Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FA2024-0005
BUILDING PERMIT DESIGN & DEVELOPMENT PHONE (760) 777-7125 DEPARTMENT "fra WWW.LAQUINTACA.GOV 78-495 CALLE TAMPICO APPLIED DATE: 05/02/2024 LA QUINTA, CALIFORNIA 92253 ta ISSUED DATE: CALIFORNIA Permit Type: Fire Alarm/Monitoring System Owner: Permit Number: FA2024-0005 Applicant: Sergio Jauregui Property Address: 50777 SANTA ROSA PLAZA 15531 Container Lane, Huntington Beach, CA APN: 770020031 92649 Legal Description Parcel 6 PM 200/84 PM 29909 Contractor: Sergio Jauregui / 612153 Property Zoning: GC, VC, 6 15531 Container Lane, Huntington Beach, CA 92649 Valuation: $0.00 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.htm1. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 7/2/26 10:04 am Page 1 of 4 BUILDING PERMIT Permit Type: Fire Alarm/Monitoring System Permit Number: FA2024-0005 Property Address: 50777 SANTA ROSA PLAZA nary notice from Printed: 7/2/26 10:04 am Page 2 of 4 BUILDING PERMIT Permit Type: Fire Alarm/Monitoring System Permit Number: FA2024-0005 Property Address: 50777 SANTA ROSA PLAZA New cellular commercial fire communicator connected to a previously approved fire alarm system. Building/Unit B: Office, Professional, Calculated Occupancy N/A Fire Alarm System - Advanced Protection Occupancy R-1: Transient Residential Load Monitoring Company Industries Inc. Classification(s) Name Monitoring Company 25341 Commercentre Dr., Monitoring Company (800) 662-1711 Supervising Station Remote Supervising Address Lake Forest, CA 92630 Phone Number Type Station UL CERTIFICATE # (if Zoning GC, VC General Plan VC, OS-R applicable): City Limits Within La Quinta Limits Subdivision Name PM 29909 Lot Number 6 Lot Size 39856.7 Centerlines 97296 Legal Description Parcel 6 PM 200/84 PM 29909 Lint • Type Group Sq Ft Value 71nvoice No. Fee Fee Amount Amount Paid 06546 Digital Archiving and Records Management Fee - OTC $12.00 $12.00 Credit Card Convenience Fee $11.95 $11.95 Technology Enhancement Fee $8.00 $8.00 Fire - Alarm -Monitoring and Tenant Improvements $458.00 $458.00 Total for Invoice INV-00006546 $489.95 $489.95 Grand Total for Permit $489.95 $489.95 Workflow Step / Action Name Action Type Start Date End Date Review v.1 05/03/2024 0:00 05/10/2024 13:52 Fire Review v.1 Receive Submittal 05/03/2024 0:00 05/10/2024 13:52 Inspections v.1 07/01/2024 0:00 07/02/2024 18:52 ----------------------------------------------------------------------------------------------------------------------------------------- Fire Alarm Rough Wire v.1 Inspection 07/01/2024 0:00 07/02/2024 18:51 Fire Alarm - Function Test v.1 Inspection 07/01/2024 7:52 07/02/2024 18:51 Fire Alarm Final v.1 Inspection 07/02/2024 18:52 07/02/2024 18:52 Printed: 7/2/26 10:04 am Page 3 of 4 BUILDING PERMIT Permit Type: Fire Alarm/Monitoring System Permit Number: FA2024-0005 Property Address: 50777 SANTA ROSA PLAZA Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 7/2/26 10:04 am Page 4 of 4 O E s oa0ae w`q Qoa 7A ' o w=8 O -w s. wmeLL H�°' a`o" - II ° vi ,3� =s " rc -Z 8z o` z a m <w�= ¢ g LL 0861 S b 8 4444444444444WmUUA5 3 aLL�= & u S� "R2-9 J z i Wo o '- wsLo o w o ANN MH tl LL ? a o o @ w�� Vyyy " =go s#o wwop°" v 9- trg j " a _ Noe#F 2� y a H ° 35 t o h u, gmm o �d :€��W:m 6 p `o o ^visa E p oBp - a ° 2 a €a ° fro 8 spa 'CHE 819 �5 B g a on8�8€� o84m` o H int. i a - _ a � e a uw Eb w Wy a g �� eg o 3 Q z € aecF w Rgw g ads"nH O §ew `ss>ge wo a -_ s.aw ;" = a aae _ ., 3Sw ?€ §oawrW wJ a:q;o :dE G< at w w C a k aRg §a s o a a€x oa ao § ^ a 6 ° a� hNN g 3 6' gym .$ y aw` 3a WN P "€a J a na ew ;^€ ya � wF? a.m`a s & Sew LL, � e xs a a# H M; 3 wa U H! §` §E s ¢aE a°� s a§ s °g;o § =Bga € y °Ratio` s we r:w�€ 5sy o§ o - _.° asp_ B, xg G m �� Fm n€ w�a.: E<ep g&o s w��.< o= oga _ �= as y§ €s€ wsEe , ti c N = = s# $� wi w�a ga m<sa o i a=a a§'s a " e` gas �g w°"s 4a g_ g g $esm a� s o a° _€ szlg�sa bweaLL ? o am §€§ _€ w€a �s a tie' a� a< _° �`_:ME _ „L gg ps z d s NaxaY_ s ` o m g� C,° ° ° ° € 5 HE °� a�•Fy :w'� 5 � �o� _ " sa anew, aa�a w= � �__ = saw a = $a of pn ca a€sa# z $ nG , ag` € _=mwo m pa e ioao€i R .c°a m a g € o a ow a 8 o va°sue W€§ p nsw .F em a§ sa - ` 'II Ns $ a $w�.s a ° z" zos as#ea €?gym a aoo° 3 =a ��c •€ °_ U %gg°.- a= s 3"w x e41 " p " m €a € u ^a x a _ "_= s w g aa= _w « €�e� €w=a" .s Z w �aogwae'aa"Em€p` w # aE' asg g�= app� sw a c " a spaw€m_ _asa § a <# a as§po area" aHz - m��.� ee;= �€o€€� m s s g e s o b m g e a a a a a a a a - - - - - - - <tY = _ <S <S = <S 0 ~ �° o m Um 3z u0 u� x� xp x x K� x� u� u� x0 x0 w 8. 0 0 ° a, ° ° o S g� ° ° °> 8s 8. i fn wx x om P� V w= wI w �h h x H g� H wh w ° Z _ a 5 - - - - - - - - w� g w� m } 10 1 Z ao �rc o w 'o o'o ww w� zy� u�R cwi s u o sE fE om W. -o fl ° <pLIE� tiw os s8 <p < �� w �w < aw <w = <w <w o ZW wz °8 < m 3LL �q p rc LLi LLi � a� a� am y 3m=LLy=LL"za" 3N 36 w w w w w w w IIIIIIIIIIIIIIIIIIIIIIIII I1101111111101f llllllllll 11111111111111 � 1111111111 . IIIIIIIIIC011111111111111 1111111111011111111111111 1111111011111111111111111 . IIIIIIIICCIIIIIIIIIIIIIII ' - CDOCIIIDCC110110011110111 ...:' Io011CI00011011CC11110111 1111111111111111111111111 CDOCIIICCC01011CC11111111 . . o0oCI1100001011.0011111111 1111111111110111111111111 .° IIIIIIIIIIIIIIIIIICIo00oC . IIIIICIIIIIIl01 IICI'11111 o0oCI11o0001016oC11 J1111 '-'-oOOCICICCC01oCVCCCCOOCOC 1p1111111111111111p1111111p1 . , 11111111111111IIIC1I000C . IIIIICI1111'IC IIC1101111 . o0oCI11o000 01 CC11111111 w s � ���; , � x inn, ■. 