: Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an
output frequency no less than 20 kHz.
§ 150.0(k)1E: Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be
controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens.
§ 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
§ 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8.*
§ 150.0(k)1H: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated
temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
§ 150.0(k)1I:
Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to
comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no
more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed.
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.*
§ 150.0(k)2C: Interior Switches and Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually
turned ON and OFF.*
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer’s instructions.
§ 150.0(k)2E: Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to
comply with § 150.0(k).
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
2019 Low-Rise Residential Mandatory Measures Summary
§ 150.0(k)2G:
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it:
provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the
EMCS requirements of § 130.0(e); and meets all other requirements in § 150.0(k)2.
§ 150.0(k)2H: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)2I:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by an occupant sensor or a vacancy sensor providing automatic-off functionality. If an occupant sensor is installed, it must be
initially configured to manual-on operation using the manual control required under Section 150.0(k)2C.
§ 150.0(k)2J: Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for
dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.*
§ 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling-installed lighting systems.
§ 150.0(k)3A:
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either
§ 150.0(k)3Aii (photocell and either a motion sensor or automatic time switch control) or § 150.0(k)3Aiii (astronomical time clock), or an EMCS.
§ 150.0(k)3B:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances,
balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either § 150.0(k)3A or
with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots
or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by § 150.0(k)3B or § 150.0(k)3D must comply with
the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
§ 150.0(k)6A:
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be comply with Table 150.0-A and be controlled by an occupant sensor.
§ 150.0(k)6B:
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in
that building must:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
§ 110.10(a)1:
Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the
application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which
do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2: Low-rise Multifamily Buildings. Low-rise multi-family buildings that do not have a photovoltaic system installed must comply with the
requirements of § 110.10(b) through § 110.10(d).
§ 110.10(b)1:
Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access,
pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by
a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80
square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with
roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building
and have a total area no less than 250 square feet. For low-rise multi-family buildings the solar zone must be located on the roof or overhang of
the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the
building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone
requirement is applicable to the entire building, including mixed occupancy.*
§ 110.10(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must be oriented between 90 degrees and 300 degrees of true north.
§ 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
§ 110.10(b)3B:
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.*
§ 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
§ 110.10(c):
Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a
pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family
residences and central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system.
§ 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
§ 110.10(c) must be provided to the occupant.
§ 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
§ 110.10(e)2: Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric”.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
System Name Floor Area
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems COIL COOLING PEAK COIL HTG. PEAK
Heating System CFM Sensible Latent CFM Sensible
Output per System Total Room Loads
Total Output (Btuh) Return Vented Lighting
Output (Btuh/sqft) Return Air Ducts
Cooling System Return Fan
Output per System Ventilation
Total Output (Btuh) Supply Fan
Total Output (Tons) Supply Air Ducts
Total Output (Btuh/sqft)
Total Output (sqft/Ton) TOTAL SYSTEM LOAD
Air System
CFM per System HVAC EQUIPMENT SELECTION
Airflow (cfm)
Airflow (cfm/sqft)
Airflow (cfm/Ton)
Outside Air (%) Total Adjusted System Output
Outside Air (cfm/sqft) (Adjusted for Peak Design conditions)
Note: values above given at ARI conditions TIME OF SYSTEM PEAK
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
Mr. Gary Spackman 3/20/2023
HVAC System 2,373
2
32,600
65,200
27.5
37,000
74,000
6.2
31.2
384.8
0
0
0.00
0.0
0.0%
0.00
1,325
22,947
0
0
0
0
0
577
15,083
0
0
00
577
0
1,325
1,02761,613
86525,596
61,613
40,722
1,027 40,722
Lennox XP17-036-230*
Aug 3 PM Jan 1 AM
1,138 865 388
26 ºF
Outside Air
0 cfm
68 ºF 105 ºF
105 ºF
68 ºF 68 ºF
112 / 73 ºF 76 / 62 ºF 55 / 54 ºF
56 / 54 ºF
75 / 62 ºF76 / 62 ºF
0 cfm
Outside Air
46.8%
Heating Coil
16,236
Cooling Coil
SIDELINE® ELITE SERIES ELECTRIC FIREPLACE HEATER
Model # : 80036, 80037, 80038, 80042
OWNER’S MANUAL
Sideline® Elite Series 42”, 50”, 60”, 72”
Recessed Electric Fireplace
AC 110-120V 60Hz 1500W
WARNING
Read and understand this entire owner’s manual, including all safety
information, before plugging in or using this product. Failure to do so could
result in fire, electric shock, or serious personal injury.
CAUTION Keep this owner’s manual for future reference. If you sell or give this
product away, make sure this manual accompanies this product.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
2
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
3
Table of Contents
General Information ...................................................................................................................................................... 5
CSA Approval Listing Information ........................................................................................................................... 5
Fireplace Specifications............................................................................................................................................ 5
Serial Number Label ................................................................................................................................................. 5
Dimensional Drawings ............................................................................................................................................. 6
80036 – Sideline® Elite 50” Dimensions ............................................................................................................. 6
80037 – Sideline® Elite 60” Dimensions ............................................................................................................. 7
80038 – Sideline® Elite 72” Dimensions ............................................................................................................. 8
80042 – Sideline® Elite 42” Dimensions ............................................................................................................. 9
Unpacking Your Fireplace .......................................................................................................................................... 10
Parts and Hardware ............................................................................................................................................... 10
Unpacking and Setup .............................................................................................................................................. 10
Wiring ..................................................................................................................................................................... 11
Hard Wire Connection ............................................................................................................................................ 12
Installation................................................................................................................................................................... 13
Choosing Installation Location............................................................................................................................... 13
Removing The Glass Panel ..................................................................................................................................... 14
Recessed Installation .............................................................................................................................................. 15
Installing the Crystal Embers and Drift Wood Logs .............................................................................................. 18
Installing the Crystal Embers .............................................................................................................................. 18
Installing the Drift Wood Logs ........................................................................................................................... 18
Reinstalling the Glass Panel ................................................................................................................................... 19
Wall Mounted Installation ...................................................................................................................................... 20
Operating Fireplace ..................................................................................................................................................... 23
Power ...................................................................................................................................................................... 23
Methods of Operation ............................................................................................................................................. 23
Control Panel Functions ...................................................................................................................................... 24
Wireless Remote Control Functions ................................................................................................................... 25
Remote Control Operation ...................................................................................................................................... 27
Changing Remote Battery ................................................................................................................................... 27
Temperature Limiting Control ................................................................................................................................ 27
Care and Maintenance................................................................................................................................................. 28
Cleaning .................................................................................................................................................................. 28
Maintenance ............................................................................................................................................................ 28
Warranty ..................................................................................................................................................................... 29
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
4
IMPORTANT SAFETY INFORMATION
WARNING!
• THIS FIREPLACE IS HOT WHEN IN OPERATION AND CAN CAUSE SEVERE BURNS
• Do not operate fireplace before reading and understanding operating instructions. Failure to operate
fireplace according to operating instructions could cause fire or injury.
• Risk of burns. This fireplace is HOT when in operation and heating element is ON. Power to the fireplace
should be turned off and the fireplace allowed to cool before servicing. To disconnect power to the
fireplace, turn controls to off, then remove plug from outlet.
• Do not install damaged, incomplete, or substitute components.
• Young children should be carefully supervised when they are in same room with fireplace. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict access to the fireplace, install an
adjustable safety gate to keep toddlers, young children and other at risk individuals away from the fireplace
and hot surfaces.
• Clothing and other flammable material should not be placed on or near the fireplace.
