Loading...
SA 2008-1281 Madison SquarejWad'tson Square o APPROVED BY PLANNING COMMISSION ON ` BY e DATE /I 'k !� RESO CASE NO, DEVELOPER: Highway 111 Partners, LLC. c/o Sobel Enterprises, Inc. 420 S. Beverly Dr. Suite 200 Beverly Hills, CA 90212 Ph. (310) 277-4697 MM - 776� W IN Master Sign Program ARCHITECT: Prest-Vuksic Architects 44-530 San Pablo Ave. Ste. 200 Palm Desert, CA 92260 Ph: 760.779.5393 10-14-08 SIGN CONSULTANT: AD ART SIGN CO. 2321 Rosecrans Ave. Suite 1250 EI Segundo, Ca. 90245 Ph. (310) 297-9777 a"F a- CMN COMPANY OCT 21 2008 CITY OF LA OI;INTA PI ►a IvIVIIVCx i3rPAt� I"IUfENT—J wvil-*d �1 LSA J. SPECIFICATIONS (Part 1) S.1 SPECIFICATIONS (Part 1) S.2 TENANT LAYOUT SPECIFICATIONS S.3 TYPE & COLOR SCHEDULE. S.4 PLOT/SITE SIGN SCHEDULE (Buildings 1 thru 6) R1 BUILDING 1 -APPROVED SIGN LOCATIONS E-1 BUILDING 2 -APPROVED SIGN LOCATIONS E-2 BUILDING 3 -APPROVED SIGN LOCATIONS E-3 BUILDING 4 & 5 -APPROVED SIGN LOCATIONS E-4 &5 BUILDING 6 -APPROVED SIGN LOCATIONS E-6 M PROJECT MONUMENTS 1.1 W -A TENANT WINDOW ADDRESSES (SPACE I.D.'S) 1.2 TENANT SIGNS TS -1 TENANT SIGN LAYOUTS (Bldg. 1) 2.1 TS -2 TENANT SIGN LAYOUTS (Bldg. 2, 4 & 5) 2.2 TS -3 TENANT SIGN LAYOUTS (Bldg. 3) 2.3 TS -6 TENANT SIGN LAYOUTS (Bldg. 6) 2.4 CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. SIGN I DESIGN INTENT The purpose of this Master Sign Program is to provide a consistent and harmonious criteria throughout this project. Also to provide uniform standards for all current and future Tenants within Madison Square as the Uniform Building Code and the City of La Quinta 's Sign Criteria. APPROVALS All signage must have written approval from Landlord , or it's designee, and the City of La Quinta before construction. Before submitting to the City of La Quinta , eligible applicants must first submit (3) three copies of the following to Landlord or their designee; 1. Dimensioned Site Plan showing proposed sign locations and signband heights and widths (subject to verification). 2. Scaled Elevation Drawings showing proposed sign locations, height to finished grade and placement upon wall (left to right & top to bottom measurements). 3. Sign Construction Details illustrating finish & colors, logo & letter sizes, electrical details and method of attachment. 4. Landlord shall determine and approve the availability and position of a Tenant name on any ground sign(s).and need to be illustrated on submittal. EXCEPTIONS Exceptions to these standards shall not be permitted without approval from the Landlord and will require approval of a modification to the sign program application by the City of La Quinta's Planning Director. If the applicant and Planning Director cannot come to a determination, Planning Commission review and approval will be required. CONFLICTS wI DRAWINGS OR CONDITIONS Any conflicts or contradictions either in regards to these drawings or as they relate to other disciplines or contractors shall be described in writing to Landlord, or it's designee, along with any possible solutions. All conflicts are to be resolved and any changes approved by Landlord, or it's designee, prior to sign construction and installation. COMPLIANCE REQUIREMENTS No Tenant or it's agents shall erect, reinstall, construct, enlarge, move, remove, change or equip any sign structure contrary to, or in violation of, this Master Sign Program. Conformance will be strictly enforced by Landlord, or their designee, along with the City of La Quinta 's Planning Department. Any nonconformance or unapproved signs will be the responsibility of Tenant to correct within a period not to exceed (30) thirty days at Tenant's own expense. MAINTENANCE Signs located within Madison Square shall be maintained in an "As New Condition". Landlord will periodically perform a visible sign inspection looking for but not limited to the following; 1. Material Fading, Cracking and/or Peeling. 