Loading...
MBA 2016-0002 Cliff House (05.21.2018) 78-495 Calle Tampico La Quinta, CA 92253 760.777.7000 May 21, 2018 Mr. Dan Talant NOAA 4990 N. Harbor Dr. Suite 201 San Diego, CA 92106 SUBJECT: MODIFICATION BY APPLICANT 2016-0002 CLIFF HOUSE Dear Mr. Talant: The Design and Development Department has reviewed your request for a modification to the approved Plot Plan 89-417 for the existing Cliff House Restaurant located at 78250 Highway 111. The modifications include remodeling the existing bar and dining patios including adding a wood trellis, heaters, and lighting. The design does not result in additional square footage and will not change the building footprint of the existing Cliff House restaurant building. Additionally, it has been determined that said plan modifications are minor and will not result in a significant change in the project as approved by the decision-making authority. Therefore, the design modification is approved as shown on the attached exhibits, subject to the following condition of approval: 1. The applicant shall secure building permit approval (BCOM2018-0019) from the Building Division prior to the initiation of any work. Should you have questions, please contact me at 760-777-7069. Sincerely, Carlos Flores Associate Planner Attachments: 1. Site Plan CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-1 General Information.dwg 5-09-2018 - 1:03pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA········PLANNING APPROVAL ADMINISTRATIVE CASE# ____________________ EXHIBIT# ____________________ INITIAL cflores DATE 05/21/2018 2:37:11 PM MBA2016-0002 ¼CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-2 Site Plan.dwg 5-09-2018 - 1:03pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-3 Demo and Floor - Bar Patio.dwg 5-09-2018 - 1:03pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-4 RCP and Roof - Bar Patio.dwg 5-09-2018 - 1:03pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-5 Demo and Floor - McGinnis Patio.dwg 5-09-2018 - 1:04pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-6 RCP and Roof - McGinnis Patio.dwg 5-09-2018 - 1:04pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 O:\CLIFFHOUSE\2018 BAR PATIO RENOVATION\CD'S\SHEETS\A-7 Sections.dwg 5-09-2018 - 1:04pm (CassieR)No. C11956RENLIC E N SED ARCHITECTGA R Y W. NOGLESTATE OF CALI F O R NIA CLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 \\CGK-Server\Operations\01 Project\18017 - Cliffhouse Exterior Patio\Drawings\Sheets\P0.1 PLUMBING LEGEND, NOTES, SCHEDULES AND SYMBOLS.dwg 5-09-2018 - 9:23am (jmdamaso)cgkGROUPCONSULTING7968 ARJONS DRIVE SUITE A112SAN DIEGO, CA 92126T (858) 598-4860F (858) 244-1399WWW.CGK-CONSULTING.COMSIGNED: ________________________ENGINEER OF RECORDEXP. 03/20NA OE MTR TSAFEFOLCAI AEHCIN CE T RESIG D NO. M 3 5 8 0 7ERFOPISSORR IA L NEENENGIALM ICH A E L A.CARLOMAGNOPLUMBING LEGEND,NOTES, SCHEDULESAND SYMBOLSP0.1DESCRIPTIONGGSYMBOL ABBRPIPE UPUNIONPIPE CAPDIRECTION OF FLOWPIPE DOWNBUTTERFLY VALVEBALANCING VALVEBALL VALVEGLOBE VALVEP&TRVPRVSOVBFVBVHOSE BIBBSTRAINERCHECK VALVEFLOOR SINKPRESSURE GAUGEWALL CLEANOUTTHERMOMETERFLOOR DRAINFSRD/ODAD/DDIWRFCO/COTGFDWCOFDCPGHBFCWHABPRPBPCVROOF DRAIN & OVERFLOW ROOF DRAINAREA DRAIN OR DECK DRAININDIRECT WASTE RECEPTORPLUMBING LEGENDPIPE BRANCH - TOP CONNECTIONPIPE BRANCH - SIDE CONNECTIONGAS SHUT-OFF VALVE (PLUG TYPE)FLOOR CLEANOUT OR CLEANOUT TO GRADESHUT-OFF VALVE ON RISER OR DROPBACKFLOW PREVENTER (DOUBLE CHECK TYPE)REDUCED PRESSURE BACKFLOW PREVENTERPRESSURE & TEMPERATURE RELIEF VALVEPRESSURE REGULATOR / REDUCING VALVEPIPE BRANCH - BOTTOM CONNECTIONFIRE DEPARTMENT CONNECTIONFLEXIBLE PIPE CONNECTIONWATER HAMMER ARRESTERSHUT-OFF VALVE (GATE TYPE)REDUCER OR INCREASERNATURAL GAS PIPINGIEINVERT ELEVATIONBELOW FLOORBELOW GRADEVENT THRU ROOFPOINT OF CONNECTIONGALLONS PER MINUTEGALLONS PER HOURGALLONS PER FLUSHBUILDINGABOVE CEILINGCONNECTIONPSIGMBHBTUHGPHGPFGPMA/CLBLDGNIPCCONNB/FB/GVTRFFE(E)POC°FMINIMUMDEGREES FAHRENHEITMAXIMUMMANUFACTURERQUANTITYEXISTINGDRAWINGSTYPICALWATER COLUMNTYPWCMAXMINMFRQTY(E)DWGSARCHFPSFEET PER SECONDPOUNDS PER SQUARE INCH GAUGEBRITISH THERMAL UNITS PER HOURBRITISH THERMAL UNITS PER HOUR x 1OOOPIPING OR EQUIPMENT TO BE REMOVEDEXISTING PIPING (SEE PLANS FOR TYPE)ARCHITECT OR ARCHITECTURALNOT IN PLUMBING CONTRACTFINISHED FLOOR ELEVATIONPLUMBING GENERAL NOTES1. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AND SHALL NOTIFY ARCHITECT ANDOWNER OF ANY & ALL DISCREPANCIES PRIOR TO COMMENCING CONSTRUCTION.2. ALL PIPING AND EQUIPMENT SHALL COMPLY WITH THE LATEST IAPMO STANDARDS & ALLAPPLICABLE BUILDING CODES, LOCAL OR OTHERWISE.3. WASTE PIPING SHALL BE PITCHED AT A MINIMUM OF 1/4" INCH PER FOOT WHERE POSSIBLE. PIPINGGREATER THAN 4 INCHES IN DIAMETER ONLY, MAY BE PITCHED AT A MINIMUM OF 1/8" PER FOOT,AS REQUIRED, BY THE APROVAL OF THE ADMINSITRATIVE AUTHORITY.4. ALL EQUIPMENT GIVING OFF WASTE OR CONDENSATE ARE REQUIRED TO DRAIN INTO FLOOR SINKSOR OTHER APPROVED P-TRAPS.5. WALL HUNG FIXTURES SHALL BE SECURELY ATTACHED TO WOOD BLOCKING SECURELY FRAMEDIN.6. AIR CHAMBERS SHALL BE PROVIDED FOR EACH FIXTURE AT HOT AND COLD WATER CONNECTIONS.7. HOT WATER PIPING SHALL BE INSULATED WITH FIBERGLASS PIPE INSULATION WITH A VAPORBARRIER, AS REQUIRED FOR LOCAL WEATHER CONDITIONS TO PREVENT EXCESSIVE ENERGYLOSS. USE MIN. 1" INSULATION ON WATER PIPING.8. ALL NEW PIPING SHALL BE PRESSURE TESTED TO THE APPROVAL OF THE ADMINISTRATIVEAUTHORITY AND MINIMUM STANDARDS AS FOLLOWS:SANITARY PIPING: MIN. WATER PRESSURE 5 PSI FOR 15 MINUTES.WATER PIPING: MIN. WATER PRESSURE 120 PSI FOR 15 MINUTES.9. COLD & HOT WATER PIPING TO FIXTURES SHALL BE THOROUGHLY FLUSHED AND RINSED PRIOR TOPLACING IN SERVICE.10. JANITORIAL SINK FAUCETS SHALL BE PROTECTED WITH AN APPROVED BACKFLOW PREVENTIONDEVICES.11. CONNECTIONS BETWEEN COPPER OR BRASS PIPING WITH FERROUS MATERIALS SHALL BE MADEWITH APPROVED DIELECTRIC COUPLINGS.12. ALL ROOF PENETRATIONS SHALL BE FLASHED AND COUNTER FLASHED TO ENSURE A DURABLEWATERPROOF MEMBRANE.13. ALL PIPING SHALL BE SUPPORTED AT THE MINIMUM INTERVALS SHOWN BELOW:SIZE SUPPORT SPACING1/2" 6 FT3/4"8 FT1" 8 FT1-1/4"10 FTLARGER SIZES 10 FT14. ALL FLOOR, WALL OR GROUND CLEAN-OUTS SHALL BE INSTALLED IN WITH SUFFICIENT SPACE FORSERVICE AND IN COMPLETE ACCORDANCE WITH THE LOCAL BUILDING CODE REQUIREMENTS.15. ALL FLOOR MOUNTED SANITARY CLEAN-OUTS SHALL HAVE SKID-RESISTANT COVER PLATES.16. FOR THE PURPOSES OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLYDIAGRAMMATIC AND, ALTHOUGH SIZE AND LOCATION OF EQUIPMENT IS DRAWN TO SCALEWHEREVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL OF THECONTRACT DOCUMENTS, AND VERIFY THIS INFORMATION AT THE BUILDING SITE.17. DRAWINGS INDICATE REQUIRED SIZE AND TERMINATION OF PIPES AND DUCTWORK, AND SUGGESTPROPER ROUTES OF PIPING TO CONFORM TO THE STRUCTURE, TO AVOID OBSTRUCTIONS AND TOPRESERVE CLEARANCE. HOWEVER, IT IS NOT THE INTENTION TO INDICATE ALL NECESSARYOFFSETS AND IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL THE PIPINGAND DUCTWORK IN SUCH A MANNER AS TO CONFORM TO THE STRUCTURE, AVOIDOBSTRUCTIONS, PRESERVE HEADROOM, KEEP OPENINGS & PASSAGEWAYS CLEAR, & MAKE ALLEQUIPMENT REQUIRING INSPECTION, MAINTENANCE OR REPAIR, ACCESSIBLE WITHOUT FURTHERINSTRUCTIONS OR EXTRA COST TO THE OWNER.18. CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE WATER SUPPLIEDAPPLIANCES OR EQUIPMENT.PLUMBING EQUIPMENT SCHEDULEITEMFIXTUREMANUFACTURERAND MODELDESCRIPTIONSH-1SPACE HEATERDETROIT RADIANTRE-VERBER-RAY"DSCS-34"34,000 BTU/H, ETL ANSI Z83.26 CERTIFIED SPACE HEATER WITH RELIABLE SPARK IGNITION & WINDAND RAIN PROTECTED DESIGN. 24VAC NEC CLASS2 TRANSFORMER .65A. 1/2" NPT GAS CONNECTION.PIPING MATERIAL SCHEDULETYPEINSTALLATIONSTANDARDSG (NATURAL GAS)SCHEDULE 40 BLACK STEEL, THREADED JOINTS AND FITTINGS RATED FOR 150PSIGASTM A53, ASME B16.3STORM DRAINSOLID CORE PVC PIPE AND FITTINGASTM D 2665SCALE:1GAS RISER DIAGRAMN.T.S.GAS CALCULATIONTAGAPPLIANCECFHQUANTITYTOTALSH-1PATIO SPACE HEATER3417578(E)RG-1EXISTING HEAVY DUTY RANGE1051105(E)BR-1EXISTING BROILER1051105(E)FR-1EXISTING FRYER90190(E)CV-1EXISTING CONVECTION OVEN2101210(E)SH-1EXISTING PATIO SPACE HEATER3411374TOTAL:1462TOTAL DEVELOPED LENGTH OF LOW PRESSURE GAS PIPING = 300 FTGAS PIPING SYSTEM SIZED BASED ON 2013 CPC TABLE 1216.2(1)GAS PIPE MATERIAL: SCHEDULE 40 ASME A-53 BLACK STEEL PIPEFOR CONNECTION DETAIL TO UNIT, SEE #1/P0.1GAS & WATERTIGHT SLEEVE THROUGHBASEMENT WALL, ENCASE IN PROTECTIVESLEEVE PER 2016 CPC SECTION 1210.1.5RUN UNDERGROUND GAS PIPING ENCASEDWITHIN APPROVED CONDUIT PER 2016 CPCSECTION 1210.1.6 & 1210.1.6.1PLUMBING FIXTURE SCHEDULEITEMFIXTUREMIN. BRANCH SIZEDESCRIPTIONCW HW V SDAD-1AREA DRAIN---3"ZURN Z158 10" PROMENADE DECK DRAIN WITH 3" OUTLET.1-1/4"G136 CFH1-1/4"G136 CFH1-1/2"G272 CFHSCALE:2EQUIPMENT GAS CONNECTION DETAILN.T.S. (E)RG-1(E)BR-1(E)CV-1(E)FR-1(105)(105)(210)(90)POC OF 3"G TO (E)GASMETER/REGULATORASSEMBLY(E)2"G(646)(E)2"G DN3"G (1,0 3 8 )POC OF 2-1/2"G TO (E)2"G3"G(1,684)(E)2"G(646)(E)2"G(646)GAS PIPING ROUTED IN CEILINGSPACE OF BASEMENTSH1SH1SH1SH1SH1SH12"G(272)1-1/4"G(136)1"G(68)3/4"G(34)3/4"G TO SH-1(TYP. 12)(34)1"G(68)1-1/4"G(204)(E)2"G RISER(374 CFH)(E)2"G(374)SH1SH1SH1SH1SH1SH1SH1SH1POC OF 1-1/2"G TO (E)2"G(272 CFH)GAS PIPING INSTALLED ON TRELLIS,COORDINATE WITH GENERAL CONTRACTOR3/4"G TO SH-1(TYP. 8)1-1/4"G1"G 3/4"G1-1/4"G1-1/4"G 1"G 3/4"GCLIFFHOUSE / PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 92253 \\CGK-Server\Operations\01 Project\18017 - Cliffhouse Exterior Patio\Drawings\Sheets\P1.0 PLUMBING SITE PLAN.dwg 5-09-2018 - 9:23am (jmdamaso)cgkGROUPCONSULTING7968 ARJONS DRIVE SUITE A112SAN DIEGO, CA 92126T (858) 598-4860F (858) 244-1399WWW.CGK-CONSULTING.COMSIGNED: ________________________ENGINEER OF RECORDEXP. 