Loading...
99049GENERAL NOTES 1. ALL WORK SHALL BE IN DONE IN ACCORDANCE WITH THE STANDARD PLANS OF THE CITY OF LA QUINTA AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION, AND RIVERSIDE COUNTY STANDARDS AND SPECIFICATIONS ORDINANCE NO, 461, LATEST EDITION. 2, THE CONTRACTOR SHALL OBTAIN ALL PERMITS AS REQUIRED BY THE CITY OF LA QUINTA OR OTHER GOVERNING AGENCIES. 3, THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, REPLACEMENT OR RELOCATION OF ALL REGULATORY, WARNING AND GUIDE SIGNS. 5. STREET NAME SIGNS AND TRAFFIC CONTROL SIGNS, TYPE AND LOCATION SHALL BE APPROVED BY THE: CITY ENGINEER. TRAFFIC STRIPING, LEGENDS AND PAVEMENT MARKERS, TYPE AND LOCATIONS SHALL BE APPROVED BY THE CITY ENGINEER. 6. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH MARKS NOTED ON THE PLANS, OR FOUND DURING CONSTRUCTION. REMOVAL AND REPLACEMENT SHALL BE DONE BY A REGISTERED CML ENGINEER WITH AN R.C.E. NUMBER BELOW 33,966, OR A LICENSED LAND SURVEYOR ONLY, 7. GRADING SHALL BE IN ACCORDANCE WITH THE ENGINEERED GRADING REQUIREMENTS OF THE UNIFORM BUILDING CODE, LATEST EDITION, AND SOILS REPORT 544-8133 DATED: DECEMBER 31, 1998. PREPARED BY: SLADDEN ENGINEERING In the City of La Quinta, County of Riverside, State of California "Greg Norman Course" Street Improvement Plans Tract No. 29136 52nd AVENUE 53rd AVENUE 0 54th AVENUE PGA WEST PROJECT SITE AIRPORT B WEISKOPF 58th AVENUE VICINITY MAP NOT TO SCALE 8, THE CONTRACTOR SHALL NOTIFY THE CITY PUBLIC WORKS INSPECTOR 48 HOURS PRIOR TO ANY GRADING, BRUSHING OR CLEARING AND EACH PHASE OF CONSTRUCTION AT (760) 7777075 AND 48 HOURS PRIOR TO REQUIRING INSPECTIONS. 9. DURING ROUGH GRADING OPERATIONS AND PRIOR TO CONSTRUCTION OF PERMANENT DRAINAGE STRUCTURES, TEMPORARY DRAINAGE CONTROL SHALL BE PROVIDED TO PREVENT PONDING WATER AND DAMAGE TO ADJACENT PROPERTY. 10. CONSTRUCTION OPERATIONS AND MAINTENANCE OF EQUIPMENT WITHIN ONE HALF MILE OF HUMAN OCCUPANCY SHALL BE PERFORMED ONLY DURING THE TIME PERIODS AS FOLLOWS: OCTOBER 1ST TO APRIL 30TH: MONDAY -FRIDAY 7:00 AM TO 5:30 PM SATURDAY 8:00 AM TO 5:00 PM MAY 1ST TO SEPTEMBER 30TH: MONDAY -FRIDAY 6:00 AM TO 7:00 PM SATURDAY 8:00 AM TO 5:00 PM WORK SHALL BE PROHIBITED ANY TIME ON SUNDAY OR FEDERAL HOLIDAY. 11. AFTER CLEARING EXISTING GROUND SHALL BE SCARIFIED TO A MINIMUM OF 6" ON THE ENTIRE SITE OR AS RECOMMENDED BY SOILS REPORT. 12. MAXIMUM CUT AND FILL SLOPES = 2:1. 13. PADS SHALL BE COMPACTED TO A MINIMUM OF 90% RELATIVE DENSITY PER A.S.T.M. SPECIFICATIONS AND ABOVE MENTIONED SOILS REPORT. 14. MINIMUM BUILDING PAD DRAINAGE SHALL BE 2%. DRAINAGE SWALES SHALL BE A MINIMUM OF 0,3' DEEP AND CONSTRUCTED A MINIMUM OF 2' FROM THE TOP OF CUT OR FILL SLOPES MINIMUM. SLOPE OF SWALES SHALL BE 0.50%. 