Loading...
MUP 2014-1003RV54XC504 City of La Quinta 78-495 Calle Tampico La Quinta, California 92253 PHONE: 760.777.7125 FAX: 760.777,1233 Office Use Only Case Number Accepted Assigned 30 -Day By To Deadline ,Ruftofq__100� I ?_� I I Notes: MINOR USE PERMIT APPLICATION RE C�j�"i�o&& JUL j 12014 CITY Or LA ,VINTA COMMUNITY DEVELOPMENT Finance Stamp Sections A, B and C are to be completed bV the applicant in their entirety and shall be accompanied by all listed plans, studies, reports and exhibits listed in Section D unless specifically waived by the appropriate City staff member and noted thereon. SECTION A - PROJECT INFORMATION Project Name: Sprint Site ID: RV54XC504 - 2.5 Equipment Deployment Project Description: Modification to existing wireless facility. The specifics are as follows removal of (9) existing panel antennas, install (4) new batteries within existing battery rack, install (3) panel antennas and RRH's, install (1) fiber cable and install (1) ALU base band kit within existing equipment cabinet. All associated proposed equipment will be located inside the existing lease space APN #(s): 658-180-029 & 658-190-011 Site Address/ Location: 49-499 Eisenhower Drive General Plan: Specific Plan: Proposed Phases: NSA Zoning Proposed Use Related Cases: Existing Wireless Telecommunications Facility CUP 2001-054 & Minor Use Permit 2012-1044 Minor Use Permit Application Page 1 of 8 City of La Quinta - Planning Department - 760.777.7125 05.20.13 R\Application Submittal Forms\Applications\MUP\MUP Application - 05.20.13.doc SECTION B - STATEMENT OF OPERATIONS The purpose of this form is to provide a detailed statement outlining the day-to-day operation of the proposed project. Any approval related to this application will be based on the information provided and will therefore be subject to the continued operation of the proposed project consistent with the information provided. Please be aware that any activities beyond those described here may result in the need to amend your use permit in the future, thus it is encouraged that the information provided be based on the ultimate operation level of the proposed use. Description of proposed use: No change to existina use, unmanned Woreless Telecommunocatmon E,-&� Hours of operation: 24/7 Number of employees: N/A List any other local, state or federal licenses or permits required: None. Types of equipment and processes used: See the attached letter. Describe any hazardous materials used, stored, or produced on-site: NSA - Existing wireless Facility Describe any other special characteristics specific to the proposed use: None Minor Use Permit Application Page 2 of 8 City of La Quinta • Planning Department ■ 760.777.7125 05.20.13 R\Application Submittal Forms\Applications\MUP\MUP Application - 05.20.13.doc SECTION C - APPLICANT/OWNER INFORMATION Applicant: SBA Communications - Katelyn Voss (949) 398-8050 ext 203 (Name) (Phone) 980 Roosevelt, Suite 210 7j- ,`, r. -e , r /,4 9 kvoss@sbasite.com (Mailing Address) (Email) Owner(s): KSL Desert Resort. Inc (760) 564-4111 (Name) (Phone) 49-499 Eisenhower Drive, La Quinta, CA (Mailing Address) (Email) Architect: Jeffrey Rome & Associates - Jeffrey Rome (949) 760-3929 (Name) (Phone) 131 Innovation Drive, Suite 100, Irvine, CA 92617 pauliname-irainc net (Mailing Address) (Email) C-020876 (California State License #) Applicant Certification I certify that 1 have read this application packet in its entirety and understand the City's submittal and review process and the requirements for this application. I further certify that each application item submitted as part of this application is consistent with the minimum required contents for that item as described in Section D of this application. I understand and agree that if during the processing of the application, it is determined the information does not strictly meet such standards or contains errors or omissions, clarification and/or supplemental information may be required and the preparation of such information may be considered, in the Planning Director's judgment, an unreasonable delay and will result in a suspension of processing time limits in accordance with the California Code of Regulations, Title 14, Section 15109. Applicant's Signature: .G Date: 7/9/14 Print Name: Katelyn S. Voss Owner Certification 1 certify under the penalty of the laws of the State of California that 1 am the property owner of the property that is the subject matter of this application and I am authorizing and hereby do consent to the filing of this application and acknowledge that the final approval by the City of La Quinta, -if any, may result in restrictions, limitations and construction obligations being imposed on this real prQperty. Owner/Authorized Agent Signature*: Date: Print Name(s): * An authorized agent for the owner must attach a notarized letter of authorization from the legal property owner. Any off-site work identified on the plans must be accompanied by a statement of authorization with a notarized signature of the subject property owner. Minor Use Permit Application Page 3 of 8 City of La Quinta - Planning Department - 760.777.7125 05.20.13 R\Application Submittal Forms\Applications\MUP\MUP Application - 05.20.13.doc Date Paid: Friday, July 11, 2014 Paid By: SBA COMMUNICATIONS Cashier: PJU Pay Method: CHECK 2080166 ��.�AW 0 `ea,y 4, a a 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 September 16, 2014 Mordecai Fayas SBA Communications 980 Roosevelt, Suite 210 Irvine, Ca, 92620 (760) 777-7000 FAX (760) 777-7101 F111 COPY SUBJECT: MINOR USE PERMIT 2014-1003 WIRELESS FACILITY MODIFICATION AT 49499 EISENHOWER DRIVE Dear Mr. Fayas: The Community Development Department has reviewed and approved your request to remove nine (9) existing panel antennas, and install three (3) new replacement panel antennas mounted with three (3) new RRH units; install one new fiber cable and associated battery back-up and 2.5 equipment in existing cabinets shelter, for an existing telecommunication facility located at 49999 Eisenhower Drive, within the La Quinta Resort and Spa property. The approval of this application is subject to the exhibits on file for this Minor Use Permit and the following Findings and Conditions of Approval: FINDINGS 1. Consistency with the General Plan: The proposed equipment at the existing telecommunication facility are consistent with the goals, objectives and policies of the General Plan, in that the proposed equipment is intended to enhance community access to quality wireless communication services. 2. Public Welfare: Approval of the new equipment for an existing telecommunication facility will not create conditions materially detrimental to the public health, safety and general welfare. 3. The proposed new equipment at the existing telecommunication facility will minimize adverse visual impacts as the proposed replacement antennas and associated equipment will occur entirely on and within existing facilities, and result in a reduction of the number of antennas, from nine to three. 4. The proposed new and replacement equipment is designed to facilitate continued function of the existing -ant Qnna array, without modifying the height or other pre-existing conditions to maintain the service provider's objectives for coverage within this portion of the community. 5. The proposed new and replacement equipment is necessary to improve community access to wireless services. CONDITIONS 1. The applicant/property owner agrees to defend, indemnify, and hold harmless the City of La Quinta (the "City"), its agents, officers and employees from any claim, or litigation arising out of the City's approval of this project. This indemnification shall include any award toward attorney's fees. The City of La Quinta shall have the right to select its defense counsel in its sole discretion. The City of La Quinta shall promptly notify the applicant of any claim, action, or proceeding and shall cooperate fully in the defense. 2. The applicant shall comply with all provisions of La Quinta Municipal Code Section 9.170 "Wireless Telecommunication Facilities". 3. The applicant shall comply with all provisions contained in Conditions of Approval for Conditional Use Permit 2001-055 (CUP 01-055). 4. The applicant is permitted to install the following on the existing tower array and within the existing equipment shelter: remove nine (9) existing tower mounted panel antennas, and install three (3) new replacement panel antennas mounted with three (3) new RRH units; install one new fiber cable and associated battery back-up and 2.5 equipment, in existing equipment cabinets located within the existing equipment shelter. All new and replacement equipment on the array shall be painted to match as appropriate. 5. New cables running from the equipment shelter to the new antennas shall be contained within the existing cable tray between the tower and the equipment enclosure as shown. All cables shall be interior of the tower and shall not be visible from surrounding properties. 6. The applicant shall obtain all necessary building permits from the City's Building Division, and is responsible for meeting all applicable plan check submittal requirements. 