Loading...
SA 2005-876 Centre at La Quinta (SAM's Club)COMPREHENSIVE SIGN PROGRAM Store No. 4941: La Quinta, CA March 28, 2005 ening Commission �--- City Council r �•--�.. qLpcMmunity Dev. Dept Initials �' S,,, Case No. Exhibit ❑ With Conditions IWOIkncmwo9� 9 p kN691].68011 P. ]691I.6EOB vmw.wl+ldccom 49d1jMP005020 Project Directory 2 Purpose & Intent 3 General Provisions & Specifications 4 Construction Specifications & Miscellaneous Requirements 5 Site Plan 6 Sign M-1 7 Sign M-2 8 Sam's Club Elevations 9-11 Sam's Club Fuel Station Elevations 12-13 Signage Detail 14 Installation Detail 15 I TABLE OF CONTENTS s0pp lakes dnre. sude JUS sresl cuNna, ra 9119U y 6t691].� www.wp]dcmm Signage Architect: WPIIDC, Inc. Contact: Howard Hardin 1000 Lakes Drive, Suite 405 West Covina, CA 91790 Phone: 626.917.6800 Fax: 626.917.6808 Civil Engineer: Nasland Engineering Contact: Michael Birkland 4740 Ruffner Street San Diego, CA 92111 Phone: 858.292.7770 Fax: 858.571.3241 2 PROJECT DIRECTORY 11100 Lkas dmm��uila Yli vrc�f cwlnym 91A0 1�41491)LWO 1-614.91]bm3 wnvup2dcr.ml PURPOSE AND INTENT To promote the quality of design desired for this Retail Project, this Sign Program establishes criteria for the design, implementation and regulation of Sam's Club signage as well as site or thematic graphics for the Sam's Club located in La Quinta, California. Signage of high quality design and materials using appropriate colors is considered an integral part of the image and success of this Retail Project. The Sam's Club may utilize any or all of the sign types described herein except as specifically modified in this Sign Program. All signage shall comply with applicable provisions of the Zoning Ordinance and land use plans of the City of La Quinta. All building and site signage shall be consistent with this Sign Program to provide a consistent and comprehensive design character. The intent of this Sign Program is to ensure that signage for Sam's Club is designed and executed in a manner which will achieve the following objectives while providing desired project identification. Exterior Signing The objectives of exterior signage are: • To provide concise identity and information for shoppers and prospective shoppers while avoiding visual competition with the building's aesthetic or the site landscaping. • To produce creative signage in good taste that will enhance Sam's Club's image while complementing the architectural and landscape design theme. • To provide functional signage to effectively serve the needs of consumers while providing proper identification of Sam's Club. • To expedite the review and approval of the Retail Project's signage by providing guidelines and criteria that explain acceptable standards for the signage. wliA,�nnn �ailc m 91TM 1 r V 463691]UWe w�QA�. No sign shall be installed without the approval of this Sign Program by the City of La Quinta. • Signs shall meet or exceed minimum industry standards for graphic quality and shall be designed to be compatible with and complementary to the surrounding building facades. Sign fabrication work shall meet or exceed minimum industry standards for quality. • The sign copy, color, size and design shall be consistent with this Sign Program, which shall be subject to approval by the City of La Quinta. Letter heights and logos, where specified, shall be determined by measuring the outer perimeter of the sign, inclusive of all letters inclusive of swasher, ascenders, and decenders. • Wall signs shall be affixed without visible means of attachment, unless attachments make an intentional design statement and are an integral part of the design. • Sam's Club's sign contractor shall repair any damage to the building caused by its work. 4 GENERAL PROVISIONS AND