Loading...
SP 2001-051 Preliminary Hydrology Report (2001)VISTA MONTANA PRELIMINARY HYDROLOGY REPORT January 17, 2001 PREPARED BY: MDS Consulting Planners * Engineers * Surveyors 17320 Redhill Avenue, Suite 350 Irvine, CA 92614 Phone 949/ 251-8821 Fax 949/ 251-0516 Morse Dokich Schultz 7 D 0 K I C H 1,-u, CA 92614 tieFr, no J.�' WC 1 r.Tn� a PLANNERS ENGINEERS SURVEYORS CALI Da te [File: G:\513\28\VISTAMONTANA.doc] 1/17/01 ti ON INDEX • Pro`ect Desci tion f Narrative Section A: Hydrology Calculation 1. Q100 Hydrology Calculation 2. Hydrology Map for Rational Method Analysis Section B: Unit Hydrograph Calculation 1. Q100 / 24 Hour 2. Hydrology Map for Unit Hydrograph Analysis PROJECT DESCRIPTION / NARRATIVE The following hydrologic analysis is provided for preliminary justification ofstorm drain improvements proposed for the Vista Montana General Man Amendment, Zone Change, Specific Plan, and Village Use Permit in the City of La Quita, County of Riverside, State of California. The site is currently used for agricultural purposes. Current drainage is in a northerly / northeasterly direction via over land sheet flow. The site slopes at approximately 0.5% undulates due to crop rows. Proposed storm drain improvements will provide 100 year runoff retention on site. Residential area storm drain storage will be provided above the base water surface elevation of the lake located in the center of the project and below curb flow line of the surrounding streets. Commercial areas runoff retention will be provided within the individual commercial lots. Commercial retention is anticipated within landscape area depressions, leach fields or a combination thereof. Storni drain improvements will consist of several storm drain fines internal to the project with off site storm drain improvement within Eisenhower Drive. Each line will be fitted with a bubbler to prevent lake waters from backflowing into the system and drywells to collect nuisance flows prior to entering the lake. Storm drain Rational Meted and Unit Hydrograph analysis is prepared using AES modeling software for Riverside County. SECTION A r` fY� { •r RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (1 (RCFC&WCD) 1978 HYDROLOGY MANUAL (* (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: C, MDS CONSULTING (1 17320 REDHILL AVENUE SUTIE 350 ( IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA A ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:38 01/18/2001 USER-SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: FUSER -SPECIFIED -STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) y-1 30.0 - u20.0 - 0.018/0.018/0.020 -0.67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ->> >>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 599.40 UPSTREAM ELEVATION = 44.00 DOWNSTREAM ELEVATION = 42.00 ELEVATION DIFFERENCE = 2.00 TC = 0.359*[( 599.40**3)/( 2.00)]**.2 = 14.513 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.697 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7633 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 3.67 TOTAL AREA(ACRES) = 1.30 TOTAL RUNOFF(CFS) = 3.67 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 1.30 TC (MIN.) = 14.51 PEAK FLOW RATE(CFS) = 3.67 END OF RATIONAL METHOD ANALYSIS 1 C, **************************************************************************** RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA B ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:39 01/18/2001 ----------------------------------------------------------------------------- USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ----------------------------------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 ^30.0 r -20.0 0.018/0.018/0.020 0.67` 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 - >> >>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 201.00 1 l l l 1 l 1 l 1. l l 1, UPSTREAM