Loading...
SP 1997-029 The Centre at LQ (1997) Superseded1 1 1 1 1 1 1 THE CENTRE AT LA QUINTA SPECIFIC PLAN PREPARED FOR STAMKO DEVELOPMENT CO. AND THE CITY OF LA QUINTA MAINIERO, SMITH AND ASSOCIATES, INC. IN CONJUNCTION WITH WALKER/RANCOURT + ASSOCIATES HORTON SHEPARDSON ASSOCIATES June 12, 1997 C r r u THE CENTRE AT LA QUINTA Table of Contents Section I. Summary 1.10 Purpose ................................................ p.1 1.20 Executive Summary ...................................... p. 2 1.20.1 The Land ............. ,...................... p.2 1.20.2 The Project .................................. p. 4 1.20.3 The Process .................................. p. 8 1.20.3.1 Relationship to General Plan ............... p. 8 1.20.3.2 Relationship to Zoning and Development ...... p. 8 1.20.3.3 Relationship to Other Agencies ............. p. 11 Section II. Specific Plan 2.10 Project Description ...................................... p. 12 2.10.1 The Site .................................... p. 12 2.10.2 Site Plan ................................... p. 12 2.10.3 Landscape Plan .............................. p. 12 2.10.4 Utilities ..................................... p. 12 2.10.5 Art in Public Places ........................... p. 13 2.20 Phasing ............................... ..............p.14 2.20.1 Phasing Description ........ ................... p. 14 2.20.2 Infrastructure Phasing . . . ................ • ... - . p. 14 2.20.3 Grading ............. . . .................... p. 15 2.20.3.1 Grading Plan ........................... p. 15 2.20.3.2 Erosion Control ......................... p. 15 2.20.3.3 SWPPP/NPDES .................... I ... p. 15 2.30 Drainage/Flood Control ................................... p. 18 2.30.1 Hydrology ..................... ........ .-...... P. 18 2.30.2 Flood Control Master Plan ..................... P. 18 2.30.3 On-site Storm Water Retention .................. p. 18 2.30.3 Nuisance Water .............................. P. 19 2.40 Utilities ................................................ p. 20 2.40.1 Sewer Plan ................................. p. 20 2.40.2 Water Plan .......................... . ....... p. 20 2.40.2.1 Well Site .............................. p. 20 2.40.3 Electrical Plan ................... . ........... p. 20 2.40.4 Other Utilities ... . ............... . ............ p. 21 t 1 11 2.50 Land Use ............................................. p.27 2.50.1 Land Use Plan ............................... p. 27 2.50.1.1 Auto Mall ............. . ............... p. 27 2.50.1.2 Mixed Regional Commercial Development .... p. 29 2.50.2 Development Standards ....................... p. 31 2.50.2.1 Permitted/Conditional Uses ................ p. 31 2.50.3 Design Guidelines ............................ p. 32 2.50.3.1 General Architectural Theme ............... p. 32 2.50.3.2 Acceptable Building Materials .............. p. 32 2.50.3.3 Colors ................................ p. 32 2.50.3.4 Roofs ................................. p. 32 2.50.3.5 Equipment Screening .................... p. 32 2.50.3.6 Fencing and Walls ...................... p. 33 2.50.3.7 Site Lighting ........................... p. 33 2.50.4 Project Operations ............................ p. 34 2.50.4.1 Project Operations -Auto Mall .............. p. 34 2.50.4.1.1 Site Plan .............................. p. 34 2.50.4.1.2 Lighting ............................... p. 35 2.50.4.1.3 Noise ................................. p. 35 2.50.4.1.4 Special Events ......................... p. 35 2.60 Circulation ............................................ p.37 2.60.1 Overview ................................... p. 37 2.60.2 Off-site Circulation Plan ........................ p. 37 2.60.3 Public Transportation/Transportation Demand Mgmt. . p. 37 2.60.4 On-site Circulation Plan ........................ p. 39 2.60.4.1 La Quinta Centre Drive ................... p. 39 2.60.4.2 Auto Centre Drive/Auto Centre Way ......... p. 39 2.60.4.3 Mixed Regional Commerical Center Circulation p. 39 2.70 Landscape ............................................. p.41 2.70.1 Landscape Concept ........................... p. 41 2.70.2 Landscape Development Standards .............. p. 41 2.70.3 Landscape Palette ............................ p.42 2.70.4 Landscape Maintenance ....................... p.43 2.80 Signage ................. ............. p.44 2.80.1 Signage Concept ............................. p. 44 2.80.1.1 Signage Concept -Auto Mall ..................... p. 44 2.80.1.2 Signage Concept -Mixed Regional Commercial Center p. 45 Section III Appendices Appendix A- Conditions of Approval Appendix B - General Plan Policies I Section IV Environmental Impact Report J 1 TABLE OF EXHIBITS The Centre at La Quinta r Exhibit 1 Aerial Photo .......................................... . . . p. 3 Exhibit 2 Overall Site Plan ........................................ . p. 5 Exhibit 2-1 Phase I & II Site Plan ..................................... p. 6 Exhibit 2-2 Phase III Site Plan ........................................ p. 7 Exhibit 3 City General Plan ......................................... P. 9 Exhibit 4 City Zoning ........................................... . P. 10 Exhibit 5 Exhibit 6 Grading/Drainage Plan ................................... Utilities- Sewer ......................................... p. 16 p. 22 Exhibit 7 Utilities - Telephone ..................................... p. 23 Exhibit 8 Utilities - Natural Gas .................................... p• 24 Exhibit 9 Utilities - Electrical p• 25 Exhibit 10 Utilities - Water ......................................... p. 26 Exhibit 11 Street Cross Sections p. 38 Exhibit 12 Landscape Palette ::.................................. p. 42 Exhibit 13 Landscape - Highway 111 Cross Section ..................... p. 46 Exhibit 14 Landscape - Highway 111 Concept Plan ..................... p. 47 Exhibit 15 Landscape - Adams Road ................................. p. 48 Exhibit 16 Landscape - Auto Centre Drive ............................. p. 49 Exhibit 17 Signage - Plan .......................................... p. 50 Exhibit 18 Signage - Monument Signs ................................ p. 51 Exhibit 19 Signage - Building ....................................... p. 52 r i SPECIFIC PLAN THE CENTRE AT LA QUINTA 1.10 PURPOSE The purpose of this Specific Plan is to set forth the detailed development principles, guidelines, and programs to facilitate the development of an 87 acre site located on the south side of Highway 111 between Adams Street and Dune Palms Road. The project is called The Centre at La Quinta. The Specific Plan shall include a statement of the relationship of the specific plan to the General Plan. The establishment of specific performance, design, and development standards is set forth to guide the development of the subject property in such a way as to implement the General Plan while maintaining some flexibility to respond to changing conditions which may be a factor in any long term development program. The document also acts to augment the City's Zoning Ordinance by providing particular design guidelines, a tailored list of allowable, conditionally allowable, and prohibited uses for the site, and unique development standards. This Specific Plan is intended to meet the requirements for a Specific Plan as set forth in State law. The State authorizes cities and counties to adopt Specific Plans as appropriate in implementing their General Plans. Such a plan is to include the detailed regulations, conditions, programs, and any proposed legislation that is necessary for the systematic implementation of the General Plan. The Specific Plan provides the linkage between the General Plan (and the general goals and policies of the City) and the detailed implementation of that plan with tools such as zoning ordinances, subdivision ordinances, and the like. The Government Code (Section 65451) sets forth the minimum requirements of a Specific Plan and states: 1 "A Specific Plan shall include a text and diagram or diagrams which specify all of the following in detail: 1). The distribution, location, and extent of the uses of land, including open space, within the area covered by the plan. 2). The proposed distribution, location and extent and intensity of major components of public and private transportation, sewage, water, drainage, solid waste disposal, energy, and other essential facilities proposed to be located within the area covered by the plan and needed to support the land uses described by the plan. 3). Standards and criteria by which development will proceed, and standards for the conservation, development, and utilization of natural resources, applicable. where 4). A program of implementation measures including regulations, programs, public works projects, and financing measures necessary to carry out paragraphs (1), (2), and (3)." The Specific Plan shall include a statement of the relationship of the specific plan to the General Plan. The establishment of specific performance, design, and development standards is set forth to guide the development of the subject property in such a way as to implement the General Plan while maintaining some flexibility to respond to changing conditions which may be a factor in any long term development program. The document also acts to augment the City's Zoning Ordinance by providing particular design guidelines, a tailored list of allowable, conditionally allowable, and prohibited uses for the site, and unique development standards. SPECIFIC ALGIN THE CENTRE AT LA QUINTA 1 1.20 EXECUTIVE SUMMARY 1.20.1 THE LAND The Centre at La Quinta is a proposed mixed commercial development on 87 acres of property located at the southeast corner of Highway 111 and Adams Street in the City of La Quinta. The property is delineated by the City's General Plan as Commercial Park and Mixed/Regional Commercial and is zoned Regional Commercial (CR). This zoning type allows a wide range of commercial activities as outlined in the attached excerpt from the City's recently adopted Zoning Ordinance (Appendix B). The site is vacant and exhibits characteristics of the stabilized sand dune formations found in this part of the Coachella Valley. The site is generally flat (portions had been previously cultivated) but has some dune formations with an elevational difference of up to 25 feet. The site has nearly 2300 feet of frontage on Highway 111 and also abuts Adams Street on the west side of the project. Property to the south is vacant and is zoned for residential uses. Property to the east is an underdeveloped commercial site with a single home and a small date grove. Dune Palms Road lies approximately 300 feet to the east of the site. Property to the north, across Highway 111 is