Loading...
HomeMy WebLinkAboutBPOL2021-0288BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 08/31/2021 ISSUED DATE: 11/18/2021 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 80423 CHAMPIONS WY BPOL2021-0288 775220021 $15,000.00 Owner:RREF II CWC LAQ LLC 5927 PRIESTLY DR STE 110, CARLSBAD, CA 92008 Applicant:TESERRA TESERRA 38822 El Desierto Rd P O BOX 1280, Palm Desert, CA 92211 Contractor:TESERRA TESERRA / 656128 38822 El Desierto Rd P O BOX 1280, Palm Desert, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Printed: 7/10/26 2:50 pm Page 1 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2021-0288 80423 CHAMPIONS WY BUILDING PERMIT Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Quinta at (760) 777-7125 immediately for correction. Printed: 7/10/26 2:50 pm Page 2 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2021-0288 80423 CHAMPIONS WY BUILDING PERMIT WOODBRIDGE / POOL AND SPA AT SIDE YARD *** POOL AND SPA AT SIDE YARD [PATRELL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Use of Permit Construction Details Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BPOL2021-028 8 $1.00 BSAS SB1473 FEE $1.00 $5.00 TECHNOLOGY ENHANCEMENT FEE $5.00 $201.25 SWIMMING POOL/SPA $201.25 $109.48 SWIMMING POOL/SPA PC $109.48 $10.00 RECORDS MANAGEMENT FEE $10.00 $326.73 $326.73 Total for Invoice PERMIT-BPOL2021-0288 Grand Total for Permit $326.73 $326.73 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 08/31/2021 0:00 FINAL** v.1 Inspection PRE-PLASTER v.1 Inspection DECK BOND v.1 Inspection UNDERGROUND GAS v.1 Inspection UNDERGROUND PLBG v.1 Inspection UNDERGROUND ELEC v.1 Inspection PRE-GUNITE v.2 Inspection PRE-GUNITE v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections Printed: 7/10/26 2:50 pm Page 3 of 4 Permit Type: Permit Number: Property Address: Pool BPOL2021-0288 80423 CHAMPIONS WY BUILDING PERMIT A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 7/10/26 2:50 pm Page 4 of 4 PERMIT INSPECTION HISTORY REPORT (BPOL2021-0288) FOR CITY OF LA QUINTA Pool 08/31/2021Application Date:Permit Type:775220021Parcel Pool Construction (Private)11/18/2021Work Class:Issue Date:80423 CHAMPIONS WY LA QUINTA, CA 92253 Address: Finaled Expiration Date:Status:Description:WOODBRIDGE / POOL AND SPA AT SIDE YARD *** POOL AND SPA AT SIDE YARD [PATRELL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:RREF II CWC LAQ LLC TESERRA TESERRA TESERRA TESERRA Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date 11/23/2021 Pre-Gunite ECON:2111220257 09535 Disapproved Mark Hunt No Complete Comments: eTRAKiT Inspection Request NOTES Created By TEXT Created Date System Administrator 11/22/2021 2:57 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 11/22/2021 Mark Hunt 3" MINIMUM CLEARANCE REBAR TO EARTH IN SEVERAL AREAS. 1. BOND BEAM AT SPA 2. BOTTOM CORNER OF SPA 3. BOTTOM CORNER AT DEEP END 11/23/2021 Mark Hunt 3" MINIMUM CLEARANCE REBAR TO EARTH IN SEVERAL AREAS. 