ELEVATION = 43.00 DOWNSTREAM ELEVATION = 42.00 ELEVATION DIFFERENCE = 1.00 TC = 0.359*L( 201.00**3)/( 1.00)]**.2 = 8.655 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.015 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7863 (� SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 3.15 TOTAL -RUNOFF(CFS)-=------3_15------------- --TOTAL -AREA(ACRES)-=------080--- END OF STUDY SUMMARY: F` TOTAL AREA(ACRES) = 0.80 TC(MIN.) = 8.65 PEAK FLOW RATE(CFS) = 3.15 ( END OF RATIONAL METHOD ANALYSIS 1 l l l 1 l 1 l 1. l l 1, RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: C, MDS CONSULTING C, 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * AREA C ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:34 01/18/2001 - USER SPECIFIED HYDROLOGY AND - HYDRAULIC MODEL INFORMATION: USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 c20.0 0.018/0.018/0.020 ^0.67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 __>> >>>RATIONAL -METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 200.00 UPSTREAM ELEVATION = 43.00 DOWNSTREAM ELEVATION = 42.00 ELEVATION DIFFERENCE = 1.00 TC = 0.359*[( 200.00**3)/( 1.00)]**.2 = 8.629 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.024 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7864 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 7.90 TOTAL AREA(ACRES) = 2.00 TOTAL RUNOFF(CFS) = 7.90 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 2.00 TC(MIN.) = 8.63 PEAK FLOW RATE(CFS) = 7.90 END OF RATIONAL METHOD ANALYSIS 1 RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA D ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:36 01/18/2001 ----------------------------------------------------------------------------- USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ---------------------------------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) _-1 30.0 20.0 0.018/0.018/0.020 0 67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 >> >>>RATIONAL -METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 687.20 UPSTREAM ELEVATION = 45.50 DOWNSTREAM ELEVATION = 42.00 ELEVATION DIFFERENCE = 3.50 TC = 0.359*[( 687.20**3)/( 3.50)]**.2 = 14.086 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.762 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7647 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 11.80 TOTAL AREA(ACRES) = 4.10 TOTAL RUNOFF(CFS) = 11.80 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 4.10 TC(MIN.) = 14.09 (' PEAK FLOW RATE(CFS) = 11.80 END OF RATIONAL METHOD ANALYSIS � 1 C (, RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA E ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:41 01/18/2001 `USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: USER SPECIFIEDSTORMEVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 20.0 0.018/0.018/0.020 0 67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth) * (Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 328.50 UPSTREAM ELEVATION = 45.20 DOWNSTREAM ELEVATION = 43.50 ELEVATION DIFFERENCE = 1.70 TC = 0.359*[( 328.50**3)/( 1.70)]**.2 = 10.451 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.487 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7781 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 6.63 TOTAL AREA(ACRES) = 1.90 TOTAL RUNOFF(CFS) = 6.63 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 1.90 TC(MIN.) = 10.45 PEAK FLOW RATE(CFS) = 6.63 END OF RATIONAL METHOD ANALYSIS 1 **************************************************************************** RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA F ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:43 01/18/2001 vUSER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ------------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE -OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 -- 20.0 0.018/0.018/0.020 -0.67- 