MUP 2022-0015 Capistrano Model Home Complex Temp Generator (06.24.2022) June 24, 2022 Mr. Mario Ornelas D R Horton, America’s Builder 2280 Wardlow Circle Suite 100 Corona, CA 92880 SUBJECT: MINOR USE PERMIT 2022-0015: AMENDMENT TO MUP2021-0021 FOR TEMPORARY GENERATOR AT CAPISTRANO MODEL HOME COMPLEX AND SALES OFFICE Dear Mr. Ornelas: The City of La Quinta Design and Development Department has reviewed and approved Minor Use Permit (MUP) 2022-0015, an amendment to MUP2021-0021, for a temporary generator to power the sales office and model home complex within the Capistrano development, subject to the information on file and attached and the following findings and conditions of approval. The approval of this Minor Use Permit amendment does not extend the operational time limit of two (2) years as set forth in MUP2021-0021. FINDINGS • The proposal is consistent with the general plan and provisions of the zoning code. The proposal is in compliance with the requirements of the California Environmental Quality Act (CEQA) and would be exempt from CEQA pursuant to Section 15304, Minor Alterations to Land. • The proposal would not create conditions materially detrimental to the public health, safety and general welfare or injurious to or incompatible with other properties or land uses in the vicinity. • The proposed use of the generator is temporary in nature and would be placed in an area consistent with ground mounted equipment in residential areas. The generator is located approximately 150 ft away from the nearest residence and is estimated to generate noise levels under the exterior noise level limits in the Noise section of the zoning code. CONDITIONS OF APPROVAL: 1. The applicant agrees to defend, indemnify and hold harmless the City of La Quinta (“City”), its agents, officers and employees from any claim, action or proceeding to attack, set aside, void, or annul the approval of this Minor Use Permit amendment. The City shall have sole discretion in selecting its defense counsel. The City shall promptly notify the applicant of any claim, action or proceeding and shall cooperate fully in the defense. 2. Minor Use Permit 2022-0015 shall comply with all applicable conditions and/or mitigation measures for the following related approval: Minor Use Permit 2021-0021 In the event of any conflict(s) between approval conditions and/or provisions of these approvals, the Design and Development Director shall adjudicate the conflict by determining the precedence. 3. The temporary generator may be used until Imperial Irrigation District provides power to the site or up to 60 days, whichever comes first. The generator must be removed within 7 days of either occurrence. The City may elect to add Conditions to this application request to mitigate any problems that arise not previously addressed herein. This decision may be appealed to the Planning Commission by any party who submits the necessary paperwork and filing fee of $1,526.00 to this office within 15 days of the date of approval of this permit. If you have any questions, please contact me at (760) 777-7067. Sincerely, Cheri Flores Planning Manager Design and Development Department D.R. HORTON • EXPRESS • EMERALD • FREEDOM 2280 Wardlow Circle, Suite 100 • Corona, CA 92880 • O 951.272.9000 • www.drhorton.com     June 21, 2022 Siji Fernandez City of La Quinta Design and Development Department 78495 Calle Tampico La Quinta, CA 92253 RE: TR 31910 – Capistrano – MUP2021-0021 Amendment – Statement of Operations for Temporary Generator Mr. Fernandez, The proposed temporary generator will be strictly used to power the sales office, the overhead lighting and air conditioning. We are estimating to use it for about 30 days until IID provides power. Please let me know if you have any questions. Regards,       Mario Ornelas Project Manager D.R. HORTON 2280 Wardlow Circle, Ste. 100, Corona, CA 92880 o: 951.739.5481 m: 951.415-4568 e-mail: maornelas@drhorton.com   1210 N. Red Gum St. Anaheim, CA 92806 To Whom It May Concern; In regards to the 56KW generator feeding the “Single Family” model building/sales office at the DR Horton “The Enclave at Capistrano” site (tract # 31910) for the grand opening; at the closest existing residence which is approx. 