• Due to high temperatures, the fireplace should be located out of traffic and away from furniture and
draperies.
• Ensure that you have incorporated adequate safety measures to protect infants/toddlers from touching hot
surfaces.
• It is imperative that the control compartments, circulating blower, and its passageway is kept clean.
• Under no circumstances should this fireplace be modified.
• Do not use the fireplace if any part has been under water.
• Do not operate the fireplace with the glass panel removed, cracked or broken.
• Keep the packaging material out of the reach of children. As with all plastic bags, these are not toys and
should be kept away from children and infants.
• Servicing should only be done while the fireplace is disconnected from the power outlet.
• Unplug fireplace if not being used for an extended period of time.
• Do not operate this fireplace with a damaged cord or plug after the fireplace malfunctions, has been
dropped, or damaged in any manner.
• Do not use outdoors.
• Never locate fireplace where it may fall into a bathtub or other water container.
• Do not run the cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord
away from traffic area and where it will not be tripped over.
• Connect to properly grounded outlets only.
• Do not insert foreign objects into any ventilation or exhaust opening as this may cause an electric shock,
fire, or damage to the fireplace.
• To prevent a possible fire, do not block the air intakes or exhaust in any manner. Do not use on soft
surfaces, like a carpet, where openings may be blocked.
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the fireplace.
Elevated temperatures on the wall or in the air above the fireplace can cause melting, discoloration or
damage to the decorations, a TV or other electronic components.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
5
General Information
CSA Approval Listing Information
This fireplace has been tested in accordance with the CSA Standards for fixed and location-dedicated electric room
appliances in the United States and Canada. If you need assistance during installation, please contact our technical
support department at 800-215-1990.
Note: This fireplace must be electrically wired and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition in the United States or the
Canadian Electric Code, CSA C22.1 in Canada.
Fireplace Specifications
Model Number 80036 80037 80038 80042
Description Sideline® Elite 50” Sideline® Elite 60” Sideline® Elite 72” Sideline® Elite 42”
Voltage 120v AC 120v AC 120v AC 120v AC
Watts Max 1500W Max 1500W Max 1500W Max 1500W
Amps 15 AMP 15 AMP 15 AMP 15 AMP
Fireplace Width 49 ¾” 59 ¾” 71 ¾” 41 ¾”
Fireplace Height 19 ¾” 19 ¾” 19 ¾” 19 ¾”
Fireplace Depth 5 ½” 5 ½” 5 ½” 5 ½”
Shipping Weight 63 lbs 73 lbs 90 lbs 48 lbs
Fireplace Weight 50 lbs 60 lbs 77 lbs 40 lbs
Serial Number Label
Each Touchstone Home Products Electric Fireplace contains a serial number label on the shipping box. Please
remove the shipping label and place the label on the back page of this manual for future reference.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
6
Dimensional Drawings
80036 – Sideline® Elite 50” Dimensions
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
7
80037 – Sideline® Elite 60” Dimensions
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
8
80038 – Sideline® Elite 72” Dimensions
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
9
80042 – Sideline® Elite 42” Dimensions
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
10
Unpacking Your Fireplace
Parts and Hardware
Tools Required
• Phillips screwdriver
• Stud finder
• Level
• Tape measure
• Electric drill
• 1/4” wood drill bit
What’s in the Box
Sideline Elite Fireplace
Drywall anchors
B – Wood Screws C – Drywall anchors
Remote Control
Metal Bracket
Wall Mount Bracket
(attached to back of fireplace)
Crystal Embers
(Large and Small)
Plastic Tray
Drift Wood Fire Logs
Unpacking and Setup
Unpacking Instructions
• Remove all parts and hardware from the carton and place them on a clean, soft, dry surface. Check the parts
list to make sure no parts are missing. If parts are missing, please contact technical support at 800-215-1990
for replacement parts.
NOTE: Dispose of plastic bag, as it may cause choking hazard with young children. Do not let children play
with plastic bag.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
11
Wiring
The Sideline® Elite series recessed fireplace can either be plugged into a grounded 3-prong outlet or hard wire
connection.
Testing the Fireplace Prior to Installation
• Before installing the fireplace, test the fireplace to make sure that it operates properly.
• Plug fireplace into approved outlet and power on fireplace. Once fireplace is tested, continue with
installation.
• If you have any problems, please contact technical support at 800-215-1990 opt 2.
3-prong Outlet Installation
• Only use this fireplace on a 120V AC, 15-Amp grounded circuit. Never overload the circuit. If this
fireplace trips the circuit breaker, unplug all other appliances on the same circuit before the next use. Avoid
plugging other appliances into the same circuit as this fireplace.
• Always check the fireplace plug and connections before each use.
• Never plug this fireplace into an outlet that is cracked or has any loose wires or connections. Plugging this
fireplace into a faulty outlet could result in the outlet overheating or catching fire.
• Make sure this plug fits securely into the outlet. Faulty wall outlet connections or loose plugs can cause the
outlet to overheat. If the outlet or faceplate is hot, discontinue use immediately and have a qualified
electrician inspect and/or replace the faulty outlet.
• The power cord supplied with the heater has three prongs: two flat blades (live and neutral) and one round
pin (ground). If a 3-slot receptacle is not available, an adapter MUST be used. The adapter MUST be
properly grounded to the outlet box (see figure below).
NOTE: Adapter NOT INCLUDED.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
12
Hard Wire Connection
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States
or the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada.
A. Remove the cover plate from the right side B. Remove the wire connectors from the power
bottom of the appliance by removing the three cord. Keep power cord, in case needed in future.
screws, as shown above. Save screws for
Installation of new cover plate.
C. Remove the power cable and wires from the cover plate. Thread your wiring through the hole in the cover
plate for connecting to the wires in the Sideline® Elite fireplace.
D. Using the wire connectors, connect the ground green wires (G), the common white wires (N)
together, and then the hot black wires (L) Refer to Figure 3 when complete.
E. Reinstall the cover plate using the three screws, as shown in Figure 1.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
13
Installation
WARNINGS
• Due to high temperatures, keep the fireplace out of high traffic locations.
• Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 36”
away from the front of the fireplace.
• Never install the fireplace where it may fall into a bathtub or other body of water.
• Wear safety gloves and safety glasses for protection during installation. Broken glass may cause injury or
harm.
• Prevent contact with loose insulation. Do not install the fireplace against a vapor barrier or exposed
insulation.
• Do not expose the fireplace to the elements (rain, etc).
Choosing Installation Location
Choosing Wall Location
• Measure wall location to ensure that fireplace will fit on desired wall location.
• Minimum clearances (measurements taken from front of glass panel):
Bottom of Fireplace to Floor: 6” Top of Fireplace: 8” to mantel
Sides of Fireplace: 0” Top of Fireplace: 8” to TV
Back of Fireplace: 0” Top of Fireplace: 8” to ceiling
• Select a location that is not prone to moisture and is located at least 36” away from combustible materials
such as curtains, drapes, furniture, bedding, or other combustible materials.
• See Safety Information on p. 4 for warnings about safe placement, safe installation, and proper use of this
product.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
14
Removing The Glass Panel
Remove the glass panel prior to installation. Please remove glass panel as per instructions below:
Instructions:
1. There are 2 screws in the top vent opening, one on the far left and one on the far right that secure the left and
right trim pieces in place. Remove both screws to remove the trim pieces.
2. After removing screws, tilt glass panel away from the fireplace. Lift the glass panel away from the fireplace to
remove the glass panel. Store the glass panel in a soft, dry place.
