Loading...
MUP 2021-0023 Bella at Piazza Serena Model Home & Sales Office (03.03.2022)March 3, 2022 Mr. Edgar Gomez Richmond American Homes 391 N. Main Street Suite 205 Corona, CA 92880 SUBJECT: MINOR USE PERMIT 2021-0023 BELLA AT PIAZZA SERENA MODEL HOME COMPLEX AND SALES OFFICE Dear Mr. Gomez: The City of La Quinta Design and Development Department has reviewed and approved Minor Use Permit 2021-0023, for a temporary sales office and model home complex within the Piazza Serena development, subject to the information on file and attached and the following conditions of approval: Planning 1.The model home site and temporary sales office shall be permitted to remain for two (2) years, beginning from the date of this approval, unless a time extension is applied for and granted by this Department. The Design and Development Director may extend the permit for up to one year, upon written request from the property owner. No fee will be charged to extend this permit. 2.The following advertising devices or activities are expressly prohibited within or outside the project: banners, balloons, portable trailer signs, or human indicators/sign twirlers. Permitted signage can be found in LQMC Section 9.60.240. 3.ADA accessible route(s) from the sales office to and throughout the model complex area shall be provided and maintained as may be required by the Public Works Department and the Building Division. Fire 4.Construction Permits Fire Department Review: Submittal of construction plans to the Office of the Fire Marshal for development, construction, installation and operational use permitting will be required. Final fire and life safety conditions will be addressed when the Office of the Fire Marshal reviews these plans. These conditions will be based on occupancy, use, California Building Code (CBC), California Fire Code, and related codes, which are in effect at the time of building plan submittal. 5. Addressing: All commercial buildings shall display street numbers in a prominent location on the address side and additional locations as required. Ref. CFC 505.1 and County of Riverside Office of the Fire Marshal Standard #07-01 6. Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. Contact a certified extinguisher company for proper placement and spacing of equipment. Building 7. A building shall be obtained prior to construction. The proposed construction shall comply with all other development standards as required under the La Quinta Zoning Code. Applicant shall also adhere to the applied Precise Grading permit PG2021-0037. The City may elect to add Conditions to this application request to mitigate any problems that arise not previously addressed herein. If you have any questions, please contact me at (760) 777-7086. Sincerely, Sijifredo Fernandez Associate Planner Design and Development DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER SMP SMP SMP TITLE SHEET 177-TL TL 1N.T.S.KEYMAP LEGEND ATRIUM DRAIN ALIGN BOND BEAM ELEVATION CATCH BASIN TOP OF GRATE ELEVATION FLOW LINE BOTTOM OF STEP BOTTOM OF WALL TOP OF FOOTING ELEVATION GARAGE FLOOR ELEVATION DIAMETER GRADIENT IN PERCENTAGE CATCH BASIN FINISH FLOOR ELEVATION FINISH GRADE FINISH SURFACE HIGH POINT INVERT ELEVATION LOW POINT ON CENTER PAD ELEVATION TOP OF STEP TOP OF WALL SHEET LOCATION SECTION REFERENCE SHEET LOCATION DETAIL REFERENCE BERM - BUILT-UP EXISTING CONTOUR PROPOSED CONTOUR TURF DRAIN DECK DRAIN DRAINAGE PIPE DIRECTION OF FLOW GRADE BREAK RIDGE 31 31 GB R 4:1 1.0% INV BB CB TG OC TS FS FL LP HP BS FG CB BW TF TW GF O PE FF BEGINNING OF CURB RADIUS END OF CURB RADIUS EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PLANTING AREA TYPICAL MINIMUM BOTTOM OF CURB EXPANSION JOINT HEADER LANDSCAPE ARCHITECT MAXIMUM MASTIC JOINT REDWOOD SAW CUT SCORE JOINT TOP OF CURB PA TYP MJ MAX EJ RDWD MIN LA HDR SJ SC R RADIUS (33.60) 33.60 ECR BC TC BCR HT HEIGHT LOCATION MAP CONSTRUCTION NOTES AND LEGEND NOTES VICINITY MAP SHEET INDEX SUBMITTED FOR APPROVAL CONSTRUCTION SET ISSUED RELEASED FOR BID APPROVED REVISIONS RATIO: 4' HORIZONTAL DISTANCE PER 1' OF VERTICAL HEIGHT LANDSCAPE GRADE CONSULTANTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, TRANSPORTATION, MATERIALS, AND SERVICES NECESSARY TO FURNISH AND INSTALL ALL CONSTRUCTION ELEMENTS AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 2. ALL WORK SHALL BE PERFORMED BY A CALIFORNIA LICENSED CONTRACTOR. 3. CONSTRUCTION AND INSTALLATION OF ALL LANDSCAPE ITEMS SHALL BE ACCORDING TO STATE, COUNTY AND LOCAL CODES, ORDINANCES AND UP TO CAL-OSHA SAFETY ORDERS REGARDING PERFORMANCE OF WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH THE NATURE AND LOCATION OF ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. THE CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ALL COSTS INCURRED DUE TO DAMAGE AND/OR REPLACEMENT OF SAID UTILITIES, INCLUDING DELAYS. 5. ANY DISCREPANCIES BETWEEN THE FIELD CONDITIONS AND THE CONTRACT DOCUMENTS AND/OR THE DESIGN INTENT AFFECTING THE SUCCESSFUL COMPLETION AND COST OF THE PROJECT SHALL BE REPORTED TO THE OWNER (JOB SUPERINTENDENT) AND LANDSCAPE ARCHITECT IMMEDIATELY. ALL WORK RELATED TO THE PROBLEM AREA SHALL CEASE UNTIL THE DISCREPANCIES HAVE BEEN RESOLVED BY THE OWNER (JOB SUPERINTENDENT) OR LANDSCAPE ARCHITECT IN WRITING. ANY CONTINUATION OF WORK PRIOR TO THE RESOLUTION OF DISCREPANCIES IS AT THE CONTRACTOR'S RISK AND EXPENSE. 6. ALL SHRUBS AND GROUND COVER SHALL EQUAL OR SURPASS "MONROVIA NURSERY" STANDARDS FOR SIZE AND QUALITY (www.monrovianursery.com) 7. ALL WORK SHALL COMPLY WITH THE CITY OF LA QUINTA STANDARDS FOR LANDSCAPE DEVELOPMENT. 8. THE PLANT MATERIAL SUPPLIER AND/OR LANDSCAPE CONTRACTOR SHALL PROVIDE GUARANTEED EVIDENCE TO THE CITY LANDSCAPE INSPECTOR THAT ALL PLANT MATERIAL IS CONSISTENT WITH THE APPROVED PLANT LEGEND CONSIDERING GENUS, SPECIES, CULTIVARS, AND SIZE SPECIFIES. ALL PLANT MATERIAL NOT CONSISTENT WITH THE PLANT LEGEND MAY BE REJECTED. 9. ALL REVISIONS AND CHANGE ORDERS TO THE APPROVED LANDSCAPE ARCHITECTURAL PLANS AND SPECIFICATIONS ARE SUBJECT TO THE REVIEW AND APPROVAL OF THE CITY LANDSCAPE ARCHITECT BEFORE WORK MAY CONTINUE. MINOR CHANGES ARE TO BE E-MAILED TO THE CITY LANDSCAPE ARCHITECT AND THE CITY LANDSCAPE INSPECTOR. MAJOR CHANGES ARE TO BE DONE WITH TWO REVISED BOND COPIES BEING SENT TO THE CITY WITH NOTIFICATION GIVEN TO THE LANDSCAPE INSPECTOR. 10.CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT BEFORE START OF CONSTRUCTION AT (800) 422-4133. AN ENCROACHMENT PERMIT IS REQUIRED TO VERIFY EXISTING LOCATION OF UTILITIES. 3 4 5 6 7 2 11 Please note the following principles of design utilized on this project directed specifically as conserving water and improving the efficiency of the irrigation system: All head spaced head to head 100% of manufacturers recommended radius. All sprinkler heads utilize matched precipitation nozzles and check valves. All sprinkler heads utilize pressure compensating screens. Triangular spacing utilized for head layout throughout irrigation system. Irrigation zones separated by plant material types. Irrigation zones separated by exposure and orientation. Utilization of irrigation system master valve. Utilization of irrigation system flow sensor. Utilization of rain shut-off device connected to irrigation controller. Utilization of controller with water budgeting feature. IRRIGATION SYSTEM SHALL BE TESTED AND MAINTAINED ON A MONTHLY BASIS BY THE MAINTENANCE STAFF. AN IRRIGATION AUDIT, IN COMPLIANCE WITH THE STATE OF CALIFORNIA LANDSCAPE WATER MANAGEMENT PROGRAM, SHALL BE PERFORMED BY A CERTIFIED IRRIGATION AUDITOR PRIOR TO TURNOVER OF PROJECT AND EVERY 5 YEARS THEREAFTER. THE REGULAR MAINTENANCE SCHEDULE COUPLED WITH THE AUDITS SHOULD HELP TO MAINTAIN THE IRRIGATION EFFICIENCY AS INTENDED IN THE DESIGN Statement of Water Conservation : TL TITLE SHEET CL-1 & CL- 2 CONSTRUCTION LAYOUT PLAN CD-1 & CD-4 CONSTRUCTION DETAILS CN-1 CONSTRUCTION SPECIFICATIONS IR-1 & IR-2 IRRIGATION LAYOUT PLAN ID-1 IRRIGATION LEGEND & CALCS ID-2 IRRIGATION DETAILS ID-3 IRRIGATION SPECIFICATIONS PT-1 & PT-2 TREE & VINE PLANTING PLAN PS-1 & PS-2 SHRUB PLANTING PLAN PD-1 PLANTING DETAILS PN-1 PLANTING SPECIFICATIONS SHEET NO. SHEET DESCRIPTION NOTE: THIS PROJECT COMPLIES WITH CHAPTER 19.08 WATER EFFICIENT LANDSCAPE REQUIREMENTS. ARCHITECT WILLIAM HEZMALHALCH ARCHITECTS, INC. 2850 REDHILL AVE, STE 200 SANTA ANA, CA, 92705 PHONE: (949) 250-0607 ext 8740 FAX: (949) 250-1529 LANDSCAPE ARCHITECT SUMMERS MURPHY & PARTNERS, INC. 34197 COAST HIGHWAY - SUITE 200 DANA POINT, CA 92629 PHONE: (949) 443-1446 x231 EMAIL: JPORZUCZEK@SMPINC.NET CONTACT: JOHN PORZUCZEK OWNER / DEVELOPER RICHMOND AMERICAN HOMES 5171 CALIFORNIA AVE, STE 120 IRVINE, CA PHONE: (949)467-2600 CIVIL ENGINEER HUNSAKER & ASSOCIATES 3 HUGHES IRVINE, CA 92618 PHONE: (949) 458-5402 FAX: (949) 465-1102 ARCHITECT WILLIAM HEZMALHALCH ARCHITECTS, INC. 2850 REDHILL AVE, STE 200 SANTA ANA, CA, 92705 PHONE: (949) 250-0607 ext 8740 FAX: (949) 250-1529 MONROE STREET AVENUE 58VIDA BELLA DRIVECANTATA DRIVE RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMPO These plans have been reviewed by the Coachella Valley Water District in accordance with Water Code Title 7, Division 1, Chapter 3, Article 10.8, Section 65597 et seq. requiring efficient landscape and irrigation design in cooperation with the local governing agency (City or County). "Approval of this drawing by CVWD staff does not constitute approval to encroach into district and USBR Rights-of-Way. Trees, plants, walls, and permanent structure of any kind may not be planted or installed in CVWD and USBR easements or right-of-way without first obtaining an encroachment permit from CVWD. CVWD PLAN # DATE DEVELOPMENT SERVICE DEPARTMENT WATER MANAGEMENT DEPARTMENT D I S T R I C T W A T E R CL-1, IR-1, PT-1, PS-1 CL-2, IR-2, PT-2, PS-2 BY:DATE: THIS PROJECT COMPLIES WITH APPLICABLE ASPECTS OF THE STATE WATER EFFICIENCY LANDSCAPE ORDINANCE AB 1881. PLANTING AND IRRIGATION DESIGN FEATURES ARE IN ACCORDANCE WITH THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN. PATRICK C. M. MURPHY, LANDSCAPE ARCHITECT, CA 1881 DATED:PLAN SETSMP PLAN CONTROL02/08/2022'C' PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE LOT 95PLAN: S852-ALPENDLETON/ SPANISHSALES OFFICESIDEYARDMULCH123456711'-2"80'3'1'EQ. 6'6' 7'-6"20'TYP.5'5'11'-6"11'-3"20'11'1'-5"18"18"3'-8"3'-6" 14" 2'1'-10"3'-9"4'30"7'-11" CL 3'28'-6"4'6" TYP. 2' TYP. 8'9'-6"5'MULCH ONLY3'-6"4'-6"4'-6"3'-6"7'10'10'3'24'-6"4'4'30°40'-4"23'-5"7'-3" 5 ' - 5 " F.O.B. 1 4 ' 5 ' 1 4 ' 4 ' 2 ' - 4 " 2 ' 7'-6"4'-8"4'6'-11"6'5'2'22'6'-3"1 0 ' 1 0 '2'2 '4'1'-4"4'2 0 ' - 6 "2'4'20'3 0 "SQ . TYP . 1 0 ' 1 0 ' 1 0 '4'11'-8"2'2 '4'5 0 '7'-4"9'-3"2'7'12'-6" 8'30'-8"12"18" 22"2'18"18"8'7 ' 7 ' - 6 " 7 ' 1 3 ' - 6 " 6 ' - 6 " 6 ' 1 9 ' - 4 "6"11'-6"6"TYP.6 ' 5 ' - 6 " 1 1 ' - 6 " 9 ' 7 ' - 9 " 1 4 ' 4 ' - 5 " 2 0 ' - 6 "4'4'8'TYP.