Loading...
PG2020-00298/10/21 VICINITY MAP NTS SECTION 27, T.6.S., R.7.E., S.B.B.& M. OWNER/DEVELOPER: SUNRISE LQ, LLC 81,570 CARSONERAS LA QUINTA, CA 92253 PHONE:(760) 777-1776 APPLICANT: SUNRISE LQ, LLC 81570 CARBONERAS LA QUINTA, CA 92253 PHONE:(760) 777-1776 PROJECT SITE ENGINEER: OVER OV OFROM 01 WATSON ENGINEERING 48-725 VERBENA ROAD PALM DESERT, CA 92260 PH:(760) 275-1553 BASIS OF BEARING: THE BASIS OF BEARINGS FOR THIS MAP IS THE SOUTH LINE OF THE SW 1/4 OF SECTION 27. BEING N 89°4747"E. PIL BENCHMARK: BM # P.D. 109-70 ELEV. 527.941 (NAVD 29) 109-70 CHISELED SQUARE ON CANAL BRIDGE SOUTHEAST WING WALL. 2.0 MILES SOUTH ALONG JACKSON ST. FROM HWY. 111. THEN 2.0 MILES WEST ALONG AVENUE 50, 45 FT. WEST OF MADISON ST. AND 18' SOUTH OF AVENUE 50. ASSESSOR'S PARCEL NUMBER: 764-400-031, 030, 035 UTILITY PURVEYORS: WATER - COACHELLA VALLEY WATER DISTRICT: 760-390-2651 SEWER - COACHELLA VALLEY WATER DISTRICT: 760-398-2651 ELECTRIC - IMPERIAL IRRIGATION DISTRICT: 800303-7756 TELEPHONE - FRONTIER COMMUNICATIONS: 800-483-5000 GAS -THE GAS COMPANY: 800-427-2200 CABLE - SPECTRUM: 760 -MO -1312 NOTE: 1. SEPERATE PERMIT REQUIRED FOR BLOCK AND RETAINING WALLS 2. TC (TOP OF CURB) ELEVATIONS AS SHOWN ARE FOR REFERENCE ONLY IN SETTING GRADES UNDERGROUND SERVICE ALERT CALL TOLL FREE Ef ORE y 0 Ct P ®�- 811 SECTION "A" - "A" BLOCK WALL (SEPERATE NTSPERMIT) BUILDING DWELLING J LEGEND: TC INDICATES TOP OF CURB FL INDICATES FLOWLINE EX INDICATES EXISTING HP INDICATES HIGH POINT LP INDICATES LOW POINT GB INDICATES GRADE BREAK FF INDICATES FINISH FLOOR GF INDICATES GARAGE FLOOR PE INDICATES PAD ELEVATION CB INDICATES CATCH BASIN PUE INDICATES PUBLIC UTILITY EASEMENT RNV INDICATES RIGHT OF WAY EP INDICATES EDGE OF PAVEMENT INV INDICATES INVERT OF PIPE ELEVATION FS INDICATES FINISHED SURFACE FG INDICATES FINISHED GRADE TF INDICATES TOP OF FOOTING TW INDICATES TOP OF WALL Q INDICATES CONCRETE INDICATES GARDEN WALL } INDICATES FIRE HYDRANT �) INDICATES MANHOLE [) INDICATES CLEAN OUT x_ BOOP � Z IN. o " J -- iI T- C 10'-1 5' MIN. COVER2 8' BELOW LOWEST SWALE FLOWLINE UNLESS OTHERWISE INDICATED TYPICAL SIDE YARD DETAIL TYPICAL REAR YARD NTS I 1.0% MIN Dl NOTE: 20% MAX WITHIN 5 FT OF HOUSE 2:1 MAX ELSEWHERE IN THE CITY OF LA QUINTA, CALIFORNIA PRECISE GRADING PLAN TRACT 31681-1 PARCELS A, B & C OF LOT LINE ADJUSTMENT NO. 2020-0009 IN SECTION 27, TA.S., R.7.E., S.B.M. \- C EX GOLF COURSE v D r 681-3 GRAPHIC SCALE INDEX MAP DEMOLITION NOTE: EXISTING PARKING LOT IMPROVEMENTS AND 1 INCH = 80 FT EXISTING