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 338.30 UPSTREAM ELEVATION = 45.20 DOWNSTREAM ELEVATION = 43.50 ELEVATION DIFFERENCE = 1.70 TC = 0.359*[( 338.30**3)/( 1.70)]**.2 = 10.637 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.440 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7773 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 3.11 TOTAL AREA(ACRES) = 0.90 TOTAL RUNOFF(CFS) = 3.11 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 0.90 TC(MIN.) = 10.64 PEAK FLOW RATE(CFS) = 3.11 END OF RATIONAL METHOD ANALYSIS l l l l l t l RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA H ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 09:44 01/18/2001 --------------------------------------------------- USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ---------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 T20.0� 0.018/0.018/0.020 0.67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ------------------------------------------------------------------ >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS CONDOMINIUM TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 544.60 UPSTREAM ELEVATION = 44.00 DOWNSTREAM ELEVATION = 41.40 ELEVATION DIFFERENCE = 2.60 TC = 0.359*[( 544.60**3)/( 2.60)]**.2 = 13.001 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.944 CONDOMINIUM DEVELOPMENT RUNOFF COEFFICIENT = .7683 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 4.85 TOTAL AREA(ACRES) = 1.60 TOTAL RUNOFF(CFS) = 4.85 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 1.60 TC(MIN.) = 13.00 PEAK FLOW RATE(CFS) = 4.85 END OF RATIONAL METHOD ANALYSIS 1 RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA J ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 10:11 01/18/2001 USER SPECIFIEDHYDROLOGYAND HYDRAULIC MODEL INFORMATION: ---------------------------------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 -20.0 0.018/0.018/0.020 -0.67f 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS COMMERCIAL TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 323.10 1 UPSTREAM ELEVATION = 44.00 DOWNSTREAM ELEVATION = 42.40 ELEVATION DIFFERENCE = 1.60 TC = 0.303*L( 323.10**3)/( 1.60)1**.2 = 8.838 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.953 COMMERCIAL DEVELOPMENT RUNOFF COEFFICIENT = .8673 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 4.30 TOTAL AREA(ACRES) = 1.00 TOTAL RUNOFF(CFS) = 4.30 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 1.00 TC (MIN.) = 8.84 PEAK FLOW RATE(CFS) = 4.30 ---------------------------------- ___________________________________________________________________________ END OF RATIONAL METHOD ANALYSIS 1 RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL n (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING C 17320 REDHILL AVENUE SUTIE 350 C, IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA L ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 10:09 01/18/2001 USER-SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ---------------------------------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 20.0 0.018/0.018/0.020 0 67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS COMMERCIAL TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 276.20 UPSTREAM ELEVATION = 42.90 DOWNSTREAM ELEVATION = 41.50 ELEVATION DIFFERENCE = 1.40 TC = 0.303*[( 276.20**3)/( 1.40)1**.2 = 8.262 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.154 COMMERCIAL DEVELOPMENT RUNOFF COEFFICIENT = .8681 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 5.82 TOTAL AREA(ACRES) = 1.30 TOTAL RUNOFF(CFS) = 5.82 END OF STUDY SUMMARY: TOTAL AREA (ACRES ) = 1.30 TC (MIN . ) = 8.26 PEAK FLOW RATE(CFS) = 5.82 END OF RATIONAL METHOD ANALYSIS 1 RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON 0101 RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) (` Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING C 17320 REDHILL AVENUE SUTIE 350 (' IRVINE CA. 92614 f 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** ( * TENTATIVE TRACT NO. 29858 f * DEVELOPED HYDROLOGY - RATIONAL METHOD f * AREA K f************************************************************************** f ( FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 10:06 01/18/2001 - (________________________________________________________ ( USERSPECIFIED -HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ------------------------------- ( USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 ( 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 c COMPUTED RAINFALL INTENSITY DATA: ( STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 ( RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD ( NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL ( AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES ( *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* ( HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 820.0^ 0.018/0.018/0.020 0.67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* t **************************************************************************** ( FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ____________________________________________________ >> >>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS COMMERCIAL TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 463.50 l l UPSTREAM ELEVATION = 40.70 DOWNSTREAM ELEVATION = 38.40 ELEVATION DIFFERENCE = 2.30 TC = 0.303*[( 463.50**3)/( 2.30)]**.2 = 10.206 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.550 COMMERCIAL DEVELOPMENT RUNOFF COEFFICIENT = .8655 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 13.78 TOTAL AREA(ACRES) = 3.50 TOTAL RUNOFF(CFS) = 13.78 **************************************************************************** FLOW PROCESS FROM NODE 2.00 TO NODE 2.00 IS CODE = 1 >>>>>DESIGNATEyINDEPENDENT STREAM FOR CONFLUENCE« <<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE: TIME OF CONCENTRATION(MIN.) = 10.21 RAINFALL INTENSITY(INCH/HR) = 4.55 TOTAL STREAM AREA(ACRES) = 3.50 PEAK FLOW RATE(CFS) AT CONFLUENCE = 13.78 **************************************************************************** FLOW PROCESS FROM NODE 3.00 TO NODE 2.00 IS CODE = 21 >> >>>RATIONAL -METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS COMMERCIAL TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 680.00 UPSTREAM ELEVATION = 42.30 DOWNSTREAM ELEVATION = 38.40 ELEVATION DIFFERENCE = 3.90 TC = 0.303*[( 680.00**3)/( 3.90)]**.2 = 11.558 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.228 COMMERCIAL DEVELOPMENT RUNOFF COEFFICIENT = .8639 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 15.34 TOTAL AREA(ACRES) = 4.20 TOTAL RUNOFF(CFS) = 15.34 **************************************************************************** FLOW PROCESS FROM NODE 2.00 TO NODE 2.00 IS CODE = 1 >> >>>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE« <<< >> >>>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES<< <<< TOTAL NUMBER OF STREAMS = 2 CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE: TIME OF CONCENTRATION(MIN.) = 11.56 RAINFALL INTENSITY(INCH/HR) = 4.23 TOTAL STREAM AREA(ACRES) = 4.20 PEAK FLOW RATE(CFS) AT CONFLUENCE = 15.34 ** CONFLUENCE DATA ** STREAM RUNOFF Tc INTENSITY AREA NUMBER (CFS) (MIN.) (INCH/HOUR) (ACRE) 1 13.78 10.21 4.550 3.50 2 15.34 11.56 4.228 4.20 *********************************WARNING********************************** IN THIS COMPUTER PROGRAM, THE CONFLUENCE VALUE USED IS BASED ON THE RCFC&WCD FORMULA OF PLATE D-1 AS DEFAULT VALUE. THIS FORMULA WILL NOT NECESSARILY RESULT IN THE MAXIMUM VALUE OF PEAK FLOW. ************************************************************************** RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO CONFLUENCE FORMULA USED FOR 2 STREAMS. ** PEAK