Loading...
CE-18-1655 - 78370 Highway 111, Ste 2804/11/23, 4:56 PM Print Code Enforcement Case Code Enforcement Case: CE -18-1588 L Entered on: 06/26/2018 00:00 Printed on: 04/11/2023 Topic: FIRE Status: Open Due Date: 06/01/20 Assigned To: Kohl Hetrick Initiated bv: Fire Area #: (Select) Permit #: Business name: License #: Property Location Occupant Name: DESERT SALON SUITES Lic: DOB: Address: 78370 HIGHWAY 111 # 280, 92253 Phone: Cell #: APN : 604-050-068 Owner Information Owner Name: Address: Phone: Cell #: _ Actions Action By Date Time Hours Note/Observation FIRE INSPECTION Reyna Camarena 06/26/2018 1:20 pm 0.25 VACANT SUITE FIRE INSPECTION Kohl Hetrick 10/08/2019 0.00 NEW OCCUPANT INSPECTION - FIRE CLEARANCE GRANTED Violations I Violation Type Due Date Status Closed Date Inspection Notes Date: Time: Findings: https://user.govoutreach.com/laquintaca/ceeditcase.php 1 /1 ~ R RSIDE COUNTY FIRE DEPART vT fYt FIRE PROTECTION PLANNING SECTION fA FIRE & LIFE SAFETY NOTICES Inspection Date: a inspection Time: ' Occupancy Class: 43 Inspected By: Utiles c Phone (7c Facility Name: -ay Ga • / Facility Phone: Site Address: 7& - -?,7 O City: .t o t o ,w r State• Zip Owner/Contact Name:, -7;2 r t rte% Co.crrri r Contact Phone: Fag: (+- }- Mailing Address: -- City:.Go �..�...� State: e"ol Zip: Request 1 Roeeived Date 7 - 4 16 Signature of Recipient: x At this time a notice was issued indicating the corrections required to provide compliance with the applicable codes, regulation and ordinances. All items shall be corrected IMMEDIATELY. If you have any questions regarding this information, please contact the Riverside County Fire Department at (760) 863-8886 PREMISES IDENTIFICATION Numbers plainly visible and legible. (CFC 505.1) KNOX ACCESS Xi -ox access at Gate and Main Door. (CFC 506.1) EMERGENCY INFORMATION Emergency Information (CFC 404.2) HYDRANT, FDC, PIV Caps missing. (CFC 508.5.2, 912.6) Obstructions. (CFC 508.5.4) _ Blue Dots. (RCoStandard) Signage. ( CFC 510.1) FIRE APPARATUS ACCESS RQADS _ Red curb or signs. (CFC 503.3) Obstructions (Width 20', Vertical 13'6"). (CFC 503.2.1) FIRE EXTINGUISHERS _ Minimum 2A l OBC. (CFC 906.3) Servicing due. (CFC 906.1) Mounting <5 feet from floor. (CFC 906.9) Obstructions. (CFC 906.6) Commercial kitchen. (CFC 904.1 l.5) FIRE XLARM Serviced (CFC 907.20.5) _ FACP Room Signage (CFC 510.1) AUTOMATIC FIRE SPRINKLER SYSTEMS _ 5 yr. riser/sprinkler servicing. (NFPA 25, Table 5.1) 18" clearance below sprinkler head deflectors. (CFC 315.2.1) Inspectors valve test. (NFPA 13) Sprinkler wrench. (NFPA 13) 6-12 spare sprinkler heads. (NFPA 13) _ Missing escutcheon. (NFPA 13) Riser Room Signage (CFC 510.1) HOOD AND DUCT SYSTEMS Service with in 6 months. (CFC 904.11.6.4) Proper nozzle position, caps, coverage. (NFPA 25, 10.2.5.3) Fusible links, cables, conduits. (CFC 904.11.6.5) Filters/ducts clean. (CFC 904.11.6.3) FLAMMABLE LIQUIDS (CLASS 1, 11, II -A) Approved safety cans. (CFC 3404.3.1.1) Approved cabinets exceeding 10 gals. (CFC 3404.3.4.4) Legible labeling. (CFC 3403.5) _ Placard/NFPA 704 (CFC 3404.2.3.1) Secondary Containment (CFC 3405.3.7.5.3) GENERAL HOUSEKEEPING _ Rubbish/trash buildup. (CFC 304.1) _ Secure pressurized cylinders. (CFC 3003.5.3) Clearance around water heater. (CFC 305.1) - Storage not within 24 inches ceiling. (CFC 315.2.1) Storage under stairs prohibited. (CFC) Storage, use and baudling of combustible materials in attic, under floor & concealed spaces. (CFC 315.2.4) Storage in boiler rooms, mechanical rooms or electrical equipment rooms not allowed. (CFC 315.2.3) WALLS AND CEILING Holes in fire rated walls sealed. (CFC 703.1) Tiles in fire rated ceilings in place and undamaged. (CFC 703.1) EXITS _ Common knowledge hardware. (CFC 1008.1.8) Sign above door stating "This Door To Remain Unlocked When Business Is Occupied. (CFC 1008.1.8.3) _ Illuminated EXIT sign(s) operable. (CFC 1028.4) _ 44" clear access width to exits. (CBC) Exit obstruction. (CFC 1028.3) Maintain fire rated doors, windows, dampers and hardware. (CFC 703.1) Emergency lighting operable. (CFC ) Panic hardware operable. (CFC 1008.1.9) OCCUPANT LIMIT/SIGN Occupant load sign(s) posted. (CFC 1004.3) Required NO SMOKING signs. (CFC 310.3) ELECTRICAL Multiplug adapters not allowed. (CFC 605.4) Circuit breaker panel - Clear and labeled. (CFC 605.3) _ Abatement of electrical hazards. (CFC 605.1) _ Extension cords not allowed as permanent wiring. (CFC 605.5) Outlet faceplate/covers in place. (CFC 605.6) Comments: S -6 -Aa r.eE-'As.�� jb« [i.040740Ar eo Eet6a. T - ,lo 11 C,OUNrI, ' Cf ty�L-•ten � l<' r CLEARED Datem X^ i