STRUCTURE SHALL BE REMOVED PRIOR TO ANY GRADING PER THIS PLAN. GOLF COURSE GRADE TO DRAIN TO GOLF COURSE 8"X 8" OPENING BLOCK WALL OMIT 1/2 BLOCK AT FLOWLINE OF SWALE TO PROVIDE OUTLET PER SEPE RATE FOR YARD DRAINAGE PERMIT O SWALE FLOWLINE AT WALL PL ELEV.j WALL FOOTING PER PLAN 1 TYPICAL WALL OPENING NOT TO SCALE r----------------- i I VARIES I 16' MIN. J I a WITH PATIO FRONT LOCATION LI -----------------J SETBACK a we1 IRETURN Z 6' BLOCK WALL WALL 0 30" BLOCK L VARIES LL - _ - WALL 05096 MIN. - - - - - - - - - - - 0_50°6, MIN. - FA is TOP OF FOOTING 1 NOTE: SIDEWALL DETAIL TOP OF FOOTING SHALL BE A MINIMUM OF 0.33' COVER TO A MAXIMUM OF 1.1' COVER. NOT TO SCALE EXPOSED WALL SHALL BE A MINIMUM OF 2.5' TO A MAXIMUM OF 6.6. APPROVED AJ OR ATE CHERI FLORES DATE BUILDING OFFICIAL PLANNING MANAGER GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE STANDARD PLANS OF THE CITY OF U QUINTA AND THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO APPLY TO THE CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT FOR THE NECESSARY PERMITS AND TO BE RESPONSIBLE FOR SATISFACTORY COMPLIANCE FOR ALL CURRENT ENVIRONMENTAL REGULATIONS DURING THE LIFE OF CONSTRUCTION ACTIVITIES FOR THE PROJECT. ADDITIONAL STUDIES AND/OR PERMITS MAY BE REQUIRED. 3, THE CONTRACTOR SHALL OBTAIN ALL PERMITS AS REQUIRED BY THE CITY OF LA QUINTA OR OTHER GOVERNING AGENCIES. 4. THE CONTRACTOR SHALL NOTIFY THE CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT FORTY-EIGHT (48) HOURS PRIOR TO ANY GRADING, BRUSHING OR CLEARING AND EACH PHASE OF CONSTRUCTION AT (760) 777-7048. 5. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. THE CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES. 6. THE CONTRACTOR SHALL HE RESPONSIBLE FOR THE REMOVAL. REPLACEMENT OR RELOCATION OF ALL REGULATORY. WARNING AND GUIDE SIGNS. 7, THE CITY ENGINEER SHALL APPROVE THE DESIGN AND INSTALLATION OF ALL STREET NAME SIGNS, TRAFFIC CONTROL SIGNS. TRAFFIC STRIPING, LEGENDS, AND PAVEMENT MARKERS TYPE AND LOCATION. 8. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH MARKS NOTED ON THE PLANS, OR FOUND DURING CONSTRUCTION. REMOVAL AND REPLACEMENT SHALL BE DONE BY A REGISTERED CML ENGINEER WITH AN R.C.E. NUMBER BELOW 33,966, OR A LICENSED LAND SURVEYOR ONLY. 9. CONSTRUCTION OPERATIONS AND MAINTENANCE OF EQUIPMENT WITHIN ONE HALF MILE OF HUMAN OCCUPANCY SHALL BE PERFORMED ONLY DURING THE TIME PERIODS AS FOLLOWS: OCTOBER IST TO APRIL 30TH: MONDAY THROUGH FRIDAY 7:00 AM TO 5:30 PM MAY 15T TO SEPTEMBER 30TH: MONDAY THROUGH FRIDAY 6:00 AM TO 7:00 PM WORK SHALL BE PROHIBITED ANY TIME ON SUNDAYS OR ON FEDERAL HOLIDAYS. NO REDUCTION OF THE TRAVELED WAY WIDTH SHALL BE PERMITTED ON ANY CITY STREET ON WEEKENDS OR HOLIDAYS, OR WHEN ACTIVE WORK IS NOT BEING DONE, UNLESS PRIOR AUTHORIZATION TO DO SO IS GRANTED BY THE CITY ENGINEER. 10. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF ALL DIRT, MUD AND DEBRIS DEPOSITED ON THEM AS A RESULT OF THE GRADING OPERATION. CLEANING IS TO BE DONE TO THE SATISFACTION OF THE CITY ENGINEER. 11, ALL CONSTRUCTION AREAS SHALL BE PROPERLY POSTED AND LIGHTED IN CONFORMANCE WITH THE CALIFORNIA STATE MANUAL OF WARNING SIGNS. LIGHTS. AND DEVICES FOR USE IN THE PERFORMANCE OF WORK UPON HIGHWAYS IN ORDER TO ELIMINATE ANY HAZARDS. 12. CONSTRUCTION PROJECTS DISTURBING MORE THAN 1 -ACRE MUST OBTAIN A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT. OWNERS/DEVELOPERS ARE REQUIRED TO: A) FILE A NOTICE OF INTENT (NOI) WITH THE STATE WATER RESOURCES CONTROL BOARD (SWRCB); B) PREPARE A STORM WATER POLLUTION PREVENTION PUN (SWPPP); AND C) HAVE A MONITORING PUN FOR THE SITE. THE NPDES IS A NATIONAL PROGRAM TO CONTROL NON -POINT SOURCE POLLUTANTS CARRIED BY STORM WATER. THE PROGRAM IS IMPLEMENTED AND ENFORCED BY THE SWRCB. GRADING NOTES: 1. GRADING SHALL BE IN ACCORDANCE WITH THE ENGINEERED GRADING REQUIREMENTS OF THE UNIFORM BUILDING CODE, LATEST EDITION, AND SOILS REPORT, NO. , DATED: PREPARED BY: STAMEN ENGINEERING, TELEPHONE NO. 760-883-0713 2, THE SOILS ENGINEER AND THE ENGINEERING GEOLOGIST SHALL EXERCISE SUFFICIENT SUPERVISORY CONTROL DURING GRADING TO INSURE COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN THEIR PURVIEW. 3. THE DESIGN CML ENGINEER SHALL EXERCISE SUFFICIENT CONTROL DURING GRADING AND CONSTRUCTION TO ENSURE COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN HIS PURVIEW. 4. DURING EM ORARYUGH DRAIN GEN CONTROL OPERATIONS SHALLAND BE PROVIDED TO CONSTRUCTION PONDINGRWATER AND DAMAGEENT DRAINAGE TO ADJACENT PROPERTY. 5. AFTER CLEARING, EXISTING GROUND SHALL BE SCARIFIED TO A MINIMUM OF 6" ON THE ENTIRE SITE OR AS RECOMMENDED BY THE SOILS REPORT. 6. THE MAXIMUM CUT AND FILL SLOPES SHALL BE 2:1. 7. PADS SHALL BE COMPACTED TO A MINIMUM OF 90% RELATIVE DENSITY PER A.S.T.M. SPECIFICATIONS AND THE ABOVE MENTIONED SOILS REPORT. B. MINIMUM BUILDING PAD DRAINAGE SHALL BE 2%. DRAINAGE SHALL BE A MINIMUM OF 0.3' DEEP AND BE CONSTRUCTED A MINIMUM OF 2' FROM THE TOP OF CUT OR FILL SLOPES. THE MINIMUM SLOPE OF SWALES SHALL BE 0.50%. 