1 n Tf 1f1i �I Fy : � Fir o �` 4 �1 � ��_ I ■ ■ � � Q a _ �Illllilllllllil � = _ L H ii Ing 4 .II MLIJ 541 . II I����I:II�III�I ■ �1 � - � �:: rimy \1�IIIIIII` II � �oo� "IIIIIII >L _ �II� I ;. ► i�IIII�� F R—a F, Q IF,A IEi I;d - ��.... ...... .. .... .... .... .. ..,,ems. CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT Qa�&a BILL WEISER . THIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA—CALIFORNIA- 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org May 10, 2024 Sergio Jauregui, Pyro Comm Systems Incorporated Re: Fire Alarm System — Embassy Suites Cellular Communicator FA2024-0005 / 50777 Santa Rosa Plaza The plan for the above referenced project was reviewed and approved by the Riverside County Fire Department with the following conditions: 1. The Inspector shall witness a function test including at least one signal transmission. 2. Provide an updated Record of Completion with the means of transmission noted. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance by sending an email to FireBusinessMail(cr�,laquintaca. gov. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox — Supervising Fire Marshal RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD a�Cv a�ccCv THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. — CALIFORNIA — INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 50777 Santa Rosa Plaza PERMIT#: FA2024-0005 AT ED: 5/10/24 DESCRIPTION: Fire Alarm CONTRACTOR: Pyro Comm Systems Inc. HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final EF Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final EF SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final EF FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections email: FireBusinessMail(�i_)laquintaca.gov B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 Pyro-Comm Systems, Inc. 15215 ALTON PARKWAY SUITE #200 • IRVINE, CA 92618 (714) 902-8000 • FAX (714) 902-8001 Embassy Suite — Cellular Communicator 50777 Santa Rosa Plz. La Quinta, CA 92253 Fire Alarm System Submittal PCSI Job# 5421042 FIRE ALARM SYSTEM MFG. MODEL# DESCRIPTION CSFM# [CONTROL PANELS] NOTIFIER NFS-3030 (Existing) Fire Alarm Control Panel 7165-0028:0224 [DIALER PANELS] HONEYWELL HON-CGW-MBB Cellular Alarm Communicator 7300-1637:0504 C-10 612153 NORTHERN CA REGIONAL OFFICE • 10966 BIGGE STREET • SAN LEANDRO, CA 94577 SAN DIEGO REGIONAL OFFICE • 5115 AVENIDA ENCINAS, SUITE G • CARLSBAD, CA 92008 (510) 632-1208 (760) 930-6014 DN-7112:H • A-14 NFS-320(E) Intelligent Addressable Fire Alarm System General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to pro- tect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones/points, order separately; see DN-60085). The Fire Watch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless called out with a version -specific "R", "C" or "E" at the end of the part number, `NFS-320" refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E. Features • Certified for seismic applications when used with the appro- priate seismic mounting kit. • Approved for Marine applications when used with listed compatible equipment (see DN-60688). • One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. • Up to 159 detectors (any mix of ion, photo, thermal, or multi - sensor) and 159 modules (Addressable pull stations, nor- mally open contact devices, two -wire smoke, notification, or relay). 318 devices maximum. • Standard 80-character display. • Network options: — High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYXWorks, NFS-3030, NFS-640, and NCA). — Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYX - Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC is used in network paging. • 6.0 A power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 318-point DACT. • 80-character remote annunciators (up to 32). • EIA-485 annunciators, including custom graphics. • Printer interface (80-column and 40-column printers). • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm -only file. �J NOT IFIER° by Honeywell NFS-320 • Alarm Verification selection per point, with tally. • Presignal/Positive Alarm Sequence (PAS). • Silence inhibit and Auto Silence timer options. • NAC coding functions: — March time. — Temporal. — California two -stage coding. — Canadian two -stage. — Strobe synchronization. • Field -programmable on panel or on PC, with VeriFire® Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 — 200 AH batteries. • Non -alarm points for lower priority functions. • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Extensive, built-in transient protection. • Powerful Boolean logic equations. FLASHSCANO INTELLIGENT FEATURES • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high -precision protocol (U.S. Patent 5,539,389). • Manual sensitivity adjustment — nine levels. • Pre -alarm ONYX intelligent sensing — nine levels. • Day/Night automatic sensitivity adjustment. • Sensitivity windows: — Ion — 0.5 to 2.51/o/foot obscuration. — Photo — 0.5 to 2.35%/foot obscuration. — Laser (VIEW®) — 0.02 to 2.0%/foot obscuration. — Acclimate® PIusTM — 0.5 to 4.0%/foot obscuration. — IntelliQuad — 1.0 to 4.0%/foot obscuration. — IntelliQuad TM PLUS — 1.0 to 4.0%/foot obscuration • Drift compensation (U.S. Patent 5,764,142). DN-7112:H • 08/09/2012 — Page 1 of 6 • Degraded mode — in the unlikely event that the NFS-320's primary microprocessor fails, FlashScan detectors revert to degraded operation and can activate the control panel's NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. • Multi -detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). • Automatic detector sensitivity testing (NFPA-72 compliant). • Maintenance alert (two levels). • Self -optimizing pre -alarm. FSL-751 VIEW (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non -smoke signals (U.S. Patent 5,831,524). • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATED PLUSTm LOW -PROFILE INTELLIGENT MULTI -SENSOR • Detector automatically adjusts sensitivity levels without oper- ator intervention or programming. Sensitivity increases with heat. • Microprocessor -based technology; combination photo and thermal technology. • FlashScan or CLIP ("classic") mode compatible. • Low -temperature warning signal at 40°F ± 5°F (4.44°C 2.77°C). Up to 32 Remote Displays SLC oho 000 FDU-80 LCD2-80 LCD2-80 EIA-485 NFS-320 Sample System Options FSC-851 I ntelliQuadM FAPT-851 Acclimate Plus- FSL-751 FlashScan@ VIEW® FSP-851 FlashScan® photo etc. EIA-485 EIA-232 FSC-851 INTELLIOUAD ADVANCED MULTI -CRITERIA DETECTOR • Detects all four major elements of a fire (smoke, heat, CO, and flame). • Automatic drift compensation of smoke sensor and CO cell. • High nuisance -alarm immunity. • Six sensitivity levels. FCO-851 INTELLIOUADrm PLUS ADVANCED MULTI -CRITERIA FIRE/CO DETECTOR • Detects all four major elements of a fire. • Separate signal for life -safety CO detection. • Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. • Automatic drift compensation of smoke sensor and CO cell. • High nuisance -alarm immunity. • Six sensitivity levels. RELEASING FEATURES • Ten independent hazards. • Sophisticated cross -zone (three options). • Delay timer and Discharge timers (adjustable). • Abort (four options). • Low-pressure CO2 listed. VOICE FEATURES • Integrates with FireVoice-25/50 Series (see DN-7004). • Integrates via serial connection with FireVoice-25/50ZS Series (see DN-7003). HIGH -EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPL Y (6.0 A IN ALARM) • 120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E). • Displays battery current/voltage on panel (with display). DEVICES ACM-8R Relay Control PRN Series Printer NBG-12LX FMM-1 FRM-1 XP6/10 t I 1/0 Modules IDC Relay Contact 2048 annunciator/control �F.—F ACM/AEM-24AT LDM-32 LED Annunciator Custom Graphics 318 point UDACT Dual phone lines to 10 Central Station 7112blok.wmt Page 2 of 6 — DN-7112:H • 08/09/2012 FlashScan, Exclusive World -Leading Detector Protocol At the heart of the NFS-320 is a set of detection devices and device protocol — FlashScan (U.S. Patent 5,539,389). FlashS- can is an all -digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this new protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS-320 to have the largest device per loop capacity in the industry — 318 points — yet every input and output device is sampled in less than two seconds. The microprocessor -based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320 with industry -leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high- speed microcomputer used by the NFS-320. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indica- tive of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre - alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre -alarm operation can be latching or self - restoring, and can be used to activate special control functions. Self -Optimizing Pre -Alarm: Each detector may be set for "Self - Optimizing" pre -alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre -alarm level just above these normal peaks. Cooperating Multi -Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre - alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram. This timesaving feature is a special software routine. The FACP "learns" what devices are physically con- nected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protec- tion in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS-320 software is such that each point entry carries its own program, including control -by -event links to other points. This allows the program to be entered with independent per - point segments, while the NFS-320 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase con- fidence in the site -specific software. It is Windows® -based and provides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-320 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320's flexible system design. Wiring: When designing the cabinet layout, consider separation of power -limited and non -power -limited wiring as discussed in the NFS-320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a Network Control Module or High -Speed Net- work Control Module (HS-NCM can support two nodes; see "Networking Options" on page 4). These modules can be installed in any option board position (see manual), and addi- tional option boards can be mounted in front of them. KDM-R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout). 12 LED Indicators: Power; Fire Alarm; Pre -Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre -Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long -life LED back- light. Product Line Information • "Configuration Guidelines" on page 3 • "Networking Options" on page 4 • "Auxiliary Power Supplies and Batteries" on page 4 • "Audio Options" on page 4 • "Compatible Devices, EIA-232 Ports" on page 4 • "Compatible Devices, EIA-485 Ports" on page 4 • "Compatible Intelligent Devices" on page 4 • "Enclosures, Chassis, and Dress Plates" on page 5 • "Other Options" on page 5 CONFIGURATION GUIDELINES The NFS-320 system ships assembled, description and some options follow. See "Enclosures, Chassis, and Dress Plates" on page 5 for information about mounting peripherals. NOTE: Stand-alone and network systems require a main display. On stand-alone systems, the panel's keypad provides the required display. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYXWorks annunciation device is required. NFS-320: The standard, factory -assembled NFS-320 system includes the following components: one control panel mounted on chassis (120 V operation — ships with grounding cable, bat- tery interconnect cables, and document kit); includes integral power supply mounted to the main circuit board; one primary display KDM-R2 keypad/display; and one cabinet for surface or DN-7112:H • 08/09/2012 — Page 3 of 6 semi -flush mounting. Purchase batteries separately. One or two option boards may be mounted inside the NFS-320 cabinet, - additional option boards can be used in remote cabinets. NFS-320R: Same as NFS-320 above, but in red enclosure. NFS-320C: Based on NFS-320 above. NFS-320C supports installation of an optional ACM -series annunciator in the same cabinet. UL- and ULC-listed. NFS-320CR: Same as NFS-320C but in a red enclosure. NOTE: For additional information on NFS-320C, see DN-60085. NFS-320E: Same as NFS-320 above, but with 240 V operation. TR-320: Trim ring for the NFS-320 cabinet. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi -mode fiber versions available. See DN-6861. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed network communications modules. Wire, single -mode fiber, multi -mode fiber, and media conversion models are available. See DN- 60454. RPT-W, RPT-F, RPT-WF: Standard -network repeater board with wire connection (RPT-W), fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and trans- fer relay, and overcurrent protection. Mounts on two of four posi- tions on a CHS-41L or CHS-4 chassis. See DN-5952. FCPS-24S6/S8: Remote 6 A and 8 A power supplies with bat- tery charger. See DN-6927. BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NFV-25/50: 25 watt, 25 VRMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, and single-/dualchannel Class A or Class B speaker circuits. See DN-7004. NFV-25/50DA: Single channel, 25 Watt, 25 VRMS, emergency voice evacuation panel. See DN-60048. NFV-25/50DAZS: Single channel, 25 Watt, 25 Vrms, emergency voice evacuation panel. Can be automatically activated via the Zone System serial communication link from the NFV-25/50ZS. See DN-60049. NFV-25/50ZS: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-7003 NFV-25/50ZST: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-60337. COMPATIBLE DEVICES, EIA-232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/5: Printer, 40-column, 24 V. Mounted in external back - box. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extend- ing serial data links to remotely located FACPs and/or peripher- als; mount on NFS-320 chassis. See DN-6870. COMPATIBLE DEVICES, EIA-485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by pow- ered -up switch selection) by point to be red, green, or yellow; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered -up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-80: ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD-801-80TM (DN-3198). FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-6820. LCD2-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits. See DN- 4818. TM-4: Transmitter Module. Includes three reverse -polarity cir- cuits and one municipal box circuit; mount on NFS-320 chassis or remotely. See DN-6860. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-4867. UDACT2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides posi- tive non -interfering successive zone coding. Microprocessor - controlled, field -programmable from IBM® -compatible PCs (requires optional programming kit). Mounts in BB-UZC. See DN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB-200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB-200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. See DN-6985. BEAMMRK: Multi -mount kit, FSB-200(S) below. See DN-6985. BEAMSMK: Surface -mount kit, FSB-200(S) below. See DN- 6985. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-20OS: Intelligent beam smoke detector with integral sensi- tivity test. See DN-6985 FSC-851: FlashScan IntelliQuad Advanced Multi -Criteria Detec- tor. See DN-60412. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi -Crite- ria Fire/CO Detector. See DN-60689 . FSI-851: Low -profile FlashScan ionization detector. See DN- 6934. Page 4 of 6 - DN-7112:H • 08/09/2012 FSP-851: Low -profile FlashScan photoelectric detector. See DN-6935. FSP-851T: Low -profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FSP-851 R: Remote -test capable photoelectric detector for use with DNR(W) duct detector housings. See DN-6935. FST 851: FlashScan thermal detector 135°F (57°C). See DN-6936. FST-851 R: FlashScan thermal detector 135°F (57°C) with rate - of -rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high -temperature thermal detector. See DN-6936. FAPT 851: FlashScan Acclimate Plus low -profile multi -sensor detector. See DN-6937. FSL-751: FlashScan VIEW laser photo detector. See DN-6886. DNR: InnovairFlex low -flow non -relay duct -detector