` 3 ' - 6 " 2 6 ' - 1 0 " 3 ' - 8 " 5 ' - 6 " 6 "S-23S-24S-11S-14S-7S-25S-5S-21S-6S-18S-5S-22S-3S-266" 12"S-828'-8"A-4A-1A-3A-2A-6A-5A-7A-5S-1S-9S-9S-9S-2S-9S-5S-21S-22S-8S-4S-4S-20B-5B-3B-6B-7S-9B-4S-4S-19PAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPATURFTURFTURFTURFTURFS-13S-94'12'-8"2'DANA POINT CA 9262934197 COAST HWY SUITE 200(949) 443-1446SUMMERS/MURPHY & PARTNERS, INC.E N V I R O N M E N T A L D E S I G NNOTE:- "ALL IMPROVEMENTS TO BEMAINTAINED BY DEVELOPER UNTILMAINTENANCE RESPONSIBILITY ISTURNED OVER TO INDIVIDUALHOMEOWNER OR THE MASTERASSOCIATION"- SOILS REPORT TO BE PROVIDEDBY OWNER010 20 30 40SCALE: 1" = 10' - 0"NORTHSMPSMPSMPCONSTRUCTIONLAYOUT177-CLCL-12PLAN 852-AL | LOT 95 - 'PENDLETON' DETAIL/SHEETA-1CONCRETE PAVINGA CD-2COLOR: T.B.S.FINISH: T.B.S.JOINT TYPE: T.B.S.A-2CONCRETE STEPPERS W/ LOOSE PEBBLE JOINTD CD-3COLOR: T.B.S.FINISH: T.B.S.JONIT TYPE: T.B.S.PEBBLE: T.B.S.A-3FIRE TABLEITEM: T.B.S. AVAIL. FROM:A-4BARBECUE COUNTERA CD-4COUNTER TOP: T.B.S.VENEER: T.B.S.GRILL UNIT: T.B.S.ACCESS DOOR: T.B.S.A-5LOOSE GRAVELE CD-2GRAVEL: T.B.S.A-6RAISED WOOD PLANTER BEDC CD-2COLOR: T.B.S.A-7TURF/GRAVEL CHECKER BOARD, 30"SQ. W/ METAL EDGING E CD-2GRAVEL: TO MATCH ITEM A-5TURF: TO MATCH ITEM A-8EDGING: TO MATCH ITEM S-9NO.DESCRIPTION DETAIL/SHEETVERIFY FINAL SELECTIONS WITH LANDSCAPE ARCHITECT.SAMPLES OF ALL STONE& TILES MATERIALS ARE TO BE DELIVERED ON-SITEPRIOR TO PLACING ORDER FOR FINAL APPROVAL BY LANDSCAPE ARCHITECT & OWNER.SITES-1AC UNIT LOCATIONREFER TO ARCHITECT'S PLANSS-2UTILITY LOCATIONSREFER TO ENGINEER'S PLANSS-3TEMPORARY TRAP FENCE & MAINTENANCE GATESD CD-1STEEL COLOR: T.B.S.S-4PRODUCTION WALL / FENCEREFER TO PRODUCTION WALL & FENCE PLANS BY OTHERSS-5PRODUCTION SIDE YARD GATE & RETURN WALLREFER TO PRODUCTION WALL & FENCE PLANS BY OTHERSS-6TRUNCATED DOMESREFER TO ENGINEER'S PLANSS-7TEMPORARY VINYL SCREEN FENCE AT RESTROOMA CD-1COLOR: T.B.S.S-8TEMPORARY CONCRETE WALKA CD-2COLOR: T.B.S.FINISH: T.B.S.JOINT TYPE: T.B.S.S-9METAL EDGINGF CD-2COLOR: T.B.S.S-10TEMPORARY AC PAVING PARKINGREFER TO ENGINEER'S PLANSS-11HANDICAPPED PARKING STALL AND LOADING ZONEREFER TO ENGINEER'S PLANSS-12CONCRETE WHEEL STOP, TYP.REFER TO ENGINEER'S PLANSS-13TEMPORARY CONCRETE STEPSE CD-3COLOR: T.B.S.FINISH: T.B.S.S-14A.D.A. ACCESSIBLE RESTROOMBY OWNERS-15CONCRETE STEPPERSD CD-3COLOR: T.B.S.FINISH: T.B.S.S-16DECOMPOSED GRANITEE CD-2D.G.: T.B.S.S-17LARGE GLOBE SCULPTURE W/ MIRROR REFLECTIVE SURFACE BASEITEM: T.B.S.S-18A.D.A. PARKING SIGNREFER TO ENGINEER'S PLANSS-19WOOD MULCH ONLY SIDE YARDS-20OUTDOOR FURNITUREBY OTHERSS-21SIDEYARD CONCRETE STOOPREFER TO ARCHITECT'S PLANSS-22PRECAST CONCRETE STEPPER, 24"SQ.COLOR: NATURAL GRAYS-23PROJECT ID SIGN LOCATIONBY OWNERS-24PROJECT FLAG POLE LOCATIONBY OWNERS-25TEMPORARY CONSTRUCTION SCREEN FENCEC CD-1COLOR: T.B.S.S-26TEMPORARY STEEL HANDRAILF CD-3COLOR: T.B.S.FINISH SCHEDULE1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ADJUST ASNECESSARY WHILE MAINTAINING THE DESIGN CONCEPT.2. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING ANYWORK AND CONTACT LANDSCAPE ARCHITECT FOR AUTHORIZATION IFMODIFICATIONS ARE NECESSARY.3. PAVING CONTRACTOR SHALL COORDINATE WITH DRAINAGE CONTRACTOR,IRRIGATION CONTRACTOR AND ELECTRICIAN TO ENSURE THAT ALL SLEEVES ANDCROSSINGS ARE PROVIDED PRIOR TO PLACING OF PAVING, CONCRETE, ETC.4. VERIFY WITH THE PROJECT SOILS ENGINEER THE NEED FOR REINFORCING, BASEMATERIALS, PRESATURATION, ETC., FOR WALKS, PATIOS, FOOTINGS, ETC.5. EXPANSION JOINTS OCCUR AT BOTTOM OF STEPS, CHANGE IN DIRECTION OFCONCRETE WALKS, ADJACENT TO BUILDINGS AND WHERE NEW CONCRETE PAVINGABUTS EXISTING SIDEWALKS AND/OR CURBS. THE RECOMMENDED SPACING FOREXPANSION JOINTS IN WALKS IS 16'-0" O.C. FOR CONTINUOUS WALKS UNLESSOTHERWISE RECOMMENDED BY SOILS ENGINEER.6. SCORE JOINTS OCCUR WHERE SHOWN ON PLAN AND AS NECESSARY TO MINIMIZEAND CONTROL CRACKING OF CONCRETE PAVING.7. ALL CONSTRUCTION SHALL CONFORM TO ALL LOCAL CODES AND ORDINANCES.8. ALL PRODUCTION WALKS, STOOPS AND DRIVEWAYS ARE TO RECEIVE A MEDIUMBROOM FINISH UNLESS OTHERWISE NOTED.9. FINISH SURFACE OF CONCRETE TO BE 1/2" MINIMUM BELOW STUCCO SCREED;VERIFY IN FIELD AND ADJUST GRADES IF NECESSARY TO ACHIEVE THIS.10. STEP TREADS TO BE 12" WIDE (TYPICAL). STEPS GROUPED TWO OR MORETOGETHER ARE TO RECEIVE HANDRAILS.11. ALL HORIZONTAL CONTROL FOR WALLS OR FENCES BY OTHERS. REFER TO CIVILENGINEER'S PLANS.12. SLEEVE ALL UNDERGROUND WIRE FOR LOW VOLTAGE LIGHTING/MASTER SLEEVINGPLAN BY SMP.13. FOR GRADING AND DRAINAGE INFORMATION REFER TO CIVIL ENGINEER'S PLANS.CONSTRUCTION NOTES:SYMBOL LEGENDFOBPALCEJPLSYMBOL DESCRIPTION SYMBOL DESCRIPTION PLANTING AREA ALIGN FACE OF BUILDING CALL OUT EXPANSION JOINT CENTER LINE ELECTRIC SERVICE BOX STREET LIGHT PROPOSED STEP LOCATION TRANSFORMER SLAB BOX PROPERTY LINETYP. TYPICALEARTH MOUNDING A.D.A PATH OF TRAVELUSE EASEMENT AREA--MATCHLINE: SEE SHEET CL-2FINISH SCHEDULE (CONT'D)NO.DESCRIPTION DETAIL/SHEETN.T.S.KEYMAPRESIDENZA COURTPASATIEMPO COURTIL SERENATA DRIVE ARPEGGIO DRIVEFIORI DEL DESERTO DRIVE VIA PASATIEMPCL-1 PLANNING APPROVALADMINISTRATIVE CASE # ____________________EXHIBIT # ____________________ INITIAL : DATE :MUP2021-002303/03/22SFE LOT 97PLAN: S850-CLPOMONA/CONTEMPORARYPRAIRIELOT 96PLAN: S853-BLPINECREST/MONTEREYLOT 95PLAN: S852-ALPENDLETON/ SPANISHSALES OFFICEML SLMSMSLSIDEYARDMULCHEQ.6'6'7'-6"3'-9"4'30"7'-11" MULCH ONLY MULCH ONLY 5'-5"14'5'14'4'-8"4'6'-11"1'-4"4'20'-6"2'4'20'30"SQ.TYP.4'2'50' 7'12'-6"30° 6'-10" 8'30'-8"12"18" 22"2'18"18"8'30°60°16'7 ' 7 ' - 6 " 7'13'-6"6'-6"6'3'-6"1 9 ' - 4 "6"11'-6"6"TYP.6'5'-6"11'-6" 9 ' 7 ' - 9 " 14'4'-5"20'-6"4'4'8'TYP.`3'-6"26'-10"3'-8"5'-6" 6 " 6 " 8 ' 6 ' - 5 "3'-6"3'-3"TYP.1 9 ' 5 ' - 1 0 "5'-10"8'-6"5'11'-2" 9'-8"4'5'8'-8"10'2'-8"30"18"22"30"16"3'3'2'-9" 4'-4" 18" 3'2'3'2'3'2'2'2'15'R6' CL 6'-6" 21"21"31'-6"12"TYP.3'-6"SQ.TYP.R 6 ' 21"21" 5'-6"3'-6"19'-3"16'-9"30"15'-2"19'-9"6'30"8'23'R20'4'14"TYP.15'-10"3'-3"R1 1 ' 12" 21" 4'-6" 4'-9"30"30"4'-4"3'-4"30"30" 12'6'10'6'-9"6'-9" 6"TO12" 21'-3"4'-6" 16" 16'4'R12'19'-4"6'3'-6"S-56"12"S-828'-8"S-3A-6A-5A-7S-1S-9S-9S-9S-5S-21S-1S-5S-22S-8S-2S-8S-9S-5S-21S-5S-22S-4S-4S-1S-9S-5S-17S-15S-16S-9S-20B-5B-3B-6B-7B-9B-8S-9B-4C-9C-5S-20C-8C-4C-4C-3C-7C-10C-8S-20C-14C-3C-13C-3C-11C-12S-21S-4S-4S-19B-2C-2C-1BC-1AC-5C-6±3'-9"±3'-6"±4'-3"±3'C-3C-1AC-1BC-1APAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPATURFTURFTURFTURFTURFTURFTURF4'12'-8"16'10'-9" 5'2'13'-6"9'-3"7'5'-3"1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ADJUST ASNECESSARY WHILE MAINTAINING THE DESIGN CONCEPT.2. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO BEGINNING ANYWORK AND CONTACT LANDSCAPE ARCHITECT FOR AUTHORIZATION IFMODIFICATIONS ARE NECESSARY.3. PAVING CONTRACTOR SHALL COORDINATE WITH DRAINAGE CONTRACTOR,IRRIGATION CONTRACTOR AND ELECTRICIAN TO ENSURE THAT ALL SLEEVES ANDCROSSINGS ARE PROVIDED PRIOR TO PLACING OF PAVING, CONCRETE, ETC.4. VERIFY WITH THE PROJECT SOILS ENGINEER THE NEED FOR REINFORCING, BASEMATERIALS, PRESATURATION, ETC., FOR WALKS, PATIOS, FOOTINGS, ETC.5. EXPANSION JOINTS OCCUR AT BOTTOM OF STEPS, CHANGE IN DIRECTION OFCONCRETE WALKS, ADJACENT TO BUILDINGS AND WHERE NEW CONCRETE PAVINGABUTS EXISTING SIDEWALKS AND/OR CURBS. THE RECOMMENDED SPACING FOREXPANSION JOINTS IN WALKS IS 16'-0" O.C. FOR CONTINUOUS WALKS UNLESSOTHERWISE RECOMMENDED BY SOILS ENGINEER.6. SCORE JOINTS OCCUR WHERE SHOWN ON PLAN AND AS NECESSARY TO MINIMIZEAND CONTROL CRACKING OF CONCRETE PAVING.7. ALL CONSTRUCTION SHALL CONFORM TO ALL LOCAL CODES AND ORDINANCES.8. ALL PRODUCTION WALKS, STOOPS AND DRIVEWAYS ARE TO RECEIVE A MEDIUMBROOM FINISH UNLESS OTHERWISE NOTED.9. FINISH SURFACE OF CONCRETE TO BE 1/2" MINIMUM BELOW STUCCO SCREED;VERIFY IN FIELD AND ADJUST GRADES IF NECESSARY TO ACHIEVE THIS.10. STEP TREADS TO BE 12" WIDE (TYPICAL). STEPS GROUPED TWO OR MORETOGETHER ARE TO RECEIVE HANDRAILS.11. ALL HORIZONTAL CONTROL FOR WALLS OR FENCES BY OTHERS. REFER TO CIVILENGINEER'S PLANS.12. SLEEVE ALL UNDERGROUND WIRE FOR LOW VOLTAGE LIGHTING/MASTER SLEEVINGPLAN BY SMP.13. FOR GRADING AND DRAINAGE INFORMATION REFER TO CIVIL ENGINEER'S PLANS.CONSTRUCTION NOTES:SYMBOL LEGENDFOBPALCEJPLSYMBOL DESCRIPTION SYMBOL DESCRIPTION PLANTING AREA ALIGN FACE OF BUILDING CALL OUT EXPANSION JOINT CENTER LINE ELECTRIC SERVICE BOX STREET LIGHT PROPOSED STEP LOCATION TRANSFORMER SLAB BOX PROPERTY LINETYP. TYPICALEARTH MOUNDING A.D.A PATH OF TRAVELUSE EASEMENT AREA--DANA POINT CA 9262934197 COAST HWY SUITE 200(949) 443-1446SUMMERS/MURPHY & PARTNERS, INC.E N V I R O N M E N T A L D E S I G NNOTE:- "ALL IMPROVEMENTS TO BEMAINTAINED BY DEVELOPER UNTILMAINTENANCE RESPONSIBILITY ISTURNED OVER TO INDIVIDUALHOMEOWNER OR THE MASTERASSOCIATION"- SOILS REPORT TO BE PROVIDEDBY OWNER010 20 30 40SCALE: 1" = 10' - 0"NORTHSMPSMPSMPCONSTRUCTIONLAYOUT177-CLCL-23PLAN S853-BL | LOT 96 - 'PINECREST' DETAIL/SHEETB-1CONCRETE DRIVEWAYA CD-2COLOR: T.B.S.FINISH: T.B.S.JOINT TYPE: T.B.S.B-2CONCRETE PATIO PAVINGA CD-2COLOR: T.B.S.FINISH: T.B.S.JOINT TYPE: T.B.S.B-3CONCRETE STEPPERS W/ DECOMPOSED GRANITE JOINTD CD-3CONC. COLOR: T.B.S.CONC. FINISH: T.B.S.D.G.: TO MATCH ITEM B-4B-4DECOMPOSED GRANITEE CD-2D.G.: T.B.S.B-5WOOD LODGE POLE VINE SUPPORTB CD-1COLOR: T.B.S.B-6FIRE RINGITEM: T.B.S. AVAIL. FROM:ALLOW 6-8 WEEKS LEAD TIME FOR MATERIAL DELIVERYB-7WATER FEATUREC CD-4URN: T.B.S.PEBBLE: T.B.S.ALLOW 6-8 WEEKS LEAD TIME FOR MATERIAL DELIVERYB-8BBQ COUNTERA CD-4COUNTER TOP: T.B.S.VENEER: T.B.S.GRILL UNIT: T.B.S.ACCESS DOORS:B-9PLAY HOUSEBY OWNERALLOW 6-8 WEEKS LEAD TIME FOR MATERIAL DELIVERYNO.DESCRIPTION DETAIL/SHEETVERIFY FINAL SELECTIONS WITH LANDSCAPE ARCHITECT.SAMPLES OF ALL STONE& TILES MATERIALS ARE TO BE DELIVERED ON-SITEPRIOR TO PLACING ORDER FOR FINAL APPROVAL BY LANDSCAPE ARCHITECT & OWNER.SITES-1AC UNIT LOCATIONREFER TO ARCHITECT'S PLANSS-2UTILITY LOCATIONSREFER TO ENGINEER'S PLANSS-3TEMPORARY TRAP FENCE & MAINTENANCE GATESD CD-1STEEL COLOR: T.B.S.S-4PRODUCTION WALL / FENCEREFER TO PRODUCTION WALL & FENCE PLANS BY OTHERSS-5PRODUCTION SIDE YARD GATE & RETURN WALLREFER TO PRODUCTION WALL & FENCE PLANS BY OTHERSS-6TRUNCATED DOMESREFER TO ENGINEER'S PLANSS-7TEMPORARY VINYL SCREEN FENCE AT RESTROOMA CD-1COLOR: T.B.S.S-8TEMPORARY CONCRETE WALKA CD-2COLOR: T.B.S.FINISH: T.B.S.JOINT TYPE: T.B.S.S-9METAL EDGINGF CD-2COLOR: T.B.S.S-10TEMPORARY AC PAVING PARKINGREFER TO ENGINEER'S PLANSS-11HANDICAPPED PARKING STALL AND LOADING ZONEREFER TO ENGINEER'S PLANSS-12CONCRETE WHEEL STOP, TYP.REFER TO ENGINEER'S PLANSS-13TEMPORARY CONCRETE STEPSE CD-3COLOR: T.B.S.FINISH: T.B.S.S-14A.D.A. ACCESSIBLE RESTROOMBY OWNERS-15CONCRETE STEPPERSD CD-3COLOR: T.B.S.FINISH: T.B.S.S-16DECOMPOSED GRANITEE CD-2D.G.: T.B.S.S-17LARGE GLOBE SCULPTURE W/ MIRROR REFLECTIVE SURFACE BASEITEM: T.B.S.S-18A.D.A. PARKING SIGNREFER TO ENGINEER'S PLANSS-19WOOD MULCH ONLY SIDE YARDS-20OUTDOOR FURNITUREBY OTHERSS-21SIDEYARD CONCRETE STOOPREFER TO ARCHITECT'S PLANSS-22PRECAST CONCRETE STEPPER, 24"SQ.COLOR: NATURAL GRAYS-23PROJECT ID SIGN LOCATIONBY OWNERS-24PROJECT FLAG POLE LOCATIONBY OWNERS-25TEMPORARY CONSTRUCTION SCREEN FENCEC CD-1COLOR: T.B.S.S-26TEMPORARY STEEL HANDRAILF CD-3COLOR: T.B.S.FINISH SCHEDULEPLAN S850-CL | LOT 97 - 'POMONA' DETAIL/SHEETC-1A&B FRONT YARD CONCRETE PAVINGA CD-2C-1A: COLOR: T.B.S, FINISH: T.B.SC-1B: COLOR: T.B.S, FINISH: T.B.SC-2DECORATIVE POTSITEM: T.B.S. AVAIL. FROM:ALLOW 6-8 WEEKS LEAD TIME FOR MATERIAL DELIVERYC-3REAR YARD CONCRETE PAVINGA CD-2COLOR: T.B.S.FINISH: T.B.S.JOINT TYPE: T.B.S.C-4CONCRETE BANDINGD CD-2COLOR, FINISH: TO MATCH ADJACENT CONCRETE PAVING (ITEM C-3)C-5GROUTED FLAGSTONE PAVINGA CD-3STONE: T.B.S.GROUT: T.B.S.C-6DECOMPOSED GRANITEE CD-2D.G.: T.B.S.C-7FLAGSTONE STEPPERS ON D.G.B CD-3STONE: TO MATCH ADJACENT FLAGSTONE (ITEM C-5)D.G.: TO MATCH ADJACENT D.G. (ITEM C-6)C-8NATURAL STONE BOUDLERSB CD-2SIZE: "L"- 4' DIA., "M"- 3' DIA., "S"- 2' DIA.ITEM: T.B.S. AVAIL. FROM:C-9ROLLOUT BARBECUEITEM: T.B.S.C-10STONE FIREPITE CD-1STONE: T.B.S.GROUT: T.B.SC-11BOCCE BALL COURTF CD-1PLAY SURFACE: T.B.S.FRAME CONCRETE: TO MATCH ADJACENT PAVING (ITEM C-3)C-12WOOD BENCHITEM: T.B.S. AVAIL. FROM:ALLOW 6-8 WEEKS LEAD TIME FOR MATERIAL DELIVERYC-13CONCRETE STEPPERS W/ TURF JOINTC CD-3CONCRETE: TO MATCH ADJACENT PAVING (ITEM C-3)MATCHLINE: SEE SHEET CL-1RESIDENZA COURTPASATIEMPO COURTIL SERENATA DRIVE ARPEGGIO DRIVEFIORI DEL DESERTO DRIVE VIA PASATIEMPN.T.S.KEYMAPCL-2 PLANNING APPROVALADMINISTRATIVE CASE # ____________________EXHIBIT # ____________________ INITIAL : DATE :MUP2021-002303/03/22SFE DANA POINT CA 9262934197 COAST HWY SUITE 200(949) 443-1446SUMMERS/MURPHY & PARTNERS, INC.E N V I R O N M E N T A L D E S I G NNOTE:- "ALL IMPROVEMENTS TO BEMAINTAINED BY DEVELOPER UNTILMAINTENANCE RESPONSIBILITY ISTURNED OVER TO INDIVIDUALHOMEOWNER OR THE MASTERASSOCIATION"- SOILS REPORT TO BE PROVIDEDBY OWNERSMPSMPSMPCONSTRUCTIONDETAILS177-CDCD-14SCALE: 1" = 1'-0"SECTION VIEWLEGENDREFER TO LAYOUT PLAN FOR SPACING18"20" 42"18" 3"8" DIA.1324651. 4" DIA. LODGE POLE POSTS W/ CHAMFERTOP, PRESSURE TREATED2. GUY WIRE (STANDARD 18" DIA. MIN.)3. TURNBUCKLES OR SIMILAR TO ASSURETAUGHT WIRE (1 PER RUN)4. D.G. FINISH SURFACE5. CONCRETE FOOTING6. COMPACTED SUBGRADE7.14x6" EYE BOLTNOTES:·ALL LUMBER TO BE SAW SIZED DOUGLAS FIR.·ALL CONNECTORS, FASTENERS AND OTHER HARDWARE TO BE HOT DIPPED GALVANIZED.·PAINT OR STAIN WOOD PER FINISH SCHEDULE (IF PAINTING, TREAT ALL EXPOSEDSURFACES WITH (2) TWO COATS MOISTURE-PROOF PRIMER AND (2) TWO FINISH COATS -REFER TO FINISH SCHEDULE FOR COLOR.79"3"6" O.C. TYP3' 2'-9"3"4'-0"4'-0"6" O.C. TYP.3' 2'-9"3"8'NOTESLEGENDDOUBLE GATES ELEVATIONSCALE: 1/2" = 1'-0"FENCE ELEVATIONSCALE: 1/2" = 1'-0"FOOTING AT CONCRETESCALE: 1" = 1'-0"FENCE SECTION- FENCE DESIGN TO MATCH ADJACENT TRAP FENCE DESIGN- ALL SURFACES SHALL BE GROUND SMOOTH- TREAT ALL EXPOSED SURFACES W/(2) TWO COATS MOISTURE-PROOFPRIMER AND (2) COATS ENAMEL (COLOR BY OWNER)- OWNER OPTION TO HAVE GATE POWDER-COATED. (COLOR PER OWNER)- ALL CONNECTORS, FASTENERS AND OTHER HARDWARE TO BE HOTDIPPED GALVANIZEDSCALE: 1" = 1'-0"SEE ENLARGEMENT1. FINISH GRADE2. IRON FINIAL BALL3. 1-1/2" SQ. TUBULAR STEEL POST AT 8'-0" O.C. W/ CAP4. 1" DIA. TUBULAR STEEL TOP AND BOTTOM RAIL5. 1/2" DIA. TUBULAR STEEL PICKET @ 4" MAX O.C.6. ADJACENT CONCRETE OR ASPHALT PAVING7. LOCKABLE GATE LATCH8. 1" X 1-1/2" TUBULAR STEEL GATE FRAME (VERTICAL ONLY)9. (3) HEAVY DUTY HINGES SELF- CLOSING AND SELF-LATCHING10. CONCRETE FOOTING11. METAL 'L' BRACKET - BOLT THROUGH POST WITH (2) BOLTS, MOUNTTO CONCRETE WITH (2) BOLTS AND POR-ROK OR APPROVED EQUAL.SET PERPENDICULAR TO FENCE.12. DECORATIVE COVER PLATE OVER BRACKET. 2'-9" 3' 3"3111272351102453415245936754442"13138131. 2'-0" HIGH VINYL LATTICE PANEL2. 2X7 TOP & BOTTOM RAIL3. 5X5 VINYL POST4. 3"~6" TONGUE & GROOVELEGEND6'2'2'SECTION / ELEVATION VIEWSCALE: 1/2" = 1'-0"SECTION VIEWSCALE: 1/2" = 1'-0"1234655. FINISH GRADE6. 8X24 DOMED CONCRETE FOOTING - REFER TO STRUCTURAL ENGINEER'S DRAWINGSAVAILABLE THROUGH FENCWORKS INC.1-800-350-56201. DOMED CAP2. 2X7 TOP & BOTTOM RAIL3. 5X5 POST4. 6" TONGUE & GROOVE5. FINISH GRADE6. 8X24 DOMED CONCRETE FOOTING- REFER TOSTRUCTURAL ENGINEER'S DRAWINGSLEGEND8'-0"6'-0" 4'-7" 7" 2'-0"SECTION / ELEVATION VIEWSCALE: 1/2" = 1'-0"SECTION VIEWSCALE: 1/2" = 1'-0"123465TRAP FENCEDWIRE VINE SUPPORTBVINYL SCREEN FENCE AT RESTROOMACONSTRUCTION VINYL SCREEN FENCEC6"6"25646"REFER TO PLAN12"718371LEGEND1. 6" X 12" CONCRETE CURB2. 1 1/4" CLAY OR OYSTER SHELL3. 3" COMPACTED D.G.4. FINISH GRADE, ADJACENT ARTIFICIAL TURF5. 5" THICK COMPACT AGGREGATE BASE6. NATIVE SOIL7. 1" X 2" OR 2" X 4" TREX BUMPER8. RED HEAD W/ COUNTER SINK BOLT AT TREXBUMPERSCALE: 1" = 1'-0"SECTION VIEWBOCCE BALL COURTFFIRE PITELEGENDSECTION VIEWSCALE: 3/4" = 1'-0"1. STONE COBBLE W/ GROUT - REFER TO FINISHSCHEDULE2. CMU BLOCK CONSTRUCTION3. LAVA ROCK4. CONCRETE PAVING5. COMPACTED SUBGRADE6. ADJACENT STONE PAVING / D.G.7. FIRE LOG12"4'-6"DIA.12"12"6214573NOTE:·REFER TO SOILS ENGINEER'S REPORT FOR MINIMUMTHICKNESS OF CONCRETE, REINFORCING STEEL,COMPACTED SUBGRADE, AND SUB-BASE MATERIAL. PLANNING APPROVALADMINISTRATIVE CASE # ____________________EXHIBIT # ____________________ INITIAL : DATE :MUP2021-002303/03/22SFE DANA POINT CA 9262934197 COAST HWY SUITE 200(949) 443-1446SUMMERS/MURPHY & PARTNERS, INC.E N V I R O N M E N T A L D E S I G NNOTE:- "ALL IMPROVEMENTS TO BEMAINTAINED BY DEVELOPER UNTILMAINTENANCE RESPONSIBILITY ISTURNED OVER TO INDIVIDUALHOMEOWNER OR THE MASTERASSOCIATION"- SOILS REPORT TO BE PROVIDEDBY OWNERSMPSMPSMPCONSTRUCTIONDETAILS177-CDCD-25NOTED IN PLAN OR 6"TYP.123R 12 "6" MIN. 1" - PLANTING AREA 2" - TURF AREA 1. FINISH GRADE2. CONCRETE MOW STRIP3. COMPACTED SUBGRADESCALE: 3" = 1'-0"SECTION VIEWLEGENDNOTE:·REFER TO SOILS ENGINEER'SREPORT FOR MINIMUM THICKNESSOF CONCRETE, REINFORCINGSTEEL, COMPACTED SUBGRADE,AND SUB-BASE MATERIAL.SECTION VIEWSCALE: 1" = 1'-0"6. REINFORCING STEEL - REFER TOSOILS REPORT FORREQUIREMENTS7. AGGREGATE SUB-BASE - REFER TOSOILS REPORT FOR DEPTHREQUIREMENTS8. FINISH GRADE9. COMPACTED SUBGRADE - REFERTO SOILS REPORT FORREQUIREMENTS10. 1" MINIMUM, 2" AT TURF AREAS1. POLYSTYRENE JOINT CAP OVEREXPANSION BOARD. REMOVE TOP OFJOINT CAP PRIOR TO CAULKING. (SEENOTE)2. 3/8" WIDE FULL DEPTH ASPHALTSATURATED FIBER EXPANSION BOARD3. CONCRETE - REFER TO SOILS REPORTFOR THICKNESS4. 1/4" RADIUS - ALL EDGES5. SAWCUT JOINTLEGENDSECTION VIEWSCALE: 1" = 1'-0"EXPANSION JOINTSCORE JOINT3679412841035679NOTE:- APPLY 12" DEEP JOINT SEALANT(CAULKING) INTO GROOVE . SAND INWITH #60 SILICA SAND. MATCHCOLOR OF PAVINGCONCRETE BANDINGDCONCRETE PAVINGALOOSE PEBBLE OR DECOMPOSED GRANITEE1231/3 BURIED 2/3 BURIED LEGEND1. LANDSCAPE BOULDER- REFER TO BOULDER LEGENDON LC SHEET SERIES.2. FINISH GRADE.3. COMPACTED SUB-GRADE.SECTION VIEWSCALE: 3/4" = 1'-0"LEGEND1. FINISH GRADE - PLANTING AREA2. FINISH GRADE - TURF AREA3. COMPACTED SUBGRADE4. METAL - REFER TO FINISH SCHEDULE5. LOOSE PEBBLES - REFER TO FINISH SCHEDULE2432"1"SECTION VIEWSCALE: 1-1/2" = 1'-0"15432"1SECTION VIEWSCALE: 1-1/2" = 1'-0"LEGEND1. FINISH GRADE PLANTING AREA2. DECOMPOSED GRANITE /DECORATIVE GRAVEL FIELD 3"DEEP - REFER TO FINISHSCHEDULE FOR SIZE AND COLOR3. COMPACTED SUBGRADE - REFERTO SOILS REPORT4. FILTER FABRIC124633"55. METAL HEADER - ATTACHMENTPER MANUFACTURER6. METAL STAKE 12" x 2" x 12"@ 4'-0" O.C.D.G. PAVINGPLANTING AREA312426SCALE: 1" = 1'-0"SECTION/ELEVATION VIEWSCALE: 1" = 1'-0"PLAN VIEW18" MIN.LEGEND1. 4x4 WOOD POST, PRESSURE TREATED2. 2x8 REDWOOD BOARD3. ADJACENT D.G. PAVING4. RAISED PLANTER FINISH GRADE5. COMPACTED SUBGRADE6. FILTER FABRIC7. DRAINAGE / IRRIGATION8. 2x8 WOOD CAP 18"5NOTES:·ALL LUMBER TO BE SAW SIZED DOUGLAS FIR.·ALL CONNECTORS, FASTENERS AND OTHERHARDWARD TO BE HOT DIPPED GALVANIZED.·PAINT OR STAIN WOOD PER FINISH SCHEDULE(IF PAINTING, TREAT ALL EXPOSED SURFACESWITH (2) TWO COATS MOISTURE-PROOFPRIMER AND (2) TWO FINISH COATS - REFERTO FINISH SCHEDULE FOR COLOR.76178NATURAL STONE BOULDERBRAISED WOOD PLANTERCMETAL EDGINGF PLANNING APPROVALADMINISTRATIVE CASE # ____________________EXHIBIT # ____________________ INITIAL : DATE :MUP2021-002303/03/22SFE SCALE: 1" = 1'-0"SECTION VIEWPLANSCALE: N. T. S.3/4"MAX.NOTE:·REFER TO SOILS ENGINEER'SREPORT FOR MINIMUM THICKNESSOF CONCRETE, REINFORCINGSTEEL, COMPACTED SUBGRADE,AND SUB-BASE MATERIAL.123455267LEGEND1. FINISH GRADE2. PAVING MATERIAL - REFER TO FINISH SCHEDULE3. 4" MIN. CONCRETE SUB-POUR - REFER TO SOILSREPORT4. STEEL REINFORCING - REFER TO SOILS REPORT5. GROUT - REFER TO FINISH SCHEDULE6. SUB-BASE MATERIAL - REFER TO SOILS REPORT7. COMPACTED SUBGRADESCALE: N.T.S.PLAN6" MAX.LEGEND1. FINISH GRADE2. STONE PAVING - REFER TO FINISH SCHEDULE3. DECOMPOSED GRANITE - REFER TO FINISHSCHEDULE4. COMPACTED SUBGRADE43214"MIN.32SCALE: 1" = 1'-0"SECTION VIEW1" MIN.REFER TO LAYOUT PLANFOR DIMENSIONSLEGEND23154SCALE: 1" = 1'-0"SECTION VIEW1. FINISH GRADE2. 1/2" RADIUS ALL EDGES3. CONCRETE PAVING - REFER TO FINISH SCHEDULE4. COMPACTED SUBGRADE5. SUB-BASE MATERIALNOTE:·REFER TO SOILS ENGINEER'S REPORT FOR MINIMUM THICKNESS OF CONCRETE, REINFORCINGSTEEL, COMPACTED SUBGRADE, AND SUB-BASE MATERIAL.1" MIN.PER PLAN234156NOTE:- REFER TO SOILS ENGINEER'S REPORT FOR MINIMUMTHICKNESS OF CONCRETE, REINFORCING STEEL SIZE,COMPACTED SUBGRADE, AND SUB-BASE MATERIAL.7SCALE: 1" = 1'-0"SECTION VIEWLEGEND1. FINISH GRADE2.14" RADIUS ALL EDGES3. CONCRETE PAVING - REFER TO FINISH SCHEDULE4. REINFORCING STEEL5. SUB-BASE MATERIAL6. COMPACTED SUBGRADE7. LOOSE PEBBLE / DECOMPOSED GRANITE JOINT -REFER TO FINISH SCHEDULE112"14"112"EQ.EQ.NOTE:·REFER TO SOILS ENGINEER'S REPORT FOR MINIMUM THICKNESS OF CONCRETE,REINFORCING STEEL, COMPACTED SUBGRADE, AND SUB-BASE MATERIAL.6"MIN.1689SCALE: 1" = 1'-0"SECTION VIEWLEGEND1. SLIP RESISTANCE GROOVE2. EXPANSION JOINT, TYP.3. REFER TO GRADING PLAN FORNUMBER OF RISERS4. ADJACENT CONCRETE PAVING5. CONCRETE PAVING - REFER TOFINISH SCHEDULE6. NOSE7. COMPACTED SUBGRADE8. SUB-BASE MATERIAL - REFER TOSOILS REPORT23451"2"14"DEEPNOT TO SCALEINSET112"24"3'12"SCALE: 1" = 1'-0"SECTION VIEWLEGEND53124SCALE: 1" = 1'-0"HANDRAIL FOOTINGSCALE: 1" = 1'-0"HANDRAIL FOOTING1335641.12" x 2" SQ. TUBULAR RAIL2. ADJACENT STEPS - REFER TO CONCRETE STEPS DETAIL3. 1-1/2" SQ. TUBULAR STEEL POST4. CONCRETE FOOTING5. DECORATIVE COVER PLATE OVER BRACKET6. METAL 'L' BRACKET, BOLT THROUGH POST WITH (2) BOLTS, MOUNT TOCONCRETE WITH (2) BOLTS AND SEALED W/ EPOXY OR APPROVED EQUAL29"12"3"9"SQ.SMPSMPSMPCONSTRUCTIONDETAILS177-CDCD-36FLAGSTONE PAVINGACONCRETE STEPPERS W/ TURF JOINTCLOOSE PEBBLE OR DECOMPOSED GRANITEEDANA POINT CA 9262934197 COAST HWY SUITE 200(949) 443-1446SUMMERS/MURPHY & PARTNERS, INC.E N V I R O N M E N T A L D E S I G NNOTE:- "ALL IMPROVEMENTS TO BEMAINTAINED BY DEVELOPER UNTILMAINTENANCE RESPONSIBILITY ISTURNED OVER TO INDIVIDUALHOMEOWNER OR THE MASTERASSOCIATION"- SOILS REPORT TO BE PROVIDEDBY OWNERFLAGSTONE PAVING ON D.G.BCONCRETE STEPPERS W/ LOOSE PEBBLE/D.G. JOINTDHANDRAILF PLANNING APPROVALADMINISTRATIVE CASE # ____________________EXHIBIT # ____________________ INITIAL : DATE :MUP2021-002303/03/22SFE DANA POINT CA 9262934197 COAST HWY SUITE 200(949) 443-1446SUMMERS/MURPHY & PARTNERS, INC.E N V I R O N M E N T A L D E S I G NNOTE:- "ALL IMPROVEMENTS TO BEMAINTAINED BY DEVELOPER UNTILMAINTENANCE RESPONSIBILITY ISTURNED OVER TO INDIVIDUALHOMEOWNER OR THE MASTERASSOCIATION"- SOILS REPORT TO BE PROVIDEDBY OWNERSMPSMPSMPCONSTRUCTIONDETAILS177-CDCD-472"-3" GRAVELPOTTING SOILRESERVOIRPOTTING SOILNOT TO SCALEPOTS TO VARY IN HEIGHTIN-POT RESERVOIR IRRIGATION SYSTEMB1. 