Loading...
FSS2018-0055ADDITIONAL SITES CHRONOLOGY CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT RESIDENTIAL FIRE SYSTEMS INC / EDGAR VELASCO 8085 E CRYSTAL DRIVE ANAHEIM CA 92807 EDGARV@REFIRE.COM BILL TO RESIDENTIAL FIRE SYSTEMS INC / EDGAR VELASCO 8085 E CRYSTAL DRIVE ANAHEIM CA 92807 EDGARV@REFIRE.COM CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL ARMANDO MAGALLON 4/19/2018 4/19/2018 APPLICANT E-MAILED SLIP OVER TO ME AND ASKED IF I COULD MAIL PACKAGE WITH PLANS. I PUT PLANS OVER BY CONCIERGE AND LEFT A VOICEMAIL FOR APPLICANT LETTING HIM KNOW TO SCHEDULE A PICKUP TIME FOR THE PLANS. TELEPHONE CALL AARON HICKSON 4/18/2018 4/18/2018 RESIDENTIAL FIRE WILL SEND A SHIPPING LABEL FOR APPROVED PLANS. CONDITIONS Description: HICKS / RESIDENTIAL FIRE SPRINKLER Type: FIRE SPRINKLER Subtype: RESIDENTIAL - CUSTOM HOMES Status: FINALED Applied: 3/30/2018 AHI Parcel No: 777390002 Site Address: 80957 VIA PESSARO LA QUINTA,CA 92253 Approved: 4/4/2018 RGR Subdivision: TR 29894-3 Block: Lot: 40 Issued: 4/19/2018 AMA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 7/30/2018 EGO Valuation: $0.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: Printed: Thursday, July 07, 2022 10:15:13 AM 1 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0055 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR RESIDENTIAL FIRE SYSTEMS INC / EDGAR VELASCO 8085 E CRYSTAL DRIVE ANAHEIM CA 92807 EDGARV@REFIRE.COM OWNER BRENT & JORJA HICKS 5525 SE SCENIC LN #200 VANCOUVER WA 98661 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FIRE FINAL**EGO OVERHEAD ROUGH PIPING EGO 7/24/2018 7/24/2018 NOT READY FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED 101-0000-42421 0 $156.00 $156.00 3/30/18 R33638 105980 CHECK RESIDENTIAL FIRE SYSTEMS INC /AHI FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC 101-0000-42420 0 $234.00 $234.00 3/30/18 R33638 105980 CHECK RESIDENTIAL FIRE SYSTEMS INC /AHI Total Paid for FIRE FEES: $390.00 $390.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 3/30/18 R33638 105980 CHECK RESIDENTIAL FIRE SYSTEMS INC /AHI Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 3/30/18 R33638 105980 CHECK RESIDENTIAL FIRE SYSTEMS INC /AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$405.00 $405.00 Printed: Thursday, July 07, 2022 10:15:13 AM 2 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0055 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/30/2022 JOSE DELGADO Fire Review Application.pdf Fire Review Application.pdf 0 DOC 6/30/2022 JOSE DELGADO FSS2018-0055 - 80957 Via Pressaro.pdf FSS2018-0055 - 80957 Via Pressaro.pdf 0 DOC 6/30/2022 JOSE DELGADO FSS2018-0055 Inspection Log.pdf FSS2018-0055 Inspection Log.pdf 0 DOC 6/30/2022 JOSE DELGADO Hydraulic Calculations - 1 HD Casita Bedroom.pdf Hydraulic Calculations - 1 HD Casita Bedroom.pdf 0 DOC 6/30/2022 JOSE DELGADO Hydraulic Calculations - 2 HD Casita Bedroom.pdf Hydraulic Calculations - 2 HD Casita Bedroom.pdf 0 BOND INFORMATION OVERHEAD HYRO FRE 7/24/2018 7/25/2018 NOT READY FIRE FINAL**EGO 7/30/2018 7/30/2018 APPROVED OVERHEAD ROUGH PIPING EGO 7/30/2018 7/30/2018 APPROVED W/EXCEPTIO N Needs job card on next inspection. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) AARON HICKSON 3/30/2018 4/2/2018 4/4/2018 COMPLETE 1ST FIRE (2 WK)RONALD GRIESINGER 3/30/2018 4/13/2018 4/4/2018 APPROVED PARENT PROJECTS Printed: Thursday, July 07, 2022 10:15:13 AM 3 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0055 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/30/2022 JOSE DELGADO Residential Automatic Sprinklers Model GL4110 _ GL4910.pdf Residential Automatic Sprinklers Model GL4110 _ GL4910.pdf 0 Printed: Thursday, July 07, 2022 10:15:13 AM 4 of 4 Permit Details City of La Quinta PERMIT NUMBER FSS2018-0055 GENERAL NOTES - AFFA 13 , t A CITDMAi TEVC PRE SPf &ViKLER 3?'S7'EAd HAS BEEN L aIFaA ED TO GE INSTALLED IN ACCORDANCE W1774 NFPA 13D. CRC 2016 EDfTAION AND AUTHORITY HA Mr;? JUW0JCT70N GODEL&ES 2 Tl-f1S SPRAKLER SYSTEM SHALL BE TESTM AND ffW3PE=D 907H THE RC3UGH AND F AL. MPEC77ON FiROR TO OCCUPAWYBEINO GRAMED- 7T E,JVRSDICT+�CNAL FhGE PRffYEN770N OFFICE WILL BENOTPED A M+4w19'N M CDF TWO WORKANG DAYS IN ADVANCE OF 7HE AIEGUEST D 11i EpE 770N 3 THE PZT.A LLER SHALL PERFORM ALL REOUfRED ACCEPTANCE TEST COMPLETE THE CONTRACTORS MA TEMALS AND TEST CERT)RCA 7F AND FORWARD 'rD 7) IF AUTH0P{TY HAV M XR18D4CRON PRO R TO ASKAr-. FOR 9NAL APPROVAL OF THE dfZTALLY TKXV NOTCHING DMLLdNQ 09 07HER WISE REFAIETRA77NG 9T7RLACTURAL MEMBEnS SHALL BE INACGOR'DAMCE THE ALh'"-0RA#A eUrr DIAU coDE 5 TYPE OF PIPE SHALL BE UL. LfSTErQ CPVC PIPE CCPP,6R TYPE M OR 67IEEEL PFE SEF RISER ❑FTAfL AND FIRE SPRMLER PLANS- CPVC PFE SH ALL BE INSTALLED PER MAiNL1FACTL49ER S MTALLATION INS THIJICTIONS. 6. A StPPL Y OF SPARE SF'RiWLETS G)4A2 L 9E PRoVrEDED PEn 7HE REOL f EMENTS ,SET FORTH 1N NFPA 0 SEC DON 629 ANDIOR AS REOUPED BY THE A UMORI7Y HA IfM )UR SDIC TICK) 7. ALL VA VES SHALL HA VE A Pf•RMAAENTL Y AFFIXED SIGN WDICA TAU fFS R1NC 77[ N 8. PA"E SHALL SE HUNG FROM 5TiRUC77RAL MRAgFR6 PER THE MFPA 13D GUIDELNES. PIPE CLAAMS AAD SCREWS .SNAG BE UL LISTED AND INCMTALLED N ACCORDAIVC}F WfTH 7W INSTALLA 77OiV GLIIDEL&rS 9 THE SFA,CAG AND LOCATM OF SPMNKLERS ,SHALL CONFOW WITH THE MANUFACTURP REOiMEMENTS AND THOSE CONTAINED NV NFPA 13D, CFTC, Xf6 EDrWN 10 THE ALARM ADCCA 77NU DEIIIC& SHALL OE LISTED FOR OUTSIDE SERVICE AMD BE A UDOLE FROM THE STREET THAT ThdE HOLSE A5 ADDRE6SED ON. ALAHW SHALL BE OF a#=FCENT WTEASITY, CLEAfRL Y ALAnOLE #V 4LL ROOMS R17H INTERVENVVG DOORS CLOSED. 11 SMOKE DOCTORS TO BE 1NSTALLELD 3r 077- ERS 12. RESIDENTIAL CONCEALED ORTJINARY TEMPERA TURF SPR#WLERS ARE 1l L. LISTED, SEE PLANS FOR N3TALLA 77ON SPACM X3 RESIDENTIAL PEf AIT) LATER tCDL4 TE TEMPERA TUhRE ,SPRINKLERS ARE U.L. LISTED, SEE PLANS FOR INSTALLA T7010 SPACfA . 14. OVCK RESPONSE UPRIGHT iYTERMEDIA TE TEMPERA TUBE SPiRAKLEPS AAE UL. LISTED AND SHALL SE WSTALLED A T A T77C FUEL FIRED F A U. 15 A 200 PSI PRESSURE HYDRO- TEST IS RECUIREED AT ROUGM (NS'PEGTi0N. f6 FRE,STOPPING RE X*%-WNT; PEAEMA TENS 7HRU RA TED WALLS AND FWOP9 ,cO bALL BE SEALED W1 A MA7SUL CAPABLE OFPFEW-NTING ThE PASSAGE OF FLAWS AND HOT OASSES WHEN SL9kjEC7FD M 77-iIE REObP EVENTS OF TIE ?EST STANDARD SPEC4F1C FOR THE FOE STOPS A.S.T -E-84 (BY OTf-EAS) RISER L ATK)N -a RATED WALL DETAIL GARAG EIDWELLI NG GAIRAGFJDVVE LLI NG COMMON WALL TYP. COMMON TYP -WALL GYP_ EOARQ LINED GYP, BOARD BT N. JOIST BAY, EQUAL FURIRM WALL _ TO RATED WALL_ u I �f I ' I 24 1 4-VT rPANEL FIRE SPRINKLER RISER INKLER RISER I INTE RIOR ACCESS IOR ACCESS PANEL (14-112"x24") TYR 4-1f2"x24") TYP. w/lN i0m BAY ALT, WAN FURRED V1+ALL - AFIRE CAULKING NOT REQ'D) DRAIN LINE TO EXT. OR DRAIN (IF APPLICABLE' WI RELIEF VALVE) WAN .JOIST 4AY ONLY; GYP. BOARD LINED JOIST SAY, EQUAL TO (RATED WALL W JQW A}IY ONLY FIRE CAULK ALL JOIST BAY PENETRA-HON5, EQUAL TO RATED WALL l F 4-11i"F ANT 14EW AUXLWW DL, I - UL FROM FIRE SPRINKLER AUXILIARY DRAIN SIGN 112" KEYLESS HOSE SIB I C. P Y,C. PIPE DIhASENSIONS SDR I.7.5 (A87V F W2) fffVCf`AE31 NOMI AL CUTSDE 51DE TUBE + WATM SIZE DIAMETER DIAMETER LBS.IFT_ 314' #.0a0 U74 0.168 1' 1315 t66i] 1,1D1 C.262 DA18 111 ' 1 394 1-•1/27 1.800 �998 0 2' 2,376 2.003 0250 ZE?75 2.423 1257 3, 2.951 1,867 COPf"En 7UBE TYPES L AND M PIPE DfMEN,SIOAIS - - (INCHES) NDI MAL OUTSIDE NSIDE VIES + WATER SIZE DIAMETER DJAMETER L.Bs-IFT. TYPE: L m L M L m 3/4` C175 0.875 0,785 on _ 0.664 D.551 1' t125 1.125 1.025 W55 1.01 RBQ 1-414' 1375 L375 i825 W26 Ll:h5s U91 1.43 125 t91 L73 1y1j2' 1EC6 1.527 2 226 2125 12M 20m &09 2W 2-iV2'—1 2625 Z625 2.465 P-495 454 4,14 FIM DER SPACH4 e TABLE (PER NFPA 131 MAXIIAL A DISTANCE BETWEEN HANCEM PIFE� STEEL rE EXCE r LCHVA11 N/Ams'-IT 1 -f� f � f-f22'2-112-1 r� �y� 3' �rM 15� ' 12'-C 12'�' �i � N/A -v NIA 5'NOMNAL {i�[ NIA 6-' WA i�MEADETB-v' N/A ,STEEL PIPE _ THREADED LIL'f17WAI1 COPPER TUBE CpvC MULE FM PIPE � jA F-T S-q IZ-V IZ-V 17-Cr 94 cl-0' "I W-V 12'-0 12'-V 15'-0' 16-0' 15'-01 A NIA 154 I fA ' U-T 16'-0' 5'-6' I� A P'-0' WA v-' A T Ai ,4 w-5, MIA To- A icFr 15' 4` N A N{,q NIA 15-D' N A 14 PER AFPA W 20I6 EDI77ON 331 - COMPAfR VENT A SPACE COMPLE7L Y ENCLO BY WALLS AW CELMW EACH WA,(L N THE COMPAR TMI-NT S PE# Tr,l='U 70 HA VE OPEWW TO AN AD,.i1DINAG SPACE F THE OF -Er HAVE A AMW L.ATEL ❑EP7H OF B d'J FROM Ti E CEILAU AND THE TOTAL WDThf OF TL E OPEMh A35 N A SAC LE WALL ODES NUT EXCEED 8 FT fN WV7H A 8GVCLE CPSWVG OF 36 dN OR LESS fN WV TH WlTh OUT AI LNTEL IS PEFTUTFED lff+ N TfCmCLA;7 ARE NO OTFER OPE OIG S TO ADJOYQ G SPACES. 