Loading...
MA 2004-536OF ' QUINT, ,pNCE Case No.,AfA 6'(- � 1 Fee: $200 -C—ommu�nity Development Departvi*ft 28 2004 A� of INV A APPLICtWNT --Submit this form with two copies of a scaled site plan, drawn to adequately depict the nature of the request, A nonrefundable fee of $200 is required when the Application is submitted. The check must be made payable to the "City of La Quinta". A Minor Adjustment Permit (Section 9.210.040/Zoning Ordinance) may be approved only for deviations of up to ten percent of a numerical development standard (for example, a reduction of one foot from a fen -foot setback requirement) or for deviations specifically identified in the La Quinta Zoiung Ordinance. Other deviations shall require consideration of a variance (pursuant to Section 9.210.030/Variance\Zoning Ordinance). If t owner of the property, a letter must be submitted by the owner authorizing the Applicant to execut o t Es Palf. PLEASE PRINT OR TYPE CIA "—.5 r�4 GPM NT APPLICANT/CONTRACTOR: eAln%j_ flzmd 14 W DATE: CONTACT PERSON (IF DIFFERENT): AN G, hhpCWL PHONE: 2T 24 47 MAILING ADDRESS: 200 ef-j_ M,&IfjrJ" t1M 300 GOIZ�1�_ (tee.. 92882 OWNER'S NAME: MAILINGADDRESS: (Address) (City) (State) - - (Zip) (Address) STREET ADDRESS OF PROPERTY: (City) LEGAL DESCRIPTION OF PROPERTY: LOT # 4rr TRACT 24$ ASSESSOR'S PARCEL NUMBER: 7ms9Qrj' (Zip) ADJUSTMENT REQUESTED: _ f• FOR REQUEST: SIGNATURE OF APPLICANT DATE T— A�7 -O zl SIGNATURE OF OWNER (if not the same as ap cant) PLANNER: The following findings shall be made by the decision -snaking authority prior to the approval of any Minor Adjustment Permit: 1. Consistency with General Plan. The project is consistent with the General Plan. 2. Consistency with Zoning Code. The project is consistent with the provisions of the Zoning Code. 3, Compliance with CEQA. Processing and approval of the permit application are in compliance with the requirements of the California Environmental Quality Act. 4. Surrounding Uses. Approval of the application will not create conditions materially detrimental to the public health, safety and general welfare or injurious to or incompatible with other properties or land uses in the vicinity. A2\Fonn013 P.O. Boa 1504 78-495 CALLE TAMPICO (760)'777-7000 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7101 June 2,. 2004 Mr. Brian Nebel Capital Pacific. Homes 200 South Main Street Corona, CA 92882 SUBJECT: MINOR ADJUSTMENT PERMIT 2004-536. (SIDE YARD SETBACK ENCROACHMENT) Dear Mr. Nebel: Please let this letter stand as notification .that the Community Development Department ..has reviewed your Minor. Adjustment application, pursuant to Section 9.210.040 of the .City of La Quinta Zoning Code. Your request for an encroachment of six inches (6") into the required side yard setback. of five (5) feet (Lots 5 thru 12 and Lot 37 of Tract 24890-4) in order. to Legalize the residence has been approved based on the following Findings: FINDINGS: 1.. The Minor Adjustment is consistent with the _La Quinta General Plan., in that the request does not alter the approved land use for the property, or affect land uses'on surrounding properties. 2. The Minor Adjustment is consistent with the intent of the La Quinta Zoning Code, in that the request is for a deviation of no more than 10%, of a. development standard. Ten percent is the maximum deviation of any code pursuant to Section 9.210.040 of the Zoning Code. 3. Approval and execution of. the Minor. Adjustment is not detrimental to the public health, safety and general welfare, nor ..injurious or incompatible with other properties and land uses in the vicinity. The adjustment has no impact on health and safety issues, and will not affect.physical land use characteristics in the vicinity. } Mr. Nebel Page 2, 4. Processing and approving.. the Minor Adjustment .is Categorically Exempt with regard to the requirements. of the California Environmental Quality Act (CEQA), pursuant. to . CEQA Guidelines Section 15305(a). No further environmental analysis is:required. Please be advised that this approval relates only to :the allowance in. a reduction of the side yard setback as stated above. This approval does not imply any. entitlement or approval of..a building permit :for any structure(s). shown on the plans on file. -All other setback provisions ,and development standards of the La Quinta Zoning Code are applicable and shall be adhered to in preparing plans for, the Building Department. Should you have any questions or . need. additional information, please .contact,me at your earliest convenience at (760) 777-7068. Sincerely, JERRY HERMAN COMMUNITY DEVELOPMENT DIRECTOR MARTIN MAGA A Associate Planner C: Building & Safety Department \\CLQADMFSI\PLANNING\Martin\MAP's\MA 04536 Cap. Pac. Homes.doc to W N z Z_ Z 3I 50TH AVENUE t5 0 O W O ADAMS STREETG,T z � O39 z Q N W W m W 52 AVENUE z a VI WY MAP K NOT TO SCALE LEGEND DEEPENED FOOTING ED EXTRA DEPTH FOOTING AC AIR CONDITION UNIT PAD PE PAD ELEVATION FFL FLOW LINE GF GARAGE FLOOR FF FINISHED FLOOR FG FINISHED GRADE TC TOP OF CURB HP HIGH POINT BD BACK OF DRIVE GARDEN WALL " -S EXISTING SEWER MAIN W EXISTING WATER MAIN EXISTING SEWER LATERAL TO REMAIN PROPOSED SEWER LATERAL - - - - - - - - - EXISTING SEWER LATERAL TO BE REMOVED n EXISTING AIR RELEASE VALVE z. EXISTING FIRE HYDRANT PROPOSED WATER SERVICE EXISTING WATER SERVICE TO REMAIN _ - - - - - - - EXISTING WATER SERVICE TO BE REMOVED EXISTING IRRIGATION SERVICE OWNER / DEVELOPER CAPITAL PACIFIC HOMES 4100 MAC ARTHUR BOULEVARD SUITE 200 NEWPORT BEACH, CALIFORNIA 92660 (949)622-8400 FAX (949)622-8404 LEGAL DESCRIPTION LOT 2 OF TRACT 24890-4 AS RECORDED IN BOOK 218 PAGES 1-9 RECORDS OF RIVERSIDE COUNTY, STATE OF CALIFORNIA ASSESSOR 'S PARCEL NO: S 769-600-51 BASIS OF BEARING THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF JEFFERSON ST. SHOWN AS N W12'47" W ON RECORD OF SURVEY FILED IN BOOK 73, PAGE 83 OF RECORDS OF SURVEY RECORDS OF RIVERSIDE COUNTY, CALIFORNIA, Ali 7.50' LAlb I 4" SS SEE SHEET 2 SVS. Aft~ i ~9 - UNDERGROUND UTILITIES PRIVATE ENGINEERING NOTE `'' III no am saM.Tz S THAT IN ACCORDANCE WITH GENERALLY Q�OFESS/pN' EXI�SIT—M►�VOR ADJUSTMENT STRUCTURES REPORTED BY THE OWNER OR CONSTRUCTION CONTRACTOR AGREE NE WITH WILL GENERALLY �O �•i C. l SHT. ALL UNDERGROUND UTILITIES OR S1RUC RECORDS EXAMINED ARE INDICATED WITH ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CO 78-900 Avenue 47, Suite 208 (760) 771-4013 OTHERS AND THOSE SHOWN ON THE TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE ��� t�� '� �y� La Quints. CA 92253 FAX n1-4o73 TRACT NO. 24890-4 THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY ACCEPTING REQUIRED _ --- WITH IMPROVEMENTS PURSUANT THERETO, AGREES CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THE PROJECT. �' No. 20596 I THE PREMIER COLLECTION THESE PLANS OR PROCEEDING THAT THIS REQUIREMENT OF SHTS. TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, TO ENKiINEERING SURVEYING RESULTING FROM EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT SHALL BE MADE TO APPLY CONTINUOUCONTRACTOR AGREES SLY AND NOT BE TO DEFEND, NORMAL d*� . IVI ��* Q f , REPORTED TO THE UNDERSIGNED, NOT INDICATED OR SHOWN ON THE RECORDS WORKING HOURS, PROFESSIONAL HARMLESS FROM q�E' EXP. 9-30-2005 SCALE: 1" = 20' O.D. a -3-70 FD. 1 . 