vacant. Property directly west is partly vacant and zoned for commercial uses and partly developed residential property (Lake La Quinta). The site is shown on an aerial photograph in Exhibit 1. Commercial use of the subject site was analyzed in the City's General Plan EIR which was approved in 1992. The Environmental Conservation Element of the General Plan identified the subject property as being potential habitat to the ' Coachella Valley Fringed Toed Lizard and within the approved Habitat Fee area. EXHIBIT 1 AERIAL PHOTOGRAPH SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Engheering Walker/Rancourt + Assoc. Architecture Horton/SheWdson Assoc. Lendsc" Architecture fA ' THE CENTRE! AT LA WNTA s��cr�rc �r�anr 1 1.20.2 THE PROTECT The Centre at La Quinta is a multi -phased commercial proposal designed around two main activities: an auto sales mall and a large scale retail complex. Exhibit 2 depicts the proposed development. The first phase of development will occur on the northwest portion of the property (Highway 111 and Adams Street) and will ' contain an integrated auto sales facility for up to 5 dealerships . Included in the first phase will be all on-site streets including La Quinta Centre Drive and Auto Centre Drive/Auto Centre Way, landscaping, lighting, and infrastructure as well as perimeter improvements such as walls and signage. Included in Phase I will be the mass grading of the entire westerly half of the project including La Quinta Centre Drive. Phase II will build out the remaining dealers and possibly auto related commercial. Off-site improvements included with Phase I include the entire frontage of Adams Street (curb/gutter, landscaped median, landscaped parkway and infrastructure extensions), the westerly frontage portion of Highway 111 (curb/gutter, 1 landscaped parkway and necessary infrastructure extensions). The development of Phase II and/or Phase III will initiate the implementation of the remainder of the Highway 111 improvements including the landscaped median. The main site access will be a signalized, landscaped entry from Highway 111 and will be shared with the Phase III commercial portion of the project. A second entry will be provided on the west boundary from Adams Street. The entry will align with Avenue 47 and could be signalized if warrants are met. The auto mall will include coordinated landscape, lighting, signage, and maintenance. A property owners association comprised of the property owners in Phases I and II will handle all landscape and common area maintenance associated with the auto mall portion of the project. All activity will be contained on-site including vehicle unloading. Phase III will focus on the eastern portion of the site and is focused on the development of a multi-user retail center 400,000 s.f. of retail floor area. Probable candidate uses include restaurants, entertainment, big box retail, financial, and offices. The allowable, conditionally allowable, and prohibited uses shall be generally as set forth in the zoning regulations for the CR zone with some exceptions as noted in section 2.50.2.1. Phase III common area improvements will be maintained by a separate property owners association. The site development concept for Phase III is still in the development stage and will be changed but not in a way that increases the density and/or intensity of the site development and/or the maximum heights of the proposed buildings. RELOCATE EXISTING SIGNAL 6' MASONRY WALL Hl%"A �1111VA Y -7— Jif_ 1ii11:'r3 i I 41H I R'll I ll-fl4d 1% mum :S mWeAl J�ljc!10-!10 U-77-1 '- - - 'j7rj Wl 7 ' Q - -- — � _�= - - :.I- 1 Vuji ,,n p u; l iurn p m FFe eENi:RE JI15ullill'' [I I v II i I Li HIK W, d ql 14 1 rA 01 T I I mull. - Tl CSD FRI- Rl _H1 t -h 3, Ti T �i T WELL SITE e, MASONRY WALL FUTURE SIGNAL PER OrrY FIEOUIREMENT FOR ULTIMATE R.O.W. 15' DEDICATION (70' HALF—STREET) W AVERAGE LANDSCAPE PARKWAY /--RIGHT IN/RIGHT OUT ACCESS EXHIBIT 2 1 SITE PLAN SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Pl"ng/ErghwhV Walker/Ramourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Archfiecture RELOCATE EXISTING SIGNAL. 6' MASONRY WALL —. H&H—WAY 6' MASONRY WALL Phase land EXHIBIT 2-1 SITE PLAN PHASE I AND II SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. P1srr kWEngiieerhV Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture a Site Area Bks Area Max S�Ht SRe 1 4.03 Acres 40,000 61. 35 Ft. Site 2 3.10 Acres 22,000 Sf. 35 Ft Site 3 4.04 Acres 27,600 Sf. 35 Ft. Site 4 427 Acres 30,000 Sf. 35 Ft Site 5 5.02 Acres 31,600 Sf. 35 Ft Site 6 3.07 Acres 28,000 St. 35 Ft. 5iie 7 3.82 Acrea 32,600 Si. 56 Ft Si►e 8 3.93 Acres 32,600 Sf. 35 Ft Site 9 4.21 Acres 30,000 Sf. 35 Ft 275,000 V. EXHIBIT 2-1 SITE PLAN PHASE I AND II SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. P1srr kWEngiieerhV Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture a oil ifflia '4 I liki, 1 ■ INI r� I.111 HIGHER Jill PER CITY REWIF EMENT FOR ULTIMATE RO.W. f ---, -002 I ■ -0 1' ■IInIIIIIIIIIIIII Phase .. . ■ m r, ..m; j Wl* g 1 8,000 8f. 1 25 Buking 2 8,000 Sf. 1 25 Bum 3 8,000 St. 1 25 &ikir►g 4 8,0&0 Si. 1 W BukkQ 5 130,000 8f. 2 40' Binding 6 78,000 Sf. 2 40' Bukkg 7 100,000 8f. 1 40' Buiding 8 60,000 Sf. 1 40' 400,000 Sf. EXHIBIT 2-2 SITE PLAN PHASE III SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Mannkg/Engheering Walker/Rsncourt + Assoc. Archdacture Horton/SheWdson Assoc. Landscape Architecture 7 sPscrFrc PLAN THE gENTRs A T La urrvra 1.20.3 THE PROCESS 1.20.3.1 RELATIONSHIP TO THE GENERAL PLAN Implementation of development within the Centre at La Quinta Specific Plan area is intended to carry out the goals and policies contained in the General Plan of the City of La Quinta in a planned and orderly fashion. All development within the Centre at La Quinta Specific Plan shall be consistent with the provisions of the La Quinta General Plan. The General Plan Land Use for the site is shown in Exhibit 3. 1 1.20.3.2 RELATIONSHIP TO ZONING AND DEVELOPMENT PROCESSES The property is already properly planned and zoned for the uses projected for the site. Exhibit 4 depicts the zoning on and surrounding the site. The City of La Quinta requires a Specific Plan to establish an overall master development plan in the circumstance of the CR zoning classification. In addition to the Specific Among the important provisions of the General Plan which will be implemented upon the development of The Centre at La Quinta include: • Land Use -The General Plan delineates the Highway 111 corridor as a Mixed/Regional Commercial (M/RC) land use. The proposed project is consistent with the approved land use. The Specific Plan sets forth the maximum Floor Area Ratio (F.A.R) for the project at .18, well under the maximum F.A.R. for M/RC uses (.35). • Circulation -The Circulation Element of the General Plan outlines the design and location of required street improvements to complete the transportation ' system in the City. The Centre at La Quinta will complete portions of two important links in the City's circulation network: Highway 111 and Adams ' Street. Included in the improvements will be sidewalks, bicycle links, bus stops, and signal improvements. • Roadway Image Corridors -In addition to roadway improvements, the project will implement special roadway corridor improvements which will evoke the unique identity and character sought by the City of La Quinta. • Water Quantity and Quality -The Specific Plan outlines the use of drought tolerant planting and irrigation techniques and incorporates a grading concept designed to retain stormwater on site to assist in recharge of groundwater supplies. • Infrastructure -The Specific Plan incorporates plans to complete the infrastructure which lies adjacent to the project site. 1 1.20.3.2 RELATIONSHIP TO ZONING AND DEVELOPMENT PROCESSES The property is already properly planned and zoned for the uses projected for the site. Exhibit 4 depicts the zoning on and surrounding the site. The City of La Quinta requires a Specific Plan to establish an overall master development plan in the circumstance of the CR zoning classification. In addition to the Specific ^� _ � GEM 074qkHE DESERT .:, GENERAL PLAN F , L� j_� - -' ,/' PROPOSED ', `� ' r - `� LAND USE POLICY DIAGRAM RESIDENTIAL LAND USES _ VLDR VERY LOW DENSITY RESIDENTIAL (0-2 oU/AC) i }1 �- .L� tx - _ 10 LDR LOW DENSITY RESIDENTIAL (2-4 Du/AC) :.. MDR MEDIUM DENSITY RESIDENTIAL (4-9 MAC) MEDIUM HIGH DENSrrY RESIDENTIAL (e-12 MAC) t, k'" z (i,- F' HIGH DENSrTY RESIDENTIAL (12-:6 DU/AC) SITE " t'' o ® RURAL RESIDENTIAL OVERLAY L; ;`•� !� 0 �COMMERCIAL LAND USES MIXED/REGIONAL COMMERCIAL r �/ e _ - �'Ej - COMMUNITY COMMERCIAL NEIGHBORHOOD COMMERCIAL h` MARC°I COMMERCIAL PARK OFFICE _ {�_` '�y~`ti TC§: TOURIST COMMERCIAL r �-, � Q f � j i� ¢� %VC VILLAGE COMMERCIAL ®NON-RESIDENTIAL OVERLAY L= OTHER LAND USES [' T I j l F` ®URBAN MIX I' y MAJOR COMMUNITY FACILrTIES fi PARK FACILITIES OPEN SPACE _.. _GOLF COURSE OPEN SPACE Lp js M ''�+'ra WATERCOURSE/FLOOD CONTROL `w_as 'RE IU .s., � �?� a 1� r�._�.m.- ♦ I 6 OCTOBER 1..o 92 z 0 A AVEI IU'`_ 50 EXHIBIT 3 CIN GENERAL PLAN SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. PianNng/Eng'neering Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture E l THE DESERT f.RI..d.I1G.�.1L1OV ® VERY LOW DENSITY RESIDENTIAL RL LOW DENSfTY RESIDnmhL �] COVE RESIDENTIq- F-R-M-1 MEDIUM DENSITY RES DMAL ®� MEDIUM H10H DENSrTY RmDENT1aL F:�QT.�. HIGH DENSITY RESIDEN LOL TIE MH �frl �ti • f FWP-j WJAGE PARK VILLAGE SOUTH THE DESERT f.RI..d.I1G.�.1L1OV ® VERY LOW DENSITY RESIDENTIAL RL LOW DENSfTY RESIDnmhL �] COVE RESIDENTIq- F-R-M-1 MEDIUM DENSITY RES DMAL ®� MEDIUM H10H DENSrTY RmDENT1aL F:�QT.�. HIGH DENSITY RESIDEN LOL TIE MH DF EASMICT FV—C-1 VVIAG£ CORE FWP-j WJAGE PARK VILLAGE SOUTH I VILLAGE NORTH TAMPICO URBAN MIX YR -10 000 VILLAGE RESIDE?nM NQNRESlDr►:TIA+ DiMIQTTS FC—R-1 REGIONAL COMMERCIAL CR COMMERCIAL PARK CC COMMUNrrf COMMERCIAL CN NEIGHBORHOOD COMMERCIAL ® rDURIST CCWMERCIAL MM OFFICE COMMERCIAL MC 1 WVOR CDVWUNETY FACILITIES ,SPECIAL ® PURPOSE pSTRJICT5 FARKS AND P.ECRFAMON GOLF COURSE ® OPEN SPACE ® fLDODPLAIN OVERLAY ® DISTRICTS RESIDENnAl SPECIFIC PLM 01-73LAY EED NONRESIDENTIAL OVERLAY EEg RURAL RESID-2C AL MRLAY Goma HILLSIDE CONSEtVAT04 OVERLAY MUALLY OREENTED GUSNM C+Tr_RLAY 0 EWE R:kN O ERI.AY EXHIBIT 4 -I CITY ZONING SPECIFIC PLAN THE CENTRE AT LA QUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/6Vkx Bring Walker/Rancourt + Assoc. Ardtitecture Horton/SheWdson Assoc. Landscape Arctitecture 10 SPECIFIC PLAN THE CENTRE AT LA QUINTA Plan, the processing for entitlements proposes the inclusion of a Development ' Agreement, a Tract or Parcel Map, and a Conditional Use Permit for the automobile dealerships. Individual applications will be under normal City requirements at the time of the application for Site Development Permits (architecture, landscape architecture, signage, final grading, etc.). Those uses which may require Conditional Use Permits as set forth in the Zoning Ordinance of the City of La Quinta, shall submit such an application unless otherwise specified within this Specific Plan. Such conditional uses could include mixed use commercial and residential, wholesaling, vocational schools, bars and taverns, and health clubs among others. 