Loading...
MA 2019-0006 Davis Property - 78750 Nolan (09.25.2019) September 25, 2019 Allicia Louisa Davis 13021 NE 32nd Pl Bellevue, WA 98005 Dear Ms. Davis: The Design and Development Department has reviewed your Minor Adjustment application (MA 2019-0006), pursuant to Section 9.210.040 of the City of La Quinta Zoning Code. REQUEST: Grant up to a 10% adjustment to decrease the current garage width by 1’ -6”, from 20 ft. to 18 ft. 6 in. to accommodate a third car garage enclosure, per the attached exhibits. DECISION: Approval is granted for the requested adjustment based on the following findings and subject to the conditions of approval listed below: 1. Minor Adjustment 2019-0006 is consistent with the La Quinta General Plan, in that the proposal does not alter the approved land use for the property or affect land use on surrounding similar properties. 2. Minor Adjustment 2019-0006 is consistent with the intent of the La Quinta Zoning Code in that the requested adjustment will be conditioned to comply with all other development standards as required under said Zoning Code. 3. Processing and approval of Minor Adjustment 2019-0006 is in compliance with the California Environmental Quality Act. The adjustment requested falls under CEQA Guidelines Section 15305(a) as a “Minor Alterations in Land Use Limitations” - Class 5 Categorical Exemption. 4. Approval of Minor Adjustment 2019-0002 is not detrimental to the public health, safety and general welfare, nor injurious or incompatible with other properties and land use in the vicinity. The adjustment has no impact on health or safety issues and will not affect physical land use characteristics in the vicinity. CONDITIONS OF APPROVAL: 1. A building permit shall be obtained prior to construction. 2. The proposed construction shall comply with all other development standards as required under the La Quinta Zoning Code. Please be advised that the City only approves three Minor Adjustments per lot, regardless of the percentage of the development standard adjusted. This approval relates only to allowance of the adjustment as stated above and does not imply any entitlement or approval of a building permit for any structures shown on the plans on file. All other development standards of the La Quinta Zoning Code are applicable and shall be adhered to in preparing plans for building plan check. If you have any additional questions, please contact me at 760-777-7069. Sincerely, Carlos Flores, Senior Planner Design and Development Department EXISTING RESIDENCE SETBACK EXISTING GARAGE GARAGE CONVERSION 187.00 S.F. PROPERTY LINE 60.00'PROPERTY LINE 155.60'PROPERTY LINE 111.10'PROPERTY LINE 30.00'PROPERTY LINE 56.95'PRO PE RT Y L INE56.9 5 ' 5'-0" 5'-0"20'-0"25'-0"SETBACKSETBACK SETBACKEXISTING POOL EXISTING SPA N O L A N C I R C L EGAS METERVERIFYMAIN PANEL+/- 26'-3"+/ - 48 ' -1 " 1. ALL WORK,MATERIALS AND METHODS SHALL BE IN CONFORMANCE WITH THE 2016 CBC CODES, 2016 CPC, 2016 CMC AND 2016 CEC CODE EDITIONS. ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND EXISTING CONDITIONS THEREON BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES AND/OR POTENTIAL PROBLEMS TO THE ARCHITECT PRIOR TO PROCEEDING WITH AFFECTED WORK. 3. CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION OF THE DOCUMENTS. 4. PROVIDE PIPE GUARDS AT ALL ABOVE GROUND UTILITY EQUIPMENT AS DICTATED BY GOVERNING AGENCIES. 5. PROVIDE PEDESTRIAN OR VEHICULAR PROTECTION BARRICADES TEMPORARY GUARD RAILS, AND / OR CANOPIES AS REQUIRED BY THE LOCAL AGENCIES OR AS NECESSARY FOR PEDESTRIAN AND VEHICULAR SAFETY. 6. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR COORDINATION AMONG HIS VARIOUS SUBCONTRACTORS. 7. IN THE EVENT OF DISCREPANCIES BETWEEN ANY DRAWINGS AND/OR SPECIFICATIONS, THE MORE COSTLY OR MORE RESTRICTIVE CONDITIONS SHALL BE DEEMED THE CONTRACT REQUIREMENT, UNLESS OTHERWISE STATED IN WRITING, FROM THE DESIGNER. GENERAL CONTRACTOR SHALL COORDINATE ALL UNDERGROUND ITEMS WITH THE PLUMBING, ELECTRICAL, GAS DRAWINGS . CONTRACTOR SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT MANUFACTURERS. 8. GENERAL CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNING, AUTHORITIES AND UTILITIES PRIOR TO COVERING UP ANY WORK REQUIRING INSPECTION. 9. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS WHERE REQUIRED. 10. ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED WITH APPROPRIATE SEALANT MATERIAL. UNLESS OTHERWISE NOTED 11. ALL EXTERIOR AND INTERIOR EXPOSED METAL, TRIM, TREILLAGE,RAILINGS, MOLDING, FRAMES, CASTING, ETC., SHALL BE PAINTED. 12. ALL METALLIC UTILITY LINES SHALL BE CORROSION PROTECTION. 14. ALL CONSTRUCTION AND DETAILS SHALL COMPLY WITH THE CITY OF PALM SPRINGS BUILDING CODE AND ITS ADOPTIONS, AND WITH ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL ORDINANCES. 15. ANY/ALL LUMBER IN CONTACT WITH CONCRETE FLOOR OR FOOTINGS SHALL BE F.G. REDWOOD OR PRESSURE TREATED . 16. ALL FRAMING LUMBER SHALL BE GRADE MARKED WITH QUALITY PER C.B.C. (CALIFORNIA BUILDING CODE) REQUIREMENTS. 17. EACH GENERAL ENGINEERING CONTRACTOR, GENERAL BUILDING CONTRACTOR, AND SWIMMING POOL CONTRACTOR SHALL FURNISH THE CITY WITH A LIST OF EACH SUBCONTRACTOR UNDER HIS CONTROL OR DIRECTION, AND EACH SUBCONTRACTOR SHALL HAVE OBTAINED A BUSINESS LICENSE BEFORE THE FINAL INSPECTION ON A BUILDING OR STRUCTURE SHALL BE GIVEN BY THE BUILDING AND SAFETY DEPARTMENT. (PALM DESERT MUNICIPAL CODE 5.06.010) 18. ACCESSORY DWELLING UNITS (<1,200 SQUARE FEET) NEED NOT TO HAVE FIRE SPRINKLERS, WHETHER ATTACHED OR DETACHED, PROVIDED THE PRIMARY HOME DOES NOT HAVE A FIRE SPRINKLER SYSTEM. SENATE BILL 1069 19EXISTING NON COMPLIANT FIXTURES (TOILETS THAT US MORE THAN 1.6 GALLONS OF WATER PER FLUSH, URINALS THAT USE MORE THAN ONE GALLON OF WATER PER FLUSH, SHOWERHEADS THAT HAVE A FLOW CAPACITY OF MORE THAN 2.5 GALLONS OF WATER PER MINUTE, AND INTERIOR FAUCETS THAT EMIT MORE THAN 2.2 GALLONS OF WATER PER MINUTE) SHALL BE REPLACED. CERTIFICATION OF COMPLIANCE SHALL BE GIVEN TO THE BUILDING INSPECTOR PRIOR TO FINAL PERMIT APPROVAL. CALIFORNIA SB407. 