Loading...
MBA 2018-0001 Target (03.13.2018) 78-495 Calle Tampico La Quinta, CA 92253 760.777.7000 March 13, 2018 Mr. Brian Leung Kimley Horn 765 The City Drive, Suite 200 Orange, CA 92868 SUBJECT: MODIFICATION BY APPLICANT 2018-0001 TARGET EXTERIOR REFRESH APPROVAL Dear Mr. Leung: The Design and Development Department has reviewed your request for a modification to the existing Target commercial building, located at 78935 Highway 111. The modifications include repainting and refreshing exterior walls, monument sign, and building mounted signs. It has been determined that said plan modifications are minor, will not result in a significant change in the project as approved by the decision-making authority, and comply with the spirit and intent of the Washington Park Specific Plan. Therefore, the design modification is approved as shown on the attached exhibits, subject to the following conditions of approval: 1.The applicant shall secure building and demolition permit approval from the Building division prior to the initiation of any work. 2.The applicant shall comply with Sign Application 2018-0004 for the new signs. Should you have questions, please contact me at 760-777-7069. Sincerely, Carlos Flores Associate Planner T-1867 La Quinta, CA: Exterior Elevation Refresh February 20, 2018 Proposed Elevations Front Elevation Right Elevation Rear Elevation Left Elevation EIFS C-1 “TARGET RED” (E) STONE VENEER (E) STONE VENEER (N) 14’-0” BULLSEYE (E) STONE VENEER (E) STONE VENEER (E) STONE VENEER (E) BULLSEYE TO REMAIN, REFURBISH AS NEEDED DEMO (E) FIN (N) EIFS 55’-0”3’-0” 10’-0”36’-0”3’-0”7’-0”17’-2”48’-8” (N) CANTILEVERED EIFS FIN (E) COLUMNS (E) SIGN TO REMAIN (E) GRAPHIC LOGO TO REMAIN, REFURBISH AS NEEDED (E)BRONZE ENTRY/STOREFRONT (E) BRONZE ENTRY/STOREFRONT (N) EIFS (N) EIFS REPAINT TO MATCH EXISTING FINISHES REPAINT TO MATCH EXISTING FINISHES REPAINT TO MATCH EXISTING FINISHES REPAINT TO MATCH EXISTING FINISHES24’-0”(E) C-41 “MEDIUM TERRA COTTA” - TK PRODUCTS CUSTOM FORMULATION (E) C-42 “MEDIUM KHAKI” - TK PRODUCTS CUSTOM FORMULATION (E) C-43 “LIGHT KHAKI” - TK PRODUCTS CUSTOM FORMULATION (E) C-44 “LIGHT TERRA COTTA” - TK PRODUCTS CUSTOM FORMULATION (E) C-45 “DARK KHAKI” - TK PRODUCTS CUSTOM FORMULATION EXISTING NEW (E) (N) (E) STONE VENEER (N) ORDER PICKUP SIGN PLANNING APPROVAL ADMINISTRATIVE CASE# ____________________ EXHIBIT# ____________________ INITIAL cflores DATE 03/13/2018 10:12:00 AM MBA2018-0001 Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 122 EXISTING CONDITION OF FRONT ELEVATION NTS EXISTING FRONT ELEVATION Scale: 1/32"=1'-0" C A 502'-8"±35'-11"± T-1867 La Quinta, CA: Exterior Elevation Refresh February 20, 2018 Proposed Front Elevation Front Elevation Right Elevation Rear Elevation Left Elevation