0. O.D.LP. FILLED w C .L T. 5 LOTS NO. �� 6! `'' E EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY INDEMNIFY AND HOLD DESIGN PROFESS qr CAL\ STANLEY MORSE MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER ANY AND ALL LIABILITY. REAL OR ALLEGED. IN CONNECTION WITH THE O.D. CONC. COLLAR DN. 0.6, 330' NORTH OF CL Mi. OF UTICITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE CONTRACTOR'S PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING MARK REVISIONS APPR. DATE R.C.E. 20596 WASHMGT�ON STREET dC 52nd AVENUE dC 6 2' SOUTH OF PP# 98927D. ELEV. 5�0.110 CARTAL LE NEGLIGENCE OF DESIGN PROFESSIONAL DATE: CONTOUR DATUM IS SEA LEVEL PLUS 500 FEET M AVOID NEGATIVE NIA�RS FOR: CjA1-1 1 AL PACF C HOMES W.O. N0: RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES FROM THE SO DESIGNED BY: K.D. DRAWN BY: K.D. CHECKED BY: E.L. W CONCERNED BEFORE STARTING WORK. - � THE CITRUS I: \35944\PG\EXHIBIT-MINOR ADJ-01.dwg 5/20/2004 - __ I UNDERGROUND UTILITIES ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO, AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED, NOT INDICATED OR SHOWN ON THE RECORDS EXAMINED. THE CONTRACTOR IS " REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 7.5' 56.57 24.5" 9" MIN --, Q Z I Lo J AC J NUj o En 0 00 SIDE YARD TYPICAL AC UNIT PAD DETAIL NOT TO SCALE N O i PRIVATE ENGINEERING NOTE PREPARED UNDER THE DIRECTION OF: N D S CONSUL - r / N Q N Tm wy OF LA ouw& sTA-m OF CALFomA � dcsrr MavoR Ao.�sTMENT CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE ROF�g� pQ YORSE m oc11 sc ftu 2 C REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE �Y �. 78-900 Avenue sw. Q CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THE PROJECT. 4� �. �y '— 47, Suite 208 (760) 771-4013 �! " �"Z La Wonta, CA 92253 FAX 771-4073 /`1CT NO. 24890- 4 INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT No. 20596 SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR AGREES TO Exp. 9-30-05 THE PREMIER COLLECTION OF 3 sHTs. E a�No rsuRv o .DEFEND, INDEMNIFY D HOLD DESIGN PROFESSIONAL 4HINCONNEC71ON ANY AND ALL LIABILITY, RORALLEGED, WITH THE � � CAU n LOTS �7 S NO. 101 11 & 12 � STANLEY MORSE EXP. DATE: 2005 30 09 / / SCALE: 1" = 20' 8:. , PD-1o3-3-7o M. 1 1/� o.o.iP. FlLLED w/CONc. IN 5 MARK REVISIONS APPR. DATE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL R.C.E. 25906 DATE: O.D. CONC. COl1AR DN. 0.6, 330' NORTH OF C.L INT. OF WASFANGTON STREET lk 520d AVENUE do 6.2 SOUTH OF PP 98927D. E1J:11. 540.110 , DESIGNED BY: K.D. DRAWN BY: K.D. CHECKED BY: E.L. CONTOUR DATUM IS SEA LEVEL PUTS 500 FEET TO AVOID NEGATIVE NUMBERS. FOR: CAPITAL PACFIC HOMES W.O. NO: THE CITRUS I• \35944\PG\EXHIBIT-MINOR ADJ -02 dui 5/20/2004 g 7.5$ z J SCALE: 1" 20' \���-----EX " RCP 9 55'26"E STO M DRAIN 100.00' 37 I � III II MASTER BEDROOM , 7.50 I n III (I KITCHEN 5', PUE GREAT ,, I II 7.50 i 3 BEDROOM 3 PLAN 3R 'RAB ]- M • - O i >-- p z .- I I 1� SEE TYPICAL AC UNIT PAD DETAIL THIS SHEET —i CE EE.0 2 COURTYARD i I •' . . 5.5' GARAGE - .. - 1J c o �N.., I GARAGE i i SEE TYPICAL AC UNIT —PAD 9TTMG CASITA I ` DETAIL THIS SHEET W 32" CONC III a OiIVEWAY ::, I b SIDE YARD 0-------------- TYPICAL AC UNIT PAD DETAIL ^M � - + UNDERGROUND UTILITIES ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY 'ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO, AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED, NOT INDICATED OR SHOWN ON THE RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. NOT TO SCALE PRIVATE ENGINEERING NOTE CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THE PROJECT. INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. MARK 1 REVISIONS I APPR. 1 DATE DESIGNED BY: K.D. DRAWN BY: K.D. CHECKED BY: E. 4" SS SVC. 8" SANITARY SEWER II I F PREPARED UNDER THE DIRECTION OF: PREPARED A/ D S CONSUL T / N G N TIE CITY OF LA QUINTA, STATE OF CAWORNA MaiBIT3 -MINOR ADJUSTMENT C.LAND SHT G Q J y 78-900 Avenue 47, Suite 208 pso) n1-4o13 La OuIntc, CA gn53 FM 771-073 TRACT NO. 24890- 4 . * 1*Na THE PREMIER COLLECTION OF 3 SHTS. o No SURVE nNG LOT NO. 37 STANLEY MORSE SCALE: 1" = 20' ppl n MAAIC PD-103-3-70 M. 1 1/,C O.D.I.P. FlUED w/CONC. IN T RCE 20596 EXP. 09-30-2005 DATE: O.D. CONC- COUAR DN. 00. 330' NORTH OF C.L. INT. of WAS *CM STREET a 52nd AVENUE r!c 61' SOUTH OF PP# 98927D. ELEV. 540.110 CONTOUR DATM IS SEA LEVEL PLUS 500 FEET TO AVOID NEGATIVE NUMBM FOR: CAPITAL , PACM HOMES W.O. NO: THE CITRUS I:\35944\PG\EXHI8IT—MIN0R ADJ-03.dwg 5/20/2004