7. The City may elect to add Conditions to this application request to mitigate any problems that arise not previously addressed herein. This decision may be appealed to the Planning Commission by any party who submits the necessary_ paperwork and filing_fee of $1,573.00 to this office within 15 days of the date of approval of this permit. If you have any questions, please contact me at (760) 777-7069 or via email at wnesbit la-guinta.orq. Sincerely, Wallace Nesbit Principal Planner c: Building Division File; CUP 2001-055 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 August 8, 2014 Mordecai Fayas SBA Communications 980 Roosevelt, Suite 210 Irvine, Ca, 92620 (760) 777-7000 FAX (760) 777-7101 FILE COPY SUBJECT: MINOR USE PERMIT 2014-1003 WIRELESS FACILITY MODIFICATION AT 49499 EISENHOWER DRIVE Dear Mr. Fayas: On July 11; 2014, the City of La Quinta Community Development Department received the above-mentioned application for plans associated with a proposed modification of a wireless cell tower facility at 49499 Eisenhower Drive (La Quinta Resort and Club). The first step in the City's development application review process is to determine if your application meets the minimum requirements for processing. These requirements are listed and described in the application form you signed and submitted as part of your application packet. Unless specifically waived, each item listed on the application form, in the manner described, is required to determine your application complete and acceptable for processing. In review of your application, it is determined that your application, as submitted, is determined to be incomplete and cannot be accepted for processing until the following items are submitted and determined adequate for review. • The application is not signed by the property owner. Provide written authorization for the application submittal from KSL Desert Resort Inc, represented as property owner. Once the outstanding items are received and determined acceptable for processing, you will receive a letter of completeness and your application will undergo final review and processing. If you have any questions, please contact me at (760) 777-7069 or via email at wnesbit a la-guinta.org. Sincerely, Wallace Nesbit Principal Planner r Wally Nesbit From: Mordecai Fayas <mfayas@sbasite.com> Sent: Monday, September 08, 2014 5:11 PM To: Wally Nesbit Cc: Rebecca Rimbach • Subject: RE: SPRINT Site RV54XC504 / 49499 Eisenhower Drive Attachments: RV54XC504 Ground lease.pdf Hi Wally, Thank you for the verification. I have attached our lease with KSL Desert Resorts. Under section 3, it allows Sprint the ability to replace, maintain, or modify the site to fit their needs. It also allows access rights to the site during regular business hours (without approval) and 24/7 in cases of emergency. Will this document suffice? Much Appreciated, Mordecai Fayas Site Development Manager 949-398-8050 x206 + O 224-548-1163 + C From: Wally Nesbit [mailto:wnesbitWa-quinta.org] Sent: Monday, September 08, 2014 8:20 AM To: Mordecai Fayas . Cc: Rebecca Rimbach Subject: RE: SPRINT Site RV54XC504 / 49499 Eisenhower Drive Hi Mordecai. I verified that we would need to have Resort authorization as the site is on their property and you would need their authorization for access. Wallace H. Nesbit, Principal Pkumer Community 1)evelopinent Department City ol• La QuirILI 78495 Calk "Tampico La Quinta CA 92253 Direct:760-777-7069 rax: 760-777-7011 epmiaui@l: wnesbitla-guinta.oi R/ 611 //YW" From: Mordecai Fayas [mailto:mfayasC&sbasite.com] Sent: Sunday, September 07, 2014 3:45 PM To: Wally Nesbit Cc: Rebecca Rimbach Subject: RE: SPRINT Site RV54XC504 / 49499 Eisenhower Drive . Hi Wally, Have you had a chance to review the below with regards to the property owner signature? Please advise at your earliest convenience. Much Appreciated, Mordecai Fayas Site Development Manager 949-398-8050 x206 + O 224-548-1163 + C From: Mordecai Fayas Sent: Monday, August 25, 2014 3:32 PM To: 'Wally Nesbit' Cc: Rebecca Rimbach (rrimbachO)sbasite.com) Subject: RE: SPRINT Site RV54XC504 / 49499 Eisenhower Drive Hi Wally, Sorry, I have been terribly busy as of late. In reviewing the property owner authorization requirement, I am concerned with this portion. Since we (SBA Communications Corp) own the tower structure, the resort does not have a legal say in what we do to the tower or what equipment we put on it. Is this a requirement that applies to tower structures that are owned by 3`d parties? Much Appreciated, Mordecai Fayas Site Development Manager 949-398-8050 x206 + O 224-548-1163 + C From: Wally Nesbit[mailto:wnesbit(a)la-quinta.org] Sent: Friday, August 08, 2014 10:10 AM To: Mordecai Fayas Subject: SPRINT Site RV54XC504 / 49499 Eisenhower Drive Hello Mordecai — attached is a 30 -day completeness letter, which follows -up to my email of August 5. At this point I will await submittal of property owner authorization for this application. Please contact me with any questions. Thanks, Wallace H. Nesbit, Principal Planner Community Development Department. City of 1a Quinta 78405 Calle "I'ampico La Quinta CA 92253 Direct: 760-777-7069 Fae:760-777-7011 email: wnesbit(1la-quinta.org (il/. 6T �,ea." ORfGENA • L April 1999 PCS SITE AGREEMENT Page 1 of 4 Site Name: La Qulnta Resort Site I.D. No.: RV•544C•504 A 1. Proyertpand Use. Owner is the owner of the real property and improvements described in Exhibit A ("Property") and hereby leases to Cox PCS Assets, L.L,C., a Delaware limited liability company ('Cox'), the site described below: [Check appropriate box(es)[ 1. Land consisting of approximately 36 square feet, upon which Cox will construct its antenna structure ("Monopalml 2. Building exterior space on the roof of a building co nsisting of approximate ly 325 square feet for placement of base station equipment: 3. Space required for cable runs to connect PCS equipment and antennas and for emergency power connection, in the location(s) on the Property ("Site") shown on Exhibit B together with a non-exclusive easement for access thereto and to the appropriate, in the discretion of Cox, source of electric and telephone facilities. The Site will be used by Cox for the purpose of installing, removing, replacing, maintaining, modifying and operating, at its expense. a personal communications service system facility ("PCS'). including, without limitation, related antennas, equipment, back-up power sources (includinggenerators and fuel storage tanks), cable, wiring and fixtures and, dapplicable. an antenna structure. Cox shall have access to the Site during regular business hours, and twenty-four hours per day, seven days per week (24/7) access only for cases of emergency. Cox will use the Site in a manner which will not unreasonably disturb the occupancy of Owner's other tenants. Owner agrees to permit Cox ingress and egress to the Site to conduct such surveys, structural strength analysis, subsurface boring tests and other activities of a similar nature as Cox may deem necessary, at the sole cost of Cox. 2. Term. The term of this Agreement (the "initial Term") is five (5) years. commencing on the date ("Commencement Date") both Cox and Owner have executed this Agreement- This Agreement will be automatically renewed for four (4) additional terms (each a "Renewal Term") of five (5) years each, unless Cox provides Owner notice of intention not to renew not less than ninety (90) days prior to the expiration of the Initial Term or any Renewal Term. 3. Rent. Until the date which is sixty (60) days after the issuance of a h„ilrlino nArm;t torr ,,,;n -one-time aggregate payment of the receipt of which Owner acknowledges. Thereafter, rent will be paid in advance in eoual be pro -rated. Rent for each Renewal Term will be the monthly rent in effect for the final year of the Initial Term or prior Renewal Term, as the case may be, increased by 4, Title and Oulet Possession. Owner represents and agrees (a) that it is the owner of the Site; (b) that it has the right to enter into this Agreement; (c) that the person signing this Agreement has the authority to sign: (d) that Cox is entitled to access to the Site at all times and to the quiet possession of the Site throughout the Initial Term and each Renewal 'Perm so long as Cox is not in default beyond the expiration of any cure period; and (e) chat Owner shall not have unsupervised access to the Site or to the PCS equipment. S. Assignment/Subletting. Cox may assign or transfer this Agreement or sublet all or any portion of the Site without notice to or consent of Owner. Owner may assign or transfer this Agreement without notice to or consent of Cox. 6. Notices. All notices must be in writing and are effective only when deposited in the U.S. mail, certified and postage prepaid, or when sent via overnight delivery. Notices to Cox are to be sent with reference to the Site Name and I.D. listed above, to 4683 Chabot Drive. Suite 100, Pleasanton, CA 94588 with a copy to Sprint Law Department, 6391 Sprint Parkway. Mailstop: KSOPHT0101-Z2020, Overland Park, Kansas 66251-2020, Attention: Sprint PCS Real Estate Attorney. Notices to Owner must be sent to the address shown underneath Owner's signature. T. Improvements. Cox may, at its expense, make such improvements on the Site as itdeems necessary from time to time for the operation of the PCS. Owner agrees to cooperate with Cox with respect to obtaining any required zoning approvals or other governmental approvals or permits for the Site and such improvements. Upon termination orexpiration of this Agreement, Cox shall remove its equipmentand improvements and will restore the Site to substantially the condition existing on the Commencement Date, except for underground conduit and foundations, ordinary wear and tear and damage by fire or other casualty loss. 8. Compliance with Laws. Owner represents that the Property (including the Site), and all improvements located thereon. are and C:%CLIEYt SMSPRIA'RSoothemCalitem&aAiversidelRv 54-XC-504(A11Pcs Site Agrmmcm 2.rpd FebniM 14. 