1. BOND BEAM AT SPA 2. BOTTOM CORNER OF SPA 3. BOTTOM CORNER AT DEEP END 11/23/2021 11/24/2021 Pre-Gunite ECON:2111230256 31455 Approved Duane Clayton No Complete Comments: eTRAKiT Inspection Request 78-495 Calle Tampico Page 1 of 4July 13, 2026 PERMIT INSPECTION HISTORY REPORT (BPOL2021-0288) Pool 08/31/2021Application Date:Permit Type:775220021Parcel Pool Construction (Private)11/18/2021Work Class:Issue Date:80423 CHAMPIONS WY LA QUINTA, CA 92253 Address: Finaled Expiration Date:Status:Description:WOODBRIDGE / POOL AND SPA AT SIDE YARD *** POOL AND SPA AT SIDE YARD [PATRELL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:RREF II CWC LAQ LLC TESERRA TESERRA TESERRA TESERRA Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date NOTES Created By TEXT Created Date System Administrator 11/23/2021 2:56 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 11/23/2021 Duane Clayton - SEE APPROVED SITE PICTURE FOR ENGINEERING IN ATTACHMENTS. - MINIMUM OF FOUR BOND POINTS REQUIRED. 11/24/2021 12/13/2021 Underground Electrical ECON:2112100246 59346 Approved Mark Hunt No Complete Comments: eTRAKiT Inspection Request NOTES Created By TEXT Created Date System Administrator 12/10/2021 2:46 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 12/10/2021 Underground Gas ECON:2112100246 59345 Approved Mark Hunt No Complete Comments: eTRAKiT Inspection Request NOTES Created By TEXT Created Date System Administrator 12/10/2021 2:46 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 12/10/2021 Underground Plumbing ECON:2112100247 00347 Approved Mark Hunt No Complete Comments: eTRAKiT Inspection Request 78-495 Calle Tampico Page 2 of 4July 13, 2026 PERMIT INSPECTION HISTORY REPORT (BPOL2021-0288) Pool 08/31/2021Application Date:Permit Type:775220021Parcel Pool Construction (Private)11/18/2021Work Class:Issue Date:80423 CHAMPIONS WY LA QUINTA, CA 92253 Address: Finaled Expiration Date:Status:Description:WOODBRIDGE / POOL AND SPA AT SIDE YARD *** POOL AND SPA AT SIDE YARD [PATRELL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:RREF II CWC LAQ LLC TESERRA TESERRA TESERRA TESERRA Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date NOTES Created By TEXT Created Date System Administrator 12/10/2021 2:46 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 12/10/2021 12/16/2021 Deck Bond ECON:2112150316 42122 Approved Mark Hunt No Complete Comments: eTRAKiT Inspection Request NOTES Created By TEXT Created Date System Administrator 12/15/2021 3:16 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 12/15/2021 01/24/2022 Pre-Plaster ECON:2201200321 20083 Approved Mark Hunt No Complete Comments: eTRAKiT Inspection Request NOTES Created By TEXT Created Date System Administrator 1/20/2022 3:21 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 01/20/2022 02/04/2022 Final Building ECON:2202030325 25121 Approved Mark Hunt No Complete Comments: eTRAKiT Inspection Request 78-495 Calle Tampico Page 3 of 4July 13, 2026 PERMIT INSPECTION HISTORY REPORT (BPOL2021-0288) Pool 08/31/2021Application Date:Permit Type:775220021Parcel Pool Construction (Private)11/18/2021Work Class:Issue Date:80423 CHAMPIONS WY LA QUINTA, CA 92253 Address: Finaled Expiration Date:Status:Description:WOODBRIDGE / POOL AND SPA AT SIDE YARD *** POOL AND SPA AT SIDE YARD [PATRELL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Owner:Contractor:Applicant:RREF II CWC LAQ LLC TESERRA TESERRA TESERRA TESERRA Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Required?CompleteActual Start Date NOTES Created By TEXT Created Date System Administrator 2/3/2022 3:25 PM TESERRA Contact Name: TESERRA Site Address: 80423 CHAMPIONS WY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 