housing (order FSP-851 R separately). Replaces FSD-751 PUFSD- 751 RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low -profile relay base. See DN-60054. B224BI: Isolator base for low -profile detectors. See DN-60054. B21OLP: Low -profile base. Standard U.S. style. Replaces B710LP. See DN-60054. B501: European -style, 4" (10.16 cm) base. See DN-60054. B20OS: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6720. FDM-1: FlashScan dual monitor module. See DN-6720. FZM-1: FlashScan two -wire detector monitor module. See DN- 6720. FMM-101: FlashScan miniature monitor module. See DN-6720. FCM-1: FlashScan NAC control module. See DN-6724. FCM-I-REL: FlashScan releasing control module. See DN- 60390. FRM-1: FlashScan relay module. See DN-6724. FDRM-1: FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX: Manual pull station, addressable. See DN-6726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six -circuit supervised control module. See DN-6924. XP6-MA: FlashScan six -zone interface module; connects intelli- gent alarm system to two -wire conventional detection zone. See DN-6925. XP6-R: FlashScan six -relay (Form-C) control module. See DN- 6926. XP10-M: FlashScan ten -input monitor module. See DN-6923. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB -BM Marine System: Protects equipment in shipboard and waterfront applications. For a full list of required and optional equipment, see DN-60688. BB-UZC: Backbox for housing the UZC-256. Required for NFS- 320 applications. Black. For red, order BB-UZC-R. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above, but red. SEISKIT320/1326: Seismic mounting kit. Required for seismic - certified applications with NFS-320 and BB-26. Includes battery bracket for two 26 AH batteries. SEISKIT BB25: Seismic mounting kit for the BB-25. Includes battery bracket for two 26 AH batteries. SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. SEISKIT-PS/2/4: Seismic mounting kit for the FCPS-24S6/S8 and CAB-PS1. Includes battery bracket for two 7 AH or 12 AH batteries. OTHER OPTIONS 411: Slave Digital Alarm Communicator. See DN-6619. 411UDAC: Digital Alarm Communicator. See DN-6746. IPDACT2/2UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for internet communications over customer -provided ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPSPLT: Y-adaptor option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- cator. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. Replaces IPGSM-COM. See DH-60695. NFS-320-RB: Replacement CPU. NOTE: Keypad must be removed before shipping old unit out for repair. • NFS-320-RBE: Replacement CPU, Export. • NFS-320-RBC-FR: Replacement CPU, Canadian French. • NFS-320-RB-PO: Replacement CPU, Portuguese. • NFS-320-RB-POE: Replacement CPU, Export, Portu- guese. • NFS-320-RB-SP: Replacement CPU, Spanish. • NFS-320-RB-SPE: Replacement CPU, Export, Spanish. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. DN-7112:H • 08/09/2012 - Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits ......................................... 1 • Intelligent detectors......................................................... 159 • Addressable monitor/control modules .............................. 159 • Programmable internal hardware and output circuits .......... 4 • Programmable software zones ........................................... 99 • Special programming zones ............................................... 14 • LCD annunciators per NFS-320/-320E ............................. 32 • ACS annunciators per NFS-320/-320E ....................... 32 addresses x 64 points Specifications • Primary input power - NFS-320: 120 VAC, 50/60 Hz, 5.0 A. - NFS-320E: 220/240 VAC, 50/60 Hz, 2.5 A. • Total output 24 V power: 6.0 A in alarm. NOTE. The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. • Standard notification circuits (4): 1.5 A each. • Resettable regulated 24V power: 1.25 A. • Two non-resettable regulated 24V power outputs: - 1.25 A. - 0.50 A. • Non-resettable 5V power: 0.15 A. • Battery charger range: 18 AH - 200 AH. Use separate cabi- net for batteries over 26 AH. • Float rate: 27.6 V. Cabinet Specifications NFS-320 cabinet dimensions: • Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) height; 5.81 in. (14.76 cm) depth. • Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) height; 0.75 in. (1.905 cm) depth. • Trim ring: Molding width is 0.905 in. (2.299 cm). • Shipping weight (without batteries): 36.15 lb. (16.4 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90oF ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80oF. Agency Listings and Approvals The listings and approvals below apply to the basic NFS-320 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL Listed: S635. • ULC Listed: S635 (NFS-320C only, excludes IPDACT). • FM Approved. • CSFM:7165-0028:0243. • MEA:128-07-E. • FDNY: COA#6085. • City of Chicago. When used with the CAB -BM marine system, appropriate seis- mic bracket, and marine approved devices, these ONYX fire alarm control panels are approved by the following agencies: • US Coast Guard: 161.002/50/0 (Standard 46 CFR). • Lloyd's Register: 11/600013 (ENV 3 category). • American Bureau of Shipping. NOTE. For additional information on UL- and ULC-listed model NFS-320C, see DN-60085. For information on NFS-320SYS, see DN-60637. For information on the CAB -BM marine system, see DN-60688. Standards The NFS-320 complies with the following UL