03/20NA OE MTR TSAFEFOLCAI AEHCIN CE T RESIG D NO. M 3 5 8 0 7ERFOPISSORRIA L NEENENGIALM ICH A E L A.CARLOMAGNOPLUMBING SITE PLANP1.0SCALE:1PLUMBING SITE PLAN1/8 = 1'-0" T:\2018\2018-0031 cliffhouse bar patio\acad files\E-0.1.dwg 5-08-2018 - 4:27pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-0031SHEET INDEXSHEET NUMBERSHEET TITLEE-0.1COVER SHEETE-0.2LIGHTING SCHEDULE & CONTROL DETAILE-0.3TITLE 24 FORMSE-0.4TITLE 24 FORMSE-1.1DEMO PLANE-2.1LIGHTING PLANE-4.1SINGLE LINE DIAGRAMMEQUIPMENT LEGENDHEAVY DUTY NON-FUSED DISCONNECTHEAVY DUTY FUSED DISCONNECTMOTOR STARTER, HOA, AUX CONTACTS, CPT, PILOT LIGHTSCOMBINATION MOTOR STARTER, HOA, AUX CONTACTS, CPT, PILOTLIGHTS, WITH FUSED DISCONNECT SWITCHMECHANICAL EQUIPMENT TAGMOTOR RATED SWITCHSURFACE MOUNTED PANEL BOARD OR ELECTRICAL CABINETDISTRIBUTION SWITCHBOARD OR PANEL BOARDLIGHT FIXTURE DESIGNATIONLIGHTING BRANCH CIRCUITRELAY DESIGNATION IN LIGHTINGCONTROL PANELFLUSH MOUNTED PANEL BOARD OR ELECTRICAL CABINETVARIABLE FREQUENCY DRIVE. CONFIRM INTEGRAL DISCONNECTINGMEANS WITH MECHANICALF1HL1-13(R1)AHU1FVFDTTRANSFORMEREMERGENCY POWER OFF BUTTONEPOSFDSMOKE FIRE DAMPERMOTORSIGNAL LEGENDFLUSH MOUNTED TELEVISION OUTLET MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NWIRELESS ACCESS POINTFLUSH MOUNTED TELECOM OUTLET MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.N. PROVIDE 1"C. TO ACCESSIBLE CEILINGSPACE WITH PULL STRING, U.O.N.SURFACE MOUNTED TELECOM OUTLET MOUNTED AT +15" AFF TOBOTTOM OF BOX U.ON. PROVIDE 1"C. TO ACCESSIBLE CEILINGSPACE WITH PULL STRING, U.O.N.CEILING MOUNTED TELECOM OUTLETPUSH BUTTONBUZZERBELLWALL MOUNTED SPEAKERCEILING MOUNTED SPEAKERTVWAPFLUSH FLOOR BOX WITH TELECOM OUTLETFIRE RATED POKE THRU WITH TELECOM OUTLETBBSSFLUSH MOUNTED WALL PHONE OUTLET MOUNTED AT +44" AFF TOTOP OF BOX U.O.NWSINGLE LINE LEGENDELECTRONIC METERING UNITCURRENT TRANSFORMERPOTENTIAL TRANSFORMERDRAWOUT CIRCUIT BREAKERAMP FRAMEAMP TRIPPOLE CONFIGURATIONELECTRONIC TRIP FUNCTIONSFUSETRANSFORMER100AF100AT3LSIGFUSED SWITCHAMP SWITCHAMP FUSEPOLE CONFIGURATION100AS100AF3CIRCUIT BREAKERAMP FRAMEAMP TRIPPOLE CONFIGURATIONELECTRONIC TRIP FUNCTIONS100AF100AT3LSIGGROUNDING ELECTRODEENCLOSED CIRCUIT BREAKERAMP FRAMEAMP TRIPPOLE CONFIGURATIONELECTRONIC TRIP FUNCTIONS100AF100AT3LSIGCNORMALLY OPEN CONTACTNORMALLY CLOSED CONTACTCOILSHUNT TRIPSTSOLID STATESSFEEDER TAGXXXXAUTOMATIC TRANSFER SWITCHPACKAGE ENGINE GENERATORPANEL BOARDPANELHL1TRANSIENT VOLTAGE SURGE SUPPRESSIONTVSSM+-+-STRINGER INVERTER+-PHOTOVOLTAIC PANEL (PV PANEL)PHOTOVOLTAIC LEGENDDC TO AC STRING INVERTERPOTENTIAL INDUCED DEGRATION (PID) ENERGY BALANCER CABINETPHOTOVOLTAIC MODULE PANEL (PV PANEL)PIDPHOTOVOLTAIC ARRAY (PV ARRAY)STRING NUMBER DESIGNATIONINVERTER NUMBER DESIGNATIONS#.#WIRING LEGENDRACEWAY EXPOSEDRACEWAY TURNED UPRACEWAY TURNED DOWNRACEWAY CAPPED AND STUBBED.PROVIDE PERMANENT GROUNDMARKER FOR UNDERGROUND INSTALLATIONSBRANCH CIRCUIT RACEWAY CONCEALED IN WALL OR CEILINGBRANCH CIRCUIT RACEWAY CONCEALED IN FLOOR ORUNDERGROUNDBRANCH CIRCUIT RACEWAY HOME RUN BACK TO ELECTRICALEQUIPMENT AS NOTEDL1-1BRANCH CIRCUIT RACEWAY WITH 3#12, 1#12N, 1#12GND, 3/4"C.MAXIMUM THREE BRANCH CIRCUITS PER HOME RUN, U.O.N.BRANCH CIRCUIT RACEWAY WITH 3#10, 1#10N, 1#10GND, 3/4"C.MAXIMUM THREE BRANCH CIRCUITS PER HOME RUN, U.O.N.#10CABLE TRAYPOINT OF CONNECTION TO EQUIPMENTBRANCH CIRCUIT RACEWAY TO BE DEMOLISHSURFACE MOUNTED WIRE MOLD RACEWAY SYSTEM.X = 1, 2 OR 3 CHANNEL RACEWAYWMXCONTROL LEGENDSURFACE MOUNTED SPST SWITCH MOUNTED AT +48" AFF TO TOP OFBOX U.O.NFLUSH MOUNTED SINGLE POLE STANDARD TOGGLE SWITCHMOUNTED AT +48" AFF TO TOP OF BOX U.O.N. LETTERING INDICATESQUANTITY OF SWITCHES AND DEVICES TO BE CONTROLLED.XXD = DIMMING SWITCHK = KEYED SWITCHP = PILOT LIGHT SWITCHR = MOMENTARY CONTACT SWITCHT = TIMER SWITCH3 = THREE WAY SWITCHFLUSH INFRARED WALL OCCUPANCY SENSOR SINGLE BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NOCFLUSH INFRARED WALL OCCUPANCY SENSOR DUAL BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NOCabSURFACE INFRARED WALL OCCUPANCY SENSOR SINGLE BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NSURFACE INFRARED WALL OCCUPANCY SENSOR DUAL BUTTONMOUNTED AT +48" AFF TO TOP OF BOX U.O.NabOCOCXXU = ULTRA SONIC OCCUPANCY SENSORDT = DUAL TECHNOLOGY OCCUPANCY SENSOROCCEILING MOUNTED INFRARED OCCUPANCY SENSOROCFLUSH MOUNTED OVERRIDE SWITCH STATION MOUNTED AT +48" AFFTO TOP OF BOX U.O.N. BUTTON CONFIGURATION AS NOTED PERFLOOR PLANSURFACE MOUNTED OVERRIDE SWITCH STATION MOUNTED AT +48"AFF TO TOP OF BOX U.O.N. BUTTON CONFIGURATION AS NOTED PERFLOOR PLANPHOTOCELL MOUNTED AND ORIENTATED AS