2. Improper Illumination 3. Any Damage Caused by Human or Nature Any said damage repair will be the responsibility of the end user. DESIGN STANDARDS Details on these drawings represent the design approach for sign structures but do not necessarily include all fabricating details. It shall be the responsibility of Tenant and it's contractor to incorporate all reasonable safety factors necessary to protect Landlord, or it's designee, against public liability. DETAILS 1. All "Hard" sign construction shall be fabricated of pre -finished .063 alum. returns. Corner joints to be filled and/or ground smooth. 2. Sign exterior painting will consist of Matthews paint products or comparable variant as per client color specifications; a. One (1) coat of 74-734 Metal Pre -treat b. One (1) coat of 74-793 Spray Bond c. One (1) coat of Polyurethane Acrylic 3. Signs to be internally illuminated will utilize Title 24 compliment Low voltage LEDs as per Tenant color specifications. 4. Sign faces will consist of acrylic. 5. All mounting hardware will be stainless steel to avoid rust & wall penetrations are to be sealed against weather elements 6. All Tenants are allowed signs in designated areas of individually mounted logo & letters within allowed height per location unless otherwise stated in this criteria. 7. Should a sign be removed, it is the Tenant's responsibility to patch all holes, paint surface to match the existing color, and restore surface to original condition. 8. Any Tenant sign left after thirty (30) days from vacating premises shall become the property of the Landlord. CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. PROHIBITED SIGNS 1. Pole signs and other signs with exposed structural supports not intended as a design element, except for code -required signs. 2. Windowed signs that are attached to the interior or exterior of any glass or glazing visible from the exterior of the building, except for building wall sign types specifically permitted by this sign program. 3. Pre -manufactured signs, such as franchise signs, that do not meet or have been modified to meet this sign program. 4. Face illuminated logos and/or letters (halo only). 5. Cabinet signs of any type (i.e. face illuminated, routed out nor push-thru acrylic). 6. Internally illuminated / backlit awnings. 7. Exposed neon lettering nor borders. 8. Signs constituting a Traffic Hazard. No person shall install or maintain, or cause to be installed or maintained, any sign which simulates or imitates in size, color, lettering or design any traffic sign or signal, or which makes use of the words "STOP", "LOOK","DANGER" or any words, phrases, symbols, or characters in such a manner as to interfere with, mislead or confuse traffic. 9. Signs painted directly on a building surface will not be permitted, this also includes painting the background a color differing from the intended building color palette. 10. Wall signs may not project above the top of a parapet, the roof line at the wall, or roof line. No roof signs. 11. No sign shall project above or below the sign area. The sign area is defined in the attached exhibits E-1 thru 2. 12. Vehicle Signs on or affixed to trucks, automobiles, trailers, or other vehicles which are use for advertising, identity, or provide direction to a specific use or activity not related to its lawful activity are prohibited.( i.e. Delivery trucks with tenant signage are okay as long as such trucks are not parked in such a manner to advertise along any major & minor streets.) 13. Banners, flags, kites, pennants, balloons, or other such advertising devices or displays, except as permitted according to the provisions under signs permitted in residential districts and special signs permitted in commercial and industrial districts. 14. Signs which revolve, rotate, move, flash, reflect, blink, or appear to do any of the foregoing, including searchlights, and animated signs shall be prohibited unless required by law or utilized by a proper government agency, with the exception of approved time and temperature displays. 