02/03/2022 78-495 Calle Tampico Page 4 of 4July 13, 2026 Bu i l d e r s o f E x c e p t i o n a l O u t d o o r L i v i n g 83 83 7,155 SF PLAN 6A-L 135'135' 53' 53'PL PL PL PL J G GA S G A S G A S GAS GAS GAS GAS GAS GAS GAS GA S G A S AC 3'-6" WD 5'-0" WD 9" WD US 25'-6" 14' HL M LH A S 21'-6" 5'-2" 6'-5" 4' 8' 11'-1" 15'-1" 9'-11" 4' 5 JETS PER PLAN (1) JANDY HYDROCOOL NICHELESS COLOR LED BOBCAT SEE SUPER JANDY 460 SQ.FT. JANDY 270 HP AUT VS JANDY 400,000 BTU IQ 904 P/S TRU CLEAR DUAL PORT AUTO F.M. BROOM DAM WALL YES YES SEE SUPER IQ20-A CONCRETE YES - 0 - TILE DAM WALL (3) JANDY HYDROCOOL NICHELESS COLOR LED CONCRETE YES CONCRETE YES -9" WD 86 - 1 0 0 A V E . 5 4 C O A C H E L L A C A 9 2 2 3 6 PH : ( 7 6 0 ) 3 9 8 - 9 2 2 2 F A X : ( 7 6 0 ) 3 9 8 - 9 2 5 5 CA L I C E N S E N o . 6 5 6 1 2 8 SPECIFICATIONS A CUSTOM PROJECT FOR: REVISIONS DATE: 123456 SELECTIONS CONSTRUCTION AUTHORIZATION decking excavation / steel spa specifications plumbing gunite owner responsibilities masonry pebble / plaster fencing MISCELLANEOUS NAME COMMUNITY JOB ADDRESS CITY HOMEOWNER MOBILE PROJECT MANAGER MOBILE DATE DESIGNED BY PROJECT MGR.CHECKED BYSCALE MB # 18"=1' STONE TILE POTS/BOWLS PEBB/PLAS BOULDERS DRAINAGE NOTE: DIG PRE-GUNITE UNDERGROUND MASONRY DECK PRE-PEBBLE SALES FIELD SIGNATURE(S)DATE (1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION. (2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS, AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA. (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE PRIOR TO PREPLASTER INSPECTION. (6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS -- DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. OWNER TO: SIZE SURFACE AREA OF POOL ONLY PERIMETER DEPTHS MIN.MAX X SIZE X SQ. FT. SPA DAM WALL WIDTH NO. OF JETS LIGHT RAISED SPA AT SPILLWAY TYPE SPECIAL NOTES GLASS TILE WATERLINE R.B.B. TILE TYPE ACCESS FROM ELEVATION DEEP END RAMP LOVE SEAT CONCRETE REMOVAL SOD REMOVAL TREE REMOVAL BY LOADS LOADS IRRIGATION REMOVAL BY IRRIGATION REPAIR FT. TAN SHELF DEPTH ROCK POCKETS CENTERS FILTER SIZE POOL PUMP BOOSTER PUMP ADDL PUMP ADDL PUMP HEATER CONTROL SYSTEM CHLORINATOR WIRELESS CONTROL SKIMMER TYPE FILL LINE GAS LINE STUBS W.F. ATTACHED TO POOL OTHER W.F. LIGHTS IN POOL STUB SET EQUIPMENT DEEP END RAMP EXTEND 2nd STEP LOVESEAT COPING R.B.B. - SEE STEEL REMOVE & REHANG GATE REVERSAL GATE HEIGHT FENCE TYPE DEEP HEAT RETURNS ECLIPSE DRAINS EYE BALL FITTINGS LIGHTS SPA LIGHTS POOL SEAT WALLS EQUIP. WALLS RETAINING WALLS PLANTER WALL PROP. EXT. WALLS STEPS SPILLWAY TYPE SIZE R.B.B. FACING COPING TYPE MOW STRIP BANDS SAND AND VISQUEEN TILE BASE STEP FACE STEPS SLEEVES DRAINS DOUBLE CANTILEVER CANTILEVER EXPANSION JOINTS FINISH SQ. FT. TILE SIZE SIZE SIZE SIZE SIZE EST. START EST. COMPLETION 30" R.B.B. Drainage and irrigation for planters and pots, by others, unless otherwise noted. LN. FT. POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY, FIELD LAYOUT WILL VARY EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS * NO EXISTING LANDSCAPE LIGHTING IN REAR YARD * NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD 78 POOL & SPA COMBINED * PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY FT.24" R.B.B. FT.18" R.B.B. FT.12" R.B.B. FT.6" R.B.B. CHAMPIONS WAY PLUMBING SIZE PROJECT MANAGER EMAIL TRIM