Standards and NFPA 72, IBC, and CBC Fire Alarm Systems requirements: • UL 864 (Fire). • UL 1076 (Burglary). • LOCAL (Automatic, Manual, Waterflow and Sprinkler Super- visory). • AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). • REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). • PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). Not applicable for FM. • CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires UDACT). • EMERGENCY VOICE/ALARM. • OT, PSDN (Other Technologies, Packet -switched Data Net- work). • IBC 2000, IBC 2003, IBC 2006, IBC2009 (Seismic). • CBC 2007 (Seismic). NOTI•FIRE•NETTM, IntelliQuadTM, and ONYXWorksTm are trademarks; and Acclimate@ PIusTM, FlashScan@, NOTIFIERO, ONYX@, VeriFire@, and VIEW@ are registered trademarks of Honeywell International Inc. Microsoft@) and Windows@ are registered trademarks of Microsoft Corporation. IBMO is a registered trademark of IBM Corporation. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 6 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6 - DN-7112:H • 08/09/2012 A.2 Calculating the System Current Draws Category CPU-320/E # NACs in use (0, 1, 2, 3 or 4) KAPS-24/E KDM-R2 (Backlight on) SLC loopt: with jumper JP2 cut on CPU or without jumper JP2 cut on CPU NCA, NCA-2 Back -light ON NCA, NCA-2 Back -light OFF NCM-W, NCM-F TM-4 DPI-232 (Refer to manual**) Calculation Column 1 Primary, Non -Fire Alarm Current (amps) city X [current draw]= Total 1 x [0.250] _ [ ] x [0.035] n/a n/a [ ] x [0.100]= 1 x [0.200]= x [0.400]= [ ] x [0.400]= [ ] x [0.200]= [ ] x [0.110]= [ ] x [0.110]= [ ] x [ ]= APS-6R ACPS-2406 ACM-24AT [ ] x [0.016]= ACM-48A [ ] x [0.016]= AEM-24AT [ ] x [0.002]= AEM-48A [ ] x [0.002]= Maximum number of LEDs illuminated on [ ] x [0.0054]= these annunciators during non -fire conditions: AFM-16AT, AFM-32A [ ] x [0.040]= ACM-16AT, ACM-32A [ ] x [0.040]= AEM-16AT, AEM-32A [ ] x [0.002]= AFM-16A [ ] x [0.025]= ACM-8R (refer to manual**) [ ] x [ ]_ LDM (refer to manual**) [ ] x [ ]_ FDU-80 [ ] x [0.0643]= RPT-W, RPT-WF, RPT-F RPT-485W, RPT-485WF UDACT Communicator NFV-25/50 (see manual**) Four -Wire Smoke Detectors Power Supervision Relay EOLR-1 orA77-716B Notification Appliance powered from Power Supply DHX-501, FSD-751RP, FSD-751RF (Duct Detectors with internal relays) Refer to installation document [ ] x [0.0094]= [ ] x [0.017]= [ ] x [0.040]= [ ] x[ ]_ [ ] x[ ]_ [ ] x[ ]_ x [0.020]= x x Calculation Column 2 Primary, Fire Alarm Current (amps) Oty X [current draw]= Total 1 x [0.250] _ [ ] x [0.035] n/a n/a [ ] x [0.100]= 1 x [0.200]= x [0.400]= [ ] x [0.400]= [ ] x [0.200]= [ ] x [0.110]= [ ] x [0.175]= [ ] x [ ]= [ ] x [0.070]= [ ] x [0.070]= [ ] x [0.056]= [ ] x [0.056]= [ ] x [0.056]= [ ] x [0.056]= [ ] x [0.018]= [ ] x [0.065]= [ ] x [ ]= [ ] x [ ]= [ ] x [0.0643]= [ ] x [0.090]= [ ] x [0.017]= [ ] x [0.100]= [ ] x [ ]_ [ ] x [ ]_ [ ] x [ ]_ [ ] x [0.020]= [ ] x [ ]_ [ ] x [ ]_ [ ] x [ ]_ I 1 x [ 1= Calculation Column 3 Secondary, Non -Fire Alarm Current (amps) city X [current draw]= Total 1 x [0.250] _ [ ] x [0.035] 1 x [0.040] [ ] x [0.100]= 1 x [0.200]= x [0.400]= [ ] x [0.400]= [ ] x [0.200]= [ ] x [0.110]= [ ] x [0.110]= [ ] x [ ]= [ ] x [0.025]= [ ] x [0.0013]= [ ] x [0.016]= [ ] x [0.016]= [ ] x [0.002]= [ ] x [0.002]= [ ] x [0.0054]= [ ] x [0.040]= [ ] x [0.040]= [ ] x [0.002]= [ ] x [0.025]= [ ] x[ ]= [ ] x[ ]= [ ] x [0.0643]= [ ] x [0.0094]= [ ] x [0.017]= [ ] x [0.040]= [ ] x[ ]_ [ ] x[ ]_ [ ] x[ ]_ [ ] x [0.020]= x x x Locai tnergy municipal box I I x I 1= Compatible Devices not listed abovell x [ ]_ [ ] x [ ]_ [ ] x [ ]_ [ ] x[ ]_ [ ] x[ ]_ [ ] x[ ]_ Table A. 2 System Draw Current Calculations Maximum current draw for all NACs plus DC output from TB10 is 3.0 A during standby. t Value represents an SLC's maximum current draw. Refer to device datasheets for individual current draws. Ifjumper JP2 is cut, total device current cannot exceed 200 mA; if jumper JP2 is not cut, total device current cannot exceed 400 mA. t The total regulated load current supplied to four -wire smoke detector and power supervision relays cannot exceed 1.25 A. ** Enter the total notification appliance draw from the Main Power Supply, excluding the current from APS-6R supplies. Refer to Device Compatibility Document. tt Refer to manual and/or Device Compatibility Document. See Table 1.1, "Reference Documentation," on page 8 for specific documentation part numbers. Supplement to the NFS-320/E/C Manual P/N 52745EXP:A 07/30/2008 9 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC LISTING No.: 7165-0028:0224 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Notifier One Fire-Lite Place, Northford, CT, 06472 Contact: Brant,Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Model NFS-3030, NFS-3030E, NFS2-3030, NFS2-3030E fire alarm control units. Local, auxiliary, remote station (PPLI), proprietary (PPLI), central station (PPLI), automatic, manual, waterflow and sprinkler supervisory services. Suitable for use as a releasing service, Emergency Voice/Alarm Communication System and Process/Energy Management Equipment. Refer to listee's data sheet for detailed product description and operational considerations. System components: AA-30/-100/-120; Amplifiers ACM-8R/-16AT/-24AT/-32A/-48A; Annunciator Control Modules ACPS-610; Addressable/Charger Power Supply ACPS-2406; Addressable Charger/Power Supply ACT-1/-2/-4/-25/-70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Doors