15. Electronic message board signs, except those which display time and temperature. EXTEMPORANEOUS SIGNS Any banners, balloons, window signs, vinyl graphics or signs not listed within this Master Sign Program are to first receive approval from the Landlord, or it's designee, along with the City of La Quinta 's Planning Department before installation and are subject to the current city code. MODIFICATIONS TO SIGN PROGRAM Any changes or modifications to Madison Square Sign Program can be approved by The City of La Quinta Planning Director, unless The Planning Director deems the change or modification to be brought forth to The Planning Commission. CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. AREA Overall sign area is defined as a single or split area enclosed by a continuous line composed of 90 degree angles not to exceed u breaks. Any trim, backing, frame, structure and or element used to differentiate the sign from its background will be included in the calculation of allowable square footage. — —, — — — Allowed Sign Area (Copy Logo) — — Allowed Sign Area Split (8 Total 90 Degree Breaks) F——---——— — — — — — — I I Descending letter logo elements changed from the intended font will be included with the allowable copy height and square footage. - --------- Tenant to Determine Logo & Copy Color along with shapes as per their Nationally Recognized Trademarks. Allowed Sign Area Single I (8 Total 90 Degree Breaks) I — — — — — — — — — — — anL -, I - � I I I - - -- - Descending letter elements in certain fonts such as letters f, g, j, p, q, y & z will not count against allowable copy height and square footage as long as it does not serve as a logo element and/or has been changed from the intended font. Irregular shaped icons & logos should be considered in sign design for increased visual impact. However, flat cut out painted aluminum shapes or elements placed near, in front of or behind logo and/or letters are prohibited. RAWnA�Odl{w CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. NOTE: Color call -outs apply to building surfaces only. However, it is strongly suggested to consider them when choosing tenant sign colors. Lucida Calligraphy (Center Name Only) AaB6CcDdEeFfGgHhliJCXkLlMmNnOoPp2aRrSs7"t'LLufVvlWtivxxlJyZz -1234567890 Helvetica Bold (Building &Tenant Space Addresses Only) ABCDEFGHIJKLMNOPQRSTUVWXYZ - 1234567890 Dunn Edwards Paints Warm Hearth De6110 Edwards Center Ridge De6230 Dunn Edwards Paints � Western Red De6090 CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. F­ZirHl'Y Site Plan inw.!x•10 F r .....I I ! Ot20- - A.O.W. ' 1 p � ■ !I I R.O.W. U 1 u I O 4 4 Q is 1 O O O o � y ¢ O b Fl �� O o ! s � r r+ O O O �� 1 ` O O- O O I jj � Q `, l! i ' I ■ BLDG 1 O fI .':�• Q p O O er.DGs I b O O O ' O !� O 4 j OIL 00 s C -2=L C— it laCl a ' i �J�f 20'-0" R.O.W. 2o' -v" R.O.W. R. 0. Not to Scale ® Monument Signs 0' 62.1/2' 125' 250' ® Tenant Sign Options Tenant Sign Options ® Tenant Sign Options Tenant Sign Options Li SITE PLAN CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. 9 .. South Elevation Scale: 1/16" = V-0" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. Tenant may choose one (1) of the three areas shown West Elevation Scale: 1/16" = V-0" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. PLEASE NOTE: CONCEPTUAL DRAWING ONLY: 0' 6' 12' 24' 48' Size: 1.0 square foot of sign per Dimensions are approximate & may change due to linear foot of leased frontage (measured from construction are as c or exact printing willd l altos. Colors W%omm"Mmo� shown are as close as printing will allow; always parking lot side of building) not to exceed follow written specifications. 50 Square Feet per sign, with a total of 2 signs n r%f fA nvrioari inn CMI Inra fAQf CV W Z 0 W Z H O V a 0- Elevation Key ALL RIGHTS RESERVED: This design has been created for you in connection with a project being planned for you by AD ART. It may not be shown to anyone outside your organization, and may not be reproduced in any manner without prior consent. O 0 L N t/f 0% E • Baa 0 wpm . 0• V12 ; Z Co J W O W Z i= Z O W O m Q W D Z H Z O V South Elevation (West Half) Scale: 1/16" = 1'-0" Sign Placement for tenants occupying more then one space shall be determined by Tenant and Landlord, and if necessary Approved Sign Areas the City Planning Director. Manufacture and install single faced illuminated logo & letters on allowed sign band. West Elevation (East Half) Scale: 1/16° = V-0° Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. 