TUP 2023-0003 Sol Terra Temporary Generator (07.06.2023)■ ta �W CALIFORNIA July 6, 2023 Mr. David Kinnett Vertical Integrity 917 Glenneyre Street Suite A Laguna Beach, CA 92651 SUBJECT: TEMPORARY USE PERMIT 2023-0003: SOLTERRA RECREATION AND POOL BUILDINGS TEMPORARY GENERATOR Dear Mr. Kinnett: The City of La Quinta Design and Development Department has reviewed and approved Temporary Use Permit (TUP) 2023-0003, for (1) temporary generator located within the Solterra development, subject to the information on file and attached and the following findings and conditions of approval. FINnIN(-o. • The proposal is consistent with the general plan and provisions of the zoning code. The proposal is in compliance with the requirements of the California Environmental Quality Act (CEQA) and would be exempt from CEQA pursuant to Section 15304, Minor Alterations to Land. • The proposal would not create conditions materially detrimental to the public health, safety and general welfare or injurious to or incompatible with other properties or land uses in the vicinity. • The proposed use of the generator is temporary in nature and would be placed in an area consistent with ground mounted equipment in residential areas. The generator is located approximately 300 ft away from the nearest residence and is estimated to generate noise levels under the exterior noise level limits in the Noise section of the zoning code. CONDITIONS OF APPROVAL: 1. The applicant agrees to defend, indemnify and hold harmless the City of La Quinta ("City"), its agents, officers and employees from any claim, action or proceeding to attack, set aside, void, or annul the approval of this Temporary Use Permit. The City shall have sole discretion in selecting its defense counsel. ta �W CALIFORNIA The City shall promptly notify the applicant of any claim, action or procee mg a - cooperate fully in the defense. 2. The generator shall be operated for primary building power 24 -hours a day or at intervals that the building is occupied. At no point should the generator power be turned off or disconnected for more than 24 -hours at which point the building fire alarm system's batteries would be depleted and fail to adequately monitor the fire sprinkler system. 3. The temporary generator may be used until Imperial Irrigation District provides power to the recreation and pool buildings or up to 6 months, whichever comes first. The generator shall be removed within 7 days of either occurrence. 4. A separate building permit shall be required. The City may elect to add Conditions to this application request to mitigate any problems that arise not previously addressed herein. This decision may be appealed to the Planning Commission by any party who submits the necessary paperwork and filing fee of $1,526.00 to this office within 15 days of the date of approval of this permit. If you have any questions, please contact me at (760) 777-7086 or sfernandez(a-)-laguintaca.gov. Sincerely, Sijifredo Fernandez Associate Planner Design and Development Department PLANNING APPROVAL ADMINISTRATIVE CASE# TUP2023-0003 EXHIBIT# INITIAL sfernandez DATE 07/06/2023 4:35:59 PM VERTICAL INTEGRITY TEMPORARY USE PERMIT—APPLICATION INFORMATION DESCRIPTION OF ACTIVITY: Request for Temporary Certificate of Occupancy on the Recreation and Pool Buildings and related amenities. This request is due to having power for these facilities provided by a generator for a temporary period of time. This was necessitated by extraordinary supply chain / lead time issues associated with the electrical switch gear and internal components (that need to be installed prior to I.I.D. pulling in permanent power to the building). The 400a main panel that the generator power will be tied into is the equipment specified on the approved plans for the buildings. The Rec and Pool Buildings, pool area, etc. will be complete at the time we request the