NOTED ON FLOOR PLANOOPCDLCEILING MOUNTED DAY LIGHT SENSORABBREVIATIONS AND DESCRIPTIONSA / AMPAMPEREABVABOVEADAAMERICAN WITH DISABILITIES ACTAFAMPERE FRAME, AMPERE FUSEAFF / A.F.F. ABOVE FINISH FLOORAFG, A.F.G. ABOVE FINISH GRADEAWG AMERICAN WIRE GAUGEAIC / A.I.C. AMPERE INTERRUPTING CAPACITYASAMPERE SWITCHATAMPERE TRIPATS AUTOMATIC TRANSFER SWITCHAVG AVERAGEBKR BREAKERBLDG BUILDINGBRBRANCHCCONDUITCATV CABLE TELEVISIONCBCIRCUIT BREAKERCBC CALIFORNIA BUILDING CODECEC CALIFORNIA ELECTRIC CODECFC CALIFORNIA FIRE CODECIRC / CKT CIRCUITCLCENTER LINECLG CEILINGCO / C.O. CONDUIT ONLYCOMM COMMUNICATIONSCSFM CALIFORNIA STATE FIRE MARSHALLCTCONTROL TRANSFORMERCONN CONNECTEDCPT CONTROL POWER TRANSFORMERCTR CENTERDET DETAILDIST DISTRIBUTIONDPDISTRIBUTION PANEL(D)DEMOLISHDISC DISCONNECTDWG DRAWINGDIADIAMETERDIM DIMENSIONEMTELECTRICAL METALLIC TUBINGEPEXPLOSION PROOFEMEMERGENCYEQP EQUIPMENT(E)EXISTINGELEC ELECTRICALEMS EMERGENCY MANAGEMENT CONTROL SYSTEMENTELECTRICAL NON-METALLIC TUBINGEPO / E.P.O EMERGENCY POWER OFFEFEXHAUST FANEGEQUIPMENT GROUNDEOL END OF LINE RESISTORFACP FIRE ALARM CONTROL PANELFLFLOORFATC FIRE ALARM TERMINAL CABINETFAFIRE ALARMFLA FULL LOAD AMPSFT / ' FEETFINFINISHG / GND GROUNDGFCI GROUND FAULT CIRCUIT INTERRUPTERGFP GROUND FAULT PROTECTIONGEC GROUNDING ELECTRODE CONDUCTORH / HGT HEIGHTHOA HAND OFF AUTOHPHORSEPOWERHACR HEATING AIR CONDITIONING REFRIGERATIONHVAC HEATING, VENTILATING AND AIR CONDITIONINGHPS HIGH PRESSURE SODIUMHIDHIGH INTENSITY DISCHARGEICINTERCOMIDFINTERMEDIATE DISTRIBUTION FRAMEIN / " INCHESIMC INTERMEDIATE METAL CONDUITIPINTERNET PROTOCOLIGISOLATED GROUNDJB / JBOX JUNCTION BOXKAIC KILOAMPERE INTERRUPTING CAPACITYKVKILOVOLTKVAKILOVOLT AMPEREKWKILOWATTKWH KILOWATT HOURLTG / LTS LIGHTINGLVLOW VOLTAGELFLINEAR FEETKCMIL / MCM THOUSAND CIRCULAR MILSMAX MAXIMUMMDF MAIN DISTRIBUTION FRAMEMECH MECHANICALMHMANHOLEMTDMOUNTEDMTG MOUNTINGMIN MINIMUMMOCP MAXIMUM OVERCURRENT CIRCUIT PROTECTIONMCA MINIMUM CIRCUIT AMPERESM.H. METAL HALIDEMCB MAIN CIRCUIT BREAKERMLO MAIN LUGS ONLYMMETERMVMERCURY VAPORMCC MOTOR CONTROL CENTERMFRMANUFACTURERNCNORMALLY CLOSEDNFPA NATIONAL FIRE PROTECTION ASSOCIATIONNICNOT IN CONTRACTNONORMALLY OPENNO. / # NUMBERNEC NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICAL MFR ASSOCIATIONNFNON-FUSEDNLNIGHT LIGHTNTS NOT TO SCALEOCON CENTEROFCI OWNER FURNISH, CONTRACTOR INSTALLEDPPOLEPBPULL BOXPFPOWER FACTORPAPUBLIC ADDRESSPH / øPHASEPNL PANELPRIMARYOVER 600 VOLTSPCPHOTOCELLPDUPOWER DISTRIBUTION UNITPROVIDE FURNISH, INSTALL AND/OR CONNECTPTPOTENTIAL TRANSFORMERPVC POLYVINYL CHLORIDEREQD REQUIREDREQT(S) REQUIREMENT(S)RMROOMRMS ROOT MEAN SQUARERGS RIGID GALVANIZED STEEL CONDUITRECEPT RECEPTACLESHT SHEETSWSWITCHSWBD SWITCHBOARDSTC SIGNAL TERMINAL CABINETSCC SHORT CIRCUIT CURRENTSFD SMOKE FIRE DAMPERSECONDARY 600 VOLTS AND LESSSQSQUARETELTELEPHONETYPTYPICALTCTIMECLOCKTEL/DAT TELEPHONE AND DATATVTELEVISIONTVSS TRANSIENT VOLTAGE SURGE SUPPRESSIONULUNDERWRITERS LABORATORIESUON / U.O.N. UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLYVVOLTAGEVAVOLT AMPERESVDVOLTAGE DROPVAV VARIABLE AIR VOLUMEWWATTAGE OR WIREWPWEATHERPROOFWAP WIRELESS ACCESS POINTXFMR TRANSFORMERX / (X) EXISTINGXL / (XL) EXISTING TO BE RELOCATEDXR / (XR) EXISTING TO BE REMOVEDXN / (XN) EXISTING NEW LOCATION%ZPERCENTAGE IMPEDANCEWTWEIGHTWHWATER HEATERVFDVARIABLE FREQUENCY DRIVEUGPS UNDERGROUND PULL SECTIONTEMP TEMPERATURE OR TEMPORARYSWGR METAL CLAD SWITCHGEARSPEC SPECIFICATIONSREC RECESSEDREFRIG REFRIGERATORQTY QUANTITYPWRPOWERN / NEUT NEUTRALLBS POUNDSKSKNEE SPACEHRHOUR OR HOME RUNHZHERTZGCGENERAL CONTRACTORGALV GALVANIZEDECELECTRICAL CONTRACTORCUCOPPERCCTV CLOSED CIRCUIT TELEVISIONALALUMINUMACALTERNATING CURRENTA/CAIR CONDITIONINGDCDIRECT CURRENTEAEACHEXO DISCONNECT SWITCHSECURITY LEGENDALARM CONTACTELECTRIC DOOR STRIKEDOOR CONTACTREMOTE DOOR RELEASEELECTRONIC LOCKVIBRATION DETECTORCARD READERKEYPADACRKPGLASS BREAKGBMOTION SENSORMSESDCDRDOOR BREACH ALARMPANIC BUTTON / DURESS ALARMREQUEST TO EXITREXELECTRONIC HOLD OPENEHOELECTRONIC PANIC HARDWAREEPHELECTRONIC MAGNETIC LOCKEMLFIXED POSITION VIDEO CAMERAELVDDAPBPAN, TILT, ZOOM VIDEO CAMERAPTZFLUSH MOUNTED HALF HOT DUPLEX RECEPTACLE MOUNTED AT +15"AFF TO BOTTOM OF BOX U.O.NXXHALF SHADED WIRING INDICATES CONTROLLEDRECEPTACLE PER TITLE 24 SECTION 130.5(d)POWER LEGENDFLUSH MOUNTED DUPLEX RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NFLUSH MOUNTED QUAD RECEPTACLE MOUNTING HEIGHT TOBOTTOM OF BOX PER ARCHITECT ELEVATIONSURFACED MOUNTED DUPLEX RECEPTACLE MOUNTED AT +15" AFFTO BOTTOM OF BOX U.O.NSURFACE MOUNTED QUAD RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NFLUSH MOUNTED SINGLE RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NSURFACE MOUNTED SINGLE RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NCEILING