TILE EQUIPOTENTIAL BONDING GRID WELDED WIRE MESH REBAR BARBECUE COUNTERTOP BARBECUE SAND SET PAVERS STUCCO PAINT Q360 INFLOOR MISTING SYSTEM TRELLIS LIGHTS IN SPA LIGHTS IN W.F. DEEP HEAT PACKAGE Q360 INFLOOR MISC. PAVERS CONCRETE HOMEOWNER EMAIL FIREPIT ANTI VORTEX ECLIPSE DRAINS ANTI VORTEX CUSTOMER NUMBER: DBX # TANNING SHELF AT 9" WATER DEPTH WITH ONE UMBRELLA SLEEVE adjusted setbacks per plan (see delta 1)11.02.21 npt: onyx blue - light blue 2019 california building code ( BASED ON 2018 IBC ) 2019 california mechanical code ( BASED ON 2018 UMC ) 2019 california electrical code ( BASED ON 2017 NEC ) 2019 california energy green code electrical: EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. safety features: * ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) 2019 california plumbing code ( BASED ON 2018 UPC )TITLE 24, PART 5 GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED 2019 california residential code ( BASED ON 2018 IRC ) 2019 california energy code EXISTING 200876 SPA STEP SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED CATALINA BELGARD PAVERS, COLOR MONTECITO MAIN HOUSE 200 AMP ELECTRICAL PANEL GAS METER 175' - 2" POLYPROPYLENE GAS PIPE * GAS LINE IN DRIVEWAY IN 3" PVC SLEEVE ELECTRIC CONDUIT POOL EQUIPMENT: 400,000 BTU HEATER *ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED POOL / SPA LIGHT JUNCTION BOX POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER POOL EQUIPMENT 50 AMP SUBPANEL WITH 36" CLEARANCE AT FRONT AND SIDE GUNITE 25'-6"14'-0" 281 SQ.FT. 79 LN.FT. 337 SQ.FT. / 79 LN.FT. 3'-6"5'-0" 7'-0"6'-0"42 26 SEE NOTES 38 SQ. FT.PAVER PADS 863 SQ. FT.PAVERS SPA AT -0- WITH (5) HYDRO THERAPY JETS PER PLAN DAM WALL WIDTH TO BE 10 12" FINISHED GUNITE POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED PAVERS STEPPING PADS WITH CATALINA BELGARD PAVERS, COLOR MONTECITO (4) TILE DECK JETS LOCATED IN WATERLINE OF POOL, JETS OPERATED BY CIRCULATION PUMP WITH DEDICATED ACTUATOR VALVE (4) TILE DECK JETS (1) JANDY HYDROCOOL NICHELESS COLOR LED (3) JANDY HYDROCOOL NICHELESS COLOR LED (1) JANDY HYDROCOOL NICHELESS COLOR LED BROOM FINISH MESA BUFF COLORED POOL COPING BROOM FINISH MESA BUFF COLORED CONCRETE 127 SQ.FT.POOL COPING 45 SQ.FT.CONCRETE FRONT PAD catalina - color montecito mesa buff broom finish aqua blue pebble sheen EXISTING 5'-0"H BLOCK WALL EXISTING 5'-0"H SELF LATCHING/SELF CLOSING GATE - OPENING OUT EXISTING 5'-0"H BLOCK WALL EXISTING 5'-0"H BLOCK WALL NEIGHBOR 1 1 BPOL2021-0288 POOL AND SPA AT SIDE YARD [PATRELL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. 11/17/2021 ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, GREEN BUILDING AND ENERGY CODES AND THE LA QUINTA MUNICIPAL CODE Safety Features – New pools and spas shall be equipped with at least two of the following drowning prevention safety features. (H&S § 115922 – SB No. 442) • Enclosure that isolates the pool or spa from dwelling. • Removable Mesh fencing, a gate that is self-latching and closing and can accommodate a key lockable device. • Safety pool cover. • Exit alarms on doors that provide direct access to pool or spa. • A self-closing self latching device placed on doors providing direct access to pool or spa. • An alarm that when placed in a pool or spa, will sound upon detection. (Surface Motion, Pressure, Sonar, Laser)