SPECIFICATIONS IOOI�IaMi�dn�r =u�la� w.z w 91)wl I c V LR691I451MI • All identification signs and secondary identification signs shall consist of face -illuminated individual dimensional letter forms and/or symbols (or an assembly of dimensional letter forms where the Retail Project's logotype is script - style letters). All letter/symbol faces shall be translucent acrylic with integral color. • The cabinet and/or channel letters shall be constructed of 0.060 - 0.090 aluminum with 1/8" plastic face and fastened to the wall or fascia in an approved manner. All metal shall receive a minimum of two (2) coats of primer and two (2) coats of finish paint. Metal sheet seam joints shall be joined by pop rivets. Halo lighting and/or neon need secondary ground fault consistent with UL2161. All letters shall have service access to lamps, ballasts and wiring. • All fascia signs shall be centered left to right on the fascia or building frontage and generally centered top and bottom between fascia reveals. The vertical position will vary depending on the configuration of the sign and the locations of the reveals on the sign fascia. • Power will be provided from the site and/or building electrical panel to a junction box at all sign locations. Power connection shall be Sam's Club's responsibility. A time clock shall be provided by Sam's Club to turn off power to its wall signs. All electrical signs shall bear the Underwriters Laboratory "UL" symbol (not visible to the public view), and the installation of all electrical signs shall comply with applicable building and electrical codes. The owner of the Sam's Club shall pay for electrical service for the signs. All conductors, transformers and other equipment shall be concealed. • All penetrations of the building structure required for sign installation shall be neatly sealed in a watertight condition. All bolts, fastenings, clips, etc. shall be painted to match the adjacent building surface. • All lettering shall be restricted to the "net sign area". No projection above or below the "net sign area" shall be permitted except as otherwise approved in writing. ■ Any hole or other building damage resulting from the removal of a sign shall be repaired and painted to match the building surface in the vicinity of the damage. ■ The owner of the Sam's Club shall maintain the Retail Project's signs in accordance with applicable City of La Quinta standards and shall replace defective lights and components in a timely manner. • All sign installers shall comply with applicable State and local statutes, regulations and ordinances, and shall possess a current, valid City of La Quinta business license and shall provide evidence of a current, valid Workman's Compensation Insurance policy. 5 CONSTRUCTION SPECIFICATIONS & MISCELLANEOUS REQUIREMENTS ..,�wnrxa Wi Hwy 7 t l M-1 Monument Sign M-2 Monument Sign SITE PLAN SITE SIGNAGE M-1 Monument Sign S. ,4 - Sign Area per side: 9.00 SF Total number of signs on Monument: trvl 1— Arise xunr Mir svesl ro�v�6a691 �4BW ( 26 Y1�LSIH SITE SIGNAGE M-2 Monument Sign ra• f 4k -Y--- WE ARE IN BUSINESS FOR SMALLBUSINESS. f Sign Area per side: 45.00 SF 'Total number of signs on Monument: 2 N IUIq IaA�•z drne sui;r MK »as 9lhXr r c ^6+691] f 16 yt]wM »vwxpldr rum ILLUMINATED SIGN: Configuralion: Channel letters with vacuum formed face (pan -formed) anchored to building surface,. Internally illuminated with fluorescent tube or LED, Face: Constructed with Sunguard Weatherable Polycarbonate CQfor. Red - PMS 193C / White Mountinu: Anchor bolt/bracket - size to be submitted to jurisdiction for approval prior to installation. NON -ILLUMINATED SIGN: Confi_guiation: Plexiglas formed letters stud mounted to building surface. Face.