FLOW RATE TABLE ** STREAM RUNOFF Tc INTENSITY NUMBER (CFS) (MIN.) (INCH/HOUR) 1 27.33 10.21 4.550 2 28.15 11.56 4.228 COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS: PEAK FLOW RATE(CFS) = 28.15 Tc(MIN.) = 11.56 TOTAL AREA(ACRES) = 7.70 LONGEST FLOWPATH FROM NODE 3.00 TO NODE 2.00 = 680.00 FEET. END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 7.70 TC(MIN.) = 11.56 PEAK FLOW RATE(CFS) = 28.15 END OF RATIONAL METHOD ANALYSIS 1 **************************************************************************** RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA M ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 10:14 01/18/2001 --------------------------------------------------- USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION: ---------------------------------------------------------------------------- USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) -^1 30.0 20.0 0.018/0.018/0.020 0.67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS COMMERCIAL TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 803.50 UPSTREAM ELEVATION = 55.60 DOWNSTREAM ELEVATION = 44.50 ELEVATION DIFFERENCE = 11.10 TC = 0.303*[( 803.50**3)/( 11.10)]**.2 = 10.364 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.509 COMMERCIAL DEVELOPMENT RUNOFF COEFFICIENT = .8653 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 8.58 TOTAL AREA(ACRES) = 2.20 TOTAL RUNOFF(CFS) = 8.58 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 2.20 TC(MIN.) = 10.36 PEAK FLOW RATE(CFS) = 8.58 END OF RATIONAL METHOD ANALYSIS 1 RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM BASED ON RIVERSIDE COUNTY FLOOD CONTROL & WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1982-99 Advanced Engineering Software (aes) Ver. 1.5A Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING 17320 REDHILL AVENUE SUTIE 350 IRVINE CA. 92614 949-251-8821 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 29858 * DEVELOPED HYDROLOGY - RATIONAL METHOD * * AREA N ************************************************************************** FILE NAME: HYDRO-A.DAT TIME/DATE OF STUDY: 10:48 01/18/2001 - USER fSPECIFIED -HYDROLOGY AND HYDRAULIC MODEL INFORMATION: -USER SPECIFIED STORM EVENT(YEAR) = 100.00 SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00 SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = 0.95 2 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 0.500 100 -YEAR, 1 -HOUR PRECIPITATION(INCH) = 1.600 COMPUTED RAINFALL INTENSITY DATA: STORM EVENT = 100.00 1 -HOUR INTENSITY(INCH/HOUR) = 1.600 SLOPE OF INTENSITY DURATION CURVE = 0.5900 RCFC&WCD HYDROLOGY MANUAL "C" -VALUES USED FOR RATIONAL METHOD NOTE: COMPUTE CONFLUENCE VALUES ACCORDING TO RCFC&WCD HYDROLOGY MANUAL AND IGNORE OTHER CONFLUENCE COMBINATIONS FOR DOWNSTREAM ANALYSES *USER -DEFINED STREET -SECTIONS FOR COUPLED PIPEFLOW AND STREETFLOW MODEL* HALF- CROWN TO STREET-CROSSFALL: CURB GUTTER -GEOMETRIES: MANNING WIDTH CROSSFALL IN- / OUT -/PARK- HEIGHT WIDTH LIP HIKE FACTOR NO. (FT) (FT) SIDE / SIDE/ WAY (FT) (FT) (FT) (FT) (n) 1 30.0 20.0 0.018/0.018/0.020 -0.67 2.00 0.0313 0.167 0.0150 GLOBAL STREET FLOW -DEPTH CONSTRAINTS: 1. Relative Flow -Depth = 0.00 FEET as (Maximum Allowable Street Flow Depth) - (Top -of -Curb) 2. (Depth)*(Velocity) Constraint = 6.0 (FT*FT/S) *SIZE PIPE WITH A FLOW CAPACITY GREATER THAN OR EQUAL TO THE UPSTREAM TRIBUTARY PIPE.