AEM-16AT/-24AT/-32A/-48A; Annunciator Expander Modules AFM-16A/-16AT/-32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch AMG-1/-E; Audio Message Generator AMPS-24, CPS-24; Addressable Main Power Supply APS-6R, APS2-6R; Auxiliary Power Supply ARM-4; Auxiliary Relay Module BDA-25V/-70V; Backup Digital Audio Amplifiers BGRA-SCS, BGRB-SCS, CEF-SCS, RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station BB-17/-25/-100/-200; Battery Box BMP-1; Blank Module BP-4; Battery Panel BP2-4; Dress Panel CA-1/-2; Chassis Page 1 of 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC CAB-3/4 Series, EQ Series; Enclosures *CAB -RP, CAB-RPR; Cabinets CHG-120; Battery Charger CHS-4L/-4MB/-4N/-6/-M3/-PS/-BH1; Chassis CMIC-1, CMIC-RP*; Microphone Assembly CPU2-3030D/CPU2-3030ND; CPU Board CRE-4; Control Relay Expander CRM-4RK; Control Relay Module CRT-2; Display Terminal DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers, Fiber Mode DAA-5070F/DAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF Series; Digital Audio Amplifiers DAA-PS; Power Supply DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DCM-4RK; Dual Channel Module DP-1 B; Blank Panel DP-DISP; Display Dress Panel DR-A4, DR-A4B, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA4B, DR-AA4BR, DR-AA4R; Door Assembly DR-B3F; Door Assembly DR-B4, DR-B4B, DR-B4BR, DR-B4R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DPDW-1 B, DPSW-1 B, XPDP; Dress Panels Page 2 of 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC ress DPI-232; Direct Panel Interface DVC-AO; Digital Voice Command DVC-EM; Extended Memory DVC-EMF/DVC-EMSF; Digital Voice Command/Ext Memory DVC-KD; Keypad Board *DVC-RPU; Remote Paging Unit EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-I-REL; Releasing Control Module FCPS-24S6/S8; Field Charger/Power Supply FFT-7/-7S; Fire Fighter's Telephones FIRSTVISION-LCD; Interactive Firefighters' Display FIRSTVISION-ENC; FirstVision Backbox Enclosure and Door FMM-4-20; Analog Input Module FHS; Fireman's Handset FCM-1; Addressable control module FDM-1; Dual monitor module FDRM-1*; Dual Relay/Monitor Module FMM-1; Monitor module FMM-101; Miniature monitor module FRM-1; Addressable relay module FTM-1; Firephone Control Module FPJ; Fireman's Phone Jack FZM-1; Two -wire detector monitor module HS-NCM-W/-MF/SF/-WMF/-WSF/-MFSF; High Speed Network Control Modules ICE-4; Indicating Control Expander ICM-4RK; Indicating Circuit Module IPDACT-2/-2UD/IPENC; IP Digital Alarm Communicator ISO-X; Isolator Module IZE-A; Initiating Zone Expander Page 3 of 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC IZM-8RK; Initiating Zone Module LCD-80, -160; Liquid Crystal Display Module LCD2-80; Liquid Crystal Display LCM-320; Loop Control Module LDM-32/-E32/-R32; Lamp Driver Module LEM-320; Loop Expander Module MP-1 B; Blank Panel MPS-24B; Power Supply Module NBG-12; Series Addressable Manual Pull Station NBG-12LX; Manual pull station, addressable. See DN-6726 NCA/NCA-2; Network Control Annunciator NCM-W/-F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station, Wire/Fiber NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station, Wire/Fiber ONYXWorks-E W/-N W/N F/-H N W/-H N M F/-H NS F/-TS/-EW-TS/-N F-TS/-H W-TS/-H N M FT/-H NS FT/- HNWT; Graphics PC workstation for NOTI-FIRE-NET Wire/Fiber/with Touch -screen monitors N-ELR; End of Line Resistors NFS-LBB/-LBBR; Battery Box PRN-6; Printer R-120/-2.2K/-27K/-470/-47K; End of Line Resistors RA-400/-400Z; Remote Annunciators RKS-S; Remote Security Keyswitch RM-1/-1SA; Remote Microphone RPJ-1; Remote Paging Jack RPT-W/-F/-485W/-485WF; Repeater SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-B4, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly SCS-8; Smoke Control Station Page 4 of 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC RATING: INSTALLATION: MARKING: APPROVAL: SCE-8; Smoke Control Expander SCE-8L; Smoke Control Expander Lamp STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256/BB--UZC; Universal Zone Coder/Backbox VCE-4; Voice Control Expander VCM-4RK; Voice Control Module VS4095/5; Keltron Remote Printer XP5-C/-M; Transponder XPC-8; Transponder Control Module XPIQ; Transponder Quad Intelligent Audio Module XPM-8/-8L; Transponder Monitor Modules XPP-1; Transponder Processor XPR-8; Transponder Relay Module In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control units suitable for high rise applications for use with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. Page 5 of 6 NOTES: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined with Listing No. 7170-0028:223 *Rev. 05-08-12 gt tSTI� This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an ;.; endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 04/24/2023 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2024 Page 6 of 6 = M L701 no] Connected Life Safety Services (CLSS) Gateway The Honeywell' solution for connecting a system to CLSS cloud, central station, mobile productivity tools, and third party services powered by CLSS. The CLSS Gateway serves as a bridge between a compatible system and the CLSS Cloud platform. It provides a way to securely connect an on -premises system to the Cloud and provides single path from site to Cloud ensuring all CLSS Cloud services and applications use the same audited and monitored method to access the on -premises life safety system. For additional information, refer to the CLSS Gateway UL Listing