2" DEPTH DECORATIVE PEBBLE - REFER TO FINISH SCHEDULE2. PREFAB DISAPPEARING FOUNTAIN BASIN KIT, 3X3, AVAILABLE FROM SOUTHWEST BOULDERAND STONE 760-559-9098 CONTACT: PETER SANCHEZ, REFER TO DETAIL B, THIS SHEET3. FILTER FABRIC ON GRADE4. METAL EDGING5. COMPACT SUBGRADE6. DECORATIVE URN - REFER TO FINISH SCHEDULESCALE: 1" = 1'-0"SECTION VIEWLEGEND613425NOTE:·REFER TO MANUFACTURER'SINSTALLATION MANUAL FORCONSTRUCTION.30"+-2"173423"SECTION VIEWSCALE: 1/2" = 1'-0"PLAN VIEWSCALE: 1/2" = 1'-0"1236"44'3'6NOTE:·REFER TO SOILS ENGINEER'S REPORT FOR MINIMUM THICKNESS OF CONCRETE,REINFORCING STEEL, COMPACTED SUBGRADE, AND SUB-BASE MATERIAL.·REFER TO MANUFACTURER'S INSTALLATION MANUAL FOR CONSTRUCTION.·CONTRACTOR TO VERIFY THAT NATURAL GAS CONNECTION IS AVAILABLE ANDAPPROPRIATELY SIZED FOR EQUIPMENT PRIOR TO ORDERING COMPONENTS.85LEGEND1. ELDORADO OUTDOOR CABINET BASES - REFER TOPARTS LIST AND INSTALLATION INSTRUCTIONS.2. GRILL - REFER TO FINISH SCHEDULE.3. FINISH GRADE4. 3" THICK CAST IN PLACE CONCRETE COUNTERTOPWITH EASED EDGE - REFER TO FINISH SCHEDULE.5. STUCCO FINISH, ALL SIDES - REFER TO FINISHSCHEDULE.6. ADJACENT DECKING7. PROPANE TANK AND SHUT-OFF - CONTRACTOR TOMAKE FINAL HOOK-UP8. CONCRETE FOOTING12"TYP.8'BARBECUE COUNTERACBUBBLING URNC PLANNING APPROVALADMINISTRATIVE CASE # ____________________EXHIBIT # ____________________ INITIAL : DATE :MUP2021-002303/03/22SFE LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE SIDEYARD MULCH 1234567W W 4 5 1 1 1 1 7 7 7 77 8 8 8 8 8 4 6 6 6 5 6 6 1 1 4 44 4 4 4 4 55 5 5 4 5 4 * * * * * * ********************************** * * * * * * * * **** * LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER 0 10 20 30 40 SCALE: 1" = 10' - 0" NORTH SMP SMP SMP IRRIGATION LAYOUT 177-IR IR-1 8 RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMP N.T.S.KEYMAP IR-1MATCH L INE : SEE SHEE T IR - 2 PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE LOT 97 PLAN: S850-CL POMONA/ CONTEMPORARY PRAIRIE LOT 96 PLAN: S853-BL PINECREST/ MONTEREY LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE MLS LMS MSL SIDEYARD MULCH W W 4 7 7 1 1 11 1 1 11 2 2 2 2 2 2 7 7 7 7 8 8 8 8 8 8 5 6 5 4 4 5 5 5 55 4 44 4 4 4 4 55 5 5 * * * * * * * *************** * * * * * * * * **** ****** * * * *********** * ***** LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER 0 10 20 30 40 SCALE: 1" = 10' - 0" NORTH SMP SMP SMP IRRIGATION LAYOUT 177-IR IR-2 9 RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMP N.T.S.KEYMAP IR-2MATCH L INE : SEE SHEE T IR - 1 PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER SMP SMP SMP IRRIGATION LEGEND 177-ID ID-1 10 GPM GPM GPM GPM GPM GPM GPM 5 TO 10 0 TO 5 10 TO 15 15 TO 25 25 TO 35 35 TO 50 50 TO 100 NOTE: 3/4" CL. 200 PVC PIPE 1" CL. 200 PVC PIPE 1-1/2" CL. 200 PVC PIPE 2" CL. 200 PVC PIPE 2-1/2" CL. 200 PVC PIPE 3" CL. 200 PVC PIPE 1-1/4" CL. 200 PVC PIPE PIPE SIZING CHART SIZE EXCEED DESIGNATED GPM RANGE. PIPE SIZING CHART, IN NO INSTANCE SHALL PIPE CONTRACTOR SHALL SIZE ALL LATERAL LINES PER P.O.C. WILKINS NIBCO 11/4" T-580-70 BRONZE BALL VALVE, LINE SIZE, WITH BRONZE WHEEL HANDLE . N/A RAIN BIRD AS APPROVED AS APPROVED AS APPROVED RAIN BIRD 3M AS APPROVED NO SYMBOL NO SYMBOL W ESP-ME OUTDOOR MOUNTED IRRIGATION CONTROLLER INSTALL WEATHER SENSING SYSTEM NO FARTHER FROM CONTROLLER THAN 800' FT FROM CONTROLLER. WIRELESS WEATHER SENSOR TO BE INSTALLED ON EVE WITH SOUTH OR WEST EXPOSURE AND FREE FROM ANY OBSTRUCTIONS SUCH AS TREES, BUILDING, ETC. INSTALL PER MANUFACTURERS SPECIFICATIONS. VALVE TYPE VALVE NUMBER G.P.M. VALVE SIZE (LOW FLOW VALVE RANGE 0.2 - 5.0 GPM) (MED FLOW VALVE RANGE 3.0 - 15.0 GPM) SEE PLAN FOR VALVE SIZE - XACZ-075-PRF ( 3/4" VALVE ) OR XACZ-100-PRF ( 1" VALVE ) PLASTIC TYPE CONTROL VALVE, WITH PRESSURE REGULATOR. INSTALL ON THE DOWNSTREAM SIDE OF EACH DRIP RCV 12" ABOVE FINISH GRADE. INSTALL VALVES AWAY FROM VIEW. RAIN BIRD RAIN BIRD NO SYMBOL MODEL NO. / DESCRIPTIONMANUFACT.SYMBOL IRRIGATION LEGEND RAIN BIRD SUB-SURFACE DRIP TREE BUBBLER EACH SYMBOL REPRESENTS (2) RAIN BIRD 1804-SAM-PRS, 4" POP-UP WITH A 1401 .25 GPM (.5 GPM) FLOOD BUBBLERS PER TREE. XFCV-06-12-XXX DRIPLINE TUBING 0.6 GPH EMITTERS AT 12" ON CENTER SPACING - ALL TUBING SHALL BE INSTALLED ON 2" BELOW GRADE W/ 9" WIRE STAKES FIVE (4) FEET ON CENTER; VERIFY THE LAYOUT AND 16-18" ON CENTER SPACING IN THE FIELD PRIOR TO STARTING WORK. INSTALL DRIP IRRIGATION SYSTEM PER MANUFACTURER'S SPECIFICATIONS. USE RAIN BIRD "XF" FITTINGS FOR CONNECTION BETWEEN PVC LATERAL LINES AND DRIPLINE TUBING. WITH 17MM INSERT FITTINGS, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. MDCFCAP MANUAL FLUSH VALVE. INSTALL FLUSH CAP INSIDE 6" ROUND VALVE BOX, ONE AT THE FAR END OF RAIN BIRD XFD LATERAL. INSTALL MINIMUM OF ONE FLUSH VALVE PER MAXIMUM OF 800' OF TUBING. MULTIPLE FLUSH VALVES MAY BE REQUIRED WITHIN DRIPLINE LAYOUT. ALWAYS INSTALL VALVES IN OPPOSITE DIRECTIONS OF THE PVC/DRIP CONNECTION MANIFOLD. ARV050 AIR/VACUUM RELIEF VALVE INSTALLED WITH COMBINATION TEE AND A 3 4"x 12" REDUCER BUSHING, INSTALL AIR RELIEF ASSEMBLY INSIDE A 6" ROUND VALVE BOX AT THE HIGH POINT OF EACH PLANTER, MIN. 1 ARV PER 500' OF DISTRIBUTION TUBING. USING AIR RELIEF LATERAL, CONNECT AIR RELIEF VALVE TO ALL DRIPLINE LATERALS WITHIN THE ELEVATED AREA (INSTALL (1) MINIMUM OF PER SYSTEM). MULTIPLE ARV'S SHALL BE REQUIRED PER RCV WITHIN UNDULATING AREAS, VERIFY QUANTITY PRIOR TO STARTING WORK, FLUSH VALVES AND AIR RELIEF VALVES SHOWN DIAGRAMMATICALLY, INSTALL VALVE BOX 18" FROM PAVING AND AT HIGH POINTS OF PLANTER AREA. RAIN BIRD RAIN BIRD RAIN BIRD DBY DIRECT BURIAL WATER-PROOF WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) PVC PIPE SCH. 40 AS SLEEVING, TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED PLACE BELOW ALL PAVING, HARDSCAPE, ETC., AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PVC PIPE 1.25" CL. 315 AS MAINLINES 18" BELOW GRADE PVC PIPE 3/4" - 2" SCH. 40 AS LATERAL LINES 12" BELOW GRADE 120 VOLT ELECTRICAL POWER, PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD ESP-SMTe WEATHER SENSING SYSTEM, MOUNT SENSOR TO EAVE OF ROOF IN FULL SUN EXPOSURE. (0.2 - 22.0 GPM) 075-ASVF 3/4" REMOTE CONTROL VALVE. SIZE AS INDICATED 500HLR 1.25" PRESSURE REGULATOR (REQUIRED IF HOUSE PRESSURE EXCEEDS 85PSI) 1" DOMESTIC WATER METER FOR FUTURE RESIDENCE, EXISTING PER CIVIL DRAWINGS. SEE CIVIL PLANS FOR EXACT SIZE AND LOCATION. RAIN BIRD* USE OF HYDROZONES WITH PLANTS GROUPED BASED UPONAMOUNT OF WATER NEEDED TO SUSTAIN THEM. SOIL AMENDMENTS UTILIZED TO IMPROVE WATER HOLDING OF THE LANDSCAPE BASED ON WATERING NEED. AUTOMATIC IRRIGATION SYSTEM ADJUSTED SEASONALLY ANDWITH WATERING HOURS BETWEEN 9:00 P.M. AND 9:00 A.M. IRRIGATION SYSTEM DESIGNED TO WATER DIFFERENT AREAS CAPACITY OF SOIL. IRRIGATION ZONES SEPERATED BY PLANT MATERIAL. Water Conservation Notes: THE FOLLOWING WATER CONSERVATION TECHNIQUES SHALL BE EMPLOYED IN THIS PROJECT: RECOMMENDATIONS GIVEN FOR ANNUAL IRRIGATION SCHEDULE. Prepare and deliver to the City Representative, prior to the start of maintenance, all required and necessary descriptive material in complete detail and sufficient quantity, properly prepared in four individually bound copies. Describe the material installed in sufficient detail to permit qualified operating personnel to understand, operate and maintain all equipment. Each manual shall include the following: i. Index sheet indicating the Contractor's name, address and telephone number, fax number and e-mail address. ii. Duration of guarantee period with guarantee forms. iii. List of equipment with names and addresses of manufacturer's local representatives. iv. Complete operating and maintenance instructions on all major equipment. Operation and Maintenance Manuals: 1) Landscapes shall be maintained to ensure water efficiency. A regular maintenance schedule shall include but not limited to checking, adjusting, cleaning and repairing equipment; resetting the automatic controller, aerating and detaching turf areas; replenishing mulch; fertilizing; pruning; and weeding in all landscape areas. 2) Repair of irrigation equipment shall be done with the originally specified materials or their approved equivalents. Landscape Maintenance Schedule MAINTENANCE COMPANY TO PROVIDE AN IRRIGATION AUDIT, IN COMPLIANCE WITH THE STATE OF CALIFORNIA LANDSCAPE WATER MANAGEMENT PROGRAM, SHALL BE PERFORMED BY A CERTIFIED IRRIGATION AUDITOR PRIOR TO TURNOVER OF PROJECT AND EVERY 5 YEARS THEREAFTER. A SCHEDULE SHALL BE ESTABLISHED AND SUBMITTED TO THE CITY OF AT LEAST ONCE EVERY FIVE YEARS AS REQUIRED BY THE CITY. THE REGULAR MAINTENANCE SCHEDULE COUPLED WITH THE AUDITS SHOULD HELP TO MAINTAIN THE IRRIGATION EFFICIENCY AS INTENDED IN THE DESIGN. IRRIGATION SYSTEM SHALL BE TESTED AND MAINTAINED ON A MONTHLY BASIS BY THE MAINTENANCE STAFF. Irrigation Water Audit Note : THESE SUGGESTED RUN TIMES ARE FOR REFERENCE ONLY. ACTUAL RUN TIMES MAY DIFFER DUE TO VARYING SITE CONDITIONS. CONTRACTOR SHALL ADJUST RUN TIMES AS REQUIRED TO PROVIDE APPROPRIATE WATER FOR EACH VALVE CIRCUIT. 1. ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. 2. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE. 3. THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK. 4. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK. 5. THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN PLANTING AREAS. 6. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER. 7. INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION. 8. ACTUAL LOCATION FOR THE INSTALLATION OF THE AUTOMATIC CONTROLLER IS TO BE DETERMINED IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 9. CONTRACTOR IS TO PROVIDE AN ADDITIONAL PILOT WIRE FROM CONTROLLER ALONG ENTIRETY OF MAIN LINE TO THE LAST RCV ON EACH AND EVERY LEG OF MAIN LINE. LABEL SPARE WIRES AT BOTH ENDS. 10. ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING. 11. ALL REMOTE CONTROL VALVES TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHERE POSSIBLE. ALL REMOTE CONTROL VALVES TO BE INSTALLED AS SHOWN ON THE INSTALLATION DETAILS. INSTALL ALL REMOTE CONTROL VALVES WITHIN 18" OF HARDSCAPE. 12. ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE TO BE ADJUSTED TO PREVENT OVERSPRAY ONTO BUILDINGS, WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW, REPLACEMENT OF PRESSURE COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS UNITS AND THE REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS. 13. THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND RELATED EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. SUMMERS / MURPHY & PARTNERS INC. RECOMMENDS MEASURING FOR PROPER GROUND AT LEAST ONCE ANNUALLY, AND NECESSARY ADJUSTMENTS MADE TO COMPLY WITH MANUFACTURER SPECIFICATIONS. IRRIGATION NOTES WEEKLY ITEMS CHECK FLOW RATES FROM THE SMART CONTROLLER ON A DAILY BASIS TO CONFIRM THAT THE FLOWS FOR EACH CONTROL VALVE ARE CONSISTENT EVERY DAY. MONTHLY ITEMS CHECK AND CLEAN THE BASKET STRAINER OR BACKFLOW STRAINER SCREEN(S). DRIP IRRIGATION SYSTEM SHALL BE FLUSHED OF ALL ACCUMULATED DEBRIS. CHECK ALL AUTOMATIC FLUSH VALVES TO CONFIRM THAT THEY ARE OPERATING CORRECTLY AND THAT THE FLUSHED AREA IS NOT OVER SATURATED. IF OVER SATURATION OCCURS CORRECT THE PROBLEM AN NOTE IT IN ANNUAL REPORT. PROVIDE A REPORT IN A CHECKLIST FORM SHOWING WHAT WAS THE PROBLEM, DATE THE PROBLEM WAS FIRST KNOW, WHEN THE PROBLEM WAS CORRECTED, WHO CORRECTED THE PROBLEM. THIS REPORT SHALL BE TURNED OVER TO THE OWNER OR OWNER'S REPRESENTATIVE BY THE FIRST WEEK OF EACH MONTH. YEARLY ITEMS MAINTENANCE SCHEDULE VERIFY THE SMART CONTROLLER SERVICE IS OPERATIONAL AND CONFIRM ITS RENEWAL DATE. VERIFY THAT THE CURRENT TO THE REMOTE CONTROL VALVES IS WITHIN A MANUFACTURERS ACCEPTABLE RANGE. IF IT IS NOT, REPLACEMENT OF THE SOLENOID IS RECOMMENDED. SHOULD THIS NOT CORRECT THE ISSUE ADDITION TROUBLESHOOTING SHALL BE PERFORMED. PRESSURE REGULATING DEVICES ARE REQUIRED IF WATER PRESSURE IS BELLOW OR EXCEEDS THE RECOMMENDED PRESSURE OF THE SPECIFIED IRRIGATION DEVICES." CHECK VALVES OR ANTI-DRAIN VALVES ARE REQUIRED ON ALL SPRINKLER HEADS WHERE LOW POINT DRAINAGE COULD OCCUR. A DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDROZONES SHALL BE KEPT WITH THE IRRIGATION CONTROLLER FOR SUBSEQUENT MANAGEMENT PURPOSES. A CERTIFICATE OF COMPLETION SHALL BE FILLED OUT AND CERTIFIED BY EITHER THE DESIGNER OF THE LANDSCAPE PLANS, IRRIGATION PLANS, OR THE LICENSED LANDSCAPE CONTRACTOR FOR THE PROJECT. AN IRRIGATION AUDIT REPORT BY A DISINTERESTED 3RD PARTY SHALL BE COMPLETED AT THE TIME OF FINAL INSPECTION. NOTE: "I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND APPLIED THEM FOR EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLANS." SIGNATURE DATE 08/10/2021 XX XX XX XX VINE WITH THIS SYMBOL WILL REQUIRE: UXB-360-SPYK ADJUSTABLE EMITTER WITH STAKE, STUB OFF XT-700 TUBING SEE TREE/SHRUB PLAN FOR VINE QUANTITY AND LOCATIONS. EACH EMITTER ( STAKE) , AND (XQ DISTRIBUTION TUBING - MAX. LENGTH OF DISTRIBUTION TUBING TO BE 6', ADD STAKES AS NEEDED) SYMBOL INDICATES DRIPLINE TREE RING; XFS-CV-09-12 DRIP TUBING, INSTALL TWO RINGS PER TREE. SEE DETAIL FOR MANUFACTURERS INSTALLATION GUIDELINES. 'B' CONTROLLER TO BE LOCATED AT LOT 95 AND TO BE REMOVED UPON BUILD OUT OF LOT 94 PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER SMP SMP SMP IRRIGATION DETAILS 177-ID ID-2 11 LOCK TABS PREVENT WIRE REMOVAL INTO THE CONNECTIOR. TWIST CONNECTOR ONTO WIRES TO INSULATION PRIOR TO INSERTION PRE-STRIPPED OF 1/2" OF THE CONNECTOR. WIRES SHALL BE SCOTCHLOK ELECTRICAL SPRING ONCE CONNECTOR IS INSERTED CONNECTOR PASSES LOCK TABS SCOTCHLOK CONNECTOR AND WIRES INSERTED INTO TUBE UNTIL THE 2 #12 PRE-STRIPPED COPPER WIRES. LARGER WIRES OR GREATER QUANTITIES OF WIRES DIRECT BURY SPLICE KIT SHALL BE USED TO ELECTRICALLY CONNECT 2 - 3 #14 OR KIT SHALL INCLUDE A SCOTCHLOK SPRING CONNECTOR, A POLYPROPYLENE TUBE AND A WIRE CONNECTOR SHALL BE A 3M DBY DIRECT BURY SPLICE KIT. WATERPROOF SEALING GEL. TUBE SHALL BE SUPPLIED PREFILLED WITH GEL. NOTE: SEAT FIRMLY. LOW VOLTAGE WIRES, 3 MAXIMUM CLOSE TUBE LID AFTER WIRE TUBE LID TO ALLOW LID TO CLOSE WIRES PASS THROUGH GROOVES IN IS INSERTED INTO TUBE POLY TUBE PRE-FILLED WITHWATERPROOF GEL SHALL REQUIRE A LARGER APPROVED WIRE CONNECTION. SECTION VIEW - N.T.S. 24" 24" 18" ALL PLASTIC PIPING SHALL BE SNAKED WITHIN TRENCH. BUNDLE WIRING AND WRAP WITH TAPE AT TEN FOOT INTERVALS. ALL MAINLINE PIPING TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS 3" AND LARGER 2" TO 2 1/2" IN SIZE 1/2" TO 1 1/2" SIZE SECTION VIEW - N.T.S. INSTALLATION SPECIFICATIONS. NOTE: 18" 12" 12" DIMENSION A E E D FE A B E B F C 6"24" 18" 24" 30" 30" 6" 6" 6" CLEAN SAND BACKFILL, UNDISTURBED SOIL IN SCH. 40 CONDUIT INSTALL AT MAINLINE DEPTH 120 VOLT ELECTRICAL SPECIFICATIONS PRESSURE MAINLINE, SEE CONTROL WIRES, SEE SPECS. LATERAL LINES, SEE SPECS. CLEAN COMPACTED BACKFILL C E D E F FINISHED GRADE 6" 6" SEE SPECIFICATIONS ALL CURBS SHALL BE MARKED WITH A "SCORE" MARK TO DESIGNATE SLEEVE LOCATION. ALL PVC MAINLINE, PVC LATERAL LINES, AND CONTROL WIRES SHALL BE SLEEVED BELOW ALL HARDSCAPE ELEMENTS WITH SCH. 40 PVC, 2 TIMES THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. PLAN VIEW - N.T.S. NOTE: DEPTH BELOW GRADE DIMENSION SECTION VIEW - N.T.S. E E 24" A 36" B E E AD B C 30 DEGREES, UNTIE AFTER ALL CONECTIONSCHANGES OF DIRECTION GREATER THAN TIE A 36" LOOP IN ALL WIRING AT HAVE BEEN MADE. IN SCH. 40 SLEEVE120 VOLT ELECTRICAL EXISTING SOIL BUNDLE CARRIED. OF THE PIPE OR WIRE TWICE THE DIAMETER PVC SLEEVES TO BE IN SCH. 40 SLEEVE IN SCH. 40 SLEEVE IN SCH. 40 SLEEVE CONTROL WIRES PRESSURE MAINLINE LATERAL LINES TO THE DENSITY OFSAND BACKFILL COMPACTED UNDISTURBED SOIL PAVING OR D.G. PATH 36" D 36" C 6" E E SLEEVE DETAIL SHALL ALSO BE USED FOR INSTALLATION OF PIPE IN ROCK SOIL. 3" TO THE INSTALLATION OF THE TUBING. RECOMMENDED INSTALLATION: WIRE HOOP STAKES AT 5 FEET ON CENTER SPACING. THE SOIL LEVEL IN THE PLANTER AREAS BE BROUGHT TO 4 1/2" BELOW FINISHEDGRADE AND PROPERLY COMPACTED AS PER THE LANDSCAPED DRAWINGS PRIOR BACKFILL FINAL 3" OF BARK MULCH OVER THE TUBING AFTER INSTALLATION OF INSTALL TUBING AS INDICATED ON THESE DRAWINGS AND SECURE TO GRADE USING TO INSURE EVEN PARALLEL AND LEVEL TUBING ROWS IT IS RECOMMENDED THAT AMMENDED SOIL* BARK MULCHINSTALLED AFTER TUBING INSTALLATION FINISHED GRADE TUBING INSTALLATION BRING SOIL LEVEL * AS PER LANDSCAPE DRAWINGS WIRE STAKE TO 4 1/2" BELOW PRIOR TO DRIP DRIP TUBING 1/2" SCH 40 PVC THREADED TEE FITTING THREADED ENDS SCH 80 PVC NIPPLE 1/2" X 6" MINIMUM KING BROTHERS INDUSTRIES FLEXIBLE SIZE: HEADER X HEADER X 1/2" NIPPLE, 1/2" X 6", WITH FNPT X MNPT SCH 40 PVC S X S X FNPT TEE FITTING, PVC HEADER LINE, SUPPLY OR DISCHARGE 6" JUTE WIRE STAPLE, INSTALL TOHOLD DOWN TUBING, 5 FEET ON CENTER 12" ALONG LENGTH OF TUBING 3" OF BARK MULCH TO COMPLETELYCOVER THE DRIP TUBING LANDSCAPE DRIP LINE, LENGTH, THREADED BOTH ENDS AMENDED SITE SOIL, SEE PLANTING PLANS 3" SECTION VIEW - N.T.S. WITH TWO (1/2") BARB MALE ADAPTERS TUBING INSTALLED IN PARALLEL ROWS, SPACING AS INDICATED ON THE LEGEND. NOTE: 17mm OUTSIDE DIAMETER FINISHED GRADE OF AMENDED SOIL FINISH GRADE 12" 3" ADAPTER (TYP) COMPRESSION PVC ELL TO MANIFOLD DRIPLINE PVC TEE (TYP) SUPPLY PVC HEADER FLEXIBLE HOSE NOTES: 1. SEE IRRIGATION NOTES,LEGEND/SPECIFICATIONS FOR ALL DIMENSIONSAND LATERAL AND INLINE SPACING 2. ALL FITTINGS TO BE USED WILL BE PER MANUFACTURERSSPECIFICATIONS. USE COMPRESSION FITTINGS ONLY OR APPROVED EQUAL METAL STAKES (SEE NOTE 3) 3. TUBING HAS BEEN PLOWED IN, NO STAKING IS NECESSARY.AND AS NECESSARY TO INSURE SECURITY 4" BELOW GRADE. IF DRIPIF DRIP TUBING HAS BEEN HAND DUG IN, STAKE DRIPLINE AT 4' O.C. 3" 3" DRIPLINE CROSS COMPRESSION FINISH GRADE BLANK DRIPLINE METAL STAKES (SEE NOTE 3) VALVE & VALVE AIR VACUUM RELIEF BOX AT HIGHEST POINTS KING BROTHERS FLEXIBLENIPPLE, 1/2" X 6", W/ FNPT X MNPT 3. ALL FITTINGS TO BE USED WILL BE PER MANUFACTURERSSPECIFICATIONS USE COMPRESSION FITTINGS ONLY OR APPROVED EQUAL NOTES: 1. SEE IRRIGATION NOTES,LEGEND/SPECIFICATIONSFOR ADDITIONAL INFORMATION 4. RUN TUBING PARALLEL TO SLOPE. IN THE UPPER 2/3rd's OF THE SLOPE,SPACE TUBING AT 14-16". IN THE LOWER 1/3 OF THE SLOPE, INCREASEDISTANCE BETWEEN ROWS BY 25% OR APPROXIMATELY 22-1/2" 5. INSTALL CHECK VALVES IN SUPPLY AND FLUSH MANIFOLD LINE AS DETAILED / AS REQUIREDTO DETER DRAIN DOWN. 2. IF DRIP TUBING HAS BEEN HAND DUG IN, STAKE DRIPLINE AT 4' O.C. AND AS NECESSARY TOINSURE SECURITY 4" BELOW GRADE. IF DRIP TUBING HAS BEEN PLOWED IN, NO STAKING ISNECESSARY. 1/2" 3" B PRESSURE REGULATORC BALL VALVEDANTI-SIPHON VALVEA DRIP ANTI-SIPHON VALVEF POP-UP SPRINKLERE PRIVATE LOT POCG WALL MOUNT CONTROLLERI JWIRE CONNECTIONH DRIP FLUSH VALVEL DRIP AIR RELIEF VALVEM BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE COVER, USE STAINLESS BOLT, NUT, AND WASHER. PLASTIC RECTANGULAR VALVE BOX WITH BOLT DOWN EDGE. HEAT BRAND "BV" ONTO LID. INSTALL VALVE BOX EXTENSIONS AS REQ. TO ACHIEVE PROPER VALVE AND PIPE DEPTH BOX TO BE INSTALLED AS TO ALLOW FOR PROPER OPERATION OF BALL VALVE, INSTALL VALVE AND BOX PARALLEL TO HARDSCAPE EDGE, INSTALL BOX OFF-CENTER OF VALVE. BRASS BALL VALVE, SEE LEGEND FOR SPECIFICATION NOTE: 2" FLOW 4" UP AND OVER BOX HOLES BALL VALVE VALVE BOX PVC MAINLINE PIPE SCH. 80 PVC NIPPLE 3/4" ROCK, 3 CUBIC FT. LANDSCAPE FABRIC, WRAP 4 REQ PER BOX BALL VALVE USING TWO FINISHED GRADE TRANSITION UP AND DOWN IN SHRUB AREAS BRICK SUPPORTS 2" SECTION VIEW - N.T.S. SCH. 80 PVC UNION SCH. 80 PVC T.O.E. NIPPLELENGTH AS REQ., TYPICAL SCH. 80 PVC 45 DEGREE TO MAINLINE DEPTH FOR PLAN VIEW - N.T.S. 1/2" PVC MAINLINE PIPE, SEESPECIFICATIONS, TYPICAL ELLS, BOTH SIDES OFBALL VALVE WRAP LANDSCAPE FABRIC AROUND SIDES AND BOTTON OF BOX TO COVER ALL OPENINGS. POINT SOURCE FOR POTTED PLANTS W E C R 5 4 5 3 2 1 3 21 7 6 4 RAIN BIRD 1 GAL= (1) UXB-360-SPYK 5 GAL= (1) UXB-360-SPYK TUBING STAKE: RAIN BIRD UXB-360-SPYK 14" DISTRIBUTION TUBING: TUBING (6' MAXIMUM LENGTH) SECURE TUBING TO BACK OF POT AWAY FROM VIEWS RAIN BIRD BARB TEE OR COUPLING POTTED PLANT SOIL FINISH GRADE POLYETHYLENE TUBING: DRIP TUBING (SEE LEGEND). 9 8 3" BARK MULCH 9 FOOTING / POTTED PLANT PLATFORM THE TUBING SUB-SURFACE DRIPLINEK SLEEVE INSTALLATIONN PIPE INSTALLATIONO TURF ROTOR 1/2" FINISH GRADE PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER SMP SMP SMP IRRIGATION SPECIFICATIONS 177-ID ID-3 12 PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE SIDEYARD MULCH 1234567DODONAEA V. 'PURPUREA'15 GAL. MEDPURPLE LEAFED HOP BUSH COLUMNAR GEIJERA PARVIFLORA 36" BOX MED.AUSTRALIAN WILLOW LOW BRANCH OLEA EUROPAEA 14' B&B LOWOLIVE TREE SYMMETRICALSHAPE TREE & VINE LEGEND (PLANT QUANTITIES FOR THIS SHEET ONLY) SYM BOTANICAL/COMMON NAME SIZE WUCOL QTY. 6 11 2 1 7 13 13 24 33 LOT 94 | PARKING LOT GEIJERA PARVIFLORA 36" BOX MED.AUSTRALIAN WILLOW LOW BRANCH OLEA EUROPAEA 'SWAN HILL'36" BOX LOW SWANHILL OLIVE LOW BRANCHMATCHING PRUNUS CARASIFERA 36" BOX MED'KRAUTER VESUVIUS'SINGLE TRUNKPURPLE-LEAF PLUM PRUNUS C. 'COMPACTA' 24" BOX MEDCHERRY LAUREL COLUMNAR FICUS CARICA (FIG)15 GAL MED(OR OTHER RECOMENDED LOCAL FRUIT TREE) LIGUSTRUM J. 'TEXANUM'15 GAL MEDWAXLEAF PRIVET ESPALIER LOT 95 | PLAN S852-AL (PENDLETON/ SPANISH SALES OFFICE) DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER 0 10 20 30 40 SCALE: 1" = 10' - 0" NORTHMATCH L INE : SEE SHEE T PT - 2 SMP SMP SMP TREE & VINE PLANTING LAYOUT 177-PT PT-1 13 RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMP N.T.S.KEYMAP PT-1 PLANTING NOTES: 1. AT THE CONCLUSION OF ROUGH GRADING, AN AGRONOMIC SOILS REPORT SHALL BE OBTAINED BY THE CONTRACTOR. RECOMMENDATIONS FROM SUCH REPORT SHALL BE INCORPORATED BY THE CONTRACTOR INTO INSTALLATION OF PLANTING AREAS. 2. TREE AND SHRUB MATERIAL SPECIFIED MUST MEET STANDARD INDUSTRY SPECIFICATIONS FOR THE CONTAINER SIZE INDICATED. IF THE CONTRACTOR CANNOT LOCATE MATERIAL OF ACCEPTABLE SIZE AT THE TIME OF INSTALLATION, CONTACT LANDSCAPE ARCHITECT FOR SPECIES SUBSTITUTION; DOWNSIZING OR SUBSTITUTION OF PLANT MATERIAL WITHOUT PRIOR APPROVAL OF LANDSCAPE ARCHITECT WILL NOT BE ALLOWED. 