TCO (target 7/7/23). All other conditions of occupancy will be met for Building, Fire, Planning, and Public Works. The building occupancies and hours of operation will be as permitted. We will likely run the generator 24 hours a day to maintain the security and fire systems, however we are exploring battery backup for overnight use. Since we do not have solid dates for the permanent power, we request 180 days (we believe it will be a much shorter time frame however). SITF PI AN - The generator will be placed in the location shown on the attached Site Plan. It will be located approximately 1501f from the Rec Building. SUPPLEMENTAL INFORMATION: • Please see attached complete specifications for the generator. The model we have selected is designed to be quiet at 69 dB(A). We discussed an operational site visit, which will hopefully result in not having to prepare a Noise Control Plan or provide any further mitigation. • Please see attached the requested Single Line diagram. • The generator will not be located in the Public Right of Way. Therefore, no traffic control plan has been provided. • The generator will be surrounded by fencing. • Power cords will be in conduit. • Insurance certificates are already on file with the City of La Quinta. 917 Glenneyre Street Suite A Laguna Beach, CA 92651 949-447-0037 www.verticalintegrity.net Mm ELA04 W MR. - M, 21 rur Sm I OMS COM 01, IMF-, A! a 0ion 1 A��:I RVA r�Jj���� 119 _ys Lt; 10 10,31" MN I MI. .14 r1F GENERATOR LOCATION PLAN TO PROVIDE POWER TO REC BUILDING (AND POOL BUILDING) Notes: Red box indicates Generator Location ( appx. 150' away from Rec. Bldg.) Homes adjacent to generator will not be occupied until generator removed. Red line indicates path of power feed (in conduit) to 400a main panel at Rec. Bldg. All Electrical at Rec. Bldg. per approved plans and calculations. 011 I !■■iri■■■#■i■■■■■li1�1i■i� !■■■#■■#■■■■■■■■■#■■■■ _ Y W Noumea "*. sig OMEN 1�."lS1Y##■■■■ 20 ti■■■■■ F I I --ti'■■■■# ■■■moon ■■■ �. ■ WA e3i 1■■�' i##■■■amonommom ■■■■■■i1►'� �1 .fit tfif �� A ir3 aMIN Ro■■■■■■■f■ mom��r. I t u■■■■■■111101 �■� mms k Image ,1111 Iwwwlr■■■ Summ � iiari■�_ i�G I I i■■■ ■■ ■■■omen■#■■1■■ #■■■■■■■■ ■ ■■■■■■■■ ,am_ e1■ �t'�:�+► Il i i, ice` • i • � f i Y I ,� �� 1.�► � � _ �;, 11= - Vii' � t`<I�■i'1aLid.3si• ■3i'�3r�w4:is71:w� _ f'.±fl.�. ■�� ELECTRICAL LOAD 5UMMARY 1. RECREATION CENTER - 3,114 5Q. FT LIGHTING aQ 2.0 VA/5Q. FT X 125% (PER NEC 220.12) = l.q KVA GENERAL POWER a@ 1.0 VA/5Q. FT X 100% (PER NEC, 220.3) = 3.2 KVA KITCHEN EQUIPMENT = 8.8 KVA PATIO HEATERS = 16.0 KVA HVAC SYSTEMS = 43.5 KVA TOTAL =1q.4 KVA OR 220.5A REQUESTED SERVICE: 400A 120/208V 3P 4W 2. POOL BUILDING - 46q 5Q. FT LIGHTING aQ 0.25 VA/5Q. FT X 125% (PER NEC, 220.12) = 0.1 KVA GENERAL POWER a@ 1.0 VA/5Q. FT X 100% (PER NEC, 220.3) = 0.5 KVA HVAC SYSTEMS = 8.4 KVA RESERVED FOR POOL EQUIPMENT = 100A OR 36.0 KVA TOTAL = 45.0 KVA OR 125A REQUESTED SERVICE: 125A 120/208V 3P 4W O ^ �Ln Lu Z� Lu O L (N)120/205 3P 4W FROM UPSTREAM 65KAIG M) (N) (N) 0 341A 3P AIG=40138 (N) PANEL 'A' 82. q KVA 230 A GN (N)200A 3P OR 0 6 u } 0 (N) PANEL 'H' 43.5 KVA 121 A AIG=34331 (N)2"C., 4#2/0 CU. PLUS 1#6 CU. CND. (N)120/205 3P 4W FROM ' '=r,TREAM 41C 12.1 KVA 33.5 A NEMA 3R A '00/// I G=65000 ONO BUS ELECTRICAL 5INGLE LINE NO 5GALE 51NOLE-LINE DIA&RAM GENERAL NOTE5 a) ALL CONDUCTORS SHALL BE COPPER A5 FOLLOWS: #12 AWG AND SMALLER - SOLID, TW #10 AWG AND LARGER - STRANDED, THWN, THHN OR XHHW ALL CONDUCTORS SIZES ARE BASED ON l8 G TEMPERATURE RATING (NEC. 2011 TABLE 310.16) b) ALL NEW CIRCUIT BREAKERS, FUSIBLE 5WITGHE5 IN MAIN SWITCHBOARD OR PANEL BOARDS SHALL BE SERIES RATED TO MATCH EXISTING AIG RATING OR APPROVED EQUAL OR 65KAIC, UNLE55 NOTED OTHERWISE. c) MOTOR CIRCUIT PROTECTORS SHALL NOT BE A PART OF A SERIES COMBINATION INTERRUPTING RATING. d) SERIES COMBINATION AIG RATING SHALL NOT BE USED WHEN THE SECONDARY EQUIPMENT IN THE