20. COMPLIANCE WITH THE DOCUMENTATION REQUIREMENTS OF THE 2016 ENERGY EFFICIENCY STANDARDS IS NECESSARY FOR THIS PROJECT. REGISTERED, SIGNED, AND DATED COPIES OF THE APPROPRIATE CF1R, CF2R, AND CF3R FORMS SHALL BE MADE AVAILABLE AT NECESSARY INTERVALS FOR BUILDING INSPECTOR REVIEW. FINAL COMPLETED FORMS WILL BE AVAILABLE FOR THE BUILDING OWNER. 21. A LICENSED ENGINEER OR SURVEYOR SHALL STAKE THE PROPERTY CORNERS OF THE SUBJECT LOT. AT THE TIME OF THE UNDERGROUND PLUMBING INSPECTION, AND PRIOR TO CALLING FOR ANY FOOTING INSPECTIONS FOR THESE PROJECTS, THE CONTRACTOR SHALL PROVIDE STRING LINES ALONG THE PROPERTY LINES ADJACENT TO THE PROPOSED WALL LINES OF THE NEW CONSTRUCTION. 22. EACH GENERAL ENGINEERING CONTRACTOR, GENERAL BUIDLING CONTRACTOR, AND SWIMMING POOL CONTRACTOR SHALL FURNISH THE CITY WITH A LIST OF EACH SUBCONTRACTOR UNDER HIS CONTROL OR DIRECTION, AND EACH SUBCONTRACTOR SHALL HAVE OBTAINED A BUSINESS LICENSE BEFORE THE FINAL INSPECTION ON A BUILDING OR STRUCTURA SHALL BE GIVEN BY THE BUILDING AND SAFETY DEPARTMENT. (PALM DESERT MUNICIPAL CODE 5.06.010) PROJECT IS APPROVED UNDER CITY OF LA QUINTA SHEET INDEX PROPERTY OWNER: LOUISA DAVIS 78-750 NOLAN CIRCLE LA QUINTA, CA 92260 PROJECT ADDRESS 78-750 NOLAN CIRCLE LA QUINTA, CA 92260 APN: 604-233-020 LEGAL DESCRIPTION: LOT 189 MB 213/067 TR 23268 PROJECT AREAS LOT SIZE: 8,190 S.F. 0.188 AC. EXISTING RESIDENCE: 1,591.00 S.F. GARAGE CONVERSION: 187.00 S.F. TOTAL LIVING AREA: 1,778.00 S.F. LOT COVERAGE: 26% BUILDING DATA: ZONING: RL OCCUPANCY TYPE: R3/U CONSTRUCTION TYPE: VB FIRE SPRINKLERS: NO EXISTING RESIDENCEYEAR BUILT: 1995 PROJECT DATA 1-800 TWO WORKING DAYS BEFORE YOU DIG 422-4133 Underground Service Alert Call: TOLL FREE YEAR ROUND 7:00AM TO 7:00PM ON WEEKDAYS 8:00AM TO 5:00PM ON SATURDAYS PROHIBITED ON SUNDAYS AND HOLIDAYS. CONSTRUCTION HOURS SCALE: 1/8= 1'-0" ALL EXISTING CONDITIONS SHALL BE VERIFIED BY THE GENERAL CONTRACTOR.. SITE PLAN GENERAL NOTES DEPARTMENT OF CODE COMPLIANCE: ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT BUSINESS LICENCE PRIOR TO PERMIT ISSUANCE PER MUNICIPAL CODE, TITLE 5. ALL CONTRACTORS AND/OR OWNER-BUILDERS MUST SUBMIT CERTIFICATE OF WORKER'S COMPENSATION INSURANCE COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT PER CALIFORNIA LABOR CODE, SECTION 1800. GENERAL CONTRACTORS AND/OR OWNER-BUILDERS SHALL COMPLETE AND SUBMIT A CONTRACTOR'S LIST FROM THE DEPARTMENT OF CODE COMPLIANCE PRIOR TO REQUEST FOR FINAL INSPECTION. DEPARTMENT OF BUILDING AND SAFETY : APPROVED TEMPORARY SANITARY FACILITIES ( I.E. CHEMICAL TOILETS) SHALL BE IN THE CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION ). HEALTH AND SAFETY CODE SECTION 5406. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT OF WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. 2016 CALIFORNIA BUILDING CODE CBC 2016 CALIFORNIA RESIDENTIAL CODE CRC 2016 CALIFORNIA MECHANICAL CODE CMC 2016 CALIFORNIA PLUMBING CODE CPC 2016 CALIFORNIA ELECTRICAL CODE CEC 2016 CALIFORNIA FIRE CODE CFC 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE CALGREEN 2016 CALIFORNIA ENERGY CODE CEC TITLE 24, PART 2, CALIFORNIA ADMINISTRATIVE CODE HANDICAP COMPLIANCE REGULATIONS AND ALL OTHER LOCAL CODES, ORDINANCES AND STATE AMENDMENTS.VICINITY MAP NO.SHEET