150’ away; the generator has a DBA level of 51.71. With the DR Horton installing a vinyl fencing enclosure, and perimeter walls in between the generator and the closest residence, the projected DBA level will be 43.7. If you have any questions or concerns with this; please contact John Little at Power Plus. John Little Power Plus 951.722.6736 jlittle@powerplus.com DCA70SSIU4F — MQ POWER SERIES GENERATOR — REV. #9 (06/01/22) DCA70SSIU4F Generator WhisperWatt™ Prime Rating — 56 kW (70 kVA) Standby Rating — 62 kW (77 kVA) 3-Phase, 60 Hertz, 0.8 PF 70 „Heavy duty, 4-cycle, direct injection, heated crankcase vent, turbocharged, charge air cooled, 1000W block heater, diesel engine provides maximum reliability. „EPA emissions certified - Tier 4 Final emissions compliant. „Microprocessor engine control system maintains frequency to ±0.25%. „Fuel/water separator removes condensation from fuel for extended engine life. Panel-mounted alarm light included. „Sound attenuated, weather resistant, steel housing provides operation at 65 dB(A) at 23 feet. Fully lockable enclosure allows safe unattended operation. „E-coat and powder coat paint provide durability and weather protection. „Internal fuel tank with direct reading fuel gauge. „Spill containment - Bunded design protects environment by capturing up to 128% of engine fluids. „Brushless alternator reduces service and maintenance requirements and meets temperature rise standards for Class H insulation systems. • Open delta alternator design provides virtually unlimited excitation for maximum motor starting capability. • Automatic voltage regulator (AVR) provides precise regulation. „Fully covered power panel. Three-phase terminals and single phase receptacles allow fast and convenient hookup for most applications including temporary power boxes, tools and lighting equipment. All are NEMA standard. „ECU845 microprocessor-based digital generator controller. • Remote 2-wire start/stop control. • High visibility LCD display with heated screen and alphanumeric readout. • Operational temperature range of -40° to 85° C. • AC monitoring along with fuel and DEF level indicators. „Digital engine gauges including oil pressure, water temperature, battery volts, engine speed, fuel level and DEF level. „Analog generator instrumentation including AC ammeter, AC voltmeter, frequency meter, ammeter phase selector switch, voltmeter phase selector switch, and voltage regulator adjustment potentiometer. „Automatic safety shutdown system monitors the water temperature, low coolant, engine oil pressure, overspeed, and overcrank. Warning lights indicate abnormal conditions. „Voltage selector switch offers the operator a wide range of voltages that are manually selectable. Fine tuning of the output voltage can be accomplished by adjusting the voltage regulator control knob to obtain the desired voltage. „Emergency Stop Switch — when manually activated, shuts down generator in the event of an emergency. STANDARD FEATURES DCA70SSIU4F — MQ POWER SERIES GENERATOR — REV. #9 (06/01/22) DCA70SSIU4F Generator SPECIFICATIONS Generator Specifications Design Revolving field, self-ventilated Drip-proof, single bearing Armature Connection Star with Neutral Zig Zag Phase 3 Single Standby Output 62 KW (77 KVA)44 KW Prime Output 56 KW (70 KVA)40 KW 3Ø Voltage (L-L/L-N) Voltage Selector Switch at 3Ø 240/139 208Y/120, 220Y/127, 240Y/139 N/A 3Ø Voltage (L-L/L-N) Voltage Selector Switch at 3Ø 480/277 416Y/240, 440Y/254, 480Y/277 N/A 1Ø Voltage (L-L/L-N) (Voltage Selector Switch at 1Ø 240/120)N/A 240/120 Power Factor 0.8 1.0 Voltage Regulation (No load to full load)±0.5% Generator RPM 1800 Frequency 60 Hz Winding Pitch 2/3 No. of Poles 4 Excitation Brushless with AVR Frequency Regulation: No Load to Full Load Isochronous under varying loads from no load to 100% rated load Frequency Regulation: Steady State ±0.25% of mean value for constant loads from no load to full load. Insulation Class H Sound Level dB(A) Full load at 23 feet 65 Engine Specifications Make / Model Isuzu / BR-4JJ1X Emissions EPA Tier 4 Final Certified Starting System Electric Design 4-cycle, water cooled, direct injection, turbocharged, charge air cooled, DOC and SCR Displacement 183.0 in3 (2999 cc) No. cylinders 4 Bore x Stroke (mm)95.4 x 104.9 Gross Engine Power Output 95.2 hp (71 kW) BMEP 208 psi (1434 kPa) Piston Speed 1237 ft./min. (6.29 m/s) Compression Ratio 16.5:1 Engine Speed 1800 rpm Overspeed Limit 2070 rpm Oil Capacity 3.96 gallons (15 liters) Battery 12V 75Ah x 1 Fuel System Recommended Fuel ASTM-D975-No.1 & No.2-D* Maximum Fuel Flow (per hour)16 gallons (60 liters) Maximum Inlet Restriction (Hg)2.9 in. (73.6 mm) Fuel Tank Capacity 103 gallons (390 liters) Fuel Consumption gph lph At full load 4.4 16.6 At 3/4 load 3.5 13.4 At 1/2 load 2.6 9.8 At 1/4 load 