2001 jI V ClihPO_F ;,n,,vv.las1io.com April 1999 PCS SITE AGREEMENT Page 2 of 4 Site Name: La Guinta Resort Site I.D. No.: Ry54-xC•504(A1 shall remain in substantial compliance to the extent required with cured solely by the payment of money, or (b) thirty (30) days building, life/safety. disability and other laws, codes and following receipt of notice from the non -defaulting party with regulations of applicable governmental authorities. Cox will respect to a default which may not be cured solely by the payment substantially comply to the extent required with all applicable laws of money, then, in either event, the non -defaulting party may directly relating to Cox's operation of the PCS and the pursue any remedies available to it against the defaulting parry improvements constructed by Cox at the Site. under applicable law, including, but not limited to, the right to terminate this Agreement- If the non -monetary default may not 9. Interference, Cox will resolve technical interference problems reasonably be cured within a thirty (30) day period. this with other equipment located at the Sire as of the Commencement Agreement may not be terminated if the defaulting party Date or with any equipment that Cox attaches to the Site at any commencesactiontocure the default withinsuchthirtydayperiod future date when Cox desires to add additional equipment to the and proceeds with due diligence to fully cure the default. Site. Owner will not permit or suffer the installation of any future equipment which (a) results in technical interference problems with Cox's then existing equipment. or (b) encroaches onto the Site. 10. Utilities. Owner represents that utilities adequate for Cox's use of the Site are available. Cox will pay for all utilities used by it at the Site. Owner will cooperate with Cox In Cox's efforts to obtain utilities from any location provided by Owner or the servicing utility, including signing any easement or other instrument reasonably required by the utility company. 11. Termination (A) Cox may terminate this Agreement at any time by notice to Owner without further liability if (i) Cox does not obtain all permits, consents, easements, non -disturbance agreements or other approvals (collectively, 'approval") reasonably desired by Cox or required from any governmental authority or any third party related to or reasonably necessary to operatethe PCS system, or if any such approval is canceled, expires or is withdrawn or terminated, or (ii) if Owner fails to have proper ownership of the Site or authority to enter into this Agreement, or (iii) if Cox, for anv other reason, in its sole discretion, determines that it will be unable to use the Site. Upon termination, all prepaid rent shall be retained by Owner, unless termination is pursuant to (ii) above or is a result of Owners default. (B) Anytime after the fifth (5th) anniversary of the Commencement Date. Owner shall have the right to terminate this Agreement at Owner's sole discretion; provided, however, that Owner gives Cox not less than twelve (12) months prior written notice. 12. Default. If either parry is in default under this Agreement for a period of (a) fifteen (15) days following receipt of notice from the non -defaulting parry with respect to a default which may be 13. Indemni . Owner and Cox each indemnifies the otheragainst and holds the other harmless from any and all costs (including reasonable attorneys' fees) and claims of liability or loss which arise out of the ownership, use and/or occupancy of the Site by the indemnifying parry. This indemnity does not apply to any claims arising from the sole negligence or intentional misconduct of the indemnified party. The indemnity obligations tinder this Section will survive the termination of this Agreement. 14. Hazardous Substances. Owner represents that it has no knowledge of any substance, chemical or waste (collectively, 'substance') on or under the Site or Property that is identified as hazardous, toxic or dangerous in any applicable federal, state or local law or regulation, except for swimming pool cleaning supplies. Cox will not introduce or nue any such substance on the Site in violation of any applicable law. Owner shall indemnify and hold Cox harmless from and against all claims, actions, damages. fines, liabilities, costs and expenses (including attorneys' and expert fees) arising, directly or indirectly. from the presence of any substanceon,underoraround the Property orthe Site. unlesssald substance was actually brought onto the Property or Site by Cox. This obligation to inclemnifyCoxshall include damages. costs and expenses incurred in connection with any investigation, cleanup, remediation, monitoring, removal or restoration related to the presence of any substance. This indemnity shall survive the expiration or termination of this lease. 15. Subordination/Non-disturbance. This Agreement is subordinate to any lien, mortgage or deed of trust now of record against the Property. However, promptly after this Agreement is fully executed, Owner will use diligent efforts to obtain a non- disturbance agreement reasonably acceptable to Cox from the holder of any such mortgage or deed of trust. CAMEVIS SMSPRIA-MoudemCaUrnrnla%RlrmidekRV-54•XC.SN(A)1PCSSiteAlp u e.0 pd Febnary 14, 2001 ClibPDF - vvtvird.laslio.com / April 1999 PCS SITE AGREEMENT Page 3 of 4 Site Name: La Ouinta Resort Site I.D. No.: RV-54-XG504(A) 16. Tates. Cox will be responsible for payment of all personal reimburse Cox for the reasonable costs incurred by Cox to restore property taxes assessed directly upon and arising solely from its use the damaged areas to the condition which existed immediately of the PCS on the Site. Cox will pay to Owner any increase in real prior thereto. Owner will maintain and repair all other portions property taxes attributable solely to any improvements to the Site of the Property of which the Site is a part in a proper operating and made by Cox within sixty (60) days after receipt of satisfactory reasonably safe condition. documentation indicating calculation of Cox's shares of such real estate taxes and payment of the real estate taxes by Owner. Owner 19. Miscellaneous. (a) This Agreement applies to and binds the will pay when due all other real estate taxes and assessments heirs, successors, executors, administrators and assigns of the attributable to the Property of which the Site is a part. parties to this Agreement; (b) This Agreement is governed by the 17. Insurance. At all times during the term of this Agreement, Cox shall carry and maintain in full force and effect, at its sole expense, the following insurance policies with insurance companies having a A.M. Best & Co. rating of A -:VIII or better and licensed to do business in the state of California. Such policies shall include a provision requiring a minium of thirty (30) days notice to Owner of any change or cancellation. Cox shall provide Owner with a certificate(s) of insurance evidencing the policies listed below prior to the commencement of this Agreement. Owner shall be named as additional insured as its interest may appear for the insurance policies described below: (a) Comprehensive General Liability insurance in an amount of One Million Dollars ($1.000,000.00) combined single limit per occurrence for bodily injury and property damage liability, including the following coverages: contractual liability, personal injury, broad form property damage and independent contractors: (b) Business Automobile coverage form insurance on all vehicles used in connection with- the Services, in an amount of Five Hundred Thousand Dollars ($500,000.00) combined single limits for bodily injury and property damage per occurrence: and (c) Workers Compensation Insurance In accordance with the provisions of the Workers Compensation Acts of the State of California. Each party hereby waives its right of recovery against the other for any loss or damage covered by any insurance policies maintained by the waiving party. Each party will cause each insurance policy obtained by it to provide that the insurance company waives all rights of recovery against the other party in connection with any damage covered by such policy. 18. Maintenance. Cox will be responsible for repairing and maintaining the PCS and any other improvements installed by Cox at the Site in a proper operating and reasonably safe condition; provided, however, if any such repair or maintenance is required due to acts of Owner, its agents or employees, Owner shall laws of the State in which the Site is located: d delayep to Gam (d) This Agreement (including the Exhibits) constitutes the entire agreement between the parties and supersedes all prior written and verbal agreements, representations, promises or understandings between the parties, and any amendments to this Agreement must be in writing and executed by both parties: (e) If any provision of this Agreement is invalid or unenforceable with respect to any party, the remainder of this Agreement or the application of such provision to persons other than those as to whom it is held invalid or unenforceable, will not be affected and each provision of this Agreement will be valid and enforceable to the fullestextent permitted by law: and (1) The prevailing party in any action or proceeding in court or mutually agreed upon arbitration proceeding to enforce the terms of this Agreement is entitled to receive its reasonable attorneys fees and other reasonable enforcement costs and expenses from the non -prevailing party. The following Exhibits are attaco and made a part of this Agreement: Exhibit A. B (rrtd$r SIGNATURE PA O9YS G.1CLIEWSUSB\SPRIN-rSouthemC.difamia%R.iu"s RV-54-xC-504(A)tPCSSte AFeermnL2.wpd F'ebmary 14. 