9. ALL FILLS SHALL BE COMPACTED TO A MINIMUM OF NINETY (90) PERCENT OF MAXIMUM DENSITY AS DETERMINED BY THE UNIFORM BUILDING CODE SECTION 7010 OR EQUIVALENT AS APPROVED BY THE CITY ENGINEER. FIELD DENSITY SHALL BE DETERMINED IN ACCORDANCE WITH THE UNIFORM BUILDING CODE SECTION 7002. OR EOUNALENT. AS DETERMINED BY THE CITY ENGINEER. 10. ALL STREET SECTIONS ARE TENTATIVE. THE MINIMUM SECTION IS 3" A.C. OVER 4.5" CRUSHED A.B. ADDITIONAL SOIL TEST(S) SHALL BE REQUIRED AFTER ROUGH GRADING TO DETERMINE EXACT SECTION REQUIREMENTS. THE Cltt ENGINEER SHALL APPROVE THE FINAL STREET SECTION. 11. THE CITY ENGINEER WILL REVIEW FOR APPROVAL THE FINAL STREET SECTIONS AFTER SUBMITTAL OF -R- VALUE TESTS FOR ROADWAY SUBBASE. 12. LOCATIONS OF FIELD DENSITY TESTS SHALL BE DETERMINED BY THE SOILS ENGINEER OR APPROVED TEST AGENCY AND SHALL BE SUFFICIENT IN BOTH HORIZONTAL AND VERTICAL PLACEMENT TO PROVIDE REPRESENTATIVE TESTING OF ALL FILL PLACED. TESTING IN AREAS OF A CRITICAL NATURE OF SPECIAL EMPHASIS SHALL BE IN ADDITION TO THE NORMAL REPRESENTATIVE SAMPLINGS. 13. THE FINAL COMPACTION REPORT AND APPROVAL FROM THE SOILS ENGINEER SHALL CONTAIN THE TYPE OF FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING, AND SHALL BE SO NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATION SHALL BE PERFORMED TO VERIFY THE ACCURACY OF THE MAXIMUM DENSITY CURVES USED BY THE FIELD TECHNICIAN. 14. ALL UNDERGROUND FACILITIES. WITH LATERALS, SHALL BE IN PLACE AND INSPECTED PRIOR TO PAVING. INCLUDING BUT NOT LIMITED TO. THE FOLLOWING: SEWER, WATER, ELECTRIC, COMMUNICATIONS. GAS, AND DRAINAGE. 15. THE FINAL UTILITY LINE BACKFILL REPORT FROM THE PROJECT SOILS ENGINEER SHALL INCLUDE AN APPROVAL STATEMENT THAT THE BACKFILL IS SUITABLE FOR THE INTENDED USE. 16. BLOCK WALLS ARE NOT PMT OF THE GRADING PERMIT. PLEASE SUBMIT THESE FOR SEPARATE BUILDING PERMIT(S). 17. THE CONTRACTOR IS RESPONSIBLE TO PREVENT SILT CONTAMINATION OF STORMWATER INFILTRATION FACILITIES DURING CONSTRUCTION OF SUBSEQUENT IMPROVEMENTS BY THE CONTRACTOR. IMMEDIATELY PRIOR TO FINAL ACCEPTANCE OF STORM DRAINAGE RETENTION/INFILTRATION FACILITIES, THE CONTRACTOR SHALL CONDUCT, IN THE PRESENCE OF THE CITY INSPECTOR, A PERFORMANCE TEST DESIGNED TO CLEARLY DEMONSTRATE THE FUNCTIONAL ADEQUACY OF THE FACILITIES. 