Loading...
SBA 1996-383CASE NO: 914 - 3 8 3 CITY OF LA QUINTA FEE: $100.0A PLANNING & DEVELOPMENT DEPARTMENT APPLICATION FOR SETBACK ADJUSTMENT APPLICANT: Submit this form with two copies of a scaled site plan, drawn to adequately depict the .nature of the request. A nonrefundable fee of $100 is required when the Application is submitted. Check must be make payable to the "City of La Quinta". If the Applicant is not the owner of the property, a letter submitted by the owner authorizing the Applicant to execute this;4et_U in his behalf. R70C **JAN*1�0 1996 PLEASE PRINT OR TYPE �BY APPLICANT/CONTRACTOR :Sty n 000 I. DATE Q &- CONTACT PERSON ( IF DIFFERENT) PHONE ?, MAILING ADDRESS: —{7. / I CJL-4, 04 iz qb l f/h ofe (Address) (City) OWNER'S"NAME: MAILING ADDRESS: ss VC- kvv_c (State PHONE _ ty), (State STREET ADDRESS OF PROPERTY: _59dQ / Q-en 91AL LEGAL DESCRIPTION OF PROPERTY: LOT # TRACT ASSESSOR'S PARCEL NUMBER: ADJUSTMENT REQUESTED: (zip zip) u ►V-, . JUSTIFICATION: No request for. a Setback Adjustment shall be granted unless it is determined that it is consistent with the intend and purpose of this Ordinance; that there are special circumstances applicable to the property, including such factors as size, shape, topography, location or surroundings that justify the approval of the adjustment of the setback requirement, and that the adjustment will not be detrimental to the health, safety, and general welfare of the community or be detrimental to property in the area of the parcel for which the adjustment is requested. FORM.013/CS ft rJLL oPy r 78-495 CALLE TAMPICO - 'LA QUINTA, CALIFORNIA 92253 (619) 777-7000 FAX (619) 777-7101 January 12, 1996 Mr. Bill Albers r 55120Inverness La Quinta, California 92253 SUBJECT: SETBACK ADJUSTMENT 95-383 LOCATION - 55120 Inverness, PGA West Dear Mr. Albers: - This letter is to report approval of your recent application for a setback adjustment, ' pursuant to Chapter 9.188 of the City of La Quinta Planning and Zoning Regulations. The following setback adjustment has been approved ,subject to conditions, and in accordance with attached Exhibits A, and B. , SETBACK ADJUSTMENT: 3-1/2' .rear yard setback reduction arid' 2' sideyard reduction r FOR. Swimming pool and spa in rear yard CONDITIONS: a. Obtain building permit from Building & Safety Department , b. Comply with , applicable, PGA, West' Homeowners. Association requirements.. After review it was determined that: 1. This adjustment is consistent with the intent and purpose of the zoning ordinance by still maintaining a private area adjacent to.common. open space. Itrss.343 MAILING ADDRESS - P.O. BOX 1504.• -' Lk OUINTA, CALIFORNIA 92253 ®(_/ r ' 2. There are special circumstances applicable to the property in that the location and surrounding area of the pool is adjacent to common open space. 3. This adjustment will not be detrimental to the health, safety, and general welfare of the community or be detrimental to property in the vicinity of the parcel for which the adjustment is requested because of the common open space area. Should you have any questions, please contact the undersigned. Very truly yours, . JERRY 'HERMAN . COMMUNITY DEVELOPMENT DIRECTOR STAN B. SAWA Principal Planner SS:cw Attachment: Approved Exhibits . cc: Building & Safety Department, City of -La Quinta Itrss.343 RAISED BEAMS SHEAR DESCENT tile facing above water areas, ALL CAPS APPROXIMATELY 15" WIDE WATERFEATURES stucco to match house all other areas I TO BE PLACED ON 12" WIDE BOND BEAMS. BACKHOE 5' wide, 6' wide, 5' wide (face, ends, & backsides) ACCESS concrete caps & stepups by owner. .L. + 211 +18" +12" --—�3,----- ------7�-------- ------------------------- ben 11611 b 1 e 11' tile trim all -5s's"min. c 1916" steps & benches\ / h 351+ 3' 6'+ all d by owner, match existutg. =" T--- -- --- S - 8 1 existing covered _ 1 covered patio 1 .patio F00 PX. J BOX LOCATIONS TO BE DETERMINED AT SITE BY ELECTRICIAN DIM ER CONTROL LIGHTS. gas .& electric stubs at equipment � . control switches stubbed to kitchen K K1016II)N,N(,h, APPROVED BY PLANNING & DEVELOPMENT DEPARTMENT . By EXHIBIT CASE NO. �g �5 ���3. fXFiIBIT SPA SPECS. .SIZE ' RAISED +18"" LITE 100W WATTS TRI LEVEL SEATS YES 22" 24" 27" DAMWALL WIDTH 6" X 9' SPILLWAY SIZE 12" X " OPEN XX CLOSED JETS.# 8 88 SQFT STUCCO, COLOR TO MATCH HOUSE P.L. CASE NO. a4e:2j 83 1flffiTER COPY G RAL SPECInCATIONS SIZE 11' .X 411611AREA 385 DEPTH 4' TO -5' TO 4' SHAPE PERIMETER TILE SIZECkJOICE OF GROUP 3 39' of +12" RBB w/ the Ft —rim m 24' of +18" RBB w/ the the COPING CANTILEVER 117' POOL CAPACITY 14,500 GALS PUMP CAPACITY 90 GPM MOTOR HP STA MAX 2 HP 2 FILTER SYSTEM 3 300 SQ FT FILTER RATE 100 GPM TURNOVER 3 HRS RETURN LINES. YES " sta max 2 1.5hp (w/falls) •, MAIN DRAIN YES " SKIMMER MODEL DUAL PORT CHECK VALVE YES HEATER LAARS SIZE 400,000 BTU GASLINE BY S.D.C. hookup only POOL LIGHT (3) 30OW SPA LIGHT. (1) 100W - CLOCK24HR 220V ELECTRIC BY S.D.C. 165' ELECTRICAL BONDING BY: S.D.C. TILE S.D.C. DECKING BY OWNER CONTRACTOR cannot assume responsibility for damage to curbs, sidewalks, driveways, cement slabs, sewers, lawns,trees, fences, retaining walls, sprinklers, telephone lines or shrubs. When access is made through a neighbor's property it is understood that you, -the owner, have that neighbor's permission . and assume full responsibility. Name:.ALBEIRS Address- 55-120 IN'VERNESS Co- 'LA QUINTA, CA. (PGAW) NOW7. POO/ SHOW ROOM 68-805-A PEREZ RD. STE. E-9 CATHEDRAL CITY CA. 92234 PHONE (619) 324-1232 UC # A-574127