* **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 21 ---------------------------------------------------------------------------- >>>>>RATIONAL METHOD INITIAL SUBAREA ANALYSIS<< <<< ASSUMED INITIAL SUBAREA UNIFORM DEVELOPMENT IS COMMERCIAL TC = K*[(LENGTH**3)/(ELEVATION CHANGE)]**.2 INITIAL SUBAREA FLOW -LENGTH = 164.60 1 A� UPSTREAM ELEVATION = 44.00 DOWNSTREAM ELEVATION = 43.20 ELEVATION DIFFERENCE = 0.80 TC = 0.303*[( 164.60**3)/( 0.80)]**.2 = 6.774 100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.795 COMMERCIAL DEVELOPMENT RUNOFF COEFFICIENT = .8704 SOIL CLASSIFICATION IS "A" SUBAREA RUNOFF(CFS) = 0.50 TOTAL AREA(ACRES) = 0.10 TOTAL RUNOFF(CFS) = 0.50 END OF STUDY SUMMARY: TOTAL AREA(ACRES) = 0.10 TC(MIN.) = 6.77 PEAK FLOW RATE(CFS) = 0.50 END OF RATIONAL METHOD --------------------------- ANALYSIS 1 1./51328/HYDRO/RATIONAL. DWG 1-17-01 SECTION B **************************************************************************** F L 0 0 D R O U T I N G A N A L Y S I S ACCORDING TO RIVERSIDE COUNTY FLOOD CONTORL AND WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1989-99 Advanced Engineering Software (aes) Ver. 7.0 Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING Planners * Engineers * Surveyors 17320 Redhill Avenue, Suite 350 Irvine, CA 92614 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 30043 * Q100 / 24 HOURS STORM * AREA GC1 ************************************************************************** FILE NAME: C:\AES99\HYDROSFT\FLOODX\30043\30043UH.100 TIME/DATE OF STUDY: 17:08 01/16/2001 **************************************************************************** FLOW PROCESS FROM NODE 1.00 TO NODE 2.00 IS CODE = 1 ---------------------------------------------------------------------------- »»>SUBAREA RUNOFF (UNIT-HYDROGRAPH ANALYSIS) ««< (UNIT-HYDROGRAPH ADDED TO STREAM #1) WATERCOURSE LENGTH = 1000.000 FEET LENGTH FROM CONCENTRATION POINT TO CENTROID = 500.000 FEET ELEVATION VARIATION ALONG WATERCOURSE = 8.500 FEET BASIN FACTOR = 0.015 WATERSHED AREA = 20.000 ACRES BASEFLOW = 0.000 CFS/SQUARE-MILE WATERCOURSE "LAG" TIME = 0.038 HOURS CAUTION: LAG TIME IS LESS THAN 0.50 HOURS. THE 5 -MINUTE PERIOD UH MODEL (USED IN THIS COMPUTER PROGRAM) MAY BE TOO LARGE FOR PEAK FLOW ESTIMATES. DESERT S -GRAPH SELECTED UNIFORM MEAN SOIL-LOSS(INCH/HOUR) = 0.065 LOW SOIL -LOSS RATE PERCENT(DECIMAL) = 0.850 MINIMUM SOIL -LOSS RATE(INCH/HOUR) = 0.032 USER -ENTERED RAINFALL = 5.00 INCHES RCFC&WCD 24 -Hour Storm (15 -Minute period) SELECTED RCFC&WCD DEPTH -AREA ADJUSTMENT FACTOR(PLATE E-5.8) = 1.0000 UNIT HYDROGRAPH TIME UNIT = 15.000 MINUTES UNIT INTERVAL PERCENTAGE OF LAG -TIME = 659.357 RUNOFF HYDROGRAPH LISTING LIMITS: MODEL TIME(HOURS) FOR BEGINNING OF RESULTS = 10.00 MODEL TIME(HOURS) FOR END OF RESULTS = 18.00 - --------------------------------------------------------- UNIT HYDROGRAPH DETERMINATION ---------------------------------------------------------------------------- INTERVAL "S" GRAPH UNIT HYDROGRAPH NUMBER ---------------------------------------------------------------------------- MEAN VALUES ORDINATES(CFS) 1 77.601 62.566 2 99.887 17.969 3 99.955 0.055 4 99.989 0.027 5 100.000 0.009 TOTAL STORM RAINFALL(INCHES) = 5.00 TOTAL SOIL-LOSS(INCHES) = 1.41 TOTAL EFFECTIVE RAINFALL(INCHES) = 3.59 ---------------------------------------------------------------------------- TOTAL SOIL -LOSS VOLUME(ACRE-FEET) = 2.3457 TOTAL STORM RUNOFF VOLUME(ACRE-FEET) = 5.9843 ---------------------------------------------------------------------------- 2 4- H O U R S T O R M R U N O F F H Y D R 0 G R A P H ' HYDROGRAPH IN FIVE-MINUTE --------------- UNIT INTERVALS(CFS) (Note: Time indicated is at END of Each Unit Intervals) --------------------- TIME(HRS) VOLUME(AF) t-------------------__-----------------_--------------------------_-------------- ---------------------------------------- Q(CFS) 0. 5.0 10.0 15.0 20.0 i 10.083 1.6535 5.30 QV 4 10.167 1.6900 5.30 QV 10.250 1.7266 5.30 QV i 10.333 1.7589 4.69 Q.V �. 10.417 1.7912 4.69 Q.V 10.500 1.8236 4.69 Q. V 10.583 1.8668 6.28 Q ° 10.667 1.9100 6.28 Q 10.750 1.9532 6.28 QV 10.833 1.9997 6.74 Q 10.917 2.0462 6.74 Q 11.000 2.0926 6.74 Q s 11.083 2.1370 6.45 Q V 11.167 2.1815 6.45 Q V 11.250 2.2259 6.45 Q V 11.333 2.2699 6.38 Q V 11.417 2.3138 6.38 Q V 11.500 2.3578 6.38 Q V 11.583 2.3976 5.78 .Q V s 11.667 2.4373 5.78 Q V 11.750 2.4771 5.78 Q V 11.833 2.5179 5.93 Q V 11.917 2.5587 5.93 Q V 12.000 2.5996 5.93 Q V 12.083 2.6562 8.22 QV 12.167 2.7129 8.22 Q V 12.250 2.7695 8.22 Q V . 