MUP 2019-0004 78998 Miles Ave Telecom Facility (03.20.2019)March 20, 2019 Paulina Mendoza 959 South Coast Drive, Suite 200 Costa Mesa, CA 92626 SUBJECT: MINOR USE PERMIT 2019-0004: 78998 MILES AVENUE MODIFICATIONS TO EXISTING TELECOMMUNICATION FACILITY Dear Ms. Mendoza: The Design and Development Department has approved your request to install three (3) new panel antennas and RRUs,and associated equipment in an existing shelter at a telecommunication facility located at 78998 Miles Avenue. Approval of this application is subject to the attached exhibits for the Minor Use Permit and the following Findings and Conditions of Approval: FINDINGS 1.Consistency with the General Plan: The proposed equipment at the existing telecommunication facility are consistent with the goals, objectives and policies of the General Plan, in that the proposed equipment is intended to enhance community access to quality wireless communication services. 2.Public Welfare: Approval of the new equipment for an existing telecommunication facility will not create conditions materially detrimental to the public health, safety and general welfare. 3.The proposed new equipment at the existing telecommunication facility will not create new adverse visual impacts. No change to the height of the antenna location or general configuration is proposed. The associated equipment will be placed entirely within existing equipment cabinet. 4.The proposed new antennas and equipment is designed to facilitate continued function of the existing antenna array, without modifying the height or other pre- existing conditions to maintain the service provider’s objectives for coverage within this portion of the community. 5.The proposed new and replacement equipment is necessary to improve community access to wireless services. CONDITIONS 1. The applicant/property owner agrees to defend, indemnify, and hold harmless the City of La Quinta (the “City”), its agents, officers and employees from any claim, or litigation arising out of the City’s approval of this project. This indemnification shall include any award toward attorney’s fees. The City of La Quinta shall have the right to select its defense counsel in its sole discretion. The City of La Quinta shall promptly notify the applicant of any claim, action, or proceeding and shall cooperate fully in the defense. 2. The applicant shall comply with all provisions of La Quinta Municipal Code Section 9.170 “Wireless Telecommunication Facilities”. 3. The applicant shall comply with any applicable provisions contained in Conditions of Approval for Conditional Use Permit 2009-124 and MUP 2012-1046. 4. The applicant is permitted to install and remove the equipment identified on the scope of work on the approved and attached plans for MUP2019-0004. All new and replacement equipment shall be painted to match the color on the array. Applicant is also permitted to install all other related equipment within existing equipment cabinets located in the lease area. 5. The applicant shall obtain all necessary building permits from the City’s Building Division, and is responsible for meeting all applicable plan check submittal requirements. Plans submitted for building permit plan check shall include an accurate vicinity map. This decision may be appealed to the Planning Commission by any party who submits the necessary paperwork and filing fee of $1,505.00 to this office within 15 days of the date of approval of this permit. Should you have any questions please contact me at (760) 777- 7069. Sincerely, Carlos Flores Interim Senior Planner TITLE SHEET REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR T-1 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 VICINITY MAP LOCAL MAP IF USING 11" X 17" PLOT, DRAWINGS WILL BE HALF SCALE DRAWING INDEX DRAWING SCALE T-1 SHEET NO. TITLE SHEET SHEET TITLE 0 REV T-2 GENERAL NOTES 0 A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN, NEW / EXISTING EQUIPMENT PLAN A-3 NEW / EXISTING ANTENNA PLAN, AND ANTENNA SCHEDULE A-4 NEW / EXISTING WEST ELEVATION A-5 NEW / EXISTING NORTH ELEVATION A-6 EQUIPMENT DETAILS G-1 GROUNDING DETAILS R TOLL FREE: 1-800-227-2600 ORwww.digalert.org DRAWING APPROVALS PROJECT DESCRIPTION PROJECT TEAM SITE INFORMATION THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR MODIFICATIONS. PROJECT MANAGER: _________________________________ DATE: __________ RF ENGINEER: _______________________________________ DATE: __________ SITE ACQUISITION MANAGER: _________________________ DATE: __________ CONSTRUCTION MANAGER: ___________________________ DATE: __________ A&E MANAGER: ______________________________________ DATE: __________ x 2016 CALIFORNIA ADMINISTRATIVE CODE x 2016 CALIFORNIA BUILDING CODES, VOL. 1 & 2 x 2016 CALIFORNIA RESIDENTIAL CODE x 2016 CALIFORNIA ELECTRICAL CODES x 2016 CALIFORNIA MECHANICAL CODES x 2016 CALIFORNIA PLUMBING CODES x 2016 CALIFORNIA FIRE CODES x 2016 CALIFORNIA ENERGY CODES x 2016 CALIFORNIA EXISTING BUILDING CODE x 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE x 2016 CALIFORNIA REFERENCED STANDARDS CODE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATE CODE PART 2, TITLE 24 CHAPTER 11B, SECTION 1103B ENGINEERING CODE COMPLIANCE SITE LOCATION SITE LOCATION PROPERTY OWNER: ADDRESS: CONTACT: PHONE: APPLICANT: ADDRESS: LATITUDE (NAD83): LONGITUDE (NAD 83): GROUND ELEVATION: APN#: COUNTY: ZONING JURISDICTION: ZONING DISTRICT: POWER COMPANY: TELCO COMPANY: FAMILY HERITAGE CHURCH OF THE VALLEY , INC 78998 MILES AVE. LA QUINTA, CA 92253 TBD (760) 345-0355 T-MOBILE 2008 MCGAW AVE IRVINE, CALIFORNIA 92614 33.723777800 -116.2868610000 ±92'-0" 604-032-026 RIVERSIDE COUNTY CITY OF LA QUINTA MEDIUM HIGH DENSITY RESIDENTIAL(RMH) IMPERIAL IRRIGATION DISTRICT TWC 0 0 0 0 0 0 0 A&E PROJECT MANAGER: XD INDUSTRIES 1572 N. BATAVIA ST. SUITE 1D ORANGE, CA 92867 CONTACT: JOSUE ROMERO PHONE: (714) 783-5990 EMAIL: jromero@xd-ind.com ENGINEER: XD INDUSTRIES 1572 N. BATAVIA ST. SUITE 1D ORANGE, CA 92867 CONTACT: CHRIS LEE PHONE: (949) 468-9702 EMAIL: clee@xd-ind.com RF ENGINEER: 2008 MCGAW AVE. IRVINE, CA 92614 CONTACT: ALBERT LANDICHO PHONE: (707) 342-8123 EMAIL: albert.landicho2@t-mobile.com CONSTRUCTION MANAGER: ERICSSON INCORPORATED 6160 STONERIDGE MALL RD., #400 PLEASANTON, CA 94588 PROJECT NUMBER: IE25790A SBA SITE NUMBER: CA40771-T-01 PROJECT NAME: IE790 FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 ® R PROJECT: L700 4X2 TMO PROJECT MANAGER: 2008 MCGAW AVENUE, IRVINE, CA 92614 CONTACT: DUAN DAO PHONE: (949) 567-6815 EMAIL: duan.dao@t-mobile.com PROPERTY SPECIALIST SBA: 510 GOETZ AVENUE SANTA ANA, CA 92707 CONTACT: PAULINA MENDOZA PHONE: (949) 398-8050 X1810 EMAIL: pmendoza@sbasite.com T-MOBILE PROPOSES TO MODIFY/ INSTALL AN EXISTING/NEW WIRELESS INSTALLATION. THE SCOPE WILL CONSIST OF THE FOLLOWING: AT ANTENNA LEVEL: x INSTALL (3) NEW PANEL ANTENNAS, (1) PER SECTOR x INSTALL (3) NEW 4449 RRUS, (1) PER SECTOR AT EQUIPMENT LEVEL: x INSTALL (1) NEW 6 X12 HCS 40M 6 AWG HYBRID CABLE x UTILIZE (1) EXISTING BB 5216 x INSTALL (1) NEW XMU x INSTALL (1) NEW BB6630 FOR N600 (DARK) RFDS:IE25790A_L700_CMP4- 4X2_4.1 12.07.18 EXP: 12/31/2020 PLANNING APPROVAL ADMINISTRATIVE CASE# ____________________ EXHIBIT# ____________________ INITIAL cflores DATE 03/20/2019 5:10:17 PM MUP2019-0004 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR T-2 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 GENERAL NOTES #3 AND #4..............2'-0" #8............................5'-3" #5...................................2'-6" #9............................6'-8" #6.................................3'-0" #10...........................8'-6" #7.....................................4'-1" #11.............................10'-5" GENERAL 1. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. 2. THE CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER OF ANY ERRORS, OMISSIONS, OR DISCREPANCIES AS THEY MAY BE DISCOVERED IN THE PLANS, SPECIFICATIONS, & NOTES PRIOR TO STARTING CONSTRUCTION. INCLUDING BUT NOT LIMITED BY DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERRORS, OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE METHOD OF CORRECTION SHALL BE APPROVED BY THE ARCHITECT/ENGINEER. 3. PRIOR TO STARTING CONSTRUCTION THE CONTRACTOR HAS THE RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON THE PLANS, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR OR SUBCONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGE TO THE UTILITIES CAUSED DURING THE EXECUTION OF THE WORK. 4. A COPY OF THE APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL CONSTRUCTION SETS REFLECT THE SAME INFORMATION AS THE APPROVED PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS AT THE SITE FOR THE PURPOSE OF DOCUMENTING ALL AS-BUILT CHANGES, REVISIONS, ADDENDUM'S, OR CHANGE ORDERS. THE CONTRACTOR SHALL FORWARD THE AS-BUILT DRAWINGS TO THE ARCHITECT/ENGINEER AT THE CONCLUSION OF THE PROJECT. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE FROM START OF PROJECT TO COMPLETION OF PROJECT. 6. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE TEMPORARY POWER, WATER, AND TOILET FACILITIES. 7. ALL CONSTRUCTION THROUGH THE PROJECT SHALL CONFORM TO THE 2016 CBC AND ALL OTHER GOVERNING CODES. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE ON NOR PROVIDE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. 9. THE CONTRACTOR SHALL SUPERVISE AND COORDINATE ALL WORK, USING HIS PROFESSIONAL KNOWLEDGE AND SKILLS. HE IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCING AND COORDINATING ALL PORTIONS OF THE WORK. 10. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTIONS WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN THE PERMIT AND MAKE FINAL PAYMENT OF SAID DOCUMENT. 11. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE UNLESS OTHERWISE NOTED. 12. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR SUPPORTS FOR INSTALLATION OF ITEMS INDICATED ON THE DRAWINGS. 13. THE CONTRACTOR SHALL PROVIDE THE FIRE MARSHALL APPROVED MATERIALS TO FILL/SEAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. 14. NEW CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL BE MATCHED IN FORM, TEXTURE, MATERIAL AND PAINT COLOR EXCEPT AS NOTED IN THE PLANS. 15. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AVAILABLE AS REQUIRED BY THE LOCAL GOVERNING AGENCY RESPONSIBLE FOR RECORDING THE RESULTS. 16. ALL GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHERWISE. 17. ALL DEBRIS AND REFUGE IS TO BE REMOVED FROM THE PROJECT DAILY. PREMISES SHALL BE LEFT IN A CLEAN BROOM FINISHED CONDITION AT ALL TIMES. 18. ALL SYMBOLS AND ABBREVIATIONS ARE CONSIDERED CONSTRUCTION INDUSTRY STANDARDS. IF A CONTRACTOR HAS A QUESTION REGARDING THEIR EXACT MEANING THE ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATIONS. 19. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 20. CONTRACTORS SHALL VISIT THE SITE PRIOR TO BID TO ASCERTAIN CONDITIONS WHICH MAY ADVERSELY AFFECT THE WORK OR COST THEREOF. 21. THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSION, ELEVATION, ETC. NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTION OF THE WORK TO THE EXISTING WORK. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY FOR FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. AND DISCREPANCY SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT/ ENGINEER. 22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. 23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF THE ENGINEER. 24. NO CHANGES ARE TO BE MADE TO THESE PLANS WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT/ ENGINEER. UNAUTHORIZED CHANGES RENDER THESE DRAWINGS VOID. 25. ANY REFERENCE TO THE WORDS APPROVED, OR APPROVAL IN THESE DOCUMENTS SHALL BE HERE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUB-CONTRACTORS OF ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR SPECIFIED. 26. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 10. GENERAL CONTRACTOR SHALL NOTIFY THE ENGINEER AND ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS, PRIOR TO STARTING WORK. SITE PREPARATION NOTES: 1. THE PREPARATION OF THE SITE FOR CONSTRUCTION SHALL INCLUDE THE REMOVAL OF ALL BROKEN CONCRETE, TREE TRUNKS AND ANY OTHER DEBRIS THAT WOULD BE DAMAGING TO THE FOOTINGS OF THE NEW STRUCTURE. 2. BACK FILLING AT TRENCHES SHALL BE OF CLEAN, STERILE SOIL HAVING A SAND EQUIVALENT OF 30 OR GREATER. BACK FILLING SHALL BE DONE IN 8 INCH LAYERS, MOISTURE CONDITIONED AND PROPERLY COMPACTED. ADEQUATE DRAINAGE SHALL BE PROVIDED SUCH THAT NO PONDING OCCURS. 3. ALL FOUNDATION FOOTINGS SHALL EXTEND INTO AND BEAR AGAINST NATURAL UNDISTURBED SOIL OR APPROVED COMPACTED FILL. FOOTINGS SHALL EXTEND INTO SOIL DEPTH AS INDICATED IN PLANS. 4. SHOULD ANY LOOSE FILL, EXPANSIVE SOIL, GROUND WATER OR ANY OTHER UNEXPECTED CONDITIONS BE ENCOUNTERED DURING THE EXCAVATION FOR THE NEW FOUNDATION, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED AND ALL FOUNDATION WORK SHALL CEASE IMMEDIATELY. 5. WITHIN AN AREA A MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS, EXCAVATE A MINIMUM OF 4" OF EXISTING SOIL. REMOVE ALL ORGANICS, PAVEMENT, ROOTS, DEBRIS AND OTHERWISE UNSUITABLE MATERIAL. 6. THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED BY PROBING OR TESTING TO CHECK FOR POCKETS OF SOFT OR UNSUITABLE MATERIAL. EXCAVATE UNSUITABLE SOIL AS DIRECTED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY. 7. PROOFROLL THE SURFACE OF THE EXPOSED SUBGRADE WITH A LOADED TANDEM AXLE DUMP TRUCK. REMOVE ALL SOILS WHICH PUMP OR DO NOT COMPACT PROPERLY AS DIRECTED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY. 8. FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE IN 8" LOOSE LIFTS AND THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D-698. COMPACT TO A MINIMUM OF 90% RELATIVE COMPACTION 9. THE STRUCTURAL DRAWINGS HERE IN REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 10. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW OR EXISTING SURFACES, STRUCTURES OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF THE PROPERTY OWNER. THE CONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGED AREAS. 11. WHEN REQUIRED STORAGE OF MATERIALS OCCURS, THEY SHALL BE EVENLY DISTRIBUTED OVER THE FLOOR OR ROOF SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE. TEMPORARY SHORING OR BRACING SHALL BE PROVIDED WHERE THE STRUCTURE OR SOIL HAS NOT ATTAINED THE DESIGN STRENGTH FOR THE CONDITIONS PRESENT. 12. BEFORE PROCEEDING WITH ANY WORK WITHIN THE EXISTING FACILITY, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING STRUCTURAL AND OTHER CONDITIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY BRACING, SHORING AND OTHER SAFEGUARDS TO MAINTAIN ALL PARTS OF THE EXISTING WORK IN A SAFE CONDITION DURING THE PROCESS OF DEMOLITION AND CONSTRUCTION AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE EXISTING WORK WHICH ARE TO REMAIN. SUBMITTALS: SUBMITTALS: SUBMITTALS FOR SHOP DRAWINGS, MILL TESTS, PRODUCT DATA, ECT. FOR ITEMS DESIGNED BY THE ARCHITECT/ ENGINEER OF RECORD SHALL BE MADE TO THE ARCHITECT/ENGINEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL REVIEW THE SUBMITTAL BEFORE FORWARDING TO THE ARCHITECT. SUBMITTALS SHALL BE MADE IN ADVANCED TO ARCHITECT-ENGINEER. SUBMITTALS REQUIRED FOR EACH SECTION OF THESE NOTES ARE SPECIFIED IN THAT SECTION. SHOP DRAWING REVIEW: REVIEW BY THE ARCHITECT/ENGINEER IS FOR GENERAL COMPLIANCE WITH THE DESIGN CONCEPT AND THE CONTRACT DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS, NOR DEPARTURES THRERFROM. THE CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTION FABRICATION PROCESSES. ACCESSIBILITY NOTE: THE TELECOMMUNICATIONS EQUIPMENT SPACE SHOWN HEREON THESE PLANS IS NOT CUSTOMARILY OCCUPIED. WORK TO BE PERFORMED IN THIS FACILITY CANNOT REASONABLY BE PERFORMED BY PERSONS WITH A SEVERE IMPAIRMENT: MOBILITY, SIGHT, AND/OR HEARING. THEREFORE, PER 2016 CALIFORNIA BUILDING CODE SECTION 1103B.1 EXCEPTION 1, THIS FACILITY SHALL BE EXEMPTED FROM ALL TITLE 24 ACCESS REQUIREMENTS. BID WALK NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONSTRUCTION CONDITIONS BEFORE SUBMITTAL OF FINAL BIDS, START OF CONSTRUCTION AND/OR FABRICATION. AFTER THOROUGHLY EXAMINING THE PLANS AND EXISTING SITE CONDITIONS NOTIFY THE ENGINEER IN WRITING OF ANY OMISIONS/DISCREPANCIES, OR ANY ITEMS NEEDING CLARIFICATION PRIOR TO SUBMITTING FINAL BIDS. 2. IF THE ENGINEER IS NOT NOTIFIED OF ANY OMISIONS/DISCREPANCIES OR CLARIFICATIONS IN WRITING AS DESCRIBED IN #1 IT WILL BE CONFIRMED THAT THE CONTRACTOR HAS CONSIDERED ALL ITEMS THAT WILL AFFECT THE COST OF THE CONSTRUCTION OF THE SITE UNDER THE MOST STRINGENT CONDITIONS. THE CONTRACTOR WILL NOT BE ENTITLED TO ANY ADDITIONAL COMPENSATION AFTER FINAL BIDS HAVE BEEN SUBMITTED AND AWARDED FROM CARRIER. STRUCTURAL STEEL: 1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE LATEST REVISED EDITION OF THE AISC MANUAL OF STEEL CONSTRUCTION, WHICH INCLUDES THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, THE CODE OF STANDARD PRACTICE AND THE AWS STRUCTURAL WELDING CODE. IDENTIFY AND MARK STEEL PER CBC 2203. 2. STRUCTURAL STEEL SHOP DRAWINGS SHALL BE REVIEWED BY THE ENGINEER/ARCHITECT PRIOR TO FABRICATION. 3. GROUTING OF COLUMN BASE PLATES: BASE PLATES SHALL BE DRYPACKED OR GROUTED WITH NON-SHRINK, NON-FERROUS GROUT. MINIMUM COMPRESSIVE STRENGTH SHALL BE 4,000 PSI AT 28 DAYS. ALL SURFACES SHALL BE PROPERLY CLEANED OF FOREIGN MATERIAL PRIOR TO GROUTING. 4. ALL EXPOSED WELDS SHALL BE FILLED AND GROUND SMOOTH WHERE METAL COULD COME IN CONTACT WITH THE PUBLIC. 