Loading...
27984 La Quinta Village Shopping CenterF- z�� ON SITE HYDROLOGY REPORT for the LA QUINTA VILLAGE PROJECT SUBMITTED BY: THE KEITH COMPANIES COACHELLA VALLEY y THE KEITH COMPANIES APRIL 14, 1994 Introduction & Summary The proposed La Quinta Village (Ralphs Shopping Center) is located at the Northwest corner of Calle Tampico and Washington Street, across from the La Quinta Civic Center. The project site is comprised of approximately 9.2 acres of relatively flat terrain having less than one foot difference in relief. Design criteria established from the City of La Quinta ordinances require retention of the 100 year, 24 hour storm on site with an emergency escape overflow following existing drainage patterns. The storm drain facilities at the intersection of Washington and Tampico will be utilized only for draining the retention basin after the storm waters have subsided. The ponding water within the site requires mechanical forces to help in its subsidences due to the percolation at this site is relatively nil. Ponding water will inundate a portion of the parking area to a maximum depth of 811. Circulation patterns will be altered with this scenario, but the building structures will be protected and alternate access will still be available completely around the parking areas. The storm drain facilities will have a dry well system to accommodate the low flow nuisance water and the storm pipe handling the 14 year storm. Excess water will pond over land into the retention basin through a landscaped scale. Retention basin capacity will be graded with maximum 3:1 side slopes and 6 foot depth containing 1.15 Acwft and the parking area containing the remainder 0.4 Ac-ft. All calculations assume type C soil and 0" percolation within a commercial development, due to the constraints of the site, to existing conditions, and experience at this location. Hydrology/Hydraulic Review The hydrology was reviewed using the Riverside County Synthetic Unit Hydrograph method for the 100 year/24 hour event to determine the volume of storm water to retain. Peak run of rates were derived for the storm drain design using the Rational Table method. (Riverside County Flood Control and Water Conservation District 1978 manual). Attached charts, computer prints, exhibits and maps identify the parameters and variables used to estimate the peak run-off and total run-off to be retained within the project site. Retention Basin Volumes: Corner Landscape Area: 1.15 Ac-ft (3:1 max slopes 6'deep) Parking Lot Area: 0.40 Ac-ft (34,800 SF x Ave 0.5 deep) Storm Drain Pipe: Q= (. 463/n) D%S""-' Q=(.463/.013) (2)86(.01)"A` _ (35.62) (6.35) (.1) = 22.6 <22.8 OK n=0.013 D=24" S=0.010 riverside County Rational Hydrology Program Civi1CADD/Civi1DESIGN Engineering Software, (c) 1990 Version 2.7 Rational Hydrology Study Date: 04 14 94 --------------------..____- __ ____ LA QUINTA VILLAGE SHOPPING CENTER _ JN 40090.00 BY: MR CHECKED KRS Q10 ********* _ -- Hydrology Study Control Information ********** - -- ------------------ -- - -- - - -- Rational Method Hydrology Program based on -- - -� r Riverside County Flood Control & Water Conservation District 1978 hydrology manual Storm event (year) = 10.00 Antecedent Moisture Condition = 2 Standard intensity -duration curves data (Plate D-4.1) For the [ Cathedral City ] area used. 10 year storm 10 minute intensity = 2.770 (in./hr.) 10 year storm 60 minute intensity = 0.980 (in./hr.) 100 year storm 10 minute intensity = 4.520 (in./hr.) 100 year storm 60 minute intensity = 1.600 (in./hr.) Storm event year = 10.0 Calculated rainfall intensity data: 1 hour intensity = 0.980 (in./hr.) Slope of intensity duration curve = 0.5800 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 100.000 to Point/Station 300.000 **** INITIAL AREA EVALUATION **** Initial area flow distance = 700.000(Ft.) Top (of initial area) elevation = 41.500(Ft.) Bottom (of initial area) elevation = 37.200(Ft.) Difference in elevation = 4.300(Ft.) Slope = 0.00614 s(percent)= 0.61 TC = k(0.300)*[(lengthA3)/(elevation change)]^0.2 Initial area time of concentration = 11.415 min. Rainfall intensity = 2.566(In/Hr) for a 10.0 COMMERCIAL subarea type Runoff Coefficient = 0.883 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 1.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 69.00 Initial subarea runoff = 10.897(CFS) Total initial stream area = 4.810(Ac.) Pervious area fraction = 0.100 year storm +++++t+++++++++++t++++++++++..++f+++....++.++..+++++++++++++++++++++++ Process from Point/Station 200.000 to Point/Station 300.000 **** SUBAREA FLOW ADDITION **** COMMERCIAL subarea type Runoff Coefficient = 0.883 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 1.000 Decimal fraction soil group D = 0.000 RI index for soil(AMC 2) = 69.00 Time of concentration = 11.42 min. Rainfall intensity = 2'.566(In/Hr) for Subarea runoff = 8.042(CFS) for Total runoff = 18.939(CFS) Total area End of computations, total study area = The following figures may be used for a unit hydrograph a 10.0 year storm 3.550(Ac.) 8.360(Ac.) 8.36 (Ac.) study of the same area. Area averaged pervious area fraction(Ap) = 0.100 Area averaged RI index number = 69.0 Km_9q_R � f k 0 zu,«oo� ¥°u33 Uo/>> U-0Lu G A U,U- �U-U.�■ /]2Q2 }( ]§ t)§0 �oonco w w 2 CO §§§� d000fa =o� P: zda- z®Jk &�> w�ww § �(2i� ) ����§bo 2222�a 0 UJ 22 §a. _j 2 k�a; -§ Inz & § 3 }§@@ ° § � � 5 % �z yo z_ nmj k)}w�- agwuruo -o3§�r U- CO §}�k2}§U)o9Q§� §<�? ��\ uj i<;Fcw �w /��/�52 0�-m 0 z mo0« S D n�-> GIVEN: Solution: From Chart: (a) Discharge (b) Curb Type C.B. # I CURB OPENING (SUMP) Q: _ �-7-A-2-) "D" I q cfs 4" Rolled 6" Rolled H (depth at opening) = inches h (height of opening) = % inches H/h= �? / 7 _ Q/ft. opening = L cfs L required USE L= lv Cl, ft. ` - 1073. 03 Z., 5 •:.. I I 10 �a .9 8 4 10 6 3 r 9 4 2 - .7 0 0 3 == 7 -• 6.5 1.0 Z. 5.5 - F- 0 O W W 5 x �� -- {� • 7� uW. 4 z Z .3- s a 1.4 a 3.5 _ _ Z LL. o 9• � 0 _ •I d 0 f ►- .2 5 3 F. .08 � 1 x 0 = 0 06 .3 c�Ix W. x W - 2.5 0 .04 3 5 . 2 cc .03 .2 C w _ a x ? ?. .02 a •2 _ �- W 2 c .1 5 0 .01 0 .15 N T. a 1.5 k e URS L0C�L EPR story t 0.1 BUREAU OF PUBLIC ROADS DIVISION TWO WASH., D. C. NOMOGRAPH FOR CAPACITY OF CURB OPENING INLETS AT LOW POINTS �- �- LEGEND A SUB, 4.81 ARE 100 NODE ELEV 9CAE.E: 10•1W I-- co A= oars+ ■Auer +� CITY OF LA OUINTA LA QW11 A \410 S ROPPING MM RYDROLCGY MAP mmm MP" IL Y1 cmm K&- sr -