12.333 2.8327 9.18 Q . 12.417 2.8960 9.18 QV. 12.500 2.9593 9.18 QV. 12.583 3.0276 9.92 QV 12.667 3.0959 9.92 QV 12.750 3.1642 9.92 Q V 12.833 3.2361 10.43 QV 12.917 3.3079 10.43 Q V 13.000 3.3797 10.43 Q V 13.083 3.4631 12.10 VQ 13.167 3.5465 12.10 VQ 13.250 3.6298 12.10 Q 13.333 3.7164 12.57 VQ 13.417 3.8030 12.57 Q 13.500 3.8896 12.57 Q 13.583 3.9526 9.15 Q , V 13.667 4.0156 9.15 Q V 13.750 4.0786 9.15 Q V 13.833 4.1349 8.18 Q V 13.917 4.1913 8.18 Q V . 14.000 4.2476 8.18 Q V . 14.083 4.3126 9.44 Q V . 14.167 4.3777 9.44 Q V. 14.250 4.4427 9.44 Q V. 14.333 4.5082 9.51 Q. V 14.417 4.5736 9.51 Q. V 14.500 4.6391 9.51 Q. V 14.583 4.7041 9.43 Q V 14.667 4.7690 9.43 Q V 14.750 4.8340 9.43 Q , V 14.833 4.8969 9.14 Q V 14.917 4.9598 9.14 Q V 15.000 5.0227 9.14 Q V 15.083 5.0830 8.75 Q V 15.167 5.1432 8.75 Q V 15.250 5.2035 8.75 Q V 15.333 5.2611 8.36 Q V 15.417 5.3187 8.36 Q V 15.500 5.3763 8.36 Q V 15.583 5.4247 7.04 Q V 15.667 5.4732 7.04 Q V 15.750 5.5216 7.04 Q V 15.833 5.5677 6.69 Q V 15.917 5.6138 6.69 Q V 16.000 5.6599 6.69 Q V 16.083 5.6737 2.01 Q V 16.167 5.6876 2.01 Q V , 16.250 5.7014 2.01 Q V . 16.333 5.7061 0.68 Q V . 16.417 5.7108 0.68 Q V . 16.500 5.7155 0.68 .Q V . 16.583 5.7180 0.38 Q V . 16.667 5.7206 0.38 Q V . 16.750 5.7232 0.38 Q V 16.833 5.7253 0.30 Q V . 16.917 5.7273 0.30 Q V . 17.000 5.7294 0.30 Q V . 17.083 5.7358 0.94 Q V . 17.167 5.7423 0.94 Q V . 17.250 5.7487 0.94 Q V . 17.333 5.7565 1.13 Q V , 17.417 5.7643 1.13 Q V . 17.500 5.7720 1.13 Q V . 17.583 5.7799 1.14 Q V . 17.667 5.7878 1.14 Q V . 17.750 5.7956 1.14 Q V . 17.833 5.8015 0.84 Q V . 17.917 5.8073 0.84 Q V . 18.000 5.8131 0.84 Q V . END OF FLOODSCx ROUTING ANALYSIS F L 0 0 D R O U T I N G A N A L Y S I S ACCORDING TO RIVERSIDE COUNTY FLOOD CONTORL AND WATER CONSERVATION DISTRICT (RCFC&WCD) 1978 HYDROLOGY MANUAL (c) Copyright 1989-99 Advanced Engineering Software (aes) Ver. 7.0 Release Date: 01/01/99 License ID 1269 Analysis prepared by: MDS CONSULTING Planners * Engineers * Surveyors 17320 Redhill Avenue, Suite 350 Irvine, CA 92614 ************************** DESCRIPTION OF STUDY ************************** * TENTATIVE TRACT NO. 30043 * Q100 / 24 HOURS STORM * GC2 AREA ************************************************************************** FILE NAME: C:\AES99\HYDROSFT\FLOODX\30043\GC2UH.100 TIME/DATE OF STUDY: 10:55 01/17/2001 **************************************************************************** FLOW PROCESS FROM NODE 10.00 TO NODE 20.00 IS CODE = 1 ------_--_--____-------------------------------------------------------------------- »»>SUBAREA RUNOFF (UNIT-HYDROGRAPH ANALYSIS) ««< (UNIT-HYDROGRAPH ADDED TO STREAM #1) WATERCOURSE LENGTH = 1560.000 FEET LENGTH FROM CONCENTRATION POINT TO CENTROID = 1075.000 FEET ELEVATION VARIATION ALONG WATERCOURSE = 10.000 FEET BASIN FACTOR = 0.015 WATERSHED AREA = 17.000 ACRES BASEFLOW = 0.000 CFS/SQUARE-MILE WATERCOURSE "LAG" TIME = 0.063 HOURS CAUTION: LAG TIME IS LESS THAN 0.50 HOURS. THE 5 -MINUTE PERIOD UH MODEL (USED IN THIS COMPUTER PROGRAM) MAY BE TOO LARGE FOR PEAK FLOW ESTIMATES. DESERT S -GRAPH SELECTED UNIFORM MEAN SOIL-LOSS(INCH/HOUR) = 0.065 LOW SOIL -LOSS RATE PERCENT(DECIMAL) = 0.850 MINIMUM SOIL -LOSS RATE(INCH/HOUR) = 0.032 USER -ENTERED RAINFALL = 5.00 INCHES RCFC&WCD 24 -Hour Storm (15 -Minute period) SELECTED RCFC&WCD DEPTH -AREA ADJUSTMENT FACTOR(PLATE E-5.8) = 1.0000 UNIT HYDROGRAPH TIME UNIT = 15.000 MINUTES UNIT INTERVAL PERCENTAGE OF LAG -TIME = 394.570 RUNOFF HYDROGRAPH LISTING LIMITS: MODEL TIME(HOURS) FOR BEGINNING OF RESULTS = 10.00 MODEL TIME(HOURS) FOR END OF RESULTS = 18.00 ---------------------------------------------------------- ---------------------------------------------------------- UNIT