MOUNTED DUPLEX RECEPTACLECEILING MOUNTED QUAD RECEPTACLEFLUSH FLOOR BOX WITH DUPLEX RECEPTACLEFLUSH FLOOR BOX WITH QUAD RECEPTACLEFLUSH FLOOR BOX WITH COMBINATION DUPLEX RECEPTACLE ANDDATA OUTLETFLUSH FLOOR BOX WITH COMBINATION QUAD RECEPTACLE ANDDATA OUTLETFIRE RATED POKE THRU WITH DUPLEX RECEPTACLEFIRE RATED POKE THRU WITH QUAD RECEPTACLEFIRE RATED POKE THRU WITH DUPLEX RECEPTACLE AND DATAOUTLETFIRE RATED POKE THRU WITH QUAD RECEPTACLE AND DATAOUTLETXXFLUSH MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEMOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.NSURFACE MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEMOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.NXX-XXXXX-XXXFLUSH MOUNTED JUNCTION BOX MOUNTED AT +15" AFF TO BOTTOMOF BOX U.O.NSURFACE MOUNTED JUNCTION BOX MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.NFLUSH FLOOR MOUNTED JUNCTION BOXCEILING MOUNTED JUNCTION BOXJJJJGFCIIGSHACGROUND FAULT CIRCUIT INTERRUPTERISOLATED GROUNDSURGE SUPPRESSORHORIZONTAL MOUNTEDMOUNT ABOVE COUNTER PERARCHITECT ELEVATIONPROVIDED WITH INTREGRAL USBPORTSRECEPTACLE CONTROLLED PER TITLE24 2013 SECTION 130.5(d)CLOCK TYPE====CEILING MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEXX-XXXFLOOR MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLEXX-XXX==RC=CFLUSH MOUNTED DUPLEX RECEPTACLE MOUNTING HEIGHT TOBOTTOM OF BOX PER ARCHITECT ELEVATIONSURFACED MOUNTED DUPLEX RECEPTACLE MOUNTED AT COUNTERLEVEL PER ARCHITECT ELEVATIONSURFACE MOUNTED QUAD RECEPTACLE MOUNTING TO BOTTOM OFBOX PER ARCHITECT ELEVATIONFLUSH MOUNTED QUAD RECEPTACLE MOUNTED AT +15" AFF TOBOTTOM OF BOX U.O.N=USBRECEPTACLE POWER PACK MOUNTED IN ACCESSIBLE CEILINGSPACE FOR AUTOMATIC CONTROL OF RECEPTACLE DEVICERC1. CONTRACTOR TO OBTAIN PERMISSION FOR ACCESS TO THE SITEFROM THE OWNER OR DESIGNATED OWNER REPRESENTATIVE TOVISIT THE SITE INCLUDING ALL AREAS OF WORK PRIOR TO BID.CONTRACTOR TO BE FAMILIARIZED WITH EXISTING CONDITIONS,VERIFY SAID CONDITIONS, DIMENSIONS, AND ROUTINGS PRIOR TOSTART OF CONSTRUCTION. REPORT ANY DISCREPANCIES TOOWNER / ARCHITECT / ENGINEER WITHIN 48 HOURS OFDISCREPANCIES FOUND.2. CONTRACTOR SHALL CONFIRM ACCURACY OF PANEL BOARDINFORMATION PRIOR TO START OF WORK. REPORT ANYDISCREPANCIES TO OWNER / ARCHITECT / ENGINEER WITHIN 48HOURS OF DISCREPANCIES FOUND.3. ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED.4. ALL AREAS OUTSIDE THE SCOPE OF WORK SHALL BE PROTECTEDIN PLACE AND REMAIN INTACT, U.O.N.5. CONTRACTOR TO COORDINATE WITH OWNER ANY SHUTDOWN OFELECTRICAL EQUIPMENT WITH 7 DAYS NOTIFICATION.CONTRACTOR TO INCLUDE OFF HOURS IN PRICING FOR THISWORK.6. ALL ELECTRICAL MATERIAL AND EQUIPMENT SHALL BE NEWBEARING A UL LISTING OR ACCEPTABLE NRTL LISTING FROM THELOCAL AREA JURISDICTION.7. CONTRACTOR SHALL COMPLY WITH THE CURRENT VERSION OFTHE CALIFORNIA ELECTRICAL CODE 2016, STATE, LOCAL CODES,ORDINANCES, AND REGULATIONS.8. WORK SHALL BE PERFORMED IN A SAFE MANNER AND NOTDISTURB OR AFFECT EXISTING BUILDING UTILITIES, OCCUPANTS,OR FINISHES WITHOUT PRIOR NOTICE AND APPROVAL FROMOWNER.9. ALL CONDUIT RUN SHALL BE FIELD COORDINATED, LOCATECONDUITS CLEAR OF OTHER TRADES, DOOR ACCESS, OR OTHEROBSTRUCTIONS. COORDINATE CONDUIT RUNS WITH OTHERTRADES PRIOR TO COMMENCEMENT OF WORK.10. RUN ALL CONDUITS CONCEALED IN CEILING SPACES, U.O.N. TO BESURFACE MOUNTED. ALL CONDUIT PATHWAYS MUST MAINTAIN 6INCHES CLEAR OF SOURCES OF HEAT, SUPPORT CONDUITS FROMSTRUCTURE.11. ALL BRANCH CIRCUITS TO BE PROVIDED WITH SEPARATE GREENGROUND INSULATED CONDUCTOR.12. ALL BRANCH CIRCUITS TO BE PROVIDED WITH SEPARATE WHITENEUTRAL INSULATED CONDUCTOR. SHARED NEUTRAL ISACCEPTABLE IF COMMON HANDLE TIE CIRCUIT BREAKER AREUTILIZED TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDEDCONDUCTORS PER NEC 210.4(B).13. PROVIDE IDENTIFICATION TAGS FOR ALL WIRING, INSTALL TAGS ATEND OF RUNS, INTERMEDIATE PULL BOXES, JUNCTION BOXES,CABINETS, ETC.14. BRANCH CIRCUIT VOLTAGE DROP NOT TO EXCEED 3% FROMPANEL BOARD SOURCE.15. LABEL ALL CIRCUIT BREAKERS IN ALL ELECTRICAL DISTRIBUTIONPANELS AND SWITCHBOARDS. PROVIDE TYPE WRITTEN CIRCUITDIRECTORY CARDS FOR ANY PANEL BOARD HAVING CIRCUITMODIFICATIONS.16. PROVIDE P-TOUCH LABELS ON ALL NEW OUTLETS, RACKS, PLUGMOLD, AND SWITCHES.17. ALL CONDUITS PENETRATING ELECTRICAL/MECHANICAL SPACESOF RATED WALLS SHALL BE SEALED AND FIRE STOPPED.18. ALL ELECTRICAL PENETRATIONS INTO COOLER OR FREEZER UNITSSHALL BE SEALED PER SECTION 300-7 OF THE NEC.GENERAL PROJECT NOTES LUMINAIRE SCHEDULECALLOUT SYMBOLLAMPDESCRIPTIONBALLASTMOUNTINGMODELINPUTWATTSVOLTSNOTE 1TOTALLUMENSKELVIN QUANTITYF1(1) 9.5W LEDLED OUTDOOR WALL SCONCE LIGHT FIXTURE,VERTICAL STEEL BAR SHIELDING THE GLASSTUBE, 19" FORGED VERTICAL BARS, ROBUSTCOASTAL OUTDOOR FINISH, DARK SMOKEFINISH WITH OPAL GLASS.0-10V DIMMING WALLHUBBARDTON