Document (LS10248- 051 H W-E). CLSS Web App a 0 • CLSS Mobile App tFire Alarm Control Panel FEATURES AND BENEFITS • Connects directly to compatible Honeywell fire alarm control panels (FACPs) or panel networks • Provides seamless integration with the CLSS mobile application • BlueTooth° mobile pairing for Gateway configuration and control capability on Android T" and i0S1 devices CLSS Cloud Platform 0 Central Station CLSS Gateway • Wireless or wired connection from the Gateway to the CLSS Cloud • Panel connection options include standalone panel, networked panel, and standalone with digital voice control • Can be used for portable (without optional cellular module) or permanently installed applications • Serves as afire alarm communicator to the central station * • Collects system data from the connected FACP and sends it to the CLSS Cloud enabling productivity and efficiency tools and features Honeywell AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the HON-CGW-MBB. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Contact Honeywell for the latest listings. • UL: File No. S35608 • CSFM:7300-1637:0504 • FDNY: COA# 2021-TMCOAP-006279-AMND • FCC ID: PV3CGWMB • IC:1609A-CGWMB ORDERING INFORMATION • HON-CGW-MBB: CLSS Gateway with the enclosure OPTIONAL EQUIPMENT • Communication Modules*: - CCM-ATT-HON: Cellular Communication Module forATT° - CCM-VZ-HON: Cellular Communication Module forVerizon° Refer to datasheet HON-62041 for additional information. * Fixed location applications only. CUSTOMER SUPPLIED EQUIPMENT • Mobile Device for the CLSS Gateway application (either iOS or Android) Page 2 of 3 — HON-62034:K • 8/4/2022 HON-CGW-MBB TECHNICAL SPECIFICATIONS Imperial Unit Metric Unit Gateway: Power Operating Voltage Range 18 V DC to 30 V DC Rated Current (Typical) 0.1400 Environment Operating Temperature 32°F to 120°F 0°C to 49°C Storage Temperature 14F°to 140°F -100C to 60°C Relative Humidity Physical Dimensions (with Enclosure) 1%to 93% Non -condensing 2.788" D x 8.023" W x 10.25" H 7cm D x 20.37 cm W x 26 cm H Weight- Gateway+ Enclosure 1.9 lb 861.8 gm Weight - Cellular Module 0.097 lb 44 gm IP Code N/A IP 30 (Cable Glands required) Enclosure Material Black, Flame Retardant ABS-FR (17) Polylac° PA-765 Wireless Transmitter: Power Battery Voltage (VBAT) 3.6 V Output Power @ Module RF Antenna Port 3.4 W Target Power (Typical) 15 dBmA Environment Ambient Temperature 770 F 250 C #Includes cellular module. Meets spectrum mask and EVM compliance. Radio devices operating on the frequencies listed in the table below should not be installed next to each other. Wireless Power Specifications 2.4 GHz TX Power Specifications IEEE 802.11 Mod Rate BW (MHz) Channel Spec (TYP) Units Tol. dB 11b CCK, DSSS 1-11 Mbps 20 1-13 17.5 dBM ±2.0 11g OFDM 6-54 Mbps 20 1-13 15 dBM ±2.0 11n OFDM MCS 0-7 20 1-13 15 dBM ±2.0 11ac OFDM MCS 0-8 20 1-13 14 dBM ±2.0 z TX Power Specifications 11a OFDM 6-54 Mbps 20 36-48 52-64 100-144 15 dBM ±2.0 11n OFDM MCS 0-7 20 36-48 52-64 100-144 15 dBM ±2.0 Honeywell International, Inc. I�O woo www.fire.honeywell.com ENGINEERING B MANUFACTURING QUALITY SYSTEMS THE FUTURE IS WHAT WE MAKE IT Honeywell HON-62034 I K 1 08/22 ©2022 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING & INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTINGS RVIC LISTING No.: 7300-1637:0504 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Honeywell International Inc. One Fire-Lite Place, Northford, CT, 06472 Contact: Brant, Lisa (203) 484-6105 (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTES: Model HON-CGW-MBB Connected Life Safety Services Gateway. The primary function of the product is to provide software services and connection for remote viewing of events. The unit utilizes sole path either Ethernet or Wi-Fi or Cellular communication pathways to connect the host FACP to Honeywell Connected Life Safety Services supplemental program for remote monitoring and data transmission services of FACP events. *The product also supports both sole and dual path communication for digital alarm transmission by connecting to the Supervising Station with selectable reporting paths via Ethernet, Wi-Fi, and Cellular interface. *The methods of communications for dual path are: Primary as Ethernet/Wi-Fi and Secondary as Cellular, or Primary as Cellular and Secondary as Ethernet/Wi-fi. Intended for indoor use and dry locations. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 18-30 VDC In accordance with listee's printed installation instructions, NFPA 70, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and ETL label. Listed as a control unit accessory for use with listee's separately listed compatible commercial and residential fire alarm control units. For a list of compatible control panels, refer to Intertek ATM for Report No. 104270338NYM-001. *Model complies with the applicable requirements in UL 864, 10th Edition. Refer to listee's Installation Instruction Manual for details. Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING &INVESTIGATIONS DIVISION BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE "Revision 6-23-22 VWW This listing is based upon technical data submitted by the applicant. OSFM Fire Engineering staff has reviewed the test :••°"" °�c results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 05/04/2023 Authorized By: Victor Wong, Program Coordinator Fire Engineering & Investigations Division Listing Expires: 06/30/2024 Page 2 of 2