9-27 CLCXSFTS WALL CLOSETS AAC COWA 19TMEAFF& HdCL-I)L O W5EHOIUHAU MECI-L41�CAL. E'OWMENY rHAT ARE SMALLER THAN 400 M M9BENT, UPRGL(T AND SCEWALL RESEENTIAL SPRJPVKLEW"LL $F A5R+IC ED TO BE A6TALLED AV &hLA=#I OF T LLOW G STTUA TUW M W7W 18 IN OF T CE LW TO AV60 OB6R tJCTDA S AEA q 7HE CsLw (2) AT THE F#aLEST CEUM LEVEL WITF� REGARD TO OGSTRUC77OAS OR 001fla6lA D197 ANCES TO WALL 8.2566 SHADOW AAEA3 SMALL BE PER1 77ED IN THE PRD FCTK-W AREA OF A SPR#4B4v LiER AS LONG AS THE Gf MaA TI6E DRY AREA S DO NOT EXCEED 15 SOFT PER 6rAwKL M $32 ERAWLERS 54MLL N;OTRE RED RA7NRODW UN057 55 SO?7 AND LESS 8.33 5Fi4 LEA SHALL NOT LEIEOL AEICL07HES CI.OSET.SLI" CLOSETS, AND PAMME'S THATA=Af.L OF THE RXL0Ib 6- CQAhCW7rON5 1 7ilF AREA OF THE SPACE DOE£ WT EXCEED 24 SOFT 2 T7-EE WALLS AAC L#VaS ARE S&RFACIED WM) N0AC0M9U6T0LE OR LA#7ED-COQ6{86S7 BLE MATERt4L,S AS CETAW NV AFPA R20. 8340 SPRNKLERS 5NA LL NOT SE REEOURED N DETACHED C4 RAC3ES� OPFN A TTA CY ED POI ChE CARPORTS AND SWL<1R SMVC7Z#FS 535 SPRAKLERS SHALL NOT BE REOLOYD N ATTrS W7H OR WI7}1C7UT,STORAGE PEXYHaYWEOLIrWNTRQOM3, ELEVATOR MAChWYEROOW CONGEALED SPACES DE=A TED EXCLUS'WL Y 7U A AD CONTAiF`f9 V G L Y DAELLAU WT VENTLA TION EGUFWNT FL OORIC.EdL,NV4G SPACES EL EVA TOR SHAFTS CR4 W- SPACES' AAD0THERCC%C`.FTIALED SPACES ArAfEN0T! DCRNT D FOR LI UG SPACES 83.5.1 & CH 5FACE9 THAT CCNTAhV FLn-FRED EOY#MNT ,SHALL ALSO COMPL Y w9H 8.,3511 OR 83 u 912511 *EF1E 7-E FL EL-RRED FCUdFII+THVT S ASUVF ALL Oc THE DCC.LFE-D AREAS OF .r�� THE DWELL AG iW SPRfl4KLEfR PROTFCDON SHALL BE RE00FED 8,0.,512 W -EFEF FUEL-•FNF-D EQU#WS T AS BELOW OR CN T�E SAME LEVSL A5 OMP ED AREAS OF 7HE D WELL &V4Q A T LEAST ONE CK-RESP4CAGE 1WE DfA7E TBRF'ERA Tu9E SPRA1jKLER SHALL BE hSTALLED AGO7NE EgA%ENT OR AT THE WALL SEPARATM THE SPACE 1' nH WTrH ThE FtEL-FOED ECURENT FROM THE OCCUPED SPACE 836 SPRWI 5 SL64L L NOT BE R OLO' EV W CCTV LA4W4 TEO PfROJEfC5ONS OF THE BULDW A T ENTHA CESIEWTS AS LONQ A5 THE DWELL W WT HAS ANOTHER MEANS OF rE SS. &3.8 5i9WLE 57Yr#LL NOT&E RFOURED iW CLOGEM IN GARAaES ANO EXTENOR CLOSETS (REa4f7DLE66 OF SEED LOCATED ON EX72ROR a4LCOWS FXMNOR DREEIEWAM/CaRWORS OR ACCESSED MW 9MOOMWHMFTMf 7 CLOkSEfDOES NOT HAVEpQQRSORiOtiG W7ECTEL7LL PEhMA TkW OhrECTLT A TO 77-IE DWFLI,AVG 4A T A7-nC PIKE STRAP/RAIN OVER DETAIL — SLOPE: 113 'RCXKsr— SEE NOTES TE �.nnir g OR - UPRIGHT, PARALLEL WI ROOF (IF APPLICABLE) BRANCH LINE UPRIGHT SPRIG -LIP �ti 't 6" MAX MAIN LINE � WOOD TRUSS HANGER OR JOIST 112" OR 318" OYP. BOARD TYP. LFIRL SPRINKLER TJI) OR JUST PIKE HANQERIARM OVER DETAIL - INIMPEMIAL SPACE I TJI i JOIST I ` I TJI FLOOR FRAMING 2N-WOOD BLOCK TYP- JOIST FLOOR FRAMING SCREW 6" MAX- Wf BACKING NUT TYP. SCREW J f FAAIfVLINETYP PIPE HANGER TYP. r I FIRE 112" OR 3M" GYP. BRANCH LINE TYP. SPRINKLER BOARD TYP E4 SOFFIT PPE HANGER DETAIL WOOD JOIST Ll112" MAX- iv ALTMIAM G T20 SAf4 MY SCREW (PRE --DRILL @ RAID. OF BM.) NOTE=: GST20 SAMMY SCREW MUST EXTEND MINIMUM 3110" ABV. TOP OF BOT. FLANGE 2" MAX. FIRE SPRINKLER PIPE CPVC, COPPER, OR STEEL (SEE PLANS) RING'HAN('i R TJI m JMAXIMUM RANGER SPACING PER NFPA 13 (SEE PLANS) ROD J- PPE HANGER DETAIL PIPE SIDE INSTALLATION NOT TO S A, F SEE BELOW. ' MOUNTING POSITION -TOP, BOTTOM OR 8IIDE U.N.0, " 114' tEK TYPE SCEWS PROVIDED. TEKTYPE SCREWSTYP. 314" THRU F P1PE_f OFFSET HANGER TYP. )DOUBLE 31A" THRU 2" PIECE FASTNER STRAP TYP. SIDE MOUNTED DOUBLE FASTENER STRAP TYR 3f4" 7HIRU 2" PIPE - �` r J� + rs frfF f� N jf fir fIs , Yr+r f irf "MOUNTINO POSITION - TOP & BOTTOM 111 R. CARiREO D z 0 ° < ¢ AVE 48 O Z) W s w [} J AVE 5 D > O A E61 92 O AVE 52 AVE 53 AVE 54 NORTH Y` '. Au-nON 7]'r1R i CWA#E A Cfl iV SPRwnFASY5'TEM MV CPIV ,--RE SCR SYSTEEI2 A LFF B'AFS7 rdSS&&YADAawrsEiRFAT£DCAREFULLY.NEASE#EAV IhE FOLLOW fficoREAYACP7M*CH CC .D CONTACT THS SM7EY CMG PPAh42 COMWENT9 MA YBEEMMO D BY CERTAW SVa1 TAACES IM CO►LSTFWMVPRAC7CES DO MOT STD. a S{APPORT ht,4A ` E `+DY+iEVT OAR HANG FL&&E WFICAOLE e;PECAU E' CO "WA TIC3'S CASW, OR ON R MA MB AL ON P-E F39E SP CtB4 2YS01- * OIL Y SNTR3 C-IWA 7MILE l A TERALS j Va6Ep W SUF ACT L.&kFI D TO SCL VBVT C&AW7r� C, UjUi SUALAN76 C.I1TW. 6 AAD 7#]IcAD PASTES AS A'fOTED bYM4+VWAiC:1h' S ASTALLATIOV 7RUC7101ti1S Sfx= mrwxm by CONTACT WTTH TH6 SYSTEM • DO NDF EAF0 F `PVC PRCPLWT5 TO A CGWA TELE SLWTAACE6 R CH AS C67LV-S, NON -WA TPA 44SEDPA FA CFI M6$ 7h4gTIO}1i+ML PFETHREAD PA97EAND DOPE RA'4U1CdDM T€%=L-.7 d'qL F'71aW DES RX0#V0 C.AL. X6 A E TAPE S XDER FLUX R-jFX6LF W#EICAa-E Wh PEDAL CONkERA7IIONFOR COA494fI1!l4rC.AI7O&5 CA9L+W), 4W NCWAPPROVE-D SPRArF04M 96aA n0N MATFfNAL6 DD NOT EXP 0 FWaCrS TO ED RE OILS 510E VENT& OR CL YC(X 4ALb7-D .uAri7� Flt09 a 00 NOT EXPORT CPVC SIG TS TO CPF+V FLAME &9-DE-j AAV SOLDaW FLUX ■ DO 1VT DROP, RETORT, CRJWACTCFVC PROCW76` C R ALLOW OBL E'C7E TO SE DRaPPM ON ]lam • DONOF HAAt XE CPVC PRODUCTS WTH GLOWS CCMITAAM TED 14@TH L (HYMXARB0A15) OR OMER =',i rA TIBLE MA TERM LS FAI ur 7z) FaL ow rNs tVL wE YA rcAb5r CAACKS a? Fm=w To cp #v Cf°VG' P+ROOLICTS RESM TM NPROPSRTYDAAMCE AAV FBVS(W4A nMYDLE TO LEAKS OR FLWM f7EPHaSCZ OF ANY 1 9E CR40KS VAYInXhU PAR77AL OR FALL SY67EMRE ACE ADOfftWAL AFOFWTXW CCWTACT ? J E C,EA ENL C:OMMAO" T'E FNE ,5FWLi"R S YSiEhd rp6TA LLER OR TIE CPVC AM AC Tf,0�ER Arn PIKE P TE-I f I UL.ATX)N TENMNQ CUFAIL - - (BY OTHERS) PIPE ON BOT. CHORD OF ROOF TIRU,5S UNDER GATT INSULATION WAN ATTIC TYR (BY OTHERS) . IA ' r PIPE TYR, 2 f HATE CEILING INSULA-noN {IYP.) SPRINKLER BELOW 318" GYP, BOARD } OR 7I2" PLYWOOD BATT INSULATION (TYP.) PIPE ON ROT. CHORD OF ROOF TRUSS UNDER BATT INSULATION WnN ATTIC TYP. (BY OTHERS) 12" 1411N. 9 2" M IAT_ ATTIC 316" GYP. BOARD CEILING INTERIOR OR lf2" PLYWOOD SPRINKLER SPACE na .r PLAN NED BY, E SI ENGINEERING 77-540 SYFIWOFfELD L.AA,EL STE 'C' PALM DESEf9T, CA 92.2fT PHONE: 760-772-8400 CONTACT - FHE HSE II LAL �ACNffY MAP NOT TO SCALE i4%}ii f ... "_' E r. _ ,tom i STATIC PRFSStJRE _ ....... , ... , . 70 78 PSI 10Z SAF E7il FA cTzDR ... .. , .... 63.70. PSI RESIDUAL PRESSURE. . . ...., , . , . 50.79 PSI FLOW ...... . ................. L 500 0 GFA4 FROAr1. 3I15118 CATF : 3115116 .,.. SHEET NDE 9fT. # SIhE170WO 7 V F5--07 GEVERAL NOTES, PROJECT DATA AND DETAILS FS-0.2 aO7F PLAN — - FS--03 - FLOOR PLAN - FIRE SFMNKL.,ER HEAD LA YCXL76 FS-03 FLOOR PLAN - Fh9E SPRFNKL.ER FPWQ PLAN SCOPE OF WORK DESYGIV AND AISTALLAT70N OF ALL OVFR HF+AD PIPING AND SPMNKLER HEADS FOR F1Fi1t= SPHINKLER SYSTEM POINT OF CONNECTIONS FOF? RESIDENTIAL F}RE SYSTEMS IS LOCATED AT WATER SUPPLY PR'OWDE'D BY OTI-1E19S: SEE RISER DETAIL. ANC> FIRE SPRINKLER PLANS FOR LOCATIONS PROJECT DATA SUILDINO CODE' 13' CE3C, CEC3 CMC, CPC, CEC CFC. CA_ GBSC. TITLE 24, AA D ALL APPLICABLE LOCAL C00ES + GRL)iNANCES OCCUPANCYGROUP R-,'S SINGLE FAMILY RESIDENCE CONSTJRUCT70N TYPE V )VON -HATED AClTHOFRfTY HAVING .,A)RfSDIGi70N- RCFC INFRA STANDARD- NFPA OD. 2016 EDITION LECE ID FIRE 5`PR#Wl-S? RYURCX6 ( AM avw PpR+ pp= roEs j : SYSTEM _ 'sfN. v rr a ' RE5- EMUAL FLA T CONCEALED 14iG4d�CLFR R,cSER M4M"FO7LD r P t RESnCN7b4L i-LAT CONGEALED BEEWALL C DROP OR RGER 9ETWEEN FLOORS ( RESIDEAgML RECESSEO PE DENT ; w7nwEtyA rE ra,FERA ) "', HANGER ww1 RFSIDEIs VAL RECESSED PENDENT # wrrF�m ra yEpAnwL-! RING? HANGGER 10- OR RECESSED-9DEWALL 1ND1CA7ES PrEMA7E MAL CHANCE QR ACCESSED PENDENT rawmiLE� rrT ) 1__i HYDRAULIC NODE PIONMea-cALnmA7m s€-ftAw; Cf7 RECESS MEAVENT" r wii rn,Eta -raw ! r"t PIPE CAP (s:EPr.nds! ♦ SYMUOL WDICATES SP.RhVKL.ER ON CANOPY (4') FOM ALIFEGTOR TESTaq .4f1XLIARYDRAIN ra-AMrr.BLf SEE A-nAs1 OR L*YWOHi ® SMOKE PEL.A Y la=A cam.F r uAt� or ors = Ft-w J ( AP SPECDIRC APPLlCATWN UFRICFfT INTERIOR HORN re Apmrvfta iumt.uvsr oTmERs. a� PL e 7fC' SYfN Ot INL7IG4TES UPRIGHT ABQYE C4CiFCAd'Vk4 F13AA G HORN STROBEOFAFft)r AST•griED&Yo7l-Ef &—m M-Af&1 PIP TYPES , - rrp� ELECPWCAL BELL oFApm-rAHLE AsTA.Lw2rorPsst &FuFc-.uvs � ---� = INDICA TES C'VC P$PE COPPER PIPE' FU FY E DEPARTMENT CONA EC770N f r- Amwam � 9VOICA TES STEED. PIPE 5TI15a CMTR- 511T1 CFk NA&FACIMR I'Fmirl- 6A 4F1'F K-FACTOR - G fGE NP.7_ ANIN QE " DIMITY Q VIKING Y<494 VK4S4 200' 4-9 711161 1/2, WHITE RE5. FLAT CONCEALED 0-0 RELIAM-5 Fn^D41 R4483ta 1(>5' 4.7 Vic?, la' WHITE RE5- CONCEALED 81IDEWALL 0,05 { } CZLC E -r;FLA910 GL4B.10 115' 4-ci IA6' €f2' WHITE RE5. RECESSE0 rMIDENT D05 0 005 ' VCT.AL:LIG -140 FIFRS HSRU V2-140 R41435 115, 2100 4_1� �AvIII' 01/2'. 