0' 6' 12' 24' 48' 6%mrm%�� -1 PLEASE NOTE: Size: 1.0 square foot of sign per linear foot of leased frontage (measured from parking lot side of building) not to exceed 50 Square Feet per sign, and One (1) signs per in-line tenant, total sign area not to exceed cn ­­_ tee. CONCEPTUAL DRAWING ONLY: Dimensions are approximate & may change due to construction factors or exact field conditions. Colors shown are as close as printing will allow; always follow written specifications. .1111011ir W Ln r- C%4 0 0 QV) ' W CID 0 E ci Lu EJ Zt3 �a � Z ° • Cr u0D Z Ca 0 Elevation Key ALL RIGHTS RESERVED: This design has been created for you in connection with a project being planned for you by AD ART. It may not be shown to anyone outside your organization, and may not be reproduced in any manner without prior consent. w East Elevation Scale: 1 /32 " = 1'-0" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. West Elevation Scale: 1 /32 " = 1'-0" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. �!!� South Elevation Scale: 1 /32 " = 1'-0" A roved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. evation - Sign area based on boxed -in method with ird spacing = 100 square feet. West Elevation - Sign area based on boxed -in method with standard spacing = 158 square feet. South Elevation - Sign area based on boxed -in method with standard spacing = 158 square feet. i Elevation Key O' G' 12' 24' 4S' Dimensions are CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. END CAP SPACE 3 SIGNS 35'-5" 26'-8" ■� West Elevation 151-10111 IN LINE TENANT SPACE= 2 SIGNS 33'-10" 15-10"H I � 1 Scale: 3/64" = 1'-0" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. 23'-88 U 24',,.311. - 18'-4" END CAP SPACE_ 3 SIGNS331-511 5 L 10 18'-4" 0' 6' 12' 2N 48' Sign Placement for tenants occupying more then one space shall be determined by Tenant and Landlord, and if necessary the City Planning Director. I� SIGN AREA P _ 5)GN ARE►4 1 _, , IGN AREA 2n End Cap Space, maximum 3 signs, 1 square foot of sign per linear foot of leased frontage (pleasured from parking lot side of building), 1 sign per elevation not to exceed 50 square feet per sign, for a total of 150 square feet. North Elevation Scale: 1/16" = 1'-0" Approved Sign Areas Tenant may choose one (1) of the two areas shown Manufacture and install single faced illuminated logo & letters on allowed sign band. a 6' 12' 24' 48' PLEASE NOTE: Size: 1.0 square foot of sign per linear foot of leased frontage (measured from parking lot side of building) not to exceed 50 Square Feet per sign, and Two (2) signs per in-line tenant, total sign area not to exceed 100 square feet, and 3 signs per end cap tenant, total sign area not to exceed 150 square feet. f� ? E Elevation Key CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. C � F.'riure END CAP SPACE_ ,;� IN LINEJ;M;� T SPACE= 2 SIGNS f.r 3 SIGNS � 33'_9"-afi�-�" 21'-6" �0��23w.1,.015'-10"�, O�� 15-10" East Elevation Scale: 3/64" = 1'-0" lApproved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. SIGN AREAJ01: ".1119 19'-3" I END CAP SPACE 3 SIGNS - 23'-8" 381-411 18'-4" _� '4! 0' 6' 12' 24` 48' Sign Placement for tenants occupying more then one space shall be determined by Tenant and Landlord, and if necessary the City Planning Director. 191-311 SIGN AREA ■ End Cap Space, maximum 3 signs, 1 square foot of sign per linear foot of leased frontage (measured from parking lot side of building), 1 sign per elevation not to exceed 50 square feet per sign, for a total of 150 square feet. South Elevation Scale: 1/16" = 1'-0" Approved Sign Areas Tenant may choose one (1) of the three areas shown Manufacture and install single faced illuminated logo & letters on allowed sign band. 0' 6' 12' 241 48' 6%0m=%Mmmm� PLEASE NOTE: Size: 1.0 square foot of sign per linear foot of leased frontage (measured from parking lot side of building) not to exceed 50 Square Feet per sign, and Three (3) signs per in-line tenant, total sign area not to exceed 7 .Cn ­­ ieea 5 Elevation Key CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. M _� fa0161 8" West Elevation Scale: 1 /16" = 1'-0" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. liillllglll� North Elevation Scale: 1 /16" = 1'-0" 0' 6' 12' 24' 48' CONCEPTUAL DRAWING ONLY: Dimensions are approximate & may change due to construction factors or exact field conditions. Colors shown are as close as printing will allow; always follow written specifications. w 0 - Elevation Key ALL RIGHTS RESERVED: This design has been created for you in connection with a project being planned for you by AD ART. It may not be shown to anyone outside your organization, and may not be reproduced in any manner without prior consent. •I/ East Elevation Scale: 1 /16" = V -a" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. �� South Elevation Scale: 1 /1 6" = V -D" Approved Sign Areas Manufacture and install single faced illuminated logo & letters on allowed sign band. D' G' 12' 24' 48' W600=%=N=E� Elevation Key J CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. RM!8 ■ 11'-5" _ s'_4„ - 71-411 _ 31-71J I -X C42 2 Madtson S ■- -- - — 1 I %_ N I k A, , - Monument Elevations Scale: 1/2" =1' -0" Face Layout - (7) Tenants per side Sq.Ft.=50' -0" Manufacture and install three (3) D/F Internally illuminated monument signs with illuminated changeable tenant panels and routed out tenant graphics. 01 6" 1, 21 41 8' ■ I X-011 1`-103� low" t .. I N i Monument Specifications Specifications: Description Specification/Material Finish Color Top Trim Aluminum Painted Western Red #De6090 Cabinet Aluminum Painted Warm Hearth #DE6110 "Madison Place" copy Routed out Aluminum Acrylic Day/Night Acrylic Tenant Cabinets 2" Deep Alum. Pans Painted Western Red #De6090 Face Backing 3/16" Acrylic Acrylite White#015-2 Tenant Graphics 3M Vinyl Graphics Translucent Series 3630 to match client spec Base/Side columns Aluminum w/1/8" routed grooves Painted Wandering Road #DE6076 Illumination Fluorescent Lamps N/A Cool White NOTE: The Landlord shall approve the final tenant placement. Tenants shall be responsible for individual panels. CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. G.7G ! rsLJ.7 CL.TIM.Y.� n+�. CA STATE SUITE EL SEGUNDO, CA T 310.297.9777 F310.297.9780 CONTRACTORS LICENSE www.adart.corn 1250 90245 #B260S I OW 1.1 G. NO. N Tenant Addresses - Window Vi Numeral Layout Manufacture and instal first surface white vinyl address numerals. VARIES Scale: 6" = V -a" PLEASE NOTE: CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: *Exact address method per city code. Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. � oLn N ND` = aV O 0 a a � ZC'd w 1 1 � t r r I 01 ` if f t I f of r t PLEASE NOTE: CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: *Exact address method per city code. Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. � oLn N ND` = aV O 0 a a � ZC'd w LOGO AREA Tenant Sign (Inline NOT TO EXCEED 70% OF DESIGNATED SIGN BAND/WALL. Tenant to determine copy, color, logo shapes & logo placement as per their nationally recognized trademarks. Scale: 1/4" =1' -0" Logo & Letter Layout Manufacture and install single faced illuminated logo & letters on allowed signband. Daytime Simulation Nighttime Simulation 5" 011211 6 L 12" Aluminum clips attached returns with #8 self-laping screws. Toggle and/ or lag anchors based on letter placement (3/8' min of six per. 1k). — Low yoRage 12V DC 3/16"acryllo fares ` transformer tenant color spec. II conbkffd within sheaf metal box I Jewlite or variant Irlmca fastened wlth#8 Drillqu/ck hex screws painted to match trimcap. .083 aluminum Letter Retums Painted with Matthews to match Mullion Color Dark Bronze Letter Interiors l Pre-Anlshod - Bright whllo Iz' conduit pass thru. Tillo 24 compliant 12 V white LEDs Eht hkallunchon box located behind sign area. �.I YL !!sled dlsconnoe[ switch. ..I t 129 vall2tl amp dedicated clmuit '/l diameter weep holes power provided within with light baffles S of sign area by landlord. Channel Letter Section (Reference Only) CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: 05 6" 20 41 $' Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. NOT TO EXCEED 70% OF DESIGNATED SIGN BAND/WALL. 51, iNIN "A� mn -ME Tenant to determine copy, color, logo shapes & logo placement as per their nationally recognized trademarks. Tenant Sign Inline) Scale: 114"' =1' -0" Logo & Letter Layout Manufacture and install single faced illuminated logo & letters on allowed