EIFS C-1 “TARGET RED” (E) STONE VENEER (E) STONE VENEER (N) 14’-0” BULLSEYE (E) STONE VENEER (E) STONE VENEER (E) STONE VENEER (E) BULLSEYE TO REMAIN, REFURBISH AS NEEDED DEMO (E) FIN (N) EIFS 55’-0”3’-0” 10’-0”36’-0”3’-0”7’-0”17’-2”48’-8” (N) CANTILEVERED EIFS FIN (E) COLUMNS (E) SIGN TO REMAIN (E) GRAPHIC LOGO TO REMAIN, REFURBISH AS NEEDED (E)BRONZE ENTRY/STOREFRONT (E) BRONZE ENTRY/STOREFRONT (N) EIFS (N) EIFS REPAINT TO MATCH EXISTING FINISHES REPAINT TO MATCH EXISTING FINISHES REPAINT TO MATCH EXISTING FINISHES REPAINT TO MATCH EXISTING FINISHES24’-0”(E) C-41 “MEDIUM TERRA COTTA” - TK PRODUCTS CUSTOM FORMULATION (E) C-42 “MEDIUM KHAKI” - TK PRODUCTS CUSTOM FORMULATION (E) C-43 “LIGHT KHAKI” - TK PRODUCTS CUSTOM FORMULATION (E) C-44 “LIGHT TERRA COTTA” - TK PRODUCTS CUSTOM FORMULATION (E) C-45 “DARK KHAKI” - TK PRODUCTS CUSTOM FORMULATION EXISTING NEW (E) (N) (E) STONE VENEER (N) ORDER PICKUP SIGN Proposed MaterialsT-1867 La Quinta, CA: Exterior Elevation Refresh January 12, 2018 C-41 (E) MEDIUM TERRA COTTA C-42 (E) MEDIUM KHAKI C-1 TARGET RED C-43 (E) LIGHT KHAKI C-44 (E) LIGHT TERRA COTTA C-45 (E) DARK KHAKI 1.Front elevation facing Hwy 111: location of proposed “order pickup sign” on stone veneer 2.Front elevation facing Hwy 111: proposed cantilevered EIFS finish, removal of “TARGET” signage, proposed white bullseye 3.Existing Target Monument Sign at intersection of Avenue 47 and La Quinta Center Drive. Proposing white bullseye logo and white lower case “target” channelized lettering with earth tone background 4.Existing Target Monument Sign intersection of Highway 111 and La Quinta Center Drive, refurbish red bullseye logo with new red bullseye logo and lower case “target” channelized lettering with earth tone background 1 2 3 4 Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 121 PHOTOGRAPHIC SITE PLAN SCALE: N.T.S. PROPOSED NEW SIGN SCHEDULE NEW BULLSEYE LOGO WHITE / 14' 153.9 SQ. FT. QUANTITY: ONE (1)Front Elevation NEW TOTAL BLDG. SIGNAGE: 273.38 SQ. FT. A EXISTING 2'-6" RED CVS PHARMACY LETTERS /57.08 SQ. FT. QUANTITY: ONE (1)Front Elevation N NEW 1'-2" RED ORDER PICKUP CHANNEL LETTERS /24.59 SQ. FT. QUANTITY: ONE (1)Front ElevationB Front Elevation EXISTING SIGN SCHEDULE EXIST’G RED 12'-0" BULLSEYE LOGO / 2'-3" TARGET LETTERS QUANTITY: ONE (1)ON FRONT ELEVATION TO BE REMOVED & REPLACEDA140.1 SQ.FT EXISTING TOTAL BLDG. SIGNAGE: 197.18 SQ. FT. C EXIST’G RED 2'-6" CVS PHARMACY LETTERS QUANTITY: ONE (1)ON FRONT ELEVATION TO REMAIN AS IS. NO CHANGE 57.08 SQ.FT C D PROPOSED GROUND SIGN SCHEDULE 5 0 5 ' - 1 0 "±288'-8"± NEW 3'-6" RED FCO BULLSEYE LOGO /9.61 SQ. FT. QUANTITY: ONE (1) Rear ElevationENEW 6'-0" RED BULLSEYE LOGO /28.2 SQ. FT. QUANTITY: ONE (1) F G NEW BULLSEYE LOGO WHITE & 10 3/4" target LETTERS / 3'-6" 33.24 SQ. FT. QUANTITY: TWO (2)On La Quinta Center Drive Monument Sign NEW BULLSEYE LOGO WHITE & 10 3/4" target LETTERS / 3'-6" 33.24 SQ. FT. QUANTITY: TWO (2)On Avenue 47 Monument Sign NEW TOTAL MONUMENT SIGNAGE: 66.48 SQ. FT. G F B A D C E A Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 123 SCOPE OF WORK: EXISTING BULLSEYE & TARGET | ONE (1) SET EXISTING SIGN TO BE REMOVED & DISPOSED. A 140.1 SQ.FT A B C D E SIGN TYPE A B C D E SQ.FT.QTY 1 ACRYLIC FACED INTERNALLY ILLUMINATED CHANNEL LET TERS EXISTING TO REMAIN AS IS. NO ACTION.CHANNEL LOGO & LETTERS C SCOPE OF WORK: CVS-30-CL 57.0829 1/8"22'-10 "3'-1"6'-8"12'-2 1/4" A F B G H I J K D C E SIGN TYPE A B C D E HF IG J K SQ.FT.AMPS CIRCUITS RETAINER LL144/27S-R 12'-0"12'-0"12'-0"2'-0"2'-0"12"4'-0"2'-3"2'-0"2'-0"15'-8"113.1/27.0 logo/letters logo/letters 1.5" RET. / 1" T.C. 113.1/27.0 FIELD SURVEY REQUIRED Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 124 PROPOSED STORE FRONT ELEVATION1Scale: 1/32"=1'-0" PROPOSED RIGHT SIDE ELEVATION2Scale: 1/32"=1'-0" 505'-10"±35'-0"±24'-0"10'-0"14'-0"58'-0"20'-4"12'-10" 1'-2" 13'-5" 22'-10" 2'-6" 3'-6"25'-0"20'-3"288'-3"±35'-0"±CAB 23'-7 1/2" D 2'-2 1/2" 14'-0" Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 125 PROPOSED LEFT SIDE ELEVATION 3 Scale: 1/32"=1'-0" PROPOSED REAR ELEVATION4Scale: 1/32"=1'-0" 505'-10"±27'-10"±288'-8"35'-8"±8'-0"± 6'-0"23'-8"±E Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 126 A B C D E F G ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED SIGN TYPE A A B C D E F G SQ.FT.QTYRETAINER ANY DEVIATION FROM FEDERAL HEATH REQUIREMENTS MAY RESULT IN DAMAGE TO OR IMPROPER OPERATION OF SIGNAGE, CAUSING DELAYS AND ADDITIONAL COSTS. ELECTRICAL REQUIREMENTS Total: 0.0 Amps ( 1 ) 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. 6" .063 ALUMINUM RETAINER .080 ALUMINUM FILLER INTERIOR PAINTED: WHITE MINIMUM .090 ALUMINUM BACK ALL MOUNTING HARDWARE (INCLUDING SPACERS) TO BE SUPPLIED BY: INSTALLER MINIMUM 3/8” STAINLESS STEEL MOUNTING HARDWARE SLOAN LED (2) - WEEP HOLES PER LOW SPOT ½" ELECTRICAL BEYOND SIGN BY INSTALLER. INSTALLER TO PROPERLY SEAL WALL. PIGMENTED ACRYLIC FACES WALL J-BOX BY INSTALLER LOCK-ABLE DISCONNECT SWITCH BY OWNER-WIRED BY ELECTRICIAN. (1 PER CIRCUIT) EXISTING ELECTRICAL PANEL 12 V CLASS TWO POWER SUPPLY, SUPPLIED BY; FEDERAL HEATH MOUNTED BY: SUB-CONTRACTOR SPACE MAXIMUM 1" MINIMUM ½" POWER DISTRIBUTION BOARD BY: FEDERAL HEATH CLASS 2 SECONDARIES TO DISTRIBUTION BOARD TO BE RUN THROUGH CONDUIT SUPPLIED BY INSTALLER AND WIRED BY INSTALLER. DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. SEALER: BASF-MasterSeal NP 150 END VIEW 6"SPACE MAXIMUM 1" MINIMUM ½" Trimcap/Retainer Trimcap/Retainer WHITE 7328 WHITE ATUGLAS Acrylic WHITE Sloan White LED MATERIAL