SERIES 15 SUBJECTED TO A TOTAL CONNECTED FULL LOAD MOTOR CURRENT OF MORE THAN 1 % OF ITS AIG RATING. e) EQUIPMENT ENCLOSURES SHALL BE CLEARLY MARKED "CAUTION-5ERIE5 RATED SYSTEM - 65KAMP5 AVAILABLE, IDENTIFIED REPLACEMENT COMPONENTS REQUIRED", IN COMPLIANCE WITH 2O1q GEC (2011 NEC) SECTION 110-22. END USE EQUIPMENT SHALL AL50 BE MARKED WITH THE HIGHER SERIES COMBINATION INTERRUPTING RATING A5 PER 201q GEC SECTION 240-b3(C). NO EXCEPTION. f) FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS. g) ELECTRICAL EQUIPMENT SHALL BE L15TED BY THE CITY, WHERE THE PROJECT 15 LOCATED, RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. h) NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT PER 110.26(E)(1). CONTRACTOR TO TAKE CARE TO MAINTAIN ALL CLEARANCES A5 REQUIRED BY 110.26(A) -(E) IN ALL INSTALLATIONS. i) MAIN SERVICE WILL NOT BE ENERGIZED PRIOR TO THE BUILDING INSPECTORS RECEIPT OF A THIRD PARTY "NRTL" TESTING LABORATORY PERFORMAGE TEST CERTIFICATION FOR THE SERVICE GROUND FAULT PROTECTION 2011 NEC, 230A5 j) ARG FLASH WARNING LABELS ON SWITCHBOARDS SHALL BE PROVIDED IN ACCORDANCE WITH CEG 110.16. 51NGLE DIAORAM KEYED NOTE5 O THE EQUIPMENT SHOWN 15 EXISTING UNDER A PREVIOUS APPROVED CONSTRUCTION PERMIT, NOT A PART OF TH15 SUBMITTAL, UNLE55 NOTED A5 NEW. 0 3/4"G., 1#3/0 CND. THE CONNECTION SHALL BE MADE WITHIN THE FIRST FIVE FEET OF THE WATER PIPE ENTRANCE TO THE BUILDING. 03 3/4"0., 1#3/0 CND. TO BUILDING FOOTERFOUNDATION REINFORCING 5TEEL. SWITCHBOARD SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE MAXIMUM ® AVAILABLE FAULT CURRENT. THE FIELD MARKINGS SHALL INCLUDE THE DATE THE FAULT -CURRENT CALCULATIONS WA5 PERFORMED. [CEG 1 10.2(A)] 05 MAIN SERVICE DISCONNECT SHALL BE MARKED PERMANENTLY. [GEG 230.1003)] CDGor_ I li I I I I LU z Lu J LU Z -1 Lu ks) 46-3 Lu m s 0 � � V m 0 w cl 0 z_ a 0 DATE: 6/22/23 SCALE: NO SCALE SHEET: z O a w 0 w} J m m Q � W z� O> w w 0 �w > � Q Lu m z G 12SRS I Rental Diesel Generator ■ DIESEL GENERATOR ELECTRICA Frequency (Hz) Phases Voltage M 60 3 480277V 60 3 208/120V 60 1 240V T4F JCB WEIGHT AND DIMENSIONS - STATIC Length in 126 Width in 43 Height in 83 Weight* lbs 6615 *Standard build with all fluids including fuel Emissions EIGHT AND DIMENSIONS - TRAILER MOUNTED - Length in 189 Width in 74 Height in 105 Weight* lbs 8115 'Standard build with all Auids including fuel 66 Prime Rating kVA kW Amps Rated Speed (RPM) Emissions 125 100 151 1800 T4F 125 100 347 1800 T4F 66 66 275 1800 T4F POWER FACTOR _ 3 Phase 0.8 1 Phase I ALL RATINGS ARE TO STANDARD REFERENCE CONDITIO Prime: This rating is for the supply of continuous electrical power, at variable load (70% average), in lieu of commercially purchase power. There is no limitation on the annual hours of operation and 10% over load power can be supplied for I hour in 12. Ambient reference conditions I000mbar, 25°C, 30% relative humidity IS03046 JCB GENERATOR TECHNICAL SPECIFICATIONS. JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories. G 125Rs EN — Provisional Issue: 11 /092020 1 1:40:53 G 12SRS I Rental Diesel Generator RISE—] AIR SYSTEM ENGINE Limiting Ambient Temperature of 124 1800 RPM Radiator Duct Allowance In H2O 60Hz TBC Net Output Rating (PRP) kW 106 Radiator Cooling Airflow cfm 10594 Net Output Rating (Standby) kW 1 17 EXHAUST SYSTEM ' Manufacturer and Model JCB JCB 448 TA4-129 Maximum Temperature 100% of TBC Fuel Diesel Exhaust Gas Flow 100% Ibs/hr 60Hz 1387 Injection Common Rail Maximum Allowed Back Pressure In H2O 100 Aspiration Turbo Charged Cylinders 4 FUEL SYSTEM Bore and Stroke in 4.2 x 5.3 Diesel Specification Grade ASTM D975 (2D) Displacement in3 291.0 Cooling Water Standard Fuel Tank Capacity (US) g 132 Engine Oil Specification API CH4-SAE I OW40 Fuel Tank Material Type Steel Compression Ratio 16,7: I Fuel Tank Construction Double Skinned Engine Oil Capacity (US) g 4.00 Coolant Capacity (US) g 4.2 FUEL CONSUMPTION Governor