5. NO HOLES OTHER THAN THOSE SPECIFICALLY DETAILED SHALL BE ALLOWED THRU STRUCTURAL STEEL MEMBERS. BOLT HOLES SHALL CONFORM TO AISC SPECIFICATION, AND SHALL BE STANDARD HOLES UNLESS OTHERWISE NOTED. NO CUTTING OR BURNING OF STRUCTURAL STEEL WILL BE PERMITTED WITHOUT PRIOR CONSENT OF THIS ENGINEER. 6. WELDING: CONFORM TO AWS D1 1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH WABO REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. 7. BOLTING: ASTM A307 BOLTS SHALL BE INSTALLED "SNUG TIGHT" PER AISC. SECTION RCSC 8(C) ASTM A325 BOLTS SHALL CONFORM TO THE RCSC SPECIFICATION SECTION 8 (D). 8. FABRICATION: CONFORM TO AISC SPECIFICATION SEC M2 "FABRICATION" AND AISC CODE SEC 6 "FABRICATION AND DELIVERY" PERFORM WORK ON PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL. 9. GALVANIZING: ALL EXPOSED STEEL OUTSIDE THE BUILDING ENVELOPE SHALL BE HOT-DIPPED GALVANIZED. APPLY FIELD TOUCH-UPS PER SPECIFICATIONS. PER ASTM A153. STRUCTURAL STEEL NOTES: 1. HOLES IN STEEL SHALL BE DRILLED OR PUNCHED. ALL SLOTTED HOLES SHALL BE PROVIDED WITH SMOOTH EDGES. BURNING OF HOLES AND TORCH CUTTING AT THE SITE IS NOT PERMITTED. 2. ALL FRAMING CONNECTORS SUCH AS CONCRETE ANCHORS, HOLD-DOWNS, POST BASES, FRAMING CAPS, HANGER AND OTHER MISCELLANEOUS STRUCTURAL METALS SHALL BE AS MANUFACTURED BY SIMPSON STRONG TIE CO. OR APPROVED EQUAL. CONCRETE REINFORCEMENT: 1. REINFORCING STEEL SHALL BE SPLICED AS SHOWN OR NOTED BELOW. SPLICES AT OTHER LOCATIONS SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER. ALL VERTICAL WALL REINFORCEMENT SHALL BE CONTINUOUS BETWEEN SPLICE LOCATIONS SHOWN IN THE DETAILS. 2. ALL REINFORCING STEEL SHALL BE NEW DEFORMED BARS CONFORMING TO ASTM A-615 GRADE 60. LAP REINFORCING STEEL AT SPLICES TO THE FOLLOWING MINIMUM LENGTHS UNLESS NOTED OTHERWISE: 3. BARS SHALL BE CLEAN OF MUD, OIL, OR OTHER COATINGS LIKELY TO IMPAIR BONDING. 4. ALL REINFORCING SHALL BE SECURED IN PLACE PRIOR TO INSPECTIONS, PLACING CONCRETE, OR GROUTING MASONRY. 5. WELDING: BARS SHALL NOT BE WELDED UNLESS AUTHORIZED. WHEN AUTHORIZED. CONFORM TO ACI 301. SEC 3.2. 2.2. "WELDING" AND PROVIDE ASTM A706, GRADE 60 REINFORCEMENT. 6. FIELD BENDING: CONFORM TO ACI 301 SEC 3.3.2.8 "FIELD BENDING OR STRAIGHTENING". BAR SIZES #3 THROUGH #5 MAY BE FIELD BENT COLD THE FIRST TIME. OTHER BARS REQUIRE PREHEATING. DO NOT TWIST BARS 7. ALL REINFORCING MARKED CONTINUOUS (CONT.) ON THE PLANS AND DETAILS SHALL BE LAPPED 36xBAR DIAMETERS AT SPLICES UNLESS OTHERWISE NOTED. 8. SPLICE ALL BARS IN MASONRY WITH A MINIMUM OF 48 BAR DIAMETER LAPS (2'-0" MINIMUM). STRUCTURAL STEEL: MATERIALS: CONFORM TO ANCHOR BOLTS (HEADED): ASTM A307 ANCHOR BOLTS (J-TYPE): ASTM A36 BARS & PLATES: ASTM A36 BOLTS: ASTM A307 C-, M-, AND ANGLE SHAPES: ASTM A36 DEFORMED WELDED WIRE FABRIC: ASTM A497 EPOXY & EXPANSION ANCHORS: HILTI OR EQUIVALENT GROUT: EMBECO OR EQUIVALENT HIGH-STRENGTH BOLTS: ASTM A325SC OR (A325N) OTHER STRUCTURAL SHAPES: ASTM A36 REINFORCING BARS: ASTM A615. GRADE 60, DEFORMED BARS SMOOTH WELDED WIRE FABRIC: ASTM A185 STRUCTURAL WF SHAPES: ASTM A572-GR50 STEEL PIPE: ASTM A53, GRADE B TIE WIRE: 16.5 GAGE OR HEAVIER, BLACK ANNEALED TUBE STEEL & PIPE COLUMNS: ASTM A500, GRADE B WELDING ELECTRODES: E70XX W - SHAPES: ASTM A992, GRADE 50 EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR A-1 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 OVERALL SITE PLAN OVERALL SITE PLAN 0"40' 40'20' 24"x36" SCALE: 1" = 40'-0" 11"x17" SCALE: 1" = 80'-0"1 NEW T-MOBILE EQUIPMENT CABINETS AND ANTENNA LOCATION EXISTING PROPERTY LINE EXISTING 12'-0' WIDE ACCESS EASEMENT LADERA DR. EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING RESIDENTIAL HOUSE EXISTING PARKING LOT EXISTING PARKING LOTEXISTING PROPERTY LINEEXISTING PROPERTY LINEEXISTING PROPERTY LINE 149'-0" SETBACK 99'-9"SETBACK125'-4" SETBACK 649'-1"SETBACKTORTOLA CIR.ARBOLA CIR. OCOTILLO DR. APN: 604-032-026 APN: 604-032-026 APN: 604-032-022 ADAMS ST.EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR A-2 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 ENLARGED SITE PLAN, NEW / EXISTING EQUIPMENT PLAN NEW EQUIPMENT PLAN EXISTING EQUIPMENT PLAN 2' 1' 0"2' 24"x36" SCALE: 1/2" = 1'-0" 11"x17" SCALE: 1/4" = 1'-0"2 ENLARGED SITE PLAN 4'3' 2'1' 0" 4' 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"12' 1' 0"2' 24"x36" SCALE: 1/2" = 1'-0" 11"x17" SCALE: 1/4" = 1'-0"3 EXISTING 12'-0' WIDE ACCESS EASEMENT EXISTING 51'-0" HIGH MONOPALM W/ NEW T-MOBILE ANTENNAS LOCATION 25'-6"EXISTING T-MOBILE LEASE AREA18'-4" EXISTING