FINISH COLORS Returns Faces Retainer/Trim-Cap Illumination LOGO/WALL DETAIL NOT TO SCALE (Generic) 1168 BULLSEYE-W 14'-0"14'-0"2'-4"2'-4"2'-4"2'-4"4'-8"1 ½"153.9 NOTE: ENGINEERING REQUIRED FOR RED WALL PANEL Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 127 ANY DEVIATION FROM FEDERAL HEATH REQUIREMENTS MAY RESULT IN DAMAGE TO OR IMPROPER OPERATION OF SIGNAGE, CAUSING DELAYS AND ADDITIONAL COSTS. ELECTRICAL REQUIREMENTS Total: 0.0 Amps ( 1 ) 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. LOGO/LETTER WALL DETAIL NOT TO SCALE 5" 1" TRIM CAP .040 ALUMINUM FILLER PRE-FINISHED ALUMINUM MINIMUM .063 ALUMINUM BACK ALL MOUNTING HARDWARE (INCLUDING SPACERS) TO BE SUPPLIED BY: INSTALLER MINIMUM 3/8” STAINLESS STEEL MOUNTING HARDWARE SLOAN LED WEEP HOLES PER LOW SPOT ½" ELECTRICAL BEYOND SIGN BY INSTALLER. INSTALLER TO PROPERLY SEAL WALL. PIGMENTED ACRYLIC FACES WALL J-BOX BY INSTALLER LOCK-ABLE DISCONNECT SWITCH BY OWNER-WIRED BY ELECTRICIAN. (1 PER CIRCUIT) EXISTING ELECTRICAL PANEL 12 V CLASS TWO POWER SUPPLY, SUPPLIED BY; FEDERAL HEATH MOUNTED BY: SUB-CONTRACTOR POWER DISTRIBUTION BOARD BY: FEDERAL HEATH CLASS 2 SECONDARIES TO DISTRIBUTION BOARD TO BE RUN THROUGH CONDUIT SUPPLIED BY INSTALLER AND WIRED BY INSTALLER. DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. SEALER: BASF-MasterSeal NP 150 (Generic) ACRYLIC FACED INTERNALLY ILLUMINATED CHANNEL LETTERS MANUFACTURE AND INSTALL CHANNEL LETTERS AS SHOWN AND NOTED END VIEW 5" SPACE MAXIMUM 1" MINIMUM ½" AC B SIGN TYPE A B C SQ.FT.QTY 1 Red Sloan Red LED MATERIAL FINISH COLORS Returns Trimcap/Retainer Illumination MP# 82074LVG (FULL GLOSS) 2793 LD Red Modified Acrylic (Altuglas or Equiv.) Faces 1'-2"OPU14-REMOTE-R 1'-11"24.5912'-10" B NOTE: ENGINEERING REQUIRED FOR STONEWOOD VENEER Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 128 END VIEW A B C D E F G FLAT CUT OUT ALUMINUM "BULLSEYE" LOGO MANUFACTURE AND INSTALL FCO LOGO AS SHOWN AND NOTED SIGN TYPE A B C D E F G SQ.FT.QTY 42 BULLSEYE-R 1 MATERIAL FINISH COLORS ALUMINUM MP# 82074LVG (FULL GLOSS) Mounting Surface 1/4" Aluminum Spacer, Typical 1/8" Thick FCO Aluminum 3/16" Diameter Aluminum Studs, Min. 3 Per Element painted t/m MP#82074LVG Full Gloss 3'-6"3'-6"7"7"1'-2"7"7"9.61 D FCO LOGO Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 129 END VIEW 6"SPACE MAXIMUM 1" MINIMUM ½" A B C D E F G ACRYLIC FACED INTERNALLY ILLUMINATED "BULLSEYE" MANUFACTURE AND INSTALL CHANNEL LOGO AS SHOWN AND NOTED SIGN TYPE A B C D E F G SQ.FT.QTYRETAINER ANY DEVIATION FROM FEDERAL HEATH REQUIREMENTS MAY RESULT IN DAMAGE TO OR IMPROPER OPERATION OF SIGNAGE, CAUSING DELAYS AND ADDITIONAL COSTS. ELECTRICAL REQUIREMENTS Total: 0.0 Amps ( 1 ) 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. LOGO/WALL DETAIL NOT TO SCALE 