CAUTION: It is recommended that 2 people remove the glass panel to minimize chance of breakage.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
15
Recessed Installation
• Due to many different finish materials used on walls, it is highly recommended that you consult your local
builder before you install this fireplace in the wall.
• Select a location that is not prone to moisture and is located at least 36” away from combustible materials
such as curtains, drapes, furniture, bedding, or other combustible materials.
• In order to avoid the possibility of exposed insulation or vapor barrier coming in contact with the fireplace,
it is recommended that the walls of the fireplace enclosure be “finished” (ie. Sheetrock, drywall, etc) as you
would finish any other outside wall of your home. This will ensure that clearance to combustibles is
maintained within the wall cavity.
• Never install fireplace into load-bearing walls. When recessing fireplace in a wall, recess into non-load
bearing walls ONLY!
Instructions:
1. Choose a location in the wall to install fireplace.
2. Create opening in the wall that is no more than ¼” larger than metal firebox portion of fireplace.
Rough Opening Dimensions
Model A
(Width)
B
(Height)
C
(Depth)
80036 48 ¾” 18 ¼” 6”
80037 58 ¾” 18 ¼” 6”
80038 70 ¾” 18 ¼” 6”
80042 40 ¾” 18 ¼” 6”
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
16
Recessed Installation – cont.
3. Install the wall anchors (if wall opening is covered in sheetrock) according to the dimensions shown in the
drawing below:
a. Install wall anchors
b. Close-up for dimensions for wall anchor
installation
4. Remove the 2 brackets on each side of the flame area as shown below. Keep the screws and brackets handy, as
they will be re-installed later.
a. Remove screws holding brackets in place
b. Remove brackets
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
17
Recessed Installation – cont
5. With the help of a second person, insert the fireplace into the wall opening. Use the brackets removed in step 4
to secure the fireplace to the wall opening.
The fireplace is now ready to have the crystal embers and drift wood logs placed inside of the fireplace.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
18
Installing the Crystal Embers and Drift Wood Logs
Once the fireplace is installed in the wall, place crystal embers or fire log in the fireplace.
Installing the Crystal Embers
1. Place plastic tray strip in fireplace above the LED
lights as shown in the diagram to the right.
2. Carefully, place crystal embers on plastic strip as
illustrated in the picture to the right. Apply an even
layer from side to side.
Installing the Drift Wood Logs
1. Place drift wood log pieces in the fireplace as shown below.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
19
Reinstalling the Glass Panel
Once completed installing crystal embers or fire log, you are now ready to reinstall the glass panel.
1. Fit the bottom of the glass panel into the slot in the bottom of the firebox (A). Once in place, push the top of the
glass panel back toward the firebox (B).
2. Once the glass panel is in place, secure the glass panel to the firebox using the 2 screws removed in Remove the
Glass Panel section.
Your Sideline® Elite Series fireplace is now ready for use!
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
20
Wall Mounted Installation
• Due to many different finish materials used on walls, it is highly recommended that you consult your local
builder before you install this fireplace on the wall.
• Select a location that is not prone to moisture and is located at least 36” away from combustible materials
such as curtains, drapes, furniture, bedding, or other combustible materials.
Instructions
1. Select a location that is not prone to moisture and is located at least 36” away from combustible materials, such
as curtains, drapes, furniture, bedding, paper, etc.
2. With glass panel removed (see p.11 for instructions on removing glass panel), have two people hold the fireplace
against the wall to determine the final location.
3. Place the unit face down on a soft, non-abrasive surface. Remove the bracket from the back of the unit by
removing the screws holding the bracket to the back of the fireplace.
Wall Bracket Removal (1 bracket)
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
21
Wall Mounted Installation – cont.
4. Mark location of bracket on wall and then mount the bracket to the wall using the supplied screws and dry wall
anchors. The hooks in the bracket MUST be pointed away from the wall, upward, and level.
Note: Mount bracket to at least 2 studs. If 2 studs cannot be used, ensure that the supplied dry wall anchors are
used to affix the bracket to the wall and the bracket is adequately secured before moving to the next step.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
22
Wall Mounted Installation – cont.
5. With the wall mounting bracket installed, have 2 people lift the fireplace up and insert the 2 hooks on the bracket
into the back of the fireplace. The 2 hooks on the mounting bracket will line up with the 2 holes on the back of the
fireplace. Once aligned, the hooks will insert into the holes in the back of the fireplace and lock in the down
position.
Mounting bracket installed on wall Hang fireplace on mounting bracket hooks
6. Check the fireplace for stability, ensuring that the bracket will not pull free from the wall. Once satisfied, install
crystal embers/fire log and reinstall glass panel.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
23
Operating Fireplace
Once the fireplace has been plugged into a grounded outlet, the fireplace is now ready for operation. Ensure that
the house circuit breakers for the power supply are turned on.
Power
Plug the power cable into a 110v 15 amp grounded outlet. Make sure the outlet is in good condition and that the
plug is not loose. NEVER exceed the maximum amperage for the circuit. DO NOT plug other appliances into the
same circuit.
Methods of Operation
This electric fireplace can be operated by the CONTROL PANEL, located in the upper righthand corner of the
fireplace, or by the WIRELESS REMOTE CONTROL. The operation and functions of both methods are the same.
Control Panel
Wireless Remote Control
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
24
Method of Operation – cont.
Control Panel Functions
BUTTON FUNCTION ACTION & INDICATION
POWER
ON: Enables control panel functions and
remote control. Turns on flame effect.
OFF: Disables control panel functions
and remote control. Turns off flame
effect.
1. Press once. Indicator light turns on. Power
turns on. All functions enabled.
2. Press again. Flame effect turns off. Unit
goes to standby. All functions turn off.
FLAME
COLOR
Flame Color button: Changes the color
flame effect.
NOTE: Color effect stays on until power
button is turned off. Color flame effect
must be on for heater to turn on.
NOTE: The fireplace will remember the
last flame color used when the fireplace
is turned off. Unplugging the fireplace
will reset the color to the default color.
1. Press once to change the flame color.
2. Press again until desired setting is reached.
There is a total of 6 different flame color
combinations.
EMBER
LIGHTS
LED Ember Light button: Changes the
color of the embers below the
crystals/logs.
NOTE: Ember color effect stays on until
power button is turned off.
NOTE: The fireplace will remember the
last flame color used when the fireplace
is turned off. Unplugging the fireplace
will reset the color to the default color.
1. Press once to change the ember color.
2. Press again until desired setting is reached.
There is a total of 10 different ember color
combinations.
3. Auto-cycle function: When pressing with
the 11 th time, the LED ember light will do auto-
cycling (NOTE: It will take 15 seconds to
switch between colors.)
HEATER
Heater button: Turns heater on and off.
NOTE: The heater only works when the
flame effect is ON. If the flame effect is
OFF, the heater will not turn on.
NOTE: To prevent overheating, the
heater blows cool air for 10 seconds
before the heater turns on, and after it
turns off.
1. Press once. Indicator lights up.
Fan blows cool air for 10 seconds. Low
heater turns on and blows warm air.
2. Press again. Indicator lights up.
High heater turns on and blows hot air.
3. Press again. Heaters turn off.
The fan blows cool air for 10 seconds and
then turns off.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
25
Method of Operation – cont.
Wireless Remote Control Functions
BUTTON FUNCTION ACTION & INDICATION
POWER
ON: Enables control panel functions and remote
control. Turns on flame effect.
OFF: Disables control panel functions and
remote control. Turns off flame effect.
1. Press once. Indicator light turns on. Power turns on.
All functions enabled.
2. Press again. Flame effect turns off. Unit goes to
standby. All functions turn off.