T-MOBILE LEASE AREA EXISTING PARKING LOT EXISTING PARKING LOT APN: 604-032-026 APN: 604-032-026 NON-EXCLUSIVE TECH PARKING 18'-4" EXISTING T-MOBILE LEASE AREA 25'-6"EXISTING T-MOBILE LEASE AREAEXISTING T-MOBILE RBS 6131 W/ (1) BB5216, (1) DUG 20 & (1) DUW 30 EXISTING T- MOBILE 8'-0" HIGH CMU WALL ENCLOSURE EXISTING T- MOBILE STUB UPS8'-0"EXISTING T- MOBILE GPS ANTENNA EXISTING T- MOBILE CABLE TRAY EXISTING CURB W/ ROCK PLANTER EXISTING T- MOBILE METER EXISTING T- MOBILE KNOX BOX EXISTING SERVICE LIGHTS (TYP. OF 3) EXISTING T- MOBILE TELCO CABINET ON H-FRAME 18'-4" EXISTING T-MOBILE LEASE AREA 25'-6"EXISTING T-MOBILE LEASE AREAEXISTING T-MOBILE RBS 6131 W/ (1) BB5216, (1) DUG 20,(1) DUW 30 & (1) NEW XMU & (1) NEW BB6630 EXISTING T- MOBILE 8'-0" HIGH CMU WALL ENCLOSURE EXISTING T- MOBILE STUB UPS8'-0"EXISTING CURB W/ ROCK PLANTER EXISTING T- MOBILE TELCO CABINET ON H-FRAME EXISTING T- MOBILE STUB UPS EXISTING T- MOBILE METER EXISTING T-MOBILE GPS ANTENNA 1,2 A-4 1,2 A-5 EXISTING TREE, TYP. EXISTING CURB, TYP. NOTES: GC TO FIELD VERIFY EXACT EQUIPMENT LOCATION NOTES: GC TO FIELD VERIFY EXACT EQUIPMENT LOCATION EXISTING T-MOBILE 8'-0" WIDE SITE ACCESS GATE EXISTING PPC CABINET ON UNISTRUT EXISTING FIBER CABINET ON UNISTRUT EXISTING T- MOBILE CABLE TRAY EXISTING T- MOBILE METER EXISTING T-MOBILE 8'-0" WIDE SITE ACCESS GATE EXISTING PPC CABINET ON UNISTRUT EXISTING FIBER CABINET ON UNISTRUT EXISTING T-MOBILE RBS 6131 W/ (1) BB5216, (1) DUG 20,(1) DUW 30 & (1) NEW XMU & (1) NEW BB6630 EXISTING T- MOBILE CABLE TRAY EXISTING FIBER CABINET ON UNISTRUT EXISTING T- MOBILE GPS ANTENNA EXISTING T- MOBILE KNOX BOX EXISTING SERVICE LIGHTS (TYP. OF 3) EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR A-3 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 NEW / EXISTING ANTENNA PLAN, AND ANTENNA SCHEDULE 4 EXISTING EQUIPMENT SCHEDULE NEW EQUIPMENT SCHEDULE 2'0" 2' 24"x36" SCALE: 3/8" = 1'-0" 11"x17" SCALE: 3/16" = 1'-0"1'1EXISTING ANTENNA PLAN NEW ANTENNA PLAN 2'0" 2' 24"x36" SCALE: 3/8" = 1'-0" 11"x17" SCALE: 3/16" = 1'-0"1'2 3 A1 B1 C1 A2 B4 C4 SECTOR ANTENNA FREQUENCY MODEL SIZE (H x W x D) ANTENNA AZIMUTH RAD CENTER RRU / TMA CABLE LENGTH & TYPE A1 A2 A3 A4 -- ---- B1 B2 B3 B4 C1 C2 C3 C4 -- ---- -- ---- ERICSSON AIR21 KRC118023-1 B2A-B4P 30° 50'-0"56" x 12" x 8" ERICSSON AIR32 KRD901146-1 B66A-B2A 56.6" x 12.9" x 8.7" U1900/G1900 L1900/L2100 50'-0"30° ERICSSON AIR21 KRC118023-1 B2A-B4P 120°56" x 12" x 8"U1900/G1900 ERICSSON AIR21 KRC118023-1 B2A-B4P 240°56" x 12" x 8"U1900/G1900 - - - - ERICSSON AIR32 KRD901146-1 B66A-B2A 56.6" x 12.9" x 8.7"L1900/L2100 120° ERICSSON AIR32 KRD901146-1 B66A-B2A 56.6" x 12.9" x 8.7"L1900/L2100 240°-(1) ERICSSON 9x18 HCS 40M, ±131'-0"(1) ERICSSON 6x12 HCS 6AWG 40M, ±131'-0"SECTOR ANTENNA FREQUENCY MODEL SIZE (H x W x D) ANTENNA AZIMUTH RAD CENTER RRU / TMA CABLE LENGTH & TYPE A1 A2 A3 A4 RFS APXVAARR24-43-U-NA20 95.9" x 24" x 8.7" 50'-0"L600/L700 30°(1) RRUs 4449 B71 + B12 - B1 B2 B3 B4 C1 C2 C3 C4 - - ERICSSON AIR21 KRC118023-1 B2A-B4P 30° 50'-0"56" x 12" x 8" ERICSSON AIR32 KRD901146-1 B66A-B2A 56.6" x 12.9" x 8.7" U1900/G1900 L1900/L2100 50'-0"30° ERICSSON AIR21 KRC118023-1 B2A-B4P 120° 50'-0"56" x 12" x 8"U1900/G1900 ERICSSON AIR21 KRC118023-1 B2A-B4P 240° 50'-0"56" x 12" x 8"U1900/G1900 ERICSSON AIR32 KRD901146-1 B66A-B2A 56.6" x 12.9" x 8.7"L1900/L2100 50'-0"120° ERICSSON AIR32 KRD901146-1 B66A-B2A 56.6" x 12.9" x 8.7"L1900/L2100 50'-0"240° RFS APXVAARR24-43-U-NA20 95.9" x 24" x 8.7" 50'-0"L600/L700 120°(1) RRUs 4449 B71 + B12 RFS APXVAARR24-43-U-NA20 95.9" x 24" x 8.7" 50'-0"L600/L700 240°(1) RRUs 4449 B71 + B12 (1) ERICSSON 9x18 HCS 40M, ±131'-0"(2) ERICSSON 6x12 HCS 6AWG 40M, ±131'-0"- ----- - - - - - ----- ----- -- ---- -- ---- -- ----A3 A4 B2 B3 C2 C3 50'-0" 50'-0" 50'-0" 50'-0" EXISTING T- MOBILE AIR 32 PANEL ANTENNA TO REMAIN, (TYP. (1) PER SECTOR, (3) TOTAL) EXISTING T- MOBILE AIR 21 PANEL ANTENNA TO REMAIN,(TYP. (1) PER SECTOR, (3) TOTAL) EXISTING SBA 51'-0" HIGH MONOPALM EXISTING MONOPALM FRONDS OUTLINE EXISTING T-MOBILE T-ARM MOUNTED ON EXISTING MONOPALM A1 B1 C1 A2 B4 C4 A3 A4 B2 B3 C2 C3 EXISTING T- MOBILE AIR 32 PANEL ANTENNA TO REMAIN, (TYP. (1) PER SECTOR, (3) TOTAL) EXISTING T- MOBILE AIR 21 PANEL ANTENNA TO REMAIN,(TYP. (1) PER SECTOR, (3) TOTAL) EXISTING SBA 51'-0" HIGH MONOPALM EXISTING MONOPALM FRONDS OUTLINE EXISTING T-MOBILE T-ARM MOUNTED ON EXISTING MONOPALM