1/2, Ww— VG-�50 96;i.f�f]fE51ER f�EiD. f CF ED PENDENT CJ.R, REGE55E1D 51[DF-UAAL L REI-14BIE= CLOSE CrL OI CaL5601 2 5b1/2' UA41TE Q.R. REGE56EID F'1=h1DENT 02 ` RELIA5LE FIFR56 RA1414 28&' E,� 1/2' WHITE Q-R. RECE55ED PENDENT 0_05 VIKIPJG 4_ OP v9C3D0 2 E U`2' I 1 65 Q-P- IJPRi64 0.10 Alm T rCQ TY21W 200" 4.2 1116' I13' 6RA35 01Z UPRIGHT 0.10 • .�r . rr 3" CPVC r r FIRE SPRINKLER RISER Wf INTERIOR ACCESS ; t = - i II—F- --- �PANEL {14-1I2"x24") TYP. I I TO 112" BALL VALVE I DRAIN LINE PSI PRESSURE GAUGE TO DOMESTIC WATER SUPPLY I I FS FS1 $ ❑OMFSTIC SHUT OFF VALVE I i I (IF REQUIRED) I i + � 1" CPVC DRUBBER FACED CHECK VALVE TO IRRIGATION 1 1 (VVl IN -LICE CHECK VALUE) 1" COPPE# IL - PONT OF CONNECTION FOR 2 RESIDENTIAL FIRE SYSTEMS, IiNC- 11 II II MAIN SHUT OFF VALVE (IF REQUIRED) _ -��--m--i� 1-1I2" PVC S 1" WATER MkFi (FIELD VERIFICATION t" OOp�R K NlEEDED AT ROUGH INSTALLATION) T _ ar ti 1� PVC TO COPPER ADAPTER RISER DETAIL NOTES - - - LJNDERGRCUND WATER SUPPLY ON DETAIL SHOWN FOR REFERENCE ONLY AND INSTALLED BY 0714FRS - UNDERGROUND WATER SUPPLY LENGThG ARe OF WORST CASE SCENARIO RAID ARE REFLECTED ON RISER DETAIL AS WELL_ AS HYDRADLfc GAL.CULAT'IONS APPROVAL STAMP APPROVAL, f v�ra� Y Fi bepar r... �,�� Mar118I 6y, 1h a f cf lens and specfficayjons not ra Era , del�flon, �mfsArt or tully staifadan of arry requirernen� ofTl 2 4 or any ill OrdinanCM, Ca LJ'mm�an shall zip 24n aPWcvt!le and ,o5as tdr Mrs rr aur�soses until al by t+ie frr2 went R CEWE MAR 3 0 .2D13 CITY OE !.A QUINTA COMMUNITY DEVELOPMENT J Z2&5fCZ1rAND lIZT1,LLAT7ON8 i - RESIDENTIAL FIRE SYSTEMS INC, 8065 E CRYSTAL DERIVE ANAHEIM, CA 921307 TEL; 1-SCO-635-1656 FAX; 7I4-•666-2978 C-13* 786965 THE RECIPIENT OF THESE PLANS HERESY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS OR METHODS OF INSTALLATION COMAINED IN TEAR SET OF PLANS IS THE SOLE FROPEFITY OF RESIDENTIAL FIDE SYSTEMS Inc. AND THAT ANY USE OF THIS SET OF PJ._A#q519 PROHIBITED AND 15 A VIOLATION OF COPYRIGIRTS LAWS WM1 IC}UT FIRST )RECEIVING FERIVERON I=)ATOM rRESIIDENT1AL. 1`JI SYSTEMS Inc.. DEVELOPER MONARCH HOME 78080 CALLS AM100, SUITE 104 LA 0UINIA, CA, 92253 P OV.4E= T AA -- PROJECT DESIGNER! EIDGAR V R_F_S. tat REVIEW! GABRIEL V FLF.S. 2nd FEMEW- GABRIEL V I`FK ,JECT SUPERVISOR GABRIEL V 1 FOR RE IDEN71AL FIRE USE ONLY + DATIM IlACKGl0Ut 7° ARCH= 912iiM, 4.A17 NT DEM. - HOME APALAILE ' ME Id�STE ; I AVJLA&.E ELEo : 9217 MEN: 9-07 $Ti3UGT' M17 PLUVI3 RIN DELTA REVISIONS LATE T U4 L 1C,5Al,SE STAMP 00N CC�r•r 11E OMAL RPIE 0�1 srs ms PC + C-16 # 78M ExP- it o jib SHEET TITLE' GENERAL NOTES, SITE DA TA �- DETAILS JOB # DATE' 11458 1/24/18 SCALE: SHEET: N/A F —01 r + + + + + + + + + + + + + t + }+ + + I - + i t + + + + + + + + + - F + + + i + + I + # + + + + + + + + + + + + + + + + i + + + + f — +' i + + + + + + T + + + + T- 4- + + + + + f- + + 1 + + + + + + i F + i + + f k• + + + + + + - + + + + + + + + + + + 1 + + f- 4- + j F + + + + + + + + + _ - + + } + + + + + + i'; + + 4 + t 1 + _ k a + 4- + + + + + + + + I • �. � kl mil. F NORTH &+:ALE ZOW-Mr toSElam arName; aF :�rH'i.�'S PhW1eNO. ,�._;E n�. _=:t;,r ... Parcel No. 9.�� �,��:� ts io _ R SILe al Lat:r? 5. Ili. Tract i1b. Type of $ervk$. R-I: `r +Lk . P LJ Trlplax: JApis:SC: Arr�m � T - 5cc_ 7 +_ =_,T 'treatment: $2.435/edtt iQGki4Lr: S2,415/edu W-ter 31G Servick,. r.;=: v.: ::.;, Other:-Abar4oft both Water S--Mtcts. L40f" r:tn2flefltiy arW Lot4a w upsU� to a. I" mat or. 8�isfl�►� :;. . O #hrr; Note-t: Tratt No, ZW04-3, f#;���Vr��_ Lots 39940 have been Sew@r later,) nSetcd. P& Agri�erh er t. no W59FC And o -&y TFC ,�f SCit. IDwg. 33646 a 11SVCeX]5ts bSa DWg. 31103,a 4`• ;>�g e140., tS. pZ 148. Total:` - Z 1.,3 7 3 _Q x IF1 -- -'-- - _- - _ _ - - --- -_. - T chrttcian: RulseM M#611el :::...#u-d,; InrurmaVein'%pp lied &y Cu3t&'par -- 5q�t�a6 ngtcr mu. Flow= r; : ... �'� i Max. Flo►n''' Min -Pressure= ' �� �7.5I ^� inlet r'relsUrte'_�-___-_----10:72- psi FireStwrinkierDerna:'I � 4>atEetf�r2 l�r - ia<<, 4 75i IVlax. Flaw= ;I:?.: __. _ - Min, Pressure=.° Mulr� _ - 'SIa�►ri A�clr+a � I�i'i�r is F'ees��r� Re�i�ai1�F� �€�Eu�� --- .'------.. -' -- . � �n ��, � iat on �ur����-_fe►��� �9rtF3��t1a:�_inslltdes: C V W D U5E5 WORSTCASE CON DIRON iFru&RCmFT-"MIn'tiMrter Stop,Mewr_ r-nmkvas,,' L31I , a t,m- .1 METER Ixx� i icCa#suilt --` 151 1 "(1p. Ftf:V.- l:3 k, ,� Vix,f,�W 36.R3 GW41 v f_.QLK - - 4 r .$ Si]rin! 6ri fim a 1 _ _ r.l ..',ti_ _ -.Ap vad 4y; M - te' r + it 7be meter s#ting 15 Far pla n Cho EX purpatta.a". The asi ti� re►S:anriflbift residtmw4R:he #ke orv"sett- CMI.- PLAN DESIGNED BY: ES'SI EVC}lEE9#1G 7540 S91101=/5L0oLA LF STE Cr ,rTCA ffi CONTACT .. DE.943VAAD A UTALL A TA R1 Y P.ESIDEHITIAL..Km l k L �Wc. 80a5 E. CRYSTAL DH1VE ANAHEIM, CA 92607 TEL- 1-800-635-1656 FAX; 714-666-2978 C-16# 786965 THE FIMPIEN1 OF THESE PLANS HEFERY ACKNOWLEDGES THAT ALL PLANS, DETAILS, SPECIFICATIONS OR METHODS OF INSTALLATIQN CONTAINED IN THE SET OF FLANS IS THE SOLE PROPIEflTY OF FlFaDEMAL FIRE SYSTEMS Inc. AND THAT ANrf USE OF THE SEA" OF PLANS 13 FROHIBTED AND 15 A V70LATKM OF COPYRIGHTS LAWS WITHOUT FFIST f ECFANG FIRM ON FROM RESIDENTIAL FIRE SYSTEMS Inc. DI<VELCPE=R MONARCH HOMES 78080 CALLE A'-IGO. SUIT 104 LA OUIN 7 A, CA. M-53 f / f O iFC F / LA + PROJECT DESIGNER EDQAR V R_F -S_ 1st REVIEW: GABRIEL V R-F-S_ 2nd REVIEW- GAI3RJEL V PROJECT SUPEFYISOR: GASRIEL V +r FOR RESIQEIV'I IAL FIHE USE ONLY DATED aACKGFtOAW i AHC#I: RV.17 CML 4V P1F. DECO.: NX AVAL BL.E IRE WASa , I'ME AVAI.A91.E ELM - 917 11711, 9.0 STRl1CT: &M17 SIZ17 DF-LTA DATE REI+ISICPfS 0 - UCE/u5'E STAMP J JFE97mrw-1 iFE ff WMS INCry � C-16 # 78�965 18 j E�[P.11E)f�0e SHF=r=T TITLE. - SITE PLAN JOB # DATE! 11458 1/24/18 SCALE: f� SHEET- 111 " - 1'-01, F -02 I irS'.Aw • A. II�F. 4t � T rb- .-Ti - - '+,ii-•.'-.' 7P S17_.17 I.I d. F,�F1�5`T FLGGr� �LQ/J t READ zi x V REAR f"P L EGErl f7PE SPRrJtiJVCL ER SYM50f_5 r ss€ c ana SYSTEM COMFONEN7 S (sw f� . arm �cw a rras t RESIDEAMAL F _ A T CONCEALFo 0�0 FRE SPFJJNK L ER RISER A AAFOLD r PER =Agr ssFp„Aes, RESDEAInAL FLA T CG=EALED 505WALL Q DROP OR RISER DErWEEN FL RE AMDEN77AL RECESSED PENDENT fe►7s%F rra.TFTswEpAru�w_1 \ HAACER f67R§P) RESIDEN7Z4L RECESSED PENDENT wrEmiuuATH mmi'RATLsM j X RING HAA GER OR AECESSED S`IORWALL #VDfC4 TES PrjE fPE MA TEFX4L Ck4A O.R. F���D PEIUDL 7-(if TEi41PFlMMfr) [f"PO, (I HYDRAiLC NCDE PSI S f ipcALcu-A7ED, Sra-PLos) 0,9- QED PENDjFN7 c fiats-r AAA mw 1 r-1 PFE GAP (PuAsr + SYMSOL ADICA TES SPRAKLER ON CANOPY (4 ) i6�I "FECTOR TEST oy? AUXUARY DRAW s6EPLmrJ ) O O.R. 0-auHT F87R SUOKE RELAY f PA aat, . ar oThEn ssFF 4+ s AP _%-ECPG APPL MCA 77ON UPR ChT r fJVTEROF? HORN r F Arm_rA&L�- SYArfROL NDdCA TES UPRfGHT ABOVE CALF-OfiWIA Pf3AMWG FERN STROBE r ic,ar'rLcas�jE mrnr r Fn er orimst sE-= PJPE TYPES, f f rx�arrs maw nor rx a r � ELECTRICAL. SELL opAppLrAm.E aarALLm ar a7N-its sj rL �%AAG 1 - AOk—,A TES CPVC PPE — i i — — — i i — i — — — — — - !{V^-A TE,S C�,PPEFI P1YE FIRE DEPA RTMENT COWEC77ON r d-Amir�j= sEE Pu w r WDfCA TE,S STEEL. PJPE Mfl'O% COFFER STEEL CPYY- IIARFAMRR i' EL `aLIX T-11P K-FASTOR ORIFICE KF.T_ FINIE:ii•I 17E PTIOII ITr -- -- 1W VI INIG w4 '4 VK4144 200.1 4,3 11lrp" 112' UJ141TE RES. FLAT CONCEALED 0.0w -- -- -- RELIABLE w5 f 2 RA4a35 165' A.2 1f16' 112' WHITE RE9_ GONC=ALED 51DEWAL.tl 0-0- GLo5E 61_4 IO CSJ_ 41�lO I'S 4.s 'Tllib 1/2, LUNn RES- 1eECeESS AD f-LNUETIT 0&?), ' �� •- •. VfGTAIjI_jG 1a7+V Vi140 1-15' 4.9 TAir* 1/2' IJN1 VC-250 RE5. fREGEEPSED PENDENT 005 RELEIABLE HsLu RA1435 200— B4 14' 112' W-FLOr`r° IR aF_ Rr-CF55ED 51r)EWIALL 0.05 .: ... .. GLOSS GL401 GL.5601 200' 5.6 112' V2' LUWtE aF� REGE55ED PENDENT O. E. •• •• •• REL1ABLE FFFRW, 1; Af¢IA 28b, 5-6 112* Ir." WHITE CR. REGE55E=D PENDENT o- O -- -- -- VIKI V1C3po V<300 204' S-6 1/2, 112" BRA98 OR. UPR161 47 0-10 } -• -- •- Tyco AF I Tlr�Iw 2 4-2 1f16' 11/2' 1 BRA55 Q,R URRIeHT 0,10 103 TOTAL i • 17^- �a: I FIRS SPRENKLER PLAN (NFPA 13D) NOTES, - ALL COMPARTMENTS WITH 1 RESIDENTIAL HEAD TO BE SPACED @ �0'x20' MAX. ALL COMPARTMENTS VV17H 2 OR MORE RESIDEN'nAL HEADS TO BE SPACE] @ 1 E'x16' MA - - ONE IUPRIGHT TO 131< WST'ALLrm IN ATTIC AT 1~ A U - ALL FlPING TO DE 1" CPVC PIPL U.N.O. - ALL DROPS TO HEADS TO BE 3J4" CPVC PIPE - INDICATES CPVC PIPE _ 87' FLR AREA; 72W sqt# I TO TAL AREA, i 45 sgfL ' RAGEAFEA; 05Sot RE; EMUL SMKLER ATM TABLE 1 F10 — WPA 13D TMLE 625A2 : SPRINI(IJI t PognoN To AMD 0BSKICTIM TC DISCHAFIG MUMS F rM MAXUM ALLCh4AKE EWREF WRMQH TO WE OF D59LECTOR ABOUE BOTTOM OF 0SUR :T011 X OF OBSTRUCT +l IN] Im IEll LEW THAN T-0' CI" T-CI' To LESS THAN 1'-6' a" 1'--6' TO LEA THAN Z-W 1' i 2'-0' TO LESS THAN 2'-6- 1' 2'-6' TO LESS THAN 3'-0' 1' 3'-0' TO LIES THAN 3'-6' 3' 3'--6/yy' TOLESS THAN 4'-0" 3' �II 0' TO LESS THAN X-6' 51 4-6' TO LEW THAN 57-V 7y 5-V TO LESS THAN F- ' T Iy5iry,'--/61' .T�lrOa1 �LWEEaSS.aa}34. TTHH►(t�}N a6'-V �71 6+ 0' I O 4-+'+-ram+ THAN +A . 