TEMP
1. Press once: Touch panel indicator activates
2. Press again until desired temperature is reached. Digital display shows setting circles as below:
NOTE: Press and HOLD the button for 5 seconds to switch between °C and °F .
NOTE: If the room temperature is ABOVE the temperature listed on the display, the heater will not turn ON.
The room temperature needs to be below the temperature listed on the display for the heater to turn ON.
HEATER
Heater button: Turns heater on and off.
NOTE: The heater only works when the flame
effect is ON. If the flame effect is OFF, the
heater will not turn on.
NOTE: To prevent overheating, the heater
blows cool air for 10 seconds before the heater
turns on, and after it turns off.
1. Press once and the indicator lights up.
Fan blows cool air for 10 seconds. Low heater turns
on and blows warm air.
2. Press again and the indicator lights up.
High heater turns on and blows hot air.
3. Press again and the heater turns OFF.
The fan blows cool air for 10 seconds and then turns
off.
SPEED
Flame Speed button: Controls the speed of the
flame. There are 3 flame speed settings:
01 (slowest), 02 (Medium), 03 (fastest).
1. Press once to change the flame speed.
2. Press again until desired setting is reached. Display
shows the setting.
NOTE: The Default setting is 02 (medium speed)
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
26
Method of Operation – cont.
Wireless Remote Control Functions – cont.
BUTTON FUNCTION ACTION & INDICATION
TIMER
Timer button: Controls timer settings to turn
off fireplace at selected time.
Settings range from 1 hour to 8 hours.
1. Press once and the indicator lights up. Timer is
set to 1 hour.
2. Press again until desired setting is reached.
Indicator lights will show the timer setting.
FLAME
BRIGHTNESS
Flame button: Each press of the
flame button makes flame effect
dimmer and brighter.
NOTE: Flame effect stays on until power
button is turned off. Flame effect must be on for
heater to turn on.
1. Press once to change the flame brightness.
2. Press again until desired flame brightness
setting is reached.
FLAME
COLOR
Flame Color button: Changes the color flame
effect.
NOTE: Color effect stays on until power
button is turned off. Color flame effect must be
on for heater to turn on.
NOTE: The fireplace will remember the last
flame color used when the fireplace is turned
off. Unplugging the fireplace will reset the
color to the default color.
1. Press once to change the flame color.
2. Press again until desired setting is reached. There
is a total of 6 different flame color combinations.
EMBER
LIGHTS
LED Ember light button: Changes the
color of the embers below the crystals/logs.
NOTE: Ember color effect stays on until power
button is turned off.
NOTE: The fireplace will remember the last
flame color used when the fireplace is turned
off. Unplugging the fireplace will reset the
color to the default color.
1. Press once to change the ember color.
2. Press again until desired setting is reached. There
is a total of 10 different ember color combinations.
3. Auto-cycle function: When pressing with the 11 th
time, the LED ember light will do auto-cycling
(NOTE: It will take 15 seconds to switch between
colors.)
EMBER
BRIGHTNESS
LED Ember light brightness button: Makes
the LED ember lights on bottom effect change
brightness.
NOTE: LED Ember light brightness effect
stays on until power button is turned off.
1. Press once. LED ember light color changes
brightness.
2. Press again until desired setting is reached. In
total 5 levels.
From L1 - L2 - L3 - L4 - L5
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
27
Remote Control Operation
• This remote control uses one CR2025 battery (Included).
• Instructions for battery installation are located on the remote control battery compartment door.
• To improve operation of the remote control, aim the remote control at the front of the fireplace. DO NOT
PRESS the buttons too quickly. Give the unit time to respond to each command.
• NOTICE: NEVER dispose of batteries in fire. Failure to observe this precaution may result in an
explosion. Dispose of batteries at your local hazardous material processing center.
Changing Remote Battery
To replace the battery, do the following:
1. Pinch the clip on the battery door
2. Slide the battery drawer out of the remote to access the battery. When
installing the new battery, the positive (+) side of the battery faces UP.
Temperature Limiting Control
This heater is equipped with a Temperature Limiting Control. Should the heater reach an unsafe temperature, the
heater will automatically TURN OFF. To reset, please do the following:
1. Unplug the power cord from the outlet.
2. Turn ON/OFF switch on the CONTROL PANEL to OFF. Wait 5 minutes for fireplace to cool down.
3. Inspect the fireplace to make sure no vents are blocked or clogged with dust or lint. If they are, use a vacuum to
clean the vent areas.
4. With the POWER switch in the OFF position, plug the power cord back into the outlet.
5. If the problem continues, have your outlet and wiring inspected by a professional. If the outlet is OK, please
contact our customer support department at 800-215-1990.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
28
Care and Maintenance
Cleaning
• ALWAYS turn the heater OFF and unplug the power cord from the outlet before cleaning, performing
maintenance, or moving the fireplace. Failure to do so could result in electric shock, fire, or personal injury.
• NEVER immerse in water or spray with water. Doing so could result in electric shock, fire, or personal
injury.
Metal:
• Buff using a soft cloth, slightly dampened with citrus oil-based product.
• DO NOT use brass polish or household cleaners, as these products will damage the metal trim.
Glass:
• Use a good quality glass cleaner sprayed onto a cloth or towel. Dry thoroughly with a paper towel or lint-
free cloth.
• NEVER use abrasive cleansers, liquid sprays, or any cleaner that could scratch the surface.
Vents:
• Use a vacuum or duster to remove dust and dirt from the heater and vent areas.
Plastic:
• Wipe gently with a slightly damp cloth and a mild solution of dish soap and warm water.
• NEVER use abrasive cleansers, liquid sprays, or any cleaner that could scratch the surface.
Maintenance
• RISK OF ELECTRIC SHOCK! DO NOT OPEN any panels. No user-serviceable parts inside!
• ALWAYS turn the heater OFF and unplug the power cord from the outlet before cleaning, performing
maintenance, or moving the fireplace. Failure to do so could result in electric shock, fire, or personal injury.
Electrical and Moving Parts:
• The fan motors are lubricated at the factory and will not require lubrication.
• Electrical components are integrated in the fireplace and are not serviceable by the customer.
Storage:
• Store fireplace in a clean, dry place when not in use.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
29
Warranty
Touchstone Home Products®, Inc warrants our electric fireplaces to be free of defects in material and workmanship
for one year from date of purchase. Touchstone will repair or replace any fireplace or fireplace part that is deemed
defective or becomes defective during normal use within one year after the date of purchase.
Electrical components, such as fan motor, heater motor, control board, remote control, and control panel are
covered under warranty for one year from date of purchase. Touchstone Home Products® will provide replacement
parts free of charge during the first year of the warranty.
Replacement parts and fireplace units are covered under a 90-day warranty or the remainder of the original one year
manufacturer’s warranty from original date of purchase, whichever is greater.
Touchstone Home Products®, Inc does not warrant its products against damage caused by third parties.
Touchstone Home Products®, Inc does not cover damages caused by misuse, alterations, accident, lack of
maintenance, abuse or neglect. Parts installed from other manufacturers will void this warranty.
The warranty does not cover paint scratches, cosmetic blemishes, dents, corrosion, or other normal wear and tear
associated with the fireplace. Damage to fireplace or other components due to water, weather damage, long periods
of dampness, condensation, damaging chemicals or cleaners are not covered under warranty.
This warranty does not cover breakage of fireplace glass panel.
Touchstone Home Products® will not be responsible for installation, labor, or any other expenses related to the
reinstallation of a warranted part, and such expenses are not covered under warranty.