2001 ClihPDF r April 1999 PCS SITE AGREEMENT Page 4 of 4 Site Name: La Quints Resort Site I.D. No.: RV•54.XC•504(Al OWNER: KSL Desert Resorts, Inc., a Delaware corporation By: Print Name: Its: ChairmaRVthe Board/Presidenent (CIRCLE ONE) By: ---- - r Print Name: Its: Secretary/Assistant Secretary, �Financial Assistant Treasurer (CIRCL Address: 49499 Eisenhower Drive La Quinta. CA 92253 Attn: Contracts Administrator Phone: (760) 564-4111 Dated: .2001 COX: COX PCS ASSE . L.L.C., a Delaware limited liability com a y By: Kellya le Its: Regio irector of Site Development Dated: 2001 GiCL1ENMS&SPRINRSoulhem CallfomiaU4icenldHR V.54•XC•504 (A)UCS Site Ag wmemlupd Fetruary 14.2001 Clil)PDF EXHIBIT A to PCS SITE AGREEMENT DESCRIPTION OF OWNER'S PROPERTY Site Mame: La Quinta Resort Site I.D. No.: RV -54 -XC -504(A) Description of Owner's Property: The real property situated in the City of La Quinta, County of Riverside, State of California commonly described as 49-499 Eisenhower Drive and more particularly described as: EXHIBIT "A" Lot 30 as shown on the Map of Tract No. 28545-3, in the City of La Quinta, Countv of Riverside, State of California, as filed in Book 269, Pages 1 through 6 inclusive of maps, records of Riverside County, ^,alifornia . Excepting therefrom that portion described as follows: Beginning at the Northeast corner of lot C of said Tract No. 28545-3, thence along the Southerly line of Lot C of Tract No. 28545-1, as filed in Book 268, Pages 89 to 92 inclusive of Maps, records of Riverside County, California, South 890 52' 22" East, 1.33 feet; thence leaving said Southerly line, South 00 07' 3811 West, 104.83 feet to the Easterly prolongation of the Southerly line of Lot C of said Tract No. 28545-3; thence along said line, North 890 52' 23" West, 1.33 feet to the Southeast corner -of said Lot; thence along the Easterly line of said Lot C, North 00 07' 38" East, 104.83 feet to the point of beginning. Owner Initials Cox Initials CIihPDF Permit Reviews Page 1 of 1 Enter Permit Number MUP201471003 14 4 1 of 1 > >B 4, 100% >!s Find I NextrM tM EI Permit Reviews - City of La"Quinta FM,OF. Y:V Permit Number: MUP2014-1003 Applied: 7/10/2014 Approved: Issued: Finaled: Status: SUBMITTED Parent Permit: Parent Project: Details: MODIFICATION TO EXISTING WIRELESS FACILITY. LA QUINTA RESORT Description: Site Address: 49499 EISENHOWER DR City, State Zip Code: LA QUINTA, CA 92253 Applicant: SBA COMMUNICATIONS Owner: KSL DESERT RESORT Contractor: <NONE> View_ Report_ LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: AUTO 7/15/2014 7/16/2014 PL ASSIGNMENT PLANNING BUCKET Notes: Review Group: PLANNING MUP 7/15/2014 7/15/2014 7/17/2014 PL FILE CREATION BEATRICE ACOSTA APPROVED Notes: Printed: Tuesday, 15 July, 2014 10 f 1 C"Wil,"", http://laquinta.crw.comltrakit9lDocumentV iewer.aspx?&report=lDocumentsiPERMITSlPe... 7/15/2014 City of La Quinta Statement of Operations Sprint Site ID: RV54XC504 / SBA Site ID: CA45914 Property Address: 49-499 Eisenhower Drive, La Quinta, CA 92253 APN: 658-180-029 & 658-190-011 Zoning: C-6 Project Representative: Katelyn Voss, Senior Property Specialist SBA Communications Corporation 980 Roosevelt, Suite 210 Irvine, CA 92620 949.398.8050 x203 kvoss@sbasite.com JUL 15 LJ'A CYTV OF LA CoMMUNYTV DEVEL01°i'b'1.: SBA Communications Corporation 980 Roosevelt, Suite 210 Irvine, CA 92618 T + 949.398.8050 sbasite.com General Project Information: Sprint is in the process of deploying the latest generation in base station, radio and core equipment which is expected to result in improved antennas, power, spectrum efficiency and capacity. Wireless facilities are being modified and optimized with the replacement of existing antennas, network equipment and software bringing together multiple spectrum bands, or airwaves, on a single, multimode base station. Sprint's plan is to consolidate multiple network technologies into one seamless network with the goal of increasing efficiency and enhancing network coverage, call quality and data speeds for customers across the Untied States. Sprint will extend its 4G leadership position in the U.S. by adding LTE technology to enhance its current 4G offerings, with plans to launch LTE on its existing 2.5 GHz spectrum. Sprint expects its 4G coverage footprint to cover 250 million people when the build -out is complete. The implementation of multimode technology throughout the Sprint network is designed to: • Enhance Service — Improve quality and data speed; improve in -building coverage and coverage within the network footprint. • Create Network Flexibility— Ensure the most effective expansion of 4G. • Reduce Operating Costs — Deliver capital efficiency, lease reductions, roaming savings and backhaul efficiencies. • Improve Environmental Sustainability— Reduce carbon footprint and energy consumption needs. Project Proposal: Sprint is requesting approval to modify the existing wireless facility. The modification will consist of removing nine (9) existing panel antennas and installing three (3) panel antennas and RRHs, which will be mounted behind the new panel antennas, installing one (1) fiber cable and additional 2.5 equipment within existing cabinet. All associated proposed equipment will be located inside the existing lease space compound. The proposed modification does not require any variances or conditions inconsistent with the general plan or zoning regulations. w Should you have any questions, or need additional information, please feel free to contact me. Much Appreciated, Katelyn Voss Senior Property Specialist SBA COMMUNICATIONS CORPORATION 980 Roosevelt, Suite 210 Irvine, CA 92620 949.398.8050 x203 + T 949.246.9358 + C kvoss .sbasite.com Your Signal Starts Bere. S B Al EXHIBIT B to PCS SITE AGREEMENT DESCRIPTION OF COX'S SITE Site Name: La Quinta Resort Site I.D. No.: RV -54 -XC -504(A) [Site Plans Attached Consisting of -6- Pages] Note: CoxmayreplacethisDescriptionofCox'sSitewiththeplanssubmittedtothelocaijurisdictionforabuildingpermitand/or as -built drawings depicting the Site and PCS. Such replacement description shall be deemed apart of this Agreement and shall be binding on Owner and Cox. Owner Initials Cox Initials ClibPDF n,v.l.faslic�.i:o+» 0 • IRtUl:IvcL,P OC- r CITY OF LA QUINTA COMMUNITY DEVELOPMENT w Vp.� Nil ... ����, • /r-'. ,. Ali ��,�'lllll nr r 204- ioo3- �A e�.�,�„��S wfC all ofl 193 PROPERTY OWNER: KSL DESERT RESORT, INC. 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 CONTACT: APRIL SHUTE PHONE: (760) 564-4111 ASSESSORS PARCEL NUMBER: 658-180-029, 658-190-011 PROPERTY INFORMATION: LATITUDE: 33.6869' (33' 41' 12.84" N) LONGITUDE: —116.3103' (116' 18' 37.0794" W) JURISDICTION: CIN OF LA QUINTA ZONING CLASSIFICATION: C-6 CALIFORNIA BUILDING CODE: 2013 EDITION EXISTING CONSTRUCTION TYPE: V—N PROPOSED CONSTRUCTION TYPE: V—N EXISTING OCCUPANCY: U PROPOSED OCCUPANCY: U EXISTING USE: TELECOMMUNICATIONS PROPOSED USE: TELECOMMUNICATIONS LEASE AREA: NO CHANGE IN EXISTING LEASE AREA SPRINT 330 COMMERCE #100 IRVINE, CALIFORNIA 92602 CONTACT: NIKKI ALBA, NETWORK PROJECT MANAGER III PHONE: (714) 862-0349 EMAIL: NIKKI.ALBAOSPRINT.COM PROJECT ARCHITECT JEFFREY ROME & ASSOCIATES 131 INNOVATION DRIVE SUITE 100 IRVINE, CALIFORNIA 92617 CONTACT: PAULINA MENDOZA PHONE: (949) 760-3929 EMAIL: PAULINAM®JRAINC.NET PROJECT MANAGER SBA COMMUNICATIONS CORPORATION MORDECAI FAYAS PHONE: (949) 398-8050 EXT. 206 EMAIL: MFAYASOSBASITE.COM PLANNING CONSULTANT SBA COMMUNICATIONS CORPORATION KATELYN VOSS PHONE: (949) 398-8050 EXT. 203 CONSTRUCTION MANAGER: SPRINT DAVE MURRAY PHONE: (951) 207-7542 EMAIL: DAVID.MURRAY@SPRINT.COM AAV COMPANY: VERIZON POWER COMPANY: SOUTHERN CALIFORNIA EDISON SITE INFORMATION 1l h'�13fr � Cad k@ -d Yatr�tn�a u , SITEQ �! PROJECT: SITE NAME: SITE CASCADE: SBA SITE: SITE ADDRESS: SITE TYPE: 2.5 EQUIPMENT DEPLOYMENT LA QUINTA RESORT RV54XC504 CA45914-A-01 w 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 MONOPALM ILL C 5111 p N VICINITY MAP SCOPE OF WORK CALIFORNIA STATE CODE COMPLIANCE SPRINT PROPOSES THAT ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFIRMING TO THESE CODES. • CALIFORNIA ADMINISTRATIVE CODE (INCL TITLE 24 & 25). • 2013 CALIFORNIA BUILDING CODE. • CIN/ COUNTY ORDINANCES. • BUILDING OFFICIALS & CODE ADMINISTRATORS (BOCA). • 2013 MECHANICAL CALIFORNIA CODE. • ANSI/ EIA -222—F LIFE SAFETY CODE NEPA-101. • 2013 CALIFORNIA PLUMBING CODE. • 2013 CALIFORNIA ELECTRICAL CODE. • 2013 LOCAL BUILDING CODE. ACCESSIBILITY REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2013 CALIFORNIA BUILDING CODE. DIG ALERT UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA vLL FREE 1-800-227-2600 AT LEAST TWO DAYS BEFORE YOU DIG CODE BLOCK SHEET INDEX APPROVAL SIGNATURE SPRINT PROPOSES TO MODIFY ITS EXISITING ANTENNA AND EQUIPMENT IN AN EXISTING PROJECT SHEET DESCRIPTION A MANAGER UNMANNED TELECOMMUNICATIONS FACILITY, IK T-1 TITLE SHEET 05/28/14 100% CD'S MANAGER C T-2 OUTLINE SPECIFICATIONS RF ENGINEER JE • REMOVE (9) EXISTING SPRINT IDEN ANTENNAS.T-3 SITE OUTLINE SPECIFICATIONS ACQUISITION • INSTALL (3) SPRINT 2.5 PANEL ANTENNAS. 