1.20.3.3 R ELATIONS H I ID TO OTHER AGENCIES In addition to City approvals, permits will be required by Caltrans for the work along Highway 111, and by the Coachella Valley Water District (CVWD) for moderate extensions to water and sewer lines. Other infrastructure extensions will be required by the Imperial Irrigation District for electrical power, General Telephone Company (GTE) for telephone service and Colony Cablevision for cable TV service. 1 1 I L SPECIFIC PLAN _ THE CENTRE AT LA QUIN' A 2.10 PROJECT DESCRIPTION 2.10.1 THE SITE The landscape concept follows a "desert oasis" theme emphasizing water efficient materials exhibiting color and form with a deemphasis on the use of turf areas. Parking areas in the mixed regional center will feature the concept of a high canopy tree form to reduce the conflict between landscape elements and project graphics. The auto mall will use tree forms sparingly and concentrate landscape form and color along the street frontage of each site. Turf areas will ' be integrated into the landscape in front of each dealership. Most landscape areas throughout the project will be used for storm water retention. 2.10.4 UTILITIES Utility extensions will be moderate with most utilities existing at the perimeter of the site. Some upgrades will be required by the individual utility companies providing service to the property. (Exhibits 6 to 10 depict the utility improvements planned in conjunction with the project). A well site will be provided to the CVWD at the southwest corner of the property, fronting on Adams Street. Street widening implementing the General Plan will be installed ' concurrently with Phase I and Phase II or Phase. III. The timing of Highway 111 1 12 The site is an 87 acre parcel located on the southeast corner of Highway 111 and Adams Street in the City of La Quinta. The site is currently vacant although the northern half of the property served at one time in an agriculture production capacity. The Centre at La Quinta is a multiple use regional commercial project designed around two main uses. The westerly half of the 87 acre site will be devoted to automobile sales and auto related commercial in an integrated auto mall; the easterly portion is expected to be developed as a mixed regional commercial center with a series of freestanding and attached buildings comprising 400,000 square feet of floor space. 2.10.2 SITE PLAN The site Ian will feature required, extensive, coordinated landscape buffers to p both Highway 111 and Adams Street which will implement the City's Highway 111 streetscape planning efforts (ongoing during the project's planning phase); significant building setbacks to both adjacent public streets; controlled, signalized vehicular access from both streets (upon warrants); and integrated architecture, landscape architecture and signage concepts established through the Specific Plan and controlled through private CC&Rs as well as City processes. 2.10.3 LANDSCAPE PLAN The landscape concept follows a "desert oasis" theme emphasizing water efficient materials exhibiting color and form with a deemphasis on the use of turf areas. Parking areas in the mixed regional center will feature the concept of a high canopy tree form to reduce the conflict between landscape elements and project graphics. The auto mall will use tree forms sparingly and concentrate landscape form and color along the street frontage of each site. Turf areas will ' be integrated into the landscape in front of each dealership. Most landscape areas throughout the project will be used for storm water retention. 2.10.4 UTILITIES Utility extensions will be moderate with most utilities existing at the perimeter of the site. Some upgrades will be required by the individual utility companies providing service to the property. (Exhibits 6 to 10 depict the utility improvements planned in conjunction with the project). A well site will be provided to the CVWD at the southwest corner of the property, fronting on Adams Street. Street widening implementing the General Plan will be installed ' concurrently with Phase I and Phase II or Phase. III. The timing of Highway 111 1 12 fl SPECIFIC PLAN THE CENTRE AT LA 9UINTA improvements will be at the discretion of Caltrans working with the City Public Works Department. 2.10.5 ART IN PUBLIC PLACES The requirement for Art in Public Places will be fulfilled in an integrated fashion with the concept embedded in the overall plan from the onset. The prime 1 location for such an installation is expected to be the generous landscape setback along Highway 111. The average distance from the curb to the project in this area will be 62 feet which will include a sidewalk/bikepath and possibly a bus stop. Due to the probable differential in timing between Phases I, II and III, and with the different scale and type of development between the west and east sides of the project, it may be appropriate to tailor the Art in Public Places concept individually for each half. 0 1 13 SPECIFIC Pt AN THE CENTRE AT LA QUINTA 2.20 PHASING 2.20.1 PHASING DESCRIPTION As currently scheduled, the project will be phased with Phases I and II comprising the auto mail which can be expected to be completed in year 2000 and Phase III comprising the mixed regional commercial center which can be expected to be completed in year 2005. See Exhibit 2 for phasing. Phase I will comprise five parcels for auto dealerships with Phase II adding four parcels for additional dealerships and/or auto related commercial. No more than two of the parcels in Phase II may be developed with uses other than auto dealers. The uses expected to be developed if dealerships are not secured are outlined in Section 2.50.2.1. Phase III is the easterly half of the property and is planned to accommodate a mixed regional commercial center. Phase III is expected to begin in year 2000 and be completed in year 2005. The intensity and scope of Phase III will be less than the approved General Plan and existing zoning for the site. As such, the General Plan sets forth the development potential as a retail commercial development with a maximum floor area ratio (FAR) of up to .35. This would translate to a development up to 580,000 square feet. This Specific Plan sets E the development intensity of Phase III at 400,000 square feet of floor area. Phase III will be broken down into four additional subphases. 1 14 For purposes of this Specific Plan, the FAR will be calculated on the basis of the gross site area. This shall not be construed to allow a higher density than allowed by the General Plan. - 2.20.2 INFRASTRUCTURE PHASING~ The first phase of infrastructure development will coi tide with Phase I and will include the westerly frontage portion of Highway 111 (curb/gutter, landscaped parkway, and necessary infrastructure extensions) and the entire frontage of Adams Street (curb/gutter, landscaped median, landscaped parkway, and infrastructure extensions). La Quinta Centre Drive as well as Auto Centre Drive and Auto Centre Way, will be completed with the Phase I along with the on-site infrastructure located within the street right-of-way. Utilities will be extended to the site as necessary. The second phase of infrastructure will coincide with either the issuance of the first grading permit for Phase III, the issuance of the first building permit for Phase II, or the expiration of three (3) years following the recordation of the parcel map in connection with the project. The improvements will consist of the completion of Highway 111 improvements including the landscaped median along with utility extensions as necessary across the remainder of the project's 1 14 SPECIFIC PLAN THE CENTRE AT LA QUINTA I frontage. Exhibits 6 through 10 depict the location and scope of infrastructure ' improvements. 2.20.3 GRADING 1 2.20.3.1 GRADING PLAN The auto mall portion of the site (Phases I and II) and the internal road system will be mass graded as part of the initial site preparation. The rough pads will be established for the individual dealership and/or auto related commercial sites. It is estimated that the grading operation will move approximately 125,000 yards of dirt and there will be a net balance on the site. The mixed regional commercial center (Phase III), is also designed to be mass graded to establish rough pads for the various end users at the onset of the development of that phase. The grading for this phase is estimated to require a similar 125,000 yards and result in balanced grading for the project. Exhibit 5 depicts the rough grading and drainage concept for the property. 1 2.20.3.2 EROSION CONTROL The grading operations shall include adequate provisions for wind and water erosion control both during as well as after grading operations have ceased. This will include treatment of the Phase II sites which may remain undeveloped for several years. The details of erosion control shall be included in the project's Storm Water Pollution Prevention Plan (SWPPP) and PM 10 Plan. • Prewatering--The site shall be prewatered to a depth of three feet prior to the onset of grading operations. • During Grading --Once grading has commenced, and until grading has been completed, watering of the site and/or other treatment(s) determined to be appropriate shall be ongoing. • Post Grading --All disturbed areas shall be treated to prevent erosion for the term that the area will remain undeveloped. Wherever feasible, final - landscape and irrigation shall be installed. 