signband. Daytime Simulation Nighttime Simulation 5" Aluminum clips attached t returns with #8 set -taping screws. Toggle and/ or lag anchors based on later placemen (3/8' min of shr per. Hr.). L Low Voiiago 12v DC 3/16" acrylic faces translormer tenant color spec. contained within shestrnetelb" %, Jew1He or varlant frf nca Fastened wit►#8 Drillqulckhex screws painted to match trimcap. .063 aluminum Letter Returns Painted with Mathews to match Mullion Color Dark Bronze Letteriated rs Pre -finished - Bright While 'h"condultpass thru. 7it1e 24 compliant 12V white LEDs Electrical junction box l+� located behind sign area. Ut listed disconnect switch. 128 MR28 amp dedicated circut Y; diameter weep holes power prowded wthin with flghl baffles 5 of sign area by landlord. Channel Letter Section (Reference Only) CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: 0' 6" 1' 21 41 8' Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. - M CO i '- .. - - - - - - - - - N � i i 28'-91 /2" 5" 22'-10 5/8" 5" co 0 M ■ ■■/�T'T T C -LU -1-1111 N---��V '---- ._----h-].C-�r���-^af-Y-lRS=C---3-C-}•C-I Colors to match nationally recognized trademarks. Colors to match nationally recognized trademarks. Sign area based on boxed -in method with standard spacing = 158 square feet. Tenant Sign (Inline Scale: 3/16" = V-0" Logo & Letter Layout Manufacture and install single faced illuminated logo & letters on allowed signband. Daytime Simulation Nighttime Simulation Sign area based on boxed -in method with standard spacing = 100 square feet. 5" 0" 2" 6" 12" Toggle and/ or lag anchors - based on letter placement (3/8' min of sbr per. Hr.). Low Voffage 12v DC 3115"acrylic laces Iranslomler Conant color spec. contained within ahae[melat boa: Il dawlite or varlant trimca fastened wi1h#8 Drillqulckhex screws painted to match trimcap. .063 aluminum Letter Returns Painted with Matthews to match Mullion Color Dark Bronze = Letter loterlors Pm1kished - Bright White lhcondull pass Ihru. TIN& 24 compliant 12V white LEDs Electrical /unction box F. located behind sign area. ;c• UL listed dlscoerzect switch.l 72& voll 24 amp �`... dedicated circuil 1/l diameter weep holes power provided wMn wfth Ilght baffles S of sign area by landlord. Channel Letter Section (Reference Only) CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: 01 21 41 81 16' Dimensions are approximate & may change due to This design has been created for you in connection - I construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. am a �—V d da NONE 10'- 51/8" 9'- 71/2" 21/2" 4' DISCONNECT--& SWITCH IN=NmO T0 SQUARE FOOTAGE UPPER ARROW: 31.9 SQ FT LETTERS: 15.8 SQ FT LQ09A&WD-+1 : I &XF1 49-5 SQUARE FEET TOTAL AREA EL&ArION VIEW 510E "W Tenant Sign --Double Line Scale: 3/8" - I ' -0" Logo & Letter Layout Manufacture and instal install single faced illuminated logo & letters on allowed signband. vm Daytime Simulation Nighttime Simulation 0' V 2' 4' 8' WALL/ BUILDING FACE (THICKNESS MAY VARY) MODIFIED ACRYLIC FACE YELLOW NEON GRID TRANSFORMERS INSULATED CANDUIT G -CUP CONNECTION INSULATED CONDUIT ATTACHMENT/ MINIMUM b" O.C. OR AS REQUIRED YELLOW TRIM CAP - ALUMINUM RETURNS AND BACKS' PROVIDED WEEP HILES WALL / BUILDING FACE (THICKNESS MAY VARY) MODIFIED ACRYLIC FACE LED LIGHT SEGMENT (TYP)------ INSULATED CONDUIT TRANSFORMER ALUMINUM LED SEGMENT STANDOFF PLATFORM 3/8" X 2" LAGBOLT ATTACHMENT b" OC AS REQUIRED • t _ r . • NOTE: ALL LIGHITNG COMPONENTS TO BE UL LISTED. PROVIDE DISCONNECT SWITCH ARROW TO BE ILLUMINATED WITH 15mm YELLOW NEON AS REQUIRED. LED ILLUMINATION FOR COPY (AS SHOWN). . GOLD TRIM CAP ALUMINUM RETUNS AND BACKS/ BACKS FROVIDE WEEP HOLIESGOPr SIC100h SECTION & ATTACHMENT DETAIL •t Channel Letter Section (Reference Only) CONCEPTUAL DRAWING ONLY: ALL RIGHTS RESERVED: Dimensions are approximate & may change due to This design has been created for you in connection construction factors or exact field conditions. Colors with a project being planned for you by AD ART. shown are as close as printing will allow; always It may not be shown to anyone outside your follow written specifications. organization, and may not be reproduced in any manner without prior consent. � i1-117 i J M