FORGEFORGED VERTICAL BARSOUTDOOR SCONCE9.5120V 1P 2W8002700K 16F2(1) 13.2W LEDLED FLOODLIGHT FIXTURE, CAST ALUMINUMCONSTRUCTION WITH HEAT DISSIPATING FINS,TEXTURED TEMPERED GLASS LENS,ADJUSTABLE SWIVEL, DARK BRONZE CORRRESISTANT POWDER COAT PAINT FINISH, WETLOCATION LISTED.ELV DRIVER SURFACEHUBBELL LIGHTINGCOLT MINI MBUL SERIES13.2120V 1P 2W ELV DRIVER TO BE IN ACONCEALED, VENTILATED ANDACCESIBLE LOCATION.11153000K 6F3(1) 7W LEDLOW VOLTAGE STRAND LED LIGHT FIXTURE,POLYCARBONE GLOBE, STANDARD OUTPUT,24" SPACING INTERVALS, GLOBE FINISH ANDWIRE COLOR BY ARCHITECT.ELV DRIVER SURFACETIVOLI LIGHTINGLITESPHERE SERIES60120V 1P 2W APPROXIMATE LENGTHS 60' AND63' LF, PROVIDE EXTRA LEADWIRE AND 60W 120V ELV DRIVER.ELV DRIVER TO BE IN ACONCEALED, VENTILATED ANDACCESIBLE LOCATION.2822700K 2F4(1) 20W LEDWALL SCONCE LED LIGHT FIXTURE0-10V DIMMING WALLTBD20120V 1P 2W0TBD2LIGHT FIXTURE SCHEDULE NOTES:1.) QUANTITY COLUMN IS SHOWN FOR REFERENCE ONLY, TOTAL FIXTURE COUNTS ON PROJECT. CONTRACTOR TO CONFIRM COUNTS PRIOR TO ORDER.T:\2018\2018-0031 cliffhouse bar patio\acad files\E-0.2.dwg 5-08-2018 - 4:27pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-0031SCALE: NONE2LIGHTING CONTROL DETAILSCALE: NONE1LIGHTING SCHEDULEA3C9B6174285D#*0The Ethernet Interface Module (EIM) andWireless Ethernet Interface Module (WEIM)may be connected to any lighting control panein the system using the RS-232 cable included120VAC wall transformer includedEnd user computerscan program any lighting controlpanel via the Wireless Ethernet Interface Module (WEIM)using the Keeper Enterprise software.4 low voltage inputs(Momentary, Maintained, Alternate Actionswitches, occupancy sensors and Photocells)Each input is software programmable tocontrol any relay or group of relays.TypicalPhotocellfor On/Off controlTypicalOccupancy Sensorfor On/Off controlLighting control panel power supply:Voltage specific transformer. Specify 120VAC or 277VACfor the transformer voltage.Typical relay wiring:LineLoad ALineLoad BLineLoad CLineLoad DStandard relay informationQty 4 - 20 amp 120/277VAC single pole relaysAvailable normally openIndividual status LED manual overrides10 AWG maximum wire size10 million operations3 year warranty T:\2018\2018-0031 cliffhouse bar patio\acad files\E-0.3.dwg 5-08-2018 - 4:27pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-00315/8/20182PATIO 1/DINING AREADIMMING/ASTRONOMICAL TIME CLOCK2PATIO 2/DINING AREADIMMING/ASTRONOMICAL TIME CLOCK T:\2018\2018-0031 cliffhouse bar patio\acad files\E-0.4.dwg 5-08-2018 - 4:28pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-00315/8/20185/8/2018 12ALL ELECTRICAL DEVICES ARE EXISTING TO BE DEMOLISHED,U.O.N.DEMOLISH CONDUIT AND CONDUCTORS BACK TO SOURCEPANEL OR NEAREST EXISTING TO REMAIN JUNCTION BOXSERVING OTHER NOT IN SCOPE AREAS.CONTRACTOR TO FIELD VERIFY BRANCH CIRCUITRY PRIORTO COMMENCEMENT OF WORK.CONTRACTOR TO MAINTAIN CIRCUITRY CONTINUITY TOEXISTING SPACE OUTSIDE THIS SCOPE OF WORK.SEE ARCHITECTURAL SHEETS FOR ADDITIONAL DEMOLITIONREQUIREMENTS.ELECTRICAL CONTRACTOR TO MAKE EXISTING ELECTRICALSYSTEM SAFE FOR DEMO CONTRACTOR. ELECTRICALCONTRACTOR TO IDENTIFY CONDUIT SYSTEMS THAT ARE TOREMAIN AND CAREFULLY WALK WITH DEMO CONTRACTOREXPLAINING WHAT NEEDS TO STAY. IT IS THE DEMOCONTRACTOR AND GENERAL CONTRACTORSRESPONSIBILITY TO SET THIS MEETING UP AND MAKE SURETHAT THE COMMUNICATION ON WHAT STAYS IS CRYSTALCLEAR. ITEMS THAT STAY (FEEDERS TO PANELS ETC)SHOULD BE CLEARLY MARKED ON SITE WITH RED PAINT.ANYTHING MARKED RED SHALL NOT BE DEMO OR REMOVED.1.GENERAL NOTES:SCOPE OF DEMOLITION WORK.EXISTING AREA TO REMAIN. NO NEW SCOPE OF WORK.KEY NOTES:12.3.4.5.6.2112ALL ELECTRICAL DEVICES ARE EXISTING TO BE DEMOLISHED,U.O.N.DEMOLISH CONDUIT AND CONDUCTORS BACK TO SOURCEPANEL OR NEAREST EXISTING TO REMAIN JUNCTION BOXSERVING OTHER NOT IN SCOPE AREAS.CONTRACTOR TO FIELD VERIFY BRANCH CIRCUITRY PRIORTO COMMENCEMENT OF WORK.CONTRACTOR TO MAINTAIN CIRCUITRY CONTINUITY TOEXISTING SPACE OUTSIDE THIS SCOPE OF WORK.SEE ARCHITECTURAL SHEETS FOR ADDITIONAL DEMOLITIONREQUIREMENTS.ELECTRICAL CONTRACTOR TO MAKE EXISTING ELECTRICALSYSTEM SAFE FOR DEMO CONTRACTOR. ELECTRICALCONTRACTOR TO IDENTIFY CONDUIT SYSTEMS THAT ARE TOREMAIN AND CAREFULLY WALK WITH DEMO CONTRACTOREXPLAINING WHAT NEEDS TO STAY. IT IS THE DEMOCONTRACTOR AND GENERAL CONTRACTORSRESPONSIBILITY TO SET THIS MEETING UP AND MAKE SURETHAT THE COMMUNICATION ON WHAT STAYS IS CRYSTALCLEAR. ITEMS THAT STAY (FEEDERS TO PANELS ETC)SHOULD BE CLEARLY MARKED ON SITE WITH RED PAINT.ANYTHING MARKED RED SHALL NOT BE DEMO OR REMOVED.1.GENERAL NOTES:SCOPE OF DEMOLITION WORK.EXISTING AREA TO REMAIN. NO NEW SCOPE OF WORK.KEY NOTES:12.3.4.5.6.2T:\2018\2018-0031 cliffhouse bar patio\acad files\E-1.1.dwg 5-08-2018 - 