NAME GENERAL A1.10 TITLE SHEET / SITE PLAN PROJECT SCOPE A1.10 TITLE SHEET - SITE PLAN A2.10 FLOOR PLANS A3.10 ELEVATIONS / DETAILS MEP1.10 MECHANICAL / ELECTRICAL / PLUMBING T24-1 T24 T24-2 T24 T24-3 T24 GARAGE CONVERSION CONVERT 187 SF OF EXISTING GARAGE INTO LIVABLE SF. NEW ELECTRICAL LAYOUT AT GARAGE CONVERSION NEW MECHANICAL SUPPLY AT GARAGE CONVERSION LAUNDRY UNIT RECONFIGURATION A L L D R A W I N G A R E T H E P R O P E R T Y O F D E S E R T D E S I G N C O L L A B O R A T I V E , A N D A R E O N L Y T O B E U S E D A S A N I N S T R U M E N T O F S E R V I C E . T H E S E D R A W I N G S S H A L L N O T BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT THE WRITTEN CONSENT FROM DESERT DESIGN COLLABORATIVE. SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEASE IN AN Y WAY T H E CO P YR IGH T A N D O W N E R S H IP OF D R A W ING S P R O V I S I O N S L I S T E D H E R E I N . STATUS DATE PROJECT # FIRST SUBMITTAL 07/29/2019 19050 SHEET NAME 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D E S E R T C O L L A B O R A T I V E D E S I G N D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S DESIGNER OWNER LOUISA DAVIS ADDRESS 78-750 NOLAN CIRCLE LA QUINTA, CA 92253 PROJECT TYPE GARAGE CONVERSION REVISIONS NO.DESCRIPTION DATE D E S E R T C O L L A B O R A T I V E D E S I G N @ M A I L . C O M 1 1ST PLAN CHECK 08/28/19 1 1 1 PLANNING APPROVAL ADMINISTRATIVE CASE# ____________________ EXHIBIT# ____________________ INITIAL cflores DATE 09/25/2019 4:06:22 PM MA2019-0006 EXISTING WALL TO BE DEMOLISHED EXISTING WALL TO REMAIN - PROTECT IN PLACE WALL LEGEND D01 (E) GARAGE(E) POWDERROOM(E) BEDROOM 1(E) BEDROOM 2(E) MASTER BEDROOM(E) MASTERCLOSET(E) MASTER BATH(E) LIVING ROOM(E) DINING ROOM(E) KITCHEN(E) MORNINGROOM(E) FOYER(E) HALL(E) BATH 1D02 D03 D03 NEW 2X WALL W/ INSULATION PER T24 WALL LEGEND (E) GARAGE(E) POWDERROOM(E) BEDROOM 1(E) BEDROOM 2(E) MASTER BEDROOM(E) MASTERCLOSET(E) MASTER BATH(E) LIVING ROOM(E) DINING ROOM(E) KITCHEN(E) MORNINGROOM(E) FOYER(E) HALL(E) BATH 1(N) BEDROOM 3-4" FROM F.F.100 100 100 100101 102 A C B D E F 01 02 18'-612"10'-812"20'-1"2'-8"2'-512"14'-1112"5'-2" 7'-0"3'-812" 03 04 05 07 08 09 10 11 1213 1415 16 17 G 06 ABOVE H I MIN. GARAGE DIMENSION REQUIRED: 20'-0" MINOR ADJUSTMENT ALLOWS A 10% REDUCTION: 20'-0" - 10% = 18'-0" ACTUAL DIMENSION PROVIDED = 18'-6.5" > 18'0" PER THE CITY OF LA QUINTA, A 10% VARIANCE IS ALLOWED IF APPROVED BY THE CITY THROUGH APPLYING FOR A MINOR ADJUSTMENT D04 D05 4'-0"5'-412"SLOPE SLOPE SLOPE SLOPESLOPE08 A3.10 SYM. 01 WIDTH 4'-0" HEIGHT 4'-0 GLAZING REMARKSTYPE SLIDER WINDOW SCHEDULE U-FACTOR SHGC 02 0'-10"6'-8" TEMPERED SYM. A WIDTH 3'-0" HEIGHT 6'-8" U FACTOR DOOR SCHEDULE TYPE REMARKS SOLID CORE / GLASS 14 S.F. OF GLASS GLAZING TEMPERED B 6'-0"6'-8"LOUVERED C 6'-0"6'-8" D 2'-6"6'-8" E 2'-6"6'-8" F 16'-2"7'-0" SELF CLOSING, SELF LATCHING, SOLID CORE OR LISTED 20 MINUTE ASSEMBLY(E) SOLID CORE (E) SOLID CORE (E) GARAGE FRAME VINYL PROVIDE MINIMUM 100 SQ. IN. OPENING FOR VENTILATION LOUVERED PROVIDE MINIMUM 100 SQ. IN. OPENING FOR VENTILATION FIXEDTEMPEREDVINYL 03 