HYDROGRAPH DETERMINATION ---------------------------------------------------------------------------- INTERVAL "S" GRAPH UNIT HYDROGRAPH NUMBER MEAN VALUES ORDINATES(CFS) ---------------------------------------------------------------------------- 1 64.580 44.258 2 97.840 22.793 3 99.964 1.456 4 99.986 0.015 5 99.996 0.007 6 100.000 0.002 TOTAL STORM RAINFALL(INCHES) = 5.00 TOTAL SOIL-LOSS(INCHES) = 1.41 TOTAL EFFECTIVE RAINFALL(INCHES) = 3.59 ---------------------------------------------------------------------------- TOTAL SOIL -LOSS VOLUME(ACRE-FEET) = 1.9938 TOTAL STORM RUNOFF VOLUME(ACRE-FEET) = 5.0867 --------------------------------------------------------------------------- L 2 4- H O U R S T 0 R M R U N O F F H Y D R 0 G R A P H HYDROGRAPH IN FIVE-MINUTE UNIT INTERVALS(CFS) (Note: Time indicated is at END of Each Unit Intervals) ---------------------------------------------------------------------------- TIME(HRS) VOLUME(AF) Q(CFS) 0, 5.0 10.0 15.0 20.0 10.083 1.3879 4.81 QV 10.167 1.4211 4.81 Q V 10.250 1.4542 4.81 Q V 10.333 1.4820 4.04 Q .V , 10.417 1.5098 4.04 Q .V 10.500 1.5376 4.04 Q . V 10.583 1.5728 5.11 Q V 10.667 1.6080 5.11 Q V 10.750 1.6432 5.11 Q V 10.833 1.6824 5.70 Q V 10.917 1.7216 5.70 Q V 11.000 1.7609 5.70 .Q V 11.083 1.7989 5.53 Q V 11.167 1.8370 5.53 Q V 11.250 1.8751 5.53 .Q V 11.333 1.9125 5.43 Q V 11.417 1.9498 5.43 Q V 11.500 1.9872 5.43 Q V 11.583 2.0216 5.00 Q. V 11.667 2.0561 5.00 Q. V 11.750 2.0905 5.00 Q. V 11.833 2.1249 5.01 Q V 11.917 2.1594 5.01 Q V 12.000 2.1939 5.01 Q V 12.083 2.2398 6.67 Q V 12.167 2.2857 6.67 Q V 12.250 2.3317 6.67 Q V . 12.333 2.3848 7.71 Q V , 12.417 2.4379 7.71 Q V. 12.500 2.4910 7.71 Q V. 12.583 2.5484 8.33 Q V 12.667 2.6058 8.33 Q V 12.750 2.6632 8.33 Q V 12.833 2.7238 8.81 Q ,V 12.917 2.7845 8.81 Q V 13.000 2.8451 8.81 Q . V 13.083 2.9144 10.06 Q V 13.167 2.9836 10.06 Q V 13.250 3.0529 10.06 Q V C 13.333 3.1262 10.65 .Q V 13.417 3.1996 10.65 .Q V 13.500 3.2729 10.65 .Q V 13.583 3.3298 8.27 Q V 13.667 3.3867 8.27 Q V 13.750 3.4437 8.27 Q V d 13.833 3.4921 7.03 Q V , 13.917 3.5405 7.03 Q V 14.000 3.5888 7.03 Q V . 14.083 3.6429 7.85 Q V . 14.167 3.6969 7.85 Q V. ( 14.250 3.7510 7.85 Q V. 14.333 3.8067 8.09 Q V. 14.417 3.8624 8.09 Q V 14.500 3.9182 8.09 Q V 14.583 3.9734 8.02 Q V , 14.667 4.0287 8.02 Q V 14.750 4.0840 8.02 Q V € 14.833 4.1377 7.81 Q V 14.917 4.1915 7.81 Q V 15.000 4.2453 7.81 Q V 15.083 4.2968 7.49 Q V 15.167 4.3484 7.49 Q V 15.250 4.4000 7.49 Q V 15.333 4.4492 7.16 Q V 15.417 4.4985 7.16 Q V 4 15.500 4.5478 7.16 Q V 15.583 4.5903 6.16 Q V 15.667 4.6327 6.16 Q V 15.750 4.6752 5.16 Q V ( 15.833 4.7145 5.71 .Q V 15.917 4.7539 5.71 Q V 16.000 4.7932 5.71 ,Q V 16.083 4.8096 2.38 Q V t 16.167 4.8260 2.38 Q V { 16.250 4.8423 2.38 Q V , 16.333 4.8470 0.68 .Q V , 16.417 4.8517 0.68 .Q V . l 16.500 4.8564 0.68 Q V . 16.583 4.8589 0,36 Q V . 16.667 4.8614 0.36 Q V . 16.750 4.8639 0.36 Q V . 16.833 4.8656 0.26 Q V . 16.917 4.8674 0.26 Q V . 17.000 4.8692 0.26 Q V . 17.083 4.8741 0,70 .Q V .. ( 17.167 4.8789 0.70 Q V . 17.250 4.8838 0.70 .Q V . 17.333 4.8903 0.94 .Q V , s 17.417 4.8968 0,94 .Q V . 17.500 4.9033 0,94 Q . . V . 17.583 4.9100 0.97 Q V . 17.667 4.9166 0.97 Q V . 17.750 4.9233 0.97 Q . V . 17.833 4.9285 0.76 Q V . 17.917 4.9338 0.76 Q . V . 18.000 4.9390 0.76 Q . . . V END OF FLOODSCx ROUTING ANALYSIS e 0 100 200 400 800 C:AUE TAMPW 11 11 44 LE" TRIBUTARY AREA RETENTION BASIN, LAKE PREPARED FOR: DEVELOPMENT CORPORATION 55-920 PGA Boulevard (760) 564-8000 La Quinta, CA 92253 FAX (760) 564-8005 PREPARED BY: WT HYDROGRAPH ANALYSIS TENTATIVE TRACT No. 30043 WY OF LA Qu11lTA I:/51328/HYDROIUNITL HYD 01/17/2001 7947 dJ Ari! W 59 . o�m u vxxss oolicx v:,Q:7ao-niwis 1 s i w V i r z raz- 7eo-m-u7s FLANNIRS INGINIRRS SYRVI70Rf WT HYDROGRAPH ANALYSIS TENTATIVE TRACT No. 30043 WY OF LA Qu11lTA I:/51328/HYDROIUNITL HYD 01/17/2001