6'—G' .. 2�T &-B' TO LPSSTHAN 7r_W AI T-0' TO LESS THAN 7'-W ... 14' P X% = 9214.2 SLOPED CELM [IB 8 I !GUFF @25.4.3 - "KLEFI PMON TO AVOID 06311FL IC>t+l AOAII~1°7 WALLS 1� A A � &8'1 + E D q 30' 'HYM4 ULCAL L Y CAL C LA lED !7ml ass sra m o "wlu olr firs � FOR 1LET FLOOR. Mf !A_ F!f9.y 4+�171Y'I ice+. 11'hG ie DSGNO 70 D A T A FORTE OF Ars lid I MX PER SO F7 (MP.) OF FLGCH AFE4 OMF A Af74%aM AREA OF _ Ro . SOFA�+;� f (w WPW1R'A7S4AT}ELFR47E0F -- 3t9 [ 1d 11leP1'� AT J76 _P5I 00 A T ME AVE OF ThEf&M hMc.57WEAUALLOWANCE OF i6 AIGLD X TEE ARM OCGCJPANtY CU07CA TM FESEEN77AL 60W0M)7YCL4M9ICAjM4 SINGLEFAILY IVd47I kW STORAGE FSGHT WA WTALLED BY FESEEWRL FIE sYSTI:76dSids k 02 WUKE PRWM _ _ 6a! PSI 'HYDRA lLCALL Y CALCULATED SMFAo 7W SY8TE1Id AS Si,k?A Oil _ ENSKE ANYPOUFAU - DATED 112 FASTROOR AT c � f 2I1 MUMCi NO. us EVESUMEDTO0BCMRCFATAPATE OF am aw FER 50 FF W OF R_" AEA OVE7 A U4MOM AREA OF 4000 so FT: w I994w SYPPLAD WINE!WATMATPER4TEaw 25 WY{ ) AT XLl F5VN)ATTFEE45E0F?TEA5F hGE STRFAY7d1.LOwiAfXOP $_�G 0%0w E J GU00 A ThE AK E C6h9C0 iYCL4 Cli7XW SAJCtEF Y _ 1"WSTORAGEheft NIA ACTALLED BY PESDENTZ4L FF E SM7EW � WACE ftsgm _515 PSr RESIDENTIAL FIRE SYSTEMS INC. SOBS E- CRYSTAL DRIVE ANAHEIM, CA 92907 TEL.: 1--8O0y635-1656 FAX, 714-66E­2978 C-164 786965 THE FIECIPIENT OF THESE PLANS HEREBY ACKNOWLEDCZS THAT ALL PLATS, DETAILS, 9F'ECII=FCATIONS OR AAFTHOD5 OF I WTALLAT*N CMTAINED IN THIS SET OF PLANS 15 THE SOLE PnuO _-m ITY OF RESDENTIAL F IFF SYSTEMS hc. AND THAT ANY JSE OF THIS SET OF PLANS IS PROHIBITED AND 19 A VIOLATM OF COPYRU-ITS LAWS WITHOUT RRST RECEIVING PERMIESSON PROM RESIDENTIAL FIRE SYSTEMS Inc, DEVELQPER: MONARCH HOMES 78080 CALLE AMIGO, SUITE 104 LA OIJII TA. CA. 92253 PROJECT MAAA• PROJECT DESIGNER: EDGAR V R.FB, ist REVIEW: GAOnIEL V R.F.S. 2nd REVIEW: GABRIEL V PROJECT SUPERVISOR-- GABRIEL V * FOR RESIDENTIAL FIRE USE ONLY • DATED i9AeCICCit1011f DS ! Wigs ; 91W CK2. U 7 KI CECO : KA AVAALE HEAVE MOB: VE AVALAILE B.EC : 9AV : 9,1I7JT 814t>ICT: 8,O v Km: CS DELTA REVISIONS DATE FI fib LICENSE STAMP , 1��Tl4h# Op fi • FUIDENTIAL FIRE ' I SYSTEMS We. � i--ylUpA fJVVy�f'�1Jp7� ASH SHEET TITLE- FL OOR PLAN — FIRE SPRII VKLFR HFA0 L A YOUT' 006 # DATE: 11458 1/ 24/18 SCALE- SHEET. 1/4n=1—Dn F —03 0 NORTH t s". 4 Im: I DIM iq. I I ; I I I REAR YAiRD r �� 1rnSF#'r�.'y 'c'^ i C �JSY r YF F F//?c5T F—L -OOR Pl— AlJ J -R 2 CFO to EX16im REAR n':4• . I LEGEND FOE SPfPIWL.EFi S!'MGCXS r�P� a�.�a+�� r a': SYSTFY COMPONENTS rsEraAw .tmLe2 RESIDEAMAL FLAT CONCEALED FIRE SP4RVICLEA RISER MANF<XD c Pp DcrAz, sin -,mu) i HESIDE RAL FZA T CONCEALED S)E ALL 0 CROP OR RISER BETWEEN FL E RESVE A4L RECESSED PENDENT fvmmmmmwmA ww \ H.4NCEFR rsTw) ` f 5lDEl1�TI41l. R GESS D P&CeNT R#VG HANGER NO- O.R, RECESSED INDICATES PIPE MATERM L CHAIV OE ,SYDEWALL (f�j HYDRA LPTIF CALGYi C S Tom. Pia } O R P17CESSEO P00FAr' { A7F.%EDPA TF TE A n*L i f $ OR RECESSED PENDENT f fiC�f �7id'E) �1 PIPE Cf•IP f m-- A-,+ ) + SYMBOL kVDICA 71-S SPRINKLER ON CAACPY 6:0 WO INSPECTOR TES T m A(}.YILARY DRAAV ev= AvrL rca-acE. � ) SMOKE FELAY frAPPLr48LC A074LLM EYOMEW. SEE n-4W 3 OR UPRIGHT j AP SPECIP71C AFFLICA 77ON UPRIGHT INTERIOR HORN (r- omr-4pLa mTA4w sr cry; PL m ! C SYN4 OL NVDICA TES UPR)OHT ABO1 E CALJFORNIA FF(A1bdING hUM STAOBE r �P +cAAf F d Ai LEA srS P ) 1 I1fE TYPES ( F �7tP 19 ELECTRICAL BELL rjF-4m rAa aemwi gyor m=FR-kwi = INDICA TES CPVC PIPE -- —• — — — — — — — — — — — — — -- IJVDJUA TES COPPER PIPE � F1P4E DEP�4RT7ldENT CCNNECTADhF f I-arPuc ��alu�sJ _....—,.,.._,.�..�.._,._.,_,.�=NVCATES STEEL PIPE 5TM50L DWFER 5 EL GPVC I r**An, M Ya W. K-FACTOR OWCE R T- FM CEXHPTION De6M -_ •• �Ib VlKfPIC7 L C4 vK-4S4 200' d_S -1116' 1I2' lE1ATE FEES- FLdT coNc:E.AL1rD 0305 - -- -- W-LIABLE W54.2 RA4535 Kp,' 42 ille" 112' LkTt RES. CONCEALI D 5IDELUALL o.C5 -- - 5 GLOBE CsL4 Iv CxL4` ] C7 115' 4.9 SAW 1!2' WHITE RE5. RECE55ED PENDENT 0.0�p -- -- -- VICT-41JLIG V21 V?140 1 T5' 4.15 1116' 1/2' 4E44T. YC-250 RE5. FEC:E55E1) PENDF-NT 0.05 ► •• •• •• RELIABLE FIFIRd.6 N�II.1 R443�, 2CO' S,6 Ill' 112' Il1?t. S R OAR R1`Cr-35ED 60EIJ}AL_L 005 CaL�,dOl CzL5&0I 200' 5.6 II2, 1/2' LA41Tt= PENDENT 005 ' -• -• -- RELIABLE F1FFZ `6 RA°414 �30' 5b I12, II2' U)PiTE CF- KLGI=56�-D PENDENT oBb YAKINS V♦ 3PO VK300 200, 5-(2 IJ2' V2' BRA&5 IJP@ICSHT @,I{ �- -- -- TY'GO 4F' rr2I3a 2 4-2 -1/1W L 2° 13RA55 I 0-R- UPIR10147 I� TOTAL N.•0 R FIRE. SPRINKLER PLAN (NFPA 13D) NOTES- - ALL OMPARTMEIWTS WITH 1 RESIDENTIAL HEAD TO 6E SPACED & 2�'x20' MAX. ALL COMPARTMENTS WITH 2 OR MORE RESIDENTIAL HEADS TO BE SPACED @ 16'xl6' MAX. - ONE UPRIGHT TO BE INSTALLED IN ATTIC AT F.A.U. - ALL rIPING TO SE 1" CPVC PIPE U.N.O. - ALL DROPS TC HEADS TO BE 3I4" CPVC PIPE 1S'T FLR AREA: - 7282 OW1, I TOT4L AR£Ao 726.2 ell GARAr xE AREA- k'm sc# I FEUDS ffIAL SPRNKLER 08MLUTON TABLE / FO , JRE - NFPA 13D TeLE 82AU : SKULM F061ITCH TO AVOD OBS71I) T101+I6 TO 57IiARE X7MCE FROM MUMUM ALLOW WARCE SPRNKLER TO 9DE OF DEFLECTOR ADM EOrrOM OF ORMLIOnN IINJ OF Ce57LCnDN 10 {Ai 21 LESS THAN T-O' o' f-0' TO LESS THAN i'-5' T-6' TO LESS THAN Z-O' 2'-O' TO LESS THAN 2'--6' 1" 2'-fir' TO LESS THAN 3'-0' 1" I Z-O' TO LESS TITAN 3'-6' 3' I-G' TO LESS THAN 4'-0' 3' R-O' TO LESS THAN 4-4 5' 4-6' TO LESS THAN 5-9 7' 5-0' TO LESS THAN 5'--F 7' V- V TO LESS THAN V-0' T G-0' TO LESS THAN '-•6" 9' 6'-0' TO LESS THAN T-0' 11' T-W TO LESS 7HAN T-6' 14' ' SLMID CELNG 90JE k M42 '$A A CICii — La A 13 IE @.2. A 3 ; SPrINKLEN POSTION TO AVOU 005WTON A(KW WAILS s 0-81 + 8 p{3(r 'HYMAWCALLY CALW-ATED SY M eaTFdASSWI414ONi MCKSt!42� _ C0WA i4'ffNFNCJ - D47ED I124 FOR F F FLOM AT CA .4 NP 12 0 CONTPACTNO 1 2OE&1GWED TOAS"F4A AT R4 7E CF Cos GN VIN M So FL aW OF RDC R A TA OUP± A MAMdu AREA OF ma mFr (142) W-Ev&PPLED II'R WATER AT T}E RATEOF m GPM ) 47 S76 P,I (FRS) AT 7W SkSE OP 7W WER F05r-5Wi A4ALL0WAA 7E0F fUD0W7�E OCCPI XYCLASWrAWN AESDML C64Y09TYCLASSFrATM MOGLefAuu -- I4I,tX,ytfw b'T mGE hEag NIA ASTALLEDSY FEMENWWESrSI M. Fag FFSFFL (4 AT C4NAffiXM2 0FOWPACTAU JS DFSLa*D TO DeCVARM AT A RAM OF 05 jLW PER $0 Fr VA OF FLOT AFD OVS A U44lIAI# AREA OF 4mo SOFT V &- 0St1%W WIR WATER A T 7FE BITE OF 2$ (L WJ AT _- s3,o P51IaaW)ATM2A51E01F7r R80 MXE SThEAMALLOWANCE GIB 4 oww OXtFANC7'CLAg�#rA7JOAI _ RESEOVFAL COMUODffCLAS&FICAWN %Va EFAk&Y 8R);kC E H93NT NIA WrA+ r EO SY fE8EEN7d4L 0 E3r8TM W DES AAV AVTALL4 7& N BY RESIDENTIAL FIRE SYSTEMS INC. BOBS E. CRYSTAL DRIVE A NAHEIM, CA 92807 TEL- 1-800-CG5-1656 FAX: 714-666-2978 O-16# 756985 THE RECIPIENT OF TI-ESE PLANS HEREBY ACK"LEDGES THAT ALL PLANS: DETAILS, SPEC99CA71ONS OR METHODS OF INSTAUATON CONTAINED IN THIS SET CC - PLANS 19 7HE SOLE PROPERTY OF RESIDE"AL PRE SYSTEMS Inc. AND THAT ANY L SF OF TIS SET OF PLANS IS PROHIRTED AND IS A VIOLATION OF GOPYRGi78 LAWS WITHOUT FIRST RrzCBVING PEAMBSKM If OM FIEaDEhiTAL FIRE 5YE7E-M9 Inc„ DEVELOPER: MONARCH HONES MR CAL.I,.E AMIGO, SUITE 144 LA OUINTA, CA. 92253 PR0,1,E T Tj5A M PROJECT DESIGNIFR: EDGAR V FR.F.S, 1st REVIEW- GABRIEL V R.F.S. 2nd REVIEW= CA991EL V PROJECT SUPERVISOR: GABRIEL-. V v PDH RESIDENTIAL FIFE USE ONLY � - - ..-- ....... .. .. ..-......,... . DATID BA GKUDS ; ARCH; 912.17 Chl- 4,1117 W- D]EOI7.: HN AVALABLE FFE MAFF. NN AVAILABLE ELEC ; 9M MECK : R1211 81f11JCT: 9,E V PLJMD: RL917 DELTA REVISIONS DATE ►ilk m An Aa LfCENSE STAMP �#cr�ESI[}ENq �h+R��W�L�IF��E I CJYl•? EYE+. SHEET TITLE' FLOOR PLAN -- FIRE SkPRI1VICLER PIPE LA YOCIT' JOB # DATE: 11458 1/ 4/18 SCALE- SH E>=T- 114°=1'-O" FS-04 City of La Quinta In Cooperation With Riverside County Fire Department And CAL FIRE 78-495 Calle Tampico. La Quinta CA 92253 Direct: 760777-7000 j Main: 760777-7074 Fire and Life Safety Inspection Log/Order to Comply PAGE OF ' PERMIT/CASE # - ooSS FACILITY NAME FACILITY ADDRESS NOTICE NO.: DATE: CONTACT #: / The items below are in violation of or shall meet additional requirements of one or more of the following: 30' 9S7 ja'CAUFORNIA FIRE CODE □ CAUFORNIA BUILDING CODE _ □ LA QUINTA MUNIQPAL CODE .