17✓L7 T-4 SIGNAGE & BATTERY INFORMATION "y" • INSTALL (3) RRH'S BEHIND PANEL ANTENNAS WITH REQUIRED JUMPERS. A,Pr"" ROVEO ev PLANNING PROPERTY aFlhAax • INSTALL (1) FIBER CABLE. OWNER A-1 SITE PLAN �� _ OAT _ v • INSTALL (1) SPRINT 2.5 EQUIPMENT IN EXISTING MMBTS CABINET. A-2 EQUIPMENT PLANS 3 i n2 Slf Nh • INSTALL (1) STRING OF BATTERIES WITHIN EXISTING BATTERY BACKUP UNIT CABINET. A-3 ANTENNA PLANS A-4 ELEVATIONS A-5 ANTENNA & RRH DETAILS A-6 FIBER CABLE SPECIFICATIONS IhermK.A fp>i A-7 EQUIPMENT DETAILS E-1 GROUNDING DETAILS E-2 DC POWER DETAILS N VICINITY MAP SCOPE OF WORK CALIFORNIA STATE CODE COMPLIANCE SPRINT PROPOSES THAT ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFIRMING TO THESE CODES. • CALIFORNIA ADMINISTRATIVE CODE (INCL TITLE 24 & 25). • 2013 CALIFORNIA BUILDING CODE. • CIN/ COUNTY ORDINANCES. • BUILDING OFFICIALS & CODE ADMINISTRATORS (BOCA). • 2013 MECHANICAL CALIFORNIA CODE. • ANSI/ EIA -222—F LIFE SAFETY CODE NEPA-101. • 2013 CALIFORNIA PLUMBING CODE. • 2013 CALIFORNIA ELECTRICAL CODE. • 2013 LOCAL BUILDING CODE. ACCESSIBILITY REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2013 CALIFORNIA BUILDING CODE. DIG ALERT UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA vLL FREE 1-800-227-2600 AT LEAST TWO DAYS BEFORE YOU DIG CODE BLOCK SHEET INDEX APPROVAL SIGNATURE DATE PROJECT INIT. A MANAGER 90% CD REVIEW IK s 05/28/14 100% CD'S MANAGER C 06/16/14 RF ENGINEER JE SITE ACQUISITION , CONSULTANT PROPERTY aFlhAax OWNER L. trm v C SIGNATURE BLOCK IhermK.A fp>i ' (17 4 N VICINITY MAP SCOPE OF WORK CALIFORNIA STATE CODE COMPLIANCE SPRINT PROPOSES THAT ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFIRMING TO THESE CODES. • CALIFORNIA ADMINISTRATIVE CODE (INCL TITLE 24 & 25). • 2013 CALIFORNIA BUILDING CODE. • CIN/ COUNTY ORDINANCES. • BUILDING OFFICIALS & CODE ADMINISTRATORS (BOCA). • 2013 MECHANICAL CALIFORNIA CODE. • ANSI/ EIA -222—F LIFE SAFETY CODE NEPA-101. • 2013 CALIFORNIA PLUMBING CODE. • 2013 CALIFORNIA ELECTRICAL CODE. • 2013 LOCAL BUILDING CODE. ACCESSIBILITY REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2013 CALIFORNIA BUILDING CODE. DIG ALERT UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA vLL FREE 1-800-227-2600 AT LEAST TWO DAYS BEFORE YOU DIG CODE BLOCK SHEET INDEX APPROVAL SIGNATURE DATE PROJECT INIT. A MANAGER 90% CD REVIEW IK CONSTRUCTION 05/28/14 100% CD'S MANAGER C 06/16/14 RF ENGINEER JE SITE ACQUISITION PLANNING CONSULTANT PROPERTY OWNER SPRINT REPRESENTATIVE SIGNATURE BLOCK Sprint 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 AI�T�//� �cE�Y L• iPq� I. * C-020876 OF wffi R VISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: TITLE SHEET SHEET NUMBER: T-1 THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. SECTION 01 100 - SCOPE OF WORK THE WORK: SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, AND PORTIONS THEREOF. PRECEDENCE: SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES INCLUDING THE STANDARD CONSTRUCTION DETAILS FOR WIRELESS SITES AND THE CONSTRUCTION DRAWINGS, INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. SITE FAMILIARITY: CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ON—SITE SUPERVISION: THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. DRAWINGS, SPECIFICATIONS AND DETAILS REQUIRED AT JOBSITE: THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM MOBILIZATION THROUGH CONSTRUCTION COMPLETION. A. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. METHODS OF PROCEDURE (MOPS) FOR CONSTRUCTION: CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN THE FOLLOWING INSTALLATION AND COMMISSIONING MOPS. A. TOP HAT DATE B. HOW TO INSTALL A NEW CABINET C. BASE BAND UNIT IN EXISTING UNIT D. INSTALLATION OF BATTERIES E. INSTALLATION OF HYBRID CABLE F. INSTALLATION OF RRU'S G. CABLING H. TS -0200 REV 4 — ANTENNA LINE ACCEPTANCE STANDARDS I. SPRINT CELL SITE ENGINEERING NOTICE — EN 2012-001, REV 1. J. COMMISSIONING MOPS SECTION 01 200 - COMPANY FURNISHED MATERIAL AND EQUIPMENT COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. SECTION 01 300 - CELL SITE CONSTRUCTION NOTICE TO PROCEED: NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. SITE CLEANLINESS: CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH, AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS. SECTION 01 400 - SUBMITTALS & TESTS ALTERNATES: AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION MANAGER FOR APPROVAL. SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED, TESTS AND INSPECTIONS: A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND PROJECT DOCUMENTATION. B. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. COAX SWEEPS AND FIBER TESTS PER TS -0200 REV 4 ANTENNA LINE ACCEPTANCE STANDARDS. 2. AGL, AZIMUTH AND DOWNTILT PROVIDE AN AUTOMATED REPORT UPLOADED TO SITERRA USING A COMMERCIAL MADE—FOR THE PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL (AAT). INSTALLED AZIMUTH, CENTERLINE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 4. ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING; 1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS — ANTENNALIGN ALIGNMENT TOOL (AAT) 2. SWEEP AND FIBER TESTS 3. SCANABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT 4. ALL AVAILABLE JURISDICTIONAL INFORMATION 5. PDF SCAN OF REDLINES PRODUCED IN FIELD 6. A PDF SCAN OF REDLINE MARK—UPS SUITABLE FOR USE IN ELECTRONIC AS—BUILT DRAWING PRODUCTION 7. LIEN WAIVERS 8. FINAL PAYMENT APPLICATION 9. REQUIRED 'FINAL CONSTRUCT10i4' FHOTOS 10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS 11. ALL POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA (SPRINTS DOCUMENT REPOSITORY OF RECORD). 12. CLOSEOUT PHOTOGRAPHS: a PROVIDE PHOTOGRAPHS OF FINAL PROJECT PER THE FOLLOWING LIST. ADDITIONAL PHOTOGRAPHS MAY BE REQUIRED TO SUPPORT ACCEPTANCE PROCESSES (i) MAIN HYBRID CABLE ROUTE (MINIMUM TWO PHOTOS) (ii) PHOTOS OF EACH ANTENNA AND RRU (iii) MANUFACTURERS NAME TAG FOR ALL SERIALIZED EQUIPMENT (iv) PULL AND DISTRIBUTION BOXES INTERMEDIATE BETWEEN RRU'S AND MMBS (DOOR OPEN) (v) MMBS CABINET WITH DOOR OPEN SHOWING MODIFICATIONS (vi) POWER CABINET, DOORS OPEN, BATTERIES INSTALLED (vii) BREAK OUT CYLINDERS (viii) ASR SIGNAGE FOR SPRINT OWNED TOWERS (ix) RADIATION EXPOSURE WARNING SIGNS (x) PHOTOGRAPH FROM EACH SECTOR FROM APPROXIMATELY RAD CENTER, OF ANY NEW ANTENNA AT HORIZON. I b LOAD PHOTOS TO SITERRA PROJECT LIBRARY 15. IN 15 CREATE NEW CATEGORY; 2.5 DEPLOYMENT, AND SECTION; PERMANENT CONSTRUCTION. LABEL PHOTOS WITH SITE CASCADE AND VIEW BEING DEPICTED. CAMERAS USED TO TAKE PHOTOGRAPHS SHALL GPS ENABLED SUCH THAT THE GPS COORDINATES ARE INCLUDED JN TrF PHOTO MEDIA—r1LE 1NFORPAT'A_`4%. COMMISSIONING: PERFORM ALL COMMISSIONING AS REQUIRED BY APPLICABLE MOPS INTEGRATION: PERFORM ALL INTEGRATION ACTIVITIES AS REQUIRED BY APPLICABLE MOPS SECTION 07 500 - ROOF CUTTING. PATCHING AND REPAIR SUMMARY: THIS SECTION SPECIFIES CUTTING AND PATCHING EXISTING ROOFING SYSTEMS WHERE CONDUIT OR CABLES EXIT THE BUILDING ONTO THE ROOF OR BUILDING—MOUNTED ANTENNAS, AND AS REQUIRED FOR WATERTIGHT PERFORMANCE. ROOFTOP ENTRY OPENINGS IN MEMBRANE ROOFTOPS SHALL BE CONSTRUCTED TO COMPLY WITH LANDLORD, ANY EXISTING WARRANTY, AND LOCAL JURISDICTIONAL STANDARDS. 1.4 SUBMITTALS: A. PRE—CONSTRUCTION ROOF PHOTOS: COMPLETE A ROOF INSPECTION PRIOR TO THE INSTALLATION OF SPRINT EQUIPMENT ON ANY ROOFTOP BUILD. AT A MINIMUM INSPECT AND PHOTOGRAPH (MINIMUM 3 EA.) ALL AREAS IMPACTED BY THE ADDITION OF THE SPRINT EQUIPMENT. 8. PROVIDE SIMILAR PHOTOGRAPHS SHOWING ROOF CONDITIONS AFTER CONSTRUCTION (MINIMUM 3 EA.) C. ROOF INSPECTION PHOTOGRAPHS SHOULD BE UPLOADED WITH CLOSEOUT PHOTOGRAPHS. SECTION 09 900 - PAINTING QUALITY ASSURANCE: A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. COMPLY WITH ALL ENVIRONMENTAL REGULATIONS FOR VOLATILE ORGANIC COMPOUNDS. MATERIALS: A. MANUFACTURERS: BENJAMIN MOORE, ICI DEVOE COATINGS, PPG, SHERWIN WILLIAMS OR APPROVED EQUAL. PROVIDE PREMIUM GRADE, PROFESSIONAL—QUALITY PRODUCTS FOR COATING SYSTEMS. PAINT SCHEDULE: A. EXTERIOR ANTENNAE AND ANTENNA MOUNTING HARDWARE: ONE COAT OF PRIMER AND TWO FINISH COATS. PAINT FOR ANTENNAE SHALL BE NON—METALLIC BASED AND CONTAIN NO METALLIC PARTICLES. PROVIDE COLORS AND PATTERNS AS REQUIRED TO MASK APPEARANCE OF ANTENNAE ON ADJACENT BUILDING SURFACES AND AS ACCEPTABLE TO THE OWNER. REFER TO ANTENNA MANUFACTURER'S INSTRUCTIONS WHENEVER POSSIBLE. B. ROOF TOP CONSTRUCTION: TOUCH UP — PREPARE SURFACES TO BE REPAIRED. FOLLOW INDUSTRY STANDARDS AND REQUIREMENTS OF OWNER TO MATCH EXISTING COATING AND FINISH. PAINTING APPLICATION: 1. INSPECT SURFACES, REPORT UNSATISFACTORY CONDITIONS IN WRITING; BEGINNING WORK MEANS ACCEPTANCE OF SUBSTRATE. 2. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR PREPARATION, PRIMING AND COATING WORK. COORDINATE WITH WORK OF OTHER SECTIONS. 3. MATCH APPROVED MOCK—UPS FOR COLOR, TEXTURE, AND PATTERN. RE—COAT OR REMOVE AND REPLACE WORK WHICH DOES NOT MATCH OR SHOWS LOSS OF ADHESION. 4. CLEAN UP, TOUCH UP AND PROTECT WORK. TOUCHUP PAINTING: 1. GALVANIZING DAMAGE AND ALL BOLTS AND NUTS SHALL BE TOUCHED UP AFTER TOWER ERECTION WITH "GALVANOX," "DRY GALV," OR "ZINC—IT.- 2. FIELD TOUCHUP PAINT SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. ALL METAL COMPONENTS SHALL BE HANDLED WITH CARE TO PREVENT DAMAGE TO THE COMPONENTS, THEIR PRESERVATIVE TREATMENT, OR THEIR PROTECTIVE COATINGS. SECTION 11 700 - ANTENNA ASSEMBLY, REMOTE RADIO UNITS AND CABLE INSTALLATION SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRU'S, AND CABLE EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE. ANTENNAS AND RRU'S: THE NUMBER AND TYPE OF ANTENNAS AND RRU'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. HYBRID CABLE: HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE. CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. JUMPERS AND CONNECTORS: FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRU'S AND ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540, OR FXL 540. SUPER—FLEX CABLES ARE NOT ACCEPTABLE. JUMPERS BETWEEN THE RRU'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC, OUTDOOR RATED COAXIAL CABLE. DO NOT USE SUPERFLEX OUTDOORS. JUMPERS SHALL BE FACTORY FABRICATED IN APPROPRIATE LENGTHS WITH A MAXIMUM OF 4 FEET EXCESS PER JUMPER AND HAVE CONNECTORS AT EACH END, MANUFACTURED BY SUPPLIER. IF JUMPERS ARE FIELD FABRICATED, FOLLOW MANUFACTURER'S REQUIREMENTS FOR INSTALLATION OF CONNECTORS REMOTE ELECTRICAL TILT (RET) CABLES: MISCELLANEOUS: INSTALL SPLITTERS, COMBINERS, FILTERS PER RF DATA SHEET, FURNISHED BY SPRINT. ANTENNA INSTALLATION: THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, AND FEED ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE CONSTRUCTION DRAWINGS. CONTINUE SHEET T-3 S prinf 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 /�c.D ARt�T\ 4_ ,Vx.Y E q FCS * I C-020876 I * �ql FfB. ? gr �F A CAIN/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: OUTLINE SPECIFICATIONS SHEET NUMBER: T-2 A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL. THE PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. 