1 2.20.3.3 SWPPP/NPDES/PM 10 Since the Coachella Valley experiences periods of moderate to heavy wind conditions, wind-blown dust and sand is a concern with mass grading operations, especially those in excess of five acres in size. Because of health concerns, the Environmental Protection Agency has instituted a plan in the valley to curb excess PM 10 (small particle dust). The City also participates in the National Pollutant Discharge Elimination System program. The grading concept for the 1 project will involve two phases of mass grading, each being approximately half of 1 15 TP (75.0) rel cyl r- SIGNAL_ 6 MASONRY WALL TP (64.5) PER ami CEG MEME 17 fit ---- r UL-fW FOR R.O.W. -- -1-: DEDICATiON 1 PAD PAD �.0 71.0 i S I 69.0 TP (62.5) I f iA TP -HP 1 ' TP -HP .7 . -AV-ESS TO �, ; ' - V -� �` �- 3`-�-_` ' TP ,,s�i'q '�,- _,.._ i 661.0 r-- 0 PAD 69.0 PAD -� 65.0 :y. �O w SETBACK ..... . t 6' iASo Y WIX PAC it 63.0 L Q TP (56.5) L -j 6' MASC�FFY WAL_L.. 193225 W AVE. LAM=A,PE PARKWAY RK3aT IN/RK31HT EXHIBIT 5 GRADING/ DRAINAGE PLAN SPECIFIC PLAN THE CENTRE AT LA QUINTA DRAINAGE CONCEPT: 10 MAJORITY OF ONSITE FLOWS DRAWN TO LANDSCAPE EASEMENTS ON PERIMETER OF LOTS. (9) HIGHWAY 1tl AND ADAMS STREET DRAIN TO LANE)SCAPE EASEMENTS ALONG RIGHT OF WAY. 30 SMALL OUANTMES OF STORM WATER OVERFLOWS TO SMALL COMMON RETENTION AREA AT SOUTH END OF LA QUINTA CENTRE DRIVE. STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Engineering Walker/Rancourt + Assoc. ArcMecture Horton/Shepardson Assoc. Landscape AreMecture 16 1 SPECIFIC PIAN THE CENTRE ATLA QUINTA r the 87 acre site or about 43.5 acres in size. The City of La Quinta requires SWPPP, NPDES and PM 10 plans to control the wind and water born erosion associated with such grading operations. The project will comply with the City's requirements relative to these programs. 1 L] ri 0 fl 1 17 SPECIFIC PLAN THE CENTRE AT LA QUINTA r 1 2.30 DRAINAGE/FLOOD CONTROL t 2.30.1 HYDROLOGY The Centre at La Quinta lies in a Zone C flood zone as determined by FEMA. Zone C includes areas that are not considered to be subject to flooding in a 500 year event. There are no tributary flows that have to be accommodated in the development of the site. On site flows must be managed including the City's requirement for on-site retention of all storm water from a 100 year storm. 1 2.30.2 FLOOD CONTROL MASTER PLAN ' The stormwater drainage system in the City of La Quinta is administered by the CVWD. Generally speaking, the system consists of improvements to the natural drainage channels that run through the City. There is no planned collection system to drain individual sites into these channels as there is a capacity limitation. The development of property must include provisions to insure that no additional storm water is conducted into these channels. No drainage fees are required by the City or CVWD. 1 2.30.3 _ ON-SITE STORM WATER RETENTION The City of La Quinta in conjunction with the CVWD requires each development to include provisions for the retention of all storm water attributed to the site. The design storm which creates the worst case scenario is a 100 year, 24 hour event. The Centre at La Quinta proposes to use the project's landscape areas for this retention. Each site within the auto mall will capture its storm water with retention being accomplished primarily in the landscape setback area along the internal, public streets. The total retention area will be approximately 7 acre-feet. The mixed regional commercial center in addition to retaining the storm waters attributed to it, will also retain the storm water attributed to the public, on-site street system. It will also use its landscape areas for this purpose. The mixed regional commercial center retention requirement will be approximately 8 acre- feet. ® Water falling on the perimeter public streets will be conveyed into the adjacent landscape setbacks for retention. The volume of this retention will be approximately .5 acre-feet. The overall grading and drainage plan is shown in Exhibit 5. 1 18 1 SPECIFIC P[.4N TFiE CENTRE AT LA QUINTA 1 2.30.3 NUISANCE WATER Nuisance water attributed to the project will be collected and directed to areas within the landscape. A series of dry wells will be installed to percolate this water. The amount of nuisance water is expected to be reduced due to the use of water efficient landscape and irrigation materials. 1 1 1 1 _ - 1 1 1 1 t19 fl SPECIFIC PLAN THE CENTRE AT 1A QUINTA 2.40 UTILITIES The Centre at La Quinta is well served by utilities and is situated in a corridor planned for a relatively intense scope of commercial development. No major utility extensions are anticipated in conjunction with the project. ' 2.40.1 SEWER PLAN Sanitary sewer facilities for La Quinta are provided by CVWD. The nearest sewer main is located on the west side of the site in Adams Street. The project will gravity flow to the main in Adams Street. No upsizing of facilities will be required. Exhibit 6 shows the schematic design for sewer facilities. 2.40.2 WATER PLAN Water facilities for La Quinta are provided by CVWD. A 12" main exists in Highway 111 and there is an 18" main in Adams Street. CVWD will require an 18" main that connects the Adams Street main to the Highway 111 main through the subject site. In addition, an 18" main will be constructed in Highway 111 from the main project entry to the easterly property line. Exhibit 10 shows the rschematic design for water service. 2.40.2.1 CVWD WELL SITE A 0.55 acre well site located at the southwest corner of the project is proposed to be dedicated to the CVWD. CVWD will develop the property. The location of the well site is shown on the Site Plan, Exhibit 2. 1 2.40.3 ELECTRICAL PLAN Electric facilities in La Quinta are provided by the Imperial Irrigation District. The nearest substation is located at Adams Street and the Whitewater River Channel. The District indicates that the design of the electrical service will depend on final load calculations for the overall project. The District will require the installation of underground facilities through the auto mall to join with future projects either to the east or to the south of the auto mall. The District will temporarily serve the project with an overhead connection to existing facilities on Adams Street. Exhibit 9 shows the schematic design for electrical facilities. 1 1 20 P SRECIFIC p[ �4N THE CENTRE AT LA QUtNTA 2.40.4 OTHER UTILITIES Natural gas is provided by the Southern California Gas Company. The nearest facility is a 6" line located in Highway 111 along the northerly frontage of the site. The conceptual plan for natural gas service is shown in Exhibit 8. Television cable service is provided by Continental Cable Vision with the nearest facilities located in Highway 111 abutting the site. Service will be extended to the site from this point of connection. Telephone service will be provided by GTE. Fiber-optic cable will be available at the corner of 48th Avenue and Adams Street. GTE expects to serve the project 1 from this location. Exhibit 7 shows the proposed connection for the telephone system. Waste disposal service is provided by Palm Desert Waste Management. Plans for incorporating recycling facilities shall be considered with each phase of development. Facilities shall be reviewed for compliance with all City ordinances by Community Development Staff upon submission of Site Development Plans. n 1 21 ' -: , �, RELOCATE EXtSTUNG 6M.A.SONRY WALL. t -- -- ref - - SK WAL fc�f-lwxy- ENENT PER CfTY FE-OUIFER FOR ULTUATE R.O.W. Dealer Dad I 6*1­4 1 Dealer pad 2 4,03 ACRES kCRES 3.10 ACRES 4.044 Dealer pad 3 --EXISTING 18" SEWER PLAZA gjkj�T Icy 1-1CC�ESS TO ADAMS STFEEET AL �tO (A I n I R;-_ Dealer Pad 5 5.02 ACRES o PROPOSED 8" SEWER SE �CRAC2"' 6' MASOWY WALL 10" Dealer pad 4 4.27 ACRES rllv C'ealleir Pad 00 421 ACRES Deafer pad 6 1,07 4 CRIES T -8"s PROPOSED 11" SEWER 4.) 1 00 '0 7 r"wer pad/Auto Ctr4T,-_,ci5j 8 J 1 1 3 Dpmk�r pad/AltoPNsted CorwvwcW 82 ACRES 3,W ACRES cvwr) WELL 1932 25 - 6' MASONRY WAU_ PROPOSED 8" SEWER \x W AV -E ILMOSCAPE PARKWAY RIGM INIFOU-IT T AC'r�'- - . EXHIBIT 6 UTILITIES SEWER SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Engineering Walker/Rancourt + Assoc. Architecture Horion/Shepardson Assoc. Landscape Architecture 22 J ,.'-6'MASONRY WALL. Hl(jPWAY FUUPC SIAL T Dealer pad I Dealer pad 2 A A ^Mt -- Dealer pad 3.10 ACRES I 3 PROPOSED TELEPHONE 4.04 ACRES PLAZA rlCfEss TO ADAMS STFEET a Dealer oad Dlr S H A U ( 1 5.02 ACRE IL 4.27 ACRES GTE PROVIDED FIBER—OPTIC CABLE SMACK Dealer pad 9 6' MASONRY WALL 4M ACRES < Dealer pad ro 6 3.07 ACRES 00 7 - 7 Is 7 Dealer pacVAuto Related CortwcW 3,E12 ACRES CVWD WEH ,—PROPOSED TELEPHONE 8 Dower pad/Auto Related Cc,r�n'rerdal 3,93 ACRES 6' MASONRY WALL FER C[TY REOUFEK4EW FOR ULMMATE R.O.W. Z.c - W' AVE. LAJOSCAPE PARKWAY �RC4iT IN/F11C4-IT C��ACCESS__ " __ 71� 7 EXHIBIT 7 UTILITIES TELEPHONE SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. PlanNrg/Enghwing Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture 23 J Lu WEr- Ra o EMSTING G MAScOli"slf WALL .. _ "�,�=� • .���, ,�' EXISTING G GAS MAIN 6� %�-- 6" �FUTURE SIGNAL uL T��" IFd F0R0K t 50'AVE ",10 A PARKWAY •_ • _ - - _ _._C�I.rT ACCESS Dealer pati fi ����� —sy G-`, Dealer pad 2 r � 4.4,E Aur,I � I .. 3.10 ACRES�'$ ��� �a� PROPOSED GAS MAIN `�W I 4.44 ACLS \-ACCESS TO ADAMS STREET Dealer pad 5 5.02 ACRES jt -- PLANA Dealer pad 4 4.27 ACRES �:....................:....... °� : 1� `/ SMACK 7ealrP4 0vi MASONRY uj WALL 421 ASS < ` Dealer pad 6 k 31,07 ACRES i ly �. --moo - (inoL� -1}- 7 tour Jer PsWk to fielatsd Cosrm&rcial $ 3.32 ACRES Maier pad/Auto Pe4atsd Ccmnwctal '... _ 3-93 ACRES cc CVWD WELL 'k 4 6'MASONRY WALL PROPOSED GAS MAIN �G ax.o, x m� -EXHIBIT 8 UTILITIES NATURAL GAS SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc, Plaming/Engheering Walker/Rancourt + Assoc. Arch tecture Horton/Shepardson Assoc. I _nrufacar-w% Arr+&mrfo er.m r m _• A TE EX S-nNG SOAAL y 6' MASOWY WALL -r-v t Lnrm-- SIGIMAL PER C6TY REOU69EVENT - - FOR ULTIMATE R.Q.W. .. _ -- - .. _.. ... - -� - �� _ - .. _ _ ,� yes' rAt-�-�eEr)y�•_`� _ Dealer pad I 4.03 ACRES PROPOSED ELECTRICAL E �-ACCESS TO ADAMS STREET Dealer pad 2 3.10 ACRES PLAZA d Dealer pad � "` Dever pad 4 5.02 ACRES 4..27 ACRES M b` ? EXISTING IID i 'OVERHEAD C)�! ! TRANSMISSION LINES SETBACK Dealer pad 9 6' MAY ref WALL 4-21 AGS=SM. + ! < Dealer read C j • 3.07 ACRES! • F ± p`�,, PROPOSED ELECTRICAL Dealer pad 4.04 ACRES 50' AVE_ LANDSCAPE PARKWAY — — �4;IGI-fi WRIGHT QUT ACCESS m C SS m 7 Ra&W pact/Auto Refeled (-'*wwc W y 8 r 3.82 ACRES [cater pad/Auto Related 04Nr wcW 3-43 ACRES wGV Q WELL • �, 6' MASONW WALL ;X.01 m n EXHIBIT 9 UTILITIES ELECTRICAL SPECIFIC PLAN THE CENTRE AT LA QUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. PlanNng/Eng'needng Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape ArcNtecture %%%.j�""__RELOQ&TE EYSTING, 6' MASONRY WAI I EXISTING 12" WATER 12 w RJTURE S*NAL 12" W f - Dealer pad 1 Dealer pad 2 4,03 ACRES 3JO ACRES Dealer pad 3 —J —EXISTING 18" WATER 4,04 ACRES PLAZA 'ACCESS TO ADAfAS STREET Dealer pad 5 5.02 ACRES PROPOSED -"-18" WATER w 0 Dealer pad 4 L 4.27 ACRES ... . . . . . . . . . . . . . .. . . . . ... SE -M -ACK Dealer pad 9 r''l. a 6 MASCHRY , � i i WALL_ Q 421 ACRES Utz",umar Pau U 7 00 C�Swer pad Auto Flsiaie-d Com-wcW 3Z2 ACRES Doakw pad/Auto Plekted Co,,tvrwcW 3,93 ACRES CvwD WE'L SIT= 1912 i: 6 6' MASONRY WAH PER CITY REOUIREMB4T FOR ULTIMATE P.O.W. 50' AV' LANDSCAPE ,1.t._qEMCAnaid PARKWAY