^NFPASTD. □ CCR TITLE □ OTHER - The listed violations/requirements shall be corrected immediately. A re-inspection will be conducted on or after fS20 FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL. 7 - iFOMC flbr •A SignatureReceived By x .T Fire Inspector IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074. Radio I.D. Residential Automatic Sprinklers Models GL4110 & GL4910 Pendent Recessed Pendent GLWBE FIRE SPRINKLER CORPORATION Description AND Operation The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profile yet durable design which utilize a 3mm fran gible glass ampule as the thermosensitive element. They feature economy, aesthetics and low flow. The combination of the 3mm frangible glass ampule and spe cially designed deflector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fire control. These Globe Pendent and Recessed Pendent Residential Sprin klers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direc tion of the approving authorities having jurisdiction. The heart of Globe's Model GL4110 and GL4910 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pres sure within the ampule exceeds the strength of the glass causing the glass to shatter. This results In water discharge which is distrib uted in an approved pattern. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. e4 ^ iLi I b \ /■ RESIDENTIAL PENDENT Technical Data • See reverse side for Approvals and Specifications. ■ Temperature Rating - 155°F (68“C), 175“F (79“C) • Water Working Pressure Rating -175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67^ (-55®C) • Frame - bronze • Deflector - brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size • Escutcheon Assembly - steel RESIDENTIAL RECESSED PENDENT * SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER TEMPERATURES N.F.P.A. MAXIMUM CEILING TEMPERATUREBULB COLORCLASSIFICATION msREDORDINARY INTERMEDIATE YELLOWr79;CI GFS-310 (Formerly A-1)DEC 2016 ft Residential Automatic Sprinklers Model GL4110 & GL4910 Pendent • Recessed Pendent Specifications and Approvals SIN NOMINAL K” FACTOR THREAD cULus NYC-DOB MEA101-92-E LENGTH FINISHESMODELSIZE EU Factory Bronze Chrome White Polyester^ Black Polyester’-* GL4110 4.1 (58 metric) 1/2”NPT (15mm) 21/2" (6.4cm)X X GL4910 4.9 (68 metric) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. ’FINISHES AVAILABLE ON SPECIAL ORDER. *AVAILABLEAS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. Installation Data for Flat and Sloped Ceilings** TEMPERATURE MAX. AREA OF COVERAGE* LENGTH X WIDTH Feel (Meters) MIN. DISTANCE BETWEEN SPRINKLERS Feet (Meters) *MIN. PRESSURE P.S.I. (bars) *MIN. FLOW G.P.M. (Umin.) SIN MODEL STYLE ISST (68®C) 175T (79»C) X X 12 (3.7) X12 (3.7)7.2 (.50)11 (42) PENDENT RECESSED PENDENT GL4110 X 14 (4.3) X 14 (4.3)8.6 (.59)12(45)8 (2.4) X X 16(4.9)x16(4.9)11.7 (.81)14 (53) X X 12 (3.7) X 12 (3.7)7.0 (.48)13(49) X X 14 (4.3) X 14 (4.3)8.2 (.57)14(53) PENDENT RECESSED PENDENT GL4910 X X 16 (4.9) X 16 (4.9)8.2 (.57)14 (53)8(2.4) X X 18 (5.5) X 18 (5.5)12.0 (.83)17(64) X X 20 (6.1) X 20 (6.1)16.7 (1.15)20 (76) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. •WHEN THESE SPRINKLERS ARE USED IN NFPA13 SYSTEMS. A0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. ‘•REFER TO PAGE 2 OF GLOBE’S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 13D AND 13R REQUIREMENTS. *FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED. USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIA ARE STATED. Cross Section Ordering Information SPECIFY • Quantity • Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 • Quantity - Recessed Wrenches - P/N 325391 • Quantity - Protective Caps - P/N 327109-CAP • (Friction Fit Recessed) 2 1S/16*DIA. I , 2'MIN. DIA. J HOLE IN CEILING U 1 29/32* DIA.—4 ~l 1* X 1/2* REDUCER •CUP I—1/8* MW. Ju S/8* MAX. Globe® Product Warranty 7 Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). CaLING 1/8RETAINER-!1* MIN. 1 1/2* MAX. 1/2” ADJUSTMENT RECESSED PENDENT 4077 AIRPARK DRIVE. STANDISH. MICHIGAN 48658 FAX 989-846-9231 www.globesprlnkIer.com 989-846-4583 1-800-248-0278 GLPBE FIRE SPRINKUR CORPORATION PRINTED U.S.A. DEC 2016 GFS-310 (Formerly A-1) Page 1 of 5 (S: MIKING FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N industriai Park Drive, Hastings Mi 49058 Telephone: 269-945-9501 Technicai Services: 877-384-5464 Fax: 269-818-1680 Emaii: techsvcs@vikingcorp.coni Visit the Viking website for the iatest edition of this technicai data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler Is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of celling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS e©us ‘-•sted (C-UL-US-EU): Category VKKW^ Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. EU 3. TECHNICAL DATA Specifications; Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 *F (-55 ®C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-fador shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 ®F (68 ®C) = B. 200 ®F (93 ®C) = E For example, sprinkler VK494 with a Brass finish and a 200 ®F (93 “C) temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter). Base Part No. 13642 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) UNS-C11000 and Brass UNS-C26800 Form No. F 012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) Page 2 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)MIKING TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.viklnggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: r,,c,D Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B. Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B. Painted White = M-/W, Painted ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 ‘’F/57 ®C = A For example, cover 13504 with a Polished Chrome finish and a 135 T/57 ®C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) "Requires a ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Cov’rr Phto >|Base Part ^ Number^ ... Cover Plato Bas»o Part Niiiribur 9 ;^sji;raret\ envoi Plato Baso Part Nunitiur ^Bulb Color .T^pefature^atliTg' ,V>ftheCoyer‘'^; AssembI, (RoqujrGd) ^!jy)axirnum^-r«^ Ambient I Coilinq reinpe r.ijuN Sprinkler j. Nominal '•Temperature^ M Sprinkler Temperature ClJ-tSific ition sm Red1539413642135 “F (57 “C)13504100 °F (38 *C) 150 T (65 "C) 155 °F (68 °C)Ordinary Green153941350413642135 T (57 *C)200 *F (93 "C)Intermediate Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome. Bright Brass. Antique Brass. Bmshed Brass, Brushed Copper. Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings^: ENT Footnotes ’ The sprinkler temperature rating Is stamped on the deflector. * Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. ® Maximum ambient temperature for cover assembly is 100 “F (38 *0). * Part number shown is the base part number. For complete part number, refer to current Viking price , list schedule. * The corrosion resistant coaflngs have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfeces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F 012116 17.04.20 Rev 17.2 V Page 3 of 5 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)MIKING TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com L Gsms'i <is niriKlGr' '»H - ■*' •V' -A’ mHo^CeiliiiJ IVFJi r“if r tos rdit^^fNF^R Nominai K-FactorNPT Thread Size Maximum Water Wor king Pressure Sprinkler Base Part Number^SIN metric ^U.S.Inches mm 175 psi (12 bar)70.6■ 1/2 15 4.9VK49420759 FlowMax. Coverage Area^ WXL Ft. X Ft. (m X m) Listings and Approvals’® Pressure PSI (bar) Minimum SpacingGPMDeflector to Ceiling Installation Type(LPM)Ft.c©us'155T{68*C), 200T(93“C)Temperature Rated Sprinklers (m) EU 13 7.012X12 (3.7 X 3.7)(0.48)(49.2) •13 7.014X14 (4.3 X 4.3)(0.48)(49.2)Concealed with Cover Plate Assembly. See Footnote 9. 87.013 See Footnotes 7,10, & 1116X16 (4.9 X 4.9)Refer to Figure 2 (2.4)(0.48)(49.2) 12.01718X18 (5.5 X 5.5)(0.83)(64.4) 16.720X20 (6.1 X6.1) 20 (1.15)(75.7) Footnotes ’ Part number shown is the base part number. For complete part number, refer to current Viking price schedule. * Metric K-fector measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. ^ This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. * Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. * Meets New York City requirements, effective July 1. 