15. ALL FILLS SHALL BE COMPACTED TO A MINIMUM OF NINETY (90) PERCENT OF MAXIMUM DENSITY AS DETERMINED BY UNIFORM BUILDING CODE SEC. 7010 OR EQUIVALENT AS APPROVED BY THE CITY ENGINEER, FIELD DENSITY SHALL BE DETERMINED IN ACCORDANCE WITH THE UNIFORM BUILDING CODE SEC. 7002, OR EQUIVALENT, AS DETERMINED BY THE CITY ENGINEER. 16., ALL STREET SECTIONS ARE TENTATIVE THE MINIMUM SECTION IS 3" A.C./4.5" C.A.B. ADDITIONAL SOIL TEST SHALL BE REQUIRED AFTER ROUGH GRADING TO DETERMINE EXACT SECTION REQUIREMENTS. CITY ENGINEER TO APPROVE FINAL STREET SECTION. 17. LOCATIONS OF FIELD DENSITY TEST SHALL BE DETERMINED BY THE SOIL ENGINEER OR APPROVED TESTING AGENCY AND SHALL BE SUFFICIENT IN BOTH HORIZONTAL AND VERTICAL PLACEMENT TO PROVIDE REPRESENTATIVE TESTING OF ALL FILL AND PLACED. TESTING IN AREAS OF A CRITICAL NATURE OF SPECIAL OF ALL FILL PLACED. TESTING IN AREAS OF CRITICAL NATURE OF SPECIAL EMPHASIS SHALL BE IN ADDITION TO THE NORMAL REPRESENTATIVE SAMPLINGS, 18. ALL UNDERGROUND FACILITIES, WITH LATERALS, SHALL BE IN PLACE AND INSPECTED PRIOR TO PAVING, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: SEWER, WATER, ELECTRIC, GAS AND DRAINAGE. 19. THE FINAL UTILITY LINE BACKFILL REPORT FROM THE PROJECT SOIL ENGINEER SHALL INCLUDE AN APPROVAL STATEMENT THAT THE BACKFILL IS SUITABLE FOR THE INTENDED USE. 20, THE FINAL COMPACTION REPORT AND APPROVAL FROM THE SOILS ENGINEER SHALL CONTAIN THE TYPE OF FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING AND SHALL BE SO NOTED FOR EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATION SHALL BE PERFORMED TO VERIFY THE ACCURACY OF THE MAXIMUM DENSITY CURVES USED BY THE FIELD TECHNICIAN. 21. ALL TRAVELED WAYS MUST BE CLEANED DAILY OF ALL DIRT, MUD, AND DEBRIS DEPOSITED ON THEM AS A RESULT OF THE GRADING OPERATION. CLEANING IS TO BE DONE TO THE SATISFACTION OF THE CITY ENGINEER. 22. BLOCK WALLS ARE NOT PART OF THE GRADING PERMIT. SUBMIT FOR SEPARATE BUILDING PERMIT, 23. ALL CONSTRUCTION AREAS SHALL BE PROPERLY POSTED AND LIGHTED IN CONFORMANCE WITH THE STATE MANUAL OF WARNING SIGNS, LIGHTS AND DEVICES FOR USE IN THE PERFORMANCE OF WORK UPON HIGHWAYS, IN ORDER TO ELIMINATE ANY HAZARDS. 24. THE SOILS ENGINEER AND ENGINEERING GEOLOGIST SHALL EXERCISE SUFFICIENT SUPERVISORY CONTROL DURING GRADING TO INSURE COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN THEIR PURVIEW. 25, THE CITY ENGINEER WILL REVIEW FOR APPROVAL THE STREET SECTIONS AFTER SUBMITTAL OF "R" VALUE TESTS FOR ROADWAY SUBBASE, 26.. THE DESIGN CIVIL ENGINEER SHALL EXERCISE SUFFICIENT CONTROL DURING GRADING AND CONSTRUCTION TO INSURE COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODE WITHIN HIS PURVIEW. 27. THE CONTRACTOR IS RESPONSIBLE TO PREVENT SILT CONTAMINATION OF STORMWATER INFILTRATION FACILITIES DURING CONSTRUCTION OF SUBSEQUENT IMPROVEMENTS BY THE CONTRACTOR. IMMEDIATELY PRIOR TO FINAL ACCEPTANCE OF STORM DRAINAGE RETENTION/INFILTRATION FACILITIES, THE CONTRACTOR SHALL CONDUCT, IN THE PRESENCE OF THE CITY INSPECTOR, A PERFORMANCE TEST DESIGNED TO CLEARLY DEMONSTRATE THE FUNCTIONAL ADEQUACY OF THE FACILITIES. 