RIN ' W I Fi fGhT CS JT ACCESS --� 12' W PROPOSED 18" WATER PROPOSED 12" WATER MOT EXHIBIT 10 UTILITIES WATER SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Engineering Walker/Rancourt + Assoc. Architecture Horion/Shepardson Assoc. Landscape Archliecture 98 SPECIFIC PLAN THE CENTRE AT.UA QUINTA 2.50 LAND USE 2.50.1 LAND USE PLAN The proposed plan indicates two distinct land use programs. The westerly half (43.5 acres) of the project is devoted to automobile sales and delineates sites for nine dealerships and/or auto related commercial on no more than two of the ' parcels in Phase II. These sites range from 3 acres to nearly 6 acres. These parcels will take access internally, via a public road system. The easterly portion of the site (43.5 acres) will share a signalized access at Highway 111 with the 1 auto mall. A site development alternative which appears feasible includes multiple "large box" pads, restaurants and entertainment and office uses as I depicted in Exhibit 2. The Specific Plan establishes development standards for the entire site including an integrated design for the Highway 111 and Adams Street frontages. These standards will include considerations for building siting, architecture, lighting, landscape, public art, and storm water retention. These guidelines are intended to be consistent with the La Quinta General Plan goals, policies, and objectives. The key General Plan provisions are reiterated in Appendix B. 2.50.1.1 Auto Mall The development of the auto mall portion of the project will be done via a series of freestanding dealerships and/or auto related commercial structures. A limited number of common area improvements are planned including an upgraded street design, limited common customer parking, and a vertical accent feature located in the center of a circulation roundabout. The parcelization of the auto mall anticipates nine lots which are programmed as follows: IParcel 1 Lot Size: 4.01 acres ' Facilities: Showroom/Offices: 7,000 s.f. Parts: 6,000 s.f. Service (48 stalls) 27,000 s.f ' Total 40,000 s.f. Anticipated personnel 80 Parcel 2 Lot Size: 3.08 acres Facilities: Showroom/Offices: Parts: 7,000 s.f. 4,000 s.f. Service (20 stalls) 11 400 s.f. Total 22,000 s.f. Anticipated Personnel 50 27 fJ C t r fl [1 SPECIRC PLAN THE CENTRE AT LA QUINTA Parcel 3 Lot Size: 4.00 acres Facilities: Showroom/Offices: 8,000 s.f. Parts: 4,000 s.f. Service (20 stalls) 15,600 s.f. Total 27.600 s.f. Anticipated Personnel 80 Parcel 4 Lot Size: 4.27 acres Facilities: Showroom/Offices: 10,000 s.f. Parts: 6,000 s.f. Service 20 stalls 14,000 s.f. Total 30,000 s.f. Anticipated Personnel 60 Parcel 5 Lot Size: 5.01 acres Facilities: Showroom/Offices: 8,000 s.f. Parts: 5,000 s.f. Service (20 stalls) 18,100 s.f. Total 31,100 s.f. Anticipated Personnel 80 Parcel 6 Lot Size: 3.07 acres Facilities: Showroom/Offices: 8,000 s.f. Parts: 4,000 s.f. Service 20 stalls 16,000 s.f. Total 28,000 s.f. Anticipated Personnel 80 Parcel 7 Lot Size: 3.76 acres Facilities: Showroom/Offices: 8,500 s.f. Parts: 4,800 s.f. Service (18 stalls) 18,300 s.f. Total 32,600 s.f. Anticipated Personnel 100 28 2.50.12 MIXED REGIONAL COMMERCIAL DEVELOPMENT The 43.5 acre eastern portion of the site, if developed to the full potential set forth in the City's General Plan (FAR of .35), could generate up to 580,000 square feet of commercial floor space which by City standards would require 2300 parking spaces. A development of this intensity would probably entail either a mid -rise development, multi-level parking structures, significant shared parking such as suggested under ULI guidelines, or a combination of these techniques. However, this Specific Plan limits the maximum square footage of commercial floor space to 400,000 square feet with an FAR of .25 which is far below that allowed by the General Plan. 1 Taking City of La Quinta requirements into account, including parking standards and dimensions, setbacks, open space, and storm water retention, and current commercial development patterns, this development will rely on surface parking with primarily one story and a limited amount of two story construction. Such a plan would yield over 2000 parking spaces and would support 400,000 square feet of development (FAR .25). 1 29 SPECIFIC PLAN THE CENTRE AT LA QUINTA Parcel 8 Lot Size: 3.76 acres Facilities: Showroom/Offices: 8,500 s.f. Parts: 4,800 s.f. Service (18 stalls) 18,300 s.f. Total 32,600 s.f. Anticipated Personnel 100 ' Parcel 9 Lot Size: 4.25 acres Facilities: Showroom/Offices: 8,800 s.f. Parts: Service (20 stalls) 5,600 s.f. 15,600 s.f. Total 30,000 s.f. Anticipated Personnel 80 Thus the total development anticipated in the auto mall involves approximately 43.5 acres (gross), contains 275,000 square feet of facilities (FAR = .15) and employs approximately 710 people. The maximum development for Phases I and II without further review shall be 275,000 s.f. or an FAR of .15. While it is expected that all of the sites will be developed with auto sales and related uses, the sites in Phases One and Two may develop pursuant to the allowance for uses as set forth in the Zoning Ordinance except as further delineated in Section 2.50.2.1. 2.50.12 MIXED REGIONAL COMMERCIAL DEVELOPMENT The 43.5 acre eastern portion of the site, if developed to the full potential set forth in the City's General Plan (FAR of .35), could generate up to 580,000 square feet of commercial floor space which by City standards would require 2300 parking spaces. A development of this intensity would probably entail either a mid -rise development, multi-level parking structures, significant shared parking such as suggested under ULI guidelines, or a combination of these techniques. However, this Specific Plan limits the maximum square footage of commercial floor space to 400,000 square feet with an FAR of .25 which is far below that allowed by the General Plan. 1 Taking City of La Quinta requirements into account, including parking standards and dimensions, setbacks, open space, and storm water retention, and current commercial development patterns, this development will rely on surface parking with primarily one story and a limited amount of two story construction. Such a plan would yield over 2000 parking spaces and would support 400,000 square feet of development (FAR .25). 1 29 SPECIFIC PLAN rJ4E GENTRF Ar fA UINTA Considered together with the auto mall, the total development for the entire project reaches 675,000 square feet which is an FAR of .18; only 51% of the allowable intensity set forth in the General Plan. In order to maintain views to the nearby mountain vistas, the building massing proposed in Phase III will limit the building height along Highway 111 to 35 feet and will establish minimum openings between buildings of 25 feet. fl C 11 c 1 30 t SPECIFIC THE CENTRE AT LA U1NTA 2.50.2 DEVELOPMENT STANDARDS The CR zoning development standards contained in the City of La Quinta Zoning ordinance shall be followed except where specifically modified by this Specific Plan. 2.50.2.1 PERMITTED/CONDITIONAUPROHIBITED USES The City's Zoning Ordinance delineates the range of allowed, conditionally allowable and prohibited uses for each zoning classification. A limited number of deviations from these standards are proposed within this Specific Plan. Also, due to the nature of the auto mall concept being proposed in phases one and two, a master Conditional Use Permit may be approved to cover all of the dealership sites. In addition, this Specific Plan modifies the Zoning Ordinance list of allowable and conditionally allowable uses in Phases I and II as follows: The following uses may be approved by the Planning Commission under Conditional Use Permit procedures: 1. Car Rental Agencies 2. Car Insurance Agencies 3. Car Wash (Full Service or Self Service) 5. Body Shop including Painting 4. Accessories, Retail and Installation 5. Glass Installation 6. Detailing 7. Upholstery 8. Public Auto/Recreation Vehicle Storage The following addition to the CR zone list of "Principle Uses" which would be permitted in Phase III of the Centre at La Quinta: 1. Retail stores, over 50,000 sq/ft floor area The reason for this addition is that this use fits particularly well into the concept of a mixed regional commercial center and would be controlled internally through the property management entity. The municipal concerns over such use could be controlled through the approval of the Specific Plan and additional discretionary approvals would be an unnecessary duplication of effort. 31 SPECIFIC PLAN THE CENTRE AT LA QUINTA 11 1 2.50.3 DESIGN GUIDELINES 2.50.3.1 GENERAL ARCHITECTURAL THEME The desired architectural style of the project is contemporary desert based on early California Mission, Spanish, southwest and similar themes found in La Quinta. r 2.50.3.2 ACCEPTABLE BUILDING MATERIALS A. Stucco (hand smoothed or vertical -raked textures preferred). B. Masonry: flagstone, adobe, Spanish style brick, split faced block, or fluted, split faced block. C. Wood: Exposed, heavy timber, rough sawn beams, glu-laminated beams and peeler poles with stain finish (transparent or opaque). D. Glass Block. E. Weathering Metals: Copper, iron, bronze used as accents and detail areas. 2.50.3.3 , COLORS The general color scheme shall be a range from off-white to medium earth tones. Wood shall be stained using medium to dark earth tones and complementary southwest colors (aqua, teal, terra cotta, whitewash). 2.50.3.4 ROOFS 1 Hip, gable and shed roof designs or combinations thereof consistent with the general architectural theme are acceptable and encouraged for main building masses. Acceptable roofing materials for pitched roofs include clay tile, and weathering metals. Where clay the materials are used, a multi -hued mixture of earth tones (terra cotta, buff, olive, and the like) shall be used. Although the use of clay tile and weathering metal roofs is recommended throughout, it is not specifically required for secondary or service building roofs provided other roof designs are not incompatible with the general architectural theme. 2.50.3.5 EQUIPMENT SCREENING Roof mounted mechanical equipment, ductwork and vents shall be screened from view by an architectural device consistent with the building design. 1 32 11 SPECIR PLAN n1E CENTRE AT LA QUINTA 2.50.3.6 FENCING AND WALLS Automobile service areas and service shops, shall be effectively screened from view by masonry walls of the same or complementary materials as the main building walls. 