18. THE CONTRACTOR SHALL PROVIDE WIND EROSION AND DUST CONTROL MEASURES AS REQUIRED BY THE FUGITIVE DUST CONTROL PLAN APPROVED FOR THIS PROJECT. ALL MEASURES SHALL BE TO THE SATISFACTION OF THE CITY. NOTE: UNDERGROUND UTILITIES PRIVATE ENGINEERING NOTE SEAL - CITY APPROVED BY THE CITY OF LA QUINTA SEAL - ENGINEER BENCHMARKIN THE CITY OF LA QUINTA, CALIFORNIA SHEET NO: WORN CONTAINED WITHIN THESE PLANS SHALL ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY ALL UNDERGROUND UTILITIES OR STRUCTURES BM S P.D. 10&"/0 PRECISE GRADING PLAN NOT COMMENCE UNTIL M ENCROACHMENT THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS REPORTED BY THE OWNER OR OTHERS AND TRIOSE WATSON� IJ�j R� R� Dn �1 (� ELEV. 27.Nl(NAVD29) PERMIT MDIOR A GRADING PERMIT HAS BEEN EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION SHOWN ON THE RECORDS EXAMNM ARE INDICATED .,r1FES$I W X11 0J S W G I IN IS LS II I1 I IN W 10&10 CHISELED SOMME ISSUED. AND EXTENT THE OWNER. BY ACCEPTING THESE PLANS OR WITH THEIR APPROXIMATE LOCATION MA EXTENT. W ON CANAL BRIDGE 5 E. FOR THE OWNER. BY ACCEPTING THESE PLANS OR O .0 MLLES B. PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO, PROCEPDING WITH IMPROVEMENTS PURSUANT �o �cT CIVIL ENGINEERING • LAND PLANNING WING WALL.2TRACT 31681-1 PARCELS A B & C THE PRIVATE ENGINEER SIGNING THESE PIANS AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED THERETO,AGREES TO ASSUME LIABILITY AND TO HOLD ti Q M-1261 NM ROAD ALONG JACKSON ST. FROM f IS RESPONSIBLE FOR AWURING THE HARMLESS FOR ANY DAMAGES RESULTING FROM EXISTENCE OF UNDERSIGNED HARMLESS FOR ANY DAMAGES y v P"KMRT CA. 11050 HWY. 111. THEN 2.0 MILES OF LOT LINE ADJUSTMENT ACCURACY MD ACCEPTABILITY OF THE DESIGN UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO RESULTING FROM EXISTENCE OF UNDERGROUND Z M; (TW)215-1553 W. ALONG 0. 45 FT UTILITIES OR STRUCTURES NOT REPORTED TO THE uO'R �mR11 AVE.. . n HEREON. IN THE EVENT OF DISCREPANCIES THE UNDERSIGNED, NOT INDICATED OR SHOWN ON THE RECORDS UNDERSIGNED, NOT INDICATED OR SHOWN ON THE ¢ N0.26662 y WEST OF MADISON ST. NO. 2020-0009 ARISING AFTER COUNTY APPROVAL OR DURING EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED AND 18' S. OF AVE. 50. ENGINEER THE PRIVATE ENGEER SHALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR TO TAKE DUE PRECAUTION Y MEASURES TO BRY MCKINNEV, P.E. RCE NO. 49018 {T E%P. 331-22 Q BE RESPONSIBLE FOR THE DETERMRYNG M STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES PROTECT THE UTILITIES OR STRUCTURES SHOWN AND CITY ENGINEER C V ll FOUND AT THE SITE. IT SHALL BE THE CONTRACTORS MY OTHER UTIUMES OR STRUCTURES FOUND ATTIRE 9 PREP D BY: LLOYD W. WATSON R.C.E. NO. 28662 IN SECTION 27, T.6.5.. R.7. E., $. B.M. F_$HT$. MARK BY DATE DATE ACCEPTABLE