Electronic 100% Load Prime (US) gph 7.16 Engine Oil Consumption (US) gph 0.004 75% Load Prime (US) gph 60Hz 5.42 SCR • 50% Load Prime (US) gph 3.70 Exhaust After treatment DOC x DPF x DEF SYSTEM DEF Specification ISO 22241-1 AMB%&LLEARAICE Standard Capacity Tank (US) g 4.5 Upper Temperature Limit OF 122 Lower Temperature Limit OF 23 DEF CONSUMPTION 100% Load Prime (US) gph 0.25 SOUND PRESSURE No 75% Load Prime (US) gph 60Hz 0.19 LpA (23ft & 100% load) dB(A) 60Hz 69 50% Load Prime (US) gph 0.13 JCB GENERATOR TECHNICAL SPECIFICATIONS. JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories. G 125Rs EN - Issued: 1 1/09/2020 11:40:53 G 12SRS I Rental Diesel Generator ELECTRICAL - AVR DSR AVR DERI with 3 phase sensing Total + Winding Protection for Harsh & Saline Environments MAUX – High Motor Start Auxiliary Winding Anti -Condensation Heater 3 Pole Moulded Case Circuit Breaker Earth Leakage Protection (Switchable) Preparation for Earth Spike Emergency Stop Button (Control Panel) 120V Charger & Heater Supply Sockets GFCI 120V Small Power Sockets 50A Shore Power Sockets Camlock Connections Terminal Safety Microswitches Standard: • Not Available: x Optional: A i • A A • A A A A • BATTERY FEATURES Battery Isolator • Battery Type Maintenance Free Lead Acid Battery Charger – I OA A STARTING SYSTEM Battery Capacity Ah 1000 Number of Batteries I Auxiliary Voltage V 12 ALTERNATOR ECP34-1 L/4A WK Poles 4 Insulation Class H Enclosure IP23 Exciter System MAUX Excitation Voltage Regulator AVR - DSR Steady State Voltage Regulation +/- I% Bearing Single bearing sealed Coupling Flexible disc Cooling Direct drive centrifugal blower fan Coating Total Protection + Multi Position Voltage Selection Switch A Standard: • Not Available: x Optional: A CONTROL AND COMMUNICATION DSE 7310 (Non Sync) Controller • DSE 8610 (Sync) Controller (> 220 with DSE8003 colour screen) A Deif AGC 150 (Non Sync) Controller A Deif AGC4 (Sync) Controller with TDU7 Touchscreen Display x Analogue Load Share A External USB Programmable Port A JCB LiveLink for Power • High Engine Temperature Shutdown • Low Oil Pressure Shutdown • Low Coolant Level Alarm • Leak Detection Alarm A Analogue Hour Counter A Bus Live Warning Lamp • Audible Alarm Sounder • Panel Mounted Voltage Trimpot A Standard: • Not Available: x Optional: A JCB GENERATOR TECHNICAL SPECIFICATIONS. JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories. G 125RS EN -Issued: 11/09/2020 1 1:40:53 G 12SRS I Rental Diesel Generator MECHANICAL - Tropical Cooling Pack • Heavy Duty Air Filter • Radiator Fan Guards • Hot Component Guards • Manual Oil Drain Pump A Water Jacket Heater A Fuel Pre -Filter with Separator • Racor water/fuel separator A Racor change over water/fuel separator x Fuel Level Sender • 3 Way Fuel Valve A Exhaust Silencer including Aftertreatment • Fuel Tank Access Plate • External Fuel and DEF Fill Point • Remote DEF Tank Connection A Standard: • Not Available: x Optional: A TRAILER - Optional DOT Approval • LED Lights • Electric Brakes • Access Platform Fenders • 3" Pintle Eye Hitch • 7 Pin Towing Electrics • Tie Down Points • Heavy Duty Jack • Fire Extinguisher A Black Paint Finish (Trailer & Rims) • Standard: • Not Available: x Optional: A CANOPY Lockable Maintenance Access Doors Control Panel Viewing Window Single Lift Point Fork Lift Pockets Fluid Containment with Drain Point 4 Point Tie Down High Density Fire Retardant Foam Yellow Paint Other Paint Finishes Heavy Duty Rental Base Zintec Steel Canopy Integrated High Level Access Ladder Self -Latching Cable Access Points Door Retention Catches External Emergency Stop Button Waterproof Document Holder Standard: • Not Available: x JCB GENERATOR TECHNICAL SPECIFICATIONS. JCB reserves the right to change specifications without notice. Illustrations shown may include optional equipment and accessories. JCB Optional: A G 125Rs EN - Issued: 1 1/09/2020 11:40:53