2.50.3.7 SITE LIGHTING On site lighting source for display or parking lot lighting shall be metal halide fixtures mounted on square tubular steel poles, 24 ft. in height above finish grade. Front line or perimeter poles shall be 5" x 5" square tubular steel with two 1000 watt metal halide fixtures. Interior poles shall be 5" x 5" square tubular steel with three or four 1000 watt metal halide fixtures. ' Security lighting shall be similar to display lighting except that fixtures may be reduced to 400 watts. General: All lighting shall be designed and located so as to confine direct light within the project boundaries (including landscape buffer areas located along Highway 111 and Adams Street). The lighting systems shall be designed and installed so fixtures are mounted perfectly horizontal with no tilt to the mounting. Fixtures shall be equal to "LSI " Citation Series. Pole shall be mounted to bases with anchor bolts and shall have sheet metal bolt covers. No direct burial poles shall be used. 1 33 u n SPECfF1C PLAN THE CENTRE AT LA QUINTA 2.50.4 PROJECT OPERATIONS 2.50.4.1 PROJECT OPERATIONS -AUTO MALL The auto mall operations are set forth to insure that they are fully understood to be a part of the Specific Plan. While there will be a Conditional Use Permit in place, it is the intent to delineate the elements which will comprise the operational characteristics of the auto mall to facilitate long term management of the Specific Plan and the ongoing land use of this part of the overall project 2.50.4.1.1 SITE PLAN One of the main functions of the site plans for the dealerships within the auto mall is to accommodate a great deal of vehicle storage. The design of the facilities may treat these storage areas separate from the requirements of the City dealing with automobile parking standards, including but not limited to elimination of striping, curbs, shading, and access." Vehicle storage and display may be accommodated on roofs as well as in surface facilities. 'r Customer parking areas shall comply with the requirements of the Zoning Ordinance relative to off-street parking. One City standard that does not directly apply to the auto dealerships in this project is that of an individual loading zone for each business. Due to the unique characteristics of this land use, the overall site plan has been developed to allow off-loading of vehicles within the right-of-way cross section of the internal streets (Auto Centre Drive and Auto Centre Way). The design of the cross section includes a striped, center lane that will double as a left turn lane as well as the unloading area for vehicles. The fifty foot landscape setback area along Highway 111 may incorporate vehicle displays subject to Planning Commission review and approval. Vehicle storage areas will be screened from public view by means of a solid masonry wall up to 6 feet in height and/or landscape materials including mounding. In particular, the storage areas abutting Highway 111 and Adams Street will require particular attention. The required landscape easements (50 feet and 20 feet respectively) shall be designed to enhance the screening of vehicle storage as well as service and work areas. 34 SPECIFIC PLAN THE CENTRE A T LA QUfNTA 1 2.50.4.1.2 LIGHTING ' A key tool in marketing and selling vehicles is adequate night lighting of display areas. Control of the lighting is proposed by selecting lighting fixtures that will direct light away from the perimeter property lines and toward the vehicle display ' areas. Fixtures will be "shoe box" type lights mounted on 24 foot high poles. Typically, two to four 1000 watt, metal halide lights are mounted on each pole. In front line display areas along Auto Centre Drive, Auto Centre Way, and La rQuinta Centre Drive, the poles will be spaced approximately on 40' centers. In secondary areas, the poles will be approximately 60' on center with three to four fixtures per pole. In rear storage areas, the poles will be spaced approximately 80' to 100' on center. Since the City of La Quinta has generally maintained low lighting levels, this lighting for this project shall be consistent with lower lighting levels wherever practical. All lighting will comply with the City's "Dark Sky" ordinance. 2.50.4.1.3 NOISE The operation of auto dealerships will include repair and service of vehicles. Service departments typically operate between the hours of 7:00 a.m. and 6:00 p.m., five or six days per week. It is the intent of this Specific Plan that the layout and design of the vehicle service department will be a side entrance facility. This design requirement will contain much of the noise generated by this type of activity. The layout of individual dealerships shall orient the service department openings of the perimeter sites away from the residential area to the south and west. ' A second design requirement will be the prohibition of a general usage public address system. There are a variety of communication systems available that can replace p.a. type devices for most applications. These alternatives include pagers, and personal telecommunication systems. During the life of this project, other improvements in communications should also be expected. 2.50.4.1.4 SPECIAL EVENTS The auto mall operation will include regularly scheduled special events designed to increase the flow of traffic into the center. These special events shall be limited to no more than 40 total days per year for the auto mall with no single event lasting more than 10 days. Concurrent or jointly sponsored events held on the same day shall count as a single day regardless of how many dealers 1 participate. These special events may not utilize searchlights. However, laser displays and other similar technologies or techniques may be used upon 1 35 SPECIFIC PLAN THE CENTRE ATLA QUINTA approval by the City during those special events. In no case shall any such ' lighting activity continue after 10:00 p.m. or after business hours. All special events under this entitlement shall be individually approved by the Community Development Director with the Temporary Use Permit process. 1 1 1 1 1 1 1 1 1 36 1 SPECIFIC PIAN THE CENTRE AT LA QUINTA 1 ' 2.60 CIRCULATION 2.60.1 OVERVIEW The Centre at La Quinta proposes to develop the adjacent street system in a manner consistent with the City of La Quinta General Plan Circulation Plan and also in accord with Caltrans requirements. The property is located on Highway 111, a State highway designated by the City's General Plan as a Major Arterial requiring a half street of 70 feet. The site also abuts Adams Street designated as a Primary Arterial for which the General Plan calls for a half street of 55 feet. Additional right-of-way dedication and street improvements for both streets will ' be required as a condition of approval of the project. The timing and design of improvements for Highway 111 will be coordinated with Caltrans. 2.60.2 OFF-SITE CIRCULATION SYSTEM Prior to issuance of building permits for individual Site Development Permits, applicants shall submit a Transportation Demand Management (TDM) Plan to the Public Works and Community Development Departments. The plans shall 1 37 The existing conditions around the site include partial improvements on both abutting public streets. The General Plan standards for improvements which will be required in conjunction with this project are consistent with other recent road improvements for both Highway 111 and Adams Street. The construction of the required improvements will continue the process of implementing the adopted General Plan Circulation Plan. In addition top avement, curb, gutter, median and sidewalk/bikepath improvements, traffic signals are planned at the project's main access points to both Highway 111 and Adams Street (at 47th Avenue) if warrants are met and would be installed at such time as warrants are met. In addition, the existing traffic signal at Adams and Highway 111 will be upgraded. Exhibit 11 shows the proposed cross sections for the streets affecting the project. 2.60.3 PUBLIC TRANSPORATION/TRANSPORTATION DEMAND MANAGEMENT Bus turnouts and shelters shall be provided as a part of the project's public street ' improvements pursuant to requirements of Sunline Transit, the Public Works Director and Caltrans. Prior to issuance of building permits for individual Site Development Permits, applicants shall submit a Transportation Demand Management (TDM) Plan to the Public Works and Community Development Departments. The plans shall 1 37 R/W R Am 0' P.U.E. IV LA WIN IA UtN 1 Kt UKIVC kpuvnc) Painted Median (no parking) NOT TO SCALE AU I U ULN I Kt WAT I,puonc) kwiul NUI nniy) AUTO CENTRE DRIVE (public) (with parking) NOT TO SCALE R/W P.U.E. R/W CL LA UUINIA GtNIKt LJMIVt kpuonc) Raised or Painted Median (no parking) NOT TO SCALE R/W R/W CURB k GUTTER AGGREGATE BARRIER AUAMJ JIKttl NOT TO SCALE C/L SECTION E—E STATE HIGHWAY 111 NOT TO SCALE CURB R/W CURB & GUTTER BASE EXHIBIT 11 STREET CROSS SECTIONS SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Enghewhg Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture 38 SPECIFIC PLAN THE CENTRE A T LA RUINTA address capital improvement and operational standards as set forth in the City's TDM Ordinance. Any transit related improvements required by the Sunline Transit Agency as a condition to development will not constitute compliance with the plan submittal requirements. 2.60.4 ON-SITE CIRCULATION SYSTEM The 87 acre site is generally bisected b a main north/south drive La Quinta 9 Y Y ( Centre Drive) that separates the auto mall from the mixed regional commercial site. The auto mall is further served by Auto Centre Drive and Auto Centre Way which also provides direct access from 47th Avenue. The mixed regional commercial center will develop its own internal circulation system which will be designed to interconnect with the road system established in Phases I and II with the auto mall. 1 2.60.4.1 LA QUINTA CENTRE DRIVE 1 La Quinta Centre Drive will be a roadway which starts at the landscaped entry from Highway 111 with two lanes in each direction and a total right-of-way of 88 feet. A landscaped median will divide the main drive at Highway 111. From that point to the intersection with Auto Centre Drive, there will be a painted median that will also serve as the center left turn lane. Southerly of the intersection, the road reduces to one lane in each direction with a painted center median and a total right-of-way of 60 feet. There will be no on -street parking allowed. La Quinta Centre Drive will be a dedicated public road. No individual site access will be allowed north of Auto Centre Drive with full access allowable southerly of that intersection. 2.60.4.2 AUTO CENTRE DRIVE/AUTO CENTRE WAY The internal access for the individual dealer and/or auto related commercial sites ' will be provided by dedicated public roads (Auto Centre Drive/Auto Centre Way) each with a right-of-way of 74 feet. This section, consistent with the General Plan collector street, will accommodate two travel lanes, parking on both curbs and a center left turn lane that will also be used for vehicle unloading. Auto Centre Drive also provides a direct connect to Adams Street which aligns with 47th Avenue. 