1.7 6.4 DEF Tank Capacity 7.4 gallons (28 liters) * - Use ultra-low sulfur diesel fuel. Cooling System Fan Load 4.7 hp (3.5 kW) Coolant Capacity (with radiator)5.5 gallons (21 liters) Coolant Flow Rate (per minute)15.9 gallons (60 liters) Heat Rejection to Coolant (per minute)2483 Btu (2.62 MJ) Maximum Coolant Friction Head 1.2 psi (7.9 kPa) Maximum Coolant Static Head 3.3 feet (1.0 meter) Ambient Temperature Rating 104°F (40°C) Air Combustion Air 138 cfm (3.9 m3/min) Maximum Air Cleaner Restriction 25 in. H2O (6.25 kPa) Alternator Cooling Air 526 cfm (14.9 m3/min) Radiator Cooling Air 3700 cfm (105 m3/min) Minimum Air Opening to Room 6.03 ft2 (0.56 m2) Minimum Discharge Opening 3.33 ft2 (0.31 m2) Exhaust System Gas Flow (full load)272 cfm (7.7 m3/min) Gas Temperature 572°F (300°C) Maximum Back Pressure 7.2 in. H2O (17.5 kPa) Amperage Rated Voltage Maximum Amps 1Ø 120 Volt 155.4 Amps (4 wire) 168A x 2 (Zigzag) 1Ø 240 Volt 77.8 Amps (4 wire) 168A (Zigzag) 3Ø 240 Volt 168 Amps 3Ø 480 Volt 84 Amps Main Line Circuit Breaker Rating 200 Amps Over Current Relay Trip Set Point 480V Mode Only 84 Amps WARRANTY* Isuzu Engine** 12 months from date of purchase with unlimited hours or 36 months from date of purchase with 3,000 hours (whichever occurs first). Generator 24 months from date of purchase or 2,000 hours (whichever occurs first). Trailer 12 months excluding normal wear items. *Refer to the express written, one-year limited warranty sheet for additional information. **Refer to Isuzu Diesel Engine Limited Warranty for details. NOTICE Specifications sheet is subject to change and is not intended for use in installation design. DCA70SSIU4F — MQ POWER SERIES GENERATOR — REV. #9 (06/01/22) DCA70SSIU4F Generator GENERATOR OUTPUT PANEL Our soundproof housing allows substantially lower operating noise levels than competitive designs. WhisperWatts are at home on construction sites, in residential neighborhoods, and at hospitals —just about anywhere. 70 60 90 80 50 Subway / truck traffic Average city traffic Inside car at 60 mph Air conditioner at 20 feet Normal conversation WhisperWatt at 23 feet 65.0 DECIBELS MQ POWER DECIBEL LEVELSMQ POWER DECIBEL LEVELS CS-6369 TWIST-LOCK RECEPTACLES (3) 240V/120V, 50 AMPS GFCI RECEPTACLES (2) 120V, 20 AMP CIRCUIT BREAKERS FOR GFCI RECEPTACLES CIRCUIT BREAKERS FOR CS-6369 TWIST LOCK RECEPTACLES OPTIONAL GENERATOR FEATURES „PowerBalance™ — designed to assist generators when operating under low temperature and/or low load conditions to insure peak performance. „Battery Charger — provides fully automatic and self- adjusting charging to the generator's battery system. „Trailer Mounted Package — meets National Highway Traffic Safety Administration (NHTSA) regulations. Trailer is equipped with electronic or surge brakes with double axle configuration. OPTIONAL CONTROL FEATURES „Audible Alarm — alerts operator of abnormal conditions. OPTIONAL FUEL CELL FEATURES „Sub-base Fuel Cells (double wall) — additional fuel cell for extended runtime operation. Contains a leak sensor, low fuel level switch, and a secondary containment tank. UL142 listed. „12 hours of minimum run time. „24 hours of minimum run time. OPTIONAL OUTPUT CONNECTIONS „Cam-Lok Connectors — provides quick disconnect alternative to bolt-on connectors. „Pin and Sleeve Connectors — provides industry standard connectors for all voltage requirements. „Output Cable — Available in any custom length and size configuration. © COPYRIGHT 2022 MULTIQUIP INC. DCA70SSIU4F Rev. #9 (06/01/22) DCA70SSIU4F Generator MULTIQUIP 6141 Katella Avenue Suite 200 Cypress, CA 90630 310-537-3700 E-MAIL: mq@multiquip.com WEBSITE: www.multiquip.com SKID-MOUNT DIMENSIONS 34.63 in (880 mm) 41.50 in (950 mm) 68.31 in (1735 mm) 105.12 in (2670 mm) 20.08 in(510 mm) 70 19.69 in(500 mm)22.44 in(570 mm) 19.69 in(500 mm)23.23 in(590 mm) 57.68 in(1465 mm) 25.39 in (645 mm) 85.12 in (2162 mm) 96.57 in (2453 mm) 71.50 in (1816 mm) 70 165.26 in (4197 mm) 11.46 in (291 mm) Shown with optional TRLR70USH, PowerBalance™ Stabilizer Jacks, Tool Box, and Spare Tire Generator can be placed on MQ Trailer Models TRLR70US and TRLR125XF2. DCA70SSIU4F Weights* Dry Weight 3,326 lbs. (1,509 kg) Wet Weight 4,207 lbs. (1,908 kg) Max. Lifting Point Capacity 6,960 lb. (3,157 kg) * Weights do not include options. NOTICE Features and Specifications are subject to change without notice. DCA70SSIU4F and TRLR70US Weights* Dry Weight (with TRLR75XF2)4,415 lbs. (2,003 kg) Wet Weight (with TRLR75XF2)5,296 lbs. (2,402 kg) TRAILER-MOUNT DIMENSIONS