Extended warranty coverage for the fireplace is available by contacting Touchstone Home Products® directly at 1-
800-215-1990.
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
30
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
31
Sideline® Elite Series Electric Fireplace
www.touchstonehomeproducts.com 800.215.1990
rev. 20200113
32
Affix Serial Number Label Here
DESIGN & DEVELOPMENT D EPARTMENT
78-495 C ALLE T AMPICO
L A Q UINTA , C ALIFORNIA 92253
(760) 777 -7125 FAX (760) 777 -7011
Residential Plan Check Correction List Page 1 of 2
RESIDENTIAL PLAN CHECK CORRECTION LIST (OS)
DATE: MARCH 07, 2023
STATUS: FIRST REVIEW
PLAN CHECKED BY: DEISY MENDEZ/INTERWEST
TELEPHONE NUMBER: (760) 777-7002
ADDRESS: 77800 CALLE NOGALES
DESCRIPTION: NEW HOUSE
APPLICANT: NRC EQUITY FUND 1
PLAN CHECK #: BRES2022-1065
This submittal has been checked for compliance with the 2019 California Residential, Mechanical, Electrical, Plumbing,
Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to you for
correction:
1ST REVIEW PLAN SET MARKUP SUMMARY
1ST REVIEW CORRECTION LIST
DO NOT accept any resubmittal unless ALL of the
following items are included:
-RESPONSE LIST TO CORRECTION LISTS
-REVISED PLAN SET
- TRUSS CALCULATIONS
- DEBRIS MANAGEMENT PLAN (BURRTEC)
- GRANT DEED
- SCHOOL FEE RECEIPT
- CONTRACTOR INFORMATION
INSTRUCTIONS TO APPLICANT:
1) Provide a response to each comment on the following pages, noting specifically where the correction can be found.
Responses such as, “Sheet A-3,” or, “Handrails shall be per CBC Section 1003,” are not acceptable. Show or note
specifically how compliance with a code requirement is achieved. Responses such as, “Added note 16 on sheet A-3” are
appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise original Plans and/or Calculations as
necessary.
3) Each sheet of resubmitted Plans and/or Calculations shall include the preparer’s name and telephone number and shall
be electronically signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by
that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section
5536. Resubmittals will not be accepted with signatures missing.
Residential Plan Check Correction List Page 2 of 2
SECTION A - GENERAL
1) The City of La Quinta has elected to use Interwest Consulting for plan review of your project. In addition to the
comments provided by the City of La Quinta within this correction list please see the attached outside consultant
review comments. See Complete Review Comments Attached, for resubmittal please include a separate response
sheet for each set of review comments.
2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer’s name and telephone
number and electronic signature. If the preparer is a licensed architect or engineer, all documents prepared by that
licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536.
Resubmittals will not be accepted with signatures missing.
3) Provide Planning Division approval for this Project. Please contact Carlos Flores in the Planning Division directly at (760)
777-7069 with questions regarding the following comment(s):
a) GARAGE SETBACK SHALL BE 20'. CURRENTLY SHOWN AT 10'
4) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 65% of
the construction materials from landfill for the project. Contact the District Environmental Coordinator directly at (760)
674-1026 for free assistance with the preparation of this plan.
SECTION B – MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as
necessary and provide written response, noting where correction can be found.
2) Provide contractor information to complete building permit application form.
3) Provide proof of payment of school fees. While not required for resubmittal, this administrative item must be
addressed prior to issuance of building permit.
4) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation will be
performed when Plans are complete.
END CITY REVIEW CORRECTION LIST - CORRECTION LIST CONTINUED BY INTERWEST CONSULTING GROUP ATTACHED
As further information is provided and reviewed, additional corrections may be required.
1500 S. Haven Ave | Suite 220
Ontario, CA 91761
909.295-3142
January 11, 2023
CITY OF LA QUINTA - FIRST REVIEW
Permit No: BRES2022-1065
Interwest No.: LAQ22-0157
Non-Structural: 2.5-hours
Structural: 2-hours
City of La Quinta
Building Department
78-495 Calle Tampico
La Quinta, CA 92253
Plan Review: SFD w/garage
Address: 77800 Calle Nogales
Interwest Consulting Group has completed a first code compliance review of the following documents on behalf of
the City of La Quinta:
1. Drawings: Electronic copies of following:
a. CS through D1 dated 12/20/2022 by Cashcla Design & Associates.
b. E1.0 through P1.1 dated 12/20/2022 by Cashcla Design & Associates.
c. S-1 through S-3 dated 3/22/2021 by Cashcla Desig & Associates.
2. Structural Calculations: Electronic copy dated 12/12/2022 by Manuel A. Espino.
3. Energy Compliance Documentation: Electronic copy dated 11/21/2022 by SLO.
4. Geotechnical Investigation: Not provided.
The applicable provisions of the 2019 California Building Standards Code were used as the basis of this review.
Plan review comments follow on the attached list.
Please submit an itemized response letter and complete and revised documents with directly to city of La Quinta
Building and Safety Department.
Sincerely,
INTERWEST CONSULTING GROUP
Martha Diaz, P.E.
Plans Examiner
mdiaz@interwestgrp.com
909.719.0249
SFD w/garage City of La Quinta - First Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
1/11/23 Permit App: BRES2022-1065
Page 2 of 6
PROJECT DATA:
Occupancy Group: Area (sq. ft.):
R3 2,428
U 481
Total Area: 2,909
Building Height: 17’4”
Building Stories: 1
Type of Construction: VB
Occupant Load: <10
Sprinklered: Y
Valuation: TBD
Wildland Urban Interface
(WUI) Fire Area? TBD
Flood Zone: TBD
Risk Category: II
Site Class (seismic): D-default
Seismic Design Category: D
Special Wind Region: TBD
Snow Loads: N
GENERAL COMMENTS:
G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following
comments reference the 2019 California Building Standards Code as amended by the authority having
jurisdiction unless otherwise noted.
G2. Please respond in writing to each plan review comment by marking this comment list or creating a response
letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the
following should be included with each plan review response:
• Page / sheet number(s), detail / specification number(s), etc., and include all applicable code
section(s).
• Briefly explain in writing how the design is intended to comply with the applicable code sections.
• Please provide a narrative of revisions made outside the plan review comments.
Complete and clear responses will expedite the re-check of this project.
G3. Please be sure to include on the re-submittal the architect’s and /or engineer’s stamp, signature, date of
signature, and registration number on all sheets of plans depicting structural designed elements and cover
sheets of calculations. CBPC 5536.1 and 6735.
SFD w/garage City of La Quinta - First Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
1/11/23 Permit App: BRES2022-1065
Page 3 of 6
PLAN REVIEW COMMENTS:
BUILDING AND LIFE SAFETY:
A1. Drawing CS:
A.Please include “roof trusses” under “deferred approvals” list (separate permit not required). See
additional comments under structural section below regarding deferred trusses.
B.Please coordinate sheet index with sheets provided in drawings. S4 and HFX sheets are missing.
C.Please include in general information number of stories and overall building height (feet).
D.Please include in general information, “sprinklered: yes, nfpa 13D”.
E.Please include in general information if building is located in a fire zone (WUI), flood zone, or
special wind region. Coordinate with jurisdiction.