2008. * For areas of coverage smaller than shown, use the 'Flow’ and 'Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to wails shall not exceed one-half the sprinkler spacing indicated for the minimum 'Flow" and “Pressure’ used. ' Cover Temperature Rating is'135 'F (57 'C). Cover Part No. 13504’, 13642' (large diameter), or 15394’ (square cover plate). ® Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black ®. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 10 Form No. F 012116 17.04.20 Rev 17.2 Page 4 of 5 MIKINQ FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Visit the Viking website for the latest edition of this technical data Email: techsvcs@vikingcorp.com page www.vikinggroupinc.com DESIGN CRITERIA T to the Approval Chari on p ULListing Requirements fC-UL-US.EU\: “ “ — -ni™. • The flow rates gwen in the Approval Chart for NFPA13D and NFPA13R applications for each listed area of coverage, or n Calculated based on a minimum disdiarge of 0.1 gpm/sq. ft. over the “design area" in accordance with sections 8 5 21 • Minimum distance between residential sprinklers; 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. XPreferto' for ranTril! 'O'- Residential Sprinkler Handling and Installation. aonSle P-'^visions of governmeSta codes, ordfnances and standSJ^d?^^^^Having Jurirdiction ^ acceptance of all residential sprinkler installations must be obtained from the Authorities or 8.6.2.1.2 of NFPA 13. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** 2-1/4” (57 mm) diameter opening required in the ceiling. Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler frame arms Figure 1: Sprinkler Installation and Proper Wrench Usage ** A1/2" ratchet is required (Not available from Viking) FormNo. F 012116 17.04.20 Rev 17.2 Page 5 of 5 (E MIKING FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.g) TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone; 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com l I MIKING' All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. •4- 3-5/16” (84 mm) Figure 3: Identification of Custom Paint for Concealed Covers Figure 4: Square Cover Assembly 15394 FormNo.F 012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) i WFDTN Series Waterflow Detector System Sensor WFDTN T-Tap Waterflow detectors are designed for primary signaling in residential systems and branch line signaling. The new WFDTN Series waterflow detectors from System Sensor consists of a rugged, NEMA 4-rated enclosure that is more damage resistant than previous metal designs. The waterflow detector is designed for both indoor and outdoor use, with the widest available temperature range, from 32®F to ISOT. Features New directional cover allows installers and inspectors to easily see the direction of flow UL-listed models are NEMA 4 rated New cover provides a better seal, is lighter weight, not painted and corrosion resistant Sealed retard mechanism immune to dust and other contaminants Less exposed metal reduces shock hazard, plastic cover acts as insulator and is resistant to arcing Visual switch activation Audible switch activation (73 dBA) Field-replaceable timer/switch assembly Accommodates up to 12 AWG wire Switch Synchronization activates both alarm panel and local bell or horn strobe Tamper-resistant cover screws Improved water sealing Reduced product weight Wire-ready terminals Improved wiring with new terniinal block layout Snap-in optional cover tamper switch Both the WFDTN with incorporated timer and WFDTNRN with immediate activation fit any tee that has a 1 in. NPT branch, including: lin,, 11/410., IVt in. and 2in. NPT threaded ferrous and brass tees; lin., I^Ain., IV^in.and 2in. copper sweat tees; Tyco. Spears, NIBBCO brand 1 in. CPVC tees. Twelve different clearly marked plastic paddles are available to fit different Installation configurations. UL-listed models are equipped with tamper-resistant cover screws to prevent unauthorized entry. Inside, two sets of SPOT (Form C) synchronized switches are enclosed in a durable terminal block with new layout designed to make wiring easy with wire ready terminals, COM terminals are on a different elevation, large barrier between switches and easy to read raised textured lettering all make wiring easy. An optional cover tamper switch is available, securely snaps into place, no tools required. The WFDTN incorporates a mechanical time delay feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the fire sprinkler system. The larger and easy to turn timer dial makes setting the waterflow detector easy with high contrast pad printed markings. The dial offers three tabs to help with turning, with one larger tab located on the dial position for approximately 60 seconds, a notch is also indicated on the dial to locate approximately 30 seconds making setting the detector in dimmly lit locations easy. Agency Listings The WFDTN series is designed for accuracy and repeatability. The detector also offers improved performance during vibration in riser ^plications where detectors are exposed to a large in rush of water. C US LISTED APPROVED S739 7770-1653:0231 30S122E6 • ^ .J 9- Waterflow Detector Specifications fflEngineering Spebificatibns Model shall be WFDTN or WFDTNRN as manufactured by System Sensor. T-Tap waterflow detectors shall be installed on a tee that has a 1 in. NPT branch inciuding: lin., llAin., iy2in. and 2in. NPT threaded ferrous and brass tee; 1in., VA\r\., 1 Viin. and 2in. copper sweat tees; Tyco. Spears. NIBBCO brand lin. CPVC tees as designed on the drawing and /or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run at least e'from any fittings or valves that may change water direction, fiow rate, or pipe diameter or no closer than 24in. from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 375 psi. The WFDTN detector with incorporated time deiay mechanism shall respond to waterflow in the specified direction after a preset time delay that is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual and audible indication of actuation, The actuation mechanism shall include a ethylene vinyl acetate vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPOT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. Standard^Specifications Static Pressure Rating 375 PSI Operating Temperature Range 32°F to 150°F (O^C to 60®C) Maximum Surge 18 Feet Per Second(FPS)Enclosure Rating*NEMA 4 - suitable for indoor/outdoor use Triggering Threshold Bandwidth (Flow Rate) 4-10 GPM CoverTamper Switch Standard with ULC models, optional for UL models, part no, CTS Conduit Entrances Two openings for Vain, conduit. NEMA 4 rated plugs Service Use Automatic Sprinkler; NFPA-13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R Nationai Fire Alarm Code; NFPA-72 Contact Ratings Two sets of SPOT (Form C) 10.0 A, /a HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC U.S. Patent Numbers 5,213,205 Compatible Tee Rttings Threaded ferrous and brass tees, copper sweat tees, CPVC tees. Warranty 3 Years WFDTN Field Wiring Diagram Overall Dimensions, Installed 3-1/2' SSM24-X SSV120'X UL-USTED COMfATIBLE CONTROL PANEL NOTE: COMMON AND B-NO CONNECTIONS WILL CLOSE WHEN VANE IS OEFLECTER I.E.. WHEN WATER IS PLOWING.OUAl SWITCHES PERMIT APPUCATIONS TO BE COMBINED ON A SINGLE DETECTOR. W POWER 24VDCOR 120VAC 2-S/8' CONTACT RATINGS SUGGESTED EOL RESISTOR£ 125QS0VAC 10AMPS 4'INITIATING LOOP 24 VDC 2.SAMPS ■S’A/V TEEA-NCSCHEMATIC OF INDIVIDUAL SWITCH IN ■NO WATERFLOW CONDITION ADAPTER COM A.INSTALLATION GAUGE ENDGFPADOLETREE MUST fUBEIWEENTOPOFTEE AND BOnOMOF FLANGE B-NO\ TEE DEPTHBREAK WIRE AS SHOWN FOR SUPERVISION OF CONNECTION. DO NOTALLOW STRIPPED WIRE LEADS TO EXTEND BEYOND SWITCH HOUSING. DO NOT LOOP WIRES. -TEE FITTING •PLASTIC VANE DESIGNEDTOflTWrrHIN2X4STUDWAaCONSTRUaiON Ordering'Information DescriptionUU Model ULC Model WFDTNA Waterflow Detector, Fits lin., IViin., 1V4in,.2in. ferrous and brass threaded tees; 1in., VA\n., 1 Viin,, 2in. copper sweat tees; lin, CPVC tees. WFDTN WFDTNRN Waterflow Detector without incorporated time delay mechanism, fits same tees as WFDTN Accessories FS-RT Delay mechanism and switch