2.60.4.3 MIXED REGIONAL COMMERCIAL CENTER CIRCULATION The mixed regional commercial center circulation plan is depicted on the overall site plan. However, the final circulation design will depend on the ultimate users and the configuration of buildings. The circulation design should take the loop road into consideration and access to the mixed regional commercial center 39 SPECIFIC PLAN THE CENTRE AT L4 QUWTA should align with the loop road if practical. The interior circulation system should include an identifiable "collector" road which could be either private or public depending on final design. ' The interior roadway design should take proper engineering principles into account including but not limited to adequate distance between intersecting drives and eliminating conflicts between backing vehicles and travel lanes. 1 A right-in/right-out drive to Highway 111 is proposed toward the easterly property line to allow east -bound vehicles to egress the project without having to return to La Quinta Centre Drive. This drive will also provide a second point of access from Highway 111 for those motorists who miss La Quinta Centre Drive. GCI SPECIFIC PLAN THE CENTRE AT LA Ql I NTA 2.70 LANDSCAPE 2.70.1 LANDSCAPE CONCEPT The landscape concept follows a "desert oasis" theme emphasizing water efficient materials exhibiting color and form. Parking areas in the mixed regional commercial center will feature the concept of a high canopy tree form to reduce the conflict between landscape elements and project graphics. The auto mall will use tree forms sparingly and concentrate form and color along the street frontage of each dealership and/or auto related commercial use. Most landscape areas throughout the project will be used for storm water retention. The project will feature extensive streetscapes along both Highway 111 and Adams Street. The concept of the westerly (auto mall) portion of the site will be to enclose the dealerships with a six foot walled enclosure and incorporating a graphic identification system into the required 50 foot landscape setback area. The easterly (mixed regional commercial center) plan will incorporate the landscape buffer into the overall plan. No wall will be required east of the main entry with the exception of the overall entry treatment including possible project signage. The City of La Quinta is developing a streetscape program for Highway 111. It is the intent of this Specific Plan to complement that effort by incorporating design principles into the guidelines for the project. One area that the Specific Plan will have to deviate from the streetscape program will be the tree palette. The Highway 111 streetscape concept uses mostly flowering trees which are not appropriate in the circumstance of auto dealerships. Trees of similar shape and size will be used; however, flowering trees will not be required along the auto mall portion of the Highway 111 frontage. 2.70.2 LANDSCAPE DEVELOPMENT STANDARDS The Centre at La Quinta will meet the minimum standards for landscape as set forth in the Zoning Ordinance. 41 n u fJ SPECIFIC PLAN THE CENTRE AT _LAUC? INTA 2.70.3 LANDSCAPE PALLETTE Landscape materials selected for detailed landscape plans shall be chosen from the following materials: MASTER PLANT LIST- Exhibit 12 TREES ACACIA SMALII SWEET ACACIA ACACIA STENOPHYLLA SHOESTRING ACACIA CERCIDIUM FLORIDUM BLUE PALO VERDE CERDIDIUM PRAECOX SONORAN PALO VERDE GEIJERA PARVIFOLIA AUSTRALIA WILLOW LYSILOMA THORNBERI FEATHER BUSH SOPHORA SECUNDIFLORA TEXAS MOUNTAIN LAUREL PALMS CHAMAEROPS HUMILIS MEDITERRANEAN FAN PALM WASHINGTONIA FILIFERA CALIFORNIA FAN PALM WASHINGTONIA ROBUSTA MEXICAN FAN PALM SHRUBS CAESALPINIA PULCHERRIMA RED BIRD OF PARADISE CASSIA SPECIES CASSIA ENCELIA FARINOSA BRITTLE BUSH JUSTICIA SPICIGERA MEXICAN HONEYSUCKLE LEUCOPHYLLUM C. SPECIES TEXAS RANGER NERIUM OLEANDER'PETITE PINK' DWARF OLEANDER NOLINA PARRYI DWARF MEXICAN GRASS TREE RAPHIOLEPIS (.'SPECIES' INDIA HAWTHORN SALVIA G. 'SIERRA LINDA' SAGE SIMMONDSIA CHINENSIS JOJOBA THEVETIA PERUVIANA YELLOW OLEANDER XYLOSMA CONGESTUM'COMPACTA' DWARF XYLOSMA GROUNDCOVER ANNUAL COLOR SEASONAL FLOWERS ACACIA R. 'DESERT CARPET' TRAILING ACACIA BACCHARIS CENTENNIAL BACCHARIS DALEA GREGGII PROSTRATE INDIGO BUSH LANTANA MONTEVEDENSIS PURPLE PROSTRATE LANTANA LANTANA M. 'GOLD SPOT' YELLOW PROSTRATE LANTANA OENOTHERA BERLANDIERI MEXICAN PRIMROSE ROSMARINUS O. 'LOCKWOOD FOREST' DWARF ROSEMARY SANTOLINA VIRENS GREEN SANTOLINA 42 u SPECIFIC PLAN THE CENTRE AT LA QUINTA VERBENA RIGIDA PALM SPRINGS'GOLD' WILDFLOWERS DESERT WILDFLOWER MIXTURE 2.M4 LANDSCAPE MAINTENANCE VERBENA GRAVEL TAILINGS CALIFORNIA POPPIES, VERBENA, ETC. A landscape maintenance handbook shall be established to develop standard maintenance practices for the overall project. Of particular concern, is to allow tree forms to fully develop in the parking lot areas in order to achieve the required percentage of shading as set forth in the Zoning Ordinance. Landscaping maintenance for the auto mall portion of the project shall be under a single maintenance contract managed by the Property Owners Association. Similarly, the landscape for the mixed regional commercial center shall also be under a single maintenance contract managed by the center or by the Property Owners Association in the event that multiple ownership exists. n t 1 43 SPECIFIC PLAN THE CENTRE AT LA QUINTA 2.80 SIGNAGE 2.80.1 SIGNAGE CONCEPT Comprehensive sign plans shall be in place for each Phase of developoent prior to the issuance of building permits for that phase. The main principle of the comprehensive sign plan shall be compliance with the Sign Ordinance portion of the La Quinta Zoning Ordinance. Monument signs shall conform to the City of La Quinta standard of 8 feet maximum height except for the primary project monuments which may be 12 feet high as shown in Exhibit 18. 2.80.1.1 SIGNAGE CONCEPT -AUTO MALL Due to its unique retailing and land use concept, the auto mall has turned inward, away from Highway 111 to equalize the location factor across the site. Although only three of the dealerships have technical "frontage" on Highway 111, each dealer will be afforded one graphic identification sign in the landscape setback area along Highway 111. In addition, overall center identification signs will be utilized along Highway 111; one monument sign west of the main entry and one near the corner of Adams Street and Highway 111. At the entrance on Adams Street an identification sign may be allowed providing identification to both the auto mall as well as the mixed regional commercial center. Exhibit 18 shows the conceptual monument signs proposed for Highway 111 and Adams Street. Once inside the auto mall, each of the dealers will be allowed the following signage: 1. One ground mounted "Dealership Identification" sign per franchise not to exceed 40 sq. ft. per face. This sign is primarily for manufacturer's identification. 2. One wall mounted "Dealership Identification" sign with .24" maximum height letters. Letters shall be channel can, plex-faced, internally illuminated. 3. One secondary wall or fascia mounted sign for each department (used cars, service, parts, and body shop). Sign shall be of appropriate size to be seen from the internal loop street and shall be sized to fit the architectural element on which it is located. 4. Directional signs as necessary as approved by the Director of Community Development. Exhibit 19 depicts the sign locations and design concept for the interior Identification signs for the auto dealers. 44 SPECIFIC PLAN _ _ THE CENTRE ATL4 QUINTA I 2.80.1.2 SIGNAGE -MIXED REGIONAL COMMERCIAL CENTER The appropriate signage for the ultimate user(s) of this portion of the project will only be determined upon development of a detailed site and use plan for the site. The signage concept shall include a single -sign allowance per main building entrance. Alternative locations may be considered based on the most effective use of graphic identification. Multi -tenant buildings shall integrate a concept for graphics into the architectural scheme which shall become the basis for the comprehensive sign plan for the complex. Freestanding signs may identify the building only; not individual tenants. Single user, freestanding buildings may use freestanding, monument signage. The mixed regional commercial center shall be allowed two complex identification signs; one east of the main entry on Highway 111 and a second sign near the easterly access point. The center may utilize signage at major access points off La Quinta Centre Drive. Major tenants (GLA over 50,000 s.f) may be identified on the complex signs. Exhibits 17 and 18 depict the sign locations and design concept for the identification signs for the retail center portion. 45 SECTION -I HIGHWAY 111 PARKWAY 1 /B"z V. 0" r�� HORTON SHEPARDSON ASSOCIATES IA.OKAK AMMICnAl EXHIBIT 13 LANDSCAPE HWY 111 X -SECT SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/6xjhwing Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Arctvtecture 46- rA-er� WA 1. - W f CAF GoW MN* (01a locl c-0. Wli'7r-, 51DEWAt K- G�NG�T� C`I�wP-SND AUTO DEALERS L,,AMJ HIGHWAY 111 PLAN — HIGHWAY 111 PARKWAY 151=205"01115 r2 x 10GI WAa 1 - 12i�c� &-d o. C' tAWN II~ HORTON SHEPARDSON ASSOCIATES #ft04TKrM EXHIBIT 14 LANDSCAPE HWY 111 CONCEPT SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Eng'neering Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape ArcMecture 47 IwrA PLAN -ADAMS PARKWAY *1"=zo3"05, WIN LAWN sECT1C2IV-ADAMS PARKWAY 1/455=13-0" � 1 tir- ,AL)Tc PE�AL_Vf, HORTON SHEPARDSON ASSOCIATES M(>.TKnW EXHIBIT 15 LANDSCAPE ADAMS STREET SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planting/BVineering Walker/Rancourt + Assoc. ArcMecture Horton/Shepardson Assoc. Landscape Arct*ecture 48 J PLAN - AUTO CENTRE DRIVE w/ WEE4 U.1 'I, v Ni HORTON !!