NEW T-MOBILE RFS PANEL ANTENNA ON NEW MOUNTING FRAME (TYP. (1) PER SECTOR, (3) TOTAL) NEW T-MOBILE RRU 4449 ON EXISTING MOUNTING FRAME (TYP. (1) PER SECTOR, (3) TOTAL) 4 A-6 3 A-6 2 A-6 1 A-6 NOTES: NEW T-MOBILE TOWER EQUIPMENT PAINTED TO MATCH EXISTING MONOPALM6'-0 "TYP.6'-0 "TYP.2'-0 "TYP.2'-0 "TYP.6" EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR A-4 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 NEW AND EXISTING WEST ELEVATIONS NEW WEST ELEVATIONEXISTING WEST ELEVATION 4'3' 2'1' 0" 4' 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"2 4'3' 2'1' 0" 4' 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"1 FINISHED GRADE 0'-0" TOP OF EXISTING SBA MONOPALM ±51'-0" RAD CENTER OF EXISTING T-MOBILE ANTENNAS ±50'-0" TOP OF EXISTING MONOPALM FRONDS ±56'-0" EXISTING T- MOBILE AIR 32 PANEL ANTENNA TO REMAIN, (TYP. (1) PER SECTOR, (3) TOTAL) EXISTING T- MOBILE AIR 21 PANEL ANTENNA TO REMAIN,(TYP. (1) PER SECTOR, (3) TOTAL) EXISTING SBA 51'-0" HIGH MONOPALM EXISTING T-MOBILE T-ARM MOUNTED ON EXISTING MONOPALM EXISTING T- MOBILE 8'-0" HIGH CMU WALL ENCLOSURE 8'-0"EXISTING TREE, TYP. EXISTING T- MOBILE METER EXISTING T- MOBILE KNOX BOX EXISTING T-MOBILE 8'-0" WIDE SITE ACCESS GATE EXISTING CURB FINISHED GRADE 0'-0" TOP OF EXISTING SBA MONOPALM ±51'-0" RAD CENTER OF EXISTING & NEW T-MOBILE ANTENNAS ±50'-0" TOP OF EXISTING MONOPALM FRONDS ±56'-0" EXISTING T- MOBILE AIR 32 PANEL ANTENNA, (TYP. (1) PER SECTOR, (3) TOTAL) EXISTING T- MOBILE AIR 21 PANEL ANTENNA,(TYP. (1) PER SECTOR, (3) TOTAL) EXISTING SBA 51'-0" HIGH MONOPALM EXISTING T-MOBILE T-ARM MOUNTED ON EXISTING MONOPALM EXISTING T- MOBILE 8'-0" HIGH CMU WALL ENCLOSURE 8'-0"EXISTING TREE, TYP. EXISTING CURB NEW T-MOBILE RFS PANEL ANTENNA ON NEW MOUNTING FRAME (TYP. (1) PER SECTOR, (3) TOTAL) NEW T-MOBILE RRU 4449 ON EXISTING MOUNTING FRAME (TYP. (1) PER SECTOR, (3) TOTAL) 4 A-6 3 A-6 2 A-6 1 A-6 NOTES: NEW T-MOBILE TOWER EQUIPMENT PAINTED TO MATCH EXISTING MONOPALM EXISTING T- MOBILE KNOX BOX EXISTING T-MOBILE 8'-0" WIDE SITE ACCESS GATE EXISTING T- MOBILE METER EXISTING SHRUBSEXISTING SHRUBS EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR A-5 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 NEW AND EXISTING NORTH ELEVATIONS NEW NORTH ELEVATIONEXISTING NORTH ELEVATION 4'3' 2'1' 0" 4' 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"2 4'3' 2'1' 0" 4' 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"1 FINISHED GRADE 0'-0" TOP OF EXISTING SBA MONOPALM ±51'-0" RAD CENTER OF EXISTING T-MOBILE ANTENNAS ±50'-0" TOP OF EXISTING MONOPALM FRONDS ±56'-0" EXISTING T- MOBILE AIR 32 PANEL ANTENNA TO REMAIN, (TYP. (1) PER SECTOR, (3) TOTAL) EXISTING T- MOBILE AIR 21 PANEL ANTENNA TO REMAIN,(TYP. (1) PER SECTOR, (3) TOTAL) EXISTING SBA 51'-0" HIGH MONOPALM EXISTING T-MOBILE T-ARM MOUNTED ON EXISTING MONOPALM EXISTING T- MOBILE 8'-0" HIGH CMU WALL ENCLOSURE8'-0"EXISTING TREE, TYP. EXISTING T- MOBILE KNOX BOX FINISHED GRADE 0'-0" TOP OF EXISTING SBA MONOPALM ±51'-0" RAD CENTER OF EXISTING & NEW T-MOBILE ANTENNAS ±50'-0" TOP OF EXISTING MONOPALM FRONDS ±56'-0" EXISTING T- MOBILE AIR 32 PANEL ANTENNA, (TYP. (1) PER SECTOR, (3) TOTAL) EXISTING T- MOBILE AIR 21 PANEL ANTENNA,(TYP. (1) PER SECTOR, (3) TOTAL) EXISTING SBA 51'-0" HIGH MONOPALM EXISTING T-MOBILE T-ARM MOUNTED ON EXISTING MONOPALM 8'-0"EXISTING TREE, TYP. EXISTING T- MOBILE KNOX BOX NEW T-MOBILE RFS PANEL ANTENNA ON EXISTING MOUNTING FRAME (TYP. (1) PER SECTOR, (3) TOTAL) NEW T-MOBILE RRU 4449 ON EXISTING MOUNTING FRAME (TYP. (1) PER SECTOR, (3) TOTAL) 4 A-6 3 A-6 2 A-6 1 A-6 NOTES: NEW T-MOBILE TOWER EQUIPMENT PAINTED TO MATCH EXISTING MONOPALM EXISTING SHRUBS EXISTING T- MOBILE METER EXISTING T- MOBILE 8'-0" HIGH CMU WALL ENCLOSURE EXISTING SHRUBS EXISTING T- MOBILE METER EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR A-6 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 EQUIPMENT DETAILS 1APXVAARR24_43-U-NA20 ANTENNA DETAIL TOP MANUFACTURER: RFS MODEL: APXVAARR24_43-U-NA20 ANTENNA WEIGHT: 128 LBS MOUNTING WEIGHT: 25.3 LBS DIMENSIONS (H x W x D): 95.9" x 24" x 8.7" SIDEFRONT95.9"8.7" 24" 3RRU 4449 DETAIL FRONT TOP SIDE MANUFACTURER: ERICSSON MODEL: RRU 4449 WEIGHT: 74 LBS ±4 LBS DIMENSIONS (H x W x D): 14.95"x13.19"x9.25"14.95"13.19" 9.25" ERICSSON 2ANTENNA MOUNTING DETAIL 4RRU MOUNTING DETAIL POLE MOUNTING BRACKET, TYP. EXISTING 3-1/2" DIA SCHEDULE 40 ANTENNA MOUNTING PIPE 