assembly CTS Tamper-proof switch kit WFDW Tamper-proof wrench for cover 3825 Ohio Avenue • St. Charles, IL 60174 Phone; 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com @2016 System Sensor. Ffoduei speciFicaticns suBjeci to cPange wiihoui notice. Visit sysiemsensof.com lor cunem product information, hchjding me latest version tt mis data sheet WFDSSS003* 11/16Vj# Sensor' INC.RESIDENTIAL FIRE SYSTEMS, 8085 EAST CRYSTAL DRIVE ANAHEIM, CA. 92807 HYDRAULIC CALCULATIONS FOR HICKS RESIDENCE 1 HD CASITA BEDROOM 2 CALC FILE NUMBER: 11458 JAN 26, 2018DATE: -DESIGN DATA- NFPA 13D, 2016 EDITIONOCCUPANCY CLASSIFICATION: 0.05 gpm/sq. ft.DENSITY; 400.0 sq. ft.AREA OF APPLICATION: 400.0 sq. ft. max.COVERAGE PER SPRINKLER: 1 sprinklersNUMBER OF SPRINKLERS CALCULATED; 20.0 gpmTOTAL SPRINKLER WATER FLOW REQUIRED: 25.0 gpmTOTAL WATER REQUIRED (including hose): gpm @ 33.0 psi20.0FLOW AND PRESSURE (@ BOR): 7/16 inchSPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: RESIDENTIAL FIRE SYSTEMS, INC DESIGN/LAYOUT BY: EDGAR V AUTHORITY HAVING JURISDICTION: RCFD CONTRACTOR CERTIFICATION NUMBER: 786965 CALCULATIONS BY HASS COMPUTER PROGRAM , HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS DATE: l/26/2018inklers\Calcs\Initial\lHD - CASITA BEDROOM 2 CALCS FSP.sdf n JOB TITLE: Page 2 WATER SUPPLY DATA SOURCE NODE STATIC PRESS. (PSD RESID. PRESS. (PSD FLOW AVAIL. PRESS. (PSD TOTAL @ DEMAND (GPM) REQ'D PRESS. (PSD @ TAG (GPM) 64.0SRC 20.0 1500.0 64.0 25.0 52.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 25.0 GPM 0.0 GPM 5.0 GPM 20.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE (PSD DISCHARGE (GPM)(FT) 1 10.0 10.0 10.0 10.5 10.0 10.0 13.0 14.0 13.0 12.0 12.0 10.0 10.0 10.0 12.0 13.0 10.0 18.9 18.9 18.9 18.7 18.3 16.7 18.7 19.7 21.8 23.3 24.8 27.1 26.7 25.4 23.1 19.9 28.3 33.0 34.3 36.5 38.4 42.4 52.5 2 3 4 5 6 K= 4.90 20.0 7 8 9 10 11 12 13 14 15 16 TOR BOR 3.0 U1 2.0 HOSE STREAM 5.0 U2 -2.0 -2.0 -2.0 -4.0 U3 U4 SRC SOURCE 25.0 ^ 7 'Page 3 DATE: l/26/2018inklers\Calcs\Initial\lHD - CASITA BEDROOM 2 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS PIPE DATA Q(GPM) DIA(IN) PT DISC. VEL(FPS) HW(C) FL/FT LENGTH (FT) PRESS. SUM. (PSD PIPE TAG END ELEV. NOZ. NODES (FT)(PSI) (GPM)(K) PF 0.0 PE 0.0 0.0 1.101 PL 150 FTG 0.000 TL 9.41Pipe; 1 10.0 10.0 0.0 18.9 18.9 0.0 0.0 2E1 0.0 0.0 23.41 PV2 0.0 1.101 PL 150 FTG 0.000 TL 0.50 PF 0.0 PE 0.0 Pipe: 2 0.0 0.0210.0 10.0 0.0 18.9 18.9 ET 12.50 PV0.0 0.03 0.0 1.101 PL 150 FTG 0.000 TL 38.33 PF 4F3E3R PE -0.2 66.33 PV 0.0Pipe: 3 0.010.0 10.5 0.0 18.9 18.7 0.02 0.0 0.04 1.101 PL 150 FTG 0.020 TL 12.09 2ETR 32.09 PF 0.6 PE 0.2 10.2Pipe: 4 10.5 10.0 0.0 18.7 18.3 0.0 3.44 0.0 0.0 PV5 20.0 1.101 PL 150 FTG 0.068 TL 9.91 PF 1.6 PE 0.0 Pipe: 5 2E18.3 16.7 0.0 6.710.0 10.0 0.05 23.91 PV4.9 20.06 48.00 PF 1.7 3F4ET8R PE -1.3 92.00 PV -9.8 1.101 PL 150 FTG 0.018 TL Pipe: 6 0.0 3.310.0 13.0 0.0 18.3 18.7 5 0.00.07 1.101 PL 150 FTG 0.018 TL 52.09 PF 2E2T7R PE -0.4 83.09 PV 1.5-9.8Pipe: 7 18.7 19.7 0.0 3.313.0 14.0 0.07 0.00.08 57.66 PF 1.6 4F2ET7R PE 0.4 87.66 PV -9.8 1.101 PL 150 FTG 0.018 TL Pipe: 8 0.0 3.314.0 13.0 0.0 19.7 21.8 8 0.00.09 -9.8 1.101 PL 150 FTG 0.018 TL 39.33 PF 4F2E4R PE 61.33 PV 1.1Pipe: 9 0.43.30.0 21.8 23.3 0.0913.0 12.0 0.0 0.010 1.101 PL 150 FTG 0.018 TL 38.50 PF 1.4 4F5E2R PE 0.0 79.50 PV -9.8Pipe: 10 0.0 3.312.0 0.0 23.3 24.8 10 0.012.0 0.011 1.101 PL 150 FTG 0.018 TL 48.75 PF 6F2ET6R PE 79.75 PV 1.5-9.8Pipe: 11 0.924.8 27.1 0.0 3.'312.0 0.011 0.010.0 0.012 11.75 PF 0.3 TR PE 0.0 17.75 PV 10.2 1.101 PL 150 FTG 0.020 TL Pipe: 12 0.0 3.40.0 27.1 26.7 12 10.0 0.00.01310.0 .»■ • •Page 4 DATE; l/26/2018inklers\Calcs\Initial\lHD - CASITA BEDROOM 2 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS PIPE TAG END ELEV. NODES (FT) Q(GPM) DIA(IN) LENGTH PT DISC. VEL(FPS) HW(C) FL/FT (FT) PRESS. SUM. (PSD NOZ. (K)(PSD (GPM) Pipe: 13 -20.0 0.0 6.7 1.101 PL 150 FTG 0.068 TL 4.25 ET2R 18.25 1.2PF 12 10.0 0.0 27.1 28.3 0.0 •PE 10.0TOR 0.0 0.0 PV Pipe: 14 10.2 0.0 3.4 1.101 PL 150 FTG 0.020 TL 49.66 6FT9R 69.66 1.4PF 13 10.0 10.0 0.0 26.7 25.4 0.0PE 14 0.0 0.0 PV Pipe: 15 10.2 0.0 3.4 1.101 PL 39.50 PF 150 FTG 4F4E2R PE 0.020 TL 73.50 PV 1.4 14 10.0 12.0 0.0 25.4 23.1 -0.9 15 0.0 0.0 Pipe: 16 10.2 0.0 3.4 1.101 PL 150 FTG 8F7E9R PE 0.020 TL 138.91 PV 72.91 PF 2.7 15 12.0 13.0 0.0 23.1 19.9 -0.4 16 0.0 0.0 Pipe: 16A 13.0 10.5 10.2 0.0 3.4 1.101 PL 56.66 PF 150 FTG 6F7E6R PE 0.020 TL 117.66 PV 2.3 16 0.0 19.9 18.7 1.1 4 0.0 0.0 Pipe: 100 10.0 -20.0 0.0 6.7 1.101 PL 150 FTG 0.068 TL 8.00 E2RC 25.00 1.7PF 0.0TOR 28.3 33.0 3.0PE 3.0 0.0BOR 0.0 PV Pipe: 103 -20.0 0.0 7.8 1.025 PL 150 FTG 0.096 TL 3.00 0.9PF 3.0 0.0 33.0 34.3 BOR 2E 0.4PE U1 2.0 5.0H.S.9.00 PV Pipe: 104 -25.0 5.0 4.5 1.505 PL 150 FTG 0.022 TL 6.50 PF ETG PE 20.50 PV 0.5 U1 2.0 34.3 36.5 H.S.1.7 U2 -2.0 0.0 0.0 Pipe: 105 -2.0 -2.0 -25.0 0.0 4.0 1.598 PL 150 FTG 0.017 TL 112.00 85.00 3E 1.9PF U2 0.0 36.5 38.4 PE 0.0 U3 0.0 0.0 PV Pipe: 106 -2.0 -2.0 FIXED PRESSURE LOSS DEVICE 4.0 psi.25.0 gprtiU40.0 42.4 38.4 0.0 U3 0.0 0.0 Pipe: 107 -2.0 0.0 42.4 -4.0 SRCE 52.5 (N/A) -25.0 0.0 10.3 0.995 PL 35.00 PF 9.3 150 FTG 0.168 TL 55.00 PV TX PE 0.9U4 SRC Page 5 DATE: l/26/2018inklers\Calcs\Initial\lHD - CASITA BEDROOM 2 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS NOTES (HASS): (1) Calculations were performed by the HASS 8.7 computer program in accordance with NFPA13 (2017) under license no. 38061304 granted by HRS Systems/ Inc. 208 Southside Square Petersburg/ TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.010 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 10.3 ft/sec at pipe 107. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SRC under full flow conditions is 63.97 psi with a flow of 27.80 gpm. (6)- PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP HWC: 150 Equivalent Fitting Lengths in Feet PAGE: F Diameter (in) MATERIAL: CPVC K C GETRF El Tee RunT Kplg ChkVlv 1.00 7.00 5.00 1.00 1.00 8.00 2.00 9.00 8.00 1.00 1.00 14.00 45 Gate 2.00 3.00 1.101 1.598 HWC: 150 Equivalent Fitting Lengths in Feet MATERIAL: CT-KPAGE: K Diameter (in)K C G N XTFRE Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee AngVlv 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00. 14.000.995 HWC: 150 Equivalent Fitting Lengths in Feet MATERIAL: CT-LPAGE: L Diameter (in)C G NFRKET Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 3.00 7.00 1.00 2.00 0.00 7.00 0.00 7.00 4.00 9.00 2.00 3.00 0.50 10.00 0.00 9.00 1.025 1.505 a o > CO 1-3WATER SUPPLY ANALYSIS Static: 64.00 psi Resid: 20.00 psi Flow: 1500.0 gpm Ri t-3 •• 80.0 1-3 M f LEGEND Available pressure 63.98 psi @ 25.0 gpm NJ •• <Xi to o 70.0 CO Required pressure 52.54 psi @ 25.0 gpm H- 3 1 (D 1-1 W « fpG 60.0 O H fu Z!-■ 5^ O tr* w tn u G 2 E A. Source Supply Curve D M H- K rr w P* H (D M S 50.0 B. System Demand Curve P R M EG X h; O D E 40.0S IS a o t-* > MCO o I1-3 > > Z w W K O CO 50 M O CO > u R 30.0 E P 20.0 o s toi o > f o10.0 %CO % CO fp fp (U m iQ a CD0.0 l-h <Tl V -14.7 1^00 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source ^5o ft1011 0 ^00 I Page 7 DATE: l/26/2018inklers\Calcs\Initial\lHD - CASITA BEDROOM 2 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM H.YDRAULIC ANALYSIS WATER SUPPLY CURVE 72+ 66+ 0\ \ \ 60+ \\ \ \ \ W54+ \X \ \ WP 48+ \R \E \S WS 42+ \U \R wE \36+ \( \P Ws \I 30+ \ \ W \24+ \ \ * <-20.0 psi @ 1500 gpm Flow Test Point18 + 12+LEGEND X ® Required Water Supply 52.54 psi @ 25.0 gpm 6+ 0 =* Available Water Supply 63.98 psi @ 25.0 gpm ++■+■+0++-+ + 400 600 800 1000 1200 ++■■+ 2000160018001400 FLOW (GPM) ¨ RESIDENTIAL FIRE SYSTEMS, INC. 8085 EAST CRYSTAL DRIVE ANAHEIM, CA. 92807 HYDRAULIC CALCULATIONS FOR HICKS RESIDENCE 2 HD CASITA BEDROOM 1 CALC FILE NUMBER: 11458 DATE: JAN 26, 2018 “DESIGN DATA- NFPA 13D, 2016 EDITIONOCCUPANCY CLASSIFICATION: 0.05 gpm/sq. ft.DENSITY: 512.0 sq. ft.AREA OF APPLICATION: 256.0 sq. ft. max.COVERAGE PER SPRINKLER: 2 sprinklersNUMBER OF SPRINKLERS CALCULATED: 26.3TOTAL SPRINKLER WATER FLOW REQUIRED:gpm TOTAL WATER REQUIRED (including hose):31.3 gpm 2 6.3 gpm @ 37.6 psiFLOW AND PRESSURE (0 BOR): 7/16 inchSPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: RESIDENTIAL FIRE SYSTEMS, INC DESIGN/LAYOUT BY: EDGAR V AUTHORITY HAVING JURISDICTION: RCFD CONTRACTOR CERTIFICATION NUMBER: 786965 CALCULATIONS BY HASS COMPUTER PROGRAM , HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: l/26/2018inklers\Calcs\Initial\2HD - CASITA BEDROOM 1 CALCS FSP.sdf • JOB TITLE: WATER SUPPLY DATA SOURCE NODE STATIC PRESS. (PSD RESID. PRESS. (PSD FLOW AVAIL. PRESS. (PSD REQ'D PRESS. (PSD TOTAL @ DEMAND (GPM)TAG (GPM) SRC 64.0 20.0 1500.0 64.0 31.3 63.