3. CONCEAL IRRIGATION VALVES IN SHRUB AREAS. 4. TREES SHALL NOT BE PLANTED CLOSER THAN FOUR (4) FEET FROM ANY WALKWAY OR PUBLIC SIDEWALK EXCEPT WHERE TREE WELLS OR PARKWAYS ARE PROVIDED IN THE SIDEWALK AREA. ALL TREE PLANTED WITHIN SIX (6)FEET OF WALKS OR PUBLIC UTILITIES SHALL RECEIVE DEEP ROOT BARRIERS. 5. TREE LOCATIONS SHOWN ON PLAN MAY REQUIRE ADJUSTMENT IN THE FIELD. WHENEVER FEASIBLE, TREES SHOULD BE PLANTED A MINIMUM OF TEN (10)FEET FROM ALL UNDERGROUND UTILITIES, STREETLIGHTS, HYDRANTS, AND OUT OF DRAINAGE FLOW LINES. SHOULD THIS NOT BE POSSIBLE, CONTACT THE LANDSCAPE ARCHITECT FOR DECISION ON PLACEMENT. 6. GROUNDCOVER TYPE SHOWN SHALL BE PLANTED IN SHRUB AREAS AS SPECIFIED ON PLANS. GROUNDCOVER SHALL BE PLANTED AT 18" ON-CENTER UNIFORM TRIANGULAR SPACING, AND SHALL BE CONTINUOUS UNDER TREE AND SHRUB MASSES AS SHOWN ON PLAN. 7. CONTRACTOR / DEVELOPER IS TO CONTACT THE COUNTY FOR A FINAL INSPECTION OF THE LANDSCAPE ONCE ALL WORK IS COMPLETE. 8. CONTRACTOR IS TO PROVIDE COPIES OF SOIL AMENDMENT DELIVERY TICKETS TO THE COUNTY INSPECTOR AT THE FINAL INSPECTION. 9. MATURE PLANTINGS SHALL NOT INTERFERE WITH UTILITIES AND TRAFFIC SIGHT LINES. 10. ALL BOXED TREES TO BE TAGGED BY LANDSCAPE ARCHITECT. 11. ALL PLANTING BEDS TO RECEIVE A 3" THICK TOP DRESSING OF 'FORESTFLOOR' ORGANIC BARK MULCH OR APPROVED EQUAL (SEE PLANTING DETAILSSHEET), INCLUDING SIDEYARDS. 12. ATTACH ESPALIER TO TRELLIS STRUCTURE, REMOVE NURSERY STAKES. PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE TREE & VINE LEGEND (PLANT QUANTITIES FOR THIS SHEET ONLY) SYM BOTANICAL/COMMON NAME SIZE WUCOL QTY. 1 3 10 29 10 4 13 8 1 21 OLEA EUROPAEA 14' B&B MED.OLIVE TREE SYMMETRICALSHAPE PISTACIA CHINENSIS 'RED PUSH' 36" BOX MED.RED PUSH PISTACIA STD, PROSOPIS X 'PHOENIX'36" BOX LOWTHORNLESS S. AMERICAN MESQUITE MULTI-TRUNK PYRACANTHA 'GRABERI'15 GAL LOWGRABER'S PYRACANTHA ESPALIER LOT 96 | PLAN 853-BL (PINECREST/ FARMHOUSE) CALLISTEMON CISTRINUS 36" BOX MED CRIMSON BOTTLEBRUSH MATCHING CERCIDIUM 'DESERT MUSEUM' 36" BOX MED DESERT MUSEUM PALO VERDE MULTI-TRUNKSYMMETRICAL DODONAEA V. 'PURPUREA'24" BOX MEDPURPLE LEAFED HOP BUSH COLUMNAR ULMUS PARVIFOLIA 'TRUE GREEN' 36" BOX MEDPURPLE LEAFED HOP BUSH STDSYMMETRICAL ULMUS PARVIFOLIA 'TRUE GREEN' 48" BOX MEDPURPLE LEAFED HOP BUSH STDSYMMETRICAL PHOTINIA X FRASERIA 'RED ROBIN' 15 GAL. MEDFRASER PHOTINIA ESPALIER LOT 97 | PLAN S850-CL (POMONA/ CONTEMPORARY PREIRIE) LOT 97 PLAN: S850-CL POMONA/ CONTEMPORARY PRAIRIE LOT 96 PLAN: S853-BL PINECREST/ MONTEREY LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE MLS LMS MSL SIDEYARD MULCH DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER 0 10 20 30 40 SCALE: 1" = 10' - 0" NORTH SMP SMP SMP TREE & VINE PLANTING LAYOUT 177-PT PT-2 14 RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMP N.T.S.KEYMAP PT-2 PLANTING NOTES: 1. AT THE CONCLUSION OF ROUGH GRADING, AN AGRONOMIC SOILS REPORT SHALL BE OBTAINED BY THE CONTRACTOR. RECOMMENDATIONS FROM SUCH REPORT SHALL BE INCORPORATED BY THE CONTRACTOR INTO INSTALLATION OF PLANTING AREAS. 2. TREE AND SHRUB MATERIAL SPECIFIED MUST MEET STANDARD INDUSTRY SPECIFICATIONS FOR THE CONTAINER SIZE INDICATED. IF THE CONTRACTOR CANNOT LOCATE MATERIAL OF ACCEPTABLE SIZE AT THE TIME OF INSTALLATION, CONTACT LANDSCAPE ARCHITECT FOR SPECIES SUBSTITUTION; DOWNSIZING OR SUBSTITUTION OF PLANT MATERIAL WITHOUT PRIOR APPROVAL OF LANDSCAPE ARCHITECT WILL NOT BE ALLOWED. 3. CONCEAL IRRIGATION VALVES IN SHRUB AREAS. 4. TREES SHALL NOT BE PLANTED CLOSER THAN FOUR (4) FEET FROM ANY WALKWAY OR PUBLIC SIDEWALK EXCEPT WHERE TREE WELLS OR PARKWAYS ARE PROVIDED IN THE SIDEWALK AREA. ALL TREE PLANTED WITHIN SIX (6)FEET OF WALKS OR PUBLIC UTILITIES SHALL RECEIVE DEEP ROOT BARRIERS. 5. TREE LOCATIONS SHOWN ON PLAN MAY REQUIRE ADJUSTMENT IN THE FIELD. WHENEVER FEASIBLE, TREES SHOULD BE PLANTED A MINIMUM OF TEN (10)FEET FROM ALL UNDERGROUND UTILITIES, STREETLIGHTS, HYDRANTS, AND OUT OF DRAINAGE FLOW LINES. SHOULD THIS NOT BE POSSIBLE, CONTACT THE LANDSCAPE ARCHITECT FOR DECISION ON PLACEMENT. 6. GROUNDCOVER TYPE SHOWN SHALL BE PLANTED IN SHRUB AREAS AS SPECIFIED ON PLANS. GROUNDCOVER SHALL BE PLANTED AT 18" ON-CENTER UNIFORM TRIANGULAR SPACING, AND SHALL BE CONTINUOUS UNDER TREE AND SHRUB MASSES AS SHOWN ON PLAN. 7. CONTRACTOR / DEVELOPER IS TO CONTACT THE COUNTY FOR A FINAL INSPECTION OF THE LANDSCAPE ONCE ALL WORK IS COMPLETE. 8. CONTRACTOR IS TO PROVIDE COPIES OF SOIL AMENDMENT DELIVERY TICKETS TO THE COUNTY INSPECTOR AT THE FINAL INSPECTION. 9. MATURE PLANTINGS SHALL NOT INTERFERE WITH UTILITIES AND TRAFFIC SIGHT LINES. 10. ALL BOXED TREES TO BE TAGGED BY LANDSCAPE ARCHITECT. 11. ALL PLANTING BEDS TO RECEIVE A 3" THICK TOP DRESSING OF 'FORESTFLOOR' ORGANIC BARK MULCH OR APPROVED EQUAL (SEE PLANTING DETAILSSHEET), INCLUDING SIDEYARDS. 12. ATTACH ESPALIER TO TRELLIS STRUCTURE, REMOVE NURSERY STAKES.MATCH L INE : SEE SHEE T PT - 1 PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE SHRUB PLANTING LEGEND SYMBOL BOTANICAL/COMMON NAME SIZE FORM WUCOLS QTY @ 30" O.C. ABELIA GRANDIFLORA 5 GAL GLOSSY ABELIA @ 2' O.C. BERBERIS THUNBERGII 5 GAL 'CRIMSON PYGMY' @ 42" O.C. ROSA FLORIBUNDA 'ICEBERG WHITE' 5 GAL ROSA SPP. ROSA FLORIBUNDA 5 GAL LOW BRANCH MATCHING'ICEBERG BURGUNDY'@ 42" O.C. @ 4' O.C. ABELIA GRANDIFLORA 5 GAL GLOSSY ABELIA @ 3' O.C. NASSELLA TENUISSIMA 5 GAL MEXICAN FEATHERGRASS BURGUNDY ICEBERG ROSE ROSA FLORIBUNDA ' ICEBERG PINK' 5 GAL COLUMNAL PINK ICEBERG ROSE @ 42" O.C. @ 4' O.C. LIGUSTRUM J. TEXANUM 15 GAL WEXLEAF PRIVET JAPANESE BARBERRY @ 42" O.C. ROSA 'DOUBLE KNOCKOUT' 15 GAL DOUBLE KNOCK OUT ROSE @ 3' O.C. RHAPHIOLEPIS 'PINK LADY' 15 GAL INDIAN HAWTHORN ROSA 'NOARE'5 GAL LOW BRANCH MATCHINGRED FLOWER CARPET @ 2' O.C. HESPERALOE PARVIFLORA 5 GAL COLUMNAL 'PERPA BRAKELIGHTS' @ 2' O.C. BRAKELIGHTS HESPERALOE LOT 96 | PLAN 853-BL (PINECREST/ FARMHOUSE) LOT 95 | PLAN S852-AL (PENDLETON/ SPANISH SALES OFFICE) LOT 94 | PARKING LOT SYMBOL BOTANICAL/COMMON NAME SIZE FORM WUCOLS QTY 129 78 12 M M M M M 88 27 L 195 8M M 40 18 61 M L M 40 79L LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE SIDEYARD MULCH 1234567DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER 0 10 20 30 40 SCALE: 1" = 10' - 0" NORTH SMP SMP SMP SHRUB PLANTING LAYOUT 177-PS PS-1 15 RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMP N.T.S.KEYMAP PS-1MATCH L INE : SEE SHEE T PS- 2 PLANTING NOTES: 1. AT THE CONCLUSION OF ROUGH GRADING, AN AGRONOMIC SOILS REPORT SHALL BE OBTAINED BY THE CONTRACTOR. RECOMMENDATIONS FROM SUCH REPORT SHALL BE INCORPORATED BY THE CONTRACTOR INTO INSTALLATION OF PLANTING AREAS. 2. TREE AND SHRUB MATERIAL SPECIFIED MUST MEET STANDARD INDUSTRY SPECIFICATIONS FOR THE CONTAINER SIZE INDICATED. IF THE CONTRACTOR CANNOT LOCATE MATERIAL OF ACCEPTABLE SIZE AT THE TIME OF INSTALLATION, CONTACT LANDSCAPE ARCHITECT FOR SPECIES SUBSTITUTION; DOWNSIZING OR SUBSTITUTION OF PLANT MATERIAL WITHOUT PRIOR APPROVAL OF LANDSCAPE ARCHITECT WILL NOT BE ALLOWED. 3. CONCEAL IRRIGATION VALVES IN SHRUB AREAS. 4. TREES SHALL NOT BE PLANTED CLOSER THAN FOUR (4) FEET FROM ANY WALKWAY OR PUBLIC SIDEWALK EXCEPT WHERE TREE WELLS OR PARKWAYS ARE PROVIDED IN THE SIDEWALK AREA. ALL TREE PLANTED WITHIN SIX (6)FEET OF WALKS OR PUBLIC UTILITIES SHALL RECEIVE DEEP ROOT BARRIERS. 5. TREE LOCATIONS SHOWN ON PLAN MAY REQUIRE ADJUSTMENT IN THE FIELD. WHENEVER FEASIBLE, TREES SHOULD BE PLANTED A MINIMUM OF TEN (10)FEET FROM ALL UNDERGROUND UTILITIES, STREETLIGHTS, HYDRANTS, AND OUT OF DRAINAGE FLOW LINES. SHOULD THIS NOT BE POSSIBLE, CONTACT THE LANDSCAPE ARCHITECT FOR DECISION ON PLACEMENT. 6. GROUNDCOVER TYPE SHOWN SHALL BE PLANTED IN SHRUB AREAS AS SPECIFIED ON PLANS. GROUNDCOVER SHALL BE PLANTED AT 18" ON-CENTER UNIFORM TRIANGULAR SPACING, AND SHALL BE CONTINUOUS UNDER TREE AND SHRUB MASSES AS SHOWN ON PLAN. 7. CONTRACTOR / DEVELOPER IS TO CONTACT THE COUNTY FOR A FINAL INSPECTION OF THE LANDSCAPE ONCE ALL WORK IS COMPLETE. 8. CONTRACTOR IS TO PROVIDE COPIES OF SOIL AMENDMENT DELIVERY TICKETS TO THE COUNTY INSPECTOR AT THE FINAL INSPECTION. 9. MATURE PLANTINGS SHALL NOT INTERFERE WITH UTILITIES AND TRAFFIC SIGHT LINES. 10. ALL BOXED TREES TO BE TAGGED BY LANDSCAPE ARCHITECT. 11. ALL PLANTING BEDS TO RECEIVE A 3" THICK TOP DRESSING OF 'FORESTFLOOR' ORGANIC BARK MULCH OR APPROVED EQUAL (SEE PLANTING DETAILSSHEET), INCLUDING SIDEYARDS. 12. ATTACH ESPALIER TO TRELLIS STRUCTURE, REMOVE NURSERY STAKES. PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE SHRUB PLANTING LEGEND SYMBOL BOTANICAL/COMMON NAME SIZE FORM WUCOLS QTY L L L L L L 41 80 83 92 103 55 M 13 L 20 L 22 L 81 M 26 L 11 @ 6' O.C. VITIS SPP. 1 GAL GRAPE (BEST LOCAL GRAPE) @ 18" O.C. ALOE 'BLUE ELF' 1 GAL CALIFORNIA ALOE @ 4' O.C. YUCCA RECURVIFOLIA 15 GAL CURVE LEAF YUCCA @ 3' O.C. AGAVE ATTENUATA 5 GAL FOXTAIL @ 2' O.C. ALOE STRIATA 'GHOST ALOE' 5 GAL CHOST ALOE @ 3' O.C. PENNISETUM ADVENA 'RUBRUM' 5 GAL RED FOUNTAIN GRASS @ 12" O.C. EQUISETUM HYEMALE 5 GAL ROUGH HORSETAIL @ 3' O.C. MUHLENBERGIA RIGENS 5 GAL DEER GRASS @ 3' O.C. ROSMARINUS O. 'TUSCAN BLUE' 15 GAL UPRIGHT ROSEMARY @ 2' O.C. ALOE VERA 5 GAL ALOE VERA @ 3' O.C. MUHLENBERGIA C. 'REGAL MIST' 5 GAL PINK MUHLY GRASS @ 3' O.C. PEDILANTHUS BRACTEATUS 15 GALTROPIC-TILLO LOT 97 | PLAN S850-CL (POMONA/ CONTEMPORARY PREIRIE) LOT 96 | PLAN 853-BL (PINECREST/ FARMHOUSE) SYMBOL BOTANICAL/COMMON NAME SIZE FORM WUCOLS QTY LOT 97 PLAN: S850-CL POMONA/ CONTEMPORARY PRAIRIE LOT 96 PLAN: S853-BL PINECREST/ MONTEREY LOT 95 PLAN: S852-AL PENDLETON/ SPANISH SALES OFFICE MLS LMS MSL SIDEYARD MULCH DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER 0 10 20 30 40 SCALE: 1" = 10' - 0" NORTH SMP SMP SMP SHRUB PLANTING LAYOUT 177-PS PS-2 16 RESIDENZA COURT PASATIEMPO COURT IL SERENATA DRIVEARPEGGIO DRIVE FIORI DEL DESERTO DRIVEVIA PASATIEMP N.T.S.KEYMAP PS-2 PLANTING NOTES: 1. AT THE CONCLUSION OF ROUGH GRADING, AN AGRONOMIC SOILS REPORT SHALL BE OBTAINED BY THE CONTRACTOR. RECOMMENDATIONS FROM SUCH REPORT SHALL BE INCORPORATED BY THE CONTRACTOR INTO INSTALLATION OF PLANTING AREAS. 2. TREE AND SHRUB MATERIAL SPECIFIED MUST MEET STANDARD INDUSTRY SPECIFICATIONS FOR THE CONTAINER SIZE INDICATED. IF THE CONTRACTOR CANNOT LOCATE MATERIAL OF ACCEPTABLE SIZE AT THE TIME OF INSTALLATION, CONTACT LANDSCAPE ARCHITECT FOR SPECIES SUBSTITUTION; DOWNSIZING OR SUBSTITUTION OF PLANT MATERIAL WITHOUT PRIOR APPROVAL OF LANDSCAPE ARCHITECT WILL NOT BE ALLOWED. 3. CONCEAL IRRIGATION VALVES IN SHRUB AREAS. 4. TREES SHALL NOT BE PLANTED CLOSER THAN FOUR (4) FEET FROM ANY WALKWAY OR PUBLIC SIDEWALK EXCEPT WHERE TREE WELLS OR PARKWAYS ARE PROVIDED IN THE SIDEWALK AREA. ALL TREE PLANTED WITHIN SIX (6)FEET OF WALKS OR PUBLIC UTILITIES SHALL RECEIVE DEEP ROOT BARRIERS. 5. TREE LOCATIONS SHOWN ON PLAN MAY REQUIRE ADJUSTMENT IN THE FIELD. WHENEVER FEASIBLE, TREES SHOULD BE PLANTED A MINIMUM OF TEN (10)FEET FROM ALL UNDERGROUND UTILITIES, STREETLIGHTS, HYDRANTS, AND OUT OF DRAINAGE FLOW LINES. SHOULD THIS NOT BE POSSIBLE, CONTACT THE LANDSCAPE ARCHITECT FOR DECISION ON PLACEMENT. 