• Constructed with Sta-Tuf Plastic Color: Blue - 286CVC / Orange - 166 CVC / Green - 583CVC / White MounrinQ: Threaded stud - size to be submitted to jurisdiction for approval prior to installation. Minimum 3 studs per sign. SIGN DIMENSION TOTAL SIGN DIMENSION TOTAL Sign A w 14'1 3/4" x 14'1 3/4"(2) 265.00 SF Sign D(N) 7'6" x 7' 6" 56.25 SF Sign B (N) 1' 6" x 3'6" (2) 10.50 SF Sign F m 3' 9" x 9' 2" (2) 68.80 SF Sign GN) 1' 6" x 814" 12.50 SF Sign Area Sub -Total: 413.05 SF (q -Illuminated Signs (N) - Non -illuminated Signs Total Building Sign Area: 562.87 SF (E) - Externally -Illuminated lomm North Elevation ► r' 9 ILLUMINATED SIGN: Configuration: Channel letters with vacuum formed face (pan -formed) anchored to building surface. Internally illuminated with fluorescent tube or LED. Face: Constructed with Sunguard Weatherable Polycarbonate Color. Red - PMS 193C / White Mounting: Anchor bolt/bracket - size to be submitted to jurisdiction for approval prior to installation. NON -ILLUMINATED SIGN: Configuration: Plexiglas formed letters stud mounted to building surface. Face: Constructed with Sta-Tuf Plastic Colo c Blue - 286CVC/ Orange- 166 CVC /Green - 583CVC /white Mounting: Threaded stud - size to be submitted to jurisdiction for approval prior to installation. Minimum 3 studs per sign. SIGN DIMENSION TOTAL Sign B (N) 1' 6" x 3'6" 5.25 SF Sign E (N) 1'6" x 24' 11" 37.38 SF (p - Illuminated Signs (N) - Non -illuminated Signs Sign Area Sub -Total: 42.63 SF Total Building Sign Area: 562.87 SF West Elevation Iu7 ILLUMINATED SIGN: Configuration: Channel letters with vacuum formed face (pan -formed) anchored to building surface. Internally illuminated with fluorescent tube or LED. Face: Constructed with Sunguard Weatherable Polycarbonate .o oC Red - PMS 193C / White Mountin": Anchor bolt/bracket - size to be submitted to jurisdiction for approval prior to installation. NON -ILLUMINATED SIGN: Configuration: Plexiglas formed letters stud mounted to building surface. Face. Constructed with Sta-Tuf Plastic Co/or: Blue - 286CVC / Orange - 166 CVC / Green - 583CVC / White Mounting Threaded stud - size to he submitted to jurisdiction for approval prior to installation. Minimum 3 studs per sign. SIGN DIMENSION TOTAL Sign H of 3' 1 /2" x 7'41/2" 22.43 SF Sign lul 11'33/4"x11'33/4" 84.76 SF (1) - Illuminated Signs (N) - Non -illuminated Signs (E) - Externally -Illuminated Signs Sign Area Sub -Total: 107.19 SF Total Building Sign Area: 562.87 SF East Elevation 11 ILLUMINATED SIGN: Conrigur tion: Channel letters with vacuum formed face (pan -formed) anchored to building surface. Internally illuminated with fluorescent tube or LED. Face: Constructed with Sunguard Weatherable Polycarbonate Color. White Mounting: Threaded stud - size to be submitted to jurisdiction for approval prior to installation. Minimum 3 studs per sign. SIGN DIMENSION TOTAL Sign G ul 2'0" x 21'2" 42.34 SF (1) - Illuminated Signs (N)- Non -illuminated Signs Sign Area Sub -Total: Total Building Sign Area: 42.34 SF 84.68 SF Fuel Station: East Elevation 12 I-- d1m'u.11- c fVLM26�/1]L:AO t k rcm ILLUMINATED SIGN: Configuration: Channel letters with vacuum formed face (pan -formed) anchored to building surface. Internally illuminated with fluorescent tube or LED. Face: Constructed with Sunguard Weatherable Polycarbonate .CQIQt White MOU17tinY: Threaded stud - size to be submitted to jurisdiction for approval prior to installation. Minimum 3 studs per sign. SAM'S CLUB Gas SIGN DIMENSION TOTAL Sign G (1) 2' 0" x 21' 2" 42.34 S.F. (1) - Illuminated Signs (N) - Non -illuminated Signs Sign Area Sub -Total Total Building Sign Area 42.34 SF 84.68 SF Fuel Station: South Elevation 13 WJ Iak N A�We surtr11�i wrs a 91N� -.w.wvxn�.om 34.40 SQ FT Sign F �xii -, ntranc 5.75 SQ 11 12.5 SQ FT Sign B Sign C Z-40 Sri FT Sign D 22.43 SQ FT Sign H iu' u 3 Sign A ?.50 SQ FT 26- 11 -.