A2. Drawing A1:
A.Lots shall be graded to drain surface water away from foundation walls. The grade shall fall a
minimum of 6 inches within the first 10 feet. Show site drainage arrows away from perimeter
walls on plans. (R401.3 CRC)
B.Please provide roof eave dimensions on site plan. Projections beyond the exterior wall in fire-
sprinklered buildings shall have 1-hr. fire protection on the underside for projections greater
than or equal to 2ft up to 3ft. No protection is required when the projection is greater than 3ft
from a property wall. Provide complete details on the plans. (R302.1(2) CRC)
A3. Drawing A2:
A.Please show location of landings at exterior doors. Landing must measure 3’ in direction of
travel and be a min width as that of the door. The slope shall not exceed ½” units vertical in 12”
horizontal. Landing shall not be more than 1 ½” below the top of the door threshold. (R311.3)
B.Please note “tempered” glazing at front door and right side aluminum door.
C.Please coordinate window size at kitchen sink area with size noted on drawings (appears to be 6’
in width). Coordinate with energy calculations.
D.Please show garage slab slopes toward garage vehicle door.
E.Automatic garage door openers, if provided, shall be listed and labeled in accordance with
UL325. Note on plans. (R309.4 CRC)
SEE ADDED NOTES
SEE REVISED
REVISED INFORMATION
REVISED INFORMATION
NOT ANY OF THIS
SEE REVISIED SITE PLAN
SEE ROOF PLAN AND SITE PLAN 18 " OVERHANG
SEE SITE PLAN AND FLOOR PLAN
SEE REVISED ELEVATION AND FLOOR PLAN
SEE REVISED CALCS.
SEE REVISED INFORMATION
SEE ADDED NOTE
SFD w/garage City of La Quinta - First Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
1/11/23 Permit App: BRES2022-1065
Page 4 of 6
F.Please show additional attic access at garage and adjacent to bedrooms 1 and 2 (due to
separate attic spaces).
G.Smoke alarms are required immediately outside the vicinity of bedrooms. Please revise E1.0 to
show smoke alarms or combined smoke and carbon monoxide alarms. Clarify notes to indicate
both smoke and carbon monoxide alarms are required to be hardwired, interconnected, with
battery backup, and low battery signal.
H.Please coordinate elevations with front door shown on floor plans. If sidelight is included note
“tempered”.
A4. Drawing A3:
A.Please include at elevation notes for stucco: 7/8” over 2 layers of grade ‘D’ paper when applied
over plywood sheathing.
B.Please dimension a maximum 44” from finished floor to egress window openings.
C.Based on scale at elevations the clear opening height for egress windows appear to be less than
24” in height. The net clear opening dimensions required shall be obtained by the normal
operation of the emergency escape and rescue opening from the inside. Please verify minimum
requirements are met.
D.Please include in note ‘6’ if veneer is anchored or adhered. Include manufacturer and ESR#.
Coordinate weight (psf) with engineer of record.
E.Please indicate ceiling finishes at porches. If stucco coordinate with EOR and truss engineer.
F.Buildings shall have approved address identification that is legible and placed in a position that
is visible from the street or road fronting the property. Address identification characters shall
contrast with their background. Address numbers shall be Arabic numbers or alphabetical
letters. Letters shall not be spelled out. Each character shall be not less than 4 inches in height
with a stroke width of not less than ½ inch. Where access is by means of a private road and the
building address cannot be viewed from the public way, a monument, pole or other sign or
means shall be used to identify the structure. Address identification shall be maintained. Note
on plans. (R391.1 CRC)
A5. Drawing A4:
A.Please show on drawings the full height of gyp board from slab through attic at underside of
roof sheathing.
SEE PLANS
SEE ELECTRICAL PLANS
REVISED PLAN
SEE NOTE AT SECTION AND ROOF PLAN
SEE ELEVATIOPNS AND FLOOR PLAN
SEE REVISED WINDOWS
NOT VENEER ADDED
SEE PLANS
SEE ELEVATIONS
SEE REVISED SECTIONS
SFD w/garage City of La Quinta - First Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
1/11/23 Permit App: BRES2022-1065
Page 5 of 6
A5. Drawing A5:
A.Please show chimney location on roof plan. Provide flashing details at roof/chimney
intersection. Coordinate with framing plan. Details not provided for framing.
ENERGY COMPLIANCE:
Please incorporate energy compliance forms into drawings.
Electrical Compliance:
No comments 1/11/2023 MD
Mechanical Compliance:
EM1. Drawing M1.0:
A.Please show location of IAQ fan and location of FAU’s on drawings.
Envelope Compliance:
EC1. Drawing A2:
A.Please include U and SHGC factors per compliance forms for all glazing at floor plan.
EC2. Drawing A4:
A.Please show “radiant barrier” at sections.
B.Please include in section notes R-4.2 sheathing is required at exterior walls.
C.Please include “R-21” at note ‘20’ at interior garage wall.
EC3. Drawing A5:
A.Please note “cool roof” at proposed roofing material.
B.Please coordinate roofing material type and roof slope in energy documents with drawings. If roof
tile is proposed, please revise roof plan. Note manufacturer, model, classification (A or B),
underlayment, and ESR#.
DECORATIVE ELEMENT IT'S ELECTRICAL FIRE FIXTURE
SEE ADDED INFORMATION
SEE FLOOR PLAN
SEE REVISED INFORMATION
SEE REVISED NOT FLOOR PLAN AND SECTION
SEE PLAN REVISED INFO AT SECTION AND FLOOR PLAN
SEE ROOF PLAN
SEE ROOF PLAN INFO.
SFD w/garage City of La Quinta - First Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
1/11/23 Permit App: BRES2022-1065
Page 6 of 6
CalGREEN:
CG1. Drawing A2:
A.Heat n Glo model specified on drawings may be discontinued (unable to find on manufacturer
website). Please provide model and UL listing for a gas fire placed that is direct-vent and sealed
combustion (fixed glass front) per CalGreen requirements. Include specifications on drawings.
Revise keynote ‘50’ as appropriate.
CG2. Drawing E1.0:
A.Please revise legend for bathroom exhaust fan to include: to be energy star rated and equipped
with humidistat.
STRUCTURAL:
S1. Drawing S-1:
A.A geotechnical report is required for all new residential projects unless an exemption is provided in
writing from the Building Department.
a.Reference soils report on drawings and provide approval letter from soils engineer or
stamp/signature on foundation plan and foundation details.
S2. Drawing S-2:
A.Roof trusses may not be deferred without written permission from the Building Department via a
completed deferred truss submittal form. Unless a completed form is provided, truss drawings and
calculations must be provided no later than the second submittal.
a.Please note on plan truss package shall be reviewed by the engineer of record and
submitted to the city for review.
B.Please provide a complete nailing schedule on framing plan per chapter 23, 2019 CBC.
Please contact the listed reviewers between 9:00 A.M. and 4:00 P.M., M-F, with any questions.
[END]
REVISED FIREPLACE ELECTRICAL FIXTURE
SEE EI.I INFORMATION
SEE PLAN S4
SEE INFO
DESIGN & DEVELOPMENT D EPARTMENT
78-495 C ALLE T AMPICO
L A Q UINTA , C ALIFORNIA 92253
(760) 777 -7125 FAX (760) 777 -7011
Residential Plan Check Correction List Page 1 of 2
RESIDENTIAL PLAN CHECK CORRECTION LIST (OS)
DATE: APRIL 07, 2023
STATUS: SECOND REVIEW
PLAN CHECKED BY: DEISY MENDEZ/INTERWEST
TELEPHONE NUMBER: (760) 777-7002
ADDRESS: 77800 CALLE NOGALES
DESCRIPTION: NEW HOUSE
APPLICANT: NRC EQUITY FUND 1
PLAN CHECK #: BRES2022-1065
This submittal has been checked for compliance with the 2019 California Residential, Mechanical, Electrical, Plumbing,
Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to you for
correction:
2ND REVIEW PLAN SET MARKUP SUMMARY
2ND REVIEW CORRECTION LIST
DO NOT accept any resubmittal unless ALL of the
following items are included:
-RESPONSE LIST TO CORRECTION LISTS
-REVISED PLAN SET
- TRUSS CALCULATIONS
- DEBRIS MANAGEMENT PLAN (BURRTEC)
- CONTRACTOR INFORMATION
INSTRUCTIONS TO APPLICANT:
1) Provide a response to each comment on the following pages, noting specifically where the correction can be found.