28. THE CONTRACTOR SHALL PROVIDE WIND EROSION AND DUST CONTROL MEASURES AS REQUIRED BY THE FUGITIVE DUST CONTROL PLAN APPROVED BEFORE THIS PROJECT. SCALE 400' II -I4 110. 1v767 Ca 1RRF01,-1 D To 1R -TTAG-1" NO . 'LcI55-7 CONSTRUCTION NOTES & QUANTITIES 0 CONSTRUCT 6" CONCRETE WEDGE CURB PER DETAIL ON SHEET 2 29,170 L.F. ® CONSTRUCT TYPE "D" CURB ONLY PER RIV. CO, STD. DWG. 204 (' C.F.) 806 L.F. ® CONSTRUCT CURB TRANSITION PER RIV, CO, STD. DWG. 211 ® INSTALL 3" A.C. OVER 4.5" C.A.B. AUSTRALIAN DRIVE 505,908 S.F. NOTE: ALL STORM DRAINS, CATCH BASINS AND LOCAL DEPRESSIONS TO BE CONSTRUCTED PER MASS GRADING PLAN FOR SPECIFIC PLAN 90-015, THE NORMAN COURSE. AIRPORT BOULEVARD INDEX MAP SCALE 1"= 400' PAVING NOTES 1. ALL UNDERGROUND FACILITIES, INCLUDING SERVICE LATERALS, SHALL BE IN PLACE WITH TRENCHES COMPACTED AND TESTED PRIOR TO BASE GRADE INSPECTION AND PAVING. THE CONTRACTOR SHALL SUBMIT WRITTEN EVIDENCE TO THE CITY ISSUED BY THE RESPECTIVE UTILITY PURVEYOR INDICATING THE SUBSURFACE PORTION OF THEIR UNDERGROUND FACILITIES HAVE BEEN INSTALLED AND ACCEPTED. 2. A SEPARATE PERMIT IS REQUIRED FOR ALL EXCAVATIONS WITHIN THE EXISTING ROADWAYS AND TRAVELWAYS. LANE CLOSURES AND DETOURS SHALL BE POSTED, DELINEATED AND LIGHTED IN CONFORMANCE WITH THE CALTRANS' "MANUAL OF TRAFFIC CONTROLS FOR CONSTRUCTION AND MAINTENANCE WORK ZONES" AND ANY ADDITIONAL REQUIREMENTS DEEMED NECESSARY BY THE CITY ENGINEER. 3. ASPHALT, CONCRETE PAVING, EXCEPT FOR OVERLAYS, SHALL BE INSTALLED IN TWO (2) OR MORE COURSES WITH MIX DESIGNS THAT CONFORM TO SECTION 203-6.3.2 OF THE STANDARD SPECIFICATIONS (GREEN BOOK) NOTED AS FOLLOWS: WEARING COURSE (UPPER COURSE): C2 -AR -4000 BASE COURSE (LOWER COURSES): B -AR -4000 THE WEARING COURSE SHALL BE 0.1 FEET THICK; THE BASE COURSE(S) SHALL CONTAIN THE BALANCE OF THE REQUIRED ASPHALT CONCRETE THICKNESS. SEVEN (7) DAYS PRIOR TO COMMENCEMENT OF PAVING OPERATIONS, THE CONTRACTOR SHALL SUBMIT FOR CITY APPROVAL A COMPLETE PROPOSED MIX DESIGN IDENTIFYING THE MIX CHARACTERISTICS SUCH AS: AGGREGATE GRADATIONS, VOIDS IN MINERAL AGGREGATE (VMA), AIR VOIDS, AND S -VALUE FOR VARIOUS OIL CONTENTS FOR EACH MIX, 5. NEW IMPROVEMENTS THAT JOIN EXISTING IMPROVEMENTS SHALL JOIN OR MATCH IN A MANNER SATISFACTORY TO THE CITY ENGINEER. CONSTRUCTION OPERATIONS REQUIRED TO ACHIEVE A SAFE, DURABLE, AESTHETICALLY PLEASING TRANSITION BETWEEN THE NEW AND EXISTING IMPROVEMENTS MAY INCLUDE SAWING CUTTING, REMOVAL, REPLACEMENT, CAPPING, AND/OR COLD PLANING, AS NEEDED. TYPICAL SECTIONS: SEE SHEET 6, ALL MANHOLES AND VALVE BOX FRAMES SHALL BE ADJUSTED TO FINAL GRADES AFTER PAVEMENT INSTALLATION IS COMPLETED. 