1. HYBRID CABLES INSTALLATION: A. THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. 1. FASTENING MAIN HYBRID CABLES: ALL CABLES SHALL BE PERMANENTLY FASTENED TO THE COAX LADDER AT 4'-0" OC USING NON—MAGNETIC STAINLESS STEEL CLIPS. 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA), WITHIN THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES: o. FIBER: SUPPORT FIBER BUNDLES USING %" VELCRO STRAPS OF THE REQUIRED LENGTH 0 18" OC. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL. b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL. 3_ FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR STAINLESS STEEL BU'TT'ERFLY CLIPS. 4. CABLE INSTALLATION: a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. c. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURES RECOMMENDED MAXIMUM BEND RADIUS. 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 4. 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA—NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE — EN 2012-001, REV 1 WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: A. ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2" ELECTRICAL TAPE EXTENDING 2" BEYOND TUBING. PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL. 2. SELF—AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF—AMALGAMATING TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF—AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SELF—AMALGAMATING TAPE, 3. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED. ?. OP _I^i FL" -MF OR .JOB cITF IS NOT ACCEPTABLE SECTION 11 800 - INSTALLATION OF MULTIMODAL BASE STATIONS (MMBS) AND RELATED EQUIPMENT A. THIS SECTION SPECIFIES MMBS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS, BASE BAND UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI). B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPLICABLE INSTALLATION MOPS. C. COMPLY WITH MANUFACTURERS INSTALLATION AND START—UP REQUIREMENTS DC CIRCUIT BREAKER LABELING: A. LABEL CIRCUIT BREAKERS ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE — EN 2012-001, REV 1. SECTION 11 800 - INSTALLATION OF MULTIMODAL BASE STATIONS (MMBS) AND RELATED EQUIPMENT SUMMARY: A. THIS SECTION SPECIFIES MMBS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS, BASE BAND UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI). B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPLICABLE INSTALLATION MOPS. C. COMPLY WITH MANUFACTURERS INSTALLATION AND START—UP REQUIREMENTS SUPPORTING DEVICES: A. MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING: 1. ALLIED TUBE AND CONDUIT 2. B—LINE SYSTEM 3. SUNISTRUT DIVERSIFIED PRODUCTS 4. THOMAS & BETTS B. FASTENERS: TYPES, MATERIALS, AND CONSTRUCTION FEATURES AS FOLLOWS: 1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE. 2. POWER—DRIVEN THREADED STUDS: HEAT—TREATED STEEL, DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 3. FASTEN BY MEANS OF WOOD SCREWS ON WOOD. 4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING—TENSION CLAMPS ON STEEL. 7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. 8. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. 9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. SUPPORTING DEVICES: A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH NEC. B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. E. USE VIBRATION AND SHOCK—RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. ELECTRICAL IDENTIFICATION: A. UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET, INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM. B. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD. SECTION 26 200 - ELECTRICAL MATERIALS AND EQUIPMENT CONDUIT: A. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN UNFINISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE. RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1, FEDERAL SPECIFICATION WW—C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SHALL BE THREADED — SET SCREW OR COMPRESSION FITTINGS WILL NOT BE ACCEPTABLE. RGS CONDUITS SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND. B. UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE FOR DIRECT BURIAL AS APPLICABLE. JOINTS SHALL BE BELLED, AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL. C. TRANSITIONS BETWEEN PVC AND RIGID (RGS) SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. D. EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES CONCEALED IN WALLS AND CEILINGS. EMT SHALL BE MILD STEEL, ELECTRICALLY WELDED, ELECTRO—GALVANIZED OR HOT—DIPPED GALVANIZED AND PRODUCED TO ANSI SPECIFICATION C80.3, FEDERAL SPECIFICATION WW—C-563, AND SHALL BE UL LISTED. EMT SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND, OR APPROVED EQUAL. FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. E. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR FINAL CONNECTION TO EQUIPMENT. FITTINGS SHALL BE METALLIC GLAND TYPE COMPRESSION FITTINGS, MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED 6—FEET. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC. MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR UNIVERSAL METAL HOSE, OR APPROVED EQUAL. F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH (21 MM). HUBS AND BOXES: A. AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED. HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0—RING SEAL. PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION. B. CABLE TERMINATION FITTINGS FOR CONDUIT 1. CABLE TERMINATORS FOR RGS CONDUITS SHALL BE TYPE CRC BY 0—Z/GEDNEY OR EQUAL. 2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO — CL2075; OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE—HINDS WAB SERIES OR EQUAL. D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKETED COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION. PROVIDE CROUSE—HINDS FORM 8 OR EQUAL. E. MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN, SQUARE "D CROUSE—HINDS, COOPER, ADALET, APPLETON, 0—Z GEDNEY, RACO, OR APPROVED EQUAL. SUPPLEMENTAL GROUNDING SYSTEM A. FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM AS INDICATED ON THE DRAWINGS. SUPPORT SYSTEM WITH NON—MAGNETIC STAINLESS STEEL CLIPS WITH RUBBER GROMMETS. GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE, SIZES AS INDICATED ON THE DRAWINGS. PROVIDE STRANDED OR SOLID BARE OR INSULATED CONDUCTORS AS INDICATED. B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS, EXCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER; AT GROUND BARS USE TWO HOLE SPADES WITH NO OX. C. STOLEN GROUND—BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. EXISTING STRUCTURE: A. EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES, DEVICES, BOXES, AND OTHER EQUIPMENT THAT ARE NOT TO BE UTILIZED IN THE COMPLETED PROJECT SHALL BE REMOVED OR DE—ENERGIZED AND CAPPED IN THE WALL, CEILING, OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE. WALL, CEILING, OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION. CONDUIT AND CONDUCTOR INSTALLATION: A. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON—PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE. Sprint µ- 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 * I C-020876 I * \TF OF REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 1007. CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: OUTLINE SPECIFICATIONS SHEET NUMBER: T-3 BATTERY INFORMATION/ NOTES: BATTERY TYPE: RECOMBINANT BATTERIES, VALVE REGULATED TOTAL EXISTING ELECTROLYTE CONTAINED A. QUANTITIES OF 50 GALLONS OR LESS ARE EXEMPT PER ON SITE (2.17 X 16): 34.72 GALLONS/BATTERY CABINET, TABLE 3-E OF THE 2013 C.F.C. BATTERY MFG: ALCATEL-LUCENT/EAST PENN MANUFACTURING 34.72 GALLONS TOTAL B. SINGLE VESSEL CAPACITIES OF 10 GALLONS OR LESS, AND MODEL NUMBER: 12AVR-145ET TOTAL EXISTING ELECTROLYTE CONTAINED AGGREGATE QUANTITIES NOT IN EXCESS OF 100 GALLONS ELECTROLYTE CONTENT PER BATTERY: 2.17 GALLONS ON SITE TO REMAIN (2.17 X 16): 34.72 GALLONS ARE EXEMPT PER ARTICLE 64 OF THE 2013 C.F.C. INTOTAL PROPOSED ELECTROLYTE C. STATIONARY STORAGE BATTERY SYSTEMS HAVING AN ELECTROLYTE HAZARD CLASSIFICATION ELECTROLYTE CAPACITY OF MORE THAN 50 GALLONS FOR CASE OF PER '13 C.F.C. (8.7% SULFURIC ACID): CORROSIVE CONTAINED ON SITE (2.17 X 4): 8.68 GALLONS FLOODED LEAD -ACID, NICKEL CADMIUM AND VALVE TOTAL ELECTROLYTE CONTAINED REGULATED LEAD ACID, OR 1,000 POUNDS FOR LITHIUM -ION EMERGENCY AND LITHIUM METAL POLYMER, USED FOR FACILITY STANDBY ON SITE (2.17 X 20): 43.4 GALLONS MAX NUMBER OF EXISTING POWER, EMERGENCY POWER OR UNINTERRUPTED POWER BATTERIES: 16/BATTERY CABINET SUPPLIES SHALL COMPLY WITH SECTION 608 OF THE 2013 16 TOTAL CALIFORNIA FIRE CODE AND TABLE 608.1 OF THE 2013 NUMBER OF EXISTING CALIFORNIA FIRE CODE, CALL BATTERIES TO REMAIN: 16 BATTERIES D. ANY CHANGES OR ADDITIONS TO BACK-UP BATTERIES MUST NUMBER OF BATTERIES TO COMPLY WITH 2013 C.F.C. ARTICLE 64, AND SHALL NOT BE INSTALLED: 4 BATTERIES CONTAIN ELECTROLYTE QUANTITIES IN EXCESS OF 50, 1 8 6 6 4 0 0 6 04 0 NUMBER OF BATTERIES ~fig~ TOTA! : 20 BATTERIES s_ FIRE DEPARTMENT NOTES: SITE NUMBER: RV54XC504 1. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE INSPECTION 2 DAYS IN ADVANCE, SITE NAME: LA QUINTA RESORT 2. A CFC PERMIT TO OPERATE BATTERY SYSTEMS WITH STATIONARY LEAD -ACID BATTERIES IS NOT REQUIRED' FOR THE QUANTITIES ON SITE. 3. A CFC PERMIT MAY BE REQUIRED FOR THE HAZARDOUS MATERIALS ON SITE. REQUIRED NFPA SIGNAGE 4. A HAZARDOUS MATERIALS IDENTIFICATION SIGN IS REQUIRED FOR ALL ENTRANCES INTO BATTERY STORAGE AREAS. LETTERS MUST BE AT LEAST 1" IN HEIGHT AND IN A COLOR WHICH CONTRASTS TO THE BACKGROUND OF THE SIGN AND LIST THE FOLLOWING: GLASS 1 WATER REACTIVE LIQUID TOXIC LIQUID SITE IDENTIFICATION SIGNAGE 3 CORROSIVE LIQUID OTHER HEALTH HAZARD LIQUID 5. AN APPROVED METHOD FOR NEUTRALIZATION OF A SPILL IS ONLY REQUIRED FOR SYSTEMS HAVING MORE THAN 50 GALLONS OF ELECTROLYTES PER 2013 CFC 608.1. 6. BATTERIES SHALL BE PROVIDED WITH SAFETY VENTING CAPS. 7. LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WITH THE UNIFORM FIRE CODE STANDARD 10-1 AND PLACEMENT IS SUBJECT TO APPROVAL OF THE INSPECTOR. 8. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE AND COMPRESSED GASES, AND OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH UNIFORM FIRE CODE j REGULATIONS. j 9. EXIT DOORS SHALL BE ABLE TO OPEN FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL « KNOWLEDGE OR EFFORT. i 10. ADDRESS NUMBERS SHALL BE A MINIMUM 6 INCHES HIGH AND PLAINLY VISIBLE FROM ROADWAY BUILDING IS ADDRESSED ON. � I HAZARDOUS I' 11. REQUIRED SIGNAGE SHALL INCLUDE LETTERING HEIGHT OF AT LEAST ONE INCH, IN A COLOR THAT CONTRASTS TO THE SIGN BACKGROUND, AND SHALL BE PROMINENTLY DISPLAYED. MATERIAL Wii i 12. REQUIRED SIGNAGE SHALL INCLUDE BUT MAY IJOi BE. L'llJdl'EiJ TO,�li"2'L'f;r,Ju Ti'i'=== 7--r_)-)-7--r_)-)-E"^-1d.?�_r= / SHOWN HEREIN; SEE DETAILS 1, 2, AND 3. ni p e *ve ! STORAGE AREA Corros HAZARDOUS MATERIAL SIGNAGE 2 ACAU"ThON Beyond this point; Beyond tole paint, l�aldlo trequeney fields beyond 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 G D AR%- .� * I C-020876 J* � SEB. 2 " �� REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY Ri frequency fields at this siteRadio frequency fleids at tills slut SHEET TITLE: iitils palrlt ma exceed. tMe FCS may exceed FCC rules flor human Y exceed the FCC rules torr human exposure. general public exposure ilrniL exposures Far your solely; obey all posted signs and i boy Foilure to obey all posted signs and site tar working In rad Io tnrquency oto guldellfie+r !di i4�rrliiito 1i} rati18 environments. QUid#NrFox for working tit ro13iO ffitltlMGj�' I tequency tntvironmnt es, envitonnurds Could result irk serious injury. LBATTERY INFORMATION 4 RF SIGNAGE SIGNAGE & BATTERY INFORMATION SHEET NUMBER: T-4 gild � yea,. swin k 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 ED A T ,ct�Y �Fc� * I C-020876 I * \F CF CALIF REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914—A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: SHEET NUMBER: SITE PLAN A-1 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 pa'= -TAI 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 G�D ARCjyT� * I C-020876 I * �F OF CAUV/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 1007. CDS JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: NOTES: N 1. ROUTING SHOWN FOR GRAPHIC PURPOSES ONLY. N 2. ALL NEW CONDUIT TO BE INSTALLED TO AVOID TRIP HAZARDS. EXISTING EQUIPMENT PLAN 11X17 SCALE: 1/4°'=,'-o" 2 PROPOSED EQUIPMENT PLAN 11X17 SCALE: 1/4"=,'-0" 2X34 SCALE: 1/2"=1'-0" 0 1' 2' 4' 22X34 SCALE: 1/2"=1'-0" 0 1' 2' 4' EQUIPMENT PLAN SHEET NUMBER: A-2 N (E) iDEN zt (E) NV (E) NV r i I\ (E) iDEN (N) 2.5 / (E) iDEN / _ EXISTING VACANT MOUNTING PIPE (TYP.). EXISTING f65'-0" MONOPALM. /", - G 0" MONOPALM. EXISTIN t65 - EXISTING SPRINT iDEN ANTENNA, E3 :! (9) TOTAL TO BE REMOVED. PROPOSED (3) SPRINT 2.5 ! (E) iDEN ' RRH'S (1 PER SECTOR, 3 SECTORS) MOUNTED IND (E) iDENPROPOSED SPRINT 2.5 BEHIND ANTENNAS; SEE DETAIL 3/A-5. - -_ -- -- - PROPOSED (3) SPRINT 2.5 (_ - ANTENNAS (1 PER SECTOR, 3 E) NV (E) !DEN (E) NV (N) 2.5 2.5 SECTOR '2» SECTORS) MOUNTED ON (E) MEN / (N) 2.5 100• _ EXISTING MONOPALM; SEE DETAIL 2/A-5. EXISTING (3) SPRINT RRH'S — — EXISTING (3) SPRINT RRH'S MOUNTED BEHIND EXISTING \ MOUNTED BEHIND EXISTING NV SRCTO ANTENNAS TO REMAIN (1 PER NV SECTOR ..2„ ANTENNAS (1 PER SECTOR, 3 iDE.NI (E) NV R "2" (E) NV 100' SECTORS). SECTOR, 3 SECTORS). ) EXISTING (3) SPRINT NV i� �� EXISTING (3) SPRINT NV ANTENNAS TO REMAIN (1 PER v ANTENNAS (1 PER SECTOR, 3 SECTOR, 3 SECTORS). J \' SECTORS). F V0 M Uc0 W 00 LL] L U)O > o z z w 00 (E) !DEN N LO Ci N NOTE: N THE ANTENNA EDGE DISTANCE BETWEEN A 2.50 ANTENNA & 1.9G ANTENNA IS z 18". THE ,ANTENNA EDGE DISTANCE BETWEEN A 2.5G ANTENNA & 800M ANTENNA IS >- 30". THE ANTENNA EDGE DISTANCE BETWEEN A 1.9G ANTENNA & 800M ANTENNA IS z 18". THE ANTENNA EDGE DISTANCE BETWEEN A 2.5G ANTENNA & DUAL BAND 1.9G & 800M ANTENNA IS 30". 11X17 SCALE: ,/4" -Ott =,'2 PROPOSED ANTENNA PLAN 11X17 SCALE: 1/4"=,'-o" EXISTING ANTENNA PLAN 22X34 SCALE: 1/2"=1'-0" 0 1' 2' 4' 22X34 SCALE: 1/2"=1'-0" 0 1' 2' 4' 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 0 ARq�T ERfY L R Fir * C-020876 �A o` FEB. 7: �t 9TF A�' CAU REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: ANTENNA PLAN SHEET NUMBER: A-3 0 0 a m s D z M 0 a o: TOP OF EXISTING MONOPALM FRONDS. TOP OF EXISTING MONOPALM FRONDS. v� `f ±75.00 A.G.L. ±75.00 A.G.L. 1 Ali `v��ro w r i/iii y �% 1 PROPOSED (3) SPRINT 2.5 TOP OF EXISTING MONOPALM. 4"f.rx TOP OF EXISTING MONOPALM. ; 65.00 A.G.L. \ RRH S (1 PER SECTOR, 3 65.00 A.G.L. r fr SECTORS) M IND TOP OF EXISTING SPRINT ANTENNAS. PROPOSED SPRNNTD2 BEHIND TOP OF EXISTING SPRINT ANTENNAS. ANTENNAS . v < 64.00 A.G.L. 64.00 A.G.L. fr r �' �- EXISTING SPRINT iDEN EXISTING SPRINT NETWORK CENTER OF EXISTING SPRINT ANTENNAS. _ ' r ; ANTENNAS TO BE CENTER OF EXISTING & PROPOSED SPRINT ANTENNAS. _ _ _ _ _ VISION ANTENNA (TYP. OF 61.00 A.G.L. REMOVED. 1 PER SECTOR). _ _ e EXISTING SPRINT RRH'S -' I EXISTING SPRINT RRH'S MOUNTED BEHIND EXISTING E MOUNTED BEHIND EXISTING ANTENNAS (TYP. OF 1 PER == ANTENNAS (TYP. OF 1 PER �.: SECTOR). - ,.: SECTOR). EXISTING SPRINT NETWORK l' ANTENNAS,PROPOSED NAS(3) TPRIONT 2.5 = VISION ANTENNA (TYP. OF �' MATCH EXISTING 1 PER - = 1 PER SECTOR). SECTOR, 3 SECTORS). _ EXISTING HYBRIFLEX CABLES ROUTED INSIDE PROPOSED FIBER CABLE TO Y MONOPALM. FOLLOW EXISTING SPRINT CABLE ROUTE, }x EXISTING MONOPALM._ EXISTING MONOPALM. =_. o EXISTING SPRINT O EXISTING SPRINT EQUIPMENT ENCLOSURE. I EQUIPMENT ENCLOSURE. .n O .k"�.;. I't�^ ^V•'�'� - # a1.1-�t"p- >-{�-vf"31-t9'- ""f « � \ `�\ I 'tl`"�'"H I, 1 � _ i"l, j4'tl"I•' I;_"Fi"�"�4"i1- I 4?"I�''t'�•P_ _:r �:-". ".,/r ,� 1'}� ri�"i•f?k ��" I' " 1. r -:r \�a '}v-}d'fd"{+'?i-+{-�-1r-�b-�•Y'cr'i�! . lr-i4-w wm p! �! � in O # 1 y gy+yy5p �1..�+yryp y yi II-�)s _.k #f,• .I 'F1 '1 " .[ii '" " r. i. I I 1!! I J 1 I t I i. I 1 1 ,1 •.; ••iRi`A"V. x.. - 4 1 'I '1� . O (O I `<I'I �Pl t>\ I � I�: O I � / — — — — _ _ ... .. 11511 I I'1 11 li 1 r�✓%I{:'i _ '_ II It 0 pq P�lAl11�� ]IEEE] FEEIM EHE EIEH jj 14,r� 1 Ii i TOP OF F.S. Ilk TOP OF F.S. 0.00 A.G.L. 0.00 A.G.L. EXISTING NORTH ELEVATION 11x17 SCALE: 1/32,_10-0910 11x17 SCALE: 1/32»=1;-0" 24x36 SCALE: 1/16"=10 4 8 16 32,12 PROPOSED NORTH ELEVATION 24x36 SCALE: 1/16 —1 —0 0 4 8 16 32 7� 41 qSf 3 . sup-mrint d (y 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 ,GREY L.,a,Fci� * I C-020876 I * \TF OF CAUW/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CDS JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914—A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: ELEVATIONS SHEET NUMBER: A-4 0 0 a w M M ZD z M 0 p r M 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 A 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 * I C-020876 I * �ql FFB. 2n ��3 �F OF CAUL/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW APXV9TM14-C-120 B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE MANUFACTURER: RFS 60 (00 NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET ® 60 90 ANTENNA COLOR: LIGHT GREY RAL7035 PROPOSED 2.5 ANTENNA. DIMENSIONS, HxWxD: 56.3" X 12.6" X 6.3" PROPOSED ANTENNA DOWNTILT �® ANTENNA WEIGHT (W/OUT MOUNTING HARDWARE): 55.1 LBS PLAN VIEW MOUNTING BRACKET KIT. � MOUNTING HARDWARE WEIGHT: 11.5 LBS ®� TOTAL WEIGHT: 66.6 LBS 12.6" 6.3" PIPE TRANSFER KIT, PROVIDED ® m, ®o® a PROPOSED 2.5 RRH. CONNECTOR: (8) 4.1/9.5 DIN FEMALE BY MANUFACTURER. ®®--m ®� ®� (1) NF—CALIBRATION PORT a' MAIN SUPPORT BRACKET PROPOSED SCHEDULE 40 GALVANIZED a� ALCATEL—LUCENT OR APPROVED EQUAL. 3"0 STD. MOUNTING PIPE. UTILIZE ° EXISTING PIPE IF AVAILABLE. MAST MOUNTING BRACKET ALCATEL—LUCENT OR APPROVED EQUAL, (2) PER RRH. h PROPOSED SCHEDULE 40 `6 LO GALVANIZED 3"0 STD. MOUNTING PIPE. UTILIZE �® EXISTING PIPE IF AVAILABLE. SHARED OR SEPARATE MOUNTING PIPE. REFER TO STRUCTURAANALYSIS FOR ADDTIIONALLINFORMATION. m m ffi® FRONT VIEW SIDE VIEW DETAIL SCALE: 6 2.5 RRH DETAIL 2.5 ANTENNA DETAIL SCALE: 2.5 ANTENNA NONE SC. ONE NONE TD-RRH8X20-25 NOTDA L IS REFERENCE ONLY. PROPOSED SPRINT 2.5 ANTENNA; SEE DETAILS EXISTING CONDITIONS MAY DIFFER MANUFACTURER: ALU 2/A-5, 5/A-5, & 6/A-5. FROM DIAGRAM SHOWN. REFER TO PROPOSED DOWNTILT ANTENNA MOUNTING BRACKET STRUCTURAL ANALYSIS BY OTHERS. DIMENSIONS (W/ SOLAR SHIELD), HxWxD: 26.1 X 18.6 X 6.7 & HARDWARE BY ANTENNA MANUFACTURER. WEIGHT (W/ SOLAR SHIELD): 70 LBS PROPOSED ALU 2.5 RRH; SEE DETAIL 3/A-5, ®® _ 4/A-5, & 5/A-5. DIMENSIONS (W/OUT SOLAR SHIELD), HxWxD: 25.4" X 17.5" X 5.7" WEIGHT (W/OUT SOLAR SHIELD): 66.1 LBS a PROPOSED RRH MOUNTING BRACKET BY RRH PROPOSED SCHEDULE 40 MANUFACTURER. GALVANIZED 3"0 STD. MOUNTING PIPE. UTILIZE - EXISTING PIPE IF AVAILABLE. PROPOSED ANTENNA DOWNTILT MOUNTING BRACKET KIT. O O o F616 n < PROPOSED 2.5 ANTENNA. D PROPOSED FIBER CABLE. BOTTOM VIEW x � it PROPOSED 2.5 RRH MOUNTING BRACKET. TOP VIEW „ 18.6 " I. 6 7 -- w N cn EXISTING ANTENNA FRAME. a PROPOSED HEX BOLTS. a � I PROPOSED SCHEDULE 40 GALVANIZED 3"0 STD. MOUNTING PIPE, UTILIZE EXISTING PIPE IF AVAILABLE. PROPOSED ANTENNA j �� r MOUNTING BRACKET KIT. I'hy PROPOSED 2.5 RRH. I PROPOSED ANTENNA MOUNTING KIT BY ANTENNA O MANUFACTURER. N PROPOSED JUMPER CABLES FROM RRH TO ANTENNA. BOTTOM VIEW T `a PROPOSED JUMPER CONNECTION. _ Q O FRONT VIEW SIDE VIEW BASIC ASSEMBLY DETAIL SCALE: 5 2.5 RRH DETAIL 3 ANTENNA & RRH MOUNT DETAIL SCALE: NONE ONE NONE NONE p r M 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 A 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 * I C-020876 I * �ql FFB. 2n ��3 �F OF CAUL/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: ANTENNA & RRH DETAILS SHEET NUMBER: A-5 NOT USED x.2'17 B SQ r 52 CKA"EL FJT. G-ry ' 3 NSULATED FPC L • `'P«a Pui*tn= .'re tl mak$ aaban'� 1� ta�#p9 echanicai properties Electrical Properties DC-Resistantle OUWT Canciuctor Armor ItAm $i V1 00ft)j 1,'97 (0.60) Fiber Optic properties ROHS Compliant Environment % Thr. data �. provis�on4i jnd 5tah1cct io chs go, Please visit us on the Internet at http;tiwww.ffsworW.com Rev. P1 I Print Gate: 1.11.2013 ♦ r s CALE: SCALE: SNONE Z I FIBER CABLE SPECIFICATIONS NONE 1 94 qq�� �h3. 