[fi-r—e—& Battery Installatio Sign E 42..3•. Sfl FT Sign G l G 84.74 SQ R Sign I 14 SIGNAGE DETAILS PRESSEOF Illuminated Signage Detail ATTACHED DETAIL NTS DING FASCIA IT FACE BLOCK OVERSIZED HOLE FILLED W/SILCONE ADHESIVE THREADEDSTUD Omngu Arrow CMU Budding Sy -,i Scan's 1/1 x4 Sleeve Anchor I/2 Flex Cmuluil 10' IwT WI'Pllcd m Icuoe s(.bh,-d through and cmdWI by sign iinlaller. 4' .4 I-Bnx sipphsd md u -11M by general su '-"a eh,data.' G—m Trssngles E I rS. nr mesal Budding S)ssem ;rH Plyuoml badung by Wildmg mmnrmr. Signanadwdsn Mnldnsg MMMS nainless sleet bulls aid wash— rmm and Ixuk Gin nn conal 61041% 6 mesal scads sn 114 O C ana�hsrl io gins on mesal building and mmimred w slab by building'.'— u_ 1/1 x4 SI—Asdww I,H.CaMun LI 40' bng ssspphed m I—, subbed d—gh as .ulkedbydp im Ilcr. 4^ x 4 1 -Brae supplied and i—IW by gnmral m YiMtors ale ascian SignaReSection onCMU N.T.S. SiSEMSectionOnELESorNW NTS. © Copyright 2005, WPI IDC, Inc. The information contained in this document is intended to be confidential as between this sender and the intended recipient. To the extent that you are not the intended recipient, please destroy this document and all copies thereof and kindly contact the sender to advise as to said action. Any unauthorized use, disclosure or distribution of this document is prohibited. Your cooperation is appreciated. Thank you. INSTALLATION DETAILS ILI Frm lakes dine <u - wrs ;= WEIGHTS AND MEASURES (1) The price per gallon or liter, including all taxes, in numerals, and fractions when applicable, not less than six inches in height,and of uniform size and color. For the purpose of this article, fractions are considered one numeral. (2) The trademark or brand of the motor fuel in letters, figures, or numerals not less than one-third the size of the numerals designating the price. (3) The word "gasoline" or the name of other motor fuel in letters not less than one- third the size of the numerals designating the price, but these words need not be more than four inches in height. (4) The grade designation of the motor fuel in letters or numerals not less than one- sixth the size of the numerals designating the price, but this designation need not be more than four inches in height. (5) If motor fuel prices are advertised by the liter, the word "liter" shall be displayed on the advertising medium in letters not less than one-third the size of the numerals designating the price. (b) (1) It is unlawful for any person to display an advertising medium which advertises a discount or price reduction for motor fuel, unless the advertising medium contains all the following: (A) The price per gallon or liter from which the discount or price reduction is to be taken. (B) The amount of the discount or price reduction in cents per gallon or liter using numerals which do not exceed the height of the numerals in the advertised price. (C) The conditions of the discount or price reduction using words whose letters are not less than one-third the size of the price numerals. (2) Any limitations under which the discount or price reduction is offered shall be explained in words whose letters are not less than one-third the size of the numerals indicating the prices. (3) There shall be available for each customer's reference, a chart showing the amount of discount for each type unit being sold (gallon/liter) or fraction thereof in one cent ($0.01) increments, or the retail dispensers used to dispense fuel at the discount price shall be set to compute the total sale at the discounted price per gallon or liter and shall be clearly labeled "Includes Cash Discount" in letters not less than one inch in height. 146