4:28pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-0031SCALE:NORTH1DEMO PLAN - MCGINNIS PATIO1/4" = 1'-0"SCALE: NONEKEYPLANNONESCOPE OF WORKDETAIL 2SCALE:NORTH2DEMO PLAN - BAR PATIO1/4" = 1'-0"SCOPE OF WORKDETAIL 1 CFCFF1F1F1F1F1F1F1F1CFF2F2F2F2JJJJJJJJJ2626262828282628282(TYP OF 9)3F33D2LC-26,282LC-302LC56JJ78J42LC-321CFF1F11. CONTRACTOR TO MAINTAIN CIRCUITRY CONTINUITY TOEXISTING SPACE OUTSIDE THIS SCOPE OF WORK.2. DO NOT SWITCH EXIT SIGNS UNITS OR LIGHT FIXTURESLABELED "NL" (ON CONTINUOUSLY).3. "F1" FIXTURE TO BE COLUMN AND WALL MOUNTED.COORDINATE MOUNTING OF FIXTURE WITH ARCHITECT PRIORTO ROUGH-IN.4. "F2" FIXTURE TO BE TOP MOUNTED TO BEAMS. COORDINATEMOUNTING OF FIXTURE WITH ARCHITECT PRIOR TO ROUGH-IN.5. "F3" FIXTURE TO BE TIGHTLY MOUNTED TO UNDERSIDE OFBEAMS. COORDINATE MOUNTING OF FIXTURE WITH ARCHITECTPRIOR TO ROUGH-IN.6. FANS TO BE MOUNTED TO UNDERSIDE OF BEAMS.COORDINATE MOUNTING OF FAN WITH ARCHITECT PRIOR TOROUGH-IN.GENERAL NOTES:EXISTING AREA TO REMAIN. NO NEW SCOPE OF WORK.COORDINATE POINT OF CONNECTION TO OVERHEAD UNITHEATERS WITH MECHANICAL CONTRACTOR.PROVIDE #10 POWER BRANCH CIRCUIT CONDUCTORS.APPROXIMATE LOCATION OF ELV DRIVERS. TO BE INSTALLED IN ACONCEALED, VENTILATED AND ACCESSIBLE LOCATION. PROVIDEEXTRA LEAD WIRE.EXISTING ELECTRICAL PANELBOARD TO REMAIN AT SECONDFLOOR.CIRCUIT ROUTED THRU ASTRONOMICAL TIME CLOCK.APPROXIMATE LOCATION OF HEATER REMOTE CONTROL PANEL.COORDINATE LOCATION WITH ARCHITECT PRIOR TO ROUGH IN.APPROXIMATE LOCATION OF NEW LCP PANEL WITHASTRONOMICAL TIME CLOCK.KEY NOTES:123456782LAMSBJJJJJJJJ1231CFCFCFCF2LA-1288882(TYP OF 8)101010102LA-8,10F1F1F1F1F1F1JDJJ856F2F2F1F1F3F4F42LA-14791010JJ1111J2LA-402LA-42121. CONTRACTOR TO MAINTAIN CIRCUITRY CONTINUITY TOEXISTING SPACE OUTSIDE THIS SCOPE OF WORK.2. DO NOT SWITCH EXIT SIGNS UNITS OR LIGHT FIXTURESLABELED "NL" (ON CONTINUOUSLY).3. "F1" FIXTURE TO BE COLUMN AND WALL MOUNTED.COORDINATE MOUNTING OF FIXTURE WITH ARCHITECT PRIORTO ROUGH-IN.4. "F2" FIXTURE TO BE TOP MOUNTED TO BEAMS. COORDINATEMOUNTING OF FIXTURE WITH ARCHITECT PRIOR TO ROUGH-IN.5. "F3" FIXTURE TO BE TIGHTLY MOUNTED TO UNDERSIDE OFBEAMS. COORDINATE MOUNTING OF FIXTURE WITH ARCHITECTPRIOR TO ROUGH-IN.6. FANS TO BE MOUNTED TO UNDERSIDE OF BEAMS.COORDINATE MOUNTING OF FAN WITH ARCHITECT PRIOR TOROUGH-IN.GENERAL NOTES:EXISTING AREA TO REMAIN. NO NEW SCOPE OF WORK.EXISTING ELECTRICAL PANELBOARD TO REMAIN AT SECONDFLOOR.EXISTING SWITCHBOARD TO REMAIN AT FIRST FLOOR.COORDINATE POINT OF CONNECTION TO OVERHEAD UNITHEATERS WITH MECHANICAL CONTRACTOR.PROVIDE #10 POWER BRANCH CIRCUIT CONDUCTORS.APPROXIMATE LOCATION OF ELV DRIVERS. TO BE INSTALLED IN ACONCEALED, VENTILATED AND ACCESSIBLE LOCATION. PROVIDEEXTRA LEAD WIRE.CIRCUIT ROUTED THRU ASTRONOMICAL TIME CLOCK.APPROXIMATE LOCATION OF HEATER REMOTE CONTROL PANEL.COORDINATE LOCATION WITH ARCHITECT PRIOR TO ROUGH IN.APPROXIMATE LOCATION OF NEW LCP PANEL WITHASTRONOMICAL TIME CLOCK.REPLACE EXISTING WALL SCONCE LIGHT FIXTURE WITH NEW.RECONNECT TO EXISTING LIGHTING CIRCUIT.COORDINATE POINT OF CONNECTION OF CONCEALED CABINETLIGHT WITH MILLWORK VENDOR PRIOR TO ROUGH IN.COORDINATE POINT OF CONNECTION OF ELECTRIC FIRE ELEMENTWITH ARCHITECT AND VENDOR PRIOR TO ROUGH IN.KEY NOTES:123456789101112T:\2018\2018-0031 cliffhouse bar patio\acad files\E-2.1.dwg 5-08-2018 - 4:28pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-0031SCALE:NORTH1LIGHTING PLAN - MCGINNIS PATIO1/4" = 1'-0"SCALE: NONEKEYPLANNONESCALE:NORTH2LIGHTING PLAN - BAR PATIO1/4" = 1'-0"SCOPE OF WORKDETAIL 1SCOPE OF WORKDETAIL 2ELECTRICAL PANEL LOCATIONELECTRICAL PANEL LOCATION ALL ELECTRICAL DEVICE SHOWN ARE EXISTING TO REMAIN U.O.N.ALL ELECTRICAL FEEDER CONDUIT AND CONDUCTORS AREEXISTING TO REMAIN.ELECTRICAL PANELS ARE EXISTING TO REMAIN WITH MODIFIEDLOADS.NEW CONDUIT SHALL BE EMT WITH SET SCREW FITTINGS FORINTERIOR APPLICATIONS AND RAIN TIGHT COMPRESSION FITTINGSFOR EXTERIOR APPLICATIONS.NEW CONDUCTORS SHALL BE THWN-2/THHN-2 INSULATION,COPPER MATERIAL.1.GENERAL NOTES:EXISTING UTILITY METER.EXISTING GROUNDING ELECTRODE SYSTEM TO REMAIN.REVISED LOAD ON EXISTING PANEL.EXISTING LOAD ON EXISTING CIRCUIT BREAKER.REVISED LOAD ON EXISTING CIRCUIT BREAKER.PROVIDE NEW GFCI CIRCUIT BREAKER IN EXISTING SPACECIRCUIT POSITION. NEW CIRCUIT BREAKER TO MATCH EXISTINGMANUFACTURER AND AIC VALUES.KEY NOTES:2.3.MEXISTING SWITCHBOARD "MSB" - 1200A, 208/120V, 3Ø, 4W, 42,000 AICNGEXIST FEEDEREXISTINGPANEL"2LA" EXISTINGPANEL"2LC" 200AS200AF3P200AS200AF3P200AS200AF3P100AS60AF3PBUILDINGSTEEL1#3/0 CU TO UFER1#3/0 CU TO COLDWATER PIPE1#3/0 CU TOBUILDING STEELEXISTINGUTILITYPADMOUNTTRANSFORMERUTILITY EXISTING12KV CIRCUITEXISTINGUTILITY208Y/120V200AS200AF3P23EXIST FEEDEREXIST FEEDER4.5.EXISTINGPANEL"1LA" EXISTINGPANEL"2LB" 