6" .063 ALUMINUM RETAINER .080 ALUMINUM FILLER INTERIOR PAINTED: WHITE MINIMUM .090 ALUMINUM BACK ALL MOUNTING HARDWARE (INCLUDING SPACERS) TO BE SUPPLIED BY: INSTALLER MINIMUM 3/8” STAINLESS STEEL MOUNTING HARDWARE SLOAN LED (2) - WEEP HOLES PER LOW SPOT ½" ELECTRICAL BEYOND SIGN BY INSTALLER. INSTALLER TO PROPERLY SEAL WALL. PIGMENTED ACRYLIC FACES WALL J-BOX BY INSTALLER LOCK-ABLE DISCONNECT SWITCH BY OWNER-WIRED BY ELECTRICIAN. (1 PER CIRCUIT) EXISTING ELECTRICAL PANEL 12 V CLASS TWO POWER SUPPLY, SUPPLIED BY; FEDERAL HEATH MOUNTED BY: SUB-CONTRACTOR SPACE MAXIMUM 1" MINIMUM ½" POWER DISTRIBUTION BOARD BY: FEDERAL HEATH CLASS 2 SECONDARIES TO DISTRIBUTION BOARD TO BE RUN THROUGH CONDUIT SUPPLIED BY INSTALLER AND WIRED BY INSTALLER. DISTRIBUTION BOARD AND POWER SUPPLIES SUPPLIED BY FEDERAL HEATH SIGN CO. SEALER: BASF-MasterSeal NP 150 (Generic) 1 Red Sloan Red LED MATERIAL FINISH COLORS Returns Trimcap/Retainer Illumination MP# 82074LVG (FULL GLOSS) 2793 LD Red Modified Acrylic (Altuglas or Equiv.) Faces 72 BULLSEYE-R 6'-0"6'-0"1'-0"1'-0"1'-0"1'-0"2'-0"28.21" E Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 1210701507-WP701507-WP701507-WP701507-WPSHIPPING NOTE: PLEASE SHIP ALUMINUM PANELS WITH POWER SUPPLIES IN THE SAME CONTAINER. 701507-WP END VIEW .125 ALUMINUM PAN POWER DISTRIBUTION BOARD (PDB) WITH 3/8” DIA. HOLES FOR MOUNTING BY FEDERAL HEATH SIGN. 120 V ON/OFF DISCONNECT, CONDUIT AND PRIMARY TO PDB INSTALLED AND PROVIDED BY G.C. ELECTRICIAN. TYPICAL ELECTRICAL COMPONENTS SHOWN, SUPPLIED BY INSTALLER - TO BE UL LISTED AND APPROVED PER NEC 2005 NEC 600-4, 600-3, FBS 4505-4 & DESIGNED TO U.L. 48 PER F.S. 553-19. SLOAN POWER SUPPLIES BY FEDERAL HEATH SIGN. INSTALLED TO BOARD BY SIGN INSTALLER. ELECTRICAL ( 2’-0” ) WHIP TWHN #12 WITH TYPICAL ELECTRICAL COMPONENTS SHOWN, SUPPLIED BY INSTALLER - TO BE UL LISTED AND APPROVED PER NEC 2005 NEC 600-4, 600-3, FBS 4505-4 & DESIGNED TO U.L. 48 PER F.S. 553-19. BUSHING PROVIDED BY SIGN INSTALLER. CLASS 2 12VDC 120/240 SECONDARY WIRES 2'-0"2'-2"2'-0" 2'-2" 1/2" scale 1 1/2" = 1'-0" ISOMETERIC VIEW (Power Distribution Board)(Generic) PLAN VIEW (Power Distribution Board) (Typical) scale 1 1/2"=1'-0" SCOPE OF WORK: FEDERAL HEATH SIGN TO MANUFACTURE A “POWER DISTRIBUTION BOARD” - ( PDB). TO BE .125 ALUMINUM BREAK FORMED PANEL ½” DEEP. PDB TO HAVE 3/8” MOUNTING HOLES PRE- DRILLED. INSTALLER TO MOUNT LETTERS TO EXTERIOR WALL AND RUN SECONDARY LEADS IN CONDUIT THROUGH WALL INTO A HANDI-BOX. CONDUIT THROUGH WALL TO BE SEALED FROM WEATHER WITH APPROPRIATE SEALANT SUPPLIED BY INSTALLER. INSTALLER TO WIRE ALL SECONDARY JUMPS TO CORRESPONDING LETTERS INSIDE BUILDING. INSTALLER TO WIRE SECONDARY LEADS TO POWER DISTRIBUTION BOARD THROUGH CONDUIT. INSTALLER TO COORDINATE LOCATION OF