Responses such as, “Sheet A-3,” or, “Handrails shall be per CBC Section 1003,” are not acceptable. Show or note
specifically how compliance with a code requirement is achieved. Responses such as, “Added note 16 on sheet A-3” are
appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise original Plans and/or Calculations as
necessary.
3) Each sheet of resubmitted Plans and/or Calculations shall include the preparer’s name and telephone number and shall
be electronically signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by
that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section
5536. Resubmittals will not be accepted with signatures missing.
Residential Plan Check Correction List Page 2 of 2
SECTION A - GENERAL
1) The City of La Quinta has elected to use Interwest Consulting for plan review of your project. In addition to the
comments provided by the City of La Quinta within this correction list please see the attached outside consultant
review comments. See Complete Review Comments Attached, for resubmittal please include a separate response
sheet for each set of review comments.
2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer’s name and telephone
number and electronic signature. If the preparer is a licensed architect or engineer, all documents prepared by that
licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536.
Resubmittals will not be accepted with signatures missing.
3) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 65% of
the construction materials from landfill for the project. Contact the District Environmental Coordinator directly at (760)
674-1026 for free assistance with the preparation of this plan.
SECTION B – MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as
necessary and provide written response, noting where correction can be found.
2) Provide contractor information to complete building permit application form.
3) Provide proof of payment of school fees. While not required for resubmittal, this administrative item must be
addressed prior to issuance of building permit.
4) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation will be
performed when Plans are complete.
END CITY REVIEW CORRECTION LIST - CORRECTION LIST CONTINUED BY INTERWEST CONSULTING GROUP ATTACHED
As further information is provided and reviewed, additional corrections may be required.
1500 S. Haven Ave | Suite 220
Ontario, CA 91761
909.295-3142
March 29, 2023
CITY OF LA QUINTA - SECOND REVIEW
Permit No: BRES2022-1065
Interwest No.: LAQ22-0157
Non-Structural: 1.50-hours
Structural: 0.50-hours
City of La Quinta
Building Department
78-495 Calle Tampico
La Quinta, CA 92253
Plan Review: SFD w/garage
Address: 77800 Calle Nogales
Interwest Consulting Group has completed a second code compliance review of the following documents on behalf
of the City of La Quinta:
1.Drawings: Electronic copies of following:
a.CS through D1 dated 3/22/2023 by Cashcla Design & Associates.
b.E1.0 through P1.1 dated 3/22/2023 by Cashcla Design & Associates.
c.S-1 through S-3 dated 3/22/2021 by Cashcla Desig & Associates.
2.Structural Calculations: Electronic copy dated 12/12/2022 by Manuel A. Espino.
3.Energy Compliance Documentation: Electronic copy dated 3/20/2023 by SLO.
4.Geotechnical Investigation: Not provided.
The applicable provisions of the 2019 California Building Standards Code were used as the basis of this review.
Plan review comments follow on the attached list.
Please submit an itemized response letter and complete and revised documents with directly to city of La Quinta
Building and Safety Department.
Sincerely,
INTERWEST CONSULTING GROUP
Martha Diaz, P.E.
Plans Examiner
mdiaz@interwestgrp.com
909.719.0249
SFD w/garage City of La Quinta - Second Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
3/29/23 Permit App: BRES2022-1065
Page 2 of 5
PROJECT DATA:
Occupancy Group: Area (sq. ft.):
R3 2,428
U 481
Total Area: 2,909
Building Height: 17’4”
Building Stories: 1
Type of Construction: VB
Occupant Load: <10
Sprinklered: Y
Valuation: TBD
Wildland Urban Interface
(WUI) Fire Area? TBD
Flood Zone: TBD
Risk Category: II
Site Class (seismic): D-default
Seismic Design Category: D
Special Wind Region: TBD
Snow Loads: N
GENERAL COMMENTS:
G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following
comments reference the 2019 California Building Standards Code as amended by the authority having
jurisdiction unless otherwise noted.
G2. Please respond in writing to each plan review comment by marking this comment list or creating a response
letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the
following should be included with each plan review response:
•Page / sheet number(s), detail / specification number(s), etc., and include all applicable code
section(s).
•Briefly explain in writing how the design is intended to comply with the applicable code sections.
•Please provide a narrative of revisions made outside the plan review comments.
Complete and clear responses will expedite the re-check of this project.
G3. Please be sure to include on the re-submittal the architect’s and /or engineer’s stamp, signature, date of
signature, and registration number on all sheets of plans depicting structural designed elements and cover
sheets of calculations. CBPC 5536.1 and 6735.
SFD w/garage City of La Quinta - Second Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
3/29/23 Permit App: BRES2022-1065
Page 3 of 5
PLAN REVIEW COMMENTS:
The revised permit documents have been reviewed. The following comments are numbered per the original list
and require further response and/or revision. The format includes a restatement of the original comment
followed by new or clarified recheck comments in bold italic print and identified as PC2.
BUILDING AND LIFE SAFETY:
PC2: [Jim Northcutt; jnorthcutt@interwestgrp.com; 559.271.6933
A1. Drawing CS:
A.Please include “roof trusses” under “deferred approvals” list (separate permit not required). See
additional comments under structural section below regarding deferred trusses.
PC2: Plan check remains: Please provide approval from the City and submit approval letter on
next submittal or provide truss calculations.
E.Please include in general information if building is located in a fire zone (WUI), flood zone, or
special wind region. Coordinate with jurisdiction.
A3. Drawing A2:
A.Please show location of landings at exterior doors. Landing must measure 3’ in direction of
travel and be a min width as that of the door. The slope shall not exceed ½” units vertical in 12”
horizontal. Landing shall not be more than 1 ½” below the top of the door threshold. (R311.3)
PC2: Plan check remains: Add Landing shall not be more than 1 ½” below the top of the door
threshold.
A4. Drawing A3:
D.Please include in note ‘6’ if veneer is anchored or adhered. Include manufacturer and ESR#.
Coordinate weight (psf) with engineer of record.
PC2: Plan check remains: Please provide manufacturer's name and ESR# on note 6.
ENERGY COMPLIANCE:
PC2: [Jim Northcutt; jnorthcutt@interwestgrp.com; 559.271.6933
PC2-Additional Correction: Please clarify why the square footagte on the CF-1R forms is less (2373 sf) that
what is shown on the plans (2428 sf)
Electrical Compliance:
No comments 1/11/2023 MD
SEE ATTACHED TRUSSES
SEE CONC. AND SLOPE AT SITE PLAN AND FLOOR PLAN ALSO I ADD A NOTE ON
BOTH PLANS SEE GRADING PLANS FOR REF ONLY)
DELETED , STUCCO FINISH
SEE REVISED REPORT
SFD w/garage City of La Quinta - Second Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
3/29/23 Permit App: BRES2022-1065
Page 4 of 5
Mechanical Compliance:
No further comments. JFN 3/29/2023
Envelope Compliance:
EC2. Drawing A4:
B.Please include in section notes R-4.2 sheathing is required at exterior walls.