4ti ,54 � i t'01 4 sprif Ia C 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 * I C-020876 I * �F CF CAO REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: FIBER CABLE SPECIFICATIONS SHEET NUMBER: A-6 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 3 11111111110 IIIIIIIIIIIIIIII1110 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 ���RFY l�lF�i• * C-020876 fq �� �sp Ffa. \F OF CAUL/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK 60ECv2 BATTERY BACKUP UNIT CABINET 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE 2'-7" MANUFACTURER: ANDREW (COMMSCOPE) DIMENSIONS, HxWxD: 60" X 31" X 30" NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET WEIGHT (UNLOADED): 425 LBS MAX WEIGHT (W/ BATTERIES): 2,525 LBS TEMPERATURE RANGE: -40'C TO 46'C 0 o N TOP VIEW NOTE: LOCATION OF PROPOSED BATTERY STRINGS. o a o EXISTING BATTERY BACKUP UNIT CABINET. O o� O I O O FRONT VIEW BACK VIEW SIDE VIEW NOT USED SCALE: 4 EXISTING BATTERY BACKUP UNIT CABINET SCALE: NONE NONE NOTE: 9928 DISTRIBUTED BASE STATION 1. DETAIL IS DIAGRAMMATIC. SEE SITE PLAN FOR ACTUAL CABLE ROUTING MANUFACTURER: ALU AND LOCATION OF EQUIPMENT. DIMENSIONS, HxWxD: 76" X 35.4" X 37.8" MAX WEIGHT (HALF LOADED): 945 LBS MAX WEIGHT (FULLY LOADED): 1,074 LBS NOTE: 1. LOCATIONS SHOWN FOR INSTALLATION OF NEW EQUIPMENT IN EXISTING EQUIPMENT CABINET ARE APPROXIMATE. ACTUAL SPACE AVAILABLE TO BE PROPOSED 2.5 EQUIPMENT AND _ ____ ----- VERIFIED IN FIELD ON A SITE BY SITE BASIS. RECTIFIER UNIT TO BE INSTALLED IN EXISTING MMBTS CABINET. I" EXISTING ICE BRIDGE. PROVIDE 2" RIGID CONDUIT ----- PROV4DE PROPOSED SNAP -IN HANGER. CONNECTOR. • 99".9 PROVIDE 2" METALLIC HUB. - PROPOSED FIBER CABLE FOR 2.5 -_ I '. EQUIPMENT. f% EXISTING FIBER CABLE (TYP. OF 3). PROVIDE PROPOSED SNAP IN HANGER. El EXISTING 2" RIGID CONDUIT. b PROVIDE PROPOSED STANDOFF 28" BRACKET. PROPOSED 2.5 EQUIPMENT AND EXISTING FIBER BREAKOUT PROVIDE WATER -TIGHT CABLE / RECTIFIER UNIT TO BE INSTALLED ILL--- J BOX. CONNECTOR WITH RIGID CONDUIT IN EXISTING MMBTS CABINET. COUPLING. PROVIDE 2" RIGID CONDUIT. PROVIDE CONDUIT SUPPORT. - - -" - - - r-------- -i SUPPORT PER NEC CODE. I PROPOSED 2.5 EQUIPMENT IN EXISTING MMBTS CABINET INCLUDING -..-- 00CELL BUT NOT LIMITED TO BASE BAND UNIT, SITE ROUTER AND SURGE i I I ARRESTORS. POWER AND FIBER TO BE O I I I CONNECTED. I PLATFORM/CONCRETE PAD I PROPOSED RECTIFIER UNIT IN EXISTING L ---------J MMBTS CABINET. 37.8" SIDE VIEW 35.4" TOP VIEW CABLE ROUTE FROM CABINET SCALE:3 EX I STING M M BTS CABINET SCALE: NONE NONE 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 3 11111111110 IIIIIIIIIIIIIIII1110 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 ���RFY l�lF�i• * C-020876 fq �� �sp Ffa. \F OF CAUL/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: • 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 p3m 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 ARq�l\ * C-020876 fo �� \rf OF CAU�� REVISIONS REV. DATE DESCRIPTION NOTE: NOTE: 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S CONTRACTOR TO USE MECHANICAL CONNECTION PROPOSED FIBER CABLE TO BE BONDED TO #4 OR #6 AWG SOLID CU FOR GROUNDING OF RRH AND CADWELD EXISTING SECTOR GROUND BAR. CONDUCTOR WITH GREEN, NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET CONNECTION FOR GROUNDING OF ANTENNA 600V THWN-2 INSULATION. KOPR SHIELD. PIPE MOUNT. ANTENNA SECTOR (TYP.) ® ® O PROPOSED SPRINT 2.5 ANTENNA ������� EXISTING GROUND NOTE: li & RRH UNIT (TYP. PER SECTOR). BAR. EXISTING RRH & RRH l PROPOSED #6 AWG STRANDED GROUNDING NOT SHOWN. WITH GREEN, 600 V, THWN-2 Ii INSULATION FOR 2.5 ANTENNA TO - - - - (` COAX JUMPERS. EXISTING SECTOR GROUND BUS. EXISTING CADWELD. TO EXISTING GROUNDING SOURCE. r-------� I - - - - - - - - - ----J FLAT WASHERS ON BOTH SIDES EXISTING SPRINT SECTORq� 000n°°"� OF BUS BAR. GROUND BAR TO BE UTILIZED OHOLE SPADE TO BE USED (TYP. OF 1 PER SECTOR). _ _ _ - - - - - - - - - - TOCONNECTTOGROUND BAR. PROPOSED #6 AWG STRANDED a RRH WITH GREEN, 600 V, THWN-2 INSULATION FOR FIBER BREAKOUT UNIT TO SECTOR GROUND BAR. z PROPOSED (2) #6 AWG N ~STRANDED NX N WITH GREEN, 600 V, bi Q THWN-2 INSULATION FOR 2.5 NOTE: a o RRH TO EXISTING GROUND BAR. ALL CONDUCTORS SHALL BE #6 (o CL AWG SOLID TINNED UNLESS 1. APPLY NO—OX TO LUG AND GROUND BAR CONTACT OTHERWISE NOTED. SURFACE. DO NOT COAT INLINE LUG. EXIST. CGB 2. IF STOLEN GROUND BARS ARE ENCOUNTERED, CONTACT SPRINT CM FOR REPLACEMENT THREADED ROD KIT. GROUNDING PLAN SCALE: 4GROUNDING CONDUCTOR INSTALLATION SCALE: ANTENNA NONE NONE DC/FIBER NOTE: EXISTING ALU EXISTING ANDREW PROPOSED FIBER CABLE TO BE BONDED TO MMBTS CABINET BATTERY CABINET GROUND BAR IN PROPOSED GROWTH CABINET. GROUND PROPOSED 2.5 EQUIPMENT AND RECTIFIER UNIT TO EXISTING MMBTS GROUND BAR. ------ I EXISTING MMBTS GROUND-----\— ---J I INSPECTION WINDOW BAR TO BE UTILIZED. REQUIRED FOR ALL INTERIOR TWO—HOLE 1" 1/4 j CONNECTORS. BUTT CONDUCTOR MIN. MIN. -- --- EXISTING SPRINT MMBTS CABINET. EXTERNAL TOOTHED. INSULATION UP AGAINST THE MGB CGB _ 3/8 �bx1 1/2'. CONNECTOR BARREL 0 0 0 S/S NUT. --- CLEAR #2 AWG STRANDED GROUNDING _ —_ S/S LOCK WASHER. _ HEAT 3 '' CONDUCTOR FROM MMBTS GROUND I S / S FLAT WASHER. SHRINK a —'' BUS TO MAIN GROUND BAR. FIELD I I — — — — - N #6 AWG FROM VERIFY LOCATION. GROUND KITS TINNED COPPER ( I APPLY NO -OX. GROUNDING BAR. EXISTING SPRINT MMBTS GROUND I I oo NOT EXISTING GROUND BAR IN EXISTING MMBTS CABINET TO I I TINNED COPPER COLD SHRINK OR DISCONNECT TO GROUND RING -- - BE UTILIZED. I I GROUNDING BAR. APPROVED EQUAL. EXISTING CABINET GROUNDING (TYP) S/S FLAT WASHER. DO NOT DISCONNECT' --------------- S/S BOLT (1 OF 2). TAG ON ALL GROUNDING BAR INTERCONNECTS AND EQUALIZERS. PROPOSED 2.5 EQUIPMENT AND RECTIFIER UNIT TO BE INSTALLED IN EXISTING MMBTS CABINET. LEGEN ■ CADWELD CONNECTION MECHANICAL CONNECTION • COMPRESSION CONNECTION SCALE: 5 EQUIPMENT GROUNDING PLAN SCALENONE TWO HOLE LUG SCALE GROUNDING RISER DIAGRAM NONE. NONE • 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 p3m 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 ARq�l\ * C-020876 fo �� \rf OF CAU�� REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914-A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: GROUNDING DETAILS SHEET NUMBER: E-1 0 W In z DID 0 a CIRCUIT SCHEDULE NO FROM TO CONFIGURATION OUTILITY SOURCE METER/DISCONNECT EXISTING O METER/DISCONNECT TRANSFER & EXISTING C 06/16/14 LOAD CENTER JE O TRANSFER & GENERATOR EXISTING LOAD CENTER RECEPTACLE O TRANSFER & EXISTING BATTERY BACKUP UNIT (2) #12 AWG, (1) #12 GND IN LOAD CENTER CABINET 3/4" CONDUIT NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET )#8 O TRANSFER & EXISTING MMBTS 1 GNDGIN (() LOAD CENTER CABINET 1-1/2" CONDUIT EXISTING DC — (I� PROPOSED (3) DC POWER TO N.V. POWER TO 2.5 RRH'S. I RRH'S. INSTALL (3) RRH'S. ( f - I 3 Lilt 2.5 RRH 2.5 RRH 2.5 RRN - , r' EXISTING N . DC EXISTING 200A EXISTING 200A — - - -- BUS BAR. METER/DISCONNECT GENERATOR li �� �� ®®® SWITCH. RECEPTACLE. ® ® ® CONDUCTOR SIZE. J TO EXISTING 200A UTILITY POWER SOURCE. PD SURGE ARRESTORS INSIDE - PD SPD S PROPOSED GROWTH CABINET, (4� N 2 3 EXISTING BATTERY EXISTING MMBTS�� BACKUP UNIT CABINET CABINET CONDUCTOR SIZE. ( CIRCUIT BREAKER SIZE. EXISTING 200A SPRINT EXISTING SERVICE F-------- PPC/AC PANEL. -i `--- --! GROUND. — — — — — — — J OA 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20 200A 2o0A � --- - -- � - -- - � INSTALL PROPOSED 2.5 EXISTING BUS �� i _/ i'� BAR KE CIRCUIT EQUIPMENT & RECTIFIER PROPOSED (3) BREAKERS. CIRCUIT BREAKERS IN EXISTING MMBTS FOR RRH'S. CABINET. nn r-------- �� TO EXISTING LOADS (REFER L -------J TO PANEL SCHEDULE). TO EXISTING LOADS 15A (REFER TO PANEL 2P 4 SCHEDULE). 00 2P 5 NOTE: FIELD VERIFY EXACT LOCATION OF OPEN BREAKERS. SCALE: SCALE: SCALE: ELECTRICAL ONE -LINE DIAGRAM NONE 4 DC ONE -LINE DIAGRAM NONE 3 DC BREAKER DETAIL NONE 2 I i 330 COMMERCE, SUITE 100 IRVINE, CALIFORNIA 92602 980 ROOSEVELT, SUITE 210 IRVINE, CALIFORNIA 92618 Jeffrey Rome I ASSOCIATES architecture I telecommunications 131 Innovation Drive; Suite 100 Irvine, California 92617 tel 949.760.3929 1 fax 949.760.3931 G.., fc D ARq�lc * I C-020876 I * s?ql FFB. 2 " #t �FCF CAL1V/ REVISIONS REV. DATE DESCRIPTION INIT. A 05/02/14 90% CD REVIEW IK B 05/28/14 100% CD'S JE C 06/16/14 REVISED 100% CD'S JE NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SITE INFORMATION: 2.5 EQUIPMENT DEPLOYMENT RV54XC504 SBA SITE: CA45914—A-01 LA QUINTA RESORT 49-499 EISENHOWER DRIVE LA QUINTA, CALIFORNIA 92253 RIVERSIDE COUNTY SHEET TITLE: DC POWER DETAILS SHEET NUMBER: SCALE: NOT USED NONE E-2 r` 0 0 a Ld W M M z m 0