POWER DISTRIBUTION BOARD WITH TARGET ON SITE REPRESENTATIVE PER (E-8 SITE ELECTRICAL DRAWINGS). INSTALLER TO MOUNT PDB WHERE REQUIRED. PDB MAXIMUM DISTANCE FROM SIGNAGE IN ANY ONE DIRECTION IS 150 FEET. PDB TO BE MOUNTED USING ADEQUATE HARDWARE SUPPLIED BY INSTALLER. ELECTRICIAN IS TO SUPPLY AND RUN PRIMARY, CONDUIT AND DISCONNECT SWITCH TO PDB AND MAKE FINAL CONNECTION. ALL WORK TO BE DONE PER NEC, UL-48 AND LOCAL CODES. ELECTRICAL WIREWAY .125 ALUMINUM PAN POWER DISTRIBUTION BOARD BY FEDERAL HEATH SIGN SLOAN POWER SUPPLIES BY FEDERAL HEATH SIGN INSTALLED TO BOARD BY SIGN INSTALLER NOTE: POWER SUPPLY QUANTITY DEPENDENT ON SIGNAGE REQUIRED. INSTALLATION REQUIREMENT: power distribution board (pdb) to be mounted no more then 12” above ceiling to the bottom of the pdb. refer to design drawings for specific location of pdb. pdb to be mounted so that it is easily accessible from a step ladder. Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 1211 EXISTING LOOK MONUMENT ON LA QUINTA CENTER DRIVE NTS NEW LOOK MONUMENT ON LA QUINTA CENTER DRIVE NTS EXISTING LOOK MONUMENT ON AVENUE 47 NTS NEW LOOK MONUMENT ON AVENUE 47 NTS3'-6"8 1/2"3'-6"8 1/2"3'-6"10 3/4"3'-6"10 3/4"F G Boyd Hippenstiel Sandra Ramirez Virgo S. Aragones/CHC Store: #T1867 78935 US HWY 111 LA QUINTA , CA 92253 23-44769-10 22 February 2018 23-44769-10 1212 ANY DEVIATION FROM FEDERAL HEATH REQUIREMENTS MAY RESULT IN DAMAGE TO OR IMPROPER OPERATION OF SIGNAGE, CAUSING DELAYS AND ADDITIONAL COSTS. ELECTRICAL REQUIREMENTS Total: 0.0 Amps ( 1 ) 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. SIDE VIEW SCOPE OF WORK: MANUFACTURE AND INSTALL CHANNEL LOGO & LETTERS ACRYLIC FACED INT. ILLUM. "LOGO & LETTER SET" | LC -S W White Sloan White LED MATERIAL FINISH COLORS Returns Trimcap/Retainer Illumination WHITE 7328 White ATUGLAS Acrylic Faces A A D D E D D C B SIGN TYPE A B C D E SQ.FT.RETAINER AMPS CIRCUITS LL42/10 3/4 LC-S W 3'-6"4'-9"1'-2"10 3/4"7"1"16.625 F G& REMOVE EXISTING CHANNEL LOGO & LETTERS AND DISPOSE. FOUR (4) SETS REQ'D for TWO (2) MONUMENT SIGN PATCH AND PAINT C-45 SW 7033 BRAINSTORM BRONZE. CUSTOM SIZE T-1867 La Quinta, CA: Exterior Elevation Refresh February 20, 2018 Site PlanLA QUINTA CENTER DRIVEU S HW Y 1 1 1 AVENUE 47WASHINGTON ST(E) MONUMENT SIGN: REFURBISH RED BULLSEYE LOGO WITH NEW WHITE BULLSEYE LOGO AND LOWER CASE “target” CHANNELIZED LETTERING (E) MONUMENT SIGN: REFURBISH RED BULLSEYE LOGO WITH NEW WHITE BULLSEYE LOGO AND LOWER CASE “target” CHANNELIZED LETTERING NOTE (E) PYLON SIGN BACKGROUND: SITE SIGNS ARE RED WITH A LIGHT EARTH TONE BACKGROUND, UPDATE SIGNS TO BE WHITE WITH A DARK EARTH TONE BACKGROUND. (E) PYLON SIGN, TYP (E) BACKGROUNDCOLORS TO REMAIN SIGN ELEVATION - NTS SIDEFRONT REPAINTC-45 REPAINTC-45 C-45 SW 7033 BRAINSTORM BRONZE