2'-0"5'-0"CASEMEMTTEMPEREDVINYL 04 3'-0"5'-0"TEMPEREDVINYL 05 0'-10"6'-0"TEMPEREDVINYL 06 4'-0"1'-6"VINYL 07 2'-0"5'-0"TEMPEREDVINYL 08 3'-0"5'-0"TEMPEREDVINYL 09 2'-0"5'-0"TEMPEREDVINYL 10 5'-0"3'-0"TEMPEREDVINYL 11 5'-0"5'-0"TEMPEREDVINYL 12 5'-0"5'-2"TEMPEREDVINYL 13 4'-0"4'-0"VINYL 14 3'-0"5'-0"TEMPEREDVINYL 15 3'-0"5'-0"TEMPEREDVINYL 16 4'-0"1'-6"VINYL 17 6'-0"4'-0"TEMPEREDVINYL CASEMEMT SLIDER SLIDER FIXED FIXED GLASS BLOCK SLIDER FIXED SLIDER SLIDER CASEMEMT CASEMEMT CASEMEMT FIXED G 3'-0"6'-8"SOLID CORE / GLASS 14 S.F. OF GLASSTEMPERED H 6'-0"6'-8"SOLID CORE / GLASS 28 S.F. OF GLASSTEMPERED I 6'-0"6'-8"SOLID CORE / GLASS 28 S.F. OF GLASSTEMPERED NOTE 1: LIGHTING REQUIREMENTS =8% OF S.F. VENTILATION REQUIREMENTS =4% OF S.F. (N) GARAGE CONVERSION =187 S.F. 187 S.F. X .08 =14.88 S.F. OF LIGHTING REQUIRED 187 S.F. X .04 =7.48 S.F OF VENTILATION REQUIRED 16 S.F. OF LIGHTING IS PROVIDED AT NEW GUEST BEDROOM 8 S.F. OF VENTILATION IS PROVIDED AT NEW GUEST BEDROOM SEE NOTE 1 FOR LIGHTING AND VENTILATION REQUIREMENTS0.32 0.25 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 0.71 0.73 SHGC 0.32 0.25 0.71 0.73 0.71 0.73 0.71 0.73 EXISTING / DEMOLITION FLOOR PLAN 11/4" = 1'-0" SCALE A2.10 FLOOR PLANS EXISTING UTILITY SINK TO BE REMOVED. CAP ALL ABANDONED UTILITY LINES. EXISTING GARAGE DOOR, DOOR HARDWARE, AND DOOR EQUIPMENT TO BE REMOVED. PREP AREA FOR NEW INFILL FRAMING. EXISTING WASHER / DRYER TO BE RELOCATED. CAP ALL ABANDONED UTILITY LINES. EXISTING FAU TO REMAIN. PROTECT IN PLACE EXISTING WATER HEATER TO REMAIN. PROTECT IN PLACE. SEE DETAIL 10 / MEP1.10 GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2 INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE (AT WALLS). GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY NOT LESS THAN 5/8 INCH TYPE 'X' GYPSUM BOARD. SECTION R302.6 NEW DRYER. SEE DETAIL 6 / MEP1.10 FOR EXHAUST DETAILS NEW WASHER D01 KEYNOTES D02 A L L D R A W I N G A R E T H E P R O P E R T Y O F D E S E R T D E S I G N C O L L A B O R A T I V E , A N D A R E O N L Y T O B E U S E D A S A N I N S T R U M E N T O F SE R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPRODUCED OR MODIFIED IN ANY WAY WITHOUT THE WRITTEN CONSENT FROM DESERT DESIGN COLLABORATIVE. SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEASE IN A N Y WAY T H E CO P YR IGHT A N D O W N E R S H IP O F D R A W INGS P R O V I S I O N S L I S T E D H E R E I N . STATUS DATE PROJECT # FIRST SUBMITTAL 07/29/2019 19050 SHEET NAME 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D E S E R T C O L L A B O R A T I V E D E S I G N D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S DESIGNER OWNER LOUISA DAVIS ADDRESS 78-750 NOLAN CIRCLE LA QUINTA, CA 92253 PROJECT TYPE GARAGE CONVERSION REVISIONS NO.DESCRIPTION DATE D E S E R T C O L L A B O R A T I V E D E S I G N @ M A I L . C O M 1 1ST PLAN CHECK 08/28/19 D03 NEW FLOOR PLAN 21/4" = 1'-0" SCALE 100 101 102 DOOR AND WINDOW SCHEDULE 11/4" = 1'-0" SCALE D04 D05 1 1 1 PLANNING APPROVAL ADMINISTRATIVE CASE# ____________________ EXHIBIT# ____________________ INITIAL cflores DATE 09/25/2019 4:06:50 PM MA2019-0006