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 31.3 GPM 0.0 GPM 5.0 GPM 26.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE (PSD DISCHARGE (GPM)(FT) 1 10.0 10.0 10.0 10.5 10.0 10.0 13.0 14.0 13.0 12.0 12,0 10.0 10.0 10.0 12.0 13.0 10.0 K= 4.90 7.0 13.0 2 7.8 3 K= 4.90 7.4 13.3 4 15.0 16.1 16.1 17.4 19.3 22.2 24.4 26.6 29.7 29.1 26.7 23.3 18.0 31.8 37.6 39.5 41.9 44.8 48.8 63.7 5 6 7 8 9 10 11 12 13 14 15 16 TOR 3.0BOR U1 2.0 HOSE STREAM 5.0 U2 -2.0 -2.0 -2.0 -4.0 U3 U4 SRC SOURCE 31.3 t Page 3 DATE: l/26/2018inklers\Calcs\Initial\2HD - CASITA BEDROOM 1 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS PIPE DATA Q(GPM) DIA(IN) LENGTH PT DISC. VEL(FPS) HW(C) FL/FT (FT) PRESS. SUM. (PSD PIPE TAG END ELEV. NOZ. NODES (FT) (K)(PSI) (GPM) -13.0 13.0 4.4 1.101 PL ISO FTG 0.031 TL 9.41 PF 0.7 PE 0.0 Pipe: 1 7.0 2E10.0 10.0 4.91 23.4120.0 7.8 0.0 PV 13.3 0.0 4.5 13.3 1.101 PL 150 FTG 0.032 TL 0.50 PF 0.4 PE 0.0 Pipe: 2 2 10.0 10.0 0.0 7.8 ET 12.504.9 7.43 PV -26.3 0.0 8.9 1.101 PL 150 FTG 0.113 TL 38.33 PF 4F3E3R PE -0.2 66.33 PV 7.5Pipe: 3 7.8210.0 10.5 0.0 15.0 0.040.0 Pipe: 4 -12.4 0.0 4.2 1.101 PL 150 FTG 0.028 TL 12.09 PF 0.9 2ETR PE 0.2 32.09 PV 10.5 10.0 0.0 15.0 16.1 4 5 0.0 0.0 Pipe: 5 0.0 1.101 PL 150 FTG 0.000 TL 9.91 PF 0.0 2E PE 0.0 23.91 PV 16.1 16.1 0.0 0.0510.0 10.0 0.0 6 0.0 0.0 1.101 PL 150 FTG 0.028 TL 48.00 PF 2.6 3F4ET8R PE -1.3 92.00 PV Pipe: 6 -12.4 5 10.0 13.0 0.0 16.1 17.4 0.0 4.2 0.0 0.07 1.101 PL 150 FTG 0.028 TL 52.09 PF 2E2T7R PE -0.4 83.09 PV 2.3Pipe: 7 -12.4 0.0 4.213.0 14.0 0.0 17.4 19.3 7 0.080.0 1.101 PL 150 FTG 0.028 TL 57.66 PF 2.5 4F2ET7R PE 0.4 87.66 PV Pipe: 8 -12.4 0.0 4.2814.0 13.0 0.0 19.3 22.290.0 0.0 Pipe: 9 -12.4 0.0 4.2 1.101 PL 150 FTG 0.028 TL 39.33 PF 1.7 4F2E4R PE 0.4 61.33 PV 9 13.0 12.0 0.0 22.2 24.40.0 0.010 Pipe: 10 -12.4 0.0 4.2 1.101 PL 150 FTG 0.028 TL 38.50 PF 4F5E2R PE 79.50 PV 2.2 0.01012.0 0.0 24.4 26.612.0 0.0 0.011 -12.4 0.0 4.2 1.101 PL 150 FTG 0.028 TL 48.75 PF 2.2 6F2ET6R 'PE 0.9 79.75 PV Pipe: 11 0.0 26.6 29.7 11 12.0 10.0 0.0 0.012 1.101 PL 150 FTG 0.035 TL 11.75 PF 0.6 TR PE 0.0 17.75 PV Pipe: 12 13.9 0.0 4.70.0 29.7 29.1 12 10.0 10.0 0.0130.0 Page 4 DATE: l/26/2018inklers\Calcs\Initial\2HD - CASITA BEDROOM 1 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS 9 ^ I Q(GPM) DIA(IN) DISC. VEL(FPS) HW(C) FL/FT PRESS. SUM. (PSD LENGTH (FT) PIPE TAG END ELEV. NOZ. PT NODES (FT) (K) (PSI) (GPM) 2.11.101 PL 150 FTG 0.113 TL 4.25 ET2R 18.25 PF-26.3 0.0 8.9 Pipe: 13 0.0PE0.0 29.7 31.8 10.012 0.0 PV0.010.0TOR 49.66 150 FTG 6FT9R 69.66 2.41.101 PL PF13.9 0.0 4.7 Pipe: 14 0.0PE29.1 26.7 10.0 0.013 0.035 TL PV0.010.0 0.014 2.539.50 PF 150 FTG 4F4E2R PE 73.50 PV 13.9 0.0 4.7 1.101 PLPipe: 15 -0.926.7 23.3 10.0 0.014 0.035 TL0.00.012.015 4.81.101 PL 72.91 PF 150 FTG 8F7E9R PE 0.035 TL 138.91 PV 13.9 0.0 4.7 Pipe: 16 -0.423.3 18.0 12.0 0.015 0.00.013.016 1.101 PL 56.66 PF 150 FTG 6F7E6R PE 0.035 TL 117.66 PV 4.113.9 0.0 4.7 Pipe: 16A 13.0 10.5 1.10.0 18.0 15.0 16 0.00.04 2.81.101 PL 150 FTG 0.113 TL 8.00 E2RC 25.00 -26.3 0.0 8.9 PFPipe: 100 10.0 3.0PE31.8 37.6 0.0TOR PV0.03.0 0.0BOR 3.00 1.4'-26.3 0.0 10.2 1.025 PL 150 FTG 0.160 TL PFPipe: 103 0.42EPE0.0 37.6 39.5 3.0BOR 9.005.0 PV2.0U1 H.S. 0.71.505 PL 6.50 150 FTG ETG 0.034 TL 20.50 -31.3 5.0 5.6 PFPipe: 104 1.7PE39.5 41.9 2.0 H.S.U1 0.0 PV0.0-2.0U2 2.81.598 PL 150 FTG 0.025 TL 112.00 85.00 3E -31.3 0.0 5.0 PFPipe: 105 -2.0 -2.0 0.0 PE41.9 44.8 0.0U2 PV0.00.0U3 FIXED PRESSURE LOSS DEVICE 31.3 gpm4.0 psi/ Pipe: 106 -2.0 -2.0 48.8 44.8 0.00.0U4 0.00.0U3 35.00 PF 14.0 TX PE 0.9 55.00 PV -31.3 0.0 12.9 (N/A) 0.995 PL 150 FTG 0.255 TL Pipe: 107 -2.0 -4.0 0.0 48.8 SRCE 63.7 U4 SRC Page 5 DATE: l/26/2018inklers\Calcs\Initial\2HD - CASITA BEDROOM 1 CALCS FSP.sdf JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS1^-' NOTES (HASS): (1) Calculations were performed by the HASS 8.7 computer program in accordance with NFPA13 (2017) under license no. 38061304 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.097 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 107. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SRC under full flow conditions is 63.97 psi with a flow of 31.38 gpm. (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP HWC: 150 Equivalent Fitting Lengths in Feet PAGE:- F Diameter (in) MATERIAL; CPVC F E T R K C G 45 El Kplg ChkVlv 1.00 1.00 8.00 14.00 Tee RunT 1.00 7.00 5.00 1.00 2.00 9.00 8.00 1.00 Gate 2.00 3.00 1.101 1.598 HWC: 150 Equivalent Fitting Lengths in Feet PAGE; K Diameter (in) MATERIAL: CT-K T F K C GER N X Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee AngVlv 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 14.000.995 HWC: 150 Equivalent Fitting Lengths in Feet PAGE: L Diameter (in) MATERIAL: CT-L E T F R K C G N Ell Tee 45-Ell TeeRun Kouplg ChkVlv GatVlv NPTee 3.00 7.00 1.00 2.00 0.00 7.00 0.00 7.00 4.00 9.00 2.00 3.00 0.50 10.00 0.00 9.00 1.025 1.505 o o > DO HWATER SUPPLY ANALYSIS Static: 64.00 psi Resid: 20.00 psi Flow: 1500.0 gpm w ►.3 •• H3 I-*80.0 t-* PI N>LEGENDAvailable pressure 63.97 psi 0 31.3 gpm1 .. CT^ NJ O CD70.0 H-Required pressure 63.68 psi 0 31.3 gpm s <D h CO W fT3G 60.0 O M(u 2 I-* ^ o t-* CO td A U G HA. Source Supply CurveE 3 CO H- K rt CO H- 0> P]H-> 2 50.0 B. System Demand Curve P R ro a: a: K o aE 40.0S GSO tr*> MuCO n R ►-3 > > Z30.0 E > DO f Rl K O COjd M(O CO op 20.0 s S 1 %n >)t3 O CO10.0 %PI CO rp rp 0) CO iQ a CD% l-h0.0 o^ % -14.7 ?o^00rto ^■0001111 FLOW (GPM) (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source , ItNote: 0 ^ r SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: l/26/2018inklers\Calcs\Initial\2HD - CASITA BEDROOM 1 CALCS FSP.sdf JOB TITLE: WATER SUPPLY CURVE 72+ I I 66+ 0\ X \ \ 60+\\ \ \ \ 54+W \ \ \ WP 48+ \R \E \S WS 42+ \U \R WE 36+\ (\ \P Ws I 30+\ \ \ W 24+\ \ \ * <-20.0 psi @ 1500 gpm Flow Test Point18+ 12+LEGEND X = Required Water Supply 63.68 psi @ 31.3 gpm 6+ 0 = Available Water Supply 63.97 psi @ 31.3 gpm 0++-+ + + +— 400 600 800 1000 1200 1400 FLOW (GPM) 1600 1800 —+ 2000 City of La Quinta Design and Development Department 78-A95 Calle Tampico La Quinta, CA 92253 Telephone: (760)777-7125 Fax: (760)777-1233 www.lo-quinto.orq Riverside County Fire Department Riverside Office 2300 Morket Street. Ste. 150 Riverside, CA 92501 (951)955-4777 OlM mar 3 0 2013 Ijy MP y FIRE REVIEW APPLICATION ^NEW PERMIT NO. 5loll'd?0^5"□ TENANT IMPROVEMENT PROJECT INFORMATION (Pleose Print) V|<\ ?-essc^AD Project Name:■ Sign: Site Address;Print: QaauM , CACity & Zip; • Pursuant to a Cooperative Agreement to Provide Fire Services, the Riverside County Fire Department serves as the City’s tire department, and the County designee serves as the City’s fire chief. Applicant recognizes this contracted arrangement and sholl comply with County Fire Department directions. CONTRACTOR INFORMATION; Same as Applicant infoAPPLICANT/CONTACT INFORMATION flYPApplicant Name:Contractor: Contact P^son;Contact Person: £■ Ort^ihJ Vr ruaj Fax: Mailing Address:Mailing Address: City & Zip:City & Zip: Phone Number;Phone Number:Fax: Email:Email: A. APPLICATION TYPE nRESPMHKLER SYSTEM SUPRESSION SYSTEM □ NEW COMMERCIAL/INDUSTRIAL □ HOOD & DUCT $405 □ 0-35,000 SO FT □ SPRAY BOOTH$639 $795 □ 35,001-75,000 SO FT □ CELL SITE$756 $795 □ 75,001-120,000 SQFT □ OTHER SUPRESSION SYSTEM$951 $795 □ 120,001 AND UP MISC$1185 □ TI COMMERCIAL/INDUSTRIAL 5^^ RESIDENTIAL -1"' DWELLING UNIT □ HAZMAT$405 $327 □ HIGH PILE RACK STORAGE$405 $327 □ RESIDENTIAL - (EA) ADDITIONAL $390 □ NEW COMMERCIAL-U/G WATER $483X □ MULTI-FAMILY (3 OR MORE)□ FIRE FLOW REPORT$561 $327 HRE ALARM SYSTEM □ TECHNICAL REPORT RESEARCH HOURLY (S$156/HR □ COMMERCIAL - SPRINKLER MONITORING □ SPECIAL INSPECTION$405 $161 □ COMMERCIAL - FIRE ALARM SYSTEM □ FIRE PUMPS$1092 $639 FIRE ALARM SYSTEM □ STANDPIPE SYSTEMS $561 □ COMMERCIAL-SPRINKLER MONITORING □ WATER TANKS$405 $390 □ COMMERCIAL-FIRE ALARM SYSTEM $1092 STORAGETANKS □ DISPENSERS ONLY HOURLY @ S156/HR □ ABOVEGROUND HOURLY g>Sl56/HR Fnrh nnnlirnfinn funo inriiirlpi; n Tprhnnlnnv Fnhnnrpmpnt Fpp^R Xi Rprnrf1<; Mnnnnpmpnt Fpp SID