6. GROUNDCOVER TYPE SHOWN SHALL BE PLANTED IN SHRUB AREAS AS SPECIFIED ON PLANS. GROUNDCOVER SHALL BE PLANTED AT 18" ON-CENTER UNIFORM TRIANGULAR SPACING, AND SHALL BE CONTINUOUS UNDER TREE AND SHRUB MASSES AS SHOWN ON PLAN. 7. CONTRACTOR / DEVELOPER IS TO CONTACT THE COUNTY FOR A FINAL INSPECTION OF THE LANDSCAPE ONCE ALL WORK IS COMPLETE. 8. CONTRACTOR IS TO PROVIDE COPIES OF SOIL AMENDMENT DELIVERY TICKETS TO THE COUNTY INSPECTOR AT THE FINAL INSPECTION. 9. MATURE PLANTINGS SHALL NOT INTERFERE WITH UTILITIES AND TRAFFIC SIGHT LINES. 10. ALL BOXED TREES TO BE TAGGED BY LANDSCAPE ARCHITECT. 11. ALL PLANTING BEDS TO RECEIVE A 3" THICK TOP DRESSING OF 'FORESTFLOOR' ORGANIC BARK MULCH OR APPROVED EQUAL (SEE PLANTING DETAILSSHEET), INCLUDING SIDEYARDS. 12. ATTACH ESPALIER TO TRELLIS STRUCTURE, REMOVE NURSERY STAKES.MATCH L INE : SEE SHEE T PS- 1 PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER SMP SMP SMP PLANTING DETAILS 177-PD PD-1 17 VINE PLANTING 4 SHRUB PLANTING 1 PLANTING TABLET SCHEDULE 5 TREE PLANTING 2 ROOT CONTROL BARRIERCONCRETE MOWCURB 4 SHRUB PLANTING4SHRUB PLANTING 4 4 SCALE: N.T.S. SECTION VIEW LEGEND EQUALEQUAL2XROOTBALL DIA. 11 12 MIN. TWO TIES (TOP & BOTTOM) REQUIRED. USE THIRD TIE WHEN NECESSARY TO HOLD TREE IN UPRIGHT POSITION. TIES TO BE SECURED TO AVOID SLIPPAGE (WRAP STAKE TO FORM FIGURE EIGHT. NAIL W/ (1) GALV. NAIL THROUGH EACH FOR 24" AND 36" BOX TREES SUMP - REFER TO DETAIL TIE INTO POLE. 10 END OF TURF 8 7 9 5 6 NOTE: 11. 12. PREVAILING WIND 6"12"PLAN 12"12" LODGEPOLE PINE STAKE COPPER NAPHTHENATE IMPREGNATED. 2-1/2" DIA.x 12' LONG FOR 24" BOX TOP OF ROOT BALL TO BE1" ABOVE FINISH GRADE 3" HIGH WATER BASIN 2" LAYER OF MULCH SCHEDULE FOR QTY.PLANTING TABLET - SEE BACKFILL MIX - SEE 5. FINISH GRADE SOILS REPORT NATIVE SUBGRADE SEE SPECS ROOTBALL 2 3 4 8. 9. 10. 1 6. 7. (619) 673-1760 AND SMALLER. 4. 3. 2. 'CINCH-TIE' BY V.I.T. CO.1. PLANT PIT EXCAVATION AMENDED SOIL FOR PLANTING - REFER TO SOILS REPORT PLANTING TABLETS - REFER TO SCHEDULE FOR QTY. TREE OR SHRUB - SIZE PER PLAN OF ROOT BALL2 X DIAMETER EXISTING SLOPE NATIVE SUBGRADE ROOTBALL 10. 9. 8. 7. FINISH GRADE 3" WATER BASIN 2" LAYER OF MULCH 3. 4. 5. 6. 1. 2.3"7 9 8 6 5 4 3 2 1 10 LEGEND SECTION VIEW SCALE: N.T.S. SCALE: N.T.S. SECTION VIEW 5' NATIVE SUBGRADE ROOT BALL CONCRETE PAVING - REFERTO PLANS ONE PIECE, MOLDED ANDRIBBED ROOT BARRIER. RIBS TO BE A MINIMUM OF 1/8" WIDE X 1/2" DEEP, ROOT BARRIER TO BE MADE OF POLYETHYLENE PLASTIC W/ULTRAVIOLET INHIBITORS, .085" THICK MIN. 24" HIGH X 10' LONG (5' EACH SIDE OF TRUNK) AMENDED BACKFILL MIX 2 OF ROOT BALL2 X DIAMETERDEPTH OFROOT BALL5 5. 4. 3. 3 4 N.T.S. 1 1. 2. TREE TRUNK PLAN BARRIER ROOT CONTROL 5' CL PLANTER SIDEWALK PL-RC-01AND FACING THE TREE. REFER TO PLAN ABOVE. PLACE LINEAR BARRIERS AGAINST PAVING - BOTH SIDES ROOT CONTROL FOR TREES 5' FROM ANY HARDSCAPE. FOR STAKING, REFER TO TREE STAKING DETAIL. FOR PLANTING, REFER TO TREE PLANTING DETAIL. FINISH GRADE TO BE LEVEL WITH TOP OF CURB. NOTES: LEGEND LEGEND 2 X DIAMETER 1 2 3 7 5 6 8 7. 6. 5. 4. 3. 2. 1. 1, 5, OR 15 GALLON SHRUB 2" LAYER OF MULCH 3" WATER BASIN AMENDED SOIL FOR PLANTING - REFER TO SOILS REPORT PLANT PIT EXCAVATION ROOTBALL 3"4 8. FINISH GRADE NATIVE SUBGRADE9. 9 PLANTING TABLETS - REFER TO SCHEDULE FOR QTY. OF ROOT BALLSECTION VIEW SCALE: N.T.S. R:\Consultants\Vecchio Trees\VCT1736_Logo_HighRes_Page_1.jpg PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE DANA POINT CA 92629 34197 COAST HWY SUITE 200 (949) 443-1446 SUMMERS/MURPHY & PARTNERS, INC. E N V I R O N M E N T A L D E S I G N NOTE: - "ALL IMPROVEMENTS TO BE MAINTAINED BY DEVELOPER UNTIL MAINTENANCE RESPONSIBILITY IS TURNED OVER TO INDIVIDUAL HOMEOWNER OR THE MASTER ASSOCIATION" - SOILS REPORT TO BE PROVIDED BY OWNER SMP SMP SMP PLANTING SPECIFICATIONS 177-PN PN-1 18 Refer to Hydroseed Lawn Notes for hydroseed application. rubbish, excess soil, empty plant container and trash from the site daily. All scars, ruts or other marks in the area caused by this work shall be repaired and the ground left in a neat, orderly condition. Leave site in broom-clean condition at the end of each working day. Hose down all paved areas, including walks and patios, upon completion of all work. excavated. or his representative at the end of the maintenance period. further maintenance shall occur after Final Observation with the Owner amendments. 1. Application F. Hydroseed Turf Detail Sheet for type and quality of seed mix, fertilizer and additional Hydroseed all areas designated as 'Hydroseeded Turf'. See Planting a. Equipment: Hydraulic equipment used for the application of the fertilizer, seed, and fiber pulp, shall be of the 'Super Hydro-Seeder' type as approved by the Landscape Architect. This equipment shall solids for each 100 gallons of water. The slurry distribution lines shall be large enough to prevent stoppage and shall be equipped with a set of hydraulic spray nozzles which shall place the slurry tank and spray nozzle within sufficient proximity to be seeded. than 40 lbs. of fiber mulch plus a combination of 7 lbs. fertilizer have a built-in agitator system and operating capacity sufficient to agitate, suspend, and homogeneously mix a slurry containing not less full. II. GENERAL SLOPE PLANTING 1. Slope Texturing similar mechanical means. A. Planting Preparation seed and when the tank is at least one-third filled with water. All The Owner shall have a soil analysis made after completion of rough grading. The Contractor shall incorporate all soil amendments and fertilizers prescribed herein. The soil preparation specified below shall be adjusted c. Application: Apply hydro-mulch in the form of a slurry consisting of b. Preparation: The slurry preparation shall take place at the site of at half throttle. When the water level has reached the heights of the agitator shaft, good circulation shall be established and at this time the seed shall be added. Fertilizer shall then be added, followed by three-fourths full. Spraying shall commence immediately when tank is wood cellulose fiber, seed, chemical additives, commercial fertilizer and water. When hydraulically sprayed on the soil surgace, the hydromulching shall form a blotter-like ground cover impregnated uniformly with seed and fertilizer and shall allow the absorption of moisture and rain fall and percolation to the underlying soil. Remove construction. Leave site broom-clean. shall be made by hand raking or similar mechanical means. a. Cut Slopes: These surfaces shall be roughened in a horizontal 2. Weed Eradication Procedures also roughened in a horizontal direction following the contour of the slope. The roughened texture shall be made by hand raking or fiber mulch. The fiber mulch shall be added to the mixture after the work and shall begin by adding water to the tank when the engine is accordingly to the analysis after approval from the landscape architect. a. Manually remove all existing vegetation and dispose of it off-site. fiber mulch shall be added by the time the tank is two-thirds to direction following the contour of the slope. The roughened texture b. Fill Slopes: These surfaces shall be compacted and finished and 2. Install irrigation. Johnson Grass, etc. and dispose of off site. I. GENERAL SITE PLANNING debris and litter. weed seeds. Apply water at low rate to avoid erosion. manufacturer's specifications. C. Planting size. Architect. Planting Plan and as detailed on Planting Detail sheet. 1. Ground Cover - Flats and/or Cuttings B. Soil Preparation & Finish Grading lifting plant from flat. Ground cover plants shall not allowed to dry out 4. Water all shrub/ground cover areas for three (3) weeks to germinate Plan shall remain in the flats until time of transplanting. The flat soil shall contain sufficient moisture so that soil does not fall apart when Contractor to import soil necessary to attain design grades and berms, The Owner shall have a soil analysis made after completion of the rough prescribed herein. The soil preparation specified below shall be adjusted A. Weed Control for Lawn, Shrub & Ground Cover Areas (Except Slopes) 1. Remove all existing weeds from surface. Remove all roots of Bermuda- 3. Fertilize all shrub/ground cover areas. Apply 10 lbs. of 16-20-0 commercial fertilizer per 1,000 sq. ft. or as directed by soils report. before or while being planted. Roots shall not be exposed to the air fertilizer prescribed in soils report. Thoroughly mix into soil to depth except while actually being planted. Wilted plants will not be accepted. At the time of planting, the soil around each plant shall be firmed sufficiently to force out air pockets. Plants to be planted in triangular spacing as specified O.C. (On Center). All cuttings shall be minimum of 5. Licensed applicator shall apply systemic weed killer to all planting areas per 2. Finish grade: Finish grading to consist of grading, raking and hand work all import soil shall be free of weeds, debris, and have balanced Ph. Smooth and even grading without depressions or high spots, to provide smooth and even surfaces for proper drainage. Final grade shall be 1" below walk/top of curb. Remove from the site all stones over 2" in Plant trees, shrubs and ground cover as called for where indicated on Substitutions of plants will not be accepted unless approved by Landscape upon Civil Engineer's plans, resulting in evenly finished surfaces free of 3. Spread over all lawn, shrub and ground cover areas, amendments and 1. Rough grade: Site to be received by Landscape Contractor to within grading. The Contractor shall incorporate all soil amendments and fertilizers necessary to achieve desired contour and flow line patterns, based All plant materials specified as rooted cuttings or flat stock on Planting 1/10 foot plus or minus by owner based upon Civil Engineer's grading plan. to of 6" or more and fine grade. Shape mounds as shown on plans. according to the analysis, after approval from landscape architect. 1/2" of soil surface. 