SOLUTION AND REVISING THE RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UMITIES OR SITE. IT SHALL BE THE CONTRACTORS RESPONSIBILITY APPR Z 7F CF scALE: PLANS FOR APPROVAL BY THE COUNTY. STRUCTURES CONCERNED BEFORE STARTING WORK. TO NOTIFY THE OWNERS OF THE UTILITIES OR REVISIONS EXP. DATE 9/30M2 DATE: CALL DATE: SCALE AS SHOWN FOR: W O. FILE NO: STRUCTURES CONCERNED BEFORE STARTING WORK. ENGINEER p62Dao -onaq 8/10/21 CALL TOLL FREE t 811 ALL PEHMIT M WOR A GRADING PERMIT HAS BEEN ISSUED, THE PRNATE ENGINEER SIGNING THESE Pf IS RESPONSIBLE FOR ASSURING THE ACCURACY AND ACCEPTABIUTY OF THE DESIGI HEREON. IN THE EVENT OF DISCREPANCIES ARISING AFTER COUNTY APPROVAL OR WRING GONSTRUCTION THE PRIVATE ENGNEER SHA!- BE HALLBE RESPONSIBLE FOR THE DETERMNNG AN ACCEPTABLE SOLUTION AID REVISING THE BEFORE EX GOLF COURSE REVISIONS / ! 442.33 _ d X3.00 TOFF / / BXSee / 4,77 / y NOTE: Q ABANDON EXISTING SEWER LATERAL Q ABANDON EXISTING WATER SERVICE 4 ]YI !G b fi0 IW SCALE: I'- 2W I IN FEET) PLAN 24 COURTYARD DRAINAGE DRAINAGE AREA: 2,432 S.F. 0=0.113 C.F.S. (2 INCHES PER HOUR) 4" PIPE @ 1%: Q=0.25 C.F.S. PLAN 26 COURTYARD DRAINAGE DRAINAGE AREA: 3,657 S.F. Q=0.169 C.F.S. (2 INCHES PER HOUR) 4" PIPE (off 1%: 0=0.25 C.F.S. PVC SCH. 40 X3/8" TO 3M" WASHED ROCK GEOTEXTILE FABRIC BUBBLER BOX DETAIL NTS DRAINAGE CONSTRUCTION NOTES 1O INSTALL 4" PVC SCHEDULE 40 PIPE, MIN. 1% SLOPE OR PER PLAN 02 INSTALL NDS PART NO. 13 ROUND GRATE IN GRASS AREAS OR NDS PART NO, 75 ATRIUM GRATE IN PLANTER AREAS, OR APPROVED EQUAL Q CONSTRUCT DRAINAGE EMITTERBUBBLER BOX PER DETAIL ON THIS SHEET ® INSTALL 4" CAP (1) INSTALL NDS PART NO. 9208 SQUARE GRATE, OR APPROVED EQUAL CITY APPROVED BY THE CITY OF LA QUINTA SEAL - ENGINEER BENGHMARK: ESS/QL_ -L,FFF-9� 6' (0� w 0L) a 1111 LS (\I V LS Uli L ISI LlU OVl ENiiIAEIRiC LAND PLANNING BM*P.D. 109-70 109-70C27.941 (NAVD29) ON CHISELDGE S.E. IXJ CANAL BRIDGE S.E. wING WAU-. 2.9 MILES S. _ OJ TJ y v Z /mT0 NO. 28862 A l% EXP. 3-31-22 {T . CMV �P 9)F �1 bTl6 SNL qGp PNN pEgAT. G �6p R! I150I ZJS-ISpi KONG JACKSON ST. FROM HWY. 111. THEN 2.0 MALES W. ALONG AVE. W, 45 Ff. WEST OF MADISON ST. ANDIVS.OFAVE.50. BBRYA19 MCKIRNEY, P.E. RCE NO.49418 CITY ENGINEER EXP. DATE 9/3022 DATE: 4.(/ 2O PREPARED BY: LLOYD W. WATSON RC.E NO.26882 DATE:I�LB/LO SCALE SCALE AS SHOWN IN THE C17Y OF LA QUINTA, CALIFORNIA PRECISE GRADING PLAN FOR TRACT 31681-1 PARCELS A, B & C OF LOT LINE ADJUSTMENT NO. 2020-0009 IN SECTION 27, T.S.S., R.7.E., S.B.M. W.O. FILE NO: Q 6 aol.o - 00-k-9 2