�. ! !! VLS SHEPARDSON 1 =20 -O ASSOCIATES L41 oeu+t iA74 nCru1E 0 — — Jnr � W i Ma r •R 0 W Ws � � W— M i � w 1— A � KIM f WEW — . — r ■ — ■ — ■ ■ EXHIBIT 16 LANDSCAPE AUTO CENTRE SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/BVheering Walker/Ranoourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture r i1 -61 mASO�40RY WALL q ONAL RIGHWAY FUTURE WVUL ub, QDJ- f A) Dealer pad 1 4,03 ACRES z \--ACCESS TO ADAW SITEET Dealer pad 5 5.02 TS 1 r ji ey- w SE7BACK VVAS OWY WALL Dealer pad 6 3.07 ACRES Dealer pad 2 3.10 ACRES Dealer pad 3 4.04 ACFES FILAZA 7 De,&ter piLd/Aryr'y Auto Umo 3.82 ACRES Dealer pad 4 4.27 ACFC-8 Deafer pad 9 4.21 ACRES a r>,-jLjer pad/AndWy Auto U066 3.93 ACRES 62 MASVNRY WALL F,ER crry REOUIREMWr FOR Ul-1114ATE FLO.W. -:0-1 Arry 6' 11AX 53` AVE. L*MSCMIE: PARKWAY R W/RK-+fT FA NQ PARKlhr.x 1932.25 PARKIWA 330-01 EXHIBIT 17 SIGNAGE PLAN SPECIFIC PLAN THE CENTRE AT LA OUINTA SIGN PROGRAM KA) - AUTO CENTER MONUMENT \C/ REGIONAL CENTER MONUMEN' COMBINED AUTO/REGIONAL MONUMENT DEALER ID MONUMENT• STAMKO DEVELOPMENT mainiero, Smith and Assoc. FlanNng/Engheering Walker/Rancourt + Assoc. Architecture Horton/Shepardson Assoc. Landscape Architecture 50 1 1 1 1 1 L 1 1 1 I 1 1 1 1 1 N poo �•-s DEALER SIGNAGE 3 /8"=1'-®" , .A / The Centre at La Quinta ENTRY MONUMENT WY *111 ENTRY MONUMENT 47 TH -AV E 3/8"=�'-o" Mri r, O AL. F,0C-K PrC.lOOT Lam,, o n ,yti. y po 21. -Abe lilt JL — } HORTON SHEPARDSON ASSOCIATES EXHIBIT 18 SIGNAGE ONUMENT SIGN SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. f Planning/evheering ! Walker/Rancourt + Assoc. ArcMedure Horton/Shewdson Assoc. %ar4ac a AreMacture II 51 1 1 1 1 1 1 1 1 L 1 1 1 f 1 1 1 1 1 ENTRY MONUMENT 47 TH -AVE �A-PJgAL, pooh DEALER SIGNAGE 1 The Centreat IMP! ENTRY MONUMENT SRT, I OIAI-- Flc0}c praAO T L06--C>-x 0 t? o E a :o m CJ oe c ARA KI HORTON SHEPARDSON ASSOCIATES PADOWIM EXHIBIT 18 SIGNAGE ONUMENT SIGN SPECIFIC PLAN THE CENTRE AT LA QUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Eng'neering Walker/Rancourt + Assoc. ArdAecture Horton/Shepardson Assoc. Landscape ArcNtecture 51 ,� SOUTH ELEVATION BUILDING IDENTIFICATION s MONUMENT IDENTIFICATION EXHIBIT 19 SIGNAGE BUILDING SPECIFIC PLAN THE CENTRE AT LA OUINTA STAMKO DEVELOPMENT Mainiero, Smith and Assoc. Planning/Eng'neering Walker/Rancourt + Assoc. ArcMect re Horton/Shepardson Assoc. Landscape ArcMecture 52 0 SPFCIFIC PLAN THE CENTRE AT LA t. UINi A APPENDIX A CONDITIONS OF APPROVAL (To be Added) SPECIFIC PLAN THE CENTRE AT LA QUINTA APPENDIX B APPLICABLE GENERAL PLAN POLICIES APPLICABLE GENERAL PLAN POLICIES The General Plan of the City of La Quinta was adopted in 1992 and included the Goals, Objectives and Policies that were deemed necessary to properly implement the plan. The key policies which come into play with the development of the subject property are as follows: 2.0 LAND USE ELEMENT 2-2.1.1 "The General Plan shall utilize the building floor area to site area ratio (F.A.R.) as the appropriate standard for commercial land use intensity. F.A.R. shall be defined as the gross floor area of a building divided by the net area of the commercial parcel of land. Net area is the total area of a site minus the area dedicated as public street right-of-way." Table LU -4 further defines the F.A.R. in the M/RC category as a maximum of 0.35 with a building height of four stories. Such use is limited to the Highway 111 corridor. 2-3.1.1 "The M/RC category shall provide areas for businesses serving the entire region with a trade area typically exceeding 100,000 people. Businesses allowed to locate the M/RC areas shall include major retail commercial tenants associated with a regional mall, off-price retail outlet and/or 'power center.' Other businesses permitted in the M/RC category include regional service centers, research and development facilities, major community facilities and/or major medical -related facilities. overnight commercial lodging uses, entertainment uses, as well as automobile uses of a regional nature, may also be included." 2-3.1.9 "A specific plan must be approved prior to any land division or other development approval action of projects in the M/RC areas." 2-3.1.10 "Project approvals and redevelopment agreements for projects in M/RC areas shall stipulate phasing of construction and responsibility for public facility improvements." 2-3.1.11 Design of projects in M/RC areas shall include appropriate standards to establish adequate buffers and land use compatibility between commercial and residential uses both within and the mixed-use project and with surrounding property." 2.3.12 , "The City shall require the development and integration of 'Employment Support Services' in the M/RC Category including such uses as childcare, occupational health, fitness facilities, etc." 3.0 CIRCULATION ELEMENT 3-2.1.7 "Development projects along Highway 111 shall dedicate right-of-way as specified by Caltrans (California Department of Transportation) to provide a maximum right-of-way of 172 feet, or as needed by Caltrans. The City will coordinate with Caltrans and the Coachella Valley Association of Governments (CVAG) to identify regional options for relieving the growth of future traffic demands in the Highway 111 Corridor." 3-3.1.1 "Access to all major and primary arterials shall be restricted to intersection locations and other approved points of ingress and egress." 3-3.1.3 "The City shall institute street access guidelines consistent with the functional roadway classifications. These shall be applied, where feasible, to all new developments. The following guidelines shall be sued to define appropriate access: a). The City shall restrict individual driveway access to Major and Primary Arterials wherever possible. b). Access to Major and Primary Arterials shall be limited through the use of medians and access controls to maintain street capacity. c). When permitted, access along arterial and collector streets shall be located a minimum of 250 feet from the ends of the curb returns." 3-3.1.4 "In order to enhance and protect the capacity and safety of the circulation system and reduce potential traffic conflicts, the City shall require the consolidation of driveway access points along roadways classified as collector and arterial." 3-4.1.1 "Special roadway image corridors and City gateways which evoke a unique identity and character throughout the City shall be designated on Figure CIR-5, Streetscape Image Policy Diagram." 3-4.1.2 "Primary image corridors shall be defined as streets in the roadway network which are the major urban design statements of the City. Primary image corridors shall consist of boulevard streets with raised, landscaped medians and heavily landscaped areas within and contiguous to the street right-of-way. Primary image corridors shall include landscape themes which are reminiscent of La Quinta's agricultural past and desert environment. Primary image corridors may include vertical elements such as palm trees complemented with a shade -producing understory of canopy trees, such as indigenous, drought tolerant desert species. More water intensive understory canopy trees, such as various citrus species, should be used sparingly in does at key locations as highlights and reminders of past agricultural activities. Ground plane landscape materials should evoke a lush image through the use of drought tolerant, low maintenance plant species. Turf should be used in a manner consistent with citrus trees --sparingly and in high visibility locations. Primary image corridors shall include street traffic signals, street lighting systems, street furniture, bus shelters, street name signs, and noise berms/barriers which are designed in a coordinated and consistent theme unique to La Quinta. At key intersections, primary image corridors shall include treatments which may include special roadway paving, hardscape/screen wall arrangements and displays of public art." 3-4.1.3 "Primary image corridors shall include the following roadways: Highway 111." 3-4.1.4 "Secondary image corridors shall be defined as streets in the roadway network which are the secondary urban design statements of the City. Secondary image corridors shall consist of streets with raised, landscaped medians and landscaped areas within and contiguous to the street right-of-way. Secondary image corridors shall be consistent with primary image corridors relative to similar landscape materials, street traffic signals, street lighting systems, street furniture, bus shelters and street name signs. However, secondary image corridors shall emphasize the use of lower profile indigenous canopy trees, accentuated with the use of citrus trees in various nodes. The use of taller, vertical landscape elements shall be de-emphasized and shall occur in nodes, primarily at street intersections." 3-4.1.5 "Secondary image corridors shall include the following roadways: Adams Street (south of the Coachella Valley Stormwater Channel)" 3-4.1.10 "Along primary, secondary, and agrarian image corridors the City shall establish appropriate building height limits to ensure a low density character and appearance." 3-4.1.11 "Landscaped setbacks are necessary to ensure a high quality and attractive appearance on major streets. Setbacks for walls, buildings and parking areas may vary, if properly designed, but shall generally be as follows: • Highway 111 - 50 feet • Other Major Arterials - 20 feet Landscaping within these setback areas shall be consistent with the appropriate image corridor designation, if applicable." 3-4.1.17 "The City's streetscape quality shall be improved by undergrounding of utilities wherever possible." 3-4.1.18 "Prevention of visual blight shall be enhanced by the administration of a comprehensive sign ordinance." 3-5.1.5 "The City shall coordinate with Sunline Transit to establish transit stops adjacent to medical facilities, senior citizen facilities, major areas of employment, shopping centers and parks." ENVIRONMENTAL CONSERVATION ELEMENT 6-1.1.2 "The City shall utilize street corridors to provide scenic vistas go of the Coral Reef and Santa Rosa Mountains. Landscaped setbacks along streets shall be required pursuant to Policy 3-4.1.11 in the Circulation Element of the General Plan. The setbacks are as follows: Highway 111 - 50 feet; Other Major Arterials - 20 feet. AIR QUALITY ELEMENT 9-2.1.1 "in accordance with the California Environmental Quality Act (CEQA), the City shall require all proposed developments to evaluate the air quality impacts of the proposed use. The applicant shall submit an air quality analysis if the project meets one of the following threshold criteria of significance for air quality or threshold levels for land uses identified in the most recent version of the South Coast Air Quality Management District's Air Quality Handbook for preparing Environmental Impact Reports. Air quality analyses for new development shall locate sensitive receptors near the project and assess probable exposure to the project's emissions. If the project will have a significant impact on air quality, the analysis must propose suitable mitigation measures as identified in the South Coast Air Quality Management District's Air Quality Handbook for preparing Environmental Impact Reports." 9-8.2.5 "The City shall administer the provisions of the existing Outdoor Illumination Ordinance (Dark Sky Ordinance) to help limit night time energy consumption from lighting."