7. THE CURB SHALL BE ETCHED OR STAMPED SHOWING UTILITY SERVICE LATERAL LOCATIONS AS FOLLOWS: "5" FOR SEWER, "G" FOR GAS, AND "E" FOR ELECTRICAL POWER. SIGNING & STRIPING NOTES: KSL L AND CORPORATION 55-- 920 PGA Boulevard (760) 564 1088 La Quinta, CA 92253 FAX (760) 564-7131 BASIS OF BEARING THE BEARINGS SHOWN HEREON ARE BASED ON THE EASTERLY LINE OF LOT 11, SHOWN AS N 02'25'17" W PER TRACT NO. 21643 FILED IN BOOK 203, PAGES 37 THROUGH 50 OF MAPS RECORDS OF RIVERSIDE COUNTY, CALIFORNIA. UNDERGROUND UTILITIES 4. A TACK COAT SHALL BE APPLIED TO EXISTING PAVEMENT, P.C.C. SURFACES AND THE A.C. BASE COURSE, IF TRAFFIC HAS DRIVEN ON IT. THE TACK COAT SHALL BE SLOW SEI LING ANIONIC EMULSIFIED ASPHALT TYPE "SS -1H" CONFORMING TO SECTION 203-3 OF THE STANDARD SPECIFICATIONS. THE LIQUID ASPHALT SHALL BE GRADE 60-70 AND APPLIED AT THE RATE OF 0.1 GAL/YD. AB 73 REQUIRES EVERY PERSON PLANNING TO CONDUCT EXCAVATION NOTIFY A REGIONAL NOTIFICATION CENTER AT LEAST TWO PRIOR TO EXCAVATION AND, IF PRACTICAL, THE AREA TO BE EXCAVATED SHALL BE DELINEATED. A VERIFICATION NUMBER WILL BE GIVEN UPON SUCH NOTIFICATION WITHOUT WHICH ANY PERMIT OR DIRECTIVE GIVING PERMISSION TO EXCAVATE SHALL BE INVALID. VERIFICATION NUMBERS EXPIRE IN 14 DAYS. FOR BEST COMMUNICATION, PERSONS PERFORMING EXCAVATION SHOULD MEET THE UTILITY COMPANIES' AT THE JOB SITE. FOR MORE INFORMATION YOU CAN CONTRACT THE LOCAL REGIONAL INFORMATION CENTER. Li S CONSTRUCTED" /.9/X` STANLEY C. ORSE DA E UNDERGROUND SERVICE ALERT 3030 SATURN STREET, SUITE 200 BREA, CA 92621 1-(800) 442-4133 RACT NO. 29136 z UNDERGROUND UTILITIES UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH T 1 E.1R APPROXIMATE LOCATION AND E\TENT., THE OWNER, BY ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO, AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED, NOT INDICATED OR SHOWN ON THE RECORDS EXAMINED, THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK, PRIVATE ENGINEERING NOTE APPROVED BY: CI OF LA QUINTA CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OR CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FUTURE AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL, 1-14 I eZ TRAcT NO. 1-C7 REVISIONS DESIGNED BY: DRAWN BY: No. 20596 Exp, 9-30-01 eIVIL CHRIS A. VOLT" R.C.E. j,�250 PREPAif ►.' ND EXP. DATE: 6/30/01 CONSULTING $MDS DOKICH MORSE • 79-799 Old Avenue 52 La Quinta, CA 92253 EMAIL • SCHULTZ (760) 771-4013 FAX 771-4073 rndslaquinta@mdsconsulting.net IN THE CITY OF LA QUINTA, STATE OF CALIFORNIA STREET IMPROVEMENT PLANS TRACT NO. 29136 ALi THE RECTION OF: APPR. CHECKED BY: STANLEY C. MORSE R.C.E. 20596 EXP. DATE: 9/30/01 PLANNING ENGINEERING • SURVEYING ENCH MARK: PD -103-3--70 FD. 1 1/4" 0.D.I.P. FILLED W/CONC, IN 5" 0,D, CONC, COLLAR DN. 0.6', 330' NORTH OF COL, INT. OF WASHINGTON STREET & 52nd AVENUE & 6.2' SOUTH OF PQ.989270. ELEV. 540,110 CONTOUR DATUM IS SEA LEVEL PLUS 500 FEET TO AVOID NEGATIVE NUMBERS. MPROVEMEN Greg Norman Course S 112 SECTION 15 T6S R7E S.B.M. KS LAND CORPORATION W.O. NO: W cc co 01,E-99 , 338 \ 1MPL 4NS \ T PP -01