8'-6" MINIMUM LENGTH (TYP) NEW REMOTE RADIO UNIT (RRU), PER PLAN NOTES: 1. FOR POLE DIAMETERS FROM 6" TO 15", ALCATEL-LUCENT CAN SUPPLY A PAIR OF POLE MOUNTING METAL BANDS WITH BOLTING WELDMENT. VARIES W/ ANTENNA TYPE MOUNTING BRACKET & HARDWARE BY ANTENNA MANUFACTURER 2 3/8"Ø MIN. SCH 40 PIPE, VERIFY LENGTH W/ ANTENNA REQUIREMENTS PANEL ANTENNA, VERIFY TYPE W/MANUFACTURER PRIOR TO STARTING CONSTRUCTION 8NOT USED 9NOT USED 6NOT USED7NOT USED 5HYBRIFLEX CABLE 1-1/4"Ø SINGLE MODE FIBER [μm] POWER WIRE CROSS SECTION CABLE TYPE: STRUCTURE FIRE PERFORMANCE: LENGTH: [MM (IN)] HYBRIFLEX LOW INDUCTANCE FLAME RETARDANT 36.57 (120) OUTER DIAMETER NOMINAL MECHANICAL SPECIFICATIONS MINIMUM BENDING RADIUS, SINGLE BEND: [KG/M (LB/FT)] 39 (1.54) 2.52 (1.7) [MM (IN)] 152 (6) 1/1.2 (3.25/4) MINIMUM BENDING RADIUS, MULTI BENDS: RECOMMENDED/MAXIMUM CLAMP SPACING NUMBER OF DC PAIRS DC POWER CABLE SPECIFICATIONS [Ω/KM (Ω/KFT)] [MM² (AWG)] 6 13.3 (6) PVC/NYLON 9.3 (0.365) FOR USE IN TYPE RHC PER UL 2882, PVC/NYLON, RoHS/REACH COMPLIANT SIZE: 1-1/4" [M (FT)] CABLE WEIGHT: [MM (IN)] 254 (10) [M (FT)] MAXIMUM DC-RESISTANCE POWER CABLE 1.4 (0.42) CROSS SECTION OF POWER CABLE DC WIRE JACKET MATERIAL DC CABLE DIAMETER DC CABLE JACKET [MM (IN)] PVC/NYLON DC STANDARDS (MEETS OR EXCEEDS) BREAK-OUT LENGTH [MM (IN)]812.8 DC CABLE SEALING METHOD SEMI-RIGID FLAME-RETARDEND POLYOLEFIN, WITH HOT MELT ADHESIVE ALARM WIRE 18 (9 STANDARD PAIRS), 0.8 MM2 (18), 6AWG UV-PROTECTION INDIVDUAL AND EXTERNAL JACKET CABLE JACKET YES ARMOR SPECIFICATION CORRUGATED ALUMINUMARMOR TYPE MAXIMUM DC-RESISTANCE OF ARMOR [Ω/KM (Ω/KFT)] 0.9 (0.27) DIAMETER CORRUGATED ARMOR [MM (IN)] 36 (1.42) F/O CABLE SPECIFICATIONS F/O CABLE TYPE SINGLE-MODE NUMBER OF F/O PAIRS CORE/CLAD 12 9/125 SECONDARY PROTECTION NOMINAL [μm (IN)]900 (0.035) SINGLE BENDING RADIOUS 137 (5.4)[MM (IN)] F/O STANDARDS (MEETS OR EXCEEDS)UL LISTED TYPE OFNR (UK1666), RoHS COMPLIANT OPTICAL LOSS [dB (KM)]0.5 @ 1310 NM 0.5 @ 1550 NM 0.4 FIBER TERMINATION END 1 DLC CONNECTORS FIBER TERMINATION END 2 DLC CONNECTORS FO BREAK-OUT LEGNTH CABLE SEALING METHOD 939.8 ±50.8 (37 ±2)[MM (IN)] SEMI-RIGID FLAME-RETARDED POLYOLEFIN, WITH HOT MELT ADHESIVE TESTING AND ENVIRONMENTAL STORAGE TEMPERATURE [°C (°F)] -40 TO 70 (-40 TO 158) OPERATION TEMPERATURE [°C (°F)] -40 TO 65 (-40 TO 158) INSTILLATION TEMPERATURE [°C (°F)] -20 TO 65 (-4 TO 149) JACKET SPECIFICATIONS UL2882 TYPE RHC, UL LISTED ALARM WIRE STANDARDS (MEETS OR EXCEEDS)UL STANDARD 1063, 1581 VW-1, MTW OIL AND GASOLINE RES1 SUNRES (CABLE MEETS UL REQUIREMENTS), RoHS/REACH COMPLIANT INSULATION / OUTER JACKET DC ELECTRICAL GROUND WIRE INSULATION / INNER (RED) DC POWER WIRES EXP: 12/31/2020 REV 0 DATE DESCRIPTION BY CHECKED BY: 11/20/18 90% CONSTRUCTION MR IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT IE25790A FAMILY HERITAGE CHURCH 78998 MILES AVE. LA QUINTA, CA 92253 JR G-1 ® CORPORATE OFFICE:8051 CONGRESS AVE. BOCA RATON, FL33487-1307 LOCAL CA OFFICE:510 GOETZ AVE. SANTA ANA, CA 92707 R CA40771-T-01 IE790 12/10/18 100% CONSTRUCTION MR1 GROUNDING DETAILS TYPE SS TYPE TA TYPE VB TYPE PH TYPE GR TYPE PG TYPE GT TYPE GY TYPE NC TYPE LJ TYPE HA TYPE VS TYPE NX1 TYPE ND TYPE XA TYPE GR TYPE GL LUG TYPE PC TYPE RR BOLT GRND. ROD CLAMP2 HOLE LUG "U" BOLT PIPE CLAMP 2 BOLT PARALLEL SPLICER 1 BOLT PARALLEL CLAMP CROSS RUN CLAMP CAST "T" SPLICER UNIVERSAL PIPE CLAMPS 50H2 UNIVERSAL PIPE CLAMPS 75/1.25 1 BOLT PARALLEL CLAMP STANDARD GROUNDING KIT (TYP) (SEE NOTE 7 ON SHEET G-2) GROUNDING BAR, ANDREW PART# UGBKIT-0424-T (TINNED). A LOCKBOX IS REQUIRED AT GRADE TASSCO PART# 351546. ANTENNA HEIGHT WILL DETERMINE NUMBER OF GROUNDING BARS AND THEIR LOCATION ANTENNA CABLE TO BTS, (TYP) 6 AWG STRANDED COPPER CONDUCTOR WITH GREEN, 600V, THWN-2 INSULATION COAX JUMPER REQUIRED PER MANUFACTURER'S RECOMMENDATION OR FOR EASE OF CONNECTION, (TYP) CONNECTOR WEATHER- PROOFING KIT (TYP) FROM LNA (WHEN REQUIRED) 2 AWG TINNED, SOLID COPPER CONDUCTOR EXOTHERMIC WELD TO GROUNDING BUS NEW PANEL ANTENNA (TYP. PER PLAN) NEW 1/2" COAX SECURED WITH APPROVED ATTACHMENTS (TYP) NEW COAXIAL CABLE GROUNDING KIT, GROUND TO EXISTING GROUND BAR(S) AT ANTENNA LEVEL (TYP) NEW REMOTE RADIO UNIT (TYP PER PLAN) 10NOT USED 11NOT USED 12NOT USED 7NOT USED 8NOT USED 9NOT USED 4ANTENNA AND RRU GROUNDING DETAIL 5NOT USED 6NOT USED 1EXOTHERMIC CONNECTION 2MECHANICAL CONNECTION 3ANTENNA GROUNDING BAR EXP: 12/31/2020