1200AS1200AF3P100AS40AF3P200AS150AF3P200AS150AF3P200AS150AF3P100AF20AT3P100AS100AF3P100AS100AF3P200AS200AF3P100AS20AF3PEXIST FEEDEREXIST FEEDEREXISTINGPANEL"CR" EXISTFEEDER100A3PEXISTFEEDER15EXISTING49FLAELEVATOREXISTFEEDER600A3PEXISTFEEDEREXISTINGAC-1EXISTFEEDER200A3PEXISTFEEDEREXISTINGAC-2EXISTFEEDER200A3PEXISTFEEDEREXISTINGAC-3EXISTFEEDER200A3PEXISTFEEDEREXISTINGAC-4EXISTFEEDER60A3PEXISTFEEDEREXISTINGAC-5EXISTFEEDER60A3PEXISTFEEDEREXISTINGAC-6EXISTFEEDER200A3PEXISTFEEDEREXISTINGFOUNTAINPUMPEXISTFEEDER30A3PEXISTFEEDEREXISTINGFOUNTAINPUMP454414561236564554543CKT#KVA LOADTRIP/POLESBREAKERCIRCUIT DESCRIPTIONROOMMOUNTINGFED FROMNOTEA B CCOND. FEEDER RACEWAY AND CONDUCTORSNEUTRALBUS AMPSVOLTSAICMAIN BKRLUGSMSBMAIN ELECTRICAL ROOMFLOOREXISTINGUTILITY100%1200208Y/120V 3P 4WSTANDARDMLO42,000100/35.881-1/4"C,3#2,#2N,#8G5.88 5.881200/311.12"C,3#3/0,#3/0N,#6G11.1 11.12200/320.52"C,3#3/0,#3/0N,#6G21.2 20.13200/312.32"C,3#3/0,#3/0N,#6G12.3 12.34200/311.42"C,3#3/0,#3/0N,#6G14 12.7560/33.161-1/4"C,3#4,#4N,#10G3.16 3.16640/33.173/4"C,3#8,#8N,#10G3.17 3.177150/310.91-1/2"C,3#1/0,#1/0N,#6G10.9 10.98150/310.91-1/2"C,3#1/0,#1/0N,#6G10.9 10.99150/310.91-1/2"C,3#1/0,#1/0N,#6G10.9 10.910100/36.731-1/4"C,3#2,#2N,#8G6.73 6.7311100/36.731-1/4"C,3#2,#2N,#8G6.73 6.7312200/311.12"C,3#3/0,#3/0N,#6G11.1 11.11320/31.21/2"C,3#12,#12N,#12G1.2 1.214CONN. KVA CALC. KVACONN. KVACALC. KVATOTAL CONNECTED KVA BY PHASEBALANCED THREE PHASE AMPSHEATINGCONTINUOUSNONCONTINUOUSKITCHEN EQUIPNONCOIN/DIVERSETOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTING(100%)(125%)(100%)126 129 127003820012229.217341.56.8948.417333.25.521,030(N/A)(N/A)003730012215HP ELEVATORPANEL 1LAPANEL 2LAPANEL 2LBPANEL 2LCPANEL CRAC-1AC-2AC-3AC-4AC-5AC-6FOUNTAIN PUMP-1FOUTAIN PUMP-2LUGSMAIN BKRAICCIRCUIT DESCRIPTIONLOADKVACKTBKRCKT#CKT#LOADBKRCKTCIRCUIT DESCRIPTIONKVAROOMMOUNTINGFED FROMNOTEVOLTSBUS AMPSNEUTRALPANEL:2ND FLFLUSH208Y/120V 3P 4W20010,000MLOSTANDARDEXISTINGMSB100%2LCa20/1 0.54620/1 112b20/1 0.54620/1 143c20/1 1.1720/1 165a20/1 1.1720/1 178b20/1 1.1720/1 1109c20/1 0.54620/1 11211a20/1 0.54620/1 0.751314b20/1 0.54620/1 0.4521615c20/1 1.2920/1 0.51817a20/1 0.93620/1 0.4521920b20/1 130/1 2.42221c20/1 120/1 12423a20/1 120/1 0.722526b20/1 120/1 0.92827c20/1 120/1 0.1923029a20/1 120/1 0.2793132b20/1 130/1 13433c20/1 120/1 13635a20/1 120/1 13738b20/1 120/1 14039c20/1 120/1 14241PHASE BALANCE PERCENT: PHASE APHASE BPHASE CBALANCED THREE PHASE AMPSCONN. KVA CALC. KVACONN. KVACALC. KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGTOTAL KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)75.989.7%110%99.9%27.438.121.5331.291.2932.40.5890.4710010000100(N/A)(N/A)EXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADPATIO HEATERPATIO HEATERPATIO FANPATIO LTGSEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADLUGSMAIN BKRAICCIRCUIT DESCRIPTIONLOADKVACKTBKRCKT#CKT#LOADBKRCKTCIRCUIT DESCRIPTIONKVAROOMMOUNTINGFED FROMNOTEVOLTSBUS AMPSNEUTRALPANEL:2ND FLFLUSH208Y/120V 3P 4W20022,000MLOSTANDARDEXISTINGMSB100%2LAa20/1 120/1 1.212b20/2 320/1 1.243c |20/1 1.265a20/2 320/1 0.7278b |20/1 0.72109c20/1 120/1 0.1921211a40/3 10.520/1 0.2521314b |20/1 11615c |20/1 11817a30/2 3.820/1 11920b |20/1 12221c20/1 120/1 12423a20/1 120/1 12526b20/1 120/1 12827c20/1 120/2 33029a30/3 6.6 |3132b |30/3 6.63433c | |3635a20/2 3 |3738b |20/1 14039c20/1 120/1 1.84241PHASE BALANCE PERCENT: PHASE APHASE BPHASE CBALANCED THREE PHASE AMPSCONN. KVA CALC. KVACONN. KVACALC. KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGTOTAL KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)16899.6%103%97.3%60.361.812.715.400006.315.040041.3000041.300(N/A)(N/A)EXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADPATIO HEATERPATIO HEATERINTERIOR/PATIO FANPATIO LTGSEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADEXISTING LOADCABINET LTGELECTRIC FIRE ELEMENTVOLTAGE DROP SCHEDULEDEVICEFEEDERVOLTAGE DROP WIRE SIZEBRANCH CIRCUITMAX VOLTAGE DROP WIRE SIZETOTAL VOLTAGEDROPMSB0%(3)#600kcmil --0%2LA 0.38%#3/01.15% (CKT 10)#121.52%2LC 0.63%#3/00.76% (CKT 28)#101.39%FAULT CURRENT SCHEDULEDEVICE FAULT AIC RATING L-N VOLTS UTILITYFAULTFED FROMDEVICE FAULTFEEDERSIZE LENGTHTOTALMOTORFAULTDIRECTLY CONNECTEDMOTOR LOADKVA FAULTMSB32,292 42,000 120V 30,000(3)#600kcmil2,292 2032,2512LA 20,528 22,000 120V 19,650 MSB30,000 #3/031'8782LC 9,532 10,000 120V 9,332 MSB30,000 #3/0113'2003.6941** EXISTING PANEL, UL SERIES RATED.T:\2018\2018-0031 cliffhouse bar patio\acad files\E-4.1.dwg 5-08-2018 - 4:28pm (crubio) CLIFFHOUSE / BAR PATIO REMODEL 78250 HIGHWAY 111 LA QUINTA, CA 922531044 PIONEER WAY, SUITE EEL CAJON, CA 92020TEL: 619.334.6020DEVELOP.DESIGN.DELIVERConsulting Engineers, Inc.R A N Y ANRTLAEERA NGINE19124E CExp. 06/30/18ETOFASR TEELR O FLACI LRTICA NI D STER GI E P ROFALEONSIESBEW.RBCE JOB #2018-00311SINGLE LINE DIAGRAMSCALE: NONE