PC2: Plan check remains: On note 18 add the R4.2 rating of the EPS and include the manufacturer's
name and ESR report number.
EC3. Drawing A5:
A.Please note “cool roof” at proposed roofing material.
PC2: Plan check remains: Cool roof is not called out on the plans. Please revise the plans to specify
a roofing material rated by the Cool Roof Rating Council (CRRC) with a solar reflectance of at least
0.37, and roof emittance of at least 0.92 as modeled in the CF1R. Please include the CRRC product
ID on the plans.
B.Please coordinate roofing material type and roof slope in energy documents with drawings. If roof
tile is proposed, please revise roof plan. Note manufacturer, model, classification (A or B),
underlayment, and ESR#.
PC2: Plan check remains for roof slope. Roof notes indicates slope to be 4:12, however this is a flat
roof as shown on the CF-1R forms. Please clarify.
CalGREEN:
PC2: [Jim Northcutt; jnorthcutt@interwestgrp.com; 559.271.6933
CG1. Drawing A2:
A.Heat n Glo model specified on drawings may be discontinued (unable to find on manufacturer
website). Please provide model and UL listing for a gas fire placed that is direct-vent and sealed
combustion (fixed glass front) per CalGreen requirements. Include specifications on drawings.
Revise keynote ‘50’ as appropriate.
PC2: New electric fireplace information generated the following corrections:
Please add the electric fireplace to the CF-1R forms.
SEE REVISED SECTION
SEE ROOF PLAN SECTIONS AND ROOF PLAN
SEE REVISED REPORT
DECORATIVE FIREPLACE SEE FLOR PLAN NOTE (WALL FIXTURE)
SFD w/garage City of La Quinta - Second Review
77800 Calle Nogales Interwest Project No. LAQ22-0157
3/29/23 Permit App: BRES2022-1065
Page 5 of 5
STRUCTURAL:
PC2: [Jim Northcutt; jnorthcutt@interwestgrp.com; 559.271.6933
S1. Drawing S-1:
A.A geotechnical report is required for all new residential projects unless an exemption is provided in
writing from the Building Department.
PC2: Plan check remains: Please provide geotechnical report or provide in writing exemption
from the building department.
B.
a.Reference soils report on drawings and provide approval letter from soils engineer or
stamp/signature on foundation plan and foundation details.
b.PC2: Plan check remains: Reference soils report on drawings and provide approval letter
from soils engineer or stamp/signature on foundation plan and foundation details.
S2. Drawing S-2:
A.Roof trusses may not be deferred without written permission from the Building Department via a
completed deferred truss submittal form. Unless a completed form is provided, truss drawings and
calculations must be provided no later than the second submittal.
PC2: Plan check remains: No response from this requirement. Roof trusses may not be deferred
without written permission from the Building Department via a completed deferred truss
submittal form. Unless a completed form is provided, truss drawings and calculations must be
provided no later than the second submittal.
a.Please note on plan truss package shall be reviewed by the engineer of record and submitted
to the city for review.
PC2: Plan check remains: Provide truss package review by EOR.
Please contact the listed reviewers between 9:00 A.M. and 4:00 P.M., M-F, with any questions.
[END]
N/A AT THIS LOCATION
N/A AT THIS LOCATION
SEE ATTACHED STAMPED TRUSSES
SEE TRUSSES CALCS. AND TRUSSES LAYOUT
BRES2022-1065 (77800 CALLS NOGALES LA OUINTA, CA 92253)
Electric subpane relocation at back wall of the w.cl.
"Ms. Molina, thank you for reaching out to Carlos and I regarding an issue with an inspection at 77800
Calle Nogales. I am providing some background information which was a catalyist requiring a revision letter.
At issue was a subpane) placed in a closets in one of the bedrooms. The building inspector Mr. Tuevill
stated placement of a subpane) in that location was not allowed. Any appurtenants part and parcel of a
clothes closet were removed, in essence it became an area void of anything. Upon re —inspection Mr. Tuevil
stated this was still unacceptable, that being said, arrangements were made to move this subpane) and
facilitate Mr. TueviWs demands.
Subsequently the Electrical contractor (Pacific Custom Electric) is going to move the subpane) to a location
on an exterior wall which will be identified by drawing. Mr. Sanchez is preparing the necessary revisions
displaying the location and calculations.
believe Mr. Sanchez will have the revisions prepared today or tomorrow. Again, thank you for reaching out
in an attempt to resolve this situation. The home is ready to be moved into upon compliance."
Gary Spackman
OFFICE OF THE FIRE MARSHAL – LA QUINTA
78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074
• www.rvcfire.org
March 1, 2023
NRC Equity Fund 1
74045 Rutledge Way
Palm Desert, CA 92260
Re: Residential Fire Access & Water Plan Review – NOGALES LOT 11
BRES2022-1065 / 77800 CALLE NOGALES, LA QUINTA, CA 92253
The plans you submitted for the above referenced project have been reviewed by Riverside County Fire
Department - Office of the Fire Marshal personnel and are approved with the following conditions.
1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to
their background shall be displayed on the structure and viewable from the roadway or posted at the
driveway entrance and maintained visible.
2) The proposed structure requires a fire flow of 500 gallons per minute from a single hydrant located
within 600-feet of all exterior portions of the structure. (CFC 507.5.1 & APPENDIX B)
3) Dwelling Units shall maintain a minimum 3-feet clear width Egress Court from emergency escape
windows and doors of sleeping rooms and shall deposit to the front of the property or public way.
(Ref. CBC 1028.4 / CRC R311.1)
4) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed
Contractor (C-16) shall submit plans and details for review and approval prior to system installation
and Rough Inspections.
The Fire Department approved plans and conditions letter must be at the job site.
Applicant shall be responsible to contact the Fire Department to schedule inspections. Requests for
inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131.
All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal
staff at (760)777-7074.
Kohl Hetrick - Fire Safety Specialist
4/21/23, 12:41 PM CRRC Roof Directory
https://coolroofs.org/directory/roof?keywords=0918-0046 1/1
Rated Roof Products
1 result
CRRC PROD ID.MANUFACTURER BRAND AND MODEL INITIAL
SOLAR REFLECTANCE
3 YEAR INITIAL
THERMAL EMITTANCE
3 YEAR INITIAL
SRI
3 YEAR
0918-0046 EAGLE Roo ng Products Slate Range, Charcoal Range, Lehigh Blend MWM
7699 Midweight Malibu,Bel Air 4697, Capistrano
3697, Golden Eagle 1699, Malibu 2697, lt-wt Bel
Air 297, lt-wt Capistrano 597, lt-wt Golden Eagle
199, lt-wt Malibu 497, Estate SHE 8704, Es
0.15 0.17 0.94 0.92 15 16
CERTIFICATE OF OCCUPANCY
DESIGN AND DEVELOPMENT DEPARTMENT
This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the
California Residential Code, certifying that, at the time of issuance, this structure was in
compliance with the provisions of the Building Code and the various ordinances of the City
regulating building construction and/or use.
BUILDING ADDRESS: 77800 CALLE NOGALES
Use Classification: Building Residential Permit No.: BRES2022-1065
Occupancy Group: R-3: 1 & 2 Family
Dwellings
Type of Construction: V-B Land Use Zone:
Code Edition: 2019 Sprinkler Installed: YES Sprinkler Required: YES
By: Taylor Tuvell Owner of Building: NRC EQUITY FUND 1
Date: 1/7/2025 12:00:00AM Address: 736 S, CENTER ST
Building Official: AJ ORTEGA City, ST, ZIP: RENO NEVADA, NV 89501
POST IN A CONSPICUOUS PLACE