3. Planting e. Allow sufficient period of time to insure that all weeds are dead. hydroseeding installation. At the same time, the soil surface should recommendations. (See Planting Detail Sheet). Add any and all soil germinate all residual weed seeds. amendments as required, per the soil analysis. Begin watering allow the soil surface to be super-saturated with water prior to the minimum of four (4) days following application of contact weed killer. f. Water all planting areas thoroughly and continuously for a period of three (3) weeks. A shorter watering period may be permissible at prior to the hydroseeding application. Care must be taken not to process to activate fertilizer and additive chemicals. c. Water all planting areas thoroughly and continuously for a period of two (2) consecutive weeks. The Landscape Architect shall approve specific watering duration and frequency program designed to d. Discontinue watering process for two (2) days, then apply recommendation by licensed applicator, if perennial weeds appear on the slopes. If annual weeds appear use straight contact herbicide as per the pest control advisor's recommendations. No water shall be applied for a the discretion of the Landscape Architect and/or the pest control advisor. Discontinue the watering process for one (1) day prior to the second application of the herbicide spraying. Re-apply the spraying operation with a straight contact weed killer, as per the days without irrigation, for effective final weed kill. g. Clear all desiccated weeds from the slopes to the finished grade. h. Water all planting areas on the regular irrigation controller schedule for three (3) consecutive days prior to the hydroseeding operation. j. Begin the hydroseeding operation in all areas, as specified. i. Then allow planting area soil surface to dry out for one (1) day only, Plant trees and shrubs as called out where indivated on Planting Plan and as detailed on Planting Detail Sheet. Substitutions of plants will not pest control advisor's recommendations. Allow a minimum of four (4) not be dry. There should be some residual moisture within the first a. Hydroseed Mix planting tablets as called for in legend. Plant all container grown plants in planting pits two (2) times wider and two (2) times deeper than the container. Thoroughly mix the specified materials found in the soil analysis and those specified in the Planting Detail Sheet, with the site 4. Planting Tablets (See Planting Detail Sheet) quantity of seed mix, fertilizer, and additional amendments. Soils Report, upon results of the soil analysis. The mix shall be 5. Hydroseeding Specifications For Slope Areas applied to all slope areas directly after the installation of all plant materials as final dressing. See Planting Detail Sheet for type and Hydroseed mix and mulch shall be amended to suit specific site conditions. Verify hydroseed mix with the Landscape Architect and soil, prior to backfilling of planting pits. be accepted unless approved in writing by Landscape Architect. Install be repaired immediately. 2. Shrub & Trees 3. Top Dressing basins shall not exceed top of root ball crown. Site Soil soil. and level as necessary to obtain true, even soil structure. Stake all trees as detailed on Planting Detail Sheet. 3. Pots and Planters - Use Kellogg's Indoor Planter MIx. 4. Staking E. Sod - See Planting Details Sheet for sod type. D. Special Backfill Mixes Architect. and all damage to sod not installed on day of delivery. penetration to at least 6" into prepared soil. sheet. Thoroughly mix 1/3 organic backfill (Nitrolized Redwood Shavings or equal) and the amendments specified in the soils analysis with the site soil, prior to backfilling of planting pits. Install Plant Tablets, per workmanship manner. All ends, joints, and cuts shall fit tightly so that there are no voids and the final appearance is one of a continuous lawn. Top dress all ground cover and shrub areas with 3" thick layer of OGC (Organic Ground Cover), to be specified on all planting plans. Contractor shall construct basins around all trees not in lawn areas; 5. Trim sod to conform to lawn shapes designated in the Planting Plan. Sections of sod less than 18" long or 9" wide shall not be used. 8. No sod area will be accepted until approved by the Landscape the manufacturer's instructions and as detailed on Planting Detail Sheet. 3. Sod shall be installed the same day it is delivered. Sod shall not be left on pallets in the hot sun. Contractor shall be responsible for any 4. Unroll sod carefully and place in staggered pattern of strips. Sod shall be installed against adjacent strips to eliminate joints and edges. 1. Azaleas - Use 80% coarse Peat Moss, and 20% clean top soil. 2. Camellias & Ferns - Use 50% Peat Moss, 25% Forest Humus and 25% Plant all container-grown plants in planting pits, two (2) times wider and each planting until one inch of water penetration is obtained. Care shall be exercised at all times to protect the plants after planting. Any 6. After sod is laid, it shall be irrigated thoroughly to provide moisture 7. All sod in sodded areas shall be handled and laid in a high standard 1. Areas shall have a smooth and continual grade between existing or fixed controls, such as: walks, curbs, catch basins. Roll, scarify, rake 2. Apply fertilizers as specified on Planting Detail Sheet and mix into the damage to plants by trampling or other operations of this contract shall two (2) times deeper than the container, as directed on Planting Detail b. Fertilize all planting areas with fertilizer based on Soil Labs 6" long. Install plants in 6" X 6" planting pits. Water immediately after G. Existing Trees A. Clean-Up C. Guarantee 3. Keep all areas weed-free, adequately watered, and neatly cultivated B. Maintenance E. Verification of Dimensions 2. After all work has been completed, inspected and accepted, all areas D. Observation guaranteed to live and grow to a period of ninety (90) days after installation and acceptance by the Owner. Trees shall be guaranteed for one year. Any material that fails to grow through the specified maintenance 4. Re-seed all bare spots in turf areas at two (2) week intervals and 8. The Contractor shall request a final site visit seven (7) days prior to the 5. Damage to any planted area shall be repaired immediately. Depressions F. Utilities and guarantee period shall be replaced by the Contractor at no cost to 1. Observation visits specified herein shall be made by the Landscape 2. Observation visits are suggested for the following parts of the work: 1. Contractor is to insure the preservation of any existing trees on the site. 6. The project shall be so cared for that a neat, clean condition will be H. See Planting Detail Sheet for additional notes. III. GENERAL NOTES All turf, hand-planted and hydroseeded ground cover, and shrubs shall be the Owner. further maintenance. promptly notify the Landscape Architect who will arrange for relocations Damage or loss of these trees will result in replacement of equal size by of one or the other. Failure to follow this procedure places upon the Contractor the responsibility for, at his own expense, making any and all repairs for damages resulting from his work. the Landscape Contractor. c. Written acceptance of the project to release the Contractor from observation at least two (2) working days in advance of the time that the b. When trees are spotted for planting, but before planting holes are discrepancy between the drawings and/or specifications and actual conditions. No work shall be done in any area where there is such a 1. The Contractor shall be responsible for verifying the location of all discrepancy until approval for same has been given by the Landscape underground utility lines prior to any construction, so that proper a. Upon completion of grading and soil conditioning prior to planting. precautions may be taken not to damage such lines and plant locations, the Contractor shall carefully check and verify all dimensions and 1. All scaled dimensions are approximate. Before proceeding with any work, quantities, and shall immediately notify the Landscape Architect of any Architect. Architect or his representative. The Contractor shall request observation is requested. 1. The Contractor shall maintain during installation a sufficient number of men and adequate equipment to perform the work herein specified. Plant maintenance work shall consist of applying water, weeding, caring of plants, including ground covers, shrubs, vines and trees, edging and mowing lawns, fertilizing, control of pests and diseases, and maintaining walks free of debris and dirt. Upon completion of each area of as is necessary to establish thriving trees, shrubs, turf, and ground cover for the ninety (90) day period. Remove all debris from site and keep the entire site broom-clean. Mow turf areas weekly. Hydroseeded turf areas shall be irrigated after the slurry mulch has been applied and maintenance representative. At this time, a list of corrections, if any, and replanted. Exterminate gophers, moles and repair damage. presented at all times to the satisfaction of the Owner and Landscape Architect. The Landscape Contractor shall be expected to make a installation, the Contractor, Landscape Architect and Owner shall allowed to set for one (1) day. The soil surface must be kept moist at conduct an inspection of completed area, along with the Owner's will be maintained for a period of ninety (90) calendar days or as long all times during the germination period to avoid desiccation of seedlings. maintain until an even stand of turf, without bare spots, is obtained. Re-seed all slope areas that fail to germinate evenly. Repair all 7. At the end of the maintenance period, all areas that have been planted shall be fertilized with commercial fertilizer, analysis and rate of end of the maintenance period. This request shall be written and directed to the Owner and the Landscape Architect. Upon written acceptance of the project, the Contractor shall be relieved of any caused by vehicles or foot traffic shall be filled with topsoil, leveled eroded surfaces at no cost to the Owner. application shall be per the soils report. minimum of one weekly visit for maintenance purposes. shall be made which are the responsibility of the Contractor. without bare spots. 1. After all installation operations have been completed, remove all 6. Application PLANNING APPROVAL ADMINISTRATIVE CASE # ____________________ EXHIBIT # ____________________ INITIAL : DATE : MUP2021-0023 03/03/22 SFE Richmond American Homes of Maryland, Inc 3191 N. Main Street, Suite 200, Corona CA. 92880 November 18, 2021 City of La Quinta Planning Department RE: Statement of Operations Model Home Complex for Bella at Piazza Serena, Tract 30092 Richmond American Homes is a homebuilder that intends to develop the remaining 60 undeveloped lots into single family residential homes in the Piazza Serena community, in the City of La Quinta. Richmond American Homes proposes to construct a model home complex for the sale and purchase of homes. 1. Description of proposed use. Response: The model home complex will be utilized to show prospective buyers the floor plans to be developed in the community. The model home complex will be for the sale of homes. 2. Hours of operation. Response: The model home complex will be open 7 days a week and will be open from the hours of 9am to 5pm. Parking will be provided and in accordance with the approved model home complex/parking lot plan. 3. Number of Employees. Response: We propose to have 2 sales agents on the property. 4. List of local/state/federal licenses/permits required. Response: Minor use permit approval from the City of La Quinta. 5. Types of equipment and processes used. Response: Model homes 6. List of any hazardous materials used/stored/produced Response: None 7. Any special characteristics specific to the proposed use Response: None other than as intended. Sincerely, Edgar Gomez Vice President of Project Management Richmond American Homes